Valve bodies with pressfit connection and self-sealing tailpiece. Type RA-N for two pipe systems

Size: px
Start display at page:

Download "Valve bodies with pressfit connection and self-sealing tailpiece. Type RA-N for two pipe systems"

Transcription

1 Valve bodies with pressfit connection and self-sealing tailpiece. Type RA-N for two pipe systems EN 215 Application Straight Angle Horizontal angle The valve bodies with pressfit connection are used for heating systems with stainlass steel or copper pipes. The fitting require a commercial compression tool. List of available tools is found on page 2. The valve bodies are physically and technically identical to RA-N, DN15 standard valves. All RA 2000 thermostatic sensors, as well as the new RAX design series, may be used as desired. The RA-N valve bodies with integrated presetting are used in two-pipe pumped heating systems. Flow is adjustable in the range m 3 /h. RA-N valve bodies are supplied with a red protective cap which can be used for manual regulation during the construction phase. The protective cap must not be used as a manual shut off device. A special manual shut off device (code no. 013G5000) should be used. Technical data are according to Euronorm EN 215. The valve bodies are equipped with a self sealing tailpiece featuring an O-ring seal. Valve bodies are manufactured from DZR brass with nickel plating. The pressure pin of the gland seal is of chrominium steel and works in a lifetime lubricated O-ring. The complete gland seal can be replaced without draining down the system. Should water treatment be used it is essential that dosing instructions of the manufacturer are strictly observed. It is recommended that formulations containing mineral oil are avoided. Ordering and data Type Code no. Design RA-N 15 3) 013G G G3239 Angle Straight Horiz. angle Connection Settings, k v values with RA 2000 sensor, m 3 /h 1) mal actuator With ther- Inlet Outlet Xp N N(k vs ) Pressfit R½ Xp= Xp= ) The kv-value indicates the water flow (Q) in m 3 /h at a pressure drop ( p) across the valve of 1 bar; k v = Q: p. The k vs -value states the flow Q at a maximum lift, i.e. at fully open valve at setting N. At setting N the k v -value is stated according to EN 215, at Xp = 2K i.e. the valve is closed at 2 C higher room temperature. At lower settings the Xp value is reduced to 0.5 K of the setting value 1. 2) The maximum differential pressure specified is the maximum pressure at which the valves give satisfactory regulation. As with any device which imposes a pressure drop in the system, noise may occur under certain flow/pressure conditions. To ensure quiet operation, maximum pressure drop should not exceed bar. The differential pressure can be reduced by the use of a Danfoss differential pressure regulator. Accessories Product Code no. Gland seal, may be exchanged with system in operation. O-Ring (5pcs.) 013G G4149 Approvals Danfoss Pressfit valves are tested and approved according to EN 215 (CEN). Pipes compatible with Danfoss pressfit valves are according to EN (welded stainless steel pipes ), EN (Thin-walled carbon steel pipes), EN 1057 (seemless copper pipes) with a minimum wall thickness of 1 mm. The O-rings used in the Danfoss pressfit valves bodies are according to EN 681. DKCD VDUZL402 Danfoss 02/2009 1

2 Presetting Presetting area Reference mark The calculated setting value can be set easily and accurately without using special tools: remove the protective cap or sensor. raise the setting ring. turn the scale on the setting ring until the desired value faces the reference mark, orientated towards the valve outlet. release the setting ring. Factory setting = N. N the valve is completely open. A setting in the shaded area must be avoided. When the sensor is mounted, the presetting is hidden and thus protected against unauthorized alteration. The presetting can be chosen from values between 1 and 7 with intervals of 0.5. At setting Press system Pipes Copper and stainless stell pipes which complies to EN 1057 or EN Steel pipes Outer diametre and pipe weight according to EN 10312, Table 2 for serie 2 steelpipes. Danfoss recommends a pipe weight of min. 1 mm. Carbon steel pipes Tubes in unalloyed steel E195(W.nr ) and E235(W.nr ) according to EN or EN in condition +A or +N. Copper pipes Outer diametre and wall thickness according to EN 1057, Table 3. Danfoss recommends a minimal wall thickness of 1 mm. Pipe hardness min. R 290, meaning that only copper pipes in bars are compatible. No internal reinforcement is required. Compatibility The pressable area of Danfoss Pressfit valves are designed to match a range of commercial press tools and jaws as described in the table. For tools not mentined please check the with the manufacturer. Compatible press tools Press tools and jaws must be used and serviced as described by their manufacturer, and the actual press operation must be inspected. Danfoss require a minimal press force of 30 kn. The actual pressing must not be interrupted and the tool should be locked for removal until the pressing has been completed correctly. The testing of the press points is done according to the manufactures specs. Compatible press tools Geberit Mapress: PWH 75, EFP2, ECO1/ACO1, EFP3, AFP3, ACO 3 REMS: Power-Press E, Power-Press 2000, Power- Press (ACC), Akku-Press (ACC) Rothenberger: ROMAX Pressliner, ROMAX Pressliner ECO, ROMAX AC ECO SANHA: ECO201, ACO201, ACO3, ECO301 Viega: PT3-EH, PT3-AH, Picco, Typ 2 Novopress: AFP 101 RIDGID: CT-400, 320-E Klauke: UAP2, UNP2, UP2EL-14 Compatible press jaws Mapress Geberit: Press jaws15 mm (90532) REMS: V15 (570115), M15 (570110), SA15 (570935) Rothenberger: SV 15 mm (1.5212X), M 15 mm (1.5102X) SANHA: Standard, 15 mm ( , ) Viega: PT2 15mm (Modell , Typ ) Novopress: M 15 RIDGID: ProPress 15 mm (16958) Klauke: KSP3 M15 mm, KSP4 V15 mm With system under pressure all pressfit connections should be inspected. Even if no leakage is seen the connection should be checked. 2 VDUZL402 Danfoss 02/2009 DKCD

3 Fitting DKCD VDUZL402 Danfoss 02/2009 3

4 Capacity Capacities in combination with RA 2000 sensor at P band between 0.5 K and 2K. The P band is the change in room temperature which is required to move the valve from closed position to the position which allows the calculated flow. Sizing example: Required heat: 0.7 kw Cooling across radiator: 20 C. Flow through radiator: Q = x 1.16 = 0.03 m 3 /h = 30 liter/h Pressure drop across valve: p = 1 mwg. Valve setting: 2.5 Alternatively the setting can be read directly in the table "Data and ordering": k v = Q (m 3 /h) p (bar) 4 VDUZL402 Danfoss 02/2009 DKCD

5 Design Materials in contact with water Valve body and other metal parts K v -limiter O-Ring Valve cone Pressure pin and valve spring Nozzle Ms 58, DZR brass PPS EPDM NBR Chrome steel PP The valve bodies are nickle-plated on the outside. 1. Gland seal 2. O-Ring 3. Pressure pin 4. Seal 5. Regulation spring 6. Setting dial 7. Valve body 8. Union nut 9. Nipple 10. Pressfit connection The radiator thermostats consist of the thermostatic elements of the RA 2000/RAX series and the valve body. The element and the valve body are ordered separately. Dimensions 57 ISO 7/1 - R1/ SW24 SW SW Dimensions with RA 2990 or RAX thermostatic sensor. DKCD VDUZL402 Danfoss 02/2009 5

6 6 VDUZL402 Danfoss 02/2009 DKCD

RA-N Valve Bodies with Pressfit Connection and Self-Sealing Tailpiece for Two Pipe Systems

RA-N Valve Bodies with Pressfit Connection and Self-Sealing Tailpiece for Two Pipe Systems Data Sheet RA-N Valve Bodies with Pressfit Connection and Self-Sealing Tailpiece for Two Pipe Systems Application Straight Angle The valve bodies with pressfit connection are used for heating systems with

More information

Lockshield valves with Pressfit connection Type RLV with isulation and regulation

Lockshield valves with Pressfit connection Type RLV with isulation and regulation Data sheet Lockshield valves with Pressfit connection Type RLV with isulation and regulation Application RLV Straight pattern RLV Angle pattern Drain-cock The valve bodies with pressfit connection are

More information

Valve bodies type RA-N with integrated presetting

Valve bodies type RA-N with integrated presetting Data Sheet Application Straight version Angle version Left mounted angle version Horizontal angle version All RA-N valve bodies can be used together with all types of thermostatic elements in the RA 2000

More information

Dynamic Valve Type RA-DV Pressure Independent Radiator Valve

Dynamic Valve Type RA-DV Pressure Independent Radiator Valve Dynamic Valve Type RA-DV Pressure Independent Radiator Valve Application RA-DV straight version RA-DV angle version RA-DV angle Right & Left RA-DV UK (Axial) RA-DV is a series of pressure independent radiator

More information

High capacity valve body, type RA-G

High capacity valve body, type RA-G Application The RA-G valves are fitted with a grey protective cap. This protective cap must not be used as a manual shut off device. A special manual shut off device is available (code no. 013G3300). The

More information

X-tra Collection for designer radiators and bathroom towel rails

X-tra Collection for designer radiators and bathroom towel rails and bathroom towel rails Application The new X-tra Collection is a TRV specially designed for towel rails and designer radiators. Its new and innovative self-sealing ½" valve to radiator connection makes

More information

X-tra Collection for designer radiators and bathroom towel rails

X-tra Collection for designer radiators and bathroom towel rails and bathroom towel rails Application The new X-tra Collection is a TRV specially designed for towel rails and designer radiators. Its new and innovative self-sealing ½" valve to radiator connection makes

More information

High Capacity Valve Body, Type RA-G

High Capacity Valve Body, Type RA-G Data Sheet The RA-G valves are fitted with a grey protective cap. This protective cap must not be used as a manual shut off device. A special manual shut off device is available (code no. 013G3300). Application

More information

Integrated Valve with Presetting for Manifolds in Two-Pipe Heating Systems

Integrated Valve with Presetting for Manifolds in Two-Pipe Heating Systems Data Sheet Integrated Valve with Presetting for Manifolds in Two-Pipe Heating Systems The integrated valve is designed for manifold applications in combination with a system connection piece. Valve and

More information

Integrated Presetting Valves for Normal (013G0380) and Small (013G0381) Volume Flows

Integrated Presetting Valves for Normal (013G0380) and Small (013G0381) Volume Flows Integrated Presetting Valves for Normal (013G0380) and Small (013G0381) Volume Flows Application Integrated valves, type RA-N (013G0380) and RA- U (013G0381), with built-in presetting are designed for

More information

Thermostatic actuator RAVI - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)

Thermostatic actuator RAVI - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) Description RAVI is self-acting thermostatic actuator primarily for use for temperature control of small hot water cylinders - either storage

More information

Integrated Presetting Valves - for Normal Volume Flows RA-N and for Small Volume Flows RA-U

Integrated Presetting Valves - for Normal Volume Flows RA-N and for Small Volume Flows RA-U Integrated Presetting Valves - for Normal Volume Flows RA-N and for Small Volume Flows Application RA-N 013G7382 013G7387 Integrated valves, type RA-N 013G7382 and 013G7387, with built-in presetting are

More information

AVQMT. AVQT controller can be combined with AVT or STM thermostatic actuators.

AVQMT. AVQT controller can be combined with AVT or STM thermostatic actuators. Data sheet Flow and temperature controller with / without integrated control valve (PN 25) AVQT - flow and temperature controller AVQMT - flow and temperature controller with integrated control valve Description

More information

Differential pressure controller with flow limitation and with integrated control valve (PN 16) AHPBM-F flow mounting, fixed setting

Differential pressure controller with flow limitation and with integrated control valve (PN 16) AHPBM-F flow mounting, fixed setting Data sheet Differential pressure controller with flow limitation and with integrated control valve (PN 16) AHPBM-F flow mounting, fixed setting Description The controller has a control valve with adjustable

More information

Temperature controller AVT with safety temperature monitor STM/VG(F) (PN25)

Temperature controller AVT with safety temperature monitor STM/VG(F) (PN25) Data sheet Temperature controller AVT with safety temperature monitor STM/VG(F) (PN25) Description Controller closes on rising temperature. TR1240 The controllers are: Type-tested acc. to EN 14597 and

More information

Combined automatic balancing valve AB-PM valve DN 10-32, PN 16

Combined automatic balancing valve AB-PM valve DN 10-32, PN 16 Data sheet Combined automatic balancing valve AB-PM valve DN 10-32, PN 16 Description AB-PM is a combined automatic balancing valve. It features three function in compact valve body: 1. Differential pressure

More information

Pressure reduction controllers (PN 25) AVDS - for steam AVD - for water

Pressure reduction controllers (PN 25) AVDS - for steam AVD - for water Data sheet Pressure reduction controllers (PN 25) - for steam AVD - for water Description Main data AVD: DN 15-50 k VS 0,4-25 m 3 /h PN 25 Setting range: 1-5 bar / 3-12 bar Temperature: - Circulation water/glycolic

More information

V2000FS FS type TRV Body FINELY PRESETTABLE RADIATOR VALVE WITH FLUSH POSITION

V2000FS FS type TRV Body FINELY PRESETTABLE RADIATOR VALVE WITH FLUSH POSITION V2000FS FS type TRV Body FINELY PRESETTABLE RADIATOR VALVE WITH FLUSH POSITION PRODUCT DATA Application 011 Angle to DIN Angle to NF Straight to DIN Straight to NF Thermostatic radiator valve bodies (TRV

More information

Pressure relief controller AVA (PN 25)

Pressure relief controller AVA (PN 25) Data sheet Pressure relief controller AVA (PN 25) Description AVA is a self-acting pressure relief controller primarily for use in district heating systems. The controller is normally closed and opens

More information

Temperature controller for heating (PN 25) AVT / VG - external thread AVT / VGF - flange

Temperature controller for heating (PN 25) AVT / VG - external thread AVT / VGF - flange Data sheet Temperature controller for heating (PN 25) AVT / VG - external thread AVT / VGF - flange Description AVT / VG AVT / VGF The AVT / VG(F) controller is a self-acting proportional temperature controller

More information

Combined automatic balancing valve AB-PM valve DN 15-25, PN 16

Combined automatic balancing valve AB-PM valve DN 15-25, PN 16 Data sheet Combined automatic balancing valve AB-PM valve DN 15-25, PN 16 Description AB-PM is a combined automatic balancing valve. It features three function in compact valve body: 1. Differential pressure

More information

Flow controller (PN 25) AVQ - return and flow mounting

Flow controller (PN 25) AVQ - return and flow mounting Data sheet Flow controller (PN 5) - return and flow mounting Description is a self-acting flow controller primarily for use in district heating systems. The controller closes when set max. flow is exceeded.

More information

Floor heating system, heating circuit with FHV-A in flow.

Floor heating system, heating circuit with FHV-A in flow. Application FHV control valves are ideally suited for controlling the temperature of individual under-floor heated rooms and for systems using floor-heating in conjunction with radiators. Danfoss offers

More information

Temperature controller (PN 25) AVT / VG - external thread AVT / VGF - flange

Temperature controller (PN 25) AVT / VG - external thread AVT / VGF - flange Data sheet Temperature controller (PN 25) AVT / VG - external thread AVT / VGF - flange Description AVT / VG The AVT / VG(F) controller is a self-acting proportional temperature controller developed primarily

More information

2 - way valve (NO), pressure relieved (PN 25) VG - external thread VGF - flange

2 - way valve (NO), pressure relieved (PN 25) VG - external thread VGF - flange Data sheet 2 - way valve (NO), pressure relieved (PN 25) VG - external thread VGF - flange Description VG and VGF are pressure relieved 2-way normally open (NO) valves, designed to be combined with: -

More information

Flow-compensated temperature controller AVTQ DN 15

Flow-compensated temperature controller AVTQ DN 15 Data sheet Flow-compensated temperature controller AVTQ DN 15 Description AVTQ is a self-acting flow-compensated temperature controller primarily for use in district heating systems with plate heat exchangers

More information

Temperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25)

Temperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25) Data sheet Temperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25) Description Controller closes on rising temperature. The controllers are: - Type-tested acc. to EN 14597

More information

Flow controller (PN 25) AVQ - return and flow mounting

Flow controller (PN 25) AVQ - return and flow mounting Data sheet Flow controller (PN 5) - return and flow mounting Description is a self-acting flow controller primarily for use in district heating systems. The controller closes when set max. flow is exceeded.

More information

FHV control valves are flexible to use, easily installed and are available in two versions:

FHV control valves are flexible to use, easily installed and are available in two versions: FHV-A/FHV-R Application: FHV-A FHV-R The floor-heating valve (FHV) provides an economical method of incorporating a radiant floor heating system into an existing hot water or radiator system. FHV self-acting

More information

Integrated valves Series 3

Integrated valves Series 3 Series 3 Application For decades, Danfoss has been the world s leading manufacturer of radiator valves and radiator thermostats. Danfoss invented the radiator thermostat back in 1943 and later developed

More information

Flow controller with integrated control valve (PN 16) AHQM return and flow mounting

Flow controller with integrated control valve (PN 16) AHQM return and flow mounting Data sheet Flow controller with integrated control valve (PN 16) AHQM return and flow mounting Description DN 15-32 DN 40, 50 DN 50-100 DN 125 DN 150 DN 200, 250 AHQM is a self-acting flow controller with

More information

Flow controller with integrated control valve (PN 16) AHQM - return and flow mounting

Flow controller with integrated control valve (PN 16) AHQM - return and flow mounting Flow controller with integrated control valve (PN 16) AHQM - return and flow mounting Description Controllers are used together with Danfoss electrical actuators: DN 15-32 with - AMV(E) 10 - AMV(E) 13

More information

ASSEMBLY INSTRUCTIONS

ASSEMBLY INSTRUCTIONS ASSEMBLY INSTRUCTIONS. General instructions for installing the pipe. Making a press connection. Making a repair. Making a screw connection. Making a screw/compression connection. Bending the HENCO pipe.

More information

Flow controller with integrated control valve (PN 16) AVQM - return and flow mounting

Flow controller with integrated control valve (PN 16) AVQM - return and flow mounting Data sheet Flow controller with integrated control valve (PN 16) AVQM - return and flow mounting Description The controller has a control valve with adjustable flow restrictor, connection neck for electrical

More information

Data sheet Pressure independent control valve with integrated flow limiter AVQM (PN 16) - return and flow mounting

Data sheet Pressure independent control valve with integrated flow limiter AVQM (PN 16) - return and flow mounting Pressure independent control valve with integrated flow limiter AVQM (PN 16) - return and flow mounting Description Controllers are used together with Danfoss electrical actuators: - AMV 150 1) - AMV(E)

More information

Differential pressure controller (PN 16, 25, 40) AFP(-9) / VFG 2(1) return and flow mounting, adjustable setting

Differential pressure controller (PN 16, 25, 40) AFP(-9) / VFG 2(1) return and flow mounting, adjustable setting Data sheet Differential pressure controller (PN 16, 25, 40) AFP(-9) / VFG 2(1) return and flow mounting, adjustable setting Description The controller has a control valve, an actuator with one control

More information

Pressure independent control valve with integrated flow limiter AVQM (PN 16) - return and flow mounting

Pressure independent control valve with integrated flow limiter AVQM (PN 16) - return and flow mounting Data sheet Pressure independent control valve with integrated flow limiter AVQM (PN 16) - return and flow mounting Description Controllers are used together with Danfoss electrical actuators: AMV 0 1)

More information

V2000BB BB type TRV Body RADIATOR VALVE WITH BROADBAND CARTRIDGE

V2000BB BB type TRV Body RADIATOR VALVE WITH BROADBAND CARTRIDGE V2000BB BB type TRV Body RADIATOR VALVE WITH BROADBAND CARTRIDGE PRODUCT DATA Angle to EN215 (D) 011 Straight to EN215 (D) Application Thermostatic radiator valve bodies (TRV bodies) are fitted on the

More information

Your Personal Catalog Temperature Controllers All our know-how - is now yours

Your Personal Catalog Temperature Controllers All our know-how - is now yours MAKING MODERN LIVING POSSIBLE Your Personal Catalog Temperature Controllers All our know-how - is now yours Index 3 RAVI 12 RAVK 20 RAVV 28 AFT 06/26/17/27 33 AVTB 41 AVTQ DN15 49 AVTQ DN20 57 FJV 61 STFW/VFG(S)

More information

V2000Kx KV type TRV Body

V2000Kx KV type TRV Body V2000Kx KV type TRV Body RADIATOR VALVE WITH KV-SPECIALIZED CARTRIDGE PRODUCT DATA Angle to DIN Straight to DIN 011 Application Thermostatic radiator valve bodies (TRV bodies) are fitted on the supply

More information

Mikrotherm F. Manual Radiator Valves With presetting

Mikrotherm F. Manual Radiator Valves With presetting Mikrotherm F Manual Radiator Valves With presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Mikrotherm F Mikrotherm F The Mikrotherm F manual radiator valve is used in warm water pump heating

More information

Differential pressure relief controller (PN 16, 25, 40) AFPA / VFG 2(1)

Differential pressure relief controller (PN 16, 25, 40) AFPA / VFG 2(1) Data sheet Differential pressure relief controller (, 25, 40) AFPA / VFG 2() Description The controller has a control valve, an actuator with one control diaphragm and spring for differential pressure

More information

Spare parts Pipesystems / Pre-Wall Installation Catalogue 01/2018.

Spare parts Pipesystems / Pre-Wall Installation Catalogue 01/2018. Spare parts Pipesystems / Pre-Wall Installation Catalogue 01/2018 www.friatec.de Informationen Content Product Discount Range Range Page Information 3 Spare parts Piping systems FRIATHERM rigid Bonding

More information

V2000UB UBG type TRV Body RADIATOR VALVE WITH UNLIMITED CARTRIDGE

V2000UB UBG type TRV Body RADIATOR VALVE WITH UNLIMITED CARTRIDGE V2000UB UBG type TRV Body RADIATOR VALVE WITH UNLIMITED CARTRIDGE PRODUCT DATA Application 1/2 011 Thermostatic radiator valve bodies (TRV bodies) are fitted on the supply or return of radiators or heat

More information

Seated valves (PN 16) VRB 2 2-way valve, internal and external thread VRB 3 3-way valve, internal and external thread

Seated valves (PN 16) VRB 2 2-way valve, internal and external thread VRB 3 3-way valve, internal and external thread Data sheet Seated valves (PN 16) VRB 2 2-way valve, internal and external thread VRB 3 3-way valve, internal and external thread Description VRB valves provide a quality, cost effective solution for most

More information

Manual presetting valves LENO MSV-BD

Manual presetting valves LENO MSV-BD Manual presetting valves LENO MSV-BD Description LENO MSV-BD is a range of manual valves for balancing flow in heating, cooling and domestic hot water systems. LENO MSV-BD is a combined presetting and

More information

VZ*19* VZ219E, VZ319E, VZ419E VZ219C, VZ319C, VZ419C

VZ*19* VZ219E, VZ319E, VZ419E VZ219C, VZ319C, VZ419C VZ219E, VZ319E, VZ419E VZ219C, VZ319C, VZ419C SPECIFICATIONS Design PN16, Two-way, Three-way and Three-way with bypass (Linear operation) Function.... Normally Closed (A-AB). [Without actuator fitted]

More information

RTL. Floor Heating Controller Return temperature limiter with and without presetting

RTL. Floor Heating Controller Return temperature limiter with and without presetting RTL Floor Heating Controller Return temperature limiter with and without presetting IMI HEIMEIER / Floor Heating Control / RTL RTL Among other things, the return temperature limiter RTL is used to limit

More information

V2000Kx KV type TRV Body RADIATOR VALVE WITH KV-SPECIALIZED CARTRIDGE

V2000Kx KV type TRV Body RADIATOR VALVE WITH KV-SPECIALIZED CARTRIDGE V2000Kx KV type TRV Body RADIATOR VALVE WITH KV-SPECIALIZED CARTRIDGE PRODUCT DATA 1/2 Angle to DIN 1/2 1/2 Straight to DIN 1/2 011 Application Thermostatic radiator valve bodies (TRV bodies) are fitted

More information

Automatic balancing valves ASV-PV DN (3rd gen.)

Automatic balancing valves ASV-PV DN (3rd gen.) Automatic balancing valves ASV-PV DN 50-100 (3rd gen.) Description / Application Partner valve ASV-PV DN 50 ASV-PV DN 65-100 MSV-F2 DN 50-100 ASV balancing valves are used for dynamic hydronic balance

More information

Thermostatic valve Type AVTA

Thermostatic valve Type AVTA SALES SERVICE +358 (0)17 262 3555 info@econosto.fi MAKING MODERN LIVING POSSIBLE Data sheet Thermostatic valve Type AVTA Thermostatic valves are used for proportional regulation of flow quantity, depending

More information

Regutec F. Return Lockshield Radiator lockshield

Regutec F. Return Lockshield Radiator lockshield Regutec F Return Lockshield Radiator lockshield IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Regutec F Regutec F The Regutec lockshield is used in pumped warm water heating and air conditioning

More information

k VS DN (mm) Connections ( C) (m 3 /h)

k VS DN (mm) Connections ( C) (m 3 /h) Data sheet Differential pressure and flow controller (PN 16, 25, 40) AFPQ / VFQ 2( - return mounting, adjustable setting AFPQ 4 / VFQ 2( - flow mounting, adjustable setting Description The controller has

More information

INT 4/15 Catalogue 2015/2016 We reserve the right to effect changes. System press tools. Piping technology

INT 4/15 Catalogue 2015/2016 We reserve the right to effect changes. System press tools. Piping technology INT 4/5 Catalogue 205/206 We reserve the right to effect changes. Piping technology P For all Viega press systems from d 2 08.0. Viega system press tools can be used with all metallic Viega press systems

More information

VPI45.. VPI45..Q. Combi valves, PN 25. Building Technologies. VPI45..Q with pressure test points ACVATIX

VPI45.. VPI45..Q. Combi valves, PN 25. Building Technologies. VPI45..Q with pressure test points ACVATIX 4 853 VPI45.. VPI45..Q with pressure test points ACVATIX Combi valves, PN 25 for rooms, zones, air handling units as well as small to medium heating, ventilation and air-conditioning systems VPI45.. VPI45..Q

More information

V2880, Therafix Design Thera Design Edition - H-Block with TRV Insert WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS

V2880, Therafix Design Thera Design Edition - H-Block with TRV Insert WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS W GE R MAN Y W GE R MAN Y V2880, Therafix Design Thera Design Edition - H-Block with TRV Insert WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS Design Angle left Straight W GE R MAN Y Angle right The Therafix

More information

4-way Distribution Valve

4-way Distribution Valve 4-way Distribution Valve for one- and two-pipe systems Product specification sheet Application 4-way distribution valves are used to connect supply and return of a radiator to the corresponding pipes of

More information

Pre-Fabricated Flushing Bypass Assembly for Plant Applications Hero Plant DN15-150

Pre-Fabricated Flushing Bypass Assembly for Plant Applications Hero Plant DN15-150 Pre-Fabricated Flushing Bypass Assembly for Plant Applications Description Hero Plant is a pre-fabricated, flushing bypass arrangement for balance, control, isolation, and operation of plant devices. Flow

More information

Thermostatically operated cooling water valves Type AVTA

Thermostatically operated cooling water valves Type AVTA Thermostatically operated cooling water valves Type AVTA Features AVTA Insensitive to dirt Insensitive to water pressure Needs no power supply - self acting Opens on rising sensor temperature Differential

More information

Flow controller (PN 16, 25, 40) AFQ / VFQ 2(1) - return and flow mounting

Flow controller (PN 16, 25, 40) AFQ / VFQ 2(1) - return and flow mounting Data sheet Flow controller (PN 16, 5, 40) AFQ / VFQ ( - return and flow mounting Description The controller has a control valve with adjustable flow restrictor and an actuator with one control diaphragm.

More information

RADIATOR VALVES / RADIATOR VALVES WITH PRESETTING

RADIATOR VALVES / RADIATOR VALVES WITH PRESETTING RAIATOR VAVES / RAIATOR VAVES WITH PRESETTING THERMOSTATIC RAIATOR VAVES WITH PRESETTING Thermostatic radiator valve primary for radiators in heating systems and secondary for small cooling terminals.

More information

Pressure relief controller AFA / VFG 2(1) (PN 16, 25, 40)

Pressure relief controller AFA / VFG 2(1) (PN 16, 25, 40) Data sheet Pressure relief controller AFA / VFG 2(1) (PN 16, 25, 40) Description The controller is a self-acting pressure relief controller primarily for use in district heating systems. The controller

More information

Pressure operated water valve Type WVFX and WVS

Pressure operated water valve Type WVFX and WVS Data sheet Pressure operated water valve WVFX and WVS Pressure operated water valves types WVFX and WVS are used for regulating the flow of water in refrigeration plants with water-cooled condensers. The

More information

VPI45..Q with pressure test points. Combi valves, PN 25

VPI45..Q with pressure test points. Combi valves, PN 25 4 853 VPI45.. VPI45..Q with pressure test points ACVATIX Combi valves, PN 25 for rooms, zones, air handling units as well as small to medium heating, ventilation and air-conditioning systems VPI45.. VPI45..Q

More information

The valves can be controlled electronically by thermal actuators or act as self-acting units by means of remote temperature adjusters.

The valves can be controlled electronically by thermal actuators or act as self-acting units by means of remote temperature adjusters. Floor Heating Manifold FHF Application The Manifold FHF is used for controlling water flow in under floor heating systems. Each tube of the floor heating system is connected to the manifold, thus making

More information

Pressure independent balancing and control valve

Pressure independent balancing and control valve Pressure independent balancing and control valve AB-QM DN 10-150 AB-QM valve equipped with an actuator is a control valve with full authority and automatic balancing function - flow limiter. Typical applications

More information

2-position electric actuators with Ball valves VBZ ½...11/4

2-position electric actuators with Ball valves VBZ ½...11/4 4 831.2 & VBZ ½...11/4 2-position electric actuators with Ball valves VBZ ½ 11/4 90 angle - Unidirectional rotation VBZ ½ 11/4 Electric rotary actuators for two-port ball valves Operating voltage AC 230

More information

VE-S_15-32 Pressure Independent Balancing & Control Valves

VE-S_15-32 Pressure Independent Balancing & Control Valves Page 1 of 9 VE-S_15-32 Pressure Independent Balancing & Control Valves (PIBCV) is used in heating and cooling systems in applications with Fan Coil Units, Chilled Beams or other terminal unit applications.

More information

Combi valves PN 16 with flanged connections

Combi valves PN 16 with flanged connections 4 315 ACVATIX Combi valves PN 16 with flanged connections Pressure Independent Combi Valves VPF43.. With integrated pressure differential controller Valve body made of gray cast iron GJL-250 DN 50, DN

More information

RADIATOR VALVE ACCESSORIES

RADIATOR VALVE ACCESSORIES RADIATOR VALVES ACCESSORIES RADIATOR VALVES CONTENTS Accessories and spare parts: Presetting tools Radiator connections Other connections (FPL, FPL-PX, KOMBI - see each catalogue leaflet) Radiator unions

More information

611, 671. Diaphragm Valve, Metal

611, 671. Diaphragm Valve, Metal Diaphragm Valve, Metal Construction The 611 and 671 manually operated 2/2-way metal diaphragm valves have a low maintenance plastic bonnet and an integral optical position indicator as standard. Features

More information

Technote. Frese OPTIMA Compact DN10-DN50 - pressure independent balancing & control valve. Application. Features. Benefits.

Technote. Frese OPTIMA Compact DN10-DN50 - pressure independent balancing & control valve. Application. Features. Benefits. Page of 5 Frese OPTIMA Compact DN-DN5 Application Frese OPTIMA Compact pressure independent balancing & control valve (PIBCV) is used in heating and cooling systems in applications with Fan Coil Units,

More information

Seated valves (PN 16) VRB 2 2-way valve, internal and external thread VRB 3 3-way valve, internal and external thread

Seated valves (PN 16) VRB 2 2-way valve, internal and external thread VRB 3 3-way valve, internal and external thread Data sheet Seated valves (PN 16) VRB 2 2-way valve, internal and external thread VRB 3 3-way valve, internal and external thread Description Combinations with other actuators could be seen under Accessories.

More information

Manual Presetting Valves LENO MSV-B

Manual Presetting Valves LENO MSV-B Data Sheet Description LENO MSV-B is a new generation of manual valves for balancing flow in heating, cooling and domestic hot water systems. LENO MSV-B is a combined presetting and shut off valve with

More information

Please refer to our catalogue for details of the full product range

Please refer to our catalogue for details of the full product range Thermostatic Radiator Valve Bodies Series V6 - Double Regulating Function ngle Pattern 118 37 63 118 37 64 11.10 11.10 EPDM disk & seals (see note below) F x MU ends Thermostat connection thread M30 x

More information

TRIM, TRIM A, RADITRIM A, TRIM K, STK, TA Loop

TRIM, TRIM A, RADITRIM A, TRIM K, STK, TA Loop TOUR & ANDERSSON AB QUALITY AND ENVIRONMENT SYSTEM Certification of Registration Number 2125 and 2125 M Certified by SP TRIM, TRIM A, RADITRIM A, 1-15-5 TRIM K, STK, TA Loop Return valves and measurement

More information

Tour b Andersson AB THERMOSTATICALLY CONTROLLED RADIATOR VALVE RVT

Tour b Andersson AB THERMOSTATICALLY CONTROLLED RADIATOR VALVE RVT Tour b Andersson AB THERMOSTATICALLY CONTROLLED RADIATOR VALVE RVT The RVT thermostatically controlled radiator valve is intended for use with 2-pipe pump-circulated hot water systems and is very effective

More information

Diaphragm Valve, Metal

Diaphragm Valve, Metal Diaphragm Valve, Metal Construction The GEMÜ pneumatically operated 2/2-way diaphragm valve has a low maintenance membrane actuator which can be controlled by inert gaseous media. Normally Closed, Normally

More information

HENCO TECHNICAL MANUAL 2006

HENCO TECHNICAL MANUAL 2006 HENCO TECHNICAL MANUAL 00 RADIATOR SANITARY GAS Your Connection to Perfection Page PIPES PRESS FITTINGS SCREW FITTINGS MANIFOLDS MANIFOLD CABINETS ASSEMBLY INSTRUCTIONS THE HENCO TS-SYSTEM 0 SPECIFICATIONS

More information

Differential pressure controller AFP / VFG 2 (VFG 21)

Differential pressure controller AFP / VFG 2 (VFG 21) Differential pressure controller AFP / VFG 2 (VFG 21) Description AFP VFG2 (VFG 21) is a self-acting differential pressure controller primarily for use in district heating systems. The controller closes

More information

Angle Seat Control Valve 7020

Angle Seat Control Valve 7020 Angle Seat Control Valve 72 DN 8 up to DN 8 PN 4 Pneumatically operated control valves for neutral through to highly aggressive media. Integrated positioner Compact design All parts contacting the fluid

More information

three-way mixing valve

three-way mixing valve three-way mixing valve with or without presetting, for heating and cooling systems. Pressurisation & Water Quality alancing & Control Thermostatic Control engineering avantage Three-way mixing valve, with

More information

2-Port and 3-Port Zone Valves, PN16

2-Port and 3-Port Zone Valves, PN16 4 867 2-port valves MVI421.15 to MVI421.25 2-Port and 3-Port Zone Valves, P16 3-port valves MXI421.15 to MXI421.25 MVI421... MXI421... Operating voltage C 230 V, 2-position control signal Spring return

More information

Globo P. Ball valves Pump ball valve made of gunmetal

Globo P. Ball valves Pump ball valve made of gunmetal Globo Ball valves ump ball valve made of gunmetal IMI EIMEIER / Shut-off valves / Globo Globo Globo and Globo -S are used in pump warm water heating systems for direct connection to circulating pumps with

More information

611, 671. Diaphragm Valve, Metal

611, 671. Diaphragm Valve, Metal Distributed by: Tel: 905.677.9000 Toll Free: 1.0.486.7863 www.tricanada.com Diaphragm Valve, Metal Construction The 611 and 671 manually operated 2/2-way metal diaphragm valves have a low maintenance plastic

More information

V5000, V5010 Kombi-3-plus BALANCING AND SHUTOFF VALVES

V5000, V5010 Kombi-3-plus BALANCING AND SHUTOFF VALVES V5000 Kombi-3-plus RED V5000, V5010 Kombi-3-plus BALANCING AND SHUTOFF VALVES CONTENTS PRODUCT DATA Overview... 2 Design... 2 Materials... 2 Application... 2 Features... 2 Specifications... 2 Ordering

More information

Assisted lift operated 2/2-way solenoid valves Type EV250B

Assisted lift operated 2/2-way solenoid valves Type EV250B Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way valve program is especially to

More information

HERZ 7217 V. Integral Fixed Orifice Control Valve HERZ 7217 V. Data sheet 7217 V, Issue Size in mm. STRÖMAX Fig No DN L Lm Rp H SW kv kvs

HERZ 7217 V. Integral Fixed Orifice Control Valve HERZ 7217 V. Data sheet 7217 V, Issue Size in mm. STRÖMAX Fig No DN L Lm Rp H SW kv kvs HERZ 7217 V Integral Fixed Orifice Control Valve Data sheet 7217 V, Issue 1011 Size in mm STRÖMAX Fig No DN L Lm Rp H SW kv kvs TS-V LF 1 7217 50 15 83 28,5 1/2 41 27 0,07-0,45 0,48 TS-V MF 1 7217 59 15

More information

Valencia Radiator Valve Range

Valencia Radiator Valve Range Valencia Radiator Valve Range VTL00 VTL0 VHL0 VT00 VT Application PRODUCT DATA SHEET Thermostatic Radiator Valves (TRVs) provide local control of room temperatures to maintain comfort and save energy.

More information

Pressure independent balancing and control valve AB-QM DN

Pressure independent balancing and control valve AB-QM DN Pressure independent balancing and control valve AB-QM DN 10-150 AB-QM valve equipped with an actuator is a control valve with full authority and automatic balancing function - flow limiter. Typical applications

More information

Thermostatic radiator valves with presetting

Thermostatic radiator valves with presetting Thermostatic radiator valves TRV-2, TRV-2S Thermostatic radiator valves with presetting Pressurisation & Water Quality Balancing & Control Thermostatic Control ENGINEERING AVANTAGE Thermostatic radiator

More information

Technote. Frese OPTIMIZER - pressure independent 4-pipe coil control unit. Application. Benefits. Features.

Technote. Frese OPTIMIZER - pressure independent 4-pipe coil control unit. Application. Benefits. Features. Page of 7 Application control unit, in conjunction with the associated hydraulic set provides a complete pressure independent balancing and control group for efficient and effective individual room or

More information

2-Port and 3-Port Zone Valves PN 16

2-Port and 3-Port Zone Valves PN 16 4 842 2-port valves VVI4615 to VVI4625 3-port valves VXI4615 to VXI4625 2-port valves VVS4615 to VVS4625 3-port valves VXS4615 to VXS4625 2-Port and 3-Port Zone Valves PN 16 VVI46 VXI46 VVS46 VXS46 Hot-pressed

More information

Combi valves, PN 25. for rooms, zones, ventilation and air-conditioning systems

Combi valves, PN 25. for rooms, zones, ventilation and air-conditioning systems 4 855 VPP46.. VPI46.. VPP46..Q, with pressure test points P/T VPI46..Q, with pressure test points P/T ACVATIX Combi valves, PN 25 for rooms, zones, ventilation and air-conditioning systems VPP46.. VPP46..Q

More information

3-Port Seat Valves with Male Thread, PN 16

3-Port Seat Valves with Male Thread, PN 16 4 463 3-Port Seat Valves with Male Thread, PN 16 VXG41 Use Media Bronze CC491K (Rg5) valve body DN 15DN 50 k vs 1640 m 3 /h Flat sealing connections with external thread G B to ISO 228/1 Sets of ALG 3

More information

Horizontal Distribution Units - HDU Multi-port

Horizontal Distribution Units - HDU Multi-port Application Danfoss pre-fabricated HDU distribution units are made for distribution and measuring of waterbased heating in 2-pipe horizontal systems. A HDU is easily mounted on the apartment wall and connected

More information

Innovation + Quality. Valves, controls + systems Balancing and Control Valves

Innovation + Quality. Valves, controls + systems Balancing and Control Valves Innovation + Quality Valves, controls + systems Balancing and Control Valves Cocon Q Pressure independent control valve Product specification Size: L1 L2 H1 H2 ½, ½ LF 2.75 3.9 2.0 1.9 ¾ LF 2.9 4.2 2.0

More information

Diaphragm Valve, Metal

Diaphragm Valve, Metal Diaphragm Valve, Metal Construction The GEMÜ pneumatically operated 2/2-way diaphragm valve has a low maintenance actuator. Normally Closed, Normally Open and Double Acting control functions are available.

More information

V Verafix Design Thera Design Edition - Lockshield Valve WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS

V Verafix Design Thera Design Edition - Lockshield Valve WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS V2480 - Verafix Design Thera Design Edition - Lockshield Valve WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS PRODUCT DATA Angle Straight Application The Thera Design Edition is particularly styled for

More information

Angle Seat Valve 7010

Angle Seat Valve 7010 Angle Seat Valve 7 DN 8 up to DN 8 PN 16 - PN Pneumatically operated angle seat valve for the control of neutral, slightly aggressive and highly aggressive media. Compact design Unaffected by lightly contaminated

More information