Valencia Radiator Valve Range
|
|
- Benedict Lamb
- 5 years ago
- Views:
Transcription
1 Valencia Radiator Valve Range VTL00 VTL0 VHL0 VT00 VT Application PRODUCT DATA SHEET Thermostatic Radiator Valves (TRVs) provide local control of room temperatures to maintain comfort and save energy. TRVs sense the air temperature around them and control the flow of water through the radiator to which they are fitted, to maintain and limit the temperature within the room. Air from the room passes over the sensor of the TRV causing the liquid to expand as the temperature rises. The sensor acts onto the valve spindle causing the TRV insert to close. When the temperature falls, the liquid contracts and the spring-loaded valve spindle opens. Only the amount of water required to maintain the room temperature set on the radiator thermostat will flow into the radiator. New research carried out on behalf of TACMA, the Controls Association within BEAMA, shows that, in a typical UK house, heating system energy consumption can be reduced by up to 0% through the installation of TRVs in addition to a Room Thermostat or Programmable Room Thermostat and that installation costs could be recovered within a year. These tests also showed that by providing local temperature control in every room, TRVs can significantly improve comfort for householders by providing better heat distribution around a dwelling, not achieved without TRVs, even if the system is correctly balanced. 0 Features All Valencia TRVs are A Rated for efficiency using liquid sensors to provide consistent and longer lasting performance The TRV head may be mounted vertically or horizontally by swapping the tailpiece and pipe fittings The Valencia Valve bodies are fully compatible with a wide range of other Honeywell TRV heads offering alternative finishes, remote sensor and Vandal resistant versions as well as the Evohome electronic TRV head All Valencia valve bodies allow bi-directional water flow which means that valves can be installed without the need to adjust the insert flow direction after installation Quiet operation Straight and Angled bodies with mm, 0mm or mm compression connections or 0mm Pushfit fittings are available mm play on radiator tailpiece to allow for variation in radiator distance from the valve. The integrated balancing insert allows the system to be balanced and remain balanced when radiator is removed for decorating or replacement. Specification European Standard EN and Keymark approved Suitable for heating water quality to VDI0 VT/VTL0 setting range : C VT00/VTL00 setting range : C TRV Head connection size : M0 x.mm Closing dimension:. mm Stroke:, mm Specific stroke (TRV head): 0. mm/k Maximum Water Temperature: 0 C Maximum Water Pressure: 0 bar Maximum Differential Pressure for reliable and quiet operation:.0 bar DN angle kvs: 0. m/h DN straight kvs: 0. m/h Nominal flow: 0 kg/h Please Note: Heating system water quality should conform with VDI-Guideline 0 Additives must be suitable for EPDM seals The system must be flushed with all valves fully open EN0H-VA0GE R0
2 Design TRV head: Plastic Handwheel (T00 has a chrome plated metal cap) VT00/VTL00 metal-plated chrome or brushed metal finish body variants Nickel or Chrome plated metal connection ring Internal metal liquid filled brass sensor TRV valve: Chrome plated brass angle or straight valve housing PN0 DN Dimensions according EN, appendix A, series GB Integrated (SLBB) balancing insert made of brass with EPDM O-rings, soft seals and stainless steel spindle Plastic decorators cap Chrome plated union nuts and radiator tailpiece Brass compression olives Lockshield valve: Chrome plated brass angle or straight housing PN0 DN Brass insert Plastic protection cap Chrome plated union nuts and radiator tailpiece Brass compression olives EN NOTE: NOTE: All C- and F-values specified at ideal incident flow. This can differ from stated values depending on installation position and air flow. TRV Settings NOTE: Thera-00 (Traditional) with liquid sensor C ( F) C ( F) 0.K 0.K 0.K min. Influence of differential pressure depends on TRV body used. Thera-00 (Classic) with liquid sensor C ( F) C ( F) 0.K 0.K.0K 0 min. EN requirements... C (... F C (0 F) Min. setpoint temperature ( -position) ) Max. setpoint temperature ysteresis nfluence of differential pressure nfluence of heating medium Response time H.0K I.0K I.K 0 min. VT / VTL0 VT00 / VTL00 closed C C C C 0 C C C 0 N/A Values approximate. Heating can freeze when radiator thermostats with zero-position are set at position '0'. Zero-position is also thermostatically controlled - when temperature falls the TRV may open. EN0H-VA0GE R0
3 Classic TRV Dimension, part numbers and descriptions Honeywell Honeywell la a la a a a Part Number H h h h h l la l la l l l la VT00-S 0 VT00-A VTL00-0A VTL00-0A VTL00-A VTL00-A-C VTL00-A-D VTL00-A-P VTL00-A-DP VTL00-0S 0 VTL00-0S 0 VTL00-S 0 VTL00-S-C 0 VTL00-S-D VTL00-S-P 0 VTL00-S-DP Part Number Type Size Pattern Ancillary Parts VT00-S Classic TRV mm Straight VT00-A Classic TRV mm Angled VTL00-0A Classic TRV + Lockshield mm Angled VTL00-0A Classic TRV + Lockshield 0mm Angled VTL00-A Classic TRV + Lockshield mm Angled VTL00-A-C Classic TRV + Lockshield mm Angled Chrome TRV Head VTL00-A-D Classic TRV + Lockshield mm Angled Drain-off tailpiece VTL00-A-P Classic TRV + Lockshield 0mm Pushfit Fittings Angled VTL00-A-DP Classic TRV + Lockshield 0mm Pushfit Fittings Angled Drain-off tailpiece VTL00-0S Classic TRV + Lockshield mm Straight VTL00-0S Classic TRV + Lockshield 0mm Straight VTL00-S Classic TRV + Lockshield mm Straight VTL00-S-C Classic TRV + Lockshield mm Straight Chrome TRV Head VTL00-S-D Classic TRV + Lockshield mm Straight Drain-off tailpiece VTL00-S-P Classic TRV + Lockshield 0mm Pushfit Fittings Straight VTL00-S-DP Classic TRV + Lockshield 0mm Pushfit Fittings Straight Drain-off tailpiece EN0H-VA0GE R0
4 Traditional TRV Dimension, part numbers and descriptions la a la a a a Part Number H h h h h l la l la l l l la VT-S 0 0 VT-A 0 VTL0-0A 0 VTL0-0A 0 VTL0-A 0 VTL0-A-D 0 VTL0-A-P 0 VTL0-A-DP 0 VTL0-0S 0 0 VTL0-0S 0 0 VTL0-S 0 0 VTL0-S-D 0 VTL0-S-P 0 0 VTL0-S-DP 0 Part Number Type Size Pattern Ancillary Parts VT-S Traditional TRV mm Straight VT-A Traditional TRV mm Angled VTL0-0A Traditional TRV + Lockshield mm Angled VTL0-0A Traditional TRV + Lockshield 0mm Angled VTL0-A Traditional TRV + Lockshield mm Angled VTL0-A-D Traditional TRV + Lockshield mm Angled Drain-off tailpiece VTL0-A-P Traditional TRV + Lockshield 0mm Pushfit Fittings Angled VTL0-A-DP Traditional TRV + Lockshield 0mm Pushfit Fittings Angled Drain-off tailpiece VTL0-0S Traditional TRV + Lockshield mm Straight VTL0-0S Traditional TRV + Lockshield 0mm Straight VTL0-S Traditional TRV + Lockshield mm Straight VTL0-S-D Traditional TRV + Lockshield mm Straight Drain-off tailpiece VTL0-S-P Traditional TRV + Lockshield 0mm Pushfit Fittings Straight VTL0-S-DP Traditional TRV + Lockshield 0mm Pushfit Fittings Straight Drain-off tailpiece EN0H-VA0GE R0
5 Traditional TRV - Matching Valve With Manual Operating Cap Dimension, part numbers and descriptions a a a a a a Part Number H h h h h l la l la l l l la VHL0-0A VHL0-0A VHL0-A VHL0-A-D VHL0-A-P VHL0-A-DP VHL0-0S 0 VHL0-0S 0 VHL0-S 0 VHL0-S-D VHL0-S-P 0 VHL0-S-DP Part Number Type Size Pattern Ancillary Parts VHL0-0A Matching Manual Valve mm Angled VHL0-0A Matching Manual Valve 0mm Angled VHL0-A Matching Manual Valve mm Angled VHL0-A-D Matching Manual Valve mm Angled Drain-off tailpiece VHL0-A-P Matching Manual Valve 0mm Pushfit Fittings Angled VHL0-A-DP Matching Manual Valve 0mm Pushfit Fittings Angled Drain-off tailpiece VHL0-0S Matching Manual Valve mm Straight VHL0-0S Matching Manual Valve 0mm Straight VHL0-S Matching Manual Valve mm Straight VHL0-S-D Matching Manual Valve mm Straight Drain-off tailpiece VHL0-S-P Matching Manual Valve 0mm Pushfit Fittings Straight VHL0-S-DP Matching Manual Valve 0mm Pushfit Fittings Straight Drain-off tailpiece EN0H-VA0GE R0
6 Radiator Balancing. SW.. Valves are supplied in the 'fully open' position. To start the Balancing setting, turn the insert dial clockwise until fully closed (mm wrench required) Note : Do not over tighten or damage may result Mark the start position on the brass insert Check the required setting using the chart below and turn the insert dial anti-clockwise until fully the number matches the mark on the insert. Example = setting Example = setting (fully open) max. max. DN angle DN straight INSERT SETTING POSITION. * V = 0 l/h ** p = mbar kv = 0. Insert setting = * given flow rate through radiator ** given differential pressure at radiator EN0H-VA0GE R0
7 Flow Diagram DN Straight 0, Setting kvs Flow Diagram DN Angle 0, Setting kvs Balancing setting Insert setting position = open = kvs kv-value (at p bar, m /h) = open = kvs Balancing setting Insert setting position kv-value (at p bar, m /h) Design flow Design flow P-Band K K K kv-value (at p bar, m /h) P-Band K K K kv-value (at p bar, m /h) Tolerances for Balancing Setting Values Tolerances for Balancing Setting Values % 0% % 0% % 0% % 0% % 0% % 0% Insert setting values Insert setting values EN0H-VA0GE R0
8 Accessories Part Number T00W0GB T0GB TGB TGB TGB HRUK V0-A V0-S Description White Traditional TRV upgrade head. on any VHL0 'Manual' TRV bodies to convert them to a TRV. Classic White / Chrome TRV upgrade head. on any VHL0 'Manual' TRV bodies to convert them to a TRV Classic Polished Chrome TRV upgrade head. on any VHL0 'Manual' TRV bodies to convert them to a TRV Classic Black / Chrome TRV upgrade head. on any VHL0 'Manual' TRV bodies to convert them to a TRV Classic Brushed Chrome TRV upgrade head. on any VHL0 'Manual' TRV bodies to convert them to a TRV White Evohome Electronic TRV upgrade head. on any VHL0 'Manual' TRV bodies to convert them to an electronic TRV Valencia mm Angled / Straight TRV replacement body only (x ) VA00A00 Service tool to clean or replace TRV inserts, without the need to drain down the heating system (x ) VS00SLBB Replacement valve (SLBB) integrated balancing insert (x ) H00-/A Pack of 0x Manual Handwheels TA00A00 White Theft Protection Ring (x ) Honeywell Control Systems Ltd Honeywell House Skimped Hill Lane Bracknell Berkshire RG EB EN0H-VA0GE R0 October 0 0 Honeywell International Inc. Subject to change All rights reserved Manufactured for and on behalf of the Environmental and Combustion Controls Division of Honeywell Technologies Sàrl, Ecublens, Route du Bois, Switzerland or its authorized representative.
V2000FS FS type TRV Body FINELY PRESETTABLE RADIATOR VALVE WITH FLUSH POSITION
V2000FS FS type TRV Body FINELY PRESETTABLE RADIATOR VALVE WITH FLUSH POSITION PRODUCT DATA Application 011 Angle to DIN Angle to NF Straight to DIN Straight to NF Thermostatic radiator valve bodies (TRV
More informationV2000Kx KV type TRV Body
V2000Kx KV type TRV Body RADIATOR VALVE WITH KV-SPECIALIZED CARTRIDGE PRODUCT DATA Angle to DIN Straight to DIN 011 Application Thermostatic radiator valve bodies (TRV bodies) are fitted on the supply
More informationV2000BB BB type TRV Body RADIATOR VALVE WITH BROADBAND CARTRIDGE
V2000BB BB type TRV Body RADIATOR VALVE WITH BROADBAND CARTRIDGE PRODUCT DATA Angle to EN215 (D) 011 Straight to EN215 (D) Application Thermostatic radiator valve bodies (TRV bodies) are fitted on the
More informationV2000UB UBG type TRV Body RADIATOR VALVE WITH UNLIMITED CARTRIDGE
V2000UB UBG type TRV Body RADIATOR VALVE WITH UNLIMITED CARTRIDGE PRODUCT DATA Application 1/2 011 Thermostatic radiator valve bodies (TRV bodies) are fitted on the supply or return of radiators or heat
More informationV2000Kx KV type TRV Body RADIATOR VALVE WITH KV-SPECIALIZED CARTRIDGE
V2000Kx KV type TRV Body RADIATOR VALVE WITH KV-SPECIALIZED CARTRIDGE PRODUCT DATA 1/2 Angle to DIN 1/2 1/2 Straight to DIN 1/2 011 Application Thermostatic radiator valve bodies (TRV bodies) are fitted
More informationV2880, Therafix Design Thera Design Edition - H-Block with TRV Insert WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS
W GE R MAN Y W GE R MAN Y V2880, Therafix Design Thera Design Edition - H-Block with TRV Insert WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS Design Angle left Straight W GE R MAN Y Angle right The Therafix
More informationV Verafix Design Thera Design Edition - Lockshield Valve WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS
V2480 - Verafix Design Thera Design Edition - Lockshield Valve WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS PRODUCT DATA Angle Straight Application The Thera Design Edition is particularly styled for
More informationV5000, V5010 Kombi-3-plus BALANCING AND SHUTOFF VALVES
V5000 Kombi-3-plus RED V5000, V5010 Kombi-3-plus BALANCING AND SHUTOFF VALVES CONTENTS PRODUCT DATA Overview... 2 Design... 2 Materials... 2 Application... 2 Features... 2 Specifications... 2 Ordering
More informationV5032. Kombi-2-plus Manual double regulating balancing valve. Product specification sheet
V503 Kombi--plus Manual double regulating balancing valve Product specification sheet Application The V503 Kombi--plus is a static, variable orifice doubleregulating balancing valve for the return with
More informationRTL. Floor Heating Controller Return temperature limiter with and without presetting
RTL Floor Heating Controller Return temperature limiter with and without presetting IMI HEIMEIER / Floor Heating Control / RTL RTL Among other things, the return temperature limiter RTL is used to limit
More informationV5003F Kombi-VX PRE-SETTABLE FLOW CONTROL VALVE
V5003F Kombi-VX PRE-SETTABLE FLOW CONTROL VALVE PRODUCT DATA 5 4 3 1 7 Application The V5003F Kombi-VX is an automatic balancing valve. It is designed for balancing of heating and cooling systems by providing
More informationPlease refer to our catalogue for details of the full product range
Thermostatic Radiator Valve Bodies Series V6 - Double Regulating Function ngle Pattern 118 37 63 118 37 64 11.10 11.10 EPDM disk & seals (see note below) F x MU ends Thermostat connection thread M30 x
More informationFan-coil valves Series
Fan-coil valves Series 11-11 - 411 Main features Complete range in the following versions : -way - DN: 1/, /4, 1 -way - DN: 1/, /4, 1 -way with 4 ports - DN: 1/, /4 - The -way version and the -way versions
More information4-way Distribution Valve
4-way Distribution Valve for one- and two-pipe systems Product specification sheet Application 4-way distribution valves are used to connect supply and return of a radiator to the corresponding pipes of
More informationX-tra Collection for designer radiators and bathroom towel rails
and bathroom towel rails Application The new X-tra Collection is a TRV specially designed for towel rails and designer radiators. Its new and innovative self-sealing ½" valve to radiator connection makes
More informationMikrotherm F. Manual Radiator Valves With presetting
Mikrotherm F Manual Radiator Valves With presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Mikrotherm F Mikrotherm F The Mikrotherm F manual radiator valve is used in warm water pump heating
More informationAVQMT. AVQT controller can be combined with AVT or STM thermostatic actuators.
Data sheet Flow and temperature controller with / without integrated control valve (PN 25) AVQT - flow and temperature controller AVQMT - flow and temperature controller with integrated control valve Description
More informationACVATIX MiniCombiValves (MCV)
2 185 ACVATIX MiniCombiValves (MCV) Radiator valves featuring integrated differential pressure control for 2-pipe heating systems, fan coils and chilled ceiling systems VPD.. VPE.. Automatic flow limitation
More informationEW130 Series Multijet Water Meters DN15 40 FOR COLD AND WARM POTABLE WATER APPLICATIONS
EW10 Series Multijet Water Meters DN15 0 FOR COLD AND WARM POTABLE WATER APPLICATIONS CONTENTS PRODUCT DATA Fig. 1. EW100BM / EW101BM Contents... 1 General... 2 Application... 2 Features... 2 Design...
More information3-Port Seat Valves with Male Thread, PN 16
6 3-Port Seat Valves with Male Thread, PN 6 VXG ronze CC9K (Rg5) valve body DN 5DN 0 k vs 02525 m 3 /h Flat sealing connections with external thread G to ISO 228/ Sets of ALG 3 screwed fittings with threaded
More informationX-tra Collection for designer radiators and bathroom towel rails
and bathroom towel rails Application The new X-tra Collection is a TRV specially designed for towel rails and designer radiators. Its new and innovative self-sealing ½" valve to radiator connection makes
More informationACVATIX MiniCombiValves (MCV)
2 185 ACVATIX MiniCombiValves (MCV) Radiator valves featuring integrated differential pressure control for 2-pipe heating systems, fan coils and chilled ceiling systems VPD.. VPE.. Automatic flow limitation
More information12415_Pegler_Terrier_8pp_v8 16/1/06 3:06 pm Page 2. Turn on the style... Decorative Radiator Valves
12415_Pegler_Terrier_8pp_v8 16/1/06 3:06 pm Page 2 Turn on the style... Decorative Radiator Valves 12415_Pegler_Terrier_8pp_v8 16/1/06 2:49 pm Page 3 It pays to choose Pegler... Cutting corners on plumbing
More informationThermostatic radiator valves with presetting
Thermostatic radiator valves TRV-2, TRV-2S Thermostatic radiator valves with presetting Pressurisation & Water Quality Balancing & Control Thermostatic Control ENGINEERING AVANTAGE Thermostatic radiator
More informationAngle Pattern Thermostatic Radiator Valve Vertical or horizontal mounting (15mm)
Angle Pattern Thermostatic Radiator Valve Vertical or horizontal mounting (15mm) GENERAL INFORMATION Size Pattern No. Pack 1 Qty Code Barcode 8mmx1/2 Angle Pattern TRV 1 632001 5013866012099 10mmx1/2 Angle
More informationTHERMOSTATIC CONTROL HEADS:
Thermostatic radiator valves for towel warmer style radiators 338 33, 00 series REDITED LEFFI 0009/3 N ISO 900 FM 6 ISO 900 No. 0003 Function onvertible radiator valves are typically used in North merica
More informationV5049A FLANGED LINEAR VALVE PN25/40
V549A FLANGED LINEAR VALVE PN25/4 FEATURES SPECIFICATION DATA Cast iron or cast steel body with flanged end connections Low seat leakage rate Metal-to-metal seating for long life span Self-adjusting packing
More informationHigh capacity valve body, type RA-G
Application The RA-G valves are fitted with a grey protective cap. This protective cap must not be used as a manual shut off device. A special manual shut off device is available (code no. 013G3300). The
More informationVZ*19* VZ219E, VZ319E, VZ419E VZ219C, VZ319C, VZ419C
VZ219E, VZ319E, VZ419E VZ219C, VZ319C, VZ419C SPECIFICATIONS Design PN16, Two-way, Three-way and Three-way with bypass (Linear operation) Function.... Normally Closed (A-AB). [Without actuator fitted]
More informationData sheet Pressure independent control valve with integrated flow limiter AVQM (PN 16) - return and flow mounting
Pressure independent control valve with integrated flow limiter AVQM (PN 16) - return and flow mounting Description Controllers are used together with Danfoss electrical actuators: - AMV 150 1) - AMV(E)
More informationVBGx-xx-xx Externally Threaded Control Ball Valves PN25 (DN40 TO DN50)
VGx-xx-xx Externally Threaded Control all Valves PN25 ( TO DN50) PPLICTION The VG2 2-Way and VG3 3-Way Control all Valves control hot and chilled water with glycol solutions up to 50% according to VDI2035
More informationAutomatic balancing valves ASV-PV DN (3rd gen.)
Automatic balancing valves ASV-PV DN 50-100 (3rd gen.) Description / Application Partner valve ASV-PV DN 50 ASV-PV DN 65-100 MSV-F2 DN 50-100 ASV balancing valves are used for dynamic hydronic balance
More information/
45.900.444-/45.900.446- VENTURI MANIFOLD FOR VK41.5V/VK81.5V GAS CONTROLS PRODUCT HANDBOOK APPLICATION The venturi manifold combined with the VK41.5V/VK81.5V gas controls and a specific DC-fan is called
More informationHigh quality radiators deserve high quality valves for efficient performance and they influence the whole appearance of your finished radiator.
Valves High quality radiators deserve high quality valves for efficient performance and they influence the whole appearance of your finished radiator. Finishes and Colours; A wide range of standard finishes
More informationThree-port slipper valves PN10, female-threaded
4 232 SERIES 02 Three-port slipper valves PN10, female-threaded VBI31.. Three-port slipper valves, PN10, female-threaded Grey cast iron EN-GJL-250 DN 20 40 k vs 6.3...25 m 3 /h Angle of rotation 90 Female-threaded
More informationHS10S-FA. Water station. Product specification sheet
HS10S-FA Water station Product specification sheet Range of Application Medium Drinking water Inlet pressure Max. 16 bar Outlet pressure 1.5-6.5 bar Installation position Horizontal with filter bowl downwards
More informationCombined automatic balancing valve AB-PM valve DN 15-25, PN 16
Data sheet Combined automatic balancing valve AB-PM valve DN 15-25, PN 16 Description AB-PM is a combined automatic balancing valve. It features three function in compact valve body: 1. Differential pressure
More informationHS10S-FA. Water station. Product specification sheet
HS10S-FA Water station Product specification sheet Range of Application Medium Drinking water Inlet pressure Max. 16 bar Outlet pressure 1.5-6.5 bar Installation position Horizontal with filter bowl downwards
More informationCircuit Regulating Valve STRÖMAX GF
Circuit Regulating Valve STRÖMAX - GF Circuit Regulating Valve for differential pressure measurement, with test points, flanged version Data sheet for GF Issue 0 GF STRÖMAX GF with test points H H D L.
More informationCocon QTZ Pressure independent control valve
Technical information Application: The pressure independent control valve with automatic flow control is a valve combination consisting of a flow regulator and a regulating valve. The nominal value of
More informationValve bodies type RA-N with integrated presetting
Data Sheet Application Straight version Angle version Left mounted angle version Horizontal angle version All RA-N valve bodies can be used together with all types of thermostatic elements in the RA 2000
More informationRegutec F. Return Lockshield Radiator lockshield
Regutec F Return Lockshield Radiator lockshield IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Regutec F Regutec F The Regutec lockshield is used in pumped warm water heating and air conditioning
More informationDynamic Valve Type RA-DV Pressure Independent Radiator Valve
Dynamic Valve Type RA-DV Pressure Independent Radiator Valve Application RA-DV straight version RA-DV angle version RA-DV angle Right & Left RA-DV UK (Axial) RA-DV is a series of pressure independent radiator
More informationHERZ 7217 V. Integral Fixed Orifice Control Valve HERZ 7217 V. Data sheet 7217 V, Issue Size in mm. STRÖMAX Fig No DN L Lm Rp H SW kv kvs
HERZ 7217 V Integral Fixed Orifice Control Valve Data sheet 7217 V, Issue 1011 Size in mm STRÖMAX Fig No DN L Lm Rp H SW kv kvs TS-V LF 1 7217 50 15 83 28,5 1/2 41 27 0,07-0,45 0,48 TS-V MF 1 7217 59 15
More informationSOLUTIONS GUIDE. For total efficiency
2014-2015 SOLUTIONS GUIDE For tal efficiency THERMOSTATISABLE, FIXED KV, ANGLE WITH MANUAL HANDWHEEL 808CMJ Left or right mounted angle, M28-head TIP EXAMPLES OF 1-PIPE INSTALLATIONS Standard 1-pipe installation
More informationFloor heating manifold with automatic flow control
dynacon Floor heating manifold with automatic flow control Pressurisation & Water Quality Balancing & Control Thermostatic Control EnGInEERInG advantage dynacon adjusts the flow rate in the individual
More information3-port seat valves, external thread, PN16
4 464 3-port seat valves, external thread, PN6 VXG44.. ronze CC49K (Rg5) valve body DN 5..DN 40 k vs 0.25..25 m 3 /h Flat sealing connections with external thread G to ISO 228- Sets of ALG..3 screwed fittings
More informationEW447-EW452 Series Mechanical Heat Meters FOR HEATING AND COOLING APPLICATIONS
EW447-EW452 Series Mechanical Heat Meters FOR HEATING AND COOLING APPLICATIONS Application PRODUCT DATA Static compact heat meter with electronic measurement, consisting of electronic energy integrator
More informationSeries 02: DN40 and DN50 Series 01: DN Three-port slipper valves PN6
4 241 Series 02: DN40 and DN50 Series 01: DN 65...150 Three-port slipper valves PN6 VBF21.. Three-port slipper valves, PN6, flanged Grey cast iron EN-GJL-250 DN 40...150 k vs 25...820 m 3 /h Angle of rotation
More informationV5825B. Small Linear Valve / PN25 DH Compact Valve. FEATURES Pressure-balanced k vs m 3 /hr Normally-closed valve
V5825B Small Linear Valve / PN25 DH Compact Valve FEATURES Pressurebalanced k vs 1.0...10 m 3 /hr Normallyclosed valve PRODUCT DATA Supplied with manual adjustment cap for startup Small size Threaded and
More informationTemperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25)
Data sheet Temperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25) Description Controller closes on rising temperature. The controllers are: - Type-tested acc. to EN 14597
More informationRADIATOR VALVES / RADIATOR VALVES WITH PRESETTING
RAIATOR VAVES / RAIATOR VAVES WITH PRESETTING THERMOSTATIC RAIATOR VAVES WITH PRESETTING Thermostatic radiator valve primary for radiators in heating systems and secondary for small cooling terminals.
More informationSection 20. HVAC Valves & Products
Section 20 HVAC Valves & Products 0800 276 877 281 Herz Radiator Valves Type DR-T-90 Radiator Control valves with Pre-setting Function. Suitable for Conversion to Thermostatic Operation. Nickel Plated
More informationW Range Solder Ring Fittings
//7 TECH DATA SHEET 49 W Range Solder Ring Fittings Size Pk Pk Code MERCIA W RANGE SOLDER RING FITTINGS GENERAL RANGE Fittings are manufactured from and alloy Available in sizes from 8-4mm Fittings are
More information3-Port Seat Valves with Male Thread, PN 16
4 463 3-Port Seat Valves with Male Thread, PN 16 VXG41 Use Media Bronze CC491K (Rg5) valve body DN 15DN 50 k vs 1640 m 3 /h Flat sealing connections with external thread G B to ISO 228/1 Sets of ALG 3
More informationPressure independent control valve with integrated flow limiter AVQM (PN 16) - return and flow mounting
Data sheet Pressure independent control valve with integrated flow limiter AVQM (PN 16) - return and flow mounting Description Controllers are used together with Danfoss electrical actuators: AMV 0 1)
More informationDirect/Factory Mounting Valve Set
Generated: 29th April 2018 Marflow Hydronics 1 Dimensions DN 15/20 A 243 B 137 C 115 D 3/4 Euroconus d 40 E 30.2 Generated: 29th April 2018 Marflow Hydronics 2 Product Variations NX-EVO-X-X-03 Part No:
More informationProduct Sheet Pre-Fabricated Flushing Bypass Assembly for Terminal Applications Mini-Flush 40
Product Sheet Pre-Fabricated Flushing Bypass Assembly for Terminal Applications Mini-Flush 40 Description Miniflush40 is a pre-fabricated, flushing bypass arrangement for balance, control, isolation, and
More informationHoneywell VV, VP, VB & MS SERIES FOR VQ400M CLASS A VALVES PRODUCT HANDBOOK APPLICATION
Honeywell VV, VP, VB & MS SERIES FOR VQ400M CLASS A VALVES PRODUCT HANDBOOK APPLICATION The VV Series class A vent valves are intended to be used in combination with the VQ400M series combination valve.
More informationFlow controller with integrated control valve (PN 16) AVQM - return and flow mounting
Data sheet Flow controller with integrated control valve (PN 16) AVQM - return and flow mounting Description The controller has a control valve with adjustable flow restrictor, connection neck for electrical
More informationTemperature controller AVT with safety temperature monitor STM/VG(F) (PN25)
Data sheet Temperature controller AVT with safety temperature monitor STM/VG(F) (PN25) Description Controller closes on rising temperature. TR1240 The controllers are: Type-tested acc. to EN 14597 and
More informationInnovation + Quality. Valves, controls + systems Balancing and Control Valves
Innovation + Quality Valves, controls + systems Balancing and Control Valves Cocon Q Pressure independent control valve Product specification Size: L1 L2 H1 H2 ½, ½ LF 2.75 3.9 2.0 1.9 ¾ LF 2.9 4.2 2.0
More informationThermostatically controllable valves art. VD/VS/VCR/VCD/VCS xxxx
Thermostatically controllable valves art. VD/VS/VCR/VCD/VCS xxxx Thermostatically controllable valves have the purpose to cut-off, throttle and regulate flow rate through the heating body, since they are
More informationModulating control valve PN16 with magnetic actuator
Modulating control valve PN with magnetic actuator for hot and chilled water with positioning control and position feedback MP80FY MP00FY Mixing or straight-through valves DN80 and DN00 with magnetic actuator
More informationTemperature controller for heating (PN 25) AVT / VG - external thread AVT / VGF - flange
Data sheet Temperature controller for heating (PN 25) AVT / VG - external thread AVT / VGF - flange Description AVT / VG AVT / VGF The AVT / VG(F) controller is a self-acting proportional temperature controller
More informationFlow controller (PN 25) AVQ - return and flow mounting
Data sheet Flow controller (PN 5) - return and flow mounting Description is a self-acting flow controller primarily for use in district heating systems. The controller closes when set max. flow is exceeded.
More informationFO-BV Series. Fixed-orifice balancing and control valves. Technical Data Sheet. WattsIndustries.com
FO-BV Series Fixed-orifice balancing and control valves Technical Data Sheet WattsIndustries.com Description FO-BV Series fixed-orifice threaded valves are designed for flow control and monitoring in climate
More informationValves. Traditional Valves. Black & Brass TRV. 20 Years Design Choice Service
Valves Every Radiator needs a pair of valves to operate. A good quality valve not only benefits efficient performance they also add to the appearance of your finished radiator. All our valves have a 5
More informationV5050A,B FLANGED LINEAR VALVE PN16 AND PN25/40
V55A,B FLANGED LINEAR VALVE PN16 AND PN25/4 GENERAL These threeport mixing valves are used for modulating control of hot/chilled water or steam in heating, ventilation, and air conditioning systems and
More informationSOLDER RING FITTINGS GENERAL RANGE
Product Guide Size Pk Pk Code SOLDER RING FITTINGS GENERAL RANGE Fittings are manufactured from and alloy Available in sizes from 8-4mm Fittings are designed for jointing tubes to BS EN 7 in hot and cold
More informationCombined automatic balancing valve AB-PM valve DN 10-32, PN 16
Data sheet Combined automatic balancing valve AB-PM valve DN 10-32, PN 16 Description AB-PM is a combined automatic balancing valve. It features three function in compact valve body: 1. Differential pressure
More informationDynacon. Floor Heating Manifolds Floor heating manifold with automatic flow control
Dynacon Automatic Flow Control Floor Heating Manifolds Floor heating manifold with automatic flow control IMI HEIMEIER / Floor Heating Control / Dynacon Dynacon Dynacon adjusts the flow rate in the individual
More informationFlow controller (PN 25) AVQ - return and flow mounting
Data sheet Flow controller (PN 5) - return and flow mounting Description is a self-acting flow controller primarily for use in district heating systems. The controller closes when set max. flow is exceeded.
More informationFLOW CONTROL. PRODUCT GUIDE WATER CONTROLS FOR A MODERN WORLD HEATING SYSTEM COMPONENTS HEATING & COOLING DISTRIBUTION SYSTEMS
www.rwc.co.uk. PRODUCT GUIDE 2018 WATER CONTROLS FOR A MODERN WORLD TEMPERATURE CONTROL FLOW CONTROL HEATING SYSTEM COMPONENTS WASHROOM SYSTEMS HEATING & COOLING DISTRIBUTION SYSTEMS PLUMBING SYSTEMS Flow
More informationElectric Flanged PN16 Cast Iron Ball Valve
Electric actuator direct mounted Type: E4813BS Electric actuator fitted via kit Main J3 Smart electric actuator features: LED light for continual visual actuator status feedback. Fully weatherproof smart
More informationIntegrated Presetting Valves for Normal (013G0380) and Small (013G0381) Volume Flows
Integrated Presetting Valves for Normal (013G0380) and Small (013G0381) Volume Flows Application Integrated valves, type RA-N (013G0380) and RA- U (013G0381), with built-in presetting are designed for
More informationthree-way mixing valve
three-way mixing valve with or without presetting, for heating and cooling systems. Pressurisation & Water Quality alancing & Control Thermostatic Control engineering avantage Three-way mixing valve, with
More informationMT4-024/MT4-230 MT8-024/MT8-230
Smart-T MT4-024/MT4-230 MT8-024/MT8-230 SMLL LINER THERMOELECTRIC CTUTORS PRODUCT DT FETURES No mounting tools required (easily mounted using valve adapter) Water-protected housing design in all mounting
More informationT Series (NPT) 2-Way and 3-Way Terminal Unit Zone Valves 1/2 3/4" 1. Applications. Features. Terminal Unit Zone Valves (NPT)
Terminal Unit Zone Valves (NPT) T Series (NPT) 2-Way and 3-Way Terminal Unit Zone Valves 1/2 3/4" 1 Neptronic 2-way and 3-way terminal unit zone valves are offered in a wide range of styles and connection
More information4017 M HERZ Dimensions in mm
HERZ STRÖMAX 4017 Commissioning valve with integral fixed orifice plate Control valve for chilled and hot water systems in buildings Data sheet for 4017, Issue 0716 Dimensions in mm H2 H1 L1 L2 D 4017
More informationS1024-2POS / S POS S2024-2POS / S POS
GENERAL S0-POS / S00-POS S0-POS / S00-POS SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS 0/0 Nm (88/77 lb-in) FOR -POSITION CONTROL These direct-coupled damper actuators provide two-position control for:
More informationIntegrated Presetting Valves - for Normal Volume Flows RA-N and for Small Volume Flows RA-U
Integrated Presetting Valves - for Normal Volume Flows RA-N and for Small Volume Flows Application RA-N 013G7382 013G7387 Integrated valves, type RA-N 013G7382 and 013G7387, with built-in presetting are
More informationValve bodies with pressfit connection and self-sealing tailpiece. Type RA-N for two pipe systems
Valve bodies with pressfit connection and self-sealing tailpiece. Type RA-N for two pipe systems EN 215 Application Straight Angle Horizontal angle The valve bodies with pressfit connection are used for
More informationV5822A / 5823A,C SMALL LINEAR VALVES PN16 FOR MODULATING AND ON/OFF-CONTROL SPECIFICATIONS GENERAL
V5822 / 5823,C SMLL LINER VLVES PN16 FOR MODULTING ND ON/OFFCONTROL V5822 V5823 SPECIFICTION DT FETURES Small size allows installation where space is limited Range of fittings available for different connections
More information2-port and 3-port terminal unit valves PN16
4 847 2-port valves VVP47..(S) 3-port valves VXP47.. cvatix 2-port and 3-port terminal unit valves PN16 3-port valves with bypass VMP47..(S) VVP47..(S) VXP47.. VMP47..(S) ronze valve body CC491K (Rg5)
More informationTemperature controller (PN 25) AVT / VG - external thread AVT / VGF - flange
Data sheet Temperature controller (PN 25) AVT / VG - external thread AVT / VGF - flange Description AVT / VG The AVT / VG(F) controller is a self-acting proportional temperature controller developed primarily
More informationFloor heating system, heating circuit with FHV-A in flow.
Application FHV control valves are ideally suited for controlling the temperature of individual under-floor heated rooms and for systems using floor-heating in conjunction with radiators. Danfoss offers
More informationValves, controls + systems Cast iron double regulating/ commissioning valves PN 16 Hydrocontrol G
The Oventrop Quality Management System is certified to DIN-EN-ISO 9001 Application: Oventrop double regulating and commissioning valves Hydrocontrol G are installed in the pipework of hot water central
More informationThermostatic actuator RAVI - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)
- for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) Description RAVI is self-acting thermostatic actuator primarily for use for temperature control of small hot water cylinders - either storage
More informationProduct Sheet Pre-Fabricated Flushing Bypass Assembly for Plant Applications Hero Plant DN15-150
Product Sheet Pre-Fabricated Flushing Bypass Assembly for Plant Applications Hero Plant DN15-150 Description Hero Plant is a pre-fabricated, flushing bypass arrangement for balance, control, isolation,
More informationLockshield valves with Pressfit connection Type RLV with isulation and regulation
Data sheet Lockshield valves with Pressfit connection Type RLV with isulation and regulation Application RLV Straight pattern RLV Angle pattern Drain-cock The valve bodies with pressfit connection are
More informationV5832A/5833A,C SMALL LINEAR VALVES PN16 FOR MODULATING AND ON/OFF-CONTROL SPECIFICATIONS
V5832/5833,C SMLL LINER VLVES PN16 FOR MODULTING ND ON/OFFCONTROL V5832 V5833 SPECIFICTION DT FETURES Small size allows installation where space is limited Long stroke results in a high quality characteristic
More informationHERZ-Motorised flow controler
HERZ-Motorised flow controler Control and regulating valve Data sheet 4006 SMART, Issue 0516 Dimensions in mm 4006 M 4006 R M R Order number DN G L L1 B B1 H without Actuator H with Actuator H1 1 4006
More informationPressure independent balancing and control valve
Pressure independent balancing and control valve AB-QM DN 10-150 AB-QM valve equipped with an actuator is a control valve with full authority and automatic balancing function - flow limiter. Typical applications
More informationTechnical information Thermostatic radiator valves
The Oventrop Quality Management System is certified to DIN-EN-ISO 900 Technical information Thermostatic radiator valves Function: Oventrop thermostatic radiator valves are proportional regulators working
More information3-port seat valves PN16 with flanged connection
4 430 Acvatix 3-port seat valves PN16 with flanged connection VXF40.. Grey cast iron EN-GJL-250 valve body DN 15 150 k vs 1.9 315 m 3 /h Can be equipped with SQX.. electromotoric or SKD..-, SK..- and SKC..-
More informationTwo-port seat valves with male thread, PN16
4 363 Two-port seat valves with male thread, PN6 VVG4... Two-port seat valves with male thread, PN6 Bronze Rg5 DN5... DN50 mm (½"... 2") k vs 0.63... 40 m 3 /h Stroke 20 mm Can be equipped with actuators
More informationValves, controllers + systems Double regulating and commissioning valves Hydrocontrol F cast iron, PN 16
Valves, controllers + systems Double regulating and commissioning valves Hydrocontrol F cast iron, PN The Oventrop Quality Management System is certified to DIN-EN-ISO 9001 Technical information Application:
More informationModulating control valve PN16
8 Modulating control valve PN with magnetic actuator for HTHW and steam, with positioning control and position feedback MH...FY...N Control valve with magnetic actuator for modulating control in district
More informationFHV control valves are flexible to use, easily installed and are available in two versions:
FHV-A/FHV-R Application: FHV-A FHV-R The floor-heating valve (FHV) provides an economical method of incorporating a radiant floor heating system into an existing hot water or radiator system. FHV self-acting
More information