Signet 4150 Turbidimeter

Size: px
Start display at page:

Download "Signet 4150 Turbidimeter"

Transcription

1 C L I S T E D US 4150 Turbidimeter Features Description The 4150 Turbidimeter system provides accurate and reliable compliant water quality monitoring for municipal and industrial applications. The 4150 measures turbidity via a 90 degree light which reflects particles as they flow through a small volume, low flow glass cuvette. Air bubbles are eliminated from the cuvette by adjusting the backpressure valve on the outlet tube. The cuvette is located in a watertight dark chamber for continuously accurate on-line measurement. A replaceable desiccant pack provides a dry-stable environment to ensure reliable measurements. Simple and fast calibration can be accomplished in under five minutes by placing the In-line glass cuvette from the measuring chamber into the cuvette holder while still in service and the inlet and outlet tubing remains connected. The inexpensive calibration standard allows for dry and multiple system calibrations without mixing chemicals. After calibration, the unit is up and running with simple re-insertion of the glass cuvette back into the measuring chamber. Additional features include a message indicator when the desiccant needs replacing and as an option, auto/ ultrasonic cleaning of the glass Inline cuvette for longer runs between maintenance. The 4150 is available in two measuring ranges. The 0 to 100 NTU/FNU version is for low range applications such as drinking water. The 0 to 1000 NTU/ FNU range can be used for various applications including raw water and wastewater reclamation. Simple and easy single unit installation with built-in pressure regulator Versions compliant with either U.S. EPA for North and South America and Asia or ISO 7027 for Europe Time saving and efficiencies of cuvette technology simplifies calibration Spannable 4-20 ma output Two adjustable alarm relays Bright backlit display Convenient holder for In-line cuvette Easy access for wiring and maintenance Ultrasonic cleaning option ensures long and steady on-line measurement Inexpensive standards allow for multiple system calibrations Applications Monitor Filter Performance Raw or Filtered Water Municipal Water Distribution Wastewater Reclamation and Tertiary Effluent Aquatic Life Support Systems Overview 4150 Turbidimeter Mounting Bracket 2 - Power Supply and Wiring Terminals 3 - Operator Interface with Display 4 - Desiccant Access (not shown) 5 - In-line Glass Cuvette (with Ultrasonic option) 6 - Backpressure Valve 7 - Cuvette Holder 8 - Shutoff Clamp 9 - Tubing and Fittings 10 - Measuring Cell Chamber

2 Dimensions Top View Front View 51 mm (2.0 in.) Cuvette Holder Measuring Cell 343 mm (13.5 in.) 226 mm (8.9 in.) Specifications General Flow Rate Range: 0.1 L/min to 1 L/min (0.026 GPM to 0.26 GPM) Measurement Range: 0 to NTU/FNU or 0 to NTU/FNU Accuracy: ±2% of reading or ±0.02 NTU/FNU below 40 NTU/FNU whichever is greater ±5% of reading above 40 NTU/FNU NTU = FNU = FTU Mounting Horizontal plane, integral mounting bracket (with standard hole pattern) Use 4.75 mm (3/16 ) ID, 8 mm (5/16 ) OD flexible tubing for the water supply/ outlet (customer supplied) Maximum Inlet Pressure Integral pressure regulator rated 1380 kpa (200 psig) Maximum Outlet Pressure 100 kpa (15 psig) Operating Temperature/Pressure 1 C to 50 C (34 F to 122 F) (5 to 15 psig) 35 to 105 kpa Power Supply VAC, Hz, 80 VA Insulation Rating Double Insulated Pollution Degree 2 Overvoltage Category II Turbidity Side View 186 mm (7.34 in.) 102 mm (4.0 in.) Resolution up to NTU/FNU (below 10 NTU/FNU) Display Two-Line LCD w/backlight Alarm Relays VAC, 2A Form C Relay Analogue Signal w/field Selectable Range Active 4-20 ma, 600 Ω or RS485 Wetted Materials Tubing: Vinyl Measuring cuvette: Borosilicate Glass Glass washer seal: Silicone Pressure regulator: Polypropylene 316 stainless steel Delrin by Dupont Inlet tube: 316 stainless steel Altitude 2000 meters (6,561 ft) maximum Relative Humidity Maximum 95% RH non-condensing Enclosure Rating IP 66 /NEMA 4X Environmental Conditions Not recommended for outdoor use Shipping Weight 2.5 kg 5.5 lb Standards and Approvals CE Compliant to U.S. EPA Compliant to ISO 7027 ETL Listed UL and CSA C22.2 No Glass cuvette with ultrasonic transducer Glass cuvette without ultrasonic transducer (not shown) Ordering Information Part Number Measurement Range and Self Cleaning Options -1 White Light, 0 to 1000 NTU/FNU, no self cleaning U.S. EPA Infrared, 0 to 1000 NTU/FNU, no self cleaning ISO White Light, 0 to 100 NTU/FNU, with ultrasonic auto self cleaning U.S. EPA Infrared, 0 to 100 NTU/FNU with ultrasonic auto self cleaning ISO White Light, 0 to 1000 NTU/FNU, with ultrasonic auto self cleaning U.S. EPA Infrared, 0 to 1000 NTU/FNU with ultrasonic auto self cleaning ISO Example Part Number Mfr. Part No. Code Mfr. Part No. Code Accessories and Replacement Parts Mfr. Part No. Code Description Calibration kit, turbidity, 100, 10 & 0.02 NTU/FNU Calibration kit, turbidity, 1000, 10 & 0.02 NTU/FNU Replacement desiccant Formazin stock kit Formazin stock solution, 4000 NTU/FNU, 500 ml Replacement cuvette set (3 glass cuvettes) Replacement cuvette with ultrasonic transducer O-ring kit for cuvette 77

3 6 7 8 RELAY RELAY 2 ph ENTER Monitor RELAY RELAY 2 ph ENTER Monitor ph and ORP Electrodes Compatible with ALL Instruments Features Patented DryLoc connector with gold plated contacts Description Flat Glass The ph and ORP Electrodes features a patented reference electrode design and uses the unique foul-proof patented DryLoc connector. The large area PE reference junction and pathway is constructed to increase the total reference effectiveness and ensures long service life. The DryLoc connector with corrosion resistant gold plated contacts readily connects the sensor to the mating 2760 preamplifier or the 2750 sensor electronics. The robust Ryton threaded sensor body and choice of flat ph, bulb ph, or flat ORP sensing elements provides broad range of chemical compatibility for a wide variety of applications. Protected Bulb There are two optional ph sensing versions available, HF and LC. The HF version is for applications where traces of hydrofluoric acid (2% or less) will attack standard ph glass in levels of ph 6 and below. The LC version can be used for low conductivity fluids ( μs/cm recommended). The quick temperature response is available in either a PT1000 or 3 KΩ temperature sensor and allows compatibility with all ph/ ORP instruments. The electrodes are general-purpose sensors ideal for a wide range of applications. The sensors incorporate ¾ NPT or ISO 7/1-R 3/4 threads for installing into standard pipe-tees. They can also be mounted directly into standard fittings, ½ to 4 inch. Mounts in standard fittings from DN15 to DN100 (½ to 4 in.) ¾ NPT or ISO 7/1-R 3/4 threaded sensors for use with reducing tees up to 4 in. Special design allows for installation at any angle, even inverted Ryton (PPS) body for broad range of chemical compatibility Patented* reference design for exceptional performance Quick temperature response HF resistant glass available for trace HF of <2% Optional Low conductivity sensor for liquids down to 20 μs/cm Applications System Overview In-Line Installation Panel Mount 4 to 20 ma Input Instrument Chart Recorder Programmable Logic Controller (sold separately) DryLoc Electrodes and Threaded only for in-line installs 2750 (sold separately) Ryton (PPS) is a registered trademark of Chevron Phillips Chemical Co. LLC Go to for more information on Ryton OR DryLoc Electrodes PLC Submersible Installation Panel, Pipe, Tank, Wall Mount Instrument or Pipe extension or conduit with 3/4 in. NPT or ISO 7/1-R 3/4 threads (customer supplied) DryLoc Electrodes Water & Wastewater Treatment Neutralisation Systems Effluent Monitoring Sanitisation Systems Pool & Spa Control Aquatic Animal Life Support Systems Process Control Cooling Towers See Technical Reference section for assistance in choosing the correct sensor. U.S. Patent No.: 6,666,701 *Patents pending 78

4 Dimensions Flat electrode 0.64 mm (0.25 in.) mm (1.75 in.) Yes 0 Horizontal 18.3 mm (0.72 in.) 109 mm (4.3 in.) Threads: ¾ in. NPT or ISO 7/1 R-3/ mm (1.0 in.) Bulb Electrode 9.3 mm (0.37 in.) Yes mm (2.1 in.) Yes Specifications General Performance Efficiency: 25 C (77 F) Operating Range: ph: 0 to 14 ph ORP: ±2000 mv LC: Low Conductivity fluids; μs/cm recommended HF: Hydrofluoric acid resist glass, ph 6 or below; trace HF <2% Compatibility: 2750 Electronics, 2760 Preamplifier ph Temperature Sensor: PT1000 versions are compatible with 2750 Sensor electronics for connection to a PLC or to the 8900 Multi- Parameter Controller. 3 KΩ Balco versions are compatible with the preamplifier for connection to the 5700 Monitor and the 8750 Transmitter. Process Connection: ¾ in. NPT ISO 7/1-R 3/4 Mounts into fittings Recommended Storage Temperature The best storage temperature for the 272X ph and ORP electrodes is 0 C to 50 C (32 F to 122 F) The electrode glass will shatter if shipped or stored at temperature below 0 C (32 F) The performance life of the electrode will shorten if stored at temperatures above 50 C (122 F) Mounting In-line Mounting: Use the sensor threads Use a standard fitting up to 4 in. Sensor can be mounted at any angle Submersible Mounting: Use threads on models 2750 or 2760 Requires ¾ inch NPT or ISO 7/1-R 3/4 male threaded liquid tight extension conduit. Shipping Weight 0.25 kg 0.55 lb Yes Yes Yes Mounting Angle Models may be mounted at any angle without affecting the performance. Avoid locations with air pockets and sediment. Wetted Materials ph: Ryton (PPS), glass, UHMW PE, FPM ORP: Ryton (PPS), glass, UHMW PE, FPM, Platinum Max. Temperature/Pressure Rating Operating Temperature Range:* -10 C to 85 C (14 F to 185 F) Operating Pressure Range: -10 C to 65 C (14 F to 149 F): 0 to 100 psi 65 C to 85 C (149 F to 185 F), linearity derated 100 psi to 58 psi Standards and Approvals Manufactured under ISO 9001 for Quality and ISO for Environmental Management *Best performance for 2726-HF sensors is above 10 C (50 F) See Temperature and Pressure Graphs for more information for more information 79

5 Electrode Key Features and Benefits: 4 1. Ryton body for chemical compatibility with most harsh chemicals. 2. Porous UHMW PE (ultra high molecular weight polyethylene) junction resists fouling and build-up. 3. Internal temperature sensor located in the glass stem for a quick temperature response. 4. DryLoc connector with corrosion resistant gold pins for quick and easy sensor removal. Resists moisture and dirt intrusion Threads for NPT or ISO process connection into reducing tees Use off-the-shelf GF reducing tees DN20 to DN100 (¾ to 4 in.). Mounts directly into fittings (½ in. 4 in.) for easy sensor retrofitting. Mount submersed into a tank via the 2750 or 2760 back threads Sensor in threaded reducing tee 6 Sensor in fitting 7 Sensor submersible installation Accessories Buffer Solutions The ph buffers are ideal for routine calibration requirements. The liquid solutions are conveniently packaged in one pint (473 ml) bottles. ph buffer kits in powder pillows are available for mixing fresh solutions with water at the time of use. All ph buffers are colour coded for easy identification; 4.01 ph is red, 7.00 ph is yellow, and ph is blue. All ph buffers are traceable to NIST standards. These buffer solutions can be used to calibrate ORP sensors when saturated with quinhydrone. 80

6 Model Ordering Notes 1) ph and ORP electrodes require connection to model 2750 sensor electronics or 2760 preamplifier. 2) Use the flat glass electrodes when a self-cleaning feature is desired; especially useful in applications with abrasive chemicals. 3) Use bulb protected electrodes for general purpose applications. 4) ORP electrodes are generally used for chemical reaction monitoring, not control. 5) The 2750 EasyCal feature recognises common ph and ORP buffer values of 4, 7 and 10 ph and 87 and 264 mv for ORP. Application Tips Use the flat glass electrodes when a self-cleaning feature is desired; especially useful in applications with abrasive chemicals. Use bulb protected electrodes for general purpose applications ORP electrodes are generally used for chemical reaction monitoring, not control. Ensure that sensor materials are chemically compatible with the process liquid. Keep electrode tip wet, avoid air pockets and sediment. Ordering Information ph Electrodes Flat glass ph Bulb glass ph HF Bulb glass ph, HF resistant 2% HF LC Bulb glass ph, Low conductivity applications, μs/cm recommended Temperature Element - Choose One -0 PT1000; use with 2750 sensor electronics* -1 3 KΩ Balco; use with 2760 preamplifier** Threaded Process Connection 0 ¾ in. MNPT, Thread 1 ISO 7/1-R 3/4 Thread Example Part Number ORP Electrodes Flat ORP with 10 k Ohm ID Resistor Threaded Process Connection 0 ¾ in. MNPT, Thread 1 ISO 7/1-R 3/4 Thread Example Part Number *The 2750 sensor electronics has a digital (S 3 L) output which is used with the 8900 Controller. It also has a 4 to 20 ma output for connections to PLC s, data recorders, etc. **The 2760 preamplifier is used for connection directly to 5700 Monitor or 8750 transmitter. Mfr. Part No. Code Mfr. Part No. Code Mfr. Part No. Code LC LC HF LC HF LC HF HF Accessories and Replacement Parts Mfr. Part No. Code Description Calibration kit: includes 3 PP cups, cup stand, 1 pint ph 4.01, 1 pint ph gm bottle Quinhydrone for ORP calibration (must use ph 4.01 and/or ph 7.00 buffer solutions) System Tester (adapter cable sold separately) DryLoc Adapter Cable (for use with 2750 and 2760) ph Buffer Kit (1 each 4, 7, 10 ph buffer in powder form, makes 50 ml of each) ph 4.01 buffer solution, 1 pint (473 ml) bottle ph 7.00 buffer solution, 1 pint (473 ml) bottle ph buffer solution, 1 pint (473 ml) bottle 81

7 RELAY 1 RELAY ORP Monitor ENTER DryLoc Electrodes Features Durable DryLoc connector with gold plated contacts Special design allows for installation at any angle, even inverted Quick temperature response Description The ph and ORP Electrodes feature a unique foul-proof DryLoc connector with gold-plated contacts designed specifically for use with the 2750 and 2760 preamplifiers, sensor electronics, and connectors. These dependable and highly responsive electrodes feature a PTFE double reference junction with KNO 3 in the front chamber to block various poisoning ions such as Copper (CU ++ ), Lead (Pb ++ ), Mercury (Hg ++ ), and a large reference chamber that combine to extend the servicelife. Embedded positioning of the System Overview Panel Mount Instrument or 4 to 20 ma Input Chart Recorder OR 2750 Programmable Logic Controller PLC Flat Glass Protected Bulb In-Line Installation temperature element in the ph sensing tip allows, the temperature response to be quick and accurate. The electrodes are offered with either flat or bulb style sensing elements. The flat versions allow sediment and particles to sweep past the measurement surface, minimizing risks of abrasion, breakage and coating. The bulb versions can be used for general-purpose applications. Due to the specially designed chambers which keep electrolyte in place, all versions can be installed at any angle, even inverted. Pipe, Tank or Wall Mount Other Instruments Instrument Customer supplied 8750 Universal Adapter Kit (3-8050) Flow Submersible Installation Panel, Pipe, Tank, Wall Mount or Other Instrument Pipe extension or conduit with 3/4 in. FNPT threads (customer supplied) 2750 or Easy sensor replacement using DryLoc electrode connector High temperature versions available Mounts into standard ¾ inch threads Compatible with all instruments Applications Water Treatment & Water Quality Monitoring Demineraliser, Regeneration & Rinse Cooling Tower and Boiler Protection Aquatic Animal Life Support Systems Pool and Spa Control Neutralisation Systems DryLoc Electrodes DryLoc Electrodes Fittings - Customer supplied See Technical Reference section for assistance in choosing the correct sensor. 82

8 Dimensions 35.5mm (1.4 in.) 128.3mm (5.05 in.) 43mm (1.7 in.) 3/4 in. NPT 22.8mm (0.9 in.) 35.5mm (1.4 in.) 38.6mm (1.52 in.) 29.2mm (1.15 in.) 22.1mm (0.87 in.) Bulb Electrode 38.6mm (1.52 in.) 29.2mm (1.15 in.) 0.64 mm (0.25 in.) insertion depth, typical Specifications General Compatibility: Models 2750 and 2760 Operating Range: 2774/2776: 0 to 14 ph 2775/2777: +/-2000 mv (ORP) Process Connection: ¾ in., for use in reducing tees up to 4 in Reference: Electrolyte: KNO 3 /KCl acrylamide gel Element: Ag/AgCl Primary Functions: 2774 and 2775: Flat surface resists fouling 2776 and 2777: Bulb surface for general use Wetted Materials Body: Ryton Reference junctions: PTFE Sensing surface: Glass membrane: (ph) Platinum: (ORP) O-rings: FPM Recommended Storage Temperature The best storage temperature for the 272X ph and ORP electrodes is 0 C to 50 C (32 F to 122 F) The electrode glass will shatter if shipped or stored at temperature below 0 C (32 F) The performance life of the electrode will shorten if stored at temperatures above 50 C (122 F) Mounting In-line/vertical mounting: Use the electrodes ¾ inch threads to install into pipe fitting. Electrode can be mounted at any angle. Submersible mounting: Use threads on Model 2750 or 2760; requires ¾ inch NPT or ISO 7/1-R 3/4 male threaded extension. Temperature Sensor: ph: 3 KΩ or PT1000 RTD ORP: none Shipping Weight 0.25 kg 0.55 lb 128.3mm (5.05 in.) 32mm (1.3 in.) 3/4 in. NPT 22.1mm (0.87 in.) Flat Electrode 0.64 mm (0.25 in.) insertion depth, typical Max. Temperature/Pressure Rating Operating Temperature: 0 C to 85 C (32 F to 185 F) Maximum Operating Pressure: 6.9 bar (100 psi) Storage Temperature: > 0 C (32 F) Higher temperature and pressure sensors are available. Standards and Approvals Manufactured under ISO 9001 for Quality 83

9 Electrode Key Features and Benefits: Ryton body for chemical compatibility to most harsh chemicals. Also able to withstand high temperatures. Porous PTFE reference junctions are highly chemically resistant; resists fouling and dirt buildup. First reference chamber with KNO 3 protects Ag/AgCl wire for a prolonged sensor life. Capillary TC (temperature sensor) embedded in tip of ph electrode for quicker temperature response than most other electrodes on the market. DryLoc connector with corrosion resistant gold pins for quick and easy sensor removal. Reference Ag/AgCl Wire Double Porus PTFE Reference Junctions DryLoc Connector Ryton Body Reference Electrolyte Chamber 1 st Reference Chamber with KNO 3 Model Ordering Notes 1) ph and ORP sensors require connection to model 2750 or ) Conduit and mounting brackets for submersible installation must always be used (customer supplied). 3) All of these sensors can be installed upsidedown. 4) Special order options may have longer delivery time. Consult your local Georg Fischer sales representative for lead times. Electrode Capillary TC Electrode Cut-Away View Application Tips Use the flat glass electrodes for in-line ph sensor applications when a self-cleaning feature is desired; especially useful in applications with abrasive chemicals. Use bulb protected electrodes for general purpose applications ORP electrodes are generally used for chemical reaction monitoring, not control. Ensure that sensor materials are chemically compatible with the process liquid. Keep electrode tip wet, avoid air pockets and sediment. 84

10 Ordering Information Electrode Part Number- Choose Either a ph or ORP Electrode ph Electrodes Flat ph surface electrode Bulb ph electrode with bulb protection Temperature Element - Choose One - 3K Ohm RTD for ph for connection to 8750 or 5700 instruments when used with the 2760 preamplifier** -1 PT1000 RTD for ph for connection to the 8900 when used with the 2750 sensor electronics* Special Order Options for ph Electrodes - Options -HT and -C can only be used with the Preamplifier. (These options cannot be used with the 2750 or 2760) -HT For high temperature and high pressure applications, up to 110 C ( psig; DryLoc connector is removed and replaced with a 4.6 m (15 ft) cable. -C Remove DryLoc connector and add 4.6m (15 ft) cable. Other cable lengths are available -ISO ISO 7/1-R 3/4 Threaded electrodes are available. ORP Electrodes Flat ORP surface electrode Bulb ORP electrode with bulb protection Temperature Element - Choose One - 10 K ID resistor for ORP electrodes for connection to the 8750 and 5700 when used with the 2760 preamplifier or the 8900 when used with the 2750 sensor electronics -1 No T.C. for ORP electrodes for use with other suppliers instruments when used with the 2760 connector Special Order Options for ORP Electrodes - Options -HT and -C can only be used with the Preamplifier (These options cannot be used with the 2750 or HT For high temperature and high pressure applications, up to 110 C ( psig; DryLoc connector is removed and replaced with a 4.6 m (15 ft) cable. -C Remove DryLoc connector and add 4.6 m (15 ft) cable. Other cable lengths are available -ISO ISO 7/1-R 3/4 Threaded electrodes are available Example Part Number *The 2750 sensor electronics has a digital (S 3 L) output which is used with the 8900 Controller. It also has a 4 to 20 ma output for connections to PLC s, data recorders, etc. **The 2760 preamplifier is used for connection directly to 5700 Monitor or 8750 transmitter. Mfr. Part No. Code Mfr. Part No. Code Accessories and Replacement Parts Mfr. Part No. Code Description Calibration kit: includes 3 PP cups, cup stand, 1 pint ph 4.01, 1 pint ph gm bottle Quinhydrone for ORP calibration (must use ph 4.01 and/or ph 7.00 buffer solutions) ph buffer kit (1 each 4, 7, 10 ph buffer in powder form, makes 50 ml of each) ph 4 buffer solution, 1 pint (473 ml) bottle ph 7 buffer solution, 1 pint (473 ml) bottle ph 10 buffer solution, 1 pint (473 ml) bottle system tester Adapter cable for use with 2750/ Remote mount preamplifier Please refer to Wiring, Installation, and Accessories sections for more information. 85

11 RELAY ORP Monitor ENTER Differential DryLoc Electrodes Features Differential design for stable measurements in the most aggressive applications Long service life even in severe or difficult chemical applications Water-tight DryLoc connector with foulproof gold contacts Description The Differential ph & ORP electrodes are built with the DryLoc connector, a Ryton body, and PTFE reference junction to handle the most extreme and harshest of chemical applications. These differential electrodes use a field-proven 3-electrode differential technique: the ph and reference electrodes are measured against a ground electrode, insuring a steady and stable signal. A key feature is the reference electrode, which is housed in a glass half-cell embedded in the reference chamber and is protected from compounds that may contain sulfides (S2 - ) and metals. To ensure long service life, the reference features a refillable electrolyte chamber and a replaceable equitransferant salt bridge, both easily serviced in the field. The patented porous PTFE reference junction resists fouling, clogging and chemical attack. System Overview Panel Mount Instrument RELAY Programmable 8750 Logic Controller 2750 or 4 to 20 ma Input Chart Recorder OR 2750 In-Line Installation PLC Other elements of the design are the solution ground, the electrodes, and the temperature element. The solution ground eliminates noisy measurements by draining electrical current away from the reference electrode. The electrodes are designed with a flat or bulb measurement surface, and a temperature device that is positioned at the tip of the measurement surface, making the temperature response of T 95% less than 1 minute. Various temperature devices offered include 3 KΩ, 300 Ω, or PT1000 RTD. The electrodes are used with the 2750 Sensor Electronics, which provide a blind 4 to 20 ma output or use the digital (S 3 L) output to connect the 8900 Multi-Parameter Controller. The electrodes can also be used with the Model 2760 preamplifier to connect to the 5700 or Pipe, Tank or Wall Mount Other Instruments Instrument Customer supplied Universal Adapter Kit (3-8050) Flow Submersible Installation Panel, Pipe, Tank, Wall Mount or Other Instrument Pipe extension or conduit with 3/4 in. FNPT threads (customer supplied) 2750 or Porous PTFE reference junction Rebuildable reference electrode Solution ground Temperature sensor (ph) Easy sensor replacement using DryLoc electrode connector Quick temperature response Compatible with all and other suppliers instruments Applications Water and Waste Water Treatment Coagulation and Flocculation Plant Effluent Plating Baths Scrubbers Textile Dye Process Harsh Chemical Applications Heavy metal Removal and Recovery Toxics Destruction Surface Finishing Differential Electrodes Differential Electrodes Fittings - Customer supplied See Technical Reference section for assistance in choosing the correct sensor. 86

12 Dimensions 35.6mm (1.4 in.) mm (5.27 in.) 1 in. NPT 38.6 mm (1.52 in.) 32.5 mm (1.28 in.) 25.4 mm (1.0 in.) 0.63 mm (0.25 in.) insertion depth, typical 28.7 mm (1.13 in.) Specifications General Compatibility: 2750 and 2760 Operating Range: 2764/2766: 0 to 14 ph 2765/2767: +/-1500 mv (ORP) Process Connection: 1 in., for use in reducing tees up to 4 in. Wetted Materials Body: Ryton Reference Junctions: PTFE Sensing Surface: Glass membrane: (ph) Platinum: (ORP) O-rings: FPM Solution Ground: carbon graphite Max. Temperature/Pressure Rating Operating Temperature: 0 C to 95 C (32 F to 203 F) Max. Operating Pressure: 6.89 bar ( C (203 F) Storage Temperature: > 0 C (32 F) Mounting In-line/vertical mounting: Use sensor 1 inch threads. Sensor must be mounted at least 15 degrees above the horizontal axis. Submersible mounting: Use threads on Model 2750 or 2760; requires ¾ inch NPT or ISO 7/1-R 3/4 inch male threaded extension. Reference: Electrolyte: 3.5 M KCl, solidified acrylamide gel Element: Ag/AgCl Temperature Sensor: ph: 3 KΩ, PT1000 RTD, or 300 Ω ORP: 10K ID Resistor, PT1000 RTD, or 300 Ω Primary Functions: 2764 and 2765: Flat surface resists fouling 2766 and 2767: Bulb surface for general use Flat and Bulb versions have the same dimensions Recommended Storage Temperature The best storage temperature for the 276X ph and ORP electrodes is 0 C to 50 C (32 F to 122 F) The electrode glass will shatter if shipped or stored at temperature below 0 C (32 F) The performance life of the electrode will shorten if stored at temperatures above 50 C (122 F) Shipping Weight 0.25 kg 0.55 lb Standards & Approvals Manufactured under ISO 9001 for Quality A Differential electrode solves many common problems typically experienced by standard electrodes at troublesome measuring points. See the table below to find the common problem, cause and effect, and the Differential electrode solution. If the standard ( Models 272X or 277X) electrode experiences the following: *Reading slowly drifts over time *Sensor responds slowly *Reading slowly drifts over time *Sensor reading becomes erratic *Reading suddenly jumps to a new value *Reading unexpectedly changes The cause and effect of the problem may be: *Chemical attack from Hg ++, Cu +, Pb ++, ClO 4 - or other compounds which dilute the KCl reference electrolyte concentration. *Reference junction gets clogged from oils, grease, and dirt from the process. *Chemical attack of the Ag+ reference billet from Br -, I -, CN -, and S 2 - compounds. *Clogged reference and slowed reading from silver compounds forming on the inside of the reference electrode from Ag + of reference element reacting and precipitating AgS, AgBr, AgI, AgCN, or other silver compounds. *Stray electrical currents in the process liquid; Ag + reference element picks up current and shifts reference reading, resulting in shifted ph reading. The Ag + element will eventually become totally stripped. Process must be properly grounded or place metal rod close to electrode. Use a Differential Electrode to solves the problem because: *Salt bridge will slow or stop attack. If attacking ions penetrate the salt bridge and affect the KCl, simply refill KCl solution *Readings do not drift due to stable Differential reference design, however may require cleaning or replacement of the salt bridge if electrode gets too dirty. *Will not affect electrode due to Ag + element protected in glass encased reference electrode. *Will not affect electrode due to Ag + element protected in glass encased reference electrode *Will not affect electrode due to Ag + element protected in glass encasement; also, electrode has a built in solution ground, so if there is a stray current, it will not be seen by the electrode Ion Ion name Ion Ion name Compound Compound name Br - Bromide Hg ++ Mercury KCl Potassium Chloride Cu + Copper iron - CIO 4 Perchlorate AgS Silver sulfide CN - Cyanide Ag + Silver AgBr Silver bromide I - Iodide - S 2 Sulfide AgI Silver iodide Pb ++ Lead AgCN Silver cyanide 87

13 Electrode Key Features and Benefits: Glass encased reference electrode protects the Ag/AgCl (silver/silver chloride) element from reacting with certain chemical compounds that typically leach into the reference chambers. Keeps the reading stable. Large volume reference electrolyte chamber resists dilution over time for a long service life. Chamber is refillable. Holds approximately 30 ml of electrolyte Salt Bridge serves as a double reference junction and is the first line of defence to keep out process chemicals from the reference electrolyte chamber. It is built with a porous PTFE reference junction which is highly compatible to chemicals, resists fouling and build-up of dirt. Ryton body for chemical compatibility to most harsh chemicals. Also able to withstand high temperatures. DryLoc connector with corrosion resistant gold pins for quick and easy sensor removal. Capillary TC (temperature sensor) embedded in tip of electrode for quicker temperature response than most other electrodes on the market. Removable/replaceable reference salt bridge Electrode Cut-Away View Glass enclosed reference silver chloride element Reference Chamber with electrolyte Temperature Element electrode Solution ground Application Tips Use the flat glass electrodes when a self-cleaning feature is desired; especially useful in applications with abrasive chemicals. Use bulb protected electrodes for general purpose applications ORP electrodes are generally used for chemical reaction monitoring, not control. Ensure that sensor materials are chemically compatible with the process liquid. Keep electrode tip wet, avoid air pockets and sediment. 88

14 Model Ordering Notes 1) ph and ORP electrodes require connection to model 2750 or ) Conduit and mounting brackets for submersible installations must always be used (customer supplied) 3) Adapters from 1-1½ in. are available. 4) Use sensor threads for in-line mounting; Model 2750 or 2760 threads for submersible mounting. 5) Reference electrode can be rebuilt with replacement electrolyte and salt bridge. Ordering Information Electrode Part Number- Choose Either a ph or ORP Electrode ph Electrode Flat ph surface differential electrode Bulb ph differential electrode with bulb protection Temperature Element - Choose One -1 3K Ω for ph for connection to 8750 or 5700 instruments when used with the 2760 preamplifier** -2 PT1000 RTD for ph for use with the 8900 instrument when used with the 2750 sensor electronics* Ω for connection to other instruments when used with the 2760 preamplifier or connector** ORP Electrode Flat ORP surface differential electrode Bulb ORP differential electrode with bulb protection Temperature Element - Choose One KΩ ID resistor for connection to 8750 or 5700 when used with the 2760 preamplifier or connection to the 8900 with the 2750 sensor electronics -2 PT1000 RTD for connection to other instruments using the 2760 preamplifier or connector Ω for connection to other instruments using the 2760 preamplifier or connector** Example Part Number *The 2750 sensor electronics has a digital (S 3 L) output which is used with the 8900 Controller. It also has a 4 to 20 ma output for connections to PLC s, data recorders, etc. **The 2760 preamplifier is used for connection directly to 5700 Monitor or 8750 transmitter. Mfr. Part No. Code Mfr. Part No. Code Accessories and Replacement Parts Mfr. Part No. Code Description Calibration kit: includes 3 PP cups, cup stand, 1 pint ph 4.01, 1 pint ph gm bottle Quinhydrone for ORP calibration (must use ph 4.01 and/or ph 7.00 buffer solutions) Replacement salt bridge Replacement reference electrolyte solution, 500 mls CPVC adapter: 1.5 in. MNPT to 1 in. FNPT PVDF adapter: 1.5 in. MNPT to 1 in. FNPT ph buffer kit (1 each 4, 7, 10 ph buffer in powder form, makes 50 ml of each) ph 4 buffer solution, 1 pint (473 ml) bottle ph 7 buffer solution, 1 pint (473 ml) bottle ph 10 buffer solution, 1 pint (473 ml) bottle system tester Adapter cable for use with 2750/

15 6 7 8 RELAY RELAY 2 ph ENTER Monitor Flow 3719 Wet-Tap Assembly Features 3719 Assembly Description The 3719 Wet-Tap allows installation and removal of ph or ORP electrodes, even under process pressure, without the need for process shutdown during routine electrode maintenance and calibration. Automatic process isolation is achieved during electrode retraction with a double O-ring seal on a unique and compact retraction assembly; Wet-Tap Electrode no separate valve is required. A patented cam-activated automatic locking mechanism, SafeLoc, and the short stroke design help to assure operator safety. The wet-tap unit can be mounted at any angle and can be used with the DryLoc Wet- Tap electrodes. Electrode removal without process shutdown Space saving 45 mm (1.75 in.) short-stroke design Sealed pneumatic dampening for smooth and safe operation SafeLoc : Cam- activated automatic locking mechanism Protects electrode sensing surface from breakage Suitable for mounting in any orientation Process threaded connection NPT or ISO Low profile clampon saddle fittings for convenient installation in ASTM pipe sizes 2½ to 12 in. Applications System Overview Panel Mount Instrument 2750 or 2760 (sold separately) 4 to 20 ma Input Chart Recorder OR Programmable Logic Controller PLC 2750 (sold separately) Wet-Tap Installation Pipe, Tank or Wall Mount Instrument (sold separately) Universal Adapter Kit (3-8050) 2760 Other Instruments (customer supplied) connector (-3 or -4 only) Aquatic Animal Life Support Systems Recreational Water Monitoring Water & Wastewater Treatment Effluent Monitoring Neutralisation Systems Sanitisation Systems Pool and Spa Control 3719 Wet-Tap Assembly 2756-WT, 2756-WTP 2757-WT, 2757-WTP + GF PP Clamp-On Saddles for 3719 Wet-Tap or GF Tees and Fittings see model 3719 for more info 90

16 Dimensions Specifications X For pipe sizes up to 4 in. Pipe thread 1.5 in. NPT or ISO 7-R mm (3.25 in.) insertion depth, typical 39 mm (1.52 in.) 76 mm (3.0 in.) 49 mm (1.94 in.) 75 mm (2.94 in.) 25 mm (1.00 in.) 45 mm (1.75 in.) 20 mm (0.8 in.) 130 mm (5.13 in.) X For pipe sizes 6 to 12 in Wet-Tap General Compatible DryLoc Electrodes: 2756-WT, 2756-WT-1 (glass) 2756-WTP, 2756-WTP-1 (plastic) 2757-WT (glass) 2757-WTP (plastic) Process Connection: : NPT 1½ in : NPT 2 in : ISO 7/1 - R : ISO 7/1 - R 2 Maximum Flow Velocity: 3 m/s (10 ft/s) Materials Retraction Housing (Wetted): CPVC O-rings (Wetted): FPM Locking Shroud: PVC Hardware: 316 stainless steel Max. Temperature/Pressure Rating Operating Pressure: 100 psi (6.9 bar) maximum Operating Temperature: See Temperature/Pressure graphs for more information Shipping Weight 1.2 kg 2.7 lb Standards/Approvals Manufactured under ISO 9001 for Quality and ISO for Environmental Management Pipe thread 2 in. NPT or ISO 7-R mm (3.25 in.) insertion depth, typical 39 mm (1.52 in.) 76 mm (3.0 in.) 130 mm (5.13 in.) 34 mm (1.32 in.) 75 mm 41 mm (2.94 in.) (1.62 in.) 20 mm (0.8 in.) 45 mm (1.75 in.) Model 3719 Ordering Information 1) Use a mounting saddle or a standard threaded part to mount Wet-Tap assembly. 2) ASTM fittings are available to order; metric fittings are customer supplied. 3) Use -11 or -12 versions for pipe sizes up to 4 in. 4) Use -21 or -22 versions for pipe sizes 6 to 12 inches. Low Profile Clamp-on Saddle Fittings Materials Saddle body (Wetted): Polypropylene (Grade 8, ASTM D2565, 1-8, UV stabilized) Gasket (Wetted): FPM Saddle Hardware: 316 stainless steel Reinforcement Ring: 430 stainless steel Size range: 2½ to 12 in. (ASTM) Ordering Information Wet-Tap Part Number Wet-Tap Assembly Mounting Options - Choose one -11 1½ inch NPT process threads for 2½ to 4 in. pipes -12 ISO 7/1-R 1.5 process threads for 2½ to 4 in. pipes inch NPT process threads for 6 to 12 in. pipes -22 ISO 7/1-R 2 process threads for 6 to 12 in. pipes Example Part Number Mfr. Part No. Code Mfr. Part No. Code

17 Specifications 2756-WT and 2757-WT Wet-Tap Electrodes General Compatibility: 3719 Wet-Tap Assembly, 2750 sensor electronics or 2760 preamplifier Operating Range: ph: 0 to 14 ph ORP: Application dependent Connector (CPVC): DryLoc Temperature Sensor (ph): PT1000 or 3K Balco for ph Response time, τ : 438 secs. Reference junctions: Porous PTFE Electrolyte: 3.5M KCl Elements: Ag/AgCl Performance Efficiency: > 25 C (77 F) Response Time ph: < 5s for 95% of signal change ORP: Application dependent Impedance (ph): < C Sodium Ion Error: < 0.05 ph in 0.1 molar Na+ ion at 12.8 ph Wetted Materials Body: Glass or PAS (Poly Aryl Sulphone) Reference Junctions: Porous PTFE Sensing surface: Glass membrane (ph) Platinum (ORP) O-rings: FPM Connector: CPVC Max. Temperature Rating Operating Temperature: 0 C to 85 C (32 F to 185 F) Storage Temperature: 0 C to 85 C (32 F to 185 F) Mounting: Any angle is acceptable. Use with 3719 wet-tap assembly for mounting electrodes. Shipping Weight 0.2 kg 0.4 lb Standards and Approvals Manufactured under ISO 9001 for Quality Dimensions Wet-Tap ph Wet-Tap ORP 35 mm (1.4 in.) 218 mm (8.57 in.) 11.9 mm (0.47 in.) Product selection Guide: Step 1 - Choose Sensor Step 2 - Choose preamplifier or sensor electronics Step 3 - Choose Wet-Tap assembly Step 4 - Choose mounting option 1 Wet-Tap ph or ORP Sensor: WT WT WTP WTP WT WTP 2 OR OR 2760 Preamplifier: Connector: Sensor Electronics: Wet-Tap Assembly: Wet-Tap Assembly: Wet-Tap Assembly: OR OR Georg Fischer Tees and Fittings 3719 Clamp-On Saddles: Clamp-On Saddles:

18 Model Ordering Notes 1) ph and ORP electrodes require connection to model or -2 or 2760-X1. Ordering Information Wet-Tap Assembly Compatible Electrodes WT DryLoc ph (glass) Electrode (Used with 2750 sensor electronics) - PT WT-1 DryLoc ph (glass) Electrode (Used with 2760 Preamplifier) - 3 KΩ WT DryLoc ORP (glass) Electrode (Used with 2750 sensor electronics or 2760 preamplifier) WTP DryLoc ph (plastic) Electrode (Used with 2750 sensor electronics) - PT WTP-1 DryLoc ph (plastic) Electrode (Used with 2760 Preamplifier) - 3 KΩ WTP DryLoc ORP (plastic) Electrode (Used with 2750 sensor electronics or 2760 preamplifier) *The 2750 sensor electronics has a digital (S 3 L) output which is used with the 8900 Controller. It also has a 4 to 20 ma output for connections to PLC s, data recorders, etc. **The 2760 preamplifier is used for connection directly to 5700 Monitor or 8750 transmitter. Mfr. Part No. Code Mfr. Part No. Code WT WTP WT WT WTP WTP Accessories and Replacement Parts Mfr. Part No. Code Description Calibration kit: includes 3 PP cups, cup stand, 1 pint ph 4.01, 1 pint ph gm bottle Quinhydrone for ORP calibration (must use ph 4.01 and/or ph 7.00 buffer solutions) Mounting Saddles PP Clamp-on Saddle, 2.5 x 1.5 in. (ASTM, NPT) PP Clamp-on Saddle, 3 x 1.5 in. (ASTM, NPT) PP Clamp-on Saddle, 4 x 1.5 in. (ASTM, NPT) PP Clamp-on Saddle, 6 x 2 in. (ASTM, NPT) PP Clamp-on Saddle, 8 x 2 in. (ASTM, NPT) PP Clamp-on Saddle, 10 x 2 in. (ASTM, NPT) PP Clamp-on Saddle, 12 x 2 in. (ASTM, NPT) Other O-ring, FPM (spare part) O-ring, EPR (EPDM) Locking Shroud (spare part) ph buffer kit (1 each 4, 7, 10 ph buffer in powder form, makes 50 ml of each) ph 4 buffer solution, 1 pint (473 ml) bottle ph 7 buffer solution, 1 pint (473 ml) bottle ph 10 buffer solution, 1 pint (473 ml) bottle Please refer to Wiring, Installation, and Accessories sections for more information. 93

19 2750 DryLoc Sensor Electronics Features In-line integral mount and submersible installation versions Automatic temperature compensation For fittings up to 4 in. and wet tap assemblies. In-line 2750 Submersible 2750 In-line when electrode has ¾ in. or 1 in. process connection DryLoc Electrodes sold separately. Auto configuration for ph or ORP operation Optional EasyCal calibration aid with automatic buffer recognition Junction boxes for convenient wiring Description The 2750 Sensor Electronics featuring the DryLoc connector, provides a variety of functions to suit various requirements. The 2750 has a preamplified signal and features two different outputs: a two-wire 4 to 20 ma loop output with EasyCal function or a digital (S 3 L) output which allows for longer cable lengths and is compatible with the 8900 Multi-Parameter Controller. The 2750 self-configures for ph or ORP operation via automatic recognition of the electrode type. The optional EasyCal feature allows simple pushbutton calibration and includes an LED indicator for visual feedback. The DryLoc electrode connector quickly forms a robust assembly for submersible and in-line installations. NEMA 4X junction enclosures are integral parts of the 2750 in-line version and are also available as accessories for the submersible The 2750 submersible preamplifier can also be used as an In-line preamplifier when used with the 3/4 or 1 threaded sensors including the 2724, 2774 and 2764 series electrodes. The 2750 In-line preamplifier can be used with fittings up to DN100 (4 in.) and wet-tap assemblies. Applications Water/Wastewater Treatment Neutralisation Systems Scrubber Control Effluent Monitoring Surface Finishing Flocculent Coagulation Heavy Metal Removal and Recovery Toxics Destruction Sanitisation Systems Pool & Spa Control Aquatic Animal Life Support Systems System Overview Panel Mount 8900 Multi-Parameter Controller In-Line Installation 4 to 20 ma Input Chart Recorder Programmable Logic OR Controller PLC Submersible Installation Panel Mount 8900 Multi-Parameter Controller Wet-Tap Installation 4 to 20 ma Input Chart Recorder OR Programmable Logic Controller PLC 2750 Sensor Electronics Universal junction box ( ) EasyCal (sold separately) 2750 Sensor Electronics Pipe extension or conduit with 3/4 in. NPT or ISO 7/1-R 3/4 threads (customer supplied) 2750 Sensor Electronics with Wet-Tap Electrode 2756, 2757 (each sold separately) 2750 Sensor Electronics DryLoc Electrodes , , Sensor Electronics 3719 Wet-Tap DryLoc Electrodes: Use GF Fittings* or 3/4 in. NPT fittings (customer supplied) and DryLoc Electrodes: Use 3/4 in. or 1 in. NPT fittings (customer supplied) *See Fittings section for more information. DryLoc Electrodes , , GF PP Clamp-On Saddles for 3719 Wet-Tap or GF Tees and Fittings see model 3719 for more info 94

20 Dimensions ,-2 1/2 in. FNPT , mm (1.25 in.) 70.1mm (2.76 in.) 94 mm (3.7 in.) 56.6mm (2.23 in.) 140 mm (5.5 in.) 3/4 in. ISO or 3/4 FNPT threads 89.4mm (3.52 in.) Specifications General Compatible Electrodes: DryLoc ph and ORP Electrodes Models , Wet-Tap, , , Operating Range: ph: 0 to 14 ph ORP: ± 2,000 mv Response Time: ph: < 6 sec. for 95% of change ORP: application dependent Materials: In-line: Valox (PBT) submersible: CPVC Electrical Cable: 4.6 m/15 ft, 3-conductor shielded 22 AWG, 100 ft max. Power: 12 to 24 VDC ±10%, regulated for 4 to 20 ma output 5 to 6.5 VDC ±5% regulated recommended, 3 ma max., for digital (S 3 L) output Current output: ph: Fixed 4 to 20 ma, isolated, = 0 to 14 ph (custom scaling available) ORP: Fixed 4 to 20 ma, isolated, = to 2000 mv (custom scaling available from ± 2000 mv) Max Loop Resistance: 100 Ω 12 V 325 Ω 18 V 600 Ω 24 V Accuracy: ± 32 μa Resolution: ± 5 μa Update Rate: 0.5 seconds Error indication: 3.6 ma Electrical (continued) Update Rate: 0.5 seconds Available Data: Raw mv, ph or ORP, temperature (ph) Error indication: Open input diagnostic Input Impedance, Z: >10 11 Ω Environmental Enclosure: & -2: NEMA 4X/IP65 with electrode connected & -4: NEMA 6P/IP68 with electrode and watertight conduit and/or extension pipe connected Max. Temperature/Pressure Rating Operating Temperature: Temperature (submersible): 0 C to 85 C (32 F to 185 F) Temperature (in-line): 0 C to 110 C (32 F to 230 F) Storage Temperature: -20 C to 85 C (-4 F to 185 F) Relative Humidity: 0 to 95%, non-condensing (without electrode connected) Shipping Weight & 2: 0.75 kg 1.65 lb & -4: 0.64 kg 1.41 lb Standards and Approvals CE Manufactured under ISO 9001 for Quality and ISO for Environmental Management Digital (S 3 L) output: Serial ASCII, TTL level 9600 bps Accuracy: ph: ± C (77 F) ORP: ± 2 25 C (77 F) Resolution: ph: 0.01 ph ORP: 1 mv Temp.: 0.2 C (32.3 F) Valox is a registered trademark of the General Electric Company 95

21 2750 Product Selection Guide 1. Choose the Electrode , Differential , , HF-00, LC-00, and 2757 Wet-Tap WT WTP WT WTP 2. Determine the mounting style: In-line or or or or or or or -2 -In-line fitting Submersible fitting ¾ reducing tee or -4 and cable conduit (customer supplied) connected to ¾ sensor electronics 1 threaded tee ¾ reducing tee Wet-Tap Assembly (Submersible not applicable with Wet-Tap assembly) 3. Junction Boxes : Use when extending the submersible cable over long distance : Use with the submersible or -4 and the in-line for best calibration results with the EasyCal function when using the blind 4 to 20 ma output. 4. Choose the output instrument Digital (S 3 L) 4 to 20 ma OR 8900 Multi-Parameter Controller PLCs or Chart Recorders PLC 96

22 Model 2750 Ordering Information 1) Model 2750 requires 12 to 24 VDC to function as a blind 4 to 20 ma output transmitter. 2) Order a or any other 2750 with a junction box if the EasyCal feature is desired. 3) Conduit and mounting brackets for submersion installation must always be used (customer supplied). 4) The System Tester must be ordered with the adapter cable for exclusive use with the ) All sensor electronics, preamplifiers and connectors require a DryLoc electrode for full system installation. Ordering Information Sensor Electronics with preamplified signal and Digital (S 3 L) output (for use with the 8900 controller) or 4 to 20 ma output - power supplied to unit dictates output type. -1 In-line Sensor electronics (yellow body) - recommended for 8900 Controller -2 In-line Sensor electronics with EasyCal (yellow body) - recommended for 4 to 20 ma use -3 Submersible Sensor electronics with 4.6 m (15 ft) cable and ¾ in. NPT threads - when 4 to 20 ma is required use the junction box with EasyCal -4 Submersible Sensor electronics with 4.6 m (15 ft) cable and ISO 7/1R 3/4 threads - when 4 to 20 ma is required use the junction box with EasyCal Example Part Number Mfr. Part No. Code Application Tips The EasyCal feature automatically recognises standard 4.0, 7.0, and 10.0 ph buffer or ORP Quinhydrone solutions of 87 and 264 mv and simplifies calibration Frequency of calibration of electrodes is dependent upon the application. Accessories and Replacement Parts Mfr. Part No. Code Description Calibration Calibration kit: includes 3 PP cups, cup stand, 1 pint ph 4.01, 1 pint ph gm bottle Quinhydrone for ORP calibration (must use ph 4.01 and/or ph 7.00 buffer solutions) system tester (adapter cable sold separately) adapter cable for use with 2750 DryLoc sensor electronics ph buffer kit (1 each 4, 7, 10 ph buffer in powder form, makes 50 ml of each) ph 4 buffer solution, 1 pint (473 ml) bottle ph 7 buffer solution, 1 pint (473 ml) bottle ph 10 buffer solution, 1 pint (473 ml) bottle Mounting Universal mount junction box Universal mount junction box w/easycal (for submersible applications, use with /4 where 4 to 20 ma is required) Liquid tight connector kit, NPT (1 connector) Liquid tight connector kit, PG 13.5 (1 connector) Other Sensor cable (per ft), 3-cond. plus shield, 22 AWG, black/red/white (for use with 2750) 97

23 6 7 8 RELAY RELAY 2 ph ENTER DryLoc Preamplifiers & Connectors Features In-line integral mount and submersible installation versions For fittings up to 4 in. and wet tap assemblies. In-line 2760 Description The Preamplifiers features the DryLoc connector, providing a robust connection to DryLoc electrodes. The 2760 preamplifier allows any DryLoc electrode to work with ProcessPro and ProPoint instruments. It is also sold as a simple connector for use with other manufacturers instruments that do not require a preamplified signal. Submersible 2760 In-line when electrode has ¾ in. or 1 in. process connection DryLoc Electrodes sold separately. The DryLoc electrode connector system quickly forms a robust assembly for submersible and in-line installations. NEMA 4X junction enclosures are to extend the preamplifier cable to long distances. The 2760 submersible preamplifier can also be used as an In-line preamplifier when used with the ¾ in. or 1 in. threaded sensors including the 2724, 2774 and 2764 series electrodes. The 2760 In-line preamplifier can be used with fittings up to DN100 (4 in.) and wettap assemblies. Automatic temperature compensation Auto configuration for ph or ORP operation Junction boxes for convenient wiring Applications Water/Wastewater Treatment Neutralisation Systems Scrubber Control Effluent Monitoring Surface Finishing Flocculent Coagulation Heavy Metal Removal and Recovery Toxics Destruction Sanitisation Systems Pool & Spa Control Aquatic Animal Life Support Systems System Overview Panel Mount Instrument 5700, 8750 Preamplifier In-Line Installation Pipe, Tank, Wall Mount Transmitter 8750 Universal Adapter Kit (3-8050) Preamplifier Submersible Installation Panel, Pipe, Tank, Wall Mount Instrument Monitor Pipe extension or conduit with 3/4 in. NPT or ISO 7/1-R 3/4 threads (customer supplied) Wet-Tap Installation Panel Mount Instrument 5700, 8750 Preamplifier with Wet-Tap Electrode 2756, 2757 (each sold separately) Pipe, Tank, Wall Mount Transmitter 8750 Universal Adapter Kit (3-8050) DryLoc Electrodes , , and Preamplifier 3719 Wet-Tap DryLoc Electrodes: Use GF Fittings* or 3/4 in. NPT fittings (customer supplied) and DryLoc Electrodes: Use 3/4 in. or 1 in. NPT fittings (customer supplied) DryLoc Electrodes , , GF PP Clamp-On Saddles for 3719 Wet-Tap or GF Tees and Fittings see model 3719 for more info 98

24 Dimensions , -2, -3, mm (1.25 in.) 70.1mm (2.76 in.) 56.6mm (2.23 in.) 89.4mm (3.52 in.) , -21, -31, mm (4.0 in.) 35.0 mm (1.38 in.) 61.0 mm (2.40 in.) 3/4 in. ISO or 3/4 FNPT threads 3/4 in. ISO or 3/4 FNPT threads Specifications General Compatible Electrodes: DryLoc ph and ORP Electrodes Models , Wet-Tap , All ph sensors used with the 2760 must have a 3K Temperature sensor Operating Range: ph: 0 to 14 ph ORP: ± 2,000 mv Response Time*: ph: < 6 sec. for 95% of change ORP: application dependent Materials: In-line: Valox (PBT) Submersible: CPVC Electrical Cable: 4.6 m/15 ft, supplied, 120 m/400 ft max 6 cond., foil shield with drain wire, 24 AWG Environmental Enclosure: Submersible: NEMA 6P/IP68 with electrode and watertight conduit and/or extension pipe connected In-line: NEMA 4 with electrode and watertight conduit and/or extension pipe connected Max. Temperature/Pressure Rating Operating Temperature: Temperature (submersible): 0 C to 85 C (32 F to 185 F) Temperature (in-line): 0 C to 110 C (32 F to 230 F) Storage Temperature: -20 C to 85 C (-4 F to 185 F) Relative Humidity: 0 to 95%, non-condensing (without electrode connected) Shipping Weight 0.64 kg 1.41 lb Standards and Approvals CE Manufactured under ISO 9001 for Quality and ISO for Environmental Management Valox is a registered trademark of the General Electric Company 99

25 RELAY 1 RELAY 2 ENTER 2760 Product Selection Guide 1. Choose the Electrode , Differential , , HF-10, LC-10, and 2757 Wet-Tap WT WTP WT WTP 2. Determine the mounting style: In-line or or or or or or or -21 -In-line fitting fitting ¾ reducing tee 1 threaded tee ¾ reducing tee Submersible or -2 and cable conduit (customer supplied) connected to ¾ sensor electronics Wet-Tap Assembly (Submersible not applicable with Wet-Tap assembly) 3. Junction Boxes : Use when extending the submersible cable over long distance : Use with the submersible or -2. For simple calibration with the EasyCal function. 4. Choose the instrument ph Monitor OR

26 Model 2760 Ordering Information 1) Conduit and mounting brackets for submersion installation must always be used (customer supplied). 4) The System Tester must be ordered with the adapter cable for exclusive use with the ) All sensor preamplifiers and connectors require a DryLoc electrode for full system installation. 6) Use Models , 2756-WT, 2757-WT, and ph and ORP electrodes with the Ordering Information Preamplifier and Connector Preamplifier (for use with the 8750 or 5700 instrument) or Connector (for use with other manufacturer s instruments) with 4.6 m (15 ft cable) Preamplifier -1 Preamplifier, with ¾ in. NPT threads and 4.6 m (15 ft) cable -2 Preamplifier, with ¾ in. ISO threads and 4.6 m (15 ft) cable Connectors (for use with other manufacturer s instruments) -3 Connector with 4.6 m (15 ft) cable and ¾ in. NPT threads -4 Connector with 4.6 m (15 ft) cable and ISO 7/1R 3/4 threads Mounting Configurations - Submersible mounting (gray body) 1 In-line mounting (yellow body); use for wet-tap sensors Example Part Number Mfr. Part No. Code Application Tips The EasyCal feature automatically recognises standard 4.0, 7.0, and 10.0 ph buffer or ORP Quinhydrone solutions of 87 and 264 mv and simplifies calibration Frequency of calibration of electrodes is dependent upon the application. Accessories and Replacement Parts Mfr. Part No. Code Description Calibration system tester (adapter cable sold separately) adapter cable for use with 2750 and 2760 DryLoc sensor electronics ph buffer kit (1 each 4, 7, 10 ph buffer in powder form, makes 50 ml of each) ph 4 buffer solution, 1 pint (473 ml) bottle ph 7 buffer solution, 1 pint (473 ml) bottle ph 10 buffer solution, 1 pint (473 ml) bottle Calibration kit: includes 3 PP cups, cup stand, 1 pint ph 4.01, 1 pint ph 7.00) gm bottle Quinhydrone for ORP calibration (must use ph 4.01 and/or ph 7.00 buffer solutions) Mounting Universal mount junction box Universal mount junction box w/easycal Liquid tight connector kit, NPT (1 connector) Liquid tight connector kit, PG 13.5 (1 connector) Other Cable, 6-cond. plus shield, 24 AWG, black/red/white (for use with 2760, orders must specify length per foot) 101

27 5700 Monitor Member of the ProPoint Family of Monitors Features Displays ph/temp/mv or ORP/mV EasyCal simplifies routine calibration Simple push-button operation Intuitive software design System Overview Analogue and Digital Display Description The 5700 Monitor is a versatile and intelligent instrument that recognises the type of sensor connected, either ph or ORP, then automatically sets itself for the corresponding display and functionality. Also, during EasyCal operation, the monitor automatically recognises standard buffers/test solutions, thereby shortening and simplifying routine calibration procedures. Two programmable relays and one scaleable 4 to 20 ma output are included, and the four-button keypad arrangement with intuitive software design is very userfriendly. The monitors require 12 to 24 volts ±10%, regulated, AC or DC, and can be used with many electrodes and preamplifiers, or with electrodes from other manufacturers by using the 2721 Preamplifier. Several useful accessories are available, including the optional splashproof rear cover kit. In-Line Sensor Installation Submersible Sensor Installation WetTap Sensor Installation Panel Mount 5700 Instrument Panel Mount 5700 Instrument Panel Mount 5700 Instrument Scaleable 4 to 20 ma output internally powered (active) Two programmable relays Dual proportional control capability Non-volatile memory Versatile low voltage power requirement Applications Water & Wastewater Treatment Neutralisation Scrubber Control Effluent Monitoring Surface Finishing Heavy Metal Removal and Recovery Toxics Destruction Sanitisation Systems Pool & Spa Control Aquatic Animal Life Support Systems Process Control MEASURING EQUIPMENT 77CJ compatible Electrode with Preamplifier , , , 2760 (each sold separately) Pipe extension or conduit with 3/4 in. NPT or ISO 7/1-R 3/4 threads Wet-Tap Electrode 2756, 2757 with Preamplifier 2760 (each sold separately) GF Fittings* *See Fittings Section for more information. compatible Electrode with Preamplifier , , , 2760 (each sold separately) 3719 WetTap GF PP Clamp-On Saddles for 3719 Wet-Tap or GF Tees and Fittings see model 3719 for more info 102

28 Dimensions Panel Gasket 91 mm (3.6 in.) 96 mm (3.8 in.) Front View Optional Splashproof Rear Cover # Mounting Panel Mounting Clamp (2 ea.) Side View 76 mm (3 in.) 96 mm (3.8 in.) 88 mm (3.5 in.) Side View 96 mm (3.8 in.) 88 mm (3.5 in.) Specifications General Operating Range: ph: 0 to 14 ph, optically isolated Temp: -25 C to 120 C (-13 F to 248 F) ORP: -2,000 to +2,000 mv, optically isolated Accuracy: ± 0.2% of scale Display Analogue: Reversible dial: 0 to 14 ph or ±1000 mv Digital: Backlit LCD, 2x16 alphanumeric character Materials Enclosure: ABS Plastic Keypad: Silicone Rubber Panel and case gasket: Neoprene Window: Hard-coated polycarbonate Electrical Power Requirements: 12 to 24 VAC or DC ±10%, regulated recommended, 50 to 60 Hz, 10W max. Current Output: 4 to 20 ma, non-isolated, active, internally powered Electrical (continued) Loop Impedance: 350 Ω 12V 950 Ω 24V Accuracy: ± 0.1% Alarm Contacts: Two SPDT relays: 30 VDC 125 VAC 250 VAC max. High/low/pulse programmable with adjustable hysteresis Dual proportional control capability, maximum pulse rate 300 pulses/min. Environmental Operating Temperature: -10 C to 55 C (14 F to 131 F) Relative Humidity: 0 to 95%, non-condensing Enclosure: NEMA 4X/IP65 front Shipping Weight 0.82 kg 1.81 lb Standards and Approvals CE, UL, CUL Manufactured under ISO 9001 for Quality and ISO for Environmental Management Model 5700 Ordering Information 1) Panel cutout should be 92 x 92mm (3.62 x 3.62 in.) 2) Reversible dials with standard ranges for ph and ORP are included with the instrument 3) An optional splashproof rear cover can be ordered separately if needed. 4) Protective overlays are available for the front panel. 5) Order RC filter kits to protect relays from voltage spikes. 6) To mount the unit onto a wall, use the heavy duty wall mount bracket. Please refer to Wiring, Installation, and Accessories sections for more information. Ordering Information Mfr. Part No. Code Description Monitor Accessories and Replacement Parts Mfr. Part No. Code Description Mounting Splashproof rear cover kit x 5 inch adapter plate to retrofit older installations Surface mount bracket (panel mount only) ¼ DIN retrofit adapter Heavy duty wall mount bracket (panel mount only) Liquid Tight Connectors Liquid tight connector kit for rear cover (3 connectors) Liquid tight connector kit, NPT (1 connector) Liquid tight connector kit, PG 13.5 (1 connector) Other Installation kit series window kit Bezel, 5000 series ph buffer kit (1 each 4, 7, 10 ph buffer in powder form, makes 50 ml of each) Protective overlay kit (10 pcs) RC filter kit (for relay use), 2 per kit 103

29 8750 Transmitters Member of the ProcessPro Family of Instruments Features Automatic temperature compensation Temperature display in C or F Hold and simulate functions Relay options available Output scaleability Optional Dual output Panel Mount Pipe, Tank, Wall Mount NEMA 4X/IP65 enclosure with selfhealing window Description The 8750 Transmitter is designed for broad application and ease of setup and use. The unit autoconfigures for either ph or ORP use when connected to ph or ORP electrodes. Multiple mounting options allow for installation best suited to your particular application. The EasyCal menu features automatic buffer recognition for mistake-proof ph or ORP electrode calibrations. Intuitive software and the four button keypad arrangement make it easy to access important information such as ph or ORP, mv input, temperature, calibration, relay setup menus and more. EasyCal option available Applications Neutralisation Systems Heavy Metals Recovery Plating Control Scrubber Control Pool and Spa Control Environmental Study Water Treatment Water Quality Monitoring Waste Treatment Disinfection System Overview MEASURING EQUIPMENT 77CJ LEAD FREE Pb RoHS COMPLIANT Panel Mount 8750 Instrument In-Line Sensor Installation Pipe, Tank, Wall Mount 8750 Instrument Submersible Sensor Installation Panel, Pipe, Tank, Wall Mount 8750 Instrument Panel Mount 8750 Instrument Wet-Tap Sensor Installation Pipe, Tank, Wall Mount 8750 Instrument Universal Adapter Kit Pipe extension or conduit with 3/4 in. NPT or ISO 7/1-R 3/4 threads Universal Adapter Kit Preamplifier electrode Preamplifier electrode Wet-Tap Electrode 2756, 2757 with Preamplifier 2760 (each sold separately) 3719 Wet-Tap GF Fittings* or customer supplied fittings GF PP Clamp-On Saddles for 3719 Wet-Tap or GF Tees and Fittings see model 3719 for more info *See Fittings Section for more information

Signet DryLoc ph/orp Electrodes

Signet DryLoc ph/orp Electrodes Signet 2774-2777 DryLoc ph/orp Electrodes Features Patented DryLoc connector with gold plated contacts* Special design allows for installation at any angle, even inverted or horizontal Quick temperature

More information

Signet ph/orp Electrodes

Signet ph/orp Electrodes Signet 2724-2726 ph/orp Electrodes Compatible with ALL Signet ph/orp Instruments Features Flat Glass Protected Bulb Patented reference design for exceptional performance * Mounts in Signet standard fittings

More information

Signet ph/orp Electrodes

Signet ph/orp Electrodes Signet 2724-2726 ph/orp Electrodes Compatible with ALL Signet ph/orp Instruments Features Patented reference design for exceptional performance * Mounts in Signet standard fittings from DN15 to DN100 (½

More information

Signet DryLoc ph/orp Electrodes

Signet DryLoc ph/orp Electrodes Signet 2774-2777 DryLoc ph/orp Electrodes Features Patented DryLoc connector with gold plated contacts* Special design allows for installation at any angle, even inverted or horizontal Quick temperature

More information

Signet ph/orp Electrodes

Signet ph/orp Electrodes Signet 2734-2736 ph/orp Electrodes Compatible with Signet 8900/9900 Instruments Features Patented reference design for exceptional performance * Mounts in Signet standard fittings from DN15 to DN100 (½

More information

Signet 3719 ph/orp Wet-Tap Assembly

Signet 3719 ph/orp Wet-Tap Assembly Signet 3719 ph/p Wet-Tap Assembly Features Electrode removal without process shutdown Space saving 45 mm (1.75 in.) short-stroke design Sealed pneumatic dampening for smooth and safe operation SafeLoc

More information

Signet 2760 DryLoc ph/orp Preamplifiers & Connectors

Signet 2760 DryLoc ph/orp Preamplifiers & Connectors Signet 2760 DryLoc ph/orp Preamplifiers & Connectors Features In-line integral mount and submersible installation versions Automatic temperature compensation Auto configuration for ph or ORP operation

More information

Signet 3719 ph/orp Wet-Tap

Signet 3719 ph/orp Wet-Tap Signet 3719 ph/orp Wet-Tap *3-3719.090* 3-3719.090 Rev H 09/07 English Do not exceed maximum temperature/pressure specifications. Wear safety goggles or face shield during installation/service. Do not

More information

* * Rev. 9 01/18 Product Manual

* * Rev. 9 01/18 Product Manual English Signet 2760 DryLoc ph/orp Preamplifier *3-2760.090* 3-2760.090 Rev. 9 01/18 Product Manual Description The Signet 2760 ph/orp Preamplifiers with DryLoc connectors are part of Signet's growing line

More information

SIGNET 2750 ph/orp Sensor ENGLISH

SIGNET 2750 ph/orp Sensor ENGLISH ENGLISH 3-2750.090 B-8/01 English SAFETY INSTRUCTIONS FOR IN-LINE ELECTRODE INSTALLATION 1. Do not remove from pressurized lines. 2. Do not exceed maximum temperature/pressure specifications. 3. Wear safety

More information

Signet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems with PVDF Sensor

Signet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems with PVDF Sensor Signet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems with PVDF Sensor Features Test certificate supplied with all sensors Universal Mount Custom cell constant programmed into the

More information

Signet 2760 DryLoc ph/orp Preamplifier

Signet 2760 DryLoc ph/orp Preamplifier Signet 2760 DryLoc ph/orp Preamplifier *3-2760.090* 3-2760.090 Rev. H 05/11 English English SAFETY INSTRUCTIONS 1. Depressurize and vent system prior to installation or removal. 2. Confi rm chemical compatibility

More information

SIGNET 3719 ph/orp Wet-Tap

SIGNET 3719 ph/orp Wet-Tap ENGLISH 3-3719.090 B-6/02 English Do not exceed maximum temperature/pressure specifications. Wear safety goggles or face shield during installation/service. Do not attempt to disassemble the retraction

More information

SIGNET 2760 DryLoc ph/orp Preamplifier

SIGNET 2760 DryLoc ph/orp Preamplifier SIGNET 2760 DryLoc ph/orp Preamplifier 3-2760.090 3-2760.090 (A-3/04) English SAFETY INSTRUCTIONS 1. Depressurize and vent system prior to installation or removal. 2. Confirm chemical compatibility before

More information

Signet Conductivity/Resistivity Electrodes

Signet Conductivity/Resistivity Electrodes Signet 2818-2823 Conductivity/Resistivity Electrodes 2818 2819 2820 2821 2822 2823 Sanitary Features Standard process connections - Polypro - SS on 10 and 20 cell - Tri-clamp 1-1½ in., 2 - Opt. ½ in. NPT

More information

Signet 2551 Magmeter Flow Sensor

Signet 2551 Magmeter Flow Sensor Signet 2551 Magmeter Flow Sensor Available in a variety of wetted materials and ideal for pipe sizes up to DN900 (36 in.) Features Test certificate included for -X0, -X1 Patented Magmeter technology No

More information

Signet Conductivity/Resistivity Electrodes

Signet Conductivity/Resistivity Electrodes Signet 2818-2823 Conductivity/Resistivity Electrodes 2818 2819 2820 2821 2822 2823 Sanitary Features Standard process connections - Polypro - SS on 10 and 20 cell - Tri-clamp 1-1½ in., 2 in. - Opt. ½ in.

More information

Models 396/396P/396R. Retraction/Submersion/Insertion ph/orp Sensor

Models 396/396P/396R. Retraction/Submersion/Insertion ph/orp Sensor Models 396/396P/396R Product Data Sheet PDS 71-TUpH September 1999 Retraction/Submersion/Insertion ph/orp Sensor MINIMUM SENSOR MAINTENANCE due to patented TUpH reference technology 1 which ensures steady

More information

Signet V(D) to V(D) PVDF Conductivity Electrodes

Signet V(D) to V(D) PVDF Conductivity Electrodes Signet 2839-1V(D) to 2842-1V(D) PVDF Conductivity Electrodes Features ± 2% accuracy - Custom calibration certificate provided Dual-threaded Compact electrode length for easy in-line installation in small

More information

General Purpose ph/orp Sensors

General Purpose ph/orp Sensors Product Data Sheet PDS 71-3900/rev. B December 2010 Models 3900 and 3900VP General Purpose ph/orp Sensors EXTENDED SENSOR LIFE provided by double junction reference. ENHANCED PERFORMANCE AND INCREASED

More information

NEW QUICK CABLE-TO-SENSOR RELEASE,

NEW QUICK CABLE-TO-SENSOR RELEASE, Models 399 and 399VP Product Data Sheet PDS 71-399 October 2000 ph/orp Sensors NEW OPTIONS to meet a variety of application requirements, including: * Low ionic strength water * Processes with hydrofluoric

More information

General Purpose ph/orp Sensors

General Purpose ph/orp Sensors General Purpose ph/orp Sensors Product Data Sheet LIQ_PDS_3900 September 2013 General Purpose ph/orp Sensors SMART preamplifier-stores calibration and other data. Extended sensor life provided by double

More information

Signet 515 Rotor-X Paddlewheel Flow Sensors

Signet 515 Rotor-X Paddlewheel Flow Sensors Signet 515 Rotor-X Paddlewheel Flow Sensors Features Operating range 0.3 to 6 m/s (1 to 20 ft/s) Wide turndown ratio of 20:1 Highly repeatable output Simple, economical design Installs into pipe sizes

More information

TUpH Retraction/Submersion/Insertion ph/orp Sensors

TUpH Retraction/Submersion/Insertion ph/orp Sensors Product Data Sheet PDS 71-TUpHVP/rev.B June 2003 Models 396VP, 396RVP, 398VP, & 398RVP TUpH Retraction/Submersion/Insertion ph/orp Sensors SILCORE 3 TECHNOLOGY PROVIDES INCREASED SENSOR LIFE when used

More information

Signet 2536 Rotor-X Paddlewheel Flow Sensors

Signet 2536 Rotor-X Paddlewheel Flow Sensors Signet 2536 Rotor-X Paddlewheel Flow s Features Operating range 0.1 to 6 m/s (0.3 to 20 ft/s) Wide turndown ratio of 66:1 Open-collector output Highly repeatable output Simple, economical design PVC (gray

More information

Digital ph transmitter

Digital ph transmitter Digital ph transmitter Compact, remote versions for DN 15 to 200 Fully programmable ph transmitter functions for all kinds of ph-measurement tasks Large range of process connections with various fittings

More information

Digital ph transmitter

Digital ph transmitter Digital ph transmitter Compact, remote versions for DN 15 to 200 Fully programmable ph transmitter functions for all kinds of ph-measurement tasks Large range of process connections with various fittings

More information

Signet ph/orp Transmitter

Signet ph/orp Transmitter Signet 87501 ph/orp English *38750.0901* 38750.0901 Rev. F 3/06 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury.

More information

Signet 515 Rotor-X Paddlewheel Flow Sensors

Signet 515 Rotor-X Paddlewheel Flow Sensors Signet 515 Rotor-X Paddlewheel Flow Sensors Features Operating range 0.3 to 6 m/s (1 to 20 ft/s) Wide turndown ratio of 20:1 Highly repeatable output Simple, economical design Installs into pipe sizes

More information

Signet Measurement and Instrumentation

Signet Measurement and Instrumentation F Piping Systems Signet Measurement and Instrumentation Price List effective January 1, 2015 Conveyance Pipe, Fittings, Joining Technology // PVC/CPVC // PPro-Seal PP // PROEF PP // SYEF PVDF // Contain-It

More information

Insertion/Submersion Flow Through Sensor

Insertion/Submersion Flow Through Sensor Product Data Sheet PDS 71-381/rev.B September 2004 Model 381 ph/orp Insertion/Submersion Flow Through Sensor ADVANCED ON-LINE SENSOR DIAGNOSTICS 1 (Model 381+ only), for use with the Models 54e ph/orp

More information

Low Profile Insertion Vortex

Low Profile Insertion Vortex Low Profile Insertion Vortex Product Features The same insertion meter can measure Steam, Gases or Liquids. Standardize on an insertion bar that can measure line sizes 2 24 Heavy Duty & Maintenance Free

More information

* * Signet 2450 Pressure Sensor. Product Manual. English. Description. Dimensions Rev /18

* * Signet 2450 Pressure Sensor. Product Manual. English. Description. Dimensions Rev /18 English Signet 2450 Pressure Sensor *32450.0901* 32450.0901 Rev. 13 03/18 Product Manual Description The 2450 Pressure Sensor has a onepiece injection molded PVDF body and ceramic diaphragm for superior

More information

ph/orp Sensor Model 399 ph/orp

ph/orp Sensor Model 399 ph/orp Model 399 ph/orp Product Data Sheet PDS 71-399 September 1999 ph/orp Sensor DOUBLE JUNCTION REFERENCE CELL provides longer sensor life in process solutions containing poisoning ions. ONE-PIECE CONSTRUCTION

More information

TUpH 396, 396VP, 396P, 396PVP, 396R, 396RVP

TUpH 396, 396VP, 396P, 396PVP, 396R, 396RVP TUpH 396, 396VP, 396P, 396PVP, 396R, 396RVP Product Data Sheet LIQ-PDS-396P-PVP-R-RVP April 2016 TUpH 396, 396VP, 396P, 396PVP, 396R, 396RVP Retraction/Submersion/Insertion ph/orp Sensors Smart enabled

More information

AP300 Series Combination ph/redox (ORP) Sensors. Measurement made easy. A reliable economic solution for a wide range of applications

AP300 Series Combination ph/redox (ORP) Sensors. Measurement made easy. A reliable economic solution for a wide range of applications Data sheet DS/AP00 EN Rev. F AP00 Series Measurement made easy A reliable economic solution for a wide range of applications Long life large PTFE junction provides resistance to fouling double junction

More information

Model Q45H/ Residual Chlorine Monitor...

Model Q45H/ Residual Chlorine Monitor... Model Q45H/62-63 Residual Chlorine Monitor... ATI s Model Q45H is designed for on-line monitoring and control of chlorination systems. It is available in two versions: a free chlorine monitor for drinking

More information

SIGNET 7002 Vortex Flow Sensor ENGLISH

SIGNET 7002 Vortex Flow Sensor ENGLISH SIGNET 7002 Vortex Flow Sensor ENGLISH 3-7002.090 C-7/02 English SAFETY INSTRUCTIONS 1. Do not remove from pressurized lines. 2. Never install sensor without O-Rings. 3. Confirm chemical compatibility

More information

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.I December 2008

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.I December 2008 Product Data Sheet PDS 71-400/rev.I December 2008 Model 400 and 400VP Series ENDURANCE General Purpose Conductivity Sensors INITIAL CALIBRATION NOT REQUIRED. Pre-determined cell constant ensures out-of-the

More information

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.G February 2006

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.G February 2006 Product Data Sheet PDS 71-400/rev.G February 2006 Model 400 and 400VP Series ENDURANCE General Purpose Conductivity Sensors INITIAL CALIBRATION NOT REQUIRED. Pre-determined cell constant ensures out-of-the

More information

Encapsulated Differential ph and ORP Sensors (available in LCP, foreground, or Ryton body materials)

Encapsulated Differential ph and ORP Sensors (available in LCP, foreground, or Ryton body materials) Technology For Solutions Data Sheet LRE/102 Supersedes LRE/400 Encapsulated Differential ph and ORP Sensors (available in LCP, foreground, or Ryton body materials) Common Features Differential Electrode

More information

FLOWX3 F3.60M.S Insertion Magmeter

FLOWX3 F3.60M.S Insertion Magmeter FLOWX3 F3.60M.S Insertion Magmeter The FLOWX3 F3.60M.S Insertion Magmeters are suitable to measure flowrate in both metal and thermoplastic pipelines. No moving mechanical parts and the high quality materials

More information

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.K February 2013

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.K February 2013 Product Data Sheet PDS 71-400/rev.K February 2013 Model 400 and 400VP Series ENDURANCE General Purpose Conductivity Sensors INITIAL CALIBRATION NOT REQUIRED. Factory-measured cell constant ensures out-of-the-box

More information

2100 Turbine Flow Sensor

2100 Turbine Flow Sensor 200 Turbine Flow Sensor Description Engineered specifically for small pipe diameter applications, the Signet 200 Turbine Flow Sensor provides accurate readings in two flow ranges: 0.3 to 3.8 lpm and 3

More information

Measurement & Instrumentation 2005 Product Catalog on CD. Creating Quality by Connecting Technology to Life. Click on image to begin.

Measurement & Instrumentation 2005 Product Catalog on CD. Creating Quality by Connecting Technology to Life. Click on image to begin. Measurement & Instrumentation 2005 Product Catalog on CD Creating Quality by Connecting Technology to Life Click on image to begin. Main Contents Measurement & Instrumentation 2005 Product Catalog Flow

More information

Accessories Guide ph/orp/conductivity Sensors

Accessories Guide ph/orp/conductivity Sensors Jet Cleaners and Scrubber Accessories Isolation Ball Valves Assemblies Compression Fittings and Sheath Sets High Pressure (2500 PSIG) Sensor Housings In-line Flow Cells Nut Lock Union Style Adapters Sensor

More information

Dissolved Oxygen, ph, and Conductivity

Dissolved Oxygen, ph, and Conductivity Product Data Sheet PDS 71-steam/rev.E February 2005 Steam Sterilizable Solutions Dissolved Oxygen, ph, and Conductivity STEAM STERILIZABLE AND AUTOCLAVABLE DISSOLVED OXY- GEN, ph, AND CONDUCTIVITY SENSORS:

More information

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.J January 2011

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.J January 2011 Product Data Sheet PDS 71-400/rev.J January 2011 Model 400 and 400VP Series ENDURANCE General Purpose Conductivity Sensors INITIAL CALIBRATION NOT REQUIRED. Pre-determined cell constant ensures out-of-the

More information

Model FVP General Specification. Flanged Vortex Plate. Product Features

Model FVP General Specification. Flanged Vortex Plate. Product Features Flanged Vortex Plate Product Features Our Inline meters can measure Steam, Gases or Liquids. Measures two times lower than any other Vortex Meter. Heavy Duty & Maintenance Free Design C&C Machined from

More information

ProMinent. ProMinent D4a Metering Pumps with built-in proportional controllers

ProMinent. ProMinent D4a Metering Pumps with built-in proportional controllers D4a Metering Pumps with built-in proportional controllers A series of solenoid-driven metering pumps with built-in ph controller, oxidation-reduction potential (Redox) controller or chlorine controller.

More information

Signet Measurement and Instrumentation

Signet Measurement and Instrumentation F Piping Systems Signet Measurement and Instrumentation Price List effective January 1, 2018 NEW! DryLoc ph/orp Smart Sensor Electronics See page 37 for new lower pricing on Portaflow Ultrasonic Flow Meters!

More information

FLS F6.60 MAGMETER FLOW SENSOR INSERTION FLOW SENSORS APPLICATIONS MAIN FEATURES

FLS F6.60 MAGMETER FLOW SENSOR INSERTION FLOW SENSORS APPLICATIONS MAIN FEATURES FLS F6.60 MAGMETER FLOW SENSOR The new F6.60 and F6.63 are flow meters without moving mechanical parts which can be applied for the measurement of dirty liquids so long as they are conductive and homogeneous.

More information

MEASUREMENT AND INSTRUMENTATION FLS

MEASUREMENT AND INSTRUMENTATION FLS MEASUREMENT AND INSTRUMENTATION FLS The FLS Measurement and Instrumentation line consists of a comprehensive range of Flow, ph, ORP, Conductivity Sensors, Monitors and Transmitters. INDEX SYSTEM SELECTION

More information

Conductivity meter. PLC Solenoid valve. Type Type On/Off Diaphragm valve. Valve islands

Conductivity meter. PLC Solenoid valve. Type Type On/Off Diaphragm valve. Valve islands Conductivity meter Configurable outputs: two transistor and single or dual analog 4... 20 ma Removable backlighted display Universal process connection Type can be combined with... Three cell constants

More information

Hot Tap Insertion Vortex

Hot Tap Insertion Vortex Hot Tap Insertion Vortex Product Features The same insertion meter can measure Steam, Gases or Liquids. Standardize on an insertion bar that can measure line sizes 2 48 Heavy Duty & Maintenance Free Design

More information

SIGNET Vortex Flow Sensors ENGLISH

SIGNET Vortex Flow Sensors ENGLISH DN X DN X DN X DN X DN X DN X DN X SIGNET Vortex Flow Sensors ENGLISH 37000.090 C12/00 English 1. Mounting Location... 1 2. Installation... 1 3. Wiring Preparation... 2 4. Wiring Options Frequency Output

More information

Automation Made Easy 2013 Signet Measurement and Control Product Catalog

Automation Made Easy 2013 Signet Measurement and Control Product Catalog Multi-Parameter Chlorine Dissolved Oxygen Turbidity Flow ph/orp Conductivity/Resistivity Temperature Pressure Level Automation Made Easy 2013 Signet Measurement and Control Product Catalog Automation Made

More information

Analytical Instruments Two-Electrode Conductivity Sensors

Analytical Instruments Two-Electrode Conductivity Sensors Data Sheet Analytical Instruments Two-Electrode Conductivity Sensors Model TB2 Superior accuracy in low conductivity measurement ranges. Measurement ranges from 0 to 199.9 µs/cm to 0 to 19.99 ms/cm. Resolution

More information

Vortex Plate. Model VP General Specification. Product Features

Vortex Plate. Model VP General Specification. Product Features Vortex Plate Product Features Our Inline meters can measure Steam, Gases or Liquids. Heavy Duty & Maintenance Free Design C&C Machined from one piece of solid stainless steel Absolutely NO o-rings or seals

More information

Chapter Page. 1 Introduction Description 1

Chapter Page. 1 Introduction Description 1 Chapter Page 1 Introduction 1 1.1 Description 1 Table of Contents 2 Calibration 3 2.1 Wet Calibration 3 2.2 Calibration Procedure 4 2.3 Installing Optional Display Board 5 2.4 Display Board Range Adjustment

More information

Measurement and Instrumentation

Measurement and Instrumentation 15 Measurement and Instrumentation Use the postcard included in this handbook or call (800) 854-4090 to order the complete Instrumentation Catalog or visit www.gfsignet.com for detailed product information.

More information

Foxboro Dew Point Measurement System Model 2761 Mechanical DEWCEL Element Model 2781 Electrical DEWCEL Element

Foxboro Dew Point Measurement System Model 2761 Mechanical DEWCEL Element Model 2781 Electrical DEWCEL Element Product Specifications Foxboro Dew Point Measurement System Model 2761 Mechanical DEWCEL Element Model 2781 Electrical DEWCEL Element PSS 1-5A1 A MODEL 2761 MODEL 2781 The Foxboro Dew Point Measurement

More information

Combination ph/redox (ORP) Sensors

Combination ph/redox (ORP) Sensors Data Sheet Combination ph/redox (ORP) s Series AP00 User-customizable for Insertion, Flow-through, Immersion, Hot-tap Retractor ideal for Original Equipment Manufacturers and general applications Economical

More information

Hydro-Flow 2200 Fixed Insertion Vortex Flow Meter

Hydro-Flow 2200 Fixed Insertion Vortex Flow Meter A trademark of Spirax Sarco, Inc. Hydro-Flow 2200 Fixed Insertion Vortex Flow Meter Description The Hydro-Flow Model 2200 fixed insertion vortex flow meter was designed specifically for water flow measurement,

More information

Inductive conductivity meter

Inductive conductivity meter Inductive conductivity meter CIP version Type 8228 can be combined with... Standard version Perfect for concentrated liquids and wide conductivity range Pre-parameterized versions available for direct

More information

Combination ph/redox (ORP) Sensors

Combination ph/redox (ORP) Sensors Data Sheet SS/AP00_ Combination ph/redox (ORP) s AP00 Series User-customizable for Insertion, Flow-through, Immersion and Hot-tap Retractor ideal for OEMs (Original Equipment Manufacturers) and general

More information

Signet 7000/7001 Vortex Flow Sensors * *

Signet 7000/7001 Vortex Flow Sensors * * DN X DN X DN X DN X DN X DN X DN X Signet 7000/7001 Vortex Flow Sensors *3-7000.090* 3-7000.090 Rev. F 10/05 English English 1. Mounting Location... 1 2. Installation... 1 3. Wiring Preparation... 2 4.

More information

ABB MEASUREMENT & ANALYTICS DATA SHEET. TBX5 ph, Redox (ORP) sensors with diagnostics

ABB MEASUREMENT & ANALYTICS DATA SHEET. TBX5 ph, Redox (ORP) sensors with diagnostics BB MESUREMENT & NLYTICS DT SHEET TBX ph, Redox (ORP) sensors with diagnostics Measurement made easy The most durable ph / Redox (ORP) sensors in the world Next Step Solid State reference eliminates poisoning,

More information

ISTEC MAGNETIC METERS

ISTEC MAGNETIC METERS ISTEC MAGNETIC METERS MEASURE ANY CONDUCTIVE LIQUIDS OR SLURRIES (EVEN ABRASIVE OR CORROSIVE) WITH THE NEW MICROPROCESSOR-BASED MAGNETIC METER -- A QUALITY PRODUCT - SIMPLE - RELIABLE - AT AN AFFORDABLE

More information

Time Electronics. Calibration, Test and Measurement. Portable Process and Pressure Calibration Instruments

Time Electronics. Calibration, Test and Measurement. Portable Process and Pressure Calibration Instruments Time Electronics Calibration, Test and Measurement Portable Process and Pressure Calibration Instruments Calibrators Simulators Sources Pumps Gauges www.timeelectronics.com Loop & Temperature Calibration

More information

Optidew Vision Optical Dew-Point Meter

Optidew Vision Optical Dew-Point Meter Optidew Vision Optical Dew-Point Meter Chilled Mirror Instruments A precision hygrometer, combining drift free measurement with the flexibility of a remote sensor. Ideal for laboratory and industrial measurements,

More information

Liquid Conductivity Two & Four Electrode Sensors

Liquid Conductivity Two & Four Electrode Sensors Industrial Process Control & Monitoring Rugged Two Electrode Conductivity Sensors Unique Four Electrode Conductivity Sensors Versatile Installation Options (Threaded, Quick Change, Retractable) Specialized

More information

F-1500 SERIES INSERTION TURBINE FLOW METER

F-1500 SERIES INSERTION TURBINE FLOW METER F-1500 SERIES INSERTION TURBINE FLOW METER APPLICATIONS Saturated steam Hot water to 450 F (232 C) standard 850 F (454 C) optional Applications with optional pressure sensor Superheated steam to 450 F

More information

flow x3 flow monitoring

flow x3 flow monitoring flow x3 flow monitoring The FlowX3 System includes a complete range of paddle wheel flow sensors, instruments and sensor installation fittings. Also included are insertion type electromagnetic flow transmitters.

More information

F-2700 SERIES INSERTION VORTEX FLOW METER

F-2700 SERIES INSERTION VORTEX FLOW METER F-2700 SERIES INSERTION VORTEX FLOW METER APPLICATIONS Saturated steam Hot water to 500 F (260 C) standard 750 F (400 C) optional Applications with optional pressure sensor Superheated steam to 500 F (260

More information

Paddle-wheel flow controller for On/Off control

Paddle-wheel flow controller for On/Off control Paddle-wheel flow controller for On/Off control Type 803 can be combined with... Indication, monitoring, transmitting and On/Off control in one device Programmable s (transistor or relay) Automatic-calibration:

More information

Type 147. Electrically Actuated Lug Butterfly Valve

Type 147. Electrically Actuated Lug Butterfly Valve GF Piping Systems Electrically Actuated Lug Butterfly Valve Type 147 General Size: 2 12 Outer Body: Glass-filled PP Material: PVC, CPVC, PROGEF Standard PP, ABS, SYGEF Standard PVDF Seals: EPDM, FPM, PTFE/FPM

More information

TURCK Inc Campus Drive Minneapolis, MN Application Support: Fax: (763) M2

TURCK Inc Campus Drive Minneapolis, MN Application Support: Fax: (763) M2 Process INSTRUMENTATION TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-553-0016 Fax: (763) 553-0708 www.turck.com M2 TURCK Process Instrumentation Pressure Selection Guide

More information

Inductive conductivity meter

Inductive conductivity meter Inductive conductivity meter Type 8228 can be combined with... Configurable outputs: up to 2 transistor and up to 2 analog 4... 20 ma outputs Removable backlighted display Simulation of process values

More information

Conductivity. Inductive Conductivity Sensors. Features and Benefits DATA SHEET. Wide Measuring Range. Low-maintenance Design. Complete Digital System

Conductivity. Inductive Conductivity Sensors. Features and Benefits DATA SHEET. Wide Measuring Range. Low-maintenance Design. Complete Digital System DATA SHEET Inductive Conductivity Sensors Features and Benefits Wide Measuring Range Hach s Inductive Conductivity Sensors measure 200 up to 2,000,000 microsiemens/cm. A built-in Pt 1000 RTD compensates

More information

BYV Series Butterfly Valve Product Guide FLOW CONTROL

BYV Series Butterfly Valve Product Guide FLOW CONTROL BYV Series Butterfly Valve Product Guide FLOW CONTROL 17 Q U A L I T Y S E R V I C E I N T E G R I T Y 1 OVERVIEW Engineered Hand Lever Design for Enhanced Strength and UV Performance Ergonomic Grip and

More information

* * Rev. F 03/16 Operating Instructions

* * Rev. F 03/16 Operating Instructions English Signet 2552 Metal Magmeter *3-2552.090* 3-2552.090 Rev. F 03/16 Operating Instructions 3-2552-2 3-2552-3 Description The Signet 2552 Metal Magmeter from Georg Fischer features all-stainless steel

More information

Dissolved Oxygen Measurement System with Air Blast Cleaner

Dissolved Oxygen Measurement System with Air Blast Cleaner Product Data Sheet PDS 71-DO-03/04/rev.D August 2004 MODEL DO -03/-04 Dissolved Oxygen Measurement System with Air Blast Cleaner COMPLETE SYSTEM INCLUDES sensor, analyzer, sensor washer head, mounting

More information

HUMIDITY / TEMPERATURE TRANSMITTER

HUMIDITY / TEMPERATURE TRANSMITTER HUMIDITY / TEMPERATURE TRANSMITTER SEM161, SEM16 CONFIGURATION USING USB PORT POWERED CONFIGURATOR HUMIDITY, TEMPERATURE, DEW POINT MEASUREMENT INTERCHANGEABLE DIGITAL SENSOR HIGH ACCURACY AND STABILITY

More information

* * Rev M 10/14 Operating Instructions

* * Rev M 10/14 Operating Instructions English Signet 55 Blind Magmeter *-55.090* -55.090 Rev M 0/ Operating Instructions Description The Signet 55 Magmeter is an insertion-style magnetic flow sensor. The patented sensor design is available

More information

JUMO ecoline Ci Inductive conductivity and temperature sensor for general water engineering

JUMO ecoline Ci Inductive conductivity and temperature sensor for general water engineering Data Sheet 22943 Page 1/9 JUMO ecoline Ci Inductive conductivity and temperature sensor for general water engineering Brief description The sensor detects the electrolytic conductivity of a process liquid.

More information

Paddle-wheel flow controller for On/Off control

Paddle-wheel flow controller for On/Off control Paddle-wheel flow controller for On/Off control Type 8032 can be combined with... Indication, monitoring, transmitting and On/Off control in one device Programmable outputs (transistor or relay) Automatic-calibration:

More information

display on the wall or in a panel away from the inline sensor SE30 for easy meter reading.

display on the wall or in a panel away from the inline sensor SE30 for easy meter reading. Analogue Flow Rate Indicator, DN 15...; PN 1...16 Advantages / Benefits Reduced costs of ownership up to 6% Economic integration in pipe systems without any additional piping Shows flow rate with a large

More information

Product Specifications

Product Specifications PE 100 Metric Piping System Specifications 1. Scope This specification covers requirements for the +GF+ Georg Fischer (later named only +GF+) PE 100 Piping System intended for a wide range of applications

More information

GF Signet. Measurement & Control Sensors. Signet Price List 1st Aug 2011 Rev 0.0

GF Signet. Measurement & Control Sensors. Signet Price List 1st Aug 2011 Rev 0.0 GF Signet Measurement & Control Sensors Sensors and Transmitters: Flow ph Conductivity ORP Level Pressure Temperature Turbidity Chlorine Installation fittings Power supplies Calibration solutions Accessories

More information

JUMO ecoline Ci Inductive conductivity and temperature sensor for general water engineering

JUMO ecoline Ci Inductive conductivity and temperature sensor for general water engineering Data Sheet 22943 Page 1/9 JUMO ecoline Ci Inductive conductivity and temperature sensor for general water engineering Brief description The sensor detects the electrolytic conductivity of a process liquid.

More information

Corrosion Resistant and Ultra-Pure Rotameters for Accurate Measurement of Liquids and Gases

Corrosion Resistant and Ultra-Pure Rotameters for Accurate Measurement of Liquids and Gases Corrosion Resistant and Ultra-Pure Rotameters for Accurate Measurement of Liquids and Gases Rotameters Markets/Applications George Fischer rotameters are ideally suited for a multitude of corrosive and

More information

Index Flow Sensors FLOWX3 F3.00 Paddlewheel Flow Sensor page 2 FLOWX3 F111 Hot Tap Flow Sensor page 18 FLOWX3 F3.60M Insertion Magmeter page 24 FLOWX3

Index Flow Sensors FLOWX3 F3.00 Paddlewheel Flow Sensor page 2 FLOWX3 F111 Hot Tap Flow Sensor page 18 FLOWX3 F3.60M Insertion Magmeter page 24 FLOWX3 09-10 LEFLSFX10 Index Flow Sensors FLOWX3 F3.00 Paddlewheel Flow Sensor page 2 FLOWX3 F111 Hot Tap Flow Sensor page 18 FLOWX3 F3.60M Insertion Magmeter page 24 FLOWX3 F9.60M Insertion Magmeter with display

More information

General Specifications

General Specifications General Specifications Model PH20 and FU20 ph/redox and Temperature sensor The PH20 is nicknamed "Tempress" because of the patented compensation for changes in the process temperature and pressure. This

More information

DISSOLVED OXYGEN MEASUREMENT

DISSOLVED OXYGEN MEASUREMENT DISSOLVED OXYGEN MEASUREMENT ACTEON 2030 TRANSMITTER Potentiometric measurement technology Robust, watertight, easy to install, Widescreen graphic display: instant measurements, trend line, relay state,

More information

MEASUREMENT SOLUTIONS FOR THE WATER & WASTEWATER INDUSTRY

MEASUREMENT SOLUTIONS FOR THE WATER & WASTEWATER INDUSTRY MEASUREMENT SOLUTIONS FOR THE WATER & WASTEWATER INDUSTRY MUNICIPAL AND INDUSTRIAL WATER & WASTEWATER PROCESSING NOSHOK provides pressure, level and temperature measurement solutions, along with diaphragm

More information

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727) F-1500 SERIES INSERTION TURBINE FLOW METER Insertion turbine flow meters are ideal for use in larger steam lines where downsizing the line size to improve flow measurement is not desirable. In these applications,

More information

G2 Industrial Grade Meters

G2 Industrial Grade Meters G2 Industrial Grade Meters The unique modular approach of the Industrial Grade Meter line allows you to section 2: g2 industrial grade meters design a meter to match your specific application. Turbine

More information

F-2700 SERIES INSERTION VORTEX FLOW METER

F-2700 SERIES INSERTION VORTEX FLOW METER F-2700 SERIES INSERTION VORTEX FLOW METER CALIBRATION Every ONICON flow meter is wet calibrated in a flow laboratory against standards that are directly traceable to N.I.S.T. A certificate of calibration

More information

OPERATING INSTRUCTION MANUAL

OPERATING INSTRUCTION MANUAL OPERATING INSTRUCTION MANUAL MODEL P/R65 DIFFERENTIAL 2-WIRE (4-20 ma) ph & ORP PROBES N116-139 REV. 0 Aquametrix, by Water Analytics Inc. 100 School Street Andover, MA 01810 Tel: (978) 749-9949 Toll Free:

More information