1 Series 3 Application For decades, Danfoss has been the world s leading manufacturer of radiator valves and radiator thermostats. Danfoss invented the radiator thermostat back in 1943 and later developed it. Today, radiators are often manufactured with integrated valves (i.e. built-in valves), which are built into the radiator at the time of manufacture, the radiator thermostat being fitted on site by the installer. Radia- tors with integrated valves are known as valve radiators or compact radiators. As an alternative to the well-established RA-N and RA-U valves, Danfoss has developed integrated valves for use with valve radiators. Danfoss integrated valves fit all valve radiators and guarantee the same efficient operation as other Danfoss valves. Advantages used with valve radiators offer the following advantages: Ÿ Valve housings have been pre-installed prior to delivery to site. Ÿ Pipe connections do not have to be soldered or welded. Connections: Rp 1/2" inside thread or G 3/4" outside thread. Ÿ Quicker installation. Ÿ Presetting as an integrated feature. Ÿ Elegant design with hidden piping. Ÿ Pipe connections are made underneath the radiator - which is a great advantage in horizontal piping installations. Ÿ By mounting a special bypass union it is possible to change from two-pipe operation to one-pipe operation and to drain and disconnect the radiator from the system.

2 Processing by the radiator manufacturer a) Valve radiator with valve insert b) Valve radiator with integrated valve In principle, the valve radiator consists of: Ÿ A heating surface made of plates or pipes. Ÿ A welded-on fitting, in which the integrated valve is fitted. Ÿ An integrated valve. The valve radiator is subsequently equipped with a radiator thermostat, once the heating installation is complete. The hydraulic parts of a valve radiator can be designed in two ways: a) Valve insert: In this case the valve seat is an integral part of the fitting. This solution requires very tight tolerances in the manufacturing and placing of the fitting, since the valve seat fitting and the insert will often come from two different manufacturers. b) Integrated valve: The valve seat is an integrated part of the integrated valve. The responsibility for the whole hydaulic solution thus rests with the valve manufacturer. provide maximum assurance of the reliable operation of valve radiators. That is why Danfoss has decided to manufacture integrated valves rather than valve inserts. Fittings The fitting has been welded or soldered into the radiator. It consists of three parts: Ÿ valve fitting for integrated valve, Ÿ connection fittings for pipe connections, Ÿ riser pipes, connecting the valve and connection fittings. All Danfoss integrated valves are supplied with built-in presetting feature. The valve fitting is placed so as to allow the integrated valve to be screwed into the end of the radiator. The connection fitting has been designed for two-pipe operation with floor connection (for one-pipe operation and wall connection, see p. 4). Note: Danfoss matches the design of its integrated valves with the different fittings used by radiator manufacturers. 2

3 Construction 1. Gland seal pin 2. Gland seal 3. Presetting ring 4. Adapter thread (M23.5x1.5) and element attachment 5. Large O-ring 6. Connection thread G ½" 7. k v insert 8. Discharge opening 9. Valve cone 10. Valve seat 11. Small O-ring Installation of integrated valves are normally installed during the manufacturing of valve radiators. That is why the installation process has to be automatic or semi-automatic. Danfoss will assist radiator manufacturers with advice on installation techniques. Because of the thermal load limit of the sealants (120 C), the valves should not be installed until the radiators have been powder-lacquered. The integrated valve should be tightened into the fitting using a torque of 30 Nm (±10%). A cap is provided to protect the integrated valve against damage in transit and during the construction phase. Dimensions of threads and installation tools: Valve inside thread: G ½" Valve installation: 12-point box spanner or ring spanner, Key width 21 Gland seal: Key width 10 Radiator thermostats Danfoss integrated valves have been developed primarily for use in combination with Danfoss RA 2000 series radiator thermostats. Danfoss thermostats are easy, quick and simple to install because of their patented snap-on connection feature. More detailed information on RA 2000 is available from data-sheets, operating instructions and general instructions. 3

4 One-pipe and two-pipe installations One-pipe installation Today, most valve radiators are made for two-pipe operation as standard. Conversion to one-pipe operation is effected by installing special bypass unions. These unions also make it possible to drain and disconnect the radiators from the system. By mounting the relevant unions on the fittings, it is possible to choose either wall or floor connection. One-pipe installation In a one-pipe installation, there is normally a demand for high flow rates through the radiators, whilst the differential pressure is low. This is why the k v values should be relatively high (approx ). An integrated valve type 013G0370 (RA-N) with pre-setting "N" must be mounted. The distribution of Two-pipe installation water between radiator and bypass can be set on the bypass union in accordance with the pipe network calculations. In this situation the pre-set position is always N. Two-pipe installation In a two-pipe installation, the k v values should be pre-set for each radiator in accordance with the pipe network calculations. Values are set easily and simply by means of the pre-setting ring on the valves. Danfoss is able to offer two capacity ranges for two-pipe installations: a) A range for large volume flows (Nvalves). b) A range for small volume flows, e.g. district heating installations with big temperature differences (U-valves). Code nos. and technical data Max. pressure Recomm. Max. Connec- Presetting Diffe- Test dimensional water Code No. tion Working k v -value 1) 3) k vs rential 2) press. diff. press. temp. thread N N bar bar bar bar C 013G0370 G ½A up to G0371 G ½A ) k v values indicate the flow volume (Q) in m 3 /h at a pressure loss (Dp) across the valve of 1 bar. k v = Q Dp. At setting N, the k v value in accordance with EN can be stated as Xp = 2 K. At lower preset values, Xp is lowered to setting 1, where Xp = 0.5 K. The k v values indicate the valve capacity, when the valve is fully open. 2) The max. differential pressure is the maximum recommended differential pressure that the valve should be exposed to if satisfactory regulation is to be ensured. To obtain low-noise operation, it is recommended to choose pumps that match system pressure losses. Experience indicates that in most two-pipe installations a differential pressure across the valves of bar is sufficient. The differential pressure can be reduced by using a Danfoss differential pressure regulator. 3) When using a RAW radiator thermostat, the P-Band will be increased by factor 1.6. RAW at setting N aligns manufacturers information of EN 215. The setting values can be read directly from the table above: k v = Q (m 3 /h) Dp (bar) Other technical informations can be found in the product data-sheets. 4

5 Spare-parts and accessories Product pcs./pack Code no. Gland seal 10 pcs. 013G0290 The valve gland seal can be replaced without the need to drain the system. Capacity The two integrated valves (013G0370 and 013G0371) have k v values and recommended setting ranges which partly overlap. P-band: The p-band of a valve is the change of room temperature which is necessary to move the valve from closed position to the position that allows the desired volume flow to pass (in relation to the dimension chosen). Because of the good regulating feature of the RA 2000 thermostat, we recommend that the valves be sized with a p-band of between 0.5 and 2 K. Presetting Reference mark Reference mark Factory setting and one-pipe system Presetting range The dimensioned presetting values of the integrated valves of types RA-N and RA- U, can be adjusted easily and accurately without the use of tools (factory setting: N): Ÿ Remove the protective cap of the radiator thermostat. Ÿ Find the reference mark. Ÿ Turn the setting ring until the desired presetting aligns with the reference mark. Ÿ Control that the setting is correct. The presetting is controlled directly without the use of equipment. After installation in the radiator, the reference mark of the valve will not always be positioned in the same place. Presettings can be selected within the range of 1 to 7 steps. At N setting the valve is fully open. Setting in the shaded areas of the drawing should be avoided. In a one-pipe installation, the N setting must be used. For Danfoss elements RA 2000 and RAW, a theft protection device is available; this provides added security against unwanted adjustment of the preset values. Design work Different standard software programmes can be used for calculating pipe networks. These programmes are updated regularly as new information is released by the radiator manufacturers. The programmes are not sold by Danfoss. By means of software or calculations of pipe networks, it is possible to find the necessary preset values for the integrated valves in two-pipe installations. In a one-pipe installation, software or calculation can be used to find the necessary oversize of radiators and to calculate the water supply share to be assigned to the individual radiator. Since many programmes also contain dimensioning data for differential pressure regulators and volume regulators, the project manager can include all necessary regulation components in the same calculation. 5

6 Installation work on site Installation work is limited to attaching and adjusting the radiator, installing any unions or clamping ring fittings, presetting the valve and installing the sensor. It is extremely easy to preset the water flow with a Danfoss integrated valve. It requires no tools, is easy to read and can be checked at any time by the project manager and site manager. In the N position the presetting of the valve is cancelled. This position can be used if the installation is to be flushed. In the case of one-pipe installations, attention should be paid to the fact that the bypass unions contain parts to prevent unwanted heat emission. Installation instructions for Danfoss radiator thermostats are printed on the packaging. Unwanted heat emission in one-pipe installation When the valve is closed, the radiator can be heated by heat conduction from the connection fitting, through which there is a constant flow. The extent of such unwanted heat emission depends on the design of the fitting, the flow temperature and the volume flow. Unwanted heat emission can be reduced in such installations, but not completely eliminated. Sound measurements Under certain conditions, a heating installation can generate noise which can become a nuisance. The most important factors in the formation of such noise are the pipe system, the flow volume, the differential pressure, the hydraulics of the valve, the temperature conditions and - not least - the type of radiator in use. Danfoss carries out noise measurements on integrated valves installed in the radiator manufacturer s products as part of an ongoing cooperation with the manufacturer. To prevent noise from the water flow the differential pressure should not exceed 0.2 bar. ISO quality inspection Danfoss has held an ISO 9000 certificate for many years. ISO certification ensures that development, design and construction are carried out in accordance with the quality requirements contained in ISO 9001 and Final inspection is carried out in accordance with ISO

7 Danfoss radiator thermostats Radiator thermostat RA2000 with snaplock RA 2610 RA 2612 with remote sensor Type Model Version Setting range Code no. RA 2610 Built-in sensor 013G2610 Universal 5-26 C RA 2612 Remote sensor 0-2 m 013G2612 Radiator thermostat type RA 2020, tamperproof model RA 2020 RA 2022 Type Model Version Setting range Code no. RA 2020 Tamper- Built-in sensor 013G C RA 2022 proof Remote sensor 0-2 m 013G2022 Remote temperature adjusters Remote temperature adjuster RA5060 Type Model Version Setting range Code no. RA 5062 Remote With 2 m capillary 013G5062 RA 5065 temp. With 5 m capillary 8-28 C 013G5065 RA 5068 adjuster With 8 m capillary 013G5068 Consult the detailed data-sheets for further information on Danfoss radiator thermostats and accessories for radiator thermostats. 7

8 Danfoss A/S Hårupvænget 11 Hårup DK-8600 Silkeborg - Denmark Telefon: Telefax:

Integrated Presetting Valves for Normal (013G0380) and Small (013G0381) Volume Flows

Integrated Presetting Valves for Normal (013G0380) and Small (013G0381) Volume Flows Integrated Presetting Valves for Normal (013G0380) and Small (013G0381) Volume Flows Application Integrated valves, type RA-N (013G0380) and RA- U (013G0381), with built-in presetting are designed for

More information

Integrated Presetting Valves - for Normal Volume Flows RA-N and for Small Volume Flows RA-U

Integrated Presetting Valves - for Normal Volume Flows RA-N and for Small Volume Flows RA-U Integrated Presetting Valves - for Normal Volume Flows RA-N and for Small Volume Flows Application RA-N 013G7382 013G7387 Integrated valves, type RA-N 013G7382 and 013G7387, with built-in presetting are

More information

Integrated Valve with Presetting for Manifolds in Two-Pipe Heating Systems

Integrated Valve with Presetting for Manifolds in Two-Pipe Heating Systems Data Sheet Integrated Valve with Presetting for Manifolds in Two-Pipe Heating Systems The integrated valve is designed for manifold applications in combination with a system connection piece. Valve and

More information

High capacity valve body, type RA-G

High capacity valve body, type RA-G Application The RA-G valves are fitted with a grey protective cap. This protective cap must not be used as a manual shut off device. A special manual shut off device is available (code no. 013G3300). The

More information

High Capacity Valve Body, Type RA-G

High Capacity Valve Body, Type RA-G Data Sheet The RA-G valves are fitted with a grey protective cap. This protective cap must not be used as a manual shut off device. A special manual shut off device is available (code no. 013G3300). Application

More information

Dynamic Valve Type RA-DV Pressure Independent Radiator Valve

Dynamic Valve Type RA-DV Pressure Independent Radiator Valve Dynamic Valve Type RA-DV Pressure Independent Radiator Valve Application RA-DV straight version RA-DV angle version RA-DV angle Right & Left RA-DV UK (Axial) RA-DV is a series of pressure independent radiator

More information

Valve bodies type RA-N with integrated presetting

Valve bodies type RA-N with integrated presetting Data Sheet Application Straight version Angle version Left mounted angle version Horizontal angle version All RA-N valve bodies can be used together with all types of thermostatic elements in the RA 2000

More information

Floor heating system, heating circuit with FHV-A in flow.

Floor heating system, heating circuit with FHV-A in flow. Application FHV control valves are ideally suited for controlling the temperature of individual under-floor heated rooms and for systems using floor-heating in conjunction with radiators. Danfoss offers

More information

X-tra Collection for designer radiators and bathroom towel rails

X-tra Collection for designer radiators and bathroom towel rails and bathroom towel rails Application The new X-tra Collection is a TRV specially designed for towel rails and designer radiators. Its new and innovative self-sealing ½" valve to radiator connection makes

More information

X-tra Collection for designer radiators and bathroom towel rails

X-tra Collection for designer radiators and bathroom towel rails and bathroom towel rails Application The new X-tra Collection is a TRV specially designed for towel rails and designer radiators. Its new and innovative self-sealing ½" valve to radiator connection makes

More information

RA-N Valve Bodies with Pressfit Connection and Self-Sealing Tailpiece for Two Pipe Systems

RA-N Valve Bodies with Pressfit Connection and Self-Sealing Tailpiece for Two Pipe Systems Data Sheet RA-N Valve Bodies with Pressfit Connection and Self-Sealing Tailpiece for Two Pipe Systems Application Straight Angle The valve bodies with pressfit connection are used for heating systems with

More information

Valve bodies with pressfit connection and self-sealing tailpiece. Type RA-N for two pipe systems

Valve bodies with pressfit connection and self-sealing tailpiece. Type RA-N for two pipe systems Valve bodies with pressfit connection and self-sealing tailpiece. Type RA-N for two pipe systems EN 215 Application Straight Angle Horizontal angle The valve bodies with pressfit connection are used for

More information

T6-PLAN CENTRALLY CONNECTED RADIATOR.

T6-PLAN CENTRALLY CONNECTED RADIATOR. 50 T6-PLAN CENTRALLY CONNECTED RADIATOR Technical data T6-PLAN CENTRALLY CONNECTED RADIATOR. Connections 4 x internal thread G 1/2 and 2 x external thread G 3/4 bottom centre 10 bar max. Max. positive

More information

Automatic balancing valves ASV-PV DN (3rd gen.)

Automatic balancing valves ASV-PV DN (3rd gen.) Automatic balancing valves ASV-PV DN 50-100 (3rd gen.) Description / Application Partner valve ASV-PV DN 50 ASV-PV DN 65-100 MSV-F2 DN 50-100 ASV balancing valves are used for dynamic hydronic balance

More information

Hudevad Integral. Technical datasheet

Hudevad Integral. Technical datasheet Technical datasheet Key benefits $ Sleek flat front Minimalistic design Pressure tested at high pressure Approved for district heating Historical Kundenedfald Highly flexible in size Huge range of dimensions

More information

AVQMT. AVQT controller can be combined with AVT or STM thermostatic actuators.

AVQMT. AVQT controller can be combined with AVT or STM thermostatic actuators. Data sheet Flow and temperature controller with / without integrated control valve (PN 25) AVQT - flow and temperature controller AVQMT - flow and temperature controller with integrated control valve Description

More information

Hudevad LK. Technical datasheet

Hudevad LK. Technical datasheet Technical datasheet Key benefits Kundenedfald Grøn energi Swedish high quality steel Highly robust and durable Fully welded solution No removable parts, making it highly durable and completely tamper-proof

More information

Capacity regulators (hot gas bypass) PMC and CVC

Capacity regulators (hot gas bypass) PMC and CVC MAKING MODERN LIVING POSSIBLE Technical brochure Capacity regulators (hot gas bypass) PMC and CVC The PMC and CVC is used for capacity regulation in refrigeration, freezing and air conditioning plant for

More information

Temperature controller (PN 25) AVT / VG - external thread AVT / VGF - flange

Temperature controller (PN 25) AVT / VG - external thread AVT / VGF - flange Data sheet Temperature controller (PN 25) AVT / VG - external thread AVT / VGF - flange Description AVT / VG The AVT / VG(F) controller is a self-acting proportional temperature controller developed primarily

More information

V2000FS FS type TRV Body FINELY PRESETTABLE RADIATOR VALVE WITH FLUSH POSITION

V2000FS FS type TRV Body FINELY PRESETTABLE RADIATOR VALVE WITH FLUSH POSITION V2000FS FS type TRV Body FINELY PRESETTABLE RADIATOR VALVE WITH FLUSH POSITION PRODUCT DATA Application 011 Angle to DIN Angle to NF Straight to DIN Straight to NF Thermostatic radiator valve bodies (TRV

More information

Temperature controller for heating (PN 25) AVT / VG - external thread AVT / VGF - flange

Temperature controller for heating (PN 25) AVT / VG - external thread AVT / VGF - flange Data sheet Temperature controller for heating (PN 25) AVT / VG - external thread AVT / VGF - flange Description AVT / VG AVT / VGF The AVT / VG(F) controller is a self-acting proportional temperature controller

More information

Manual presetting valve MSV-C

Manual presetting valve MSV-C Description / Application MSV-C is used for balancing the flow in cooling, heating and domestic water systems. MSV-C is a combined manual presetting valve with following features: Fixed measurement orifice.

More information

Injection valve, type TXI 2 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Injection valve, type TXI 2 REFRIGERATION AND AIR CONDITIONING. Technical leaflet Injection valve, type TXI 2 REFRIGERATION AND AIR CONDITIONING Technical leaflet Introduction Danfoss has developed a injection valve type TXI 2 for desuperheating in 2-stage refrigeration systems operating

More information

Thermostatic actuator RAVI - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)

Thermostatic actuator RAVI - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) Description RAVI is self-acting thermostatic actuator primarily for use for temperature control of small hot water cylinders - either storage

More information

Injection valve Type TXI 2

Injection valve Type TXI 2 Data sheet Injection valve Type TXI 2 The TXI2 is an injection valve for desuperheating in 2-stage refrigeration systems operating on R22/R407C and other similar refrigerants where the hot gas temperature

More information

FHV control valves are flexible to use, easily installed and are available in two versions:

FHV control valves are flexible to use, easily installed and are available in two versions: FHV-A/FHV-R Application: FHV-A FHV-R The floor-heating valve (FHV) provides an economical method of incorporating a radiant floor heating system into an existing hot water or radiator system. FHV self-acting

More information

Pressure and temperature regulators, type PM, and pilot valves

Pressure and temperature regulators, type PM, and pilot valves Pressure and temperature regulators, type PM, and pilot valves Introduction Main valves, type PM 1 and PM 3 Pilot valves for mounting directly into main valves, type PM Main valves, type PM 1 and PM 3

More information

Pressure independent balancing and control valve

Pressure independent balancing and control valve Pressure independent balancing and control valve AB-QM DN 10-150 AB-QM valve equipped with an actuator is a control valve with full authority and automatic balancing function - flow limiter. Typical applications

More information

Flow-compensated temperature controller AVTQ DN 15

Flow-compensated temperature controller AVTQ DN 15 Data sheet Flow-compensated temperature controller AVTQ DN 15 Description AVTQ is a self-acting flow-compensated temperature controller primarily for use in district heating systems with plate heat exchangers

More information

TDU.3 floor distribution unit SK

TDU.3 floor distribution unit SK SK General description and application The is intended for two pipe horizontal heating systems and includes connecting, measuring, regulating and distribution functions. The TDU.3 is easily installed on

More information

Temperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25)

Temperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25) Data sheet Temperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25) Description Controller closes on rising temperature. The controllers are: - Type-tested acc. to EN 14597

More information

MAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional

MAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional Y + U I COADIS COMBI High pressure and high ductable units Motor optional is a non independent air conditioning terminal unit for heating and cooling offices and hotels. With reduced dimensions and designed

More information

Hudevad Flat Front. Technical datasheet

Hudevad Flat Front. Technical datasheet Technical datasheet Key benefits $ Completely sealed casing Clean and tamper-proof design Pressure tested at high pressure Approved for district heating Historical Kundenedfald Highly flexible in size

More information

Premounted Midi Shunts

Premounted Midi Shunts Application Midi Shunt 088U0181 - with one circuit Midi Shunt 088U0182 - with two circuits Midi Shunt 088U0183 - with three circuits The Danfoss floor heating midi shunt is a series of pre-mounted shunts

More information

Pressure independent control valve with integrated flow limiter AVQM (PN 16) - return and flow mounting

Pressure independent control valve with integrated flow limiter AVQM (PN 16) - return and flow mounting Data sheet Pressure independent control valve with integrated flow limiter AVQM (PN 16) - return and flow mounting Description Controllers are used together with Danfoss electrical actuators: AMV 0 1)

More information

Automatic metal-edge filters AF 72 G

Automatic metal-edge filters AF 72 G Automatic metal-edge filters AF 72 G with radial scraper cleaning Connection size G1 1/2, flange DN 40 1 Short description MAHLE automatic metal-edge filters are suitable for all applications where low

More information

Automatic metal-edge filter AF 71 G

Automatic metal-edge filter AF 71 G Automatic metal-edge filter AF 71 G with radial scraper cleaning Connection size G1 1 Features MAHLE automatic metal-edge filters are suitable for all applications where low or high-viscosity liquids or

More information

Combined automatic balancing valve AB-PM valve DN 15-25, PN 16

Combined automatic balancing valve AB-PM valve DN 15-25, PN 16 Data sheet Combined automatic balancing valve AB-PM valve DN 15-25, PN 16 Description AB-PM is a combined automatic balancing valve. It features three function in compact valve body: 1. Differential pressure

More information

Flow controller with integrated control valve (PN 16) AHQM - return and flow mounting

Flow controller with integrated control valve (PN 16) AHQM - return and flow mounting Flow controller with integrated control valve (PN 16) AHQM - return and flow mounting Description Controllers are used together with Danfoss electrical actuators: DN 15-32 with - AMV(E) 10 - AMV(E) 13

More information

We proudly deliver a unique and

We proudly deliver a unique and Linear 3-Way Control Valve PN 10/16/25, DN15 - DN300 BENEFITS Nominal pressure PN 16 Almost linear Two balance single seats kvs Regulating capability > 25 kvr Leakage 0.05% of kvs For regulating of process

More information

better measurement Simply a question of

better measurement Simply a question of Simply a question of better measurement SCHMIDT Flow Sensor SS 2.415 and SS 2.515 The tried and tested measurement experts for the monitoring of laminar flows extremely precise and quickly installed Industrial

More information

FCU Floor Control Unit

FCU Floor Control Unit Fully assembled with integrated M3V Control Group including mixing valve and circulating pump and in-line high and low temperature Topway T2 FM manifold options with high and low temperature manifold options

More information

Hudevad Standard. Technical datasheet

Hudevad Standard. Technical datasheet Technical datasheet Key benefits $ Swedish high quality steel Highly robust and durable Pressure tested at high pressure Approved for district heating Historical Kundenedfald Highly flexible in size Huge

More information

HG Series Aluminium Design

HG Series Aluminium Design HG Series Aluminium Design Semi-hermetic compressors in aluminium design for mobile applications 1 At a glance Based on our compressors of the Pluscom series with their outstanding advantages and features,

More information

Temperature controller AVT with safety temperature monitor STM/VG(F) (PN25)

Temperature controller AVT with safety temperature monitor STM/VG(F) (PN25) Data sheet Temperature controller AVT with safety temperature monitor STM/VG(F) (PN25) Description Controller closes on rising temperature. TR1240 The controllers are: Type-tested acc. to EN 14597 and

More information

Data sheet. Thermostatically operated cooling water valves Type FJVA. January 2000 DKACV.PD.500.B B0033

Data sheet. Thermostatically operated cooling water valves Type FJVA. January 2000 DKACV.PD.500.B B0033 Data sheet Thermostatically operated cooling water valves January 2000 DKACV.PD.500.B1.02 520B0033 General data on thermostatically operated cooling water valves Introduction Thermostatically operated

More information

Refrigeration and Air Conditioning Controls. Technical leaflet. Stop valves type SVA 6-10 REFRIGERATION AND AIR CONDITIONING

Refrigeration and Air Conditioning Controls. Technical leaflet. Stop valves type SVA 6-10 REFRIGERATION AND AIR CONDITIONING Refrigeration and Air Conditioning Controls Technical leaflet Stop valves type SVA 6-10 REFRIGERATION AND AIR CONDITIONING Contents Page Introduction... 3 Features... 3 Design... 4 Technical data... 4

More information

Premounted Midi Shunts

Premounted Midi Shunts Application Midi Shunt 088U0181 - with one circuit Midi Shunt 088U0182 - with two circuits Midi Shunt 088U0183 - with three circuits The Danfoss floor heating midi shunt is a series of pre-mounted shunts

More information

Installation Guide. ECL Comfort 210 / 310, application A231 / A Table of Contents

Installation Guide. ECL Comfort 210 / 310, application A231 / A Table of Contents 1.0 Table of Contents 1.0 Table of Contents... 1 1.1 Important safety and product information..................... 2 2.0 Installation... 4 2.1 Before you start.....................................................

More information

Flow controller (PN 25) AVQ - return and flow mounting

Flow controller (PN 25) AVQ - return and flow mounting Data sheet Flow controller (PN 5) - return and flow mounting Description is a self-acting flow controller primarily for use in district heating systems. The controller closes when set max. flow is exceeded.

More information

Technote. Frese ALPHA - automatic balancing valve. Application. Benefits. Features.

Technote. Frese ALPHA - automatic balancing valve. Application. Benefits. Features. Page 1 of 6 Application The Frese APHA Valves are particularly designed and manufactured for the automatic balancing of heating and cooling circuits. The Frese APHA Cartridges - the second generation cartridges

More information

Angle Pattern Thermostatic Radiator Valve Vertical or horizontal mounting (15mm)

Angle Pattern Thermostatic Radiator Valve Vertical or horizontal mounting (15mm) Angle Pattern Thermostatic Radiator Valve Vertical or horizontal mounting (15mm) GENERAL INFORMATION Size Pattern No. Pack 1 Qty Code Barcode 8mmx1/2 Angle Pattern TRV 1 632001 5013866012099 10mmx1/2 Angle

More information

Flow Control and Differential Pressure Controller AFPQ / VFQ 2(21) - Installation in return line AFPQ 4 / VFQ 2(21) - Installation in flow line

Flow Control and Differential Pressure Controller AFPQ / VFQ 2(21) - Installation in return line AFPQ 4 / VFQ 2(21) - Installation in flow line Flow Control and Differential Pressure Controller AFPQ / VFQ 2(21) - Installation in return line AFPQ 4 / VFQ 2(21) - Installation in flow line Description / Application AFPQ VFQ AFPQ 4 VFQ The controller

More information

Differential pressure controller AFP / VFG 2 (VFG 21)

Differential pressure controller AFP / VFG 2 (VFG 21) Differential pressure controller AFP / VFG 2 (VFG 21) Description AFP VFG2 (VFG 21) is a self-acting differential pressure controller primarily for use in district heating systems. The controller closes

More information

Differential pressure controller AFP / VFG 2 (VFG 21)

Differential pressure controller AFP / VFG 2 (VFG 21) Differential pressure controller AFP / VFG 2 (VFG 21) Description / Application AFP VFG2 (VFG 21) is a self-acting differential pressure controller primarily for use in district heating systems. The controller

More information

MODULOAD CAPACITY CONTROL FOR 3D COMPRESSORS

MODULOAD CAPACITY CONTROL FOR 3D COMPRESSORS 21-1278 Application Engineering Bulletin AE-1278-R5 Revised February, 1997 MODULOAD CAPACITY CONTROL FOR 3D COMPRESSORS On refrigeration and air conditioning applications where the refrigeration load may

More information

2 - way valve (NO), pressure relieved (PN 25) VG - external thread VGF - flange

2 - way valve (NO), pressure relieved (PN 25) VG - external thread VGF - flange Data sheet 2 - way valve (NO), pressure relieved (PN 25) VG - external thread VGF - flange Description VG and VGF are pressure relieved 2-way normally open (NO) valves, designed to be combined with: -

More information

Ihr autorisierter Distributor: Neumüller Elektronik GmbH Motor Protectors

Ihr autorisierter Distributor: Neumüller Elektronik GmbH Motor Protectors 8AM 2AM-4AM 2AM/3AM/4AM/8AM Motor Protectors Proven products backed by the leading innovators in protection technology. Klixon automatic motor protectors (AM series) are small, light weight and sensitive

More information

Thermo. operated water valve Type WVTS

Thermo. operated water valve Type WVTS Data sheet Thermo. operated water valve Type WVTS Thermo. operated water valve type WVTS is suitable for controlling the temperature of a flow of water or neutral brine. WVTS opens on rising sensor temperature

More information

Automatic metal-edge filter AF 73 G/AF 93 G

Automatic metal-edge filter AF 73 G/AF 93 G Automatic metal-edge filter AF 73 G/AF 93 G with radial scraper cleaning Connection size G2, screw-in flange DN 50 and DN 65 1 Features MAHLE automatic metal-edge filters are suitable for all applications

More information

AE R5 February 1997 Reformatted November 2010

AE R5 February 1997 Reformatted November 2010 AE21-1278 R5 February 1997 Reformatted November 2010 Moduload Capacity Control for 3D Compressors On refrigeration and air conditioning applications where the refrigeration load may vary over a wide range,

More information

Thermostatically operated cooling water valves Type AVTA

Thermostatically operated cooling water valves Type AVTA Thermostatically operated cooling water valves Type AVTA Features AVTA Insensitive to dirt Insensitive to water pressure Needs no power supply - self acting Opens on rising sensor temperature Differential

More information

Combined automatic balancing valve AB-PM valve DN 10-32, PN 16

Combined automatic balancing valve AB-PM valve DN 10-32, PN 16 Data sheet Combined automatic balancing valve AB-PM valve DN 10-32, PN 16 Description AB-PM is a combined automatic balancing valve. It features three function in compact valve body: 1. Differential pressure

More information

Differential pressure controller AFP / VFG 2 (VFG 21)

Differential pressure controller AFP / VFG 2 (VFG 21) Differential pressure controller AFP / VFG 2 (VFG 21) Description AFP VFG2 (VFG 21) is a self-acting differential pressure controller primarily for use in district heating systems. The controller closes

More information

OML and OMM Orbital motors. Technical Information

OML and OMM Orbital motors. Technical Information OML and OMM Orbital motors Technical Information OML and OMM A wide range of orbital motors F300030.TIF A WIDE RANGE OF ORBITAL MOTORS Sauer-Danfoss is a world leader within production of low speed orbital

More information

DANFOSS. Thermostatic Expansion Valves. Nominal Capacity Ranges in TR for Range N -40 to 50 F R-12 R-22 R-410A R-134A R-404A/

DANFOSS. Thermostatic Expansion Valves. Nominal Capacity Ranges in TR for Range N -40 to 50 F R-12 R-22 R-410A R-134A R-404A/ TYPE TUA(E), TUB(E), TUC(E), T(E)2, TDE, TDEB, TE, TXI 2, AKV Thermostatic Expansion Valves Valve Applications Features Models Nominal Capacity Ranges in TR for Range N -40 to 50 F R-12 R-22 R-410A R-134A

More information

Please refer to our catalogue for details of the full product range

Please refer to our catalogue for details of the full product range Thermostatic Radiator Valve Bodies Series V6 - Double Regulating Function ngle Pattern 118 37 63 118 37 64 11.10 11.10 EPDM disk & seals (see note below) F x MU ends Thermostat connection thread M30 x

More information

Expansion valves - 2 of 2

Expansion valves - 2 of 2 Expansion valves - 2 of 2 Contents Page Thermostatic expansion valves, type T 2 and TE 2 Introduction... 3 Features... 3 Technical data... 3 Superheat... 3 Ordering: Components with flare flare connection...

More information

Flow controller with integrated control valve (PN 16) AHQM return and flow mounting

Flow controller with integrated control valve (PN 16) AHQM return and flow mounting Data sheet Flow controller with integrated control valve (PN 16) AHQM return and flow mounting Description DN 15-32 DN 40, 50 DN 50-100 DN 125 DN 150 DN 200, 250 AHQM is a self-acting flow controller with

More information

Shut-off valves in stainless steel SVA-S SS

Shut-off valves in stainless steel SVA-S SS Technical brochure Shut-off valves in stainless steel In certain specific areas such as outdoor applications and corrosive atmospheres, such as coastal installations, there is a need for high surface protection

More information

Complete Systems for Light Assembly

Complete Systems for Light Assembly F I X I N G S Y S T E M S Complete Systems for Light Assembly Individual assembly system for installing lamp systems can often be realised only at high cost with one-off manufacture. The patented Complete

More information

Pressure controls and thermostats, type KPS

Pressure controls and thermostats, type KPS KPS pressure controls are fitted with a 3 mm steel mounting plate. The units should not be allowed to hang from the pressure connection. Pressure connection When fitting or removing pressure lines, the

More information

Flow controller (PN 25) AVQ - return and flow mounting

Flow controller (PN 25) AVQ - return and flow mounting Data sheet Flow controller (PN 5) - return and flow mounting Description is a self-acting flow controller primarily for use in district heating systems. The controller closes when set max. flow is exceeded.

More information

TONISCO System Oy Kalkun kehätie Tampere FINLAND Tel

TONISCO System Oy Kalkun kehätie Tampere FINLAND Tel TONISCO RED LINE HOT TAPPING MACHINES for dimensions DN0 (3/8") - DN200 (8") For under pressure hot tappings through DANFOSS & TONISCO valves TONISCO System Oy Kalkun kehätie 9 33330 Tampere FINLAND Tel.

More information

Differential pressure relief controller (PN 16, 25, 40) AFPA / VFG 2(1)

Differential pressure relief controller (PN 16, 25, 40) AFPA / VFG 2(1) Data sheet Differential pressure relief controller (, 25, 40) AFPA / VFG 2() Description The controller has a control valve, an actuator with one control diaphragm and spring for differential pressure

More information

Pressure and temperature controls, Type CAS

Pressure and temperature controls, Type CAS MAKING MODERN LIVING POSSIBLE Pressure and temperature controls, Type CAS The CAS Series consists of a series of pressure controlled switches and temperature controlled switches. In this series, special

More information

Data sheet Pressure controls and thermostats type CAS August 2000 DKACT.PD.P10.B B0616

Data sheet Pressure controls and thermostats type CAS August 2000 DKACT.PD.P10.B B0616 Data sheet Pressure controls and thermostats type CAS August 2000 DKACT.PD.P10.B2.02 520B0616 Pressure controls, type CAS Range Further 0 10 20 30 40 50 60 bar p e Type information bar page Standard pressure

More information

Data sheet Pressure independent control valve with integrated flow limiter AVQM (PN 16) - return and flow mounting

Data sheet Pressure independent control valve with integrated flow limiter AVQM (PN 16) - return and flow mounting Pressure independent control valve with integrated flow limiter AVQM (PN 16) - return and flow mounting Description Controllers are used together with Danfoss electrical actuators: - AMV 150 1) - AMV(E)

More information

Pressure independent balancing and control valve AB-QM DN

Pressure independent balancing and control valve AB-QM DN Pressure independent balancing and control valve AB-QM DN 10-150 AB-QM valve equipped with an actuator is a control valve with full authority and automatic balancing function - flow limiter. Typical applications

More information

Multiflex Fittings. Technical information

Multiflex Fittings. Technical information Technical information Tender specification: (examples) Oventrop connection fittings made of nickel plated brass, for the connection of radiators with integrated distributor G ¾ male thread Euro ). ZB preset

More information

Your Personal Catalog Temperature Controllers All our know-how - is now yours

Your Personal Catalog Temperature Controllers All our know-how - is now yours MAKING MODERN LIVING POSSIBLE Your Personal Catalog Temperature Controllers All our know-how - is now yours Index 3 RAVI 12 RAVK 20 RAVV 28 AFT 06/26/17/27 33 AVTB 41 AVTQ DN15 49 AVTQ DN20 57 FJV 61 STFW/VFG(S)

More information

Lockshield valves with Pressfit connection Type RLV with isulation and regulation

Lockshield valves with Pressfit connection Type RLV with isulation and regulation Data sheet Lockshield valves with Pressfit connection Type RLV with isulation and regulation Application RLV Straight pattern RLV Angle pattern Drain-cock The valve bodies with pressfit connection are

More information

Listings and Approvals. G5 QR Gasket culus QR G5 SR Gasket culus, FM SR G5

Listings and Approvals. G5 QR Gasket culus QR G5 SR Gasket culus, FM SR G5 Model Series Sprinklers Available with Solid, Perforated, or Gasket Standard Coverage, Concealed Pendent K2.8, 4.2, 5.6, & 8.0 (40, 60, 80, & 115 metric) Features Flat concealed cover plate available solid

More information

The valves can be controlled electronically by thermal actuators or act as self-acting units by means of remote temperature adjusters.

The valves can be controlled electronically by thermal actuators or act as self-acting units by means of remote temperature adjusters. Floor Heating Manifold FHF Application The Manifold FHF is used for controlling water flow in under floor heating systems. Each tube of the floor heating system is connected to the manifold, thus making

More information

SSM Floor Heating Manifold

SSM Floor Heating Manifold Application The manifold consists of a supply and return manifold. The supply manifold includes possibility for individual shut-off of each circuit on flowmeter or shut-off valve. The return manifold is

More information

Solenoid valves Type EVU

Solenoid valves Type EVU Data sheet Solenoid valves EVU EVU solenoid valves are designed to fit into compact refrigeration systems. Available in direct and servo operated versions, they can be applied in liquid, suction, and hot

More information

Pressure operated water valve Type WVFX and WVS

Pressure operated water valve Type WVFX and WVS Data sheet Pressure operated water valve WVFX and WVS Pressure operated water valves types WVFX and WVS are used for regulating the flow of water in refrigeration plants with water-cooled condensers. The

More information

V5000, V5010 Kombi-3-plus BALANCING AND SHUTOFF VALVES

V5000, V5010 Kombi-3-plus BALANCING AND SHUTOFF VALVES V5000 Kombi-3-plus RED V5000, V5010 Kombi-3-plus BALANCING AND SHUTOFF VALVES CONTENTS PRODUCT DATA Overview... 2 Design... 2 Materials... 2 Application... 2 Features... 2 Specifications... 2 Ordering

More information

Condensate Drain Valve AK 45. Original Installation Instructions English

Condensate Drain Valve AK 45. Original Installation Instructions English Condensate Drain Valve AK 45 EN English Original Installation Instructions 810467-03 1 Contents Important Notes Page Usage for the intended purpose...4 Safety note...4 Danger...4 Attention...4 PED (Pressure

More information

Flow controller with integrated control valve (PN 16) AVQM - return and flow mounting

Flow controller with integrated control valve (PN 16) AVQM - return and flow mounting Data sheet Flow controller with integrated control valve (PN 16) AVQM - return and flow mounting Description The controller has a control valve with adjustable flow restrictor, connection neck for electrical

More information

Pressostats and thermostats CAS

Pressostats and thermostats CAS MAKING MODERN LIVING POSSIBLE Technical brochure Pressostats and thermostats CAS www.danfoss.com Description CAS units are pressure-controlled switches. The position of the contacts depends on the pressure

More information

Gauge valves Type SNV-ST and SNV-SS

Gauge valves Type SNV-ST and SNV-SS Data sheet Gauge valves Type and SNV-SS and SNV-SS valves are designed to meet all industrial refrigeration application requirements. Designed as service valves they provide favourable flow characteristics.

More information

Electrically Operated Expansion Valve Types AKV 10, AKV 15 and AKV 20

Electrically Operated Expansion Valve Types AKV 10, AKV 15 and AKV 20 MAKING MODERN LIVING POSSIBLE Data sheet Electrically Operated Expansion Valve Types AKV 10, AKV 15 and AKV 20 AKV are electrically operated expansion valves designed for refrigerating plants. The AKV

More information

V2000Kx KV type TRV Body

V2000Kx KV type TRV Body V2000Kx KV type TRV Body RADIATOR VALVE WITH KV-SPECIALIZED CARTRIDGE PRODUCT DATA Angle to DIN Straight to DIN 011 Application Thermostatic radiator valve bodies (TRV bodies) are fitted on the supply

More information

When ordering, please state type and code number. Suitable sensor length. Max. Cap. range. tube adjust- see also Accessories. sensor. temp.

When ordering, please state type and code number. Suitable sensor length. Max. Cap. range. tube adjust- see also Accessories. sensor. temp. Thermostats Description KPS thermostats are temperature-controlled switches. The position of the contacts depends on the temperature of the sensor and the set value. In this series, special attention has

More information

UNA 13 UNA 15 UNA 15 Stainless Steel Design. Installation Instructions Steam Traps UNA 13, UNA 15

UNA 13 UNA 15 UNA 15 Stainless Steel Design. Installation Instructions Steam Traps UNA 13, UNA 15 UNA 13 UNA 15 UNA 15 Stainless Steel Design Installation Instructions 810604-01 Steam Traps UNA 13, UNA 15 1 Contents Important Notes Page Use... 7 Safety note... 7 Danger... 7 Explanatory Notes Scope

More information

Product Sheet Pre-Fabricated Flushing Bypass Assembly for Plant Applications Hero Plant DN15-150

Product Sheet Pre-Fabricated Flushing Bypass Assembly for Plant Applications Hero Plant DN15-150 Product Sheet Pre-Fabricated Flushing Bypass Assembly for Plant Applications Hero Plant DN15-150 Description Hero Plant is a pre-fabricated, flushing bypass arrangement for balance, control, isolation,

More information

Automatic filter AF 173 G

Automatic filter AF 173 G Automatic filter AF 7 G with external pressure cleaning and integrated cyclone effect Connection sizes: G, screw-in flange DN 0 and DN, cast design Short description MAHLE automatic backflush filters are

More information

Rittal TopTherm Filter Fans

Rittal TopTherm Filter Fans Rittal TopTherm Filter Fans More pressure. Higher air flow rates. 2 Installation without tools Snap-in mounting for easy installation Simple reversal of the air flow direction by turning the fan module

More information

CLA-VAL CPC Position Control 4-20 ma

CLA-VAL CPC Position Control 4-20 ma Position Control 4-20 ma Simple, Reliable & Accurate comm unicatron group IPL group, Slane Road, Drogheda, Co. Louth, Ireland. Tel:+ 353 41 9832591 I Fax:+ 353 41 9832599 I Email: info@ipl.ie I Website:

More information