* * Rev M 10/14 Operating Instructions

Size: px
Start display at page:

Download "* * Rev M 10/14 Operating Instructions"

Transcription

1 English Signet 55 Blind Magmeter * * Rev M 0/ Operating Instructions Description The Signet 55 Magmeter is an insertion-style magnetic flow sensor. The patented sensor design is available in a variety of corrosion-resistant materials to provide longterm reliability and minimal maintenance costs. Wetted material combinations include PP/6 SS, PVDF/Hastelloy-C and PVDF/Titanium. The 55 installs quickly and securely into a wide selection of flow fittings to deliver accurate flow measurement in pipe sizes ranging from DN5 to DN900 (½ in. to 6 in.). Signet 55 Magmeters are available with a frequency output or Digital (S L) output for use with the Signet 9900-BC Batch Controller, 8900 Multi-Parameter Controller or 9900 Transmitter, or with a to 0 ma output for a direct input to a PLC, SCADA or telemetry system. All 55 Magmeters feature empty pipe detection and LED-assisted diagnostics. The Signet -050 USB to Digital (S L) set-up tool is available to customize every performance feature in the 55 to adapt it to the specific application requirements. Table of Contents English Deutsch Français Español Italiano Português Quick Start... Warranty Information... Product Registration... Safety Information... Chemical Compatibility... Specifications... Dimensions... Installation: Pipe Fittings... Selecting a Location... Hardware Configuration...5 General Installation and Grounding Tips...6 Wiring with to 0 ma Loop...6 Wiring with Frequency or Digital (S L) Output...7 Calibration and Software Configuration...7 Calibration Data...8 Maintenance and Troubleshooting...0 Ordering Information...

2 Warranty Information Refer to your local Georg Fischer Sales office for the most current warranty statement. All warranty and non-warranty repairs being returned must include a fully completed Service Form and goods must be returned to your local GF Sales office or distributor. Product returned without a Service Form may not be warranty replaced or repaired. Signet products with limited shelf-life (e.g. ph, ORP, chlorine electrodes, calibration solutions; e.g. ph buffers, turbidity standards or other solutions) are warranted out of box but not warranted against any damage, due to process or application failures (e.g. high temperature, chemical poisoning, dry-out) or mishandling (e.g. broken glass, damaged membrane, freezing and/or extreme temperatures). Product Registration Thank you for purchasing the Signet line of Georg Fischer measurement products. If you would like to register your product(s), you can now register online in one of the following ways: Visit our website Under Service and Support click on Product Registration Form If this is a pdf manual (digital copy), click here Chemical Compatibility The retaining nuts of Magmeters are not designed for prolonged contact with aggressive substances. Strong acids, caustic substances and solvents or their vapor may lead to failure of the retaining nut, ejection of the sensor and loss of the process fluid with possibly serious consequences, such as damage to equipment and serious personal injury. Retaining nuts that may have been in contact with such substances, e.g. due to leakage or spilling, must be replaced. Dimensions Pipe Range: / to in. -X0 = 58 mm (. in.) 5 to 8 in. -X = 9 mm (.6 in.) 0 to 6 in. -X = 67 mm (6.6 in.) X = Sensor Body P, T, or V 79.5 mm (. in.) -X0 -X -X 9 mm (.7 in.) Safety Information Depressurize and vent system prior to installation or removal. Confirm chemical compatibility before use. Do not exceed maximum temperature/pressure specifications. Wear safety goggles or face shield during installation/service. Do not alter product construction. Disconnect power before attempting any service or wiring Caution / Warning / Danger Indicates a potential hazard. Failure to follow all warnings may lead to equipment damage, injury, or death Electrostatic Discharge (ESD) / Electrocution Danger Alerts user to risk of potential damage to product by ESD, and/or risk of potential of injury or death via electrocution. Personal Protective Equipment (PPE) Always utilize the most appropriate PPE during installation and service of Signet products. Pressurized System Warning Sensor may be under pressure, take caution to vent system prior to installation or removal. Failure to do so may result in equipment damage and/or serious injury. Hand Tighten Only Overtightening may permanently damage product threads and lead to failure of the retaining nut. Do Not Use Tools Use of tool(s) may damage product beyond repair and potentially void product warranty. Operating Temperature/Pressure (psi) (bar) C F Blind Magmeter

3 Specifications General Pipe size range... DN5 to DN 900 (0.5 in. to 6 in.) Flow Range... Minimum: 0.05 m/s (0.5 ft/s) Maximum... 0 m/s ( ft/s) Linearity... ± % reading plus 0.0m/s (0.0 ft/s) Repeatability... ± 0.5% of 5 C (77 F) Min. Conductivity... 0 µs/cm Wetted Materials: Sensor body and Electrodes and Grounding ring -P0, -P, -P... Polypropylene and 6L SS -T0, -T, -T... PVDF and Titanium -V0, -V,-V... PVDF and Hastelloy-C O-rings... FPM (standard); EPDM,... FFPM (optional) The user is responsible for determining the chemical suitability of these materials for a specific application. Electrical Power Requirements to 0 ma....6 to 6. VDC,. ma max. Frequency... 5 to 6. VDC, 5 ma max. Digital (S L)... 5 to 6.5 VDC, 5 ma max. Reverse polarity and short circuit protected Current output ( to 0 ma) Loop Accuracy... µa max. error (5 VDC) Isolation... Low voltage < 8 VAC/DC from electrodes and auxilary power Max cable m (000 ft) Error condition.... ma Max. Loop Resistance Ω Compatible with PLC, PC or similar equipment Frequency output Max. Pull-up Voltage... 0 VDC Compatible with Signet 8900, 9900, 9900-BC Digital (S L) Output Serial ASCII, TTL level 9600 bps Compatible with Signet 8900, 9900 Environmental Requirements Case... PBT Display... Polyamide Storage Temperature to 70 C (- to 58 F) Relative Humidity... 0 to 95% (non-condensing) Operating Temperature Ambient C to 70 C ( F to 58 F) Media... 0 C to 85 C ( F to 85 F) Max. operating pressure C (50 77 F). 85 C (0 85 F) Standards and Approvals CE, UL NEMA X / IP65 Enclosure (with cap installed) China RoHS For more information go to Declaration of Conformity according to FCC Part 5 This device complies with Part 5 of the FCC rules. Operation is subject to the following two conditions: () This device may not cause harmful interference, and, () This device must accept any interference received, including interference that may cause undesired operation. Quick Start This manual contains the general installation, wiring and calibration data for the Signet 55-XX- Magmeter with Frequency or Digital (S L) data output, and for the Signet 55-XX- Magmeter with to 0 ma output. The basic steps are outlined on this page. See each referenced section for detailed information.. Configure the Hardware 55-XX- ONLY: Position this Jumper to select Digital (S L) output or Frequency output. Pg. 5.. Position the PIPE SIZE jumper according to your pipe size. Pg. 5.. Install the Magmeter into the pipe. Use Signet installation fittings ONLY. The installation fitting is critical to Magmeter performance. Pg... Connect POWER and OUTPUT wiring. Frequency out: Pg. 7. Digital (S L) out: Pg. 7. to 0 ma out: Pg. 6. GROUNDING Without a good earth ground, the Magmeter may not operate efficiently. Pg Route the wiring out through the two cable ports. Use appropriate hardware to secure the 55 from moisture intrusion. One Liquid Tight Connector is included. Pg Sensor FREQUENCY OUT SERIAL (S L) OUT 55-P0/T0/V0 55-P/T/V 55-P/T/V Pipe Size ½ in. to ½ in. DN5 to DN65 in. to in. DN80 to DN00 5 in. to 6 in. DN5 to DN50 8 in. DN00 0 in. to in. DN50 to DN00 JP Jumper Position Connect output signals and power to this -terminal block Blind Magmeter

4 +GF+ +GF+ ENTER Flow +GF+ Flow ENTER Installation Pipe fittings Georg Fischer offers a wide selection of installation fittings that control the position of the Magmeter electrodes in relation to the dimensions of the pipe. You will find a complete list of order numbers for installation fittings in the Calibration Tables on pages 8, 9. Description Description Plastic tees 0.5 to inch versions MPVC or CPVC Iron, Carbon Steel, 6 SS Threaded tees 0.5 to in. versions Mounts on threaded pipe ends PVC Glue-on Saddles PVC Clamp-on Saddles Available in 0 and inch sizes only Cut -/ inch hole in pipe Weld in place using solvent cement to inch, cut -7/6 inch hole in pipe 6 to 8 inch, cut -/8 inch hole in pipe Carbon steel & stainless steel Weld-on Weldolets Fiberglass tees FPT to inch, cut -7/6 inch hole in pipe Over inch, cut -/8 inch hole in pipe.5 in. to in. PVDF insert Iron Strap-on saddles to inch, cut -7/6 inch hole in pipe Over inch, cut -/8 inch hole in pipe Special order in. to 6 in. Union Fittings and Wafers For pipes from DN 5 to 50 mm PP or PVDF Selecting a Location The 55 requires a full pipe and a fully developed turbulent flow profile for accurate measurement. If the piping system harbors air pockets or bubbles, take steps to locate the sensor so the air pockets will not contact the electrodes. In vertical installations, assemble the 55 so the conduit ports are facing downward. This prevents condensation inside the conduit from being directed into the 55 electronics housing. Chemical injection systems can temporarily alter the fluid conductivity and cause anomalies in the magmeter measurement. To avoid this problem, install the magmeter UPSTREAM of the injection point. Flow 6.5 GPM Total 567.8> Signet Flow Transmitter Flow 6.5 GPM Total 567.8> Signet Flow Transmitter Reducer 90 Elbow Select a location with sufficient distance of straight pipe immediately upstream of the sensor. x 90 Elbow 5 x I.D. 5 x I.D. 0 x I.D. 5 x I.D. x 90 Elbow dimensions Pump/Valve 5 x I.D. 5 x I.D. 0 x I.D. 5 x I.D. 50 x I.D. 5 x I.D. Locating the sensor in a trap or where the flow is upward helps to protect the sensor from exposure to air bubbles when the system is in operation. OK OK OK +GF+ Vertical flow is ok if the pipe remains full Vertical flow is OK if the pipe remains full at all times. at all times. These configurations are not recommended because it is difficult to keep the pipe full. +GF+ In a gravity-flow system, the tank must be designed so the level does not drop below the outlet. This causes the pipe to draw air in from the tank. If air bubbles pass across the Magmeter electrodes, the output will become erratic. 55 Blind Magmeter

5 Hardware Configuration Whether using the 55-XX- (with frequency or Digital (S L) output) or the 55-XX- (with to 0 ma output), the wiring terminals located on the inside of the yellow cover are identical. All of the connections from the Magmeter to external equipment (PLC, Datalogger, Chart Recorder, Flow meter, etc.) are made at the large -position terminal connector. When the cover is removed the wiring from the sensor can be seen connected to the smaller terminal block. These connections should always remain connected to prevent inadvertent damage or miswiring. The terminals on the 55 Magmeter are designed for conductors from 6 AWG to AWG. WARNING! If the second conduit port is used, carefully drill the opening. (The plastic is too strong to be punched out.) JP is for factory use only. MAKE NO CONNECTIONS. This blue jumper selects frequency output or S L serial data output in the -55-XX- (Not used on 55-XX- models) JP Set this blue jumper according to the pipe size. Sensor Pipe Size Jumper Position 55-P0/T0/V0 ½ in. to ½ in. DN5 to DN65 55-P0/T0/V0 in. to in. DN80 to DN00 55-P/T/V 5 in. to 6 in. DN5 to DN50 55-P/T/V 8 in. DN00 55-P/T/V 0 in. to in. DN50 to DN00 The user must connect output cables to this -terminal block. Blue Brown Black Red Yellow White Not used External Earth Ground Terminal The factory connects the sensor cable to the terminals inside the yellow cover. Secure the Magmeter in a vise to prevent damage or injury. The plastic inside the port is very thin. Do not allow the drill to penetrate too deeply and damage the Magmeter wiring. Use the yellow decal to mark the direction of flow on the pipe Important: The directional arrow on the sensor body MUST be pointed DOWNSTREAM for correct operation. (Digital (S L) and to 0 ma will not work if flow is against direction of arrow). The FLOW arrow decal can be placed directly on the pipe to identify the direction of flow. Use a cable gland or a liquid tight connector to seal the cable ports from water intrusion. The yellow housing may be reversed to align the conduit ports as required. If the Magmeter is installed on a vertical pipe, the conduit ports should be turned to point downward. This will prevent condensation from being channeled into the enclosure. Use plumber's tape or a suitable sealant on cable ports. Flow Liquid tight connector (one supplied) Sensor grounding ring WARNING! FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN THE SENSOR BEING EJECTED FROM THE PIPE! Flow Do not use any tools to tighten the yellow retaining cap. DO NOT USE thread sealant or lubricants on retaining cap! Lubricate O-rings with a viscous non-petroleum based lubricant (grease) compatible with the system. DO NOT USE ANY TOOLS ON THE RETAINING CAP. HAND TIGHTEN ONLY. LUBRICATE O-RINGS WITH A NON-PETROLEUM BASED, VISCOUS LUBR ICANT (GREASE) COMPATIBLE WITH THE SYSTEM. DO NOT USE thread sealant or lubricants on the fitting threads. DO NOT USE THREAD SEALANT OR LUBRICANTS ON THE RETAINING CAP OR ON THE PLASTIC FITTING THREADS. IF LEAKING IS OBSERVED FROM THE RETAINING CAP, IT INDICATES DEFECTIVE OR WORN O-RINGS ON THE SENSOR. DO NOT ATTEMPT TO CORRECT BY FURTHER TIGHTENING. CHEMICAL COMPATIBILITY WARNING The retaining nuts of Magmeters are not designed for prolonged contact with aggressive substances. Strong acids, caustic substances and solvents or their vapor may lead to failure of the retaining nut, ejection of the sensor and loss of the process fluid with possibly serious consequences, such as damage to equipment and serious personal injury. Retaining nuts that may have been in contact with such substances, e.g. due to leakage or spilling, must be replaced. 55 Blind Magmeter 5

6 General Installation and Grounding Tips Sensor conditioning The Magmeter output signal may be unstable immediately after installation. Allowing the sensor to soak in a full pipe (or in any container of water) for hours will stabilize the performance. Very low conductivity fluids may require a longer conditioning period. (The Magmeter will not operate properly in fluids where the conductivity is less than 0 µs/cm.) Grounding The 55 Magmeter is unaffected by moderate levels of electrical noise. However, in some applications it may be necessary to ground portions of the system to eliminate electrical interference. The grounding requirements will vary with each installation.. One or more of the following steps may be applied if the 55 Magmeter is affected by electrical noise: The ground terminal on the outside of the yellow housing is connected internally to the grounding ring at the tip of the sensor. Connect a wire ( AWG/.08 mm recommended) from this terminal directly to a local Earth ground.. Install fluid grounding devices immediately upstream and downstream of the Magmeter. Connect the fluid grounds to the Earth ground terminal on the 55. Use flanged grounding rings or metal electrodes on plastic pipes, or metal clamps on metal pipes. Fluid grounds must be in direct contact with the fluid, and as near to the Magmeter as possible.. The shield from the output cable must be terminated at the remote instrument ONLY. This shield must be connected at only one end!. Connect an additional wire (minimum AWG /.08 mm ) from the remote instrument ground to the Magmeter ground terminal. Instrument. Do not terminate shield at Magmeter. Sensor Grounding ring in. to 50 in. in. to 50 in. (0 cm to. m) (0 cm to. m). Grounding rings on plastic pipe (Install between flanges) or metal straps on metal pipe.. Earth ground Wiring with to 0 ma Loop Output The 55-XX- Magmeter is a traditional -wire passive to 0 ma loop transmitter. External loop power ( VDC ± 0%) is required. See Ordering Information for power supplies. The maximum loop resistance the Magmeter can accomodate is 00 Ω. All 55-XX- Magmeters are shipped from the factory with the to 0 ma output scaled for 0 to 5 m/s (0 to 6. ft/s). If this operating range is suitable, no adjustments are necessary. The Calibration Tables on pages 8-9 list the 0 ma setpoint for each installation fitting. Use this information to program the to 0 ma range of the loop device (PLC, Datalogger, recorder, etc.) The -050 USB to Digital (S L) Configuration/Diagnostic Tool is required to change the operating range. 55 Magmeter Loop - (Ground) ma Loop monitor (Maximum 00 Ω) Loop + ( VDC) - + VDC ± 0% 6 55 Blind Magmeter

7 0KΩ Wiring with Frequency or Digital (S L) Output Frequency output (Compatible with all POWERED Signet Flow instruments.) When the blue jumper illustrated here is placed over both pins, the 55-XX- outputs an open collector frequency signal that can be connected to any powered Signet flow meter (models 8900, 9900, 9900-BC). 5 VDC power is provided to the 55 Magmeter by all Signet flow instruments. No additional power is required. The frequency output will be displayed as positive flow regardless of the flow direction. Blue Jumper ON = FREQ OUT Frequency 55 Wiring to Signet 8900 Freq. Not used Ground 55 Wiring to Signet 9900 and 9900-BC 9900 Transmitter V+ DATA GND SHLD I/O Module X Frequency +5VDC (Black) Input Freq. Input (Red) GND (Shield) Frequency +5VDC (Black) Input Freq. Input (Red) OR S L Input S L Input S L (Red) GND (White/Shield) +5VDC (Black) S L (Red) GND (White/Shield) C Data +5 VDC 55 Magmeter S L 55 Magmeter Not used Ground Frequency or S L +5 VDC Digital (S L) Output (Compatible with 8900 Multi-Parameter Controller and 9900 Transmitter only) When the blue jumper illustrated here is removed (or placed over one pin for storage) the 55-XX- outputs a Digital (S L) signal compatible with the Signet 8900 and The 55 receives 5 VDC power from the 8900 or No additional power is required. The 8900 will display 0 (Zero) flow rate during periods of reverse flow. The 9900 will display negative numbers to indicate reverse flow. The maximum cable length from the 55 to the 8900 or 9900 depends on the 8900 or 9900 configuration. Refer to the 8900 or 9900 manual for complete information. Blue Jumper OFF = S L OUT S L 55 Frequency Out to other manufacturer's equipment If connecting the 55 Magmeter to a flow instrument from another manufacturer, 5 to VDC power must be provided to the 55. A 0 KΩ pull-up resistor (not supplied) must also be connected between terminals and. 55 Magmeter Not used Ground Frequency Out 5- VDC Install a pull-up resistor when connecting the 55 Magmeter to other manufacturer's flowmeters. Calibration and Software Configuration No calibration is necessary to begin using the 55. The application and performance settings are pre-set to meet the requirements of most applications. The 55 application and performance settings can be customized using the Signet -050 USB to Digital (S L) Configuration/ Diagnostic Tool and software. Refer to the Signet -050 USB-to-S L Configuration/Diagnostic Tool manual for details to adjust the following parameters: to 0 ma span: Factory setting is 0 to 5 m/s. Can be customized to any range. Noise Rejection Filter: Factory set for 60 Hz. Can be changed to 50 Hz. Low Flow Cutoff: Factory setting is 0.05 m/s. Can be customized to any velocity. Averaging Time: Factory setting is seconds. Can be customized from 0. seconds to 00 seconds. Sensitivity: Factory setting is 5% of full scale. Can be customized to any % of full scale. 55 Blind Magmeter 7

8 Calibration Data: s and Full Scale Current Values Plastic Installation Fittings: PVC Tees and Saddles Plastic Installation Fittings for Metric Pipes: Polypropylene True Union Tees and Wafers PVDF True Union Tees, PVC True Union Tees Pipe Size (In.) Fitting Gallons Liters in GPM in LPM Pipe Size (Metric) Fitting Gallons Liters in GPM in LPM SCH 80 PVC-U TEES FOR SCH 80 PVC PIPE ½ MPV8T ¾ MPV8T MPV8T ¼ MPV8T ½ MPV8T MPV8T SCH 80 PVC TEES FOR SCH 80 PVC PIPE ½ PV8T PV8T PV8T SCH 80 PVC TEES FOR SCH 80 CPVC PIPE ½ MCPV8T ¾ MCPV8T MCPV8T ¼ MCPV8T ½ MCPV8T MCPV8T SCH 80 PVC SADDLES FOR SCH 80 PVC PIPE PV8S ½ PV8S PV8S PV8S PV8S PV8S PV8S PV8S SCH 80 PVC SADDLES FOR SCH 0 PVC PIPE PV8S ½ PV8S PV8S PV8S PV8S PV8S PV8S PV8S POLYPROPYLENE FITTINGS (DIN/ISO, BS, ANSI) DN5 PPMT DN0 PPMT DN5 PPMT DN PPMT DN0 PPMT DN50 PPMT PVDF FITTINGS (DIN/ISO, BS, ANSI) DN5 SFMT DN0 SFMT DN5 SFMT DN SFMT DN0 SFMT DN50 SFMT PVC FITTINGS (DIN/ISO, BS, ANSI) DN5 PVMT DN0 PVMT DN5 PVMT DN PVMT DN0 PVMT DN50 PVMT Metal Installation Fittings Iron Saddles Pipe Size (In.) Fitting Gallons Liters in GPM in LPM SCH 80 IRON SADDLE ON SCH 80 PIPE IR8S ½ IR8S IR8S IR8S IR8S IR8S IR8S IR8S IR8S SCH 80 IRON SADDLE ON SCH 0 PIPE IR8S ½ IR8S IR8S IR8S IR8S IR8S IR8S IR8S IR8S Blind Magmeter

9 Calibration Data: s and Full Scale Current Values Metal Installation Fittings: Carbon Steel Tees and Weld-o-Lets Stainless Steel Tees and Weld-o-Lets, Galvanized Iron Tees Metal Installation Fittings: Bronze and Copper Tees and Brazolets Pipe Size (In.) Fitting Gallons Liters in GPM in LPM Pipe Size (In.) Fitting Gallons Liters in GPM in LPM CARBON STEEL TEES ON SCH 0 PIPE ½ CST ¾ CST CST ¼ CST ½ CST CST STAINLESS STEEL TEES ON SCH 0 PIPE ½ CRT ¾ CRT CRT ¼ CRT ½ CRT CRT STAINLESS STEEL WELDOLETS ON SCH 0 PIPE ½ CRW CRW CRW CRW CRW CRW CRW CRW CARBON STEEL WELDOLETS ON SCH 0 PIPE ½ CSW CSW CSW CSW CSW CSW CSW CSW BRONZE TEES ON SCH 0 PIPE BRT ¼ BRT ½ BRT BRT COPPER TEES FITTING ON COPPER PIPE SCH K ½ CUKT ¾ CUKT CUKT ¼ CUKT ½ CUKT CUKT COPPER TEES FITTING ON COPPER PIPE SCH L ½ CUKT ¾ CUKT CUKT ¼ CUKT ½ CUKT CUKT COPPER/BRONZE BRAZOLET ON SCH 0 PIPE ½ BRB BRB BRB BRB BRB BRB BRB BRB GALVANIZED IRON TEES ON SCH 0 PIPE IRT ¼ IRT ½ IRT IRT Blind Magmeter 9

10 Maintenance The 55 Magmeter requires very little maintenance. There are no user-serviceable components in the Magmeter. If the fluid contains deposits and solids that may coat the electrodes, a regular cleaning schedule is recommended. Do not use abrasive materials on the metal electrodes. Clean with soft cloth and mild detergent only. Use a cotton swab and mild detergent to remove deposits on the metal electrodes at the tip of the sensor. Environmental Recommendations: When used properly, this product presents no inherent danger to the environment. Please follow local ordinances when disposing of this or any product with electronic components. Troubleshooting Symptom Possible Cause Solution Output is erratic and unstable. Output is not 0 when flow is stopped. -0 ma current output is incorrect. Frequency output is inoperative Digital (S L) output is inoperative. Loop output is inoperative. Output is. ma Magmeter installed too close to upstream obstruction. Magmeter located in area exposed to air bubbles/pockets. Magmeter is installed in pipe backwards. Electrical noise is interfering with the measurement. Electrodes are coated with solids. Relocate the magmeter to have straight uninterrupted pipe upstream of the sensor for at least 0 x the pipe diameter. Eliminate air bubbles in the pipe. Remove the magmeter and reinstall with the flow direction arrow on the sensor body pointed DOWNSTREAM. Review the grounding of the magmeter and the pipe. Install adequate Earth ground to allow the Magmeter to operate properly. Carefully clean the electrodes. Refer to sensor manual for details. New sensor; metal surface not properly conditioned. Soak sensor overnight in fluid. Electrodes not adequately conditioned. Soak sensor overnight in fluid. Vibration or other movement in pipe causes Increase the Low Flow Cutoff. magmeter to detect flow. Electrical noise interference. Modify grounding to protect the Magmeter from interference. Defective Magmeter. Return to factory for service. Use -050 Setup tool to respan the Loop device not scaled same as Magmeter. Magmeter to match Loop device. Respan Loop device to match Magmeter. Range Jumper not placed correctly. Set Range Jumper correctly. Defective Magmeter. Return to factory for service 55 is wrong model. Frequency/S L model: -55-XX- Blue jumper not in correct position. Place blue jumper correctly. (Pg. ) Wiring is not correct. Check wiring, make corrections. (Pg. 7) Frequency input to other manufacturer's flow instrument does not have pull-up Install 0 kω resistor. (Pg. 7) resistor. Conductivity is less than 0 µs/cm (the fluid is too clean for Magmeter). Unsuitable application for Magmeter. Electronic component failure. Return 55 to factory Blind Magmeter

11 Flow Flow Troubleshooting Troubleshooting with the RED and BLUE LEDs Both Off: The power is off or the sensor is not connected. Solid Blue: The power is on, the pipe is full, but there is no flow in the pipe. Blinking Blue: Normal operation, blink rate is proportional to the flow rate. Alternating Red-Blue: Empty pipe indication (electrodes are not wet). Blinking Red: System errors (electrical noise interference). Solid Red: Instrument error (defective electronics component). D6 D7 If the 55 detects an empty pipe: Frequency output will be locked to 0 Hz if electrodes are not wet. Digital (S L) output will be locked to 0 if electrodes are not wet. to 0 ma will be locked to ma if electrodes are not wet. Blue and red LEDs will blink alternately if electrodes are not wet. If the 55 detects REVERSE FLOW: Frequency out cannot distinguish reverse flow from forward flow. The output will be the absolute value. With Digital (S L) output, reverse flow results in 0 flow rate displayed on 8900 or with negative numbers on the ma output can be spanned into negative flow range using the -050 USB Setup Tool and software. (Page 7) (example: -0 ma = 00 to +00 GPM). Ordering Information Accessories and Replacement Parts Mfr. Part No. Code Description O-Rings O-ring, FPM ( required per sensor) O-ring, EPR (EPDM) ( required per sensor) O-ring, FFPM ( required per sensor) Replacement Transducers -55-P PP/6L SS, DN5 to DN00 (½ to in.) pipe -55-P PP/6L SS, DN5 to DN00 (5 to 8 in.) pipe -55-P PP/6L SS, DN50 to DN900 (0 to 6 in.) pipe -55-T PVDF/Titanium, DN5 to DN00 (½ to in.) pipe -55-T PVDF/Titanium, DN5 to DN00 (5 to 8 in.) pipe -55-T PVDF/Titanium, DN50 to DN900 (0 to 6 in.) pipe -55-V PVDF/Hastelloy-C, DN5 to DN00 (½ to in.) pipe -55-V PVDF/Hastelloy-C, DN5 to DN00 (5 to 8 in.) pipe -55-V PVDF/Hastelloy-C, DN50 to DN900 (0 to 6 in.) pipe Replacement Electronics Module Magmeter electronics, frequency or digital (S L) output Magmeter electronics, to 0 ma output Magmeter display electronics, frequency or digital (S L) output, with relays Magmeter display electronics, to 0 ma output w/relays Magmeter display electronics, frequency or digital (S L) output Magmeter display electronics, to 0 ma output Other P Sensor plug, Polypropylene VDC Power Supply, 0. A, 0W VDC Power Supply,.0 A, W VDC Power Supply,.7 A, 0W VDC Power Supply,.5 A, 60W VDC Power Supply,.0 A, 96W Retaining Nut Replacement Kit, NPT, Valox Retaining Nut Replacement Kit, NPT, PP Retaining Nut Replacement Kit, NPT, PVDF Liquid-tight connector kit, set, ½ in. NPT USB to digital (S L) Configuration/Diagnostic tool 55 Blind Magmeter

12 Ordering Information to 0 ma output Mfr. Part No. Code Description -55-P DN5 to DN00 (½ to in.), Polypropylene and 6L SS -55-T DN5 to DN00 (½ to in.), PVDF and Titanium -55-V DN5 to DN00 (½ to in.), PVDF and Hastelloy-C -55-P DN5 to DN00 (5 to 8 in.), Polypropylene and 6L SS -55-T DN5 to DN00 (5 to 8 in.), PVDF and Titanium -55-V DN5 to DN00 (5 to 8 in.), PVDF and Hastelloy-C -55-P DN50 to DN900 (0 to 6 in.), Polypropylene and 6L SS -55-T DN50 to DN900 (0 to 6 in.), PVDF and Titanium -55-V DN50 to DN900 (0 to 6 in.), PVDF and Hastelloy-C Frequency or Digital (S L) output programmable open collector Mfr. Part No. Code Description -55-P DN5 to DN00 (½ to in.), Polypropylene and 6L SS -55-T DN5 to DN00 (½ to in.), PVDF and Titanium -55-V DN5 to DN00 (½ to in.), PVDF and Hastelloy-C -55-P DN5 to DN00 (5 to 8 in.), Polypropylene and 6L SS -55-T DN5 to DN00 (5 to 8 in.), PVDF and Titanium -55-V DN5 to DN00 (5 to 8 in.), PVDF and Hastelloy-C -55-P DN50 to DN900 (0 to 6 in.), Polypropylene and 6L SS -55-T DN50 to DN900 (0 to 6 in.), PVDF and Titanium -55-V DN50 to DN900 (0 to 6 in.), PVDF and Hastelloy-C Georg Fischer Signet LLC, 0 Aero Jet Avenue, El Monte, CA U.S.A. Tel. (66) Fax (66) For Worldwide Sales and Service, visit our website: Or call (in the U.S.): (800) For the most up-to-date information, please refer to our website at Rev M 0/ English Georg Fischer Signet LLC 0

* * Rev /18 Operating Instructions

* * Rev /18 Operating Instructions English Signet 255 Blind Magmeter *-2552.090* -255.090 Rev. 6 07/8 Operating Instructions Description The Signet 255 Magmeter is an insertion-style magnetic flow sensor. The patented sensor design is available

More information

* * Rev. 9 01/18 Product Manual

* * Rev. 9 01/18 Product Manual English Signet 2760 DryLoc ph/orp Preamplifier *3-2760.090* 3-2760.090 Rev. 9 01/18 Product Manual Description The Signet 2760 ph/orp Preamplifiers with DryLoc connectors are part of Signet's growing line

More information

Signet 515/2536 Rotor-X Flow Sensors * * Operating Instructions. English. Description Rev. X 05/17

Signet 515/2536 Rotor-X Flow Sensors * * Operating Instructions. English. Description Rev. X 05/17 English Signet 515/2536 Rotor-X Flow Sensors *3-0515.090* 3-0515.090 Rev. X 05/17 Operating Instructions 515 Sensor (with red cap) 2536 Sensor (with blue cap) 8510 Integral Sensor 8512 Integral Sensor

More information

* * Rev. F 03/16 Operating Instructions

* * Rev. F 03/16 Operating Instructions English Signet 2552 Metal Magmeter *3-2552.090* 3-2552.090 Rev. F 03/16 Operating Instructions 3-2552-2 3-2552-3 Description The Signet 2552 Metal Magmeter from Georg Fischer features all-stainless steel

More information

Signet 2551 Magmeter Flow Sensor

Signet 2551 Magmeter Flow Sensor Signet 2551 Magmeter Flow Sensor Available in a variety of wetted materials and ideal for pipe sizes up to DN900 (36 in.) Features Test certificate included for -X0, -X1 Patented Magmeter technology No

More information

Signet 2552 Metal Magmeter

Signet 2552 Metal Magmeter Signet 2552 Metal Magmeter *3-2552.090* 3-2552.090 Rev E 07/10 English English SAFETY INSTRUCTIONS 1. Depressurize and vent systems without Hot-tap valve prior to installation or removal. 2. Confirm chemical

More information

Signet 2552 Metal Magmeter

Signet 2552 Metal Magmeter Signet 2552 Metal Magmeter *3-2552.090* 3-2552.090 Rev D 06/08 English English SAFETY INSTRUCTIONS 1. Depressurize and vent systems without Hot-tap valve prior to installation or removal. 2. Confi rm chemical

More information

* * Signet 2450 Pressure Sensor. Product Manual. English. Description. Dimensions Rev /18

* * Signet 2450 Pressure Sensor. Product Manual. English. Description. Dimensions Rev /18 English Signet 2450 Pressure Sensor *32450.0901* 32450.0901 Rev. 13 03/18 Product Manual Description The 2450 Pressure Sensor has a onepiece injection molded PVDF body and ceramic diaphragm for superior

More information

Signet 8150 Flow Totalizer

Signet 8150 Flow Totalizer English Signet 8150 Flow Totalizer *3-8150.090-1* 3-8150.090-1 Rev. K 9/14 English Operating Instructions Description The Signet 8150 Flow Totalizer is a battery-powered instrument capable of providing

More information

SIGNET 7002 Vortex Flow Sensor ENGLISH

SIGNET 7002 Vortex Flow Sensor ENGLISH SIGNET 7002 Vortex Flow Sensor ENGLISH 3-7002.090 C-7/02 English SAFETY INSTRUCTIONS 1. Do not remove from pressurized lines. 2. Never install sensor without O-Rings. 3. Confirm chemical compatibility

More information

Installation Fittings

Installation Fittings PVC TEES SCH 80 - Fitting only Part No. Code Size L H i.d. PV8T005F 159 000 527 0.50 in. 3.75 3.6 0.85 PV8T007F 159 000 529 0.75 in. 3.75 3.8 1.06 PV8T010F 159 000 531 1.00 in. 4.26 4.0 1.33 PV8T012F 159

More information

Signet 2760 DryLoc ph/orp Preamplifier

Signet 2760 DryLoc ph/orp Preamplifier Signet 2760 DryLoc ph/orp Preamplifier *3-2760.090* 3-2760.090 Rev. H 05/11 English English SAFETY INSTRUCTIONS 1. Depressurize and vent system prior to installation or removal. 2. Confi rm chemical compatibility

More information

Signet 2552 Magmeter. English * * Specifications. Safe to operate Hot-tap

Signet 2552 Magmeter. English * * Specifications. Safe to operate Hot-tap Signet 2552 Magmeter *3-2552.090* 3-2552.090 Rev. A 11/06 English SAFETY INSTRUCTIONS 1. Depressurize and vent systems without Hot-tap valve prior to installation or removal. 2. Confi rm chemical compatibility

More information

SIGNET 2760 DryLoc ph/orp Preamplifier

SIGNET 2760 DryLoc ph/orp Preamplifier SIGNET 2760 DryLoc ph/orp Preamplifier 3-2760.090 3-2760.090 (A-3/04) English SAFETY INSTRUCTIONS 1. Depressurize and vent system prior to installation or removal. 2. Confirm chemical compatibility before

More information

Signet 7000/7001 Vortex Flow Sensors * *

Signet 7000/7001 Vortex Flow Sensors * * DN X DN X DN X DN X DN X DN X DN X Signet 7000/7001 Vortex Flow Sensors *3-7000.090* 3-7000.090 Rev. F 10/05 English English 1. Mounting Location... 1 2. Installation... 1 3. Wiring Preparation... 2 4.

More information

Signet 2536 Rotor-X Paddlewheel Flow Sensors

Signet 2536 Rotor-X Paddlewheel Flow Sensors Signet 2536 Rotor-X Paddlewheel Flow s Features Operating range 0.1 to 6 m/s (0.3 to 20 ft/s) Wide turndown ratio of 66:1 Open-collector output Highly repeatable output Simple, economical design PVC (gray

More information

SIGNET Vortex Flow Sensors ENGLISH

SIGNET Vortex Flow Sensors ENGLISH DN X DN X DN X DN X DN X DN X DN X SIGNET Vortex Flow Sensors ENGLISH 37000.090 C12/00 English 1. Mounting Location... 1 2. Installation... 1 3. Wiring Preparation... 2 4. Wiring Options Frequency Output

More information

Signet 515 Rotor-X Paddlewheel Flow Sensors

Signet 515 Rotor-X Paddlewheel Flow Sensors Signet 515 Rotor-X Paddlewheel Flow Sensors Features Operating range 0.3 to 6 m/s (1 to 20 ft/s) Wide turndown ratio of 20:1 Highly repeatable output Simple, economical design Installs into pipe sizes

More information

Signet 515 Rotor-X Paddlewheel Flow Sensors

Signet 515 Rotor-X Paddlewheel Flow Sensors Signet 515 Rotor-X Paddlewheel Flow Sensors Features Operating range 0.3 to 6 m/s (1 to 20 ft/s) Wide turndown ratio of 20:1 Highly repeatable output Simple, economical design Installs into pipe sizes

More information

SIGNET 2750 ph/orp Sensor ENGLISH

SIGNET 2750 ph/orp Sensor ENGLISH ENGLISH 3-2750.090 B-8/01 English SAFETY INSTRUCTIONS FOR IN-LINE ELECTRODE INSTALLATION 1. Do not remove from pressurized lines. 2. Do not exceed maximum temperature/pressure specifications. 3. Wear safety

More information

User s Guide. FMG-3000 SERIES Blind Version. Magmeter. Shop online at ISO 9001 ISO 9002

User s Guide. FMG-3000 SERIES Blind Version. Magmeter. Shop online at ISO 9001 ISO 9002 User s Guide Shop online at TM omega.com www.omega.com e-mail: http://omegamanual.info For latest information and product manual visit www.omegamanual.info. ISO 9001 CERTIFIED CORPORATE QUALITY STAMFORD,

More information

Pipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations.

Pipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations. Signet 50 High Performance Flow Sensor English *3-50.090* 3-50.090 Rev. F 11/1 English For the most up-to-date information, please refer to our website at www.gfsignet.com SAFETY INSTRUCTIONS 1. Do not

More information

Signet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems with PVDF Sensor

Signet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems with PVDF Sensor Signet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems with PVDF Sensor Features Test certificate supplied with all sensors Universal Mount Custom cell constant programmed into the

More information

Pipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations.

Pipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations. Signet 50 High Performance Flow Sensor English *3-50.090* 3-50.090 C 05/06 English SAFETY INSTRUCTIONS 1. Do not remove from pressurized lines.. Do not exceed maximum temperature/pressure specifi cations.

More information

Signet 2517 Brass Paddlewheel Flow Sensor * *

Signet 2517 Brass Paddlewheel Flow Sensor * * Signet 2517 Brass Paddlewheel Flow Sensor -250.090 English -2517.090 Rev. F 11/06 English SAFETY INSTRUCTIONS 1. Do not remove from pressurized lines. 2. Do not exceed maximum temperature/pressure specifi

More information

Chapter Page. 1 Introduction Description 1

Chapter Page. 1 Introduction Description 1 Chapter Page 1 Introduction 1 1.1 Description 1 Table of Contents 2 Calibration 3 2.1 Wet Calibration 3 2.2 Calibration Procedure 4 2.3 Installing Optional Display Board 5 2.4 Display Board Range Adjustment

More information

Pipe fittings MUST be installed by a certified welder only. +GF+ SIGNET will not assume liability of any kind for improper fitting installations.

Pipe fittings MUST be installed by a certified welder only. +GF+ SIGNET will not assume liability of any kind for improper fitting installations. +GF+ SIGNET 0 High Performance Flow Sensor (English) -0.090- F-/99 English SAFETY INSTRUCTIONS. Do not remove from pressurized lines.. Do not exceed maximum temperature/pressure specifications.. Do not

More information

SIGNET Installation Fittings

SIGNET Installation Fittings Fiberglass Glue-on Saddles Part no. ode Size FPS030 159 000 441 3.00 in. 5.9 4.5 3.50 1.44 FPS040 159 000 442 4.00 in. 8.0 4.5 4.50 1.44 FPS060 159 000 443 6.00 in. 8.0 6.5 6.62 2.25 FPS080 198 801 417

More information

Signet Pressure Transmitter

Signet Pressure Transmitter Signet 80 Pressure 80.090 80.090 Rev. J 0/ English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury. Contents. Installation.

More information

Signet Pressure Transmitter

Signet Pressure Transmitter Signet 8450 Pressure English 8450.090 8450.090 Rev. G /06 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury. Contents

More information

FLOWX3 F3.60M.S Insertion Magmeter

FLOWX3 F3.60M.S Insertion Magmeter FLOWX3 F3.60M.S Insertion Magmeter The FLOWX3 F3.60M.S Insertion Magmeters are suitable to measure flowrate in both metal and thermoplastic pipelines. No moving mechanical parts and the high quality materials

More information

Signet Conductivity/Resistivity Electrodes

Signet Conductivity/Resistivity Electrodes Signet 2818-2823 Conductivity/Resistivity Electrodes 2818 2819 2820 2821 2822 2823 Sanitary Features Standard process connections - Polypro - SS on 10 and 20 cell - Tri-clamp 1-1½ in., 2 in. - Opt. ½ in.

More information

SIGNET Temperature Transmitter

SIGNET Temperature Transmitter SIGNET 83501 Temperature *38350.0901* English 38350.0901 Rev. G 3/06 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury.

More information

Signet Temperature Transmitter

Signet Temperature Transmitter Signet 80 Temperature English 80.090 80.090 Rev. G /0 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury. Contents.

More information

+GF+ SIGNET Conductivity Transmitter. Instruction Manual GEORGE FISCHER +GF+

+GF+ SIGNET Conductivity Transmitter. Instruction Manual GEORGE FISCHER +GF+ +GF+ SIGNET 3-8800 Conductivity Transmitter Instruction Manual GEORGE FISCHER +GF+ SAFETY INSTRUCTIONS 1. Do not remove from pressurized lines. 2. Do not exceed maximum temperature/pressure specifications.

More information

FLS F6.60 MAGMETER FLOW SENSOR INSERTION FLOW SENSORS APPLICATIONS MAIN FEATURES

FLS F6.60 MAGMETER FLOW SENSOR INSERTION FLOW SENSORS APPLICATIONS MAIN FEATURES FLS F6.60 MAGMETER FLOW SENSOR The new F6.60 and F6.63 are flow meters without moving mechanical parts which can be applied for the measurement of dirty liquids so long as they are conductive and homogeneous.

More information

FMK-2536, FP-5100, FP-5300,FP-5600, FP-8500, FP-8500A

FMK-2536, FP-5100, FP-5300,FP-5600, FP-8500, FP-8500A User s Guide Shop online at omega.com SM e-mail: info@omega.com For latest product manuals: www.omegamanual.info SERIES: FMK-2536, FP-5100, FP-5300,FP-5600, FP-8500, FP-8500A Paddlewheel Flow Sensors omega.com

More information

Hydro-Flow 2300 Fixed Insertion Vortex Flow Meter

Hydro-Flow 2300 Fixed Insertion Vortex Flow Meter Hydro-Flow 2300 Fixed Insertion Vortex Flow Meter Description The Hydro-Flow Model 2300 insertion vortex flow meter was designed specifically for water flow measurement, containing no moving parts like

More information

Signet ph/orp Electrodes

Signet ph/orp Electrodes Signet 2734-2736 ph/orp Electrodes Compatible with Signet 8900/9900 Instruments Features Patented reference design for exceptional performance * Mounts in Signet standard fittings from DN15 to DN100 (½

More information

Hydro-Flow 2200 Fixed Insertion Vortex Flow Meter

Hydro-Flow 2200 Fixed Insertion Vortex Flow Meter A trademark of Spirax Sarco, Inc. Hydro-Flow 2200 Fixed Insertion Vortex Flow Meter Description The Hydro-Flow Model 2200 fixed insertion vortex flow meter was designed specifically for water flow measurement,

More information

User s Guide FMG-550 SERIES OMEGAMAG. Shop online at omega.com SM For latest product manuals:

User s Guide FMG-550 SERIES OMEGAMAG. Shop online at omega.com SM   For latest product manuals: User s Guide Shop online at omega.com SM e-mail: info@omega.com For latest product manuals: www.omegamanual.info FMG-550 SERIES OMEGAMAG omega.com info@omega.com U.S.A. Headquarters: Servicing North America:

More information

Signet 3719 ph/orp Wet-Tap

Signet 3719 ph/orp Wet-Tap Signet 3719 ph/orp Wet-Tap *3-3719.090* 3-3719.090 Rev H 09/07 English Do not exceed maximum temperature/pressure specifications. Wear safety goggles or face shield during installation/service. Do not

More information

Signet 3719 ph/orp Wet-Tap Assembly

Signet 3719 ph/orp Wet-Tap Assembly Signet 3719 ph/p Wet-Tap Assembly Features Electrode removal without process shutdown Space saving 45 mm (1.75 in.) short-stroke design Sealed pneumatic dampening for smooth and safe operation SafeLoc

More information

ARCHIVED. EX80 Series. (Includes Dates 6/28/05 to 10/06) EX81 EX82

ARCHIVED. EX80 Series. (Includes Dates 6/28/05 to 10/06) EX81 EX82 E X S E R I E S E l e c t r o m a g n e t i C F l o w s e n s o r i n s t r u c t i o n s EX Series Electromagnetic FLOW SENSOR instructions EX EX The Leader in Flow Meter Value. Table of Contents General

More information

Signet ph/orp Electrodes

Signet ph/orp Electrodes Signet 2724-2726 ph/orp Electrodes Compatible with ALL Signet ph/orp Instruments Features Patented reference design for exceptional performance * Mounts in Signet standard fittings from DN15 to DN100 (½

More information

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide 11451 Belcher Road South, Largo, FL 33773 USA Tel +1 (727) 447-6140 Fax +1 (727) 442-5699 1054-7 / 34405 www.onicon.com sales@onicon.com

More information

EX80 Series EX81 EX82. E X 8 0 S E R I E S E l e c t r o m a g n e t i C F l o w s e n s o r i n s t r u c t i o n s. The Leader in Flow Meter Value.

EX80 Series EX81 EX82. E X 8 0 S E R I E S E l e c t r o m a g n e t i C F l o w s e n s o r i n s t r u c t i o n s. The Leader in Flow Meter Value. E X S E R I E S E l e c t r o m a g n e t i C F l o w s e n s o r i n s t r u c t i o n s EX Series Electromagnetic FLOW SENSOR instructions EX EX The Leader in Flow Meter Value. Table of Contents General

More information

Signet Conductivity/Resistivity Electrodes

Signet Conductivity/Resistivity Electrodes Signet 2818-2823 Conductivity/Resistivity Electrodes 2818 2819 2820 2821 2822 2823 Sanitary Features Standard process connections - Polypro - SS on 10 and 20 cell - Tri-clamp 1-1½ in., 2 - Opt. ½ in. NPT

More information

Signet DryLoc ph/orp Electrodes

Signet DryLoc ph/orp Electrodes Signet 2774-2777 DryLoc ph/orp Electrodes Features Patented DryLoc connector with gold plated contacts* Special design allows for installation at any angle, even inverted or horizontal Quick temperature

More information

Hydro-Flow Model 2300 Installation and Operation Guide B

Hydro-Flow Model 2300 Installation and Operation Guide B Hydro-Flow Model 2300 Installation and Operation Guide 5700508-B Contents: Understanding and Identifying Your Flow Meter 1 Installing Your Flow Meter 3 Electrical Connections.. 7 Mechanical and Electrical

More information

Paddle-wheel flow controller for On/Off control

Paddle-wheel flow controller for On/Off control Paddle-wheel flow controller for On/Off control Type 8032 can be combined with... Indication, monitoring, transmitting and On/Off control in one device Programmable outputs (transistor or relay) Automatic-calibration:

More information

From. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951)

From. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951) SPI Mag MODEL 282L SINGLE POINT INSERTION ELECTROMAGNETIC FLOW METER 2 SENSOR SUBMITTAL PACKAGE From McCROMETER, INC. 3255 WEST STETSON AVENUE HEMET, CA 92545 Phone (951) 652-6811 Toll Free (800) 220-2279

More information

Insertion magnetic inductive flowmeter

Insertion magnetic inductive flowmeter Insertion magnetic inductive flowmeter Sensor without moving parts Flowmeter with On/Off control Application related calibration by Teach-In function Clean in place (CIP) FDA-compliant materials Type 8041

More information

2100 Turbine Flow Sensor

2100 Turbine Flow Sensor 200 Turbine Flow Sensor Description Engineered specifically for small pipe diameter applications, the Signet 200 Turbine Flow Sensor provides accurate readings in two flow ranges: 0.3 to 3.8 lpm and 3

More information

Signet V(D) to V(D) PVDF Conductivity Electrodes

Signet V(D) to V(D) PVDF Conductivity Electrodes Signet 2839-1V(D) to 2842-1V(D) PVDF Conductivity Electrodes Features ± 2% accuracy - Custom calibration certificate provided Dual-threaded Compact electrode length for easy in-line installation in small

More information

Signet ph/orp Electrodes

Signet ph/orp Electrodes Signet 2724-2726 ph/orp Electrodes Compatible with ALL Signet ph/orp Instruments Features Flat Glass Protected Bulb Patented reference design for exceptional performance * Mounts in Signet standard fittings

More information

INSERTION flow sensor for continuous flow measurement

INSERTION flow sensor for continuous flow measurement INSERTION flow sensor for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN)

More information

Signet 2760 DryLoc ph/orp Preamplifiers & Connectors

Signet 2760 DryLoc ph/orp Preamplifiers & Connectors Signet 2760 DryLoc ph/orp Preamplifiers & Connectors Features In-line integral mount and submersible installation versions Automatic temperature compensation Auto configuration for ph or ORP operation

More information

+GF+ SIGNET 2550 Insertion Magmeter

+GF+ SIGNET 2550 Insertion Magmeter +GF+ SIGNET 2550 Insertion Magmeter Instruction Manual GEORGE FISCHER +GF+ Important Safety Information! CAUTION: Do not remove from pressurized lines! Do not remove safety ring from sensor. Unit may become

More information

Paddle-wheel flow controller for On/Off control

Paddle-wheel flow controller for On/Off control Paddle-wheel flow controller for On/Off control Type 803 can be combined with... Indication, monitoring, transmitting and On/Off control in one device Programmable s (transistor or relay) Automatic-calibration:

More information

Signet ph/orp Transmitter

Signet ph/orp Transmitter Signet 87501 ph/orp English *38750.0901* 38750.0901 Rev. F 3/06 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury.

More information

EX80-Series ELECTROMAGNETIC FLOW SENSOR INSTRUCTIONS EX81 EX82 EX :2008 ISO CERTIFIED COMPANY

EX80-Series ELECTROMAGNETIC FLOW SENSOR INSTRUCTIONS EX81 EX82 EX :2008 ISO CERTIFIED COMPANY EX80- SERIES ELECTROMAGNETIC FLOW SENSOR INSTRUCTIONS EX80-Series ELECTROMAGNETIC FLOW SENSOR INSTRUCTIONS EX81 EX82 EX83 9 001:2008 ISO CERTIFIED COMPANY TABLE OF CONTENTS General Information Features,

More information

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004 U00X ULTRASONIC LEVEL SWITCH INSTALLATION AND OPERATIONS MANUAL Ultrasonic Liquid Level Switches For Non-Hazardous Locations For Models: U002, U003 & U004 READ THIS MANUAL PRIOR TO INSTALLATION This manual

More information

display on the wall or in a panel away from the inline sensor SE30 for easy meter reading.

display on the wall or in a panel away from the inline sensor SE30 for easy meter reading. Analogue Flow Rate Indicator, DN 15...; PN 1...16 Advantages / Benefits Reduced costs of ownership up to 6% Economic integration in pipe systems without any additional piping Shows flow rate with a large

More information

EX100/200-Series INSERTION MAGNETIC FLOW METER INSTRUCTIONS EX110 EX210 EX150 EX :2008 ISO CERTIFIED COMPANY

EX100/200-Series INSERTION MAGNETIC FLOW METER INSTRUCTIONS EX110 EX210 EX150 EX :2008 ISO CERTIFIED COMPANY EX100/200-SERIES INSERTION MAGNETIC FLOW METER INSTRUCTIONS EX100/200-Series INSERTION MAGNETIC FLOW METER INSTRUCTIONS EX110 EX210 EX150 EX250 9 001:2008 ISO CERTIFIED COMPANY TABLE OF CONTENTS General

More information

Appendix. Clearance. Skewed profiles. Application Schematics

Appendix. Clearance. Skewed profiles. Application Schematics Appendix Application Schematics The purpose of the application schematics is to show different applications and the best sensor location for a particular application. Clearance Because the sensor will

More information

Hydro-Flow Model 2200 Installation and Operation Guide B

Hydro-Flow Model 2200 Installation and Operation Guide B Hydro-Flow Model 2200 Installation and Operation Guide 5700507-B Contents: Understanding and Identifying Your Flow Meter 1 Installing Your Flow Meter 3 Making Electrical Connections. 7 Mechanical and Electrical

More information

INSERTION flowmeter with paddle wheel, ELEMENT design

INSERTION flowmeter with paddle wheel, ELEMENT design INSERTION flowmeter with paddle wheel, design Up to PN, size of measurement pipes: DN to DN400 Configurable outputs: one or two transistor output(s) and single or dual 4... ma analog output(s) Removable

More information

Hydro-Flow Model 3100

Hydro-Flow Model 3100 Hydro-Flow Model 3100 Installation and Operation Guide installation and operation guide Contents: Understanding Your Flow Meter... 1 Identifying Your Flow Meter...2 Installing Your Flow Meter...3,4 Making

More information

Hydro-Flow Model 2200 Fixed Insertion Vortex Flowmeter Installation and Operation Manual

Hydro-Flow Model 2200 Fixed Insertion Vortex Flowmeter Installation and Operation Manual Hydro-Flow Model 00 Fixed Insertion Vortex Flowmeter Installation and Operation Manual Table of Contents Model and Suffix Codes. Theory and Identification.. Installation Guidelines 4 Mechanical Drawing:

More information

Signet DryLoc ph/orp Electrodes

Signet DryLoc ph/orp Electrodes Signet 2774-2777 DryLoc ph/orp Electrodes Features Patented DryLoc connector with gold plated contacts* Special design allows for installation at any angle, even inverted or horizontal Quick temperature

More information

Octave Water Meter Installation Manual

Octave Water Meter Installation Manual Octave Water Meter Installation Manual 1.0 Notes For proper flow measurements, the OCTAVE s measuring tube should be completely full at all times. Non-wetted sensors show loss of signal. Though this will

More information

Signet Measurement and Instrumentation

Signet Measurement and Instrumentation F Piping Systems Signet Measurement and Instrumentation Price List effective January 1, 2015 Conveyance Pipe, Fittings, Joining Technology // PVC/CPVC // PPro-Seal PP // PROEF PP // SYEF PVDF // Contain-It

More information

AG2000 IRRIGATION MAGMETER INSTRUCTIONS

AG2000 IRRIGATION MAGMETER INSTRUCTIONS AG2000 IRRIGATION MAGMETER INSTRUCTIONS AG2000 IRRIGATION MAGMETER INSTRUCTIONS FEATURES Rate and total indicator Powder-coated diecast-aluminum electronics housing Cross-drilled screws (2) for tamper-evidence

More information

Hydro-Flow Model 3100 Retractable Insertion Vortex Flowmeter Installation and Operation Manual

Hydro-Flow Model 3100 Retractable Insertion Vortex Flowmeter Installation and Operation Manual Hydro-Flow Model 00 Retractable Insertion Vortex Flowmeter Installation and Operation Manual Table of Contents Model and Suffix Codes. Theory and Identification.. Installation Guidelines Mechanical Drawing:

More information

SIGNET 3719 ph/orp Wet-Tap

SIGNET 3719 ph/orp Wet-Tap ENGLISH 3-3719.090 B-6/02 English Do not exceed maximum temperature/pressure specifications. Wear safety goggles or face shield during installation/service. Do not attempt to disassemble the retraction

More information

Installation and Operating Manual

Installation and Operating Manual Model u002 & u003 Installation and Operating Manual Ultrasonic Level Switch 60 Great Hill Road Naugatuck, CT 06770 ph: 203-729-6434 fax: 203-729-6696 www.innovativesensing.com Read this Manual Before Installing

More information

CRICKET Alphasonic Level Transmitter Model LA12 Owner s Manual

CRICKET Alphasonic Level Transmitter Model LA12 Owner s Manual Warranty, Service and Repair To register your product with the manufacturer, fill out the enclosed warranty card and return it immediately to: FLOWLINE Inc. 10500 Humbolt Street Los Alamitos, CA 90720

More information

Measurement and Instrumentation

Measurement and Instrumentation 15 Measurement and Instrumentation Use the postcard included in this handbook or call (800) 854-4090 to order the complete Instrumentation Catalog or visit www.gfsignet.com for detailed product information.

More information

GF Signet. Measurement & Control Sensors. Signet Price List 1st Aug 2011 Rev 0.0

GF Signet. Measurement & Control Sensors. Signet Price List 1st Aug 2011 Rev 0.0 GF Signet Measurement & Control Sensors Sensors and Transmitters: Flow ph Conductivity ORP Level Pressure Temperature Turbidity Chlorine Installation fittings Power supplies Calibration solutions Accessories

More information

Low Profile Insertion Vortex

Low Profile Insertion Vortex Low Profile Insertion Vortex Product Features The same insertion meter can measure Steam, Gases or Liquids. Standardize on an insertion bar that can measure line sizes 2 24 Heavy Duty & Maintenance Free

More information

WMX-series MUNICIPAL/INDUSTRIAL MAGMETER INSTRUCTIONS

WMX-series MUNICIPAL/INDUSTRIAL MAGMETER INSTRUCTIONS -series MUNICIPAL/INDUSTRIAL MAGMETER INSTRUCTIONS -SERIES MUNICIPAL/INDUSTRIAL MAGMETER INSTRUCTIONS 101 104 The Leader in Flow Meter Value Table of Contents General Information General Information,

More information

Hot Tap Insertion Vortex

Hot Tap Insertion Vortex Hot Tap Insertion Vortex Product Features The same insertion meter can measure Steam, Gases or Liquids. Standardize on an insertion bar that can measure line sizes 2 48 Heavy Duty & Maintenance Free Design

More information

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE 2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE For Diaphragm Dosing Pumps FEM 1.02_.55 / FEM 1.09_.55 Controller board package, without pump: ID 160536 Operating and Installation Manual It is important to

More information

Vortex Plate. Model VP General Specification. Product Features

Vortex Plate. Model VP General Specification. Product Features Vortex Plate Product Features Our Inline meters can measure Steam, Gases or Liquids. Heavy Duty & Maintenance Free Design C&C Machined from one piece of solid stainless steel Absolutely NO o-rings or seals

More information

LEVEL AND FLOW MEASUREMENT WS131 FLOW METER USER MANUAL.

LEVEL AND FLOW MEASUREMENT WS131 FLOW METER USER MANUAL. LEVEL AND FLOW MEASUREMENT WS131 FLOW METER USER MANUAL www.enoscientific.com Eno Scientific PO Box 1586 Hillsborough, NC 27278 USA www.enoscientific.com 910-778-2660 Copyright Notice Copyright 2015 Eno

More information

PE202. Low Flow Magmeter Instructions. Precision Flow Measurement An ONICON Brand PROUDLY MADE IN THE USA

PE202. Low Flow Magmeter Instructions. Precision Flow Measurement An ONICON Brand PROUDLY MADE IN THE USA PE202 Low Flow Magmeter Instructions Precision Flow Measurement An ONICON Brand PROUDLY MADE IN THE USA ISO 9001:2008 Certified Company TABLE OF CONTENTS General Information General Information...Page

More information

Corrosion Resistant and Ultra-Pure Rotameters for Accurate Measurement of Liquids and Gases

Corrosion Resistant and Ultra-Pure Rotameters for Accurate Measurement of Liquids and Gases Corrosion Resistant and Ultra-Pure Rotameters for Accurate Measurement of Liquids and Gases Rotameters Markets/Applications George Fischer rotameters are ideally suited for a multitude of corrosive and

More information

Model FVP General Specification. Flanged Vortex Plate. Product Features

Model FVP General Specification. Flanged Vortex Plate. Product Features Flanged Vortex Plate Product Features Our Inline meters can measure Steam, Gases or Liquids. Measures two times lower than any other Vortex Meter. Heavy Duty & Maintenance Free Design C&C Machined from

More information

Insertion turbine INSTRUCTION SHEET. TECHNICAL PRODUCT

Insertion turbine INSTRUCTION SHEET.   TECHNICAL PRODUCT TECHNICAL PRODUCT INSTRUCTION SHEET Insertion turbine OVERVIEW These insertion flow transducers provide a cost effective and simple means of measuring the flow of a wide range of low viscosity liquids.

More information

M-3025CB-AV Fuel Pump

M-3025CB-AV Fuel Pump SAVE THESE INSTRUCTIONS M-3025CB-AV Fuel Pump Owner s Manual TABLE OF CONTENTS General Information... 2 Safety Instructions... 2 Installation... 3 Operation... 4 Maintenance... 4 Repair... 5 Troubleshooting...

More information

ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products Rev PK KMS501W & KMS502F- TW. Electromagnetic TRADEWASTE Flowmeters FEATURES:

ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products Rev PK KMS501W & KMS502F- TW. Electromagnetic TRADEWASTE Flowmeters FEATURES: KMS501W & KMS502F- TW FEATURES: Fitted with Sydney Water Tradewaste plugs (Sampler and ma outputs). For waste water, bore water and irrigation ( upto 10% solids). Unsurpassed accuracy to ±0.5% 0.5 m/s

More information

Digital ph transmitter

Digital ph transmitter Digital ph transmitter Compact, remote versions for DN 15 to 200 Fully programmable ph transmitter functions for all kinds of ph-measurement tasks Large range of process connections with various fittings

More information

TX80-Series FLOW SENSOR INSTRUCTIONS TX81 TX :2008 ISO CERTIFIED COMPANY TX80-SERIES FLOW SENSOR INSTRUCTIONS

TX80-Series FLOW SENSOR INSTRUCTIONS TX81 TX :2008 ISO CERTIFIED COMPANY TX80-SERIES FLOW SENSOR INSTRUCTIONS TX80-SERIES FLOW SENSOR INSTRUCTIONS TX80-Series FLOW SENSOR INSTRUCTIONS TX81 TX82 9 001:2008 ISO CERTIFIED COMPANY TABLE OF CONTENTS General Information Specifications, Features...Page 1 Installation

More information

TX800-Series FLOW SENSOR INSTRUCTIONS. TX81x TX82x 9 001:2008 ISO CERTIFIED COMPANY TX800-SERIES FLOW SENSOR INSTRUCTIONS

TX800-Series FLOW SENSOR INSTRUCTIONS. TX81x TX82x 9 001:2008 ISO CERTIFIED COMPANY TX800-SERIES FLOW SENSOR INSTRUCTIONS TX800-SERIES FLOW SENSOR INSTRUCTIONS TX800-Series FLOW SENSOR INSTRUCTIONS TX81x TX82x 9 001:2008 ISO CERTIFIED COMPANY TABLE OF CONTENTS General Information Generial Information, Features...Page 3 Specifications...Page

More information

Inline Ultrasonic Flowmeter

Inline Ultrasonic Flowmeter M-1500 Series Installation and Operating Manual The M-1500 series is an inline primary flow sensor and externally mounted controller unit. The flow sensor is a straight through flow tube that uses Transit

More information

Signet Measurement and Instrumentation

Signet Measurement and Instrumentation F Piping Systems Signet Measurement and Instrumentation Price List effective January 1, 2018 NEW! DryLoc ph/orp Smart Sensor Electronics See page 37 for new lower pricing on Portaflow Ultrasonic Flow Meters!

More information

Instrument Enclosure Assemblies

Instrument Enclosure Assemblies Instrument Enclosure Assemblies Standard instrument enclosure Instrument enclosures offer a simple solution for the customer who doesn t have the time to install Signet meters into panels. Whether it s

More information

Paddle-wheel flow controller with optical principle for On/Off control

Paddle-wheel flow controller with optical principle for On/Off control Paddle-wheel flow controller with optical principle for On/Off control Type 8039 can be combined with... Indication, monitoring, transmitting and On/Off control in one device. Programmable s (transistor

More information

Positive displacement flowmeter for continuous flow measurement

Positive displacement flowmeter for continuous flow measurement 8070 Positive displacement flowmeter for continuous flow measurement High accuracy Medium with high viscosity Mounting and dismounting of the electronics by a quarter-turn Connection to Bürkert devices

More information