LED FLOOD LIGHT SOLUTIONS Harsh and Hazardous Products

Size: px
Start display at page:

Download "LED FLOOD LIGHT SOLUTIONS Harsh and Hazardous Products"

Transcription

1 LED FLOOD LIGHT SOLUTIONS Harsh and Hazardous Products

2 Ex- LED Lighting and Control Switches

3 KILLARK LED FLOOD LIGHTS H A Z LO C INDEX PRODUCT PAGE NO. NEMA 4 (or 4X or IP66) Class I, Div. 2 / Zone 2 Class I, Zone 2 Ex nr Class II / III Div. I Class II / III Div. 2 Class I, Div. 1 C, D / Zone 1 Class I, Div. 1 A, B, C, D / Zone 1 IECEx Zone 1 ATEX Zone 1 IECEx Zone 2 ATEX Zone 2 KFLC Series X X X X KFL Series X X X X X X KFLH Series X X X X X X KF1L Series X X X X X X X X X Lighting Switches SEE SOFTWARE FOR LATEST LED PHOTOMETRY i

4 KILLARK Z A H LO C KFLC SERIES COMPACT FLOOD INTRODUCTION & LOGIC LED TECHNOLOGY Class I, Div. 2, Groups A,B,C,D Class I, Zone 2, Groups IIC, IIB, IIA Class II, Div. 1 & 2, Groups E,F,G Class III NEMA 4X File LR11713 FEATURES-SPECIFICATIONS Applications LED Compact Floods are designed for installations where moisture, dirt, dust, corrosion and vibration may be present, or NEMA 3 and 4X areas where wind, water, snow or high ambients can be expected. They can be used in locations made hazardous by the presence of flammable vapors or gases or combustible dusts as defined by the NEC. Typical applications include spot lighting or walkways in manufacturing plants, and certain chemical and petrochemical processing facilities, sewage treatment plants, off-shore and dockside installations, garages and storage facilities Compliances UL-8750 for LED lighting ANSI/UL 1598 (A) UL-844 Standard for lighting fixtures for hazardous locations, Class I, Division 1; Class II, Division 1; Class III CSA C22.2 no. 137-M1981 electric luminairies for use in hazardous locations Enclosed and gasketed NEMA 3, 4X, IP66 Materials LED Body and lens frame corrosion resistant copper-free aluminum alloy with baked powder epoxy/polyester finish, electrostatically applied for complete, uniform corrosion protection All external hardware stainless steel Thermal shock and impact resistant extra heavy-duty glass lens High temperature silicone gasketing Trunnion heavy gauge galvanized steel with painted finish LED Flood Features and Standards One 3/4 NPT hub & R-21 3/4 x 1/2 reducer is standard Crisp White Light for Excellent Color Rendering Chromaticity 5000 K (CCT); approx. 70 CRI Energy Savings High lumens per watt Long Life 100,000+ maintenance free hours to 70% initial lumens Ambient suitability -40 C to 55 C Instant On Including after power interruption Solder-LESS LED Board Connections Vibration Resistant LM80-08* Measurement of lumen maintenance for LED light sources LM79-08* Certified Absolute Photometry, including Chromaticity Color for Solid State Lighting L70 Values Industry Nomenclature for Hours of use to 70% of initial Lumens TM-21* & calculated Patented Fixture Design KFLC with Slipfitter mount on 2 pipe Dark Sky Visor KFLC-DARK * LM-xx & TM-xx are illumination Engineering Society Standards designed to promote uniformity in testing procedures among test labs and manufacturers. For more information go to Catalog Number Logic KFLC X X KFLC - Series Constant LED Wattage 15-15W 30, 27 or 34 voltage codes 18-18W 30, 27 or 34 voltage codes 20-20W 30, 27 or 34 voltage codes 23-23W 30, 27 or 34 voltage codes 25-25W 30, 27 or 34 voltage codes 30-30W 30 voltage code VAC 35-35W 30 voltage code VAC 40-40W 30 voltage code VAC 45-45W 30 voltage code VAC 50-50W 30 voltage code VAC Voltage VAC 50/60Hz VDC input Options LY- Less Yoke for Wall Mount F- Single Fuse j FF- 2 Fuses j SP- Surge Protection TBL- Terminal Blocks Looping QD- QuickDisconnect D75- Dual 3/4 threaded NPT entry M25- Single M25 Slip-hole Entry D25- Two M25 Slip-hole Entry M20- Single M20 Slip-hole Entry D20- Dual M20 Slip-hole Entry VDC input; VAC (15-23W only) PL- Polycarbonate Lens j Fusing not for Canadian Marine Installations 2

5 KILLARK KFLC SERIES H A Z LO C COMPACT FLOOD ORDERING & TECHNICAL DATA ORDERING INFORMATION AND AMBIENT SUITABILITY C1D2 C1D2 C2D1 L70 CATALOG NO. WEIGHT LBS./KG WATTS VOLTAGE AMPS LUMENS 40 C 55 C 40 C 55 C 40 C 55 C TM-21 CALCULATED KFLC VDC KFLC VAC KFLC VDC KFLC VDC KFLC VAC KFLC VDC KFLC VDC KFLC VAC KFLC VDC KFLC VDC / 4.31 KFLC VAC KFLC VDC KFLC VDC KFLC VAC KFLC VDC KFLC Extra high lumen per watt LED s * KFLC 30-50w Lumens are LM-79 absolute photometry W are calculated based on driver output current. ** All wattages are available as 30 voltage code VAC T6 T6 T4 T3B T4A T4A T6 T6 T4 T3B T4A T4A T6 T6 T4 T3B T4A T4A T6 T6 T4 T3B T4A T4A T6 T6 T4 T3B T4A T4A T6 T6 T4 T3B T4A T4A KFLC T6 T6 T4 T3B T4A T4A KFLC VAC T6 T6 T4 T3B T4A T4A KFLC T6 T6 T4 T3B T4A T4A KFLC T6 T6 T4 T3B T4A T4A Dimensions ** TM-21 based values require very long duration testing. IES TM-21 official reported is based on at 8,000 to 10,000 hours of LED chip manufacturer s LM-80 Testing at printing. Trunnion Mounting Detail SLIPFITTER CROSS ARM MOUNT WALL/PIPE BRACKET WALL BRACKET 4041 TENON FITTING CATALOG NUMBER KFL MOUNTS AND ACCESSORIESj DESCRIPTION KFLC-DARKk Reflector for field addition - No uplight at 45 to 70 KFLCG KFLC-DOORk Guard Replacement Door Assembly NWP-HUBA 3/4 Aluminum Hub; Replacement or Additional (Max. 4) VMSC10l Safety Cable (through yoke) Steel Slipfitter for 2 Pipe (2-3/8 o.d.) Tenon. Slips 3.75 Over Pipe. Heavy Duty Cast-Iron Crossarm Fitting for Horizontal Trunnion Heavy Duty Wall Mount and/or Pipe Clamp Fitting Clamps 2 Pipe (2-3/8 o.d.) Through 2-1/2 Pipe (2-7/8 o.d.) Heavy Duty Steel Wall Bracket. (Must be with Crossarm Fitting) Heavy Duty Steel Wall Bracket 2 Pipe (2-3/8 o.d.) Tenon Fitting. j Fittings available to adapt trunnion mount floodlights to crossarms, poles and walls. Must be ordered separately. k Drop limit 1. Attaches to luminaire cable provision and to mounting structure. l Designed to eliminate uplight when aimed at 70. Front Side SEE SOFTWARE FOR LATEST LED PHOTOMETRY 3

6 KILLARK Z A H LO C KFL SERIES FEATURES-SPECIFICATIONS Applications LED Floods are designed for installations where moisture, dirt, dust, corrosion and vibration may be present, or NEMA 3 and 4X areas where wind, water, snow or high ambients can be expected. They can be used in locations made hazardous by the presence of flammable vapors or gases or combustible dusts as defined by the NEC. Typical applications include manufacturing plants, and certain chemical and petrochemical processing facilities, sewage treatment plants, off-shore and dockside installations, garages and storage facilities. Compliances UL-8750 for LED lighting ANSI/UL 1598(A) UL-844 Standard for lighting fixtures for hazardous locations, Class I, Division 2; Class II, Divisions 1 and 2; Class III CSA C22.2 no. 137-M1981 electric luminairies for use in hazardous locations Enclosed and gasketed NEMA 3, 4X IP66 IEX suffix Zone 2/21 to IEC , , Standards Materials Body, end caps and lens frame corrosion resistant copper-free aluminum alloy with baked powder epoxy/polyester finish, electrostatically applied for complete, uniform corrosion protection All external hardware - stainless steel Thermal shock and impact resistant glass lens High temperature silicone gasketing C1D2 FLOOD INTRODUCTION & LOGIC LED Trunnion heavy gauge galvanized steel with painted finish LED Flood Features and Standards Crisp White Light for Excellent Color Rendering - Chromaticity 5000K (CCT); approx. 70 CRI Energy Savings - High lumens per watt Long Life - to 100,000+ maintenance free hours to 70% initial lumens Ambient suitability -50 C to 55 C up to 125Wk Instant On - Including after power interruption World Voltage VAC 50/60Hz Solder-LESS LED Board Connections - Vibration Resistant LM80-08* Measurement of lumen maintenance for LED light sources LM79-08* Certified Absolute Photometry, including Chromaticity Color for Solid State Lighting L70 Values - Industry Nomenclature for Hours of use to 70% of initial Lumens - TM-21* & Calculated Supplemental surge protection included as standard for AC models only Class I, Div. 2, Groups A,B,C,D Class II, Div. 1&2, Groups EFG Class III Suitable for wet locations Marine Rated (US Only) NEMA 3, 4X IP66 IEC Ex Rated model (w/iex suffix) Zone 2 and Zone 21 areas Ex na IIC T6 T3, Gc Ex tb IIIC T160 C Db Tamb -50 C <Ta<+55 C, IP66 IECEx Certificate CSA X ATEX CML 14ATEX3087/4088 PATENTED LUMINAIRE DESIGN File LR11713 KFL with Slipfitter mount on 2 pipe * LM-xx & TM-xx are illumination Engineering Society Standards designed to promote uniformity in testing procedures among test labs and manufacturers. For more information go to IEX Units include Qty. 3 6mm terminals plus external ground as standard Catalog Number Logic KFL XX KFL - Series Constant Fixture Wattage W W W W W W W W W W W Consult website for current list of approved luminaires Dark Sky Visor KFL-DARK Voltage VAC 50/60Hz VAC 60Hz (85W to 125W models)k VDC (85W to 125W models) Options Construction Note: Models with dual metric entries are tapped with one plugged and the standard 3/4 NPT entry will be plugged. PL - Polycarbonate Lens F - Single Fusej j Fusing not for Canadian or Marine Installations FF - Double Fusej k 347V-480V +40 C Max TBL - Terminal Blocks Looping (Std. w/iex) P1-120V Photocell, factory installed P2-208V-277V Photocell, factory installed P3-347V Photocell, factory installed QD - Quick Disconnect D20-2x M20 entries D25-2x M25 entries D75-2 x 3/4 NPT SY SS Yoke IEX - IECEx & ATEX includes TBL and External Ground (to 125W) 4

7 KILLARK KFL SERIES H A Z LO C CATALOG NO.j KFL06030 C1D2 FLOOD ORDERING INFORMATION & TECHNICAL DATA ORDERING INFORMATION AND AMBIENT SUITABILITY WEIGHT LBS./KG C1D2m C1D2m SIMULTANEOUS j Cat. nos. are VAC models, see logic for V. k Amperage measured at 120VAC; 277VAC calculated l Extra high Lumens per Watt LED models m Use 75 minimum Supply C Ambient; C Ambient n First number is lens temperature under 25mm layer of dust; Second number is lens temp. for dust cloud. C2D1m IEC ZONE 2 m IEC ZONE 21n AMPS WATTS VOLTAGE LUMENSl 40 C 55 C 40 C 55 C 40 C 55 C 40 C 55 C 40 C 55 C TM-21 CALCULATED jk VAC T6 T5 T3C T3C T3C (EFG) T3C (EFG) T6 T KFL VAC T6 T5 T3C T3C T3C (EFG) T3C (EFG) T6 T KFL VAC T6 T5 T3C T3C T3C (EFG) T3C (EFG) T6 T KFL VAC KFL VAC KFL VDC KFL VAC KFL VAC KFL VDC KFL VAC / KFL VAC KFL VDC KFL VAC KFL VAC KFL VDC KFL VAC KFL VAC KFL VDC T6 T5 T3C T3C T3C (EFG) T3C (EFG) T6 T T6 T5 T3C T3C T3C (EFG) T3C (EFG) T6 T T4A T4A T3C T3C T3C (EFG) T3C (EFG) T4 T T6 T5 T3C T3C T3C (EFG) T3C (EFG) T6 T T6 T5 T3C T3C T3C (EFG) T3C (EFG) T6 T KFL VAC T5 - T3C - T3C (EFG) KFL VAC T5 - T3C - T3C (EFG) KFL VAC T5 - T3C - T3C (EFG) Dimensions [450.9] [377.8] L [287.6] Slipfitter Cross Arm Mount Wall/Pipe Bracket Wall Bracket 4041 Tenon Fitting KFL MOUNTS AND ACCESSORIESj CATALOG NUMBER DESCRIPTION Steel Slipfitter for 2 Pipe (2-3/8 o.d.) Tenon. Slips 3.75 Over Pipe. Heavy Duty Cast-Iron Crossarm Fitting for Horizontal Trunnion Heavy Duty Wall Mount and/or Pipe Clamp Fitting Clamps 2 Pipe (2-3/8 o.d.) Through 2-1/2 Pipe (2-7/8 o.d.) Heavy Duty Steel Wall Bracket. (Must be with Crossarm Fitting) Heavy Duty Steel Wall Bracket 2 Pipe (2-3/8 o.d.) Tenon Fitting. Uses with. KFLGo VMSC10k KFL-DARKlo KFL-DOOR KFL-DOOR2mn Wire Guard, 316 Stainless Steel (not used with KFL-DARK) 10 Stainless Steel Safety Cable with loop grip Dark Sky Visor, White Painted Aluminum (not used with KFLG) Replacement Door and Lens Assembly (for units w/o internal reflectors) Replacement Internal Reflector and Lens Assembly j Fittings available to adapt trunnion mount floodlights to crossarms, poles and walls. Must be ordered separately. k Drop limit 1. Attaches to luminaire cable provision and to mounting structure. l Designed to eliminate uplight when aimed at 45. m Only for models factory supplied with internal reflector. n Not backward compatible with units originally shipped without internal reflector. o KFLG and KFL-DARK cannot be used together..531 DIA. (13) 3-1/8 (79) Front Trunnion Mounting Detail 5.22 [132.7] 2.00 [50.8] Side 8.41 [213.5] [357.3] SEE SOFTWARE FOR LATEST LED PHOTOMETRY 5

8 KILLARK Z A H LO C KFLH SERIES FEATURES-SPECIFICATIONS Applications LED Floods are designed for installations where moisture, dirt, dust, corrosion and vibration may be present, or NEMA 3 and 4X areas where wind, water, snow or high ambients can be expected. They can be used in locations made hazardous by the presence of flammable vapors or gases or combustible dusts as defined by the NEC. Typical applications include manufacturing plants, and certain chemical and petrochemical processing facilities, sewage treatment plants, off-shore and dockside installations, garages and storage facilities. Compliances UL-8750 for LED lighting ANSI/UL 1598(A) UL-844 Standard for lighting fixtures for hazardous locations, Class I, Division 2; Class II, Divisions 1 and 2; Class III CSA C22.2 no. 137-M1981 electric luminairies for use in hazardous locations Enclosed and gasketed NEMA 3, 4X IP66 Materials Body and lens frame corrosion resistant copper-free aluminum alloy with baked powder epoxy/polyester finish, electrostatically applied for complete, uniform corrosion protection All external hardware stainless steel Thermal shock and impact resistant glass lens (Polycarbonate available) High temperature silicone gasketing Trunnion heavy gauge 316 stainless steel C1D2 FLOOD INTRODUCTION & LOGIC LED LED Flood Features and Standards Crisp White Light for Excellent Color Rendering Chromaticity 5000K (CCT); approx. 70 CRI Energy Savings High lumens per watt Long Life to 100,000+ maintenance free hours to 70% initial lumens Ambient suitability -40 C to 55 C up to 250Wk to -50 C for non-hazardous applications Instant On Including after power interruption World Voltage VAC 50/60Hz Solder-LESS LED Board Connections Vibration Resistant LM80-08* Measurement of lumen maintenance for LED light sources LM79-08* Certified Absolute Photometry, including Chromaticity Color for Solid State Lighting L70 Values Industry Nomenclature for Hours of use to 70% of initial Lumens TM-21* & Calculated Class I, Div. 2, Groups A, B, C, D Class I, Zone 2, IIC, IIB, IIA Class II, Div. 1 & 2, Groups E, F, G Class III Suitable for wet locations Marine Rated (US only) NEMA 3, 4X IP66 IEC Ex Rated Model (w/ IEX suffix) Zone 2 and Zone 21 areas Ex na IIC T6 T3, Gc Ex tb IIC T105 C Db Tamb -50 C < Ta < +55 C, IP66 IECEx Certificate QPS ATEX Certificate CML 15ATEX4079X (na) & CML 15ATEX3080X (tb) PATENTED LENS and REFLECTOR DESIGN KFLH Luminaire Catalog Number Logic KFLH XX KFLH - Series Constant Fixture Wattage W W W W W W Dark Sky Visor KFLH-DARK Voltage VAC 50/60Hz VAC 60Hz (170W to 250W)k VDC (170W to 250W) Options PL - Polycarbonate Lens F - Single Fusej FF - Double Fusej TBL - Terminal Blocks Looping P1-120V Photocell, factory installed P2-208V-277V Photocell, factory installed P3-347V Photocell, factory installed QD - Quick Disconnect D20-2x M20 entries IEX - IEXEx includes TBL & External ground * LM-xx & TM-xx are illumination Engineering Society Standards designed to promote uniformity in testing procedures among test labs and manufacturers. For more information go to Supplemental surge protection included as standard for AC models only Construction Note: Standard with two 3/4 NPT entries with one plugged Models for dual metric entries have slip holes with metric locknuts and certified blanking plugs j Fusing not for Canadian or Marine Installations k 347V-480V +40 C Max 6

9 KILLARK KFLH SERIES H A Z LO C C1D2 FLOOD ORDERING INFORMATION & TECHNICAL DATA ORDERING INFORMATION AND AMBIENT SUITABILITY C1D2 (C1Z2) C1D2 SIMULTANEOUS C2D1 L70 CATALOG NO. WEIGHT LBS./KG WATTS VOLTAGE AMPS LUMENS 40 C 55 C 40 C 55 C 40 C 55 C TM-21 CALCULATED KFLH VAC KFLH VAC KFLH VDC KFLH VAC KFLH VAC KFLH VDC KFLH VAC / 11.3 KFLH VAC KFLH VDC KFLH VAC KFLH VAC KFLH VDC j Cat. Nos. are 120 through 277VAC 50/60Hz; see logic for V or VDC input k Amperage measured at 120VAC; 277VAC calculated l Extra High Lumens per Watt LED Models m Use 75 C Supply 40 C Ambient; 90 C 55 C Ambient n 55 C only for 170W through 250W at VAC 50/60Hz or VDC; not 480VAC o For Dust Applications, limit aiming angle between 120 and -120 to minimize buildup - see figure at right p L70 is time in hours to 70% of initial lumens remaining. TM-21 based values require very long duration testing and is denoted official reported and is based on at least 6,000 minimum, to 12,000 hours testing (at time of printing). Calculated values by the major chip vendors utilized predict L70 life up to 278,000 hours T4A (T4) T4 T4 T3C T4 T3C T4A (T4) T4 T4 T3C T4 T3C T4A (T4) T4 T4 T3C T4 T3C T4A (T4) T4 T4 T3C T4 T3C KFLH VAC T4A (T4) T KFLH VAC T4A (T4) T p Dust Aiming Angles KFLH MOUNTS AND ACCESSORIESj CATALOG NUMBER DESCRIPTION Steel Slipfitter for 2 Pipe (2-3/8 o.d.) Tenon. Slips 3.75 Over Pipe. Heavy Duty Cast-Iron Crossarm Fitting for Horizontal Trunnion Heavy Duty Wall Mount and/or Pipe Clamp Fitting Clamps 2 Pipe (2-3/8 o.d.) Through 2-1/2 Pipe (2-7/8 o.d.) Heavy Duty Steel Wall Bracket. (Must be with Crossarm Fitting) Heavy Duty Steel Wall Bracket 2 Pipe (2-3/8 o.d.) Tenon Fitting. Use with. KFLG VMSC10k KFLH-DARKl KFLH-DOOR Wire Guard, 316 Stainless Steel (order 2 per fixture) 10 Stainless Steel Safety Cable with loop grip Dark Sky Visor, White Painted Aluminum Replacement Internal Reflector and Lens Assembly (order 2 per fixture as required) j Fittings available to adapt trunnion mount floodlights to crossarms, poles and walls. Must be ordered separately. k Drop limit 1. Attaches to luminaire cable provision and to mounting structure. l Designed to eliminate uplight when aimed at 45. Slipfitter Wall Bracket Wall/Pipe Bracket Cross Arm Mount 4041 Tenon Fitting SEE SOFTWARE FOR LATEST LED PHOTOMETRY 7

10 KILLARK Z A H LO C KF1L SERIES C1D1 FLOOD INTRODUCTION & LOGIC Class I, Div. 1&2, Groups B,C,D Class I, Zone 1&2, Groups IIB+H2, IIA Class II, Div. 1&2, Groups EFG, Class III Enclosure Type 4X, IP66 (-50 C to +55 C) File LR11713 LED FEATURES-SPECIFICATIONS Applications LED KF1L Series Explosion-proof Floods are designed for installations where moisture, dirt, dust, corrosion and vibration may be present, or NEMA 3 and 4X areas where wind, water, snow or high ambients can be expected. They can be used in locations made hazardous by the presence of flammable vapors or gases or combustible dusts as defined by the NEC. Typical applications include manufacturing plants, and certain chemical and petrochemical processing facilities, sewage treatment plants, off-shore and dockside installations, garages and storage facilities Compliances UL-8750 for LED lighting ANSI/UL 1598A UL-844 Standard for lighting fixtures for hazardous locations, Class I, Division 1; Class II, Division 1; Class III CSA C22.2 no. 137-M1981 electric luminairies for use in hazardous locations IEX or IEX4B suffix for Zone 1 and Zone 21 to IEC , , , Standards Enclosed and gasketed NEMA 3, 4X IP66 Materials Body, end caps and lens frame corrosion resistant copper-free aluminum alloy with baked powder epoxy/polyester finish, electrostatically applied for complete, uniform corrosion protection All external hardware - stainless steel Thermal shock and impact resistant extra heavy-duty glass lens High temperature silicone gasketing Trunnion heavy gauge 316 SS LED Flood Features and Standards Factory Sealed Construction One 3/4 NPT & one M20 entry standard (see logic for other choices) Supplemental surge protection (AC models VAC only) and looping terminals are standard Crisp White Light for Excellent Color Rendering Chromaticity 5000 K (CCT); approx. 70 CRI Energy Savings High lumens per watt Long Life 100,000+ maintenance free hours to 70% initial lumens Instant On Including after power interruption World Voltage VAC 50/60Hz Solder-LESS LED Board Connections Vibration Resistant LM80-08* Measurement of lumen maintenance for LED light sources LM79-08* Certified Absolute Photometry, including Chromaticity Color for Solid State Lighting L70 Values Industry Nomenclature for Hours of use to 70% of initial Lumens TM- 21* & calculated IEC Ex Rated model (w/iex or IEX4B suffix) Zone 1, Zone 21 Ex de IIB+H2 T6..T5, Gb, IP66 Tamb -20 C Ta +55 C; Option LT for -50 C Ta +55 Cj Ex de IIB T6..T5, Gb, -50 C Ta +55 Cj Ex tb IIIC T90 C Db, -50 C Ta +55 Cj Certificate IECEX CSA ATEX Certificate SIRA14ATEX1159X Patent Pending Fixture Design KF1L with Slipfitter mount on 2 pipe Dark Sky Visor KF1L-DARK Catalog Number Logic KF1L XX KF1L - Series Constant Fixture Wattage W W W W W W W Voltage VAC 50/60Hz VAC 60Hz (90W-125W) VDC (90W-125W) Options IEX4B - Four bolt termination cover (see Note 1) LT - For -50 C to +55 C, IEC Zone 1 (see Note 1) F - Single Fuse FF - Double Fusek D20 - Dual M-20 Entries D25 - Dual M-25 Entries D75 - Dual 3/4 NPT Suitable for Paint Spray * LM-xx & TM-xx are illumination Engineering Society Standards designed to promote uniformity in testing procedures among test labs and manufacturers. For more information go to j Construction/Certification Notes: KF1L units are standard with one 3/4 NPT hub & one M20 hub both plugged, with an 8-bolt factory sealed termination chamber, suitable for CID1 BCD -50 C to +55 C and IEC Zone 1 Ex de suitable for -20 C to 55 C. Use option LT for models needing IEC Zone 1, -50 C to +55 C suitability for hydrogen. Option IEX4B utilizes 4 terminal cover bolts for Ex de and maintains all ratings EXCEPT CID1 BCD. See logic for other entry options k Fusing not for Canadian or Marine Installations 8

11 KILLARK KF1L SERIES H A Z LO C j Yellow highlighted models have extra high lumen LED s. k See logic for V availability l Amperage measured at 120VAC; 277VAC calculated m Use minimum 75 Supply C Ambient; C Ambient n CID1 40 /55 & C2D1 40 C use Aiming Figure A below. C1D1 FLOOD ORDERING & TECHNICAL DATA ORDERING INFORMATION AND AMBIENT SUITABILITY C1D1 C2D1 IEC ZONE 1 IEC ZONE 21 L70 CATALOG NO. WEIGHT LBS./KG WATTS VOLTAGE AMPS LUMENS 40 C 55 C 40 C 55 C 40 C 55 C 40 C 55 C TM-21 CALCULATED KF1L VAC KF1L VAC KF1L VDC KF1L VAC KF1L VAC KF1L VDC KF1L VAC KF1L / VAC KF1L VDC KF1L VAC KF1L VAC KF1L VDC T6 T6 (EFG) o T6 T T6 T6 (EFG) o T6 T T6 T6 (EFG) o T6 T T6 T6 (EFG) o T6 T KF1L VAC T T KF1L VAC T T KF1L VAC T T o 55 C C2D1 EFG T3C Aiming Figure B, 55 C2D1 EF T3A Aiming Figure A p First number is lens temperature under 25mm layer of dust; Second number is lens temp for dust cloud. ** TM-21 based values require very long duration testing. IES TM-21 official reported is based on at 8,000 to 10,000 hours of LED chip manufacturer s LM-80 Testing at printing. Dimensions [397.4] [317.5] 2.52 [64.0] 6.91 [175.5] 4.27 [108.5].531 DIA. (13) 3-1/8 (79) Aiming Figures See Notes n & o 9.36 [237.7] 5.30 [134.7] Trunnion Mounting Detail [450.9] Front Side 2.00 [50.8] KFL MOUNTS AND ACCESSORIESj CATALOG NUMBER DESCRIPTION Steel Slipfitter for 2 Pipe (2-3/8 o.d.) Tenon. Slips 3.75 Over Pipe. Heavy Duty Cast-Iron Crossarm Fitting for Horizontal Trunnion Heavy Duty Wall Mount and/or Pipe Clamp Fitting Clamps 2 Pipe (2-3/8 o.d.) Through 2-1/2 Pipe (2-7/8 o.d.) Heavy Duty Steel Wall Bracket. (Must be with Crossarm Fitting) Heavy Duty Steel Wall Bracket 2 Pipe (2-3/8 o.d.) Tenon Fitting. KFLG VMSC10 KF1L-DARK KF1L-DOOR Wire Guard, 316 Stainless Steel 10 Stainless Steel Safety Cable with loop gripk Dark Sky Visor, White Painted Aluminuml Replacement Door and Lens Assembly j Fittings available to adapt trunnion mount floodlights to crossarms, poles and walls. Must be ordered separately. k Drop limit 1. Attaches to luminaire cable provision and to mounting structure. l Designed to eliminate uplight when aimed at 45. Slipfitter Wall Bracket Wall/Pipe Bracket Cross Arm Mount 4041 Tenon Fitting SEE SOFTWARE FOR LATEST LED PHOTOMETRY 9

12 KILLARK CONTROLS CONTROLS Z A H LO C XS/XST SERIES TUMBLER SWITCH Class I, Div. 1 & 2, Groups C, D Class l, Zones 1 & 2, Groups llb, lla Class II, Div. 1 & 2, Groups E, F, G Class Ill NEMA 7 (C, D) 9 (E, F, G) - FILE E53360 Certified - File LR11712 File OP7A5.AE See files for details or call Killark. Applications Used where making, breaking, or changing connections in an electric circuit are required. Features XS-3C FEATURES-SPECIFICATIONS XS and XST Series are front lever rotary operated switch assemblies with standard provisions for padlocking in either ON or OFF position. The lever is connected to a threaded stainless steel shaft which passes through the cover. WITH DEVICE XS-1C XS-2C XS-8C XS-3C XS-5C XS-6C XS-7C XS-1D XS-2D Complete Unit When Assembled COVER WITHOUT DEVICE XNS-1C XNS-2C XNS-8C XNS-3C XNS-5C XNS-6C XNS-7C XNS-1D XNS-2D XS TUMBLER SWITCH CATALOG NUMBER COMPLETE UNITS (BOX, COVER AND SWITCH) HUB SIZE DEAD-END FEED-THRU 1/2 XS-11C XS-41C 3/4 XS-21C XS-51C 1/2 XS-12C XS-42C 3/4 XS-22C XS-52C 1/2 XS-18C XS-48C 3/4 XS-28C XS-58C SWITCH STYLE 1-POLE 2-POLE 3-POLE 1/2 XS-13C XS-43C 3-WAY/ SPDT 3/4 XS-23C XS-53C No center off 1/2 XS-15C XS-45C SPDT 3/4 XS-25C XS-55C Center off 1/2 XS-16C XS-46C DPDT 3/4 XS-26C XS-56C No center off 1/2 XS-17C XS-47C DPDT 3/4 XS-27C XS-57C Center off 1/2 XS-11D XS-41D 3/4 XS-21D XS-51D 1/2 XS-12D XS-42D 3/4 XS-22D XS-52D 1-POLE 2-POLE SWITCH RATING 120/277 VAC, 1Ø 20Ak 20Ak j 20Ak 20Ak 20Ak 20Ak 30Ak 30Ak XS-4C 4-WAY 20Ak j Rated 15 amperes, 240/480 VAC., 3Ø: 3HP-240 VAC., 5 HP-480 VAC. k Horsepower rated 1 HP at 120VAC, 2 HP at 240VAC. Certified - File LR11712 HUB SIZE XS TUMBLER SWITCH CATALOG NUMBER COMPLETE UNITS SWITCH STYLE (BOX, COVER AND SWITCH) DEAD-END FEED-THRU 3/4 XST15-21C XST15-51C 1 XST15-31C XST15-61C 3/4 XST20-21C XST20-51C 1 XST20-31C XST20-61C 1-Pole 1-pole 3/4 XST15-23C XST15-53C 3-way/spdt No center 1 XST15-33C XST15-63C off 3/4 XST20-23C XST20-53C 3-way/spdt No cover 1 XST20-33C XST20-63C off SWITCH RATING 347 VAC, 1Ø 15a 20a 15a 20a 10

13 KILLARK CONTROLS CONTROLS HKH SERIES H A Z LO C SIZE 1 NON-METALLIC 2 POLE ROCKER SWITCH FEATURES-SPECIFICATIONS ATEX/IECEx Certified 0539 II 2 G Ex de IIC T4 Gb 0539 II 2 D Ex tb IIIC T4 Db IP66 DEMKO 15 ATEX 1405X Ex de IIC Gb Ex tb IIIC Db IP66 IECEx UL X Ambient Range: -45ºC < Ta < 60ºC culus Certified Class I, Zone 1, AEx de IIC Gb / Ex de IIC Gb X Zone 21, AEx tb IIIC Db IP66 / Ex tb IIIC Db IP66 X Class I, Division 2, Groups A, B, C, D Class II, Division 1, Groups E, F, G (Canada Only) Class II, Division 2, Groups E, F, G Class III UL50, 50E, 508, UL , -1, -7, -31 Type 3, 4, 4X, 12, 13 Ambient Range: -45ºC < Ta < 60ºC Rocker Switch Single Throw Double Pole Luminous fluorescent strip supplied for ease of locating. One entry listed is located at bottom. Contact Block Features: UL Electrical Rating: 690Vac, 20A, 50-60Hz, 60Vdc, 5A, 110Vdc, 2A, 255Vdc, 1.5A, 1/2 1 HP@208/240/277Vac, A600/P600- Pilot Duty 350Vac- Tungsten Lamp. Wire Allowances: WIRE RANGE with 1 or 2 WIRES: #22 to #12 AWG (SOL & STR) and #10 AWG (STR). IEC Electrical Ratings: AC690V 16A AC-12, Hz, AC230V 16A AC-15, 50-60Hz, DC60V 5A DC-12, DC125 1A DC-12. Wire Allowances: WIRE RANGE with 1 or 2 WIRES: 0.5 to 2.5mm (SOL & STR) and 4.0mm 2 (STR) Silver Alloy contacts with Gold Flashing. Enclosure depth 4.5 (114mm) HKH ROCKER SWITCH MAINTAINED IN 2 POSITIONS CATALOG NUMBER CONTACT ARRANGEMENT ENTRY SIZE DIN RAIL MOUNT IEC NEMA HKH1AND2RS4K8 3/4 NPT SS HUB HKH1ANDARS4 M20 Clearance hole CONTACT BLOCKS 2 N.O. HKH ROCKER SWITCH MAINTAINED IN 2 POSITIONS CATALOG NUMBER CONTACT ARRANGEMENT ENTRY SIZE DIN RAIL MOUNT IEC NEMA CONTACT BLOCKS HKH1AND2RS1K8 HKH1ANDARS1 3/4 NPT SS HUB M20 Clearance hole N.C. / 1 N.O. 11

14 3940 Dr. Martin Luther King Drive St. Louis, MO TEL: (314) FAX: (314) Hubbell Canada LP 870 Brock Road South Pickering, Ontario L1W 1Z8 (905) Hubbell de Mexico Av. Insurgentes Sur 1228, Piso 8 Col. Tlacoquemécatl Del Valle C.P , Mexiso D.F. Tel: (01 52) info@hubbell.com.mx Hubbell Electrical Systems A Division of Hubbell, Inc. (Delaware) HKMC-FLOOD 2015 Hubbell Electrical Systems Printed in U.S.A.

LED FLOOD LIGHT SOLUTIONS Harsh and Hazardous Products

LED FLOOD LIGHT SOLUTIONS Harsh and Hazardous Products LED FLOOD LIGHT SOLUTIONS Harsh and Hazardous Products www.hubbell-killark.com L TI IGH NG HA Z LO C LED FLOOD LIGHTS FLOOD H A Z LO C INDEX PRODUCT PAGE NO. NEMA 4 (or 4X or IP66) Class I, Div. 2 / Zone

More information

LOW PROFILE LINEAR ALUMINUM LED EXCLUSIVE DESIGN FEATURES

LOW PROFILE LINEAR ALUMINUM LED EXCLUSIVE DESIGN FEATURES KILLARK Z A H LO C LOW PROFILE LINEAR ALUMINUM LED EXCLUSIVE DESIGN FEATURES High temperature rated silicone gasketing provides NEMA 4X & IP66 sealing. Diffused 2 Lens Choices: Clear for maximum lumens

More information

LOW PROFILE LINEAR ALUMINUM LED EXCLUSIVE DESIGN FEATURES

LOW PROFILE LINEAR ALUMINUM LED EXCLUSIVE DESIGN FEATURES L KILLARK TI IGH NG HA Z LO C LOW PROFILE LINEAR ALUMINUM LED EXCLUSIVE DESIGN FEATURES High temperature rated silicone gasketing provides Type 4X & IP66 sealing. Diffused Clear 2 Lens Choices: Clear for

More information

HKH Series. HAZCON Controls for Harsh and Hazardous Environments

HKH Series. HAZCON Controls for Harsh and Hazardous Environments HKH Series HAZCON Controls for Harsh and Hazardous Environments Z A H LO C NON-METALLIC DIN RAIL MOUNT Component Mounting Rail Optional Customer I.D. Nameplate Optional Legend Plate Explosion Protective

More information

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures Mercmaster Series Luminaires LIGHTING: ENCLOSED AND GASKETED AREA /INDUCTION Applications Enclosed and gasketed fixtures suitable for use in: Marine and wet locations A wide range of industrial, chemical

More information

Areamaster 1000 Floodlights Integrally Ballasted W HID For hazardous locations.

Areamaster 1000 Floodlights Integrally Ballasted W HID For hazardous locations. A, IIB, IIC Applications Powerful, efficient weatherproof lighting for large areas such as: Pulp and paper mills Processing plants Chemical plants Oil refineries Foundries Storage areas Waste and sewage

More information

EXBLI & EXBSPI Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments

EXBLI & EXBSPI Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments EXBLI & EXBSPI Series Circuit Breaker Panelboards for Harsh and Hazardous Environments KILLARK Z A H LO C NEMA 4X O Ring Gasket Stainless Steel Tri-Lead Cover New Slide MCB Assembly Handles Padlockable

More information

Areamaster LED Flood/High Bay Luminaires For Hazardous Locations. 250 W, 400 W, 750 W, 1000 W HID Light Level Equivalent

Areamaster LED Flood/High Bay Luminaires For Hazardous Locations. 250 W, 400 W, 750 W, 1000 W HID Light Level Equivalent Class I, Division 2, Groups A, B, C, D Class I, Zone 2 Group IIC Class II, Division 1, Groups E, F, G Class II Division 2, Groups F, G Class III Simultaneous Exposure Type 3R, 4, 4X IP66/67 Applications

More information

Power (W) Tamb 40 o C LX1GAM4LB57 5,700 10, T3 T100 o C T4 T85 o C 13

Power (W) Tamb 40 o C LX1GAM4LB57 5,700 10, T3 T100 o C T4 T85 o C 13 Gamma Floodlight IP66/67 The Gamma is a high output LED floodlight is designed for use in Zone 1 & 21 hazardous areas. The compact design and flexible mounting allows the Gamma to also be used as a lowbay.

More information

L1L Series. LED Luminaire for Harsh and Hazardous Environments

L1L Series. LED Luminaire for Harsh and Hazardous Environments L1L Series LED Luminaire for Harsh and Hazardous Environments L TI IGH NG HA Z LO C T-slot for easy mounting using a 5/16 or M8 bolt ¾ NPT on 3 sides with Available M20 hub option Removable Ceiling Flush

More information

COMPACT FLUORESCENT EMERGENCY FIXTURES

COMPACT FLUORESCENT EMERGENCY FIXTURES KILLARK H A Z LO C COMPACT FLUORESCENT EMERGENCY FIXTURES VE3Q/VE4Q Class I, Div. 2, Groups A,B,C,D Class l, Zone 2, Groups IIC, llb, lla Class II, Div. 1 & 2, Groups E,F,G Class III NEMA 3, 4, 4X IP66

More information

TERMINAL BOXES FOR HARSH & HAZARDOUS ENVIRONMENTS

TERMINAL BOXES FOR HARSH & HAZARDOUS ENVIRONMENTS OSUR CL HA ES EN KILLARK Z LO C SJIC SERIES TERMINAL BOXES FOR HARSH & HAZARDOUS ENVIRONMENTS Screw cover style, with or without continuous hinge 3/16 (5mm) wide flat flange for maximum gasket surface

More information

ACTUATOR ASSEMBLIES FOR PANEL MOUNT APPLICATIONS

ACTUATOR ASSEMBLIES FOR PANEL MOUNT APPLICATIONS Z A H LO C ACTUATOR ASSEMBLIES FOR PANEL MOUNT APPLICATIONS BASIC CATALOG NUMBERS HKHPBMMSS1 HKHPBMMTC1 HKHPBILLMM1 HKHPBMMMR1 HKHPBMMMB1 HKHPBMMMG1 HKHDBLPBMMGR1 HKHPBPMTMR1 HKHPBPMTMB1 HKHPBPMTMG1 HKHPBTMTMR1

More information

STAINLESS STEEL PANEL MOUNT

STAINLESS STEEL PANEL MOUNT Z A H LO C STAINLESS STEEL PANEL MOUNT Optional Legend Plate Cover Screw Retaining Washer Panel Mount Bracket Explosion Protective LED Pilot Light Stainless Steel Washer Actuator Spacer Locknut Explosion

More information

Areamaster LED Flood/High Bay Luminaires

Areamaster LED Flood/High Bay Luminaires Applications Typical applications include: Pulp and paper mills Processing plants Chemical plants Oil refineries Foundries Storage areas Waste and sewage treatment Parking garages Other areas where dust,

More information

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures ATEX/IECEx: Zone 2 and 22 II 2 GD Lighting LIGHTING: ENCLOSED AND GASKETED AREA LED/INDUCTION Applications Enclosed and gasketed fixtures suitable for use in: Marine and wet locations A wide range of industrial,

More information

N2LED Series Emergency Luminaires Non-Metallic Emergency Egress Lighting Systems with Remote or Direct Mounted Lamps.

N2LED Series Emergency Luminaires Non-Metallic Emergency Egress Lighting Systems with Remote or Direct Mounted Lamps. Applications Enclosed and gasketed, non-metallic emergency lighting system suitable for use in areas where flammable gases or vapors may become present due to abnormal, unusual or accidental conditions

More information

INCANDESCENT/COMPACT FLUORESCENT/MEDIUM BASE HID

INCANDESCENT/COMPACT FLUORESCENT/MEDIUM BASE HID KILLARK INCANDESCENT/COMPACT FLUORESCENT/MEDIUM BASE HID Class I, Div. 1 & 2, Groups C,D Class I, Zones 1 & 2, Groups llb, lla Class II, Div. 1 & 2, Groups E,F,G Class III, Div. 1 & 2 Suitable for wet

More information

SAFR LED SERIES S A F R L E D. Hazardous Location LED Luminaire

SAFR LED SERIES S A F R L E D. Hazardous Location LED Luminaire SAFR LED SERIES Hazardous Location LED Luminaire Class I, Division 2, Groups A, B, C & D Class II, Division & 2, Groups E, F & G Class III Class I, Zone 2, Groups IIA, IIB & IIC UL 8750 LED Safety UL 844

More information

LAL Series LINEAR LED TECHNOLOGY. for Harsh and Hazardous Environments

LAL Series LINEAR LED TECHNOLOGY. for Harsh and Hazardous Environments LAL Series LINEAR LED TECHNOLOGY for Harsh and Hazardous Environments KILLARK Z A H LO C LOW PROFILE LINEAR ALUMINUM LED EXCLUSIVE DESIGN FEATURES High temerature rated silicone gasketing rovides NEMA

More information

HKH Series. HAZCON Controls for Harsh and Hazardous Environments

HKH Series. HAZCON Controls for Harsh and Hazardous Environments (93) A ø 0.2" (ø 5.5) 1.9 (4 3.7" (93) B A " 0) 8" 0) HKH Series HAZCON Controls for Harsh and Hazardous Environments 0.2" (5.5) 0.2" (5.5) 3.1" (80) 2.8" (70) ø 0.2" (ø 5.5) 1.9" (48) 3.7" (93) A B 0.2"

More information

Hazardous Area LED Lighting Champ FMV LED Luminaires. Champ FMV. LED floodlights for harsh and hazardous areas

Hazardous Area LED Lighting Champ FMV LED Luminaires. Champ FMV. LED floodlights for harsh and hazardous areas Hazardous Area LED Lighting Champ FMV LED Luminaires Champ FMV LED floodlights for harsh and hazardous areas Champ FMV LED floodlights Safe. Reliable. Efficient. Featuring the industry's broadest range

More information

D2LC Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments

D2LC Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments D2LC Series Circuit Breaker Panelboards for Harsh and Hazardous Environments IBUTI TR HA ON DIS KILLARK Z LO C Type 4X Gasket Stainless Steel Tri-Lead Cover Bolts Spare Sealed Wires Termination at Terminal

More information

SAFR LED S A F R L E D. LED Area Lighting for Hazardous Locations

SAFR LED S A F R L E D. LED Area Lighting for Hazardous Locations LED Class I, Division 2, Groups A, B, C & D Class II, Division & 2, Groups E, F & G Class III Class I, Zone 2, Groups IIA, IIB & IIC UL 8750 LED Safety UL 844 Hazardous Locations UL 598 Wet Locations UL

More information

Pauluhn ZPL explosionproof LED luminaires For drilling and marine applications

Pauluhn ZPL explosionproof LED luminaires For drilling and marine applications Pauluhn ZPL explosionproof linear LEDs are designed to replace fluorescent T12, T8 and T5HO lighting on marine vessels and land-based and offshore drilling platforms. The rugged and durable design features

More information

4L EVM Hazard Gard H.I.D. Luminaires Mogul Base Factory Sealed (Groups C.D)

4L EVM Hazard Gard H.I.D. Luminaires Mogul Base Factory Sealed (Groups C.D) 4L EVM Hazard Gard H.I.D. Luminaires Mogul Base Factory Sealed (Groups C.D) Cl. I, Div. 1 Groups B (GB suffix),c,d (with suffix GB), IIB IIA Paint Spray (100W max) Application: Hazard Gard luminaires are

More information

MOGUL BASE HID FIXTURES

MOGUL BASE HID FIXTURES KILLARK Z A H LO C MOGUL BASE HID FIXTURES Class I, Div. 1 & 2 Groups C,D Class l, Zone 1 & 2, Groups llb,lla Class l, Zone 1, AEx d IIB Class II, Div. 1 & 2, Groups Class III, Div. 1 & 2 Suitable for

More information

Rig-A-Lite LED Luminaire Guide. Superior LED Technology for Hazardous and Severe Environments. Five-Year Warranty

Rig-A-Lite LED Luminaire Guide. Superior LED Technology for Hazardous and Severe Environments. Five-Year Warranty Rig-A-Lite LED Luminaire Guide Superior LED Technology for Hazardous and Severe Environments Five-Year Warranty Rig-A-Lite LED Luminaires The Rig-A-Lite LED luminaires are the perfect combination of dependability,

More information

25W Explosion Proof LED Light - C1D1-2 - C2D1-2 - Surface Mount - 50' Cord w/ EXP Plug

25W Explosion Proof LED Light - C1D1-2 - C2D1-2 - Surface Mount - 50' Cord w/ EXP Plug 25W Explosion Proof LED Light - C1D1-2 - C2D1-2 - Surface Mount - 50' Cord w/ EXP Plug Part #: EXHL-SFC-LE1-50C-1227-EPP Page: 1 Made in Texas The EXHL-SFC-LE1-50C-1227-EPP from Larson Electronics is an

More information

AUTHENTIC LIFE SAFETY PRODUCTS SINCE 1940

AUTHENTIC LIFE SAFETY PRODUCTS SINCE 1940 AUTHENTIC LIFE SAFETY PRODUCTS SINCE 1940 NEMA 4X C1D2/C2D1 INDUSTRIAL HIGH LUMEN LED EMERGENCY LIGHT DUAL-LITE.COM INNOVATIVE LED NEMA 4X C1D2/C2D1 Industrial Emergency Light The Dynamo Series offers

More information

SAF SERIES Hazardous Location Mogul Base HID and Compact Flourescent

SAF SERIES Hazardous Location Mogul Base HID and Compact Flourescent SAF SERIES Hazardous Location Mogul Base HID and Compact Flourescent S A F Class I, Division 2, Groups A, B, C & D Class II, Division 1 & 2, Groups E, F & G Class III Zone 2, Groups IIA, IIB & IIC UL 844

More information

Floodlight LED Series 6525

Floodlight LED Series 6525 www.stahl.de > Floodlight Zones 2, 21 and 22 with highly efficient LEDs > 3 different light distribution types for adjusting to the illumination task > Standard enclosure made of sheet steel single powder

More information

156W Explosion Proof Portable LED 360 Degree Flood Low Profile Light System - 2ft - Tank Cleaning

156W Explosion Proof Portable LED 360 Degree Flood Low Profile Light System - 2ft - Tank Cleaning 156W Explosion Proof Portable LED 360 Degree Flood Low Profile Light System - 2ft - Tank Cleaning Part #: EPL-360-3XLP24-LED-V2-100 Page: 1 Made in Texas The EPL-360-3XLP24-LED-V2-100 Portable Explosion

More information

80 Watt Multi-Purpose LED Area Light

80 Watt Multi-Purpose LED Area Light JGMPAL Watt Multi-Purpose LED Area Light STANDARD Project: Type: Catalog #: WET kv Surge Protection IP65 The JGMPAL series is a group of architectural LED area luminaires designed to illuminate parking

More information

AFL FLOODLIGHT SERIES

AFL FLOODLIGHT SERIES AFL FLOODLIGHT SERIES A FL Flood Lighting for Hazardous Locations Class I, Division 2, Groups A, B, C & D UL 844 Hazardous Locations UL 598A Marine Outside Type Zone 2, Groups IIA, IIB & IIC CUL Cast Aluminum

More information

ATX FN Series Heavy Duty Nonmetallic Fluorescent Luminaires Standard and Emergency Back-Up. Zone 2-21 and 22

ATX FN Series Heavy Duty Nonmetallic Fluorescent Luminaires Standard and Emergency Back-Up. Zone 2-21 and 22 Applications Can be installed in hazardous areas designated as Zone 2, 21 and 22. For use in locations where a high degree of corrosion resistance is required. For indoor/outdoor use where protection against

More information

Areamaster 100 Wide-Beam Floodlights 70 W, 100 W, 150 W HPS; 70 W, 100 W, 150 PSMH For general, marine and hazardous locations.

Areamaster 100 Wide-Beam Floodlights 70 W, 100 W, 150 W HPS; 70 W, 100 W, 150 PSMH For general, marine and hazardous locations. Areamaster 100 Wide-Beam Floodlights NEC CEC V Class II, Divisions I and 2, Groups E, F, G V Class III Applications Highly efficient, all-weather flood-lighting for lower wattage service. Well suited for:

More information

SAF SERIES Hazardous Location Mogul Base HID and Compact Flourescent

SAF SERIES Hazardous Location Mogul Base HID and Compact Flourescent SAF SERIES Hazardous Location Mogul Base HID and Compact Flourescent S A F Class I, Division 2, Groups A, B, C & D Class II, Division 1 & 2, Groups E, F & G Class III Zone 2, Groups IIA, IIB & IIC UL 844

More information

LEDMPAL15 15 Watt Multi-Purpose LED Area Light

LEDMPAL15 15 Watt Multi-Purpose LED Area Light LEDMPAL15 15 Watt Multi-Purpose LED Area Light Project: Type: Catalog #: STANDARD FEATURES WET 1kV Surge Protection Available in 3000k (warm white), 4000K (neutral white) and 5000K (cool white). * Long-life

More information

FV Series Nonmetallic Fluorescent Luminaires For Hazardous and Adverse Locations

FV Series Nonmetallic Fluorescent Luminaires For Hazardous and Adverse Locations Applications For use in hazardous locations defined by the NEC and CEC as Class I, Division 2, Groups A, B, C and D; Class II, Division 2, Groups F and G; Marine Outdoor Salt Water; UL1598A and. As well

More information

Fluorescent Lighting FE Series: Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Increased Safety

Fluorescent Lighting FE Series: Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Increased Safety Fluorescent Lighting FE Series: Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Increased Safety Zone & & II GD IP66/67 IK0 Applications: Can be installed in hazardous

More information

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY EDSC210 -Way Switch Cooper Crouse-Hinds Catalog Number Manufacturer Description Weight per unit Product Category Features Box Type Contact Configuration Current Rating Voltage Rating Material, Color, and

More information

Floodlight LED Series 6525

Floodlight LED Series 6525 www.stahl.de > Floodlight Zones 2, 21 and 22 with highly efficient LEDs > 3 different light distribution types for adjusting to the illumination task > Standard enclosure made of single-coated stainless

More information

Code Master Incandescent Factory Sealed Luminaires Explosionproof, Dust-Ignitionproof For use with threaded metal conduit.

Code Master Incandescent Factory Sealed Luminaires Explosionproof, Dust-Ignitionproof For use with threaded metal conduit. Applications For use in hazardous locations such as plants where plastics, paints, thinners and petrochemicals are manufactured. For use in chemical and petrochemical plants, such as manufacturers of plastics,

More information

Industrial Areamaster LED Flood/High Bay Luminaires For Ordinary Locations. 250 W, 400 W, 750 W HID Light Level Equivalent

Industrial Areamaster LED Flood/High Bay Luminaires For Ordinary Locations. 250 W, 400 W, 750 W HID Light Level Equivalent NEC/CEC: Type 3R, 4X IP66, IP67 Suitable for use in Wet Locations Marine Outside Type (Salt Water) Applications Powerful, efficient weatherproof lighting for applications such as: Security lighting Production

More information

Floodlight LED Series 6125

Floodlight LED Series 6125 www.stahl.de > Floodlight Zones 1, 2 and 21, 22 with highly efficient LEDs > 3 different light distribution types for adjusting to the illumination task > Enclosure made of sheet steel single powder coated

More information

SAF SERIES Hazardous Location Mogul Base HID and Compact Flourescent

SAF SERIES Hazardous Location Mogul Base HID and Compact Flourescent SAF SERIES Hazardous Location Mogul Base HID and Compact Flourescent S A F Class I, Division 2, Groups A, B, C & D Class II, Division 1 & 2, Groups E, F & G Class III Zone 2, Groups IIA, IIB & IIC UL 844

More information

Atex Range Designed for used for oil gas, petrochemical, aviation, marine, mining and utility applications.

Atex Range Designed for used for oil gas, petrochemical, aviation, marine, mining and utility applications. Atex Range Designed for used for oil gas, petrochemical, aviation, marine, mining and utility applications. Intrinsically Safe Explained Ha ardous Area Classification Zone 0, Zone, Zone This diagram shows

More information

24W Explosion Proof POE Injector - Adds Power Over Ethernet Functionality to 24V POE Equipment - 1A

24W Explosion Proof POE Injector - Adds Power Over Ethernet Functionality to 24V POE Equipment - 1A 24W Explosion Proof POE Injector - Adds Power Over Ethernet Functionality to 24V POE Equipment - 1A Part #: EXP-IP-POE-INJ-24V-24W Page: 1 The EXP-IP-POE-INJ-24V-24W from Larson Electronics is an Explosion

More information

Lighting: Fluorescent Lighting FL Series: Light Duty Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Zone 2 & 22

Lighting: Fluorescent Lighting FL Series: Light Duty Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Zone 2 & 22 FL Series: Light Duty Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up 2 x 58 W 2 x18 W Compliance Data: ATEX IEC: Zone 2 22 ATEX IEC CE Ex nr II or na II T6 or T5 or T4

More information

LED lighting for drilling & marine Pauluhn ZPL LED luminaires. Pauluhn ZPL. LED luminaires for drilling & marine applications

LED lighting for drilling & marine Pauluhn ZPL LED luminaires. Pauluhn ZPL. LED luminaires for drilling & marine applications LED lighting for drilling & marine Pauluhn ZPL LED luminaires Pauluhn ZPL LED luminaires for drilling & marine applications Pauluhn ZPL explosionproof LEDs Safe. Reliable. Efficient. Featuring the industry's

More information

Lighting: Fluorescent Lighting RE Series: Recessed Fluorescent Lighting Fixtures, Standard and Emergency Back-Up Increased Safety

Lighting: Fluorescent Lighting RE Series: Recessed Fluorescent Lighting Fixtures, Standard and Emergency Back-Up Increased Safety 4 x 18 W Surface Mounting 2 x 36 W Recessed Compliance Data: ATEX IECEx: ATEX IECEx CE Ex de IIC or Ex demb IIC (emergency version) T6 to T4 Ex td A21 T 75 C Technical Data: 18 W 36 W 58 W 1, 2, 3 & 4

More information

GHG43 Series Control Stations

GHG43 Series Control Stations GHG43 Series Control Stations Nonmetallic or 316L Stainless Steel UL/cUL listed Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zones 1 and 2, (A) Ex de IIB + H2 T6 Cl. II, Div. 1, Groups E, F, G (cul) PTB ATEX

More information

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL Series Features: Color coding and pin configuration makes it physically impossible to mate plugs and receptacles of different voltages and current ratings (per IEC 60 309-2). Interlocked switch mechanism

More information

Heavy industrial LED lighting Champ Pro PFM LED luminaires. Champ PFM. LED floodlights for heavy industrial areas. Authorized Distributor

Heavy industrial LED lighting Champ Pro PFM LED luminaires. Champ PFM. LED floodlights for heavy industrial areas. Authorized Distributor Heavy industrial LED lighting Champ Pro PFM LED luminaires Champ PFM LED floodlights for heavy industrial areas Authorized Distributor Champ Pro PFM LED floodlights Safe. Reliable. Efficient. Featuring

More information

MHDS SERIES M H D S. Stainless Steel Marine Heavy Duty Luminaire for Hazardous Locations

MHDS SERIES M H D S. Stainless Steel Marine Heavy Duty Luminaire for Hazardous Locations MHDS SERIES Stainless Steel Marine Heavy Duty Luminaire for Hazardous Locations Class I, Division 2, Groups A, B, C & D Class II, Division 2, Groups F & G Class III UL 844 Hazardous Locations UL 198A Marine

More information

ATX FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety

ATX FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety Applications Can be installed in hazardous areas designated as Zone 1 and 2 21 and 22. For use in locations where a high degree of corrosion resistance is required. For indoor/outdoor use where protection

More information

EDS / EFS Series Control Stations

EDS / EFS Series Control Stations EDS / EFS Series Fully Assembled EFS and EDS Factory Sealed Devices Cl. I, Div. & 2, Groups B*, C, D Cl. II, Div., Groups E, F, G NEMA, 7B*CD, 9EFG Applications: Factory sealed enclosures are installed

More information

SAFJ LED SERIES S A L E D. Hazardous Location Compact LED

SAFJ LED SERIES S A L E D. Hazardous Location Compact LED SAFJ LED SERIES Hazardous Location Compact LED Class I, Division 2, Groups A, B, C, & D Class II, Division 1 & 2, Groups E & F Class III Simultaneous Presence Enclosed & Gasketed Wet Locations NEMA 3R,

More information

Applications. Standard Materials. Certifications and Compliances

Applications. Standard Materials. Certifications and Compliances Code Master 2 HID Factory Sealed Luminaires Class I, Division 1 and 2, Groups C, D Class I, Division 1 and 2, Groups B, C, D Applications Ideal for use in chemical and petrochemical plants, such as manufacturers

More information

1000 Watt Metal Halide Light - Class 1 Division 2 Groups A-D - T3b Temperature - 110,000 lumens

1000 Watt Metal Halide Light - Class 1 Division 2 Groups A-D - T3b Temperature - 110,000 lumens 1000 Watt Metal Halide Light - Class 1 Division 2 Groups A-D - T3b Temperature - 110,000 lumens Part #: HALPRM-1000WMH Made in the USA The extremely durable Larson Electronics HALPRM-1000WMH metal halide

More information

220/230/240V Watt High Pressure Sodium - Hazardous Location Lighting - C1D2 - Pole Mount

220/230/240V Watt High Pressure Sodium - Hazardous Location Lighting - C1D2 - Pole Mount 220/230/240V Watt High Pressure Sodium - Hazardous Location Lighting - C1D2 - Pole Mount Part #: HAL-PRM-250W-HPS-220V-PT Page: 1 Made in the USA The efficient HAL-PRM-250W-HPS-220V-PT high pressure sodium

More information

N2MV Series W Non-metallic

N2MV Series W Non-metallic N2MV Series 50-175W Non-metallic Cl. I, Div. 2, Groups A, B, C, D Cl. II, Groups F, G Cl. III & Simultaneous Presence (100W max) Marine & Wet Locations, R, 4, 4X; IP56 L Applications: N2MV series Champ

More information

MHD2/MHDO SERIES MHD2. Marine Heavy Duty Outdoor Non-Metallic Fluorescent CLASS 1 DIVISION 2 FLUORESCENT LIGHT

MHD2/MHDO SERIES MHD2. Marine Heavy Duty Outdoor Non-Metallic Fluorescent CLASS 1 DIVISION 2 FLUORESCENT LIGHT MHD2/MHDO SERIES Marine Heavy Duty Outdoor Non-Metallic Fluorescent Non-metallic, glass reinforced polyester housing. 3/4 in. NPT aluminum hub. Captive stainless steel latches. Stainless steel mounting

More information

Applications. Standard Materials

Applications. Standard Materials Code Master Jr. HID Factory Sealed Luminaires Integrally Ballasted. 50 W, 70 W, 00 W, 50 W HPS; 50 W, 70 W, 00 W, 75 W PSMH. 75 W MH V. Medium Base. For Use with Threaded Metal Conduit. Class I, Division

More information

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY EDS2274 Pos D.E. Selector Switch Cooper Crouse-Hinds Catalog Number Manufacturer Description Weight per unit Product Category Features Box Type SINGLE GANG Contact Configuration 4NO-4NC Number of Circuits

More information

SafeSite LED Based Signaling for Hazardous Locations

SafeSite LED Based Signaling for Hazardous Locations SafeSite LED Based Signaling for Hazardous Locations On when it matters most. Products and solutions that protect your business 2 www.dialight.com MDTFSFSTBROCHURE_H Features & Benefits 5 year warranty

More information

MHD2/MHDO SERIES M H D 2. Marine Heavy Duty Non-Metallic Fluorescent

MHD2/MHDO SERIES M H D 2. Marine Heavy Duty Non-Metallic Fluorescent MHD2/MHDO SERIES Marine Heavy Duty Non-Metallic Fluorescent Class I, Division 2, Groups A, B, C & D Class II, Division 2, Groups F & G Class III Zone 2, Groups IIA, IIB & IIC UL 844 Hazardous Locations

More information

Applications. Illustrated Features

Applications. Illustrated Features Applications For use in locations where a high degree of corrosion resistance is required. FR Series: For use in areas where high humidity or water vapor are present Typical uses include meat- or food-processing

More information

Applications. Straight Stanchion-Mount Fixture with Prismatic Glass Refractor and Guard. Pendant Mount Fixture with Prismatic Glass Refractor

Applications. Straight Stanchion-Mount Fixture with Prismatic Glass Refractor and Guard. Pendant Mount Fixture with Prismatic Glass Refractor Mercmaster III HID 50-250 Watt Luminaires Applications Enclosed and gasketed fixtures suitable for use in: Marine and wet locations A wide range of industrial, chemical processing and other areas where

More information

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22) Ex-Floodlight PXLED (Ex-Zone 1, 2, 21 and 22) Lighting under harsh conditions The new modular LED floodlight series PXLED is suited for nearly every kind of lighting task in hazardous areas, including

More information

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22) . Ex-Linear LED light fittings ellk/m 9 LED 400/800 / ellk/m 9 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1,, 1, ) The efficient solution for your explosion-protected lighting concept The explosion-protected

More information

Lighting: Incandescent & HID Lighting PB, PC & PL Series: Floodlights Flameproof

Lighting: Incandescent & HID Lighting PB, PC & PL Series: Floodlights Flameproof Ex de IIB Type PB Ex de IIC Type PC Ex de IIB Type PL Low Temperature Rating Compliances: ATEX - IEC: Zone 1 & 2 21 & 22 ATEX IECEx CE Ex de IIB (PB and PL) T4 to T1 Ex td A21 T130 C to T378 C IP66 (Type

More information

HID/FLOODLIGHT: NEC/CEC EXPLOSIONPROOF. Applications. Options

HID/FLOODLIGHT: NEC/CEC EXPLOSIONPROOF. Applications. Options Applications UL Listed for Outside Type (Salt Water). Ideal in Class I, Division 1 and 2 installations in refineries, in pipeline transportation facilities, at drilling rigs and in production facilities

More information

150 Watt Explosion Proof LED Flood Light - Surface Mount - 17,500 Lumens - C1D2-25ft Cord

150 Watt Explosion Proof LED Flood Light - Surface Mount - 17,500 Lumens - C1D2-25ft Cord 150 Watt Explosion Proof LED Flood Light - Surface Mount - 17,500 Lumens - C1D2-25ft Cord Part #: EPLC2-LED-150W-RT-JB2-25C The Larson Electronics EPLC2-LED-150W-RT-JB2-25C Explosion Proof LED Flood Light

More information

ATX PC Series Floodlights Flameproof. Metal Halide, High Pressure Sodium, Mercury Vapor, Halogen

ATX PC Series Floodlights Flameproof. Metal Halide, High Pressure Sodium, Mercury Vapor, Halogen Applications Designed for large area lighting in industrial outdoor and indoor hazardous areas. Ideal for use in Zones 1 and 2 and 21 and 22 in the oil and gas industry. In locations such as: refineries,

More information

FLUORESCENT BI-PIN/MEDIUM BASE HID

FLUORESCENT BI-PIN/MEDIUM BASE HID KILLARK Z A H LO C FLUORESCENT BI-PIN/MEDIUM BASE HID Cass I, Div. 2, Groups A,B,C,D* Cass, Zone 2, Groups C,B,A Cass II, Div. 1 & 2, Groups E,F,G* Cass III Suitabe for wet ocations Marine Rated (US Ony)

More information

WFH LED SERIES L E D. High-Bay Lighting for Hazardous & Wet Locations

WFH LED SERIES L E D. High-Bay Lighting for Hazardous & Wet Locations WFH LED SERIES W FH High-Bay Lighting for Hazardous & Wet Locations Class I, Division 2, Groups A, B, C, & D Class II, Division 2, Groups F & G Class III UL 844 Hazardous Locations UL 1598 Wet Locations

More information

MAR SERIES Fluorescent Lighting for Hazardous Locations

MAR SERIES Fluorescent Lighting for Hazardous Locations MAR SERIES M AR Fluorescent Lighting for Hazardous Locations Class I, Division 2, Groups A, B, C, & D Seismic Tested UL 844 Hazardous Locations UL 924 Emergency Lighting UL 1598A Marine Outside Type CSA

More information

LIGHTING: EXPLOSIONPROOF FLOODLIGHT. Applications. Options

LIGHTING: EXPLOSIONPROOF FLOODLIGHT. Applications. Options Code Master 2 HID Factory Sealed Floodlights NEC: Class 1, Division 1 and 2, Groups C, D Marine Type Electric Fixtures Outside Type (Salt Water) CEC: V Class I, Division 1 and 2, Groups B, C, D Class II,

More information

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NE-HT / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NE-HT / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22) . Ex-Linear LED light fittings ellk/m 9 LED 400/800 / ellk/m 9 LED 400/800 V-CG-S / NE / NE-HT / NIB-HT / NIB-CSA (Zone 1,, 1, ) The efficient solution your explosion-protected lighting concept The explosion-protected

More information

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx) INSTRUCTION MANUAL (ATEX / IECEx) BExBG10D-P and BExBG15D-P Flameproof Xenon Beacons For use in Flammable Gas and Dust Atmospheres BExBG10D-P / BExBG15D-P 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE

More information

HAZARDOUS LOCATION CLASSIFIED AREAS LW1 AND LW2 SERIES DOWN OR UP OPTICS

HAZARDOUS LOCATION CLASSIFIED AREAS LW1 AND LW2 SERIES DOWN OR UP OPTICS H6..H Project: Fixture Type: Location: Contact/Phone: FINIA LED WALL MOUNTED HAZARDOUS LOCATION CLASSIFIED AREAS LW AND LW SERIES DOWN OR UP OPTICS LED W, W, AND 8W PRODUCT DESCRIPTION The Finia LED LW

More information

ATX DPD Series Distribution Panelboards Flameproof

ATX DPD Series Distribution Panelboards Flameproof ATX DPD Series Distribution Panelboards Applications Protection and control of electrical equipment in hazardous areas where ignitable vapors, gases or highly combustible dusts are present. For installation

More information

Code Master 2 Factory Sealed Induction Lighting System Explosionproof

Code Master 2 Factory Sealed Induction Lighting System Explosionproof Code Master 2 Factory Sealed Induction Lighting System Class I, Division 1 and 2, Groups C, D Class II, Division 1 and 2, Groups E, F, G Marine Type Electric Fixtures Outside Type (Salt Water) NEMA 4X

More information

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx) INSTRUCTION MANUAL (ATEX / IECEx) BExBGL2D LED BEACON For use in Flammable Gas and Dust Atmospheres BExBGL2D 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN ENERGIZED POTENTIAL

More information

MVOLT

MVOLT High Lumen LED Flood Luminaire Notes Type Hit the Tab key or mouse over the page to see all interactive elements. Introduction Specifications EPA: 5.4 ft 2 (0.50 m 2 ) Depth: 10 (25.4 cm) Width: 25 (62.5

More information

Lighting: Explosionproof Area HID. Applications. Standard Materials

Lighting: Explosionproof Area HID. Applications. Standard Materials Code Master Jr. HID Factory Sealed Luminaires Integrally Ballasted. 50 W, 70 W, 00 W, 50 W HPS; 50 W, 70 W, 00 W, 75 W PSMH. 75 W MH V. Medium Base. For Use with Threaded Metal Conduit. Class I, Division

More information

Integrated Control modules

Integrated Control modules .60.0 Rev. 0 Page of 9 Integrated Control modules QC, QC2 and QC Features: - Basic actuator functions for: - Spring return applications, or - Double acting applications or, - Double acting Fail in Last

More information

APPLICATIONS APPROVALS. GASKET One piece neoprene. LATCHES Plated steel twist draw. ENTRIES 1 2 NPT feed-through outlets, 3 4 NPT outlets optional.

APPLICATIONS APPROVALS. GASKET One piece neoprene. LATCHES Plated steel twist draw. ENTRIES 1 2 NPT feed-through outlets, 3 4 NPT outlets optional. Haz HazMax Pinnacle/al APPLICATIONS Hazardous locations Watertight requirements Dusttight requirements Oil and gas exploration and production Waste water treatment plants Pipeline compressor / pumping

More information

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D EJB Junction Boxes Cl. I, Div. and 2, Groups B, C, D Cl. II, Div., Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 3, 4, 4X*,, Ex d IIB + H2 T6, IP66 Explosionproof Dust-Ignitionproof Raintight

More information

ALUMINUM OUTLET BODIES

ALUMINUM OUTLET BODIES KILLARK GEB SERIES ALUMINUM OUTLET BODIES * Class I, one I, Groups IIC, IIB, IIA Type 4X Applications GEB series conduit boxes are installed in conduit systems within hazardous areas to: Protect conductors

More information

MA20/MA21 SERIES MAYA - LED Post Top

MA20/MA21 SERIES MAYA - LED Post Top TYPE: QUANTITY: PROJECT: / SERIES Post Top CATALOG NUMBER: FIXTURE WATTAGE VOLTAGE FINISH OPTION OPTION OPTION OPTION 7 1 2 3 4 1- Cast aluminum LED heat sink. 2- Optical system assembly. 3- Set of two

More information

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax , Product description 2 Product key features COOPER Crouse-Hinds EVZ series HID pendant luminaire is Ex de designed with rugged fixture and impact duration tempered glass globe. It has 2 versions with full

More information

CEC: Class I, Division 1 and 2, Groups B, C, D Class II, Division 1 and 2, Groups E, F, G Class III Type 4X Exd IIB + H 2

CEC: Class I, Division 1 and 2, Groups B, C, D Class II, Division 1 and 2, Groups E, F, G Class III Type 4X Exd IIB + H 2 Integrally Ballasted. 50 W, 70 W, 00 W, 50 W HPS; 75 W PSMH. 75 W MH. Medium Base. For Use with Threaded Metal Conduit. Applications For use in chemical and petrochemical plants, such as manufacturers

More information

1SA / ALT3P35/ 120L5K277/ WH/ A26

1SA / ALT3P35/ 120L5K277/ WH/ A26 Date: Jun 20, 2013 1SA/ALT3P70/120L3K240/DB/A-33 BB-SGL-ALT Catalog number: Approvals: Mtg. Fixture Electrical Module Finish Options See page 2 See pages 3-4 Ordering Example: 1SA / ALT3P35/ 120L5K277/

More information

ALUMINIUM AND STAINLESS STEEL ENCLOSURES - EJB... SERIES

ALUMINIUM AND STAINLESS STEEL ENCLOSURES - EJB... SERIES Ex d IIB+H 2 ALUMINIUM AND STAINLESS STEEL ENCLOSURES - EJB... SERIES ALUMINIUM ENCLOSURES STAINLESS STEEL ENCLOSURES EJB... series enclosures offer Ex d IIB +H 2 mode of protection. These enclosures are

More information

SafeSite LED Based Signaling for Hazardous Locations

SafeSite LED Based Signaling for Hazardous Locations SafeSite LED Based Signaling for Hazardous Locations On when it matters most. Products and solutions that protect your business 2 www.dialight.com MDTFSFSTBROCHURE_H Features & Benefits 5 year full performance

More information

Bavaria Downs. Chaska, MN. Lighting

Bavaria Downs. Chaska, MN. Lighting Bavaria Downs Chaska, MN Lighting Jason Kinsella City View Electric, Inc. 14309 Lake Drive NE Columbus, MN 55025 Phone 651.659.9496 Fax 651.659.0905 cityviewelectric.com DESCRIPTION Lumark The Prevail

More information

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY[R] IRON ALLOY (US), COPPER FREE ALUMINUM (CANADA)

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY[R] IRON ALLOY (US), COPPER FREE ALUMINUM (CANADA) 804 South Street 75964-726, TX Nacogdoches Phone: 96-569-794 Fax: 96-560-4685 EDS25 -Gang Start/Stop Station Cooper Crouse-Hinds Catalog Number Manufacturer Weight per unit Product Category Features Assembly/Kit

More information