S4562C 1085 COMBI BOARD APPLICATION. Contents PRODUCT HANDBOOK. General

Size: px
Start display at page:

Download "S4562C 1085 COMBI BOARD APPLICATION. Contents PRODUCT HANDBOOK. General"

Transcription

1 S4562C 1085 COMBI BOARD APPLICATION PRODUCT HANDBOOK The S4562C 1085 combi board is an integration of an on/off temperature control and an electronic ignition control. The S4562C 1085 combi board is intended for use in a fan assisted combi boiler with direct burner ignition for non permanent operation. The S4562C 1085 combi board is intended for use with a VK4105 gas valve. The S4562C1085 combi board uses a sensor equivalent to the T7335 temperature sensor. The temperature setpoint can be set with a potmeter. The S4562C 1085 combi board can be used in appliances according European standards for household electrical requirements EN For glossary of terms, abbrevations and symbols, see document EN2R Subject to change without notice. Printed in the Netherlands. General Contents Description... 2 Features... 3 Technical Dimensional drawing... 4 Specifications... 5 Specifications logic control... 7 System operation... 8 Timing diagram... 9 Installation, adjustment and checkout Various Tolerances and product life EMC guidelines Quality assurance statement Approvals and standards Ordering information... 12

2 DESCRIPTION The S4562C 1085 combi board is a combination of an on/off temperature control with electronic ignition, pump control, mid position valve control, transformer, fuse(s) and a wiring centre at Printed Circuit Board (PCB) When the S4562C 1085 combiboard is energized by the central heating thermostat (CH--mode), the igniter is controlled depending on the temperature setting of the potmeter and the temperature sensor. If the flow switch detects a flow rate (DHW--mode), the igniter is also controlled depending on the temperature setting and temperature sensor. 2

3 FEATURES Logic control Potmeter for temperature control. Off position of potmeter. LED indication for power on. Suitable for both Y--plan and S--plan systems. Pump overrun. Ignition control Hybrid technology for high reliability. Flame supervision. Built in 25 Hz ignition. Internal reset. Accurate safety timer. Full operating sequence after flame loss. Non volatile lock--out according to EN 298. EMC filter. Protective impedance flame rod. Under voltage protection. 3

4 DIMENSIONAL DRAWING 179 Flame detection X 7 X 9 X (5x) 10 Earth connection X 10 X 11 X 12 S 1 Reset switch L 1 P Flow switch Mid valve S 101 Y pos S pos Timer Y plan S plan Temperature setting X 1 X L N Ls Lr N 7 Room thermostat Froststat X 3 4 X X 5 X Line voltage DBI gas valve High Limit Fan Pump APS Sensor T7335 Fig. 1. Dimensional drawing and connections 4

5 SPECIFICATIONS Model S4562C 1085 electronic interface system for fan assisted combi boilers with direct burner ignition. Dimensions See fig 1. page 4 Supply voltage 230 Vac, 50 Hz Power consumption PCB 6VA Electrical rating Mains input Supply voltage: 230 Vac (+10 %/--15 %), 50 Hz Max. power rating: 460 VA Fusing: 4 A Pump output Power rating: 120 VA Minimum cos :0.6 Gas valve Output voltage: 230 V rectified (+10 %/--15 %), 50 Hz Power rating: VA High limit control Output voltage: 230 V rectified (+10 %/--15 %), 50 Hz Power rating: VA Mid valve position Power rating: 120 VA Minimum cos :0.6 Timer control Power rating: VA Room thermostat Current rating: < 1mA Flow switch Current rating: < 1mA Frost stat Current rating: < 1mA Fan output Power rating: 120 VA Minimum cos :0.6 Air pressure switch Output voltage: 24 Vdc (+10 %/--15 %) Power rating: 0.5 VA Temperature sensor Output voltage: 6 Vdc (+10 %/--15 %) Electrical connection (see table 1. page 5 and fig. 1. page 4) The combi board accepts Molex connector 3069 series (ordernumber XX00) with crimp terminals of the 2478 series. The combi board accomodates polarising key type Table 1. Connection Status Range Type Mains supply Input 230 Vac Srew connector Room thermostat Input 230 Vac Srew connector Flow switch Input 230 Vac Stelvio Frost switch Input 230 Vac Srew connector Temperature sensor Air pressure switch Input Molex Input 24 Vdc Molex Fan Output 230 Vac Molex Pump Output 230 Vac Molex Mid valve Output 230 Vac Stelvio Timer Output 230 Vac Stelvio Gas valve Output 230 V rectified High limit control Molex Input 230 Vac Molex Earth Input Tinned area on PCB that contacts a metal spring Flame sensing Input 230 Vac high source impedance Ignition Output > 12 kv at 12 pf load Timing Self check time (T c ): 2.2 s Safety time (T s ): 10 s Extended spark ignition time: 0 s Flame sensing Min flame current: 0.9 A Response time on: > 0.2 s Response time off (T FR ): < 1. s (at I FLAME <2 A) Maximum length of flame sensing cable: 1 m Ignition Spark voltage: >12 kv at 40 pf load Spark frequency: 25 Hz Spark energy: 3 As. Maximum spark gap: 3.5 mm Maximum length of ignition cable: 0.5 m 6.3 mm spade terminal 2.8 mm spade terminal 5

6 Mounting The printed circuit board offers a means for direct mounting as a bare board. The printed circuit board has five mounting holes with a diameter of 4 mm. The combi board has to be placed in a clean situation according to EN The air pressure switch, sensor, potmeter and flame sensing connection are safely accessible according to EN If the ignition frequency is 25 Hz, the ignition cable and its connections shall have a protection against electrical shock hazard. The reset switch and all other connections are inside the boiler and therefore not accessible. The printed circuit board should be mounted in an enclosure that provide the correct creepage and clearance distances. The combi board has to be mounted by means of insulated spacers. Environmental conditions Free air operating temperature range inside the housing: _C Ambient operating humidity: 95% at 40 _C (non condensing) Storage temperature: _C 6

7 SPECIFICATIONS LOGIC CONTROL General Temperature sensor equivalent to T7335 type, R 25 = Ohm. All specified temperatures are based on the nominal temperature sensor characteristic. DHW--mode has priority above CH--mode. DHW- mode Temperature setting (P 1 ) Maximum switch off point: 86 _C (± 2.5 _C) Maximum switch on point: 63 _C (± 2.5 _C) Minimum switch off point: 60 _C (± 2.5 _C) Minimum switch on point: 36 _C (± 2.5 _C) Pump overrun During DHW--mode the pump is on. After DHW heat demand there is a pump overrun time. Pump overrun time: 180 s (± 25%). Temperature sensor break The combi board shall de--energize the igniter when the temperature sensor is in high resistance state. High resistance state is activated at temperature sensor resistance higher than >50 k. CH- mode Temperature setting (P 1 ) Maximum switch off point: 86 _C (± 2.5 _C) Maximum switch on point: 63 _C (± 2.5 _C) Minimum switch off point: 60 _C (± 2.5 _C) Minimum switch on point: 36 _C (± 2.5 _C) Pump overrun During CH--mode the pump is on. After CH heat demand there is a pump overrun time. Pump overrun time: 180 s (± 25%). Temperature sensor break The combi board shall de--energize the igniter when the temperature sensor is in high resistance state. High resistance state is activated at temperature sensor resistance higher than >50 k. 7

8 SYSTEM OPERATION Logic control general description Power indication There is a LED L1 (green) placed at the printed circuit board for power indication. If the mains supply is present, the LED L1 is on. S/Y plan With the slide switch mounted at the copperside of the printed circuit board it is possible to switch from Y plan to S plan. This is the Sundial plan system Disable function With potmeter P1 at minimum position it is possible to disable the combi board. It is not possible to get DHW--mode or CH--mode. During pump overrun time it is possible to disable the combi board, but the pump is still running during its overrun time. After this the combi board is disabled. RY101 Disable Enable Fig. 2. Logic control Domestic Hot Water (DHW) mode When DHW--mode id detected as a result of detecting flow rate, the pump is on and the gas valve is controlled, depending on the input signal of the temperature sensor. The S4562C 1085 has an on/off temperature control. The temperature is set by the potmeter P 1. After heat demand the pump stays on for a certain time (pomp overrun time). P 1 Logic control Central Heating (CH) mode When the room thermostat is energised (CH--position), the operation is identical to DHW--mode. The pump is on. The temperature can be adjusted by the potmeter P 1. The S4562C 1085 has an on/off temperature control. After heat demand the pump stays on for a certain time (pomp overrun time). Ignition control General The combi board provides closed loop sparking. Program run (see fig. 3.) When the logic control generates a call for heat, a self check period (T c ) elapses when the air proving switch (APS) is in the no air position. After the self check period (T c ) the fan starts running. When sufficient air flow is proven by the air proving switch (APS), the built in igniter and the gas valves are switched on. The ignition spark ignites the gas and the resulting flame is detected by the flame rod. If flame is not established within the safety time (T s ), the S4562C 1085 locks--out. If the flame is lost during normal run, the S4562C 1085 repeats the start sequence. If no air flow is proven by the air proving switch (APS), the ignition control stays in waiting mode. If the limiter opens during run, the gas valves close and the start sequence is repeated. The S4562C 1085 will lock--out since no flame will be detected. NOTE: If an automatic return high limit thermostat is used, it should have a return time that is longer than the safety time, otherwise the combi board will not lock--out. Reset from lock- out The combi board can be reset from the lock--out state by pressing the reset button S 1. NOTE: If during normal run the reset button is pressed, the gas valves close and the S4562C 1085 starts a new sequence after releasing the reset button. NOTE: When first starting, the combi board can be in the lock--out condition; reset the combi board. If a first reset is not successful, wait at least 15 seconds before attempting another try. NOTE: After a reset an extended waiting time will occur. 8

9 TIMING DIAGRAM P t 0 t 1 t 2 t 3 t 4 t 5 t 6 t 7 t 8 t 9 t 10 T c T ext T FR T c T s Legend t 0 -- Heat demand t 1 -- Fan starts running t 2 -- Air flow is proven, ignition trial t 3 -- Flame established t 4 -- Ignition stops t 5 -- Flame failure t 6 -- Flame failure response t 7 -- Air flow stopped, new start t 8 -- Fan starts running t 9 -- Air flow is proven, ignition trial t End of safety time: lock--out Fig. 3. Timing diagram ignition part 9

10 INSTALLATION, ADJUSTMENT AND CHECKOUT WARNING Take care that installer is a trained experienced service person. Disconnect power supply to prevent electrical shock and/or equipment damage. Turn off gas supply before starting installation. After installation wait at least one hour before connecting the mains supply, because the device can become wet due to condensation. Do not connect wet device to mains IMPORTANT Before installing or replacing any control check that type number is correct for the application. Ensure combustion chamber is free of gas before start up. Conduct a thorough check out when installation is completed. At the first start the combi board can be in lock -out; push the reset button to free control. CAUTION Do not connect the combi board to the mains when it is not connected to the gas control. Wiring IMPORTANT Wiring must be in accordance with local regulations. The appliance manufacturer s instructions should always be followed. If such instructions are not provided see fig.1. page 4 Use cable which can withstand 105 _C ambient. Use cable which is proven against moisture. Wiring between combi board and spark probe must be suitable for the temperatures encountered. Wiring between combi board and spark probe must have a minimum isolation resistance to earth of 500M under all working conditions. Wiring between combi board and flame sensing probe must be one piece without means for interrupting. CAUTION The ignition cable and its connections shall have a protection against electrical shock hazard. Fuses The combi board is internally fused with a2aslowfuse. NOTE: The ignition control has integrated fuse tracks that may not be replaced by any means. Spark gap Maximum allowable spark gap is 3.5 mm High voltage Make sure that the clearance and creepage distance from any metal parts of the high voltage connection to earth metal is more than 12 mm. Supply voltage polarity If the combi board seems to operate normally but does not detect flame, check for right polarity of the power supply line and neutral connections. Checkout Checking flame current The minimum value should be in accordance with specified value. To check flame current connect a dc micro--ampèremeter between flame sensing wire and flame sensing rod. Meter connections polluted with e.g. alkaline substances lying close to earth can cause flame current simulation. Make sure no false flame current can flow from meter connections to earth. If flame current is insufficient check that flame sensing rod is fully enveloped by the flame and that burner is reliable grounded to ignition control. If there is no sufficient flame current due to phase--phase mains it is recommended to use an AT7030A or AT7030B flame detection transformer. See also instruction sheet EN1R of the AT7030 transformer. Final checkout of the installation Set appliance in operation after any adjustment and observe several complete cycles to ensure that all components function correctly. WARNING Honeywell is not responsible for damage and/or injury due to miswiring. 10

11 TOLERANCES AND PRODUCT LIFE Ignition Under voltage disabling limit: 173 V ± 10 Vac No flame current: < 0.45 A Reliability The combi board must withstand at least cycles In order to ensure long term operation, mount the combi board at a position in the appliance where ambient temperature and heat radiation is low. High temperature will affect product life. EMC GUIDELINES The electronic ignition is a source of mains interference and radio frequency interference (RFI). In order to minimise RFI, do not lead the ignition wires close to mains wires. Twist the wires and position them close to earth metal. QUALITY ASSURANCE STATEMENT Products are manufactured under an ISO 9001 (1994) based and certified Quality System. The quality system is described in the Honeywell Combustion Controls Center Quality Assurance Programme and its related operational procedures and instructions. The quality system is approved by Gastec against certificate number 9.302/2. The quality organisation is responsible for defining, maintaining, improving and verification of the quality systems in the field of design, production process and field quality service. Assembly processes are guided by work instructions. Patrol inspections form part of the assembly processes. Assembly inspection is performed by employees of the quality control department, using their own authorised equipment. All inspections (incoming and assembly) are performed by trained personel and according inspection procedures. STANDARDS AND APPROVALS Standards The combi board meets the european standards: EN :Automatic electrical controls for household and simular use. EN 55014: Emission requirement for household appliances and portable tools. EN 55104: Immunity requirements for household appliances, tools and similar apparatus. The ignition control meets the european standard: EN 298: Automatic gas burner control systems. Regarding electrical safety, the combi board can be used in appliances according to european standard for household electrical requirements EN series. The S4562C 1082 combi board functions in accordance with EN 298 clause 4 code F/M/C/L/X/N. Approvals The combi board conforms with the following EC -- Directives: Gas Appliance Directive (90/396/EEC) Low Voltage Directive (73/23/EEC) Electro Magnetic Compatability Directive (89/336/EEC) 11

12 ORDERING INFORMATION Identification of device The identification of the device is by Honeywell Ordering Specification (O.S.) number and date code. Packing The combi boards shall be packed in a carton box according to the Honeywell standards. When ordering specify: Model number of combiboard. Order numbers of replacement parts and accessories required. Home and Building Control Combustion Controls Center Europe Honeywell BV Phileas Foggstraat AJ Emmen The Netherlands Tel: +31 ( -) Fax: +31 ( -)

S4565, S4575 AND S4585

S4565, S4575 AND S4585 S4565, S4575 AD S4585 IGITIO COTROLS FOR COMBIED VALVE AD IGITIO SYSTEM APPLICATIO PRODUCTIO HADBOOK The Combined Valve and Ignition (CVI) system has been developed for application in gas fired domestic

More information

AQUASTATS THERMOSTAT APPLICATION

AQUASTATS THERMOSTAT APPLICATION AQUASTATS THERMOSTAT APPLICATION PRODUCT HANDBOOK The L41../L61.. series aquastats are primarily designed for application on water filled heating systems and systems for hot water supply, mainly domestic

More information

G72x Series Direct Spark Ignition Controls

G72x Series Direct Spark Ignition Controls Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin G72x Issue Date 1299 G72x Series Direct Spark Ignition Controls Figure 1: G72x Direct Spark Ignition

More information

G821L/G822L Series Integrated Function Direct Spark Ignition Controls

G821L/G822L Series Integrated Function Direct Spark Ignition Controls Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin G821L/G822L Issue Date 1199 G821L/G822L Series Integrated Function Direct Spark Ignition Controls

More information

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION VQ400M SERIES PRODUCT HANDBOOK APPLICATION The VQ400M Series class A safety combination valves are used for control and regulation of gaseous fluids in gas power burners, atmospheric gas boilers, melting

More information

Honeywell VV, VP, VB & MS SERIES FOR VQ400M CLASS A VALVES PRODUCT HANDBOOK APPLICATION

Honeywell VV, VP, VB & MS SERIES FOR VQ400M CLASS A VALVES PRODUCT HANDBOOK APPLICATION Honeywell VV, VP, VB & MS SERIES FOR VQ400M CLASS A VALVES PRODUCT HANDBOOK APPLICATION The VV Series class A vent valves are intended to be used in combination with the VQ400M series combination valve.

More information

G76x Direct Spark Ignition Controls

G76x Direct Spark Ignition Controls Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin G76x Issue Date 0400 G76x Direct Spark Ignition Controls Figure 1: G76x Direct Spark Ignition

More information

Electronic Ignition Equipment

Electronic Ignition Equipment 7 608 Electronic Ignition Equipment TQG3 The TQG3 consists of a cable for connection to the safety shutoff valves of the VGU gas valves and electronic ignition equipment for use on gas boilers with single-

More information

VE4000 & VE5000 SERIES

VE4000 & VE5000 SERIES VE4000 & VE5000 SERIES CLASS "A" GAS VALVES PRODUCT HANDBOOK APPLICATION These series class A gas valves are used for control and regulation of gaseous fluids in gas power burners, atmospheric gas boilers,

More information

VR400/VR800 series UNIVERSAL GAS VALVES CLASS A SERVO REGULATED COMBINATION VALVES APPLICATION. Contents PRODUCT HANDBOOK. General

VR400/VR800 series UNIVERSAL GAS VALVES CLASS A SERVO REGULATED COMBINATION VALVES APPLICATION. Contents PRODUCT HANDBOOK. General UNIVERSAL GAS VALVES VR00/VR800 series CLASS A SERVO REGULATED COMBINATION VALVES APPLICATION PRODUCT HANDBOOK The VR00 Series class A servo regulated combination valves are used for control and regulation

More information

Boiler Management Unit (BMU)

Boiler Management Unit (BMU) 7 495 Boiler Management Unit (BMU) LMU74... LMU75... LMU7 are digital Boiler Management Units (BMUs) for use in gas-fired appliances equipped with premixing burners. LMU74 without combustion optimization

More information

burners with or without fan. It conforms to EN C). APPROVAL EU type test approval as per EU Gas Appliance Directive.

burners with or without fan. It conforms to EN C). APPROVAL EU type test approval as per EU Gas Appliance Directive. LAST UPDATE 29/08/12 INSTALLATION INSTRUCTIONS v. 3 UNIT SPECIFICATIONS Main Gas Valve, Pilot Gas Valve Ionisation, Ignition and Flame Monitoring with Common Electrode or Remote Sensor Integrated Cyclic

More information

E Series CE Approved Intermittent Pilot Ignition Control

E Series CE Approved Intermittent Pilot Ignition Control Installation Instructions Issue Date January 11, 2013 E Series CE Approved Intermittent Pilot Ignition Control Application The E Series CE Approved Intermittent Pilot Ignition Control is a safety control

More information

G861 Series Integrated Function. Direct Spark Ignition Control

G861 Series Integrated Function. Direct Spark Ignition Control Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin G861 Issue Date 0699 G861 Series Integrated Function Direct Spark Ignition Control Figure 1:

More information

AQUASTATS THERMOSTAT APPLICATION CONTENTS PRODUCT HANDBOOK

AQUASTATS THERMOSTAT APPLICATION CONTENTS PRODUCT HANDBOOK AQUASTATS THERMOSTAT PRODUCT HANDBOOK APPLICATION The L41../L61.. series aquastats are primarily designed for application on water filled heating systems and systems for hot water supply, mainly domestic

More information

SERIES VAC Microprocessor Based Direct Spark Ignition Control FEATURES DESCRIPTION APPLICATIONS THE TOTAL SOLUTION FOR GAS IGNITION CONTROL

SERIES VAC Microprocessor Based Direct Spark Ignition Control FEATURES DESCRIPTION APPLICATIONS THE TOTAL SOLUTION FOR GAS IGNITION CONTROL SERIES 35-72 120 VAC Microprocessor Based Direct Spark Ignition Control 35.72.03 FEATURES Two Mounting Configurations Open Board With Stand-Off's - saves space and cost Potted - protection for washdown

More information

G600 Series Replacement Intermittent Pilot Ignition Controls

G600 Series Replacement Intermittent Pilot Ignition Controls Installation Instructions G600 Issue Date 0601 G600 Series ment Intermittent Pilot Ignition Controls Installation IMPORTANT: These instructions are intended as a guide for qualified personnel installing

More information

MS Application. Features. Proportional Valve Actuator General Instructions

MS Application. Features. Proportional Valve Actuator General Instructions Proportional Valve Actuator Application The Proportional Valve Actuator is a non-spring return actuator used with proportional to 10 Vdc or 4 to 0 ma controllers and standard 1/" to 1-1/4" two-way and

More information

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW Page 1 of 6 3-Phase Panel Mount 86 and 105kW Features: Benefits: 0-10Vdc, 0-5Vdc, 4-20mA or manual via potentiometer control input Over temperature protection with auto reset Enclosed panel mounting Efficient

More information

/

/ 45.900.444-/45.900.446- VENTURI MANIFOLD FOR VK41.5V/VK81.5V GAS CONTROLS PRODUCT HANDBOOK APPLICATION The venturi manifold combined with the VK41.5V/VK81.5V gas controls and a specific DC-fan is called

More information

Series P215ST Single Pressure Input Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter)

Series P215ST Single Pressure Input Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter) PSC9733 European Refrigeration Controls Catalogue Catalog Section 4 Product Bulletin Series Single Pressure Input Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression

More information

Q35 Series Automatic Vent Damper System

Q35 Series Automatic Vent Damper System Installation Sheets Manual 121 Energy Conservation and Miscellaneous Kits Section Q Technical Bulletin Q35 Issue Date 0999 Q35 Series Automatic Vent Damper System Figure 1: Q35 Automatic Vent Damper System

More information

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD Dycon D1532SM EN50131/PD6662 Grade 3, 12V 2A Power Supply Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD Tel: +44 (0)1443 471 900 Unit A Cwm Cynon Business Park Mountain

More information

ORDERING INFORMATION SPECIFICATIONS APPLICATION

ORDERING INFORMATION SPECIFICATIONS APPLICATION ORDERING INFORMATION UNIVERSAL MODELS The ordering part number for the universal model is 82UNIVERSAL. The 82UNIVERSAL comes with remote flame sense active. For internal flame sense, the supplied universal

More information

Phoenix Inverter

Phoenix Inverter Manual EN Handleiding NL Manuel FR Anleitung DE Manual ES Appendix Phoenix Inverter 12 250 12 375 12 500 12 800 24 250 24 375 24 500 24 800 48 250 48 375 48 500 48 800 1. Safety instructions WARNING: ELECTRIC

More information

Series P255MM/ML Single/Dual Pressure Input Condenser Fan Speed Controllers For Three Phase Motors (incl. built-in RFI suppression filter)

Series P255MM/ML Single/Dual Pressure Input Condenser Fan Speed Controllers For Three Phase Motors (incl. built-in RFI suppression filter) PSC 0108 European Refrigeration Controls Catalogue Catalog Section 4 Product Bulletin Series Single/Dual Pressure Input Condenser Fan Speed Controllers For Three Phase Motors (incl. built-in RFI suppression

More information

- Wiring Brochure Universal Reset Module 422

- Wiring Brochure Universal Reset Module 422 - Wiring Brochure Universal Reset Module 422 W 422 03/09 1 Information Brochure hoose controls to match application Application Brochure Design your mechanical applications 2 3 Rough-in Wiring Rough-in

More information

c-go 24V/6A 24V/8A 24V/12A

c-go 24V/6A 24V/8A 24V/12A c-go 24V/6A 24V/8A 24V/12A Battery charger GB Instruction manual 1 Index 1. Product description... 2 2. Safety advices... 3 3. Quick start guide... 4 4. Operation... 4 5. Problem solving... 6 6. Specifications...

More information

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL 72-6850 & 72-6852 HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL Table of Contents Introduction 2 Specification 2 Safety 4 EMC 5 Installation 6 Connections 6 Operation 7 Maintenance and Repair 8 www.tenma.com

More information

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

Dycon D2430 EN54-4 Fire Alarm Power Supply Series Dycon D2430 EN54-4 Fire Alarm Power Supply Series Technical Description Installation and Operating Manual Construction Product Regulation 0359-CPR-00434 Page 1 of 14 Contents 1. General... 3 1.1 Product

More information

MA-5200 Series MA-5300 Series

MA-5200 Series MA-5300 Series MA-5200 Series MA-5300 Series Two-Position Actuators General Instructions Application The MA-5200 series and MA-5300 series actuators are used for two-position control of valves and dampers which require

More information

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz GR24A-5 / -7 GR24A-5 Rotary actuator for rotary valves GR24A-7 Rotary actuator for rotary valves Nominal torque 40Nm Nominal voltage AC/DC 24V Control Open-close echnical data Electrical data Nominal voltage

More information

Elmdene International Ltd

Elmdene International Ltd 1 Elmdene International Ltd Tel: +44(0)23 9269 6638 3 Keel Close, Interchange Park, Fax: +44(0)23 9266 0483 Portsmouth, Hampshire, PO3 5QD, UK Web: www.elmdene.co.uk 13.8Vdc Switch Mode Power Supply GEN3-08-y

More information

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS 013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS FOR OVERHEAD NETWOKS CEYLON ELECTRICITY BOARD SRI LANKA Specification for MOULDED CASE CIRCUIT BREAKERS FOR OVERHEAD NETWOKS CEB Specification

More information

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION VQ400M SERIES PRODUCT HANDBOOK APPLICATION The VQ400M Series class A safety combination valves are used for control and regulation of gaseous fluids in gas power burners, atmospheric gas boilers, melting

More information

Modulating Furnace Information. Warning on Meter Setting - Read First!

Modulating Furnace Information. Warning on Meter Setting - Read First! Modulating Furnace Information Pressure Transducer Pressure DC Volts 0.00" 0.25 0.20" 0.63 0.25" 0.72 0.30" 0.82 0.35" 0.91 0.40" 1.00 0.45" 1.09 0.50" 1.19 0.55" 1.28 0.60" 1.38 0.65" 1.47 0.70" 1.56

More information

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model ACO. R EN - Edition 04-01/04/2008

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model ACO. R EN - Edition 04-01/04/2008 SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model ACO R8215222-04EN - Edition 04-01/04/2008 Domestic Gas Boilers ACO 537060 ACO 27 MFFI MET...... 537061 ACO 27 MFFI GPL...... 537062 ACO 27 RFFI SYSTEM MET......

More information

ONE STAGE GAS BURNERS RDBS SERIES

ONE STAGE GAS BURNERS RDBS SERIES ONE STAGE GAS BURNERS RDBS SERIES 16 47 kw RDBS.1 16 47 kw The Riello RDBS is a new series of one stage gas burners with integrated gas train, characterised by its small dimensions in spite of its high

More information

MF /MS Series

MF /MS Series MF41-6153/MS41-6153 Series 24 Vac, Three-position/Modulating Non-spring Return Rotary Electronic Damper SmartX Actuators General Instructions Description The direct-coupled, 24 Vac, non-spring return electronic

More information

CX-SERIES ADVANCED BATTERY CHARGER

CX-SERIES ADVANCED BATTERY CHARGER CX-SERIES ADVANCED BATTERY CHARGER Table of Content 1. IMPORTANT SAFETY INFORMATION... 2 1-1 General Safety Precautions... 2 1-2 Battery Precautions... 2 2. FEATURES... 3 2-1 Battery Charging Curve...

More information

BellMega BM-510. Operation Manual Ver: 1.0 Rev: 1

BellMega BM-510. Operation Manual Ver: 1.0 Rev: 1 BellMega BM-510 Operation Manual Ver: 1.0 Rev: 1 CONTENTS Page Description 1 Operation 2 Safety 2 Charging 3 Service / Calibration 3 Specifications 4 Description The BellMega is a continuity tester for

More information

BG1600M Intermittent Pilot Ignition Control

BG1600M Intermittent Pilot Ignition Control Installation Instructions Issue Date March, 00 BG600M Intermittent Pilot Ignition Control Application The BG600M Intermittent Pilot Ignition Control is a safety control designed for indirect burner ignition

More information

EC7830A, RM7830A, EC7850A, RM7850A 7800 SERIES Relay Modules

EC7830A, RM7830A, EC7850A, RM7850A 7800 SERIES Relay Modules EC7830A, RM7830A, EC7850A, RM7850A 7800 SERIES Relay Modules INSTALLATION INSTRUCTIONS APPLICATION The Honeywell EC/RM7830A and EC/RM7850A are microprocessor-based integrated burner controls for automatically

More information

Circuit Board Diagnostics

Circuit Board Diagnostics Circuit Board Diagnostics NOTE: Discharge your body s static electricity before touching unit. An electrostatic discharge can adversely affect electrical components. Troubleshoot Integrated Control Module

More information

INSTALLER MANUAL USER MANUAL. Contents

INSTALLER MANUAL USER MANUAL. Contents Installation & user manual two way Contents INSTALLER MANUAL Important information General 1. Technical data 2. Description Installation: 1. Positioning the unit 2. Connection. 3. Parts description. 4.

More information

Multi-Mover Charger for model L25

Multi-Mover Charger for model L25 Multi-Mover Charger for model L25 Important safety instruction. Keep these instructions. This manual contains important instructions for the safety of the user and the operation of the device. 1. SYMBOLS

More information

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN SYMBOL LEGEND DANGER THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN WARNING THIS WARNS THAT MATERIALS MAY BE DAMAGED IF APPROPRIATE PRECAUTIONS ARE NOT

More information

VC2, VC4, VC60, VC8 ON-OFF ACTUATOR FOR VC SERIES BALANCED HYDRONIC VALVES SPECIFICATIONS INSTALLATION INSTRUCTIONS

VC2, VC4, VC60, VC8 ON-OFF ACTUATOR FOR VC SERIES BALANCED HYDRONIC VALVES SPECIFICATIONS INSTALLATION INSTRUCTIONS ON-OFF ACTUATOR FOR VC SERIES BALANCED HYDRONIC VALVES INSTALLATION INSTRUCTIONS Power consumption: 6 Watts Max. at nominal Voltage (during valve position change). Use 24 V Class 2 transformer and provide

More information

TWO STAGE PROGRESSIVE AND MODULATING GAS BURNERS RIELLO 40 GS/M SERIES GS 10/M 22/ kw GS 20/M 43/ kw

TWO STAGE PROGRESSIVE AND MODULATING GAS BURNERS RIELLO 40 GS/M SERIES GS 10/M 22/ kw GS 20/M 43/ kw TWO STAGE PROGRESSIVE AND MODULATING GAS BURNERS RIELLO GS/M SERIES GS /M / 5 3/8 19 The Riello GS/M series of two stage progressive or modulating gas burners, is a complete range of products developed

More information

MP-5400 Series. Application. Features. Applicable Literature. Electronic Positive Positioning Hydraulic Actuator General Instructions

MP-5400 Series. Application. Features. Applicable Literature. Electronic Positive Positioning Hydraulic Actuator General Instructions TAC 1354 Clifford Avenue P. O. Box 2940 Loves Park, IL 61132-2940 www.tac.com MP-5400 Series Electronic Positive Positioning Hydraulic Actuator General Instructions Application The MP-5400 Series Actuators

More information

B21 Series BASOTROL Gas Valve

B21 Series BASOTROL Gas Valve Installation Instructions B21 Issue Date September 19, 2017 Installation IMPORTANT: These instructions are intended as a guide for qualified personnel installing or servicing BASO Gas Products. Carefully

More information

822 NOVAMIX GAS FLOW RATE ADJUSTMENT AS A FUNCTION OF THE AIR FLOW GAS/AIR RATIO 1:1 DOUBLE AUTOMATIC SOLENOID SHUT-OFF VALVE

822 NOVAMIX GAS FLOW RATE ADJUSTMENT AS A FUNCTION OF THE AIR FLOW GAS/AIR RATIO 1:1 DOUBLE AUTOMATIC SOLENOID SHUT-OFF VALVE SIT Group 822 NOVAMIX MULTIFUNCTIONAL GAS CONTROL GAS FLOW RATE ADJUSTMENT AS A FUNCTION OF THE AIR FLOW GAS/AIR RATIO 1:1 DOUBLE AUTOMATIC SOLENOID SHUT-OFF VALVE SERVO-CONTROLLED PRESSURE REGULATOR PIN

More information

USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG SKYLLA 24/100 3-PHASE CE

USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG SKYLLA 24/100 3-PHASE CE USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG SKYLLA 24/100 3-PHASE CE SECTIONS: ENGLISH 2 NEDERLANDS 17 DEUTSCH 37 Victron Energy BV De Paal 35 1351 JG Almere-Haven The Netherlands Article number

More information

Emergency lighting units EM converterled. EM converterled BASIC 200 V BASIC series

Emergency lighting units EM converterled. EM converterled BASIC 200 V BASIC series EM converter EM converter BASIC 200 V BASIC series Product description lighting Driver for manual testing For modules with a forward voltage of 50 200 V ow profile casing (21 x 30 mm cross-section) For

More information

INDUSTRIAL CHARGER AUTOMATIC BATTERY CHARGER SERIES 150 KUSSMAUL ELECTRONICS CO., INC. MODEL # XX YEAR WARRANTY INSTRUCTION MANUAL

INDUSTRIAL CHARGER AUTOMATIC BATTERY CHARGER SERIES 150 KUSSMAUL ELECTRONICS CO., INC. MODEL # XX YEAR WARRANTY INSTRUCTION MANUAL INSTRUCTION MANUAL FILE: 091-106-150-XX-120 DATE: 10-2-2009 REV: A INDUSTRIAL CHARGER AUTOMATIC BATTERY CHARGER SERIES 150 MODEL # 091-106-150-XX-120 3 YEAR WARRANTY KUSSMAUL ELECTRONICS CO., INC. 170

More information

TWO STAGE GAS BURNER GULLIVER RSD SERIES RS5D 160/ kw

TWO STAGE GAS BURNER GULLIVER RSD SERIES RS5D 160/ kw TWO STAGE GAS BURNER GULLIVER RSD SERIES 160/208 345 kw The Riello Gulliver is a new model of the series of two stage gas burners, characterized for its small dimensions in spite of its high combustion

More information

ONE STAGE GAS BURNER GULLIVER RSF SERIES RS5F kw

ONE STAGE GAS BURNER GULLIVER RSF SERIES RS5F kw ONE STAGE GAS BURNER GULLIVER RSF SERIES 160 330 kw The Riello Gulliver, is a new model of the series of one stage gas burners, developed to respond to any request for light industrial processes like bakery

More information

K25000 & KD25000 Series

K25000 & KD25000 Series K25000 & KD25000 Series Fire Alarm Power Supplies Installation, Commissioning and Operating Manual Man-1128 Issue 14 January 2016 Man-1128_K25400_series_Power_Supply_Manual_14 Page 1 of 20 Section Page

More information

A419ABG-3C Electronic Temperature Control

A419ABG-3C Electronic Temperature Control Installation Instructions Issue Date June 16, 2003 A419ABG-3C Electronic Temperature Control Application IMPORTANT: Use this A419ABG-3C Electronic Temperature Control only as an operating control. Where

More information

TCS 1200 Portable Temperature Calibrator

TCS 1200 Portable Temperature Calibrator TCS 1200 Portable Temperature Calibrator Instruction Manual MM 2 CONTENTS DESCRIPTION EMC Information Electrical Safety Environmental Ratings Insert Warning Health & Safety Instructions Guarantee Cautionary

More information

Emergency lighting units EM converterled. EM converterled BASIC 90 V BASIC series

Emergency lighting units EM converterled. EM converterled BASIC 90 V BASIC series BASIC 90 V BASIC series Product description lighting Driver for manual testing For self-contained emergency lighting For modules with a forward voltage of 40 97 V SEV for output voltage < 120 V DC ow profile

More information

Emergency lighting units EM converterled. EM converterled ST 90 V SELFTEST series

Emergency lighting units EM converterled. EM converterled ST 90 V SELFTEST series ST 90 V SEFTEST series Product description lighting Driver with self-test function For self-contained emergency lighting For modules with a forward voltage of 40 97 V SEV for output voltage < 120 V DC

More information

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model ACO. R EN - Edition 06-01/12/2010

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model ACO. R EN - Edition 06-01/12/2010 SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model ACO R8215222-06EN - Edition 06-01/12/2010 Domestic Gas Boilers ACO 537060 ACO 27 MFFI MET...... 537061 ACO 27 MFFI GPL...... 537062 ACO 27 RFFI SYSTEM MET......

More information

DuraDrive MF /MS Series Non-spring Return Rotary Electronic Damper Actuators 24 Vac Three-position/Modulating

DuraDrive MF /MS Series Non-spring Return Rotary Electronic Damper Actuators 24 Vac Three-position/Modulating General Instructions DuraDrive MF4-653/MS4-653 Series Non-spring Return Rotary Electronic Damper Actuators 4 Vac Three-position/Modulating Description The DuraDrive direct-coupled, 4 Vac, non-spring return

More information

Series P215PR Direct Mount Pressure Actuated Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter)

Series P215PR Direct Mount Pressure Actuated Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter) PSC 0435 European Refrigeration Controls Catalogue Catalog Section 4 Product Bulletin Series Direct Mount Pressure Actuated Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression

More information

- Wiring Brochure Universal Reset Module 422e

- Wiring Brochure Universal Reset Module 422e - Wiring Brochure Universal Reset Module 422e W 422e 01/08 1 Information Brochure hoose controls to match application 2 Application Brochure Design your mechanical applications 3 Rough In Wiring Rough-in

More information

Emergency lighting units EM converterled. EM converterled ST 50 V SELFTEST series

Emergency lighting units EM converterled. EM converterled ST 50 V SELFTEST series ST 50 V SEFTEST series Product description lighting Driver with self-test function For self-contained emergency lighting For modules with a forward voltage of 10 52 V SEV for output voltage < 60 V DC ow

More information

1662/1663/1664 FC. Electrical Installation Tester. Safety Information. Warnings

1662/1663/1664 FC. Electrical Installation Tester. Safety Information. Warnings 1662/1663/1664 FC Electrical Installation Tester Safety Information Go to www.fluke.com to register your Product and find more information. A Warning identifies conditions and procedures that are dangerous

More information

Emergency lighting units EM converterled. EM converterled BASIC 50 V BASIC series

Emergency lighting units EM converterled. EM converterled BASIC 50 V BASIC series BASIC 50 V BASIC series Product description lighting Driver for manual testing For self-contained emergency lighting For modules with a forward voltage of 10 52 V SEV for output voltage < 60 V DC ow profile

More information

80 Series V Digital Multimeter Safety Information

80 Series V Digital Multimeter Safety Information 80 Series V Digital Multimeter Safety Information Limited Lifetime Warranty. See the Users Manual for the full warranty. Go to www.fluke.com to register your product and find more information. A Warning

More information

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h) Mechatronic Analog Timer H3AM Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Refer to Warranty and

More information

SAX Electronic Valve Actuator

SAX Electronic Valve Actuator SAX Electronic Valve Actuator Non-spring Return, 24 Vac, Proportional Control Technical Instructions Document No. 155-506 Description The SAX Non-spring Return (NSR), Electronic Valve Actuator requires

More information

1587 FC/1587/1577. Insulation Multimeter. Safety Information. Warnings

1587 FC/1587/1577. Insulation Multimeter. Safety Information. Warnings 1587 FC/1587/1577 Insulation Multimeter Safety Information Go to www.fluke.com to register your Product and find more information. A Warning identifies conditions and procedures that are dangerous to the

More information

WARNING MANUFACTURER ASSUMES NO LIABILITY IF UNIT OPERATED IN AN UNSAFE MANNER.

WARNING MANUFACTURER ASSUMES NO LIABILITY IF UNIT OPERATED IN AN UNSAFE MANNER. WARNING MANUFACTURER ASSUMES NO LIABILITY IF UNIT OPERATED IN AN UNSAFE MANNER. WARNING THIS INSTRUMENT GENERATES AND DELIVERS A HAZARDOUSLY HIGH VOLTAGE (5kV). BE EXTREMELY CAREFUL WHEN USING THIS INSTRUMENT.

More information

Electronic Ignition Module

Electronic Ignition Module 7 607 Electronic Ignition Module TQO31A27 Electronic ignition module for use with oil or gas burners operating with singleor double-pole ignition. The TQO31A27 and this Data Sheet are intended for use

More information

- Wiring Brochure Mixing Expansion Module 440

- Wiring Brochure Mixing Expansion Module 440 - Wiring Brochure Mixing Expansion Module 440 W 440 12/08 1 Information Brochure Choose controls to match application Application Brochure Design your mechanical applications 2 3 Rough-in Wiring Rough-in

More information

MT4000 Series SERVO MOTORS FOR AIR DAMPERS AND BUTTERFLY VALVES

MT4000 Series SERVO MOTORS FOR AIR DAMPERS AND BUTTERFLY VALVES UNIERSL GS LES T4000 Series SERO OTORS FOR IR DPERS ND BUTTERFLY LES PPLITI PRODUT HNDBOOK The T4000, T4001, T4002 and T4003 are servo motors to control and govern air lock of gaseous and liqued fuels.

More information

Lexium integrated drives

Lexium integrated drives Description ILp for CANopen, PROFIBUS DP, RS ILE with brushless DC motor Description ILE comprise control electronics with a fieldbus interface for CANopen DS, PROFIBUS DP or RS and a brushless DC motor.

More information

EUROTHERM ONTROLS. Two phase thyristor power switches. Product data

EUROTHERM ONTROLS. Two phase thyristor power switches. Product data TC2000 TC2001 EUROTHERM ONTROLS Two phase thyristor power switches Product data TC2000 TC2001 Thyristor power switches Compact, two phase thyristor power switches for electrical heating applications from

More information

BGD258 Series BASOTROL CE Approved Class A Gas Valve

BGD258 Series BASOTROL CE Approved Class A Gas Valve Product Bulletin Issue Date May 21, 2010 BGD258 Series BASOTROL CE Approved Class A Gas Valve The BGD258 Series multi-function gas control valve works in conjunction with an electronic sequence control

More information

Emergency lighting units EM converterled

Emergency lighting units EM converterled EM converter EM converter BASIC icd 50 V BASIC series Product description lighting Driver for manual testing For self-contained emergency lighting For modules with a forward voltage of 10 54 V SEV for

More information

CAUTION CM-SE CM-S21 CM-S41

CAUTION CM-SE CM-S21 CM-S41 CAUTION Safety, Technology & Innovation CM Series Operating Instructions for, CM-S21,, CM-S11, CMS31 CM Series Safety System This information is designed to help suitably qualified personnel install and

More information

KVC7934, KVC7936. Modulating Actuators without and with Power Failure Reposition For KVC Series Cartridge Valve. Specifications 12.

KVC7934, KVC7936. Modulating Actuators without and with Power Failure Reposition For KVC Series Cartridge Valve. Specifications 12. Modulating Actuators without and with Power Failure Reposition For KVC Series Cartridge Valve Specifications The specifications following are nominal and conform to generally accepted industry standards.

More information

i3000s/i2000 Flex AC Current Probe

i3000s/i2000 Flex AC Current Probe i3000s/ AC Current Probe Instruction Sheet Introduction The i3000s 24 Flex, i3000s 36 Flex, and AC Current Probes (the Probe) are used with oscilloscopes, digital multimeters, recorders or data loggers.

More information

OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc

OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc Document No. 155-187P25 EA GDE/GLB-1 OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc Description The OpenAir direct coupled 24 Vac non-spring

More information

OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc

OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc Technical Instructions Document No. 155-187P25 EA GDE/GLB-1 OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc Description The OpenAir direct

More information

Manual. BlueSolar Grid Inverter 1500 / / / / / 230

Manual. BlueSolar Grid Inverter 1500 / / / / / 230 Manual EN BlueSolar Grid Inverter 1500 / 230 2000 / 230 2800 / 230 4000 / 230 5000 / 230 Before you start This manual contains important information regarding installation and safe operation of this unit.

More information

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin LowNOx Commercial Gas Electronic Spark Ignition Sequence

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin LowNOx Commercial Gas Electronic Spark Ignition Sequence The Universal TM gas LowNOx series water heaters contain an electronic spark ignition system. The heater is connected to a 120VAC power source required by the transformer. The transformer steps down the

More information

RS/M SERIES. Modulating Gas Burners FIRING RATES

RS/M SERIES. Modulating Gas Burners FIRING RATES The RS/M burners series covers a firing range from 45 to 2650 kw, and it has been designed for use in low or medium temperature hot water boilers, hot air or steam boilers, diathermic oil boilers. Operation

More information

EPS/ELA-Series User Manual EPS/ELA 250W

EPS/ELA-Series User Manual EPS/ELA 250W EPS/ELA-Series User Manual EPS/ELA 250W EPS Stromversorgung GmbH Tel: +49 (0)821 570451 0 Index 3 Page: 1 Table of contents: Page 1. Features of ELA-Series... 3 1.1 Basic Functions... 3 1.2 Options...

More information

Lexium integrated drives

Lexium integrated drives Description ILp for DeviceNet, EtherCAT, Modbus TCP, ILE with brushless DC motor Description ILE comprise control electronics with a fieldbus interface for DeviceNet, EtherCAT, Modbus TCP or and a brushless

More information

LOW NOx TWO STAGE GAS BURNERS GULLIVER BSD SERIES BS1D 16/19 52 kw BS2D 35/40 91 kw BS3D 65/ kw BS4D 110/ kw

LOW NOx TWO STAGE GAS BURNERS GULLIVER BSD SERIES BS1D 16/19 52 kw BS2D 35/40 91 kw BS3D 65/ kw BS4D 110/ kw LOW NOx TWO STAGE GAS BURNERS GULLIVER BSD SERIES 1/19 5 kw 35/4 91 kw 5/75 19 kw 11/14 4 kw The Riello Gulliver BSD series of two stage gas burners, is a complete range of Low NOx emission products, developed

More information

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL Matrix APAX 380V-415V 50Hz TECHNICAL REFERENCE MANUAL WARNING High Voltage! Only a qualified electrician can carry out the electrical installation of this filter. Quick Reference ❶ Performance Data Pages

More information

Power consumption Wire/transformer sizing. Motor. Spring return. Motor. Spring return. EMC Low voltage directive

Power consumption Wire/transformer sizing. Motor. Spring return. Motor. Spring return. EMC Low voltage directive Technical data sheet NFU Damper actuator for operating air control dampers in ventilation and air-conditioning systems for building services installations Torque: 10Nm Nominal voltage: AC 4... 40V DC 4...15V

More information

A419 Series Electronic Temperature Controls with NEMA 1 or NEMA 4X Watertight Enclosures

A419 Series Electronic Temperature Controls with NEMA 1 or NEMA 4X Watertight Enclosures Installation Instructions Issue Date April 8, 2008 A419 Series Electronic Temperature Controls with NEMA 1 or NEMA 4X Watertight Enclosures Application IMPORTANT: The A419 Series Electronic Temperature

More information

GULLIVER BS SERIES. Low NOx One Stage Gas Burners FIRING RATES. BS kw BS kw BS kw BS kw.

GULLIVER BS SERIES. Low NOx One Stage Gas Burners FIRING RATES. BS kw BS kw BS kw BS kw. The Riello Gulliver BS series of one stage gas burners, is a complete range of Low NOx emission products, developed to respond to any request for home heating, conforming to the most severe standards regarding

More information

Switching DC Power Supply

Switching DC Power Supply 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Model 1693, 1694 Switching DC Power Supply INSTRUCTION MANUAL 1 Safety Summary

More information

INSTALLATION/OPERATING INSTRUCTIONS TSC

INSTALLATION/OPERATING INSTRUCTIONS TSC INSTALLATION/OPERATING INSTRUCTIONS TSC Two-Stage Set Point Control with External Activation Two-Stage Heating (Rotation Included) Two-Stage Cooling (Rotation Included) Change-Over Control (Heat/Cool)

More information

Emergency lighting units EM converterled. EM converterled PRO 200 V PRO series

Emergency lighting units EM converterled. EM converterled PRO 200 V PRO series EM converter EM converter PRO 200 V PRO series Product description lighting Driver with DAI interface and automatic test function For self-contained emergency lighting For modules with a forward voltage

More information

INSTALLATION OPERATION AND MAINTENANCE MANUAL SMITSVONK HIGH ENERGY IGNITION UNIT TYPE: E-LIGHT

INSTALLATION OPERATION AND MAINTENANCE MANUAL SMITSVONK HIGH ENERGY IGNITION UNIT TYPE: E-LIGHT INSTALLATION OPERATION AND MAINTENANCE MANUAL SMITSVONK HIGH ENERGY IGNITION UNIT TYPE: E-LIGHT-161609 Read before commencement of all work! This ignition unit must be mounted in accordance with the applicable

More information