Manual presetting valve MSV-C
|
|
- Mae Harvey
- 5 years ago
- Views:
Transcription
1 Description / Application MSV-C is used for balancing the flow in cooling, heating and domestic water systems. MSV-C is a combined manual presetting valve with following features: Fixed measurement orifice. Supplied with 2 pcs. of measuring nipples for needles. Handwheel with shut-off function and clear 360 o reading Digital scale with lock function Measuring accuracy of fixed orifice ± 5% MSV-C is supplied with internal thread. MSV-C is made in standard brass and CR brass (CR - Corrosion Resistant). MSV-C Fan Coil MSV-C Fan coil terminals for cooling and heating. MSV-C or MSV-F2 MSV-C or MSV-F2 MSV-C or MSV-F2 Secondary circuit for cooling or heating in distribution systems. HEC VDB1C602 Danfoss 09/2008 1
2 Ordering MSV-C valve with measuring nipples Type Material Size kvs Connection Code no. CR brass, with measuring nipples (2 pcs.) Brass, with measuring nipples (2 pcs.) DN Rp ½" 003Z3001 DN Rp ¾" 003Z3002 DN Rp 1" 003Z3003 DN Rp 1¼" 003Z3004 DN Rp 1½" 003Z3005 DN Rp 2" 003Z3006 DN Rp ½" 003Z3020 DN Rp ¾" 003Z3021 DN Rp 1" 003Z3022 DN Rp 1¼" 003Z3023 DN Rp 1½" 003Z3024 DN Rp 2" 003Z3025 MSV-C valve without measuring nipples Type Material Size kvs Connection Code no. Brass, without nipples (with plug) CR brass, without measuring station DN Rp ½" 003Z3010 DN Rp ¾" 003Z3012 DN Rp 1" 003Z3013 DN Rp 1¼" 003Z3014 DN Rp 1½" 003Z3015 DN Rp 2" 003Z3016 DN Rp ½" 003Z3030 DN Rp ¾" 003Z3031 DN Rp 1" 003Z3032 DN Rp 1¼" 003Z3033 DN Rp 1½" 003Z3034 DN Rp 2" 003Z3035 Note for commissioning: kvs for measuring orifice is explained on page 4 and 5. MSV-C valve with draincock and measuring nipples Type Material Size kvs Connection Code no. CR brass, draincock, with measuring nipples (2 pcs.) Brass, draincock, with measuring nipples (2 pcs.) DN Rp ½" 003Z3800 DN Rp ¾" 003Z3801 DN Rp 1" 003Z3802 DN Rp 1¼" 003Z3803 DN Rp 1½" 003Z3804 DN Rp 2" 003Z3805 DN Rp ½" 003Z3811 DN Rp ¾" 003Z3812 DN Rp 1" 003Z3813 DN Rp 1¼" 003Z3814 DN Rp 1½" 003Z3815 DN Rp 2" 003Z VDB1C602 Danfoss 09/2008 HEC
3 Accessories Type Size Code no. Measuring nipples for needles, 2 pcs. 36 mm ¼" 003Z0100 Extended nipples for needles, 2 pcs. 60 mm ¼" 003Z0106 Measuring needles, 2 pcs. 3.0 mm 003Z0107 Drain cook ¾" - ¼" 003L8141 Measuring connector for drain cook ¾" - Rectus 003L8143 Measuring equipment PFM L8230 Handwheel, for valve size DN Z3050 Handwheel, for valve size DN Z3051 Handwheel, for valve size DN Z3052 Handwheel, for valve size DN Z3053 Handwheel, for valve size DN Z3054 Handwheel, for valve size DN Z3055 Insulation caps Type DN 15 DN 20 DN 25 DN 32 DN 40 DN 50 Code no. 003Z Z Z Z Z Z3045 The insulation caps are made of polyurethane foam with a polystyrene shield, and they are designed for temperatures from -30 o C to +120 o C (λ = W/mK). Design 1. Valve body (CR brass) 2. Bonnet 3. Setting spindle 4. Valve cone 5. O-ring 6. O-ring 7. Pos. indicator 8. Retaining ring 9. Handle 10. Lock setting screw 11. Knob 12. Pin 13. Valve information cap 14. Fixed orifice 15. Label 16. Digital scale 17. Valve seal Locking and shut-off Informations on the label: Type: MSV-C S : max. S Dimension:..... DN 15 MSV-C valve can shut-off the flow by turning the handwheel clockwise to the stop. The presetting can be locked with an 6 mm Allen key. HEC VDB1C602 Danfoss 09/2008 3
4 Measuring Fixed orifice (S ) and differential pressure will be used in the measuring equipment to define the flow. Measuring on a fixed orifice valve i.e. MSV-C is very fast and easy. The amount of information entered into the measuring equipment is low. The Danfoss measuring equipment PFM 3000: Type: Danfoss MSV-C Dimension: DN 20 Now presetting scale can be turned to the desired position and at the same time the exact flow can be read at the measuring equipment. The flow running through the MSV-C valve can be measured by using the Danfoss measuring equipment PFM 3000 or other brands of measuring equipment. The MSV-C valve is supplied with two measuring nipples for 3 mm needles. The other brands of measuring equipment. S : 4.1 (orifice DN 20 MSV-C) Now presetting scale can be turned to the desired flow and at the same time the exact flow can be read at the measuring equipment. The measuring nipples are placed across a fixed orifice and the differential pressure can be measured across this orifice. Fixed orifice The fixed orifice is a very presise way to define the flow running through a presetting valve. Our fixed orifice is created in the valve body and has a fixed and stable k vs. Sizing depends on valve dimension. On a fixed orifice valve i.e. MSV-C the orifice is fixed and stable because it is created in the valve body. Measuring accuracy ± 5%. Setting / adjustment The flow can be adjusted with the presetting hand-wheel. The digital presetting scale indicates the value of setting. Turn the presetting hand-wheel clockwise. The K v value will be smaller and finally shut-off the flow. Turn the presetting hand-wheel counter-clockwise and K v will increase. The digital presetting scale indicates: 0.0 Closed setting orifice. 8.0 Completly opened setting orifice. At page 6-17, the valve diagram shows the digital presetting scale setting no. and K v. 4 VDB1C602 Danfoss 09/2008 HEC
5 Valve selection table Size *Minimum flow rate (l/s) Max balancing pressure (kpa) S orifice DN Q DN Q DN Q DN Q DN Q DN Q * Minimum flow rate at 1kPa pressure drop across orifices. S K VS valve K VS orifice k vs orifice k vs valve k vs - k vs across orifices - k vs across the cone - k vs include orifice and cone. K VS Example: Wanted: Correct valve size and presetting. Given: Max. pipe flow Q= 0.80 m 3 /h p r = 15 kpa p a = 40 kpa p m = 10 kpa Solution: MSV-C size and presetting: The differential pressure across MSV-C can be calculated: p i = p a - p v - p m p i = 45 kpa - 15 kpa - 10KPa = 20 kpa The correct valve size on presetting can be found in the graph (page 7). Q= 0.80 m 3 /h and p i = 20 kpa Intersect the setting lines at point 'A' - presetting 3.2 on valve size DN 20. p i Pressure drop across MSV-C valve p m Pressure drop across valve p r Necessary pressure for the riser p a Available pressure for the riser Setting can be also calculated from the formula: k v = Q[m 3 /h] 0.8 = p i [bar] 0.20 = 1.7 m 3 /h what corespondent presetting 3.2. Technical data Max. static working pressure Static test pressure Max. differential pressure across valve 16 bar 25 bar Max. flow temperature 120 C Min. temperature Cooling liquids 1.5 bar (150 kpa) -10 C Glycol and HYCOOL Material of parts in contact with water Valve body, spindle, cone, etc. O-rings Corrosion Resistant (CR) or standard brass HMBR HEC VDB1C602 Danfoss 09/2008 5
6 DN 15 with measuring station DN 15 with measuring station Flow characteristics DN 15 with meas. station 6 VDB1C602 Danfoss 09/2008 HEC
7 DN 15 without measuring station DN 15 without measuring station Flow characteristics DN 15 without meas. station HEC VDB1C602 Danfoss 09/2008 7
8 DN 20 with measuring station DN 20 with measuring station Flow characteristics DN 20 with meas. station 8 VDB1C602 Danfoss 09/2008 HEC
9 DN 20 without measuring station DN 20 without measuring station Flow characteristics DN 20 without meas. station HEC VDB1C602 Danfoss 09/2008 9
10 DN 25 with measuring station DN 25 with measuring station Flow characteristics DN 25 with meas. station 10 VDB1C602 Danfoss 09/2008 HEC
11 DN 25 without measuring station DN 25 without measuring station Flow characteristics DN 25 without meas. station HEC VDB1C602 Danfoss 09/
12 DN 32 with measuring station DN 32 with measuring station Flow characteristics DN 32 with meas. station 12 VDB1C602 Danfoss 09/2008 HEC
13 DN 32 without measuring station DN 32 without measuring station Flow characteristics DN 32 without meas. station HEC VDB1C602 Danfoss 09/
14 DN 40 with measuring station DN 40 with measuring station Flow characteristics DN 40 with meas. station 14 VDB1C602 Danfoss 09/2008 HEC
15 DN 40 without measuring station DN 40 without measuring station Flow characteristics DN 40 without meas. station HEC VDB1C602 Danfoss 09/
16 DN 50 with measuring station DN 50 with measuring station Flow characteristics DN 50 with meas. station 16 VDB1C602 Danfoss 09/2008 HEC
17 DN 50 without measuring station DN 50 without measuring station Flow characteristics DN 50 without meas. station HEC VDB1C602 Danfoss 09/
18 Dimensions without nipples (with plug) with 2 pcs. measuring nipples F F E E SW C D F E B B B SW A C D A Size (DN) Thread SW A B C D E F without nipples Weight (kg) with nipples 15 R p ½ R p ¾ R p R p 1¼ R p 1½ R p C D A SW Size (DN) Thread SW A B C D E F Weight (kg) 15 R p ½ R p ¾ R p R p 1¼ R p 1½ R p VDB1C602 Danfoss 09/2008 HEC
19 HEC VDB1C602 Danfoss 09/
20 Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved. Danfoss A/S Comfort Division Hårupvænget 11 Hårup DK-8600 Silkeborg Denmark Tel.: Fax: Danfoss Trata d.o.o. Jožeta Jame 16, P.O.B Ljubljana - Šentvid Slovenia Tel.: / Fax: / VDB1C602 Danfoss 09/2008 HEC
Manual presetting valves LENO MSV-BD
Manual presetting valves LENO MSV-BD Description LENO MSV-BD is a range of manual valves for balancing flow in heating, cooling and domestic hot water systems. LENO MSV-BD is a combined presetting and
More informationManual Presetting Valves LENO MSV-B
Data Sheet Description LENO MSV-B is a new generation of manual valves for balancing flow in heating, cooling and domestic hot water systems. LENO MSV-B is a combined presetting and shut off valve with
More informationAutomatic balancing valves ASV-PV DN (3rd gen.)
Automatic balancing valves ASV-PV DN 50-100 (3rd gen.) Description / Application Partner valve ASV-PV DN 50 ASV-PV DN 65-100 MSV-F2 DN 50-100 ASV balancing valves are used for dynamic hydronic balance
More informationValve bodies type RA-N with integrated presetting
Data Sheet Application Straight version Angle version Left mounted angle version Horizontal angle version All RA-N valve bodies can be used together with all types of thermostatic elements in the RA 2000
More informationHigh Capacity Valve Body, Type RA-G
Data Sheet The RA-G valves are fitted with a grey protective cap. This protective cap must not be used as a manual shut off device. A special manual shut off device is available (code no. 013G3300). Application
More informationPre-Fabricated Flushing Bypass Assembly for Plant Applications Hero Plant DN15-150
Pre-Fabricated Flushing Bypass Assembly for Plant Applications Description Hero Plant is a pre-fabricated, flushing bypass arrangement for balance, control, isolation, and operation of plant devices. Flow
More informationIntegrated Presetting Valves for Normal (013G0380) and Small (013G0381) Volume Flows
Integrated Presetting Valves for Normal (013G0380) and Small (013G0381) Volume Flows Application Integrated valves, type RA-N (013G0380) and RA- U (013G0381), with built-in presetting are designed for
More informationFlow controller with integrated control valve (PN 16) AHQM - return and flow mounting
Flow controller with integrated control valve (PN 16) AHQM - return and flow mounting Description Controllers are used together with Danfoss electrical actuators: DN 15-32 with - AMV(E) 10 - AMV(E) 13
More informationSTAF-SG. ANSI flanges. Balancing valves DN
STAF-SG ANSI flanges Balancing valves DN 20-400 IMI TA / Balancing valves / STAF-SG ANSI flanges STAF-SG ANSI flanges A flanged, ductile iron balancing valve that delivers accurate hydronic performance
More informationFlow controller (PN 25) AVQ - return and flow mounting
Data sheet Flow controller (PN 5) - return and flow mounting Description is a self-acting flow controller primarily for use in district heating systems. The controller closes when set max. flow is exceeded.
More informationIntegrated Valve with Presetting for Manifolds in Two-Pipe Heating Systems
Data Sheet Integrated Valve with Presetting for Manifolds in Two-Pipe Heating Systems The integrated valve is designed for manifold applications in combination with a system connection piece. Valve and
More informationPressure reduction controllers (PN 25) AVDS - for steam AVD - for water
Data sheet Pressure reduction controllers (PN 25) - for steam AVD - for water Description Main data AVD: DN 15-50 k VS 0,4-25 m 3 /h PN 25 Setting range: 1-5 bar / 3-12 bar Temperature: - Circulation water/glycolic
More informationAssisted lift operated 2/2-way solenoid valves Type EV251B
Data sheet Assisted lift operated 2/2-way solenoid valves Type EV251B EV251B with assisted lift is especially suitable for applications such as closed systems with low and fluctuating pressure conditions
More informationStatic Balancing Valve
Static Balancing Valve Series W-JP45X-16Q Sizes: DN50-DN300 APPLICATION The Series W-JP45X Static Balancing Valve is designed for flow balancing in cooling, heating or process water systems. Its measuring
More informationIntegrated Presetting Valves - for Normal Volume Flows RA-N and for Small Volume Flows RA-U
Integrated Presetting Valves - for Normal Volume Flows RA-N and for Small Volume Flows Application RA-N 013G7382 013G7387 Integrated valves, type RA-N 013G7382 and 013G7387, with built-in presetting are
More informationSTAF, STAF-SG. Balancing valves PN 16 and PN 25 DN
STAF, STAF-SG Balancing valves PN 16 and PN 25 DN 20-400 IMI TA / Balancing valves / STAF, STAF-SG STAF, STAF-SG A flanged, cast iron (STAF) and ductile iron (STAF-SG) balancing valve that delivers accurate
More informationFloor heating system, heating circuit with FHV-A in flow.
Application FHV control valves are ideally suited for controlling the temperature of individual under-floor heated rooms and for systems using floor-heating in conjunction with radiators. Danfoss offers
More informationHERZ 7217 V. Integral Fixed Orifice Control Valve HERZ 7217 V. Data sheet 7217 V, Issue Size in mm. STRÖMAX Fig No DN L Lm Rp H SW kv kvs
HERZ 7217 V Integral Fixed Orifice Control Valve Data sheet 7217 V, Issue 1011 Size in mm STRÖMAX Fig No DN L Lm Rp H SW kv kvs TS-V LF 1 7217 50 15 83 28,5 1/2 41 27 0,07-0,45 0,48 TS-V MF 1 7217 59 15
More informationSTAF, STAF-SG. Balancing valves PN 16 and PN 25 DN
STAF, STAF-SG Balancing valves PN 16 and PN 25 20-400 IMI TA / Balancing valves / STAF, STAF-SG STAF, STAF-SG A flanged, cast iron (STAF) and ductile iron (STAF-SG) balancing valve that delivers accurate
More informationPressure relief controller AVA (PN 25)
Data sheet Pressure relief controller AVA (PN 25) Description AVA is a self-acting pressure relief controller primarily for use in district heating systems. The controller is normally closed and opens
More informationTechnote. Frese OPTIMA Compact DN10-DN50 - pressure independent balancing & control valve. Application. Features. Benefits.
Page of 5 Frese OPTIMA Compact DN-DN5 Application Frese OPTIMA Compact pressure independent balancing & control valve (PIBCV) is used in heating and cooling systems in applications with Fan Coil Units,
More informationTechnote. Frese OPTIMA - Pressure independent control & balancing valve. Application. Features. Benefits.
Page 1 of 12 Application pressure independent control valve (PICV) is used in heating and cooling systems in applications with Fan Coil Units, Air Handling Units or other terminal unit applications. provides
More informationProduct Sheet Pre-Fabricated Flushing Bypass Assembly for Terminal Applications Mini-Flush 40
Product Sheet Pre-Fabricated Flushing Bypass Assembly for Terminal Applications Mini-Flush 40 Description Miniflush40 is a pre-fabricated, flushing bypass arrangement for balance, control, isolation, and
More informationPressure independent balancing and control valve AB-QM DN
Pressure independent balancing and control valve AB-QM DN 10-150 AB-QM valve equipped with an actuator is a control valve with full authority and automatic balancing function - flow limiter. Typical applications
More informationHigh capacity valve body, type RA-G
Application The RA-G valves are fitted with a grey protective cap. This protective cap must not be used as a manual shut off device. A special manual shut off device is available (code no. 013G3300). The
More informationSTAF-SG. ANSI flanges. Balancing valves Size 3/4-16
STAF-SG ANSI flanges Balancing valves Size 3/4-16 IMI TA / Balancing valves / STAF-SG ANSI flanges STAF-SG ANSI flanges A flanged, ductile iron balancing valve that delivers accurate hydronic performance
More informationPressure relief controller AFA / VFG 2(1) (PN 16, 25, 40)
Data sheet Pressure relief controller AFA / VFG 2(1) (PN 16, 25, 40) Description The controller is a self-acting pressure relief controller primarily for use in district heating systems. The controller
More informationX-tra Collection for designer radiators and bathroom towel rails
and bathroom towel rails Application The new X-tra Collection is a TRV specially designed for towel rails and designer radiators. Its new and innovative self-sealing ½" valve to radiator connection makes
More informationPressure independent control valve with integrated flow limiter AVQM (PN 16) - return and flow mounting
Data sheet Pressure independent control valve with integrated flow limiter AVQM (PN 16) - return and flow mounting Description Controllers are used together with Danfoss electrical actuators: AMV 0 1)
More informationChangeOver6 and NovoCon ChangeOver6 - Motorized 6-port Ball Valves
- Motorized 6-port Ball Valves Description NovoCon The and NovoCon are 6-port motorized ball valves that performs a diverting function between two water circuits in 4-pipe changeover system. This diverting
More informationRA-N Valve Bodies with Pressfit Connection and Self-Sealing Tailpiece for Two Pipe Systems
Data Sheet RA-N Valve Bodies with Pressfit Connection and Self-Sealing Tailpiece for Two Pipe Systems Application Straight Angle The valve bodies with pressfit connection are used for heating systems with
More informationPressure independent balancing and control valve
Pressure independent balancing and control valve AB-QM DN 10-150 AB-QM valve equipped with an actuator is a control valve with full authority and automatic balancing function - flow limiter. Typical applications
More informationFlow-compensated temperature controller AVTQ DN 15
Data sheet Flow-compensated temperature controller AVTQ DN 15 Description AVTQ is a self-acting flow-compensated temperature controller primarily for use in district heating systems with plate heat exchangers
More informationCombined automatic balancing valve AB-PM valve DN 10-32, PN 16
Data sheet Combined automatic balancing valve AB-PM valve DN 10-32, PN 16 Description AB-PM is a combined automatic balancing valve. It features three function in compact valve body: 1. Differential pressure
More informationValves, controllers + systems Double regulating and commissioning valves Hydrocontrol F cast iron, PN 16
Valves, controllers + systems Double regulating and commissioning valves Hydrocontrol F cast iron, PN The Oventrop Quality Management System is certified to DIN-EN-ISO 9001 Technical information Application:
More informationV5032. Kombi-2-plus Manual double regulating balancing valve. Product specification sheet
V503 Kombi--plus Manual double regulating balancing valve Product specification sheet Application The V503 Kombi--plus is a static, variable orifice doubleregulating balancing valve for the return with
More informationDescription. Ballorex Venturi. Versions. Benefits. Robinets manuels Balancing
Ballorex Venturi Description The Ballorex Venturi is a range of manual balancing valves used in water-based heating and cooling systems to ensure an evenly distributed flow in zones, branches, risers and
More informationProduct Sheet Pre-Fabricated Flushing Bypass Assembly for Plant Applications Hero Plant DN15-150
Product Sheet Pre-Fabricated Flushing Bypass Assembly for Plant Applications Hero Plant DN15-150 Description Hero Plant is a pre-fabricated, flushing bypass arrangement for balance, control, isolation,
More informationSSM Floor Heating Manifold
Application The manifold consists of a supply and return manifold. The supply manifold includes possibility for individual shut-off of each circuit on flowmeter or shut-off valve. The return manifold is
More informationBallorex Vario. Description. Versions. Benefits. Applications. Balancing
Ballorex Vario Description Ballorex Vario is a variable orifice double regulating valve for balancing water-based heating and cooling systems. The balancing performed ensures the required distribution
More information950x. Description. Part List
Via Circonvallazione, 308 Valduggia (VC), Italy Tel: +39 063 4789 Fax: +39 063 47895 950x Variable Orifice Bronze Double Regulating Valve valvoindustria ing.rizzio s.p.a. Description Variable orifice bronze
More informationPressure Independent Control Valve AB QM, ½ thru 2 2½ thru 4 5 thru 10 Valve Size
Features and Benefits Danfoss 2016.04 The AB QM temperature control valve provides pressure independent regulation of flow while also providing flow limiting system balance. The valve internally contains
More informationTechnote. Frese OPTIMIZER - pressure independent 4-pipe coil control unit. Application. Benefits. Features.
Page of 7 Application control unit, in conjunction with the associated hydraulic set provides a complete pressure independent balancing and control group for efficient and effective individual room or
More informationDynamic Valve Type RA-DV Pressure Independent Radiator Valve
Dynamic Valve Type RA-DV Pressure Independent Radiator Valve Application RA-DV straight version RA-DV angle version RA-DV angle Right & Left RA-DV UK (Axial) RA-DV is a series of pressure independent radiator
More informationFO-BV Series. Fixed-orifice balancing and control valves. Technical Data Sheet. WattsIndustries.com
FO-BV Series Fixed-orifice balancing and control valves Technical Data Sheet WattsIndustries.com Description FO-BV Series fixed-orifice threaded valves are designed for flow control and monitoring in climate
More informationTechnote. Frese ALPHA HCR Dynamic Balancing Valve. Application. Features. Benefits. Design. Installation. Operation.
Page 1 of 7 Application The (High Corrosion Resistant) Valves are particularly designed and manufactured for automatic balancing in Industrial applications. An integral part of the Valve is the ALPHA Cartridge,
More informationChanging pistons APP 21-43
MAKING MODERN LIVING POSSIBLE Instruction Changing pistons APP 21-43 ro-solutions.com Contents 1. Disassembling...3 2. Assembling...6 3. When should the pistons be replaced....8 4. Parts list for APP 21-38....9
More informationSonoSensor 30 Ultrasonic flow sensor
Data Sheet SonoSensor 30 Ultrasonic flow sensor Description MID examination certificate no.: LT-1621- MI004-030 SonoSensor 30 is an ultrasonic flow sensor especially designed for heating, cooling or combined
More informationTDU.3 floor distribution unit SK
SK General description and application The is intended for two pipe horizontal heating systems and includes connecting, measuring, regulating and distribution functions. The TDU.3 is easily installed on
More informationValves, controls + systems Cast iron double regulating/ commissioning valves PN 16 Hydrocontrol G
The Oventrop Quality Management System is certified to DIN-EN-ISO 9001 Application: Oventrop double regulating and commissioning valves Hydrocontrol G are installed in the pipework of hot water central
More informationOil pump type RSA. Catalogue 1. Burner Components
Burner Components Catalogue 1 Contents Application... page 2 Construction... page 3 Function... page 4 Technical data... page 6 Capacity and operating torque RSA 28... page 7 Capacity and operating torque
More informationBallorex Venturi 3.1 Introduction
3.1 Introduction Venturi Fixed Orifice Double Regulating Valve (FODRV) DN 15-600 1/2-24 Venturi description The Venturi is a range of manual balancing valves used in water-based heating and cooling systems
More informationDouble regulating and commissionig valves Hydrocontrol F cast iron, PN 16 Hydrocontrol FR bronze, PN 16 Hydrocontrol FS nodular cast iron, PN 25
Hydrocontrol FR bronze, PN 16 Hydrocontrol FS nodular cast iron, PN 25 The Oventrop Quality Management System is certified to DIN-EN-ISO 9001 Technical Information Application: Oventrop double regulating
More informationTemperature controller AVT with safety temperature monitor STM/VG(F) (PN25)
Data sheet Temperature controller AVT with safety temperature monitor STM/VG(F) (PN25) Description Controller closes on rising temperature. TR1240 The controllers are: Type-tested acc. to EN 14597 and
More informationPressure independent balancing and control valve AB-QM DN
Data sheet Pressure independent balancing and control valve AB-QM DN 10-250 The AB-QM valve equipped with an actuator is a control valve with full authority and an automatic balancing function / flow limitation.
More informationTechnote. CirCon/TemCon - thermostatic valves for domestic hot water. Application. Advantages. Functions.
Page 1 of 8 CirCon/TemCon Application CirCon and TemCon are control valves designed for domestic hot water installations with circulation. The valves automatically control the temperature of the water
More informationDifferential pressure controller with flow limitation and with integrated control valve (PN 16) AHPBM-F flow mounting, fixed setting
Data sheet Differential pressure controller with flow limitation and with integrated control valve (PN 16) AHPBM-F flow mounting, fixed setting Description The controller has a control valve with adjustable
More informationChanging pistons APP and APP 16-22
MAKING MODERN LIVING POSSIBLE Instruction Changing pistons APP 11-13 and APP 16-22 ro-solutions.com Contents 1. Disassembling...3 2. Assembling...5 3. When should the pistons be replaced?....7 This document
More informationActuator type ABNM with Theft Protection, 0-10 V Proportional
Actuator type ABNM with Theft Protection, 0-10 V Proportional Application The ABNM actuator is a thermoelectric actuator for opening and closing valves in the fields of heating, ventilation and air conditioning
More informationSTV DN 10-50, Balancing valve
STV DN -0, Balancing valve High accuracy Easy to adjust Quick to commission Dimension: DN -0 Temperature: -0 C till + C Pressure class: PN 0 June 0 rev. Description STV (M,F,G) DN -0 Application The manual
More informationPremounted Midi Shunts
Application Midi Shunt 088U0181 - with one circuit Midi Shunt 088U0182 - with two circuits Midi Shunt 088U0183 - with three circuits The Danfoss floor heating midi shunt is a series of pre-mounted shunts
More informationZONE CONTROLE / 2-WAY
ZONE CONTROLE / 2-WAY PRESSURE INDEPENDENT BALANCING AND CONTROL VALVE ON/OFF High-performing and compact, these pressure-independent temperature control valves for variable flow heating and cooling systems,
More informationServo-operated 2/2-way solenoid valves with isolating diaphragm Type EV222B
Data sheet Servo-operated 2/2-way solenoid valves with isolating diaphragm Type EV222B EV222B is an indirect servo-operated solenoid valve programme for use in connection with contaminated or aggressive
More informationPressure independent balancing and control valve For ON/OFF control
KT 512 Pressure independent balancing and control valve For ON/OFF control Pressurisation & Water Quality Balancing & Control Thermostatic Control ENGINEERING ADVANTAGE High-performing and compact, these
More informationAPP S pumps APP S / APP S / APP S 21-38
MAKING MODERN LIVING POSSIBLE Instruction APP S 2.0-3.5 / APP S 5.1-9.0 / APP S 21-38 ro-solutions.com Instruction Table of Contents 1. Identification...2 2. System design...3 2.1 Open system design...3
More informationV5000, V5010 Kombi-3-plus BALANCING AND SHUTOFF VALVES
V5000 Kombi-3-plus RED V5000, V5010 Kombi-3-plus BALANCING AND SHUTOFF VALVES CONTENTS PRODUCT DATA Overview... 2 Design... 2 Materials... 2 Application... 2 Features... 2 Specifications... 2 Ordering
More informationControl Card VLT FC Series
These instructions describe the replacement of the control card in: VLT HVAC Drive FC 102. VLT Refrigeration Drive FC 103. VLT AQUA Drive FC 202. VLT AutomationDrive FC 301/FC 302. VLT Lift Drive LD 302.
More informationHorizontal Distribution Units - HDU Multi-port
Application Danfoss pre-fabricated HDU distribution units are made for distribution and measuring of waterbased heating in 2-pipe horizontal systems. A HDU is easily mounted on the apartment wall and connected
More informationTechnote. Frese YDF-2F & YDF-20F - differential pressure control valve. Application. Benefits. Features.
Page 1 of 5 Application Frese YDF-2F and YDF-20F differential pressure control valves are used in central heating-, ventilation-, and district heating systems This model is a high-performing adjustable
More informationExtensions to a comprehensive product range
Extensions to a comprehensive product range As part of our range of motorized control valves you can also find ON/OFF butterfly valves and zone valves applicable for use within heating, ventilation and
More informationOne. The performance of your wind turbine relies on the quality of its small components. ia.danfoss.com. Brochure Mobile Hydraulic
Brochure Mobile Hydraulic The performance of your wind turbine relies on the quality of its small components One stop shop - reducing your supply base and boosting your bottom line ia.danfoss.com Efficient
More informationDisassembling and assembling isave 21
MAKING MODERN LIVING POSSIBLE Service instruction Disassembling and assembling isave 21 isave.danfoss.com Table of Contents 1. General introduction....2 2. Disassembling the isave....3 3. Disassembling
More informationON/OFF zone valves AMZ 112, AMZ 113
Data sheet ON/OFF zone valves AMZ 112, AMZ 113 Description The ON/OFF zone valves type AMZ 112 and AMZ 113 are typical used in connection with: Domestic and commercial central heating applications Domestic
More informationMikrotherm F. Manual Radiator Valves With presetting
Mikrotherm F Manual Radiator Valves With presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Mikrotherm F Mikrotherm F The Mikrotherm F manual radiator valve is used in warm water pump heating
More informationSonoMeter 30 Energy Meters
SonoMeter 30 Energy Meters Description MID examination certificate no.: LT-1621-MI004-020 The Danfoss SonoMeter 30 is a range of ultrasonic, compact energy meters intended for measuring energy consumption
More informationTwo- and three way valves VFG.. / VFGS 2 / VFU.. for self-acting thermostats and electrical actuators
for self-acting thermostats and electrical actuators Description VFG 2 VFG 21 (see pages 2, 3, 4) Valves for heating, district heating and cooling systems. The valves can be used with following actuators:
More informationOne specification for the entire platform. Five different function modules could share a common housing.
One platform Multiple options The SVL Line Components - members of the SVL Flexline family. Flexibility is the key word and based on a common housing (angle- or straightway). The inserts in the SVL platform
More informationHydrocontrol VFC cast iron, PN 16 Hydrocontrol VFR bronze, PN 16 Hydrocontrol VFN nodular cast iron, PN 25 Double regulating and commissioning valves
Hydrocontrol VFC cast iron, PN 16 Hydrocontrol VFR bronze, PN 16 Technical Information Application: Oventrop double regulating and commissioning valves Hydrocontrol VFC/VFR/VFN are installed in the pipework
More informationInstallation Instructions In-back/Out-back Cooling Kit for D5h/D6h and D7h/D8h Enclosures VLT Series FC 102, FC 202, and FC 302
In-back/Out-back Cooling Kit for D5h/D6h and D7h/D8h Enclosures VLT Series FC 102, FC 202, 1.1 Description Base plate assembly The back-channel cooling (in-back/out-back) kit is designed for the D5h/D6h
More informationFlow controller with integrated control valve (PN 16) AVQM - return and flow mounting
Data sheet Flow controller with integrated control valve (PN 16) AVQM - return and flow mounting Description The controller has a control valve with adjustable flow restrictor, connection neck for electrical
More informationFlow controller with integrated control valve (PN 16) AHQM return and flow mounting
Data sheet Flow controller with integrated control valve (PN 16) AHQM return and flow mounting Description DN 15-32 DN 40, 50 DN 50-100 DN 125 DN 150 DN 200, 250 AHQM is a self-acting flow controller with
More informationData sheet Pressure independent control valve with integrated flow limiter AVQM (PN 16) - return and flow mounting
Pressure independent control valve with integrated flow limiter AVQM (PN 16) - return and flow mounting Description Controllers are used together with Danfoss electrical actuators: - AMV 150 1) - AMV(E)
More informationInstallation Instructions Bus Bar Kit for 6-pulse, 4-drive System VLT Series FC 102, FC 202, and FC 302. Description. Kit Part Number.
Description The bus bar kit is designed for the specific VLT HVAC Drive FC 102, VLT AQUA Drive FC 202, and VLT AutomationDrive FC 302 D4h-size VLT Parallel Drive Modules mounted in a Rittal TS8 enclosure.
More informationFlow controller (PN 25) AVQ - return and flow mounting
Data sheet Flow controller (PN 5) - return and flow mounting Description is a self-acting flow controller primarily for use in district heating systems. The controller closes when set max. flow is exceeded.
More informationBalancing Valves. Venturi Commissioning Valve (FODRV) & (DRV) Cu x Cu Compression DN10-DN50. BOSS TM 901SC Venturi DRV DN
Venturi Commissioning Valve (FODRV) & (DRV) Cu x Cu Compression DN-DN Balancing Valves BOSS TM 900SC Venturi FODRV DN1- BOSS TM 901SC Venturi DRV DN1- Specification The commissioning station and DRV incorporates
More informationTechnote. Frese ALPHA - automatic balancing valve. Application. Benefits. Features.
Page 1 of 6 Application The Frese APHA Valves are particularly designed and manufactured for the automatic balancing of heating and cooling circuits. The Frese APHA Cartridges - the second generation cartridges
More informationAPP pump instruction APP 21-43
MAKING MODERN LIVING POSSIBLE Instruction APP pump instruction APP 21-43 ro-solutions.com Table of Contents 1. Identification...2 2. System design...3 2.1 Open-ended systems with direct water supply....3
More informationInstallation Instructions for the TBPA Circulation Pump GOLD/SILVER C/COMPACT
GB.TBPA5.1615 Installation Instructions for the TBPA Circulation Pump GOLD/SILVER C/COMPACT 1. General If the air handling system includes an air heater for hot water without anti-frosting protection,
More informationSerie Ekoflux S. Flanged balancing valve. Application fields. Regulation. Ekoflux.S_GB_22/04/2015 HEATING CONDITIONING
Serie Ekoflux S Flanged balancing valve Ekoflux.S_GB_/0/0 Application fields CONDITIONING HEATING www.brandoni.it Serie Ekoflux S The valves in the series EKOFLUX balance the flow in main circuits or single
More informationIntegrated valves Series 3
Series 3 Application For decades, Danfoss has been the world s leading manufacturer of radiator valves and radiator thermostats. Danfoss invented the radiator thermostat back in 1943 and later developed
More informationHERZ-Motorised flow controler
HERZ-Motorised flow controler Control and regulating valve Data sheet 4006 SMART, Issue 0516 Dimensions in mm 4006 M 4006 R M R Order number DN G L L1 B B1 H without Actuator H with Actuator H1 1 4006
More informationAB-QM Pressure Independent Control Valve
valve equipped with an actuator is a control valve with full authority and automatic balancing function- flow limiter. Typical applications are: Temperature control and permanent automatic balancing on
More informationSonoSensor 30 Ultrasonic flow meter for heating and cooling applications
Installation & User Guide SonoSensor 30 Ultrasonic flow meter for heating and cooling applications 03/2017 Danfoss VDIGK202 www.heating.danfoss.com 1 Note! To ensure latest version of declaration, please
More informationThe precise step to take
New perspectives with Danfoss Saginomiya Electronic Expansion Valves The precise step to take Type KV Electronic Expansion Valves Energy efficiency Precision flow control with high resolution Compact and
More informationReport. PIBCV Tests. Report 52724/1 Edition 2 February 2010
Report www.bsria.co.uk PIBCV Tests This report supersedes Report 52724/1 Report 52724/1 Edition 2 February 2010 Carried out for: Danfoss Trata d.o.o. Jožeta Jame 16 SI-1210 Ljubljana Šentvid ID DDVS190729587
More informationSafety cap. Measuring probe. Seal. Operating principle. Advantages of balanced circuits. Balanced circuits have the following principal benefits:
Balancing valve, fixed orifice 0 series CALEFFI 0/ NA ACCREDITED ISO 900 FM ISO 900 No. 000 Function Product range Caleffi 0 series low lead, manual balancing valves are used to measure and adjust the
More informationAPP pump instruction APP and APP 16-22
MAKING MODERN LIVING POSSIBLE Instruction APP pump instruction APP 11-13 and APP 16-22 www.ro-solutions.com Table of Contents 1. Identification...2 2. System design...3 2.1 Open-ended systems with direct
More information9500 VIR VALVOINDUSTRIA ING.RIZZIO SPA
9500 REV 0504 VIR VALVOINDUSTRIA ING.RIZZIO SPA Via Circonvallazione, 0 308 Valduggia (VC) ITALY ph.+39 063 4789 fax.+39 063 47895 Info tecniche: tcnsales@vironline.com www.vironline.com VIR, leader in
More information3 & 4-Way Rotary Valves
Applications: 3-way Valve 4-way Valve The ESBE 3 and 4-Way rotary valves type F are designed for mixing or diverting applications on heating and cooling systems. The valves are capable of controlling and
More informationCCO kit. Compact Change Over - 6-way switch valve with motor QUICK FACTS
kit Compact Change Over - 6-way switch valve with motor QUICK FACTS Enables heating & cooling in products with only one heat exchanger circuit Precise flow regulation For 4-pipe cooling/heating system
More information