Aqua Metrix. Water Analytics AquaMetrix Price List. AquaMetrix products are manufactured by. Water Analytics
|
|
- Susanna Cameron
- 5 years ago
- Views:
Transcription
1 2018 AquaMetrix Price List (Rev 2.0/ effective August 2018) AquaMetrix products are manufactured 100 School Street Andover, MA tel toll free (855-pHProbe) fax
2 New in 2018 Price Book Unless otherwise noted, the standard lead time is two weeks or less Special order product lead times vary, may be over standard lead times Express ship program: most popular products are shipped within 24 hours Look for this logo. Hr 24 Shipping It means we stock the most common configuration of the poduct and we will ship it within 24 hours ARO. Look for the highlighted product options as shown in blue. Electronics Standard 5-wire sensor 60 Two wire transmitter, 4-20 ma output $ Dual output transmitter ph/orp and Temperature (R8 only) $200 T65 A $100 minimum order quantity enables eligibility for partner discount New application and conductivity cell constant charts on page 17 For options marked contact a representative for lead times
3 Contents AM-2250 Single Input, Multi-Parameter Controller 4 AM-2251 Single Input, Multi-Parameter Controller AM-2250TX Single Input, Multi-Parameter Transmitter AM-2300 Multi-Input Universal Controller 5 60 and 65 Series Differential ph or ORP Sensors Series Combination ph or ORP Sensors 7 AS Series CPVC Conductivity Sensors 8 AM Series Stainless Steel Conductivity Sensors 9 ES-5 Series Toroidal Conductivity Sensor 10 AM-ES1 Toroidal Conductivity Sensor AM-ODO Analog Output Optical Dissolved Oxygen Sensor 11 AM-CDO Series Dissolved Oxygen Sensor AM-FCL Direct Output Free Chlorine Sensor 12 AM-LL Contacting Liquid Level Controller 13 AM-TBR Turbidity Sensor Seametrics Flow Sensors 14 Price and Materials Matrix for Seametrics Sensors and Mountings 15 Appendix A Calibration Standards 16 GLI (Hach) Replacement Sensors Sensor Application Chart 17 Controller Compatability Chart Cell Constant Refernce Chart Appendix B AquaMetrix Product Tree 18 3
4 AM-2250 Single Input, Multi-Parameter Controller ph ORP Conductivity Flow Highly visible back-lit LCD display Three control relays for rising or falling processes, in-range alarms Two 4-20 ma outputs with range scaling PID Control Universal mounting hardware provided for surface and panel mounting NEMA 4X / IP68 waterproof enclosure Compatible with AquaMetrix 60-series differential ph/orp sensors, 500-series combination ph/orp sensors, AS-series and AM-series conductivity cells, and most pulse/frequency flow sensors. Two year limited warranty AM-2250 Hr 24 Shipping Analyzers/Transmitters AM-2251 Single Input, Multi-Parameter Controller D.O. Toroidal Conductivity ph ORP Highly visible back-lit LCD display Three control relays for rising or falling processes, in-range alarms Two 4-20 ma outputs with range scaling PID Control Universal mounting hardware provided for surface and panel mountin NEMA 4X / IP68 waterproof enclosure Compatible with AquaMetrix AM-ES1 toroidal sensor, AM-CDO dissolved oxygen sensor, 60-series differential ph/orp sensors, 500-series combination ph/orp sensors Two year limited warranty AM-2250TX Single Input, Multi-Parameter Transmitter ph ORP Conductivity Flow Single 4-20mA output with range scaling PID Control Universal mounting hardware provided for surface and panel mounting Din-mount version available NEMA 4X / IP68 waterproof enclosure Compatible with AquaMetrix 60-series differential ph/orp sensors, 500-series combination ph/orp sensors, AS-series and AM-series conductivity cells, and most pulse/frequency flow sensors. Two year limited warranty AM-2251 Hr 24 Hr 24 Shipping AM-2250TX Shipping Accessories and Mounting Hardware (B) 24VDC-ADP External power supply 24 VDC POWER-CORD Power cord 5 ft 2250-USB-TTL Cable for field firmware upgrade 2250-PIPE-MNT 2250-DIN-MNT Pipe mounting hardware DIN rail mounting hardware 4
5 2300 Multi-Input Universal Controller Inputs for four 4-20 ma sensors of any kind in any combination: ph, ORP, conductivity, dissolved O 2, Chlorine, and more. Inputs for three flow sensors or contact switches Outputs of four relays (5A-240 V) programmable for any of the inputs Alarm notifications , text, and/or display for each input 100% web enabled from set-up to data collection to remote viewing, with password protection, and SSL encryption Perform differential measurement from two analog inputs Data logging downloadable from web interface, FTP, or 1/4 DIN panel mounted enclosure with adapter for wall mounting Three levels of security to control appropriate access for personnel ModBus via TCP/IP One year limited warranty 24 AM Hr Shipping Inputs Outputs ADD 4X Analog 3X Digital 4X Relays 0 8X Analog 3X Digital 4X Relays 1 4X Analog 3X Digital 4X Relays 4X Analog (4-20mA out) 2 4X Analog 6XDigital 8X Relays 3 4X Analog 3X Digital 10x Relays 4 8X Analog 6X Relays 5 4X Analog 7X Digital 6X Relays 6 8X Analog 12X Relays 8 Accessories and Mounting Hardware (B) 2300-WALL-ENCL NEMA 4X Enclosure for wall mounting, including mounting hardware and pre-drilled conduit holes 2300 CARD4-20 IN Expansion card with additional 4-20 IN 2300 CARD4-20 OUT Expansion card with additional 4-20 out 2300 CARD RELAY Expansion card with additional relays 2300 CARD PULSE Expansion card with additional pulse inputs 2300 CARD 7DIG Expansion card with additional digital inputs 2300 CARD 12REL Expansion card with additional relays 2300 Demo Kit For Distributors Only Consists of 2300, ES-5 conductivity sensor, P65R8 ph sensor, Tenda wireless router. Packed in a compact, durable carrying case. AquaMetrix provides custom configuration of any 2300 with sensors at a nominal charge.configured 2300 s arrive at the customer site ready to work out of the box. Call for pricing options. 5
6 60 and 65 Series Differential ph or ORP Sensors ph / ORP Accurate differential measurement Replaceable salt bridge Flow through or fully submersible installation Temperature compensation device in all sensors Compatabile with HACH/GLI sensors (see page 16) Two year limited warranty Application ph ORP Electronics Standard 5-wire sensor 60 Two wire transmitter, 4-20 ma output 65 Dual output transmitter ph/orp and Temperature (R8 only) Body Type Fixed insertion, 1.5 NPT threaded ends, Ryton Fixed insertion, 1.0 NPT threaded ends, Ryton R5-series sensor replaces 1 NPT CPVC C5-series Hot Tap insertion for AM-HTC-7, CPVC Enhanced Performance Options (only if required) Standard electrode Hardened glass electrode for ph sensors (R8, C7 only) Flat faced glass electrode for ph sensors (R8, C7 only) Antimony electrode for ph sensors (R8 only) For up to 5% HF-acid applications. Because of the corrosive nature of HF this probe is not covered the Aquametrix 2 year warranty. Gold electrodes for ORP sensors (R8, C7 only) Custom Cable Length P R T65 Standard 15 ft (4.5m) cable - Ships in 24 hours 015 Custom cable $2/ft applies for the entire cable length. Maximum cable length is 2000 ft Hr 24 R8 R5 C7 H F A G XXX Shipping P 60 R8-015 Accessories and Mounting Hardware (B) AM-SBK-8 AM-SBK-567 AM-SBK-R5 AM-SFL-8 / AM-SFL-5 AM-HTC-7 AM-ARM-8 / AM-ARM-5 AM-JET-8 / AM-JET-5 AM-PTR-8 / AM-PTR-5 AM-TEE-8 / AM-TEE-5 AM-CFT-R5 AM-JB1 AM-CBL60/ AM-CBL65 Salt bridge kit (3 pack) for -R8 series sensors Salt bridge kit (3 pack) for -C6/7 series sensors Salt bridge kit (3 pack) for R5-series sensors 2 Sanitary flange for -8 and -5 series sensors CPVC hot tap ball valve assembly for C7-series sensors Submersion hardware for tank mounting for -8 and -5 series sensors Jet Cleaner for -8 and -5 series sensors Electrode protector for -8 and -5 series sensors 2 Union Tee with adapter for -8 and -5 series sensors Compression fitting for R5 sensor Junction box with integrated terminal strip Extension cable for 60-series or 65-series sensors 6
7 500 Series - Combination ph or ORP Sensors Double Junction (Ceramic/Pellon) electrodes Temperature compensation device Flow through or submersible installation Rugged CPVC outer shell One year limited warranty Hr 24 Shipping P 575 T1-015 Application ph ORP Body Type 1 MNPT threaded ends, fixed insertion 575 3/4 MNPT CPVC compression fitting, variable insertion 585 Temperature Compensation and Electrode Options PT1000RTD - standard for all 500-series sensors Other temperature devices are available as a special order: 300NTC (T2), 3000NTC (T3), PT100RTD (T4) HF resistant ph electrode (up to 2%) glass with ATC 1 PT1000RTD(HF1), 300NTC(HF2), 3K NTC(HF3), PT100RTD(HF4) Antimony electrode (up to 5% HF resistant) (ph only) Single Junction, no ATC device 1 Cable Option Standard tin-prepped wires BNC connector for ph or ORP Cable Length P R T1 TX HFX HFA BNC Standard 15 ft (4.5m) cable - Ships in 24 hours 015 Custom cable $2/ft applies for the entire cable length. Maximum cable length is 50 ft XXX ph / ORP 1 Because of the extreme corrosive nature of HF this sensor is not covered the one year warranty for combination probes. Accessories and Mounting Hardware (B) AM-500-BNC AM-BT1 AM-SFL-5 AM-ARM-5 AM-JET-5 AM-PTR-5 AM-TEE-5 AM-JB1 AM-TEE-AS AM-CCF-AS AM-SCF-AS Tinned wire to BNC adapter 4-20 ma blind transmitter for ph or ORP sensors with ATC PT1000RTD 2 Sanitary flange for 575 sensors Submersion hardware for tank mounting for 575 sensors Jet Cleaner for 575 sensors Electrode protector for 575 sensors 2 Union Tee with adapter for 575 sensors Junction box with integrated terminal strip 1 Union Tee with 3/4 fitting for 585 sensors CPVC 3/4 compression fitting for 585 sensors 316SS 3/4 compression fitting for 585 sensors 7
8 AS Series - CPVC Conductivity Sensors Aqua High temp epoxy encapsulated CPVC shell 24 Metrix Hr Shipping SS electrode for general application and Graphite for corrosive 3/4 NPT variable insertion Flow through or submersible installation Temperature compensation device Multiple cell constants are available (See page 17 for conductivity ranges) Two year limited warranty AS M 1 P Electrode 316 Stainless Steel M Impregnated Graphite Cell Constant G Cell constant 0.01 (0.2-10uS/cm) 001 Conductivity Cell constant 0.1 (10-500uS/cm) 01 Cell constant 1.0 (100-5,000uS/cm) 1 Cell constant 10 (Graphite only) (1-50mS/cm) 10 Cell constant 50 (Graphite only) (5-250mS/cm) 50 Sensor Mounting Options 3/4 MNPT CPVC compression fitting P 3/4 MNPT SS compression fitting S Extended length sensor for use with hot tap ball valve AM-HTC-AS Temperature Compensation PT1000RTD Standard electrode 1 Other temperature devices are available as a special order: 300NTC (2), 3000NTC (3), PT100RTD (4) Cable Length Standard 15 ft (4.5m) cable - Ships in 24 hours 015 Custom cable $2/ft applies for the entire cable length. Maximum cable length is 50 ft HT X XXX Accessories and Mounting Hardware (B) AM-HTC-AS AM-ARM-AS AM-SFL-AS AM-CBLAS AM-JB1 AM-TEE-AS AM-CCF-AS AM-SCF-AS CPVC hot tap ball valve assembly, 3/4 FNPT Submersion hardware for tank mounting for AS series sensors 2 Flange for AS sensors Extension cable for AS sensors Junction box with integrated terminal strip 1 Union Tee with 3/4 adapter for AS sensors CPVC 3/4 compression fitting for AS sensors 316SS 3/4 compression fitting for AS sensors 8
9 AM Series - Stainless Steel Conductivity Sensor 316 SS sensor for high temp and pressure applications Variable insertion 1/2 or 3/4 NPT process connection Flow through or submersible installation Temperature compensation device Multiple cell constants are available (See page 17 for conductivity ranges) One year limited warranty AM12 1 K Sensor type Stainless steel 1/2 sensor Stainless steel 3/4 sensor Stainless steel 3/4 sensor with Stainless Steel fitting for boiler applications Cell Constant AM12 AM34 AMB34 Cell constant 0.01 (0.2-10uS/cm) 001 Cell constant 0.1 (10-500uS/cm) 01 Cell constant 1 (100-5,000uS/cm) 1 Cell constant 10 (only AM12, AM34) (1-50mS/cm) 10 Cell constant 50 (only AM34) (5-250mS/cm) 50 Sensor Mounting Options KYNAR compression fitting 316SS compression fitting Extended length sensor for use with hot tap ball valve Temperature Compensation Device PT1000RTD Temperature Device 1 Other Temperature Devices are available as a special order: 300NTC (2), 3000NTC (3), PT100RTD (4) Cable Length Standard 15 ft (4.5m) cable 015 Custom cable $2/ft applies for the entire cable length. Max cable length should not exceed 50 ft K S HT X XXX Conductivity Accessories Mounting Hardware (B) AM-HTC-AM12 AM-HTC-AM34 AM-ARM-AS AM-SFL-AS AM-CBL-AS AM-JB1 AM-TEE-AS AM-KCF-AM12 /AM34 AM-SCF-AM12 /AM34 316SS hot tap ball valve assembly for AM12-HT sensors 316SS hot tap ball valve assembly for AM34-HT sensors Submersion hardware for tank mounting for AM34 series sensors 2 Sanitary flange for AM34 sensors Extension cable for AM sensors Junction box with integrated terminal strip 1 Union Tee with 3/4 adapter for AM34 series sensors Kynar compression fitting for AM12 amd AM34 series sensors 316SS compression fitting for AM12 and AM34 series sensors 9
10 ES-5 Series Toroidal Conductivity Sensors ES ma isolated output Note: The ES-5 is compatible with CPVC outer shell the AM-2300 Controller 1-1/2 MNPT threaded ends Temperature compensation device Multiple cell constants are available (See page 17 for conductivity ranges) One year limited warranty ES-5- C Conductivity Effective Cell Constant Range ADD 0.2 to 10 ms/cm C1 2 to 100 ms/cm C2 20 to 1000 ms/cm C3 Cable Length Standard 15 ft (4.5m) cable 015 Custom cable $4/ft applies for the entire cable length. Maximum cable length is 2000 ft AM-ES1 Toroidal Conductivity Sensors XXX AM-ES1 Polypropylene body Note: The AM-ES1 is compatible with 3/4 NPT thread the AM-2251 Controller Temperature compensation device Replaces GLI 3725E2T sensor Wide measuring range. See chart on pg.17 for full range One year limited warranty AM-ES1-015 Cable Length ADD Standard 15 ft (4.5m) cable 015 Custom cable $2/ft applies for the entire cable length. Maximum cable length is 50 ft XXX Accessories Mounting Hardware (B) AM-CBL-60 AM-JB1 AM-TEE-ES Extension cable for AM-ES1 sensors Junction box with integrated terminal strip 2 Union Tee with adapter 10
11 AM-ODO Direct Output Optical Dissolved Oxygen Sensor PVC construction Dual output (%sat and mg/l) or temp and mg/l Direct output via 4-20 ma or 0-5V Salt water compensation with toggle Only 1 replaceable part (sensor cap) Not affected CO 2 or H 2 S One year limited warranty AM-ODO Options Temperature and mg/l Option ADD T Cable Length ADD Standard 15 ft (4.5m) cable 015 Custom cable $4/ft applies for the entire cable length. Maximum cable length is 1000ft Accessories (B) AM-ODO-CAP AM-ODO-MPR AM-ODO-UIB AM-ODO-T-UIB Replacement membrane cap Metal protector AM-CDO Amperometric Dissolved Oxygen Sensor Polarographic (Clark) Measuring Technique Wide dynamic range: 0-250% saturation Transmission up to 2000 ft (600 m) 15 ft (4.5 m) cable Compatible with AM-2251 and 2200D controller Replaces AM-P91 sensor One year limited warranty Converter Box for % sat and mg/l Converter Box for temperature and mg/l Note: The AM-CDO is compatible with the AM-2251 Controller XXX AM-CDO Dissolved Oxygen (D.O.) Cable Length ADD Standard 15 ft (4.5m) cable 015 Custom cable $2/ft applies for the entire cable length. Max cable length is 2000 ft XXX Accessories Mounting Hardware (B) New AM-ARM-5 AM-JB1 AM-CBL60 AM-TEE-5 AM-CDO-KIT AM-CDO-CAP Submersion hardware for tank mounting for C91 sensors Junction box with integrated terminal strip Extension cable for C91 sensors 2 Union Tee with adapter Refill solution 30mL, membrane, and polishing strips Replacement Membrane Cap 11
12 AM-FCL Direct Output Free Chlorine Sensor 2-Electrode amperometric design Loop powered direct 4-20mA output Automatic temperature compensation Inexpensive replaceable membrane and electrolyte One year limited warranty AM-FCL Free Chlorine Concentration Range 0-2 ppm ppm ppm 10 Cable Length ADD Standard 15ft (4.5m) cable 015 Custom cable $4/ft applies for the entire cable length. Maximum cable XXX length is 1000ft Due to extreme flow dependancy flow cell and flow meter are highly recommended Chlorine Accessories (B) AM-FCL-FC AM-FCL-FM AM-FCL-RE AM-FCL-MC Flow Cell Flow Meter Electrolyte Membrane Cap 12
13 AM-LL Contacting Liquid Level Controllers AC based conductivity SPDT (single pole double throw) relay Built in sensitivity adjustment (timer for LL3) Current and voltage limited NEMA1 enclosure Two year limited warranty AM- LL Configuration Options ADD 10 kω max sensitivity, double pole, double throw, relay timer adjustment 3 10 kω sensitivity, single pole, double throw 4 10 kω sensitivity, single pole, double throw plus auxiliary normally open contacts 1MΩ sensitivity, single pole, double throw plus auxiliary normally open contacts Power Options 120VAC VAC H AM-TBR Turbidity Sensor Nephilometric measurement Loop powered direct 4-20mA output (IR VERSION) Optional constant pressure flow cell Automatic temperature compensation One year limited warranty AM-TBR-IR 40 Level Light Source White Light (USEPA180.1) Infrared (ISO 7027) WL IR Turbidity Range 0-4 NTU NTU NTU 400 Accessories (B) AM-TBR-FC40 AM-TBR-FC400 AM-TBR-TEE Flow Cell for 0-4 and 0-40 range sensors Flow Cell for range sensors 2 Union Tee for Turbidity Sensor 13
14 Flow Seametrics Flow Sensors Pulsed output works with AM-2250 controller For pipe diameters of 3/8 to 48 IP sensor with Kynar impeller, ru jewel bearing and tungsten carbide shaft EX sensor with no moving parts and superior low-flow perfomance SPX sensor with FNPT threads for very low minimum flow rates 18 (5.5m) standard cable One year limited warranty Sensor Type and Style Impeller sensor ( 1/2-3 ) fixed insertion Impeller sensor ( 4-8 ) fixed insertion Impeller sensor ( 3-12 ) variable insertion Impeller sensor ( ) variable insertion Impeller sensor (3-12 ) hot-tap insertion Impeller sensor (12-40 ) hot-tap insertion Magmeter sensor ( 1-3 ) fixed insertion Magmeter sensor ( 4-10 ) fixed insertion Magmeter sensor ( 12 ) fixed insertion Magmeter sensor (3-10 ) variable insertion Magmeter sensor (10-48 ) variable insertion Magmeter sensor (3-10 ) hot-tap insertion Magmeter sensor (10-48 ) hot-tap insertion Sensor Material PVC Stainless Steel Brass Mounting Type (only if required) none Tee Saddle Weldolet Mounting Material PVC Carbon Steel (Iron for Saddle) Stainless Steel Brass/Bronze Pipe Dimension Code See page 17 for three/four digit code Sensor Type and Style IP810 IP820 IP110 IP210 IP150 IP250 EX810 EX820 EX830 EX110 EX210 EX150 EX250 P S B T S W P C S B -XXX In-line type with 3/8 FNPT 038 In-line type with 1/2 FNPT 050 In-line type with 3/4 FNPT 075 In-line type with 1 FNPT 100 Price Category (C) IP810 P T P Base Price (C) $525 SPX
15 Price and Materials Matrix for Seametrics Sensors and Mountings The many possible combinations of fitting type, size and material make the pricing of the sensors and fittings more involved than the simple menu options listed for other sensors. The chart below makes the fitting selection process simple. Replacement parts and accessories are available upon request. Please contact your representative for details. Sensor price category (C) Impeller type IP810 PVC (P) Stainless Steel (S) Brass (B) Magmeter type EX810 PVC (P) Stainless Steel (S) Brass (B) IP820 EX820 IP110 EX830 IP210 EX110 IP150 EX210 IP250 EX150 EX250 Mounting price category (C) Fixed Insertion IP810 IP820 n/a n/a EX810 EX820 EX830 Pipe Diameter 1/2 3/ / Dimension Code PVC (P) Flow Tee Bronze (B) Carbon Steel (C) SS (S) Saddle Weldolet PVC (P) Ductile Iron (S) Bronze (B) Brass (B) Carbon Steel (C) SS (S) Variable Insertion and Hot-Tap IP110/IP150 EX110/EX150 IP210/IP250 EX210/EX250 Pipe Diameter Dimension Code Saddle Iron (C) 15
16 Appendix A ph Calibration Standards (A) AM-PH4-1P AM-PH4-1G AM-PH7-1P AM-PH7-1G AM-PH10-1P AM-PH10-1G ph 4 buffer solution, 500mL (1 pint) ph 4 buffer solution, 4L (1 gallon) ph 7 buffer solution, 500mL (1 pint) ph 7 buffer solution, 4L (1 gallon) ph 10 buffer solution, 500mL (1 pint) ph 10 buffer solution, 4L (1 gallon) Calibration ORP Calibration Standards (A) AM-R200-1P AM-R200-1G AM-R600-1P AM-R600-1G 200 mv ORP buffer solution, 500 ml (1 pint) 200 mv ORP buffer solution, 4L (1 gallon) 600 mv ORP buffer solution, 500 ml (1 pint) 600 mv ORP buffer solution, 4 L (1 gallon) Conductivity Calibration Standards (A) AM-C050U-1P AM-C100U-1P AM-C500U-1P AM-C001M-1P AM-C005M-1P AM-C010M-1P AM-CXXXX-1P AM-CXXXX-1G 50 µs (.05 ms) calibration solution, 500 ml (1 pint) 100 µs (.1 ms) calibration solution, 500mL (1 pint) 500 µs (0.5mS) calibration solution, 500mL (1 pint) 1000 µs (1mS) calibration solution, 500mL (1 pint) 5000 µs (5mS) calibration solution, 500mL (1 pint) 10,000 µs (10mS) calibration solution, 500mL (1 pint) Custom conductivity calibration solution, 500mL (1 pint) Custom conductivity calibration solution, 4L (1 gallon) Controllers that are compatible with AquaMetrix sensors P60 series sensors will work with AquaMetrix 2250/2250TX, Shark-120/TX, Hach SC100, Hach SC200, GLI53 and many others P65 and PT65 series sensors will work with AquaMetrix 2300, Hach SC200 and any PLC with analog inputs GLI (Hach) Replacement Sensors GLI Part Number Aquametrix Part Number GLI Part Number Aquametrix Part Number 6022P0 P60R8-015 DPD1P1 P60R P0 P60R8-015 DPD2P1 P60R P0 P65R8-015 DRD1P5 R60R P0 P65R8-015 DRD1R6 R60R P0 P60R8-015 PD1P1 P65R P0 P60R8-015 PD1R1 P65R P0 P65R8-015 RD1R5 R65R
17 Appendix A (Continued) Sensor Applications Application ph ORP Conductivity D.O. Level Flow Chlorine Wastewater Filtration HVAC Pump/Lift Station Tank Monitoring Aquaculture Food & Beverage Controller Compatability Chart Sensor AM-2250 AM-2250TX AM-2251 AM Series Sensors 65 Series Sensors 500 Series Sensors AS Series Sensors AM Series Sensors ES-5 Toroidal Sensors AM-ES1 Toroidal Sensor AM-ODO Sensors AM-CDO Sensors AM-FCL Chlorine Sensor AM-TBR Turbidity Sensor Seametrics Flow Sensors Conductivity Cell Constant Chart Conductivity measurement range 5-500,000 µs/cm Wide Range Toroidal (AM-ES1) Toroidal (ES5C1) Toroidal (ES5C2) Toroidal (ES5C3) Cell Constant=0.01 (ASM001) Cell Constant=50 (ASG50) Cell Constant =10 (ASG10) Cell Constant=1 (ASM1) Cell Constant=0.1 (ASM01) ,000 10, ,000 1,000,000 µs/cm (Log scale) 17
18 Appendix B Probes / Sensors Controllers / Transmitters Temperature Flow Dissolved Oxygen Chlorine Turbidity Level AM-2300 Cloud Based UI (LAN or Cellular) UniFi Multi Input Controller AM-2300 Contacting Controller AM-LL Series NTU 4-20 ma AM-TBR Free Chlorine 4-20 ma AM-FCL Luminescent 4-20 ma AM-ODO Polarographic (Clark) AM-CDO Variable Insertion 110/210 Series Fixed Insertion 800 Series Stainless Steel 4-20 ma AM-T 2250-Series ph / ORP Conductivity Contacting Inductive Combination Differential Single Input Controllers Single Input Transmitter ph/orp/flow/ Conductivity AM-2250TX ph/orp/do/ Conductivity AM-2251 ph/orp/flow/ Conductivity AM-2250 Hot Tap Insertion C7 Series Fixed Insertion R5 Series Fixed Insertion R8 Series Variable Insertion 585 Series Fixed Insertion 575 Series CPVC 4-20mA AM-ES5 Wide Range AM-ES1 Stainless Steel AM Series CPVC AS Series Solutions for the Most Challenging Environments 18
19
20 100 School Street Andover, MA fax
Encapsulated Differential ph and ORP Sensors (available in LCP, foreground, or Ryton body materials)
Technology For Solutions Data Sheet LRE/102 Supersedes LRE/400 Encapsulated Differential ph and ORP Sensors (available in LCP, foreground, or Ryton body materials) Common Features Differential Electrode
More informationModel Q45H/ Residual Chlorine Monitor...
Model Q45H/62-63 Residual Chlorine Monitor... ATI s Model Q45H is designed for on-line monitoring and control of chlorination systems. It is available in two versions: a free chlorine monitor for drinking
More informationSignet 3719 ph/orp Wet-Tap Assembly
Signet 3719 ph/p Wet-Tap Assembly Features Electrode removal without process shutdown Space saving 45 mm (1.75 in.) short-stroke design Sealed pneumatic dampening for smooth and safe operation SafeLoc
More informationOPERATING INSTRUCTION MANUAL
OPERATING INSTRUCTION MANUAL MODEL P/R65 DIFFERENTIAL 2-WIRE (4-20 ma) ph & ORP PROBES N116-139 REV. 0 Aquametrix, by Water Analytics Inc. 100 School Street Andover, MA 01810 Tel: (978) 749-9949 Toll Free:
More informationSignet ph/orp Electrodes
Signet 2724-2726 ph/orp Electrodes Compatible with ALL Signet ph/orp Instruments Features Patented reference design for exceptional performance * Mounts in Signet standard fittings from DN15 to DN100 (½
More informationSignet DryLoc ph/orp Electrodes
Signet 2774-2777 DryLoc ph/orp Electrodes Features Patented DryLoc connector with gold plated contacts* Special design allows for installation at any angle, even inverted or horizontal Quick temperature
More informationSeaMetrics Flow Meters and Flow Computers
Distributed Products Fact Sheet and Flow Computers WTP-PVC body turbine flow meter WT-S Stainless steel body turbine flow meter TX115/215 Hottap insertion turbine flow meter FT420 Looppowered flow computer
More informationSignet ph/orp Electrodes
Signet 2724-2726 ph/orp Electrodes Compatible with ALL Signet ph/orp Instruments Features Flat Glass Protected Bulb Patented reference design for exceptional performance * Mounts in Signet standard fittings
More information* * Rev. 9 01/18 Product Manual
English Signet 2760 DryLoc ph/orp Preamplifier *3-2760.090* 3-2760.090 Rev. 9 01/18 Product Manual Description The Signet 2760 ph/orp Preamplifiers with DryLoc connectors are part of Signet's growing line
More informationGeneral Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.J January 2011
Product Data Sheet PDS 71-400/rev.J January 2011 Model 400 and 400VP Series ENDURANCE General Purpose Conductivity Sensors INITIAL CALIBRATION NOT REQUIRED. Pre-determined cell constant ensures out-of-the
More informationSignet Conductivity/Resistivity Electrodes
Signet 2818-2823 Conductivity/Resistivity Electrodes 2818 2819 2820 2821 2822 2823 Sanitary Features Standard process connections - Polypro - SS on 10 and 20 cell - Tri-clamp 1-1½ in., 2 - Opt. ½ in. NPT
More informationSignet DryLoc ph/orp Electrodes
Signet 2774-2777 DryLoc ph/orp Electrodes Features Patented DryLoc connector with gold plated contacts* Special design allows for installation at any angle, even inverted or horizontal Quick temperature
More informationOPERATING INSTRUCTION MANUAL MS SERIES CONDUCTIVITY CELLS
OPERATING INSTRUCTION MANUAL MS SERIES CONDUCTIVITY CELLS REV. 3.1 Water Analytics, Inc. 100 School Street Andover, MA 01810 978-749-9949 Toll free: 855-747-7623 Fax: 978-749-9961 www.wateranalytics.net
More informationSignet Measurement and Instrumentation
F Piping Systems Signet Measurement and Instrumentation Price List effective January 1, 2015 Conveyance Pipe, Fittings, Joining Technology // PVC/CPVC // PPro-Seal PP // PROEF PP // SYEF PVDF // Contain-It
More informationGeneral Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.I December 2008
Product Data Sheet PDS 71-400/rev.I December 2008 Model 400 and 400VP Series ENDURANCE General Purpose Conductivity Sensors INITIAL CALIBRATION NOT REQUIRED. Pre-determined cell constant ensures out-of-the
More informationSignet Conductivity/Resistivity Electrodes
Signet 2818-2823 Conductivity/Resistivity Electrodes 2818 2819 2820 2821 2822 2823 Sanitary Features Standard process connections - Polypro - SS on 10 and 20 cell - Tri-clamp 1-1½ in., 2 in. - Opt. ½ in.
More informationNEW QUICK CABLE-TO-SENSOR RELEASE,
Models 399 and 399VP Product Data Sheet PDS 71-399 October 2000 ph/orp Sensors NEW OPTIONS to meet a variety of application requirements, including: * Low ionic strength water * Processes with hydrofluoric
More informationAccessories Guide ph/orp/conductivity Sensors
Jet Cleaners and Scrubber Accessories Isolation Ball Valves Assemblies Compression Fittings and Sheath Sets High Pressure (2500 PSIG) Sensor Housings In-line Flow Cells Nut Lock Union Style Adapters Sensor
More informationGeneral Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.K February 2013
Product Data Sheet PDS 71-400/rev.K February 2013 Model 400 and 400VP Series ENDURANCE General Purpose Conductivity Sensors INITIAL CALIBRATION NOT REQUIRED. Factory-measured cell constant ensures out-of-the-box
More informationSignet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems with PVDF Sensor
Signet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems with PVDF Sensor Features Test certificate supplied with all sensors Universal Mount Custom cell constant programmed into the
More informationLow Cost Submersion and In-Line ph Electrodes
Low Cost Submersion and In-Line Electrodes Economical design for in-line or submersion use Choose from single or double models Threaded 1/2" or 3/4" NPT connections Choose from spherical or flat measuring
More informationAn IDEX Water & Wastewater Business. pulsafeeder.com. Boiler. Programmable Boiler Controller
An IDEX Water & Wastewater Business pulsafeeder.com Boiler Programmable Boiler Controller Pulsafeeder Expertise Technology is the key to delivering responsible products to the markets that we serve. Leading
More informationSignet 2760 DryLoc ph/orp Preamplifier
Signet 2760 DryLoc ph/orp Preamplifier *3-2760.090* 3-2760.090 Rev. H 05/11 English English SAFETY INSTRUCTIONS 1. Depressurize and vent system prior to installation or removal. 2. Confi rm chemical compatibility
More informationecotrans Lf 01/02 Microprocessor Transmitter / Switching Device for Conductivity
Data Sheet 20.27 Page / ecotrans Lf 0/02 Microprocessor Transmitter / Switching Device for Conductivity Type 2027 Housing for DIN rail mounting (5 x 7.5 mm to EN 0 75 A.) Brief description The JUMO ecotrans
More informationGeneral Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.G February 2006
Product Data Sheet PDS 71-400/rev.G February 2006 Model 400 and 400VP Series ENDURANCE General Purpose Conductivity Sensors INITIAL CALIBRATION NOT REQUIRED. Pre-determined cell constant ensures out-of-the
More informationSignet Measurement and Instrumentation
F Piping Systems Signet Measurement and Instrumentation Price List effective January 1, 2018 NEW! DryLoc ph/orp Smart Sensor Electronics See page 37 for new lower pricing on Portaflow Ultrasonic Flow Meters!
More informationph/orp Sensor Model 399 ph/orp
Model 399 ph/orp Product Data Sheet PDS 71-399 September 1999 ph/orp Sensor DOUBLE JUNCTION REFERENCE CELL provides longer sensor life in process solutions containing poisoning ions. ONE-PIECE CONSTRUCTION
More informationSignet 2760 DryLoc ph/orp Preamplifiers & Connectors
Signet 2760 DryLoc ph/orp Preamplifiers & Connectors Features In-line integral mount and submersible installation versions Automatic temperature compensation Auto configuration for ph or ORP operation
More informationSignet ph/orp Electrodes
Signet 2734-2736 ph/orp Electrodes Compatible with Signet 8900/9900 Instruments Features Patented reference design for exceptional performance * Mounts in Signet standard fittings from DN15 to DN100 (½
More informationSignet 3719 ph/orp Wet-Tap
Signet 3719 ph/orp Wet-Tap *3-3719.090* 3-3719.090 Rev H 09/07 English Do not exceed maximum temperature/pressure specifications. Wear safety goggles or face shield during installation/service. Do not
More informationSIGNET 2760 DryLoc ph/orp Preamplifier
SIGNET 2760 DryLoc ph/orp Preamplifier 3-2760.090 3-2760.090 (A-3/04) English SAFETY INSTRUCTIONS 1. Depressurize and vent system prior to installation or removal. 2. Confirm chemical compatibility before
More informationSOLENOID DRIVEN DOSING PUMPS
MAIN COMMON FEATURES SOLENOID DRIVEN DOSING PUMPS LIQUID ENDS Power supply: 230 Vac (±10 / 15%) / 1 phase / 50/60 Hz WETTED PARTS STANDARD conf. Available conf. Reproducibility under standard conditions:
More informationDissolved Oxygen Measurement System with Air Blast Cleaner
Product Data Sheet PDS 71-DO-03/04/rev.D August 2004 MODEL DO -03/-04 Dissolved Oxygen Measurement System with Air Blast Cleaner COMPLETE SYSTEM INCLUDES sensor, analyzer, sensor washer head, mounting
More informationDigital ph transmitter
Digital ph transmitter Compact, remote versions for DN 15 to 200 Fully programmable ph transmitter functions for all kinds of ph-measurement tasks Large range of process connections with various fittings
More informationGeneral Purpose Toroidal Conductivity Sensors
Product Data Sheet PDS 71-226/228/revF January 2011 Model 226 and 228 General Purpose Toroidal Conductivity Sensors NON-CONTACTING (TOROIDAL) SENSORS resist corrosion and fouling. SENSORS ARE IDEAL for
More informationProSeries NEMA 4X SONIC-PRO. Engineering and Technical Data. Transit Time Ultrasonic Flowmeter. Industries, Ltd. s Ultrasonic Flow Meters
ProSeries by Blue-White Industries, Ind. Ltd. Industries, Ltd. s SNIC-PR s SNIC-PR s S4 Transit Time Ultrasonic Flowmeter ½ thru 2 diameter Pipe Sizes Inline spool piece Advanced communications Data logging
More informationGeneral Purpose ph/orp Sensors
Product Data Sheet PDS 71-3900/rev. B December 2010 Models 3900 and 3900VP General Purpose ph/orp Sensors EXTENDED SENSOR LIFE provided by double junction reference. ENHANCED PERFORMANCE AND INCREASED
More informationAGUABEL. Index. Aguapure Aguapure Lara APS 3. P-Pump 4. Aspendose 5. Tank for chemical 6. Tank with mixer 6. Glass Sensor 7.
Page 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Index Aguapure 100 2 Aguapure 200 2 Lara APS 3 P-Pump 4 Aspendose 5 Tank for chemical 6 Tank with mixer 6 Glass Sensor 7 AguaCon 8 Poolsaver Tetra 10 System
More informationPISTON STYLE GAUGE. For Installation and Operation Manuals Please Visit: Mid-West Instrument
PISTON STYLE GAUGE For Installation and Operation Manuals Please Visit: www.midwestinstrument.com/literature Mid-West Instrument BULLETIN NO. 120/11 (SUPERSEDES BULLETIN NO. 120/02) Mid-West Instrument
More informationGeneral Purpose ph/orp Sensors
General Purpose ph/orp Sensors Product Data Sheet LIQ_PDS_3900 September 2013 General Purpose ph/orp Sensors SMART preamplifier-stores calibration and other data. Extended sensor life provided by double
More informationG2 Industrial Grade Meters
G2 Industrial Grade Meters The unique modular approach of the Industrial Grade Meter line allows you to section 2: g2 industrial grade meters design a meter to match your specific application. Turbine
More informationMid-West Instrument. Piston Type Model 220. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter
BULLETIN NO. 220/11 (SUPERSEDES BULLETIN NO. 220/06) Mid-West Instrument Piston Type Model 220 Hazardous Locations Indicating / Non-Indicating Differential Pressure Switch or Transmitter Low cost piston
More informationConductivity. Inductive Conductivity Sensors. Features and Benefits DATA SHEET. Wide Measuring Range. Low-maintenance Design. Complete Digital System
DATA SHEET Inductive Conductivity Sensors Features and Benefits Wide Measuring Range Hach s Inductive Conductivity Sensors measure 200 up to 2,000,000 microsiemens/cm. A built-in Pt 1000 RTD compensates
More informationModels 396/396P/396R. Retraction/Submersion/Insertion ph/orp Sensor
Models 396/396P/396R Product Data Sheet PDS 71-TUpH September 1999 Retraction/Submersion/Insertion ph/orp Sensor MINIMUM SENSOR MAINTENANCE due to patented TUpH reference technology 1 which ensures steady
More informationAnalytical Instruments Two-Electrode Conductivity Sensors
Data Sheet Analytical Instruments Two-Electrode Conductivity Sensors Model TB2 Superior accuracy in low conductivity measurement ranges. Measurement ranges from 0 to 199.9 µs/cm to 0 to 19.99 ms/cm. Resolution
More informationJUMO ecotrans Lf 01/02
Data Sheet 07 Page /7 JUMO ecotrans Lf 0/0 Microprocessor Transmitter/Switching Device for Conductivity Housing for DIN rail mounting (5 mm 7.5 mm to EN 075 A.) Brief description The JUMO ecotrans Lf 0/0
More informationDigital ph transmitter
Digital ph transmitter Compact, remote versions for DN 15 to 200 Fully programmable ph transmitter functions for all kinds of ph-measurement tasks Large range of process connections with various fittings
More informationSIGNET 2750 ph/orp Sensor ENGLISH
ENGLISH 3-2750.090 B-8/01 English SAFETY INSTRUCTIONS FOR IN-LINE ELECTRODE INSTALLATION 1. Do not remove from pressurized lines. 2. Do not exceed maximum temperature/pressure specifications. 3. Wear safety
More informationortable ph, Conductivity & DO2 Meters
ortable ph, Conductivity & DO2 Meters Enterprise Range Large, back lit LCD Ergonomic design These ergonomically designed products feature a backlit liquid crystal display, a reading hold function and 500
More informationInsertion/Submersion Flow Through Sensor
Product Data Sheet PDS 71-381/rev.B September 2004 Model 381 ph/orp Insertion/Submersion Flow Through Sensor ADVANCED ON-LINE SENSOR DIAGNOSTICS 1 (Model 381+ only), for use with the Models 54e ph/orp
More informationMEASUREMENT AND INSTRUMENTATION FLS
MEASUREMENT AND INSTRUMENTATION FLS The FLS Measurement and Instrumentation line consists of a comprehensive range of Flow, ph, ORP, Conductivity Sensors, Monitors and Transmitters. INDEX SYSTEM SELECTION
More informationSignet 2551 Magmeter Flow Sensor
Signet 2551 Magmeter Flow Sensor Available in a variety of wetted materials and ideal for pipe sizes up to DN900 (36 in.) Features Test certificate included for -X0, -X1 Patented Magmeter technology No
More informationControl and automatic dosing
Control and automatic dosing For public and residential pools Control Basic Plus Control Basic Next Optima and Optima Next dosing pumps Panels for the galvanic and amperometric control Dosing through automatic
More informationElectromagnetic Flowmeters. Product Overview.
Electromagnetic Flowmeters Product Overview www.lcmeter.com Premier products, premier performance Liquid Controls offers a broad selection of electromagnetic (Mag) flow meters for industrial and water
More informationDissolved Oxygen, ph, and Conductivity
Product Data Sheet PDS 71-steam/rev.E February 2005 Steam Sterilizable Solutions Dissolved Oxygen, ph, and Conductivity STEAM STERILIZABLE AND AUTOCLAVABLE DISSOLVED OXY- GEN, ph, AND CONDUCTIVITY SENSORS:
More informationMid-West Instrument. Diaphragm Type Model 240. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter
BULLETIN NO. 240/11 (SUPERSEDES BULLETIN NO. 240/06) Mid-West Instrument Diaphragm Type Model 240 Hazardous Locations Indicating / Non-Indicating Differential Pressure Switch or Transmitter Field wireable
More information2015 CONTROLLER PRICE LIST Products / Spare Parts / Accessories
W A L C H E M IWAKI America Inc. Controller Price List 2015 CONTROLLER PRICE LIST Products / Spare Parts / Accessories Five Boynton Road Hopping Brook Park Holliston, MA 01746 USA TEL: 508-429-1110 FAX:
More informationFlow Meters & Instruments. Insertion Paddle Wheel & Magnetic Flow Meters Flow & Anaytical Instruments. Technical Catalogue
Flow Meters & Instruments Insertion Paddle Wheel & Magnetic Flow Meters Flow & Anaytical Instruments Technical Catalogue PDF Published October 19, 2017 flow sensors Type F3.01 Direct Mount Flow Sensors
More informationSignet V(D) to V(D) PVDF Conductivity Electrodes
Signet 2839-1V(D) to 2842-1V(D) PVDF Conductivity Electrodes Features ± 2% accuracy - Custom calibration certificate provided Dual-threaded Compact electrode length for easy in-line installation in small
More informationflow x3 flow monitoring
flow x3 flow monitoring The FlowX3 System includes a complete range of paddle wheel flow sensors, instruments and sensor installation fittings. Also included are insertion type electromagnetic flow transmitters.
More informationSOLENOID DRIVEN DOSING PUMPS MX series
SOLENOID DRIVEN DOSING PUMPS MX series www.fwtsystems.it INTRODUCING MX SERIES FWT is pleased to introduce MX solenoid driven dosing pumps, a new series which will enable to widen the product range covering
More informationLow Cost, Low Maintenance Air, Compressed Air and Nitrogen Flow Measurement for Process and Plant Applications
FCI ST50 Series Flow Meters Low Cost, Low Maintenance Air, Compressed Air and Nitrogen Flow Measurement for Process and Plant Applications FCI ST50 FLOW METER Wastewater Treatment Aeration Control Blower
More informationRoyce Total Suspended Solids Systems. Water & Wastewater
Royce Total Suspended Solids Systems Water & Wastewater Portable and Continuous TSS Systems MODEL 711 PORTABLE MLSS/ILA SYSTEM FEATURES Two complete analyzers in one package (TSS & Interface Level) Microprocessor
More informationDirect Automation Trade Price List Process Controls Sensors 1
Direct Automation Trade Price List Process Controls Sensors 1 Sensor & Input Devices Process Controls & Sensors Process/Temperature Controllers & Assessories DPM2-AT-2R-HL ProSense digital panel meter,
More informationPISTON STYLE GAUGE. Mid-West Instrument
PISTON STYLE GAUGE Mid-West Instrument 1 BULLETIN NO. 120/11 (SUPERSEDES BULLETIN NO. 120/02) Mid-West Instrument Piston Type Differential Pressure Gauges Switches & Transmitters Model 120 A low cost differential
More informationMEASURE TODAY. ENSURE TOMORROW. SpireMag Series T-MAG Electromagnetic BTU Meter
MEASURE TODAY. ENSURE TOMORROW. SpireMag Series T-MAG Features The T-MAG BTU meter is the latest addition to the SpireMag series for accurate thermal energy measurement. It utilizes a high accuracy electromagnetic
More informationSignet 4150 Turbidimeter
C L I S T E D 113783 US 4150 Turbidimeter Features Description The 4150 Turbidimeter system provides accurate and reliable compliant water quality monitoring for municipal and industrial applications.
More informationInstrument Enclosure Assemblies
Instrument Enclosure Assemblies Standard instrument enclosure Instrument enclosures offer a simple solution for the customer who doesn t have the time to install Signet meters into panels. Whether it s
More informationAppendix. Clearance. Skewed profiles. Application Schematics
Appendix Application Schematics The purpose of the application schematics is to show different applications and the best sensor location for a particular application. Clearance Because the sensor will
More informationProduct Specifications
PE 100 Metric Piping System Specifications 1. Scope This specification covers requirements for the +GF+ Georg Fischer (later named only +GF+) PE 100 Piping System intended for a wide range of applications
More informationEZ-View Flow Meters. With Flow-Alert TM Flow Switch REDUCE MAINTENANCE COSTS TEL
With Flow-Alert TM Flow Switch Reed switch and latching models Automatically signals alarm if flow is too high or too low Models available for AC or DC power supply Latching models include Hirschmann type
More informationEnvironmental/Analytical LabCivil Engineering Lab Equipment
DIGITAL PH METER Display : 3.5 Digit LED. Range : ph 0 to 14.00, mv 0 to ± 1999. Resolution : ph 0.01, mv 1. : ph ± 0.01, mv ± 1 mv. Temp. Compensation : Auto 0 to 100 deg. C., Manual 0 to 100 deg. C.
More informationPSF50 Paddle flow switch
Paddle Flow Switch Paddle Flow Switch PSF50 Paddle flow switch Paddle flap flow / no flow switch Economically priced flow/no flow paddle operated flow switch. Simple and reliable design for liquids up
More informationMetso Conductivity for sensor series 9400 and 9500
Metso Conductivity Modules 2800 for sensor series 9400 and 9500 Metso Conductivity Modules 2800 Plug-in modules easy service Exchangeable scales with concentration reading Remotely controlled range switch
More informationConductivity meter. PLC Solenoid valve. Type Type On/Off Diaphragm valve. Valve islands
Conductivity meter Configurable outputs: two transistor and single or dual analog 4... 20 ma Removable backlighted display Universal process connection Type can be combined with... Three cell constants
More informationSignet 515 Rotor-X Paddlewheel Flow Sensors
Signet 515 Rotor-X Paddlewheel Flow Sensors Features Operating range 0.3 to 6 m/s (1 to 20 ft/s) Wide turndown ratio of 20:1 Highly repeatable output Simple, economical design Installs into pipe sizes
More informationTX 115/215 Hot-tap Insertion Turbine Instructions
TX 115/215 Hot-tap Insertion Turbine Instructions General Information These hot tap versions of the proven TX insertion flow sensors are designed to install or be serviced without depressurizing the pipe.
More informationAutomation Made Easy 2013 Signet Measurement and Control Product Catalog
Multi-Parameter Chlorine Dissolved Oxygen Turbidity Flow ph/orp Conductivity/Resistivity Temperature Pressure Level Automation Made Easy 2013 Signet Measurement and Control Product Catalog Automation Made
More informationFCI ST50 Series Flowmeters Low Cost, Low Maintenance Air, Compressed Air and Nitrogen Flow Measurement for Process and Plant Applications
FCI ST50 Series Flowmeters Low Cost, Low Maintenance ir, Compressed ir and Nitrogen Flow Measurement for Process and Plant pplications Wastewater Treatment eration Control lower and Dryer ir Flow Control
More informationTX115/215 Hot-tap Insertion Turbine Instructions
TX115/215 Hot-tap Insertion Turbine Instructions General Information These hot tap versions of the proven TX insertion flow sensors are designed to install or be serviced without depressurizing the pipe.
More informationABB MEASUREMENT & ANALYTICS DATA SHEET. TBX5 ph, Redox (ORP) sensors with diagnostics
BB MESUREMENT & NLYTICS DT SHEET TBX ph, Redox (ORP) sensors with diagnostics Measurement made easy The most durable ph / Redox (ORP) sensors in the world Next Step Solid State reference eliminates poisoning,
More informationFrom. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951)
SPI Mag MODEL 282L SINGLE POINT INSERTION ELECTROMAGNETIC FLOW METER 2 SENSOR SUBMITTAL PACKAGE From McCROMETER, INC. 3255 WEST STETSON AVENUE HEMET, CA 92545 Phone (951) 652-6811 Toll Free (800) 220-2279
More informationFPI-X FULL PROFILE INSERTION ELECTROMAGNETIC FLOW METER MODEL 395X MAG METER SUBMITTAL
FPI-X FULL PROFILE INSERTION ELECTROMAGNETIC FLOW METER MODEL 395X MAG METER SUBMITTAL From McCROMETER 3255 WEST STETSON AVENUE HEMET, CA 92545 Phone (951) 652-6811 Toll Free (800) 220-2279 Fax (951) 652-3078
More informationSignet 2536 Rotor-X Paddlewheel Flow Sensors
Signet 2536 Rotor-X Paddlewheel Flow s Features Operating range 0.1 to 6 m/s (0.3 to 20 ft/s) Wide turndown ratio of 66:1 Open-collector output Highly repeatable output Simple, economical design PVC (gray
More informationMid-West Instrument. Piston Type Differential Pressure Gauges Switches & Transmitters Model 123
BULLETIN NO. 123/11 (SUPERSEDES BULLETIN NO. 123/03) Piston Type Differential Pressure Gauges Switches & Transmitters A low cost differential pressure gauge for use in measuring the pressure drop across
More informationF-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)
F-1500 SERIES INSERTION TURBINE FLOW METER Insertion turbine flow meters are ideal for use in larger steam lines where downsizing the line size to improve flow measurement is not desirable. In these applications,
More informationLow Cost Submersion and In-Line ph Electrodes
Low Cost Submersion and In-Line Electrodes Economical design for in-line or submersion use Choose from single or double models Threaded 1/2" or 3/4" NPT connections Choose from spherical or flat measuring
More informationIsoil Industria a worldwide supplier of electromagnetic flowmeters Total flow control. Accurate to the drop.
www.isomag.eu Isoil Industria a worldwide supplier of electromagnetic flowmeters Total flow control. Accurate to the drop. 1 THE IDEAL FLOWMETERS FOR ANY APPLICATION from DN03 to DN2400 wide range of process
More informationElectromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids
Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids For use in large diameter pipes as an economical solution for flow measurement Flow rate measurement
More informationELPRO Lepenik & Co. d.o.o., Ob gozdu 7c, Rogoza, 2204 Miklavž na Dravskem polju, Slovenija tel:
ph & Conductivity The following pages contain a variety of instruments for the measurement of ph values as well as conductivity in microsiemens. PHX 800 as a standard testing device for the ph values.
More informationSIGNET 3719 ph/orp Wet-Tap
ENGLISH 3-3719.090 B-6/02 English Do not exceed maximum temperature/pressure specifications. Wear safety goggles or face shield during installation/service. Do not attempt to disassemble the retraction
More informationSmartBob II SBR.1 A M1 H X X XX. Base. Mounting Plate. Cable. Heater. Probe
SmartBob II Base Mark X if none Sample Sample SBR.1 A 1 035 M1 H X X XX Cable Probe Mounting Plate Heater Cable Length (begin with 0 if less than 100 ft.) Entered in feet up to 150 feet Cable Type 1: C1
More informationOD DISSOLVED OXYGEN METER
UNI EN ISO 9001:2000 CERT. N. 9115 BCEL INSTRUCTION MANUAL OD 205.2 DISSOLVED OXYGEN METER Rev. B - 03/07 B&C Electronics Srl - Via per Villanova 3-20040 Carnate (Mi) - Italy - P.IVA 00729030965 Tel +39
More informationLow Profile Insertion Vortex
Low Profile Insertion Vortex Product Features The same insertion meter can measure Steam, Gases or Liquids. Standardize on an insertion bar that can measure line sizes 2 24 Heavy Duty & Maintenance Free
More informationOD DIGITAL DISSOLVED OXYGEN CONTROLLER POLAROGRAPHIC CELL
UNI EN ISO 9001:2000 CERT. N. 9115 BCEL INSTRUCTION MANUAL OD 265.2 DIGITAL DISSOLVED OXYGEN CONTROLLER POLAROGRAPHIC CELL Rev. B - 03/07 B&C Electronics Srl - Via per Villanova 3-20040 Carnate (Mi) -
More informationProduct Specifications
SYGEF Plus PVDF HP Metric Piping System Specification 1. Scope This specification covers requirements for the +GF+ Georg Fischer (later named only +GF+) SYGEF Plus PVDF HP Piping System intended for a
More informationGF Signet. Measurement & Control Sensors. Signet Price List 1st Aug 2011 Rev 0.0
GF Signet Measurement & Control Sensors Sensors and Transmitters: Flow ph Conductivity ORP Level Pressure Temperature Turbidity Chlorine Installation fittings Power supplies Calibration solutions Accessories
More informationPN October Liquid Division. Mounting Solutions
PN 91-6020 October 2001 Liquid Division Mounting Solutions INTRODUCTION: Rosemount Analytical, Inc, Uniloc Division is pleased to offer a variety of sensor mounting options to fit many demanding process
More informationIndustrial Meter Catalog
Industrial Meter Catalog SEE INSIDE FOR THESE NEW PRODUCTS: GBM Series Mini Batcher... page 66 LM50M Mechanical Lube Meter... page 52 TM Digital Pulse Meter... page 53 VERSION 6 2008 888-996-3837 www.gpi.net
More informationGeneral Information... Temperature/Resistance Table... Part Numbering Examples for RTD s. High Temperature MgO Elements (RA)...
Page General Information... Temperature/Resistance Table... Part Numbering Examples for RTD s High Temperature MgO Elements (RA).... Leadwire Style RTD s (RB).. Leadwire Style RTD s (RD, RE, RF, or RG
More information