AB-QM Pressure Independent Control Valve
|
|
- Ashley Owens
- 5 years ago
- Views:
Transcription
1 valve equipped with an actuator is a control valve with full authority and automatic balancing function- flow limiter. Typical applications are: Temperature control and permanent automatic balancing on terminal units (chillers airhandling units, fan coils, induction units, chilled seillings, plate heat exchangers,..). Features and Benefits: The temperature control valve provides pressure independent regulation of flow while also providing flow limiting system balance. The valve internally contains a unique differential pressure regulator which automatically adjusts to normal changes in system pressure from valves opening and closing or changing of pump speed. As a result of maintaining a constant pressure for the control valve, valve authority is maintained at 100% allowing for precise interaction with the temperature controller and unparalleled system operation as indicated by maintenance of the highest possible coil log mean temperature difference (ΔT). The valve is easily set and adjusted to provide the precise flow required for the required control. Design calculation and commissioning effort normally required for control and balance valves are virtually eliminated because of it automatic pressure control regulator. A wide selection of actuators is available for the providing further control features the valve, making it an ideal selection for the simplest of two position control strategies or the precision required for modulating control and variable speed pump optimization. Features: stably controls flow through its range of operation unaffected by changes in system pressure 100% built-in control valve authority allows lower pump head than traditional valves and reduces energy consumption Three required valve functions; control, balance and flow limitation in one compact valve design Flow parameter is the only consideration, reducing valve selection engineering Constant regulation of flow limitation through independent pressure balancing User adjustable flow setting for maximum flow limitation Maintains linear characteristic of control voltage (0-10VDC) versus set flow rate when Danfoss proportional actuators are applied. Actuator can be set for equal percentage flow characterisitics Benefits: The valve combines two functions: Balancing & Control decreasing installation costs Through the automatic flow limiting function, On valve adjustment of flow reduces field commissioning Valve allows maximum coil and system differential temperature drops for optimum efficiency Operation costs reduced as much as 90% or more when properly applied with variable speed pumping Plug and Play for quick setup for balancing allowing immediate start up of unit Commissioning accomplished without use of specialized equipment Compact design allows installations in areas with limited space such as stand alone fan coils. 1
2 Technical Data: Nominal Diameter ½ ¾ 1" 1¼ Max flow (GPM) 3.) Diff. pressure 1.) 3 PSI - 60 PSI Max. working pressure 300 PSI Control range Acc. to standard IEC 534 control range does to infinity as Cv characteristic is linear Control valve characteristic Linear (could be converted by actuator to equal percentage) Leakage at 100 N No visable leakage For shut off function Acc. to ISO 5208 class A - no visable leakage Flow medium Water and water mixtures with secondary coolants (like glycols) 2.) for closed heating and cooling systems Medium temperature -15 F to 250 F (-10 C to 120 C) Connection Male NPT and Female solder tailpieces and gaskets or press fittings Actuator M30 x 1.5 Materials of Construction Body Brass (CuZn40Pb2 - CW 617N) O-Ring EPDM Springs W.Nr , W. Nr Cone (Pc) W.Nr Contact Seat (Pc) EPDM with Plug (Cv) CuZn40Pb3 - CW 614N water Seat (Cv) CuZn40Pb2 - CW 617N Screw Stainless Steel (A2) Flat Gasket NBR Sealing Agent Dimethacrylate Ester External Plastic parts POM Screws CuZn39Pb3 - CW 614N; W.Nr ; W.Nr ΔP across valve body P1-P3 (min~max) 2. Always confirm the application with the coolant manufacturer. 3. The max flow may be reduced with the combination of different actuators, please refer to the "recommended actuator" datasheet for more detail. Pc- Pressure controller part Cv- Control valve part 2
3 Technical Data (Cont.): Nominal Diameter 1½" 2" 2½ Max flow (GPM) Diff. pressure 1.) 4 PSI - 60 PSI Max. working pressure 250 PSI 300 PSI Control range Control valve characteristic Leakage acc. to standard IEC 534 Acc. to standard IEC 534 control range does to infinity as Cv characteristic is linear Linear (characterized by actuator to equal percentage) Max. 0.05% of Cv at 112 lbf Max % of Cv at 150 lbf Max. 0.01% of Cv at 225lbf For shut off function Acc. to ISO 5208 class A - no visible leakage - Flow medium Water and water mixtures with (secondary coolants) for closed oxygen tight systems Medium temperature -15 F to 250 F (-10 C to 120 C) Spindle Stroke, in (mm) 0.4" (10.2) 0.6" (15.2) 1" (25.4) Connection Flange - ISO 250 PSI Flange, gasket provided with valve for installation Actuator Danfoss standard Materials of Construction Body Grey iron EN-GJL-250 (GG25) Membrane EPDM W.Nr EPDM O-Ring EPDM Springs W.Nr , W. Nr W.Nr W. Nr Contact Cone (Pc) CuZn40Pb3 - CW 614N, W.Nr W.Nr NC W.Nr with water Seat (Pc) W. Nr W.Nr Cone (Cv) CuZn40Pb3 - CW 614N W.Nr NC W.Nr Seat (Cv) W.Nr W.Nr Screw Stainless Steel (A2) W.Nr Flat Gasket NBR Graphite gasket Non asbestos 1. ΔP across valve body P1-P3 (min~max) 2. Always confirm the application with the coolant manufacturer. Pc- Pressure controller part Cv- Control valve part 3
4 Recommended Actuators: Electronic Actuators for Code No. Style Power Signal 082F F H H8057 TWA-Z ABNM-Z, requires 082F1072 adapter AMV 110NL AME 110NL 24Vac On/Off 0-10 V DC 3-point floating 0-10 V DC 082H8048 AMI point 082H H3078 AME 15 QM AME 55 QM 0-10 V DC 0-10 V DC Travel Speed 1600s/in (64s/mm) 750s/in (30s/mm) 600s/in (24s/mm) 600s/in (24s/mm) 300s/in (12s/mm) 275s/in (11s/mm) 200s/in (8s/mm) Adaptable to: ½"- ¾" 1"- 1¼ 1½"- 2" 2½"- 4" 5"- 6" Maximum close off pressure for all actuators is 90psi (6.2 bar) Up to 70% of Max Flow Up to 55% of Max Flow Additional electronic actuators options are available for the. Other actuator options are modulating or floating with spring return with or without feedback. Refer to the actuator data sheet for full selection and information. Thermostatic Operators for Heating Applications, only for 1/2" and 3/4" valves* Code No. Style Description Sensor Capillary 013G5034 Valve mounted dial and sensor Built-in - RAE-K 013G5036 Valve mounted dial with remote sensor Remote 6.5ft (2m) 013G5458 FEV-Z Combined remote mounted dial and sensor Remote 26ft (8m) Required spindle extension adapter when isntalling thermostatic 003Z0248 N/A operators onto, 5 pcs. * Limited to 30% of maximum flow rate for 4
5 Ordering Information: Code No. Size Max. Flow (GPM) 003Z0302 ½" 4 003Z0303 ¾" Z0304 1" 11 Without P/T Plugs 003Z0305 1¼" Z0700 1½" 33 With P/T Plugs 003Z0710 2" 55 Tail pieces are required. Locking Ring Code No. Description 003Z0236 Locking Ring - installed to inhibit the unintentional changing of the valve setting. (For use with ½"-1¼" valves only) THREADED TAILPIECE KITS (two kits required per valve) Code No. Size Connection Type Description 003Z0282 1/2 003Z0283 3/4 003Z Z /4 TBA 1-1/2 TBA 2 NPT (Male) One Nut + One Threaded Tailpiece + One Gasket SOLDER TAILPIECE KITS (two kits required per valve) Code No. Size Connection Type Description 003Z0292 1/2" 003Z0293 3/4" 003Z0294 1" 003Z /4" TBA 1-1/2" TBA 2" Tail pieces with press fittings are available upon request. Solder One Nut + One Solder Tailpiece + One Gasket NOTE: valves and tailpiece kits sold separately. Two tailpiece kits required per valve. Ordering Example Requirement: 1/2 solder valve. Order: One (1) 003Z0312 valve and two (2) 003Z0292 1/2 solder tailpiece kits. 5
6 Ordering Information: (Cont'd) Code No. Size Max Flow (GPM) Flange Connection 003Z0702 2½" Z0703 3" 123 With P/T Plugs 003Z0704 4" Z0705 5" 396 PN16 With P/T Plugs 003Z0706 6" 638 Flange adapters and gaskets are required. ISO Flange Sets for use with Valves ISO Flanges / Gaskets Code No. Size Description D ½" D D ISO Flange D D Supplied with Valves 2½" Gasket for ISO Flange 6 6
7 Air handling unit Fan coil unit Application: The is a versatile device that can be used as an actuated or non-actuated balance valve. With an actuator mounted to the the assembly is a pressure independent control valve. Utilizing a proportioning controller, the creates a robust and stable energy management sub system using only the required flow and energy to offset facility heat transfer gains and losses. Traditional hydronic systems utilize a series of design decisions including constant speed flat curved pumps to maintain a stable system operating pressure and predictable valve and control operation. Utilization of variable speed drives on pumps creates a constantly fluctuating system pressure making valve flow unpredictable. Tuning temperature controllers becomes difficult and energy is wasted rather than saved due to the valve flow never being correct. The integrated differential pressure regulator virtually eliminates the problem of fluctuating pressures on control valve performance. The regulator immediately reacts to all changes in system pressure creating the stability to make the valve flow and control predictable. The end result is controllers and valves work as intended, not as they normally do, out of control. Energy is saved taking advantage of the greatly reduced amount of flow required for heat transfer of full valve authority for an air handling unit (AHU), fan coil, etc. With the the required designed flow to the AHU is met, subsequently simplifying the balancing of the system. This makes application of the ideal for HVAC system applications such as air handling units. Air handling units react quickly to changes in the building load and simple proportional control will not accurately regulate these systems. Using control integral action alone to adjust for this requires skill and extra commissioning to properly match the required settings to the application, sometimes over several seasons of operation. The differential pressure regulator acts as an extra sub-master controller and makes tuning the main controllers easier and less time consuming. Smaller building HVAC sub-systems such as fan coil units, or terminal unit heating coils and newer modern designs such as chilled beams or radiant cooling panels greatly benefit from application even when applied with simple thermostatic operation. The flow ranges of the are designed to correspond to flow rates typically applied in pipe sizing and selection. This makes control valve selection simple and easy; If a ¾ pipe is selected (typically between 1½ - 4 gallons per minute) select either a ½ or ¾ and set it for the required flow. No pressure calculations are required, valve authority doesn t need to be calculated and no calculations have to be performed to pre-set a balancing valve. If extra flow is determined to be required while tuning the installation, it s easy for the commissioning agent to reset the for any flow up to the rated range of the valve. The HVAC units and controllers will benefit from greatly enhanced ability to control, with no overflow. In a study of a large hotel with fan coils comparing a two position conventional control valve with static balancing from typical circuit setter style manual valves and simple on-off thermostatic control, the application of with the same type of control was shown to reduce required water flow sixty one percent even though the valve was cycled from full flow to no flow. This is because natural 7
8 Application (Cont.): pressure fluctuations and time lags in the piping system caused the conventional valve to always overflow, even though balanced. The dynamic regulator of the never allowed overflow to the coil and reduced the time lags associated with excessive flow rates. If proportional controllers were applied to properly match required flow rate to coil heat transfer, even more flow and energy could have been saved. Often times, there is no extra cost associated with application of this enhanced control as it is a normal component of most applied control systems in newer construction. allows hydronic HVAC systems to achieve the green and sustainable performance envisioned by their designers and owners. Owners benefit in significant reductions in commissioning time, energy cost in operation from reduced flow and less maintenance once the building is operating and occupied. Valve Operation/Design: Function: The combines aspects of both a differential pressure controller and a control valve into a single valve. P1 Available pressure P2 Regulated inlet pressure to control valve P3 Exit pressure of valve 1 Stuffing box 2 Spindle 3 Plastic ring 4 Control valve plug 5 Diaphragm 6 Regulator Spring 7 Regulator cone 8 Regulator seat 8
9 Differential Pressure Regulator: Flow enters the valve through the differential pressure regulator, which maintains a constant pressure difference across the control valve orifice. As pressure increases or decreases entering the valve in reaction to changes in flow and pump speed in the piping system (P1), the regulator diaphragm is balanced with the force of the spring keeping a constant pressure difference (P2-P3) between the water entering the temperature control valve and the leaving side of the valve. Whenever the pressure across the valve changes the hollow cone of the pressure regulator is displaced to a new position which brings a new equilibrium and therefore keeps the differential pressure at a constant level. The unique arrangement of the regulator always keeps pressure in equilibrium on the diaphragm. Even when the control valve completely closes, piping system static pressure is equalized with supply pipe static pressure being counter balanced by return pipe static pressure eliminating the potential damage to the regulator diaphragm found in other types of regulators. A nominal 3-5 psi differential is required from P1 to P3 for the valve and flow regulator operation. The regulator controls a range of system pressure to 60 psi differential (140 Ft. Hd.). Under normal system operation such as in variable speed pumping, as system flow is reduced, controlled pump speed reduces the system differential pressure (head) of the pump. In constant speed pumping applications reductions in system flow may result in increased system differential pressure (head) of the pump. Consult Danfoss if pump shutoff head exceeds 140 Ft. Hd. to prevent potential valve damage. 9
10 Control Valve Flow Coefficient and Characteristic, C v : STROKE STROKE 100% 80% 50% 50% 80% Q,K Q, C v 100% The linear characteristic of the valve allows for application flexibility. Stroke limitation allows the maximum flow of the valve to be adjusted. Control performance is not compromised by the stroke limitation; On-Off controls are not affected as they cycle between full and no flow; Proportional control actuators available for self calibrate aligning the valve stroke and control signal. Maintaining a linear characteristic allows for the predictability required to characterize the control signal when needed in application. Signal characterization is optimally done in the controller, but may be done through an available actuator which allows matching to the heat transfer characteristic. Flow Adjustment: Example: Red Required flow rate: 2.4 GPM Selected valve size: ½ Maximum Flow (Qmax)= 4 GPM Larger Sizes: Require adjustment with cresent wrench or allen key. Required flow from the ½"- 1¼" is easily adjusted without special tools; Remove the blue protective cap or mounted actuator on the to uncover the flow setting scale. The setting scale values of 100% (Open) to 0% (Closed) reflect flow percentages of the maximum flow capable through the sized. Adjust the required flow of the valve by lifting the grey collar and turning the collar to the percentage of required valve flow. Release the collar and the valve is set. 1 ½"- 4" Sizes Set the valve to 60% to achieve 2.4GPM through the valve. Danfoss recommends a presetting range from 20 % to 100 %. Factory presetting is 100 %. By turning the valve counter clockwise flow turning would increase the flow value while clock wise would decrease it. When valve is set to 80 % or more the red ring becomes visible. 1 ½"- 4" Sizes 5"- 6" Sizes
11 Valve Authority: Valve authority can be simply defined as the pressure drop of the control valve divided by the pressure drop of the system it serves e.g. the pipes, fittings, coils and other devices that become a part of the system. A = ΔP Valve ΔP Valve + ΔP System As a percentage ratio from 0%-100% the only operating condition that will ever allow the valve to operate with 100% authority is the laboratory condition and standardized test arrangement that is used to determine the flow coefficient (C V ) of the valve and its flow control characteristic. In standardized valve tests the pressure drop across the valve is controlled to maintain a constant pressure drop across the valve as it is operated and measured. When conventional valves are used in application the standard test conditions don t exist, pressure is not controlled on each valve, and the valve operation is influenced by the pressure drops of all of the other system components. Conventional valves show distortions to their standard test characteristics as shown. This makes tuning controllers difficult in the field if the valve has not been selected accounting for valve authority and coil heat transfer characteristics. % Branch Flow 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 0% Authority 10% 0% 20% 40% 60% 80% 100% % Valve Lift Authority 33% 50% Authority 100% were selected for 125 Feet of Head, and the 5 PSI rule were applied, then the authority calculation would be; A = ΔP V ΔP V + ΔP S ΔP V = 5 x 2.31 = ΔP S = = A = = or 9.2% A conventional valve with an equal percentage characteristic functions as if it is a linear valve in this system! The integrated differential pressure regulator of the essentially creates the same operating condition utilized for standardized valve rating tests in the field overcoming the hydraulic effects of the piping system components through its active control regulation. The linear characteristic of the valve is maintained as linear in the standards lab and the field. Enhanced range of control is achieved by limiting the stroke of the control valve to balance instead of an extra internal orifice which would reduce the control valve authority at low flows. When an equal percentage characteristic is required for superior modulating control, the control signal from the controller should be scaled. Either an actuator that allows user scaling to fit the proper control signal characteristic to the controlled coil heat transfer characteristic is applied, or a simple math routine is implemented in the controller to modify the normally linear output of the proportional control algorithm to the complementary signal required for the coil. The coil design and selection and thus the hydronic system design that follows it is the determining factor in linearizing the control signal, with low water side design ΔT (10 F -20 F) having characteristics that are highly curved, and high ΔT (60 F) as found in high efficiency condensing boiler hot water system design more linear characteristics. Your Danfoss hydronic system professional is your technical resource for assistance should you require more knowledge in this area. Rules of thumb have been utilized over the years with recommendations such as Utilize a 5 psi pressure drop for valve flow coefficient selection. The pressure drop of a system is equal to the operating head of the pump at design conditions. As an example if a pump 11
12 Service/Installation: Typical hydronic system design recommendations and specifications for coil application typically require components for coil isolation, test and balance pressure and temperature measurement, union pipe connection and a dirt and sediment strainer. In addition, it is considered good practice to provide flexible connections to the coil to ease Installation time and allow for minor positioning adjustment of the piping system and any expansion or contraction issues. Typical System Design The coil package allows for all required piping connections and is available in several configurations adaptable to all project installations. In addition, it is delivered to the installing agency packaged and tagged for the specific coil installation. The coil and control devices are easily serviceable through the included ball service valves, and ease installation through the variety of union tail piece sizes and pipe configurations, reducing the required fittings from larger riser piping sizes to that for the smaller coil branch piping. When a strainer is included, the optional capped ball drain valve allows for hose connection and back flushing of the strainer. Pressure/Temperature reading ports allow all commissioning measurements to be read and recorded. The actuator for the is a standard M30 x 1.5 connection with 5.5 mm lift allowing for a variety of actuators to be applied. Should service to the control valve packing ever be required, the features a back seating plug design that allows for the packing to be removed and replaced without removal of the valve from the system. The may also be fitted with an optional manual service handle. Under normal operation, the connected actuator shields the flow setting mechanism and prevents unauthorized adjustment. As an added precaution, the flow setting mechanism can be locked with an optional locking ring to prevent tampering with flow settings. The locking ring is inserted in a groove below the scale. The locking ring hinders the ability for the grey plastic setting ring to lift ensuring no possible changes to the s setting. 12
13 Typical Specification: Revised Construction Specification Institute standard numbering is utilized. The specifier is advised to coordinate product provision with other specialty specification areas as more than one may apply. The model for this specification and suggested placement is based on the Unified Facilities Guide Specifications downloadable from the Whole Building Design Guide web site (www. wbdg.org) and found under the Documents & References specifications library. The WBDG web site is offered as an assistance to the building community by the National Institute of Building Sciences (NIBS) through funding support of several US government agencies. SECTION DIRECT DIGITAL CONTROL FOR HVAC AND OTHER LOCAL BUILDING SYSTEMS PART 2 PRODUCTS 2.6 AUTOMATIC CONTROL VALVES Valves shall have stainless-steel stems and stuffing boxes with extended necks to clear the piping insulation. Valve bodies shall meet ASME B16.34 or ASME B16.15 pressure and temperature class ratings based on the design operating temperature and 150 percent of the system design operating pressure. Unless otherwise specified or shown, valve leakage shall meet FCI 70-2 Class IV leakage rating (0.01 percent of valve Kv). Unless otherwise specified or shown, valves shall be two way pressure independent globe-style bodies. Unless otherwise specified: a. bodies for valves 2 inches and smaller shall be brass or bronze, with union ends b. bodies for valves 2 to 3 inches shall be of brass, bronze or iron. c. bodies for valves 2.5 inches and larger shall be provided with flanged-end connections. d. valve and actuator combination shall be normally open or normally closed as shown Two-Way Pressure Independent Globe Valve Two-way modulating valves used for liquids. The valve shall be two way globe style with integrated differential pressure control regulator. Where indicated modulating proportional valve application shall utilize controller or actuator to match required control signal to complement controlled coil heat transfer characteristic for linear control. The valve shall; a. provide integrated pressure regulator; regulator to control pressure across control valve orifice. b. provide regulator incorporating EPDM diaphragm, stainless steel spring and pressure control disc. Pressure control seat shall be brass construction with vulcanized EPDM. c. provide counterbalance of supply pipe pressure to return pipe pressure across diaphragm to prevent diaphragm damage when control valve is closed d. provide user adjustable maximum flow within valve control range; Adjustment method shall indicate percentage of valve flow range and utilize spring locked method of adjustment. e. regulate internal control valve differential pressure to provide 100% control valve authority. f. shall have linear flow characteristic. g. provide back seated globe design to allow service of packing under pressure without leakage. h. provide entering to leaving (P1-P3) pressure control across valves ½ ¾ in size from 3PSI 60PSI. i. provide entering to leaving (P1-P3) pressure control across valves 1 1¼ in size from 3PSI 60PSI. j. provide entering to leaving (P1-P3) pressure control across valves 1½ 2 in size from 4PSI 60PSI. k. provide union connections l. utilize stainless steel internal trim with brass globe and seat. m. utilize threaded actuator connection n. flow requirements shall be sized to provide nominal body selection no more than one size smaller to corresponding nominal pipe connection. a. ½ bodies shall be utilized for ½ and may be utilized for ¾ pipe connection and flow less than 4 GPM. b. ¾ bodies may be utilized for ¾ pipe and may be applied to 1 pipe connection with flow less than 6.6 GPM. c. 1 bodies may be utilized for 1 pipe and may be applied to 1¼ pipe connection with flow less than 11 GPM. d. 1¼ bodies may be utilized for 1¼ and may be applied to 1½ pipe connection with flow less than 17.5 GPM. e. 1½ bodies may be utilized for 1½ pipe and may be applied to 2 pipe connection with flows less than 33 GPM. f. Flows less that 55 GPM may use 2 bodies. g. Flows less than 88 GPM may use 2-1/2 bodies. h. Flows less than 123 GPM may use 3 bodies. i. Flows less than 167 GPM may use 4 bodies. j. Flows less than 396 GPM may use 5 bodies. k. Flows less than 638 GPM may use 6 bodies. 13
14 Typical Specification (Cont.): Duct-Coil and Terminal-Unit-Coil; Hot and Chilled Water Systems Control valves utilized for controlled flows shall be proportionally modulated. Control valve shall be integrated into coil assembly package. Coil assembly package shall conform to requirements of other common valves as specified in Section Common Piping For HVAC. Coil assembly package shall; a. provide integrated ball valve and wye pattern strainer. Strainer shall be #20 mesh. Strainer valve shall provide pressure and temperature measurement port with integrated positive shutoff gland seal. Strainer valve shall have plugged ¼ female NPT accessory port. Strainer valve shall provide integrated ¼ ball drain valve with cap and common hose connection. Strainer valve shall provide integrated union connection and tailpiece. Strainer valve shall be provided to match flow requirements for connected control valve. b. provide union connection entering and leaving piping of coil. Union connection fitting shall include three accessory ¼ female NPT tapped ports for test and other HVAC devices. Provide pressure and temperature measurement port with integrated positive shutoff gland seal in unions entering and leaving coil. Provide manual air vent in union leaving coil. Provide ¼ threaded plugs in all unused union ports. Provide union nut, tailpiece and o-ring seal, or appropriate connectors to flexible piping. c. provide ball shutoff valve with integrated union. Valve shall provide pressure and temperature measurement port with integrated positive shutoff gland seal. Valve shall have plugged ¼ female NPT accessory port. Provide union nut, tailpiece and o-ring seal, or appropriate connectors to flexible piping. d. provide flexible piping for connection to coil. Piping shall be configured such that unions are hard mounted to coil either directly or with elbows as appropriate to allow straight flexible connection without ninety degree change in direction. Flexible pipe shall be mounted between coil union and control valve or strainer valve. 14
15 Dimensions: ½"- 1¼" L1 H3 H4 H2 H1 TWA-Z + ABNM + AMV (E) 110 NL + AMI Valve size ½ ¾ 1 1 ¼ Dimensions, in (mm) L1 L2* H1 H2 H3 H (65) 3.23 (82) 4.09 (104) 5.12 (130) 4.69 (119) 5.60 (142) 6.82 (173) 8.12 (206) 2.95 (75) 3.03 (77) 3.5 (88) 4.02 (102) 0.98 (25) 1.30 (33) 1.65 (42) 1.97 (50) 4.33 (110) 4.53 (115) 5.12 (130) 5.71 (145) 5.71 (145) 5.91 (150) 6.50 (165) 7.09 (180) Weight lb (kg) 1.06 (0.50) 1.43 (0.65) 3.20 (1.45) 4.87 (2.20) *L1, Length varies with selected tailpiece. Dimensions shown are approximate and should be verified to application and selected valve kit 15
16 Design: 1. Shut off screw 2. Main spring 3. Membrane 4. DP cone 5. Seat 6. Valve body 7. Control valve cone 8. Locking screw 9. Scale 10. Stuffing box 11. Spindle 1½"- 2" 2½"- 4" 16
17 Dimensions: 1½"- 2" L1 AME 15 QM + H2 b H1 H5 Valve size 1½ 2 Dimensions, in (mm) L1 H1 H2 H5 4.3 (110) 5.1 (130) 7.6 (192) 7.6 (192) 6.9 (174) 6.9 (174) 12.4 (315) 12.4 (315) Weight lb (kg) 15 (6.9) 17 (7.8) *L1, Length varies with selected tailpiece. Dimensions shown are approximate and should be verified to application and selected valve kit 2½ " - 4" AME 15 QM + Valve size 2 ½ 3" 4" Dimensions, in (mm) L1 H1 H2 H (290) 12.2 (310) 13.8 (350) 9.2 (233) 9.3 (236) 9.8 (249) 6.8 (172) 7.0 (177) 7.4 (187) 14.7 (373) 14.8 (376) 15.3 (389) Weight lb (kg) 84 (38) 99 (45) 126 (57) 17
18 Design (Cont.'d): 1. Valve body 2. Valve seat 3. DPC cone 4. Cv cone 5. Controller casting 6. Rolling diaphragm 7. Adjusting screw 8. Bellow for pressure relief on DPC cone 5" 6" 18
19 Dimensions (Cont.): 5" 6" AME 55 QM + 5" AME 55 QM + 6" Valve size 5" 6" Dimensions, in (mm) L1 H1 H2 H (400) 18.9 (480) 9.1 (232) 10.6 (268) 20.4 (518) 18.3 (465) 20 (507) 20.4 (518) Weight lb (kg) 188 (85.3) 304 (138) 19
20 Danfoss can accept no responsibility for possible errors in printed materials and reserves the right to alter its products without notice. All trademarks in this material are property of the respective companies. Danfoss and Danfoss logotype are trademarks of Danfoss A/S. All rights reserved. Master Distributor Indianapolis, IN Toll Free: Tel: , Fax: Danfoss Baltimore, MD Tel.: , Fax:
Pressure Independent Control Valve AB QM, ½ thru 2 2½ thru 4 5 thru 10 Valve Size
Features and Benefits Danfoss 2016.04 The AB QM temperature control valve provides pressure independent regulation of flow while also providing flow limiting system balance. The valve internally contains
More informationPressure independent balancing and control valve
Pressure independent balancing and control valve AB-QM DN 10-150 AB-QM valve equipped with an actuator is a control valve with full authority and automatic balancing function - flow limiter. Typical applications
More informationPressure independent balancing and control valve AB-QM DN
Pressure independent balancing and control valve AB-QM DN 10-150 AB-QM valve equipped with an actuator is a control valve with full authority and automatic balancing function - flow limiter. Typical applications
More informationPressure independent balancing and control valve AB-QM DN
Data sheet Pressure independent balancing and control valve AB-QM DN 10-250 The AB-QM valve equipped with an actuator is a control valve with full authority and an automatic balancing function / flow limitation.
More informationCombined automatic balancing valve AB-PM valve DN 10-32, PN 16
Data sheet Combined automatic balancing valve AB-PM valve DN 10-32, PN 16 Description AB-PM is a combined automatic balancing valve. It features three function in compact valve body: 1. Differential pressure
More informationProduct Sheet Pre-Fabricated Flushing Bypass Assembly for Plant Applications Hero Plant DN15-150
Product Sheet Pre-Fabricated Flushing Bypass Assembly for Plant Applications Hero Plant DN15-150 Description Hero Plant is a pre-fabricated, flushing bypass arrangement for balance, control, isolation,
More informationProduct Sheet Pre-Fabricated Flushing Bypass Assembly for Terminal Applications Mini-Flush 40
Product Sheet Pre-Fabricated Flushing Bypass Assembly for Terminal Applications Mini-Flush 40 Description Miniflush40 is a pre-fabricated, flushing bypass arrangement for balance, control, isolation, and
More informationAutomatic balancing valves ASV-PV DN (3rd gen.)
Automatic balancing valves ASV-PV DN 50-100 (3rd gen.) Description / Application Partner valve ASV-PV DN 50 ASV-PV DN 65-100 MSV-F2 DN 50-100 ASV balancing valves are used for dynamic hydronic balance
More informationCombined automatic balancing valve AB-PM valve DN 15-25, PN 16
Data sheet Combined automatic balancing valve AB-PM valve DN 15-25, PN 16 Description AB-PM is a combined automatic balancing valve. It features three function in compact valve body: 1. Differential pressure
More information3 & 4-Way Rotary Valves
Applications: 3-way Valve 4-way Valve The ESBE 3 and 4-Way rotary valves type F are designed for mixing or diverting applications on heating and cooling systems. The valves are capable of controlling and
More informationPre-Fabricated Flushing Bypass Assembly for Plant Applications Hero Plant DN15-150
Pre-Fabricated Flushing Bypass Assembly for Plant Applications Description Hero Plant is a pre-fabricated, flushing bypass arrangement for balance, control, isolation, and operation of plant devices. Flow
More informationInnovation + Quality. Valves, controls + systems Balancing and Control Valves
Innovation + Quality Valves, controls + systems Balancing and Control Valves Cocon Q Pressure independent control valve Product specification Size: L1 L2 H1 H2 ½, ½ LF 2.75 3.9 2.0 1.9 ¾ LF 2.9 4.2 2.0
More informationCOMMERCIAL. Product PRofile
Product PRofile 2 PRODUCT OVERVIEW INtroduction At Bray International, Inc., our business is helping our customers with their flow control requirements. Our modular product line of butterfly, ball and
More informationFlow controller with integrated control valve (PN 16) AHQM - return and flow mounting
Flow controller with integrated control valve (PN 16) AHQM - return and flow mounting Description Controllers are used together with Danfoss electrical actuators: DN 15-32 with - AMV(E) 10 - AMV(E) 13
More informationInnovation + Quality. Valves, controls + systems Balancing and Control Valves
Innovation + Quality Valves, controls + systems Balancing and Control Valves Balancing and Control Valves Catalog Hydrocontrol Static Balancing Valves Recomended flow rate chart 4 Hydrocontrol VTR Static
More informationPressure Independent Control Valve Applications for Building Automation, Temperature Controls, and HVAC Two-Way Chilled Water Hot Water
Rev: 08/19/2013 (ATiMX) Features Pressure Independent Control Valve Applications for Building Automation, Temperature Controls, and HVAC Two-Way Chilled Water Hot Water The Auto Touch Independent Max (ATiMX)
More informationTechnote. Frese OPTIMA Compact DN10-DN50 - pressure independent balancing & control valve. Application. Features. Benefits.
Page of 5 Frese OPTIMA Compact DN-DN5 Application Frese OPTIMA Compact pressure independent balancing & control valve (PIBCV) is used in heating and cooling systems in applications with Fan Coil Units,
More informationSimple Set COMMERCIAL. Pressure Independent Control Valves 2 Way 1/2-2 02/16/18 COMMERCIAL
The Bray Simple Set is a threaded pressure independent control (PIC) valve designed for a wide variety of hot water and chilled water control applications. The SS Series combines high rangeability control
More informationFlow controller with integrated control valve (PN 16) AHQM return and flow mounting
Data sheet Flow controller with integrated control valve (PN 16) AHQM return and flow mounting Description DN 15-32 DN 40, 50 DN 50-100 DN 125 DN 150 DN 200, 250 AHQM is a self-acting flow controller with
More informationSpring Achieve System Balance Without All The Spin. PICCV. Complete Details Inside!
Spring 2005 Achieve System Balance Without All The Spin. PICCV Complete Details Inside! Valve Selection Has Never Been Easier! Simply choose the smallest PICCV that can satisfy the flow rate of your system.
More informationpressure independent characterized control tm
5 pressure independent characterized control tm valves (PICCV ) PICCV reacts to pressure variations, performing a continual balancing function to maintain system performance at varying loads. Wide range
More informationVE-S_15-32 Pressure Independent Balancing & Control Valves
Page 1 of 9 VE-S_15-32 Pressure Independent Balancing & Control Valves (PIBCV) is used in heating and cooling systems in applications with Fan Coil Units, Chilled Beams or other terminal unit applications.
More informationFeatures Globe Valve 2-Way & 3-Way Assembly Features:
Rev: 10/22/13 Features Globe Valve 2-Way & 3-Way Assembly Features: DG Series Automated Applications for Building Automation, Temperature Controls, HVAC Two-Way and Three-Way Assemblies Chilled Water Hot
More informationTerminator PICV. Technical Manual
Terminator PICV Technical Manual Table of Contents Introduction 1 Advantages and Ease of Use 1 Applications examples 2 Technical specifications Start Up Charts 6 Start Up Charts 7 Start Up Charts 8 Flow
More informationPIC-V Valve... 1 Unimizer (1/2 to 3 )... 2 Unimizer (4 to 6 )... 3 Automizer... 4 MVP Valve... 5
PERFORMANCE SPECIFICATIONS PIC-V Valve... 1 Unimizer (1/2 to 3 )... 2 Unimizer (4 to 6 )... 3 Automizer... 4 MVP Valve... 5 PIC-V Valve 1. PRESSURE INDEPENDENT ACTUATED BALL VALVES AND CARTRIDGE (PIC-V)
More information2-Way & 3-Way Non Spring Return Characterized Ball Valves
VCB30 Series Revision Date June 6, 2014 2-Way & 3-Way Non Spring Return Characterized Ball Valves General The VCB30 Series electric rotary-motion actuatordriven characterized ball valves are designed specifically
More informationATi Max Series. Pressure Independent Control Valves 2 Way 2-1/2-6
The Auto Touch Independent Max (ATiMX) valve brings pressure independent control technology to valves up to 6 and flow rates up to 468 GPM. It is a state-of-the-art control valve combining a high quality/
More informationFHV control valves are flexible to use, easily installed and are available in two versions:
FHV-A/FHV-R Application: FHV-A FHV-R The floor-heating valve (FHV) provides an economical method of incorporating a radiant floor heating system into an existing hot water or radiator system. FHV self-acting
More informationAVQMT. AVQT controller can be combined with AVT or STM thermostatic actuators.
Data sheet Flow and temperature controller with / without integrated control valve (PN 25) AVQT - flow and temperature controller AVQMT - flow and temperature controller with integrated control valve Description
More informationProduct Catalog. Precision Control DeltaPValves. guaranteed delta T 10-year warranty made in the USA
Product Catalog Precision Control DeltaPValves guaranteed delta T www.flowcontrol.com 10-year warranty www.flowcontrol.com made in the USA P.O. Box 848 18715 141st Ave NE Woodinville, Washington 98072
More information20 to 150 mm 2-Way Automatic Flow Balancing Control Ball Valves
VFB30 Series Issue Date February 1, 2016 20 to 150 mm 2-Way Automatic Flow Balancing Control Ball Valves Low Torque Facilitates the use of smaller, less expensive directmount rotary-motion actuators Extends
More informationFlow-compensated temperature controller AVTQ DN 15
Data sheet Flow-compensated temperature controller AVTQ DN 15 Description AVTQ is a self-acting flow-compensated temperature controller primarily for use in district heating systems with plate heat exchangers
More informationFlow Data for NIBCO Circuit Balancing Valves 1/2 to 2 (Figure Number 1710)
NIBCO INC. WORLD HEADQUARTERS 1516 MIDDLEBURY ST. ELKHART, IN 46516-4740 USA PHONE: 574.295.3000 FAX: 574.295.3307 WEB: www.nibco.com INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS Flow Data for NIBCO
More informationSECTION Pressure & Temperature Control
16 Pressure & Temperature Control ARMSTRONG PRODUCT CATALOGUE 70 Pressure Reducing s Pressure Reducing s Armstrong pressure reducing valves (PRVs) and temperature regulators help you manage steam, air
More informationAutoFlow. Automatic Flow Control Valves
AutoFlow Automatic Flow Control Valves IMI FLOW DESIGN / AutoFlow / F010 Automatic Balancing Brochure Benefits of Automatic Balancing System equipment, such as chillers and individual terminal units, is
More informationAutomizer Combination Control Valves
Combination Control Valves Recommended Applications Where actuated valves and balancing valves are used to control the flow For VAV boxes, fan coil units and terminal boxes Where space is tight Absolute
More informationPRESSURE INDEPENDENT CONTROL VALVES (epiv & PICCV )
7 PRESSURE INDEPENDENT CONTROL VALVES (epiv & PICCV ) Pressure independent valves compensate for pressure variations, performing a continual balancing function to maintain system performance at varying
More informationSECTION METERS AND GAGES FOR PLUMBING PIPING
PART 1 GENERAL 1.01 SECTION INCLUDES A. Positive displacement meters. B. Flow meters. SECTION 22 0519 METERS AND GAGES FOR C. Pressure gages and pressure gage taps. D. Thermometers and thermometer wells.
More informationSeated valves (PN 16) VRB 2 2-way valve, internal and external thread VRB 3 3-way valve, internal and external thread
Data sheet Seated valves (PN 16) VRB 2 2-way valve, internal and external thread VRB 3 3-way valve, internal and external thread Description Combinations with other actuators could be seen under Accessories.
More informationDARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES
SECTION 15100 VALVES PART 1 DESIGN DIRECTIVE 1.1 SUMMARY A. This Section includes general duty valves common to most mechanical piping systems, special duty valves are specified in individual piping system
More informationSECTION PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY
SECTION 230533 - PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Pressure gages. 2. Pressure gage taps. 3. Thermometers. 4. Thermometer supports. 5. Test plugs. 6. Static pressure
More information2006 Product Range Overview. Belimo Project: One Bellevue Center, Seattle, Washington
2006 Product Range Overview Belimo Project: One Bellevue Center, Seattle, Washington Actuator Product Range Spring Return TF 18 in-lb [2 Nm] Approx. 4.5 sq. ft. LF 35 in-lb [4 Nm] Approx. 8 sq. ft. NF
More informationBrown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION HVAC&R VALVES
SECTION 23 05 23 HVAC&R VALVES PART 1 - GENERAL 1.1 SUMMARY: A. Section includes valves for building services piping. 1.2 GENERAL VALVE APPLICATION REQUIREMENTS: A. Provide valve handle extensions that
More informationDistributed By: M&M Control Service, Inc
Control Valves DESIGN & OPERATION Description A control valve is a device capable of modulating flow at varying degrees between minimal flow and full capacity in response to a signal from an external control
More informationP2050S-030, 1/2, Electronic Pressure Independent Valve Stainless Steel Ball and Stem, Female NPT Ends
P2050S-030, 1/2, Electronic Pressure Independent Valve Stainless Steel Ball and Stem, Female NPT Ends Application Water-side control of heating and cooling systems for AHUs and water coils. Equal Percentage/
More informationPressure Independent Control Series
Pressure Independent Control Series Two-Way, Brass Valve Bodies, -Inch to 2-Inch, ANSI 250 to 1-1/4 Inch NC - to 1-1/4-Inch NO 1- to2-inch NO Description Features Application Product Numbers and Ordering
More informationVE VVG Series Electronic Two-way Valves Normally Closed
VE VVG Series Electronic Two-way s Normally Closed Document No. 155-112P25 VE VVG-1 Description The VE VVG electronic two-way valves control the flow of water or glycol solutions. The electronic actuator
More informationTechnote. Frese OPTIMIZER - pressure independent 4-pipe coil control unit. Application. Benefits. Features.
Page of 7 Application control unit, in conjunction with the associated hydraulic set provides a complete pressure independent balancing and control group for efficient and effective individual room or
More informationCBV Series. Circuit Balancing Valves
CBV Series Circuit Balancing Valves FILE NO: 36.10IN DATE: Dec. 15, 2010 SUPERSEDES: 36.10IN DATE: Nov. 05, 2009 CBV Series Circuit Balancing Valves - Introduction Circuit balancing valves (CBVs) combine
More informationActuator ABNM A V Proportional For Use with RA2000 Valves
Actuator ABNM A5 0-10 V Proportional For Use with RA2000 Valves Application First-Open function (NC versions) Compact size, small dimensions 24V AC power source Position indicator Noiseless and maintenance-free
More information1.1 PURPOSE A. This section is intended to define the general installation and minimum product requirements for hydronic and steam valves.
Date Description of Change Pages / Sections Modified ID 6/15/16 Entire document - mgl44 PART 1 - INTRODUCTION 1.1 PURPOSE A. This section is intended to define the general installation and minimum product
More informationManual presetting valves LENO MSV-BD
Manual presetting valves LENO MSV-BD Description LENO MSV-BD is a range of manual valves for balancing flow in heating, cooling and domestic hot water systems. LENO MSV-BD is a combined presetting and
More informationDESCRIPTION 9.4 G 3/4"M
DESCRIPTION Six-way ballvalve for HVAC 4 pipes applications to automatically carry out the winter-summer change-over or, potentially, to manage radiant ceilings, fan coils and chilled beams. DIMENSIONS
More informationHarmony Installation, Operation and Maintenance
Harmony Installation, Operation and Maintenance IMI FLOW DESIGN / Installation - Maintenance / F402.0 Harmony IOM Harmony Technical Description Application: HVAC, Chilled and Hot Water Hydronic Systems
More informationPressure independent control valve with integrated flow limiter AVQM (PN 16) - return and flow mounting
Data sheet Pressure independent control valve with integrated flow limiter AVQM (PN 16) - return and flow mounting Description Controllers are used together with Danfoss electrical actuators: AMV 0 1)
More informationFigure 1710 Flow Data
AHEAD OF THE FLOW Figure 1710 Flow Data Circuit Balancing Valve Why balance your system? Whether a system is designed for heating or chilling it must be properly adjusted and balanced for optimum design
More informationSeated valves VF 2, VL 2-2-way VF 3, VL 3-3-way
Data sheet Seated valves VF 2, VL 2-2-way VF 3, VL 3-3-way Description The valves provide a quality, cost effective solution for most water and chilled applications. These valves may be used with glycol
More informationV5000, V5010 Kombi-3-plus BALANCING AND SHUTOFF VALVES
V5000 Kombi-3-plus RED V5000, V5010 Kombi-3-plus BALANCING AND SHUTOFF VALVES CONTENTS PRODUCT DATA Overview... 2 Design... 2 Materials... 2 Application... 2 Features... 2 Specifications... 2 Ordering
More informationZone Valves and Parts (Honeywell)
28/11/14 B49 Zone Valves - Two Way Fan Coil Zone Valves and Parts (Honeywell) Two-way Fan Coil Valve, the VU53 high pressure zone valves are used to control the flow of hot or chilled water in commercial
More informationCombi valves PN 16 with flanged connections
4 315 ACVATIX Combi valves PN 16 with flanged connections Pressure Independent Combi Valves VPF43.. With integrated pressure differential controller Valve body made of gray cast iron GJL-250 DN 50, DN
More informationTechnote. Frese OPTIMA - Pressure independent control & balancing valve. Application. Features. Benefits.
Page 1 of 12 Application pressure independent control valve (PICV) is used in heating and cooling systems in applications with Fan Coil Units, Air Handling Units or other terminal unit applications. provides
More informationFlow controller (PN 25) AVQ - return and flow mounting
Data sheet Flow controller (PN 5) - return and flow mounting Description is a self-acting flow controller primarily for use in district heating systems. The controller closes when set max. flow is exceeded.
More informationWritten By : Simon Teo B. ENG (HONS)
Written By : Simon Teo B. ENG (HONS) The Ultimate Control Valves Used in Hydronic HVAC System FlowCon International pressure independent flow control valves () are changing the way control valves function
More informationSECTION VALVES PART 1 -GENERAL
SECTION 1571 0 VALVES PART 3- EXECUTION General Shut-off Valves Balancing Valves Drain Valves RELATED WORK Section 15430- Plumbing Specialties Section 15450- Plumbing Equipment PART 1 -GENERAL SCOPE This
More informationVA, VF, and VS Series Direct Mounted Globe Valve Assemblies. Application. Features
TAC 1354 Clifford Avenue P.O. Box 2940 Loves Park, Illinois 61132-2940 www.invensysibs.com Two-Way and Three-Way Globe Valve Assemblies with 220 lbf Linear (979 N) Spring Return DuraDrive Actuators Submittal
More informationGRINNELL MODEL CB800 CIRCUIT BALANCING VALVE INSTALLATION & SETTING HANDBOOK
Technical Services 866-500-4768 +-40-78-8220 GRINNELL MODEL CB800 CIRCUIT BALANCING VALVE INSTALLATION & SETTING HANDBOOK AUGUST 20 IH-4500 Table of Contents Contents General Description.... 3 Dimensional
More informationPowers Controls Powertop Two-Way Valves Normally Open
Powers Controls Powertop Two-Way s Normally Open VP 658-5 Description The VP 658 normally open valves are pneumatically operated valves designed to control the flow of both water and steam. Features Stainless
More informationPressure Independent Control Series
Pressure Independent Control Series Two-Way, Brass Valve Bodies, 1/2-Inch to 2-Inch, ANSI 250 1/2 to 1-1/4 Inch NC 1/2- to 1-1/4-Inch NO 1-1/2 to2-inch NO Description Features Application Product Numbers
More informationVG9000 Flanged Valves
VG9000 Flanged Valves DN15..., PN6 and PN10 Product Bulletin This improved VG9000 Series cast iron flanged valves are designed primarily to regulate the flow of water and low pressure steam in response
More informationTDU.3 floor distribution unit SK
SK General description and application The is intended for two pipe horizontal heating systems and includes connecting, measuring, regulating and distribution functions. The TDU.3 is easily installed on
More informationTable of Contents Introduction 3 Chapter 2: Operation 4 Chapter 3: Components 5 Chapter 4: Specifications 8
Table of Contents Introduction 3 Application 3 Chapter 2: Operation 4 Manifold Function 4 Chapter 3: Components 5 Required Parts 5 Manifold without Actuators without Pressure Bypass Kit 5 Pump Kit (QHMPK_)
More informationW91/W94 Series TEMPERATURE REGULATORS. Self-Operated Temperature Regulators. Design & Operation W91 Non-Indicating W94 Dial Thermometer
Design & Operation W91 Non-Indicating W94 Dial Thermometer Watson McDaniel reserves the right to change the designs and/or materials of its products without notice. 2010 Watson McDaniel Company CAPILLARY
More informationSECTION METERS AND GAGES FOR HVAC PIPING
PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions Specification Sections, apply to this Section. 1.2 SUMMARY A. This
More informationSeated valves (PN 6) VL 2 2-way valve, flange VL 3 3-way valve, flange
Data sheet Seated valves (PN 6) VL 2 2-way valve, flange VL 3 3-way valve, flange Description VL 2 VL 3 VL 2 and VL 3 valves provide a quality, cost effective solution for most water and chilled applications.
More informationVZ*19* VZ219E, VZ319E, VZ419E VZ219C, VZ319C, VZ419C
VZ219E, VZ319E, VZ419E VZ219C, VZ319C, VZ419C SPECIFICATIONS Design PN16, Two-way, Three-way and Three-way with bypass (Linear operation) Function.... Normally Closed (A-AB). [Without actuator fitted]
More informationHERZ 7217 V. Integral Fixed Orifice Control Valve HERZ 7217 V. Data sheet 7217 V, Issue Size in mm. STRÖMAX Fig No DN L Lm Rp H SW kv kvs
HERZ 7217 V Integral Fixed Orifice Control Valve Data sheet 7217 V, Issue 1011 Size in mm STRÖMAX Fig No DN L Lm Rp H SW kv kvs TS-V LF 1 7217 50 15 83 28,5 1/2 41 27 0,07-0,45 0,48 TS-V MF 1 7217 59 15
More informationDWS 41. Installation Data 44 Performance Specs DWS & DW-PRV Series
IRRIGATION Title Description Details Page Intro 3 2000 Series 4 Model 2000 Solenoid 1 3 12 Model 2000 Solenoid 4 8 15 Model 2030 Low Power Solenoid 1 3 17 Model 2030 Low Power Solenoid 4 8 19 Model 2160
More informationMercy Hospital of Buffalo Catholic Health System 2 nd Floor Patient Holding Center 3 rd Floor Locker Rooms Shaflucas Architects, PC Project No.
SECTION 23 22 13 STEAM AND CONDENSATE PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 1 Specification
More informationVDL : 2-way regulating valve for dynamic hydronic balancing, PN 25, Valveco compact
Product data sheet 9.1 7.003 VDL 010...00: 2-way regulating valve for dynamic hydronic balancing, PN 2, Valveco compact How energy efficiency is improved Automatic dynamic hydronic balancing with the SAUTER
More informationBALANCING VALVES FOR BUILDING
ICV TOTAL CONTROL INSIDE BUILDINGS IC Valves (Nanjing) Co., Ltd. Changfa Centre Bldg A, G Zhongshan East Road Nanjing 210002. China 20-08 Copyright IC Valves (Nanjing) Co., Ltd. Tel: +86 8320 0100 +86
More information200 Series - Plastic Hydraulic/Electric Control Valves. Water Control Solutions
- Plastic Hydraulic/Electric Control Valves Water Control Solutions Plastic Hydraulic/Electric Control Valves for residential, commercial and agricultural irrigation systems. The BERMAD plastic control
More informationBalancing Basics. Mike Weisman, ASHRAE Treasurer. ASHRAE Golf Outing: May 18 th, 2018! HEATHERWOODE
Balancing Basics Mike Weisman, ASHRAE Treasurer ASHRAE Golf Outing: May 18 th, 2018! HEATHERWOODE Agenda: Why balance? Manual Balancing Valves Manual Balancing Process Automatic Flow Controllers Partial
More informationAbout Us Our Mission Table of Contents 04 Automatic Flow Limiting Valves 06 Manual Balance Valves 08 2-Way & 3-Way Actuated Ball Valves
HVAC CATALOG About Us Griswold Controls pioneered Automatic flow limiting control with the introduction of its stainless steel flow cartridge in 1960. Over 55 years later, our innovation, quality and reliability
More information36486_HVAC-Catalog_r1.pdf 1 1/12/17 11:57 AM HVAC CATALOG
HVAC CATALOG About Us Griswold Controls pioneered Automatic flow limiting control with the introduction of its stainless steel flow cartridge in 1960. Over 55 years later, our innovation, quality and reliability
More information3-way 1/2-2 Globe Valves
Datasheet Overview Designed to work with either an electronic actuator with a 3/4-inch (20 mm) stroke, the three-way globe valves are available in ANSI Class 250 for normally closed or normally open action.
More informationFlowrite 599 Series Three-Way Valves 1/2 to 2-inch Bronze Body
Flowrite 599 Series Three-Way Valves 1/2 to 2-inch Bronze Body Document No. 155-185P25 VF 599-4 Description The Flowrite VF 599 Series ANSI Class 250 three-way valves are designed to work with either a
More informationA. Provide all HVAC specialties required to complete the installation of all HVAC systems. B. Manufacturers: Refer to individual product item.
DIVISION 23 HEATING, VENTILATING, AND AIR CONDITIONING (HVAC) SECTION 23 05 02 PART 1 GENERAL 1.01 DESCRIPTION A. Provide all HVAC specialties required to complete the installation of all HVAC systems.
More informationVE-x Plug & Seat Valve Assemblies
Page 1 of 5 Plug & Seat Valve ssemblies Features: Suitable for water or glycol mix 1½ million cycle U-cup packing cartridge Maintenance free High and low Kvs of each size ll metal movement, no plastic
More informationIron Horse ED Series Pressure Regulator
REGULATORS Applications Pressure Regulation for Steam Distribution Single Point or Multiple Use Applications Pressure Control for Steam Plants District Heating Systems Single Stage Reduction Stations Two
More informationTemperature controller AVT with safety temperature monitor STM/VG(F) (PN25)
Data sheet Temperature controller AVT with safety temperature monitor STM/VG(F) (PN25) Description Controller closes on rising temperature. TR1240 The controllers are: Type-tested acc. to EN 14597 and
More informationCALEFFI. Pre-assembled distribution manifolds for radiant panel systems. series 663 & /05 NA. Function
Pre-assembled distribution manifolds for radiant panel systems series & / NA Function Distribution manifolds for radiant panel systems are used to optimally distribute the heating fluid in floor heating
More informationThe Siemens 599 Series Ball Valve Portfolio simplifies installations and maximizes control usa.siemens.com/hvac
Two-,Three-, and Six-Way Ball Valves The Siemens 599 Series Ball Valve Portfolio simplifies installations and maximizes control usa.siemens.com/hvac Ready for the Challenge With higher close-offs, a wider
More informationProduct Instructions. Mixing Station. Features. Specifications. Materials
Mixing Station The Viega Mixing Station provides supply water temperature modulation when connected to a variety of heat sources such as conventional or condensing boilers, water heaters, or geothermal
More informationFlowCon SH mm. Adjustable Dynamic Self Balancing Valve SPECIFICATIONS
FlowCon SH 50-150mm Adjustable Dynamic Self Balancing Valve SPECIFICATIONS Pressure rating: 4000 kpa / 580 psi Temperature rating, media: -20 C to +120 C / -4 F to +248 F Material: - Diaphragm: Hydrogenated
More informationSeated valves (PN 16) VRB 2 2-way valve, internal and external thread VRB 3 3-way valve, internal and external thread
Data sheet Seated valves (PN 16) VRB 2 2-way valve, internal and external thread VRB 3 3-way valve, internal and external thread Description VRB valves provide a quality, cost effective solution for most
More informationT Series (NPT) 2-Way and 3-Way Terminal Unit Zone Valves 1/2 3/4" 1. Applications. Features. Terminal Unit Zone Valves (NPT)
Terminal Unit Zone Valves (NPT) T Series (NPT) 2-Way and 3-Way Terminal Unit Zone Valves 1/2 3/4" 1 Neptronic 2-way and 3-way terminal unit zone valves are offered in a wide range of styles and connection
More informationChangeOver6 and NovoCon ChangeOver6 - Motorized 6-port Ball Valves
- Motorized 6-port Ball Valves Description NovoCon The and NovoCon are 6-port motorized ball valves that performs a diverting function between two water circuits in 4-pipe changeover system. This diverting
More informationDifferential pressure controller (PN 16, 25, 40) AFP(-9) / VFG 2(1) return and flow mounting, adjustable setting
Data sheet Differential pressure controller (PN 16, 25, 40) AFP(-9) / VFG 2(1) return and flow mounting, adjustable setting Description The controller has a control valve, an actuator with one control
More informationTYPE ET14 TEMPERATURE REGULATOR CAST IRON, BRONZE or STEEL CONTROLS 20 to 500 F
TYPE ET14 TEMPERATURE REGULATOR CAST IRON, BRONZE or STEEL CONTROLS 20 to 500 F Temperature Regulation for Batch Process Storage Heaters (Water, Fuel Oil or Chemical) Air Heating TYPE ET14 TEMPERATURE
More informationFCU 6-PORT PICV VALVE SET MODULE BROCHURE
FCU 6-PORT PICV VALVE SET MODULE BROCHURE Copyright. February 2019 FLOCONTROL DESIGNS AND ASSEMBLES BESPOKE FCU VALVE SETS TO ADDRESS PROJECT-SPECIFIC REQUIREMENTS FloControl offers a comprehensive range
More information