1 ir ooler Mobile OK-ELD 0-6 with D motor Symbol General The OK-ELD air cooler series is designed specifically for mobile hydraulic applications where high performance and efficiency are required and physical size must be minimized to allow easy installation. Product Features These coolers use a combination of high performance cooling elements and high capacity, long life D electric powered fans to give long trouble free operation in arduous mobile hydraulic applications. The compact design allows the coolers to fit most equipment and provide the highest cooling performance in heat dissipation whilst minimizing space required. l ompact, efficient, high performance l ooling range 2-34 kw l D motors in 12 Volt and 24 Volt with motor lifetimes up to 16,000 hours pplication Field Hydraulic systems in mobile machines and vehicles, such as l Mobile cranes l oncrete mixers and pump trucks l Road paving machines l onstruction machines (excavators, wheel loaders) l gricultural machines l Municipal machines Operation Data Fluids Viscosity Temperature range Pressure resistance of the cooling element Fan Motor Noise levels ccessories l Oils (mineral oils, synthetic oils, high viscosity oils, biological oils, phosphate ester) l Water-glycol (cooling fluids) l HF pressure fluids 2,000 mm²/s (standard) l Minimum / maximum ambient temperature: - 20 to + 40 (standard) l Minimum / maximum temperature of the medium: + 20 to Please contact the technical sales department in the event of deviating temperatures. Notice! Fan at max. speed (max. volume of air) must be avoided when operating a cooler at which the temperature difference between the medium inlet at the cooler and the ambient temperature can be greater than 50. Quick changes in the temperature of the cooling element material can lead to a significant reduction in service life or to direct damage of the cooling element due to thermal shock. Please contact the technical sales department to receive information about controlled fan drives. l Dynamic operating pressure: 16 bar l Static operating pressure: 21 bar xial fan in suction version (standard) xial fan in pushing version on request (note: approx. 10 % less cooling capacity) l D motor l 12 V / 24 V l Protection class IP68 l Insulation class F Other versions on request. See technical data The noise levels are only reference values as the acoustic properties of a room, connections and reflection have an effect on the noise level. l Integrated pressure bypass valve (IP) or integrated thermal pressure bypass valve (IT) (cannot be retrofitted, also see options) l rushless fan l Electronic speed control (ES) l Thermostats l ir filter grid or air filter mat l Vibration damper 1
2 Options Integrated pressure bypass valve (IP) / Integrated thermal pressure bypass valve (IT) The bypass channel is integrated in the cooling element. If a particular pressure is exceeded, the IP opens the bypass channel, thereby protecting the cooling element from too high a pressure. Furthermore, the IT only opens the cooling element path once a particular temperature has been reached. Design OK-ELD 0 ir cooler with 1 xial fan with integrated motor 2 Fan housing 3 Heat exchanger OK-ELD 1.5 ir cooler with 1 xial fan with integrated motor 2 Fan housing 3 Heat exchanger
3 Design OK-ELD ir cooler with 1 xial fan with integrated motor 2 Fan housing 3 Heat exchanger OK-ELD 5-6 ir cooler with 1 xial fan with integrated motor 2 Fan housing 3 Heat exchanger
4 Technical Data OK-ELD 0-6 Type of cooler P/N Voltage [V] Fluid flow [l/min] 1) ir flow [m 3 /h] kw Fan motor: Power / current absorption [kw / ] 2) Recommended Fuse [] Fan Diameter [mm] 2) Noise level (at 1 m distance) [d()] Volume [l] 3) Weight [kg] 4) OK-ELD OK-ELD OK-ELD OK-ELD OK-ELD OK-ELD OK-ELD OK-ELD OK-ELD , OK-ELD , OK-ELD , OK-ELD , OK-ELD , OK-ELD , OK-ELD , x OK-ELD , x OK-ELD , x OK-ELD , x ) Max. flow rate 2) OK-ELD 5-6: each fan 3) Fluid in cooling element 4) Unfilled ounter connector Type of cooler P/N OK-ELD 0 12 V V OK-ELD 1 12 V / 24 V OK-ELD V / 24 V OK-ELD 2 12 V / 24 V OK-ELD 3 12 V / 24 V OK-ELD 4 12 V / 24 V OK-ELD V / 24 V OK-ELD 5 12 V / 24 V (2x) OK-ELD 6 12 V / 24 V (2x)
5 ooling apacity and Pressure Difference Δp OK-ELD ,0 ooling capacity: Dependent on the oil flow rate and the temperature difference ΔT between oil inlet and air inlet. Heat ΔT = 40 [kw] OK-ELD 6 OK-ELD 5 OK-ELD 4.5 OK-ELD 4 OK-ELD 3 0,9 0,8 0,7 0,6 0,5 0,4 0,3 Specific heat dissipation [kw/k] Note: The values are measured at ΔT = 40. For smaller ΔT values, the values can change. You can also use our cooler calculation software for designing. Please contact our technical sales department OK-ELD 0 OK-ELD 2 OK-ELD 1.5 OK-ELD ,2 0,1 Tolerance: % Oil flow [l/min] Pressure difference Δp 2.4 OK-ELD 0 OK-ELD 0 OK-ELD 1.5 Pressure drop [bar] OK-ELD 6 OK-ELD 5 OK-ELD 4 OK-ELD 2 OK-ELD 3 OK-ELD Oil flow [l/min] measured at 30 mm²/s Tolerance: ±5 % For other viscosities, the pressure loss must be multiplied by the conversion factor K: Viscosity (mm²/s) Factor K
6 Model Type ooler type OK-ELD = Oil-ir cooler Size / motor speed 0-6 = size H = 2 pl (3,000 min -1 ) Revision Motor voltage 12 V = 12 V D 24 V = 24 V D 12 VL = 12 V D brushless 24 VL = 24 V D brushless olor 1 = RL 9005 (standard) Other colors on request. ir flow direction S = Suction (standard) D = lowing ccessories IP = Heat exchanger with integrated bypass valve IT = Heat exchanger with integrated thermo-bypass valve ITF = Thermostat (fixed) ES = Electronic speed control For all possible accessories, like vibration absorber, air filter grid or air filter mat, please refer to brochure ccessories for air coolers. OK-ELD - 1H VL S - ITF60 6
7 Dimensions OK-ELD 0 /2 /2 ROTTION Z1 (2x) E2 E1 E5 (4x) Ø F Dimensions OK-ELD 1.5 E1 Z3 /2 /2 Z1 (2x) ROTTION E2 (4x) Ø F E5 7
8 Dimensions OK-ELD 1-4 ROTTION Z3 /2 (6x) Ø F /2 HYD HYD [mm] ±5 ± 10 ±5 E1 E2 E5 ± 2 F ø / slot OK-ELD G½" OK-ELD ) 9.0 M22x1.5 M22x1.5 OK-ELD M8 M22x1.5 M14x1.5 OK-ELD x10 G1" M22x1.5 OK-ELD x10 G1" M22x1.5 OK-ELD x10 G1" M22x1.5 2) OK-ELD ) 12.0 G1-¼" M22x1.5 2) 1) OK-ELD 1 and OK-ELD 4.5 have only the four external fixing points 2) OK-ELD 4 and OK-ELD 4.5 have two connections M22x1.5 Z1 Z3 E2 E1 Z1 (2x) 8
9 Dimensions OK-ELD 5-6 E5 E5 E5 Z3 /2 (8x) Ø F /2 ROTTION ROTTION HYD E1 E2 Z1 (2x) [mm] ±5 ± 10 ±5 E1 E2 E5 ± 2 F ø / slot OK-ELD x20 G1-¼" M22x1.5 OK-ELD x21 G1-¼" M22x1.5 Z1 Z3 Note: We recommend maintaining a minimum distance to ensure an unimpeded air inlet and air outlet. This is half the height of the cooling element (/2). nything below the minimum distance can influence the cooling capacity and the noise emissions. 9
10 Note The information in this brochure relates to the operating conditions. For applications and operating conditions not described, please contact the relevant technical department. Subject to technical modifications. HYD OOLING GMH Industriegebiet Sulzbach/Saar Germany Tel.: Fax: Internet: HYD G Mezzovico ranch Via Sceresa, Zona Industriale Mezzovico Switzerland Tel.: Fax: info@hydac.ch Internet: 10
Air Cooler Mobile AC-LNH 8-14 with hydraulic motor
ir Cooler Mobile C-LNH 8-1 with hydraulic motor Symbol General The C-LNH air cooler series is designed specifically for mobile hydraulic systems where high performance and efficiency are required and physical
More informationAir Cooler Industry AC-LN 8-14 / ACA-LN 8-11 / ACAF-LN 8-11
Air Cooler Industry AC-LN 8-14 / ACA-LN 8-11 / ACAF-LN 8-11 Symbol General The AC-LN 8-14 air cooler series can be used in all areas where either oil or water-glycol is to be cooled with air. The coolers
More informationOil/Air Cooler Units. Mobile series with DC motor OK-ELD Type. Test procedure certified following EN 1048
MOBILE OIL / AIR COOLERS NEW COMPACT DESIGN WITH DC ELECTRIC FANS AND HIGH COOLING PERFORMANCE Application These coolers are designed specifically for mobile hydraulic applications where high performance
More informationFeed Pumps VP / VPB / VPBM
Feed Pumps VP / VPB / VPBM Symbol General The feed pumps from the VP series are low-noise, single-stroke vane pumps with constant flow rate. Using a damped bell housing (PT) enables noise levels to be
More informationOil/Air Cooler Units. Compact application with AC Motor OK-ELC Type. Test procedure certified following EN 1048
COMPACT OIL / AIR COOLERS NEW COMPACT DESIGN WITH AC ELECTRIC FANS AND HIGH COOLING PERFORMANCE Application These coolers are designed specifically for hydraulic applications where high performance and
More informationELD Series - DC Motor Drive
ELD Series - D Motor Drive ir ooled Oil oolers for Mobile pplications Description These coolers use a combination of high performance cooling elements and long life D electrical powered fans to give extended
More informationOil/Air Cooler Units. Compact application with AC Motor OK-ELC Type
COMPACT OIL / AIR COOLERS NEW COMPACT DESIGN WITH AC ELECTRIC FANS AND HIGH COOLING PERFORMANCE Application These coolers are designed specifically for hydraulic applications where high performance and
More informationOil/Air Cooler Units. Mobile application and Hydraulic motor OK ELH Type. Test procedure certified following EN 1048
MOBILE OIL / AIR COOLERS NEW COMPACT DESIGN WITH HYDRAULIC MOTOR AND HIGH COOLING PERFORMANCE Application These coolers are designed specifically for mobile hydraulic applications where high performance
More informationELD Series - DC Motor Drive
ELD Series - D Motor Drive ir ooled Oil oolers for Mobile pplications Description These coolers use a combination of high performance cooling elements and long life D electrical powered fans to give extended
More informationELH Series - Hydraulic Fan Drive
- Hydraulic Fan Drive ir ooled Oil oolers for Mobile pplications Description These coolers use a combination of high performance cooling elements combined with a high capacity hydraulic fan drive to give
More informationOil/Air Cooler Units. Standard series OK-P type. Test procedure certified following EN
COMPLETE OIL / AIR COOLER WITH AXIAL FAN FOR INDUSTRIAL APPLICATIONS. Application These high performance coolers with axial fans are suitable for hydraulic cooling applications. Typical applications include:
More informationOil/Air Cooler Units. Standard series EL Type. Test procedure certified following EN 1048
COMPLETE OIL / AIR COOLER SYSTEM WITH AXIAL FAN FOR INDUSTRIAL APPLICATIONS. Application These high performance coolers with axial fans are suitable for hydraulic cooling applications with both return
More informationOil/Air Cooler Units
COMPLETE OIL / AIR COOLER SYSTEM WITH AXIAL FAN FOR INDUSTRIAL APPLICATIONS. General description In hydraulic systems energy is transformed and transmitted. During this process, efficiency losses occur,
More informationOil/Air Cooler Units Standard series - Accessories
Oil/Air Cooler Units Standard series - Accessories In many industrial applications the Oil/Air coolers require accessories, either controlling or protecting the cooler and the hydraulic system. The accessories
More informationHEAT EXCHANGERS AIR/OIL TYPE LAC. - ATEX Version. Approved for applications where there may be an explosive environment above ground.
Heat exchangers Air/Oil LAC - LAC with AC Motor for Industrial Use - Maximum cooling capacity 300 kw Heat exchangers Air/Oil LAC-X - ATEX Version. Approved for applications where there may be an explosive
More informationOil/air cooler BLK. Fluidcontrol
Fluidcontrol Oil/air cooler BLK Drives and hydraulic aggregates are used in machine construction, raw material production, maritime and many other areas. In hydraulic systems oil transfers power and motion,
More informationSectional Directional Control Valve RSQ 240
Sectional Directional Control Valve RSQ 0 Key valve features RSQ 0 is a sectional open center valve, designed for max. operating pressures up to 50 bar and max. pump flows up to 00 l/min. It is available
More informationOil/air cooler BLK. Fluidcontrol
Fluidcontrol Oil/air cooler BLK Drives and hydraulic aggregates are used in machine construction, raw material production, maritime and many other areas. In hydraulic systems oil transfers power and motion,
More informationPlate Heat Exchangers
Plate Heat Exchangers General Plate heat exchangers are used wherever thermal energy (heat) has to be transferred from one fl uid to another. The advantage is that they can maintain the fl uid temperature
More informationSectional Directional Control Valve RS 220
Sectional Directional Control Valve RS 0 RS 0 is a sectional open center valve designed for max. operating pressures up to 00 bar and max. pump flows up to 0 l/min. Technical data Pressure and flow values*
More informationHydraulic Pump Series F1plus Fixed Displacement
Fixed Displacement Catalog 9129 8218-02 February 1999, GB Content General information, design 3 Specifications 4 Pump cross section 4 Pump and line selection 5 Ordering code 6 Standard versions 6 Installation
More informationFeed Pumps FZP / MFZP
eed Pumps ZP / MZP Symbol General The feed pump from the ZP series is a vane pump for the low-pressure range with constant flow rate. Product eatures l irect drive pump no bell housing or coupling required
More informationBYPASS SERIES GLOBAL STANDARD COOLER
BYPASS SERIES GLOBAL STANDARD COOLER OIL-to-AIR COOLING SYSTEMS WITH integrated Bypass and AC-MOTOR Product Information AKG-Line is a standard line of products from the market leader in high performance
More informationOil/air cooler BLK ATEX-3GD
FluidControl Oil/air cooler BLK ATEX-3GD Drives and hydraulic aggregates are also used in explosive areas in machine construction or raw material production. In hydraulic systems oil transfers power and
More informationCoolers. Air Cooled / Liquid Cooled
Air Cooled / Liquid Cooled HYDAC stands for worldwide presence and accessibility to the customer. HYDAC has over 1000 distributors worldwide and more than 40 wholly owned branches. Our know-how has evolved
More informationChange-Over Inline Filter AFLD to API 614
Change-Over Inline Filter to API 614 up to 17 l/min, up to 4 bar 112/ 113 122/ 123 232/ 233 242/243 332/333 52/53 542/543 882/883 142/143 272/273 1. TECHNICAL SPECIFICATIONS 1.1 FILTER HOUSING Construction
More informationE / HYDAC Control Cabinet Cooler HCC
HYDAC Control Cabinet Cooler HCC Machine tools Your Partner for Expertise in Cooling Systems. All the requirements... Located in the Bavarian town of Friedberg, H.I.B. is the centre of excellence for refrigeration
More informationup to size 381 up to PN 0.5 bar up to T = 80 C Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TSE
up to size 381 up to PN 0.5 bar up to T = 80 C Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TSE 1. DESCRIPTION 1.1. GENERAL HYDAC fluid level gauges FSA, fluid level sensors FSK
More informationCoolers. OK Series. Air Cooled Oil Coolers Hydraulic Symbol OK 1-11 OKF Cooling Systems Catalog. Applications
OK Series Air Cooled Oil Coolers Hydraulic Symbol OK 1-11 OKF 3-11 OKA 4-6 OKAF 4-6 OKA 8-11 OKAF 8-11 Description The OK Series cooler design uses a axial fan assembly which draws air through the cooler.
More informationIsolator Sandwich Plate
Isolator Sandwich late CEO Model code (also order example) KH4K DN10 CEO 5302 09 X Symbol DN 06 Designation KH4K = 4-gallery isolator ball valve KH6K = 6-gallery isolator ball valve Nominal bore DN06 DN10
More informationGLOBAL STANDARD COOLER
GLOBAL STANDARD COOLER A A OIL-to-AIR COOLING SYSTEMS WITH AC-MOTOR Product Information AKG-Line is a standard line of products from the market leader in high performance aluminium cooling systems. AKG
More informationReturn line and Suction Boost Filter RKM
Return line and Suction Boost Filter up to 850 l/min, up to 10 bar 80 100 120 151 201 251 201/-TH 300 350 400 800 1. TECHNICAL SPECIFICATIONS 1.1 FILTER HOUSING Construction The filter housings are designed
More informationVariable Vane Pump, Direct Controlled PV7...A Series 1X / 2X
Variable Vane Pump, Direct Controlled PV7...A Series 1X / X RE 1 Issue: 1.13 Replaces: 8.8 Sizes 1 to Maximum pressure 1 bar Displacement volume 1 to cm 3 Features Very short control times Low noise Mounting
More informationUD and UC Gear pump unit
1-19-EN for SKF CircOil or hydraulic lubrication systems General Information The UC and UD gear pump units are vertically or horizontally arranged units that are used in hydraulic or circulating-oil lubrication
More informationReturn Line Filter RFM with 4-Hole Mounting
Return Line Filter with 4-Hole Mounting Tank-top mounted versions: up to 850 l/min, up to 10 bar 75 90 150 165 185 210 270 330 500 600 661 851 1. TECHNiCAL SPECIFICATIONS 1.1 FILTER HOUSING Construction
More informationA20 A20. Aluminium heat exchanger 398SAE004EN00
Aluminium heat exchanger A A 98SAEEN Before using the heat exchanger, carefully read the document entitled GENERAL INSTRUCTIONS FOR HEAT EXCHANGER USE. 98SAEEN - --7 A V-V Dimensions ± L MAX C 8,, H ±
More informationGLOBAL STANDARD COOLER
COOLER H H OIL-To-AIR COOLING SYSTEMS WITH HYDRAULIC MOTOR Product Information AKG-Line is a standard line of products from the market leader in high performance aluminium cooling systems. AKG is best
More informationFA 016 FAPC 016. Oil Service Units. Description. Page 53
Oil Service Units FA 016 FAPC 016 Easy filling and cleaning Compact design, comfortable handling High filtration efficiency Option: with oil cleanliness monitor and data storage Description FA 016 With
More information2/2 way Coaxial valve CXRM compact, pilot operated Modular design
2/2 way Coaxial valve CXRM compact, pilot operated Modular design Model code (also example order) CXRM 2/2 F C 2 08 040 038 V Standard NC (closed when de-energised) With external 3/2-way pilot valve 4
More informationReturn Line Filter HF4R up to 450 l/min, up to 10 bar
Return Line Filter HF4R up to 450 l/min, up to 10 bar 9" 18" 27" 1. TECHNiCAL SPECIFICATIONS 1.1 FILTER HOUSING Construction The filter housings are designed in accordance with international regulations.
More informationGLOBAL STANDARD COOLER
GLOBL STNDRD COOLER GLOBL STNDRD OIL-TO-IR COOLING SYSTEMS WITH C-MOTOR PRODUCT INFORMTION KG CooL-Line is a standard line of products from the market leader in high performance aluminium cooling systems.
More informationGLOBAL STANDARD COOLER
GLOBAL STANDD COOLER AKG 2009 (changes and errors expected) GLOBAL STANDD Rugged Environment COOLING SYSTEMS Product Information AKG CooL-Line is a standard line of products from the market leader in high
More informationGLOBAL STANDARD COOLER
GLOBAL STANDD COOLER AKG 2009 (changes and errors expected) GLOBAL STANDD RUGGED ENVIRONMENT COOLING SYSTEMS PRODUCT INFORMATION AKG CooL-Line is a standard line of products from the market leader in high
More informationOFFLINE SERIES GLOBAL STANDARD COOLER
OFFLINE SERIES GLOBAL STANDARD COOLER OIL-TO-AIR COOLING SYSTEMS WITH AC-MOTOR AND PUMP Product information AKG-Line is a standard line of products from the market leader in high performance aluminium
More informationGLOBAL STANDARD COOLER
GLOBAL STANDARD COOLER D D MOBILE HYDRAULIC OIL-TO-AIR COOLING SYSTEMS Product Information AKG-Line is a standard line of products from the market leader in high performance aluminium cooling systems.
More informationAKG 2009 (changes and errors expected) GLOBAL STANDARD COOLER
AKG 2009 (changes and errors expected) GLOBAL STANAR COOLER GLOBAL STANAR OIL-TO-AIR COOLING SYSTEMS WITH C-MOTOR PROUCT INFORMATION AKG CooL-Line is a standard line of products from the market leader
More informationCooling Systems Air Cooled / Liquid Cooled
Cooling Systems Air Cooled / Liquid Cooled About HYDAC HYDAC stands for worldwide presence and accessibility to the customer. HYDAC has over 1000 distributors worldwide and more than 40+ wholly owned branches.
More informationGLOBAL STANDARD COOLER
COOLER RUGGED ENVIRONMENT COOLING SYSTEMS PRODUCT INFORMATION AKG CooL-Line is a standard line of products from the market leader in high performance aluminum cooling systems. AKG is best known for its
More informationA26. Aluminium heat exchanger A26
Aluminium heat exchanger A A Before using the heat exchanger, carefully read the document entitled GENERAL OPERATING INSTRUCTIONS FOR HEAT EXCHANGER USE 98SAEEN - 8--8 A V-V Dimensions ± L MAX 99 H ± T
More informationOff-line filter / cooler unit FGSL
Fluidcontrol Off-line filter / cooler unit FGSL Coolers are used to stabilise the operating temperature in hydraulic and lubrication systems. This can be implemented particularly cost-efficiently by integrating
More informationGLOBAL STANDARD COOLER
GLOBAL STANDD COOLER GLOBAL STANDD RUGGED ENVIRONMENT COOLING SYSTEMS PRODUCT INFORMATION AKG CooL-Line is a standard line of products from the market leader in high performance aluminium cooling systems.
More informationAKG A World Class Supplier. Your innovative partner to design and supply engineered cooling packages
LOCATION TELEPHONE FAX AKG Fellow Subsidiaries (Germany) Hofgeismar Autokühler GmbH & Co. KG +49 5 67-88 3- +49 5 67-35 82 Hofgeismar AKG Thermotechnik International +49 5 67-88 3- +49 5 67-35 82 GmbH
More informationElectrohydraulic Drive System EHC-A
Electrohydraulic Drive System EHC-A HYDAC Denmark HYDAC Poland HYDAC Brazil HYDAC India HYDAC China HYDAC USA HYDAC France HYDAC Germany Your Professional Partner for Electrohydraulic Drive Systems. With
More informationChange-Over Inline Filter RFLD Welded Version
Change-Over Inline Filter RFLD Welded Version up to 15000 l/min, up to 16 bar RFLD 1300 CAS to RFLD 15000 CBW 1. TECHNICAL SPECIFICATIONS 1.1 FILTER HOUSING Construction The filter housings are designed
More informationCooling Systems CC Series TT rail 20/30lpm
CC Series 20/30lpm General Data And Details The oil / air coolers of our CC series are autonomous cooling systems with an integrated circulation pump. They work as a separate cooling unit or as a ilter
More informationGLOBAL STANDARD COOLER
GLOBAL STANAR COOLER GLOBAL STANAR MOBILE HYRAULIC OIL-TO-AIR COOLING SYSTEMS Product Information AKG-Line is a standard line of products from the market leader in high performance aluminium cooling systems.
More informationPressure Filter for Manifold Mounting DFP and for Reversible Flow DFPF
Pressure Filter for Manifold Mounting DFP and for Reversible Flow DFPF up to 600 l/min, up to 315 bar 60 110 140 160 240 280 330 500 660 1.X 660 2.X 990 1320 1. TECHNiCAL SPECIFICATIONS 1.1 FILTER HOUSING
More informationAKG 2009 (changes and errors expected) GLOBAL STANDARD COOLER
KG 2009 (changes and errors expected) GLOBL STNDRD COOLER GLOBL STNDRD OIL-TO-IR COOLING SYSTEMS WITH C-MOTOR PRODUCT INFORMTION KG CooL-Line is a standard line of products from the market leader in high
More informationCompact hydraulic power unit Type BKA
Compact hydraulic power unit Type BKA Single- and two-stage up to 700 bar Features Compact design Self-venting Various combinations possible Single- or two-stage models Design Integrated low-pressure unloading
More informationHF box power packs. dc box power packs for mobile applications
HF box power packs dc box power packs for mobile applications HF box power pack series Hydraulfunktion has more than 20 year successfully manufactured and constantly improved box type dc power packs. HF
More informationRexroth Hydraulics. Fixed displacement vane pumps Types PVV and PVQ RE /11.97
RE 1 335/1.97 RE 1 335/11.97 Fixed displacement vane pumps Types and Nominal sizes 18 to 193 Series 1X Maximum operating pressure 21 bar Maximum displacement 18 to 193 cm 3 H/A/D 5769/97 Single pump type
More informationReturn Line Filter RFM with 4-Hole Mounting
Return Line Filter with 4-Hole Mounting Tank-top mounted versions: up to 850 l/min, up to 10 bar 75 90 150 165 185 195 210 270 330 500 600 661 851 1. TECHNICAL SPECIFICATIONS 1.1 FILTER HOUSING Construction
More informationGLOBAL STANDARD COOLER
COOLER OIL-To-AIR COOLING SYSTEMS WIT YDRAULIC MOTOR Product Information AKG CooL-Line is a standard line of products from the market leader in high performance aluminum cooling systems. AKG is best known
More informationGLOBAL STANDARD COOLER
COOLER OIL-To-AIR COOLING SYSTEMS WIT YDRAULIC MOTOR Product Information AKG-Line is a standard line of products from the market leader in high performance aluminium cooling systems. AKG is best known
More informationChange-Over Pressure Filter DFDK
Change-Over Pressure Filter up to 2500 l/min, up to 315 bar 30 60 110 140 160 240 280 330 500 660 1.x 660 2.x 990 2.x 1320 2.x 1320 3.x 2640 3.x 3960 3.x 1. TECHNiCAL SPECIFICATIONS 1.1 FILTER HOUSING
More informationMagHex Fan Controller
MagHex Fan ontroller 0916 ompact Programmable Temperature Sensor This combined sensor and controller is designed to mount directly to the heat exchanger. It provides accurate temperature control by cycling
More informationSpecification. Oil/Air- Cooling Systems AKG-Range T1 - T11. AKG A World Class Supplier
(T) Oil/Air- Cooling Systems AKG-Range T - T LOCATION AKG INTERNATIONAL TELEPHONE FAX AKG Fellow Subsidiaries (Germany) Hofgeismar Autokühler GmbH & Co. KG (49) 5 67-88 3- (49) 5 67-35 82 Hofgeismar AKG
More informationUM 045 UMPC 045 Oil service - simple, quick and compact with integrated particle monitor
Oil Service Units UM 045 UMPC 045 Oil service - simple, quick and compact with integrated particle monitor Easy filling, cleaning and pumping over Unbeatable ergonomics, comfortable handling High filtration
More informationGLOBAL STANDARD COOLER
GLOBAL STANDD COOLER AKG 009 (changes and errors expected) Sales@SouthwestThermal.com p. 888-6-8 f. 80-484-0049 www.akgcoolers.com GLOBAL STANDD Rugged Environment COOLING SYSTEMS Product Information AKG
More informationIPVP High-pressure Internal Gear Pumps for Variable Speed Drives
IPVP High-pressure Internal Gear Pumps for Variable Speed Drives Design and Function 7 6 5 9 2 5 6 7 8 2 9 4a 4b 3 Pinion shaft 2 Internal gear 3 Filler pin 4a Filler segment carrier 4b Filler sealing
More informationHydraulic pilot control units for armrest installation
Hydraulic pilot control units for armrest installation RE 64 555/04.06 /2 Replaces: 05.05 Type 4TH5, 4TH6, 4TH6N Series Contents Functional description, section, symbol 2 Technical data 3 Ordering details
More informationSelector Valve RV 713
Selector Valve RV 713 Key valve features RV 713 is a 3 way selector valve designed for flows up to 42gpm (160 Lpm) and max. operating pressures up to 3,625 psi (250 bar). Spools, both 2 and 3 position,
More informationHYDAC (Three-Phase Current) Compact Power Units CO1
HYDAC (Three-Phase Current) Compact Power Units CO1 Up to 250 bar Up to 20 l/min In accordance with EN 60034-1 suitable for: Short-term operation: S2 = 5 min* (average value) Intermittent operation: S3
More informationPressure Filter DF...K P, DF...M P, Flange Mounted
Pressure Filter, DF...M P, Flange Mounted up to 550 l/min, up to 260 bar DF...M P 330...1.X 160 240 280 500...1.X 660...1.X 660...2.X 990...2.X 1320...2.X 660...3.X 990...3.X 1320...3.X 1. TECHNICAL SPECIFICATIONS
More informationFeed Pumps Direct Drive Series 1.1.
1.1. FEED PUMP SERIES FZP AND MFZP 1. GENERAL The feed pump, type FZP, is a direct drive vane pump with constant flow rate. It is available with flanged motor (MFZP) and comes with internal pressure relief
More informationCooling Systems FLKS - 3S/1.0/W... FLKS - 3L/1.0/W DESCRIPTION
Cooling Systems FLKS - S/1.0/W... FLKS - L/1.0/W... 1. DESCRIPTION 1.1. APPLICATIONS Cooling circuits: Cooling of AC main drives Cooling of motor spindles on machining centres Cooling of transmission and
More informationBell Housings with Rigid / Flexible Pump Mounting PTS / PT
Bell Housings with Rigid / Flexible Pump Mounting PTS / PT 1. Description 1.1. General Bell housings are connection elements between drive motors and hydraulic pumps. Both connecting flanges are supplied
More informationOil/air coolers. Table of contents. Features. Possible applications. RE 50111/12.06 Replaces: Types KOL and KOLP
Oil/air coolers RE 50111/12.06 Replaces: 04.04 /24 Types KOL and KOLP Component series 1X aximum flow 400 l/min [105 GP] H7131 Table of contents Contents Page Features, possible applications 1 Description,
More informationHydraulic primary unit Type ABPAG
RE 51 018/11.02 Replaces: 07.96 Hydraulic primary unit Type PG Reservoir volumes 63 to 400 litres Maximum operating pressure 360 bar H 2375 Type PG.. Overview of contents Contents Page Features 1, 2 Ordering
More informationDiesel PreCare HDP up to 1800 l/h
Diesel PreCare HDP up to 1800 l/h Manual Fully automatic 1. TECHNICAL SPECIFICATIONS 1.1 FILTER The Diesel PreCare is an innovative system for diesel prefiltration which protects vehicle manufacturers
More informationA-L O C COOLING SYSTEM OLAER COOLERS. Olaer A-LOC with integrated circulation pump for industrial hydraulic systems
OLAER A-L O C COOLERS COOLING SYSTEM Olaer A-LOC with integrated circulation pump for Olaer A-LOC with integrated circulation pump for industrial hydraulic systems R OLAER A-LOC FOR OPTIMUM EFFICIENCY
More informationHydraulic Pump Series F1 Fixed Displacement
Fixed Displacement Catalog 9129 8201-02 August, 1997 GB Content General information 3 Specifications 4 Pump and line selection 5 Ordering code 5 Standard versions 5 Installation dimensions 6 Installation
More information3/2 Way Ball Valves KHB3K
/ Way Ball Valves KHBK Model code (also order example) KHBK G / L 0 X A... Designation KHBK = / way ball valve Type of connection G = Whitworth female thread ISO 8 LR = Pipe connection light range DIN
More informationInline Filter LPF D A Flange-Mounted up to 280 l/min, up to 25 bar
Inline Filter LPF D A Flange-Mounted up to 280 l/min, up to 25 bar 160 240 260 280 1. TECHNiCAL SPECIFICATIONS 1.1 FILTER HOUSING Construction The filter housings are designed in accordance with international
More informationCENTRIFLOW 3D WITH EC MOTOR >> Technical catalogue
CENTRIFLOW 3D Plug Fan WITH EC MOTOR >> Technical catalogue air comfort CentriFlow 3D 2 GMEC CentriFlow 3D - Technical Catalogue Contents GENERL Description and survey chart pplication... 3 General Survey
More information5.2 MEDIUM HEAVY DUTY SERIES SIZE 3
.2 MEDIUM HEAVY DUTY SERIES SIZE 3 CONTENTS PGI101 Ordering Code.2.1 Medium Heavy Duty Series Technical Information.2.2 Specifications.2.3 Hydraulic fluids.2.4 Viscosity range.2. Temperature range.2.6
More informationPressure Filter DF Pressure Filter for Reversible Oil Flow DFF/DFFX
Pressure Filter DF Pressure Filter for Reversible Oil Flow DFF/DFFX up to 2000 l/min, up to 420 bar DF/DFF...1.X/2.X 30 60 110 140 160 240 280 330 500 660 990 1320 1500 2000 3000 4000 DF...3.X DFFX...1.X/2.X
More informationMEDIUM PRESSURE FILTERS
Medium Pressure Filters 61-2999 psi Low-cost aluminum construction inline filters, provide flexibility for use in both mobile and industrial applications. Durable and light weight, these filters are ideal
More informationIGP /117 ED INTERNAL GEAR PUMPS SERIES 10 OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS HYDRAULIC SYMBOL
00/7 ED IGP INTERNAL GEAR PUMPS OPERATING PRINCIPLE IGP pumps are volumetric displacement pumps with internal gears, available in five sizes, each divided into a range of different displacement. The pumps
More informationInline filters NF NF 1350 NF 330 NF 750 NF 500 NF FILTER SPECIFICATIONS Nominal pressure
Inline filters up to 3500 l/min, up to 25 bar 160 240 280 330 500 750 950 1350 2650 on request 1310 2.x on request 2610 2.x 1340 2640 5240 7840 10440 1. TECHNICAL SPECIFICATIONS 1.1 FILTER HOUSING Construction
More informationRadial piston pump PR4 Series 1X
Radial piston pump R4 eries 1X RE 1160 Edition: 07.015 Replaces: 08.005 Fixed displacement izes 0,40 to,00 Maximum working pressure 700 bar Maximum displacement cm 3 R4-1X/1,00-450WA01M01 Features elf-priming,
More informationPUMP SIZE Flow rate at 1500 rpm lt/min Operating pressures bar
/7 ED VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES OPERATING PRINCIPLE The VPPL are variable displacement axial-piston pumps with variable swash plate, suitable for applications
More informationTemperature Sensors. How to Order Consult factory for pricing and lead time. Normally Open (Closed on temperature rise)
Temperature Sensors 0916 Normally Open (losed on temperature rise) ontact Rating 6 MPS T 120 V 4 MPS T 240 V Voltage 0.1 to 240 volts or 12 VD 8 MPS, 24 VD 4 MPS Pressure 1,000 PSI operating Material 303
More informationDCS- series. Classic
DCS- series Classic Classic standard models 80 HEAT REJECTION HP @ 100F ETD 70 60 50 40 30 20 10 0 DCS60 DCS45 DCS30 DCS20 DCS16 DCS10 0 10 20 30 40 50 60 70 80 90 OIL FLOW - GPM Specifications: Maximum
More informationA-L A C AIR OIL COOLER LUFT/ÖL-KÜHLER OLAER COOLERS. Olaer A-LAC with A.C. motors for industrial hydraulic systems
OLAER A-L A C COOLERS AIR OIL COOLER Olaer A-LAC with A.C. motors for industrial hydraulic systems Olaer A-LAC with A.C. motors for industrial hydraulic systems LUFT/ÖL-KÜHLER Oiltech LAC mit Wechselstrommotor
More informationAxial-flow Fan AFC. Model numbering system AF C / T. Accessories Three phase. Power rate 1.
xial-flow Fan FC Construction xial fan designed for installation in a ducted system. Casing of rolled and electro-welded steel sheet, powder coated RL5. Impeller in polypropylene. Casing in acid-proof
More informationCalculation of external available Pressure. 1. Criterion flow velocity (Ref. 20 C) Do not design units in conditions acc. to white areas!
Page 1 Standard Series Size: 3 Air flow volume Calculation of external available Pressure [m³/h] 3 4 5 55 6 65 7 75 8 9 1 11 12 1. Criterion flow velocity (Ref. 2 C) Do not design units in conditions acc.
More informationHeat exchanger AB-E oil / water system: single tube. 1 Area of application. 2 Model. Company standard. Replaces: Issue
Company standard oil / water system: single tube AB-E 32-09 2003-04-09 Replaces: Issue 1999-05-04 1 Area of application The coolers to this standard are suitable for cooling the following fluids: Mineral
More informationMobile Filter Unit MFU-15
Mobile Filter Unit MFU-15 Description The MFU 15 MobileFiltration unit is used as a portable service unit for filling hydraulic systems, flushing small hydraulic systems as well as for cleaning in bypass
More information5.1 MEDIUM HEAVY DUTY SERIES SIZE 2
.1 MEDIUM HEAVY DUTY SERIES SIZE 2 CONTENTS PGI100 Ordering Code.1.1 Medium Heavy Duty Series Technical Information.1.2 Specifications.1.3 Hydraulic fluids.1.4 Viscosity range.1. Temperature range.1.6
More information