1 / VENTURI MANIFOLD FOR VK41.5V/VK81.5V GAS CONTROLS PRODUCT HANDBOOK APPLICATION The venturi manifold combined with the VK41.5V/VK81.5V gas controls and a specific DC-fan is called CVI-vf (Combined Valve Ignition, venturi and fan) and has been specially developed for modulating fully premix appliances. Note: The information of this handbook supplements those of the Product Handbook EN2R-9004 of The Combined Valve and Ignition systems (CVI) and the product handbook EN2R-9017 of the V5306V integrated 1:1 gas/air regulator The information of this handbook specifies the today supplementary features and data but also limitations on models and specifications of the CVI Gas Control with the / venturi manifold. Subject to change without notice. All rights reserved. General Contents Description... 2 Features... 2 Technical Specifications... 3 Dimensional drawing... 4 Dimensional drawing venturi manifold... 5 Adjustments and Checkout... 6 Various Standards and approvals... 6 Application notes... 6 Ordering information... 7 Accessories EN2R R13-NE
2 DESCRIPTION The venturi manifold is a gas/air mixing unit that allows modulation of a premix burner with constant gas/air ratio down to 20% of maximum load. It is to be used in combination with a fan and a Honeywell 1:1 regulating gas valve. The modulation is accomplished by changing the fan speed. The outlet pressure of the gas valve is regulated to ambient pressure by the gas valve. The venturi generates a negative pressure against ambient by which the gas is drawn through the gas valve outlet. The venturi manifold system is designed to be fitted in up to eight positions on a specially adapted DC fan, using two supplied M5 thread forming screws. The venturi manifold is sealed with a gasket that is supplied with the assembly. The gas valve can be fitted directly on the manifold assembly in horizontal and vertical position with both the side outlet and the end outlet. Four M4 screws and a special NBR gasket are used for the end outlet version. Three M5 screws and a special sealing ring are used for the side outlet version. The venturi manifold can be trimmed to the correct gas/air ratio by turning the throttle screw FEATURES The following features are deviating from Product handbook VK41../VK81.. series (EN2R-9004) General In combination with CVI, all burner control and safety functions are concentrated in one optimised system (function integration) All adjustments and test points from one (top) side accessible. Wide modulation band ( % boiler load) or lower fan speed at normal modulation band ( % boiler load) are possible. Flexible mounting positions of gas control to venturi housing and venturi housing to fan. Built in throttle function (venturi manifold) for adjustment on gas type. Options LP gas models with integrated injection orifice. EN2R R13-NE 2
3 SPECIFICATIONS Model Code 1) Inlet and outlet code 2) Reference load 3) x kw x kw x kw x50 *) kw x kw x kw x kw x kw 1 )x = 0: with gasket and screws x = 2: without gasket and screws 2 ) The inlet and outlet codes are visible on the top and bottom plastic parts. 3 ) The reference load is the gross boiler load at which the venturi has an overall pressure drop of 450 Pa Dimensions See Dimensional drawing on page 4 Ambient temperature C Gas valve connection A flange connection set is required to mount the manifold assembly onto the gas valve. (See Accessories on page 8) Minimum load The minimum load for which the unit can be used is 20% of the reference load, which equals a minimum pressure differential of 50 Pa of the 1:1 gas control. Throttle range With the throttle an air factor of 1.3 is adjustable in the H, L and LL-band of natural gas. Material Housing: ZnAl4Cu1 (Z410, Zamac Z5) Venturi: statically dissipative POM Throttle screw: brass Fan plate gasket: cork nitrile rubber Seals: rubber (NBR) Pressure drop 450 Pa maximum at reference load. (Overall pressure drop of the venturi) Venturi pressure 1250 Pa minimum at reference load. (The venturi pressure is the determination of the effective gas pressure) Tracking inaccuracy (not applicable for inlet and outlet code 050 * ) The tracking inaccuracy is the deviation from a constant gas/ air ratio over the modulation band % Typical: 10% without internal injection orifice. 5% with internal injection orifice. Code x55: 15% without internal injection orifice. 7.5% with internal injection orifice. *) Only suitable in specially adapted applications 3 EN2R R13-NE
4 DIMENSIONAL DRAWING 60 G.126/RG130 Air inlet Gas inlet CVI R1 EN2R R13-NE 4
5 DIMENSIONAL DRAWING VENTURI MANIFOLD R38 Screw M5 thread forming at R '(2x) R48 Ø (2) EN2R R13-NE
6 ADJUSTMENTS AND CHECKOUT Adjustment Check gas input to the appliance using a pressure gauge (resolution of 1 Pa (0.01 mbar) or better) connected to the outlet pressure tap. Put CO 2 meter probe (inaccuracy < 0.1%) into exhaust gas outlet. Screw throttle adjustment screw approx. half way down (about 10 mm turned down). ❶ Start appliance ❷ Run appliance at maximum load. ❸ Observe CO 2 meter and adjust throttle screw until CO 2 percentage is at nominal value.turn throttle screw clockwise to reduce gas flow and CO 2 percentage ❹ If appliance does not start, turn throttle screw three turns counter clockwise and repeat starting procedure. ❺ Keep appliance running until completely stabilised, accurate adjustment when necessary. ❻ Set appliance to minimum load. ❼ Check offset pressure according to the manufacturer s instructions. Repeat from 1 to 6 inclusive when adjustment of offset pressure was necessary. After adjustments are made, stop appliance, disconnect pressure gauge and CO 2 meter and tighten outlet pressure tap. Final checkout of the installation After any adjustment, set appliance in operation. Observe several complete cycles to ensure that all burner components function correctly. STANDARDS AND APPROVALS The venturi manifold is not certified separately. It will be certified as part of the appliance. APPLICATION NOTES Make sure the venturi inlet is not obstructed. This will influence the air factor. If the distance from another boiler component to the venturi inlet is more than 50 mm, air factor and boiler load are not influenced. There is a strong interaction between the venturi, gas control and burner. For this reason it is important to fit the characteristics of these components to each other. If not matched well, for instance acoustic problems could be generated. It is recommended to test the appliance at both cold start and hot start conditions with high and low caloric test gases. EN2R R13-NE 6
7 ORDERING INFORMATION When ordering specify: Order number of venturi manifold required: see table below. Ordering Specification Reference load number kw kw kw ) 56 kw ) 40 kw ) 27 kw )* 82 kw ) 72 kw ) 46 kw ) 34 kw 1) without gasket and screws. * only suitable in specially adapted applications. Model number of VK41.5V/VK81.5V gas control. The fan should be obtained from the fan manufacturer: G.126 of EBM or RG130 from MVL. Order numbers of replacement parts and accessories required: See Accessories on page 8. Note: Most models of valves, replacement parts and accessories will be available under TRADELINE label. Ask your wholesaler for details. 7 EN2R R13-NE
8 ACCESSORIES Accessories for VK41.5/VK81.5V series gas controls Description Packing quantity Ordernumber Sealing ring and screws for mounting onto side outlet Gasket and screws for mounting onto end outlet Sealing ring for mounting onto side outlet Gasket for mounting onto fan Gasket for mounting onto fan Screws for mounting fan onto venturi Orifice for LPG application Code venturi Orifice dia (mm) Packing quantity Order number x x x x x x x Manufactered for and on behalf of the Environmental and Combustion Controls Division of Honeywell Sàrl, Ecublens, Route du Bois 37, Switzerland by its Autorized Representative: Automation and Control Solutions Combustion Controls Europe Honeywell BV Phileas Foggstraat AJ Emmen The Netherlands Tel.: +31 (-) Fax: +31 (-) EN2R R13-NE 8
VE4000 & VE5000 SERIES
VE4000 & VE5000 SERIES CLASS "A" GAS VALVES PRODUCT HANDBOOK APPLICATION These series class A gas valves are used for control and regulation of gaseous fluids in gas power burners, atmospheric gas boilers,
More informationHoneywell VV, VP, VB & MS SERIES FOR VQ400M CLASS A VALVES PRODUCT HANDBOOK APPLICATION
Honeywell VV, VP, VB & MS SERIES FOR VQ400M CLASS A VALVES PRODUCT HANDBOOK APPLICATION The VV Series class A vent valves are intended to be used in combination with the VQ400M series combination valve.
More informationVQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION
VQ400M SERIES PRODUCT HANDBOOK APPLICATION The VQ400M Series class A safety combination valves are used for control and regulation of gaseous fluids in gas power burners, atmospheric gas boilers, melting
More informationVR400/VR800 series UNIVERSAL GAS VALVES CLASS A SERVO REGULATED COMBINATION VALVES APPLICATION. Contents PRODUCT HANDBOOK. General
UNIVERSAL GAS VALVES VR00/VR800 series CLASS A SERVO REGULATED COMBINATION VALVES APPLICATION PRODUCT HANDBOOK The VR00 Series class A servo regulated combination valves are used for control and regulation
More informationVE Series. Class "A" Gas Valves. Product handbook APPLICATION CONTENTS. General. Technical. Installation and operation. Various
Class "A" Gas Valves Product handbook APPLICATION These series class A gas valves are used for control and regulation of gaseous fluids in gas power burners, atmospheric gas boilers, melting furnaces,
More informationS4562C 1085 COMBI BOARD APPLICATION. Contents PRODUCT HANDBOOK. General
S4562C 1085 COMBI BOARD APPLICATION PRODUCT HANDBOOK The S4562C 1085 combi board is an integration of an on/off temperature control and an electronic ignition control. The S4562C 1085 combi board is intended
More informationAQUASTATS THERMOSTAT APPLICATION
AQUASTATS THERMOSTAT APPLICATION PRODUCT HANDBOOK The L41../L61.. series aquastats are primarily designed for application on water filled heating systems and systems for hot water supply, mainly domestic
More information822 NOVAMIX GAS FLOW RATE ADJUSTMENT AS A FUNCTION OF THE AIR FLOW GAS/AIR RATIO 1:1 DOUBLE AUTOMATIC SOLENOID SHUT-OFF VALVE
SIT Group 822 NOVAMIX MULTIFUNCTIONAL GAS CONTROL GAS FLOW RATE ADJUSTMENT AS A FUNCTION OF THE AIR FLOW GAS/AIR RATIO 1:1 DOUBLE AUTOMATIC SOLENOID SHUT-OFF VALVE SERVO-CONTROLLED PRESSURE REGULATOR PIN
More informationV5049A FLANGED LINEAR VALVE PN25/40
V549A FLANGED LINEAR VALVE PN25/4 FEATURES SPECIFICATION DATA Cast iron or cast steel body with flanged end connections Low seat leakage rate Metal-to-metal seating for long life span Self-adjusting packing
More informationLKS 160 FOR AIR DAMPERS ON MULTI-STAGE AND MODULATING BURNERS
ACTUATOR LKS 160 FOR AIR DAMPERS ON MULTI-STAGE AND MODULATING BURNERS PRODUCT HANDBOOK APPLICATION The LKS 160 air damper actuator is designed to be fitted to multi-stage or modulating oil and gas burners
More informationEclipse RatioAir Burners
Parameter Maximum Input, BTU/hr (kw) 1, Minimum Input, BTU/hr (kw) Lower inputs may be achieved. Contact factory. Main Gas Inlet Pressure, "w.c. (mbar) 3 Fuel pressure at ratio regulator inlet. High Fire
More informationGV30 / GV30A SERIES GAS COMBINATION CONTROL SYSTEMS FOR COMMERCIAL COOKING APPLIANCES.
GV0 / GV0A SERIES GAS COMBINATION CONTROL SYSTEMS FOR COMMERCIAL COOKING APPLIANCES R www.mertikmaxitrol.com CONTENT GENERAL INFORMATION GV0 AND GV0A STANDARD FEATURES OPTIONAL TEMPERATURE KNOBS AND D-STEMS
More informationEW447-EW452 Series Mechanical Heat Meters FOR HEATING AND COOLING APPLICATIONS
EW447-EW452 Series Mechanical Heat Meters FOR HEATING AND COOLING APPLICATIONS Application PRODUCT DATA Static compact heat meter with electronic measurement, consisting of electronic energy integrator
More informationRS/1 SERIES. One Stage Gas Burners RS 34/1 MZ RS 44/1 MZ kw kw GAS
The RS/1 series of burners covers a firing range from 70 to 550 kw, and they have been designed for use in low or medium temperature hot water boilers, hot air or steam boilers, diathermic oil boilers.
More informationVQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION
VQ400M SERIES PRODUCT HANDBOOK APPLICATION The VQ400M Series class A safety combination valves are used for control and regulation of gaseous fluids in gas power burners, atmospheric gas boilers, melting
More informationVICTRIX PRO Wall-hung modular condensing boiler for heating only
PRO Wall-hung modular condensing boiler for heating only Wide range (5 models) High efficiency and low pollutant emissions thanks to condensing technology Modulating heat output from 10 to 100% Possible
More informationValencia Radiator Valve Range
Valencia Radiator Valve Range VTL00 VTL0 VHL0 VT00 VT Application PRODUCT DATA SHEET Thermostatic Radiator Valves (TRVs) provide local control of room temperatures to maintain comfort and save energy.
More informationS1024-2POS / S POS S2024-2POS / S POS
GENERAL S0-POS / S00-POS S0-POS / S00-POS SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS 0/0 Nm (88/77 lb-in) FOR -POSITION CONTROL These direct-coupled damper actuators provide two-position control for:
More information2-port ball valves with flanged connection, PN25
s 4 120 ACVATIX 2-port ball valves with flanged connection, PN25 VAF51.. Gray cast iron EN-GJL-250 (HT250) valve body DN 65...150 k vs 63...360 m 3 /h Angle of rotation 90 Flange connection to ISO 7005-2
More informationV5050A,B FLANGED LINEAR VALVE PN16 AND PN25/40
V55A,B FLANGED LINEAR VALVE PN16 AND PN25/4 GENERAL These threeport mixing valves are used for modulating control of hot/chilled water or steam in heating, ventilation, and air conditioning systems and
More informationRS SERIES. Two Stage Progressive Gas Burners FIRING RATES
The RS burners series covers a firing range from 44 to 2290 kw, and it has been designed for use in low or medium temperature hot water boilers, hot air or steam boilers, diathermic oil boilers. Operation
More informationP95H Regulator Applications P95H Part Matrix Specifi cations Materials of Construction P95H Flow Coeffi cients Wide Open Coeffi cients
PH Regulator Large Capacity Working Media Include ir, Steam and Liquids ll Vents are Tapped The PH is a direct operating pressure reducing regulator with large capacity. Ideally suited for uses in oil
More informationavailable in battery up to 4 units for a total of 560 kw
MODULATING CONDENSING BOILER with double premix low NOx burner and double heat exchanger EXPANDABLE IN BATTERY for indoor and outdoor installations (IPX5D) OUTPUT RANGE from 10 to 560 kw (in battery) WORKING
More informationV5197A Firing Rate Gas Valve
V5197A Firing Rate Gas Valve FEATURES PRODUCT DATA APPLICATION The V5197A is a firing rate valve used to provide variable flow control of air, natural gas, liquefied petroleum (LP), and manufactured gases.
More informationLKS 170 FOR AIR DAMPERS ON SINGLE, DUAL STAGE AND MODULATING BURNERS
ACTUATOR LKS 170 FOR AIR DAMPERS ON SINGLE, DUAL STAGE AND MODULATING BURNERS PRODUCT HANDBOOK APPLICATION The LKS 170 air damper actuator is designed to be fitted to multi-stage or modulating oil and
More informationFO-BV Series. Fixed-orifice balancing and control valves. Technical Data Sheet. WattsIndustries.com
FO-BV Series Fixed-orifice balancing and control valves Technical Data Sheet WattsIndustries.com Description FO-BV Series fixed-orifice threaded valves are designed for flow control and monitoring in climate
More informationVQ400M SERIES CLASS A COMBINATION VALVES INSTRUCTION SHEET APPLICATION
VQ400M SERIES INSTRUCTION SHEET APPLICATION The VQ400M Series class A safety combination valves are used for control and regulation of gaseous fluids in gas power burners, atmospheric gas boilers, melting
More informationCHALLENGER Propane to Natural Gas Instructions
Kit Part Number: CCRKIT02 Kit Includes: - Rating Label - (3) Natural Gas Orifices - T-15 Torx Wrench Recommended Tools: - Phillips-Head Screwdriver - Standard Adjustable Wrenches - Calibrated Combustion
More informationCODE MODEL TYPE G3BF 490T G5BF 492T G5BF 489T53
Installation, use and maintenance instructions Kerosene burners One stage operation CODE MODEL TYPE 3749053 G3BF 490T53 374957 G5BF 49T57 3748953 G5BF 489T53 9036 (6) TECHNICAL FEATURES TYPE - Boiler
More informationHS10S-FA. Water station. Product specification sheet
HS10S-FA Water station Product specification sheet Range of Application Medium Drinking water Inlet pressure Max. 16 bar Outlet pressure 1.5-6.5 bar Installation position Horizontal with filter bowl downwards
More informationPressure regulator with solenoid valve VAD Air/gas ratio control with solenoid valve VAG Variable air/gas ratio control with solenoid valve VAV
Pressure regulator with solenoid valve Air/gas ratio control with solenoid valve Variable air/gas ratio control with solenoid valve VAV Product brochure GB 3.1.0.4 Edition 03.08 All-purpose servo regulator
More informationCrest Heating Boilers FBN(L)
Replacement Parts List PARTS & SERVICE DEPARTMENT Nashville, Tennessee 877-554-5544 Fax: 615-882-2918 parts_team@lochinvar.com www.lochinvar.com Crest Heating Boilers FBN(L) 751-2001 59 IMG01113 52 65
More informationRS/M SERIES. Modulating Gas Burners FIRING RATES
The RS/M burners series covers a firing range from 45 to 2650 kw, and it has been designed for use in low or medium temperature hot water boilers, hot air or steam boilers, diathermic oil boilers. Operation
More informationD I V I S I O N O F M A R S H B E L L O F R A M
PH Regulator Large Capacity Working Media Include ir, Steam and Liquids ll Vents are Tapped The PH is a direct operating pressure reducing regulator with large capacity. Ideally suited for uses in oil
More informationVF VFH. elektrogas.com. Butterfly valves DN40 DN150 EE155-11/11
VF VFH Butterfly valves DN40 DN150 elektrogas.com EE155-11/11 VF VFH Butterfly valves Contents Description.. 2 Features...... 2 Functioning and application.. 3 Technical specifications.... 4 Flow chart
More informationHS10S-FA. Water station. Product specification sheet
HS10S-FA Water station Product specification sheet Range of Application Medium Drinking water Inlet pressure Max. 16 bar Outlet pressure 1.5-6.5 bar Installation position Horizontal with filter bowl downwards
More informationB21 Series BASOTROL Gas Valve
Installation Instructions B21 Issue Date September 19, 2017 Installation IMPORTANT: These instructions are intended as a guide for qualified personnel installing or servicing BASO Gas Products. Carefully
More informationDifferential pressure gauges with Bourdon tube
Differential pressure gauges with Bourdon tube Nominal dia. and with movement of Brass or stainless steel measuring monitoring analysing Description These pressure gauges are suitable for measuring of
More informationRS/E-EV MZ SERIES. Modulating Gas Burners FIRING RATES
The RS/E-EV MZ burners series covers a firing range from 44 to 2650 kw, and it is based on a new Digital Burner Management System, Riello REC27, which is able to manage the air-fuel ratio by independent
More informationproduct Information on oil, gas and dual fuel burners Industrial burners 1,000 11,700 kw flexible and reliable
product Information on oil, gas and dual fuel burners Minimale Industrial Emissionswerte burners mit Gas Industrial burners 1, 11,7 kw flexible and reliable Weishaupt Industrial Burners: Flexible and reliable
More informationVALUPAK. Packaged gas burners
VALUPAK Packaged gas burners Low Temperature Burners - VALUPAK 1-1.5-1 High turndown. Available in 6 sizes. Capacities: 2 kw -1124 kw (HHV). Stable and clean combustion. Suitable for UV scanner and flame
More informationKerosene - oil burner
Installation, use and maintenance instructions Kerosene - oil burner Two stage operation CODE MODEL TYPE 3746686 G0D 76T8 90 (0) TECHNICAL FEATURES Thermal power output 44 / 54 0 kw 3.7 / 4.5 0 kg/h Fuel
More informationAQUASTATS THERMOSTAT APPLICATION CONTENTS PRODUCT HANDBOOK
AQUASTATS THERMOSTAT PRODUCT HANDBOOK APPLICATION The L41../L61.. series aquastats are primarily designed for application on water filled heating systems and systems for hot water supply, mainly domestic
More informationCALEFFI. Pre-assembled distribution manifolds for radiant panel systems. series 663 & /05 NA. Function
Pre-assembled distribution manifolds for radiant panel systems series & / NA Function Distribution manifolds for radiant panel systems are used to optimally distribute the heating fluid in floor heating
More informationOil - kerosene burner
Installation, use and maintenance instructions Oil - kerosene burner One stage operation CODE MODEL TYPE 374445 G5 444T50 9038 () TECHNICAL FEATURES Thermal power output 8 0 kw.3 5 kg/h Fuel Gas oil 35s,
More informationLight oil - kerosene burner
Installation, use and maintenance instructions Light oil - kerosene burner One stage operation CODE MODEL TYPE 3747455 G0KI 474T5 90403 (4) - 0/008 TECHNICAL DATA Thermal power output 95 3 kw 8 8 kg/h
More informationPREMIX TUNNEL BURNERS
FOR ENCLOSED GASAIR COMBUSTION MODEL: 01, 0, 06 Revision: 0 BULLETIN 01, 0, 06 EXPLODED VIEW Pyronic Tunnel Burners will burn any standard fuel gas at mixture pressures ranging from 0.1 to 60 W. C. Exclusive,
More informationLinea 28 Mark 1. Serial Number up to VOKERA SPARE PARTS BREAKDOWN
Linea 28 Mark 1 Serial Number up to 164370001 Outer Casing 1 RIVET 5093 5 LABEL 1781 2 LOCATING CLIP R/H 1881 6 CASE 1922 3 CLIP 5230 7 LOCATING CLIP L/H 1882 4 SELF ADHESIVE ALUM SHEET 5333 1 Main Frame
More information1470 SERIES HOT AIR GAS BURNER
1 SERIES HOT AIR GAS BURNER CAPABILITIES High or low temperature furnace High excess air 800% or more Ratio or tempered flame operation Nominal capacity range 0,000 to 3.5 MM Btu/hour Suitable for light
More informationEclipse RatioAir Burners
Data 115-1 10/1/07 Eclipse RatioAir Burners Main Specifications - RA0 PARAMETER Maximum input, () at neutral chamber conditions 60Hz Packaged Maximum input, () at neutral chamber conditions 50Hz Packaged
More informationRL/M BLU SERIES. Low NOx Modulating Light Oil Burners FIRING RATES. LOW NOx T. M 190/ kw M 223/ kw
LOW NOx T The RL/M BLU burners series covers a firing range from 360 to 1023 kw, and it has been designed for use in hot or superheated water boilers, hot air or steam generators and diathermic oil boilers.
More informationM/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners
M/MR Modulating Valves design certified For Atmospheric, Infrared, and Direct Fired urners TALE OF CONTENTS Description/Specifications... 1 Introduction... 2 Direct Fired Applications (Negative Pressure)...
More information1466 SERIES COLD AIR GAS/OIL BURNER
CAPABILITIES High or low temperature furnace High excess air 800% or more Ratio or tempered flame operation Nominal capacity range 0,000 to 3.5 MM Btu/hour Suitable for light wall construction FEATURES
More informationYARWAY NARVIK VEN-TEMP DESUPERHEATER MODEL 25
Yarway covers requirements for Desuperheaters, pneumatic actuators, strainers with a wide range of models, sizes and materials to satisfy all the specifications of the power, pulp and paper industry and
More informationRatioAir Burners. Model RA0750. Data /31/05. Main Specifications - RA0750
Main Specifications - RA0750 PARAMETER Maximum input, Btu/hr (kw) at neutral chamber conditions. (Natural Gas) 60Hz Packaged 50Hz Packaged Minimum input, Btu/hr (kw) Lower inputs may be achieved. Contact
More informationInnovo Condensing high efficiency water heater
Condensing high efficiency water heater IR 12-160/20-160/12-200/20-200/24-245/32-245/ 24-285/32-285/32-380 A Fully room-sealed condensing high efficiency water heater Automatic gas/air premix burning system
More informationTriOx Triple Air Staged Ultra Low NOx Burner
Triple Air Staged Ultra Low NOx Burner TriOx-1 Edition 09-08 Ultra low NOx emissions of 20 ppm or less Invisiflame mode offers positive UV flame supervision throughout entire operating range for excellent
More informationXID ENHANCEMENT SYSTEM IMPROVED EFFICIENCY AND PERFORMANCE
IMMERSION FIRED HOT WATER BOILER April 1, 2003 GENERAL DESCRIPTION The Sellers immersion fired hot water boiler is a horizontal, single pass, firetube boiler designed to burn natural gas. The unique burner
More informationSPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model ACO. R EN - Edition 04-01/04/2008
SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model ACO R8215222-04EN - Edition 04-01/04/2008 Domestic Gas Boilers ACO 537060 ACO 27 MFFI MET...... 537061 ACO 27 MFFI GPL...... 537062 ACO 27 RFFI SYSTEM MET......
More informationSPARE PARTS LIST - July
Versions for CANADA SPARE PARTS LIST - July 2005 - HOW TO READ THE SPARE PARTS CATALOGUE In the spare part catalogue, after the exploded diagrams, there are the components lists of the boilers; this is
More informationRatioAir Burners. Model RA1000. Data /31/05. Main Specifications - RA1000
Main Specifications - RA1000 PARAMETER Maximum input, Btu/hr (kw) at neutral chamber conditions. (Natural Gas) 60Hz Packaged Blower 50Hz Packaged Blower Minimum input, Btu/hr (kw) Lower inputs may be achieved.
More informationControls and Accessories Part Number Controls and Accessories Part Number
Linea 24 Mark 1 Serial Number Up to 161380001 Controls and Accessories Part Number Controls and Accessories Part Number CLOCK - MECHANICAL 201 CLOCK - DIGITAL 202 CONVERSION KIT LPG - NG 01005225 CONVERSION
More informationV2000FS FS type TRV Body FINELY PRESETTABLE RADIATOR VALVE WITH FLUSH POSITION
V2000FS FS type TRV Body FINELY PRESETTABLE RADIATOR VALVE WITH FLUSH POSITION PRODUCT DATA Application 011 Angle to DIN Angle to NF Straight to DIN Straight to NF Thermostatic radiator valve bodies (TRV
More informationONE STAGE GAS BURNERS RDBS SERIES
ONE STAGE GAS BURNERS RDBS SERIES 16 47 kw RDBS.1 16 47 kw The Riello RDBS is a new series of one stage gas burners with integrated gas train, characterised by its small dimensions in spite of its high
More informationVKF41...C. Butterfly Valves. Building Technologies Division Industry Sector
7 62 Butterfly Valves VKF41...C Butterfly valves designed for fitting between counter-flanges, for integration into gas trains Disk with metallically tight shutoff DN40...DN200 Angle of rotation 85 No
More informationSentronic LP IO-Link CLASS A 617 Series. Proportional Technology
Sentronic LP IO-Link CLASS A 617 Series Proportional Technology PROPORTIONAL PRESSURE CONTROL: 617 SERIES SENTRONIC LP IO-LINK VERSION ASCO NUMATICS Sentronic LP The Sentronic LP is a highly efficient
More informationCombination controls CG 10
Combination controls CG 0... Edition 03. GB Combination controls CG 0 Complete with strainer, two solenoid valves and servo-governor for maximum regulation precision. Special low-noise valves. Optional
More informationDifferential Pressure Switch QBM81-
s 1 552 Differential Pressure Switch QBM81- for air and nonaggressive gases For ventilation and air conditioning plants To monitor air filters, air flow, fan belts To monitor pressure in clean rooms, kitchens
More information11A-1 ENGINE CONTENTS
11A-1 ENGINE CONTENTS ENGINE ENGINE ... 11A... 11B 11A-2 ENGINE CONTENTS GENERAL... 3 Outline of Changes... 3 GENERAL INFORMATION... 3 SERVICE SPECIFICATIONS... 3 SEALANT... 3 SPECIAL
More informationSPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model UNO. R EN - Edition 01-15/10/2007
SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model R8216080-01EN - Edition 01-15/10/2007 537255 24 MFFI (RO) MET...... 537256 24 MFFI (RO) GPL...... 537632 24 MFFI MET (PL, CZ, UCR)...... 537633 24 MFFI
More information3/2-way Solenoid Valve for pneumatics
656 3/-way Solenoid Valve for pneumatics Compact design Single and manifold mounting Low power consumption Rocker pilot in DC Type 656 can be combined with... Fast response times Type 506 Type 510/511
More informationError codes Diagnostic plug Read-out Reset Signal Error codes
Error codes Diagnostic plug Diagnostic plug: 1 = Datalink LED tester (FEN) 3 = activation error codes (TEN) 4 = positive battery terminal (+B) 5 = ground Read-out -Connect LED tester to positive battery
More informationQ5020A-D Globe Valve Linkages FOR DIRECT COUPLED ACTUATORS
Q5020A-D Globe Valve Linkages FOR DIRECT COUPLED ACTUATORS FEATURES PRODUCT DATA Used with 2- and 3- globe valves in modulating or two-position service. Used with 25, 50, and 142 lb-in. spring return and
More informationYarway Narvik Ven-Temp Desuperheater Model 25
Yarway covers requirements for Desuperheaters, pneumatic actuators, strainers with a wide range of models, sizes and materials to satisfy all the specifications of the power, pulp and paper industry and
More information3/2-way and 2 x 3/2-way Solenoid Valve for pneumatics
654 3/-way and x 3/-way Solenoid Valve for pneumatics Compact design Single and manifold mounting Low power consumption Fast response times Space saving ( x 3/-way version) Type 654 can be combined with...
More informationVLF45... Hot Air Valves. Siemens Building Technologies HVAC Products
7 637 Hot Air Valves VLF45... Single valve for use in the supply air line of heat generating equipment Valves used in connection with SKP... actuators open slowly and close rapidly 2-port valves of the
More informationSPARE PARTS EXPLODED VIEW GAS WALL BOILERS
SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS 27 BFFI PLUS Edition 4 Current from Serial No: 2320317800001 to: ------------------ Add to Edition 3 1 71 70 9 8 7 5 9 3 4 3 5 7 5 1 2 1 8 9 120 0
More informationPerformance. Perkins Engines Company Limited. Perkins Engines Company Limited. Peterborough PE1 5FQ United Kingdom Tel: +44 (0)
105 kwm (Gross) @ 1500 rpm ElectropaK 1100 Series Basic technical data Number of cylinders.....................................................4 Cylinder arrangement...................................
More informationDEUTZ Engine Documentation Genset Manual. BF4M2012C (D2OC74,9) - 50 Hz 1/5 DEUTZ AG
1/5 DEUTZ AG Technical data General engine data Engine Type BF4M2012C EKZ 11372 Speed 1500 min -1 Net frequency Exhaust emission standard 50 Hz Stage II Specific engine data Aspiration No of cylinders
More informationAir Cooler Industry AC-LN 8-14 / ACA-LN 8-11 / ACAF-LN 8-11
Air Cooler Industry AC-LN 8-14 / ACA-LN 8-11 / ACAF-LN 8-11 Symbol General The AC-LN 8-14 air cooler series can be used in all areas where either oil or water-glycol is to be cooled with air. The coolers
More informationLVDT/HC PILOT BURNER. External raw gas pilot burner
4-22.4-1 LVDT/HC PILOT URNER External raw gas pilot burner Stable pilot flame in combination with MXON IRFLO LV, HC, DELT-TE and COMUSTIFUME burners Rugged design urns natural gas, propane and LPG Suitable
More informationCOMBI OVENS SI EQUATOR 6 BUILDER S SPECIFICATIONS. Part C: Maintenance manual 3BE390691NM
EQUATOR 6 COMBI OVENS SI BUILDER S SPECIFICATIONS Part C: Maintenance manual - WARRANTY - In order to guarantee this equipment, we recommend that you comply with the MANUFACTURER S INSTRUCTIONS in this
More informationG76x Direct Spark Ignition Controls
Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin G76x Issue Date 0400 G76x Direct Spark Ignition Controls Figure 1: G76x Direct Spark Ignition
More informationUB95M-200 Gas-Fired Direct Vent Modulating Hot Water Boiler
UB9M-200 Gas-Fired Direct Vent Modulating Hot Water Boiler Repair Parts Manual Ordering Instructions Order Parts through your nearest supplier. When ordering parts, obtain Model Number and Serial Number
More informationDifferential-Pressure Flow Meter
Design and application The metering orifice measures and monitors the flow rate of liquids. The user mounts the orifice between flanges or with Rp screwed connections into the conduit. The unimpeded, straight
More informationV5003F Kombi-VX PRE-SETTABLE FLOW CONTROL VALVE
V5003F Kombi-VX PRE-SETTABLE FLOW CONTROL VALVE PRODUCT DATA 5 4 3 1 7 Application The V5003F Kombi-VX is an automatic balancing valve. It is designed for balancing of heating and cooling systems by providing
More informationM436A/M836A,B Damper Motors
M436A/M836A,B Damper Motors FEATURES INSTALLATION INSTRUCTIONS APPLICATION M436A/M836A,B Damper Motors are spring return (SR) motors used for residential and light commercial applications in Series 40
More informationDoing more for clean environment and energy saving
Doing more for clean environment and energy saving Rütli Burners Switzerland AG is a worldwide leading industrial burner solution supplier. Our head quarter is located in Schaffhausen, Switzerland one
More informationSpare parts catalogue GB 07/2008. Wall-hung boilers ecotec VU 466/4-5 VU 656/4-5
Spare parts catalogue 0020067960.02 GB 07/2008 Wall-hung boilers ecotec VU 466/4-5 VU 656/4-5 Content General view of sheet VU 466/4-5 Page 3 04 Burner Page 4 06 Heat exchanger Page 6 07 Casing parts
More informationFRM. Medium Pressure Regulator. Medium pressure regulator Type FRM
FRM Medium Pressure Regulator Medium pressure regulator Type FRM Direct acting pressure regulator with adjustable setpoint springs and modular mounted safety shutoff valve (SAV) In compliance with EN 334
More informationSPARE PARTS CATALOGUE
SPARE PARTS CATALOGUE - October 2015 - HOW TO READ THE SPARE PARTS CATALOGUE In the spare part catalogue, after the exploded diagrams, there are the components lists of the boilers; this is the meaning
More informationNOx-Beta Ultra Low NOx Burners
NOx-Beta Ultra Low NOx s February NOx-Beta Features Ultra low NOx without any performance loss Staged air principle no external NOx reducing devices or FGR needed Robust, well engineered construction Cost
More informationWeishaupt gas burners Sizes 30 to 70 Version NR (NO x reduced)
Weishaupt gas burners Sizes 30 to 70 Version NR (NO x reduced) Description Weishaupt industrial burners, sizes 30 to 70, have been especially designed for industrial capacity ranges. The monobloc burners
More informationSPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model ACO. R EN - Edition 06-01/12/2010
SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model ACO R8215222-06EN - Edition 06-01/12/2010 Domestic Gas Boilers ACO 537060 ACO 27 MFFI MET...... 537061 ACO 27 MFFI GPL...... 537062 ACO 27 RFFI SYSTEM MET......
More informationBGD258 Series BASOTROL CE Approved Class A Gas Valve
Product Bulletin Issue Date May 21, 2010 BGD258 Series BASOTROL CE Approved Class A Gas Valve The BGD258 Series multi-function gas control valve works in conjunction with an electronic sequence control
More informationNARVIK-YARWAY. Heavy Duty A.T. - Temp Desuperheater Model: 18/54 and 28/64
NARVIK-YARWAY Narvik-Yarway covers requirements for Desuperheaters, pneumatic actuators, strainers with a wide range of models, sizes and materials to satisfy all the specifications of the power-pulp &
More informationFigure 1-1(d) Tft Installation Kit
TRINITY TFT60-399 PARTS LIST For a list of parts that corresponds to the item numbers in the callouts, refer to Table 1-1. Note that some item numbers may appear more than once in the parts list depending
More informationProduct Information. Model: LNVG, LNVLG Burner Sizes: 13, 15, 17, 20, 21, 25 GENERAL DESCRIPTION U.L. STANDARD EQUIPMENT
The LNV/Series gas, oil, and combination gas/oil burner is a forced draft packaged burner system. A balanced blower wheel mounted in a fabricated housing provides combustion air for various furnace pressures
More informationGasBloc Multifunctional gas control Combined regulator and safety shut-off valves Electrically modulating GB-M(P) 057 D01
Gasloc Multifunctional gas control Combined regulator and safety shut-off valves Electrically modulating G-M(P) 057 D01 Two stage operating mode G-(LEP)Z 057 D01 Technical Description Multifunctional gas
More informationG600 Series Replacement Intermittent Pilot Ignition Controls
Installation Instructions G600 Issue Date 0601 G600 Series ment Intermittent Pilot Ignition Controls Installation IMPORTANT: These instructions are intended as a guide for qualified personnel installing
More information