A26. Aluminium heat exchanger A26
|
|
- Gyles Morris
- 5 years ago
- Views:
Transcription
1 Aluminium heat exchanger A A Before using the heat exchanger, carefully read the document entitled GENERAL OPERATING INSTRUCTIONS FOR HEAT EXCHANGER USE 98SAEEN
2 A V-V Dimensions ± L MAX 99 H ± T Bypass C 8, 89, ± ± 8 ± MX, 8,, N G 8 N Ø ± Code Description Fan FR A EAX V bypass T V.T. bar FR A ESX V bypass T V.T. bar Air flow m³/h Voltage V Amperage A L Max H Weight Kg Capacity l FR A EAX V bypass T VNR. bar FR A ESX V bypass T VNR. bar FR FR A EAX V bypass T V.T. bar A ESX V bypass T V.T. bar FR A EAX V bypass T VNR. bar FR A ESX V bypass T VNR. bar FR A EAP V FR A ESP V FR A EAX V FR A ESX V FR A EAP V FR A ESP V FR A EAX V FR A ESX V SAEEN
3 Characteristic curves V-V A Heat exchange (thermal) capacity Radiator passage pressure drop Temperature difference Constant temperature Constant viscosity [kw] 8 l/min l/min l/min.. T OIL = 8 C cst cst 8 cst µ OIL = cst C 8 C Bypass passage load loss Q = l/min VT thermostatic bypass T = n VNR pressure bypass T = T OIL = C µ OIL = cst d OIL =.87 kg/dm T OIL = C µ OIL = cst d OIL =.87 kg/dm T OIL = C µ OIL = cst d OIL =.87 kg/dm Bypass valves Legend Thermostatic T VT bar,8 Pressure T VNR. bar,8 A E AP SP AX Exchanger type Fan unit High power aspirating High power blower Extra high power aspirating 9 SX Extra high power blower V V M7x M7x T VT Thermostatic bypass valve bar ubc T VNR Pressure bypass valve at. bar 98SAEEN
4 A V-8V Dimensions ± L MAX H ± T Bypass C 8, 8, 89, ± ± 8 ± MX, N G 8 N Ø ± Code Description Ø Fan FR A EA V bypass T V.T. bar FR A ES V bypass T V.T. bar Power W FR A EA V bypass T VNR. bar FR A ES V bypass T VNR. bar FR FR A EA V bypass T V.T. bar A ES V bypass T V.T. bar FR A EA V bypass T VNR. bar FR A ES V bypass T VNR. bar FR A EA V FR A ES V FR A EA V FR A ES V Frequency Hz Velocity min-¹ IP Rating L Max H Weight Kg Capacity l SAEEN
5 Characteristic curves V-8V A Heat exchange (thermal) capacity Radiator passage pressure drop Temperature difference Constant temperature Constant viscosity [kw] 8 l/min l/min l/min.. T OIL = 8 C cst cst 8 cst µ OIL = cst C 8 C Bypass passage load loss Q = l/min VT thermostatic bypass T = n VNR pressure bypass T = T OIL = C µ OIL = cst d OIL =.87 kg/dm T OIL = C µ OIL = cst d OIL =.87 kg/dm T OIL = C µ OIL = cst d OIL =.87 kg/dm Bypass valves Legend Thermostatic T VT bar,8 Pressure T VNR. bar,8 A E AP SP AX Exchanger type Fan unit High power aspirating High power blower Extra high power aspirating 9 SX Extra high power blower V V M7x M7x T VT Thermostatic bypass valve bar T VNR Pressure bypass valve at. bar 98SAEEN
6 A V-8V-B Dimensions ± L MAX H ± T C Bypass 8, 8, 89, ± ± 8 ± MX, N G 8 N Ø ± Code Description Fan FR A EA V-B bypass T V.T. bar FR A EA V-B bypass T VNR. bar FR A EA 8V-B bypass T V.T. bar FR A ES 8V-B bypass T V.T. bar FR A EA 8V-B bypass T VNR. bar FR A ES 8V-B bypass T VNR. bar Power W Frequency Hz Velocity min-¹ IP Rating L Max H Weight Kg Capacity l FR A EA V-B FR A ES V-B FR A EA 8V-B FR A ES 8V-B SAEEN
7 Characteristic curves V-8V-B A Heat exchange (thermal) capacity Radiator passage pressure drop Temperature difference Constant temperature Constant viscosity [kw] 8 l/min l/min l/min.. T OIL = 8 C cst cst 8 cst µ OIL = cst C 8 C Bypass passage load loss Q = l/min VT thermostatic bypass T = n VNR pressure bypass T = T OIL = C µ OIL = cst d OIL =.87 kg/dm T OIL = C µ OIL = cst d OIL =.87 kg/dm T OIL = C µ OIL = cst d OIL =.87 kg/dm Bypass valves Legend Thermostatic T VT bar,8 Pressure T VNR. bar,8 A E AP SP AX Exchanger type Fan unit High power aspirating High power blower Extra high power aspirating 9 SX Extra high power blower V V M7x M7x T VT Thermostatic bypass valve bar ubc T VNR Pressure bypass valve at. bar 98SAEEN
8 A Hydraulic actuation Dimensions 9 ± L MAX 7 Bypass C H ± T 8, 9 ± ± 8 8, ± MX, N G 8 N Ø ± Code Description Ø Fan FR FR FR FR A IA MOT.IDR. GR bypass T V.T. bar A IS MOT.IDR. GR bypass T V.T. bar A IA MOT.IDR. GR bypass T VNR. bar A IS MOT.IDR. GR bypass T VNR. bar Displacement motors cm/h L Max H Weight Kg Capacity FR A IA MOT.IDR. GR FR A IS MOT.IDR. GR l 8 98SAEEN
9 Characteristic curves Hydraulic actuation A Heat exchange (thermal) capacity Radiator passage pressure drop Temperature difference Constant temperature Constant viscosity [kw] min. T OIL = 8 C µ OIL = cst 8 l/min l/min l/min. cst cst 8 cst C 8 C Bypass passage load loss Q = l/min VT thermostatic bypass T = n VNR pressure bypass T = T OIL = C µ OIL = cst d OIL =.87 kg/dm T OIL = C µ OIL = cst d OIL =.87 kg/dm T OIL = C µ OIL = cst d OIL =.87 kg/dm Bypass valves Legend Thermostatic T VT bar,8 Pressure T VNR. bar,8 A E AP SP AX Exchanger type Fan unit High power aspirating High power blower Extra high power aspirating 9 SX Extra high power blower V V M7x M7x T VT Thermostatic bypass valve bar T VNR Pressure bypass valve at. bar 98SAEEN
10 A Accessories Characteristic curves Connector Code AMP connector 898 Left supporting foot Code 8 98 Left supporting foot FR99 8, ± Code Right supporting foot FR9 8, ± 8 98SAEEN
11 Characteristic curves Accessories A Thermostats Ch 9 Trigger temperature C Code - Mx. FR - Mx. FR 8-7 Mx. FR Mx. FR X 8-7 Mx. FR 87. IP protected thermal switch Trigger temperature C Code - Mx. FR - Mx. FR - Mx. FR. Ch 7 - Mx. FR Mx. FR 87 X ø IP protected thermal switch M Trigger temperature C Code - Mx. FR 7 - Mx. FR - Mx. FR Ch Mx. FR 87, 7 X Ø 98SAEEN
A20 A20. Aluminium heat exchanger 398SAE004EN00
Aluminium heat exchanger A A 98SAEEN Before using the heat exchanger, carefully read the document entitled GENERAL INSTRUCTIONS FOR HEAT EXCHANGER USE. 98SAEEN - --7 A V-V Dimensions ± L MAX C 8,, H ±
More informationMaxiflow Series Spin-on Filters Max. 360 I/min - 10 bar
Maxiflow Series Spin-on Filters Max. 36 I/min - 1 bar Designed for both suction and return application Spin-on filters The Maxiflow Series full flow filters for suction or return are designed to provide
More informationFMM bar. Working pressure. Style T. Style D. Style S. Style B D.I. D.I. D.I. D.I.
30 FMM 050 SRIS FMM 050 Working pressure 0 bar Style S Style Style T Style D 3 3 Technical data Filter body (Materials) Head: Cast iron (chemical heat treatment) Housing: Steel (chemical heat treatment)
More information- SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 PERFORMANCE CURVE DWC PERFORMANCE CURVE DWC
CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 300 203 PERFORMANCE CURVE 500 204 - CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL
More information2012 DC Electropumps Bull
1 DC Electropumps Bull sales@hydronit.com +39 3 1841 1 ELECTROPUMPS BULL series ordering codes ELECTROPUMP BULL 8 MODEL CODE EPB8 -,5 4DC /S15 - K1,1 V** Electro Pump Bull 8 series Dc electric motor power
More informationPRA EBAR. RA Pumps Europe S.p.A. CENTRIFUGAL PUMPS CONTENTS. 60Hz. Page - SPECIFICATIONS
CONTENTS Page SPECIFICATIONS 200 PERFORMANCE RANGE and SELECTION CHART 20 TYPE KEY and CURVES SPECIFICATIONS 202 PERFORMANCE CURVES 203 CONSTRUCTIONS SECTIONAL VIEW MECHANICAL SEAL (UP TO 0.75 kw) MECHANICAL
More informationOil/air cooler BLK. Fluidcontrol
Fluidcontrol Oil/air cooler BLK Drives and hydraulic aggregates are used in machine construction, raw material production, maritime and many other areas. In hydraulic systems oil transfers power and motion,
More information- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 MECHANICAL SEAL 302 QUANTITY FOR MODEL 303 BEARINGS 303
CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATION 202 PERFORMANCE CURVE 40/86 203 PERFORMANCE CURVE 40/106 204 PERFORMANCE CURVE 40/126 205 PERFORMANCE CURVE 40/156
More informationDirection Technique et Commerciale Paris 54, Route de Sartrouville F Le Pecq Tel : (+33) ELECTRIC POWER SUPPLIER
Direction Technique et Commerciale Paris ESP 5850 ESE 6850 ELECTRIC POWER SUPPLIER ESP 5850 ESE 6850 Without box In box Output voltage curve Options : Special input voltage Marinised With fan Without fast
More informationETF Series. Tanktop Mounted Return Line Filters max. 175 I/min - 6 bar. An economic return line filter. Product Features: Contact Information:
max. 75 I/min - 6 bar An economic return line filter Improved system protection The ETF Series utilizes a re-inforced co-polymer head equipped with 2 return ports and quick-release cover. Maximum pressure
More informationCooling Systems CC Series TT rail 20/30lpm
CC Series 20/30lpm General Data And Details The oil / air coolers of our CC series are autonomous cooling systems with an integrated circulation pump. They work as a separate cooling unit or as a ilter
More informationDUMPER. Data Book 50 Hz
Data Book 50 Hz CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 CURVE SPECIFICATIONS 203 1X 51-S 204 1X 51.5-S 205 2X 51.5-S 206 2X 52.2-S 207 2X 53-S 208 3X
More informationDUMPER. Data Book 50 Hz
Data Book 50 Hz CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 CURVE SPECIFICATIONS 203 1X 51-S 204 1X 51.5-S 205 2X 51.5-S 206 2X 52.2-S 207 2X 53-S 208 3X
More information- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 MECHANICAL SEAL 302 BEARINGS 303 THERMAL INSULATION 304
CONTENTS 1 Page - SPECIFICATIONS 200 PERFORMANCE RANGE and SELECTION CHART 201 TYPE KEY and CURVES SPECIFICATIONS 202 PERFORMANCE CURVES 300 203 PERFORMANCE CURVES 500 204 - CONSTRUCTIONS 300 SECTIONAL
More informationDirectional Control Valve Series 4D01 (DENISON)
Characteristics The Denison series 4D01 is a solenoid operated directional control valve size NG06 in -chamber design. It is direct operated by wet pin solenoids. The 4D01 is available with a Soft Shift
More informationDUMPER. Data Book 50 Hz
Data Book 50 Hz CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 202 GAMMA 203 CURVE SPECIFICATIONS 204 1X 51-S 205 1X 51.5-S 206 2X 51.5-S 207 2X 52.2-S 208 2X 53-S 209 3X 53.7-S 210 3X
More informationRF2 Maximum pressure 20 bar F l o w r a t e s t o l / m i n
RF2 96 Maximum pressure 20 bar F l o w r a t e s t o 4 5 5 l / m i n Filter housing (Materials) Filter body: luminium over: Nylon Valve: Nylon - Steel nti-emptying valve: Steel Pressure Working pressure:
More information- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 THERMAL INSULATION DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401
CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 70 203 PERFORMANCE CURVE 120 204 PERFORMANCE CURVE 200 205 - CONSTRUCTIONS 300 SECTIONAL VIEW
More informationSINGLE STAGE TWO STAGES
BLOWERS CATALOG Table of contents SINGLE STAGE TWO STAGES 3 4 1 1 5 6 7 8 9 10 11 12 Weight (Kg) 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 2RSC 50-65 Performance curve for Vacuum
More informationMULTIGO. EBARA Pumps Europe S.p.A. CENTRIFUGAL PUMPS. Page
CONTENTS 1 Page - SPECIFICATIONS 200 PERFORMANCE RANGE and SELECTION CHART 201 TYPE KEY and CURVES SPECIFICATIONS 202 PERFORMANCE CURVES 40 203 PERFORMANCE CURVES 80 204 - CONSTRUCTIONS SECTIONAL VIEW
More information22PD/32PD Series High Pressure Duplex Filters Max 260 l/min bar
/ Series Max 26 l/min - 21 bar A duplex design with a wide application capability Designed to offer continuous operation during element change The / Series utilizes a duplex design with integrated balancing
More informationAir Cooler Mobile OK-ELD 0-6 with DC motor
ir ooler Mobile OK-ELD 0-6 with D motor Symbol General The OK-ELD air cooler series is designed specifically for mobile hydraulic applications where high performance and efficiency are required and physical
More informationMATERIALS FILTER PRESSURE VALUES
INTRODUCTION Thanks to many years of in-field experience regarding research, design and production of oil filters and oil separation for compressors applications, the high quality standard reached by FAI
More informationOil/Air Cooler Units. Standard series EL Type. Test procedure certified following EN 1048
COMPLETE OIL / AIR COOLER SYSTEM WITH AXIAL FAN FOR INDUSTRIAL APPLICATIONS. Application These high performance coolers with axial fans are suitable for hydraulic cooling applications with both return
More informationOil/Air Cooler Units. Compact application with AC Motor OK-ELC Type. Test procedure certified following EN 1048
COMPACT OIL / AIR COOLERS NEW COMPACT DESIGN WITH AC ELECTRIC FANS AND HIGH COOLING PERFORMANCE Application These coolers are designed specifically for hydraulic applications where high performance and
More information- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 MECHANICAL SEAL 302 BEARINGS 303
CONTENTS Page - SPECIFICATIONS 200 PERFORMANCE RANGE and SELECTION CHART 201 TYPE KEY and CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 0.50 203 PERFORMANCE CURVE 0.80 204 PERFORMANCE CURVE 1.00 205 PERFORMANCE
More informationAir Cooled Exchangers With Aluminium Cooling Elements
AIR COOLED Versacool Series Cooler AC electric models deliver more air flow resulting in greater performance while using a smaller diameter lower noise fan. Cylindrical air jet discharge pattern eliminates
More informationOil/air cooler BLK ATEX-3GD
FluidControl Oil/air cooler BLK ATEX-3GD Drives and hydraulic aggregates are also used in explosive areas in machine construction or raw material production. In hydraulic systems oil transfers power and
More informationAir Cooler Industry AC-LN 8-14 / ACA-LN 8-11 / ACAF-LN 8-11
Air Cooler Industry AC-LN 8-14 / ACA-LN 8-11 / ACAF-LN 8-11 Symbol General The AC-LN 8-14 air cooler series can be used in all areas where either oil or water-glycol is to be cooled with air. The coolers
More information- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 BEARINGS DIMENSIONS and WEIGHT 400 PUMP 400 PACKING 401
CONTENTS 1 Page - SPECIFICATIONS 200 PERFORMANCE RANGE and SELECTION CHART 201 TYPE KEY and CURVES SPECIFICATIONS 202 PERFORMANCE CURVES 076 203 PERFORMANCE CURVES 106 204 - CONSTRUCTIONS 300 SECTIONAL
More informationAir Cooled Exchangers With Aluminium Cooling Elements
AIR COOLED Versacool Series Cooler AC electric models deliver more air flow resulting in greater performance while using a smaller diameter lower noise fan. Cylindrical air jet discharge pattern eliminates
More informationFlow Control Valve. 1 Description. 2 Symbols. Series SRCA General. 1.2 Application examples way flow control way flow control
Flow Control Valve Series SRC.. plug-in coil for easy coil change flow rates are unaffected by changes in temperature or load compact design reduced p ZnNi coating (>70h DIN EN ISO 97 NSS) Description.
More informationAN INNOVATIVE GREEN FILTER FEATURING LEIF LEIF. Product Features:
Max. I/min - bar When an all-in-one solution matters Reduction of reservoir accessories The Tanktopper Series features an integrated, micron Abs. air breather. Maximum pressure bar. Maximum flow l/min.
More informationAN INNOVATIVE GREEN FILTER FEATURING LEIF LEIF. Product Features:
Max 5 I/min - bar Featuring prefiltration by means of a magnetic column Extended element life time AN INNOVATIVE GREEN FILTER FEATURING LEIF LEIF The TTF Series features pre-filtration by means of a magnet
More informationCMA-B-C-D. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page
CONTENTS Page - SPECIFICATIONS 200 PERFORMANCE RANGE 201 SELECTION CHART 202 TYPE KEY 203 CURVE SPECIFICATIONS 203 PERFORMANCE CURVE CMA 204 PERFORMANCE CURVE CMB 205 PERFORMANCE CURVE CMC 206 PERFORMANCE
More information200 PERFORMANCE RANGE and SELECTION CHART 201 TYPE KEY and CURVES SPECIFICATIONS SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE
CONTENTS Page - SPECIFICATIONS 200 PERFORMANCE RANGE and SELECTION CHART 20 TYPE KEY and CURVES SPECIFICATIONS 202 PERFORMANCE CURVES 300 203 PERFORMANCE CURVES 500 204 - CONSTRUCTIONS 300 SECTIONAL VIEW
More informationPage - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 202 CURVE SPECIFICATIONS 203 PERFORMANCE CHART COMPACT A 204 PERFORMANCE CHART COMPACT B 205
CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 202 CURVE SPECIFICATIONS 203 PERFORMANCE CHART A 204 PERFORMANCE CHART B 205 - CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEALS 301
More information- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL DIMENSIONS AND WEIGHT 400 PUMP 400 GEOMETRIC TOLERANCES 401 PACKING 402
CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 1506 203 PERFORMANCE CURVE 2006 203 PERFORMANCE CURVE 3006 203 PERFORMANCE CURVE 4006 203
More information- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 BEARINGS 302 MECHANICAL SEALS 303 DIAGRAM AND ELECTRIC CONNECTIONS 304
CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 202 PERFORMANCE CHART A (up to 0.6 kw) 203 PERFORMANCE CHART A (from 0.75 kw up to 1.1 kw) 204 PERFORMANCE CHART A (1.3 kw) 205 PERFORMANCE
More information- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 BEARINGS DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401
CONTENTS Page - SPECIFICATIONS 200 PERFORMANCE RANGE and SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 0.75 203 PERFORMANCE CURVE 1.00 204 - CONSTRUCTIONS 300 SECTIONAL VIEW
More informationPilot Operated Pressure Relief Valve Series R5V (Denison)
Characteristics Pilot operated pressure relief valves series R5V have a similar design to the subplate mounted R4V series. The SAE flanges allow to mount the valves directly on the outlet flanges of pumps
More informationOff-line filter / cooler unit FGSL
Fluidcontrol Off-line filter / cooler unit FGSL Coolers are used to stabilise the operating temperature in hydraulic and lubrication systems. This can be implemented particularly cost-efficiently by integrating
More information- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 BEARINGS DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401
CONTENTS 1 Page - SPECIFICATIONS 200 PERFORMANCE CURVE and SELECTION CHART 201 TYPE KEY and CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 076 203 PERFORMANCE CURVE 106 203 PERFORMANCE CURVE 156 203 PERFORMANCE
More informationOil/air cooler BLK. Fluidcontrol
Fluidcontrol Oil/air cooler BLK Drives and hydraulic aggregates are used in machine construction, raw material production, maritime and many other areas. In hydraulic systems oil transfers power and motion,
More informationMODEL DIMENSIONS, mm WEIGHT OIL FILL L W H A B C D E kg l HK 450/ x ,9
1 Dynaset HK hydraulic compressor gives high quality, efficient compressed air to different kinds of applications; pneumatic tools, air flushing, tire filling, cleaning, etc. Compact hydraulic air compressor
More informationMODEL DIMENSIONS, mm WEIGHT OIL FILL L W H A B C D E kg l HK 450/ x ,9
1 Dynaset HK hydraulic compressor gives high quality, efficient compressed air to different kinds of applications; pneumatic tools, air flushing, tire filling, cleaning, etc. Compact hydraulic air compressor
More informationTXV - Characteristics
TXV - Characteristics TXV pumps are available in 11 models from to 150 cc/rev maximum displacement. Pump reference Direction of rotation Maximum displac. (1) Max. operating pressure Max. peak pressure
More informationMPH Maximum pressure 10 bar F l o w r a t e s t o l / m i n
MPH Maximum pressure bar F l o w r a t e s t o l / m i n 6 echnical data housing (Materials) Head: luminium: MPH ---- nodised luminium: MPH 6-8 Painted luminium: MPH 66 Cover: Nylon: MPH --- luminium:
More informationPage - DIMENSIONS AND WEIGHT 400 PUMP MATRIX PUMP DRAWING MATRIX 5/10/ PUMP TABLE MATRIX 5/10/ PACKING 403
CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 SELECTION CHART TABLE 202 TYPE KEY AND CURVE SPECIFICATIONS 203 PERFORMANCE CURVE 3 ( 2-3 IMPELLERS ) 204 PERFORMANCE CURVE 3 ( 4-5-6 IMPELLERS )
More informationAir Cooled Exchangers With Aluminium Cooling Elements DC ELECTRIC HEAT EXCHANGERS
COOLED DC ELECTRIC HEAT EXCHANGERS Total of 4 stock models including and 4 volts. DB models are standard performance with fully weather proofed fans with interference suppression. DA models are high performance
More informationHeat Exchangers. Evaporator Catalogue
Heat Exchangers Evaporator Catalogue Version 30: January 2015 Heat Exchangers Thermocoil Catalogue V30 2015 Evaporators Page 2 INDEX EVAPORATORS PAGE Evaporator Design and Info 4 Quick Find List (Sorted
More informationOil/Air Cooler Units. Compact application with AC Motor OK-ELC Type
COMPACT OIL / AIR COOLERS NEW COMPACT DESIGN WITH AC ELECTRIC FANS AND HIGH COOLING PERFORMANCE Application These coolers are designed specifically for hydraulic applications where high performance and
More informationFlow Control Valve. 1 Description. 2 Symbols. Series SRCA General. 1.2 Application examples way flow control way flow control
Flow Control Valve Series SRC.. plug-in coil for easy coil change flow rates are unaffected by changes in temperature or load. compact reduced p ZnNi coating (>70h DIN EN ISO 97 NSS) Description. General
More informationKVA POWERHOUSE RANGE 1250 KVA 1700 KVA
KVA POWERHOUSE RANGE 1250 KVA 1700 KVA 50 hz Three phase 380-415 v Model Engine Alternator Manufacturing country of engine & alternator PRP Output ESP Output Kva Kw Kva 380v/400- Kw 415v 46TWG2A PI734B
More informationMPH Maximum pressure 10 bar F l o w r a t e s t o l / m i n
MPH Maximum pressure bar F l o w r a t e s t o l / m i n 6 echnical data Filter housing (Materials) Head: luminium: MPH ---- nodised luminium: MPH 6-8 Painted luminium: MPH 66 Cover: Nylon: MPH --- luminium:
More informationIn-Line Filters. Section Index. High FPK
Hydraulic In-Line Filters Section Index NEW Medium Pressure Filters FMK-FM............................ FCK-LC............................. 123 HMK04 Duramax.................... 124 HMK05 Duramax....................
More informationServo solenoid valves with on-board electronics (OBE)
Servo solenoid valves with on-board electronics (OBE) RE 29045/10.05 Replaces: 01.05 1/12 Type 5WRPE 10 Size 10 Unit series 2X Maximum working pressure P 1, P 2, A, B 210 bar, T 50 bar Nominal flow rate
More information- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 BEARINGS DIMENSIONS AND WEIGHT 400 PUMP 400 GEOMETRIC TOLERANCES 401 PACKING 402
CONTENTS Page - SPECIFICATIONS 200 PERFORMANCE RANGE and SELECTION CHART 201 TYPE KEY and CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 150 203 PERFORMANCE CURVE 200 204 PERFORMANCE CURVE 300 205 PERFORMANCE
More information- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401
CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 70 203 PERFORMANCE CURVE 120 204 PERFORMANCE CURVE 200 205 - CONSTRUCTIONS 300 SECTIONAL VIEW
More information- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL 303 BEARINGS 304 FITTINGS 305
CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 SELECTION CHART TABLE 202 TYPE KEY AND CURVE SPECIFICATIONS 203 PERFORMANCE CURVE 3 ( 3-4-5-6 IMPELLERS ) 205 PERFORMANCE CURVE 3 ( 7-8-9 IMPELLERS
More information- CONSTRUCTIONS 300 SECTIONAL VIEW 300 THERMAL INSULATION 301 MECHANICAL SEAL 302 BEARINGS DIMENSIONS and WEIGHT 400 PUMP 400 PACKING 401
CONTENTS 1 Page - SPECIFICATIONS 200 PERFORMANCE RANGE and SELECTION CHART 201 TYPE KEY amd CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 70 203 PERFORMANCE CURVE 120 204 PERFORMANCE CURVE 200 205 - CONSTRUCTIONS
More information- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 BEARINGS DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401
CONTENTS Page - SPECIFICATIONS 200 PERFORMANCE RANGE and SELECTION CHART 201 TYPE KEY and CURVE SPECIFICATIONS 202 PERFORMANCE CURVE AGA 0.60 203 PERFORMANCE CURVE AGA 0.75 204 PERFORMANCE CURVE AGA 1.00
More information22PD/32PD Series. High Pressure Duplex Filters. A duplex design with a wide application capability. Product Features: Contact Information:
/ Series High Pressure Duplex Filters A duplex design with a wide application capability Designed to offer continuous operation during element change The / Series utilizes a duplex design with integrated
More informationRIELLO 40 F SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL. F kw F kw F kw
The Riello 40 F series of one stage light oil burners, is a complete range of products developed to respond to any request for light industrial applications. The Riello 40 F series is available in three
More information- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 BEARINGS DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401
CONTENTS Page - SPECIFICATIONS 200 PERFORMANCE RANGE and SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 0.75 203 PERFORMANCE CURVE 1.00 204 PERFORMANCE CURVE 1.50 205 PERFORMANCE
More informationFPK 02 AP280. Pressure Line High Pressure Filters In-Line up to 420 bar. Mix&Match to Get What You Need
FPK 02 AP280 Pressure Line High Pressure Filters In-Line up to 420 bar Mix&Match to Get What You Need Donaldson's Mix&Match system provides the great performance and functional advantages of custom-engineered
More informationELH Series - Hydraulic Fan Drive
- Hydraulic Fan Drive ir ooled Oil oolers for Mobile pplications Description These coolers use a combination of high performance cooling elements combined with a high capacity hydraulic fan drive to give
More information3D SERIES. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page
CONTENTS Page - SPECIFICATIONS 0 SELECTION CHART 1 TYPE KEY 3 PERFORMANCE CURVE SPECIFICATIONS 4 PERFORMANCE CURVE 32-125 5 PERFORMANCE CURVE 32-6 PERFORMANCE CURVE 32-0 7 PERFORMANCE CURVE 40-125 8 PERFORMANCE
More informationOil/Air Cooler Units. Standard series OK-P type. Test procedure certified following EN
COMPLETE OIL / AIR COOLER WITH AXIAL FAN FOR INDUSTRIAL APPLICATIONS. Application These high performance coolers with axial fans are suitable for hydraulic cooling applications. Typical applications include:
More informationFlow rates to 500 l/min
FF 5 Filter housing in according to SE J066 for F filter elements Maximum pressure 50 bar Flow rates to 500 l/min Technical data Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing:
More information2CDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page
CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 70 203 PERFORMANCE CURVE 120 204 PERFORMANCE CURVE 200 205 - CONSTRUCTIONS 300 SECTIONAL VIEW
More information- CONSTRUCTIONS 300 SECTIONAL VIEW 300 CONSTRUCTIONS 301 CONSTRUCTIONS 302 MECHANICAL SEAL 303 COUNTERFLANGE 304
CONTENTS Page - SPECIFICATIONS 200 PUMP SPECIFICATION 200 TYPE KEY 201 SELECTION CHART 202 SELECTION CHART 203 PERFORMANCE CURVE 3 ( 3-4-5-6 impellers ) 204 PERFORMANCE CURVE 3 ( 7-8-9 impellers ) 205
More informationblue series bluepro series
5Hz water solutions blue series bluepro series DG blue DR blue DG bluepro DR bluepro GR bluepro AP bluepro D a t a b o o k l e t EN water solutions blue series bluepro series DG blue DR blue DG bluepro
More information- DIMENSIONS AND WEIGHT 400 PUMP DUMPER 1X SERIES 400 PUMP DUMPER 2X SERIES 401 PUMP DUMPER 3X, 4X, 5X, 6X, 7X, 8X SERIES 402 PACKING 403
CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 204 GAMMA 205 CURVE SPECIFICATIONS 206 PERFORMANCE CURVE 1X 207 PERFORMANCE CURVE 2X 208 PERFORMANCE CURVE 3X 53.7 209 PERFORMANCE CURVE
More informationDirectional Control Valve Series D3W (Parker), 4D02 (Denison)
Characteristics Series D3W (Parker), 4D0 (Denison) The direct operated directional control valve size NG10 is available with both Parker (series D3W) and Denison (series 4D0) model codes. Both series are
More information- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 BEARINGS 302 MECHANICAL SEAL 303 FITTINGS 304
CONTENTS 1 Page - SPECIFICATIONS 200 PERFORMANCE RANGE and SELECTION CHART 201 TYPE KEY and CURVES SPECIFICATIONS 202 PERFORMANCE CURVES 32-250/7.56 203 PERFORMANCE CURVES 32-250/9.26 203 PERFORMANCE CURVES
More informationCoolers. OK Series. Air Cooled Oil Coolers Hydraulic Symbol OK 1-11 OKF Cooling Systems Catalog. Applications
OK Series Air Cooled Oil Coolers Hydraulic Symbol OK 1-11 OKF 3-11 OKA 4-6 OKAF 4-6 OKA 8-11 OKAF 8-11 Description The OK Series cooler design uses a axial fan assembly which draws air through the cooler.
More information2/2-way and 3/2-way Normally Closed (NC) and Normally Open (NO)
Series CFB solenoid valves /-way and 3/-way Normally Closed (NC) and Normally Open (NO)»» Solenoid valves for air and water»» Great reliability over time, even in heavy working conditions The valve function
More information- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING TECNICAL DATA 500 MOTOR DATA 500
CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 056 203 PERFORMANCE CURVE 066 204 PERFORMANCE CURVE 086 205 - CONSTRUCTIONS 300 SECTIONAL
More informationREVERSIBLE HYDRAULIC POWER PACKS. 1 node/142/
REVERSIBLE HYDRAULIC POWER PACKS 1 node/142/ 2 Introduction Oil Sistem is a leader in power packs production and offers a wide range of solutions suitable for every type of application. Oil Sistem developed
More informationOil/Air Cooler Units. Mobile series with DC motor OK-ELD Type. Test procedure certified following EN 1048
MOBILE OIL / AIR COOLERS NEW COMPACT DESIGN WITH DC ELECTRIC FANS AND HIGH COOLING PERFORMANCE Application These coolers are designed specifically for mobile hydraulic applications where high performance
More informationA complete line of pressure differential visual and electrical indicators are available with this series of filters.
D e s c r i p t i o n FHB series filters are designed for pressure line applications where manifold mounting is a specific requirement. The manifold type filters are designed to integrate onto manifold
More informationAN INNOVATIVE GREEN FILTER FEATURING
When an all-in-one solution matters Reduction of reservoir accessories LEIF AN INNOVATIVE GREEN FILTER FEATURING LEIF LEIF Contact Information: Hydraulic European Product Information Centre Freephone:
More informationGLOBAL STANDARD COOLER
GLOBAL STANDARD COOLER A A OIL-to-AIR COOLING SYSTEMS WITH AC-MOTOR Product Information AKG-Line is a standard line of products from the market leader in high performance aluminium cooling systems. AKG
More informationSeries PD directly operated solenoid valves
> Series PD solenoid valves CATALOGUE > Release 8.8 Series PD directly operated solenoid valves /-way - Normally Closed (NC) Please note that all Series PD solenoid valves are supplied with direct current
More informationHydraulic gear pumps and motors
PL 01 T E DISPLACEMENTS From To Hydraulic gear pumps and motors 0.07 in 3 /rev (1.07 cm 3 /rev) 5.56 in 3 /rev (91.10 cm 3 /rev) through bore aluminum body PRESSURE Max. Continuous Max. Intermittent Max.
More informationFlow sharing control block in mono block / sandwich plate design M6-15
Flow sharing control block in mono block / sandwich plate design M6-15 RE 64321 Edition: 01.2015 Replaces: 05.2012 Size 15 Series 3X Maximum operating pressure on pump side 350 bar on consumer side 420
More informationOFFLINE SERIES GLOBAL STANDARD COOLER
OFFLINE SERIES GLOBAL STANDARD COOLER OIL-TO-AIR COOLING SYSTEMS WITH AC-MOTOR AND PUMP Product information AKG-Line is a standard line of products from the market leader in high performance aluminium
More information- SPECIFICATIONS SPECIFICATIONS 200 SELECTION CHART 201 PERFORMANCE CHART MULTIGO PERFORMANCE CHART MULTIGO
CONTENTS Page - CONTENTS CONTENTS 100 - SPECIFICATIONS SPECIFICATIONS 200 SELECTION CHART 201 PERFORMANCE CHART 40 202 PERFORMANCE CHART 80 203 - CONSTRUCTIONS CONSTRUCTIONS 300 CONSTRUCTIONS 301 CONSTRUCTIONS
More information822 NOVAMIX GAS FLOW RATE ADJUSTMENT AS A FUNCTION OF THE AIR FLOW GAS/AIR RATIO 1:1 DOUBLE AUTOMATIC SOLENOID SHUT-OFF VALVE
SIT Group 822 NOVAMIX MULTIFUNCTIONAL GAS CONTROL GAS FLOW RATE ADJUSTMENT AS A FUNCTION OF THE AIR FLOW GAS/AIR RATIO 1:1 DOUBLE AUTOMATIC SOLENOID SHUT-OFF VALVE SERVO-CONTROLLED PRESSURE REGULATOR PIN
More informationSeated valve bidirectional Type WVM-4B-Bi
Seated valve bidirectional Type WVM-4B-Bi Features Bidirectional (flow of fluid in both directions, independently of pressure prof) Low pressure drop Direct operated Leakage free Good resistance to corrosion
More informationAutomatic back-flushing filter AutoFilt RF4
Automatic back-flushing filter AutoFilt RF4 RF4-1 RF4-2 Specifications Nominal size: G1 G 1½ Q max: 220 l/min p max: 16 bar Filtration ratings: 30 1000 µm 1. GENERAL Product description Self-cleaning automatic
More information- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL and BEARINGS DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401
CONTENTS Page - SPECIFICATIONS 200 PERFORMANCE RANGE and SELECTION CHART 201 TYPE KEY and CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 80 203 PERFORMANCE CURVE 100 204 PERFORMANCE CURVE 120 205 PERFORMANCE
More informationTPV Variable Displacement Axial Piston Pumps CONTENTS. General Information. Installation Instructions. Technical Specifications 6-7
CONTENTS General Information Installation Instructions Technical Specifications Single Pump Installation Drawing Tandem Pump Installation Drawing Mounting Flanges and Shaft Details Rear Pump Mounting Flanges
More informationUnobox units with backward curved centrifugal impellers
Unobox Fans Unobox units with backward curved centrifugal impellers Type Code UNO 67-450 -4 E W Unobox Box size 50=500mm ; 67=670mm 80=800mm ; 102=1020mm Impeller diameter Number of poles D - Three Phase
More informationDirectional Control Valve Series D3W Soft Shift
Characteristics The D3W is a 3-chamber, electrically controlled 4/3 or 4/ way directional control valve. It is activated directly by solenoids with screwed in wet pin armature. The soft shifting of this
More information- CONSTRUCTIONS 300 SECTIONAL VIEW 300 SECTIONAL VIEW TABLE 301 MECHANICAL SEAL 302 FITTINGS DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401
CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 SELECTION CHART TABLE 202 TYPE KEY AND CURVE SPECIFICATIONS 203 PERFORMANCE CURVE 25/08 204 PERFORMANCE CURVE 25/15 205 PERFORMANCE CURVE 25/25 206
More informationWorking pressure. 350 bar. Style B Series FHD 051. Series FHD 325/332 D.I. D.I. D.I. A A
98 FD SRIS FD Working pressure 350 bar Style S Style Series FD 05 Style Series FD 35/33 D.I. D.I. D.I. 99 Technical data body (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical
More informationSuction Return Series
Tanktop Mounted Suction & Return Line Filters - Types SR1 & MAX 25 I/min - 1 bar AN INNOVATIVE GREEN FILTER FEATURING LEIF LEIF 53 Tanktop Mounted Suction & Return Line Filters - Types SR1 & Features &
More informationIN-LINE CENTRIFUGAL DUCT FANS VT Series
IN-LINE CENTRIFUGAL DUCT FANS VT Series DESCRIPTION The VT series of circular in-line duct centrifugal fans consists of model variations within nominal model sizes of,,,,, and mm respectively. The VT range
More information