Low Cost Submersion and In-Line ph Electrodes
|
|
- Conrad Curtis
- 6 years ago
- Views:
Transcription
1 Low Cost Submersion and In-Line Electrodes Economical design for in-line or submersion use Choose from single or double models Threaded 1/2" or 3/4" NPT connections Choose from spherical or flat measuring surfaces Special models for low ionic and other specialty applications available S270 Series Ryton Sensors This series of electrodes is designed to provide an economical multi-purpose solution for in-line or submersion measurements. Based on our proven S200C bulb and S350CD flat surface glass technology, these rugged and durable electrodes are available in Ryton nipples with 1/2" or 3/4" NPT threads; or in our durable epoxy body with or without quick disconnect top caps. Choose from single or double designs, flat or recessed measuring surface configurations and cable lengths and connectors as required. For special configurations such as low ionic models, fluoride resistant glass and other specialty sensors, please contact the Sensorex sales or technical support department. Specifications S260 Series Ryton Sensors Measuring Range material Max Temp/Pressure Connector length Process Connection 0-14 (Sodium ion error >12.3) (S200,S222, S353, S354 Series) or Ryton (S265-S269 Series, S271CD, S272CD & S273CD) S265-S269 Series : deg F ( 0-80 deg C))/70 psig S271CD,S272CD & S273CD : 170 deg F (75 de C))/100 psig, 180 deg F (81 deg C)/85 psig, 212 deg F (100 deg C)/50 psig BNC, tinned wires (other connectors available for an addi tional charge), S353CD AND S353CD have DIN Cap and require DIN-EL mating connector 30" or longer for S200 Series lengths at additional cost user specified (Cap-cable S653 required for S222 Series). 10ft length for S265-S269 series, 10ft waterproof cable for S271CD, S272CD & S273CD 1/2" or 3/4" MNPT for submersion or in-line, S354CD has DIN 13.5mm threads S222 Series Quick Disconnect Models Parts covered by this product data sheet include: S200C, S200CD, S222C, S222CD, S223C, S223CD, S224C, S224CD, S265C-S269CD, S271CD, S272CD, S272CDTC, S273CD, S273CDTC, S353CD, S354CD Page 1 of 6 Form: SpecsGenPurposeElectrodes.indd [Rev: ]
2 Low Cost Submersion and In-Line Electrodes in-line or submersion measurements. S222C S222CD S200C S200CD & S200CD-LC BNC Receptacle BUNA-N o-rings 5.41" BNC Receptacle BUNA-N o-rings 5.41" Blue top cap 6.00" Blue top cap 6.00" S223C S223CD S224C S224CD Page 2 of 6 Form: SpecsGenPurposeElectrodes.indd [Rev: ]
3 Low Cost Submersion and In-Line Electrodes in-line or submersion measurements. S353CD S354CD S6 (DIN 13.5 CAP) 13.5mm Threads Stem Stem 5.9 (150mm) (AgCl) Silicone Bushing 6.0 (152mm) (AgCl) Silicone Bushing 4.8 (122mm) Pelon Reference KNO3 4.8 (122mm) Pelon Reference KNO3 Reference Reference Flat glass Flat glass FC50P and FC75P Amber Color (12 mm) Diameter Porous Reference- S653 Cap and Flat Surface for Conduit use Glass (0.235 / 5.97mm Diameter) (12 mm) Diameter DIN-EL Ext. for DIN Cap Models FC75TC Installation nut COAXIAL CABLE Connectorfor Contro ler Here Cap and cable 3/4" Modified Tee gripper 1/2 NPT S222CD spacer o-ring 1.60" Dimple x4 for grip 2.45" (62mm) Mates to DIN CAP or DIN13.5 FC75P fitting A partno. FC50P FC75P Dim A 1/2 NPT 3/4 NPT 0.83" (21mm) ATC Page 3 of 6 Form: SpecsGenPurposeElectrodes.indd [Rev: ]
4 Low Cost Submersion and In-Line Electrodes in-line or submersion measurements. S265C/CD DIA /2 NPT S267C/CD DIA /4 NPT 1.00 Wrench Flat x 2 S268CD Porous Reference DIA /2 NPT Flat glass DIA S269CD Porous Reference DIA /4 NPT Flat glass DIA Page 4 of 6 Form: SpecsGenPurposeElectrodes.indd [Rev: ]
5 Low Cost Submersion and In-Line Electrodes in-line or submersion measurements. S271CD j u n c t i o n D I A. ( m m ) 7.63 (193.8 mm) p H b u l b 3 / 4 N P T x 2 W r e n c h f l a t x 2 S272CD & S272CDTC FLAT GLASS j u n c t i o n D I A. ( m m ) Temp Sensor Inside stem(s272cdtc) 3 / 4 N P T X (193.8 mm) S273CD W r e n c h f l a t or x 2 S273CDTC S273CD & S273CDTC Hemi GLASS 0.65 DIA. (16.5 mm) Temp Sensor Inside stem(s273cdtc) 3/4 NPT X (193.8 mm) (S273CD) cable + 2 wires for S273CDTC Ordering Information These economical sensors are submersion and in-line ready by utilizing the 1/2" or 3/4 MNPT threads on the sensor. 10ft cable length is standard. Special lengths available upon request. Sensors Material Key Features (To order an ORP model instead of, simply add - ORP to the model numbers below.) S265C PPS Single 1/2" NPT spherical bulb S265CD PPS Double 1/2" NPT spherical bulb S267C PPS Single 3/4" NPT spherical bulb S267CD PPS Double 3/4" NPT spherical bulb S268CD PPS Double 1/2" NPT flat surface S269CD PPS Double 3/4" NPT flat surface S271CD PPS Double 3/4" NPT spherical bulb, heavy duty S272CD PPS Double 3/4" NPT flat surface, heavy duty S272CDTC PPS Double 3/4" NPT flat surface, heavy duty with Temperature Sensor, Pt100 or Pt1000RTD S273CD PPS Double 3/4" NPT hemi glass surface, heavy duty S273CDTC PPS Double 3/4" NPT hemi glass surface, heavy duty with Temperature Sensor, Pt100 or Pt1000RTD Page 5 of 6 Form: SpecsGenPurposeElectrodes.indd [Rev: ]
6 Low Cost Submersion and In-Line Electrodes in-line or submersion measurements. Ordering Information These economical sensors can be used for submersion or in-line use. Mounting is accomplished by ordering the appropriate mounting gland listed below. Mounting glands Sensor S200C S200CD S200CD-LC S222C S222CD Type Single spherical style bulb Double spherical style bulb Low ionic, double, spherical style bulb Single spherical style bulb-quick disconnect Double spherical style bulb-quick disconnect Double flat glass-quick disconnect S223C S223CD S353CD Single spherical style bulb- DIN Cap Double spherical style bulb-din Cap Double flat glass-din Cap DIN 13.5 Threaded Cap Sensors - (Do not require mounting fitting. Mount via DIN 13.5 thread) Color coded buffers Sensor S224C S224CD S354CD Type Single spherical style bulb- DIN 13.5 Cap(S6) Double spherical style bulb-din 13.5 Cap(S6) Double flat glass-din 13.5 Cap(S6) TX100 2-wire transmitter Accessories FC50P FC75P FC75TC S653 EXT - DIN EL/"X" TX100 B104 B107 B110 1/2 " NPT mounting gland for 12mm electrodes 3/4 " NPT mounting gland for 12mm electrodes 3/4 "flow cell, mounting gland and ATC cable for 12mm electrodes Cap assembly for S222 series (Specify cable length and connector termination when ordering) Extension cable for DIN cap and DIN 13.5 electrodes (Series S223, S224, S354) 4-20mA loop-powered transmitter 1 pint 4.01 Buffer 1 Pint 7.00 Buffer 1 Pint Buffer Page 6 of 6 Form: SpecsGenPurposeElectrodes.indd [Rev: ]
Low Cost Submersion and In-Line ph Electrodes
Low Cost Submersion and In-Line Electrodes Economical design for in-line or submersion use Choose from single or double models Threaded 1/2" or 3/4" NPT connections Choose from spherical or flat measuring
More informationSignet DryLoc ph/orp Electrodes
Signet 2774-2777 DryLoc ph/orp Electrodes Features Patented DryLoc connector with gold plated contacts* Special design allows for installation at any angle, even inverted or horizontal Quick temperature
More informationGeneral Purpose ph/orp Sensors
Product Data Sheet PDS 71-3900/rev. B December 2010 Models 3900 and 3900VP General Purpose ph/orp Sensors EXTENDED SENSOR LIFE provided by double junction reference. ENHANCED PERFORMANCE AND INCREASED
More informationSignet ph/orp Electrodes
Signet 2724-2726 ph/orp Electrodes Compatible with ALL Signet ph/orp Instruments Features Flat Glass Protected Bulb Patented reference design for exceptional performance * Mounts in Signet standard fittings
More informationSignet DryLoc ph/orp Electrodes
Signet 2774-2777 DryLoc ph/orp Electrodes Features Patented DryLoc connector with gold plated contacts* Special design allows for installation at any angle, even inverted or horizontal Quick temperature
More informationNEW QUICK CABLE-TO-SENSOR RELEASE,
Models 399 and 399VP Product Data Sheet PDS 71-399 October 2000 ph/orp Sensors NEW OPTIONS to meet a variety of application requirements, including: * Low ionic strength water * Processes with hydrofluoric
More information8000 Series ph/orp Electrode Platform Product Instructions
8000 Series ph/orp Electrode Platform Product Instructions Introduction Congratulations on your purchase of your Sensorex S8000 series electrode platform. The platform is designed in a modular fashion
More informationSignet ph/orp Electrodes
Signet 2724-2726 ph/orp Electrodes Compatible with ALL Signet ph/orp Instruments Features Patented reference design for exceptional performance * Mounts in Signet standard fittings from DN15 to DN100 (½
More informationAP300 Series Combination ph/redox (ORP) Sensors. Measurement made easy. A reliable economic solution for a wide range of applications
Data sheet DS/AP00 EN Rev. F AP00 Series Measurement made easy A reliable economic solution for a wide range of applications Long life large PTFE junction provides resistance to fouling double junction
More informationph/orp Sensor Model 399 ph/orp
Model 399 ph/orp Product Data Sheet PDS 71-399 September 1999 ph/orp Sensor DOUBLE JUNCTION REFERENCE CELL provides longer sensor life in process solutions containing poisoning ions. ONE-PIECE CONSTRUCTION
More informationGeneral Purpose ph/orp Sensors
General Purpose ph/orp Sensors Product Data Sheet LIQ_PDS_3900 September 2013 General Purpose ph/orp Sensors SMART preamplifier-stores calibration and other data. Extended sensor life provided by double
More informationSignet ph/orp Electrodes
Signet 2734-2736 ph/orp Electrodes Compatible with Signet 8900/9900 Instruments Features Patented reference design for exceptional performance * Mounts in Signet standard fittings from DN15 to DN100 (½
More informationABB MEASUREMENT & ANALYTICS DATA SHEET. TBX5 ph, Redox (ORP) sensors with diagnostics
BB MESUREMENT & NLYTICS DT SHEET TBX ph, Redox (ORP) sensors with diagnostics Measurement made easy The most durable ph / Redox (ORP) sensors in the world Next Step Solid State reference eliminates poisoning,
More informationModels 396/396P/396R. Retraction/Submersion/Insertion ph/orp Sensor
Models 396/396P/396R Product Data Sheet PDS 71-TUpH September 1999 Retraction/Submersion/Insertion ph/orp Sensor MINIMUM SENSOR MAINTENANCE due to patented TUpH reference technology 1 which ensures steady
More informationAqua Metrix. Water Analytics AquaMetrix Price List. AquaMetrix products are manufactured by. Water Analytics
2018 AquaMetrix Price List (Rev 2.0/ effective August 2018) AquaMetrix products are manufactured 100 School Street Andover, MA 01810 tel 978-749-9949 toll free 855-747-7623 (855-pHProbe) fax 978-749-9961
More informationGeneral Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.J January 2011
Product Data Sheet PDS 71-400/rev.J January 2011 Model 400 and 400VP Series ENDURANCE General Purpose Conductivity Sensors INITIAL CALIBRATION NOT REQUIRED. Pre-determined cell constant ensures out-of-the
More informationCombination ph/redox (ORP) Sensors
Data Sheet Combination ph/redox (ORP) s Series AP00 User-customizable for Insertion, Flow-through, Immersion, Hot-tap Retractor ideal for Original Equipment Manufacturers and general applications Economical
More informationAnalytical Instruments Two-Electrode Conductivity Sensors
Data Sheet Analytical Instruments Two-Electrode Conductivity Sensors Model TB2 Superior accuracy in low conductivity measurement ranges. Measurement ranges from 0 to 199.9 µs/cm to 0 to 19.99 ms/cm. Resolution
More informationCombination ph/redox (ORP) Sensors
Data Sheet SS/AP00_ Combination ph/redox (ORP) s AP00 Series User-customizable for Insertion, Flow-through, Immersion and Hot-tap Retractor ideal for OEMs (Original Equipment Manufacturers) and general
More information7774 Series Stainless Steel Insertion/Removal Assembly for Use with Meredian Electrodes
7774 Series Stainless Steel Insertion/Removal Assembly for Use with Meredian Electrodes 70-82-25-44 Rev. 1 10/07 Honeywell Process Solutions Copyright, Notices, and Trademarks Copyright 2007 by Honeywell
More informationSignet 3719 ph/orp Wet-Tap
Signet 3719 ph/orp Wet-Tap *3-3719.090* 3-3719.090 Rev H 09/07 English Do not exceed maximum temperature/pressure specifications. Wear safety goggles or face shield during installation/service. Do not
More informationTUpH 396, 396VP, 396P, 396PVP, 396R, 396RVP
TUpH 396, 396VP, 396P, 396PVP, 396R, 396RVP Product Data Sheet LIQ-PDS-396P-PVP-R-RVP April 2016 TUpH 396, 396VP, 396P, 396PVP, 396R, 396RVP Retraction/Submersion/Insertion ph/orp Sensors Smart enabled
More informationAccessories Guide ph/orp/conductivity Sensors
Jet Cleaners and Scrubber Accessories Isolation Ball Valves Assemblies Compression Fittings and Sheath Sets High Pressure (2500 PSIG) Sensor Housings In-line Flow Cells Nut Lock Union Style Adapters Sensor
More informationGeneral Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.I December 2008
Product Data Sheet PDS 71-400/rev.I December 2008 Model 400 and 400VP Series ENDURANCE General Purpose Conductivity Sensors INITIAL CALIBRATION NOT REQUIRED. Pre-determined cell constant ensures out-of-the
More informationSignet 2760 DryLoc ph/orp Preamplifier
Signet 2760 DryLoc ph/orp Preamplifier *3-2760.090* 3-2760.090 Rev. H 05/11 English English SAFETY INSTRUCTIONS 1. Depressurize and vent system prior to installation or removal. 2. Confi rm chemical compatibility
More informationTUpH Retraction/Submersion/Insertion ph/orp Sensors
Product Data Sheet PDS 71-TUpHVP/rev.B June 2003 Models 396VP, 396RVP, 398VP, & 398RVP TUpH Retraction/Submersion/Insertion ph/orp Sensors SILCORE 3 TECHNOLOGY PROVIDES INCREASED SENSOR LIFE when used
More informationSIGNET 2750 ph/orp Sensor ENGLISH
ENGLISH 3-2750.090 B-8/01 English SAFETY INSTRUCTIONS FOR IN-LINE ELECTRODE INSTALLATION 1. Do not remove from pressurized lines. 2. Do not exceed maximum temperature/pressure specifications. 3. Wear safety
More informationModel 7777DVP Immersion/In-Line Mounting for Durafet III ph Electrodes Installation and Maintenance Rev. 1 3/04
Model 7777DVP Immersion/In-Line Mounting for Durafet III ph Electrodes 70-82-25-116 Rev. 1 3/04 Industrial Measurement and Control Copyright, Notices, and Trademarks Printed in U.S.A. Copyright 2004 by
More informationGeneral Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.K February 2013
Product Data Sheet PDS 71-400/rev.K February 2013 Model 400 and 400VP Series ENDURANCE General Purpose Conductivity Sensors INITIAL CALIBRATION NOT REQUIRED. Factory-measured cell constant ensures out-of-the-box
More informationAST10 & AST51 Contacting Conductivity Sensors
AST10 & AST51 Contacting Conductivity Sensors AST10 Contacting Conductivity Sensors in K=3.0/cm cell constant (without cap & without compression fitting) & K=10.0/cm cell constant with Hastelloy C-276
More information* * Rev. 9 01/18 Product Manual
English Signet 2760 DryLoc ph/orp Preamplifier *3-2760.090* 3-2760.090 Rev. 9 01/18 Product Manual Description The Signet 2760 ph/orp Preamplifiers with DryLoc connectors are part of Signet's growing line
More informationPerformance Series ph/orp Sensors
Industrial Process Control & Monitoring Patented Axial Ion Path TM Reference Specialized ph Glass Formulations and ORP Electrodes Proprietary Low-Noise, High Temperature Signal Cable Sensors are Compatible
More informationLiquid Conductivity Two & Four Electrode Sensors
Industrial Process Control & Monitoring Rugged Two Electrode Conductivity Sensors Unique Four Electrode Conductivity Sensors Versatile Installation Options (Threaded, Quick Change, Retractable) Specialized
More informationPerformance Series ph/orp Sensors
Industrial Process Control & Monitoring Patented Axial Ion Path Reference Specialized ph Glass Formulations and ORP Electrodes Proprietary Low-Noise, High Temperature Signal Cable Sensors are Compatible
More informationSIGNET 2760 DryLoc ph/orp Preamplifier
SIGNET 2760 DryLoc ph/orp Preamplifier 3-2760.090 3-2760.090 (A-3/04) English SAFETY INSTRUCTIONS 1. Depressurize and vent system prior to installation or removal. 2. Confirm chemical compatibility before
More informationRetractable ph/orp Sensors
Model 396R and 396RVP Instruction Manual PN 5100396R January 2001 Retractable ph/orp Sensors ESSENTIAL INSTRUCTIONS READ THIS PAGE BEFORE PROCEEDING! Rosemount Analytical designs, manufactures, and tests
More informationGeneral Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.G February 2006
Product Data Sheet PDS 71-400/rev.G February 2006 Model 400 and 400VP Series ENDURANCE General Purpose Conductivity Sensors INITIAL CALIBRATION NOT REQUIRED. Pre-determined cell constant ensures out-of-the
More informationearth safe Fuel Systems for Critical Power
Point Level Sensors S100 Tank Refill Level Sensor 4/5 Point S101 Tank High level Sensor 3 Point S102 Tank Low Level Sensor 1 Point S103 Tank High Level Vent Sensor Level Transmitters S120 Tank Level Transmitter
More informationNBK-M - Economical Level Indicator
316 Stainless Steel Tube Maximum Pressure: 580 PSIG Maximum Temperature: 390 F Measuring Lengths to 9.8 Ft. Optional Switches, Transmitters and Digital Displays Available Economical Rugged Design PRICES
More informationTB4CS Conductivity sensor 4-Electrode. Low maintenance sensor with the widest operation range available (0 to 2000 ms/cm)
Data sheet TB4CS Conductivity sensor 4-Electrode Low maintenance sensor with the widest operation range available (0 to 2000 ms/cm) 4-electrode measurement Increases accuracy, stability, flexibility, and
More informationSignet Conductivity/Resistivity Electrodes
Signet 2818-2823 Conductivity/Resistivity Electrodes 2818 2819 2820 2821 2822 2823 Sanitary Features Standard process connections - Polypro - SS on 10 and 20 cell - Tri-clamp 1-1½ in., 2 - Opt. ½ in. NPT
More informationSignet 2760 DryLoc ph/orp Preamplifiers & Connectors
Signet 2760 DryLoc ph/orp Preamplifiers & Connectors Features In-line integral mount and submersible installation versions Automatic temperature compensation Auto configuration for ph or ORP operation
More informationInsertion/Submersion Flow Through Sensor
Product Data Sheet PDS 71-381/rev.B September 2004 Model 381 ph/orp Insertion/Submersion Flow Through Sensor ADVANCED ON-LINE SENSOR DIAGNOSTICS 1 (Model 381+ only), for use with the Models 54e ph/orp
More information7777D In-Line Mounting for Durafet II ph Electrodes Installation and Maintenance
7777D In-Line Mounting for Durafet II ph Electrodes Installation and Maintenance 70-82-25-121 Rev. 0 3/07 Honeywell Process Solutions Industrial Measurement and Control Copyright, Notices, and Trademarks
More information2015 CONTROLLER PRICE LIST Products / Spare Parts / Accessories
W A L C H E M IWAKI America Inc. Controller Price List 2015 CONTROLLER PRICE LIST Products / Spare Parts / Accessories Five Boynton Road Hopping Brook Park Holliston, MA 01746 USA TEL: 508-429-1110 FAX:
More informationControl Valves Positioner
Control Valves Positioner HiFlo Valve Positioner Easy calibration Corrosion-resistant cover and base Withstands 150 psi at all parts Two -sided cam for easy field reversibility Optional / NPT for piped
More informationControl Valves Positioner
Control Valves Positioner HiFlo HiFlo Valve Positioner Corrosion-resistant cover and base Easy calibration Withstands 150 psi at all parts Two -sided cam for easy field reversibility Optional / NPT for
More informationSignet 4150 Turbidimeter
C L I S T E D 113783 US 4150 Turbidimeter Features Description The 4150 Turbidimeter system provides accurate and reliable compliant water quality monitoring for municipal and industrial applications.
More informationSIGNET 3719 ph/orp Wet-Tap
ENGLISH 3-3719.090 B-6/02 English Do not exceed maximum temperature/pressure specifications. Wear safety goggles or face shield during installation/service. Do not attempt to disassemble the retraction
More informationCombination ph/redox (ORP) Sensors
User Guide IM/AP300_6 Combination ph/redox (ORP) Sensors AP300 Series ABB The Company We are an established world force in the design and manufacture of instrumentation for industrial process control,
More informationRetractable ph/orp Sensors
Instruction Manual PN 51-396R/rev.J February 2011 Model 396R and 396RVP Retractable ph/orp Sensors ESSENTIAL INSTRUCTIONS READ THIS PAGE BEFORE PROCEEDING! Rosemount Analytical designs, manufactures, and
More informationSECTION METERS AND GAGES FOR HVAC PIPING
PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions Specification Sections, apply to this Section. 1.2 SUMMARY A. This
More informationPerformance Series ph/orp Sensors
Industrial Process Control & Monitoring Patented Axial Ion Path TM Reference Specialized ph Glass Formulations and ORP Electrodes Proprietary Low-Noise, High Temperature Signal Cable Sensors are Compatible
More informationSignet Conductivity/Resistivity Electrodes
Signet 2818-2823 Conductivity/Resistivity Electrodes 2818 2819 2820 2821 2822 2823 Sanitary Features Standard process connections - Polypro - SS on 10 and 20 cell - Tri-clamp 1-1½ in., 2 in. - Opt. ½ in.
More informationMINI-NBK ECONOMICAL LEVEL INDICATOR
MINI-NBK ECONOMICAL LEVEL INDICATOR Flow Pressure Level Temperature measurement monitoring control N2 316 Stainless Steel Tube Maximum Pressure: 580 PSIG Maximum Temperature: Measuring Lengths to 9.8 Ft.
More information7774 Series Stainless Steel Insertion/Removal Assembly for Use with Durafet II ph Electrodes Rev. 0 5/99
7774 Series Stainless Steel Insertion/Removal Assembly for Use with Durafet II ph Electrodes 70-82-25-88 Rev. 0 5/99 Copyright, Notices, and Trademarks Copyright 1999 by Honeywell Inc. Revision 0 5/99
More informationSmith Meter PD Meter Meter, PD Series, K12- S1, S3, S5, S6, and S7
Smith Meter PD Meter Meter, PD Series, K12- S1, S3, S5, S6, and S7 Parts List Bulletin PO01018 Issue/Rev 0.1 (7/13) S1, S3, S5 S6, S7 Item Description Qty. K12-S1 K12-S5 K12-S7 Page 2 SS01018 Issue/Rev.
More information7777 Immersion/In-Line Mounting for Meredian II ph/orp Electrodes Installation and Maintenance Manual
7777 Immersion/In-Line Mounting for Meredian II ph/orp Electrodes Installation and Maintenance Manual 70-82-25-05 Rev. 1 3/08 Honeywell Process Solutions Copyright, Notices, and Trademarks Printed in U.S.A.
More informationEncapsulated Differential ph and ORP Sensors (available in LCP, foreground, or Ryton body materials)
Technology For Solutions Data Sheet LRE/102 Supersedes LRE/400 Encapsulated Differential ph and ORP Sensors (available in LCP, foreground, or Ryton body materials) Common Features Differential Electrode
More information7777 Immersion/In-Line Mounting for Durafet II ph Electrodes Installation and Maintenance
7777 Immersion/In-Line Mounting for Durafet II ph Electrodes Installation and Maintenance 70-82-25-86 Rev. 1 4/00 Sensing and Control Copyright, Notices, and Trademarks Printed in U.S.A. Copyright 2000
More informationConductivity Sensors. Model 140, 141, 142. Product Data Sheet series/rev.b February 2011
Product Data Sheet 71-140 series/rev.b February 2011 Model 140, 141, 142 Conductivity Sensors RUGGED CONSTRUCTION withstands high temperature and pressure TWO MOUNTING CONFIGURATIONS: screw-in and retractable
More informationResistance Temperature Detectors (RTDs)
Website: Resistance Temperature Detectors (RTDs) Resistance Temperature Detectors (RTD's). These detectors are frequently used in the plastics industries and many others. Care must be taken to eliminate
More informationDirect immersion resistance thermometer
Direct immersion resistance thermometer PLAIN STEM D100-101-102-103-160-162 CONFIGURATIONS General use RTD Product series PT100WT D100 D101 D102 D103 D160 D162 2 Features assembly The sensor can be immersed
More information871DO-C Dissolved Oxygen Sensors and Sensor Accessories
Product Specifications PSS 6-9B1 A 871DO-C Dissolved Oxygen Sensors and Sensor Accessories 871DO-C REPLACEMENT MEMBRANE CAP ASSEMBLY The 871DO-C Sensor, when used in conjunction with 871DO-C Sensor Accessories
More informationJUMO tecline CR Electrolytic Conductivity Cells in stainless steel or titanium
Page 1/10 JUMO tecline CR Electrolytic Conductivity Cells in stainless steel or titanium 202924 Series (formerly 2 EL6... Series) 2-electrode system for ranges from 0.05 µs/cm to 1 ms/cm large variety
More informationDPT TARGET TYPE FLOWMETERS
DPT TARGET TYPE FLOWMETERS Flow Pressure Level Temperature measurement monitoring control S3 Patented Target/Leaf-Spring Design Minimal Wear Components 1.5-8 to 225-500 GPM Water Line Sizes 3/8 to 3" Wide
More informationSURE JET ENVELOPE FINISHING SYSTEM MODEL EFS
SURE JET ENVELOPE FINISHING SYSTEM MODEL EFS SURE JET VACUUM BASE SJVB SURE JET VACUUM BASE SJDB-EXT Parts Manual SJ_EFS-PARTSBOOK051507reva 1 TABLE OF CONTENTS ENVELOPE FINISHING SYSTEM- SURE JET EFS-SURE
More information871PH Series ph, ORP, and Fluoride Sensors and Accessories
Product Specifications PSS 6-1C2 A 871PH Series ph, ORP, and Fluoride Sensors and Accessories 871PH multi-purpose precision electrochemical sensors, used in conjunction with 871PH accessories, are suitable
More informationPRESSURE TRANSDUCERS. Specifications. Individual Specifications
00 Series and 00 Heavy Duty Series Compact OEM Pressure Transmitters 0 50 psi to 0-0,000 psi ranges (0-.5 bar to 0-,00 bar) High Proof Pressures Broad Choice of Outputs RoHS Compliant For OEMs that need
More informationINSTRUCTION MANUAL MODEL S80 INTELLIGENT SENSORS
INSTRUCTION MANUAL MODEL S80 INTELLIGENT SENSORS PREFACE Purchasing products from Electro Chemical Devices, Inc. provides you with the finest liquid analytical instrumentation available. If this is your
More informationInstrument Enclosure Assemblies
Instrument Enclosure Assemblies Standard instrument enclosure Instrument enclosures offer a simple solution for the customer who doesn t have the time to install Signet meters into panels. Whether it s
More informationAccutubes. Accuracy True double averaging design +1% of rate accuracy +0.1% repeatability Tested and certified by independent flow labs
s Meriam s Flow Sensors are lab-tested and field-proven flow elements perfect for gas, liquid or steam service. With thousands in use worldwide, the continues to be the right choice when ease of installation,
More informationConductivity Sensors. Model 140, 141, 142. Product Data Sheet series/rev.a June 1998
Product Data Sheet 71-140 series/rev.a June 1998 Model 140, 141, 142 Conductivity Sensors HIGH TEMPERATURE 316 SS AND PEEK CON- STRUCTION operates up to 200 C (392 F). MODEL 140 RETRACTABLE SENSOR installs
More informationLTX RF LEVEL SENSOR. Instruction Manual
LTX RF LEVEL SENSOR Instruction Manual FOR MODELS LTX01, LTX02, LTX05 Intempco Document No: LTX - M01 Rev. 1 Issue Date: April 2005 LTX01 RF LEVEL SENSOR USER MANUAL Software Rev : Rev. Date : June 2004
More informationAnalytical Instruments Four-Electrode Conductivity Sensors for Process Monitoring Model TB4
Data Sheet Analytical Instruments Four-Electrode Conductivity Sensors for Process Monitoring Model TB4 Four-electrode measurement: Increases accuracy, stability, flexibility, and security Highest temperature
More informationOMP POSITIVE DISPLACEMENT FLOWMETERS
OMP POSITIVE DISPLACEMENT FLOWMETERS Flow Pressure Level Temperature measurement monitoring control Flow Ranges from 0.53 to 26 GPH to 4 to 92 GPM Handles Viscosities to 1,000,000 cps Pressure Ratings
More informationMWD. Industrial Temperature Assemblies RTD. Meassuring range ºC. Pt100 sensor class A, class B, class 1/3, class 1/10, or Cryogenic.
Industrial Temperature Assemblies measuring monitoring analysing MWD OO Meassuring range -200...+600ºC. OO Pt100 sensor class A, class B, class 1/3, class 1/10, or Cryogenic. OO Output: Resistance or analogue
More informationScrew-in resistance thermometers with plug connector
Data Sheet 90.2004 Page 1/8 s with plug connector for temperatures from -50 to +300 C highly resistant to shock and vibration connector locked in for reliable contact, IP65 or IP69K protection available
More informationPG Series 180º Rotation Pneumatic Actuators
PDF Published April 18, 2016 PG Series 180º Rotation Pneumatic Actuators for Chemline 3-way ball valves up to 4 material: Epoxy and Rilsan coated aluminum SERIES: PGS Spring Return PGD Double Acting control
More informationSignet 3719 ph/orp Wet-Tap Assembly
Signet 3719 ph/p Wet-Tap Assembly Features Electrode removal without process shutdown Space saving 45 mm (1.75 in.) short-stroke design Sealed pneumatic dampening for smooth and safe operation SafeLoc
More informationDigital ph transmitter
Digital ph transmitter Compact, remote versions for DN 15 to 200 Fully programmable ph transmitter functions for all kinds of ph-measurement tasks Large range of process connections with various fittings
More informationDigital ph transmitter
Digital ph transmitter Compact, remote versions for DN 15 to 200 Fully programmable ph transmitter functions for all kinds of ph-measurement tasks Large range of process connections with various fittings
More informationPX409 Series. mv/v, 0 to 5 or 0 to 10 Vdc, or 4 to 20 ma Outputs Uni-Directional Ranges 0-10 inh2o to psid
Micro-Machined Silicon Transducers wet/dry differential mv/v, 0 to 5 or 0 to 10 Vdc, or 4 to 20 ma Outputs Uni-Directional Ranges 0-10 inh2o to 0-1000 psid PX409 Series Standard U 5-Point NIST Traceable
More informationModel 385+ Instruction Manual PN February ph/orp Sensor
Model 385+ Instruction Manual PN 5100385+ February 2001 ph/orp Sensor ESSENTIAL INSTRUCTIONS READ THIS PAGE BEFORE PROCEEDING! Rosemount Analytical designs, manufactures, and tests its products to meet
More informationCOMBINATION ph SENSOR
Instruction Manual PN 51-TF396/rev.G June 2012 Model TF396 COMBINATION ph SENSOR MODEL TF396 with mating cable ESSENTIAL INSTRUCTIONS READ THIS PAGE BEFORE PROCEEDING! Rosemount Analytical designs, manufactures,
More informationortable ph, Conductivity & DO2 Meters
ortable ph, Conductivity & DO2 Meters Enterprise Range Large, back lit LCD Ergonomic design These ergonomically designed products feature a backlit liquid crystal display, a reading hold function and 500
More informationArmstrong In-Line and Insertion Vortex Flow Meters
Armstrong In-Line and Insertion Vortex Flow Meters Designs, materials, weights and performance ratings are approximate and subject to change without notice. Visit for up-to-date information. 1 In-Line
More informationRetractable ph/orp Sensors
Instruction Manual PN 51-398R/rev.G January 2011 Model 398R & 398RVP Retractable ph/orp Sensors MODEL 398R MODEL 398RVP (shown in ball valve) ESSENTIAL INSTRUCTIONS READ THIS PAGE BEFORE PROCEEDING! Rosemount
More informationGF Signet. Measurement & Control Sensors. Signet Price List 1st Aug 2011 Rev 0.0
GF Signet Measurement & Control Sensors Sensors and Transmitters: Flow ph Conductivity ORP Level Pressure Temperature Turbidity Chlorine Installation fittings Power supplies Calibration solutions Accessories
More informationMANUAL & AUTOMATED BALL VALVES
ESTABLISHED 1991 STEALTH VALVE & CONTROLS LTD. The Application Solution Company Exclusive Stocking Distributor for Valves, Actuators, Instruments and Specialty Products Serving: Industrial, Power, Food
More informationENDURANCE Conductivity Sensors
Model 400 Series Instruction Manual P/N 5100400 May 1999 ENDURANCE Conductivity Sensors Model 400 Model 401 Model 402 Model 403 Model 404 Screw-in/Insertion Sensors Screw-in/Insertion Sensors Retractable
More informationRosemount 3300HT/3300HTVP/3400HT/ 3400HTVP/3500P/3500VP
Instruction Manual LIQ-MAN-PERpH-X Rev. J April 2017 Rosemount 3300HT/3300HTVP/3400HT/ 3400HTVP/3500P/3500VP PERpH-X High Performance ph/orp Sensors hasgkas Essential Instructions Read this page before
More informationSignet V(D) to V(D) PVDF Conductivity Electrodes
Signet 2839-1V(D) to 2842-1V(D) PVDF Conductivity Electrodes Features ± 2% accuracy - Custom calibration certificate provided Dual-threaded Compact electrode length for easy in-line installation in small
More informationFor additional information, please visit our website at SENSOR SPECIFICATIONS
Instruction Sheet PN 51A-140/rev.E December 2010 Models 140, 141, and 142 Conductivity Sensors For additional information, please visit our website at www.emersonprocess.com/raihome/liquid/. SENSOR/PROCESS
More informationSTC Manual & Actuated Process Valves
STC Manual & Actuated Process Valves Fine Quality Precision Engineered Excellent Prices Advanced Design connects fluid power to industrial automation Table of Contents STC Valve Numbering System.......2
More informationGeneral Information... Temperature/Resistance Table... Part Numbering Examples for RTD s. High Temperature MgO Elements (RA)...
Page General Information... Temperature/Resistance Table... Part Numbering Examples for RTD s High Temperature MgO Elements (RA).... Leadwire Style RTD s (RB).. Leadwire Style RTD s (RD, RE, RF, or RG
More informationScienceLine ph combination electrodes
Scienceine ph combination electrodes ph combination electrodes with plug head and fixed cable Reference silver/silver chloride system: (See Remarks) Shaft material: glass Zero point: ph = 7.0 ± 0.3 Electrolyte:
More informationph-kompaktelektrodensystem sensopac CPA 320
Technische Information TI 0C/0/de ph-kompaktelektrodensystem sensopac CPA 0 One of the two reference systems is specially protected so that only the second monitoring reference system is affected by penetration
More informationF-2700 SERIES INSERTION VORTEX FLOW METER
F-2700 SERIES INSERTION VORTEX FLOW METER APPLICATIONS Saturated steam Hot water to 500 F (260 C) standard 750 F (400 C) optional Applications with optional pressure sensor Superheated steam to 500 F (260
More informationSERVICE MANUAL / PARTS LIST MODEL XSG-5
ation SERVICE MANUAL / PARTS LIST MODEL XSG-5 1055 Mendell Davis Drive Jackson MS 39272 888-994-7636 601-372-3903 Fax 888-864-7636 unifiedbrands.net PART NUMBER 158634 REV B (11/11) TABLE OF CONTENTS 2
More information