100 to 400 MPa Series
|
|
- Gregory Frederick Snow
- 6 years ago
- Views:
Transcription
1 100 to 400 Series 100 Pumps 202 Accessories Single-Acting Cylinders 204 Double-Acting Cylinders 205 Manual Pumps 206 SMP Electric Pumps 208 Special Pumps 209 Valves 210 to 212 Pressure Switches/ Pressure Gauges 213 Hoses/Couplers 214 Branches 215 Joints /400 Manual Pumps/Pressure Gauges
2 Pumps (100 ) Manual Pumps (UP Series) Manual pumps with a maximum operating of 100 feature the two-stage speed control by which the automatically switches between high and low speed modes. Compact and light because all necessary valves such as a safety valve, air valve, and operating valve included, and an oil tank is incorporated. code structure UP UP-11 Hydraulic circuit diagram UP-11/UP operating High Series No series Ultrahigh- manual pump Discharge cm 3 /stroke Low At high At low Outlet port Rc Hydraulic oil Tank oil cm 3 Effective oil cm 3 Lever load N (At 100 ) UP /8 ISO VG32 UP * The oil tank is filled up with hydraulic oil before shipment. * As an optional extra, the gauge mounting bracket (T-5-1K) is available. UP-11 UP-12 Pumps Accessories Electric pumps (MP-1000 Series) Make-to-order product code structure MP MP : For single-acting cylinders 4C : For double-acting cylinders 100 series High- electric pump Motor 50/60 Hz Pump 50/60Hz Oil tank Type Voltage (No. of phases) Output kw Number of revolutions rpm operating Discharge Hydraulic oil Tank oil L Effective oil L Attached operating valve MP Fully-enclosed 200 V 40 SMV-33-1K fan-cooled type / /0.45 ISO VG MP C with small flange (3 phases) 41 SMV-43-1K *The oil tank is filled up with hydraulic oil before shipment. Hydraulic circuit diagram MP (C) MP No. Name Notes 1 Oil tank 4 Motor 5 Electric magnetic switch 6 Start switch 13 High- safety valve 18 Pressure switche PCS Direction-control valve SMV-33-1K 27 Air valve 34 Oil drain port Rc3/8 35 Return port Rc3/8 36 Outlet port Rc3/8 37 Fill port Rc3/4 * The above numbers do not correspond to the part numbers of the product. For the part numbers of the product, see the operation manual. 202
3 Accessories (100 ) High-Pressure Nylon Hoses (UH03 Series) 100 With R (male) threaded joints at both ends. Basically used with an H type coupler on one of its sides. *For precautions for and maintenance of high- hoses, see page 179. Do not hold a high- nylon hose while is applied. If the hose is broken while held by hand, the high- hydraulic oil could spurt and cause severe injury, for example, a pierced hand. Before work starts, check the following: damage to the hose, swelling of the hose (sheath), exposure of the reinforced layer (external damage), bent (deformation), leakage from the joints, etc. If any of the above problems is found, replace the hose with new one immediately because the use of a damaged hose is dangerous. Even if there are no abnormalities in appearance, there may be scratches, pinholes, etc. inside the hose. Replace the hose regularly taking the operating conditions into account. UH03-1NC code structure UH 03-1 NC UH03 Overall length (m) Thread size 03 : R3/8 High- nylon hose Attached coupler Blank : With HS-1H on one side W : With HS-1Hs on both sides* NC : No couplers The hose marked * is filled with the hydraulic oil before shipping unless otherwise specified. Pumps Accessories Operating Thread Internal Standard Expansion Minimum operating temperature overall Volume range Hydraulic oil Material size diameter length bend radius C R ϕ m cm 3 /m cm 3 /m mm /m UH to 80 (Note 1) Couplers (HS Series) General hydraulic oil (mineral-based hydraulic oil) Nylon 3/8 6.3 The HS-1 models are a self-sealing type that prevents oil leakage. A duster cap (made of resin) is attached to all models. Do not apply to the H type or R type coupler alone. Otherwise, the equipment may be damaged. It is dangerous to connect or disconnect the couplers while is applied. Doing so may allow compressed oil to flow out, causing injury. 1/2/3 6/ (Note 1) The operating temperature range shown above can be applied to the hose alone. (Note 2) The approx. represents the of the hose alone. It does not include the joints at both ends and the protection. HS-1R Securely and completely connect the couplers. Not doing so could cause not to rise, the hydraulic oil not to flow, or other problems. If the fluctuates often or vibration is transmitted to the couplers, regularly check the looseness of the cap nut. If a cylinder that works normally stops suddenly, the most likely cause is looseness (a gap) between the couplers. Tighten the couplers again using a tool if a gap exists. A duster cap is included with a coupler. Attach the cap to the coupler after use to prevent dust. HS-1H External drawing of couplings (HS-1) HS-1R code structure HS - 1 R High- coupler Thread size 1 : 3/8 HS-1H 0.3 (Note 2) R : Cylinder side coupler H : Hose side coupler operating Operating fluid Operating fluid temperature range C Accessory (duster cap) HS-1R General 0.13 S-1R-DC to 60 HS-1H hydraulic oil 0.12 S-1H-DC Joints (FMSH Series) FMSH-M22 x 3/8 FMSH-3/8 x M22 (coupled couplers) code structure FMSH - M22 x 3/8 Female thread size High- male-and-female socket operating FMSH-M22 x 3/ FMSH-3/8 x M Male thread size 203
4 Single-Acting Cylinders (200 ) 300 to 1000 kn (US Series) code structure US 3-50 output 3 : 300 kn US Series 5 : 500 kn 10 : 1000 kn US5-50 Stroke (mm) US3-50/US5-50 operating output Cylinder system Return system Attached coupler /500/1000 kn Single-acting Spring-return type S-4R Coupler connection port size M22 x 1.5 US5-100/US5-150/US10-50/US US3-50 US5-50 US5-100 US5-150 US10-50 US output kn Effective area cm Stroke mm Minimum overall length A Cylinder internal diameter ϕ Cylinder external diameter ϕ C Piston diameter ϕ D Piston thread size E M34 x 2 M50 x 2 M65 x 2 Cap diameter ϕ F Piston protrusion length I Coupler protrusion length S Coupler position T Required oil cm to 3000 kn (ULF Series) The piston is allowed to be inclined at a maximum angle of 4. ULF10-10 code structure ULF ULF Series output Stroke (mm) 10 : 1000 kn 15 : 1500 kn 20 : 2000 kn 30 : 3000 kn ULF10-10 ULF15-10 ULF20-10 ULF30-10 output kn Effective area cm Stroke mm Minimum overall length A Cylinder internal diameter ϕ Cylinder external diameter ϕ C Piston diameter ϕ D Coupler protrusion length S Coupler position T Required oil cm operating output Cylinder system Return system Attached coupler /1500/2000/3000 kn Single-acting Load-return ROC-2K-R Coupler connection port size M14 x 1.5 ULF Use the whole surface of the cylinder bottom on hard flat plane so that the jack supports the load stably. The ULF series cylinders have no piston stop ring. If the piston advances 10 mm or more (when the stroke-end indicating groove appears), it will be ejected causing oil leakage. Moreover the cylinder may need repair. Cylinders Pumps Valves Accessories
5 Double-Acting Cylinders (200 ) 300 to 2000 kn (UD Series) 200 code structure UD operating on the push side operating on the pull side output 3 : 300 kn UD series 5 : 500 kn 10 : 1000 kn 20 : 2000 kn Stroke (mm) Cylinder system Double-acting Attached coupler S-4R Coupler connection port size M22 x Accessories Valves Pumps Cylinders UD3-125 UD Push side Pull side UD5-150 Internal drawing *The cylinder has a safety valve for the pull side (preset : 20 ). A modification is required if the pull side is used for operation. *The structures and parts differ depending on the model. Please contact us for internal drawings of other models. UD3-125 UD5-150 UD UD UD output kn Effective area cm output kn Effective area cm Stroke mm Minimum overall length A Cylinder internal diameter ϕ Cylinder external diameter ϕ C Piston diameter ϕ D Piston thread size E M30 x 2.0 M40 x 1.5 M52 x 2.0 M84 x 3.0 Piston thread length G Piston protrusion length I Collar thread size M M75 x 2.0 M95 x 2.0 M127 x 2.5 M185 x 3.0 Collar thread length N Coupler protrusion length on the push side S Coupler position on the push side T Coupler protrusion length on the pull side V Coupler position on the pull side W No. Part name Q ty 11 Cylinder tube 1 12 Piston 1 14 Piston stop ring 1 61 O-ring 1 63 O-ring 1 64 O-ring 1 71 Backup ring 2 73 Backup ring 1 74 Backup ring 1 77 Backup ring 2 81 Dust seal 1 91 Coupler Socket Spring Adjustment screw Ball seat Solid carbide ball O-ring Backup ring Backup ring Backup ring Hexagon socket set screw 2 Distance between the ports Y Required oil cm to 2000 kn Caps (UD Series) Make-to-order product ϕ A B C 300 kn cap M30 x kn cap M40 x kn cap M52 x kn cap M84 x
6 Manual Pumps (200 ) Ultrahigh-Pressure Manual Pumps (UP Series) code structure UP - 21 M - U Hydraulic circuit diagram UP-21M-U Hydraulic circuit diagram UP-22B-U/UP-22M-U 200 Series No. Ultrahigh- manual pump UP-22B-U U : With gauge mounting bracket T (B) 21 M : For single-acting cylinders (Outlet port M14 x 1.5) 22 B : For single-acting cylinders (Outlet port M22 x 1.5) D : For double-acting cylinder (Outlet port M14 x 1.5) Hydraulic circuit diagram UP-21D-U Hydraulic circuit diagram UP-22D-U operating Discharge cm 3 /stroke High Low At high At low 200 Outlet port Hydraulic oil Tank oil cm 3 UP-22B-U/UP-22M-U Effective oil cm 3 Lever load N (At 200 ) Attached operating valve UP-21M-U M14 x UP-21D-U 9.8 SMVT-2K-4 UP-22B-U M22 x 1.5 ISO VG UP-22M-U M14 x 1.5 UP-22D-U 20.2 SMVT-2K-4 The oil tank is filled up with hydraulic oil before shipment. UP-21M-U UP-21D-U *The dimensions in parentheses are of the UP-22B-U. UP-22D-U Cylinders Pumps Valves Accessories 300 Any old models of gauges with a fixed joint cannot be mounted. Instead, use the gauge with a universal joint (see page 213). 206
7 Small-Size Portable Electric Pumps (200 ) Small-Size Portable Ultrahigh-Pressure Electric Pumps (SMP-200 Series) 200 With a magnet motor, noise is reduced greatly as compared with that of conventional models. The durability has also been improved. Light, compact, and easy to handle. Ideal for field work such as shipbuilding and civil engineering construction. Due to the two-stage speed control, the automatically switches between high and low speed modes for better work efficiency. All models have an M outlet port. A special switch is mounted on each model. code structure SMP B - A SMP B Tank capacity Attached gauge 2 : 2.0 L Blank : ASBG M-U 4 : 4.5 L A : ASG M-U Motor voltage 6 : 6.5 L N : W/O gauge 1 : 100 V Attached valve 200 series 2 : 200 V B : For single-acting cylinders Small-size portable ultrahigh- electric pump 3 : 230 V C : For double-acting cylinders SW-4A *No certificates can be issued for the ASBG M-U gauge. Accessories Valves Pumps Cylinders SMP B(C) Type E closed-type magnet motor (50/60Hz) Pump Oil tank Voltage V (single phase) Rated output kw Rated operating time min Current A *1 operating High Low Discharge At high At low Hydraulic oil Tank oil L Effective oil L SMP B(C) SMP B(C) SMP B(C) ISO VG SMP B(C) * SMP B(C) SMP B(C) The SPS-2K switch is exclusively used for the SMP-200 series. If the switch is used with other products, please contact us. If the pump is used continuously, observe the rated operating time (5 minutes) and take care of the increase in motor and oil temperatures. Otherwise, the equipment may be damaged resulting in poor performance SMP B(C) SMP B(C) *1. Each current shown above is the average of the load currents at 200. *2. Each of the double-acting cylinder (C) models is about 1 heavier than the corresponding approx. shown above. The oil tank is filled up with hydraulic oil before shipment. SMP B (22B/32B) SMP-200-*B hydraulic circuit diagram 300 SMP-200-*C hydraulic circuit diagram 207
8 Electric Pumps (200 ) Ultrahigh-Pressure Electric Pumps (MP-2000 Series) Make-to-order product Thanks to a high-performance axial piston system, the series features very small changes in discharge caused by fluctuation. Equipped with a double safety mechanism using a safety valve and switch to prevent an overload. code structure MP C MP /8 hydraulic circuit diagram series Ultrahigh- Electric pump Blank : For single-acting cylinders C : For double-acting cylinders Series No. 4 8 MP MP C/8C hydraulic circuit diagram Type Motor (50/60 Hz) Pump Oil tank Voltage (No. of phases) Output kw Number of revolutions rpm operating Discharge (50/60Hz) Hydraulic oil Tank oil L Effective oil L Attached operating valve MP /0.42 MP C Fully-enclosed 200 V 117 HOV / ISO VG MP fan-cooled type (3 phases) /1.08 MP C 137 HOV The oil tank is filled up with hydraulic oil before shipment. MP MP Cylinders Pumps Valves Accessories 300 No. Name Notes No. Name Notes 1 Oil tank 27 Air breather 4 Motor 29 Oil level gauge 5 Electric magnetic switch 34 Oil drain port Rc3/8 6 Push-button switch 35 Return port Rc3/8 13 High- safety valve 36 Outlet port M22 x Pressure switch PCS Refill port Rc3/4 24 Operating valve * The above numbers do not correspond to the part numbers of the product. *Power cable length 2.5 m For the part numbers of the product, see the operation manual. Any old models of gauges with a fixed joint cannot be mounted. Instead, use the gauge with a universal joint (see page 213). 208
9 Special Pumps (200 ) Esperpack (AMP-2000 Series) Make-to-order product 200 The latest automatic control hydraulic equipment developed drawing upon the know-how and experience accumulated based on the 70 series that has been proven in the market, capable of highly accurate control up to 200. Esperpack can meet demands, such as controlling the linearly in proportion to time and maintaining the precisely for a long time, and can be used with simple operation. Always monitoring the present, this unit automatically corrects the even if there is a disturbance factor like a hot press or a device for deformation testing of an elastic material, which fluctuates. The pump applies only the required when it is necessary, and the proportional reducing valve reduces only the unnecessary. For this reason, the energy loss is small and no oil cooler is needed, resulting in excellent low-noise property and durability. AMP-2000 LCD touch panel control screen Pumps Cylinders Ultrahigh-Pressure Air Hydraulic Pump (ON-15-2K) Valves Accessories 300 The pump piston is operated by using the air source to generate 200 hydraulic. Light, compact, and easy to operate. A 30PM coupler with a duster cap made by Nitto Kohki is attached to the air connection port. An FRL unit (regulator, filter, and lubricator) is necessary to use the pump. Supply air operating Discharge cm 3 /min Oil tank Under no load Tank oil Effective oil At 200 Hydraulic oil condition cm 3 cm 3 ON-15-2K 0.45 to ISO VG ON-15-2K ON-15-2K Performance characteristics 209
10 Valves (200 ) 4-Way 3-Position Direction-Control Valves (SMVT/HOV-2000 Series) The SMVT-2K is used with manual pumps(up-21/up-22 series) for double-acting cylinders. The HOV-2000 is used with electric pumps(mp-2000 series) for double-acting cylinders. SMVT-2K-4 SMVT-2K-4 HOV HOV SMVT-2K-4 HOV operating flow rate 2-Way Solenoid Valves (SL-2K Series) Connection port size Return port Rc Allowable back SMVT-2K M14 x 1.5 1/ HOV M22 x 1.5 3/8 4.5 Since the coil has a continuous rating, electric power can be applied for a long time. Oil leakage is extremely small because the valve is a poppet type. Durable and reliable because the valves are a -balanced type. Pressure can be applied to both primary and secondary sides. 24 VDC models are make-to-order products. *For the solenoid specifications, see page 223. * The connectors are dedicated to one of 100 V, 200 V, or 24 VDC. SL-2K-2 SL-2K-2 hydraulic symbol SL-2K-2C hydraulic symbol code structure SL - 2K series Solenoid power supply 1 : 100 V SL series (2-way valve) 2 : 200 V DC24 : 24 VDC 2 : Normally open 2C : Normally closed SL-2K Cylinders Pumps Valves Accessories 300 SL-2K-2-1 SL-2K-2-2 SL-2K-2-DC24 SL-2K-2C-1 SL-2K-2C-2 SL-2K-2C-DC24 Hydraulic symbol name Normally open Normally closed operating flow rate Connection port size M22 x 1.5 Power 100 VAC 200 VAC 24 VDC 100 VAC 200 VAC 24 VDC Accessory Mounting bolts: MBH-60 (4 pcs) 7.5 *The SL-2K-2-DC24V and SL-2K-2C-DC24 are make-to-order products. 210
11 Valves (200 ) Shutoff Valve (V B) 200 Used to open/close a circuit. Uses a mechanism that allows smooth handle operation even during pressurization. Turning the handle clockwise closes the pipe line. V B V B V B operating flow rate Connection port size V B M22 x Cylinders Check Valve with Bypass (CH B) The flow goes from port 1 to port 2. It can be reversed by opening the bypass side. Turning the handle clockwise throttles the bypass line. CH B CH B CH B Accessories Valves Pumps 300 operating flow rate Cracking Connection port size CH B M22 x Inline Check Valve (CH B) Allow oil to flow in one direction at the cracking or higher to prevent a reverse flow. CH B CH B CH B operating flow rate Cracking Connection port size CH B M22 x
12 Valves (200 ) Pilot Controlled Check Valve (CH ) Enables a reverse flow by applying 1/30 of the secondary-side to the pilot port. Generally, if the primary side is pressurized, the check valve cannot be opened. CH CH CH operating flow rate Pilot area ratio Cracking Connection port size Pilot port size Rc CH * :1 0.3 M22 x 1.5 3/8 8 *The maximum operating of a pilot circuit is 70. Relief Valve (RV B) Fewer fluctuations are an advantage. For adjustment, loosen the lock nut first. To increase the, turn the handle clockwise gradually. To reduce the, turn it counterclockwise. After adjustment, be sure to tighten the lock nut. RV B operating Needle Valve (NV B) flow rate RV B Pressure setting range RV B Allowable back Connection port size Return port Rc RV B to M22 x 1.5 3/8 2.3 NV B NV B The hydraulic oil passage can be throttled for flow adjustment using the needle. As the temperature or changes, the flow rate also changes. Turning the handle clockwise throttles the pipe line. NV B Cylinders Pumps Valves Accessories 300 operating flow rate Connection port size NV B M22 x
13 Pressure Switch/Pressure Gauge (200 ) Pressure Switche (PCS-2000) 200 For installation, use a GC-2000 gauge cone and a T1-2000(B) gauge mounting bracket. The can be set easily without a tool. Because a universal joint is used, users can select the desired display orientation. PCS-2000 PCS-2000 PCS-2000 Terminal names operating Pressure setting range dead band Contact capacity Connection port size PCS to V, 6A G1/2 universal joint 2.3 Cylinders Pumps Valves Pressure Gauges Can be mounted in a narrow place thanks to the universal joint. The ASBG M-U and ASG M-U are silicone-containing gauges that are resistant to surge and a sudden fluctuation. Calibration and traceability certificates cannot be issued for the AS- BG M-U because of its special internal structure. If the certificates are required, choose the ASG M-U or AS M-U. The AS M-U can be mounted on the gauge mounting bracket without a GC-2000 cone, because the gauge uses a mounting part with the cone. The ASG M-U is a make-to-order product. ASBG M-U Hydraulic symbol ASBG M-U code structure AS M - U scale () Nominal diameter (ϕ mm) Pressure gauge AS : Standard type (certificates available) U : Universal joint ASBG : Silicone-containing type (certificates not available) ASG : Silicone-containing type (certificates available) Mounting Accessories 300 AS M-U ASG M-U operating scale Minimum scale Accuracy F.S. Thread size Certificates Not available 0.8 Available 1.0 ASBG M-U 2 Equivalent to ±2.5 % G1/2 AS M-U ±1.6% universal joint ASG M-U 2 Available 0.8 *The accuracy of the ASBG M-U is a reference value. 213
14 Ultrahigh-Pressure Hoses/Ultrahigh-Pressure Couplers (200 ) Ultrahigh-Pressure Nylon Hoses (UH14/UH22 Series) Ultrahigh- hoses with a maximum operating of 200. Two types of thread sizes, M22 x 1.5 and M14 x 1.5 are available. * For precautions for and maintenance of ultrahigh- hoses, see page 179. operating Operating temperature range C Couplers (S-4/ROC-2K Series) Hydraulic oil Material Thread size code structure UH 14-1 Overall length (m) Blank : With coupler on one side UH14 : With ROC-2K-H Thread size UH22 : With S-4H 14 : M14 x 1.5 W : With couplers on both sides 22 : M22 x 1.5 UH14 : With ROC-2K-H* UH22 : With S-4H* Ultrahigh- nylon hose NC : No couplers *The hoses marked * are filled with the hydraulic oil before shipping unless otherwise specified. UH14-40 to 50 General M14 x 1.5 1/2/3 200 Plastic UH22 (Note 1) hydraulic oil M22 x 1.5 6/ Note 1. The operating temperature range shown above can be applied to the hose alone. Note 2. The approx. represents the of the hose alone. It does not include the joints at both ends and the protection. UH14 S-4 Do not hold an ultrahigh- nylon hose while is applied. If the hose is broken while held by hand, the high- hydraulic oil could spurt and cause severe injury, for example, a pierced hand. Before work starts, check the following: damage to the hose, swelling of the hose (sheath), exposure of the reinforced layer (external damage), bent (deformation), leakage from the joints, etc. If any of the above problems is found, replace the hose with new one immediately because the use of a damaged hose is dangerous. Even if there are no abnormalities in appearance, there may be scratches, pinholes, etc. inside the hose. Replace the hose regularly taking the operating conditions into account. UH14 UH22 operating Operating fluid Dimensions of couplings (S-4) UH22 Operating fluid temperature range C 0.4 S-4R S-4 0 to 60 S-4H General hydraulic oil ROC-2K ROC-2K-R to 100 ROC-2K-H 0.2 S-4R Standard overall length m Hydraulic symbol (coupled couplers) Volume cm 3 /m Expansion cm 3 /m Minimum bend radius mm code structure S-4 R /m 0.3 (Note 2) *The dimension in parentheses is of when the overall length of the hose is 1 m. Coupler R : Cylinder side coupler S-4 H : Hose side coupler ROC-2K S-4H 200 Cylinders Pumps Valves Accessories 300 ROC-2K Dimensions of couplings (ROC-2K) ROC-2K-R ROC-2K-H *When the ROC-2K couplers are attached, the special joint (NU-14) may be needed (see page 216). Pressure must not be applied to a ROC-2K-R coupler alone. Otherwise, the equipment may be damaged. It is dangerous to connect or disconnect the couplers while is applied. Doing so may allow compressed oil to flow out, causing injury. Securely and completely connect the couplers. Not doing so could cause not to rise, the hydraulic oil not to flow, or other problems. If the fluctuates often or vibration is transmitted to the couplers, regularly check the looseness of the cap nut. If a cylinder that works normally with S-4 couplers stops suddenly, the most likely cause is looseness (a gap) between the couplers. Tighten the couplers again using a tool if a gap exists. A duster cap is included with a coupler. Attach the cap to the coupler after use to prevent dust. 214
15 Branches (200 ) Branches for One Circuit 200 Used to branch one hydraulic circuit. operating Hydraulic oil No. of outlets Accessory B Hexagon socket 3.3 head bolt: B General M6 x 60 (4 pcs) B Base (2 pcs) 6.0 hydraulic oil B B *The B4-2000, B5-2000, and B are make-to-order products. B B B code structure B No. of outlets Branches for one circuit 200 series B Cylinders Pumps Valves Any old models of gauges with a fixed joint cannot be mounted. Instead, use the gauge with a universal joint (see page 213). Branches with Shutoff Valve for One Circuit Make-to-order product Used to branch one hydraulic circuit. operating Hydraulic oil No. of outlets BV BV General BV hydraulic oil BV BV BV BV BV code structure BV No. of outlets 200 series Branches with shutoff valve for one circuit Accessories BV Any old models of gauges with a fixed joint cannot be mounted. Instead, use the gauge with a universal joint (see page 213). Branches with Shutoff Valve for Two Circuits Make-to-order product Used to branch two hydraulic circuits. code structure BW BW BW series No. of inlets Branches with shutoff valve for two circuits operating BW Hydraulic oil General hydraulic oil Accessory Mounting bolts: M6 x 85 (4 pcs) Base (2 pcs) Any old models of gauges with a fixed joint cannot be mounted. Instead, use the gauge with a universal joint (see page 213)
16 Joints (200 ) Piping Parts (Pressure Gauge Mounting Bracket/Joints) operating : 200 T1-2000(B) Pressure gauge mounting bracket EN-2000 equal nipple NU-14 x 22 reducing nipple 200 FMSU-G1/2 x M34 conversion bushing : 0.7 : 0.2 : 0.1 EA-2000 sleeve NU-14 nipple U-2000 socket : 0.1 : 0.01 : 0.05 EB-2000 bushing FMSU-22 x 14 male-and-female socket L-2000 elbow T-2000 tee X-2000 cross : 0.2 : 0.04 : 0.1 ED-2000 plug Steel pipe with ends processed Steel pipe FMSU-14 x 22 male-and-female socket : 0.4 : 0.08 : 0.1 SU-14 socket : 0.6 : 2.4 /3 m : 0.06 PU-14 plug Cylinders Pumps Valves Accessories 300 Details of Piping Threads M22 female thread machine drawing : 1.0 : 2.4 /3 m : 0.05 Any old models of gauges with a fixed joint cannot be mounted on the T1-2000(B) gauge mounting bracket. Instead, use the gauge with a universal joint (see page 213). ϕ 12 pipe thread machine drawing Coupling drawing (M22 thread) M14 female thread machine drawing 216
17 300 Ultrahigh-Pressure Manual Pumps (UP-31/UP-41 Series) 200 Can boost the up to 300/400 (ultrahigh-). Due to the two-stage speed control, the automatically switches between high and low speed modes for better work efficiency. Equipped with a safety valve like the reliable 70 and 200 series. Calibration and traceability certificates cannot be issued for the ASBG M-U (mounted on the UP-31) because of its special internal structure. code structure UP - 31 B UP-31B Cylinders Series No. 31 : For : For 400 Ultrahigh- manual pump UP-31 UP-31B Pressure gauge operating High 300 Blank : With gauge (ASBG M-U) *UP-31 only B : Without gauge Discharge cm 3 /stroke Low At high At low Outlet port Hydraulic oil Tank oil cm 3 Effective oil cm M16 x 1.5 ISO VG Lever load UP-41B UP-31 UP-31B/UP-41B N Valves Pumps Accessories UP-31 hydraulic circuit diagram UP-31B/UP-41B hydraulic circuit diagram 300 /400 Pressure Gauges *The in parentheses is the preset for the UP-41B. Can be mounted in a narrow place thanks to the universal joint. The ASBG M-U is a silicone-containing gauge that is resistant to surge and a sudden fluctuation. Calibration and traceability certificates cannot be issued for the ASBG M-U because of its special internal structure. If the certificates are required, choose the AS M-U or AS M-U. The AS M-U and AS M-U are make-to-order products. operating scale Accuracy F.S. Thread size Certificates Compatible pump ASBG M-U 5 Equivalent to ±4.0 % Not available G1/2 UP-31 AS M-U 10 Available 1.1 ±1.6 % universal joint AS M-U Available UP *The accuracy of the ASBG M-U is a reference value. 217
Compact direct acting precision regulator
direct acting precision Components preparation and pressure adjustment / unit CONTENTS Product introduction 6 Safety precautions 62 Discrete (RJB500) 624 Block manifold (MNRJB500) 626 Block configurations
More informationSeries VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4
Type of actuation 4 Piping 0 Side ported Bottom ported 4 Without sub-plate Large Size 5 Port Solenoid Valve Rubber Seal Series 50/4 70 Series VP 5 port solenoid valve 5 7 position single position double
More informationHydraulic Jacks & Tools Valves
Hydraulic Jacks & Tools Valves VH-4/3-1 with VSM-21 VH-4/3-1 VH-3/3-1 VH-4/3-2 VHH-4/3 This port can easily be used to connect a pressure gauge and a pressure relief valve (e.g. VR-1). The oil port T shall
More informationDetails of Special Threads
Details of Special Threads NS threads (Male) Male External Pitch Minor For 40 kn 1 1/2-16NS For 100 kn 2 1/4-14NS 38.1 57.15 84.14 37.06 55.97 82.76 36.15 54.92 81.54 For 200 kn 3 5/16-12NS Angle 60 NS
More informationV Series AXIAL PISTON PUMP ORDER CODE
V Series AXIAL PISTON PUMP ORDER CODE V A 1 R B S - A D X A 1 Customers demand Pump Series V Links Type (only V -18): none - Standard A - SAE A bolts Ma. (cm 3 /n):, 18, 3,, 38, 4,, 7 Pump Control Type
More informationDiaphragm Valve Type 14 Pneumatic Model Type AV
ASAHI AV Valves Serial No. H A015 E 1 Diaphragm Valve Type 14 Pneumatic Model Type AV User s Manual (1) General operating instructions Contents (2) General instructions for transportation, unpacking and
More informationROD SLIDERS INDEX ACTUATORS GENERAL CATALOG. Characteristics 779. Handling Instructions, and Precautions 783
Presenting our CAD drawing data catalog ACTUATORS GENERAL CATALOG ROD SLIDERS INDEX Characteristics 779 Handling Instructions, and Precautions 783 Standard Cylinders Specifications 785 Order 78 Dimensions
More information3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option.
3 Port Solenoid Valve Direct Operated Poppet Type Series VT325 Rubber Seal [Option] Note) Applicable only for DIN terminal type. Compact yet provides a large flow capacity Dimensions (W x H x D) 55 x 118
More informationTPV Variable Displacement Closed Loop System Axial Piston Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 852 / 0815 / E
HYDRAULIC COMPONENTS HYDROSTATIC TRANSMISSIONS GEARBOXES - ACCESSORIES Certified Company ISO 9001-14001 ISO 9001 Via M. L. King, 6-41122 MODENA (ITALY) Tel: +39 059 415 711 Fax: +39 059 415 729 / 059 415
More information3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option
3 Port Solenoid Valve Direct Operated Poppet Type VT317 Series Rubber Seal [Option] Note) CE-compliant: Electrical entry is applicable only for the DIN terminal. Compact yet provides a large flow capacity
More informationPD3/PDV3-20A/25A/40A Series
Pilot operated 2-port valve for dust collector control (Large port size dust collector valve) PD3/PDV3-20A/25A/40A Series Air operated/with solenoid valve Port size: Rc3/4, Rc1, : Rc1 1 /2-: φ48, Rc1 1
More informationV Series AXIAL PISTON PUMP ORDER CODE
V Series AXIAL PISTON PUMP ORDER CODE V 15 A 1 R B S - A 1 D X A 11 Customers demand Pump Series V Links Type (only V 15-18): none - Standard A - SAE A 2 bolts Ma. Displacement (cm 3 /n): 15, 18, 23, 25,
More informationOPERATION AND MAINTENANCE MANUAL
WREN IBT SERIES HYDRAULIC TORQUE WRENCHES IBT SQUARE DRIVE SERIES OPERATION AND MAINTENANCE MANUAL FOR WREN Products: POINT 75, 1IBT, 3IBT, 5IBT, 8IBT, 10IBT, 20IBT, 25IBT, 35IBT, 50IBT SQUARE DRIVE HYDRAULIC
More informationSPEED CONTROLLERS WITH QUICK FITTINGS
SPEED CONTROLLERS WITH QUICK FITTINGS Union Straight Type Fittings for controlling the speed of actuators, such as cylinders. Superior flow rate characteristics and fine tuning adjustments in the low flow
More informationHEAVY DUTY POWER RELAYS FEATURES
VDE VC HEAVY DUTY POWER RELAYS VC RELAYS Faston terminal Screw terminal mm 9 FEATURES VC power relays are designed for controlling heavy duty loads safely: Contact gap of 3 mm or more -point contacts for
More information3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot
3 Port Solenoid Valve Pilot Operated Poppet Type Series VG342 Rubber Seal [Option] Low power consumption 4.8 W DC (Standard type) 2 W DC (Energy-saving type) No lubrication required Possible to use in
More informationExhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000)
5 Port Pilot Operated Solenoid Valve Rubber Seal Series 1000/3000/5000 Large flow capacity Yet compact size. Low power consumption 1.8 W (DC) Exhausting equipment for pilot valve not required. Common exhaust
More informationINSTALLATION, OPERATION, AND MAINTENANCE MANUAL
INSTALLATION, OPERATION, AND MAINTENANCE MANUAL MODEL 4D-200 REDUCED PRESSURE PRINCIPLE (RPZ) & MODEL 4D-700 REDUCED PRESSURE DETECTOR ASSEMBLY (RPDA) BACKFLOW PREVENTERS 2 ½ 10 Conbraco Industries Inc.
More information3 Port Solenoid Valve Direct Operated Poppet Type. Body type. Body ported. Manifold. Valve option
Port Solenoid Valve Direct Operated Poppet ype Series V17 Rubber Seal [Option] Compact yet provides a large flow capacity Dimensions (W x H x D) 45 x 89.5 x 45 (Grommet) C:.6 dm /(s bar) (Passage ) Suitable
More informationSeries VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L
Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body
More informationSeries VQ Port Solenoid Valve
Port Solenoid Valve Series VQ00 Outstandingly high speed, stable response, and long service life. ON:. ms, OFF: ms, Dispension accuracy ms (; supply pressure 0. MPa) 00 million cycles or more (Factors
More informationCheck Valve AP64 P.149. Vacuum Generator Vacuum Generator Module Vacuum Generator Module AP7 & 70 AP71 AP72. Flow Switch Flow Switch (For high flow)
Check Valve eries Check Valve AP64 P.149 Vacuum Generator Vacuum Generator Vacuum Generator Module Vacuum Generator Module Flow witch Flow witch Flow witch (For high flow) eries AP7 & 7 AP71 AP72 eries
More informationPROPORTIONAL VALVES SERVO VALVES. Maximum operating pressure MPa {kgf/cm 2 } Model [Model No.]
J PROPORTIONAL VALVES SERVO VALVES J Model [Model No.] Solenoid pilot operated proportional relief valve [JRP] Solenoid operated proportional relief valve [JRPL] Type C2 solenoid operated proportional
More informationChapter 10: Valves for Pipe Mounting
Contents Chapter : Valves for Pipe Mounting Series Description Size Body Page DIN / ISO 1/8 1/4 3/8 1/2 3/4 1 1¼ 1½ 2 L-port T-port Pressure valves, manual operation R4V R4R Pressure relief function Pressure
More informationSUPPLY JOINTS CONTENTS
ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS CONTENTS Specifications, Order Codes, Size Table 371 Dimensions 373 NCU Specification Order Codes, Model Table 379
More informationLateral parallel hand Double acting. Operational stroke length: 20, 30, 40mm. 980m/s2
FH0 G G B H2 LB2 N/ S/F Specifications Size Cylinder bore size mm Actuation Working fluid Max. working pressure MPa Min. working pressure MPa Ambient temperature C Port size Operational stroke length mm
More informationPRESSURE REGULATOR BACK PRESSURE TO ATMOSPHERE WITH OUTSIDE SUPPLY
PRESSURE REGULATOR BACK PRESSURE TO ATMOSPHERE WITH OUTSIDE SUPPLY All Rights Reserved. All contents of this publication including illustrations are believed to be reliable. And while efforts have been
More information3 Port Solenoid Valve
Port Solenoid Valve Series VQ00 Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, C 9080-0-Main Office: (0) 88-900-Outside Local rea: (800) 8-900-www.stevenengineering.com Outstandingly
More information25% reduction in volume * PB1013A/Air-operated type without foot
Process Pump (Diaphragm Pump) Series Compact, large capacity diaphragm pump, suitable for transferring and collecting a wide range of fluids Smaller, lighter, lmtop size Pa 5% reduction in volume * 11A/Air-operated
More informationEFC. Electronically Adjustable Proportional Pressure Compensated Flow Control
Engineering & Manufacturing Solutions Specifications: See flow chart for capacity. 3000 psi (207 bar) rating. Weighs 8-1/2 lbs. (3.9 kg). Standard Port size #12SAE (1-1/16 12). 10-Micron Filtration Recommended.
More informationSeries VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option.
Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Body option Body
More information3MA0/3MB0. Small pneumatic valve. 3 port direct acting valve CONTENTS. Space saving Valves are compactly designed with widths of 10 mm
M0/MB0 Small pneumatic valve M Overview The M0 and MB0 Series port valve is a 0 mm wide miniature direct-acting poppet valve compatible with system downsizing. variety of types, including discrete and
More informationWESCO INDUSTRIAL PRODUCTS, INC. Folding Handle Scissors Lift Table. Part Number:
WESCO INDUSTRIAL PRODUCTS, INC Folding Handle Scissors Lift Table : 260201 Note: Operator MUST read and understand these operating instructions before using this Folding Handle Scissors Lift Table. TABLE
More informationTPV Variable Displacement Closed Loop System Axial Piston Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 851 / 0813 / E
HYDRAULIC COMPONENTS HYDROSTATIC TRANSMISSIONS GEARBOXES - ACCESSORIES THE PRODUCTION LINE OF HANSA-TMP Variable Displacement Closed Loop System CONTENTS General Information... Order Code... Manual Control
More information2.3 MEDIUM HEAVY DUTY SERIES
2 2.3 MEDIUM HEAVY DUTY SERIES CONTENTS PPV11 Ordering Code 2.3.1 Medium Heavy Duty Series 2.3.2 Torque limiter settings Technical Information 2.3.3 Specifications 2.3.4 Hydraulic fluids 2.3.5 Viscosity
More informationNDR Series Rotor Pack
efore using the product, please check the DR Series Rotor ack Features Low noise chieves a noise level of no greater than 0 d () and there is no need to worry about hydraulic noise even at factories in
More informationVL (AZ8) Limit Switches
COMPACT SIZE LIMIT SWITCHES Limit Switches A compact and accurate vertical limit switch. Type with a lamp which makes maintenance convenient; either a neon AC powered lamp or an LED DC powered lamp. With
More informationRF Point Level Control with Sensor Monitor
The 681 Point Level Control utilizes DPDT relays to provide switching for peripheral devices (such as pumps) in level applications. A sensor attached to the control acts as an antenna to transmit the process
More informationMC-104CER MC-285CRM-E MC-305CRM-E
MC-104CER MC-285CRM-E MC-305CRM-E MINI-CRAWLER CRANE Electric Motor Driven SERVICE MANUAL CONTENTS 1. OUTER DIMENSIONS...1 1.1 Outer Dimensions of Model MC-104CER...1 1.2 Outer Dimensions of Model MC-285CRM-E...2
More informationEUGEN WOERNER GmbH & Co. KG Postfach 1661 DE Wertheim Am Eichamt 8 DE Wertheim. Pump unit GMZ-E
Pump unit GMZ-E Pump used to supply oil and grease from a barrel directly through a lid-hole or a bunghole. Technical data: Pump with bung-hole Pump with barrel lid Delivery volume per stroke: Pump element
More informationInstruction Manual. BS Series
Instruction Manual BS Series NOTE: Owner/Operator must read and understand this instruction manual before using the lift table. RevB: 02/2009 1 Operation and Service Manual BEFORE OPERATING THE LIFT TABLE,
More informationPrecision Cylinder. MTS Series. ø8, ø12, ø16, ø20, ø25, ø32, ø40 MXH MXS MXQ MXQ MXF MXW MXJ MXP MXY MTS D- -X. Series Variations MTS8
Precision Cylinder Series, ø, ø6, ø, ø, ø, ø MXS Series Variations Model 8 Standard stroke (mm) 7 7 Rod end configuration Cushion Rubber bumper End lock Made to Order Rod Variable stroke/ through-hole
More informationCompact Proportional Solenoid Valve
Compact Proportional Solenoid Valve Series Repeatability: % or less Hysteresis:1% or less Fluid Flow rate control range Note) Series Air, Inert gas to L/min to L/min Note) Varies depending on the model.
More informationPNEUMATIC POWER CYLINDER
High Thrust Air Cylinder PNEUMATIC POWER CYLINDER Generates high thrust of tons or higher from air pressure alone. The special mechanism allows for high speed operation. HIROTAKA MFG. CO.,LTD. Overview
More informationMICRO EJECTORS ME12, ME25, ME60. Specifications. Mass MICRO EJECTORS. Vacuum switches. Micro ejectors. Single and twin solenoid valves.
ME12, ME25, ME60 Specifications Micro ejectors Media Operating pressure range MPa [psi.] Operating temperature range C [ F] Nozzle diameter Note mm [in.] kpa [in.hg] flow rate Note R/min [ft. 3 /min.]
More informationPower Valve: Economy Valve. Standard Specifications. Model VEX55-04
Three functions (pressure regulator, switching valve, and speed controller) are provided by a single valve. The conventional valve combination circuit has been condensed into a single valve. A large capacity
More informationBody width of 10mm, Nl/min (49.08) 2W (Standard) Nl/min (78.52) 4W (U type: Large flow) Vacuum applications possible (up to 100kPa) 3 S.
High speed coil with stable response times ON: 4ms, OFF: 2ms, Dispersion accuracy: ±1ms (With light and surge voltage suppressor at a supply pressure of 0.5MPa, subject to clean, dry air) 4 Port Direct
More informationDiaphragm Valve Type 14 Pneumatic Actuated Type AV
Serial No. H-A015-E-7 Contents (1) Be sure to read the following warranty clauses of our product 1 Diaphragm Valve Type 14 Pneumatic Actuated Type AV (2) General operating instructions 2 (3) General instructions
More informationCompact Direct Operated 2/3 Port Solenoid Valve for Water and Air
Compact Direct Operated / Port Solenoid Valve for Water and Air 0/0/0: Port, 00/00: Port 0/0/0 -port type has been remodeled to new compact and lightweight series. For details about new series, refer to
More informationSeries AV2000/3000/4000/5000
Soft Start-up Valve Series AV/3/4/5 Series introduced! A start-up valve that gradually increases supply pressure during start up and rapidly exhausts system air when the supply air is shut off AC AV AU
More informationFree position locking flat and compact cylinder UFCD Series
Space-saving cylinder ensures safety during work in power failures or accidents. Free position locking flat and compact cylinder UFCD Series Free position locking flat and compact cylinder UFCD Series
More informationMICRO EJECTORS. Micro ejector single unit (without solenoid valve) ME. Micro ejector with solenoid valve DC24V. Block-off plate ME MA-BP
Micro Ejector Order Codes Manifold Order Codes Micro ejector single unit (without solenoid valve) ME Body model nozzle diameter : Maximum flow rate on vacuum side 03 0.3 : 3.0R/min. [0.012in., 0.106ft.
More informationTPV 1000 (Ex 6-18) Variable Displacement Closed Loop System Axial Piston Pump HY-TRANS THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 109 / 1008 / E
HYDRAULIC COMPONENTS HYDROSTATIC TRANSMISSIONS GEARBOXES - ACCESSORIES HY-TRANS THE PRODUCTION LINE OF HANSA-TMP Via M.L. King, 6-41122 MODENA (ITALY) Tel: +39 059 415 711 Fax: +39 059 415 729 / 059 415
More informationMiniature Regulator. Standard Specifications. Model IN side OUT side (Applicable tubing O.D.) Proof pressure Maximum operating pressure
Miniature Regulator Series 00F Compact and lightweight ( g) Low cracking pressure 0.0 MPa Standard model equipped with backflow function Standard Specifications Port size Fluid side side (Applicable tubing
More informationSPECIFICATIONS TEST AND ADJUSTMENT SPECIFICATIONS SPECIFICATIONS ENGINE FD620D, K SERIES
ENGINE FD620D, K SERIES SPECIFICATIONS SPECIFICATIONS TEST AND ADJUSTMENT SPECIFICATIONS Engine Oil Pressure Sensor Activates............................... 98 kpa (14.2 psi) Oil Pressure While Cranking
More informationInstallation. Installation. 12. System Diagram... 10
Pressure Control Systems Installation Instructions Form No. F-1031 Section 3010 Issue Date 08/20/96 Rev. Date 9/11/17 Table of Contents Discharge Relief Valve System System Description....................................
More informationBRAKE E
8-1 GENERAL...8-2 SPECIFICATIONS...8-6 COMPONENTS...8-7 FRONT BRAKE...8-12 DISASSEMBLY INSPECTION REASSEMBLY (Pn1, Cu2 3 TON SERIES)...8-12 DISASSEMBLY INSPECTION REASSEMBLY (Pn2 3 TON SERIES)...8-17 BRAKE
More informationOperation Manual For KITZ B Series Pneumatic Valve Actuators
Operation Manual For KITZ B Series Pneumatic Valve Actuators Thank you for choosing KITZ products. For safe and trouble-free function and performance of the product, ensure to read and understand all items
More informationVL (AZ8) Limit Switches
COMPACT SIZE LIMIT SWITCHES VL (AZ8) Limit Switches A compact and accurate vertical limit switch. Switches with indicator lamp available for convenient maintenance; either a neon AC powered lamp or an
More informationHYDRAULIC VARIABLE PUMPS
HYDRAULIC VARIABLE S EFFICIENT VARIABLE DELIVERY Checkball pump delivery is controlled by variable inlet ports in each piston pumping chamber. In these hydraulic variable models, output is regulated by
More informationInternet For latest information, PDF catalogs and operation manuals
DJ Series ew DIPK omenclature Features DJ - - 0-4 6 7 Low noise The tank contains the pump and motor inside and functions itself as noise insulation panels to trap noise internally. Low oil temperature
More informationIN-LINE HYDRAULIC FLOW TESTER
SPX Corporation 5885 11th Street Rockford, IL 61109-3699 USA Internet Address: http://www.powerteam.com Tech. Services: (800) 477-8326 Fax: (800) 765-8326 Order Entry: (800) 541-1418 Fax: (800) 288-7031
More informationPneumatic Drive Type Drill Bit Breakage Detection Sensor. DFM3 Series. The World's First!! Pneumatic-Drive Type. Catalog / Instruction Manual US.PAT.
Pneumatic Drive Type Drill Bit Breakage Detection Sensor DFM3 Series The World's First!! Pneumatic-Drive Type Catalog / Instruction Manual US.PAT. Pneumatic Drive Type Drill Bit Breakage Detection Sensors
More informationHYDROMODEL-200. Implements and controls hydraulic and electro-hydraulic circuits. Transparent Hydraulics - Electro-hydraulics
HYDROMODEL-200 Transparent Hydraulics - Electro-hydraulics Hydraulic and electro-hydraulic technology at a glance Implements and controls hydraulic and electro-hydraulic circuits www.smctraining.com training@smctraining.com
More information5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve
5.0 MPa Pilot Operated / Port Solenoid Valve & Check Valve Series VCH VCH4/4: Port VCH40: Port VCHC40: Check Valve Pilot Operated Port Solenoid Valve Series VCH40 Stable responsiveness Response time dispersion
More informationFLOW CONTROL VALVES A5-1 PN# / / ACC
FLOW CONTROL VLVES Flow Control Valves The HYDC family of flow control valves permit safe, simple and repeatable control of hydraulic fluids at operating pressures to psi. The standard slotted control
More informationRotary Damper Pneumatic Actuated Type TA
Serial No. H-A030-E-4 Rotary Damper Pneumatic Actuated Type TA Contents (1) Be sure to read the following warranty clauses of our product 1 (2) General operating instructions 2 (3) General instructions
More informationWESCO INDUSTRIAL PRODUCTS, INC. Heavy Duty Scissors Lift Tables. Part Number: &
WESCO INDUSTRIAL PRODUCTS, INC Part Number: 272970 & 272973 Note: Operator MUST read and understand these operating instructions before using this Heavy Duty Scissors Lift Table. TABLE OF CONTENTS 1 General
More informationSPECIFICATIONS TEST AND ADJUSTMENT SPECIFICATIONS SPECIFICATIONS ENGINE FD620D, K SERIES
TEST AND ADJUSTMENT Engine Oil Pressure Sensor Activates............................... 98 kpa (14.2 psi) Oil Pressure While Cranking (Minimum).......................... 28 kpa (4 psi) Oil Pressure.....................................
More informationUnder Axle Jack Max. Capacity: 25 Tons
SPX Corporation 655 Eisenhower Drive Owatonna, MN 55060-0995 USA Phone: (507) 455-7000 Tech. Serv.: (800) 533-6127 Fax: (800) 955-8329 Order Entry: (800) 533-6127 Fax: (800) 283-8665 International Sales:
More informationPneumatic Cylinder. 3I Double-acting type. 3Q Single-acting type (spring returned type)
Pneumatic Cylinder State of the art in actuation, Tomoe cylinders offer compactness, lighter weight, and higher output torque. I Double-acting type Q Single-acting type (spring returned type) Features
More informationHydrostatic Power Train
Chapter Hydrostatic Power Train Specifications................................................................. -3 Test Specifications........................................................ -3 Repair
More informationSVR10 SVA10. External Pilot air specification. Conventional specification 0 ~ 0.7. Compact, yet keeps large capacity.» Limited space can be utilized.
Compact, yet keeps large capacity.» Limited space can be utilized. Standard.» SVR 10 series takes over the functions (Valve variations) of discontinued SVA 10 series. Pneumatic Symbols 1(P) 1(P) 1(P) 1(P)
More information2. Hydraulic Valves, Actuators and Accessories. 24 Marks
2. Hydraulic Valves, Actuators and Accessories 24 Marks Co related to chapter 602.2 Describe working principle of various components used in hydraulic & pneumatic systems. 602.3 Choose valves, actuators
More informationSoft Start-up Valve. AV2000/3000/4000/5000 Series
Soft Start-up Valve V000/000/000/000 Series [Option] C- R- W- C R - W - Start-up valve for low speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off
More informationSeries 7000 Torque Sensor for PTO-shafts
Properties PTO (Power Take-Off) shaft with integrated torque and angle measurement Non-contact measurement system, high robustness Special for PTO shafts 1 ¾ und 1 3/8 Plug & Play solution, no additional
More informationSERIES OPERATION AND MAINTENANCE MANUAL
SERIES OPERATION AND MAINTENANCE MANUAL This manual CONTAINS IMPORTANT WARNINGS, S and OTHER INSTRUCTIONS. Read and understand the instruction manual Carefully, before use and retain it for reference.
More informationPARTS & ASSEMBLY DRAWINGS SECTION 1. Jacket
000SVRM-3 /7 CONTROL VALVE PARTS & ASSEMBLY DRAWINGS SECTION Base Valve O-ring O-ring Sleeve Cage/Barrier Assembly Spacer Jacket Description 2 Valve 3 Valve Base Valve, 0-40 psi 2255-000 2239-0090 Base
More information114 NOSE SEIKO CO.,LTD NOSE SEIKO CO.,LTD
114 NOSE SEIKO CO.,LTD NOSE SEIKO CO.,LTD 115 and Part Code Applicable axis diameter Feature Part Code 5 ~ 3 General purpose cam follower with screwdriver groove on the stud head. Available with stainless
More informationInternet For latest information, PDF catalogs and operation manuals
EcoRich Features Achieves a % or greater energy saving (in the pressure retained mode, comparison with Daikin products) Drastic energy savings are realized by reducing the motor rotation speed in pressure
More informationStandard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve
Mist Spray Unit Series MU/ Intermittent spray to cutting and press gear chains, etc. Standard Specifications MU MU Inlet air Oil tank set range. MPa. to. MPa Oil tank capacity (cm ) Total capacity: Effective
More information5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)
For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Model 2 position 3 position
More informationElectro-pneumatic Proportional Valve. Specifications. Model Flow type Pressure type VEF2121
Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 6-580 www.cmafh.com VEF Port Port Applicable power Body size Body size Electro-pneumatic Proportional
More informationHydraulics. Part B, Section 1. This section covers the following unit configurations. 3700V 3800V 3900V
Part B, Section 1 Model Voltage Pump Manifold Control This section covers the following unit configurations. 3500V 3700V 3800V 3900V All Piston (F) 4-Port (A) 6-Port (B or C) -Port (S or T) Vista Standard
More informationVacuum / Release Unit
Rubber Seal Vacuum / Release Unit Series VQD1000-V Response speed 13 msec (at 500 mm )/18.5 msec (at 1000 mm ) Distance from the unit to the work area Smooth detachment of a work piece without over-blow
More information5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve
5.0 MPa Pilot Operated /3 Port Solenoid Valve & Check Valve VCH Series VCH4/4: Port VCH40: 3 Port VCHC40: Check Valve Pilot Operated Port Solenoid Valve [Option] VCH40 Series Stable responsiveness Response
More informationService Jack. Form No Parts List & Operating Instructions 1510B. Max. Capacity: 5 and 10 Tons. 1 of 3. Sheet No. Issue Date: Rev.
SPX Corporation 655 Eisenhower Drive Owatonna, MN 55060-0995 USA Phone: (507) 455-7000 Tech. Serv.: (800) 533-6127 Fax: (800) 955-8329 Order Entry: (800) 533-6127 Fax: (800) 283-8665 International Sales:
More informationSeries 7000 Torque Sensor for PTO-shafts
Properties PTO (Power Take-Off) shaft with integrated torque and angle measurement Non-contact measurement system, high robustness Special for PTO shafts 1 ¾ und 1 3/8 Plug & Play solution, no additional
More information91 \\SERVER\CATALOG 2018\2018 Catalog Rev 1 SHUT OFF BALL VALVE
SHUT OFF BALL VALVE Maxton Elevator Shut Off Valves are specifically built for hydraulic elevators and are labeled and tested to comply with ASME A17.1 / CSA B44 at a 5:1 Safety factor. BV2G2G SHOWN Hard
More informationCH.4 Basic Components of Hydraulic and Pneumatic System/16 M HAP/17522/AE5G
Content : 4.1 Hydraulic and Pneumatic actuators. 10 Marks Hydraulic Actuators - Hydraulic cylinders (single, double acting and telescopic) construction and working, Hydraulic motors (gear and piston type)
More informationHeavy Duty Hydrostatic Transmissions
Heavy Duty Hydrostatic Transmissions Features and Benefits Typical Applications Construction Transit Mixer Road Roller Paver Motor Grader Loader Dozer Material Handling & Utility Crane Sweeper Lift Truck
More informationTroubleshooting the Transmission Hydraulic System
Testing and Adjusting IT28F INTEGRATED TOOLCARRIER POWER TRAIN Testing And Adjusting Introduction Reference: For Specifications with illustrations, refer to SENR5974, IT28F Integrated Toolcarrier Power
More informationINSTALLATION AND MAINTENANCE OF TOP LOADING ARM
INSTALLATION AND MAINTENANCE OF TOP LOADING ARM D TABLE OF CONTENTS 1. INTRODUCTION 04 2. SPECIFICATION OF THE REDLANDS LOADING ARM 04 3. INSTALLING THE LOADING ARM 3.1. Installation Procedures 05 4.
More informationCompact Flow Rate Sensor. RAPIFLOW FSM3 Series Resin Body Type. Diversified High Performance. High performance. User-friendly. Compatible CC-1235A 1
Compact Flow Rate Sensor RAPIFLOW Resin Body Type Diversified High Performance High performance User-friendly Compatible CC-1235A 1 Diversified Five types of gases can be measured with just one unit Gas
More informationNDJ Series New DAIPACK
DJ Series ew DIPK omenclature DJ - - 0-4 6 7 Model o. DJ: ew DIPK Pump capacity 8: V 8 used ( 8 cm /rev) : V used (4.8 cm /rev) Pressure adjustment range 9: 0.8 to. MPa {8 to kgf/cm } : 0.8 to 7 MPa {8
More informationVacuum applications possible (up to 100kPa) Base mounted. Cylinder bore size (mm) Series CM2. Pressure: 0.5MPa Load ratio: 50% Cylinder stroke: 300mm
4 Port Direct Operated Poppet Solenoid Valve Series D1000 High speed coil with stable response times ON: 4ms, OFF: 2ms, Dispersion accuracy: ±1ms (With light and surge voltage suppressor at a supply pressure
More informationCateye Ergometer. Belt Drive, Automatic Type. Service Manual. Model EC-1200/EC-1600/EC-3600/EC-3700/EC-C400/EC-C400R Ver.
Cateye Ergometer Belt Drive, Automatic Type Model ///// Service Manual 9.1.2002 Ver.01 INDEX INTRODUCTION How to Use This Service Manual Name of Parts 1. Upright Type (w/o Flywheel) ---------------------------------------------------------
More informationIdeal Installation. I & M Mark 67 (1/2 6 ) Control Line. Installation & Maintenance Instructions for Mark 67 Pressure Regulators
I & M Mark (/ ) 0 Wasson Road Cincinnati, OH 0 USA Phone --00 Fax -8-00 info@richardsind.com www.jordanvalve.com Installation & Maintenance Instructions for Mark Pressure Regulators Warning: Jordan Valve
More informationOperation and Maintenance Manual http://www.torsionx.eu Use the MaxDrv Series Square Drive Torque Wrench Model.75, 1, 3, 5, 8, 10, 20, 25, 35, 50 to install and remove threaded fasteners requiring precise
More information3 Port Direct Operated Poppet Rubber Seal. Standard Continuous duty Energy saving Vacuum Energy saving/vacuum
3 Port Direct Operated Poppet Rubber Seal Series 307 Large Flow Capacity, yet Compact Size. Dimensions (W X H X D) 30 X 54.5 X 33 307 Nl/min 206.02 or more, 1/4 Low Power Consumption /VO307 4.8W DC/Standard
More information