Pressure independent control valve with integrated flow limiter AVQM (PN 16) - return and flow mounting
|
|
- Linette Preston
- 6 years ago
- Views:
Transcription
1 Data sheet Pressure independent control valve with integrated flow limiter AVQM (PN 16) - return and flow mounting Description Controllers are used together with Danfoss electrical actuators: AMV 0 1) AMV(E) 10 1) / AMV(E) 20 / AMV(E) 30 AMV(E) 13 1) / AMV(E) 23 / AMV(E) 33 with spring return function AMV 20 SL / AMV 23 SL / AMV 30 SL with stroke limitation 1) AMV 0 can be combined with DN controller only. AVQM combined with AMV(E) 13, AMV(E) 23 (SL) or AMV(E) 33 (SL) has been approved according to DIN AVQM is a self-acting flow controller with integrated control valve developed for the use in district heating / cooling systems. The controller prevents flow to exceed set max flow. In a combination with electrical actuators AMV(E) and ECL electronic controllers the flow and temperature can be controlled to achieve highest energy savings. Main data: DN -32 k VS m 3 /h Flow range m 3 /h PN 16 Differential pressure over control valve Δp MCV 0.2 bar Temperature: Circulation water / glycolic water up to 30 % 2 0 C Connections: Ext. thread (weld-on, thread and flange tailpieces) AVQM has a control valve with adjustable flow limiter, connection neck for electrical actuator and a pressure actuator with one control diaphragm. Ordering AVQM Controller Example: Flow controller with integrated control valvefor flow rate 0.7 m 3 /h; PN 16; T max 0 C; ext. thread - 1 AVQM DN controller Code No: 003H6735 Option: - 1 Weld-on tailpieces Code No: 003H6908 The controller will be delivered completely assembled, inclusive impulse tube between valve and actuator. Electrical actuator AMV(E) must be ordered separately. Picture DN Q max k VS Connection Code No. (mm) (m 3 /h) (m 3 /h) H H G ¾ A 003H H6736 Cylindr. ext. thread acc. to ISO 228 / H G 1 A 003H G 1¼ A 003H G 1¾ A 003H6740 Danfoss VD.DB.V7.02 1
2 Ordering (continuous) Accessories Picture Type designation DN Connection Code No. 003H6908 Weld-on tailpieces H H H6911 R ½ 003H6902 External thread tailpieces 20 Conical ext. thread acc. to R ¾ 003H EN R 1 003H R 1¼ 003H H69 Flange tailpieces 20 Flanges PN 25, acc. to EN H H6917 Service kits Picture Type designation DN k VS (m 3 /h) Code No H H H6863 Valve insert H H on request H H H H6888 Control valve insert H H H H H6795 Type designation Δp setting range (bar) Code No. Actuator H Danfoss VD.DB.V7.02
3 Technical data Valve Nominal diameter DN k VS value of dp controller Range of max. flow setting p MCV = 0.2 bar Q m 3 min /h Q max 2) Available Δp required for Q max bar Stroke mm 5 7 Control valve authority Control characteristic 1 (100%) in the range of flow setting Logarithmic Cavitation factor z Leakage acc. to standard IEC 534 % of k VS Nominal pressure PN 25 Min. differential pressure see remark 1) bar Max. differential pressure 12 Medium Circulation water / glycolic water up to 30 % Medium ph Min. 7, max. 10 Medium temperature ºC 2 0 Connections Materials Valve body valve tailpieces External thread Weld-on and external thread Flange - Red bronze CuSn5ZnPb (Rg5) Valve seat Stainless steel, mat. No Valve cone Sealing DP Sealing MCV Pressure relieve system Dezincing free brass CuZn36Pb2As Control valve insert - Valve insert EPDM Metal Piston Note: DP - diff. pressure controller, MCV - control valve 2) For flows smaller than Q max -> p Actuator Type min Q k VS 2 p Actuator size cm 2 39 Nominal pressure PN 16 Differential pressure over MCV - motorized control valve bar 0.2 Materials MCV AVQM Housing Zinc chromatic steel, DIN 1624, No Diaphragm Impulse tube EPDM Copper tube Ø 6 1 mm Manometric Pressure downstrem [bar] No Cavitation noise T=0 C T=130 C T=80 C Cavitation noise Manometric Pressure upstrem [bar] Cavitation area for cavitation factor z=0.6 VD.DB.V7.02 Danfoss
4 Application principles Return mounting Flow mounting Indirectly connected heating system Indirectly connected heating system Installation positions Media temperature 100 C Media temperature 130 C Media temperature 0 C Electrical actuator Note! Installation positions for electrical actuators AMV(E) have to be observed as well. Please see relevant Data sheet. Pressure temperature diagram PN 16 CuSn5ZnPb (Rg5) PN 16 Maximum allowed operating pressure as a function of medium temperature (according to EN ). 4 Danfoss VD.DB.V7.02
5 Design 1. Control valve insert 2. Adjustable flow restrictor 3. Valve body 4. Valve insert 5. Pressure relieved valve cone 6. Valve stem 7. Built-in spring for flow rate control 8. Control drain 9. Actuator 10. Control diaphragm 11. Union nut 12. Impulse tube 13. Compression fitting for impulse tube 14. Excess pressure safety valve Function Flow volume causes pressure drop across the adjustable flow restrictor. Resulting pressures are being transferred through the impulse tubes and/or control drain in the actuator stem to the actuator chambers and act on control diaphragm for flow control. The flow restrictor diff. pressure is controlled and limited by means of built-in spring for flow control. Control valve closes on rising differential pressure and opens on falling differential pressure to control max flow. Additionally the electrical actuator will operate from zero to set max. flow according to the load. Controller is equipped with excess pressure safety valve, which protects control diaphragm for flow control from too high differential pressure. Settings Max flow limiting Max flow limiting is being done by the adjustment of the flow restrictor position. The adjustment can be performed on the basis of flow adjustment diagram (see relevant instructions) and / or by the means of heat meter. VD.DB.V7.02 Danfoss
6 Dimensions 5 L H 3 H 4 H 2 AMV(E) 2./ 3. + AVQM (DN -32) 277 H H 1 Ø 106 DN AVQM (DN -32) L H H 1 Weight mm (kg) DN H 2 H 3 H 4 mm AMV(E) 10 + AVQM (DN -32) AMV(E) 13 + AVQM (DN -32) AMV 0 + AVQM (DN ) L 3 L 2 L 1 d 2 n d R k SW SW SW 45 DN R 1) SW d L 1 2) L 2 L 3 k d 2 n mm 1/2 32 (G 3/4A) /4 41 (G 1A) (G 11/4A) /4 63 (G 1³/4A) ) Conical ext. thread acc. to EN ) Flanges PN 25, acc. to EN Danfoss VD.DB.V7.02
7 VD.DB.V7.02 Danfoss
8 Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary eady agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved. 8 Danfoss DHS-SRMT/SI VD.DB.V7.02
Data sheet Pressure independent control valve with integrated flow limiter AVQM (PN 16) - return and flow mounting
Pressure independent control valve with integrated flow limiter AVQM (PN 16) - return and flow mounting Description Controllers are used together with Danfoss electrical actuators: - AMV 150 1) - AMV(E)
More informationFlow controller with integrated control valve (PN 16) AVQM - return and flow mounting
Data sheet Flow controller with integrated control valve (PN 16) AVQM - return and flow mounting Description The controller has a control valve with adjustable flow restrictor, connection neck for electrical
More informationFlow controller (PN 25) AVQ - return and flow mounting
Data sheet Flow controller (PN 5) - return and flow mounting Description is a self-acting flow controller primarily for use in district heating systems. The controller closes when set max. flow is exceeded.
More informationPressure relief controller AVA (PN 25)
Data sheet Pressure relief controller AVA (PN 25) Description AVA is a self-acting pressure relief controller primarily for use in district heating systems. The controller is normally closed and opens
More informationFlow controller with integrated control valve (PN 16) AHQM - return and flow mounting
Flow controller with integrated control valve (PN 16) AHQM - return and flow mounting Description Controllers are used together with Danfoss electrical actuators: DN 15-32 with - AMV(E) 10 - AMV(E) 13
More informationPressure reduction controllers (PN 25) AVDS - for steam AVD - for water
Data sheet Pressure reduction controllers (PN 25) - for steam AVD - for water Description Main data AVD: DN 15-50 k VS 0,4-25 m 3 /h PN 25 Setting range: 1-5 bar / 3-12 bar Temperature: - Circulation water/glycolic
More informationFlow controller (PN 25) AVQ - return and flow mounting
Data sheet Flow controller (PN 5) - return and flow mounting Description is a self-acting flow controller primarily for use in district heating systems. The controller closes when set max. flow is exceeded.
More informationDifferential pressure controller with flow limitation and with integrated control valve (PN 16) AHPBM-F flow mounting, fixed setting
Data sheet Differential pressure controller with flow limitation and with integrated control valve (PN 16) AHPBM-F flow mounting, fixed setting Description The controller has a control valve with adjustable
More informationAVQMT. AVQT controller can be combined with AVT or STM thermostatic actuators.
Data sheet Flow and temperature controller with / without integrated control valve (PN 25) AVQT - flow and temperature controller AVQMT - flow and temperature controller with integrated control valve Description
More informationFlow controller with integrated control valve (PN 16) AHQM return and flow mounting
Data sheet Flow controller with integrated control valve (PN 16) AHQM return and flow mounting Description DN 15-32 DN 40, 50 DN 50-100 DN 125 DN 150 DN 200, 250 AHQM is a self-acting flow controller with
More informationPressure relief controller AFA / VFG 2(1) (PN 16, 25, 40)
Data sheet Pressure relief controller AFA / VFG 2(1) (PN 16, 25, 40) Description The controller is a self-acting pressure relief controller primarily for use in district heating systems. The controller
More informationTemperature controller AVT with safety temperature monitor STM/VG(F) (PN25)
Data sheet Temperature controller AVT with safety temperature monitor STM/VG(F) (PN25) Description Controller closes on rising temperature. TR1240 The controllers are: Type-tested acc. to EN 14597 and
More information2 - way valve (NO), pressure relieved (PN 25) VG - external thread VGF - flange
Data sheet 2 - way valve (NO), pressure relieved (PN 25) VG - external thread VGF - flange Description VG and VGF are pressure relieved 2-way normally open (NO) valves, designed to be combined with: -
More informationDifferential pressure controller (PN 16, 25, 40) AFP(-9) / VFG 2(1) return and flow mounting, adjustable setting
Data sheet Differential pressure controller (PN 16, 25, 40) AFP(-9) / VFG 2(1) return and flow mounting, adjustable setting Description The controller has a control valve, an actuator with one control
More informationk VS DN (mm) Connections ( C) (m 3 /h)
Data sheet Differential pressure and flow controller (PN 16, 25, 40) AFPQ / VFQ 2( - return mounting, adjustable setting AFPQ 4 / VFQ 2( - flow mounting, adjustable setting Description The controller has
More informationTemperature controller for heating (PN 25) AVT / VG - external thread AVT / VGF - flange
Data sheet Temperature controller for heating (PN 25) AVT / VG - external thread AVT / VGF - flange Description AVT / VG AVT / VGF The AVT / VG(F) controller is a self-acting proportional temperature controller
More informationTemperature controller (PN 25) AVT / VG - external thread AVT / VGF - flange
Data sheet Temperature controller (PN 25) AVT / VG - external thread AVT / VGF - flange Description AVT / VG The AVT / VG(F) controller is a self-acting proportional temperature controller developed primarily
More informationDifferential pressure relief controller (PN 16, 25, 40) AFPA / VFG 2(1)
Data sheet Differential pressure relief controller (, 25, 40) AFPA / VFG 2() Description The controller has a control valve, an actuator with one control diaphragm and spring for differential pressure
More informationFlow controller (PN 16, 25, 40) AFQ / VFQ 2(1) - return and flow mounting
Data sheet Flow controller (PN 16, 5, 40) AFQ / VFQ ( - return and flow mounting Description The controller has a control valve with adjustable flow restrictor and an actuator with one control diaphragm.
More informationSeated valves (PN 16) VRB 2 2-way valve, internal and external thread VRB 3 3-way valve, internal and external thread
Data sheet Seated valves (PN 16) VRB 2 2-way valve, internal and external thread VRB 3 3-way valve, internal and external thread Description VRB valves provide a quality, cost effective solution for most
More informationFlow-compensated temperature controller AVTQ DN 15
Data sheet Flow-compensated temperature controller AVTQ DN 15 Description AVTQ is a self-acting flow-compensated temperature controller primarily for use in district heating systems with plate heat exchangers
More informationTemperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25)
Data sheet Temperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25) Description Controller closes on rising temperature. The controllers are: - Type-tested acc. to EN 14597
More informationPressure relief controller for oil V22D28 (PN 16, 25)
Data sheet Pressure relief controller for oil V22D28 (PN 16, 25) Description The controller has a control valve, an actuator with one control diaphragm and a spring for pressure setting. Features: - safe
More informationTwo- and three way valves VFG.. / VFGS 2 / VFU.. for self-acting thermostats and electrical actuators
for self-acting thermostats and electrical actuators Description VFG 2 VFG 21 (see pages 2, 3, 4) Valves for heating, district heating and cooling systems. The valves can be used with following actuators:
More informationSeated valves (PN 16) VRB 2 2-way valve, internal and external thread VRB 3 3-way valve, internal and external thread
Data sheet Seated valves (PN 16) VRB 2 2-way valve, internal and external thread VRB 3 3-way valve, internal and external thread Description Combinations with other actuators could be seen under Accessories.
More informationDifferential pressure controller AFP / VFG 2 (VFG 21)
Differential pressure controller AFP / VFG 2 (VFG 21) Description AFP VFG2 (VFG 21) is a self-acting differential pressure controller primarily for use in district heating systems. The controller closes
More informationPressure reduction controller AFD / VFG 2, VFG 21, VFGS 2
Data sheet Pressure reduction controller AFD / VFG 2, VFG 21, VFGS 2 Description The controller is a self-acting pressure reducer primarily for use in district heating systems. The control closes on rising
More informationPressure reduction controller AFD / VFG 2, VFG 21, VFGS 2
Data sheet Pressure reduction controller AFD / VFG 2, VFG 21, VFGS 2 Description The controller is a self-acting pressure reducer primarily for use in district heating systems. The control closes on rising
More informationDifferential pressure relief controller AFPA / VFG 2 (VFG 21)
Differential pressure relief controller AFPA / VFG 2 (VFG 21) Description AFPA VFG2 (VFG 21) is a self-acting differential pressure relief controller primarily for use in district heating systems. The
More informationSeated valves (PN 6) VL 2 2-way valve, flange VL 3 3-way valve, flange
Data sheet Seated valves (PN 6) VL 2 2-way valve, flange VL 3 3-way valve, flange Description VL 2 VL 3 VL 2 and VL 3 valves provide a quality, cost effective solution for most water and chilled applications.
More informationDifferential pressure controller AFP / VFG 2 (VFG 21)
Differential pressure controller AFP / VFG 2 (VFG 21) Description AFP VFG2 (VFG 21) is a self-acting differential pressure controller primarily for use in district heating systems. The controller closes
More informationCombined automatic balancing valve AB-PM valve DN 10-32, PN 16
Data sheet Combined automatic balancing valve AB-PM valve DN 10-32, PN 16 Description AB-PM is a combined automatic balancing valve. It features three function in compact valve body: 1. Differential pressure
More informationFlow Control and Differential Pressure Controller AFPQ / VFQ 2(21) - Installation in return line AFPQ 4 / VFQ 2(21) - Installation in flow line
Flow Control and Differential Pressure Controller AFPQ / VFQ 2(21) - Installation in return line AFPQ 4 / VFQ 2(21) - Installation in flow line Description / Application AFPQ VFQ AFPQ 4 VFQ The controller
More informationDifferential pressure controller AFP / VFG 2 (VFG 21)
Differential pressure controller AFP / VFG 2 (VFG 21) Description / Application AFP VFG2 (VFG 21) is a self-acting differential pressure controller primarily for use in district heating systems. The controller
More informationSeated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange
Data sheet Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange Description VF 2 VF 3 VF 2 and VF 3 valves provide a quality, cost effective solution for most water and chilled applications.
More informationAutomatic balancing valves ASV-PV DN (3rd gen.)
Automatic balancing valves ASV-PV DN 50-100 (3rd gen.) Description / Application Partner valve ASV-PV DN 50 ASV-PV DN 65-100 MSV-F2 DN 50-100 ASV balancing valves are used for dynamic hydronic balance
More informationButterfly valve with electrical actuator VFY-WA
Butterfly valve with electrical actuator Description Position indicator Torque limiter Complete installation from factory - ready for installation Features: Spline driven one piece shaft connected to spherically
More informationButterfly valve with electrical actuator VFY-WA
Butterfly valve with electrical actuator Description Position indicator Torque limiter Complete installation from factory - ready for installation Features: Spline driven one piece shaft connected to spherically
More informationSeated valves (PN 16) VF 2-2-way valve, flange VF 3-3-way valve, flange
Data sheet Seated valves (PN 16) VF 2-2-way valve, flange VF 3-3-way valve, flange Description VF 2 VF 3 VF 2 and VF 3 valves provide a quality, cost effective solution for most water and chilled applications.
More informationON/OFF zone valves AMZ 112, AMZ 113
Data sheet ON/OFF zone valves AMZ 112, AMZ 113 Description The ON/OFF zone valves type AMZ 112 and AMZ 113 are typical used in connection with: Domestic and commercial central heating applications Domestic
More informationServo-operated 2/2-way solenoid valves with isolating diaphragm Type EV222B
Data sheet Servo-operated 2/2-way solenoid valves with isolating diaphragm Type EV222B EV222B is an indirect servo-operated solenoid valve programme for use in connection with contaminated or aggressive
More informationYour Personal Catalog Temperature Controllers All our know-how - is now yours
MAKING MODERN LIVING POSSIBLE Your Personal Catalog Temperature Controllers All our know-how - is now yours Index 3 RAVI 12 RAVK 20 RAVV 28 AFT 06/26/17/27 33 AVTB 41 AVTQ DN15 49 AVTQ DN20 57 FJV 61 STFW/VFG(S)
More informationThermostatic actuator RAVI - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)
- for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) Description RAVI is self-acting thermostatic actuator primarily for use for temperature control of small hot water cylinders - either storage
More informationSeated valves (PN 16) VRG 2 2-way valve, external thread VRG 3 3-way valve, external thread
Data sheet Seated valves (PN 16) 2-way valve, external thread 3-way valve, external thread Description Features: Bubble tight design Snap mechanical connection together with MV(E) 335, MV(E) 435 Dedicated
More informationAssisted lift operated 2/2-way solenoid valves Type EV251B
Data sheet Assisted lift operated 2/2-way solenoid valves Type EV251B EV251B with assisted lift is especially suitable for applications such as closed systems with low and fluctuating pressure conditions
More informationManual presetting valves LENO MSV-BD
Manual presetting valves LENO MSV-BD Description LENO MSV-BD is a range of manual valves for balancing flow in heating, cooling and domestic hot water systems. LENO MSV-BD is a combined presetting and
More informationCombined automatic balancing valve AB-PM valve DN 15-25, PN 16
Data sheet Combined automatic balancing valve AB-PM valve DN 15-25, PN 16 Description AB-PM is a combined automatic balancing valve. It features three function in compact valve body: 1. Differential pressure
More informationPre-Fabricated Flushing Bypass Assembly for Plant Applications Hero Plant DN15-150
Pre-Fabricated Flushing Bypass Assembly for Plant Applications Description Hero Plant is a pre-fabricated, flushing bypass arrangement for balance, control, isolation, and operation of plant devices. Flow
More informationPressure Independent Control Valve AB QM, ½ thru 2 2½ thru 4 5 thru 10 Valve Size
Features and Benefits Danfoss 2016.04 The AB QM temperature control valve provides pressure independent regulation of flow while also providing flow limiting system balance. The valve internally contains
More informationChangeOver6 and NovoCon ChangeOver6 - Motorized 6-port Ball Valves
- Motorized 6-port Ball Valves Description NovoCon The and NovoCon are 6-port motorized ball valves that performs a diverting function between two water circuits in 4-pipe changeover system. This diverting
More informationValve bodies type RA-N with integrated presetting
Data Sheet Application Straight version Angle version Left mounted angle version Horizontal angle version All RA-N valve bodies can be used together with all types of thermostatic elements in the RA 2000
More informationPressure independent balancing and control valve
Pressure independent balancing and control valve AB-QM DN 10-150 AB-QM valve equipped with an actuator is a control valve with full authority and automatic balancing function - flow limiter. Typical applications
More informationSeated valves VF 2, VL 2-2-way VF 3, VL 3-3-way
Data sheet Seated valves VF 2, VL 2-2-way VF 3, VL 3-3-way Description The valves provide a quality, cost effective solution for most water and chilled applications. These valves may be used with glycol
More information3 & 4-Way Rotary Valves
Applications: 3-way Valve 4-way Valve The ESBE 3 and 4-Way rotary valves type F are designed for mixing or diverting applications on heating and cooling systems. The valves are capable of controlling and
More informationHigh Capacity Valve Body, Type RA-G
Data Sheet The RA-G valves are fitted with a grey protective cap. This protective cap must not be used as a manual shut off device. A special manual shut off device is available (code no. 013G3300). Application
More informationSteel butterfly valves SBFV (PN 16/25)
ata sheet Steel butterfly valves SBFV (PN 16/25) escription anfoss SBFV are high performance steel butterfly valves that together with anfoss JIP ball valves complete the family of shut off valves designed
More informationCombined Self-operated Regulators Regulators for Differential Pressure, Flow Rate and Temperature
Combined Self-operated Regulats Regulats f Differential Pressure, Flow Rate and Temperature Application Regulats f district heating supply netwks, heat generats, heat exchangers, building service plants
More informationSeries 46 Self-operated Regulators Differential Pressure and Flow Limiters Type 46-5 Type 46-6
Series 46 Self-operated Regulators Differential Pressure and Flow imiters Type 46-5 Type 46-6 Application Differential pressure and flow limitation for district heating systems with indirect connection,
More informationAV 23 Balancing valves SETTER Inline
AV Balancing valves SETTER Inline Application Direct reading and balancing valve with visual flow indication. Correct balancing of circuits ensure optimum efficiency of the system and can therefore help
More informationSeated valve (PN 16 & PN 25) VFM 2 Two way valve, flange
Data sheet Seated valve (PN 16 & PN 25) VFM 2 Two way valve, flage Descriptio Features: Low seat leakage rate (< 0,03 % of k vs ) Rageability R= >100:1 by PN 16 >100:1 by PN 25 up till DN 125 otherwise
More informationPressure independent balancing and control valve AB-QM DN
Pressure independent balancing and control valve AB-QM DN 10-150 AB-QM valve equipped with an actuator is a control valve with full authority and automatic balancing function - flow limiter. Typical applications
More informationAngle Seat Control Valve 7020
Angle Seat Control Valve 72 DN 8 up to DN 8 PN 4 Pneumatically operated control valves for neutral through to highly aggressive media. Integrated positioner Compact design All parts contacting the fluid
More informationPressure independent balancing and control valve AB-QM DN
Data sheet Pressure independent balancing and control valve AB-QM DN 10-250 The AB-QM valve equipped with an actuator is a control valve with full authority and an automatic balancing function / flow limitation.
More information2, 3 and 4 - way valves VZL
2, 3 and 4 - way valves VZL Description VZL 2 VZL 3 VZL 4 VZL valves provide a high quality, cost effective solution for the control of hot and/or chilled water for fan coil units, small reheaters, and
More informationSeries 240 Pneumatic On-off Valve Type 3351
Series 240 Pneumatic On-off Valve Type 3351 Application Control valve with a tight shutoff of liquids, gases and steam in accordance with DIN or ANSI standards Nominal sizes DN 15 to 100 NPS ½ to 4 Nominal
More informationAngle Seat Valve 7010
Angle Seat Valve 7 DN 8 up to DN 8 PN 16 - PN Pneumatically operated angle seat valve for the control of neutral, slightly aggressive and highly aggressive media. Compact design Unaffected by lightly contaminated
More informationAngle Seat Valve 7010
Angle Seat Valve 7 DN 8 up to DN 8 PN 16 - PN 4 Pneumatically operated angle seat valve for the control of neutral, slightly aggressive and highly aggressive media. Compact design Unaffected by lightly
More informationLet motorized intelligence solve your application challenges
Motorized control valves Let motorized intelligence solve your application challenges For HVAC, central heating, district heating and cooling systems. More than 100,000 Danfoss MVCs have been installed
More informationARI-STEVI 470 / 471 (DN15-150)
With pneumatic and electric actuators ARI-STEVI 470 / 471 (DN15-150) Control valve - straight through with screwed seat ring, shaftguided plug and blow-out protected stem ARI-STEVI 470 / 471 Pneumatic
More informationIntegrated Valve with Presetting for Manifolds in Two-Pipe Heating Systems
Data Sheet Integrated Valve with Presetting for Manifolds in Two-Pipe Heating Systems The integrated valve is designed for manifold applications in combination with a system connection piece. Valve and
More informationRA-N Valve Bodies with Pressfit Connection and Self-Sealing Tailpiece for Two Pipe Systems
Data Sheet RA-N Valve Bodies with Pressfit Connection and Self-Sealing Tailpiece for Two Pipe Systems Application Straight Angle The valve bodies with pressfit connection are used for heating systems with
More informationOperating Guide SBFV (PN16/25) ENGLISH Steel butterfly valve SBFV Page 2. Danfoss VI.IX.A1.02 1
Operating Guide SBFV (PN16/25) ENGLISH Steel butterfly valve SBFV www.danfoss.com Page 2 Danfoss 2016.06 VI.IX.A1.02 1 Table of Contents: 1. OVERVIEW... 3 2. GENERAL... 3 2.1 Safety...3 2.2 Proper use...4
More informationSelf-operated Temperature Regulators Temperature Regulator Type 1u
Self-operated Temperature Regulators Temperature Regulator Type u Application Temperature regulators for cooling installations Control thermostats for set points from 0 to 250 C G ½ to G or DN 5 to DN
More informationV5825B. Small Linear Valve / PN25 DH Compact Valve. FEATURES Pressure-balanced k vs m 3 /hr Normally-closed valve
V5825B Small Linear Valve / PN25 DH Compact Valve FEATURES Pressurebalanced k vs 1.0...10 m 3 /hr Normallyclosed valve PRODUCT DATA Supplied with manual adjustment cap for startup Small size Threaded and
More informationManual Presetting Valves LENO MSV-B
Data Sheet Description LENO MSV-B is a new generation of manual valves for balancing flow in heating, cooling and domestic hot water systems. LENO MSV-B is a combined presetting and shut off valve with
More informationANSI version. The valve closes when the differential pressure rises
Self-operated Regulators Series 42 Differential Pressure Regulator with Type 2424/Type 2428 Actuator and Type 2422 Valve Type 42-24 A Type 42-24 B Type 42-28 A Type 42-28 B ANSI version Application For
More informationTechnote. Frese YDF-2F & YDF-20F - differential pressure control valve. Application. Benefits. Features.
Page 1 of 5 Application Frese YDF-2F and YDF-20F differential pressure control valves are used in central heating-, ventilation-, and district heating systems This model is a high-performing adjustable
More informationTwo-port seat valves with male thread, PN16
4 363 Two-port seat valves with male thread, PN6 VVG4... Two-port seat valves with male thread, PN6 Bronze Rg5 DN5... DN50 mm (½"... 2") k vs 0.63... 40 m 3 /h Stroke 20 mm Can be equipped with actuators
More informationData Sheet T EN
Data Sheet T 8015-1 EN Series 240 Types 3241 1 PSA, -7 PSA, -9 PSA Pneumatic Control Valves Type 3241 PSA Globe Valve Application Control valves for PSA plants (Pressure Swing Adsorption) Valve sizes DN
More information3-Port Seat Valves with Male Thread, PN 16
6 3-Port Seat Valves with Male Thread, PN 6 VXG ronze CC9K (Rg5) valve body DN 5DN 0 k vs 02525 m 3 /h Flat sealing connections with external thread G to ISO 228/ Sets of ALG 3 screwed fittings with threaded
More informationMounting and Operating Instructions EB 5894 EN. Electric control valves with jet pump. Flanged version of valve with jet pump
Electric control valves with jet pump Type 3267/5824, Type 3267/5825, Type 3267/3374, Type 3267/3274 Pneumatic control valves with jet pump Type 3267-1, Type 3267-7 Flanged version of valve with jet pump
More informationExtensions to a comprehensive product range
Extensions to a comprehensive product range As part of our range of motorized control valves you can also find ON/OFF butterfly valves and zone valves applicable for use within heating, ventilation and
More informationPressure relief controller V22 D28
Pressure relief controller V22 D28 For heavy oil and high-viscosity media Instructions for Mounting, Start-up and Maintenance SIBC VI.CB.I1.02 Contents 1. General data Page 1.1 Correct application 1 1.2
More information3-Port Seat Valves with Male Thread, PN 16
4 463 3-Port Seat Valves with Male Thread, PN 16 VXG41 Use Media Bronze CC491K (Rg5) valve body DN 15DN 50 k vs 1640 m 3 /h Flat sealing connections with external thread G B to ISO 228/1 Sets of ALG 3
More informationDA 50. Differential pressure controllers Adjustable set-point
DA 50 Differential pressure controllers Adjustable set-point IMI TA / Differential pressure controllers / DA 50 DA 50 These differential pressure controllers for heating and cooling systems are particularly
More information3-port seat valves, external thread, PN16
4 464 3-port seat valves, external thread, PN6 VXG44.. ronze CC49K (Rg5) valve body DN 5..DN 40 k vs 0.25..25 m 3 /h Flat sealing connections with external thread G to ISO 228- Sets of ALG..3 screwed fittings
More information3/2-Way Valve DN 15 up to DN 40
3/-Way Valve 78 DN up to DN Pneumatically operated 3/-way valve for the control of neutral and slightly aggressive media. (Stainless steel version, Data sheet Type 78) ompact design Unaffected by lightly
More informationManual presetting valve MSV-C
Description / Application MSV-C is used for balancing the flow in cooling, heating and domestic water systems. MSV-C is a combined manual presetting valve with following features: Fixed measurement orifice.
More informationTechnische Dokumentation Technical Documentation
Technische Dokumentation Technical Documentation Fully Lined Sampling Valves XOMOX International GmbH & Co. OHG Dok. Nr.: tdb_sample_gb Von-Behring-Straße 15 D-88131 Lindau / Deutschland Januar 2008 Fully
More informationFor industrial applications For marine applications With proximity switch. Piston type flow switches
JJ For industrial applications JJ For marine applications JJ With proximity switch Piston type flow switches DB_Piston_type_flow_switches 01/2016 199 Piston type flow switches Piston type flow switches
More informationStatic Balancing Valve
Static Balancing Valve Series W-JP45X-16Q Sizes: DN50-DN300 APPLICATION The Series W-JP45X Static Balancing Valve is designed for flow balancing in cooling, heating or process water systems. Its measuring
More informationLined Butterfly Valve Pfeiffer Type BR 10a
Lined Butterfly Valve Pfeiffer Type BR 10a Application Tight closing, double eccentric butterfly valve with PTFE lining for process engineering and plants with industrial requirements, especially suitable
More informationZONE CONTROLE / 2-WAY
ZONE CONTROLE / 2-WAY PRESSURE INDEPENDENT BALANCING AND CONTROL VALVE ON/OFF High-performing and compact, these pressure-independent temperature control valves for variable flow heating and cooling systems,
More information3-port valves vxf42..
Air Comfort Air treatment 99 G.0.0 -port valves vxf.. with flanged connections, pn STAZ- and stz-» eq DATASHEETS -port valves VXf.. In boiler, district heating and refrigeration plants, cooling towers,
More informationControl Valve with integrated positioner
Control Valve 8021 with integrated positioner GS 1 series DN 15 up to DN 150 Pneumatic control valve for the control of neutral through to highly aggressive media in process engineering, chemical industries
More informationRotary Plug Valve BR 23e
PTFE-lined Rotary Plug Valve BR 23e Application: PTFE-lined rotary plug valve for aggressive media, especially due to high demands in chemical plants: Nominal diameter: DN 25, DN 50, DN 80 and NPS1, 2,
More informationSelf-operated Pressure Regulators Type Universal Pressure Reducing Valve
Self-operated Pressure Regulators Type 41-23 Universal Pressure Reducing Valve ANSI version Application Pressure regulators for set points from 0.75 to 400 psi (0.05 to 28 bar) Valves in NPS ½ to 4 (DN
More informationVALFONTA PRESSURE REGULATOR WITHOUT AUXILIARY ENERGY EXCESS PRESSURE VALVE (PRESSURE RELIEF VALVE) MODEL S1 MAIN CHARACTERISTICS
PRESSURE REGULATOR WITHOUT AUXILIARY ENERGY EXCESS PRESSURE VALVE (PRESSURE RELIEF VALVE) MODEL S1 MAIN CHARACTERISTICS The S1 model is self-operated bellows sealed pressure excess valve. This series of
More informationSempell High Pressure Stop Valves Model VA510 (DIN)
Designed for highest pressure and temperature applications using high alloy or stainless steels. Features T-pattern globe type Body made of forged steel Wear resistant stellite body seat Conical seat with
More information2-way and 3-way globe valves
2-way and 3-way globe valves Table of Contents Background Project planning 2 Flow characteristics 2 Principles of flow control 3 ydraulic circuits 4 Design and dimensioning Cavitation diagrams 5 Design
More information