1 SIGNET 2760 DryLoc ph/orp Preamplifier (A-3/04) English SAFETY INSTRUCTIONS 1. Depressurize and vent system prior to installation or removal. 2. Confirm chemical compatibility before use. 3. Do not exceed maximum temperature/pressure specifications. 4. Wear safety goggles or faceshield during installation/service. 5. Do not alter product construction. 6. When using chemicals or solvents care should be taken and appropriate eye, face, hand, body, and/or respiratory protection should be used. Description The +GF+ SIGNET 2760 ph/orp Preamplifiers with DryLoc connectors are part of George Fischer Signet's growing arsenal of sensors for industrial fluid measurement and control. The and -2 Preampliers connects to three different families of ph and ORP electrodes to provide a stable and relaible signal input to traditional +GF+ SIGNET instruments. The and -4 models use the same package to link the same electrodes to third-party equipment that read a traditional millivolt signal for ph measurement without temperature compensation or amplification. Technical Data General Compatible Electrodes: +GF+ SIGNET DryLoc ph and ORP Electrodes Response Time (includes response time of electrodes): ph: <6 s for 95% of change ORP: application dependent Temperature, t: w/2764, 2774 series: 20 s w/2754 : 140 s w/ s Electrical (2760-1, -2 Preamplifiers) Accuracy: ±2 25 C (77 F) Input Impedance, Z: >10 11 Ω Supply Voltage: 6 to 10 VDC Dimensions mm (1.25 in.) 70.1 mm (2.76 in.) 89.4 mm (3.52 in.) Environmental Enclosure Rating: NEMA 6P/IP68 with electrode and watertight conduit and/or extension pipe connected Wetted Materials: CPVC Cable: Maximum cable: Shipping Weight: 4.6m/15 ft., 3-cond shielded, 22AWG 122 m (400 ft.) 0.64 kg (1.41 lb) 56.6mm (2.23 in.) Operating Temperature: Storage Temperature: Relative Humidity: 0 C to 85 C (32 F to 185 F) -20 C to 85 C (-4 F to 185 F) 0 to 95%, non-condensing (without electrode connected) Standards and Approvals CE Manufactured under ISO 9001:2000 for Quality and ISO 14001:1996 for Environmental Management Bottom View showing DryLoc connectors
2 In-line Assembly and Installation Select a location in the pipe that can accomodate the height of the 2760 and electrode assembly. When fully assembled the 2760 and electrode assembly measures approximately 18 cm (7 in.) from the process threads to the top of the preamplifier. 1. For Differential electrodes ( ): Install a standard 1 in. NPT pipe tee into the process line. For Combination electrodes ( ): Install a standard 3/ 4 in. NPT pipe tee into the process line. Note: Combination DryLoc electrodes cannot be installed in-line with the Remove the retaining nut from the base of the 2760 and slide it over the electrode from the bottom. 3. Thread the electrode into the pipe tee. Use appropriate sealant (example: Teflon tape) to create a water-tight connection. 4. Connect the 2760 DryLoc connector onto the top of the electrode and hand-tighten the retaining nut onto the threads to secure the assembly. 3/4 in. Conduit (customer supplied) 2760 Preamplifier ph or ORP Electrode 5. Use 3/4 in. rigid or flexible conduit to protect the cable from damage. 6. If the cable will be extended beyond the standard 15 ft. supplied with the 2760, use a junction box to terminate the wires. Note: Do not extend the 2760 cable more than 120 m (400 ft.). Fitting 2764 Differential DryLoc electrodes require a 1 in. NPT process connection Combination DryLoc Electrodes require a 3/4 in. NPT process connection. Installation Dimensions 107 mm (4.2 in.) Differential Electrodes Combination Electrodes Combination Electrodes 35.6mm (1.4 in.) 38.6mm (1.52 in.) 35.5mm (1.4 in.) 38.6mm (1.52 in.) 27 mm/ 1.0 in. 27 mm/ 1.0 in. 178 mm (7 in.) 32.5mm (1.28 in.) 29.2mm (1.15 in.) 30.5 mm/ 1.2 in. 97 mm/ 3.8 in mm/ 1.2 in. 104 mm/ 4.1 in mm (5.27 in.) 1 in. NPT 128.3mm (5.05 in.) 3/4 in. NPT 65 mm/ 2.6 in. 86 mm/ 3.4 in. 65 mm/ 2.6 in. 86 mm/ 3.4 in. 28.7mm (1.13 in.) 22.8mm (0.9 in.) 25.4mm (1.0 in.) 22.1mm (0.87 in.) 23 mm/ 0.9 in. 23 mm/ 0.9 in. SIGNET 2 of DryLoc ph/orp Preamplifier
3 2760 Submersible Sensor Assembly and Installation Any combination of 2760 and electrode can be installed in a tank or vessel if conditions are within pressure and temperature specifications. The 2760 is able to withstand fluid temperatures up to 85 C, but the maximum tolerance of the electrodes varies. Check the specifications of each component before installation. 1. Insert any DryLoc electrode into base of the 2760 and turn until keyed contacts are seated. 2. Thread retaining cap over electrode and hand-tighten onto A light coat of a non-petroleum based lubricant on the O-ring will ease the installation. Keep the DryLoc electrical interconnection between electrode and preamplifier dry and clean at all times. 3. Attach 3 /4 in. watertight pipe to the top of the Secure the threaded connection to prevent any leakage. For additional defense against possible accumulation of condensation at the back seal area of the 2760, fill the lower 3-4 inches ( mm) of conduit or extension pipe with a flexible sealant such as silicone mm/ 8.2 in. Fill with mm (3 to 4 in.) of sealant 55 mm/ 2.16 in. Use standard installation hardware to connect the submersible 2760 directly to external equipment. OR The NPT Mount Junction box connects to 3 /4 in. pipe or conduit and provides convenient wiring termination. OR The Universal Mount junction box mounts flat onto a wall or can be strapped to a post or pipe. 106 mm/ 4.2 in. 94 mm/ 3.7 in. 94 mm/ 3.7 in. 107 mm/ 4.2 in. 1/2 in. NPT threads Fill with 3 to 4 in. of sealant Fill with 3 to 4 in. of sealant Fill with 3 to 4 in. of sealant 2760 DryLoc ph/orp Preamplifier SIGNET 3 of 8
4 Wiring to +GF+ SIGNET Instruments Any of these electrodes can be connected to the +GF+ SIGNET ProPoint and ProcessPro ph instruments using the /-2 Preamplifier. Wiring diagrams illustrate the actual terminals on these products for convenience. Differential 1 in. Process conn Standard 3/4 in. Process conn Standard Flat DryLoc HF Standard Bulb DryLoc DI ph/orp Monitor mv Input Brown wire Iso. Gnd Blue wire T + Green wire T - White wire V + Red Wire V - Black wire Brown mv Blue Iso. Gnd Green T+ White T- Red V+ Black V ma ProcessPro ph/orp Transmitter Connect this terminal White (Temp) Green (Temp) Blue (Iso. Gnd) Brown (mv input) Shield Black (V-) Red (V+) to Earth GND to reduce electrical interference SIGNET 4 of DryLoc ph/orp Preamplifier
5 Wiring from 2760 DryLoc Preamplifier to Other Manufacturer's Equipment The /-2 Preamplifier can be connected to other manufacturer's instruments that can process the standard amplified mv signal for ph and also are compatible with one of the temperature compensation devices available (3KΩ, PT1000, or 300Ω). Refer to the manufacturer's manual for wiring details. Other products may use different terms to identify the function of each conductor. Differential ph Electrodes (3KΩ RTD) (3KΩ RTD) (PT1000 RTD) (PT1000 RTD) (300Ω RTD) (300Ω RTD) Differential ORP (Redox) Electrodes (10KΩ ID) (10KΩ ID) (PT1000 RTD) (PT1000 RTD) (300Ω RTD) (300Ω RTD) Combination ph Electrodes (3KΩ RTD) (3KΩ RTD) (PT1000 RTD) (PT1000 RTD) (PT1000 RTD) HF (PT1000 RTD) (PT1000 RTD) DI (PT1000 RTD) WT (PT1000 RTD) DryLoc Preamplifier Combination ORP (Redox) Electrodes (10KΩ ID) (10KΩ ID) (no Temp Comp) (no Temp Comp) (10KΩ ID) (10KΩ ID) WT (10KΩ ID) White (Temperature) Green (Temperature) Blue (mv Reference) Shield (Earth Ground) Black (V-) Red (V+) Brown (Active mv, ph/orp) Wiring from 2760 DryLoc Connectors to Other Manufacturer's Equipment The /4 Connectors can be used to interface other manufacturer's instruments to these +GF+ SIGNET DryLoc ph and ORP electrodes. The instrument must be able to process a standard mv signal from the ph or ORP electrode. Several different temperature devices are available. Refer to the manufacturer's manual for wiring details. Other products may use different terms to identify the function of each conductor. DryLoc Connector Combination ph Electrodes (3KΩ RTD) (3KΩ RTD) (PT1000 RTD) (PT1000 RTD) (PT1000 RTD) HF (PT1000 RTD) (PT1000 RTD) DI (PT1000 RTD) WT (PT1000 RTD) White RTD (Temperature) Green RTD (Temperature) Blue Solution Ground Shield Earth Ground Black Electrode Reference Red (Active mv, ph/orp) Brown (no connection) Combination ORP (Redox) Electrodes (10KΩ ID) (10KΩ ID) (no Temp Comp) (no Temp Comp) (10KΩ ID) (10KΩ ID) WT (10KΩ ID) To any instrument with internal amplifier and matching temp device DryLoc ph/orp Preamplifier SIGNET 5 of 8
6 Notes SIGNET 6 of DryLoc ph/orp Preamplifier
7 Notes 2760 DryLoc ph/orp Preamplifier SIGNET 7 of 8
8 Ordering Information Mfr. Part No. Code Description Preamplifier with 3/4 in. NPT threads and 4.6 m (15 ft.) cable Preamplifier with 3/4 in. ISO threads and 4.6 m (15 ft.) cable Connector with 4.6 m (15 ft.) cable and 3/4 in. NPT threads Connector with 4.6 m (15 ft.) cable and ISO 7/1R 3/4 threads Accessories and Replacement Parts Calibration Tools ph/orp System Tester (adapter cable sold separately) Adapter Cable for use w/2760 DryLoc Preamplifier ph Buffer Kit (1 each 4, 7, 10 ph buffer in powder form, makes 50 ml) Cable, 6 conductor, 24 AWG shielded Mounting Hardware Universal Mount Junction Box /4 in. NPT Mount Junction Box Liquid Tight Connector Kit, NPT (1 connector) Liquid Tight Connector Kit, PG13.5 (1 connector) Electrodes DryLoc ph Electrodes Combination ph Electrode, 3KΩ RTD, flat glass HF Combination ph Electrode, HF Resistsant, 3KΩ RTD, flat glass Combination ph Electrode, 3KΩ RTD, bulb glass DI Combination ph Electrode, DI Resistant, 3KΩ RTD, bulb glass Differential ph Electrode, 3KΩ RTD, 1 in. NPT process connection Differential ph Electrode, PT1000 RTD, 1 in. NPT process connection Differential ph Electrode, 300Ω RTD, 1 in. NPT process connection Differential ph Electrode, 3KΩ RTD, 1 in. NPT process connection Differential ph Electrode, PT1000 RTD, 1 in. NPT process connection Differential ph Electrode, 300Ω RTD, 1 in. NPT process connection Combo flat ph Electrode, 3KΩ RTD, 3/4 in. NPT process connection Combo flat ph Electrode, PT1000 RTD, 3/4 in. NPT process connection Combo flat ph Electrode, 3KΩ RTD, 3/4 in. NPT process connection Combo flat ph Electrode, PT1000 RTD, 3/4 in. NPT process connection DryLoc ORP (Redox) Electrodes Combination ORP (Redox) Electrode, 10KΩ ID, flat glass Combination ORP Electrode, 10 KΩ ID, bulb glass Differential ORP (Redox) Electrode, 10KΩ ID, 1 in. NPT process connection Differential ORP (Redox) Electrode, PT1000 RTD, 1 in. NPT process connection Differential ORP (Redox) Electrode, 300Ω RTD, 1 in. NPT process connection Differential ORP (Redox) Electrode, 10KΩ ID, 1 in. NPT process connection Differential ORP (Redox) Electrode, PT1000 RTD, 1 in. NPT process connection Differential ORP (Redox) Electrode, 300Ω TC, 1 in. NPT process connection Combo flat ORP (Redox) Electrode, 10 KΩ ID, 3/4 in. NPT process connection Combo flat ORP (Redox) Electrode, no Temp, 3/4 in. NPT process connection Combo bulb ORP (Redox) Electrode, 10 KΩ ID, 3/4 in. NPT process connection Combo bulb ORP (Redox) Electrode, no Temp, 3/4 in. NPT process connection SIGNET George Fischer Signet Inc, 3401 Aerojet Avenue, El Monte, CA U.S.A. Tel. (626) Fax (626) For Worldwide Sales and Service, visit our website: Or call (in the U.S.): (800) GEORGE FISCHER +GF+ Piping Systems (A-3/04) English Scientific Company 2004 Printed in U.S.A. on Recycled Paper
Signet 2760 DryLoc ph/orp Preamplifier
Signet 2760 DryLoc ph/orp Preamplifier *3-2760.090* 3-2760.090 Rev. H 05/11 English English SAFETY INSTRUCTIONS 1. Depressurize and vent system prior to installation or removal. 2. Confi rm chemical compatibility
More information* * Rev. 9 01/18 Product Manual
English Signet 2760 DryLoc ph/orp Preamplifier *3-2760.090* 3-2760.090 Rev. 9 01/18 Product Manual Description The Signet 2760 ph/orp Preamplifiers with DryLoc connectors are part of Signet's growing line
More informationSignet 2760 DryLoc ph/orp Preamplifiers & Connectors
Signet 2760 DryLoc ph/orp Preamplifiers & Connectors Features In-line integral mount and submersible installation versions Automatic temperature compensation Auto configuration for ph or ORP operation
More informationSIGNET 2750 ph/orp Sensor ENGLISH
ENGLISH 3-2750.090 B-8/01 English SAFETY INSTRUCTIONS FOR IN-LINE ELECTRODE INSTALLATION 1. Do not remove from pressurized lines. 2. Do not exceed maximum temperature/pressure specifications. 3. Wear safety
More informationSignet DryLoc ph/orp Electrodes
Signet 2774-2777 DryLoc ph/orp Electrodes Features Patented DryLoc connector with gold plated contacts* Special design allows for installation at any angle, even inverted or horizontal Quick temperature
More informationSignet DryLoc ph/orp Electrodes
Signet 2774-2777 DryLoc ph/orp Electrodes Features Patented DryLoc connector with gold plated contacts* Special design allows for installation at any angle, even inverted or horizontal Quick temperature
More informationSignet ph/orp Electrodes
Signet 2724-2726 ph/orp Electrodes Compatible with ALL Signet ph/orp Instruments Features Flat Glass Protected Bulb Patented reference design for exceptional performance * Mounts in Signet standard fittings
More informationSignet 3719 ph/orp Wet-Tap
Signet 3719 ph/orp Wet-Tap *3-3719.090* 3-3719.090 Rev H 09/07 English Do not exceed maximum temperature/pressure specifications. Wear safety goggles or face shield during installation/service. Do not
More informationSignet ph/orp Electrodes
Signet 2734-2736 ph/orp Electrodes Compatible with Signet 8900/9900 Instruments Features Patented reference design for exceptional performance * Mounts in Signet standard fittings from DN15 to DN100 (½
More informationSignet ph/orp Electrodes
Signet 2724-2726 ph/orp Electrodes Compatible with ALL Signet ph/orp Instruments Features Patented reference design for exceptional performance * Mounts in Signet standard fittings from DN15 to DN100 (½
More information* * Signet 2450 Pressure Sensor. Product Manual. English. Description. Dimensions Rev /18
English Signet 2450 Pressure Sensor *32450.0901* 32450.0901 Rev. 13 03/18 Product Manual Description The 2450 Pressure Sensor has a onepiece injection molded PVDF body and ceramic diaphragm for superior
More informationSIGNET 3719 ph/orp Wet-Tap
ENGLISH 3-3719.090 B-6/02 English Do not exceed maximum temperature/pressure specifications. Wear safety goggles or face shield during installation/service. Do not attempt to disassemble the retraction
More informationSIGNET 7002 Vortex Flow Sensor ENGLISH
SIGNET 7002 Vortex Flow Sensor ENGLISH 3-7002.090 C-7/02 English SAFETY INSTRUCTIONS 1. Do not remove from pressurized lines. 2. Never install sensor without O-Rings. 3. Confirm chemical compatibility
More informationSignet ph/orp Transmitter
Signet 87501 ph/orp English *38750.0901* 38750.0901 Rev. F 3/06 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury.
More informationSignet 3719 ph/orp Wet-Tap Assembly
Signet 3719 ph/p Wet-Tap Assembly Features Electrode removal without process shutdown Space saving 45 mm (1.75 in.) short-stroke design Sealed pneumatic dampening for smooth and safe operation SafeLoc
More informationSignet Temperature Transmitter
Signet 80 Temperature English 80.090 80.090 Rev. G /0 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury. Contents.
More informationSIGNET Vortex Flow Sensors ENGLISH
DN X DN X DN X DN X DN X DN X DN X SIGNET Vortex Flow Sensors ENGLISH 37000.090 C12/00 English 1. Mounting Location... 1 2. Installation... 1 3. Wiring Preparation... 2 4. Wiring Options Frequency Output
More informationSignet Conductivity/Resistivity Electrodes
Signet 2818-2823 Conductivity/Resistivity Electrodes 2818 2819 2820 2821 2822 2823 Sanitary Features Standard process connections - Polypro - SS on 10 and 20 cell - Tri-clamp 1-1½ in., 2 in. - Opt. ½ in.
More informationSIGNET Temperature Transmitter
SIGNET 83501 Temperature *38350.0901* English 38350.0901 Rev. G 3/06 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury.
More informationSignet Pressure Transmitter
Signet 8450 Pressure English 8450.090 8450.090 Rev. G /06 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury. Contents
More informationSignet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems with PVDF Sensor
Signet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems with PVDF Sensor Features Test certificate supplied with all sensors Universal Mount Custom cell constant programmed into the
More informationSignet 7000/7001 Vortex Flow Sensors * *
DN X DN X DN X DN X DN X DN X DN X Signet 7000/7001 Vortex Flow Sensors *3-7000.090* 3-7000.090 Rev. F 10/05 English English 1. Mounting Location... 1 2. Installation... 1 3. Wiring Preparation... 2 4.
More informationSignet Conductivity/Resistivity Electrodes
Signet 2818-2823 Conductivity/Resistivity Electrodes 2818 2819 2820 2821 2822 2823 Sanitary Features Standard process connections - Polypro - SS on 10 and 20 cell - Tri-clamp 1-1½ in., 2 - Opt. ½ in. NPT
More informationSignet V(D) to V(D) PVDF Conductivity Electrodes
Signet 2839-1V(D) to 2842-1V(D) PVDF Conductivity Electrodes Features ± 2% accuracy - Custom calibration certificate provided Dual-threaded Compact electrode length for easy in-line installation in small
More informationPipe fittings MUST be installed by a certified welder only. +GF+ SIGNET will not assume liability of any kind for improper fitting installations.
+GF+ SIGNET 0 High Performance Flow Sensor (English) -0.090- F-/99 English SAFETY INSTRUCTIONS. Do not remove from pressurized lines.. Do not exceed maximum temperature/pressure specifications.. Do not
More informationSignet 2517 Brass Paddlewheel Flow Sensor * *
Signet 2517 Brass Paddlewheel Flow Sensor -250.090 English -2517.090 Rev. F 11/06 English SAFETY INSTRUCTIONS 1. Do not remove from pressurized lines. 2. Do not exceed maximum temperature/pressure specifi
More information* * Rev. F 03/16 Operating Instructions
English Signet 2552 Metal Magmeter *3-2552.090* 3-2552.090 Rev. F 03/16 Operating Instructions 3-2552-2 3-2552-3 Description The Signet 2552 Metal Magmeter from Georg Fischer features all-stainless steel
More informationph/orp Sensor Model 399 ph/orp
Model 399 ph/orp Product Data Sheet PDS 71-399 September 1999 ph/orp Sensor DOUBLE JUNCTION REFERENCE CELL provides longer sensor life in process solutions containing poisoning ions. ONE-PIECE CONSTRUCTION
More informationPipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations.
Signet 50 High Performance Flow Sensor English *3-50.090* 3-50.090 C 05/06 English SAFETY INSTRUCTIONS 1. Do not remove from pressurized lines.. Do not exceed maximum temperature/pressure specifi cations.
More informationNEW QUICK CABLE-TO-SENSOR RELEASE,
Models 399 and 399VP Product Data Sheet PDS 71-399 October 2000 ph/orp Sensors NEW OPTIONS to meet a variety of application requirements, including: * Low ionic strength water * Processes with hydrofluoric
More informationPipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations.
Signet 50 High Performance Flow Sensor English *3-50.090* 3-50.090 Rev. F 11/1 English For the most up-to-date information, please refer to our website at www.gfsignet.com SAFETY INSTRUCTIONS 1. Do not
More informationUser s Guide Shop online at omega.com SM For latest product manuals: CDE-285X SERIES Conductivity Sensors
User s Guide Shop online at omega.com SM e-mail: info@omega.com For latest product manuals: www.omegamanual.info CDE-285X SERIES Conductivity Sensors omega.com info@omega.com U.S.A. Headquarters: Servicing
More informationSignet 2552 Metal Magmeter
Signet 2552 Metal Magmeter *3-2552.090* 3-2552.090 Rev E 07/10 English English SAFETY INSTRUCTIONS 1. Depressurize and vent systems without Hot-tap valve prior to installation or removal. 2. Confirm chemical
More informationSignet 2552 Metal Magmeter
Signet 2552 Metal Magmeter *3-2552.090* 3-2552.090 Rev D 06/08 English English SAFETY INSTRUCTIONS 1. Depressurize and vent systems without Hot-tap valve prior to installation or removal. 2. Confi rm chemical
More informationSignet 4150 Turbidimeter
C L I S T E D 113783 US 4150 Turbidimeter Features Description The 4150 Turbidimeter system provides accurate and reliable compliant water quality monitoring for municipal and industrial applications.
More informationSignet Pressure Transmitter
Signet 80 Pressure 80.090 80.090 Rev. J 0/ English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury. Contents. Installation.
More information+GF+ SIGNET Conductivity Transmitter. Instruction Manual GEORGE FISCHER +GF+
+GF+ SIGNET 3-8800 Conductivity Transmitter Instruction Manual GEORGE FISCHER +GF+ SAFETY INSTRUCTIONS 1. Do not remove from pressurized lines. 2. Do not exceed maximum temperature/pressure specifications.
More informationMeasurement and Instrumentation
15 Measurement and Instrumentation Use the postcard included in this handbook or call (800) 854-4090 to order the complete Instrumentation Catalog or visit www.gfsignet.com for detailed product information.
More informationGeneral Purpose ph/orp Sensors
General Purpose ph/orp Sensors Product Data Sheet LIQ_PDS_3900 September 2013 General Purpose ph/orp Sensors SMART preamplifier-stores calibration and other data. Extended sensor life provided by double
More informationChapter Page. 1 Introduction Description 1
Chapter Page 1 Introduction 1 1.1 Description 1 Table of Contents 2 Calibration 3 2.1 Wet Calibration 3 2.2 Calibration Procedure 4 2.3 Installing Optional Display Board 5 2.4 Display Board Range Adjustment
More informationGeneral Purpose ph/orp Sensors
Product Data Sheet PDS 71-3900/rev. B December 2010 Models 3900 and 3900VP General Purpose ph/orp Sensors EXTENDED SENSOR LIFE provided by double junction reference. ENHANCED PERFORMANCE AND INCREASED
More informationInstrument Enclosure Assemblies
Instrument Enclosure Assemblies Standard instrument enclosure Instrument enclosures offer a simple solution for the customer who doesn t have the time to install Signet meters into panels. Whether it s
More informationSignet 515 Rotor-X Paddlewheel Flow Sensors
Signet 515 Rotor-X Paddlewheel Flow Sensors Features Operating range 0.3 to 6 m/s (1 to 20 ft/s) Wide turndown ratio of 20:1 Highly repeatable output Simple, economical design Installs into pipe sizes
More informationSignet 515 Rotor-X Paddlewheel Flow Sensors
Signet 515 Rotor-X Paddlewheel Flow Sensors Features Operating range 0.3 to 6 m/s (1 to 20 ft/s) Wide turndown ratio of 20:1 Highly repeatable output Simple, economical design Installs into pipe sizes
More informationModels 396/396P/396R. Retraction/Submersion/Insertion ph/orp Sensor
Models 396/396P/396R Product Data Sheet PDS 71-TUpH September 1999 Retraction/Submersion/Insertion ph/orp Sensor MINIMUM SENSOR MAINTENANCE due to patented TUpH reference technology 1 which ensures steady
More informationSignet 2536 Rotor-X Paddlewheel Flow Sensors
Signet 2536 Rotor-X Paddlewheel Flow s Features Operating range 0.1 to 6 m/s (0.3 to 20 ft/s) Wide turndown ratio of 66:1 Open-collector output Highly repeatable output Simple, economical design PVC (gray
More information* * Rev M 10/14 Operating Instructions
English Signet 55 Blind Magmeter *-55.090* -55.090 Rev M 0/ Operating Instructions Description The Signet 55 Magmeter is an insertion-style magnetic flow sensor. The patented sensor design is available
More informationUser s Guide CDCE-90-X SERIES. Conductivity Sensors. Shop online at omega.com SM
User s Guide Shop online at omega.com SM e-mail: info@omega.com For latest product manuals: www.omegamanual.info CDCE-90-X SERIES Conductivity Sensors omega.com info@omega.com U.S.A. Headquarters: Servicing
More informationEncapsulated Differential ph and ORP Sensors (available in LCP, foreground, or Ryton body materials)
Technology For Solutions Data Sheet LRE/102 Supersedes LRE/400 Encapsulated Differential ph and ORP Sensors (available in LCP, foreground, or Ryton body materials) Common Features Differential Electrode
More informationSignet 515/2536 Rotor-X Flow Sensors * * Operating Instructions. English. Description Rev. X 05/17
English Signet 515/2536 Rotor-X Flow Sensors *3-0515.090* 3-0515.090 Rev. X 05/17 Operating Instructions 515 Sensor (with red cap) 2536 Sensor (with blue cap) 8510 Integral Sensor 8512 Integral Sensor
More informationInsertion/Submersion Flow Through Sensor
Product Data Sheet PDS 71-381/rev.B September 2004 Model 381 ph/orp Insertion/Submersion Flow Through Sensor ADVANCED ON-LINE SENSOR DIAGNOSTICS 1 (Model 381+ only), for use with the Models 54e ph/orp
More information7777 Immersion/In-Line Mounting for Meredian II ph/orp Electrodes Installation and Maintenance Manual
7777 Immersion/In-Line Mounting for Meredian II ph/orp Electrodes Installation and Maintenance Manual 70-82-25-05 Rev. 1 3/08 Honeywell Process Solutions Copyright, Notices, and Trademarks Printed in U.S.A.
More informationOPERATING INSTRUCTION MANUAL
OPERATING INSTRUCTION MANUAL MODEL P/R65 DIFFERENTIAL 2-WIRE (4-20 ma) ph & ORP PROBES N116-139 REV. 0 Aquametrix, by Water Analytics Inc. 100 School Street Andover, MA 01810 Tel: (978) 749-9949 Toll Free:
More informationSignet 2552 Magmeter. English * * Specifications. Safe to operate Hot-tap
Signet 2552 Magmeter *3-2552.090* 3-2552.090 Rev. A 11/06 English SAFETY INSTRUCTIONS 1. Depressurize and vent systems without Hot-tap valve prior to installation or removal. 2. Confi rm chemical compatibility
More information+GF+ SIGNET 2550 Insertion Magmeter
+GF+ SIGNET 2550 Insertion Magmeter Instruction Manual GEORGE FISCHER +GF+ Important Safety Information! CAUTION: Do not remove from pressurized lines! Do not remove safety ring from sensor. Unit may become
More informationOPERATING INSTRUCTION MANUAL MS SERIES CONDUCTIVITY CELLS
OPERATING INSTRUCTION MANUAL MS SERIES CONDUCTIVITY CELLS REV. 3.1 Water Analytics, Inc. 100 School Street Andover, MA 01810 978-749-9949 Toll free: 855-747-7623 Fax: 978-749-9961 www.wateranalytics.net
More informationAccessories Guide ph/orp/conductivity Sensors
Jet Cleaners and Scrubber Accessories Isolation Ball Valves Assemblies Compression Fittings and Sheath Sets High Pressure (2500 PSIG) Sensor Housings In-line Flow Cells Nut Lock Union Style Adapters Sensor
More informationGF Signet. Measurement & Control Sensors. Signet Price List 1st Aug 2011 Rev 0.0
GF Signet Measurement & Control Sensors Sensors and Transmitters: Flow ph Conductivity ORP Level Pressure Temperature Turbidity Chlorine Installation fittings Power supplies Calibration solutions Accessories
More informationUser s Guide PH-2720-PA. Preamplifier. Shop online at.
User s Guide Shop online at www.omega.com e-mail: info@omega.com Preamplifier OMEGAnet Online Service www.omega.com Internet e-mail info@omega.com Servicing North America: USA: One Omega Drive, P.O. Box
More informationSignet 2551 Magmeter Flow Sensor
Signet 2551 Magmeter Flow Sensor Available in a variety of wetted materials and ideal for pipe sizes up to DN900 (36 in.) Features Test certificate included for -X0, -X1 Patented Magmeter technology No
More informationConductivity Sensors. Model 140, 141, 142. Product Data Sheet series/rev.a June 1998
Product Data Sheet 71-140 series/rev.a June 1998 Model 140, 141, 142 Conductivity Sensors HIGH TEMPERATURE 316 SS AND PEEK CON- STRUCTION operates up to 200 C (392 F). MODEL 140 RETRACTABLE SENSOR installs
More information7777D In-Line Mounting for Durafet II ph Electrodes Installation and Maintenance
7777D In-Line Mounting for Durafet II ph Electrodes Installation and Maintenance 70-82-25-121 Rev. 0 3/07 Honeywell Process Solutions Industrial Measurement and Control Copyright, Notices, and Trademarks
More informationMeasurement & Instrumentation 2005 Product Catalog on CD. Creating Quality by Connecting Technology to Life. Click on image to begin.
Measurement & Instrumentation 2005 Product Catalog on CD Creating Quality by Connecting Technology to Life Click on image to begin. Main Contents Measurement & Instrumentation 2005 Product Catalog Flow
More informationAnalytical Instruments Two-Electrode Conductivity Sensors
Data Sheet Analytical Instruments Two-Electrode Conductivity Sensors Model TB2 Superior accuracy in low conductivity measurement ranges. Measurement ranges from 0 to 199.9 µs/cm to 0 to 19.99 ms/cm. Resolution
More information2100 Turbine Flow Sensor
200 Turbine Flow Sensor Description Engineered specifically for small pipe diameter applications, the Signet 200 Turbine Flow Sensor provides accurate readings in two flow ranges: 0.3 to 3.8 lpm and 3
More informationHydro-Flow 2200 Fixed Insertion Vortex Flow Meter
A trademark of Spirax Sarco, Inc. Hydro-Flow 2200 Fixed Insertion Vortex Flow Meter Description The Hydro-Flow Model 2200 fixed insertion vortex flow meter was designed specifically for water flow measurement,
More informationTUpH Retraction/Submersion/Insertion ph/orp Sensors
Product Data Sheet PDS 71-TUpHVP/rev.B June 2003 Models 396VP, 396RVP, 398VP, & 398RVP TUpH Retraction/Submersion/Insertion ph/orp Sensors SILCORE 3 TECHNOLOGY PROVIDES INCREASED SENSOR LIFE when used
More information* * Rev /18 Operating Instructions
English Signet 255 Blind Magmeter *-2552.090* -255.090 Rev. 6 07/8 Operating Instructions Description The Signet 255 Magmeter is an insertion-style magnetic flow sensor. The patented sensor design is available
More information8000 Series ph/orp Electrode Platform Product Instructions
8000 Series ph/orp Electrode Platform Product Instructions Introduction Congratulations on your purchase of your Sensorex S8000 series electrode platform. The platform is designed in a modular fashion
More informationToroidal Conductivity Sensor
Instruction Sheet PN 51A-222/rev.A January 2011 Model 222 Toroidal Conductivity Sensor For additional information, please visit our website at www.emersonprocess.com/raihome/liquid/. SPECIFICATIONS Wetted
More informationGeneral Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.K February 2013
Product Data Sheet PDS 71-400/rev.K February 2013 Model 400 and 400VP Series ENDURANCE General Purpose Conductivity Sensors INITIAL CALIBRATION NOT REQUIRED. Factory-measured cell constant ensures out-of-the-box
More informationGeneral Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.G February 2006
Product Data Sheet PDS 71-400/rev.G February 2006 Model 400 and 400VP Series ENDURANCE General Purpose Conductivity Sensors INITIAL CALIBRATION NOT REQUIRED. Pre-determined cell constant ensures out-of-the
More information7777 Immersion/In-Line Mounting for Durafet II ph Electrodes Installation and Maintenance
7777 Immersion/In-Line Mounting for Durafet II ph Electrodes Installation and Maintenance 70-82-25-86 Rev. 1 4/00 Sensing and Control Copyright, Notices, and Trademarks Printed in U.S.A. Copyright 2000
More informationTable of Contents 1. OVERVIEW OPERATION FUNCTION SPECIFICATIONS INSTRUMENT LAYOUT INSTALLATION...
Table of Contents 1. OVERVIEW... 2 2. OPERATION FUNCTION... 2 3. SPECIFICATIONS... 3 4. INSTRUM LAYOUT... 4 4.1 OPERATION KEY...4 4.2 INDICATORS...4 5. INSTALLATION... 5 5.1. ENVIRONM CONDITIONS...5 5.2
More informationSignet Measurement and Instrumentation
F Piping Systems Signet Measurement and Instrumentation Price List effective January 1, 2015 Conveyance Pipe, Fittings, Joining Technology // PVC/CPVC // PPro-Seal PP // PROEF PP // SYEF PVDF // Contain-It
More informationABB MEASUREMENT & ANALYTICS DATA SHEET. TBX5 ph, Redox (ORP) sensors with diagnostics
BB MESUREMENT & NLYTICS DT SHEET TBX ph, Redox (ORP) sensors with diagnostics Measurement made easy The most durable ph / Redox (ORP) sensors in the world Next Step Solid State reference eliminates poisoning,
More informationAutomation Made Easy 2013 Signet Measurement and Control Product Catalog
Multi-Parameter Chlorine Dissolved Oxygen Turbidity Flow ph/orp Conductivity/Resistivity Temperature Pressure Level Automation Made Easy 2013 Signet Measurement and Control Product Catalog Automation Made
More informationCombination ph/redox (ORP) Sensors
Data Sheet Combination ph/redox (ORP) s Series AP00 User-customizable for Insertion, Flow-through, Immersion, Hot-tap Retractor ideal for Original Equipment Manufacturers and general applications Economical
More informationCombination ph/redox (ORP) Sensors
Data Sheet SS/AP00_ Combination ph/redox (ORP) s AP00 Series User-customizable for Insertion, Flow-through, Immersion and Hot-tap Retractor ideal for OEMs (Original Equipment Manufacturers) and general
More informationConductivity Sensors. Model 140, 141, 142. Product Data Sheet series/rev.b February 2011
Product Data Sheet 71-140 series/rev.b February 2011 Model 140, 141, 142 Conductivity Sensors RUGGED CONSTRUCTION withstands high temperature and pressure TWO MOUNTING CONFIGURATIONS: screw-in and retractable
More informationRosemount 3300HT/3300HTVP/3400HT/ 3400HTVP/3500P/3500VP
Instruction Manual LIQ-MAN-PERpH-X Rev. J April 2017 Rosemount 3300HT/3300HTVP/3400HT/ 3400HTVP/3500P/3500VP PERpH-X High Performance ph/orp Sensors hasgkas Essential Instructions Read this page before
More informationGeneral Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.I December 2008
Product Data Sheet PDS 71-400/rev.I December 2008 Model 400 and 400VP Series ENDURANCE General Purpose Conductivity Sensors INITIAL CALIBRATION NOT REQUIRED. Pre-determined cell constant ensures out-of-the
More informationA1 Commercial Grade Meters
A1 Commercial Grade Meters Commercial Grade Meters are designed as self-contained, battery powered units. These indicating meters come in Aluminum or Nylon only. A1 Meters are not field serviceable like
More informationConductivity Sensors. Applications. 140 Series Conductivity Sensors Product Data Sheet LIQ_PDS_140_141_142_Conductivity_Sensors January 2014
140 Series Conductivity Sensors Product Data Sheet LIQ_PDS_140_141_142_Conductivity_Sensors January 2014 Conductivity Sensors Rugged construction withstands high temperature and pressure Two Mounting Configurations:
More informationAD592/592-10K Non-Room Sensors in BAPI-Box, BAPI-Box 2 or BAPI-Box 4 BA/592-x-(BB, BB2, BB4) Temperature Sensor Instructions & Operation
592 Theory of Operation The 592 sensor is a two terminal integrated-circuit temperature sensor. The 592 provides an output current directly proportional to absolute temperature. When the temperature of
More informationRetractable ph/orp Sensors
Model 396R and 396RVP Instruction Manual PN 5100396R January 2001 Retractable ph/orp Sensors ESSENTIAL INSTRUCTIONS READ THIS PAGE BEFORE PROCEEDING! Rosemount Analytical designs, manufactures, and tests
More informationPRESSURE TRANSDUCERS. Specifications. Individual Specifications
00 Series and 00 Heavy Duty Series Compact OEM Pressure Transmitters 0 50 psi to 0-0,000 psi ranges (0-.5 bar to 0-,00 bar) High Proof Pressures Broad Choice of Outputs RoHS Compliant For OEMs that need
More informationSignet Measurement and Instrumentation
F Piping Systems Signet Measurement and Instrumentation Price List effective January 1, 2018 NEW! DryLoc ph/orp Smart Sensor Electronics See page 37 for new lower pricing on Portaflow Ultrasonic Flow Meters!
More informationACTIVE ELECTRODELESS SENSORS Instruction Manual
W A L C H E M An Iwaki America Company Active Electrodeless Sensors ACTIVE ELECTRODELESS SENSORS Instruction Manual Five Boynton Road Hopping Brook Park Holliston, MA 01746 USA TEL: 508-429-1110 FAX: 508-429-7433
More informationP2050S-030, 1/2, Electronic Pressure Independent Valve Stainless Steel Ball and Stem, Female NPT Ends
P2050S-030, 1/2, Electronic Pressure Independent Valve Stainless Steel Ball and Stem, Female NPT Ends Application Water-side control of heating and cooling systems for AHUs and water coils. Equal Percentage/
More information2-ELECTRODE CONDUCTIVITY SENSORS
LAKEWOOD INSTRUMENTS MODEL 540 2-ELECTRODE CONDUCTIVITY SENSORS INSTALLATION & OPERATION MANUAL 540K.1 540K.01 Lakewood Instruments 7838 North Faulkner Road, Milwaukee, WI 53224 USA Phone (800) 228-0839
More informationUser s Guide FMG-550 SERIES OMEGAMAG. Shop online at omega.com SM For latest product manuals:
User s Guide Shop online at omega.com SM e-mail: info@omega.com For latest product manuals: www.omegamanual.info FMG-550 SERIES OMEGAMAG omega.com info@omega.com U.S.A. Headquarters: Servicing North America:
More informationRosemount TM 222 Toroidal Flow-Through Conductivity Sensor. Instruction Manual LIQ-MAN-222 Rev.D June 2017
Rosemount TM 222 Toroidal Flow-Through Conductivity Sensor Instruction Manual LIQ-MAN-222 Rev.D June 2017 SPECIFICATIONS Wetted Materials: Teflon-lined carbon steel pipe, with carbon steel outer flanges.
More informationSelectable ranges and an LCD are a technician s best friend, that s why we make them standard on every dry media differential pressure sensor!
PRESSURE SENSORS PRESSURE PDP3 Series 0-2 32 PDP3 Series 0-10, 0-25 34 PG Gauge Series 36 PW Wet-Wet Series (Cable Version) 38 PW Wet-Wet Series (Conduit Version) 40 PW Series Ordering Guidance 42 Selectable
More informationTUpH 396, 396VP, 396P, 396PVP, 396R, 396RVP
TUpH 396, 396VP, 396P, 396PVP, 396R, 396RVP Product Data Sheet LIQ-PDS-396P-PVP-R-RVP April 2016 TUpH 396, 396VP, 396P, 396PVP, 396R, 396RVP Retraction/Submersion/Insertion ph/orp Sensors Smart enabled
More informationHydro-Flow 2300 Fixed Insertion Vortex Flow Meter
Hydro-Flow 2300 Fixed Insertion Vortex Flow Meter Description The Hydro-Flow Model 2300 insertion vortex flow meter was designed specifically for water flow measurement, containing no moving parts like
More informationMS Application. Features. Proportional Valve Actuator General Instructions
Proportional Valve Actuator Application The Proportional Valve Actuator is a non-spring return actuator used with proportional to 10 Vdc or 4 to 0 ma controllers and standard 1/" to 1-1/4" two-way and
More informationINTERNATIONAL METAL ENGINEERING
INDICATING TEMPERATURE TRANSMITTER WITH HART 8080HT UNIVERSAL SETTINGS WITH HART PROTOCOL FOR VARIOUS INPUT SIGNALS 2 WIRE TECHNOLOGY, 4 TO 20mA ANALOG OUTPUT HIGH ACCURACY IN TOTAL AMBIENT TEMPERATURE
More informationCombination ph/orp Sensor
Model GP1 Instruction Manual PN 5100GP1 May 1999 Combination ph/orp Sensor ESSENTIAL INSTRUCTIONS READ THIS PAGE BEFORE PROCEEDING! Rosemount Analytical designs, manufactures, and tests its products to
More informationUser s Guide FP-5060 SERIES. Micro-Flow Sensors. Shop online at omega.com SM For latest product manuals:
User s Guide Shop online at omega.com SM e-mail: info@omega.com For latest product manuals: www.omegamanual.info FP-5060 SERIES Micro-Flow Sensors omega.com info@omega.com U.S.A. Headquarters: Servicing
More information