Size: px
Start display at page:

Download "/"

Transcription

1 / VENTURI MANIFOLD FOR VK41.5V/VK81.5V GAS CONTROLS PRODUCT HANDBOOK APPLICATION The venturi manifold combined with the VK41.5V/VK81.5V gas controls and a specific DC-fan is called CVI-vf (Combined Valve Ignition, venturi and fan) and has been specially developed for modulating fully premix appliances. Note: The information of this handbook supplements those of the Product Handbook EN2R-9004 of The Combined Valve and Ignition systems (CVI) and the product handbook EN2R-9017 of the V5306V integrated 1:1 gas/air regulator The information of this handbook specifies the today supplementary features and data but also limitations on models and specifications of the CVI Gas Control with the / venturi manifold. Subject to change without notice. All rights reserved. General Contents Description... 2 Features... 2 Technical Specifications... 3 Dimensional drawing... 4 Dimensional drawing venturi manifold... 5 Adjustments and Checkout... 6 Various Standards and approvals... 6 Application notes... 6 Ordering information... 7 Accessories EN2R R13-NE

2 DESCRIPTION The venturi manifold is a gas/air mixing unit that allows modulation of a premix burner with constant gas/air ratio down to 20% of maximum load. It is to be used in combination with a fan and a Honeywell 1:1 regulating gas valve. The modulation is accomplished by changing the fan speed. The outlet pressure of the gas valve is regulated to ambient pressure by the gas valve. The venturi generates a negative pressure against ambient by which the gas is drawn through the gas valve outlet. The venturi manifold system is designed to be fitted in up to eight positions on a specially adapted DC fan, using two supplied M5 thread forming screws. The venturi manifold is sealed with a gasket that is supplied with the assembly. The gas valve can be fitted directly on the manifold assembly in horizontal and vertical position with both the side outlet and the end outlet. Four M4 screws and a special NBR gasket are used for the end outlet version. Three M5 screws and a special sealing ring are used for the side outlet version. The venturi manifold can be trimmed to the correct gas/air ratio by turning the throttle screw FEATURES The following features are deviating from Product handbook VK41../VK81.. series (EN2R-9004) General In combination with CVI, all burner control and safety functions are concentrated in one optimised system (function integration) All adjustments and test points from one (top) side accessible. Wide modulation band ( % boiler load) or lower fan speed at normal modulation band ( % boiler load) are possible. Flexible mounting positions of gas control to venturi housing and venturi housing to fan. Built in throttle function (venturi manifold) for adjustment on gas type. Options LP gas models with integrated injection orifice. EN2R R13-NE 2

3 SPECIFICATIONS Model Code 1) Inlet and outlet code 2) Reference load 3) x kw x kw x kw x50 *) kw x kw x kw x kw x kw 1 )x = 0: with gasket and screws x = 2: without gasket and screws 2 ) The inlet and outlet codes are visible on the top and bottom plastic parts. 3 ) The reference load is the gross boiler load at which the venturi has an overall pressure drop of 450 Pa Dimensions See Dimensional drawing on page 4 Ambient temperature C Gas valve connection A flange connection set is required to mount the manifold assembly onto the gas valve. (See Accessories on page 8) Minimum load The minimum load for which the unit can be used is 20% of the reference load, which equals a minimum pressure differential of 50 Pa of the 1:1 gas control. Throttle range With the throttle an air factor of 1.3 is adjustable in the H, L and LL-band of natural gas. Material Housing: ZnAl4Cu1 (Z410, Zamac Z5) Venturi: statically dissipative POM Throttle screw: brass Fan plate gasket: cork nitrile rubber Seals: rubber (NBR) Pressure drop 450 Pa maximum at reference load. (Overall pressure drop of the venturi) Venturi pressure 1250 Pa minimum at reference load. (The venturi pressure is the determination of the effective gas pressure) Tracking inaccuracy (not applicable for inlet and outlet code 050 * ) The tracking inaccuracy is the deviation from a constant gas/ air ratio over the modulation band % Typical: 10% without internal injection orifice. 5% with internal injection orifice. Code x55: 15% without internal injection orifice. 7.5% with internal injection orifice. *) Only suitable in specially adapted applications 3 EN2R R13-NE

4 DIMENSIONAL DRAWING 60 G.126/RG130 Air inlet Gas inlet CVI R1 EN2R R13-NE 4

5 DIMENSIONAL DRAWING VENTURI MANIFOLD R38 Screw M5 thread forming at R '(2x) R48 Ø (2) EN2R R13-NE

6 ADJUSTMENTS AND CHECKOUT Adjustment Check gas input to the appliance using a pressure gauge (resolution of 1 Pa (0.01 mbar) or better) connected to the outlet pressure tap. Put CO 2 meter probe (inaccuracy < 0.1%) into exhaust gas outlet. Screw throttle adjustment screw approx. half way down (about 10 mm turned down). ❶ Start appliance ❷ Run appliance at maximum load. ❸ Observe CO 2 meter and adjust throttle screw until CO 2 percentage is at nominal value.turn throttle screw clockwise to reduce gas flow and CO 2 percentage ❹ If appliance does not start, turn throttle screw three turns counter clockwise and repeat starting procedure. ❺ Keep appliance running until completely stabilised, accurate adjustment when necessary. ❻ Set appliance to minimum load. ❼ Check offset pressure according to the manufacturer s instructions. Repeat from 1 to 6 inclusive when adjustment of offset pressure was necessary. After adjustments are made, stop appliance, disconnect pressure gauge and CO 2 meter and tighten outlet pressure tap. Final checkout of the installation After any adjustment, set appliance in operation. Observe several complete cycles to ensure that all burner components function correctly. STANDARDS AND APPROVALS The venturi manifold is not certified separately. It will be certified as part of the appliance. APPLICATION NOTES Make sure the venturi inlet is not obstructed. This will influence the air factor. If the distance from another boiler component to the venturi inlet is more than 50 mm, air factor and boiler load are not influenced. There is a strong interaction between the venturi, gas control and burner. For this reason it is important to fit the characteristics of these components to each other. If not matched well, for instance acoustic problems could be generated. It is recommended to test the appliance at both cold start and hot start conditions with high and low caloric test gases. EN2R R13-NE 6

7 ORDERING INFORMATION When ordering specify: Order number of venturi manifold required: see table below. Ordering Specification Reference load number kw kw kw ) 56 kw ) 40 kw ) 27 kw )* 82 kw ) 72 kw ) 46 kw ) 34 kw 1) without gasket and screws. * only suitable in specially adapted applications. Model number of VK41.5V/VK81.5V gas control. The fan should be obtained from the fan manufacturer: G.126 of EBM or RG130 from MVL. Order numbers of replacement parts and accessories required: See Accessories on page 8. Note: Most models of valves, replacement parts and accessories will be available under TRADELINE label. Ask your wholesaler for details. 7 EN2R R13-NE

8 ACCESSORIES Accessories for VK41.5/VK81.5V series gas controls Description Packing quantity Ordernumber Sealing ring and screws for mounting onto side outlet Gasket and screws for mounting onto end outlet Sealing ring for mounting onto side outlet Gasket for mounting onto fan Gasket for mounting onto fan Screws for mounting fan onto venturi Orifice for LPG application Code venturi Orifice dia (mm) Packing quantity Order number x x x x x x x Manufactered for and on behalf of the Environmental and Combustion Controls Division of Honeywell Sàrl, Ecublens, Route du Bois 37, Switzerland by its Autorized Representative: Automation and Control Solutions Combustion Controls Europe Honeywell BV Phileas Foggstraat AJ Emmen The Netherlands Tel.: +31 (-) Fax: +31 (-) EN2R R13-NE 8

VE4000 & VE5000 SERIES

VE4000 & VE5000 SERIES VE4000 & VE5000 SERIES CLASS "A" GAS VALVES PRODUCT HANDBOOK APPLICATION These series class A gas valves are used for control and regulation of gaseous fluids in gas power burners, atmospheric gas boilers,

More information

Honeywell VV, VP, VB & MS SERIES FOR VQ400M CLASS A VALVES PRODUCT HANDBOOK APPLICATION

Honeywell VV, VP, VB & MS SERIES FOR VQ400M CLASS A VALVES PRODUCT HANDBOOK APPLICATION Honeywell VV, VP, VB & MS SERIES FOR VQ400M CLASS A VALVES PRODUCT HANDBOOK APPLICATION The VV Series class A vent valves are intended to be used in combination with the VQ400M series combination valve.

More information

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION VQ400M SERIES PRODUCT HANDBOOK APPLICATION The VQ400M Series class A safety combination valves are used for control and regulation of gaseous fluids in gas power burners, atmospheric gas boilers, melting

More information

VR400/VR800 series UNIVERSAL GAS VALVES CLASS A SERVO REGULATED COMBINATION VALVES APPLICATION. Contents PRODUCT HANDBOOK. General

VR400/VR800 series UNIVERSAL GAS VALVES CLASS A SERVO REGULATED COMBINATION VALVES APPLICATION. Contents PRODUCT HANDBOOK. General UNIVERSAL GAS VALVES VR00/VR800 series CLASS A SERVO REGULATED COMBINATION VALVES APPLICATION PRODUCT HANDBOOK The VR00 Series class A servo regulated combination valves are used for control and regulation

More information

VE Series. Class "A" Gas Valves. Product handbook APPLICATION CONTENTS. General. Technical. Installation and operation. Various

VE Series. Class A Gas Valves. Product handbook APPLICATION CONTENTS. General. Technical. Installation and operation. Various Class "A" Gas Valves Product handbook APPLICATION These series class A gas valves are used for control and regulation of gaseous fluids in gas power burners, atmospheric gas boilers, melting furnaces,

More information

S4562C 1085 COMBI BOARD APPLICATION. Contents PRODUCT HANDBOOK. General

S4562C 1085 COMBI BOARD APPLICATION. Contents PRODUCT HANDBOOK. General S4562C 1085 COMBI BOARD APPLICATION PRODUCT HANDBOOK The S4562C 1085 combi board is an integration of an on/off temperature control and an electronic ignition control. The S4562C 1085 combi board is intended

More information

AQUASTATS THERMOSTAT APPLICATION

AQUASTATS THERMOSTAT APPLICATION AQUASTATS THERMOSTAT APPLICATION PRODUCT HANDBOOK The L41../L61.. series aquastats are primarily designed for application on water filled heating systems and systems for hot water supply, mainly domestic

More information

822 NOVAMIX GAS FLOW RATE ADJUSTMENT AS A FUNCTION OF THE AIR FLOW GAS/AIR RATIO 1:1 DOUBLE AUTOMATIC SOLENOID SHUT-OFF VALVE

822 NOVAMIX GAS FLOW RATE ADJUSTMENT AS A FUNCTION OF THE AIR FLOW GAS/AIR RATIO 1:1 DOUBLE AUTOMATIC SOLENOID SHUT-OFF VALVE SIT Group 822 NOVAMIX MULTIFUNCTIONAL GAS CONTROL GAS FLOW RATE ADJUSTMENT AS A FUNCTION OF THE AIR FLOW GAS/AIR RATIO 1:1 DOUBLE AUTOMATIC SOLENOID SHUT-OFF VALVE SERVO-CONTROLLED PRESSURE REGULATOR PIN

More information

V5049A FLANGED LINEAR VALVE PN25/40

V5049A FLANGED LINEAR VALVE PN25/40 V549A FLANGED LINEAR VALVE PN25/4 FEATURES SPECIFICATION DATA Cast iron or cast steel body with flanged end connections Low seat leakage rate Metal-to-metal seating for long life span Self-adjusting packing

More information

LKS 160 FOR AIR DAMPERS ON MULTI-STAGE AND MODULATING BURNERS

LKS 160 FOR AIR DAMPERS ON MULTI-STAGE AND MODULATING BURNERS ACTUATOR LKS 160 FOR AIR DAMPERS ON MULTI-STAGE AND MODULATING BURNERS PRODUCT HANDBOOK APPLICATION The LKS 160 air damper actuator is designed to be fitted to multi-stage or modulating oil and gas burners

More information

Eclipse RatioAir Burners

Eclipse RatioAir Burners Parameter Maximum Input, BTU/hr (kw) 1, Minimum Input, BTU/hr (kw) Lower inputs may be achieved. Contact factory. Main Gas Inlet Pressure, "w.c. (mbar) 3 Fuel pressure at ratio regulator inlet. High Fire

More information

GV30 / GV30A SERIES GAS COMBINATION CONTROL SYSTEMS FOR COMMERCIAL COOKING APPLIANCES.

GV30 / GV30A SERIES GAS COMBINATION CONTROL SYSTEMS FOR COMMERCIAL COOKING APPLIANCES. GV0 / GV0A SERIES GAS COMBINATION CONTROL SYSTEMS FOR COMMERCIAL COOKING APPLIANCES R www.mertikmaxitrol.com CONTENT GENERAL INFORMATION GV0 AND GV0A STANDARD FEATURES OPTIONAL TEMPERATURE KNOBS AND D-STEMS

More information

EW447-EW452 Series Mechanical Heat Meters FOR HEATING AND COOLING APPLICATIONS

EW447-EW452 Series Mechanical Heat Meters FOR HEATING AND COOLING APPLICATIONS EW447-EW452 Series Mechanical Heat Meters FOR HEATING AND COOLING APPLICATIONS Application PRODUCT DATA Static compact heat meter with electronic measurement, consisting of electronic energy integrator

More information

RS/1 SERIES. One Stage Gas Burners RS 34/1 MZ RS 44/1 MZ kw kw GAS

RS/1 SERIES. One Stage Gas Burners RS 34/1 MZ RS 44/1 MZ kw kw GAS The RS/1 series of burners covers a firing range from 70 to 550 kw, and they have been designed for use in low or medium temperature hot water boilers, hot air or steam boilers, diathermic oil boilers.

More information

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION VQ400M SERIES PRODUCT HANDBOOK APPLICATION The VQ400M Series class A safety combination valves are used for control and regulation of gaseous fluids in gas power burners, atmospheric gas boilers, melting

More information

VICTRIX PRO Wall-hung modular condensing boiler for heating only

VICTRIX PRO Wall-hung modular condensing boiler for heating only PRO Wall-hung modular condensing boiler for heating only Wide range (5 models) High efficiency and low pollutant emissions thanks to condensing technology Modulating heat output from 10 to 100% Possible

More information

Valencia Radiator Valve Range

Valencia Radiator Valve Range Valencia Radiator Valve Range VTL00 VTL0 VHL0 VT00 VT Application PRODUCT DATA SHEET Thermostatic Radiator Valves (TRVs) provide local control of room temperatures to maintain comfort and save energy.

More information

S1024-2POS / S POS S2024-2POS / S POS

S1024-2POS / S POS S2024-2POS / S POS GENERAL S0-POS / S00-POS S0-POS / S00-POS SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS 0/0 Nm (88/77 lb-in) FOR -POSITION CONTROL These direct-coupled damper actuators provide two-position control for:

More information

2-port ball valves with flanged connection, PN25

2-port ball valves with flanged connection, PN25 s 4 120 ACVATIX 2-port ball valves with flanged connection, PN25 VAF51.. Gray cast iron EN-GJL-250 (HT250) valve body DN 65...150 k vs 63...360 m 3 /h Angle of rotation 90 Flange connection to ISO 7005-2

More information

V5050A,B FLANGED LINEAR VALVE PN16 AND PN25/40

V5050A,B FLANGED LINEAR VALVE PN16 AND PN25/40 V55A,B FLANGED LINEAR VALVE PN16 AND PN25/4 GENERAL These threeport mixing valves are used for modulating control of hot/chilled water or steam in heating, ventilation, and air conditioning systems and

More information

RS SERIES. Two Stage Progressive Gas Burners FIRING RATES

RS SERIES. Two Stage Progressive Gas Burners FIRING RATES The RS burners series covers a firing range from 44 to 2290 kw, and it has been designed for use in low or medium temperature hot water boilers, hot air or steam boilers, diathermic oil boilers. Operation

More information

P95H Regulator Applications P95H Part Matrix Specifi cations Materials of Construction P95H Flow Coeffi cients Wide Open Coeffi cients

P95H Regulator Applications P95H Part Matrix Specifi cations Materials of Construction P95H Flow Coeffi cients Wide Open Coeffi cients PH Regulator Large Capacity Working Media Include ir, Steam and Liquids ll Vents are Tapped The PH is a direct operating pressure reducing regulator with large capacity. Ideally suited for uses in oil

More information

available in battery up to 4 units for a total of 560 kw

available in battery up to 4 units for a total of 560 kw MODULATING CONDENSING BOILER with double premix low NOx burner and double heat exchanger EXPANDABLE IN BATTERY for indoor and outdoor installations (IPX5D) OUTPUT RANGE from 10 to 560 kw (in battery) WORKING

More information

V5197A Firing Rate Gas Valve

V5197A Firing Rate Gas Valve V5197A Firing Rate Gas Valve FEATURES PRODUCT DATA APPLICATION The V5197A is a firing rate valve used to provide variable flow control of air, natural gas, liquefied petroleum (LP), and manufactured gases.

More information

LKS 170 FOR AIR DAMPERS ON SINGLE, DUAL STAGE AND MODULATING BURNERS

LKS 170 FOR AIR DAMPERS ON SINGLE, DUAL STAGE AND MODULATING BURNERS ACTUATOR LKS 170 FOR AIR DAMPERS ON SINGLE, DUAL STAGE AND MODULATING BURNERS PRODUCT HANDBOOK APPLICATION The LKS 170 air damper actuator is designed to be fitted to multi-stage or modulating oil and

More information

FO-BV Series. Fixed-orifice balancing and control valves. Technical Data Sheet. WattsIndustries.com

FO-BV Series. Fixed-orifice balancing and control valves. Technical Data Sheet. WattsIndustries.com FO-BV Series Fixed-orifice balancing and control valves Technical Data Sheet WattsIndustries.com Description FO-BV Series fixed-orifice threaded valves are designed for flow control and monitoring in climate

More information

VQ400M SERIES CLASS A COMBINATION VALVES INSTRUCTION SHEET APPLICATION

VQ400M SERIES CLASS A COMBINATION VALVES INSTRUCTION SHEET APPLICATION VQ400M SERIES INSTRUCTION SHEET APPLICATION The VQ400M Series class A safety combination valves are used for control and regulation of gaseous fluids in gas power burners, atmospheric gas boilers, melting

More information

CHALLENGER Propane to Natural Gas Instructions

CHALLENGER Propane to Natural Gas Instructions Kit Part Number: CCRKIT02 Kit Includes: - Rating Label - (3) Natural Gas Orifices - T-15 Torx Wrench Recommended Tools: - Phillips-Head Screwdriver - Standard Adjustable Wrenches - Calibrated Combustion

More information

CODE MODEL TYPE G3BF 490T G5BF 492T G5BF 489T53

CODE MODEL TYPE G3BF 490T G5BF 492T G5BF 489T53 Installation, use and maintenance instructions Kerosene burners One stage operation CODE MODEL TYPE 3749053 G3BF 490T53 374957 G5BF 49T57 3748953 G5BF 489T53 9036 (6) TECHNICAL FEATURES TYPE - Boiler

More information

HS10S-FA. Water station. Product specification sheet

HS10S-FA. Water station. Product specification sheet HS10S-FA Water station Product specification sheet Range of Application Medium Drinking water Inlet pressure Max. 16 bar Outlet pressure 1.5-6.5 bar Installation position Horizontal with filter bowl downwards

More information

Pressure regulator with solenoid valve VAD Air/gas ratio control with solenoid valve VAG Variable air/gas ratio control with solenoid valve VAV

Pressure regulator with solenoid valve VAD Air/gas ratio control with solenoid valve VAG Variable air/gas ratio control with solenoid valve VAV Pressure regulator with solenoid valve Air/gas ratio control with solenoid valve Variable air/gas ratio control with solenoid valve VAV Product brochure GB 3.1.0.4 Edition 03.08 All-purpose servo regulator

More information

Crest Heating Boilers FBN(L)

Crest Heating Boilers FBN(L) Replacement Parts List PARTS & SERVICE DEPARTMENT Nashville, Tennessee 877-554-5544 Fax: 615-882-2918 parts_team@lochinvar.com www.lochinvar.com Crest Heating Boilers FBN(L) 751-2001 59 IMG01113 52 65

More information

RS/M SERIES. Modulating Gas Burners FIRING RATES

RS/M SERIES. Modulating Gas Burners FIRING RATES The RS/M burners series covers a firing range from 45 to 2650 kw, and it has been designed for use in low or medium temperature hot water boilers, hot air or steam boilers, diathermic oil boilers. Operation

More information

D I V I S I O N O F M A R S H B E L L O F R A M

D I V I S I O N O F M A R S H B E L L O F R A M PH Regulator Large Capacity Working Media Include ir, Steam and Liquids ll Vents are Tapped The PH is a direct operating pressure reducing regulator with large capacity. Ideally suited for uses in oil

More information

VF VFH. elektrogas.com. Butterfly valves DN40 DN150 EE155-11/11

VF VFH. elektrogas.com. Butterfly valves DN40 DN150 EE155-11/11 VF VFH Butterfly valves DN40 DN150 elektrogas.com EE155-11/11 VF VFH Butterfly valves Contents Description.. 2 Features...... 2 Functioning and application.. 3 Technical specifications.... 4 Flow chart

More information

HS10S-FA. Water station. Product specification sheet

HS10S-FA. Water station. Product specification sheet HS10S-FA Water station Product specification sheet Range of Application Medium Drinking water Inlet pressure Max. 16 bar Outlet pressure 1.5-6.5 bar Installation position Horizontal with filter bowl downwards

More information

B21 Series BASOTROL Gas Valve

B21 Series BASOTROL Gas Valve Installation Instructions B21 Issue Date September 19, 2017 Installation IMPORTANT: These instructions are intended as a guide for qualified personnel installing or servicing BASO Gas Products. Carefully

More information

Differential pressure gauges with Bourdon tube

Differential pressure gauges with Bourdon tube Differential pressure gauges with Bourdon tube Nominal dia. and with movement of Brass or stainless steel measuring monitoring analysing Description These pressure gauges are suitable for measuring of

More information

RS/E-EV MZ SERIES. Modulating Gas Burners FIRING RATES

RS/E-EV MZ SERIES. Modulating Gas Burners FIRING RATES The RS/E-EV MZ burners series covers a firing range from 44 to 2650 kw, and it is based on a new Digital Burner Management System, Riello REC27, which is able to manage the air-fuel ratio by independent

More information

product Information on oil, gas and dual fuel burners Industrial burners 1,000 11,700 kw flexible and reliable

product Information on oil, gas and dual fuel burners Industrial burners 1,000 11,700 kw flexible and reliable product Information on oil, gas and dual fuel burners Minimale Industrial Emissionswerte burners mit Gas Industrial burners 1, 11,7 kw flexible and reliable Weishaupt Industrial Burners: Flexible and reliable

More information

VALUPAK. Packaged gas burners

VALUPAK. Packaged gas burners VALUPAK Packaged gas burners Low Temperature Burners - VALUPAK 1-1.5-1 High turndown. Available in 6 sizes. Capacities: 2 kw -1124 kw (HHV). Stable and clean combustion. Suitable for UV scanner and flame

More information

Kerosene - oil burner

Kerosene - oil burner Installation, use and maintenance instructions Kerosene - oil burner Two stage operation CODE MODEL TYPE 3746686 G0D 76T8 90 (0) TECHNICAL FEATURES Thermal power output 44 / 54 0 kw 3.7 / 4.5 0 kg/h Fuel

More information

AQUASTATS THERMOSTAT APPLICATION CONTENTS PRODUCT HANDBOOK

AQUASTATS THERMOSTAT APPLICATION CONTENTS PRODUCT HANDBOOK AQUASTATS THERMOSTAT PRODUCT HANDBOOK APPLICATION The L41../L61.. series aquastats are primarily designed for application on water filled heating systems and systems for hot water supply, mainly domestic

More information

CALEFFI. Pre-assembled distribution manifolds for radiant panel systems. series 663 & /05 NA. Function

CALEFFI. Pre-assembled distribution manifolds for radiant panel systems. series 663 & /05 NA. Function Pre-assembled distribution manifolds for radiant panel systems series & / NA Function Distribution manifolds for radiant panel systems are used to optimally distribute the heating fluid in floor heating

More information

Oil - kerosene burner

Oil - kerosene burner Installation, use and maintenance instructions Oil - kerosene burner One stage operation CODE MODEL TYPE 374445 G5 444T50 9038 () TECHNICAL FEATURES Thermal power output 8 0 kw.3 5 kg/h Fuel Gas oil 35s,

More information

Light oil - kerosene burner

Light oil - kerosene burner Installation, use and maintenance instructions Light oil - kerosene burner One stage operation CODE MODEL TYPE 3747455 G0KI 474T5 90403 (4) - 0/008 TECHNICAL DATA Thermal power output 95 3 kw 8 8 kg/h

More information

PREMIX TUNNEL BURNERS

PREMIX TUNNEL BURNERS FOR ENCLOSED GASAIR COMBUSTION MODEL: 01, 0, 06 Revision: 0 BULLETIN 01, 0, 06 EXPLODED VIEW Pyronic Tunnel Burners will burn any standard fuel gas at mixture pressures ranging from 0.1 to 60 W. C. Exclusive,

More information

Linea 28 Mark 1. Serial Number up to VOKERA SPARE PARTS BREAKDOWN

Linea 28 Mark 1. Serial Number up to VOKERA SPARE PARTS BREAKDOWN Linea 28 Mark 1 Serial Number up to 164370001 Outer Casing 1 RIVET 5093 5 LABEL 1781 2 LOCATING CLIP R/H 1881 6 CASE 1922 3 CLIP 5230 7 LOCATING CLIP L/H 1882 4 SELF ADHESIVE ALUM SHEET 5333 1 Main Frame

More information

1470 SERIES HOT AIR GAS BURNER

1470 SERIES HOT AIR GAS BURNER 1 SERIES HOT AIR GAS BURNER CAPABILITIES High or low temperature furnace High excess air 800% or more Ratio or tempered flame operation Nominal capacity range 0,000 to 3.5 MM Btu/hour Suitable for light

More information

Eclipse RatioAir Burners

Eclipse RatioAir Burners Data 115-1 10/1/07 Eclipse RatioAir Burners Main Specifications - RA0 PARAMETER Maximum input, () at neutral chamber conditions 60Hz Packaged Maximum input, () at neutral chamber conditions 50Hz Packaged

More information

RL/M BLU SERIES. Low NOx Modulating Light Oil Burners FIRING RATES. LOW NOx T. M 190/ kw M 223/ kw

RL/M BLU SERIES. Low NOx Modulating Light Oil Burners FIRING RATES. LOW NOx T. M 190/ kw M 223/ kw LOW NOx T The RL/M BLU burners series covers a firing range from 360 to 1023 kw, and it has been designed for use in hot or superheated water boilers, hot air or steam generators and diathermic oil boilers.

More information

M/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners

M/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners M/MR Modulating Valves design certified For Atmospheric, Infrared, and Direct Fired urners TALE OF CONTENTS Description/Specifications... 1 Introduction... 2 Direct Fired Applications (Negative Pressure)...

More information

1466 SERIES COLD AIR GAS/OIL BURNER

1466 SERIES COLD AIR GAS/OIL BURNER CAPABILITIES High or low temperature furnace High excess air 800% or more Ratio or tempered flame operation Nominal capacity range 0,000 to 3.5 MM Btu/hour Suitable for light wall construction FEATURES

More information

YARWAY NARVIK VEN-TEMP DESUPERHEATER MODEL 25

YARWAY NARVIK VEN-TEMP DESUPERHEATER MODEL 25 Yarway covers requirements for Desuperheaters, pneumatic actuators, strainers with a wide range of models, sizes and materials to satisfy all the specifications of the power, pulp and paper industry and

More information

RatioAir Burners. Model RA0750. Data /31/05. Main Specifications - RA0750

RatioAir Burners. Model RA0750. Data /31/05. Main Specifications - RA0750 Main Specifications - RA0750 PARAMETER Maximum input, Btu/hr (kw) at neutral chamber conditions. (Natural Gas) 60Hz Packaged 50Hz Packaged Minimum input, Btu/hr (kw) Lower inputs may be achieved. Contact

More information

Innovo Condensing high efficiency water heater

Innovo Condensing high efficiency water heater Condensing high efficiency water heater IR 12-160/20-160/12-200/20-200/24-245/32-245/ 24-285/32-285/32-380 A Fully room-sealed condensing high efficiency water heater Automatic gas/air premix burning system

More information

TriOx Triple Air Staged Ultra Low NOx Burner

TriOx Triple Air Staged Ultra Low NOx Burner Triple Air Staged Ultra Low NOx Burner TriOx-1 Edition 09-08 Ultra low NOx emissions of 20 ppm or less Invisiflame mode offers positive UV flame supervision throughout entire operating range for excellent

More information

XID ENHANCEMENT SYSTEM IMPROVED EFFICIENCY AND PERFORMANCE

XID ENHANCEMENT SYSTEM IMPROVED EFFICIENCY AND PERFORMANCE IMMERSION FIRED HOT WATER BOILER April 1, 2003 GENERAL DESCRIPTION The Sellers immersion fired hot water boiler is a horizontal, single pass, firetube boiler designed to burn natural gas. The unique burner

More information

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model ACO. R EN - Edition 04-01/04/2008

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model ACO. R EN - Edition 04-01/04/2008 SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model ACO R8215222-04EN - Edition 04-01/04/2008 Domestic Gas Boilers ACO 537060 ACO 27 MFFI MET...... 537061 ACO 27 MFFI GPL...... 537062 ACO 27 RFFI SYSTEM MET......

More information

SPARE PARTS LIST - July

SPARE PARTS LIST - July Versions for CANADA SPARE PARTS LIST - July 2005 - HOW TO READ THE SPARE PARTS CATALOGUE In the spare part catalogue, after the exploded diagrams, there are the components lists of the boilers; this is

More information

RatioAir Burners. Model RA1000. Data /31/05. Main Specifications - RA1000

RatioAir Burners. Model RA1000. Data /31/05. Main Specifications - RA1000 Main Specifications - RA1000 PARAMETER Maximum input, Btu/hr (kw) at neutral chamber conditions. (Natural Gas) 60Hz Packaged Blower 50Hz Packaged Blower Minimum input, Btu/hr (kw) Lower inputs may be achieved.

More information

Controls and Accessories Part Number Controls and Accessories Part Number

Controls and Accessories Part Number Controls and Accessories Part Number Linea 24 Mark 1 Serial Number Up to 161380001 Controls and Accessories Part Number Controls and Accessories Part Number CLOCK - MECHANICAL 201 CLOCK - DIGITAL 202 CONVERSION KIT LPG - NG 01005225 CONVERSION

More information

V2000FS FS type TRV Body FINELY PRESETTABLE RADIATOR VALVE WITH FLUSH POSITION

V2000FS FS type TRV Body FINELY PRESETTABLE RADIATOR VALVE WITH FLUSH POSITION V2000FS FS type TRV Body FINELY PRESETTABLE RADIATOR VALVE WITH FLUSH POSITION PRODUCT DATA Application 011 Angle to DIN Angle to NF Straight to DIN Straight to NF Thermostatic radiator valve bodies (TRV

More information

ONE STAGE GAS BURNERS RDBS SERIES

ONE STAGE GAS BURNERS RDBS SERIES ONE STAGE GAS BURNERS RDBS SERIES 16 47 kw RDBS.1 16 47 kw The Riello RDBS is a new series of one stage gas burners with integrated gas train, characterised by its small dimensions in spite of its high

More information

VKF41...C. Butterfly Valves. Building Technologies Division Industry Sector

VKF41...C. Butterfly Valves. Building Technologies Division Industry Sector 7 62 Butterfly Valves VKF41...C Butterfly valves designed for fitting between counter-flanges, for integration into gas trains Disk with metallically tight shutoff DN40...DN200 Angle of rotation 85 No

More information

Sentronic LP IO-Link CLASS A 617 Series. Proportional Technology

Sentronic LP IO-Link CLASS A 617 Series. Proportional Technology Sentronic LP IO-Link CLASS A 617 Series Proportional Technology PROPORTIONAL PRESSURE CONTROL: 617 SERIES SENTRONIC LP IO-LINK VERSION ASCO NUMATICS Sentronic LP The Sentronic LP is a highly efficient

More information

Combination controls CG 10

Combination controls CG 10 Combination controls CG 0... Edition 03. GB Combination controls CG 0 Complete with strainer, two solenoid valves and servo-governor for maximum regulation precision. Special low-noise valves. Optional

More information

Differential Pressure Switch QBM81-

Differential Pressure Switch QBM81- s 1 552 Differential Pressure Switch QBM81- for air and nonaggressive gases For ventilation and air conditioning plants To monitor air filters, air flow, fan belts To monitor pressure in clean rooms, kitchens

More information

11A-1 ENGINE CONTENTS

11A-1 ENGINE CONTENTS 11A-1 ENGINE CONTENTS ENGINE ENGINE ... 11A... 11B 11A-2 ENGINE CONTENTS GENERAL... 3 Outline of Changes... 3 GENERAL INFORMATION... 3 SERVICE SPECIFICATIONS... 3 SEALANT... 3 SPECIAL

More information

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model UNO. R EN - Edition 01-15/10/2007

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model UNO. R EN - Edition 01-15/10/2007 SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model R8216080-01EN - Edition 01-15/10/2007 537255 24 MFFI (RO) MET...... 537256 24 MFFI (RO) GPL...... 537632 24 MFFI MET (PL, CZ, UCR)...... 537633 24 MFFI

More information

3/2-way Solenoid Valve for pneumatics

3/2-way Solenoid Valve for pneumatics 656 3/-way Solenoid Valve for pneumatics Compact design Single and manifold mounting Low power consumption Rocker pilot in DC Type 656 can be combined with... Fast response times Type 506 Type 510/511

More information

Error codes Diagnostic plug Read-out Reset Signal Error codes

Error codes Diagnostic plug Read-out Reset Signal Error codes Error codes Diagnostic plug Diagnostic plug: 1 = Datalink LED tester (FEN) 3 = activation error codes (TEN) 4 = positive battery terminal (+B) 5 = ground Read-out -Connect LED tester to positive battery

More information

Q5020A-D Globe Valve Linkages FOR DIRECT COUPLED ACTUATORS

Q5020A-D Globe Valve Linkages FOR DIRECT COUPLED ACTUATORS Q5020A-D Globe Valve Linkages FOR DIRECT COUPLED ACTUATORS FEATURES PRODUCT DATA Used with 2- and 3- globe valves in modulating or two-position service. Used with 25, 50, and 142 lb-in. spring return and

More information

Yarway Narvik Ven-Temp Desuperheater Model 25

Yarway Narvik Ven-Temp Desuperheater Model 25 Yarway covers requirements for Desuperheaters, pneumatic actuators, strainers with a wide range of models, sizes and materials to satisfy all the specifications of the power, pulp and paper industry and

More information

3/2-way and 2 x 3/2-way Solenoid Valve for pneumatics

3/2-way and 2 x 3/2-way Solenoid Valve for pneumatics 654 3/-way and x 3/-way Solenoid Valve for pneumatics Compact design Single and manifold mounting Low power consumption Fast response times Space saving ( x 3/-way version) Type 654 can be combined with...

More information

VLF45... Hot Air Valves. Siemens Building Technologies HVAC Products

VLF45... Hot Air Valves. Siemens Building Technologies HVAC Products 7 637 Hot Air Valves VLF45... Single valve for use in the supply air line of heat generating equipment Valves used in connection with SKP... actuators open slowly and close rapidly 2-port valves of the

More information

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS 27 BFFI PLUS Edition 4 Current from Serial No: 2320317800001 to: ------------------ Add to Edition 3 1 71 70 9 8 7 5 9 3 4 3 5 7 5 1 2 1 8 9 120 0

More information

Performance. Perkins Engines Company Limited. Perkins Engines Company Limited. Peterborough PE1 5FQ United Kingdom Tel: +44 (0)

Performance. Perkins Engines Company Limited. Perkins Engines Company Limited. Peterborough PE1 5FQ United Kingdom Tel: +44 (0) 105 kwm (Gross) @ 1500 rpm ElectropaK 1100 Series Basic technical data Number of cylinders.....................................................4 Cylinder arrangement...................................

More information

DEUTZ Engine Documentation Genset Manual. BF4M2012C (D2OC74,9) - 50 Hz 1/5 DEUTZ AG

DEUTZ Engine Documentation Genset Manual. BF4M2012C (D2OC74,9) - 50 Hz 1/5 DEUTZ AG 1/5 DEUTZ AG Technical data General engine data Engine Type BF4M2012C EKZ 11372 Speed 1500 min -1 Net frequency Exhaust emission standard 50 Hz Stage II Specific engine data Aspiration No of cylinders

More information

Air Cooler Industry AC-LN 8-14 / ACA-LN 8-11 / ACAF-LN 8-11

Air Cooler Industry AC-LN 8-14 / ACA-LN 8-11 / ACAF-LN 8-11 Air Cooler Industry AC-LN 8-14 / ACA-LN 8-11 / ACAF-LN 8-11 Symbol General The AC-LN 8-14 air cooler series can be used in all areas where either oil or water-glycol is to be cooled with air. The coolers

More information

LVDT/HC PILOT BURNER. External raw gas pilot burner

LVDT/HC PILOT BURNER. External raw gas pilot burner 4-22.4-1 LVDT/HC PILOT URNER External raw gas pilot burner Stable pilot flame in combination with MXON IRFLO LV, HC, DELT-TE and COMUSTIFUME burners Rugged design urns natural gas, propane and LPG Suitable

More information

COMBI OVENS SI EQUATOR 6 BUILDER S SPECIFICATIONS. Part C: Maintenance manual 3BE390691NM

COMBI OVENS SI EQUATOR 6 BUILDER S SPECIFICATIONS. Part C: Maintenance manual 3BE390691NM EQUATOR 6 COMBI OVENS SI BUILDER S SPECIFICATIONS Part C: Maintenance manual - WARRANTY - In order to guarantee this equipment, we recommend that you comply with the MANUFACTURER S INSTRUCTIONS in this

More information

G76x Direct Spark Ignition Controls

G76x Direct Spark Ignition Controls Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin G76x Issue Date 0400 G76x Direct Spark Ignition Controls Figure 1: G76x Direct Spark Ignition

More information

UB95M-200 Gas-Fired Direct Vent Modulating Hot Water Boiler

UB95M-200 Gas-Fired Direct Vent Modulating Hot Water Boiler UB9M-200 Gas-Fired Direct Vent Modulating Hot Water Boiler Repair Parts Manual Ordering Instructions Order Parts through your nearest supplier. When ordering parts, obtain Model Number and Serial Number

More information

Differential-Pressure Flow Meter

Differential-Pressure Flow Meter Design and application The metering orifice measures and monitors the flow rate of liquids. The user mounts the orifice between flanges or with Rp screwed connections into the conduit. The unimpeded, straight

More information

V5003F Kombi-VX PRE-SETTABLE FLOW CONTROL VALVE

V5003F Kombi-VX PRE-SETTABLE FLOW CONTROL VALVE V5003F Kombi-VX PRE-SETTABLE FLOW CONTROL VALVE PRODUCT DATA 5 4 3 1 7 Application The V5003F Kombi-VX is an automatic balancing valve. It is designed for balancing of heating and cooling systems by providing

More information

M436A/M836A,B Damper Motors

M436A/M836A,B Damper Motors M436A/M836A,B Damper Motors FEATURES INSTALLATION INSTRUCTIONS APPLICATION M436A/M836A,B Damper Motors are spring return (SR) motors used for residential and light commercial applications in Series 40

More information

Doing more for clean environment and energy saving

Doing more for clean environment and energy saving Doing more for clean environment and energy saving Rütli Burners Switzerland AG is a worldwide leading industrial burner solution supplier. Our head quarter is located in Schaffhausen, Switzerland one

More information

Spare parts catalogue GB 07/2008. Wall-hung boilers ecotec VU 466/4-5 VU 656/4-5

Spare parts catalogue GB 07/2008. Wall-hung boilers ecotec VU 466/4-5 VU 656/4-5 Spare parts catalogue 0020067960.02 GB 07/2008 Wall-hung boilers ecotec VU 466/4-5 VU 656/4-5 Content General view of sheet VU 466/4-5 Page 3 04 Burner Page 4 06 Heat exchanger Page 6 07 Casing parts

More information

FRM. Medium Pressure Regulator. Medium pressure regulator Type FRM

FRM. Medium Pressure Regulator. Medium pressure regulator Type FRM FRM Medium Pressure Regulator Medium pressure regulator Type FRM Direct acting pressure regulator with adjustable setpoint springs and modular mounted safety shutoff valve (SAV) In compliance with EN 334

More information

SPARE PARTS CATALOGUE

SPARE PARTS CATALOGUE SPARE PARTS CATALOGUE - October 2015 - HOW TO READ THE SPARE PARTS CATALOGUE In the spare part catalogue, after the exploded diagrams, there are the components lists of the boilers; this is the meaning

More information

NOx-Beta Ultra Low NOx Burners

NOx-Beta Ultra Low NOx Burners NOx-Beta Ultra Low NOx s February NOx-Beta Features Ultra low NOx without any performance loss Staged air principle no external NOx reducing devices or FGR needed Robust, well engineered construction Cost

More information

Weishaupt gas burners Sizes 30 to 70 Version NR (NO x reduced)

Weishaupt gas burners Sizes 30 to 70 Version NR (NO x reduced) Weishaupt gas burners Sizes 30 to 70 Version NR (NO x reduced) Description Weishaupt industrial burners, sizes 30 to 70, have been especially designed for industrial capacity ranges. The monobloc burners

More information

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model ACO. R EN - Edition 06-01/12/2010

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model ACO. R EN - Edition 06-01/12/2010 SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model ACO R8215222-06EN - Edition 06-01/12/2010 Domestic Gas Boilers ACO 537060 ACO 27 MFFI MET...... 537061 ACO 27 MFFI GPL...... 537062 ACO 27 RFFI SYSTEM MET......

More information

BGD258 Series BASOTROL CE Approved Class A Gas Valve

BGD258 Series BASOTROL CE Approved Class A Gas Valve Product Bulletin Issue Date May 21, 2010 BGD258 Series BASOTROL CE Approved Class A Gas Valve The BGD258 Series multi-function gas control valve works in conjunction with an electronic sequence control

More information

NARVIK-YARWAY. Heavy Duty A.T. - Temp Desuperheater Model: 18/54 and 28/64

NARVIK-YARWAY. Heavy Duty A.T. - Temp Desuperheater Model: 18/54 and 28/64 NARVIK-YARWAY Narvik-Yarway covers requirements for Desuperheaters, pneumatic actuators, strainers with a wide range of models, sizes and materials to satisfy all the specifications of the power-pulp &

More information

Figure 1-1(d) Tft Installation Kit

Figure 1-1(d) Tft Installation Kit TRINITY TFT60-399 PARTS LIST For a list of parts that corresponds to the item numbers in the callouts, refer to Table 1-1. Note that some item numbers may appear more than once in the parts list depending

More information

Product Information. Model: LNVG, LNVLG Burner Sizes: 13, 15, 17, 20, 21, 25 GENERAL DESCRIPTION U.L. STANDARD EQUIPMENT

Product Information. Model: LNVG, LNVLG Burner Sizes: 13, 15, 17, 20, 21, 25 GENERAL DESCRIPTION U.L. STANDARD EQUIPMENT The LNV/Series gas, oil, and combination gas/oil burner is a forced draft packaged burner system. A balanced blower wheel mounted in a fabricated housing provides combustion air for various furnace pressures

More information

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves Electrically modulating GB-M(P) 057 D01

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves Electrically modulating GB-M(P) 057 D01 Gasloc Multifunctional gas control Combined regulator and safety shut-off valves Electrically modulating G-M(P) 057 D01 Two stage operating mode G-(LEP)Z 057 D01 Technical Description Multifunctional gas

More information

G600 Series Replacement Intermittent Pilot Ignition Controls

G600 Series Replacement Intermittent Pilot Ignition Controls Installation Instructions G600 Issue Date 0601 G600 Series ment Intermittent Pilot Ignition Controls Installation IMPORTANT: These instructions are intended as a guide for qualified personnel installing

More information