Flameproof Alternators

Size: px
Start display at page:

Download "Flameproof Alternators"

Transcription

1 Overview Standard automotive type alternators are a continuous potential source of ignition when operated in hazardous atmospheres where combustible concentrations of gas, vapor or dusts may exist. To overcome this, Chalwyn offer a range of ATEX approved flameproof alternators designed specifically to mount on diesel engines as direct replacements for standard alternators. Features and Benefits ATEX and IECEx Certified for Hazardous Zones 1 or 2 Speed signal output for overspeed shutdown Compact high performance design Certified cable gland included (side or rear mounted) Wide choice of optional pulleys Suitable for offshore conditions Applications For use in hazardous areas classified as Zone 1, Gas Group IIB, T4 and Dust Group IIIC, T135 Suitable for local ambient temperature range -30 C to +55 C Designed as a belt driven diesel engine mounted alternator page 1

2 Specifications Standard materials Enclosure Aluminum Fan, fan discs, pulleys Carbon steel Cowls Copper Excitation ASX-200, -201, -300, -301, -400, -401 Externally excited ASX-310 Self-excited Area Classification Zone 1, Group IIB Temperature Class T4 Ambient ASX-200, -201, -300, C to 55 C (-22 F to 131 F) temperature range ASX-400, C to 50 C (-22 F to 122 F) Voltage ASX-300, -301, -310, -400, V ASX-200, V Weight (estimated) Product Weight ASX-2XX, -3XX 7.2 kg (161.1 lbs) 12.9 kg (28.4 lbs) Shipping Weight ASX-2XX, -3XX 8 kg (17.5 lbs) 16.1 kg (36 lbs) Current ASX-200, -201, -400, V ASX-300, -301, V Certifications Ingress protection IP66 Equipment ASX-2XX, -3XX SIRA 99ATEX1127X Classification SIRA 07ATEX1171X Description Twelve pole rotating field coil type alternators are designed and approved as Category 2G/D equipment. An example of alternator markings is shown in Figure 1. A number of alternative single or multigroove pulleys are available. Contact factory for up to date details of the standard range. Special pulleys are also available to meet customer design requirements. How to Order DIESEL PROTECTION SYSTEMS by AMOT ROPER INDUSTRIES LTD BURY ST EDMUNDS, IP33 3SZ, UK 0518 SIRA 99ATEX1127 TYPE ASX-300 SERIAL No. XXXXX Ex IIB T4 Gb (Tamb= -30 C TO 55 C) Ex IIIC T135 Db IP66 II 2 G/D TMAX 125 C OUTPUT 28V 25A MAX DO NOT OPEN WHEN EXPLOSIVE GAS AND/OR DUST ATMOSPHERE IS PRESENT Figure 1 Model ASX - A B C A Output 2 14V 50A 3 28V 25A 4 28V 50A B Excitation 0 Externally Excited 1 Self-exciting C Cable Gland 0 Side Entry* 1 Rear Entry** * If side entry option is selected, the rear cover of alternator may be rotated to various positions -see dimension drawings. ** Four (4) rear entry gland positions are possible by unbolting and rotating the removable rear cover. page 2

3 Pulley Selection Flameproof Alternators Using the table below, select the pulley profle, appropriate width and drive diameter. Take into account the alternator speed range when selecting the diameter of the pulley. When fitting a pulley use an 8mm hexagonal Allen drive in the rotor hole and tighten the nut supplied to 60 NM (44 lb ft) torque. If a non-chalwyn pulley is to be fitted, please forward design details to local factory office. Pulley Profile Belt Width Drive Diameter (mm) Pulley Model No. SPA (Small) 1/2 / 13mm 55 ASX-546 SPA (Medium) 1/2 / 13mm 71 ASX-549 SPA (Large) 1/2 / 13mm 80 ASX-574 SPB (Small) 5/8 / 16mm 66 ASX-539 SPB (Medium) 5/8 / 16mm 71 ASX-548 SPB (Large) 5/8 / 16mm 90 ASX Groove Poly-V DIN 6-PK 56 ASX Groove Poly-V DIN 6-PK 66 ASX-556 Twin Groove SPB 2 5/8 / 16mm TBA ASX-557* Twin Groove SPC 2 3/4 / 19mm 80 ASX-573* 8 Groove Poly-V DIN 8-PK 67 ASX-570* 10 Groove Poly-V DIN 10-PK 71 ASX-571* 12 Groove Poly-V DIN 12-PK 75 ASX-572* Speed calculation formula * (fits ASX-400/401) Crankshaft pulley diameter (mm) X Engine Speed (rpm) = Alternator Speed (rpm) Alternator pulley drive diameter (mm) Target Alternator Speeds Model Engine Speed (rpm) Alternator Speed (rpm) ASX-2XX, -3XX Special Notes Fixed Variable Low idle Fixed Variable Low idle a. The cable entry point exceeds 70 C under rated conditions, therefore, in accordance with IEC/EN Clause 16.6, suitably rated cable shall be selected for installation. b. The output voltage from the alternator is controlled by an internal regulator. It is recommended however that over voltage protection is fitted to any circuit supplied by the alternator in which one or more components could become a potential source of ignition should over voltage occur. c. To maintain full compliance with hazardous area and EMC requirements ensure: 1. The external earthing point of the alternator and any armored/screened cable are properly bonded to the engine/engine frame. 2. Any connected electrical equipment is engineered to the requisite standard. page 3

4 Special Notes - continued Flameproof Alternators d. The alternators must not be connected to any process temperatures which exceed the T Class (135 C), ambient temperatures must be observed. e. The cooling fan shall be suitably enclosed with a fan hood capable of resistance to impact in accordance with of IEC/EN f. Dust applications - parts of the enclosure may be non-conducting and may generate an ignition - capable level of electro static charge under certain extreme conditions. The user should ensure that the equipment is not installed in a location where it may be subjected to external M16 M16 THREAD THREAD conditions (such as high pressure steam), which might cause a build up of electrostatic charge on non-conducting surfaces. (KEY) (KEY) Dimensions ASX-200, ASX-300, ASX R11.25 R ENSURE PULLEY ENSURE IS DESIGNED PULLEY IS DESIGNED SO THAT ON TIGHTENING SO THAT ON THE TIGHTENING THE NUT, THE PULLEY NUT, CLAMPS THE PULLEY THE CLAMPS THE FAN PLATE & FAN PLATE IN POSITION. & FAN IN POSITION (KEY HEIGHT) (KEY HEIGHT) Ø17.00 (SHAFT) Ø17.00 (SHAFT) Ø Ø Ø10.50 Ø10.50 ASX-400 ASX-401 page 4

5 Americas Asia Pacific Europe, Middle East and Africa AMOT - USA Tel +1 (281) Fax +1 (713) sales@amot.com Roda Deaco - Canada Tel +1 (780) Fax +1 (780) info@rodadeaco.com AMOT - China Tel Fax shanghai@amot.com AMOT - Singapore Tel Fax singapore@amot.com AMOT - England Tel +44 (0) Fax +44 (0) info@amot.com AMOT - Germany Tel +49 (0) Fax +49 (0) germany@amot.com Chalwyn s quality management system is approved by LRQA. page 5

Self-Exciting Flameproof Alternator

Self-Exciting Flameproof Alternator Self-Exciting Flameproof Alternator Model ASX-310 Application l For use use in in hazardous hazardous areas areas classified classified as as Zone 1, For Zone 1, Gas Group IIB, T4 and Dust Group IIIC,

More information

Flameproof Alternator

Flameproof Alternator Flameproof Alternator Models ASX-200, ASX 201 ASX-300, ASX 301 Application For use in hazardous areas classified as Zone 1, Group IIB, T4 Suitable for local ambient temperature range -30 C to +50 C Designed

More information

Flameproof Alternator

Flameproof Alternator Flameproof Alternator Models ASX-400, ASX-401 Application l For use in hazardous areas classified as Zone 1, Group IIB, T4 l Suitable for local ambient temperature range -30 C to +50 C l Designed as a

More information

Flameproof Alternator

Flameproof Alternator Flameproof Alternator Installation, Operation and Maintenance Alternator Types ASX-400 ASX-401 CE242 (6) ASX_0210 DESCRIPTION Twelve pole rotating field coil type externally excited alternators designed

More information

SVX-Series Diesel Engine Shut Down Valves (Solenoid Latched Types with Manual Start Override/Emergency Stop)

SVX-Series Diesel Engine Shut Down Valves (Solenoid Latched Types with Manual Start Override/Emergency Stop) SVX-Series Diesel Engine Shut Down Valves (Solenoid Latched Types with Manual Start Override/Emergency Stop) Selection, Application and Maintenance Valve Numbers SVX-340 SVX-350 SVX-341 SVX-351 SVX-540

More information

Solenoid Actuated Diesel Engine Air Shut Down Valves

Solenoid Actuated Diesel Engine Air Shut Down Valves SVX-Series Solenoid Actuated Diesel Engine Air Shut Down Valves (Energised to Run, Hazardous Area Types without Manual Override) Selection, Application and Maintenance DS-SVX320-830-SolenoidValves-CE239-0712-rev1

More information

Diesel Engine Shutdown Valves

Diesel Engine Shutdown Valves Diesel Engine Shutdown Valves Models MVX-301, MVX-302, MVX-303 MVX-501, MVX-502, MVX-503 MVX-801, MVX-802, MVX-803 Cable Operated Closure/Integral Reset Lever Types by AMOT DS-HVX301-803-ShutdownValve-CE217-0712-rev1

More information

Air Intake Shut-off Valve

Air Intake Shut-off Valve Overview Diesel runaway is a constant problem, injuring personnel and causing severe damage to equipment every year. A diesel engine will runaway and self destruct on hydrocarbon vapors, even if the engine

More information

MVX-Series Diesel Engine Air Shut Down Valves

MVX-Series Diesel Engine Air Shut Down Valves MVX-Series Diesel Engine Air Shut Down Valves (Cable operated closure/integral reset lever types) Selection, Application and Maintenance SPECIAL VALVE MVX-304 This is a special version of valve type MVX-303

More information

HVX-Series Diesel Engine Shut Down Valves (Oil Pressure Latched Types with Manual Start Override/Emergency Stop)

HVX-Series Diesel Engine Shut Down Valves (Oil Pressure Latched Types with Manual Start Override/Emergency Stop) HVX-Series Diesel Engine Shut Down Valves (Oil Pressure Latched Types with Manual Start Override/Emergency Stop) Selection, Application and Maintenance Valve Numbers HVX-300 HVX-500 DESCRIPTION Based on

More information

Diesel Engine Shutdown Valve

Diesel Engine Shutdown Valve Diesel Engine Shutdown Valve Models PVX-300, 301 PVX-500, 501 PVX-800, 801 (Pneumatically Actuated) Typical Applications PVX-300, PVX-500, PVX-800 Failsafe application to meet EU ATEX 94/9/EC defined hazardous

More information

SVX-Series Solenoid Actuated Diesel Air Shut Down Valves

SVX-Series Solenoid Actuated Diesel Air Shut Down Valves SVX-Series Solenoid Actuated Diesel Air Shut Down Valves (Energised to stop types) Selection, Application and Maintenance Special Valve SVX-592 This valve is a special version of SVX-590. The general installation

More information

Diesel Engine Safety Solutions. Automatic Engine Overspeed Shut Down Valves - D Series

Diesel Engine Safety Solutions. Automatic Engine Overspeed Shut Down Valves - D Series Diesel Engine Safety Solutions Automatic Engine Overspeed Shut Down Valves - D Series Automatic Engine Overspeed Shut Down Valves Applications Cranes Fork Lift Trucks Aerial Platforms Air Compressors Water

More information

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx) INSTRUCTION MANUAL (ATEX / IECEx) BExBG10D-P and BExBG15D-P Flameproof Xenon Beacons For use in Flammable Gas and Dust Atmospheres BExBG10D-P / BExBG15D-P 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE

More information

World class manufacturer of safety solutions SYSTEM SELECTION GUIDE. Safety solutions for vehicles and machines working in petrochemical plants

World class manufacturer of safety solutions SYSTEM SELECTION GUIDE. Safety solutions for vehicles and machines working in petrochemical plants World class manufacturer of safety solutions SYSTEM SELECTION GUIDE Safety solutions for vehicles and machines working in petrochemical plants 1 Diesel Engine Safety Solutions Chalwyn: Over 35 years of

More information

System Selection Guide

System Selection Guide World class manufacturer of safety solutions System Selection Guide Safety solutions for vehicles and machines working in petrochemical plants SYSTEM 1 12V EURO 5/6 Road Vehicles Page 2 SYSTEM 2 24V Trucks

More information

D-Series Automatic Engine Overspeed Shut Down Valves (Bendix Types)

D-Series Automatic Engine Overspeed Shut Down Valves (Bendix Types) D-Series Automatic Engine Overspeed Shut Down Valves (Bendix Types) Selection, Application and Maintenance Valve Numbers D45 D51 D57 D64 D70 D80 CE204 (12) D series DESCRIPTION A range of spring loaded

More information

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx) INSTRUCTION MANUAL (ATEX / IECEx) BExBGL2D LED BEACON For use in Flammable Gas and Dust Atmospheres BExBGL2D 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN ENERGIZED POTENTIAL

More information

SELECTION, APPLICATION AND MAINTENANCE

SELECTION, APPLICATION AND MAINTENANCE DIESEL PROTECTION SYSTEMS Automatic Diesel Engine Shut Down System and Self Exciting Flameproof Alternator for Hazardous Area Applications SELECTION, APPLICATION AND MAINTENANCE Series 110 Series 111 SYSTEM

More information

Flameproof - Group IIB or IIB + H 2 Carbon steel - DE8BC series. Painted steel. -40 C or -20 C C or +50 C or +60 C

Flameproof - Group IIB or IIB + H 2 Carbon steel - DE8BC series. Painted steel. -40 C or -20 C C or +50 C or +60 C Enclosures Flameproof - Group IIB or IIB + 2 Carbon steel - DE8BC series The flameproof control cabinets DE8BC are designed for the control, automation, distribution boards, motor starters or any other

More information

Pilot Operated 2-Way Gas Valves

Pilot Operated 2-Way Gas Valves Pilot Operated 2-Way Gas Valves Model 2180ED - ductile iron Model 2180ES - cast steel Overview AMOT Model 2180 valves will shut off the fuel gas and vent the manifold when used on an internal combustion

More information

Diesel Engine Air Intake Shutoff Valves

Diesel Engine Air Intake Shutoff Valves Diesel Engine Air Intake Shutoff Valves Model RDS2 Swing Gate Valve Overview If flammable gas or vapor is present in the atmosphere surrounding a diesel engine, it can be ingested into the engine and become

More information

Optimise your temperature control

Optimise your temperature control Optimise your temperature control Fast response, low pressure drop valves for tighter temperature control 3-Way Temperature Control Valve - Model G Overview Introducing the Model G 3-Way Temperature Control

More information

SVX-Series Solenoid Actuated Diesel Engine Air Shut Down Valves (Energised to Run, Hazardous Area Types without Manual Override)

SVX-Series Solenoid Actuated Diesel Engine Air Shut Down Valves (Energised to Run, Hazardous Area Types without Manual Override) SVX-Series Solenoid Actuated Diesel Engine Air Shut Down Valves (Energised to Run, Hazardous Area Types without Manual Override) Selection, Application and Maintenance Valve Numbers SVX-320 SVX-330 SVX-520

More information

Pressure and Temperature Switches

Pressure and Temperature Switches Pressure and Temperature Switches Model 4140 Typical applications Suitable for industrial and marine applications Providing protection and safety of: --Diesel engines --Compressors --Pumps --Transmissions

More information

Intake Air Shut-off Valve

Intake Air Shut-off Valve Intake Air Shut-off Valve Model 4261M Overview Diesel run-away is a potential problem that can cause damage to equipment. A diesel engine can run away and self destruct on hydrocarbon vapors, even if the

More information

2-Way Temperature Sensing Valves

2-Way Temperature Sensing Valves 2-Way Temperature Sensing Valves Models 2230 and 4430 Overview Model 2230/4430 is a normally-closed, 2-way valve which is opened by increasing temperature of engine cooling water, lubricating oil, high

More information

RODADEACO. Diesel Engine Air Intake Shutoff Valves. Model RDB3 Compact Butterfly Valve. by AMOT. Overview. Typical Applications

RODADEACO. Diesel Engine Air Intake Shutoff Valves. Model RDB3 Compact Butterfly Valve. by AMOT. Overview. Typical Applications Diesel Engine Air Intake Shutoff Valves Model RDB3 Compact Butterfly Valve Overview If flammable gas or vapor is present in the atmosphere surrounding a diesel engine, it can be ingested into the engine

More information

Solutions Ex d IIB+H2, Aluminum and Stainless Steel

Solutions Ex d IIB+H2, Aluminum and Stainless Steel Features Assembly examples Enclosures manufactured from copper-free aluminum or AISI 316L stainless steel Suitable for operation in Zones 1, 2, 21 and 22 Certified Ex d IIB+H2 and Ex tb More than 40 enclosure

More information

ALUMINIUM AND STAINLESS STEEL ENCLOSURES - EJB... SERIES

ALUMINIUM AND STAINLESS STEEL ENCLOSURES - EJB... SERIES Ex d IIB+H 2 ALUMINIUM AND STAINLESS STEEL ENCLOSURES - EJB... SERIES ALUMINIUM ENCLOSURES STAINLESS STEEL ENCLOSURES EJB... series enclosures offer Ex d IIB +H 2 mode of protection. These enclosures are

More information

VALIADIS S.A. HELLENIC MOTORS

VALIADIS S.A. HELLENIC MOTORS Explosion proof motors MAK 56-250 (MAKe 63-250) series Groups IIB and IIC Ex db / Ex db e (EPL) executions Gb or Ex tb IIIC (EPL) Db II 2 G, II 2D, 2GD SAFETY INSTRUCTIONS Safety Instructions MAK and MAKe

More information

Model 4418F. Overview. Typical applications. Key features and benefits. Accreditations. Starting air/gas valve Vented fuel gas valve

Model 4418F.  Overview. Typical applications. Key features and benefits. Accreditations. Starting air/gas valve Vented fuel gas valve High Pressure Control Valve Model 4418F Overview The 4418F has been designed specifically for use as an air start valve for diesel engines or as a fuel shut-off valve for gas turbine applications. Its

More information

Terminal Boxes Series 8125

Terminal Boxes Series 8125 Series > Wide product range > Enclosure of electropolished stainless steel.0 (AISI L) or galvanised steel sheet painted > basic enclosure sizes various heights > Fitted according to the customer's requirements

More information

Thermostatic Valve. Filterstat - Model FJA. Typical applications. Key features and benefits. Mixing Diverting

Thermostatic Valve. Filterstat - Model FJA.   Typical applications. Key features and benefits. Mixing Diverting Thermostatic Valve Filterstat - Model FJA Typical applications Mixing Diverting Key features and benefits Direct filter connection Integral differential pressure switch Integral oil filter manifold Mount

More information

Flameproof Enclosures

Flameproof Enclosures Flameproof Enclosures The range comprises many standard sizes of enclosures manufactured in stainless steel 316L and/or in painted carbon steel. The enclosures allow for utilization of standard electrical

More information

by AMOT World class diesel engine safety solutions Automatic Engine Overspeed Shut Down Valves - D Series

by AMOT World class diesel engine safety solutions Automatic Engine Overspeed Shut Down Valves - D Series by AMOT World class diesel engine safety solutions Automatic Engine Overspeed Shut Down Valves - D Series Automatic Engine Overspeed Shut Down Valves Applications Cranes Fork Lift Trucks Aerial Platforms

More information

MPX-Series Diesel Engine Shut Down Valves (Manual Reset / Air Pressure and Manual Closure Options)

MPX-Series Diesel Engine Shut Down Valves (Manual Reset / Air Pressure and Manual Closure Options) MPX-Series Diesel Engine Shut Down Valves (Manual Reset / ir Pressure and Manual Closure Options) Selection, pplication and Maintenance Valve Numbers MPX-300 MPX-301 MPX-302 MPX-303 MPX-500 MPX-501 MPX-502

More information

Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L

Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L Temperature Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L WIKA data sheet TE 65.12 for further approvals see page 2 Applications Chemical industry Petrochemical industry

More information

The Earth-Rite MGV is designed to enable operators establish safe grounding of their vehicle in accordance with these recommended practices.

The Earth-Rite MGV is designed to enable operators establish safe grounding of their vehicle in accordance with these recommended practices. Earth-Rite MGV Mobile Ground Verification System ATEX IECEx SIL 2 The Earth-Rite Mobile Ground Verification system (MGV) is a unique, patented technology designed to provide automatic confirmation of a

More information

Flameproof Level Sensor (Flameproof F/S FP)

Flameproof Level Sensor (Flameproof F/S FP) The Deeter F/S FP is magnetic float on a reed switch or Hall Effect sensor stem for control and indication of a liquid level while in a potentially explosive atmosphere. II 1/2G 2D Ex d IIC (*) Ga/Gb Ex

More information

Model 4418F. Overview. Typical applications. Key features and benefits. Accreditations. Starting air/gas valve Vented fuel gas valve

Model 4418F.  Overview. Typical applications. Key features and benefits. Accreditations. Starting air/gas valve Vented fuel gas valve High Pressure Control Valve Model 4418F Overview The 4418F has been designed specifically for use as an air start valve for diesel engines or as a fuel shut-off valve for gas turbine applications. Its

More information

Metal Particle Detector

Metal Particle Detector Metal Particle Detector Model MPD Stainless steel Overview The Metal Particle Detector switch from AMOT can detect and alert equipment operations of the presence of metal particles in non-conductive fluid

More information

Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L

Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L Temperature Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L WIKA data sheet TE 60.12 for further approvals see page 2 Applications Chemical industry Petrochemical

More information

INSTALLATION AND SERVICE INSTRUCTIONS FOR 2000 SERIES FLAMEPROOF XENON AND FLUORESCENT BEACONS

INSTALLATION AND SERVICE INSTRUCTIONS FOR 2000 SERIES FLAMEPROOF XENON AND FLUORESCENT BEACONS INSTALLATION AND SERVICE INSTRUCTIONS FOR 2000 SERIES FLAMEPROOF XENON AND FLUORESCENT BEACONS Address all communications and shipments to: FEDERAL SIGNAL CORPORATION Industrial Systems Group 2645 Federal

More information

Terminal Boxes in Stainless Steel SLS**.T

Terminal Boxes in Stainless Steel SLS**.T Features Variant options Stainless steel enclosures Suitable for installation in Zones 0, 1, 2, 21 and 22 Certified Ex e, Ex ia and Ex tb 6 enclosure size options Various terminal and cable gland configurations

More information

Cable Glands - American Series - NEC/IEC

Cable Glands - American Series - NEC/IEC Cable Glands - 103 American Series - NEC/IEC 104 Cable Glands Explosion Proof & General Purpose Cable Gland/Connector Type 711 1 2 3 1 Unique Rear Sealing System This arrangement offers IP66, IP67, IP68

More information

EXPLOSION PROOF. Diesel Engines For Hazardous Areas

EXPLOSION PROOF. Diesel Engines For Hazardous Areas EXPLOSION PROOF Diesel Engines For Hazardous Areas HAZARDOUS AREAS Managing the Risk There is always a risk of a flammable hydrocarbon release in the oil and gas industry. When the release comes into contact

More information

ATX DPD Series Distribution Panelboards Flameproof

ATX DPD Series Distribution Panelboards Flameproof ATX DPD Series Distribution Panelboards Applications Protection and control of electrical equipment in hazardous areas where ignitable vapors, gases or highly combustible dusts are present. For installation

More information

11mm Slot Label S1 = 162, S2 = 170, S3 = 250, S4 = 305, S5 = 330, S6 = 410, S7 = 490, S8 = 570, S9 = 650. Maximum Power Dissipation (Watts) T** T**

11mm Slot Label S1 = 162, S2 = 170, S3 = 250, S4 = 305, S5 = 330, S6 = 410, S7 = 490, S8 = 570, S9 = 650. Maximum Power Dissipation (Watts) T** T** Assembly Instructions for: S1 Assembly to S Junction Instructions Boxes for: MS1 to MS Junction Boxes Boxes MS1 to MS Junction Boxes IMPORTANT: This document should be read carefully before commencing

More information

Floodlight LED Series 6125

Floodlight LED Series 6125 www.stahl.de > Floodlight Zones 1, 2 and 21, 22 with highly efficient LEDs > 3 different light distribution types for adjusting to the illumination task > Enclosure made of sheet steel single powder coated

More information

Linear luminaire with LED Series EXLUX 6002

Linear luminaire with LED Series EXLUX 6002 > latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking > All-pole disconnection by means of an N/C switch

More information

by AMOT World class diesel engine safety solutions Product Selection Guide

by AMOT World class diesel engine safety solutions Product Selection Guide by AMOT World class diesel engine safety solutions Product Selection Guide World class diesel engine safety solutions Diesel engines are a potential source of ignition when used in areas where combustible

More information

HTSB system System overview

HTSB system System overview HTSB system System overview Easy planning of heating circuits Simple installation on site Wide operating temperature range The BARTEC HTSB heating system covers a wide range of applications in trace heating.

More information

2000 Series Flameproof Xenon and Fluorescent Beacons Installation and Service Instructions

2000 Series Flameproof Xenon and Fluorescent Beacons Installation and Service Instructions 2000 Series Flameproof Xenon and Fluorescent Beacons Installation and Service Instructions 2562179B REV. B 818 Printed in USA 2013-2018 Federal Signal Corporation. All rights reserved. Limited Warranty

More information

ABG Cable Glands Installation Procedure

ABG Cable Glands Installation Procedure ABG Cable Glands Installation Procedure ABG Cable Gland Range Baseefa 16ATEX0004X IECEx BAS 16.0011X Installation, Operation and Maintenance Instructions Material: Brass/ Brass with Nickel plated and Stainless

More information

Pneumatic Indicating Relay

Pneumatic Indicating Relay Pneumatic Indicating Relay Model 2400D Overview The AMOT Model 2400D Pneumatic Indicating Relay pinpoints trouble and instantly provides easily visible trip indication. The first-out indication is held

More information

Solutions Ex d IIB+H2, Stainless Steel EJBX*

Solutions Ex d IIB+H2, Stainless Steel EJBX* Features Assembly Examples Enclosures manufactured from AISI 316L stainless steel Suitable for operation in Zones 1, 2, 21 and 22 Certified Ex d IIB+H2 and Ex tb More than 20 enclosure size options Free

More information

Is the heart of your engine protected?

Is the heart of your engine protected? Is the heart of your engine protected? Avoid open-up inspections and protect the heart of your engine with the AMOT Bearing Condition Monitor - XTS-W Bearing Condition Monitor Overview An essential tool

More information

Linear Luminaire with LED Series EXLUX 6002

Linear Luminaire with LED Series EXLUX 6002 > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking > All-pole disconnection by means of an N/C switch

More information

Control Buttons / Switches for Panel Mounting Series 8003

Control Buttons / Switches for Panel Mounting Series 8003 www.stahl.de > Different actuators pushbutton mushroom pushbutton mushroom stay-put button mushroom stay-put button with key lock key-operated button key-operated switch > 2 contact elements > Spring clamp

More information

Zone 1 Linear Range - Installation Guide

Zone 1 Linear Range - Installation Guide Zone 1 Linear Range - Installation Guide CML14ATEX3119 & IEC Ex CML15.0001 This installation guide provides instructions for installing SPARTAN series of explosion protected Zone 1 Linear luminaires. Text

More information

Load disconnect switch Series 8146/5-V11

Load disconnect switch Series 8146/5-V11 www.stahl.de Load disconnect switch > Motor switching capacity AC-3 and AC-23 acc. to DIN VDE 0660 part 107 IEC/EN 60947-3 > Isolating characteristics acc. to IEC/EN 60947-3 > Positive opening operation

More information

Position Switches Series 8060/2

Position Switches Series 8060/2 www.stahl.de > Ex e plastic enclosure > Operating temperature range -60 to +60 C > Dimensions and characteristic values according to EN 50047 > Degree of protection IP66 / IP67 > Extensive assortment of

More information

Terminal Boxes TNCN. Explosion protection Marking

Terminal Boxes TNCN. Explosion protection Marking Terminal boxes TNCN Terminal Boxes TNCN The TNCN range comprises many standard sizes of enclosures manufactured in stainless steel 316L for maximum environmental protection. The main box is manufactured

More information

USER MANUAL FOR THE BULKHEAD LIGHT FITTING, TYPE /..

USER MANUAL FOR THE BULKHEAD LIGHT FITTING, TYPE /.. d.o.o. tel. 049 222 900, fax 049 426 450 e-mail: tepex@tepex.hr www.tepex.hr USER MANUAL FOR THE BULKHEAD LIGHT FITTING, TYPE 0403.24/.. No: TEPEx.RS.077 Rev : 0 Date: 02.2016. CONTENT 1. Manufacturer

More information

Power (W) Tamb 40 o C LX1GAM4LB57 5,700 10, T3 T100 o C T4 T85 o C 13

Power (W) Tamb 40 o C LX1GAM4LB57 5,700 10, T3 T100 o C T4 T85 o C 13 Gamma Floodlight IP66/67 The Gamma is a high output LED floodlight is designed for use in Zone 1 & 21 hazardous areas. The compact design and flexible mounting allows the Gamma to also be used as a lowbay.

More information

Operating Instructions

Operating Instructions Operating Instructions Terminal Box > 8150/1 > 8150/2 Contents 1 Contents 1 Contents...2 2 General Information...2 2.1 Manufacturer...2 2.2 Operating Instructions Information...2 3 Intended Use...2 4 Safety

More information

Position Switches Series 8074/2

Position Switches Series 8074/2 www.stahl.de > Ex e metal enclosure > Operating temperature range -40 C... +70 C > Dimensions and characteristic values according to EN 50041 > Degree of protection IP66 > Extensive assortment of actuators,

More information

Operating Instructions

Operating Instructions Operating Instructions Pendant Light Fitting > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Instructions...3 4 Conformity to Standards...3 5 Intended Field of Application...3

More information

Resistance thermometer Model TR10-L, Ex d, for additional thermowell

Resistance thermometer Model TR10-L, Ex d, for additional thermowell Electrical temperature measurement Resistance thermometer Model TR10-L, Ex d, for additional thermowell WIKA data sheet TE 60.12 for further approvals see page 6 Applications Chemical industry Petrochemical

More information

Earth-Rite MGV. IECEx SIL 2. Leading the way in hazardous area static control. Mobile Ground Verification System

Earth-Rite MGV. IECEx SIL 2. Leading the way in hazardous area static control. Mobile Ground Verification System Earth-Rite MGV Mobile Ground Verification System ATEX IECEx SIL 2 The Earth-Rite Mobile Ground Verification system (MGV) is a unique, patented technology designed to provide automatic confirmation of a

More information

Automatic Fuel Shut Down Valves

Automatic Fuel Shut Down Valves Automatic Fuel Shut Down Valves Selection, Application and Maintenance Valve Numbers FSX-200 LST -200 DESCRIPTION FSX-200 Designed to automatically close on engine overspeed when used in conjunction with

More information

Oil Mist Detection multi-sensor-system for 2-stroke engines

Oil Mist Detection multi-sensor-system for 2-stroke engines VISATRON VN301 plus VN301 plus EX Oil Mist Detection multi-sensor-system for 2-stroke engines Technical Information System Features: Based on experience of 53000 + Schaller OMD systems in the field Tubeless

More information

Position Switches Series 8070/2

Position Switches Series 8070/2 www.stahl.de > Ex e plastic enclosure > Operating temperature range -60 to +60 C > Dimensions and characteristic values according to EN 50041 > Degree of protection IP66 / IP67 > Extensive assortment of

More information

Wellglass fittings EVH, EVX Wellglass fitting all zones - zones 1, 2, 21 & 22

Wellglass fittings EVH, EVX Wellglass fitting all zones - zones 1, 2, 21 & 22 WELLGLASS - EVH, EVX WELLGLASS FITTING - S 1, 2, 21 & 22 127 Wellglass fittings Features Compact design for easy installation For diffuse or ambient light Compatible with energy saving lamps or discharge

More information

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1 > For use in Zones 1, 2, 21, 22 and safe area > 2-lamp version: 18 W 36 W > Housing made of sheet steel or stainless steel SS304 / > Quick fasteners www.stahl.de 15709E00 The light fittings of Series ECOLUX

More information

Ex m Solenoid Operator Type 0519

Ex m Solenoid Operator Type 0519 nass magnet GmbH Eckenerstrasse 4-6 D-30179 Hannover Doc. No. 113-720-0002 Revision No. 2 01.06.2015 Ex m Solenoid Operator Type 0519 Operating Instructions Dear Customer! To ensure the function and for

More information

EXPLOSION PROOF. Diesel Engines For Hazardous Areas

EXPLOSION PROOF. Diesel Engines For Hazardous Areas EXPLOSION PROOF Diesel Engines For Hazardous Areas HAZARDOUS AREAS Managing the Risk There is always a risk of a flammable hydrocarbon release in the oil and gas industry. When the release comes into contact

More information

Diesel Engine Shutdown System

Diesel Engine Shutdown System Diesel Engine Shutdown System Models CSX-300, 310 CSX-301, 311 Typical applications Marine engine safety Petrochemical industry safety Vacuum trucks Cranes - both engines Land drilling rigs Offshore equipment

More information

Emergency Luminaire with LED Series EXLUX 6009/1 Version IIC

Emergency Luminaire with LED Series EXLUX 6009/1 Version IIC > For use in hazardous areas with gas group IIC > Emergency luminaire for wall, ceiling, pendant or pole installation > Latest LED technology with a high luminous efficacy and a long service life > Central

More information

Explosion proof electric motor For Fuel dispensing application. Main characteristic

Explosion proof electric motor For Fuel dispensing application. Main characteristic Ad-pe ed.2018/0 1 Explosion proof electric motor For Fuel dispensing application RAEL motori elettrici, since its inception in the late 60s, has assembled more than a million of explosion proof electric

More information

COMBUSTION AND ENERGY

COMBUSTION AND ENERGY CATALOGUE 2015 COMBUSTION AND ENERGY COMBUSTION AND ENERGY SRL VIA PER DOLZAGO, 21-23848 OGGIONO (LC) - ITALY - PH. +39 0 341.260926 - FAX +39 0 341.577747 INTERNATIONAL STANDARDS The ATEX directive consists

More information

ANKERSMID Temperature controller ATC 510/520/525 for wall-mounting. Application

ANKERSMID Temperature controller ATC 510/520/525 for wall-mounting. Application 2-3.1 ATC 510/520/525 for wall-mounting Application The ATC 510/5205/525 is a modern microprocessor-based (PID) control device featuring easy handling and a digital display. The clear design of the operator

More information

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401 > As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp

More information

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve Ex d Ex m IP5 Series 3 Way Direct Acting Balanced Poppet Solenoid Valve DB2S-M2C \ Ex d IIC with Integral Stainless \ Steel Junction Box. \ Valve. \ Manual Override, Option M2. J77072S-M2 \ Ex m II NASS

More information

Model J. Thermostatic Control Valves. Typical applications. Key benefits. Key features. Accreditations available

Model J. Thermostatic Control Valves.  Typical applications. Key benefits. Key features. Accreditations available Thermostatic Control Valves Model J Typical applications Lubricating oil temperature control Jacket water high temperature (HT) Secondary water low temperature (LT) Heat recovery Water saving applications

More information

Explosion Protected Group IIB Zone 1 Ex d Ring Enclosure Ex e Terminal Boxes Hollow Shaft Option OPERATING SPECIFICATION TECHNICAL DETAILS

Explosion Protected Group IIB Zone 1 Ex d Ring Enclosure Ex e Terminal Boxes Hollow Shaft Option OPERATING SPECIFICATION TECHNICAL DETAILS Ex d Ring Enclosure Ex e Terminal Boxes Hollow Option Ambient Temperature Maximum Throughput Current Protection Mounting (increased range available) 20 rpm (higher on request) 770V ac 1166 Amps In any

More information

JBEP Series Fiberglass Reinforced Polyester Terminal Junction Boxes for Instrumentation Applications Increased Safety. Factory Drilled and Equipped

JBEP Series Fiberglass Reinforced Polyester Terminal Junction Boxes for Instrumentation Applications Increased Safety. Factory Drilled and Equipped Enclosures and Junction Boxes Enclosures and Junction Boxes: Hazardous Location Outlet Boxes Applications Instrumentation junction boxes are used to run process or remote information to control room. For

More information

3-Way Temperature Control Valve

3-Way Temperature Control Valve 12/06 3-Way Temperature Control Valve G Valve Typical applications Lubricating oil temperature control Jacket water cooling Charge air temperature control Central cooling Sea water cooling Key benefits

More information

Brushless Servo Motors

Brushless Servo Motors Brushless Servo Motors For Highly Dynamic Applications flexible design to support high MACHINE productivity WHAT MOVES YOUR WORLD DYNAMIC APPLICATIONS SUPERIOR PERFORMANCE For over two decades, Moog has

More information

Solenoid coils VACF Type codes

Solenoid coils VACF Type codes Solenoid coils VACF Type codes VACF B B2 1A Type VACF Solenoid coil, F series Solenoid coil type A B Width 30 mm, for 8 mm armature tube Width 22 mm, for 8 mm armature tube A1 Connection pattern type A,

More information

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC > For use in hazardous areas with gas group IIC > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking

More information

EVZ Series (Small body) Explosion protected luminaire Operating Instructions

EVZ Series (Small body) Explosion protected luminaire Operating Instructions EVZ Series (Small body) Explosion protected luminaire Operating Instructions Cooper Crouse-H i n d s Cooper E l ec t ron i c T ec h n ol og i es ( S h a n g h a i ) Co., L t d. No. 955 Shengli Road, East

More information

Emergency Light Fitting for Fluorescent Lamps Series 6009

Emergency Light Fitting for Fluorescent Lamps Series 6009 > As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W and 36 W > Central locking > All-pole disconnection via N/C switch when opening light fitting or

More information

Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06

Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06 www.atos.com Table TF040-2/E Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06 A B DHRZO-A-012/25 A B DHRZA-A-010/25 DHRZ* are

More information

YFC. Limit switch. Ex d. 24 operating head types

YFC. Limit switch. Ex d. 24 operating head types Ex d YFC Limit switch 24 operating head types - Group IIC - Zone 1, 2, 21, 22 - Aluminium alloy - Easy installation, wiring and maintenance - Durable and safe over time Fastening system Earth screw RAL735

More information

EXEL-L. Detail of the internal side. Transparent polycarbonate

EXEL-L. Detail of the internal side. Transparent polycarbonate EXEL-L - Complete with high efficiency LED tubes - Quick access to the internal electrical equipment - Double locking system operated by hexagonal-head tool - Zone 1, 2, 21, 22 Reinforced polyester resin

More information

ILED Aquarius Illuminated Windsock. User Manual

ILED Aquarius Illuminated Windsock. User Manual Contents 1. Safety... 3 2. Warranty... 3 2.1 General... 3 2.2 Life span... 3 3. Type plate... 4 3.1 The light fitting has a type plate:... 4 3.2 The junction box has a type plate:... 5 4. Product Description...

More information

GRD Electronic earthing system. Ex d. Polyester coating RAL7035. LED indicators

GRD Electronic earthing system. Ex d. Polyester coating RAL7035. LED indicators Ex d GRD-4200 Electronic earthing system - Zone 1, 2, 21, 22 - High quality electronic components - High resistance to corrosion and extreme weather - Safe and reliable over time SIL certified Level 2

More information

Ex d. S.1 series. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Wide selection of models - IP66 / 67. SSC series

Ex d. S.1 series. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Wide selection of models - IP66 / 67. SSC series Ex d S S.1 series - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Wide selection of models - IP66 / 67 SSC series Temperature sensor box SWS series SF series A.117 S... series Junction boxes

More information