Two- and three way valves VFG.. / VFGS 2 / VFU.. for self-acting thermostats and electrical actuators
|
|
- Kelley Farmer
- 5 years ago
- Views:
Transcription
1 for self-acting thermostats and electrical actuators Description VFG 2 VFG 21 (see pages 2, 3, 4) Valves for heating, district heating and cooling systems. The valves can be used with following actuators: Thermostats AFT.. Actuators AMV(E) 655, 658, 659 (from Q4 2014) Main data: DN T max 200 C 2-way valve (Normaly Open) Media: circulation water and glycolic water up to 30% Cone: VFG 2 metal/metal sealing VFG 21 soft sealing Pressure relieved VFGS 2 (see pages 5, 6) Main data: DN T max 350 C 2-way valve (Normaly Open) Media: steam Cone: metal/metal sealing Pressure relieved VFG 33 (see pages 6, 7) Main data: DN T max 200 C Media: circulation water and glycolic water up to 30% mixing pressure balanced valve Cone: metal/metal sealing VFU 2 (see page 7, 8) Main data: DN T max 150 C 2-way valve (Normaly Close) Media: circulation water and glycolic water up to 30% Cone: metal/metal sealing Pressure relieved Danfoss VD.H.I3.02 1
2 Ordering (VFG Cone: metal /metal sealing, pressure relieved. Picture DN Connections T max Code No. T max Code No. (mm) (m 3 /h) ( C) PN 16 ( C) PN 25 PN , , , Flanges acc. to EN On request On request On request for detailed temperature limits refer to pressure/temperature diagram pg 9 Technical data (VFG Nominal diameter DN value (m 3 /h) 4 6, z value acc. to VDMA ,6 0,6 0,6 0,55 0,55 0,5 0,5 0,45 0,4 0,35 0,3 0,2 0,2 PN AFT PN 25, PN AMV(E) 655, 658, 659 (from Q4 2014) 4) PN 25, Nominal pressure PN 16, 25 flanges to EN or 40, flanges to EN Flow media/temperature Pressure balance Valve body material PN 16 Circulation water / Glycolic water up to 30 % / thermo oil / C PN 25, 40 Circulation water / Glycolic water up to 30 % / thermo oil / C PN 16 PN 25 Stainless steel bellow, mat. No Grey cast iron EN-GJ-250 (GG-25) Ductile iron EN-GJS T (GGG-40. PN 40 Cast steel GP240GH (GS-C 25) Rolling diaphragm Cone material Stainless steel, mat. No mat. No Seat material Stainless steel, mat. No mat. No In combination with actuators AMV(E), values are higher if Y60 piece is removed from valve. Above operating pressure of 14 bar use of valve stem extension ZF4, ZF6 or combination piece KF2 is necessary. In order the actuator can close at max differential pressure flow velocity musn t exceed 2 m/s. 4) With adapter: Danfoss VD.H.I3.02
3 Design (VFG 1. Valve body 2. Valve seat 3. ellows 4. Valve insert 5. Diaphragm 6. Valve body extension 7. Shut off valve for water filling 8. Closing plug VFG 2 DN VFG 2 DN VFG 2 DN , T max 200 C Ordering (VFG 2 Cone: soft sealing, pressure relieved. Picture DN Connections T max Code No. (mm) (m 3 /h) ( C) PN , , , Flanges acc. to EN VD.H.I3.02 Danfoss
4 Technical data (VFG 2 Nominal diameter DN DN value (m 3 /h) 4 6, z value acc. to VDMA ,6 0,6 0,6 0,55 0,55 0,5 0,5 0,45 0,4 0,35 0,3 0,2 0,2 PN PN AMV(E) 655, 658, 659 (from Q4 2014) 4) PN Nominal pressure PN 16 or 25, flanges to EN Flow media/temperature Circulation water / Glycolic water up to 30 % / C Pressure balance Stainless steel bellow, mat. No Rolling diaphragm Valve body material PN 16 Grey cast iron EN-GJ-250 (GG-25) PN 25 Ductile iron EN-GJS T (GGG-40. Cone material Stainless steel, mat. No mat. No Seat material Stainless steel, mat. No mat. No Conical seal EPDM in combination with actuators AMV(E), values are higher if Y60 piece is removed from valve. above operating pressure of 14 bar use of valve stem extension ZF4, ZF6 or combination piece KF2 is necessary. In order the actuator can close at max differential pressure flow velocity musn t exceed 2 m/s. 4) With adapter: Design (VFG 2 1 Valve body 2 Valve seat 3 ellow 4 Valve insert 5 Diaphragm VFG 21 DN VFG 21 DN Danfoss VD.H.I3.02
5 Ordering (VFGS 2 for steam) Cone: metal/metal sealing, pressure relieved. Picture DN T max Code No. T max Code No. Connections (mm) (m 3 /h) (m 3 /h) ( C) PN 16 ( C) PN 25 PN ,0 2, ,3 4, ,0 6, Flanges acc. to EN Valves with flow divider for noise reduction (see accessories) for detailed temperature limits refer to pressure/temperature diagram pg 9 Valve has valve body extension (VE) and pre-installed flow divider Technical data (VFGS Nominal diameter DN value (m 3 /h) 4 6, value (m 3 /h) 2,5 4,0 6, z value acc. to VDMA ,6 0,6 0,6 0,55 0,55 0,5 0,5 0,45 0,4 0,35 0,3 0,2 0,2 AFT PN 25, 40 PN ) PN AMV(E) 655, 658, 659 5) (from Q4 2014) PN 25, Nominal pressure PN 16, 25 flanges to EN or 40, flanges to EN Flow media/temperature PN 16 Steam / max. 150 C PN 25, 40 Steam / max. 350 C Steam / max. 300 C Pressure balance Stainless steel bellow, mat. No Rolling diaphragm Valve body material PN 16 PN 25 Grey cast iron EN-GJ-250 (GG-25) Ductile iron EN-GJS T (GGG-40. PN 40 Cast steel GP240GH (GS-C 25) Cone material Stainless steel, mat. No mat. No Seat material Stainless steel, mat. No Valves with flow divider for noise reduction (see accessories) In combination with actuators AMV(E), values are higher if Y60 piece is removed from valve. Above operating pressure of 14 bar use of valve stem extension ZF4, ZF6 or combination piece KF2 is necessary. 4) In order the actuator can close at max differential pressure flow velocity musn t exceed 2 m/s. 5) With adapter: VD.H.I3.02 Danfoss
6 Design (VFGS 1. Valve body 2. Valve seat 3. ellow 4. Valve insert 5. Diaphragm 6. Valve body extension 7. Shut off valve for water filling 8. Closing plug VFGS 2 DN VFGS 2 DN Ordering (VFG 3 VFG 33 (mixing valve pressure balanced) Picture DN Connections T max Code No. T max Code No. (mm) (m 3 /h) ( C) PN 16 ( C) PN Flanges acc to EN for detailed temperature limits refer to pressure/temperature ratings diagram pg 9 Technical data (VFG 3 Nominal diameter DN value (m 3 /h) 8 12, AFT PN PN PN AMV(E) 655, 658, 659 (from Q4 2014) PN 25, Nominal pressure PN 16 or 25, flanges to EN Flow media/temperature PN 16 Circ.water / Glycolic water up to 30 % / C PN 25 Circ.water / Glycolic water up to 30 % / C Pressure balance Stainless steel bellow, mat. No Valve body material PN 16,25 Ductile iron EN-GJS T (GGG-40. Cone material Stainless steel, mat. No Seat material Stainless steel, mat. No Above operating pressure of 14 bar use of valve stem extension ZF4, ZF6 or combination piece KF2 is necessary. In order the actuator can close at max differential pressure flow velocity musn t exeed 2 m/s. With adapter: Danfoss VD.H.I3.02
7 Applications (VFG 3 A A AFT06 / VFG 33 A A Heating Cooling Mixing valve used in mixing application Mixing valve used in diverting application Design (VFG 3 1 Valve body 2 Valve seat 3 ellow 4 Valve insert A A Ordering (VFU Opening valve, pressure relieved. VFU 2 (metallic sealing cone) Picture DN T Connections max Code No. (mm) (m 3 /h) ( C) PN , , , Flanges acc. to EN for detailed temperature limits refer to pressure/temperature diagram pg 9 VD.H.I3.02 Danfoss
8 Technical data (VFU Nominal diameter DN value (m 3 /h) 4 6, z value acc. to VDMA ,6 0,6 0,6 0,55 0,55 0,5 0,5 0,45 0,4 0,35 AFT.. PN AMV(E) 655, 658, 659 PN (from Q4 2014) Nominal pressure PN 16, flanges to EN Flow media/temperature Circulation water / Glycolic water up to 30 % / C Pressure balance Stainless steel bellow, mat. No Valve body material Grey cast iron EN-GJ-250 (GG-25) Cone material/conical seal Stainless steel, mat. No Seat material Stainless steel, mat. No With adapter: Design (VFU 1 Valve body 2 Valve seat 3 Valve insert 4 ellow Accessories Picture Type Note Code No. Comb. piece KF2 For combinations with thermostats 003G1398 Comb. piece KF3 Valve stem extension ZF4 Valves DN Valve stem extension ZF5 For combinations with thermostats, pressure controllers and motorised actuators Valves DN For water, steam above 200 C For oil above 200 C For water, steam or oil above 200 C 003G G G G1396 Valve stem extension ZF6 For water, steam temperatures until 200 C 003G1393 Remark: Temperature controller with thermostat AFT..: This controller can be used until operating pressure of 14 bar. If the operating pressure is higher than 14 bar the valve stem extension ZF4, ZF6 or the combination piece KF2 must be used. Flow divider for VFGS 2 (for noise reduction) DN reduced Code No ,5 20 6, , Danfoss VD.H.I3.02
9 Pressure temperature diagram Working area is below P-T line and it ends at T max for each valve VFG/VFU/VFGS PN 16 EN-GJ-250 (GG-25) Maximum allowed operating pressure as a function of media temperature (according to EN VFG PN 25 VFGS PN 25 EN-GJS-400 (GGG-40. EN-GJS-400 (GGG Maximum allowed operating pressure as a function of media temperature (according to EN VFG PN 40 VFGS PN 40 EN-GP-240-GH (GS-C 25) EN-GP-240-GH (GS-C 25) 120 Maximum allowed operating pressure as a function of media temperature (according to EN VD.H.I3.02 Danfoss
10 H H 1 H 1 Dimensions VFG(S) DN VFG DN VFG 2, VFG 21, VFGS 2 Valves VFG(S) DN with valve body extension up to 200 (300) C DN mm H Weight PN 16 / 25 27, kg 7,5 8, PN ,5 60, mm H Weight (valve with body extension) PN 16 / kg PN Danfoss VD.H.I3.02
11 Dimensions (continuous) C /2 VFU 2 DN VFG 33 DN VFG 33 valves DN mm Weight kg 10, VFU 2 valve DN mm C Weight kg 7,0 9, Comb. piece KF2, KF3 Valve stem extension ZF4, ZF5 Valve stem extension ZF6 VD.H.I3.02 Danfoss
12 Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary eady agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved. 12 Danfoss DHS-SRMT/SI VD.H.I3.02
Pressure relief controller AFA / VFG 2(1) (PN 16, 25, 40)
Data sheet Pressure relief controller AFA / VFG 2(1) (PN 16, 25, 40) Description The controller is a self-acting pressure relief controller primarily for use in district heating systems. The controller
More informationPressure reduction controller AFD / VFG 2, VFG 21, VFGS 2
Data sheet Pressure reduction controller AFD / VFG 2, VFG 21, VFGS 2 Description The controller is a self-acting pressure reducer primarily for use in district heating systems. The control closes on rising
More informationPressure reduction controller AFD / VFG 2, VFG 21, VFGS 2
Data sheet Pressure reduction controller AFD / VFG 2, VFG 21, VFGS 2 Description The controller is a self-acting pressure reducer primarily for use in district heating systems. The control closes on rising
More informationDifferential pressure controller (PN 16, 25, 40) AFP(-9) / VFG 2(1) return and flow mounting, adjustable setting
Data sheet Differential pressure controller (PN 16, 25, 40) AFP(-9) / VFG 2(1) return and flow mounting, adjustable setting Description The controller has a control valve, an actuator with one control
More informationk VS DN (mm) Connections ( C) (m 3 /h)
Data sheet Differential pressure and flow controller (PN 16, 25, 40) AFPQ / VFQ 2( - return mounting, adjustable setting AFPQ 4 / VFQ 2( - flow mounting, adjustable setting Description The controller has
More informationDifferential pressure controller AFP / VFG 2 (VFG 21)
Differential pressure controller AFP / VFG 2 (VFG 21) Description AFP VFG2 (VFG 21) is a self-acting differential pressure controller primarily for use in district heating systems. The controller closes
More informationDifferential pressure relief controller (PN 16, 25, 40) AFPA / VFG 2(1)
Data sheet Differential pressure relief controller (, 25, 40) AFPA / VFG 2() Description The controller has a control valve, an actuator with one control diaphragm and spring for differential pressure
More informationPressure reduction controllers (PN 25) AVDS - for steam AVD - for water
Data sheet Pressure reduction controllers (PN 25) - for steam AVD - for water Description Main data AVD: DN 15-50 k VS 0,4-25 m 3 /h PN 25 Setting range: 1-5 bar / 3-12 bar Temperature: - Circulation water/glycolic
More informationFlow controller (PN 25) AVQ - return and flow mounting
Data sheet Flow controller (PN 5) - return and flow mounting Description is a self-acting flow controller primarily for use in district heating systems. The controller closes when set max. flow is exceeded.
More informationDifferential pressure controller AFP / VFG 2 (VFG 21)
Differential pressure controller AFP / VFG 2 (VFG 21) Description AFP VFG2 (VFG 21) is a self-acting differential pressure controller primarily for use in district heating systems. The controller closes
More informationPressure relief controller AVA (PN 25)
Data sheet Pressure relief controller AVA (PN 25) Description AVA is a self-acting pressure relief controller primarily for use in district heating systems. The controller is normally closed and opens
More informationDifferential pressure controller AFP / VFG 2 (VFG 21)
Differential pressure controller AFP / VFG 2 (VFG 21) Description / Application AFP VFG2 (VFG 21) is a self-acting differential pressure controller primarily for use in district heating systems. The controller
More informationFlow controller (PN 16, 25, 40) AFQ / VFQ 2(1) - return and flow mounting
Data sheet Flow controller (PN 16, 5, 40) AFQ / VFQ ( - return and flow mounting Description The controller has a control valve with adjustable flow restrictor and an actuator with one control diaphragm.
More informationFlow controller with integrated control valve (PN 16) AHQM - return and flow mounting
Flow controller with integrated control valve (PN 16) AHQM - return and flow mounting Description Controllers are used together with Danfoss electrical actuators: DN 15-32 with - AMV(E) 10 - AMV(E) 13
More informationDifferential pressure relief controller AFPA / VFG 2 (VFG 21)
Differential pressure relief controller AFPA / VFG 2 (VFG 21) Description AFPA VFG2 (VFG 21) is a self-acting differential pressure relief controller primarily for use in district heating systems. The
More informationFlow Control and Differential Pressure Controller AFPQ / VFQ 2(21) - Installation in return line AFPQ 4 / VFQ 2(21) - Installation in flow line
Flow Control and Differential Pressure Controller AFPQ / VFQ 2(21) - Installation in return line AFPQ 4 / VFQ 2(21) - Installation in flow line Description / Application AFPQ VFQ AFPQ 4 VFQ The controller
More informationPressure independent control valve with integrated flow limiter AVQM (PN 16) - return and flow mounting
Data sheet Pressure independent control valve with integrated flow limiter AVQM (PN 16) - return and flow mounting Description Controllers are used together with Danfoss electrical actuators: AMV 0 1)
More informationTemperature controller AVT with safety temperature monitor STM/VG(F) (PN25)
Data sheet Temperature controller AVT with safety temperature monitor STM/VG(F) (PN25) Description Controller closes on rising temperature. TR1240 The controllers are: Type-tested acc. to EN 14597 and
More informationFlow controller (PN 25) AVQ - return and flow mounting
Data sheet Flow controller (PN 5) - return and flow mounting Description is a self-acting flow controller primarily for use in district heating systems. The controller closes when set max. flow is exceeded.
More informationFlow controller with integrated control valve (PN 16) AHQM return and flow mounting
Data sheet Flow controller with integrated control valve (PN 16) AHQM return and flow mounting Description DN 15-32 DN 40, 50 DN 50-100 DN 125 DN 150 DN 200, 250 AHQM is a self-acting flow controller with
More informationPressure relief controller for oil V22D28 (PN 16, 25)
Data sheet Pressure relief controller for oil V22D28 (PN 16, 25) Description The controller has a control valve, an actuator with one control diaphragm and a spring for pressure setting. Features: - safe
More information2 - way valve (NO), pressure relieved (PN 25) VG - external thread VGF - flange
Data sheet 2 - way valve (NO), pressure relieved (PN 25) VG - external thread VGF - flange Description VG and VGF are pressure relieved 2-way normally open (NO) valves, designed to be combined with: -
More informationButterfly valve with electrical actuator VFY-WA
Butterfly valve with electrical actuator Description Position indicator Torque limiter Complete installation from factory - ready for installation Features: Spline driven one piece shaft connected to spherically
More informationButterfly valve with electrical actuator VFY-WA
Butterfly valve with electrical actuator Description Position indicator Torque limiter Complete installation from factory - ready for installation Features: Spline driven one piece shaft connected to spherically
More informationAVQMT. AVQT controller can be combined with AVT or STM thermostatic actuators.
Data sheet Flow and temperature controller with / without integrated control valve (PN 25) AVQT - flow and temperature controller AVQMT - flow and temperature controller with integrated control valve Description
More informationTemperature controller (PN 25) AVT / VG - external thread AVT / VGF - flange
Data sheet Temperature controller (PN 25) AVT / VG - external thread AVT / VGF - flange Description AVT / VG The AVT / VG(F) controller is a self-acting proportional temperature controller developed primarily
More informationTemperature controller for heating (PN 25) AVT / VG - external thread AVT / VGF - flange
Data sheet Temperature controller for heating (PN 25) AVT / VG - external thread AVT / VGF - flange Description AVT / VG AVT / VGF The AVT / VG(F) controller is a self-acting proportional temperature controller
More informationFlow-compensated temperature controller AVTQ DN 15
Data sheet Flow-compensated temperature controller AVTQ DN 15 Description AVTQ is a self-acting flow-compensated temperature controller primarily for use in district heating systems with plate heat exchangers
More informationSeated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange
Data sheet Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange Description VF 2 VF 3 VF 2 and VF 3 valves provide a quality, cost effective solution for most water and chilled applications.
More informationSeated valves (PN 16) VF 2-2-way valve, flange VF 3-3-way valve, flange
Data sheet Seated valves (PN 16) VF 2-2-way valve, flange VF 3-3-way valve, flange Description VF 2 VF 3 VF 2 and VF 3 valves provide a quality, cost effective solution for most water and chilled applications.
More informationDifferential pressure controller with flow limitation and with integrated control valve (PN 16) AHPBM-F flow mounting, fixed setting
Data sheet Differential pressure controller with flow limitation and with integrated control valve (PN 16) AHPBM-F flow mounting, fixed setting Description The controller has a control valve with adjustable
More informationFlow controller with integrated control valve (PN 16) AVQM - return and flow mounting
Data sheet Flow controller with integrated control valve (PN 16) AVQM - return and flow mounting Description The controller has a control valve with adjustable flow restrictor, connection neck for electrical
More informationServo-operated 2/2-way solenoid valves with isolating diaphragm Type EV222B
Data sheet Servo-operated 2/2-way solenoid valves with isolating diaphragm Type EV222B EV222B is an indirect servo-operated solenoid valve programme for use in connection with contaminated or aggressive
More informationData sheet Pressure independent control valve with integrated flow limiter AVQM (PN 16) - return and flow mounting
Pressure independent control valve with integrated flow limiter AVQM (PN 16) - return and flow mounting Description Controllers are used together with Danfoss electrical actuators: - AMV 150 1) - AMV(E)
More informationSeated valves (PN 6) VL 2 2-way valve, flange VL 3 3-way valve, flange
Data sheet Seated valves (PN 6) VL 2 2-way valve, flange VL 3 3-way valve, flange Description VL 2 VL 3 VL 2 and VL 3 valves provide a quality, cost effective solution for most water and chilled applications.
More informationSeated valves VF 2, VL 2-2-way VF 3, VL 3-3-way
Data sheet Seated valves VF 2, VL 2-2-way VF 3, VL 3-3-way Description The valves provide a quality, cost effective solution for most water and chilled applications. These valves may be used with glycol
More informationAutomatic balancing valves ASV-PV DN (3rd gen.)
Automatic balancing valves ASV-PV DN 50-100 (3rd gen.) Description / Application Partner valve ASV-PV DN 50 ASV-PV DN 65-100 MSV-F2 DN 50-100 ASV balancing valves are used for dynamic hydronic balance
More informationSeated valves (PN 16) VRB 2 2-way valve, internal and external thread VRB 3 3-way valve, internal and external thread
Data sheet Seated valves (PN 16) VRB 2 2-way valve, internal and external thread VRB 3 3-way valve, internal and external thread Description Combinations with other actuators could be seen under Accessories.
More informationTemperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25)
Data sheet Temperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25) Description Controller closes on rising temperature. The controllers are: - Type-tested acc. to EN 14597
More informationSeated valves (PN 16) VRB 2 2-way valve, internal and external thread VRB 3 3-way valve, internal and external thread
Data sheet Seated valves (PN 16) VRB 2 2-way valve, internal and external thread VRB 3 3-way valve, internal and external thread Description VRB valves provide a quality, cost effective solution for most
More informationON/OFF zone valves AMZ 112, AMZ 113
Data sheet ON/OFF zone valves AMZ 112, AMZ 113 Description The ON/OFF zone valves type AMZ 112 and AMZ 113 are typical used in connection with: Domestic and commercial central heating applications Domestic
More informationCombined automatic balancing valve AB-PM valve DN 10-32, PN 16
Data sheet Combined automatic balancing valve AB-PM valve DN 10-32, PN 16 Description AB-PM is a combined automatic balancing valve. It features three function in compact valve body: 1. Differential pressure
More information3 & 4-Way Rotary Valves
Applications: 3-way Valve 4-way Valve The ESBE 3 and 4-Way rotary valves type F are designed for mixing or diverting applications on heating and cooling systems. The valves are capable of controlling and
More informationSteel butterfly valves SBFV (PN 16/25)
ata sheet Steel butterfly valves SBFV (PN 16/25) escription anfoss SBFV are high performance steel butterfly valves that together with anfoss JIP ball valves complete the family of shut off valves designed
More informationSeated valves (PN 16) VRG 2 2-way valve, external thread VRG 3 3-way valve, external thread
Data sheet Seated valves (PN 16) 2-way valve, external thread 3-way valve, external thread Description Features: Bubble tight design Snap mechanical connection together with MV(E) 335, MV(E) 435 Dedicated
More informationPre-Fabricated Flushing Bypass Assembly for Plant Applications Hero Plant DN15-150
Pre-Fabricated Flushing Bypass Assembly for Plant Applications Description Hero Plant is a pre-fabricated, flushing bypass arrangement for balance, control, isolation, and operation of plant devices. Flow
More informationSeated valve (PN 16 & PN 25) VFM 2 Two way valve, flange
Data sheet Seated valve (PN 16 & PN 25) VFM 2 Two way valve, flage Descriptio Features: Low seat leakage rate (< 0,03 % of k vs ) Rageability R= >100:1 by PN 16 >100:1 by PN 25 up till DN 125 otherwise
More informationYour Personal Catalog Temperature Controllers All our know-how - is now yours
MAKING MODERN LIVING POSSIBLE Your Personal Catalog Temperature Controllers All our know-how - is now yours Index 3 RAVI 12 RAVK 20 RAVV 28 AFT 06/26/17/27 33 AVTB 41 AVTQ DN15 49 AVTQ DN20 57 FJV 61 STFW/VFG(S)
More informationChangeOver6 and NovoCon ChangeOver6 - Motorized 6-port Ball Valves
- Motorized 6-port Ball Valves Description NovoCon The and NovoCon are 6-port motorized ball valves that performs a diverting function between two water circuits in 4-pipe changeover system. This diverting
More informationAssisted lift operated 2/2-way solenoid valves Type EV251B
Data sheet Assisted lift operated 2/2-way solenoid valves Type EV251B EV251B with assisted lift is especially suitable for applications such as closed systems with low and fluctuating pressure conditions
More informationIntegrated Valve with Presetting for Manifolds in Two-Pipe Heating Systems
Data Sheet Integrated Valve with Presetting for Manifolds in Two-Pipe Heating Systems The integrated valve is designed for manifold applications in combination with a system connection piece. Valve and
More informationTechnote. Frese YDF-2F & YDF-20F - differential pressure control valve. Application. Benefits. Features.
Page 1 of 5 Application Frese YDF-2F and YDF-20F differential pressure control valves are used in central heating-, ventilation-, and district heating systems This model is a high-performing adjustable
More informationPressure independent balancing and control valve For ON/OFF control
KT 512 Pressure independent balancing and control valve For ON/OFF control Pressurisation & Water Quality Balancing & Control Thermostatic Control ENGINEERING ADVANTAGE High-performing and compact, these
More informationSeries 240 Electric Control Valve Type 3241/3274 Globe Valve Type 3241 Electric Control Valve Type 3244/3274 Three-way Valve Type 3244
Series 240 Electric Control Valve Type 3241/3274 Globe Valve Type 3241 Electric Control Valve Type 3244/3274 Three-way Valve Type 3244 Application Versatile control valves with globe or three-way valve
More information2, 3 and 4 - way valves VZL
2, 3 and 4 - way valves VZL Description VZL 2 VZL 3 VZL 4 VZL valves provide a high quality, cost effective solution for the control of hot and/or chilled water for fan coil units, small reheaters, and
More informationZONE CONTROLE / 2-WAY
ZONE CONTROLE / 2-WAY PRESSURE INDEPENDENT BALANCING AND CONTROL VALVE ON/OFF High-performing and compact, these pressure-independent temperature control valves for variable flow heating and cooling systems,
More informationIntegrated Presetting Valves for Normal (013G0380) and Small (013G0381) Volume Flows
Integrated Presetting Valves for Normal (013G0380) and Small (013G0381) Volume Flows Application Integrated valves, type RA-N (013G0380) and RA- U (013G0381), with built-in presetting are designed for
More informationTypetested versions With Type 3213 Globe Valve, unbalanced. With Type 3214 Globe Valve, balanced
Electric Control Valves/Controller with Electric Actuator with safety function, typetested Types 3213/5725, 3214/5725 Single-seated Globe Valve Type 3213, unbalanced Single-seated Globe Valve Type 3214,
More informationIntegrated Presetting Valves - for Normal Volume Flows RA-N and for Small Volume Flows RA-U
Integrated Presetting Valves - for Normal Volume Flows RA-N and for Small Volume Flows Application RA-N 013G7382 013G7387 Integrated valves, type RA-N 013G7382 and 013G7387, with built-in presetting are
More informationOperating Guide SBFV (PN16/25) ENGLISH Steel butterfly valve SBFV Page 2. Danfoss VI.IX.A1.02 1
Operating Guide SBFV (PN16/25) ENGLISH Steel butterfly valve SBFV www.danfoss.com Page 2 Danfoss 2016.06 VI.IX.A1.02 1 Table of Contents: 1. OVERVIEW... 3 2. GENERAL... 3 2.1 Safety...3 2.2 Proper use...4
More informationPressure Independent Control Valve AB QM, ½ thru 2 2½ thru 4 5 thru 10 Valve Size
Features and Benefits Danfoss 2016.04 The AB QM temperature control valve provides pressure independent regulation of flow while also providing flow limiting system balance. The valve internally contains
More informationStatic Balancing Valve
Static Balancing Valve Series W-JP45X-16Q Sizes: DN50-DN300 APPLICATION The Series W-JP45X Static Balancing Valve is designed for flow balancing in cooling, heating or process water systems. Its measuring
More informationSelf-operated Pressure Regulators Type Universal Excess Pressure Valve
Self-operated Pressure Regulators Type 41-73 Universal Excess Pressure Valve Application Pressure regulators for set points from 0.05 to 8 bar Valve nominal sizes DN 15 to 100 Nominal pressure PN 16 to
More informationDA 50. Differential pressure controllers Adjustable set-point
DA 50 Differential pressure controllers Adjustable set-point IMI TA / Differential pressure controllers / DA 50 DA 50 These differential pressure controllers for heating and cooling systems are particularly
More informationSTEVI 450 / way control valve in mixing and diverting design DN
STEVI 450 / 451 with electric and pneumatic actuators 3-way control valve in mixing and diverting design DN 15-150 STEVI 450 / 451 Electric actuator ARI-PREMIO Enclosure IP 65 2 torque switches 1 travel
More informationPressure independent balancing and control valve AB-QM DN
Pressure independent balancing and control valve AB-QM DN 10-150 AB-QM valve equipped with an actuator is a control valve with full authority and automatic balancing function - flow limiter. Typical applications
More informationPressure independent balancing and control valve
Pressure independent balancing and control valve AB-QM DN 10-150 AB-QM valve equipped with an actuator is a control valve with full authority and automatic balancing function - flow limiter. Typical applications
More informationSelf-operated Pressure Regulators Type Universal Pressure Reducing Valve
Self-operated Pressure Regulators Type 41-23 Universal Pressure Reducing Valve ANSI version Application Pressure regulators for set points from 0.75 to 400 psi (0.05 to 28 bar) Valves in NPS ½ to 4 (DN
More informationManual presetting valves LENO MSV-BD
Manual presetting valves LENO MSV-BD Description LENO MSV-BD is a range of manual valves for balancing flow in heating, cooling and domestic hot water systems. LENO MSV-BD is a combined presetting and
More informationFloor heating system, heating circuit with FHV-A in flow.
Application FHV control valves are ideally suited for controlling the temperature of individual under-floor heated rooms and for systems using floor-heating in conjunction with radiators. Danfoss offers
More informationTechnische Dokumentation Technical Documentation
Technische Dokumentation Technical Documentation Fully Lined Sampling Valves XOMOX International GmbH & Co. OHG Dok. Nr.: tdb_sample_gb Von-Behring-Straße 15 D-88131 Lindau / Deutschland Januar 2008 Fully
More informationTechnische Dokumentation Technical Documentation
Technische Dokumentation Technical Documentation XOMOX Resilient Seated Butterfly Valves Series 7500 XOMOX International GmbH & Co. OHG Dok. Nr.: tdb_7500_gb Von-Behring-Straße 15 D-88131 Lindau / Deutschland
More informationValve bodies type RA-N with integrated presetting
Data Sheet Application Straight version Angle version Left mounted angle version Horizontal angle version All RA-N valve bodies can be used together with all types of thermostatic elements in the RA 2000
More informationPremounted Midi Shunts
Application Midi Shunt 088U0181 - with one circuit Midi Shunt 088U0182 - with two circuits Midi Shunt 088U0183 - with three circuits The Danfoss floor heating midi shunt is a series of pre-mounted shunts
More informationHigh Capacity Valve Body, Type RA-G
Data Sheet The RA-G valves are fitted with a grey protective cap. This protective cap must not be used as a manual shut off device. A special manual shut off device is available (code no. 013G3300). Application
More informationMaintenance-free metallic seat shut-off globe valves
Type leaflet 7150.1-10 BOA-H R Maintenance-free metallic seat shut-off globe valves with bellows flanged to new European standard 1092-2 type 21 Grey cast iron PN 16 DN 15-300 Nodular cast iron PN 16 DN
More informationGlobe Valve, Metal. Sectional drawing
Globe Valve, Metal Construction The GEMÜ pneumatically operated 2/2-way globe valve has a low maintenance membrane actuator which can be controlled by inert gaseous media. The valve plug is fixed to the
More informationSTAF, STAF-SG. Balancing valves PN 16 and PN 25 DN
STAF, STAF-SG Balancing valves PN 16 and PN 25 DN 20-400 IMI TA / Balancing valves / STAF, STAF-SG STAF, STAF-SG A flanged, cast iron (STAF) and ductile iron (STAF-SG) balancing valve that delivers accurate
More informationControl valves with pneumatic actuators up to 350 C PN
300 540 1080 2 Features Suitable in building and process engineering for various mediums 0...+200 C Suitable with stuffing box extension or stem seal with stainless steel bellow to 10...+350 C and for
More informationMaintenance-free metallic seat shut-off globe valves
Type leaflet 7150.1/5-10 BOA R -H Maintenance-free metallic seat shut-off globe valves with bellows flanged to new European standard 1092-2 type 21 Grey cast iron PN 16 DN 15-300 Nodular cast iron PN 16
More informationPressure independent balancing and control valve
Pressure independent balancing and control valves KTM 512 Pressure independent balancing and control valve Pressurisation & Water Quality Balancing & Control Thermostatic Control ENGINEERING ADVANTAGE
More informationSTAF-SG. ANSI flanges. Balancing valves DN
STAF-SG ANSI flanges Balancing valves DN 20-400 IMI TA / Balancing valves / STAF-SG ANSI flanges STAF-SG ANSI flanges A flanged, ductile iron balancing valve that delivers accurate hydronic performance
More informationARI-STEVI 450 / 451 (DN15-150) Control valve - 3-way-form (mixing/diverting valve) (optional with screwed seat ring)
With pneumatic and electric actuators ARI-STEVI 450 / 451 (DN15-150) Control valve - 3-way-form (mixing/diverting valve) (optional with screwed seat ring) ARI-STEVI 450 / 451 Pneumatic actuator ARI-DP
More informationARI-STEVI 450 / 451 Pneumatic actuator ARI-DP 32-34T. Electric actuator ARI-PREMIO 2,2-25 kn ARI-PREMIO-Plus 2G 2,2-25 kn
ARI-STEVI 450 / 451 (DN15-150) Control valve - 3-way-form (mixing/diverting valve) (optional with screwed seat ring) With pneumatic and electric actuators ARI-STEVI 450 / 451 Pneumatic actuator ARI-DP
More information3-way control valve in mixing and diverting design
with electric and pneumatic actuators 3-way control valve in mixing and diverting design 1/2-6 STEVI 450 / 451 Electric actuator Enclosure IP 65 2 torque switches 1 travel switch Handwheel Additional devices
More informationControl shut-off butterfly valves DN 25 DN 200 PN
Control shut-off butterfly valves DN 25 DN 200 4.1.1. Features HVAC, sanitary and raw water plants as shut-off element for water -10...+110 C Leakage rate: tight sealing Control and shutt-off butterfly
More informationSonoSensor 30 Ultrasonic flow sensor
Data Sheet SonoSensor 30 Ultrasonic flow sensor Description MID examination certificate no.: LT-1621- MI004-030 SonoSensor 30 is an ultrasonic flow sensor especially designed for heating, cooling or combined
More informationSelf-operated Pressure Regulators Type Universal Excess Pressure Valve
Self-operated Pressure Regulators Type 41-73 Universal Excess Pressure Valve ANSI version Application Pressure regulator for set points from 0.75 to 400 psi (0.05 to 28 bar) Valves in NPS ½ to 4 (DN 15
More informationPressure reducing valve Pressure reducing valve in straightway form DN
Pressure reducing valve Pressure reducing valve in straightway form DN 15-150 ARI-PREDU Pressure regulating valve, straight through with diaphragm actuator DMA Actuator with rolling diaphragm Grey cast
More informationSTAF-SG. ANSI flanges. Balancing valves Size 3/4-16
STAF-SG ANSI flanges Balancing valves Size 3/4-16 IMI TA / Balancing valves / STAF-SG ANSI flanges STAF-SG ANSI flanges A flanged, ductile iron balancing valve that delivers accurate hydronic performance
More informationThermostatic actuator RAVI - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)
- for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) Description RAVI is self-acting thermostatic actuator primarily for use for temperature control of small hot water cylinders - either storage
More informationControl Valve 23 / 24 Single-seat straight-way valve with exchangeable seat ring
Change from one to two columns Data Sheet 10/138.29EN Rev. B Control Valve 23 / 24 Singleseat straightway valve with exchangeable seat ring Size DN 15... DN 100 With pneumatic actuator Verschiedene Gehäusewerkstoffe
More informationDiaphragm Valve, Metal
Diaphragm Valve, Metal Construction The 601, and manually operated diaphragm valves have a temperature resistant plastic handwheel, 602 has a stainless steel handwheel. Bonnet and internals are made all
More informationTECHNICAL DATASHEET FLOWSEAL MS - Triple Offset Valves DIN/Metric
brands you trust. TECHNICAL DATASHEET FLOWSEAL MS - Triple Offset Valves DIN/Metric Index and Model Numbers for Gears with Hand Wheels Model Numbers for Gears with Hand Wheels...2 Figure Number System...3
More informationARI-STEVI 423 / 463 Pneumatic actuator ARI-DP 34-34T. Electric actuator ARI-PREMIO 5-25 kn ARI-PREMIO-Plus 2G 5-25 kn
Control valve - 3-way-form (mixing/diverting valve) (optional with screwed seat ring) With pneumatic and electric actuators ARI-STEVI 423 / 463 Pneumatic actuator ARI-DP 34-34T Reversible pneumatic actuator
More informationARI-STEVI 423 / 463 Pneumatic actuator ARI-DP 34-34T. Electric actuator ARI-PREMIO 5-25 kn ARI-PREMIO-Plus 2G 5-25 kn
ARI-STEVI 423 / 463 (DN200-300) Control valve - 3-way-form (mixing/diverting valve) (optional with screwed seat ring) With pneumatic and electric actuators ARI-STEVI 423 / 463 Pneumatic actuator ARI-DP
More informationARI-STEVI 450 / 451 (DN15-150) Control valve - 3-way-form (mixing/diverting valve) (optional with screwed seat ring)
With pneumatic and electric actuators Control valve - 3-way-form (mixing/diverting valve) (optional with screwed seat ring) ARI-STEVI 450 / 451 Pneumatic actuator ARI-DP 32-34T Reversible pneumatic actuator
More informationBall Valves JIP (PN 16, 25, 40)
Ball Valves JIP (PN 16, 25, 40) Description Danfoss JIP ball valves are shut off valves developed for District Heating and District Cooling networks, with circulating medium. It is a range of steel ball
More informationData sheet: Wilo-Yonos MAXO 40/0,5-16
Data sheet: /,5- Pump curves v 5 5 5 6 P /W n= const 5 5 /,5- ~ V - DN /,5- ~ V - DN 6 m/s Approved fluids (other fluids on request) Heating water (in accordance with VDI 5) Water-glycol mixtures (max.
More informationSeries 240 Pneumatic Control Valves Type and Type Three-way Valve Type 3244
Series 240 Pneumatic Control Valves Type 3244-1 and Type 3244-7 Three-way Valve Type 3244 DIN and ANSI versions Applications Mixing or flow-diverting valves for use in process engineering and industrial
More information