A-L A C AIR OIL COOLER LUFT/ÖL-KÜHLER OLAER COOLERS. Olaer A-LAC with A.C. motors for industrial hydraulic systems
|
|
- Simon Osborne
- 1 years ago
- Views:
Transcription
1 OLAER A-L A C COOLERS AIR OIL COOLER Olaer A-LAC with A.C. motors for industrial hydraulic systems Olaer A-LAC with A.C. motors for industrial hydraulic systems LUFT/ÖL-KÜHLER Oiltech LAC mit Wechselstrommotor für industrielle Hydrauliksysteme R
2 AN AIR OIL COOLER FOR DURABLE STRENGTH The Olaer A-LAC oil cooler is supplied with a single phase or a three phase A.C. motor and is designed for use in industrial applications. All the components have been developed in our own laboratory to ensure optimum harmonic operation. With the Olaer A-LAC series, we can supply air oil coolers of Olaer s well-known high quality, at short notice. The Olaer A-LAC series of air oil coolers can be fitted with a thermo contact for oil temperature control. Cooler matrix with low pressure drop and high cooling capacity. High cooling capacity - low pressure drop The ideal cooler will provide long-lasting oil durability hence extended hydraulic system life, minimize internal potentials for leaks, prolong lubricating qualities and maintain hydraulic efficiency for the entire working cycle. Olaer A-LAC air oil coolers are easy to install, easy to handle and have extremely high performance and durable strength. Own laboratory A series of quiet, long-lasting coolers with high cooling capacity per unit of surface area and a low pressure drop is the result of extensive research, development and testing in our own laboratory. The components are carefully selected to ensure optimum performance.the unique cooler design provides an excellent cooling capacity with regard to cooler size. During the development of the Olaer A-LAC series, we also took the opportunity to develop coolers for small cooling requirements, for which we predict an increasing demand in, for instance, leakage circuits. Simple and user-friendly design The A-LAC air oil cooler design is simple and user-friendly and is easy to dismantle for cleaning. Olaer A-LAC coolers are highly resistant to material fatigue,caused by vibrations and pressure spikes. The Olaer Group is represented worldwide providing you with service wherever you are located.the company's long traditions, range of customers and foresighted development have given us a wide technical expertise, an advantage for you by ensuring that the cooler you buy for your application is always the correct cooler. Calculate your cooling requirement Olaer has developed a calculation program where, by entering your basic data, you can calculate your cooling requirement and select the correct cooler.the program is available on request from your local Olaer company. For more detailed information, see separate information sheet.
3 Different by-pass functions are available to protect against cold starts. Can be fitted with dust and/or stone guard A.C. motors, 0V single phase or 400V three phase. Olaer A-LAC coolers for all applications Industrial Transmissions Presses Bale presses Gas turbines CD presses Concrete tile presses Stone crushers Fibreboard presses Pipe benders Gear boxes Binding machines Nibbling machines Gear drives Lathes Milling machines Transmissions Multi-operation machines Injection moulders Paper machines Crushers Mills Bearing lubrication Lifts Rock-drilling equipment Water jet cutters Cranes Tempering furnaces Transformers Converters Timber mill machines Saw transport equipment Diesel oil cooling Simulators Test rigs Welding machines Offshore equipment Winches Cranes Diesel motors Consult your local Olaer company for: type applications system construction dimensioning extreme operational conditions
4 AIR OIL COOLER Olaer A-LAC with A.C. motor - Technical specification Olaer A-LAC with A.C. motor - Technical specification For selection of the ideal oil cooler, find out required cooling capacity oil flow oil temperature max air temperature or use our calculation program. A-LAC A-LAC 0 A-LAC 0 - A-LAC 112 0, 0, The cooling capacity curves are based upon inlet oil temperature and ambient temperature. Oil temperature 60 C and air temperature 20 C gives a temperature difference of 40 C. Multiply by kw/ C for total cooling capacity , 3,00 The cooling capacity curves are based upon inlet oil temperature and ambient temperature. Oil temperature 60 C and air temperature 20 C gives a temperature difference of 40 C. Multiply by kw/ C for total cooling capacity , , Cooling capacity (kw/ C) 0, 0,40 0,30 0,20 0, , 3-phase 007-2, 1-phase 007-4, 3-phase 007-4, 1-phase 004-2, 1+3-phase 003-2, 1-phase 002-2, 1-phase Cooling capacity (kw/ C) 2,00 1, 1,00 0, , , Oil flow (l/min) 0, Oil flow (l/min) Pressure drop at 30 cst (single-pass) 3,4 3,2 3,0 016, , 110 2,8 2,6 007, 011 2,4 Pressure drop (bar) 2,2 2,0 1,8 1,6 1,4 1, , , 078, 112 1,0 0,8 0,6 0,4 0,2 0, Oil flow (l/min)
5 General drawing 007-0= =77,5 3) 1) Air Dust and stone guard Oil 2) 2) Support for ) Oil outlet when a by-pass valve type T or a two pass is used 2) Dimension for A-LAC A-LAC 007 1phase = 10. Dimensions Type A-LAC phase A-LAC phase A-LAC phase A-LAC phase A-LAC phase A-LAC phase A-LAC phase A-LAC phase A-LAC phase A-LAC phase A-LAC phase A-LAC phase A-LAC phase A-LAC phase A-LAC phase A-LAC phase A-LAC phase A-LAC phase A-LAC phase A-LAC phase A-LAC phase A-LAC phase A-LAC phase A-LAC phase A-LAC phase A-LAC phase A-LAC phase A-LAC phase A-LAC phase A-LAC phase A-LAC phase A-LAC phase A-LAC phase A B C D E F G H I J K L M N O P Q 3) G 1 /2 1 /4 1 /4 1 /4 1 /4 1 /4 1 /4 1 /4 1 /2 1 / ) "Q" when a by-pass valve type S is selected.
6 Type Acoustic pressure level db(a) at 1 m* A-LAC phase A-LAC phase 61 A-LAC phase 63 A-LAC phase 63 A-LAC phase 65 A-LAC phase 7 A-LAC phase 64 A-LAC phase 7 A-LAC phase 6 A-LAC phase 83 A-LAC phase 63 A-LAC phase 73 A-LAC phase 86 A-LAC phase 66 A-LAC phase 77 A-LAC phase 74 A-LAC phase 84 A-LAC phase 76 A-LAC phase 85 A-LAC phase 73 A-LAC phase 81 A-LAC phase 84 A-LAC phase 74 A-LAC phase 82 A-LAC phase 85 A-LAC phase 7 A-LAC phase 86 A-LAC phase A-LAC phase 87 A-LAC phase 84 A-LAC phase 0 A-LAC phase 85 A-LAC phase 1 * Noise level tolerance ± 3 db(a) 3 Air flow m 3 /sec 0,06 0,10 0,15 0,15 0,24 0, 0,2 0,56 0,61 0, 0,58 0,6 1. 0,2 1, 1,52 2,41 1,8 2, 2,24 3,08 3,65 2,00 2,60 3,20 3,30 4, 3,00 4,10 5, 7, 5,20 7,00 No of poles/ Capacity kw 2-0,05 2-0,05 2-0,07 2-0,07 4-0,08 2-0,24 4-0, 2-0,55 4-0, 2-1,10 6-0,18 4-0,37 2-1,10 6-0,18 4-0,75 6-0,55 4-2,20 6-0,55 4-2,20 8-0,55 6-1, 4-2,20 8-0,55 6-1, 4-2,20 8-1,10 6-2,20 8-1,10 6-2,20 8-2,20 6-5, 8-2,20 6-5, Weight kg 4,2 5 6,5 6,5,
7 Ordering key for Olaer A-LAC air oil cooler. When ordering every item should be specified. A-LAC-XXX-X-X-XX-XXX-X-X Air oil cooler fitted with AC motor = A-LAC 2. Cooler size Number of poles, motor Two-pole = 2 Four-pole = 4 Six-pole = 6 Eight-pole = 8 4. Voltage and frequency Without motor = 0 Three phase 0/400V, Hz* = A Three phase 275/4V, 60Hz* = B Single phase 0V, /60Hz = C Three phase 0/400 Hz, 275/4V 60Hz** = D Three phase 0V, Hz = E Three phase 400/60V, Hz*** = F Motor for special voltage = X (specify in text en clair) * for A-LAC 0 to A-LAC 076/ ** for A-LAC 002 to A-LAC 0. *** for A-LAC 076/078-6 to A-LAC Cooler matrix Standard = 000 Two pass = T00 Built-in pressure controlled by-pass valve, single-pass 2 bar = S20 5 bar = S 8 bar = S Built-in pressure controlled by-pass valve, two-pass* 2 bar = T20 5 bar = T 8 bar = T Built-in temperature and pressure controlled by-pass valve, single-pass C, 2.2 bar = S 60 C, 2.2 bar = S26 C, 2.2 bar = S27 0 C, 2.2 bar = S2 Built-in temperature and pressure controlled by-pass valve, two-pass* C, 2.2 bar = T 60 C, 2.2 bar = T26 C, 2.2 bar = T27 0 C, 2.2 bar = T2 * not available for A-LAC A-LAC Thermo contact Without thermo contact = C = 40 C = 60 C = 60 C = C = 0 C = 0 7. Matrix guard Without guard = 0 Stone guard = S Dust guard = D Dust and stone guard = P 8. Standard /special Standard = 0 Special = Z Example: A-LAC-0-6-A--T20-D-0 When ordering a special cooler, specify product, components, performance, dimensions etc., in text en clair. Price and time of delivery available on request. For further information and latest modifications, please enter our web site To facilitate selection of the correct cooler, order Olaer's calculation programme. 4
8 Fluid compatibility Mineral oil HL/HLP to DIN Oil/water emulsion HFA, HFB to CETOP RP 77H Water glycol HFC to CETOP RP 77H Phosphate esther HFD-R to CETOP RP 77H Material Matrix Fan blades/hub Fan housing Fan guard Other parts Surface treatment Aluminium Glass fibre reinforced polypropylene/aluminium Steel Steel Steel Electrostatically powder coated Technical specification, matrix Maximum static working pressure 21 bar Dynamic working pressure bar. Tested according to ISO/DIS Limits of heat transfer ± 6 % Maximum oil inlet temperature 120ºC. Three-phase motor Three-phase asynchronous motor to IEC 34.1 and IEC 72 in accordance with DIN 57530/VDE Voltages: Hz V/3-415V and 60 Hz 4-276V/0-4V or Hz 3-415V/660-60V and 60 Hz 0-4V/ V Insulation Class F Rise of temperature Class B Protection standard IP55 Single-phase motor Nominal voltage 0V /60 Hz Insulation Class B Rise of temperature Class B Protection standard IP A-LAC 004 three-phase motor Nominal voltage 0/400V /60 Hz Insulation Class B Rise of temperature Class B Protection standard IP Cooling capacity curves The cooling capacity curves in this technical sheet are based upon tests according to EN 1048 and are made using oil type ISO VG 46 at 60 C. Consult your local Olaer company for use with oil temperatures > 120 C with oil viscosity > cst in ambients rich in particles in contaminated environments at high altitudes Piping diagram for Olaer A-LAC air oil cooler
9 Distributor Oil Solutions Phone Fax International Phone Fax PO Box 653 Castlemaine Australia 34
10 OLAER COOLERS THE COMPLETE PRODUCT RANGE OLAER A-LAC OLAER A-LDC OLAER A-LHC OLAER A-LOC An air oil cooler designed for industrial applications fitted with single-phase or three-phase motor. The components have been developed in our laboratory for optimum performance. Max. cooling capacity 130 kw at ETD 40 C. An air oil cooler ideal for mobile applications because of its compact design and light weight, fitted with a 12V or a 24V DC motor. During the development of the A-LDC series of air oil coolers we developed also coolers for small cooling requirements. Max. cooling capacity 30 kw at ETD 40 C. An air oil cooler fitted with a hydraulic motor for heavy duty applications with high cooling requirement. The Olaer A-LHC air oil coolers are designed for industrial as well as mobile applications. Max. cooling capacity 130 kw at ETD 40 C. An extremely reliable air oil cooling system consisting of a matrix, a fan and a pump. Fitted with one electric motor only, this cooling system is easy to install and at a very low cost. The Olaer A-LOC cooling system is supplied fit for installation in your system. Max. cooling capacity kw at ETD 40 C. R THE OLAER GROUP AROUND THE WORLD: AUSTRALIA Olaer FCH. Tel: AUSTRIA Olaer Austria GmbH. Tel: BELGIUM S.A. Olaer Benelux, Tel: CZECHIA Olaer CZ s.r.o. Tel: DENMARK Oiltech DK. Tel: FINLAND Oiltech Hydraulics OY. Tel: FRANCE Olaer Industries S.A. Tel: GERMANY Olaer Industries GmbH. Tel: GREAT BRITAIN FCH Ltd. Tel: INDIA FCH India. Tel: ITALY Olaer Italiana S.p.A. Tel: KOREA Hyundai Olaer Hydraulic Co. Tel: NETHERLANDS Olaer Nederland B.V. Tel: NORWAY Oiltech AS. Tel: POLAND Oiltech Polska. Tel: SCHWIZERLAND Olaer (Schweiz) AG. Tel: SOUTH AFRICA FCH c/o Rolton Products CC. Tel: SPAIN Olaer-Oiltech Iberica SAU. Tel: SWEDEN Oiltech AB. Tel: USA Oil Air Hydraulics Inc. Tel: Please note: Being a renowned manufacturer of cooling systems for hydraulics, Olaer is constantly seeking ways to improve the specification and design of its products and alterations take place continually. The products in this brochure may be updated, altered in any way or discontinued, without prior notice. A-LAC. B/E micce rylander byrå
IWAKI MAGNETIC DRIVE PUMPS MDM. Patent JAPAN / U.S.A. / TAIWAN / EU / CHINA
IWAKI MAGNETIC DRIVE PUMPS Patent JAPAN / U.S.A. / TAIWAN / EU / CHINA Magnetic drive process pump resistant to dry run damage The Series of Magnetic drive process pumps have wetted parts made of fluororesin.
IWAKI MAGNETIC DRIVE PUMPS MDM. Patent JAPAN / U.S.A. / TAIWAN / EU / CHINA
IWAKI MAGNETIC DRIVE PUMPS Patent JAPAN / U.S.A. / TAIWAN / EU / CHINA Magnetic drive process pump resistant to dry run damage The Series of Magnetic drive process pumps have wetted parts made of fluororesin.
Drive systems & electrical energy production for construction, local government structures, large infrastructure and industrial projects
09.2007 / a 4183 en - 03.2008 / b Drive systems & electrical energy production for construction, local government structures, large infrastructure and industrial projects www.leroy-somer.com Drive systems
Oil/Air Cooler Units. Standard series OK-P type. Test procedure certified following EN
COMPLETE OIL / AIR COOLER WITH AXIAL FAN FOR INDUSTRIAL APPLICATIONS. Application These high performance coolers with axial fans are suitable for hydraulic cooling applications. Typical applications include:
AKG A World Class Supplier. Your innovative partner to design and supply engineered cooling packages
LOCATION TELEPHONE FAX AKG Fellow Subsidiaries (Germany) Hofgeismar Autokühler GmbH & Co. KG +49 5 67-88 3- +49 5 67-35 82 Hofgeismar AKG Thermotechnik International +49 5 67-88 3- +49 5 67-35 82 GmbH
Oil/Air Cooler Units. Mobile series with DC motor OK-ELD Type. Test procedure certified following EN 1048
MOBILE OIL / AIR COOLERS NEW COMPACT DESIGN WITH DC ELECTRIC FANS AND HIGH COOLING PERFORMANCE Application These coolers are designed specifically for mobile hydraulic applications where high performance
replacement parts 6.1 General 6.2 Ordering
6.0 Replacement Parts 6.1 General Always provide the serial number of the unit on which the parts will be used. The serial number is stamped on the unit nameplate. 6.2 Ordering To ensure proper operation,
MDM. Magnetic drive pumps Magnetic drive process pump resistant to dry run damage. Magnetic drive pumps. series
MDM series Magnetic drive pumps Magnetic drive process pump resistant to dry run damage Magnetic drive pumps The MDM Series of Magnetic drive process pumps have wetted parts made of fluororesin. Patent
LKI LKI-HYD COOLING. Series. advanced quality customized designs made in europe. Oil/Air heat exchangers. Low noise level. High performance.
advanced quality customized designs made in europe Oil/Air heat exchangers Series LKI For industrial use LKI-HYD For mobile use OIL-AIR COOLING Low noise level High performance Low cost The cut-away perspective
ISO Interface. Large capacity. Light weight. Accommodates enclosure IP65. Solenoid Valve (with M Connector) Conforming to ISO
P-EX01-A Solenoid Valve (with M Connector) Conforming to ISO 1507-1, Large capacity EVS1-01 (Size: 01) EVS1-0 (Size: 0) Light weight Size 01 (-position): 0.6kg Size 0 (-position): 0.18kg Flow rate 1000L/min
DSE /117 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL SERIES 11 SUBPLATE MOUNTING ISO p max 350 bar Q max 40 l/min
83 2/117 ED DSE3 DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL SUBPLATE MOUNTING ISO 41-3 p max 3 bar Q max l/min MOUNTING SURFACE OPERATING PRINCIPLE ISO 41-3-2-- (CETOP 4.2-4-3-3). 33 3.2 21. 12.7.1.7
1410 Series & 4413 / 4423 Series Intrinsically Safe Solenoid Operated Directional Control Valves & Pilot Valves for Marine Applications
1410 Series & 4413 / 4423 Series Intrinsically Safe Solenoid Operated Directional Control Valves & Pilot Valves for Marine Applications Intrinsically safe solenoid operated pilot valve 1410 Series The
GLOBAL STANDARD COOLER
COOLER RUGGED ENVIRONMENT COOLING SYSTEMS PRODUCT INFORMATION AKG CooL-Line is a standard line of products from the market leader in high performance aluminum cooling systems. AKG is best known for its
Specification. Oil/Air- Cooling Systems AKG-Range T1 - T11. AKG A World Class Supplier
(T) Oil/Air- Cooling Systems AKG-Range T - T LOCATION AKG INTERNATIONAL TELEPHONE FAX AKG Fellow Subsidiaries (Germany) Hofgeismar Autokühler GmbH & Co. KG (49) 5 67-88 3- (49) 5 67-35 82 Hofgeismar AKG
Mobile Filtration Systems SMFS-P and SMFS-U
SMFS-P-015 SMFS-U-030 SMFS-U-DL-015-G SMFS-U-060 SMFS-U-110 SMFS-U-CM-110 Mobile Filtration Systems SMFS-P and SMFS-U Introduction 2 Introduction STAUFF Filtration Technology offers a complete range of
NGS. Dual-Magnet Float Switch. Pressure: up to 25 bar. Density: > 0.7 kg/dm 3. High switch capacity. Material: stainless steel 1.
Dual-Magnet Float Switch measuring monitoring analysing NGS Pressure: up to 5 bar O O Medium temperature: up to 50 C Density: > 0.7 kg/dm 3 High switch capacity O O Connection: square flange, DIN flange,
The SHK manual chain hoist
0.206 The SHK manual chain hoist The SHK and SHK+ manual chain hoist The SHK manual chain hoist features a wide spectrum of applications, independent of a power supply. The robust, compact construction
WANNER ENGINEERING INC
Industrial Pumps WANNER ENGINEERING INC Durability, performance and simplicity of design make Hydra-Cell pumps the optimum choice for the widest range of pump applications. When we say Simply Built to
Axial Piston Units for Use with HF Fluids
RE 90 223/11.99 Replaces: 09.90 Axial Piston Units for Use with HF Fluids For mineral oil based fluids for axial piston units, see data sheet RE 90220 For environmentally acceptable fluids for axial piston
Made UNDER high pressure
Made UNDER high pressure Made FOR high pressure THE CONTRINEX HIGH-PRESSURE-RESISTANT INDUCTIVE SENSOR SERIES Contrinex is a leading international high-tech sensor company with headquarters in Switzerland.
IWAKI MAGNETIC DRIVE PUMPS MDM. Patent JAPAN / U.S.A. / TAIWAN / EU / CHINA
IWAKI MAGNETIC DRIVE PUMPS Patent JAPAN / U.S.A. / TAIWAN / EU / CHINA Magnetic drive process pump resistant to dry run damage The Series of Magnetic drive process pumps have wetted parts made of fluororesin.
Single-acting pneumatic cylinder type ECS
Single-acting pneumatic cylinder type ECS Information is only for informational purpose. All specifications are subject to change without notice. 1 2015-06-18 issue: 2 Single-acting pneumatic cylinder
CAST RESIN DISTRIBUTION TRANSFORMERS 2016 EDITION
CAST RESIN DISTRIBUTION TRANSFORMERS 2016 EDITION TMC TRANSFORMERS - GLOBAL NETWORK UK & IRELAND SPAIN NORTH AMERICA & CANADA GERMANY SWITZERLAND BENELUX & AUSTRIA ITALY POLAND INDIA CENTRAL & SOUTH AMERICA
IWAKI MAGNETIC DRIVE PUMPS MDM. Patent & Pat.Pend. JAPAN / U.S.A. / EU / CHINA / TAIWAN
IWAKI MAGNETIC DRIVE PUMPS Patent & Pat.Pend. JAPAN / U.S.A. / EU / CHINA / TAIWAN Magnetic drive process pump resistant to dry run damage The Series of Magnetic drive process pumps have wetted parts made
DCS- series. Classic
DCS- series Classic Classic standard models 80 HEAT REJECTION HP @ 100F ETD 70 60 50 40 30 20 10 0 DCS60 DCS45 DCS30 DCS20 DCS16 DCS10 0 10 20 30 40 50 60 70 80 90 OIL FLOW - GPM Specifications: Maximum
No.1. Side approach mechanism Precise lateral contacting. Catalogue 1.1. Test Probes Test Fixtures
No.1 in testing solutions in der Prüftechnik Test Probes Test Fixtures Side approach Precise lateral contacting Catalogue 1.1 16 mm, 1 N contact force INGUN for precise lateral contacting -controlled operated
Feed Pumps VP / VPB / VPBM
Feed Pumps VP / VPB / VPBM Symbol General The feed pumps from the VP series are low-noise, single-stroke vane pumps with constant flow rate. Using a damped bell housing (PT) enables noise levels to be
M SERIES. Electric Motors
Electric otors Range They are the most effective and economical answer to needs of alternating current transmission. The threephase motors are available, in accordance with the IEC international standards,
Plate Heat Exchangers
Plate Heat Exchangers General Plate heat exchangers are used wherever thermal energy (heat) has to be transferred from one fl uid to another. The advantage is that they can maintain the fl uid temperature
Slide Bearings Type E For Shaft Diameter Range mm Main Application Field Electric Machines
Slide Bearings Type E For Shaft Diameter Range 160-315 mm Main Application Field Electric Machines End flange mounted slide bearing type EFWF with water-cooling and lubrication by a fixed oil ring RENK
Return Line Filter HF4R up to 450 l/min, up to 10 bar
Return Line Filter HF4R up to 450 l/min, up to 10 bar 9" 18" 27" 1. TECHNiCAL SPECIFICATIONS 1.1 FILTER HOUSING Construction The filter housings are designed in accordance with international regulations.
Circulation pumps BFP-ATEX-T3/T4
Circulation pumps BFP-ATEX-T3/T F ATEX - range of use: to zone 1 and zone 1 T3 to zone 1 and zone 1 T Low noise emission High vol. efficiency Optimum suction Gerotor principle Resistant to contamination
MT MODULAR MONITORING SYSTEM
MT MODULAR MONITORING SYSTEM MARTECHNIC AIMS AT: Enabling smooth operations like a well-oiled machine Monitoring continuously and efficiently Providing possibilities to extend the useful lifetime of oil
FSP Fan Speed Power Module Technical Data
PCN: 800 373 Q0337 Signal 0... 10V 230VAC 8A 230VAC 8A FSP Technical Data Electronic Power Modules FSP control the speed of condenser fan motors in commercial refrigeration and airconditioning systems.
Slide Bearings Type EM 9S For Shaft Diameters 80, 90, 100 mm Main Application Field Electric Machines
Slide Bearings Type EM 9S For Shaft Diameters 80, 90, 100 mm Main Application Field Electric Machines Centre flange mounted slide bearing type EM 9S The RENK EM 9S bearing is a fully self-contained, centre
Paddle Flow Monitor Model PSR/PSE
Paddle Flow Monitor for liquids measuring monitoring analysing PSR/PSE Switching ranges: 2.5-4.8... 383-533 p max : 250 bar, t max : 110 C Connection: G ¼... G 1 ½, ¼" NPT... 1 ½" NPT S3 : or stainless
Roller Dynamometer Performance and Function Tester for cars, trucks and motorcycles Model: LPS 3000
Roller Dynamometer Performance and Function Tester for cars, trucks and motorcycles Model: LPS 3000 Continuous measurement Discrete measurement Load simulation Elasticity measurement Speedometer test Graphics
Q max 300 l/min. Fluid temperature range C Fluid viscosity range cst Recommended viscosity cst 25
41 420/103 ED DSP7 PILOT OPERATED DISTRIBUTOR SOLENOID OR HYDRAULIC(DSC7) CONTROLLED SERIES 10 CETOP 07 p max (see performance ratings table) Q max 300 l/min MOUNTING INTERFACE CETOP 4.2-4-07-320 The DSP7
GEA charge air cooler. Innovations that put big things into motion. GEA Heat Exchangers GEA Maschinenkühltechnik
GEA charge air cooler Innovations that put big things into motion GEA Heat Exchangers GEA Maschinenkühltechnik Charge air cooler in general GEA Maschinenkühltechnik Established component developer For
Extraction arms for every type of application
1 Extraction arms for every type of application 2 Improved workspaces within arm s reach A workspace free from dust, hazardous particles, fumes and exhaust is good in many ways. It improves the working
Linear ActuAtors, Ball and Planetary
Linear ActuAtors, Ball and Planetary Roller Screws HIGH PERFORMANCE DESIGN INCREASES machine productivity WHAT MOVES YOUR WORLD high performance electric linear actuation With rising utility costs and
Flow. Oval Wheel Flowmeter Model DOE
Oval Wheel FIowmeter for low and high viscous liquids measuring monitoring analysing DOE Measuring range: 0.5 36 l/h und 1 40 l/min Viscosity range: 1 1000 cp Accuracy: ±1% of reading Material: stainless
High Flow Cartridge Valves 2/2 Way Series NG16 NG100
High Flow Cartridge Valves 2/2 Way Series NG1 NG100 Table of Contents Designation Symbol Page General Description and Operating Principle 3 Sectional View Types of Cones and Sleeves 4 Specifications and
Slimline Axial Flow Fans 80mm 92mm 119mm
80mm, 119mm Features: Low cost, low noise, high pressure fans. Sleeve bearings. Rated plastic impellers. Supplied with 300mm, 22AWG lead wire. 80mm, 92mm, 119mm Slimline Features: Low cost slimline AC
Air Cooled Exchangers With Aluminium Cooling Elements
AIR COOLED Versacool Series Cooler AC electric models deliver more air flow resulting in greater performance while using a smaller diameter lower noise fan. Cylindrical air jet discharge pattern eliminates
PRODUCT CATALOGUE CHILLER ECOMAX
PRODUCT CATALOGUE CHILLER ECOMAX English/02-2005 AIR COOLED CHILLER INTRODUCTION TO THE RANGE The simple and robust design of the Ecomax range brings real benefits in terms of savings in investment, operation
D6.. Butterfly valves. For controlled operation.
D6.. Butterfly valves. For controlled operation. Water is our element. www.belimo.eu Total solutions for medium and large volumetric flows. Butterfly valves from Belimo are available as classical D6..N
4/3, 4/2 proportional directional valves solenoid operated (for open loop control)
/, / proportional directional valves solenoid operated (for open loop control) RE -/7. Replaces: RE7/.7 / Type L (LCP) Size Series Maximum operating pressure bar [ psi] Nominal flow rated l/min [.7 gpm]
Change-Over Inline Filter RFLD Welded Version
Change-Over Inline Filter RFLD Welded Version up to 15000 l/min, up to 16 bar RFLD 1300 CAS to RFLD 15000 CBW 1. TECHNICAL SPECIFICATIONS 1.1 FILTER HOUSING Construction The filter housings are designed
giroflex 63 Stoll Giroflex AG
Reduced to the bare essentials but nonetheless special: the giroflex 63 has an appealing architectural style of design. Its architectural lines give the giroflex 63 an air of independence. The ergonomic
Photo courtesy of NZTA
international comparisons for road deaths Photo courtesy of NZTA 14 Motor Vehicle Crashes in New Zealand international comparisons for road deaths 141 Contents TABLES Table 1 International comparison of
4/3-4/2 Proportional directional valves L5080 solenoid (LC04P) operated (for open loop control) L5080 (LC04P)
/ - / Proportional directional valves L solenoid (LCP) operated (for open loop control) L (LCP) RE - Edition:. Replaces: 7. 7. Size Series Maximum operating pressure bar ( psi) Maximum flow l/min (.7 gpm)
Return line and Suction Boost Filter RKM
Return line and Suction Boost Filter up to 850 l/min, up to 10 bar 80 100 120 151 201 251 201/-TH 300 350 400 800 1. TECHNICAL SPECIFICATIONS 1.1 FILTER HOUSING Construction The filter housings are designed
AKG 2009 (changes and errors expected) GLOBAL STANDARD COOLER
KG 2009 (changes and errors expected) GLOBL STNDRD COOLER GLOBL STNDRD OIL-TO-IR COOLING SYSTEMS WITH C-MOTOR PRODUCT INFORMTION KG CooL-Line is a standard line of products from the market leader in high
MAINTENANCE OF SMOKE EXTRACTION MOTORS
4413 en - 2010.05 / b MAINTENANCE OF SMOKE EXTRACTION MOTORS Good practice guide Maintenance of smoke extraction motors Good practice guide The Maintenance or Repair of smoke extraction motors maintains
Pumps and Flow Measurement for the Polyurethanes Industry
Pumps and Flow Measurement for the Polyurethanes Industry 2 Pumps and flow measurement for the polyurethanes industry Content 3 Company 5 Gear Pumps for the Polyurethanes Industry 6 Pressure Relief Valves
testing to perfection MultiTest-i Technical Datasheet
testing to perfection MultiTest-i Technical Datasheet MultiTest 0.5-i, 1-i & 2.5-i 0.5 kn 1 kn 2.5 kn Height Width Depth Vertical Daylight* MultiTest 0.5-i 1710 mm (67.3) 290 mm (11.4) 414 mm (16.3) 1359
Product Overview INCH
INCH Product Overview CERTIFIED Technology Made in Italy Since 1955 the Varvel Group has been making gearboxes and variators for light industry applications. Reliable partner in power transmission equipment
Total credit to the non-financial sector (core debt), % of GDP Table F1.1
Total credit to the non-financial sector (core debt), % of GDP Table F1.1 2012 2013 2014 2015 2016 Q2 16 Q3 16 Q4 16 Q1 17 Q2 17 Argentina 62.6 66.4 64.6 75.5 75.3 81.7 80.1 75.3 71.6 72.7 Australia 208.0
Heat exchanger AB-E oil / water system: single tube. 1 Area of application. 2 Model. Company standard. Replaces: Issue
Company standard oil / water system: single tube AB-E 32-09 2003-04-09 Replaces: Issue 1999-05-04 1 Area of application The coolers to this standard are suitable for cooling the following fluids: Mineral
Test Probes Test Fixtures INGUN. Test Fixtures for low PCB volumes. Change made easy
Test Probes Test Fixtures INGUN Test Fixtures Change made easy MA 350/F with customized ATS MA350 force up to 300 N up to 160 x 100 mm MA 3xx-series generous and free accessibility MA 360/F with customized
Directional Control Valve Series D3W (Parker), 4D02 (Denison)
Characteristics Series D3W (Parker), 4D0 (Denison) The direct operated directional control valve size NG10 is available with both Parker (series D3W) and Denison (series 4D0) model codes. Both series are
INSTALLATION GUIDE NI 9921/9922 Outdoor IP Enclosure For NI WLS-9000 Series Devices
INSTALLATION GUIDE NI 99/99 Outdoor IP Enclosure For NI WLS-9000 Series Devices This guide describes how to install and use the National Instruments 99 and National Instruments 99 outdoor IP enclosures.
APV - load sensing VAlVe
APV - load sensing VAlVe APV16: APV 22: Max. flow : port A/B 120 l/min 330 l/min port A/B without compensator 140 l/min 380 l/min Max. pressure: port P/A/B 420 bar 420 bar Nominal pressure drop over 2-way
The Straight Way. Rectangular Cabinet Fan. Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans
Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans The Straight Way Rectangular Cabinet Fan Systemair India Pvt. Ltd. certifies that the Rectangular
D661-G...A Series Servovalve With Bushing and Integrated 24 Volt Electronics ISO 4401 Size 05
D661-G...A Series Servovalve With Bushing and Integrated 24 Volt Electronics ISO 4401 Size 05 OVERVIEW Section Page MOOG SERVO-PROPORTIONAL CONTROL VALVES Overview 2 3 Technical Data 4 5 Performance Specs.
S8V POWER SUPPLIES. High capacity in a compact format. » Long life switch mode power supplies. » performance and reliability
S8V POWER SUPPLIES High capacity in a compact format» performance and reliability» Long life switch mode power supplies» Complete single and 3 - phase ranges All the power to suit your needs... Our S8V
Axial Piston Fixed Motor A2FM
Axial Piston Fixed Motor A2FM RE 91001/06.2012 1/46 Replaces: 09.07 Data sheet Series 6 Size Nominal pressure/maximum pressure 5 315/350 bar 10 to 200 400/450 bar 250 to 1000 350/400 bar Open and closed
testing to perfection MultiTest-i Technical Datasheet
testing to perfection MultiTest-i Technical Datasheet MultiTest 0.5-i, 1-i & 2.5-i 0.5kN 1kN 2.5kN Height Width Depth Vertical Daylight* MultiTest 0.5-i 1710mm (67.3) 290mm (11.4) 414mm (16.3) 1359mm (53.5)
DEUTSCHE NORM March Hexagon head bolts Product grade C (ISO 4016 : 1999) English version of DIN EN ISO 4016
DEUTSCHE NORM March 2001 Hexagon head bolts Product grade C (ISO 4016 : 1999) English version of DIN EN ISO 4016 { EN ISO 4016 ICS 21.060.10 Sechskantschrauben mit Schaft Produktklasse C (ISO 4016 : 1999)
CTM magnetic drive centrifugal pumps rev 1
CTM magnetic drive centrifugal pumps 2012 rev 1 your reliable pumpchoice With experience from industrial fluid handling and pump manufacture since 1970, we know what you as a customer require from an industrial
Ultima SLM Ni-Cd battery Performance with ultra low maintenance
Ultima SLM Ni-Cd battery Performance with ultra low maintenance July 2004 2 Ultima Ni-Cd battery Ultra low maintenance Developed in line with long proven nickel-cadmium technology, Ultima is an exceptionally
Better sealing solutions for reciprocating compressors
Better sealing solutions for reciprocating compressors Experience and know-how the basis for innovation Rings and packings are critical components for the service life of reciprocating compressors. Therefore
Industrial Diesel Generator Set KD1750-UF 60 Hz Fuel Consumption Optimized
RATINGS 480 V - 60 Hz Standby kva 2187.50 KWe 1750 Prime kva 1989 KWe 1591 Benefits & features premium quality provides one source responsibility for the generating system and accessories The generator
Product Manual VIKING. EN397-3a 1999
Product Manual VIKING EN397-3a 1999 One partner all over the world Hägglunds Drives is one of the worlds leading manufacturer of heavy duty hydraulic drive systems. If what you need is low speed and high
Knife gate valve TV. Data is only for informational purpose. All specifications are subject to change without notice issue 9
Knife gate valve TV Data is only for informational purpose. All specifications are subject to change without notice. 1 2015-06-08 issue 9 Knife gate valve TV Stafsjö s knife gate valve TV can be used an
Industrial Diesel Generator Set KD1100-F 50 Hz Fuel Consumption Optimized
RATINGS 400 V - 50 Hz Standby kva 1100 KWe 880 Prime kva 1000 KWe 800 Benefits & features premium quality provides one source responsibility for the generating system and accessories The generator set,
TER. Thermostats for Industrial Applications. Switching range: C to C. Housing material: aluminium. Capillary tube: copper
Thermostats for Industrial Applications measuring monitoring analysing TER OO Switching range: - 20... + 30 C to 80... +130 C OO Housing material: aluminium OO Capillary tube: copper T1 Model: TER-TX490
Kawasaki Motors Corp., U.S.A. Precision Machinery Division HMB 100. Staffa Fixed Displacement Hydraulic Motor
Kawasaki Motors Corp., U.S.A. Precision Machinery Division HMB 100 Staffa Fixed Displacement Hydraulic Motor CONTENTS Page 1. General Description... 2 2. Functional Symbols... 2 3. Model Code... 3 4. Performance
Suction Filter SF/SFM/SFF and Suction Filter Elements S/S..
Suction Filter /M/F and Suction Filter Elements S/S.. up to 500 l/min Filters: 60 110 160 240 330 M 330 F 400 F 500 Elements: S SH. SU. SG. 1. TECHNICAL SPECIFICATIONS 1.1 FILTER HOUSING Construction The
DEUTSCHE NORM January Fasteners Electroplated coatings (ISO 4042 : 1999) English version of DIN EN ISO 4042
DEUTSCHE NORM January 2001 Fasteners Electroplated coatings (ISO 4042 : 1999) English version of DIN EN ISO 4042 { EN ISO 4042 ICS 21.060.01; 25.220.40 Verbindungselemente Galvanische Überzüge (ISO 4042
VPPM /110 ED VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS HYDRAULIC SYMBOL
16 100/110 ED VPPM VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS OPERATING PRINCIPLE The VPPM pumps are variable displacement axial-piston pumps with variable swash plate, suitable for applications with open
AUSTRIA. Table 1. FDI flows in the host economy, by geographical origin. (Millions of US dollars)
Table 1. FDI flows in the host economy, by geographical origin World 5 690 138 6 195 3 184 10 784 7 933 31 154 6 858 9 303 840 10 618 5 760 Developed economies 5 740 13 5 341 2 689 10 137 6 291 29 721
Stafsjö s ATEX solutions for category 1 D (Zone 20)
Stafsjö s ATEX solutions for category 1 D (Zone 20) Data is only for informational purpose. All specifications are subject to change without notice. 1 2017-02-2 issue 1 ATEX solutions for category 1 D
OUTSTANDING PERFORMANCE
ENGINEERED TO MOVE OUTSTANDING PERFORMANCE ON A GLOBAL SCALE We can demonstrate a proven ability to meet the needs of our customers and to support world leaders in their individual fields. It s not just
ADK Filter Drier. Alco Controls. Filter Drier. Features
ADK is a hermetic filter-drier with internal solid block for use on liquid line. Features Solid block Hermetic design Rugged steel shells Corrosion resistant epoxy paint Solder connection made from copper
Filter Elements. for use in HYDAC filters* Pressure filter. Pressure filter. filter element (DIN 24550) elements. long seam weld
1. TECHNiCAL SPECIFICATIONS 1.1 Construction As the core of the, it is the element which performs the actual filtration and/or dewatering function in the housing. They consist of several pleated filtration
Cooling Systems CC Series TT rail 20/30lpm
CC Series 20/30lpm General Data And Details The oil / air coolers of our CC series are autonomous cooling systems with an integrated circulation pump. They work as a separate cooling unit or as a ilter
giroflex 64 Stoll Giroflex AG
Over 1.5 million of the giroflex 64 have been sold worldwide. This kind of success is no coincidence this classic chair represents the unification of design and ergonomics at its highest level. The giroflex
MTC. Mold Temperature Control. Consilience Technology
We supply Take-out Robot, Factory Automation, Auxiliary Equipment, Auto Feeding system as an Integrated Engineering Solution provider. Consilience Technology MTC Mold Temperature Control 02 03 Company
Data sheet. Page: 1 / 5. ETL GGSAV11D BKSBIE3 Inline pump. Operating data. Design
Data sheet Page: 1 / 5 Operating data Requested flow rate Operating data determined for maximum inlet pressure Requested developed head 15.00 m Pumped medium Ambient air temperature 20.0 C Fluid temperature
Established leaders in Actuation Technology. ROM & RBM Range 1/4 turn direct drive electric actuators. Publication E611E issue 10/02
Established leaders in Actuation Technology ROM & RBM Range 1/4 turn direct drive electric actuators Publication E611E issue 10/02 Rotork Actuation Established Leaders in Actuation Technology As one of
Off-line filter / cooler unit BKF
FluidControl Off-line filter / cooler unit BKF In hydraulic systems oil transfers power and motion, and in drives it s a vital lubricant. Both as a power transfer medium and as a lubricant, oil is heated
LINE CONDITIONERS USER'S GUIDE
LINE CONDITIONERS USER'S GUIDE PE 1411/10 (9415 014 11 101) PE 1412/10 (9415 014 12 101) PE 1413/10 (9415 014 13 101) PE 1411/15 (9415 014 11 151) PE 1412/15 (9415 014 12 151) PE 1413/15 (9415 014 13 151)
Turbogenerators. With Top Performance for Steam and Gas Applications. Specifically tailored 4-pole Synchronous Turbogenerators
Turbogenerators With Top Performance for Steam and Gas Applications Specifically tailored 4-pole Synchronous Turbogenerators siemens.com / automation 2 Top Performance Turbogenerators for Steam and Gas
Durability, performance and simplicity of design make Hydra-CelfB pumps the optimum choice for the widest range of pum applications.
Durability, performance and simplicity of design make Hydra-CelfB pumps the optimum choice for the widest range of pum applications. When we say "Simply Built to Last", we mean it! Wanner Engineering Hydra-Cell
RME Thermal Management - Lubrication
RME Thermal Management - Lubrication Safety and performance... Ø 09, 12, 16, 20 and 25 mm Fluids coolant water, glycol water heat transfer oils lubricating oils esters gases Applications cooling of electronics
EDC DRY CLAW VACUUM PUMPS
edwardsvacuum.com EDC DRY CLAW VACUUM PUMPS INNOVATION AND RELIABILITY Edwards EDC range is a new generation of robust single stage dry claw vacuum pumps The new range of our EDC dry claw pumps features
Universal Charging and Testing Unit FPU-1 for Bladder, Piston and Diaphragm Accumulators
Universal Charging and Testing Unit FPU-1 for Bladder, Piston and Diaphragm Accumulators 1. Description 1.1. Function The HYDAC charging and testing unit FPU-1 is used to charge accumulators with nitrogen
SERIES SF2-500 SUCTION FILTER. Flow rates to 225 gpm
SERIES SF2-5 SUTION FILTER Flow rates to 225 gpm D e s c r i p t i o n 5 The SF2 series are designed for reservoir side-wall mounting applications, suitable for flow rates to 225 gpm and filtration from