1 Electrohydraulic Drive System EHC-A

2 HYDAC Denmark HYDAC Poland HYDAC Brazil HYDAC India HYDAC China HYDAC USA HYDAC France HYDAC Germany Your Professional Partner for Electrohydraulic Drive Systems. With over 8,000 employees worldwide, HYDAC is one of the leading suppliers of fluid technology, hydraulic and electronic equipment. Our wide range of products, combined with our expertise in development, manufacturing, sales and service enables the thermal power industry worldwide to overcome the most diverse challenges with the aid of electrohydraulic drive systems. Global yet local. With over 50 overseas subsidiaries and more than 500 sales and service partners, HYDAC is your reliable partner worldwide. System solutions. One supplier. One contact. Wherever you need us, we are there to help you find the most effective solution for almost every application, from components to a complete system. Worldwide specifications and approvals. 2

3 Electrohydraulic Drive System EHC-A Functional safety in the water/steam circuit Process technology systems in the power plant must be operated safely because they pose a considerable potential hazard to human health and the environment and can cause damage. When developing appropriate protection systems, the focus must centre on parts of the control which are relevant to the safety of the machine. This is particularly relevant for control valves and their drives which have an overlaid safety function. The requirement for a control valve with a safety function and the device for monitoring the steam condition are, amongst other things, described in EN ISO and TRD421. The objective of the regulations is to detect a failure safely and to trigger a safety function. Description and advantages By using electrohydraulic systems, movements can be controlled. Compared with other drive types, electrohydraulic drives are differentiated by: High power density Low moments of inertia High dynamic response Compact size High degree of accuracy High level of reliability and long life Integrated linear measurement Applications Water/steam circuit Minimum flow control valve Feed water flow control valve Level control valve Back-up steam control valve HD injection valve IS injection valve HP bypass station HP bypass station IS relief valve LP bypass station Condensate control valve Turbine shut-off valve Turbine inlet valve LP bypass station In the water/steam circuit, pressure and temperature are finely adjusted and controlled using steam valves to correspond with the requirements of the systems further downstream, for example the turbine. By using hydraulic actuators high quality control and the maximum dynamic response are achieved. 3 Note: The information in this brochure relates to the operating conditions and applications described. For applications or operating conditions not described, please contact the relevant technical department. Subject to technical modifications. Slam-shut valve to protect against turbine overspeed

4 Preferred ranges Electrohydraulic Drive System EHC-A Piston diameter D mm Rod diameter d mm Reduced piston diameter Dr mm Cylinder stroke max. hz mm Maximum pressure Pmax bar Working pressure min. Pa bar Static force from Working pressure min. FkOil (Pa) kn Spring force min. F1 kn Spring force max. F2 kn Counterforce from system (75 % of F1) FSteam kn Model code Electro Hydraulic Control Actuator Piston diameter XXX = mm Cylinder type S = Double rod cylinder (synchronizing) D = Single rod cylinder (differential) Type of spring D = Disc spring S = Spiral spring W = Without spring Direction of movementbwith spring assistance E = Extension R = Retraction EHC-A XXX X X X X Measurement technology W = Linear measurement system O = Optical/mechanical position indicator E = Limit switch P = Pressure measurement ( X ) = Redundant version possible 4

5 Technical Details Nominal pressure Operating fluids bar ISO VG 32, ISO VG 46, Mineral oil to DIN , HFD-U HFD-R fire-resistant ISO others on request Temperature range of environment -5 C to +60 C, option -20 C to +80 C Operating temperature optimum +40 to +50 C Atmosphere Relative humidity up to 90 % Electrical data Supply voltage Dusty industrial environment, potentially explosive according to ATEX Directive (optional) 24 V DC, 230 V 50/60 Hz AC Voltage tolerance up to +15 % / -15 % Nominal current of coil Protection class Nominal current for positioning module Target position % Actual position % Positioning 0.8 A for 24 V DC (TRD system), 1.2 A for 24 V DC (standard coil) IP65 (Standard), ExII 2G Eex d IIC T4 (Atex) < 100 ma 4-20 ma 4-20 ma Positioning accuracy < 1 % Repeatability < 0.1 % Hysteresis < 0.1 % Actuating times Control operation Controlled Open / Close Safety stroke Open / Close 3 s - 60 s 1 s - 30 s 0.1 s s 5

6 Function diagram Control module EHC-D Hydraulic control EHC-S Hydraulic cylinder EHC-A Item Control function Control adaption w Input scaling Feedback A B x Input scaling Enable Start Hand + Hand - Control program Ready InPos P T NG6 Option: Safety and Function Module The modular electrohydraulic safety controls EHC-S from HYDAC satisfy the requirements of IEC and IEC EHC-S 1oo1 Applications in so-called enable circuits EHC-M Function module for steam valve controls EHC-S 1oo3 For ball valve applications in water/steam circuits EHC-U Power unit for oil supply in turbine controls Other versions on request. EHC-S 2oo3 Applications in turbine controls and on process safety valves 6

7 System Expertise with First-Rate Service Network: Local Availability Worldwide. User accessories HYDAC offers a comprehensive and proven range of condition monitoring products, components and systems designed for fluid conditioning and monitoring as well as for technical cleanliness of components. Condition monitoring Contamination sensor CS 2000 To monitor the essential fluid parameters in turbine hydraulics online, HYDAC has developed an extensive fluid monitoring range which makes a significant contribution to the safe operation of both the turbine hydraulics and lubrication. FAM dewatering unit On lubrication oil systems of steam turbines, particularly high levels of unwelcome process steam and water enter the oil circuit. This results in substantially increased fluid ageing and limited lubrication. By using FAM dewatering and filtration units continuously during system operation, integrated conditioning of the lubrication media is assured. Degassing unit IXU When hydraulic fluids based on phosphate esters are used, it is essential to condition the fluids (also during system operation). HYDAC offers an extensive range of ionexchange conditioning products (IXU). NEW Stat-Free filter elements The operation of modern power plant hydraulics and lubrication systems with zinc-free fluids gives rise to risks of electrostatic charging of the oils (especially via the filter elements). Uncontrollable voltage flashovers, formation of sludge and varnish as well as rapid oil ageing are the result. HYDAC Stat-Free filter element technology prevents these unwelcome side-effects and increases the safety of the system for the operator. 7

8 Cooling Systems Electronics Accessories Compact Hydraulics Filter Systems Process Technology Filtration Technology Accumulator Technology Global Presence. Local Expertise. HYDAC Headquarters HYDAC Companies HYDAC Sales and Service Partners Head Office HYDAC SYSTEM GMBH Industriegebiet Sulzbach/Saar Germany Tel.: Fax: Internet:

HYDAC KineSys Motion Control Systems

HYDAC KineSys Motion Control Systems HYDAC KineSys Motion Control Systems Thermal power plants Materials handling Iron and steel industry Renewable energies Presses Plastic injection machines Your Partner for Expertise in Motion Control Solutions.

More information

Components and Systems for the Automotive Industry

Components and Systems for the Automotive Industry Components and Systems for the Automotive Industry E 10.136.0/03.12 HYDAC Germany HYDAC USA HYDAC China HYDAC Korea The Professional Partner for the Automotive Industry With over 6,000 staff worldwide,

More information

E / HYDAC KineSys Electric cylinders (HEZ)

E / HYDAC KineSys Electric cylinders (HEZ) E 10.146.1.1/02.15 HYDAC KineSys Electric cylinders (HEZ) NOTE The information in this brochure relates to the operating conditions and applications described. For applications or operating conditions

More information

Automatic Back-Flushing Filter for Process Technology AutoFilt RF3.

Automatic Back-Flushing Filter for Process Technology AutoFilt RF3. Automatic Back-Flushing Filter for Process Technology AutoFilt RF3. AutoFilt RF3: So automatic, The Challenge Particle contamination in process water and other operating fluids accelerates the rate of

More information

HYDAC Quality for Pall Housings: Ecomicron 2-fit.

HYDAC Quality for Pall Housings: Ecomicron 2-fit. HYDAC Quality for Pall Housings: Ecomicron 2-fit. Your Reliable Partner for Complete Fluid Management. HYDAC Experts for complete solutions. Numerous customers and applications are the proof of HYDAC s

More information

Proportional Pressure Reducing Valve PDM08130

Proportional Pressure Reducing Valve PDM08130 Proportional Pressure Reducing Valve PDM08130 up to 80 bar up to 10 l/min Cartridge valves Control electronics Connection housings 486 1. DESCRIPTION 1.1. GENERAL According to DIN-ISO 1219, HYDAC proportional

More information

2/2-Way Pressure Relief Valve CX DBV (Right-Angle Design)

2/2-Way Pressure Relief Valve CX DBV (Right-Angle Design) 2/2-Way Pressure Relief Valve CX DBV (Right-Angle Design) CX DBV-E Model code (also example order) CX DBV 12 120 G1 F P 24V Type CX DBV = Pressure relief valve Nominal size 10 = DN 10 12 = 15 = 20 = CX

More information

Pumps. Product Overview X.XXX.0/01.09 E /03.13 E /03.13

Pumps. Product Overview X.XXX.0/01.09 E /03.13 E /03.13 Pumps Product Overview 1 1. General Information 1.1 Operating Fluid Designation Standard Features Basic chemical composition Recommended seal material HL Improved anti-rust and antioxidant characteristics

More information

HYDAC KineSys The energy-efficient drive system

HYDAC KineSys The energy-efficient drive system HYDAC KineSys The energy-efficient drive system KineSys: The modern drive system from HYDAC Description: KineSys products and solutions are characterised by the perfect symbiosis of hydraulics and electromechanics.

More information

Automatic Back-Flushing Filter AutoFilt RF9.

Automatic Back-Flushing Filter AutoFilt RF9. Automatic Back-Flushing Filter AutoFilt RF9. AutoFilt RF9 Clearing the Way. The Challenge: In response to the Tier III standard which will come into effect in 2016, the International Maritime Organization

More information

E / Components, systems and service for telescopic loaders

E / Components, systems and service for telescopic loaders Components, systems and service for telescopic loaders HYDAC is one of the world's leading suppliers for fluid technology, hydraulics and electronics, employing over 8,000 people. With our wide range of

More information

Automatic back-flushing filter AutoFilt RF4

Automatic back-flushing filter AutoFilt RF4 Automatic back-flushing filter AutoFilt RF4 RF4-1 RF4-2 Specifications Nominal size: G1 G 1½ Q max: 220 l/min p max: 16 bar Filtration ratings: 30 1000 µm 1. GENERAL Product description Self-cleaning automatic

More information

E / EHCD Control modules for hydraulic transmissions.

E / EHCD Control modules for hydraulic transmissions. EHCD modules for hydraulic transmissions. Your professional partner for control technology. Global resence, Local Expertise. With over 8,000 employees worldwide, HYDAC is one of the leading suppliers for

More information

Change-Over Inline Filter AFLD to API 614

Change-Over Inline Filter AFLD to API 614 Change-Over Inline Filter to API 614 up to 17 l/min, up to 4 bar 112/ 113 122/ 123 232/ 233 242/243 332/333 52/53 542/543 882/883 142/143 272/273 1. TECHNICAL SPECIFICATIONS 1.1 FILTER HOUSING Construction

More information

Air Cooler Industry AC-LN 8-14 / ACA-LN 8-11 / ACAF-LN 8-11

Air Cooler Industry AC-LN 8-14 / ACA-LN 8-11 / ACAF-LN 8-11 Air Cooler Industry AC-LN 8-14 / ACA-LN 8-11 / ACAF-LN 8-11 Symbol General The AC-LN 8-14 air cooler series can be used in all areas where either oil or water-glycol is to be cooled with air. The coolers

More information

EN / Modern Duplex Filters for Large Engines

EN / Modern Duplex Filters for Large Engines Modern Duplex Filters for Large Engines Modern Duplex Filters for Diesel, HFO and Lube Oil Filtration has a key role to play in developing and optimising heavy engine technology. The quality of the fuel

More information

Change-Over Pressure Filter DFDK

Change-Over Pressure Filter DFDK Change-Over Pressure Filter up to 2500 l/min, up to 315 bar 30 60 110 140 160 240 280 330 500 660 1.x 660 2.x 990 2.x 1320 2.x 1320 3.x 2640 3.x 3960 3.x 1. TECHNiCAL SPECIFICATIONS 1.1 FILTER HOUSING

More information

Pressure Filter DF...K P, DF...M P, Flange Mounted

Pressure Filter DF...K P, DF...M P, Flange Mounted Pressure Filter, DF...M P, Flange Mounted up to 550 l/min, up to 260 bar DF...M P 330...1.X 160 240 280 500...1.X 660...1.X 660...2.X 990...2.X 1320...2.X 660...3.X 990...3.X 1320...3.X 1. TECHNICAL SPECIFICATIONS

More information

Filter Elements. for use in HYDAC filters* Pressure filter. Pressure filter. filter element (DIN 24550) elements. long seam weld

Filter Elements. for use in HYDAC filters* Pressure filter. Pressure filter. filter element (DIN 24550) elements. long seam weld 1. TECHNiCAL SPECIFICATIONS 1.1 Construction As the core of the, it is the element which performs the actual filtration and/or dewatering function in the housing. They consist of several pleated filtration

More information

D / Components, Systems and Service for tractors.

D / Components, Systems and Service for tractors. Components, Systems and Service for tractors. HYDAC Head Office Neuweiler HYDAC USA HYDAC India HYDAC China Your partner with expertise in tractors. HYDAC is one of the leading suppliers for fluid technology,

More information

Valve Technology and Special Solutions for Transmissions on Mobile Machines

Valve Technology and Special Solutions for Transmissions on Mobile Machines Valve Technology and Special Solutions for Transmissions on Mobile Machines Your partner for expertise in solutions specific to mobile transmissions Innovative and tailored valve solutions for modern mobile

More information

Change-Over Inline Filter RFLD Welded Version

Change-Over Inline Filter RFLD Welded Version Change-Over Inline Filter RFLD Welded Version up to 15000 l/min, up to 16 bar RFLD 1300 CAS to RFLD 15000 CBW 1. TECHNICAL SPECIFICATIONS 1.1 FILTER HOUSING Construction The filter housings are designed

More information

Pressure Filter for Manifold Mounting DFP and for Reversible Flow DFPF

Pressure Filter for Manifold Mounting DFP and for Reversible Flow DFPF Pressure Filter for Manifold Mounting DFP and for Reversible Flow DFPF up to 600 l/min, up to 315 bar 60 110 140 160 240 280 330 500 660 1.X 660 2.X 990 1320 1. TECHNiCAL SPECIFICATIONS 1.1 FILTER HOUSING

More information

Backflushing Filter AutoFilt RF4

Backflushing Filter AutoFilt RF4 1. Technical Specifications 1.1 General The automatic backflushing AutoFilt RF4 is a selfcleaning system for extracting particles from low viscosity fluids. Its robust construction and automatic backflushing

More information

Sectional Directional Control Valve RS 220

Sectional Directional Control Valve RS 220 Sectional Directional Control Valve RS 0 RS 0 is a sectional open center valve designed for max. operating pressures up to 00 bar and max. pump flows up to 0 l/min. Technical data Pressure and flow values*

More information

Sectional Directional Control Valve RSQ 240

Sectional Directional Control Valve RSQ 240 Sectional Directional Control Valve RSQ 0 Key valve features RSQ 0 is a sectional open center valve, designed for max. operating pressures up to 50 bar and max. pump flows up to 00 l/min. It is available

More information

Return Line Filter HF4R up to 450 l/min, up to 10 bar

Return Line Filter HF4R up to 450 l/min, up to 10 bar Return Line Filter HF4R up to 450 l/min, up to 10 bar 9" 18" 27" 1. TECHNiCAL SPECIFICATIONS 1.1 FILTER HOUSING Construction The filter housings are designed in accordance with international regulations.

More information

Phased Out Products. Proportional Valve Group PVG 83. Tech Note MAKING MODERN LIVING POSSIBLE

Phased Out Products. Proportional Valve Group PVG 83. Tech Note MAKING MODERN LIVING POSSIBLE MAKING MODERN LIVING POSSIBLE Tech Note Proportional Valve Group PVG 83 Valve system PVG 83 is a hydraulic load sensing valve designed to give the customer just the valve he needs. From a simple load sensing

More information

Price List 2018 Hire Equipment

Price List 2018 Hire Equipment Hire the equipment as you need it, instead of tying up capital unnecessarily. When equipment is only required for short periods, there is understandable opposition to making any costly investment. Hiring

More information

BYPASS SERIES GLOBAL STANDARD COOLER

BYPASS SERIES GLOBAL STANDARD COOLER BYPASS SERIES GLOBAL STANDARD COOLER OIL-to-AIR COOLING SYSTEMS WITH integrated Bypass and AC-MOTOR Product Information AKG-Line is a standard line of products from the market leader in high performance

More information

OLYMPUS. Gas Turbine Fuel Controls. Building of complete custom designed fuel systems. Single or serial production quantities

OLYMPUS. Gas Turbine Fuel Controls. Building of complete custom designed fuel systems. Single or serial production quantities OLYMPUS Gas Turbine Fuel Controls Gas Fuel Throttle Valve Liquid Fuel Throttle Valve Liquid Fuel Metering Pump Gas & Liquid Fuel Throttle Assemblies Building of complete custom designed fuel systems Single

More information

E / HYDAC Control Cabinet Cooler HCC

E / HYDAC Control Cabinet Cooler HCC HYDAC Control Cabinet Cooler HCC Machine tools Your Partner for Expertise in Cooling Systems. All the requirements... Located in the Bavarian town of Friedberg, H.I.B. is the centre of excellence for refrigeration

More information

Feed Pumps VP / VPB / VPBM

Feed Pumps VP / VPB / VPBM Feed Pumps VP / VPB / VPBM Symbol General The feed pumps from the VP series are low-noise, single-stroke vane pumps with constant flow rate. Using a damped bell housing (PT) enables noise levels to be

More information

Backflushing Filter AutoFilt RF3

Backflushing Filter AutoFilt RF3 Backflushing Filter AutoFilt C 2,5 4 6 8 1. TECHNICAL SPECIFICATIONS 1.1 GENERAL The automatic back-flushing filter AutoFilt is a self-cleaning system for extracting particles from lowviscosity fluids.

More information

OFFLINE SERIES GLOBAL STANDARD COOLER

OFFLINE SERIES GLOBAL STANDARD COOLER OFFLINE SERIES GLOBAL STANDARD COOLER OIL-TO-AIR COOLING SYSTEMS WITH AC-MOTOR AND PUMP Product information AKG-Line is a standard line of products from the market leader in high performance aluminium

More information

Price List 2013 In-House Repairs and Calibration

Price List 2013 In-House Repairs and Calibration In-House Repairs and Calibration Contents Page 2: Services Page 3: Repair and Certification Packages for Accumulators Page 4: Repair packages for Compact Hydraulics Power Units Page 5: Repair and Inspection

More information

GLOBAL STANDARD COOLER

GLOBAL STANDARD COOLER GLOBAL STANDD COOLER AKG 2009 (changes and errors expected) GLOBAL STANDD Rugged Environment COOLING SYSTEMS Product Information AKG CooL-Line is a standard line of products from the market leader in high

More information

GLOBAL STANDARD COOLER

GLOBAL STANDARD COOLER GLOBAL STANDD COOLER AKG 2009 (changes and errors expected) GLOBAL STANDD RUGGED ENVIRONMENT COOLING SYSTEMS PRODUCT INFORMATION AKG CooL-Line is a standard line of products from the market leader in high

More information

PLEIGER MASCHINENBAU. Valve Actuation, Controls and Automation

PLEIGER MASCHINENBAU. Valve Actuation, Controls and Automation Valve Actuation, Controls and Automation PLEIGER MASCHINENBAU -Hydraulic & Electro-Hydraulic Actuators -Linear & Rotary Actuators -Pleiger Controls and Automation -Hydraulic Power Units -Control Valves

More information

Process Inline Filter PLF1

Process Inline Filter PLF1 Process Inline Filter PLF1 10 bar 16 bar Specifications Nominal size: DN 50 DN 150 Q s max: 200 m 3 /h p s max: 16 bar Filtration ratings: 1 90 µm 1. GENERAL Product description Continuous separation of

More information

Pressure Filter DF Pressure Filter for Reversible Oil Flow DFF/DFFX

Pressure Filter DF Pressure Filter for Reversible Oil Flow DFF/DFFX Pressure Filter DF Pressure Filter for Reversible Oil Flow DFF/DFFX up to 2000 l/min, up to 420 bar DF/DFF...1.X/2.X 30 60 110 140 160 240 280 330 500 660 990 1320 1500 2000 3000 4000 DF...3.X DFFX...1.X/2.X

More information

Monoblock Directional Control Valve RM 230

Monoblock Directional Control Valve RM 230 Monoblock Directional Control Valve RM 230 Key valve features RM 230 light is a monoblock valve, designed for max. operating pressures up to 3,000 psi (210 bar) and typ. pump flows up to 20 gpm (70 Lpm).

More information

Return Line Filter RF

Return Line Filter RF Return Line Filter up to 15000 l/min, up to 25 bar 30 60 110 160 240 330 450 580 660 950 1300 2500 4000 5200 6500-7800 15000 1. TECHNiCAL SPECIFICATIONS 1.1 FILTER HOUSING Construction The filter housings

More information

GLOBAL STANDARD COOLER

GLOBAL STANDARD COOLER GLOBAL STANDARD COOLER A A OIL-to-AIR COOLING SYSTEMS WITH AC-MOTOR Product Information AKG-Line is a standard line of products from the market leader in high performance aluminium cooling systems. AKG

More information

P r e s s u r e i S w i t c h e s V a c u u m i S w i t c h e s PressureiTransmitters

P r e s s u r e i S w i t c h e s V a c u u m i S w i t c h e s PressureiTransmitters P r e s s u r e i M o n i t o r i n g P r e s s u r e i S w i t c h e s V a c u u m i S w i t c h e s PressureiTransmitters TRADITION AND INNOVATION From a mechanical workshop to an international industrial

More information

Return line and Suction Boost Filter RKM

Return line and Suction Boost Filter RKM Return line and Suction Boost Filter up to 850 l/min, up to 10 bar 80 100 120 151 201 251 201/-TH 300 350 400 800 1. TECHNICAL SPECIFICATIONS 1.1 FILTER HOUSING Construction The filter housings are designed

More information

Price List 2018 In-House Repairs and Calibrations

Price List 2018 In-House Repairs and Calibrations In-House Repairs and Calibrations Contents Page 2: Services Page 3: Repair and Certification Packages for Accumulators Page 4: Repair Packages for Compact Hydraulics Power Units Page 5: Repair and Inspection

More information

Filter module AF Features. MAHLE Industrialfiltration is now Filtration Group. For more information, visit

Filter module AF Features. MAHLE Industrialfiltration is now Filtration Group. For more information, visit MAHLE Industrialfiltration is now Filtration Group. For more information, visit www.filtrationgroup.com Filter module AF 43 Nominal pressure 16 bar, nominal temperature 180 C; nominal width DN 80 to DN

More information

Conditioning Module Reservoir Extraction CM-RE

Conditioning Module Reservoir Extraction CM-RE Conditioning Module Reservoir Extraction CM-RE Description The ConditioningModule Reservoir Extraction CM-RE is designed as an accessory to the CS ContaminationSensors and the FCU FluidControl Units. The

More information

Piston Accumulators High pressure

Piston Accumulators High pressure Piston Accumulators High pressure 1. DESCRIPTION 1.1. FUNCTION Fluids are practically incompressible and cannot therefore store pressure energy. The compressibility of a gas is utilised in hydraulic accumulators

More information

Selector Valve RV 713

Selector Valve RV 713 Selector Valve RV 713 Key valve features RV 713 is a 3 way selector valve designed for flows up to 42gpm (160 Lpm) and max. operating pressures up to 3,625 psi (250 bar). Spools, both 2 and 3 position,

More information

Plate Heat Exchangers

Plate Heat Exchangers Plate Heat Exchangers General Plate heat exchangers are used wherever thermal energy (heat) has to be transferred from one fl uid to another. The advantage is that they can maintain the fl uid temperature

More information

A-L A C AIR OIL COOLER LUFT/ÖL-KÜHLER OLAER COOLERS. Olaer A-LAC with A.C. motors for industrial hydraulic systems

A-L A C AIR OIL COOLER LUFT/ÖL-KÜHLER OLAER COOLERS. Olaer A-LAC with A.C. motors for industrial hydraulic systems OLAER A-L A C COOLERS AIR OIL COOLER Olaer A-LAC with A.C. motors for industrial hydraulic systems Olaer A-LAC with A.C. motors for industrial hydraulic systems LUFT/ÖL-KÜHLER Oiltech LAC mit Wechselstrommotor

More information

Turbogenerators. With Top Performance for Steam and Gas Applications. Specifically tailored 4-pole Synchronous Turbogenerators

Turbogenerators. With Top Performance for Steam and Gas Applications. Specifically tailored 4-pole Synchronous Turbogenerators Turbogenerators With Top Performance for Steam and Gas Applications Specifically tailored 4-pole Synchronous Turbogenerators siemens.com / automation 2 Top Performance Turbogenerators for Steam and Gas

More information

Replacement Elements

Replacement Elements Pressure Elements Used in OFS Series, OFCS & OFCD Series, OFAS & OFAD Series, OF5HS & OF5HD Series, and OFX Skid - Standard Capacity Series 9 inch Elements 18 inch Elements 27 inch Elements Part No. Part

More information

Servo solenoid valves with on-board electronics (OBE)

Servo solenoid valves with on-board electronics (OBE) Servo solenoid valves with on-board electronics (OBE) RE 29088/01.05 1/18 Replaces: 05.04 Type 4WRLE10...35, symbols V/V1 Size 10, 16, 25, 35 Unit series 3X Maximum working pressure P, A, B 350 bar, T,

More information

Return Line Filter RFM with 4-Hole Mounting

Return Line Filter RFM with 4-Hole Mounting Return Line Filter with 4-Hole Mounting Tank-top mounted versions: up to 850 l/min, up to 10 bar 75 90 150 165 185 210 270 330 500 600 661 851 1. TECHNiCAL SPECIFICATIONS 1.1 FILTER HOUSING Construction

More information

Return Line Filter RFM with 2-Hole Mounting

Return Line Filter RFM with 2-Hole Mounting Return Line Filter RFM with 2-Hole Mounting Tank-top versions: up to 200 l/min, up to 10 bar RFM 75 RFM 90 RFM 150 RFM 165 RFM 185 In-tank versions: up to 2,600 l/min, up to 10 bar RFM S RFM KIT RFM SET

More information

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor DMP Industrial Pressure Transmitter For High Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO Nominal pressure from 0... 00 bar up to 0... 600

More information

Air Cooler Mobile AC-LNH 8-14 with hydraulic motor

Air Cooler Mobile AC-LNH 8-14 with hydraulic motor ir Cooler Mobile C-LNH 8-1 with hydraulic motor Symbol General The C-LNH air cooler series is designed specifically for mobile hydraulic systems where high performance and efficiency are required and physical

More information

3/2 Way Ball Valves KHB3K

3/2 Way Ball Valves KHB3K / Way Ball Valves KHBK Model code (also order example) KHBK G / L 0 X A... Designation KHBK = / way ball valve Type of connection G = Whitworth female thread ISO 8 LR = Pipe connection light range DIN

More information

Suction Filter SF/SFM/SFF and Suction Filter Elements S/S..

Suction Filter SF/SFM/SFF and Suction Filter Elements S/S.. Suction Filter /M/F and Suction Filter Elements S/S.. up to 500 l/min Filters: 60 110 160 240 330 M 330 F 400 F 500 Elements: S SH. SU. SG. 1. TECHNICAL SPECIFICATIONS 1.1 FILTER HOUSING Construction The

More information

Inline Filter LPF D A Flange-Mounted up to 280 l/min, up to 25 bar

Inline Filter LPF D A Flange-Mounted up to 280 l/min, up to 25 bar Inline Filter LPF D A Flange-Mounted up to 280 l/min, up to 25 bar 160 240 260 280 1. TECHNiCAL SPECIFICATIONS 1.1 FILTER HOUSING Construction The filter housings are designed in accordance with international

More information

Inline filters NF NF 1350 NF 330 NF 750 NF 500 NF FILTER SPECIFICATIONS Nominal pressure

Inline filters NF NF 1350 NF 330 NF 750 NF 500 NF FILTER SPECIFICATIONS Nominal pressure Inline filters up to 3500 l/min, up to 25 bar 160 240 280 330 500 750 950 1350 2650 on request 1310 2.x on request 2610 2.x 1340 2640 5240 7840 10440 1. TECHNICAL SPECIFICATIONS 1.1 FILTER HOUSING Construction

More information

Filters. DFFH & DFFHM Series Service and Parts. Index. This symbol is followed by user tips and particularly useful information

Filters. DFFH & DFFHM Series Service and Parts. Index. This symbol is followed by user tips and particularly useful information 142.9 INLET 1.38 35 OUTLET Index 1.25 31.8 1. General 1.4 Tools Required for Maintenance 1.5 Torque Requirements 2. Maintenance 3. Changing the Element 4. Spare Parts List 5. Replacement Element Model

More information

Piston Accumulators High pressure

Piston Accumulators High pressure Piston Accumulators High pressure 1. DESCRIPTION 1.1. FUNCTION Fluids are practically incompressible and cannot therefore store pressure energy. The compressibility of a gas is utilised in hydraulic accumulators

More information

High Pressure Bypass System Type SOV acc. to TRD 421

High Pressure Bypass System Type SOV acc. to TRD 421 High Pressure Bypass System Type SOV acc. to TRD 421 GS valve engineering GmbH Phone: +49-208-833 2090 sales@gs-valve.eu Duisburger Strasse 375 Fax: +49-208-833-2095 www.gs-valve.eu 46049 Oberhausen GERMANY

More information

GLOBAL STANDARD COOLER

GLOBAL STANDARD COOLER COOLER RUGGED ENVIRONMENT COOLING SYSTEMS PRODUCT INFORMATION AKG CooL-Line is a standard line of products from the market leader in high performance aluminum cooling systems. AKG is best known for its

More information

Filters. HF3P Series Places 60 b c x d DP 4 Places Flange

Filters. HF3P Series Places 60 b c x d DP 4 Places Flange 1/2"-20UNF x 17 2.36 4 Places 60 b 6.42 163 5.23 133 4.53 115 c x d DP 4 Places a 6.30 Filters 160 6.42 163 Flange 2.05 0.24 52 6 P Clogging HF3P Series Indicator Port G 1/2" Service and Parts 6.30 160

More information

Proportional directional control valve, pilot operated with on-board electronics (OBE) and inductive position transducer

Proportional directional control valve, pilot operated with on-board electronics (OBE) and inductive position transducer Proportional directional control valve, pilot operated with on-board electronics (OBE) and inductive position transducer RE 29076/12.05 1/24 Type 4WRBKE Nominal size (NG) 10, 16, 27, 35 Unit series 1X

More information

Suction Filter SF/SFM/SFF and Suction Filter Elements S and S..

Suction Filter SF/SFM/SFF and Suction Filter Elements S and S.. Suction Filter /M/F and Suction Filter Elements S and S.. up to 500 l/min Filters: 60 100 160 240 330 M 330 F 400 F 500 Elements: S SH. SU. SG. 1. TECHNICAL SPECIFICATIONS 1.1 FILTER HOUSING Construction

More information

Process Inline Filter Protective filter PLF2-9HF

Process Inline Filter Protective filter PLF2-9HF Process Inline Filter Protective filter PLF2-9HF Specifications Nominal size: DN 300 - DN 600 Q s max: 3000 m 3 /h p s max: 16 bar Filtration ratings: 1-90 µm 1. GENERAL Product description Protective

More information

INSTRUCTION MANUAL. I/P Converter DSG BXXY3Z DSG BXXY4Z

INSTRUCTION MANUAL. I/P Converter DSG BXXY3Z DSG BXXY4Z INSTRUCTION MANUAL I/P Converter DSG BXXY3Z DSG BXXY4Z Revision 2.0 3.626 016136 en Page 1/15 Should you have any questions concerning the I/P converter, please contact the Service Department of the Product

More information

Expertise. Hydraulics. What you should know about us. excellent pressure solutions

Expertise. Hydraulics. What you should know about us. excellent pressure solutions Expertise Hydraulics What you should know about us excellent pressure solutions Welcome to Roth Hydraulics We develop and produce custom designed products and systems for fluid technology. Our core products

More information

Rotor locks. Hydraulic Electromechanical Modular design... all from one single supplier

Rotor locks. Hydraulic Electromechanical Modular design... all from one single supplier Rotor locks Hydraulic Electromechanical Modular design... all from one single supplier Modular rotor locks for on- and offshore wind turbines We accept every challenge and provide locking systems to suit

More information

Oil/air cooler BLK ATEX-3GD

Oil/air cooler BLK ATEX-3GD FluidControl Oil/air cooler BLK ATEX-3GD Drives and hydraulic aggregates are also used in explosive areas in machine construction or raw material production. In hydraulic systems oil transfers power and

More information

Winding technology, pneumatically actuated tension brakes web tension open-loop and feedback control systems

Winding technology, pneumatically actuated tension brakes web tension open-loop and feedback control systems Winding technology, pneumatically actuated tension brakes web tension open-loop and feedback control systems Ortlinghaus Plates. Clutches. Brakes. Systems. 왎 Winding technology - pneumatically actuated

More information

VariStroke I Electro hydraulic Actuator

VariStroke I Electro hydraulic Actuator Product Specification 03397 (Revision D, 5/2013) Applications VariStroke I Electro hydraulic Actuator The VariStroke-I is a linear electrohydraulic actuator that is designed to provide the linear actuation

More information

GLOBAL STANDARD COOLER

GLOBAL STANDARD COOLER GLOBAL STANDARD COOLER D D MOBILE HYDRAULIC OIL-TO-AIR COOLING SYSTEMS Product Information AKG-Line is a standard line of products from the market leader in high performance aluminium cooling systems.

More information

VariStroke II Electro hydraulic Actuator

VariStroke II Electro hydraulic Actuator Product Specification 03378 (Revision B, 9/2013) Applications VariStroke II Electro hydraulic Actuator The VariStroke-II is a linear electro-hydraulic actuator that is designed to provide the linear actuation

More information

2/2 way Coaxial valve CXRM compact, pilot operated Modular design

2/2 way Coaxial valve CXRM compact, pilot operated Modular design 2/2 way Coaxial valve CXRM compact, pilot operated Modular design Model code (also example order) CXRM 2/2 F C 2 08 040 038 V Standard NC (closed when de-energised) With external 3/2-way pilot valve 4

More information

Return Line Filter RF

Return Line Filter RF HYDAC return line filters type RF are designed to be mounted directly on tank tops. Inline mounting is also possible. Return Line Filter RF Flow rates up to 5, l/min Pressure range up to 25 bar Material:

More information

Inline Filters NF. Flow rates up to 3,500 l/min Pressure range 25 bar Material: Aluminium / Aluminium-Cast Iron

Inline Filters NF. Flow rates up to 3,500 l/min Pressure range 25 bar Material: Aluminium / Aluminium-Cast Iron NF filters are designed for inline mounting and as tank-top mounted return line filters. These filters can also be used on filling, flushing and off-line units. Inline Filters NF Flow rates up to 3,500

More information

D661-G...A Series Servovalve With Bushing and Integrated 24 Volt Electronics ISO 4401 Size 05

D661-G...A Series Servovalve With Bushing and Integrated 24 Volt Electronics ISO 4401 Size 05 D661-G...A Series Servovalve With Bushing and Integrated 24 Volt Electronics ISO 4401 Size 05 OVERVIEW Section Page MOOG SERVO-PROPORTIONAL CONTROL VALVES Overview 2 3 Technical Data 4 5 Performance Specs.

More information

BSM Series Pneumatic & Hydraulic Actuator Systems for Valves and Dampers

BSM Series Pneumatic & Hydraulic Actuator Systems for Valves and Dampers BSM Series Pneumatic & Hydraulic Actuator Systems for Valves and Dampers WORLDWIDE AUTOMATION SOLUTIONS The Fast-Track Manufacturer for Actuators & Controls Introduction BSM Actuators & Controls BSM Actuators

More information

Proportional pressure reducing valve, pilot operated, with on-board electronics (OBE) and position feedback

Proportional pressure reducing valve, pilot operated, with on-board electronics (OBE) and position feedback Proportional pressure reducing valve, pilot operated, with on-board electronics (OBE) and position feedback Type DREBE6X Nominal size (NG) 6 Unit series 1X Maximum working pressure P 315 bar, T 250 bar

More information

3-way servo solenoid valves, cartridge type, pilot operated, with inductive position transducer

3-way servo solenoid valves, cartridge type, pilot operated, with inductive position transducer 3-way servo solenoid valves, cartridge type, pilot operated, with inductive position transducer Type 3WRCB 25...50 Nominal size (NG) 25, 32, 50 Unit series 1X Maximum working pressure P, A, T, X, Z 315

More information

Servo solenoid valves with on-board electronics (OBE)

Servo solenoid valves with on-board electronics (OBE) Servo solenoid valves with on-board electronics (OBE) RE 29077/01.05 1/16 Replaces: 01.03 Type 4WRVE10...25 Size 10, 16, 25 Unit series 2X Maximum working pressure P, A, B 350 bar, T, X, Y 250 bar Nominal

More information

GLOBAL STANDARD COOLER

GLOBAL STANDARD COOLER GLOBAL STANDD COOLER GLOBAL STANDD RUGGED ENVIRONMENT COOLING SYSTEMS PRODUCT INFORMATION AKG CooL-Line is a standard line of products from the market leader in high performance aluminium cooling systems.

More information

Valve Accessories. Limit switches, solenoid valves, lock-up valves, supply pressure regulators, volume boosters, quick exhaust valves, applications

Valve Accessories. Limit switches, solenoid valves, lock-up valves, supply pressure regulators, volume boosters, quick exhaust valves, applications Valve Accessories Limit switches, solenoid valves, lock-up valves, supply pressure regulators, volume boosters, quick exhaust valves, applications SMART IN FLOW CONTROL. Our expertise for you Competence

More information

3/3 servo directional control valve with mechanical position feedback

3/3 servo directional control valve with mechanical position feedback Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic neumatic Electrical Mechanical () 426-4 www.cmafh.com 3/3 servo directional control valve with mechanical position feedback Type 4WS2EM...XN...-114

More information

FULLY WELDED BALL VALVES

FULLY WELDED BALL VALVES FULLY WELDED BALL VALVES 2 PERFORMANCE FROM START TO FINISH Ensuring the safety of the entire pipeline system requires the valves for oil and gas applications to be able to meet the most challenging demands.

More information

INDUCTIVE SENSORS FOR ROTARY ACTUATORS. Sense it! Connect it! Bus it! Solve it!

INDUCTIVE SENSORS FOR ROTARY ACTUATORS. Sense it! Connect it! Bus it! Solve it! INDUCTIVE SENSORS FOR ROTARY ACTUATORS Sense it! Connect it! Bus it! Solve it! Inductive sensors for rotary actuators Versatility in a compact and robust design Position control on actuators and drives

More information

Return Line Filter RFM with 4-Hole Mounting

Return Line Filter RFM with 4-Hole Mounting Return Line Filter with 4-Hole Mounting Tank-top mounted versions: up to 850 l/min, up to 10 bar 75 90 150 165 185 195 210 270 330 500 600 661 851 1. TECHNICAL SPECIFICATIONS 1.1 FILTER HOUSING Construction

More information

Filters. HF2P 79.4 Series Service and Parts. Index P Clogging. Indicator Port G 1/

Filters. HF2P 79.4 Series Service and Parts. Index P Clogging. Indicator Port G 1/ 2.05 52 3.39 86 0.24 6 0.84 21.4 P Clogging Filters Indicator Port G 1/2 4.02 102 3.13 HF2P 79.4 Series Service and Parts INLET OUTLET This symbol is followed 3.86 by user tips and particularly useful

More information

PF Pressure Plate Filter. Recovery of clear filtrates

PF Pressure Plate Filter. Recovery of clear filtrates PF Pressure Plate Filter Recovery of clear filtrates Administrative building of BHS-Sonthofen The company BHS-Sonthofen, headquartered in Sonthofen, Germany, is an owner-operated group of companies in

More information

Inline Filter MFM. Flow rates up to 100 l/min Pressure range up to 280 bar Material: EN-GJS / steel E /01.04

Inline Filter MFM. Flow rates up to 100 l/min Pressure range up to 280 bar Material: EN-GJS / steel E /01.04 Inline Filter MFM Flow rates up to 100 l/min Pressure range up to 280 bar Material: EN-GJS 400-15 / steel 1. TECHNICAL SPECIFICATIONS 1.1. FILTER HOUSING Construction The inline filter consists of a filter

More information

GLOBAL STANDARD COOLER

GLOBAL STANDARD COOLER COOLER H H OIL-To-AIR COOLING SYSTEMS WITH HYDRAULIC MOTOR Product Information AKG-Line is a standard line of products from the market leader in high performance aluminium cooling systems. AKG is best

More information

Axial Piston Fixed Motor A2FM

Axial Piston Fixed Motor A2FM Axial Piston Fixed Motor A2FM RE 91001/06.2012 1/46 Replaces: 09.07 Data sheet Series 6 Size Nominal pressure/maximum pressure 5 315/350 bar 10 to 200 400/450 bar 250 to 1000 350/400 bar Open and closed

More information

DESYsmart / TESYsmart steam test unit

DESYsmart / TESYsmart steam test unit 0 DESYsmart / TESYsmart steam test unit Electronic pressure monitoring system for controlling fittings with safetyrelevant tasks in accordance with TRD 4, DIN EN ISO46, AD data sheet A and safety concept

More information