SmartCom 3. Cabinet Heaters. Heat Exchanger models. Cabinet Heaters. VN/VD Vertical Heaters. HN/HD Horizontal Heaters. RN/RD Downflow Heaters

Size: px
Start display at page:

Download "SmartCom 3. Cabinet Heaters. Heat Exchanger models. Cabinet Heaters. VN/VD Vertical Heaters. HN/HD Horizontal Heaters. RN/RD Downflow Heaters"

Transcription

1 Smartom 3 abinet eaters eat Exchanger models VR as and xial Oil an ired abinet eaters VN/V Vertical eaters N/ orizontal eaters RN/R ownflow eaters

2 abinet eaters Introduction The enson range of cabinet heaters combines innovative design with a proven four pass heat exchanger technology to provide a high effi ciency cost effective and durable range. The units may be specifi ed for either free blowing applications or for use with ductwork. Units are manufactured in accordance with ISO 1 accreditation, all heater effi ciencies are compliant with Part L2 of the 2010 uilding Regulations with the majority of models also meeting the higher effi ciency requirements for Enhanced apital llowances. Options igh low or fully modulating burners ombustion air adaptors Stainless steel tubular heat exchanger ir inlet spigots ir inlet fi lters Manual or motorised inlet dampers Up rated fan motor for increased static pressure pplications actories Warehouses Workshops Showrooms reenhouses Model Range abinet heaters are available as either gas or oil fi red models. as fi red cabinet heaters are suitable for use with Natural as (20), most units can also be specifi ed for Propane (31) Oil fi red cabinet heaters are suitable for use with lass gas oil (35 sec), most units can also be specifi ed for erosene (28 sec oil) Vertical freestanding models are available from 32kW to 380kW orizontal and own fl ow models from 58kW to 380kW E This symbol verifi es that the product has been independently assessed and currently qualifi es for the E scheme, an upfront tax relief enabling businesses that invest in energy-saving equipment to claim 100% fi rst-year capital allowances against their taxable profi ts.

3 Specification abinets abinets are constructed from electro-zinc coated steel with an inner heat shield skin and an epoxy powder coat fi nish outer skin to form a rigid and durable casework. ir istribution entrifugal fan(s) circulate large air volumes evenly across the full heat exchanger surface for enhanced life expectancy. ans on models 30 to 85 are direct drive with a single phase motor. Larger models have belt drive fans and three phase motors compliant with directive 2005/32/E. ree blowing heaters are fi tted with long throw discharge nozzles complete with horizontal louvres. Nozzles can be rotated through 360 o. Models are supplied with a raised rear nozzle (one per three nozzle heater and two per four nozzle heater). eaters for use with ductwork are supplied with a duct outlet spigot. eat Exchanger and urner our pass combustion chamber/heat exchanger assembly provides improved thermal effi ciency with extended life expectancy. stainless steel chamber is combined with a high effi ciency tubular heat exchanger to achieve thermal effi ciency in excess of 91% The complete assembly is mounted to allow for thermal expansion thereby avoiding undue thermal stress and premature heat exchanger failure. as fi red units are fi tted with a fully automatic forced draught burner complete with full safety controls to EN676 and the heaters are E certifi ed. Oil fi red units are supplied complete with a fully automatic burner complete with safety controls and factory fi tted fi re valve and oil fi lter. n additional external fi re valve may be required in accordance with S 510:Part2:1978. ontrols combined fan and limit switch is fi tted on all heaters. In the event of overheating the unit would automatically be shut down by the limit thermostat. ll heaters are supplied with an electronic programmer complete with optimised control, this is factory fi tted and wired on free-blowing vertical models. or horizontal, and all duct outlet models down fl ow heaters the controller is supplied loose for on site wiring by the installer. TENIL T New Model Ref Old Model Ref as ired E pproved* Nominal heat output Temperature rise as onsumption Nat gas 20 as onsumption propane 31 Minimum inlet pressure Nat gas 20 Minimum inlet pressure propane 31 as onnection kw m 3 /h m 3 /h mbar mbar Rc ¾ ¾ ¼ ¼ ¼ Oil ired E pproved* Nominal heat output Temperature rise Oil onsumption Oil onnection ir andling ata irflow Throw 1 (N Type) Static pressure ( Type) Std motor Increased motor Main fan motor L 230/1/50 L 15/3/50 Up-rated fan motor L 13/3/50 eneral ata lue diameter Nominal ombustion air diameter Nominal Noise level 3 Net weight kw l/h Rc m 3 /s m Pa Pa kw amp amp kw amp mmø mmø d() kg Throw is dependent on building height, room temperature and nozzle settings. 3 Noise levels measured at 5 metres from appliance. 2 as lines must be adequately sized and reduced at appliance as required. *Please check ETL at time of ordering for latest listings as criteria are subject to change

4 abinet eaters Vertical eaters VN/V Eø L ront View Side View IMENSIONS New Model Ref Old Model Ref E mmø Oil as Standard Extended L eaters with 3 or nozzles are supplied with extended head on the rear nozzle(s). or applications with restricted headroom, units may be specifi ed with all nozzles at standard height

5 ir ischarge and Inlet etails VN/V Nozzle outlet Nozzle outlet Nozzle outlet uct outlet spigot Return ir spigots and ilters VN/V Side inlet spigot left (as shown) or right - please specify at time of order Rear inlet spigot Side inlet fi lter Left (as shown) or right - please specify at time of order. dditional side inlet spigot is required to connect fi lter box to inlet ductwork IMENSIONS New Model Ref Old Model Ref ead plan (VN) Nozzle detail (VN) Outlet Spigot (V) Side Inlet Spigot (VN/V) Rear Inlet Spigot (VN/V) Inlet ilter ssembly (VN/V) Installation learances ront Side Rear no. Spigot ø E ilter cassettes can be withdrawn from either side, ensure adequate clearance for withdrawal i.e. full width of fi lter box

6 abinet eaters orizontal eaters N/ L Eø M N 5 5 P 92 R S Q Side View End View Note: Units may be specifi ed for airfl ow right to left which is the standard confi guration as shown. lternatively units can be specifi ed for airfl ow left to right. Plan View IMENSIONS New Model Ref Old Model Ref E mmø Oil as L mmø M N P Q R S

7 ownflow eaters RN/R 5 N M 5 P Eø L ront View Side View IMENSIONS New Model Ref Old Model Ref E mmø Oil as L M N P

8 ir ischarge and Inlet etails ischarge outlets (N/RN) (ll N/RN models are supplied with louvred outlets) Outlet spigot (/R) (lue location shown for standard R-L horizontal airfl ow) End inlet spigot (N/RN /R) (urner location shown for standard R-L horizontal airfl ow) lternative Return ir Spigots E E Top or bottom inlet spigot N/ Rear inlet spigot N/ Side inlet spigot RN/R Rear inlet spigot RN/R ir ilters Top or bottom inlet fi lter N/ Side inlet fi lter RN/R IMENSIONS New Model Ref Old Model Ref Nozzle ø (N/RN) uct Spigot (ll) Top & Side Inlet (N/ & RN/R) Rear Inlet (N/) Installation learances ront Top (RN/R) Top 1 (N/) Rear E Top clearance applies to units with side air inlet. or units with top air inlet allow mm /EN/009/0111 enson eating, Ludlow Road nighton, Powys, L7 1LP United ingdom Telephone acsimile sales@bensonheating.co.uk Website enson eating Ltd is a registered trademark of mbirad Limited. ecause of continuous product innovation, enson eating reserves the right to change product specifi cation without due notice.

Specification abinets abinets are constructed from electro-zinc coated steel with an inner heat shield skin and an epoxy powder coat fi nish outer ski

Specification abinets abinets are constructed from electro-zinc coated steel with an inner heat shield skin and an epoxy powder coat fi nish outer ski abinet eaters Introduction The enson range of cabinet heaters combines innovative design with a proven four pass heat exchanger technology to provide a high effi ciency cost effective and durable range.

More information

C SmartCom3 Heat Exchanger models abinet Heaters

C SmartCom3 Heat Exchanger models abinet Heaters abinet eaters Smartom 3 eat xchanger models VR orced xial raught an as and Oil ired abinet eaters VN/V Vertical eaters N/ orizontal eaters RN/R ownflow eaters abinet eaters Introduction The enson range

More information

... Cabinet Heaters Gas & Oil Fired Heaters ...

... Cabinet Heaters Gas & Oil Fired Heaters ... abinet eaters as & Oil ired eaters abinet heaters Introduction The Reznor range of cabinet heaters combines innovative design with a proven four pass heat exchanger technology to provide a high efficiency

More information

BENSON AMBIRAD. ... Cabinet Heaters Gas & Oil Fired Heaters ... HEATI NG AND VENTILATION S OLUTIONS

BENSON AMBIRAD. ... Cabinet Heaters Gas & Oil Fired Heaters ... HEATI NG AND VENTILATION S OLUTIONS NSON abinet eaters as & Oil ired eaters MIR TI N N VNTILTION S OLUTIONS abinet eaters... abinet heaters combine innovative design with a proven four pass heat exchanger technology to provide a high efficiency

More information

... Cabinet Heaters Gas & Oil Fired Heaters ... ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

... Cabinet Heaters Gas & Oil Fired Heaters ... ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant abinet eaters as & Oil ired eaters rp 2018 rp Lot 21 Seasonal fficiency and NOx compliant abinet eaters... abinet heaters combine innovative design with a proven four pass heat exchanger technology to

More information

NVx Gas Unit Heater Range Controlling your working environment. heating ventilation integrity

NVx Gas Unit Heater Range Controlling your working environment. heating ventilation integrity NVx as Unit Heater Range Controlling your working environment heating ventilation integrity enefits Installer Friendly New compact model Horizontal wall exit flue discharge option (no roof work) Room sealed

More information

Air Handlers Series. Direct-Fired Heating Pressurization. Dimension and Selection Guide

Air Handlers Series. Direct-Fired Heating Pressurization. Dimension and Selection Guide 2000-Series ir andlers irect-ired eating Pressurization imension and Selection uide 1.800.536.3461 www.rapidengineering.com N: 100% OUTSI IR ONLY 2000-Series Selection uide IMPORTNT NOTS: ll information

More information

VITALITY Centrifugal Large Split

VITALITY Centrifugal Large Split VITITY entrifugal arge Split V-VIR 20 to 90 complete range from 16.8 kw up to 87.3 kw Y2open eatures ew Y2open board igh efficiency R and P conomizer or motorized damper Indoor air quality ot water coil

More information

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE. TECHNICAL SELECTION DATA PACKAGE UNIT + o C -10 o C 3 THREE PHASE SCROLL TWO STAGE CENTRIFUGAL LOUVRE LIANT SCROLL RESSOR AXIAL UNIT FEATURES SPECIFICATION SUMMARY Scroll Compressor Multiple Speed Outdoor

More information

Axial-flow Fan AFC. Model numbering system AF C / T. Accessories Three phase. Power rate 1.

Axial-flow Fan AFC. Model numbering system AF C / T. Accessories Three phase. Power rate 1. xial-flow Fan FC Construction xial fan designed for installation in a ducted system. Casing of rolled and electro-welded steel sheet, powder coated RL5. Impeller in polypropylene. Casing in acid-proof

More information

VIESMANN VITODENS 222-F

VIESMANN VITODENS 222-F VISMNN VITONS 222- atasheet or part no. and prices: see pricelist VITONS 222- Type 2T as condensing storage combi boiler, 3.2 to 35. kw for natural gas and LP VITONS 222- Type 2S as condensing storage

More information

HEATING HEATING EQUIPMENT FOR AGRICULTURAL AND INDUSTRIAL APPLICATIONS. since

HEATING HEATING EQUIPMENT FOR AGRICULTURAL AND INDUSTRIAL APPLICATIONS. since HTING HTING QUIPMNT FOR GRIULTURL N INUSTRIL PPLITIONS since 1967 IRT GS-FIR IR HTR The air heater agritrm was developed for livestock buildings. It is entirely made of stainless steel for the maximum

More information

D F B. DFBH Rooftop Unit DFBV

D F B. DFBH Rooftop Unit DFBV SYSTEM, UAL LOWER MOEL H Rooftop Unit V ive Sizes H - Horizontal Configuration with ull Curb Cap ase and either Horizontal or Vertical (down) ischarge V - Vertical Configuration with Horizontal ischarge,

More information

MAKING REFRIGERATION GREENER

MAKING REFRIGERATION GREENER Searle KME air cooler MAKING RERIGERATION GREENER The Searle KME cooler range from Kelvion is ideally suited to large cold rooms and small warehouses where an efficient cooling solution is required. The

More information

GMH95/GCH9 PRODUCT SPECIFICATIONS 95%/93% AFUE HEAT REPLACEMENT MULTI-POSITION, TWO-STAGE (CONVERTIBLE), MULTI-SPEED GAS FURNACE

GMH95/GCH9 PRODUCT SPECIFICATIONS 95%/93% AFUE HEAT REPLACEMENT MULTI-POSITION, TWO-STAGE (CONVERTIBLE), MULTI-SPEED GAS FURNACE / 95%/93% AFUE MULTI-POSITION, TWO-STAGE (CONVERTIBLE), MULTI-SPEED GAS FURNACE HEATING INPUT: 46,000 115,000 BTU/H LIFETIME HEAT EXCHANGER LIMITED WARRANTY 10 YEAR HEAT REPLACEMENT CXCHANGER WARRANTY

More information

Tranquility (TBW) Water-To-Water Series. WATER-TO-WATER SYSTEMS SIZES 036, 060, AND 120 [8.7, 13.5 and 26.9 kw]

Tranquility (TBW) Water-To-Water Series. WATER-TO-WATER SYSTEMS SIZES 036, 060, AND 120 [8.7, 13.5 and 26.9 kw] Tranquility () Water-To-Water Series WATER-TO-WATER SYSTEMS SIZES 036, 060, AND 120 [8.7, 13.5 and 26.9 kw] Tranquility Water-To-Water () Series Table of Contents Design Features...4 Unit Model Key...5

More information

FH Fan-Coil Units Low-Profile, Horizontal

FH Fan-Coil Units Low-Profile, Horizontal FH Fan-oil Units Low-Profile, Horizontal FH Fan-oil Units: Innovative design simplifies installation and service Owners HRI Standard 440-certifi cation ensures exacting performance. The FH fan-coil unit

More information

BFC Cyclone Condensing Glass-Lined Water Heater

BFC Cyclone Condensing Glass-Lined Water Heater ondensing Glass-Lined ater eater BF - 28/0/0/0/80/100/120 Fully room-sealed condensing high-efficiency water heater 97% (gross) utomatic gas/air premix burning system including burner modulation elivered

More information

MTD Silent Series MIXED FLOW IN-LINE DUCT FAN

MTD Silent Series MIXED FLOW IN-LINE DUCT FAN MT Silent Series MIX LOW IN-LIN UT N Mixed low In-Line uct an MT Silent Series MT Silent 100/2~200/2 MT Silent 250~315 Low profile Mixed-flow fans with sound- absorbent insulation. xtreme ly quiet. General

More information

Product Catalogue ARMONIA Providing indoor climate comfort

Product Catalogue ARMONIA Providing indoor climate comfort Product Catalogue ARMONIA Providing indoor climate comfort ARMONIA 1,3-11 kw Water cassette Main applications Light commercial buildings Offi ces Shops General description Why this choice? Silent operation

More information

ELD Series - DC Motor Drive

ELD Series - DC Motor Drive ELD Series - D Motor Drive ir ooled Oil oolers for Mobile pplications Description These coolers use a combination of high performance cooling elements and long life D electrical powered fans to give extended

More information

Boosters N Series Initial pressure up to 13 bar Final pressure up to 45 bar Flow rate m³/min

Boosters N Series Initial pressure up to 13 bar Final pressure up to 45 bar Flow rate m³/min www.kaeser.com Boosters N Series Initial up to 13 bar Final up to 45 bar Flow rate.27 2.51 m³/ hy boosters? The ability to offer compressed air at various s makes it one of the most versatile energy sources

More information

Economite RE Series. Power Gas Burners. MADE in the USA

Economite RE Series. Power Gas Burners. MADE in the USA Economite RE Series MADE in the USA Economite RE 4000 Series MADE in the USA Midco s Economite Family of Burners Backed by 60 Years of Experience 4.00" 6.00" 12.00" RE 4400DS 9.00" 15.75" 20.50" 8.44"

More information

RME 110 RME 110 IVR RMF RMF IVR. Robust, reliable, efficient. Maximum benefits in compressed air.

RME 110 RME 110 IVR RMF RMF IVR. Robust, reliable, efficient. Maximum benefits in compressed air. RME 110 RME 110 IVR RMF 110-160 RMF 132-180 IVR Gearbox driven Oil-injected screw compressors Fixed and variable speed Robust, reliable, efficient. Maximum benefits in compressed air. Time-proven reliability

More information

Direct-Fired Heating, Ventilation and Pressurization Systems

Direct-Fired Heating, Ventilation and Pressurization Systems 2000-Series irect-ired Heating, Ventilation and Pressurization Systems imension and Selection uide 1.800.536.3461 www.rapidengineering.com N: 100% OUTSI IR ONLY 2000-Series Selection uide NOT: ll information

More information

Landmark Rooftop Packaged Units

Landmark Rooftop Packaged Units Landmark Rooftop Packaged Units Engineered for superior performance and reliability Exclusively distributed by AUS - 13 23 50 www.lennoxaus.com.au NZ - 0800 653 330 www.lennoxnz.co.nz 1 Landmark Rooftop

More information

Q4SD Series TECHNICAL SPECIFICATIONS. Single Packaged Heat Pump, Single Phase FEATURES AND BENEFITS

Q4SD Series TECHNICAL SPECIFICATIONS. Single Packaged Heat Pump, Single Phase FEATURES AND BENEFITS TM TECHNICAL SPECIFICATIONS Q4SD Series Single Packaged Heat Pump, Single Phase Q4SD-13 SEER 3-5 Ton Units Cooling: 30,000 to 58,000 Btuh Heating: 29,000 to 59,000 Btuh The Q4 Series single packaged heat

More information

ISDL SERIES DUCTED SPLIT SYSTEM AIR CONDITIONERS

ISDL SERIES DUCTED SPLIT SYSTEM AIR CONDITIONERS Ducted Split System Air Conditioners Technical Data ISDL Series Optional HAN-L6 Controller Extra Long Life Epoxy Coated Outdoor Coil Nominal Cooling Capacity 2.9 kw 1. kw JANUARY 5 ISDL SERIES DUCTED SPLIT

More information

Making refrigeration greener KELVION KME COMMERCIAL AIR COOLER

Making refrigeration greener KELVION KME COMMERCIAL AIR COOLER Making refrigeration greener KELVION KME COMMERCIAL COOLER Kelvion a tribute to Lord Kelvin Lord Kelvin (1824 1907) formulated the laws of thermodynamics 70 branches and sales partners worldwide More

More information

BFC Cyclone Condensing Glass-Lined Water Heater

BFC Cyclone Condensing Glass-Lined Water Heater ondensing Glass-Lined ater eater BF - 28/0/0/0/80/100/120 Fully room-sealed condensing high-efficiency water heater 97% (gross) utomatic gas/air premix burning system including burner modulation elivered

More information

GQ3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS

GQ3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS GQ3RD Series Single Packaged Heat Pump, Single Phase GQ3RD-13 SEER 2 thru 4 Ton Units Cooling: 24,000 to 48,000 Btuh Heating: 23,200 to 48,000 Btuh The GQ3 Series single packaged

More information

PARTS LIST FOR SH-100LP, SH-155LP AND SH-375LP

PARTS LIST FOR SH-100LP, SH-155LP AND SH-375LP PARTS LIST FOR SH-100LP, SH-155LP AND SH-375LP Space Heaters This Parts Listing has been compiled for your benefit. You can be assured your space heater was constructed and designed with quality and performance

More information

1 AIR HANDLING UNIT TYPE AIR ACCESS 75

1 AIR HANDLING UNIT TYPE AIR ACCESS 75 SUPPLY 1 AIR HANDLING UNIT TYPE AIR ACCESS 75 Location : EXTERNAL Position : SIDE BY SIDE SLIDING PANELS for COMPLETE ACCESSIBILITY MULTI SERVICE BULKHEAD for HYDRAULIC AND ELECTRICAL CONNECTIONS Self-supporting

More information

TECHNICAL GUIDE 80 AFUE MULTI-POSITION GAS FURNACES MODELS: G8C SERIES 4-POSITION MBH INPUT 3-POSITION 150 MBH INPUT DESCRIPTION WARRANTY

TECHNICAL GUIDE 80 AFUE MULTI-POSITION GAS FURNACES MODELS: G8C SERIES 4-POSITION MBH INPUT 3-POSITION 150 MBH INPUT DESCRIPTION WARRANTY TEHNIAL GUIE 80 AFUE MULTI-POSITION GAS FURNAES MOELS: G8 SERIES 4-POSITION 50-125 MH INPUT 3-POSITION 150 MH INPUT EFFIIENY RATING ERTIFIE ISO 9001 ertified Quality Management System ESRIPTION These compact

More information

SPLIT DUCTED UNIT SCA300C / SCA300E TECHNICAL SELECTION DATA SPECIFICATION SUMMARY UNIT FEATURES CONTROL OPTIONS UNIT COMPLIANCE

SPLIT DUCTED UNIT SCA300C / SCA300E TECHNICAL SELECTION DATA SPECIFICATION SUMMARY UNIT FEATURES CONTROL OPTIONS UNIT COMPLIANCE TECHNICAL SELECTION DATA SPLIT DUCTED UNIT 3 THREE PHASE SCROLL TWO STAGE CENTRIFUGAL LOUVRE AXIAL UNIT FEATURES Scroll Compressor Multiple Speed Outdoor Fans Louvred Outdoor Coil Guard Pre-charged with

More information

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw Air-to-Water Reverse Cycle Heat Pumps VLH 504 to 1204 126 to 294 kw 133 to 307 kw Technical Brochure TM VLH-N.3GB Date : June 2005 Supersedes : TM VLH-N.2GB/07.04 Specifications Advantages Range extension

More information

LIST PRICES WAC AIR CURTAINS

LIST PRICES WAC AIR CURTAINS PRICE SHEET PSWAC-2 EFFECTIVE: March 1, 2011 SUPERSEDES: PSWAC-1 LIST PRICES WAC AIR CURTAINS 4830 TRANSPORT DRIVE, DALLAS, TX 75247 PHONE: 214-638-6010 FAX: 214-905-0806 WAC AIR CURTAINS Basic Unit ITEM

More information

AHTW Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology

AHTW Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology HANDLERS LTD AHTW Compact Heat Recovery Air Handling Unit 1262 Acoustic Testing Laboratory College of Science & Technology BIM & REVIT Engineering Solutions The Company Air Handlers has been trading since

More information

Model FDD Dynamic Curtain Fire Damper 1-½ or 3 Hour, UL555 Listed

Model FDD Dynamic Curtain Fire Damper 1-½ or 3 Hour, UL555 Listed Tag: Project: Engineer: Contractor: Location: ate: pplication: rchitect: Submitted by: The NC model F fire damper utilizes a curtain style blade to prevent the spread of fire through a penetration in a

More information

Technical Data. 400 Series 403D-11G. ElectropaK

Technical Data. 400 Series 403D-11G. ElectropaK Technical Data 400 Series 403D-11G ElectropaK Basic technical data Number of cylinders.................................................... 3 Cylinder arrangement.................................... Vertical

More information

Serenity GT Series. Two-Stage, R-410a Packaged Horizontal & Vertical Unit Specifi cations Catalog.

Serenity GT Series. Two-Stage, R-410a Packaged Horizontal & Vertical Unit Specifi cations Catalog. Serenity GT Series Two-Stage, R-410a Packaged Horizontal & Vertical Unit Specifi cations Catalog Table of Contents: Product Introduction & Unit Features...2 Performance Data: AHRI - Single Compressor...3

More information

RMB & RMB IVR kw

RMB & RMB IVR kw RMB & RMB IVR 26-37 kw Solid, simple, smart: Advanced reliability in compressed air RMB 26-37 Gear driven RMB 26-37 IVR Direct driven Compressed air drives your company. Consequently, choosing the right

More information

Compressed Air Filtration

Compressed Air Filtration DF Depth Filter / Coalescence Filter / Particle Filter MAIN FEATURES & BENEFITS: Coalescence / particle filter for the retention of oil and water aerosols as well as particles from compressed air or gases

More information

Compressed Air Filtration

Compressed Air Filtration DF Depth Filter / Coalescence Filter / Particle Filter MAIN FEATURES & BENEFITS: Coalescence / particle filter for the retention of oil and water aerosols as well as particles from compressed air or gases

More information

Air-Cooled Liquid Chiller with integrated hydraulic module

Air-Cooled Liquid Chiller with integrated hydraulic module Air-Cooled Liquid Chiller with integrated hydraulic module Cooling only: CGAN 200-250 - 300-400 - 450-490 - 500-600 - 700-800 - 900-925 Reversible: CXAN 200-250 - 300-400 - 450-490 - 500-600 - 700-800

More information

RANGE. STD Version (Standard): HEE Version (High Energy Efficiency): OPERATION LIMITS. Series LP 46ºC 12ºC 18ºC 5ºC

RANGE. STD Version (Standard): HEE Version (High Energy Efficiency): OPERATION LIMITS. Series LP 46ºC 12ºC 18ºC 5ºC Cooling capacity: Heating capacity: 17,7 to 74,3 kw 21,8 to 84,8 kw Scroll compressors R-410A refrigerant Compact and silent design Cooling solution where an outdoor installation is impossible DESCRIPTION

More information

TD-SILENT range, the quietest fans in the world in their class

TD-SILENT range, the quietest fans in the world in their class TD-SILNT IN-LIN MIXD LOW DUT NS ULTR-QUIT TD-SILNT Series NW Low profile Mixed-flow fans with sound-absorbent insulation. xtremely quiet. Manufactured in plastic material, with a specifically designed

More information

Spacemaster SX Electric Wire Rope Hoists

Spacemaster SX Electric Wire Rope Hoists www.rmhoist.com Spacemaster SX Electric Wire Rope Hoists Innovation... Performance... Reliability 1/2-80 Ton (500-80,000 kg) The Spacemaster SX represents a revolutionary new generation of exceptionally

More information

Model FD Static Curtain Fire Damper 1-½ or 3 Hour, UL555 Listed

Model FD Static Curtain Fire Damper 1-½ or 3 Hour, UL555 Listed Tag: Project: Engineer: Contractor: Location: ate: pplication: rchitect: Submitted by: The NC model F fire damper utilizes a curtain style blade to prevent the spread of fire through a penetration in a

More information

Technical Data. 400 Series 403D-15G. ElectropaK

Technical Data. 400 Series 403D-15G. ElectropaK Technical Data 400 Series 403D-15G ElectropaK Basic technical data Number of cylinders.................................................... 3 Cylinder arrangement.................................... Vertical

More information

GAS FURNACES CLASSIC SERIES SUPER QUIET % A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES

GAS FURNACES CLASSIC SERIES SUPER QUIET % A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES FORM NO. G11-485 REV. 5 Supersedes Form No. G11-485 Rev. 4 GAS FURNACES RGPN- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] (U.S. & Canadian Models) ISO 9001:2000 Annual Fuel

More information

BD Series. Backdraught Volume Regulating Damper M A N U F A C T U R E R S O F A I R, F I R E A N D S M O K E C O N T R O L P R O D U C T S

BD Series. Backdraught Volume Regulating Damper M A N U F A C T U R E R S O F A I R, F I R E A N D S M O K E C O N T R O L P R O D U C T S V11711 D Series ackdraught Volume Regulating Damper Extruded aluminium blades DW144 compliant Galvanised mild steel casing with stainless steel option Flange or spigot casing options Infinite sizing capability

More information

UTA STANDARD. Ductable units. Range. Air handling unit with high available static pressure. NEW Eco-Design Filter. V3000 control Fresh air management

UTA STANDARD. Ductable units. Range. Air handling unit with high available static pressure. NEW Eco-Design Filter. V3000 control Fresh air management Ductable units NEW Eco-Design Filter Air handling unit with high available static pressure V3000 control Fresh air management The range of air handling units is designed for suspended ceiling heating and

More information

TD-SILENT Series (160 to 1000 models)

TD-SILENT Series (160 to 1000 models) IN-LINE MIXED LOW DUT ANS ultra-quiet Series (1 to models) Low profile Mixed-flow fans with sound-absorbent insulation. Extremely quiet. ertified of Approval Noise Abatement Society (TD-3, TD-, TD-8 and

More information

FS5BD-KA Series High Efficiency Air Conditioner 13+ SEER Residential System Ton Capacity

FS5BD-KA Series High Efficiency Air Conditioner 13+ SEER Residential System Ton Capacity TECHNICAL SPECIFICATIONS FS5BD-KA Series High Efficiency Air Conditioner 13+ SEER Residential System 1.5-5 Ton Capacity The FS5BD Series of air conditioners offers exceptional performance. The unit, when

More information

GQ4 Series TECHNICAL SPECIFICATIONS. Three Phase Single Packaged Heat Pump (12 SEER) GQ4SC-036C GQ4SC-048C GQ4SC-060C FEATURES AND BENEFITS

GQ4 Series TECHNICAL SPECIFICATIONS. Three Phase Single Packaged Heat Pump (12 SEER) GQ4SC-036C GQ4SC-048C GQ4SC-060C FEATURES AND BENEFITS TM TECHNICAL SPECIFICATIONS GQ4 Series Three Phase Single Packaged Heat Pump (12 SEER) GQ4SC-036C GQ4SC-048C GQ4SC-060C The GQ4 Series single packaged units are high efficiency self contained cooling and

More information

5/8 (16) DIA. MOUNTING HOLES TYP [4] PLACES. SEE NOTE #3 ACCESS PANEL BOTH SIDES 2 1/2 (64) Unit Size Fan Size L W H C D E F G J (508) (406) 25 (635)

5/8 (16) DIA. MOUNTING HOLES TYP [4] PLACES. SEE NOTE #3 ACCESS PANEL BOTH SIDES 2 1/2 (64) Unit Size Fan Size L W H C D E F G J (508) (406) 25 (635) LOER OILS, orizontal and ertical imensional Information TOP N SIE IES (RR 3) LOER OILS 9/ (4) I. MOUNTING OLES TYP [4] PLES. ITOUT SE RIL NOTES:. Provide sufficient clearance to permit access to controls

More information

LOW AIR / DUAL THROW UNIT COOLER. EPC - High & Medium Temperature Application Capacity: 2.2kW to 19.2kW

LOW AIR / DUAL THROW UNIT COOLER. EPC - High & Medium Temperature Application Capacity: 2.2kW to 19.2kW G4 LOW AIR / DUAL THROW UNIT COOLER EPC - High & Medium Temperature Application Capacity: 2.2kW to 19.2kW DEPC - High & Medium Temperature Application Dual Air Throw Capacity: 4.4kW to 38.4kW Low Noise

More information

TECHNICAL GUIDE. Echelon MODELS: FC8S GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES

TECHNICAL GUIDE. Echelon MODELS: FC8S GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES TECHNICAL GUIDE Echelon MODELS: FC8S GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE NATURAL GAS 40-130 MBH INPUT EFFICIENCY RATING CERTIFIED DESCRIPTION These high efficiency, dedicated

More information

GQ4SD Series. Single Packaged Heat Pump 13 SEER TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

GQ4SD Series. Single Packaged Heat Pump 13 SEER TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS TM TECHNICAL SPECIFICATIONS GQ4SD Series Single Packaged Heat Pump 13 SEER The GQ4 Series single packaged units are high efficiency self contained cooling and heating units that can be installed on a roof

More information

TD-SILENT range, the quietest fans in the world in their class

TD-SILENT range, the quietest fans in the world in their class IN-LIN MIXD LOW DUT NS ULTR-QUIT Series NW 44682 314 Low profile Mixed-flow fans with sound-absorbent insulation. xtremely quiet. Manufactured in plastic material, with a specifically designed internal

More information

Compressed Air Filtration

Compressed Air Filtration AG / SG / HD Adsorption Filter MAIN FEATURES & BENEFITS: Activated carbon filter with integrated particle filter for the retention of oil vapours, hydrocarbons and odours as well as particles from compressed

More information

A I R H A N D L E R S CB26UH-R. MERIT Series R-22 - Upflow / Horizontal P R O D U C T S P E C I F I C AT I O N S

A I R H A N D L E R S CB26UH-R. MERIT Series R-22 - Upflow / Horizontal P R O D U C T S P E C I F I C AT I O N S P R O D U C T S P E C I F I C AT I O N S A I R H A N D L E R S CB6UH-R MERIT Series R- - Upflow / Horizontal Bulletin No. 1067 April 01 Supersedes January 01 Nominal Capacity - 1.5 to 5 Tons Optional Electric

More information

Compressed Air Filtration

Compressed Air Filtration DF dsorption Filter MIN FETURES & BENEFITS: ctivated carbon filter with integrated particle filter for the retention of oil vapours, hydrocarbons and odours as well as particles from compressed air or

More information

TECHNICAL GUIDE AFFINITY MODELS: PS8 GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES

TECHNICAL GUIDE AFFINITY MODELS: PS8 GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES TECHNICAL GUIDE AFFINITY MODELS: PS8 GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE NATURAL GAS 40-130 MBH INPUT EFFICIENCY RATING CERTIFIED DESCRIPTION These high efficiency, dedicated

More information

AC Commercial Fans Edition. ErP ready

AC Commercial Fans Edition. ErP ready AC Commercial Fans 213 Edition ErP ready AC Commercial Fans Axair Fans UK Ltd / 1782 34943 About Axair Fans UK Axair is an independent industrial fan manufacturer and distributor. What we offer : Application

More information

TO BE USED ONLY BY AUTHORISED PERSONNEL

TO BE USED ONLY BY AUTHORISED PERSONNEL SERVICE MANUAL for BOSTON (MG 3000 STD) SANTA FE (CALGARY, MG 3000 FLS) & ODESSA (PG 3000) GAS FIRES TO BE USED ONLY BY AUTHORISED PERSONNEL PART No 588402 Issue E Nov. 2001 CONTENTS TROUBLESHOOTING Page

More information

PGC COMMERCIAL PACKAGED GAS/ELECTRIC

PGC COMMERCIAL PACKAGED GAS/ELECTRIC PGC COMMERCIAL PACKAGED GAS/ELECTRIC PRODUCT SPECIFICATIONS 7½ TO 10 TON 10.3 EER COOLING CAPACITY 86,000-116,000 BTU/H HEATING CAPACITY 193,000-225,000 BTU/H The Goodman PGC Commercial Packaged Gas/Electric

More information

Replacement Parts List

Replacement Parts List Replacement Parts List PARTS & SERVICE DEPARTMENT Nashville, Tennessee 877-554-5544 Fax: 615-882-2918 parts_team@lochinvar.com www.lochinvar.com Copper-Fin II Boilers Water Heaters CH CF 992-2072 50 17

More information

Fan coil units. Why choose Daikin fan coil units? 540 Products overview 542. Options & accessories 560. Round flow cassette 544 FWC-BT/BF 544

Fan coil units. Why choose Daikin fan coil units? 540 Products overview 542. Options & accessories 560. Round flow cassette 544 FWC-BT/BF 544 Fan coil units Why choose Daikin fan coil units? 540 Products overview 542 Round flow cassette 544 FWC-BT/BF 544 4-way blow ceiling mounted cassettes 545 FWG-AT/AF 545 FWF-BT/BF 546 FWF-CT 547 Floor standing

More information

LVDT/HC PILOT BURNER. External raw gas pilot burner

LVDT/HC PILOT BURNER. External raw gas pilot burner 4-22.4-1 LVDT/HC PILOT URNER External raw gas pilot burner Stable pilot flame in combination with MXON IRFLO LV, HC, DELT-TE and COMUSTIFUME burners Rugged design urns natural gas, propane and LPG Suitable

More information

42AM. Air heaters. product selection. the best solution for heating large spaces. ensures buildings warm up ultra-fast

42AM. Air heaters. product selection. the best solution for heating large spaces. ensures buildings warm up ultra-fast product selection the best solution for heating large spaces ensures buildings warm up ultra-fast excellent diffusion via patented JET+ double deflection technology ir heaters 4M Translation of the original

More information

80% A.F.U.E. DOWNFLOW GAS FURNACES

80% A.F.U.E. DOWNFLOW GAS FURNACES FORM NO. G66-496 REV. 5 Supersedes Form No. G66-496 Rev. 4 RGLS- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] (U.S. & Canadian Models) 80% A.F.U.E. DOWNF GAS FURNACES The

More information

SRX R. Remediation Pumps. Simply Reliable

SRX R. Remediation Pumps. Simply Reliable SRX R Remediation Pumps Simply Reliable The SRX pump is based on a simple, innovative design and built with fi eld-proven components. The result: a reliable pump to meet the demands of your remediation

More information

FW and FL Fan-Coil Units Floor-Mounted, Vertical STANDARD AND LOW PROFILE

FW and FL Fan-Coil Units Floor-Mounted, Vertical STANDARD AND LOW PROFILE FW and FL Fan-Coil Units Floor-Mounted, Vertical STANDARD AND LOW PROFILE Low Power Consumption, Accessible, & FW and FL Fan-Coil Design Features Owners Owners can choose between a standard height (FW)

More information

Direct-Fired Heating, Ventilation and Pressurization Systems

Direct-Fired Heating, Ventilation and Pressurization Systems 2000-Series irect-ired Heating, Ventilation and Pressurization Systems imension and Selection uide 1.800.536.3461 www.rapidengineering.com N: 100% Outside ir Only 2000-Series Selection uide M (m 3 /h)

More information

Spare parts list SI RSF 22/04/

Spare parts list SI RSF 22/04/ Spare parts list 6720620020 25SI RSF 22/04/2009 6720620020 1 22/04/2009 6720620020 2 22/04/2009 6720620020 3 Spare parts list 1 Pump / Hydraulic assy 22/04/2009 6720620020 4 Pos description S-Nr ordering

More information

Low Air Process Room. Chiller Series. EPC - High & Medium Temperature Application Capacity: 2.2kW to 19.2kW

Low Air Process Room. Chiller Series. EPC - High & Medium Temperature Application Capacity: 2.2kW to 19.2kW G4 Low Air Process Room Chiller Series EPC - High & Medium Temperature Application Capacity: 2.2kW to 19.2kW DEPC - High & Medium Temperature Application Dual Air Throw Capacity: 4.4kW to 38.4kW Low Noise

More information

50RHR/50RVR/50RDR HORIZONTAL, VERTICAL AND DOWNFLOW WATER SOURCE HEAT PUMPS

50RHR/50RVR/50RDR HORIZONTAL, VERTICAL AND DOWNFLOW WATER SOURCE HEAT PUMPS 0-1 0/0V/0 IZ, VI WW W IZ 1 / 2 to I VI 3 / 4 to I WW 1 1 / 4 to I II II I opyright 2000 arrier orporation yracuse, ew York 13221 orm 0-1 eplaces: ew rinted in... 2-00 atalog o. 1-170 ate: upersedes: 0/0V/0

More information

SUPPLY ROUND DIFFUSERS TABLE OF CONTENTS ROUND DIFFUSERS. M-2 Excellence in Air Distribution MODELS RM1/5RM1/RM2/5RM2/RM4/5RM4/RA2/RA4

SUPPLY ROUND DIFFUSERS TABLE OF CONTENTS ROUND DIFFUSERS. M-2 Excellence in Air Distribution MODELS RM1/5RM1/RM2/5RM2/RM4/5RM4/RA2/RA4 SUPPLY OUN IFFUSES TBLE OF CONTENTS OUN IFFUSES 1/51 These supply ceiling diffusers discharge horizontally only. They feature three cones with two position settings to control room air induction. 2/52/2

More information

GAS FURNACES CLASSIC SERIES SUPER QUIET 80 80% A.F.U.E. DOWNFLOW GAS FURNACES

GAS FURNACES CLASSIC SERIES SUPER QUIET 80 80% A.F.U.E. DOWNFLOW GAS FURNACES FORM NO. G11-487 REV. 1 Supersedes Form No. G11-487 Rev. 8 GAS FURNACES RGLN- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] (U.S. & Canadian Models) Annual Fuel Utilization

More information

@Perkins. Technical Data. 400 Series 403D-11G. ElectropaK

@Perkins. Technical Data. 400 Series 403D-11G. ElectropaK Technical Data @Perkins 400 Series 403D-11G ElectropaK Basic technical data Number of cylinders.................................................... 3 Cylinder arrangement....................................

More information

VAV RETROFIT/BYPASS TERMINAL UNITS TABLE OF CONTENTS RETROFIT/BYPASS TERMINAL UNITS. E-2 Excellence in Air Distribution MODEL RVE MODEL KLB MODEL SVE

VAV RETROFIT/BYPASS TERMINAL UNITS TABLE OF CONTENTS RETROFIT/BYPASS TERMINAL UNITS. E-2 Excellence in Air Distribution MODEL RVE MODEL KLB MODEL SVE TALE OF CONTENTS RETROFIT/YPASS TERMINAL UNITS RVE This retrofi t terminal unit is designed to convert high pressure mechanical constant volume systems to low pressure variable volume systems and also

More information

Model ZW204 Non-Modulating Float Valve

Model ZW204 Non-Modulating Float Valve Model Z04 Non-Modulating loat Valve pplication The Zurn ilkins Model Z04 Non-Modulating loat Operated ontrol Valve is designed to be either fully open or fully closed in response to the position of the

More information

Innovative Reliability for Mobile Power Applications

Innovative Reliability for Mobile Power Applications COMMERCIAL MOBILE GENERATORS Innovative Reliability for Mobile Power Applications Cummins Onan Commercial Mobile Generators The Cummins Onan mission is simple: Design and create the best, most innovative

More information

FCC DUCTABLE AIR TREATMENT UNIT

FCC DUCTABLE AIR TREATMENT UNIT FCC DUCTBLE IR TRETMENT UNIT DUCTBLE IR TRETMENT UNIT FCC 7 different sizes 3, 4 and 6 row coils 2 or 4 pipe system Horizontal installation ductable air treatment unit FCC series The ductable air treatment

More information

Portable Filter Carts. Models 5MFP & 10MFP with Modufl ow and Intelli-Cart

Portable Filter Carts. Models 5MFP & 10MFP with Modufl ow and Intelli-Cart Models 5MFP & 10MFP with Modufl ow and Intelli-Cart 174 Applications Filtering new fluid before putting into service Transferring fluid from drums or storage tanks to system reservoirs Conditioning fluid

More information

Warm. DFC Direct Fired Gas Heating System. Applied Air. Keeps You. Technical Guide for: Outdoor Mounted Units To 100,000 CFM And 14M BTUH

Warm. DFC Direct Fired Gas Heating System. Applied Air. Keeps You. Technical Guide for: Outdoor Mounted Units To 100,000 CFM And 14M BTUH TGDFC-6 DFC Direct Fired Gas Heating System Technical Guide for: Outdoor Mounted Units To 0,000 CFM And 14M BTUH Applied Air Keeps You Warm Featuring the Patented AdaptAire controlled Circulation System

More information

GAS FURNACES ACHIEVER SERIES SUPER QUIET % A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES

GAS FURNACES ACHIEVER SERIES SUPER QUIET % A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES FORM NO. G22-485 REV. 4 Supersedes Form No. G22-485 Rev. 3 GAS FURNACES UGPN- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] (U.S. & Canadian Models) Annual Fuel Utilization

More information

TGIF-3. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You.

TGIF-3. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You. TGIF-3 Indirect Fired Heating Systems Technical Guide for: IF Indoor Installations IFW Outdoor Installations Applied Air Keeps You Warm Indirect Fired Heating Systems Technical Guide In the business of

More information

Rheem Value Series Downflow Gas Furnace

Rheem Value Series Downflow Gas Furnace THIS MODEL 80.0% 78% 82% 88% 97% Air Gas Furnaces Rheem Value Series Downflow Gas Furnace RGLS- Series 80% A.F.U.E. Input Rates 50-150 kbtu ENER UIDE Annual Fuel Utilization Efficiency - AFUE MID A.F.U.E.

More information

AH / AV. Advanced Series Unit Heaters AH / AV. Ruffneck

AH / AV. Advanced Series Unit Heaters AH / AV. Ruffneck The Ruffneck Advanced Series heaters are designed for rugged industrial applications and are available in 37 models from 6,000 to 1,,000 Btu/hr With a maximum operating pressure and temperature rating

More information

GREENOx BT LOW RETURN TEMPERATURE DUAL BT WITH TILED BOILERS. GREENOx BT COND LOW RETURN TEMPERATURE WITH CONDENSER

GREENOx BT LOW RETURN TEMPERATURE DUAL BT WITH TILED BOILERS. GREENOx BT COND LOW RETURN TEMPERATURE WITH CONDENSER TECHNICAL MANUAL GREENOx BT LOW RETURN TEMPERATURE DUAL BT WITH TILED BOILERS GREENOx BT COND LOW RETURN TEMPERATURE WITH CONDENSER GREENOx/GREENOx.e/K WITH THREE GAS PASSES DUAL GRX/DUAL GRX.e THREE GAS

More information

INDEX. Chapter1 0. air master. Round Ceiling Diffusers

INDEX. Chapter1 0. air master. Round Ceiling Diffusers air master Chapter1 0 INDEX A. Round ceiling diffusers 1. Fixed round ceiling diffuser...: ARDF...10.1 2. Round ceiling diffuser with adjustable pattern...: ARD...10.2 Standard sizes...10.3 Air pattern...10.3

More information

AHPHX Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology

AHPHX Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology HANDLERS LTD AHPHX Compact Heat Recovery Air Handling Unit 1262 Acoustic Testing Laboratory College of Science & Technology BIM & REVIT Engineering Solutions The Company Air Handlers has been trading since

More information

Sound Attenuated Level 2. Enclosures. Features. Enclosures kva Range

Sound Attenuated Level 2. Enclosures. Features. Enclosures kva Range Sound Attenuated Level 2 24 220 kva Range The sound attenuated Level 2, factory installed enclosures incorporate internally mounted critical level silencers. They are the premium enclosure offering for

More information

AC Single & Three-Phase Direct Drive Fans

AC Single & Three-Phase Direct Drive Fans Single & Three-Phase irect rive ans 96 899 99s or over a century... istory Originally formed over years ago as part of the US based Torin orporation, and then established as a U subsidiary in 96; Torin-Sifan

More information

CUH Series. Cabinet Unit Heaters HEAT TRANSFER DIVISION

CUH Series. Cabinet Unit Heaters HEAT TRANSFER DIVISION UH Series abinet Unit Heaters TM HEAT TRANSFER DIVISION UH SERIES ABINET UNIT HEATERS ROUGHING IN DIMENSIONS TYPIAL ARRANGEMENTS B B 1 1/" (38) REESSING FRAME B 1 1/" (38) REESSING FRAME FULLY EXPOSED

More information

KAESER FILTER. KF F350 to F3360 Series Reliable purity for high flow rates Flow rate 35.4 to m³/min, Pressure 2 to 16 bar COMPRESSORS

KAESER FILTER. KF F350 to F3360 Series Reliable purity for high flow rates Flow rate 35.4 to m³/min, Pressure 2 to 16 bar COMPRESSORS COMPRESSORS KAESER FILTER KF F350 to F3360 Series Reliable purity for high flow rates Flow rate 35.4 to 336.3 m³/min, Pressure 2 to 16 bar www.kaeser.com KF F350 to F3360 series Clean compressed air at

More information

Specifications of MAXON VALUPAK burners for 50 Hz operation

Specifications of MAXON VALUPAK burners for 50 Hz operation 1-1.5-7 Specifications of MAXON VALUPAK burners for 50 Hz operation Capacity data in kw Gross heating value = 10.9 kwh/m 3 (st), d = 0.6. All figures are for balanced - 0 mbar - duct pressure VALUPAK size

More information