Operating Guide SBFV (PN16/25) ENGLISH Steel butterfly valve SBFV Page 2. Danfoss VI.IX.A1.02 1

Size: px
Start display at page:

Download "Operating Guide SBFV (PN16/25) ENGLISH Steel butterfly valve SBFV Page 2. Danfoss VI.IX.A1.02 1"

Transcription

1 Operating Guide SBFV (PN16/25) ENGLISH Steel butterfly valve SBFV Page 2 Danfoss VI.IX.A1.02 1

2 Table of Contents: 1. OVERVIEW GENERAL Safety Proper use TRANSPORTATION AND STORAGE Transportation Receiving Storage INSTALLATION IN THE PIPELINE General installation instructions Site requirements Place of installation Installation of the valve with welded ends Installation into horizontal pipeline Installation into vertical pipeline Welding procedures Installation of the valve with flanged connections PUTTING THE VALVE INTO OPERATION Visual inspection Function check and pressure test Start-up MAINTENANCE AND SERVICING General safety instructions Inspection intervals Maintenance and replacement of parts Manual gear removal and installation Other actuators Tightening the valve shaft seal Shut-off seal replacement TROUBLESHOOTING STANDARD MATERIALS. REFER TO APPENDIX Danfoss VI.IX.A1.02

3 1. Overview Read the entire instructions carefully before commencing the valve installation and start-up work. Keep the instructions in the proximity of the valve for the easy access by the valve operators. The warranty only covers manufacturing and material faults. Danfoss takes no responsibility for any damage caused by improper installation, maintenance or storage. 2. General Danfoss butterfly valves type SBFV, are shut off and control valves developed for District Heating and District Cooling networks. Danfoss Butterfly Valves type SBFV can be used for the following media: - water - hot water - glycolic water up to 50% If the valve is to be operated under deviating operating conditions and in other fields of application, the manufacturer should be consulted. 2.1 Safety These operating and maintenance instructions have to be observed at all times. It is not allowed for the user to modify the product or the mounting parts/fittings supplied with it. Danfoss does not assume any warranty or liability for consequential damage arising from the non-compliance with these instructions. Before removing safety devices and/or carrying out work on the valve, the pipe section should be pressureless, leaving no risk. Unauthorized, unintentional and unexpected operation as well as dangerous movement caused by stored energy (compressed air, pressurized fluids) should be avoided. Before dismantling the valve, the pipeline should be completely emptied. Installation, maintenance and other activities performed on the valve should be done only by qualified and specially trained personnel. For further specifications and information such as dimensions, materials and fields of applications, please refer to the related documentations (SBFV Data Sheet) VI.IX.A1.02 Danfoss

4 2.2 Proper use Danfoss SBFV Butterfly Valves are designed for installation in the pipelines. The technical application limits (e.g. working pressure, medium, temperature etc.) are described in the product-related documentation (SBFV Data Sheet). The standard model can be used to allow the flow of the medium in one direction in pressurized pipelines and to prevent the back-flow. Danfoss SBFV butterfly valve should be used in media in which there is no risk of clogging. To keep a good sealing and avoid damage of seal, fluid should not contain hard solid particulates. For any deviating operating conditions and applications the user should obtain the manufacturer s prior written approval. 4 Danfoss VI.IX.A1.02

5 3. Transportation and storage 3.1 Transportation During transportation, the valve should be stable and protected with special packaging (e.g. container, special pallets) and should have its disk slightly opened (10 ). The packaging also needs to ensure that the valve is protected against weather influences and damage. When the valve is transported long distance (e.g. overseas) and exposed to special climatic conditions, it needs to be protected by sealing it in plastic wrapping and adding a desiccant. 3.2 Receiving During the receiving inspection, check that the valve and its accessories are free from any transportation-induced damage. 3.3 Storage During storage, the valve should be protected against sand, dust and any other impurities. Avoid long-term storage of the valve outdoors exposed to the effects of rain, sunlight or frost. When hoisting the valve, always use lifting straps threaded through the lifting lugs and around the valve s upper neck (see picture 1: method A and B). Hoisting the valve with the lifting straps threaded around the actuator is forbidden (see picture 1: method C). Use special caution when hoisting, transporting and installing the valve. The actuator s centre of gravity may deviate from the valve centre line. This may tilt the valve and actuator during lifting. Even minor impacts may damage the actuator or change the actuator s or valve s adjustments. Method A Method B Method C Picture 1: Methods of lifting the valve Take the weight of the valve into account when handling it. VI.IX.A1.02 Danfoss

6 4. Installation in the pipeline 4.1 General installation instructions Incorrect installation may result in serious personal injury as well as malfunction of the equipment. These instructions should therefore be followed carefully when installing the valve. These instructions do not cover all possible operating scenarios. For any specific operating condition guidance, please contact the manufacturer Site requirements The installation of the valve in the pipeline should be a stress-free as possible. When work is done in the valve area which may cause dirt (e.g. painting, erection of brick walls or concrete work) the valve should be protected by a suitable cover. Before the valve is installed, it should be checked for any transport or storage damage. While being stored on the construction site before its installation, the valve should be protected against dirt by an appropriate cover. When the valve is installed it should be free of dirt and dust. Danfoss does not assume any liability for consequential damage caused by dirt, grit etc. Clean the pipework carefully before installing the valve. Any welding debris and other impurities remaining inside the pipework may damage the valve s shut-off surfaces at a later stage. In this connection, it is also advisable to check that the valve is free from any impurities induced by transportation and storage Place of installation The requirements for the place of installation are: - to ensure there is enough space to allow function checks. - to ensure there is enough space to allow maintenance work (e.g. dismantling and cleaning of the valve). In case of open-air installation, the valve should be protected against extreme weather conditions by covering it properly. 6 Danfoss VI.IX.A1.02

7 4.2 Installation of the valve with welded ends Installation into horizontal pipeline The most recommendable installation position for a butterfly valve is in a horizontal position and into horizontal pipeline (see picture 2). The butterfly valve can alternately be installed at an angle of maximal Installation into vertical pipeline Picture 2: Horizontal installation position If the valve is welded to a vertical pipeline (see picture 3), close the valve and cover the seal and disc with a water cushion of at least 40 mm. The water protects from welding spatters that may damage the seal and disc surfaces during welding. Picture 3: Vertical installation position VI.IX.A1.02 Danfoss

8 4.2.3 Welding procedures - The butterfly valve should be welded only by an authorized welder. - The butterfly valve should remain closed during installation and welding to ensure that welding residue does not damage the seal surfaces. - The ends of the pipes should be parallel to the valve and correctly aligned. - The valve should be as long as the distance between pipe ends, taking into consideration the welding gaps. - The inner diameter of the pipes should be the same as the inner diameter of the ends of the butterfly valve. - The main flow direction should be the same as the recommended flow direction of the valve. During welding the ground should be connected to the pipeline. It is not allowed to connect the ground to the valve neck, actuator flange or actuator. 4.3 Installation of the valve with flanged connections When the valve is installed between pipeline flanges, the flanges should be plane-parallel and in true alignment. Misaligned pipelines should be put into a true alignment position before the valve is installed. Otherwise the body may be exposed to impermissibly high loads and strain during operation which may even cause the body to break. The butterfly valve should be installed only by authorized personnel. The valve should remain closed during installation to ensure that any residue or dirt doesn t damage the sealing faces. The valve should be as long as the distance between the flanges in the pipeline, taking into consideration the gasket. The flanges in the pipeline should be compatible with valve flanges. The bolts and nuts used for installation should be selected to match operating conditions. Bolts and nuts should also fulfill requirements of the pressure, temperature, flange material and gasket. For detailed information please refer to standards EN , EN and EN The gasket used on installation should be selected to match operating conditions, temperature, pressure and medium. Gasket dimensions should be compatible with sealing faces of the flanges. For detailed information please refer to the standard EN The main flow direction should be the same as the recommended flow direction of the valve. The recommended installation position for the butterfly valve is at an angle or with the shafts in the horizontal position. 8 Danfoss VI.IX.A1.02

9 Between the butterfly valve and an inspection valve, an elbow, T-pieces and Y-filters should be provided minimal distance of 3xDN. Otherwise irregular flow may disturb the proper function of the valve. When installing a butterfly valve downstream of a control valve or a plunger valve, make sure that there is enough space between them (min. 10xDN). For alternative installation position, please contact and consult with the manufacturer. VI.IX.A1.02 Danfoss

10 5. Putting the valve into operation 5.1 Visual inspection Visual inspection of the valve and its equipment, especially all functional parts, should be conducted prior to putting the valve into operation. All screwed connections need to be checked as to whether they are tightly fastened. 5.2 Function check and pressure test Before the installation of the valve, its function parts (disk) should be completely opened and closed at least once and their proper running should be tested. When closed, the butterfly valve should only be exposed to pressures not exceeding its nominal pressure. Pressure tests during which the pipeline is filled in flow (opening) direction are unproblematic. 5.3 Start-up Flush the pipework thoroughly once the valve installation has been completed. All valves delivered to customer passed the hydro test at the factory; however it is necessary to check that there are no faults due to transportation and handling. Make sure that the valve-actuator combination functions without problems prior to the start-up procedure. Always close the valve using the actuators mechanical travel stops; stay below the maximum torque limit. Avoid the use of excessive force in closing as this cannot improve that valve s tightness. A valve provided with an electric actuator should always be opened electrically, with the travel limit serving as the closing limit. In an emergency, you may open and close the valve by turning the electric actuator hand wheel. In these cases, however, observe that the hand wheel s closing limit has been set to turn the valve disc 2-3 hand wheel revolutions beyond the optimal closed positions. This means that the optimal tightness is achieved by turning the hand wheel 2-3 revolutions in the opening direction, starting from the gear s mechanical closing limit. 10 Danfoss VI.IX.A1.02

11 6. Maintenance and servicing 6.1 General safety instructions Prior to any inspection and maintenance work to be performed on the valve or mounted parts and attachments, the pressurized pipeline should be shut off, the pressure should be relieved and the system should be secured against unintentional switching on. Depending on the kind and criticality of the medium or fluid conveyed, all the required safety regulations must complied with! Upon completion of the maintenance work and prior to resuming operation, all connections should be checked for proper fastening and leak-freeness. 6.2 Inspection intervals The leak-freeness, smooth operation and corrosion protection of the valve should be checked at least once per year. Under extreme operating conditions, inspection needs to be done at shorter intervals. The body seals can be replaced, if required, depending on the type of fluid conveyed. 6.3 Maintenance and replacement of parts Danfoss valves are durable and dependable. An appropriately selected and carefully installed valve will not require maintenance during its life cycle. Leakage from the valve s shut-off surfaces is often caused by wear and tear, pipework impurities or damage resulting from pressure impacts. Impurities can be removed by opening the valve and allowing the flow to flush the shut-off surfaces clean. Probability of hydro-stress can be excluded by using by-pass valves. The scope of maintenance and repair work consists of: - Cleaning of internal surfaces. - Replacement of main gasket. - Tightening or replacement of shaft sealing. If the pipeline is not under pressure, this work can be performed online. For the rest of the repair works, the valve should be taken away from the line. VI.IX.A1.02 Danfoss

12 6.4 Manual gear removal and installation Avoid removing the actuator from the valve. Actuator has been calibrated at the factory and if removed, the actuator may have to be re-calibrated. Removal of manual gear: - Close the valve fully with the handwheel. - Mark the manual gear in relation to the valve - Turn out bolts between actuator and valve - Take out actuator - Remove parallel key Installation of manual gear: - Make sure that the valve is in closed position. - Place parallel keys. - Install manual gear in original position. Attach the manual gear to the valve. 6.5 Other actuators For detailed instructions concerning actuator removal, installation and adjustment, contact the valve s supplier or manufacturer. 6.6 Tightening the valve shaft seal Tightening the valve shaft seal is included in regular maintenance. Avoid excessive tightening. The sufficient tightness level is reached when the leakage stops. The tensions screws are indicated by number 17 in the exploded view attached. Prior to commencing the replacement procedure, check that the pipework is pressure-free. The components referred to in the disassembly and installation instructions are set out in the exploded view contained in Appendix. 12 Danfoss VI.IX.A1.02

13 Disassembling: - Remove the actuator as instructed above. (Section 6.4). - Remove parallel key (12). - Remove screws that are holding the gland (15). - Remove gland (9). - Remove O rings (18) with sealing bush (8). - Remove gland packing (6). Installation: - Carefully clean all surfaces. Prior to commencing the installation work, check that there are no sharp edges on the valve shaft that could damage the O-rings and sealing. - Place gland packing (6). - Place O rings (18) with sealing bush (8). - Place gland (9). - Tighten the screws that are holding the gland (16). - Place parallel key (12). - Install actuator as instructed in Section Shut-off seal replacement Prior to a shut-off seal replacement, remove the valve from the pipework. It is not necessary to remove actuator for a shut-off seal replacement. Turn the valve disc to the closed position. The components referred to in the disassembly and installation instructions are set out in the exploded view contained in Appendix. Disassembling of the lamellar seal: - Open the disk until the profile seal emerges from the body - Unfasten the retaining ring screws(17) - Remove retaining ring (3) and lamellar seal(4) Installation: - Prior to installation of the new parts, carefully clean all surfaces of frame, disk and retaining ring. Check the condition of sealing surfaces prior to starting the installation work. - Keep the valve disk in closed position during the shut-off replacement procedure. - Place lamellar seal (4). - Install the retaining ring (3). - Tighten all screws (17) evenly in a crosswise sequence. VI.IX.A1.02 Danfoss

14 7. Troubleshooting For all maintenance and repair work please observe the general safety instructions under Section 6.1! Problem Cause Remedial action Valve makes noise Unfavorable installation position causing unfavorable flow around or inside the valve (e.g. installed too closely downstream of an elbow etc.) Change installation position Leakage losses Leakage on the shaft Leakage on the sealing Operational torque too high Valve blocked Cavitation in the valve High operating forces Remains and dirt on body sealing surfaces Sealing on the shaft is blocked or dirty Damaged O ring in the sealing bush Dirt between body seat and lamellar ring Gear stem is not lubricated A foreign matter is jammed in sealing area Valve operating beyond its design limits Operational data changed Seat of the valve polluted by deposits Valve is dry in the pipeline, no medium present If dirt is crusted, clean sealing surfaces and sealing ring Replace sealing on the shaft Replace O ring in the sealing bush Clean body seat and lamellar ring Lubricate the gear stem Use the valve in OPEN POSITION so that the foreign matter is flushed away If that doesn t help, dismantle the valve and remove foreign matter Butterfly valve not suitable for use as control valve. Replace the valve with more suitable valve type Flush valve, dismantle, if necessary and clean seat area Valve can be operated more easily when wet 14 Danfoss VI.IX.A1.02

15 8. Standard materials. Refer to Appendix. Part Material 1 Body Carbon steel EN P265GH 2 Disk Carbon steel EN P265GH 3 Retaining ring Stainless steel X5CrNi Lamellar seal X6CrNiMoTi Graphite 5 Drive Shaft Stainless steel X17CrNi Gland packing Graphite / PTFE 7 Ring Stainless steel X5CrNi Sealing bush GGG CrNi Gland Carbon steel EN P265GH,EN S355J2+N 10 Cover Carbon steel EN P265GH 11 Pin Stainless steel X17CrNi Parallel key Carbon steel C45E 13 Radial bearing INA PERMAGLIDE (SS+PTFE) 14 Axial bearing INA PERMAGLIDE (SS+PTFE) 15 Connections Stainless steel A Connections Stainless steel A Screw Stainless steel A O ring EPDM HT / VITON APPENDIX: Parts list and standard materials VI.IX.A1.02 Danfoss

16 Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary eady agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved. 16 Danfoss DHS-SRMT/SI VI.IX.A1.02

Danfoss Butterfly Valve

Danfoss Butterfly Valve Triple Eccentric Danfoss Butterfly Valve Operating, installation and maintenance instructions Edition 1 / January 2015. Table of Contents: 1 Overview... - 1-2 General... - 1-2.1 Safety notes... - 1-2.2

More information

BUTTERFLY VALVE WITH WELDED ENDS INSTALLATION AND MAINTENANCE MANUAL

BUTTERFLY VALVE WITH WELDED ENDS INSTALLATION AND MAINTENANCE MANUAL BUTTERFLY VALVE 31300 SERIES INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE 1. Overview Read these instructions carefully before starting the valve installation and start-up work. Safe keep the instructions

More information

Operating and maintenance instructions VAG RETO-STOP Non-Return Valve

Operating and maintenance instructions VAG RETO-STOP Non-Return Valve Operating and maintenance instructions VAG RETO-STOP Non-Return Valve KAT 1544-B Edition2 02-09 Content 1.General 1.1 Safety 1.2 Proper use 2.Transport and storage 2.1 Transport 2.2 Storage, packaging

More information

VAG RIKO Plunger Valve

VAG RIKO Plunger Valve Operating and maintenance instructions VAG RIKO Plunger Valve KAT-B 2010 Edition 7-1 / 03-11 Content 1 General 3 1.1 Safety 3 1.2 Proper use 3 1.3 Marking 3 We reserve the right to make technical changes

More information

Operating and maintenance instructions. VAG SKR Slanted Seat Tilting Disk Check Valve

Operating and maintenance instructions. VAG SKR Slanted Seat Tilting Disk Check Valve Operating and maintenance instructions VAG SKR Slanted Seat Tilting Disk Check Valve KAT-B 1510 Edition 4-12/2010 Content 1 General 3 1.1 Safety 3 1.2 Proper use 3 2 Transportation and storage 3 2.1 Transportation

More information

Steel butterfly valves SBFV (PN 16/25)

Steel butterfly valves SBFV (PN 16/25) ata sheet Steel butterfly valves SBFV (PN 16/25) escription anfoss SBFV are high performance steel butterfly valves that together with anfoss JIP ball valves complete the family of shut off valves designed

More information

back to main page Type: Butterfly valves Instructions and Operation Manual Warning! Warning! Danger for life! 1. Intended use Danger for life!

back to main page Type: Butterfly valves Instructions and Operation Manual Warning! Warning! Danger for life! 1. Intended use Danger for life! Instructions and operation manual for butterfly valves This manual is intended to support the users of Herberholz butterfly valves type HRD/HRA, RD/RA, LDKE/LDKF for installation, operation and maintenance

More information

Steel butterfly valves

Steel butterfly valves ata sheet Steel butterfly valves SBFV (PN 16/25) escription anfoss SBFV are high performance steel butterfly valves that together with anfoss JIP ball valves complete the family of shut off valves designed

More information

When installing the screwed end, socket weld & flanged end valves the following respective procedures shall be followed for better performance.

When installing the screwed end, socket weld & flanged end valves the following respective procedures shall be followed for better performance. 1. Storage LARSEN & TOUBRO LIMITED Page 1 of 5 1.1. All valves are to be stored in fully open position, in order to protect the sphere surface and soft valve seats. 1.2. Before shipping, the inlet and

More information

VAG CEREX 300 Butterfly Valve

VAG CEREX 300 Butterfly Valve Operation and Maintenance Instructions VAG CEREX 300 Butterfly Valve VAG CEREX 300-W Butterfly Valve VAG CEREX 300-L Butterfly Valve Edition 7-13-12-2017 Table of Contents 1 General 3 1.1 Safety 3 1.2

More information

Declaration of Conformity as per Directive 97/23/EC

Declaration of Conformity as per Directive 97/23/EC Declaration of Conformity as per Directive 97/23/EC The manufacturer declares that:, 47906 Kempen, Germany PTFE-lined Rotary plug valves Series 23e, with packing with lever for 90 operation with worm gear

More information

VAG CEREX M300 Butterfly Valve

VAG CEREX M300 Butterfly Valve Operation and Maintenance Instructions VAG CEREX M300 Butterfly Valve KAT 1310-B Edition4 12-17 Table of Contents 1 General 3 1.1 Safety 3 1.2 Proper use 3 1.3 Identification 3 VAG reserves the right to

More information

Operating and Maintenance Instructions. VAG LIMU-STOP Non-Return Valve

Operating and Maintenance Instructions. VAG LIMU-STOP Non-Return Valve Operating and Maintenance Instructions VAG LIMU-STOP Non-Return Valve KAT-B 1547 Edition 1-01/2018 Table of contents 1 General 3 1.1 Safety 3 1.2 Proper use 3 1.3 Identification 3 VAG reserves the right

More information

3-Way Ball Valve Type 23H

3-Way Ball Valve Type 23H Serial No. H-V062-E-4 contents 3-Way Ball Valve Type 23H User s Manual (1) Be sure to read following warranty clauses of our product 1 (2) General operating instructions 2 (3) General instruction for transportation,

More information

Installation and Operating Instructions. VAG AW Non-Return Valve

Installation and Operating Instructions. VAG AW Non-Return Valve Installation and Operating Instructions VAG AW Non-Return Valve KAT-B 2450 - Edition1-03-01-2018 Table of contents 1 General 3 1.1 Safety 3 1.2 Proper use 3 2 Transport and storage 3 2.1 Transport 3 2.2

More information

Installation, Operation And Maintenance Manual. Manual. For the 400 Series. ABZolute Seal. High Performance Butterfly Valve "Double Offset"

Installation, Operation And Maintenance Manual. Manual. For the 400 Series. ABZolute Seal. High Performance Butterfly Valve Double Offset Installation, Operation And Maintenance Manual Manual For the 400 Series ABZolute Seal High Performance Butterfly Valve "Double Offset" ABZ VALVE & CONTROLS CONTENT 1. INTRODUCTION 1.1 GENERAL NOTE 1.2

More information

Butterfly Valve Type 57P

Butterfly Valve Type 57P Butterfly Valve Type 57P Contents Lever Type: 50-200 mm (2-8 ) Body Material: CPVC Gear Type: 50-200mm (2-8 ) Body Material: CPVC (1) Be sure to read the following warranty clauses of our product 1 (2)

More information

Installation, Operation, and Maintenance Manual

Installation, Operation, and Maintenance Manual Industrial Process Installation, Operation, and Maintenance Manual Series PBFV Plastic Lined Butterfly Valve - Lug and Wafer Style Table of Contents Table of Contents Introduction and Safety...2 Safety

More information

GATE VALVES. Type P (Standard: Plug) Type S (Soft Seal) Contents. (1) Be sure to read the following warranty clauses of our product 1

GATE VALVES. Type P (Standard: Plug) Type S (Soft Seal) Contents. (1) Be sure to read the following warranty clauses of our product 1 Serial No. H-V011-E-12 GATE VALVES Type P (Standard: Plug) Type S (Soft Seal) Contents (1) Be sure to read the following warranty clauses of our product 1 User s Manual (2) General operating instructions

More information

series BUTTERFLY VALVE DOUBLE ECCENTRIC FLANGED FAF 3800 PRODUCTION STANDARDS DN100 DN2000 PN Design EN 593 EN ISO Flanged

series BUTTERFLY VALVE DOUBLE ECCENTRIC FLANGED FAF 3800 PRODUCTION STANDARDS DN100 DN2000 PN Design EN 593 EN ISO Flanged PRODUCTION STANDARDS DN100 DN2000 PN 10-16-25 Design EN 593 Connection End Connection EN 1092-2 ISO 7005-2 - Flanged EN 558 Series 14 DIN 3202 F4 Marking EN 19 Tests EN 12266-1 Corrosion Protection Electrostatic

More information

Storage, operating and maintenance instructions for AZ plug valves and Standard valves

Storage, operating and maintenance instructions for AZ plug valves and Standard valves ARMATUREN Plug - Valves metallic with PTFE Sleeve 2-7 way Storage, operating and maintenance instructions for AZ plug valves and Standard valves Plug - Valves FEP/PFA - lined, 2-3 way Butterfly - Valves

More information

T R A N S L A T I O N Declaration of Conformity as per Directive 2014/68/EU

T R A N S L A T I O N Declaration of Conformity as per Directive 2014/68/EU T R A N S L A T I O N Declaration of Conformity as per Directive 2014/68/EU The manufacturer declares that: Pfeiffer Chemie-Armaturenbau GmbH, 47906 Kempen, Germany Butterfly valves BR14a, BR14b, BR14b-Type

More information

Operating Instructions: Hand-operated, PTFE-lined butterfly valves, Series 22/23

Operating Instructions: Hand-operated, PTFE-lined butterfly valves, Series 22/23 0 Introduction These instructions are intended to assist users of BRAY PTFE-lined butterfly valves, Series 22/23 in fitting, operating and servicing valves. Risks may arise and the manufacturer's warranty

More information

Butterfly valve with electrical actuator VFY-WA

Butterfly valve with electrical actuator VFY-WA Butterfly valve with electrical actuator Description Position indicator Torque limiter Complete installation from factory - ready for installation Features: Spline driven one piece shaft connected to spherically

More information

Butterfly valve with electrical actuator VFY-WA

Butterfly valve with electrical actuator VFY-WA Butterfly valve with electrical actuator Description Position indicator Torque limiter Complete installation from factory - ready for installation Features: Spline driven one piece shaft connected to spherically

More information

Butterfly Valve Type 58 (PDCPD)

Butterfly Valve Type 58 (PDCPD) Serial No. H-V074-E Butterfly Valve Type 58 (PDCPD) 700mm (28 ) User s Manual Contents (1) Be sure to read the following warranty clauses of our product 1 (2) General operating instructions 2 (3) General

More information

Installation,Operation and Maintenance Manual H-V016-E-10. Serial No. 目次 ( ページ ) 1. Be sure to read the following warranty clauses of our product 1

Installation,Operation and Maintenance Manual H-V016-E-10. Serial No. 目次 ( ページ ) 1. Be sure to read the following warranty clauses of our product 1 Serial No. H-V016-E-10 Gauge Valve 目次 ( ページ ) 1. Be sure to read the following warranty clauses of our product 1 2. General operating instructions 2 User s Manual 3. General instructions for transportation,

More information

Mounting and Operating Instructions EB 5868/5869 EN

Mounting and Operating Instructions EB 5868/5869 EN Electric Control Valves Types 3213/5857, 3213/5824, Types 3214/5824, 3214/3374, 3214/3274 with safety function: Types 3213/5825, 3214/5825, 3214/3374, 3214/3274 Pneumatic Control Valves Types 3213/2780-1,

More information

Diaphragm Valves Type 15

Diaphragm Valves Type 15 Serial No. H-V031-E-8 Diaphragm Valves Type 15 User s Manual Contents (1) Be sure to read the following warranty clauses of our product 1 (2) General operating instructions 2 (3) General instructions for

More information

Mounting and Operating Instructions EB 8039 EN. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve

Mounting and Operating Instructions EB 8039 EN. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve Type 3351 Pneumatic On/off Valve Type 3351 Pneumatic On/off Valve Type 3351 Pneumatic On/off Valve Version with handwheel Mounting and Operating Instructions EB 8039 EN Edition May 2016 Definition of signal

More information

Installation, Operation, and Maintenance Manual

Installation, Operation, and Maintenance Manual Industrial Process Installation, Operation, and Maintenance Manual Cam-Tite Ball Valve Table of Contents Table of Contents Introduction and Safety...2 Safety message levels...2 User health and safety...2

More information

Pressure relief controller AVA (PN 25)

Pressure relief controller AVA (PN 25) Data sheet Pressure relief controller AVA (PN 25) Description AVA is a self-acting pressure relief controller primarily for use in district heating systems. The controller is normally closed and opens

More information

LNG Screw Down Non-Return Valve Installation, Operation and Maintenance Manual

LNG Screw Down Non-Return Valve Installation, Operation and Maintenance Manual Installation, Operation and Maintenance Manual Date of Issue: 04 August 2010 Page 1 of 27 QF 80: Issue 2 WARNING! BEFORE ANY INSTALLATION AND MAINTENANCE WORK CAN COMMENCE ENSURE THE VALVE AND SURROUNDING

More information

USER INSTRUCTIONS. Installation Operation Maintenance. NAF Setball SF Ball Sector Valves. Experience In Motion FCD NFENIM A4 09/16

USER INSTRUCTIONS. Installation Operation Maintenance. NAF Setball SF Ball Sector Valves. Experience In Motion FCD NFENIM A4 09/16 USER INSTRUCTIONS NAF Setball SF Ball Sector Valves FCD NFENIM4156-00 A4 09/16 Installation Operation Maintenance Experience In Motion Contents SAFETY 3 1 General 3 2 Lifting 4 3 Receiving Inspection 4

More information

Mounting and Operating Instructions EB 8135/8136 EN. Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil

Mounting and Operating Instructions EB 8135/8136 EN. Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil Type 3535 Three-way Valve with bellows seal and rod-type yoke (partial view) Mounting and Operating Instructions EB 8135/8136 EN Edition

More information

INSTALLATION, OPERATION, MAINTENANCE MANUAL FOR MANUALLY OPERATED STOP CHECK VALVE

INSTALLATION, OPERATION, MAINTENANCE MANUAL FOR MANUALLY OPERATED STOP CHECK VALVE INSTALLATION, OPERATION, MAINTENANCE MANUAL FOR MANUALLY OPERATED STOP CHECK VALVE Page 1 of 13 1.1 General CHAPTER 1 - GENERAL INFORMATION This manual contains maintenance instructions with pertinent

More information

VAG EKN Butterfly Valve

VAG EKN Butterfly Valve Operation and Maintenance Instructions VAG EKN Butterfly Valve KAT 1310-B Edition4 05-13 Table of Contents 1 General 3 1.1 Safety 3 1.2 Proper use 3 1.3 Identification 3 VAG reserves the right to make

More information

Standard Valves Series Globe Valves Series Angle Valves Series Way-Valves

Standard Valves Series Globe Valves Series Angle Valves Series Way-Valves Installation, Operation, Maintenance Instructions Standard Valves Series 035 000 Globe Valves Series 031 000 Angle Valves Series 033 000 3-Way-Valves 1 GENERAL INFORMATION These instructions are designed

More information

FRP Ball Valves INSTALLATION & MAINTENANCE MANUAL

FRP Ball Valves INSTALLATION & MAINTENANCE MANUAL FRP Ball Valves INSTALLATION & MAINTENANCE MANUAL FRP BALL VALVES TABLE OF CONTENTS MAINTENANCE AND INSTALLATION INSTRUCTIONS 1. 2. 2.1 2.2 2.3 2.4 GENERAL...Page 1 HANDLING...1 Receiving and Storing...1

More information

Keystone Figure V11 Butterfly Valve Installation, Operation and Maintenance Manual

Keystone Figure V11 Butterfly Valve Installation, Operation and Maintenance Manual Please read these instructions carefully - indicates that it may lead to injuries or damages on the properties. Warning - indicates that it may lead human body to serious injuries. Danger - indicates that

More information

USER INSTRUCTIONS. NAF Trunnball DL Ball Valves. Installation Operation Maintenance. Experience In Motion FCD NFENIM A4 01/15

USER INSTRUCTIONS. NAF Trunnball DL Ball Valves. Installation Operation Maintenance. Experience In Motion FCD NFENIM A4 01/15 USER INSTRUCTIONS NAF Trunnball DL Ball Valves FCD NFENIM4168-01-A4 01/15 Installation Operation Maintenance Experience In Motion Contents SAFETY 3 1 General 3 2 Lifting 4 3 Receiving Inspection 4 4 Installation

More information

5000/6000 SERIES BALL VALVES INSTALLATION - MAINTENANCE MANUAL

5000/6000 SERIES BALL VALVES INSTALLATION - MAINTENANCE MANUAL Date: August 2011 / Page 1 of 6 5000/6000 SERIES BALL VALVES INSTALLATION - MAINTENANCE MANUAL DESIGN The design features three piece construction and a free floating ball allowing ease of maintenance

More information

Installation, Operation and Maintenance Manual for the HE Series

Installation, Operation and Maintenance Manual for the HE Series Installation, Operation and Maintenance Manual for the HE Series High Performance Butterfly Valve "Double Offset" CONTENT IOM-HP-100614-1 1. INTRODUCTION 1.1 GENERAL NOTE 1.2 STRUCTURE & TYPE 1.3 OPERATION

More information

Flow controller (PN 25) AVQ - return and flow mounting

Flow controller (PN 25) AVQ - return and flow mounting Data sheet Flow controller (PN 5) - return and flow mounting Description is a self-acting flow controller primarily for use in district heating systems. The controller closes when set max. flow is exceeded.

More information

Diaphragm Valve Type 72

Diaphragm Valve Type 72 Serial No. H-V001-E-8 Diaphragm Valve Type 72 User s Manual Contents (1) Be sure to read the following warranty clauses of our product 1 (2) General operating instructions 2 (3) General instructions for

More information

Swing Check Valve ASAHI AV VALVES. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1

Swing Check Valve ASAHI AV VALVES. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1 Serial No. H-V013-E-13 Swing Check Valve User s Manual Contents (1) Be sure to read the following warranty clauses of our product 1 (2) General operating instructions 2 (3) General instructions for transportation,

More information

Installation and operating manual Quick closing valve (Bellow sealed) LK product no:

Installation and operating manual Quick closing valve (Bellow sealed) LK product no: LK product no: 902002 Article no: 74506 Revision: 2 Contents 1. General information... 3 2. Safety precautions... 3 2.1 Significance of symbols... 3 2.2 Explanatory notes on safety information... 3 3.

More information

Installation, Operation, and Maintenance Manual

Installation, Operation, and Maintenance Manual Industrial Process Installation, Operation, and Maintenance Manual Series PBV Plastic Lined Ball Valve Table of Contents Table of Contents Introduction and Safety...2 Safety message levels...2 User health

More information

Pressure relief controller AFA / VFG 2(1) (PN 16, 25, 40)

Pressure relief controller AFA / VFG 2(1) (PN 16, 25, 40) Data sheet Pressure relief controller AFA / VFG 2(1) (PN 16, 25, 40) Description The controller is a self-acting pressure relief controller primarily for use in district heating systems. The controller

More information

Instructions. for Installation, Operation and Maintenance of ABO Butterfly Valves, Series 600 and 900

Instructions. for Installation, Operation and Maintenance of ABO Butterfly Valves, Series 600 and 900 Instructions for Installation, Operation and Maintenance of ABO Butterfly Valves, Series 600 and 900 1. Instructions 2. Valve Description 3. Installation 4. Operation 5. Removal 6. Maintenance 7. Repairs

More information

Installation, Operation, and Maintenance Manual

Installation, Operation, and Maintenance Manual Intelligent Flow Measurement Your Sole Source for Badger Differential Producers Worldwide 6 Blackstone Valley Place, Lincoln RI 02865-1162 Ph: 401 334 1170 Fx: 401 334 1173 Em: solutions@wyattflow. Installation,

More information

Mounting and Operating Instructions EB 8111/8112 EN. Series V2001 Valves Type 3321 Globe Valve

Mounting and Operating Instructions EB 8111/8112 EN. Series V2001 Valves Type 3321 Globe Valve Series V2001 Valves Type 3321 Globe Valve Type 3321 Globe Valve with rod-type yoke and Type 3372 Electropneumatic Actuator (350 cm²) Mounting and Operating Instructions EB 8111/8112 EN Edition June 2013

More information

Contents H-V034-E-12. Serial No. (page) (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

Contents H-V034-E-12. Serial No. (page) (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2 Serial No. H-V034-E-12 Sediment strainer (Type Y) Contents (page) (1) Be sure to read the following warranty clauses of our product 1 User s Manual (2) General operating instructions 2 (3) General instructions

More information

Operating Instructions

Operating Instructions Operating Instructions ERHARD Tilting-Disc Check Valves with weight-loaded lever 1 Safety Aspects 2 Description of Product and Range of Application 3 Design Features Technical Data 4 Performance and Mode

More information

Operating and installation instructions

Operating and installation instructions Strainer PN6-160 1.0 General information on operating instructions...2-2 2.0 Notes on possible dangers...2-2 2.1 Significance of symbols... 2-2 2.2 Explanatory notes on safety information... 2-2 3.0 Storage

More information

Vexve Butterfly Valve User Manual p = PN 25 p = PN 20 (DN 1200)

Vexve Butterfly Valve User Manual p = PN 25 p = PN 20 (DN 1200) 30.03.2010 Vexve Butterfly Valve User Manual p = PN 25 p = PN 20 (DN 1200) Table of Contents 1. General 2. General Instructions and Cautions 3. Valve Markings 4. Valve Transportation and Storage 5. Installations

More information

Manufacturer s Declaration as per EU-Directives Page 1 of 2

Manufacturer s Declaration as per EU-Directives Page 1 of 2 The manufacturer Manufacturer s Declaration as per EU-Directives Page 1 of 2 BRAY Armaturen & Antriebe Europa, D47807 Krefeld for Butterfly valves all Series 2[.].& Series 3[.] : Series 20/21 (2 body-halves

More information

Pressure independent control valve with integrated flow limiter AVQM (PN 16) - return and flow mounting

Pressure independent control valve with integrated flow limiter AVQM (PN 16) - return and flow mounting Data sheet Pressure independent control valve with integrated flow limiter AVQM (PN 16) - return and flow mounting Description Controllers are used together with Danfoss electrical actuators: AMV 0 1)

More information

Butterfly Valves ASAHI AV VALVES

Butterfly Valves ASAHI AV VALVES Serial No. H-V030-E-8 Butterfly Valves Type 56: 400mm (16 ) Body: PP, PVDF Type 75: 450-600mm (18-24 ) Body: PP, PVDF Type 56D: 400mm (16 ) Body: PDCPD Type 75D: 450-600 mm (18-24 ) Body: PDCPD Contents

More information

FIVC. Static Balancing Valve. Technical data. Dimensions

FIVC. Static Balancing Valve. Technical data. Dimensions FIVC Static Balancing Valve Grey Cast Iron PN 16 Technical data Main features and materials High tightness (leakproofness class - A according to EN - 12266-1) Compact settlement Environment-friendly Tests

More information

KEYSTONE SERIES 320 BUTTERFLY VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

KEYSTONE SERIES 320 BUTTERFLY VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS Before installation these instructions must be fully read and understood HAZARD POTENTIALS disregarding of instructions improper use of product insufficiently qualified personnel Valve application to be

More information

Pressure reduction controllers (PN 25) AVDS - for steam AVD - for water

Pressure reduction controllers (PN 25) AVDS - for steam AVD - for water Data sheet Pressure reduction controllers (PN 25) - for steam AVD - for water Description Main data AVD: DN 15-50 k VS 0,4-25 m 3 /h PN 25 Setting range: 1-5 bar / 3-12 bar Temperature: - Circulation water/glycolic

More information

NAF-Torex butterfly valves Maintenance and installation instructions List of spare parts

NAF-Torex butterfly valves Maintenance and installation instructions List of spare parts NAF-Torex butterfly valves Maintenance and installation instructions List of spare parts Fi 41.42(4)GB 08.01 Contents SAFETY General 1 Lifting 2 Receiving inspection 3 Installation 4 Flange gaskets 5 Starting

More information

MERIDIAN, 2 or 3 PIECE, TRUNNION MOUNTED BALL VALVES

MERIDIAN, 2 or 3 PIECE, TRUNNION MOUNTED BALL VALVES INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS MERIDIAN, 2 or 3 PIECE, TRUNNION MOUNTED BALL VALVES Size Range 2 48 ASME Classes 150-2500 *It is recommended that the valve installer is familiar with

More information

Operating and installation instructions

Operating and installation instructions Check valves Contents 1.0 General information on operating instructions...2-2 2.0 Notes on possible dangers...2-2 2.1 Significance of symbols... 2-2 2.2 Explanatory notes on safety information... 2-2 3.0

More information

DSV. Operating Manual. Double Seal Butterfly Valve. Read and understand this manual prior to operating or servicing this product.

DSV. Operating Manual. Double Seal Butterfly Valve. Read and understand this manual prior to operating or servicing this product. Operating Manual DSV Double Seal Butterfly Valve Read and understand this manual prior to operating or servicing this product. www.sks-online.com UK DSV-UK2.qxp / 10.2005 Table of Contents: Page: 1.

More information

Instructions for installation, operation and maintenance of: GATE VALVE

Instructions for installation, operation and maintenance of: GATE VALVE Instructions for installation, operation and maintenance of: GATE VALVE GEN GAC GAF/GENF TERMOVENT SC Temerin Republic of Serbia Instruction for installation, operation and maintenance: Table of Contents

More information

Operating Instructions

Operating Instructions Operating Instructions Quadax Series Butterfly Valves (with actuator) Version September 2009 müller co-ax ag Gottfried-Müller-Str. 1 74670 Forchtenberg Germany Tel. +49 7947 828-0 Fax +49 7947 828-11 E-Mail

More information

Installation Operation Maintenance

Installation Operation Maintenance Installation Operation Maintenance www.challengervalves.com.au 1 QAD#IM1015 REVC 3.10.15 Index 1. INTRODUCTION 3 1.1 Design Features 1.2 Flange and Pipe Compatibility 3 1.3 Operating Pressures and Temperatures

More information

Soft seated butterfly valves

Soft seated butterfly valves 1 Soft seated butterfly valves Original Installation & Maintenance Instructions www.airpower-gmbh.com 2 Installation 1.Installation in the pipeline 1.1 General remarks: With the installation of the valves

More information

Instruction Manual. Double Acting Hydraulic, Hollow Piston Cylinders RHD Series. Maximum Operating Pressure 700 bar

Instruction Manual. Double Acting Hydraulic, Hollow Piston Cylinders RHD Series. Maximum Operating Pressure 700 bar Double Acting Hydraulic, Hollow Piston Cylinders RHD Series Maximum Operating Pressure 700 bar ABSOLUTE EQUIPMENT PTY LTD 2/186 Granite Street, GEEBUNG QLD 4034 Australia sales@absoluteequipment.com.au

More information

Sediment strainer (Type Y)

Sediment strainer (Type Y) Installation,Operation and Maintenance Manual Serial No. H-V034-E-9 Sediment strainer (Type Y) Contents (1) Be sure to read the following warranty clauses of our product 1 User s Manual (2) General operating

More information

Split Body Valves with Bellows Seal Series Globe Valves Series Angle Valves Series Way-Valves

Split Body Valves with Bellows Seal Series Globe Valves Series Angle Valves Series Way-Valves Installation, Operation, Maintenance Instructions Split Body Valves with Bellows Seal Series 025 300 Globe Valves Series 027 300 Angle Valves Series 028 300 3-Way-Valves 1 GENERAL INFORMATION These instructions

More information

26 Series Stainless Steel 2-way Ball Valves

26 Series Stainless Steel 2-way Ball Valves 1-800-899-0553 26 Series Stainless Steel 2-way Ball Valves Users Manual Installation, Operation, & Maintenance 1. General Precaution 1.1. Material Section Material deterioration is determined by the contained

More information

Operating and installation instructions

Operating and installation instructions Series 470 Series 471 Contents 1.0 General information on operating instructions...2-2 2.0 Notes on possible dangers...2-2 2.1 Significance of symbols... 2-2 2.2 Explanatory notes on safety information...

More information

Operating instructions GEFA / DOMINO valves series AT 200F ATEX II 1D/2DG c

Operating instructions GEFA / DOMINO valves series AT 200F ATEX II 1D/2DG c GEFA / DOMINO valves series AT 200F ATEX II 1D/2DG c Product description The GEFA valves series AT200F are provided for use in the area of solid substances. The valve is usable as a product tight valve.

More information

Flow controller with integrated control valve (PN 16) AHQM - return and flow mounting

Flow controller with integrated control valve (PN 16) AHQM - return and flow mounting Flow controller with integrated control valve (PN 16) AHQM - return and flow mounting Description Controllers are used together with Danfoss electrical actuators: DN 15-32 with - AMV(E) 10 - AMV(E) 13

More information

Flow-compensated temperature controller AVTQ DN 15

Flow-compensated temperature controller AVTQ DN 15 Data sheet Flow-compensated temperature controller AVTQ DN 15 Description AVTQ is a self-acting flow-compensated temperature controller primarily for use in district heating systems with plate heat exchangers

More information

R o L. BUTTERFLY VALVE of carbon steel with flanges series BLUE LINE. Operation. Edition

R o L. BUTTERFLY VALVE of carbon steel with flanges series BLUE LINE. Operation. Edition of carbon steel 31500 series C ont R o L Operation Edition 03-0-009 The welded butterfly valve 31500 is used for example in district heating, district cooling and industry. It can be used as an on-off

More information

Mounting and Operating Instructions EB 8053 EN. Series 250 Type and Type Pneumatic Control Valves

Mounting and Operating Instructions EB 8053 EN. Series 250 Type and Type Pneumatic Control Valves Series 250 Type 3252 1 and Type 3252 7 Pneumatic Control Valves Type 3252 High-pressure valve with Type 3277 Pneumatic Actuator and Type 3767 Electropneumatic Positioner Mounting and Operating Instructions

More information

Operating Instructions Garlock Butterfly Valves DN : mm / 2-24

Operating Instructions Garlock Butterfly Valves DN : mm / 2-24 Operating Instructions Garlock Butterfly Valves DN : 50-600 mm / 2-24 PN : 10 / 16 Type: GAR-SEAL SAFETY-SEAL STERILE-SEAL MOBILE-SEAL Conformity declaration... 14 0 Introduction... 15 1 Proper use...

More information

R o L. BUTTERFLY VALVE of carbon steel with welded ends 313 -series BLUE LINE. Description

R o L. BUTTERFLY VALVE of carbon steel with welded ends 313 -series BLUE LINE. Description of carbon steel 313 -series C ont R o L Description Edition 23-07-2015 The welded butterfly valve 313 is specially designed for district heating and district cooling. It can be used as an on-off or control

More information

PFA LINED BALL VALVES Installation, Operation and Maintenance Manual

PFA LINED BALL VALVES Installation, Operation and Maintenance Manual ACRIS PFA LINED BALL VALVES WWW.AMRESIST.COM Table of Contents Safety Instructions - Definition of Terms............................................2 Introduction..............................................................2

More information

Rate B standard. Rate A Rate A option. max +260 C/ min -40 C

Rate B standard. Rate A Rate A option. max +260 C/ min -40 C of carbon steel 315 -series C ont R o L Description Edition 30-03-2015 The welded butterfly valve 315 is used for example in district heating, district cooling and industry. It can be used as an on-off

More information

Mounting and Operating Instructions EB 8048 EN. Type and Type Pneumatic Control Valves Type 3249 Aseptic Angle Valve

Mounting and Operating Instructions EB 8048 EN. Type and Type Pneumatic Control Valves Type 3249 Aseptic Angle Valve Type 3249-1 and Type 3249-7 Pneumatic Control Valves Type 3249 Aseptic Angle Valve Ball body version Special version with packing Type 3249-7 Control Valve with Type 3277 Actuator and integrated positioner

More information

Two- and three way valves VFG.. / VFGS 2 / VFU.. for self-acting thermostats and electrical actuators

Two- and three way valves VFG.. / VFGS 2 / VFU.. for self-acting thermostats and electrical actuators for self-acting thermostats and electrical actuators Description VFG 2 VFG 21 (see pages 2, 3, 4) Valves for heating, district heating and cooling systems. The valves can be used with following actuators:

More information

73000 Series Masoneilan* Sweep Angle Control Valves Models XX-73471

73000 Series Masoneilan* Sweep Angle Control Valves Models XX-73471 GE Oil & Gas 73000 Series Masoneilan* Sweep Angle Control Valves Models XX-73471 Instruction Manual GE Data Classification: Public THESE INSTRUCTIONS PROVIDE THE CUSTOMER/OPERATOR WITH IMPORTANT PROJECT-SPECIFIC

More information

Operating Instructions ROCO Butterfly Valve with SKG Slider-crank Mechanism, with Electric Multi-turn Actuator

Operating Instructions ROCO Butterfly Valve with SKG Slider-crank Mechanism, with Electric Multi-turn Actuator Operating Instructions ROCO Butterfly Valve with SKG Slider-crank Mechanism, with Electric Multi-turn Actuator 1 Product and Performance Description 2 Design Features of ROCO Butterfly Valve 3 Installation

More information

Pressure relief valve

Pressure relief valve Pressure relief valve Operating manual Series DHV 712 Version BA-2015.10.20 EN Print-No. 300 510 TR MA DE Rev001 ASV Stübbe GmbH & Co. KG Hollwieser Straße 5 32602 Vlotho Germany Phone: +49 (0) 5733-799-0

More information

USERS MA UAL Bellow sealed valve Fig.229, 230, 234, 235 Edition: 1/2008

USERS MA UAL Bellow sealed valve Fig.229, 230, 234, 235 Edition: 1/2008 诲眾 ᓠ 睂睄 睄 ɞ 1/7 ZETKAMA Spółka Akcyjna ul. 3 Maja 12 PL 57-410 Ścinawka Średnia USERS MA UAL Bellow sealed valve Fig.229, 230, 234, 235 Edition: 1/2008 Date: 01.01.2008 CONTENTS 1. Product description

More information

Butterfly valves Figure 56 Installation & Maintenance Instructions

Butterfly valves Figure 56 Installation & Maintenance Instructions KEYSTONE Please read these instructions carefully This symbol indicates important messages and safety instructions. Hazard potentials: disregarding of instructions improper use of product insufficiently

More information

Installation, Operation and Maintenance Guide II NIBCO High Performance Butterfly Valves Series 6822 and 7822

Installation, Operation and Maintenance Guide II NIBCO High Performance Butterfly Valves Series 6822 and 7822 Installation, Operation and Maintenance Guide II NIBCO High Performance Butterfly Valves Series 6822 and 7822 Statements: NIBCO High Performance Butterfly Valves, Series 6822 and 7822, have been designed

More information

TABLE OF CONTENT. 7-Operating mechanisms of Non-return valve with hydraulic damping cylinder

TABLE OF CONTENT. 7-Operating mechanisms of Non-return valve with hydraulic damping cylinder TABLE OF CONTENT Title 1- Tilting-Disc Non-Return valves with counter weight (NVTW) 2-Parts list 3-Installation Non-return valve and Butterfly Valve 4-Dimensions 5-Installation of Non-return valves with

More information

CompoSeal butterfly valves, wafer style Installation & Maintenance Instructions

CompoSeal butterfly valves, wafer style Installation & Maintenance Instructions Please read these instructions carefully This symbol indicates important messages and safety instructions. Intended valve use The valve is intended to be used only in applications within the pressure/temperature

More information

[DRAFT VERSION] For use for company in Europe who will place the product on the market. Please amend which necessary. Document No:

[DRAFT VERSION] For use for company in Europe who will place the product on the market. Please amend which necessary. Document No: Three-Piece ball valve EA-307 Series PED Category I, II EA-307 User Manual English Version [DRAFT VERSION] For use for company in Europe who will place the product on the market. Please amend which necessary.

More information

Installation Operation Maintenance. LSSN Butterfly Valve AGA Approved 50MM - 150MM. QAD#IM6055.REVA

Installation Operation Maintenance. LSSN Butterfly Valve AGA Approved 50MM - 150MM.  QAD#IM6055.REVA LSSN Butterfly Valve Installation Operation Maintenance Licence Number: 5326 www.challengervalves.com.au 1 Index 1. INTRODUCTION 1.1 Design Features 3 1.2 Flange and Pipe Compatibility 4 1.3 Operating

More information

Mounting and Operating Instructions EB 8222 EN. Type 3310/AT and Type 3310/3278 Pneumatic Control Valves. Type 3310 Segmented Ball Valve

Mounting and Operating Instructions EB 8222 EN. Type 3310/AT and Type 3310/3278 Pneumatic Control Valves. Type 3310 Segmented Ball Valve Type 3310/AT and Type 3310/3278 Pneumatic Control Valves Type 3310 Segmented Ball Valve Fig. 1 Type 3310/3278 with positioner Fig. 2 Type 3310/AT Mounting and Operating Instructions EB 8222 EN Edition

More information

Val-Matic 3-Way Tapered Plug Valve

Val-Matic 3-Way Tapered Plug Valve Val-Matic 3-Way Tapered Plug Valve Manual No. CCPV-OM4-1 Operation, Maintenance and Installation Manual INTRODUCTION.2 RECEIVING AND STORAGE 2 VALVE CONSTRUCTION..2 DESCRIPTION OF OPERATION. 3 INSTALLATION

More information

KEYSTONE. Hygienic butterfly valves model F250 & F251 Installation & Maintenance Instructions. 1 Contents 1 Contents 1

KEYSTONE. Hygienic butterfly valves model F250 & F251 Installation & Maintenance Instructions.   1 Contents 1 Contents 1 Installation & Maintenance Instructions KEYSTONE 1 Contents 1 Contents 1 2 Introduction 1 2.1 Valve use 1 2.2. Application area 1 2.3. Incorrect use 1 3. Safety 2 4. Transport and storage 2 5. Installation

More information

Mounting and Operating Instructions EB 8111/8112 EN. Valve Series V2001 Globe Valve Type 3321

Mounting and Operating Instructions EB 8111/8112 EN. Valve Series V2001 Globe Valve Type 3321 Valve Series V2001 Globe Valve Type 3321 Fig. 1 Type 3321 Valve with mounted rod-type yoke for pneumatic or electric actuators (partial view) Mounting and Operating Instructions EB 8111/8112 EN Edition

More information