1.56" (39.5 mm) 0.20" (5.1 mm) Specifications terminal block Certifications CSA IEC CSA IEC CSA IEC 500V AC/DC 300V AC/DC AC/DC

Size: px
Start display at page:

Download "1.56" (39.5 mm) 0.20" (5.1 mm) Specifications terminal block Certifications CSA IEC CSA IEC CSA IEC 500V AC/DC 300V AC/DC AC/DC"

Transcription

1 Bulletin Screw Connection Terminal Blocks Plug-In Style Terminal Blocks Dimensions are not intended to be used for manufacturing purposes. Note: Height dimension is measured from top of rail to top of terminal block.." (. mm) -JP -JPTP -JDP." (. mm)." (. mm)." (. mm)." (. mm)." ( mm)." ( mm)." (. mm) Selectable component plug-in Selectable component plug-in Two Circuit selectable component terminal block terminal block with test plug socket plug-in terminal block Certifications CSA IEC CSA IEC CSA IEC Voltage Rating V V V V V." (. mm) V V Maximum Current A A A A A A A A # # Wire Range (Rated Cross Section) #. mm #. mm. mm Wire Strip Length. in. ( mm). in. ( mm). in. ( mm) Recommended Tightening Torque. lb in (. N m). lb in (. N m). lb in (. N m) Density pcs/ft ( pcs/m) pcs/ft ( pcs/m) pcs/ft ( pcs/m) Housing Temperature Range - + F (- + C) - + F (- + C) - + F (- + C) Short-Circuit Current Rating See page - Terminal Blocks Pkg Qty. Pkg Qty. Pkg Qty. Color: Grey -JP -JPTP -JDP Red -JP-RE Accessories Pkg Qty. Pkg Qty. Pkg Qty. Mounting Rails: m Symmetrical DIN (Steel) -DR -DR -DR m Symmetrical DIN (Aluminum) -DR -DR -DR m Hi-Rise Sym. DIN (Aluminum) -DR -DR -DR m Angled Hi-Rise Sym. DIN (Steel) -DR -DR -DR End Barriers -EBJ -EBJ -EBJDP End Anchors and Retainers: -ERL -ERL -ERL DIN Rail Normal Duty -EAJ -EAJ -EAJ DIN Rail Heavy Duty -EAHJ -EAHJ -EAHJ Jumpers : Center Jumper -Pole -CJLJ- -CJLJ- Center Jumper -Pole -CJLJ- -CJLJ- -CJJ- Center Jumper -Pole -CJLJ- -CJLJ- Center Jumper -Pole -CJLJ- -CJLJ- Center Jumper -Pole -CJLJ- -CJLJ- Center Jumper -Pole -CJLJ- -CJLJ- Center Jumper -Pole -CJLJ- -CJLJ- Center Jumper -Pole -CJLJ- -CJLJ- -CJJ- Center Jumper -Pole -CJLJ- -CJLJ- -CJJ- Center Jumper -Pole -CJLJ- -CJLJ- -CJJ- Screw Type Jumper Notching Tool -T Other Accessories: Partition Plate -EBJ -EBJ -PPJDP Test Plug -TP Disconnect Plug -DPL -DPL -DPL Component Plug -CPL -CPL -CPL Fuse Plug Without Blown Fuse Indicator -FPK -FPK -FPK V Blown Fuse Indicator -FPK -FPK -FPK V Blown Fuse Indicator -FPK -FPK -FPK V Blown Fuse Indicator -FPK -FPK -FPK V Blown Fuse Indicator -FPK -FPK -FPK Marking Systems: Snap-in marker cards -MX (/card) -MX (/card) -SMX (/card) Snap-in marker cards -MX (/card) -MX (/card) -MX (/card) Cat. nos. -JP and JPTP use screwless center jumpers. -JDP uses a screw-type center jumper. Use of Center Jumpers may affect spacings, requiring derating of terminal blocks. See the Terminal Block selection guide, pub. no. -SG*. - Publication A-CAA-EN-P

2 Bulletin Screw Connection Terminal Blocks Plug-In Style Terminal Blocks Dimensions are not intended to be used for manufacturing purposes. Note: Height dimension is measured from top of rail to top of terminal block.." (. mm) -JDPTP -JDPSS -JDPSSTP." (. mm)." (. mm)." (. mm)." (. mm)." (. mm) Two-circuit selectable component Two-circuit selectable component Two-circuit selectable component plug-in terminal block with test plug plug-in terminal block with internal plug-in terminal block with internal socket surge suppressor surge suppressor and test plug socket Certifications CSA IEC CSA IEC CSA IEC Voltage Rating V V." (. mm)." (. mm) V V AC V." (. mm) V Maximum Current A A A A A A Wire Range (Rated Cross Section) # # # # # #. mm. mm. mm Wire Strip Length. in. ( mm). in. ( mm). in. ( mm) Recommended Tightening Torque. lb in (. N m). lb in (. N m). lb in (. N m) Density pcs/ft ( pcs/m) pcs/ft ( pcs/m) pcs/ft ( pcs/m) Housing Temperature Range - + F (- + C) - + F (- + C) + F ( + C) Short-Circuit Current Rating See page - Terminal Blocks Pkg Qty. Pkg Qty. Pkg Qty. Color: Grey -JDPTP -JDPSS -JDPSSTP Accessories Pkg Qty. Pkg Qty. Pkg Qty. Mounting Rails: m Symmetrical DIN (Steel) -DR -DR -DR m Symmetrical DIN (Aluminum) -DR -DR -DR m Hi-Rise Sym. DIN (Aluminum) -DR -DR -DR m Angled Hi-Rise Sym. DIN (Steel) -DR -DR -DR End Barriers -EBJDP -EBJDP -EBJDP End Anchors and Retainers: -ERL -ERL -ERL DIN Rail Normal Duty -EAJ -EAJ -EAJ DIN Rail Heavy Duty -EAHJ -EAHJ -EAHJ Jumpers: Screw Center Jumper -Pole -CJJ- -CJJ- -CJJ- Screw Center Jumper -Pole -CJJ- -CJJ- -CJJ- Screw Center Jumper -Pole -CJJ- -CJJ- -CJJ- Screw Center Jumper -Pole -CJJ- -CJJ- -CJJ- Screw Type Jumper Notching Tool -T -T -T Other Accessories: Partition Plate -PPJDP -PPJDP -PPJDP Test Plug -TP -TP Disconnect Plug -DPL -DPL -DPL Component Plug -CPL -CPL -CPL Fuse Plug Without Blown Fuse Indicator -FPK -FPK -FPK V Blown Fuse Indicator -FPK -FPK -FPK V Blown Fuse Indicator -FPK -FPK -FPK V Blown Fuse Indicator -FPK -FPK -FPK V Blown Fuse Indicator -FPK -FPK -FPK Group Marking Carrier -GM -GM -GM Marking Systems: Snap-in marker cards -SMX (/card) -SMX (/card) -SMX (/card) Snap-in marker cards -MX (/card) -MX (/card) -MX (/card) Publication A-CAA-EN-P -

3 Bulletin Screw Connection Terminal Blocks Double-Level Plug-In Style Terminal Blocks Dimensions are not intended to be used for manufacturing purposes. Note: Height dimension is measured from top of rail to top of terminal block.." (. mm) -JDGP -JDGPTP -JDGPSS." (. mm)." (. mm)." (. mm)." (. mm)." (. mm) Two-circuit block with ground Two-circuit block with test plug socket Single-circuit block with MOV to connection and ground connection ground Certifications CSA IEC CSA IEC CSA IEC Voltage Rating V V." (. mm) V V." (. mm) V." (. mm) V AC Maximum Current A A A A A A Wire Range (Rated Cross Section) # # # # # #. mm. mm. mm Wire Strip Length. in. ( mm). in. ( mm). in. ( mm) Recommended Tightening Torque. lb in (. N m). lb in (. N m). lb in (. N m) Density pcs/ft ( pcs/m) pcs/ft ( pcs/m) pcs/ft ( pcs/m) Housing Temperature Range - + F (- + C) - + F (- + C) - + F (- + C) Short-Circuit Current Rating See page - Terminal Blocks Pkg Qty. Pkg Qty. Pkg Qty. Color: Grey -JDGP -JDGPTP -JDGPSS Accessories Pkg Qty. Pkg Qty. Pkg Qty. Mounting Rails: m Symmetrical DIN (Steel) -DR -DR -DR m Symmetrical DIN (Aluminum) -DR -DR -DR m Hi-Rise Sym. DIN (Aluminum) -DR -DR -DR m Angled Hi-Rise Sym. DIN (Steel) -DR -DR -DR End Barriers -EBJDP -EBJDP -EBJDP End Anchors and Retainers: -ERL -ERL -ERL DIN Rail Normal Duty -EAJ -EAJ -EAJ DIN Rail Heavy Duty -EAHJ -EAHJ -EAHJ Jumpers: Screw Center Jumper -Pole -CJJ- -CJJ- Screw Center Jumper -Pole -CJJ- -CJJ- Screw Center Jumper -Pole -CJJ- -CJJ- Screw Center Jumper -Pole -CJJ- -CJJ- Screw Type Jumper Notching Tool -T -T Other Accessories: Partition Plate -PPJDP -PPJDP -PPJDP Test Plug -TP Disconnect Plug -DPL -DPL -DPL Component Plug -CPL -CPL -CPL Fuse Plug Without Blown Fuse Indicator -FPK -FPK -FPK V Blown Fuse Indicator -FPK -FPK -FPK V Blown Fuse Indicator -FPK -FPK -FPK V Blown Fuse Indicator -FPK -FPK -FPK V Blown Fuse Indicator -FPK -FPK -FPK Marking Systems: Snap-in marker cards -SMX (/card) -SMX (/card) -SMX (/card) Snap-in marker cards -MX (/card) -MX (/card) -MX (/card) - Publication A-CAA-EN-P

4 Bulletin Screw Connection Terminal Blocks Double-Level Plug-In Style Terminal Blocks Dimensions are not intended to be used for manufacturing purposes. Note: Height dimension is measured from top of rail to top of terminal block. -JDGPSSTP." (. mm)." (. mm) Single-circuit block with MOV to ground and test plug socket Certifications CSA IEC Voltage Rating V V AC Maximum Current A A Wire Range (Rated Cross Section) # #. mm Wire Strip Length. in. ( mm) Recommended Tightening Torque. lb in (. N m) Density pcs/ft ( pcs/m) Housing Temperature Range - + F (- + C) Short-Circuit Current Rating See page - Terminal Blocks Pkg Qty. Color: Grey -JDGPSSTP Accessories Pkg Qty. Mounting Rails: m Symmetrical DIN (Steel) -DR m Symmetrical DIN (Aluminum) -DR m Hi-Rise Sym. DIN (Aluminum) -DR m Angled Hi-Rise Sym. DIN (Steel) -DR End Barriers -EBJDP End Anchors and Retainers: -ERL DIN Rail Normal Duty -EAJ DIN Rail Heavy Duty -EAHJ Other Accessories: Partition Plate -PPJDP Test Plug -TP Disconnect Plug -DPL Component Plug -CPL Fuse Plug Without Blown Fuse Indicator -FPK V Blown Fuse Indicator -FPK V Blown Fuse Indicator -FPK V Blown Fuse Indicator -FPK V Blown Fuse Indicator -FPK Marking Systems: Snap-in marker cards -SMX (/card) Snap-in marker cards -MX (/card)." (. mm) Publication A-CAA-EN-P -

5 Bulletin Screw Connection Terminal Blocks Internal Component Blocks Dimensions are not intended to be used for manufacturing purposes. Note: Height dimension is measured from top of rail to top of terminal block.." (. mm) -JDF -JDDF -JDDR." ( mm)." (. mm)." (. mm)." (. mm)." (. mm)." (. mm)." ( mm)." ( mm) Single-level diode forward terminal Two-Level terminal block with a diode Two-Level terminal block with a diode block with test plug sockets in forward bias between the levels. in reverse bias between the levels. Certifications CSA IEC CSA IEC CSA IEC Voltage Rating V V V V V V V Diode Reverse Voltage Rating V V Maximum Current A A A A A A A Diode Current A A Resistor Type Resistor Value Current through Busbar A A A A A Wire Range (Rated Cross Section) #.. mm # #. mm # # Wire Strip Length. in. ( mm). in. ( mm). in. ( mm) Recommended Tightening Torque.. lb in (.. N m).. lb in (.. N m).. lb in (.. N m) Density pcs/ft ( pcs/m) pcs/ft ( pcs/m) pcs/ft ( pcs/m) Housing Temperature Range - + F (- + C) - + F (- + C) - + F (- + C) Short-Circuit Current Rating See [T-] V. mm Terminal Blocks Pkg Qty. Pkg Qty. Pkg Qty. Color: Black -JDF -JDDF -JDDR Accessories Pkg Qty. Pkg Qty. Pkg Qty. Mounting Rails: m Symmetrical DIN (Steel) -DR -DR -DR m Symmetrical DIN (Aluminum) -DR -DR -DR m Hi-Rise Sym. DIN (Aluminum) -DR -DR -DR m Angled Hi-Rise Sym. DIN (Steel) -DR -DR -DR End Barrier -EBJ -EBJD -EBJD End Anchors: -ERL -ERL -ERL DIN Rail Normal Duty -EAJ -EAJ -EAJ DIN Rail Heavy Duty -EAHJ -EAHJ -EAHJ Jumpers: Screw Center Jumper -pole -CJJ- -CJJ- Screw Center Jumper -pole -CJJ- -CJJ- Screw Center Jumper -pole -CJJ- -CJJ- Screw Center Jumper -pole -CJJ- -CJJ- Insulated Side Jumper -Pole -SJA- -SJA- Insulated Side Jumper -Pole -SJA- -SJA- Screw Type Jumper Notching Tool -T -T Other Accessories: Partition Plate -SPJ -PPJD -PPJD Other Accessories: Test Plug -TP Marking Systems: Snap-in marker card -MRX (/card) -MX (/card) -MX (/card) Snap-in marker card -MX (/card) -MX (/card) -MX (/card) See page - for component specifications. - Publication A-CAA-EN-P

6 Bulletin Screw Connection Terminal Blocks Internal Component Blocks -JDRC Dimensions are not intended to be used for manufacturing purposes. Note: Height dimension is measured from top of rail to top of terminal block.." (. mm)." (. mm)." (. mm) -JDSS." (. mm)." ( mm)." ( mm) Two-level terminal block with a ohm resistor between the levels Two-level terminal block with an MOV between the levels. Certifications CSA IEC CSA IEC Voltage Rating V V V V V Resistor Type Precision Wire Wound Resistor Value Ω, / W Current through Busbar A A A A A Wire Range (Rated Cross Section) # #. mm # #. mm Wire Strip Length. in. ( mm). in. ( mm) Recommended Tightening Torque.. lb in (.. N m).. lb in (.. N m) Density pcs/ft ( pcs/m) pcs/ft ( pcs/m) Housing Temperature Range - + F (- + C) - + F (- + C) Terminal Blocks Pkg Qty. Pkg Qty. Color: Grey -JDRC -JDSS Accessories Pkg Qty. Pkg Qty. Mounting Rails: m Symmetrical DIN (Steel) -DR -DR m Symmetrical DIN (Aluminum) -DR -DR m Hi-Rise Sym. DIN (Aluminum) -DR -DR m Angled Hi-Rise Sym. DIN (Steel) -DR -DR End Barrier -EBJD -EBJD End Anchors: -ERL -ERL DIN Rail Normal Duty -EAJ -EAJ DIN Rail Heavy Duty -EAHJ -EAHJ Jumpers: Screw Center Jumper -pole -CJJ- -CJJ- Screw Center Jumper -pole -CJJ- -CJJ- Screw Center Jumper -pole -CJJ- -CJJ- Screw Center Jumper -pole -CJJ- -CJJ- Insulated Side Jumper -Pole -SJA- -SJA- Insulated Side Jumper -Pole -SJA- -SJA- Screw Type Jumper Notching Tool -T -T Other Accessories: Partition Plate -PPJD -PPJD Marking Systems: Snap-in marker card -MX (/card) -MX (/card) Snap-in marker card -MX (/card) -MX (/card) See page - for component specifications. Publication A-CAA-EN-P -

7 Bulletin Screw Connection Terminal Blocks Thermocouple Blocks Dimensions are not intended to be used for manufacturing purposes. Note: Height dimension is measured from top of rail to top of terminal block. -JTC." (. mm)." ( mm) Two circuit terminal block with current bars made of thermocouple material Certifications IEC ATEX Voltage Rating V Wire Range (Rated Cross Section) # #.... mm. mm Wire Strip Length. in. ( mm) Recommended Tightening Torque.. lb in (.. N m) Density pcs/ft ( pcs/m) Housing Temperature Range - + F (- + C) Short-Circuit Current Rating See page - Terminal Blocks Pkg Qty. Color/Type/Material Gray/Type B/ S-Copper, E-Copper -JTCB Gray/Type E/ Chromel, Constantan -JTCE Gray/Type J/ Iron, Constantan -JTCJ Gray/Type K/ Chromel, Alumel -JTCK Gray/Type N/ Ni-Cr-Si, Ni-Si-Mg -JTCN Gray/Type S/ E-Copper, A-Copper -JTCS Gray/Type T/ E-Copper, Constantan -JTCT Accessories Pkg Qty. Mounting Rails: m Symmetrical DIN (Steel) -DR m Symmetrical DIN (Aluminum) -DR m Hi-Rise Sym. DIN (Aluminum) -DR m Angled Hi-Rise Sym. DIN (Steel) -DR End Barrier -EBJ End Anchors and Retainers: -ERL DIN Rail Normal Duty -EAJ DIN Rail Heavy Duty -EAHJ Other Accessories: Partition Plate -EBJ Marking Systems: Snap-in marker cards -MX (/card) Individual Marker Tabs (Single Char.) -MX (/card)." ( mm) - Publication A-CAA-EN-P

8 Bulletin Screw Connection Terminal Blocks Neutral Disconnect & Installation Blocks Dimensions are not intended to be used for manufacturing purposes. Note: Height dimension is measured from top of rail to top of terminal block.. (. mm) -JDGND -JDN -JDGN. ( mm). (. mm) -Level terminal block with neutral disconnect and ground connection. (. mm). ( mm). (. mm) -Level feed-through terminal block for installation applications. (. mm). ( mm). (. mm) -Level terminal block with feedthrough and ground connection Certifications CSA IEC CSA IEC CSA IEC Voltage Rating V V V V V V Maximum Current A A A A A A A A A Wire Range (Rated Cross Section) # #. mm # #. mm # # Wire Strip Length. in. ( mm). in. ( mm). in. ( mm) Recommended Tightening Torque. lb in (. N m). lb in (. N m). lb in (. N m) Density pcs/ft ( pcs/m) pcs/ft ( pcs/m) pcs/ft ( pcs/m) Housing Temperature Range F (-...+ C) F (-...+ C) F (-...+ C) Short-Circuit Current Rating See page -. mm Terminal Blocks Pkg Qty. Pkg Qty. Pkg Qty. Color: Grey -JDGND -JDN -JDGN Accessories Pkg Qty. Pkg Qty. Pkg Qty. Mounting Rails: m Symmetrical DIN (Steel) -DR -DR -DR m Symmetrical DIN (Aluminum) -DR -DR -DR m Hi-Rise Sym. DIN (Aluminum) -DR -DR -DR m Angled Hi-Rise Sym. DIN (Steel) -DR -DR -DR End Barriers Grey -BSPJLDN -BSPJLDN -BSPJLDN Busbar Support Blue -BSPJLDN-B -BSPJLDN-B -BSPJLDN-B Plates End Anchors and Retainers: -ERL -ERL -ERL End Anchor Normal Duty -EAJ -EAJ -EAJ End Anchor Heavy Duty -EAHJ -EAHJ -EAHJ Jumpers: Screw Center Jumper -pole -CJJN- -CJJN- -CJJN- Screw Center Jumper -pole -CJJN- -CJJN- -CJJN- Screw Center Jumper -pole -CJJN- -CJJN- -CJJN- Screw Center Jumper -pole -CJJN- -CJJN- -CJJN- Other Accessories: Test Plug Socket -TPS -TPS -TPS Test Plug -TP -TP -TP Neutral Connection Block ( mm) Blue -JNC-B Neutral Bus Bar ( m) -NBB-M Marking Systems: Snap-in Marker Cards -MX (/card) -MX (/card) -MX (/card) These terminals mount on the -NBB-M Netural Busbar. They can accept -MX snap-in markers. Preferred availability cat. nos. are bold. Publication A-CAA-EN-P -

9 Bulletin Screw Connection Terminal Blocks Single-Circuit Neutral Disconnect Blocks Dimensions are not intended to be used for manufacturing purposes. Note: Height dimension is measured from top of rail to top of terminal block.. ( mm) -JND -JND -JND. ( mm). (. mm). ( mm). ( mm). (. mm). ( mm). ( mm). ( mm) Single-level screw neutral disconnect terminal block Single-level screw neutral disconnect terminal block Single-level screw neutral disconnect terminal block Certifications CSA IEC CSA IEC CSA IEC Voltage Rating V V V V V V Maximum Current A A A A A A A A Wire Range (Rated Cross Section) # #. mm # # mm # mm Wire Strip Length. in. ( mm). in. ( mm). in. ( mm) Recommended Tightening Torque. lb in (. N m). lb in (. N m). lb in (. N m) Density pcs/ft ( pcs/m) pcs/f (/ pcs/m) pcs/ft ( pcs/m) Housing Temperature Range F (-...+ C) F (-...+ C) F (-...+ C) Short-Circuit Current Rating See page - Terminal Blocks Pkg Qty. Pkg Qty. Pkg Qty. Color: Blue -JND -JND -JND Accessories Pkg Qty. Pkg Qty. Pkg Qty. Mounting Rails: m Symmetrical DIN (Steel) -DR -DR -DR m Symmetrical DIN (Aluminum) -DR -DR -DR m Hi-Rise Sym. DIN (Aluminum) -DR -DR -DR m Angled Hi-Rise Sym. DIN (Steel) -DR -DR -DR End Barriers Busbar Support Blue -BSPJND-B -BSPJND-B -BSPJND-B Plates End Anchors and Retainers: -ERL -ERL -ERL End Anchor Normal Duty -EAJ -EAJ -EAJ End Anchor Heavy Duty -EAHJ -EAHJ -EAHJ Neutral Connection Block ( mm) Blue -JNC-B -JNC-B -JNC-B Neutral Bus Bar ( m) -NBB-M -NBB-M -NBB-M Marking Systems: Snap-in Marker Cards -MRX (/card) -MRX (/card) -MRX (/card) -MX (/card) -MX (/card) -MX (/card) These terminals mount on the -NBB-M Netural Busbar. They can accept -MX snap-in markers. - Publication A-CAA-EN-P

10 -H... Bulletin Screw Connection Terminal Blocks -WFB Fuse Blocks Dimensions are not intended to be used for manufacturing purposes. Note: Height dimension is measured from top of rail to top of terminal block.." ( mm)." (. mm)." (. mm)." (. mm) Single-circuit fusible terminal block with or without fuse indication. Single-circuit fuse block with or without fuse indication. Certifications CSA IEC CSA IEC H/WFB V V V V Voltage Rating H/WFB V V H/WFB V AC V AC Maximum Current A A A Wire Range (Rated Cross Section) #. mm #. mm Wire Strip Length. in. (. mm). in. ( mm) Recommended Tightening Torque. lb in (. N m).. lb in (.. N m) Density pcs/ft (pcs /m) pcs/ft ( pcs/m) Housing Temperature Range - + F (- + C) - + F (- + C) Indicator Type H/WFB Non-Indicating Non-Indicating H/WFB Red LED Red LED H/WFB Neon Neon Leakage Current H/WFB H/WFB V V H/WFB V V Fuse Size (Not Supplied) / x -/ in. x mm Short-Circuit Current Rating See page - Terminal Blocks Pkg Qty. Pkg Qty. Black No-indication -H -WFB Color: Black w/led -H -WFB Black w/neon -H -WFB Accessories Pkg Qty. Pkg Qty. Mounting Rails: m Symmetrical DIN (Steel) -DR -DR m Symmetrical DIN (Aluminum) -DR -DR m Hi-Rise Sym. DIN (Aluminum) -DR -DR m Angled Hi-Rise Sym. DIN (Steel) -DR -DR ft Scored A-B Rail -N ft Rigid A-B Rail -N ft High Rise A-B Rail -N Standoff Brackets (Use Every in.) -N End Barrier -N Not Required End Anchors and Retainers: -ERL -ERL DIN Rail Normal Duty -EAJ -EAJ DIN Rail Heavy Duty -EAHJ -EAHJ A-B Rail Heavy Duty -N -Pole Side Jumper -N -SJFB- Side Jumper Insulating Sleeve -SJS Other Accessories: Partition Plate -PPSL Marking Systems: -MSX (/card) Snap-In Marker Card For Base Block -MSX (/card) For Handle -MSX (/card) -MSX (/card) -MSX (/card) Adhesive Labels -ALHFB (/sheet) -ALHFB (/card) IEC standards for x mm fuses do not include ratings above. A. -N is uninsulated. -SJFB- is insulated.." (. mm)." ( mm) Publication A-CAA-EN-P -

11 Bulletin Screw Connection Terminal Blocks Fuse Blocks -JDFB Dimensions are not intended to be used for manufacturing purposes. Note: Height dimension is measured from top of rail to top of terminal block.." ( mm)." (mm)." (. mm) Two-level terminal block with feed-through circuit and hinged-arm fuse circuit." (. mm) -JDGFB." (. mm)." ( mm) Three-Level terminal block with feed-through circuit, hinged-arm fuse circuit, and ground point Certifications CSA IEC CSA IEC Voltage Rating V V V V Maximum Fuse Circuit A A/V A A/V. A Current Feed-through Circuit A A A A. A Wire Range (Rated Cross Section) # #. mm # #. mm Fuse Size (Not Supplied) x mm x mm Wire Strip Length. in. ( mm). in. ( mm) Recommended Tightening Torque. lb in (. N m). lb in (. N m) Density pcs/ft ( pcs/m) pcs/ft ( pcs/m) Housing Temperature Range - + F (- + C) - + F (- + C) Short-Circuit Current Rating See page - Terminal Blocks Pkg Qty. Pkg Qty. Color: Grey -JDFB -JDGFB Accessories Pkg Qty. Pkg Qty. Mounting Rails: m Symmetrical DIN (Steel) -DR -DR m Symmetrical DIN (Aluminum) -DR -DR m Hi-Rise Sym. DIN (Aluminum) -DR -DR m Angled Hi-Rise Sym. DIN (Steel) -DR -DR End Barrier Grey -EBJDFB -EBJDFB End Anchors: -ERL -ERL DIN Rail - Normal Duty -EAJ -EAJ DIN Rail - Heavy Duty -EAHJ -EAHJ Jumpers: Side Jumper -pole -SJA- -SJA- Side Jumper -pole -SJA- -SJA- Side Jumper -pole -SJA- -SJA- End Anchor Top Marker Carrier -GMC -GMC -GMC Top Marker Tag -MX (/card) -MX (/card) Marking Systems: Snap-in marker cards (Handle) -MX (/card) -MX (/card) Snap-in marker cards (Handle) -MRX (/card) -MRX (/card) Snap-in marker cards (Side) -MX (/card) -MX (/card) IEC standards for x mm fuses do not include ratings above. A. The Bulletin -GMC marker carrier installs directly on the top of a -EAJ end anchor or a -ERL end retainer for group marking purposes. - Publication A-CAA-EN-P

12 Bulletin Screw Connection Terminal Blocks Plug-In Connection Blocks Dimensions are not intended to be used for manufacturing purposes. Note: Height dimension is measured from top of rail to top of terminal block.." ( mm) -JC." (. mm)." (. mm) Feed-Through terminal block with plug-in comb connections on one side.." (. mm) -JDC." (. mm)." (. mm) Two Circuit terminal block with plug-in comb connection on one side of each circuit. Certifications CSA IEC CSA IEC Voltage Rating V V V V Maximum Current A A A ( x ) A ( x ) A. A Wire Range (Rated Cross Section) # #. mm # #. mm Wire Strip Length. in. ( mm). in. ( mm) Recommended Tightening Torque. lb in (. N m).. lb in (.. N m) Density pcs/ft ( pcs/m) pcs/ft ( pcs/m) Housing Temperature Range - + F (- + C) - + F (- + C) Short-Circuit Current Rating See page - Terminal Blocks Pkg Qty. Pkg Qty. Color: Grey -JC -JDC Socket Strips Pkg Qty. Pkg Qty. Color/Quantity Black/-Pole -QP- -QP- Black/-Pole -QP- -QP- Black/-Pole -QP- -QP- Black/-Pole -QP- -QP- Black/-Pole -QP- -QP- Black/-Pole -QP- -QP- Black/-Pole -QP- -QP- Black/-Pole -QP- -QP- Black/-Pole -QP- -QP- Black/-Pole -QP- -QP- Black/-Pole -QP- -QP- Accessories Pkg Qty. Pkg Qty. Mounting Rails: m Symmetrical DIN (Steel) -DR -DR m Symmetrical DIN (Aluminum) -DR -DR m Hi-Rise Sym. DIN (Aluminum) -DR -DR m Angled Hi-Rise Sym. DIN (Steel) -DR -DR Barrier Kit (Start/End) -BKJC -BKJDC End Anchors and Retainers: -ERL -ERL DIN Rail Normal Duty -EAJ -EAJ DIN Rail Heavy Duty -EAHJ -EAHJ Jumpers: Screw Center Jumper -pole -CJJ- Screw Center Jumper -pole -CJJ- Screw Center Jumper -pole -CJJ- Screw Center Jumper pole -CJJ- Screw Type Jumper Notching Tool -T Other Accessories: Open Pin Cover -PCJC -PCJC Group Marking Carrier -GM -GM Marking Systems: Snap-in marker cards -MX (/card) -MX (/card) Individual Marker Tabs (Single Char.) -MX (/card) -MX (/card) One kit consists of start barriers and end barriers. Barriers are required on both ends. Publication A-CAA-EN-P -

13 Bulletin Screw Connection Terminal Blocks Short-Circuit Curr ent Ratings Fuse Ratings -J -JP -JDSS -JD -JDC -JGTW -JDGC -JG -JF -JTW -JC -JDC -JKD -JDFB -JDF -JDGFB -JDPSSTP -JDPTP -JDGP -JDGPSS -JDGPSSTP -JDGPTP -JDG -JDPSS -JDP -J -JG -JKD -JTW -JQ -JGTW -JGQ -JKDTW -JKDQ -JKDTP -JDC -JD -JKDQTP -JKDTWTP -JSD -JKD -JCTB -J -JG -J -JG -J -JG -JND -J -JG -J -JG -J -JG -J -JG Wire Range Cu [] Overcurrent Protection Fuse Required Class/Max. Current Rating [A] Maximum Line Load J T RK RK G CC Voltage [V] SCCR, RMS SYM [A],,,,,,, / /, / /, /.../ /.../, / /, - Preferred availability cat. nos. are bold. Publication A-CAA-EN-P

14 Bulletin Screw Connection Terminal Blocks Short-Circuit Current Ratings Overcurrent Ratings Overcurrent Ratings Wire Range Cu [] (Line and Load) Overcurrent Protection Device Required Max. Current [A] SCCR, RMS Sym A Y/V SCCR, RMS Sym. A Y/V -J M-DE-,, -JGTW M-CE-B,, -JP M-CE-B,, -J M-CE-B,, -JD M-CE-B,, -JDC M-CE-B, -JDSS M-CE-A,, -JDGC M-CE-C, -JG MCE-C, -J M-FE-,, -JG M-DE-C,, -JTW M-DE-C,, -JQ M-DE-C, -JGTW M-DE-C, -JGQ M-DE-B,, -JKDTW M-CE-B,, -JKDQ M-CE-B,, -JKDTP M-CE-B,, -JDC M-CE-B,, -JD M-CE-B, -JKDQTP M-CE-C, -JKDTWTP M-CE-C, M-CE-A,, -J M-FE-,, -JG M-DE-C,, M-DE-C,, M-DE-C, M-DE-C, M-DE-B,, M-CE-B,, M-CE-B,, M-CE-B,, M-CE-B,, M-CE-B, M-CE-C, M-CE-C, M-CE-A,, Bulletin M does not have ratings at this voltage. Preferred availability cat. nos. are bold. Publication A-CAA-EN-P -

15 Bulletin Screw Connection Terminal Blocks Short-Circuit Current Ratings Overcurrent Ratings Wire Range Cu [] (Line and Load) Overcurrent Protection Device Required Max. Current [A] SCCR, RMS Sym A Y/V SCCR, RMS Sym. A V+ -JTW M-DE-,, -JC M-CE-B,, -JDC M-CE-B,, -JF M-CE-B,, -JDF M-CE-B,, -JKD M-CE-B, -JDFB M-CE-A,, -JDGFB M-CE-C, -JDPSSTP MCE-C, -JDPTP -JDGP -JDGPSS -JDGPSSTP -JDGPTP -JDG -JDP -JDPSS -JKD M-FE-,, -JSD M-DE-C,, -JCTB M-DE-C,, M-DE-C, M-DE-C, M-DE-B,, M-CE-B,, M-CE-B,, M-CE-B,, M-CE-B,, M-CE-B, M-CE-C, M-CE-C, M-CE-A,, -J -JG -J -JG -JND -J -JG -J -JG Wire Range Cu [] (Line and Load) Overcurrent Protection Device Required Max. Current [A] SCCR, RMS Sym A V+ SCCR, RMS Sym. A Y V+ M-HP-,, M-HP-,, M-HP-,, / M-HP-,, Wire Range Cu [] (Line and Load) Overcurrent Protection Device Required Max. Current [A] SCCR, RMS Sym A V+ SCCR, RMS Sym. A V+ -J / U-JX, / U-JX, -J / U-JX,, Bulletin M does not have ratings at this voltage. + Voltage terminal block was tested at for respective SCCR - Preferred availability cat. nos. are bold. Publication A-CAA-EN-P

16 Bulletin Spring-Clamp Connection Terminal Blocks Introduction Allen-Bradley spring-clamp terminal blocks generally have been designed to meet the requirements of one or more regulatory bodies. Most products have also been tested per additional standards. The following is a listing of some of the regulatory bodies and standards which apply to Allen-Bradley spring-clamp terminal block products. See the particular product description for information on specific certifications and ratings. (Underwriters Laboratories) Allen-Bradley spring-clamp terminal blocks with one of these ratings have been tested by Underwriters Laboratories and meet the requirements of one or more of the following United States Standards: UL E Equipment Wiring Terminals for Use with Aluminum and/or Copper Conductors UL Standard for Terminal Blocks Reference UL file E (Underwriters Laboratories) Allen-Bradley spring-clamp terminal blocks with this rating have been tested by Underwriters Laboratories and meet the requirements of one or more of the following Canadian Standards: CSA. No. Terminal Blocks Reference UL file E (Canadian Standards Association) Allen-Bradley spring-clamp terminal blocks with this rating have been tested by the Canadian Standards Association and meet the requirements of the following Canadian Standard: CSA. No. Terminal Blocks Reference CSA files Allen-Bradley spring-clamp terminal blocks listed in this catalog meet the requirements of the Low Voltage Directive put forth by the European Union. Devices have been tested and comply with one or more of the following European Norms: EN - Low Voltage Switchgear and Controlgear: General Rules EN -- Low Voltage Switchgear and Controlgear: Terminal Blocks for Copper Conductors EN -- Low Voltage Switchgear and Controlgear: Protective Conductor Terminal Blocks for Copper Conductors EN -- Low Voltage Switchgear and Controlgear: Safety Requirements for Fuse Terminal Blocks ATEX Devices listed in this catalog with ATEX ratings meet the following European Norms per DEMKO or KEMA, Approval Certification Bodies for the European Union: EN - Electrical Apparatus for Potentially Explosive Atmospheres General Requirements EN - Electrical Apparatus for Potentially Explosive Atmospheres Increased Safety e Contact your local Allen-Bradley distributor for a copy of the certificate. Ex e II Bulletin -L terminal blocks in this catalog meet the following Canadian Standards per Underwriters Laboratories: CAN/CSA E- Electrical Apparatus for Explosive Atmospheres Part General Requirements CAN/CSA E- Electrical Apparatus for Explosive Atmospheres Part Increased Safety e These products are suitable for Class I, Zone Hazardous Locations. Reference UL file E. Contact your local Allen-Bradley distributor for more information. AEx e II Allen-Bradley spring-clamp terminal blocks with an AEx e II rating meet the following United States Standard per Underwriters Laboratories: UL Standard for Electrical Equipment for Use in Class I, Zone,, and Hazardous (Classified) Locations These products are suitable for Class I, Zone Hazardous Locations. Reference UL file E. Contact your local Allen-Bradley distributor for more information. Lloyd s Register Bulletin -L terminal blocks in this catalog have been certified for use in marine, off-shore, and industrial installations per the following standard: Lloyd s Register Test Specification No. : Contact your local Allen-Bradley distributor for a copy of the certificate. Publication A-CAA-EN-P -

17 Bulletin Spring-Clamp Connection Terminal Blocks Introduction The Allen-Bradley Line of Spring-Clamp Terminal Blocks The Bulletin -L line of internationally approved spring-clamp IEC-style terminal blocks offers a variety of products that can make any application: Fast Reduces wiring time by more than % Practical Requires only a flat-head screwdriver for easy installation. Maintenance-free, no need to retighten Reliable Secure contact is durable under extreme conditions such as high-vibration applications Products Available in the -L Spring-Clamp Line Feed-Through Blocks, accommodating wire sizes from # # (. mm) Grounding Blocks for grounding a given circuit to the DIN Rail Multi-Circuit Blocks for doubling circuit wiring density Isolation Blocks for circuit isolation during testing and troubleshooting Plug-In Style Terminal Blocks accommodating component plugs, fuse plugs, and disconnect plugs Sensor Blocks for coordination of three-wire sensor groups with or without ground terminations Electrical Component Blocks which allow for the insertion of fixed components into control circuits. Components include diodes and surge suppression circuits Tie-Point Block (Cat. Nos. -LDC, LDC, LDC) Diode Block (Cat. Nos. -LDDF, -LDDR) Uses a N diode between the upper and lower levels for insertion into a control circuit. This block is useful in low voltage DC control circuits for directioning and suppression. N -Pole Tie-Point Block Surge Suppression Block ( -LDSS) Provides a convenient means of incorporating transient suppression for relays, contactors and solenoids into a control system. V Line Coil -LDDF -LDDR Surge Supp. (MOV) Test Blocks for allowing a bank of pluggable terminal strips to be easily connected for test purposes A wide variety of snap-in markers are available for individual or group circuit identification A broad offering of accessories such as screwless end retainers, electrical warning plates, end barriers, protective stops and test plugs to provide exactly what the application requires Operating instructions (printed on an adhesive label), for fixing inside a panel Mini-blocks available in rail-mount or panel-mount configurations Materials and Design Features The -L line is specially designed for safety, installation ease, and ruggedness. Features include: Tin-plated terminals and stainless steel spring clamps for resistance to corrosion and vibration Spring clamp design to minimize stress relaxation and maintain contact force, even under vibration Top wire entry for ease of installation Circuit testing with standard mm diameter test probe or stackable test plugs on most spring-clamp blocks Insulation stops to ensure electrical connection when using smaller gauge wires Markers that are visible after terminal blocks are wired Multiple marking options Common profiles to minimize stocking of accessories Self-extinguishing, polymide. housing materials with a flammability rating UL -V (-R terminal blocks have a UL -V flammability rating) Screwless center jumpers to simplify jumpering terminals together Note: To ensure proper wire termination, these blocks are designed to accept only one wire per terminal. - Publication A-CAA-EN-P

18 Bulletin Spring-Clamp Connection Terminal Blocks Mini-Blocks with Center Jumper Option -LMJ Dimensions are not intended to be used for manufacturing purposes. Note: Height dimension is measured from top of rail to top of terminal block.." (. mm)." (. mm) -LMJG." (. mm)." ( mm)." ( mm) Mini rail-mount, feed-through terminal block with jumper capability Mini rail-mount grounding terminal block Certifications CSA IEC ATEX CSA IEC Voltage Rating V V V." (. mm) Maximum Current A A A Grounding Wire Range (Rated Cross Section) #. mm # #. mm Wire Strip Length. in. ( mm). in. ( mm) Density pcs/ft ( pcs/m) pcs/ft ( pcs/m) Housing Temperature Range - + F (- + C) + F ( + C) Terminal Blocks Pkg Qty. Pkg Qty. Color Grey -LMJ Blue -LMJ-B Green/Yellow -LMJG Accessories Pkg Qty. Pkg Qty. Mounting Rails m Symmetrical DIN (Steel) -DR -DR Grey -ERL -ERL End Anchor Grey -EAJ -EAJ Jumpers Plug-in Center Jumper -Pole -CJLJ- Plug-in Center Jumper -Pole -CJLJ- Plug-in Center Jumper -Pole -CJLJ- Plug-in Center Jumper -Pole -CJLJ- Plug-in Center Jumper -Pole -CJLJ- Plug-in Center Jumper -Pole -CJLJ- Plug-in Center Jumper -Pole -CJLJ- Plug-in Center Jumper -Pole -CJLJ- Plug-in Center Jumper -Pole -CJLJ- Plug-in Center Jumper -Pole -CJLJ- Side Jumper -Pole -SJLM- Side Jumper Installation Tool -TAL- End Barriers Grey -EBLMJ -EBLMJ Blue -EBLMJ-B -EBLMJ-B Yellow -EBLMJ-Y -EBLMJ-Y Marking Systems Snap-in Marker Cards -SMX (/card) -SMX (/card) Snap-In Marker Cards -MX (/card) -MX (/card) Hinged marker cards -MHX (/card) -MHX (/card) Markers can be installed over center jumper channel, with or without center jumper installed. Publication A-CAA-EN-P -

19 Bulletin Spring-Clamp Connection Terminal Blocks Mini-Blocks, Interlocking, V UL Rated Dimensions are not intended to be used for manufacturing purposes. Note: Height dimension is measured from top of rail to top of terminal block.." (. mm)." (. mm) -LM -LMQ -LMG." (. mm)." ( mm)." ( mm)." ( mm) Mini rail-mount, feed-through Mini rail-mount, feed-through Mini rail-mount grounding terminal block with connection terminal block terminal block points on each side Certifications CSA IEC CSA IEC CSA IEC Voltage Rating V V." (. mm) V V." (. mm)." (. mm) Maximum Current A A A A A A Grounding Wire Range (Rated Cross Section) #. mm #. mm #. mm Wire Strip Length. in. ( mm). in. ( mm). in. ( mm) Density pcs/ft ( pcs/m) pcs/ft ( pcs/m) pcs/ft ( pcs/m) Housing Temperature Range - + F (- + C) - + F (- + C) - + F (- + C) Terminal Blocks Pkg Qty. Pkg Qty. Pkg Qty. Color Grey -LM -LMQ Blue -LM-B -LMQ-B Green/Yellow -LMG Accessories Pkg Qty. Pkg Qty. Pkg Qty. Mounting Rails m Symmetrical Mini DIN (Steel) -DR -DR -DR Grey -ERL -ERL -ERL End Anchor Grey -EAJ -EAJ -EAJ Jumpers Side Jumper -Pole -SJLM- -SJLM- Side Jumper Installation Tool -TAL- -TAL- End Barriers Grey -EBLM -EBLM -EBLM Blue -EBLM-B -EBLM-B -EBLM-B Yellow -EBLM-Y -EBLM-Y -EBLM-Y Marking Systems Snap-In Marker Cards -MX (/card) -MX (/card) -MX (/card) Snap-In Marker Cards -MX (/card) -MX (/card) -MX (/card) Hinged Marker Cards -MHX (/card) -MHX (/card) -MHX (/card) - Publication A-CAA-EN-P

20 Bulletin Spring-Clamp Connection Terminal Blocks Mini-Blocks, Panel Mount -LMP Dimensions are not intended to be used for manufacturing purposes. Note: One end block and one end barrier or two end barriers must be used on each end of a terminal bank to provide mounting slots.." (. mm)." ( mm)." ( mm) Mini surface mount feed-through terminal block." ( mm) -LMPQ." (. mm)." ( mm) Mini surface mount, feed-through terminal block with connection points on each side Certifications CSA IEC CSA IEC Voltage Rating V V V V Maximum Current A A A A A A Wire Range (Rated Cross Section) #. mm #. mm Wire Strip Length. in. ( mm). in. ( mm) Density pcs/ft ( pcs/m) pcs/ft ( pcs/m) Housing Temperature Range - + F (- + C) - + F (- + C) Terminal Blocks Pkg Qty. Pkg Qty. Color Grey -LMP -LMPQ Blue -LMP-B -LMPQ-B End Terminal Blocks (with Mounting Brackets) Color Grey -LMPE -LMPQE Blue -LMPE-B -LMPQE-B Accessories Pkg Qty. Pkg Qty. Mounting Foot -MFLM -MFLM Jumpers Side Center Jumper -Pole -SJLM- -SJLM- Side Jumper Installation Tool -TAL- -TAL- End Barriers (with Mounting Slots) Grey -EBLMP -EBLMP Blue -EBLMP-B -EBLMP-B Marking Systems Snap-In Marker Cards -MX (/card) -MX (/card) Snap-In Marker Cards -MX (/card) -MX (/card) Hinged Marker Cards -MHX (/card) -MHX (/card) For a grouping of terminal blocks, use end terminal block, select the number of terminal blocks, and use end barrier. You can also use a group of terminal blocks with an end barrier on each end. Allows mounting to mm and mm DIN Rail. Recommended spacing is every fifth block on -LMP and every third block on - LMPQ. Publication A-CAA-EN-P -

21 Bulletin Spring-Clamp Connection Terminal Blocks Standard Feed-Through Blocks Dimensions are not intended to be used for manufacturing purposes. Note: Height dimension is measured from top of rail to top of terminal block.." (. mm) -L -LT -LQ." (. mm)." (. mm)." (. mm)." ( mm)." ( mm) Feed-through terminal block with Feed-through terminal block with Feed-through terminal block connection points on one side connection points per side Certifications CSA IEC ATEX CSA IEC ATEX CSA IEC ATEX Voltage Rating V V V." (. mm) V V V." (. mm) V V." (. mm) V Maximum Current A A. A A A A. A A A A. A A Wire Range (Rated Cross Section) #. mm. mm #. mm. mm #. mm. mm Wire Strip Length. in. ( mm). in. ( mm). in. ( mm) Density pcs/ft ( pcs/m) pcs/ft ( pcs/m) pcs/ft ( pcs/m) Housing Temperature Range - + F (- + C) - + F (- + C) + F ( + C) Terminal Blocks Pkg Qty. Pkg Qty. Color Grey -L -LT -LQ Red -L-RE -LT-RE -LQ-RE Blue -L-B -LT-B -LQ-B Black -L-BL -LT-BL -LQ-BL Green -L-G -LT-G -LQ-G Yellow -L-Y -LT-Y -LQ-Y Orange -L-OR -LT-OR -LQ-OR Brown -L-BR -LT-BR -LQ-BR White -L-W -LT-W -LQ-W Accessories Mounting Rails m Symmetrical DIN (Steel) Pkg Qty. Pkg Qty. -DR -DR -DR m Symmetrical DIN (Aluminum) -DR -DR -DR m Hi-Rise Sym. DIN (Aluminum) -DR -DR -DR m Angled Hi-Rise Sym. DIN (Steel) -DR -DR -DR End Barriers Grey -EBL -EBLT -EBLQ Blue -EBL-B -EBLT-B -EBLQ-B Yellow -EBL-Y -EBLT-Y -EBLQ-Y End Anchors and Retainers -ERL -ERL -ERL DIN Rail Normal Duty -EAJ -EAJ -EAJ DIN Rail Heavy Duty -EAHJ -EAHJ -EAHJ Jumpers Plug-in Center Jumper -Pole -CJL- -CJL- -CJL- Plug-in Center Jumper -Pole -CJL- -CJL- -CJL- Plug-in Center Jumper -Pole -CJL- -CJL- -CJL- Plug-in Center Jumper -Pole -CJL- -CJL- -CJL- Plug-in Center Jumper -Pole -CJL- -CJL- -CJL- Other Accessories Reducing Sleeves # # -PSL- -PSL- -PSL- (.. mm) White Reducing Sleeves # (.. mm) Grey -PSL- -PSL- -PSL- Test Plug (Stackable) -TPL -TPL -TPL Electrical Warning Plate -EWPL -EWPL -EWPL Marking Systems Snap-In Marker Cards -MX (/card) -MX (/card) -MX (/card) Snap-In Marker Cards -MX (/card) -MX (/card) -MX (/card) Pkg Qty. Pkg Qty. - Publication A-CAA-EN-P

22 Bulletin Spring-Clamp Connection Terminal Blocks Standard Feed-Through Blocks Dimensions are not intended to be used for manufacturing purposes. Note: Height dimension is measured from top of rail to top of terminal block.." (. mm) -L -LT -LQ." (. mm)." (. mm)." (. mm)." ( mm) Feed-through terminal block with Feed-through terminal block with Feed-through terminal block connection points, on one side points on each side Certifications CSA IEC ATEX CSA IEC ATEX CSA IEC ATEX Voltage Rating V V V." (. mm) V V." (. mm) V." (. mm) V V Maximum Current A A A A A A A A A A A A Wire Range (Rated Cross Section) # #. mm. mm ( ) # #. mm. mm ( ) # #. mm Wire Strip Length. in. ( mm). in. ( mm). in. ( mm) Density pcs/ft ( pcs/m) pcs/ft ( pcs/m) pcs/ft ( pcs/m) Housing Temperature Range - + F (- + C) - + F (- + C) + F ( + C) Short-Circuit Current Rating (SCCR) See page -." (. mm) V. mm ( ) Terminal Blocks Pkg Qty. Pkg Qty. Pkg Qty. Color Grey -L -LT -LQ Red -L-RE -LT-RE -LQ-RE Blue -L-B -LT-B -LQ-B Black -L-BL -LT-BL -LQ-BL Green -L-G -LT-G -LQ-G Yellow -L-Y -LT-Y -LQ-Y Orange -L-OR -LT-OR -LQ-OR Brown -L-BR -LT-BR -LQ-BR White -L-W -LT-W -LQ-W Accessories Pkg Qty. Pkg Qty. Pkg Qty. Mounting Rails m Symmetrical DIN (Steel) -DR -DR -DR m Symmetrical DIN (Aluminum) -DR -DR -DR m Hi-Rise Sym. DIN (Aluminum) -DR -DR -DR m Angled Hi-Rise Sym. DIN (Steel) -DR -DR -DR End Barriers Grey -EBL -EBLT -EBLQ Blue -EBL-B -EBLT-B -EBLQ-B Yellow -EBL-Y -EBLT-Y -EBLQ-Y End Anchors and Retainers -ERL -ERL -ERL DIN Rail Normal Duty -EAJ -EAJ -EAJ DIN Rail Heavy Duty -EAHJ -EAHJ -EAHJ Jumpers Plug-in Center Jumper -Pole -CJK- -CJK- -CJK- Plug-in Center Jumper -Pole -CJK- -CJK- -CJK- Plug-in Center Jumper -Pole -CJK- -CJK- -CJK- Plug-in Center Jumper -Pole -CJK- -CJK- -CJK- Plug-in Center Jumper -Pole -CJK- -CJK- -CJK- Plug-in Center Jumper -Pole -CJK- -CJK- -CJK- Plug-in Center Jumper -Pole -CJK- -CJK- -CJK- Plug-in Center Jumper -Pole -CJK- -CJK- -CJK- Plug-in Center Jumper -Pole -CJK- -CJK- -CJK- Plug-in Center Jumper -Pole -CJK- -CJK- -CJK- Other Accessories Reducing Sleeves # # -PSL- -PSL- -PSL- (.. mm) White Reducing Sleeves # # (.. mm) Grey -PSL- -PSL- -PSL- Reducing Sleeves # (.. mm) Dark Grey -PSL- -PSL- -PSL- Test Plug -TP -TP -TP Test Plug (Stackable) -TPL -TPL -TPL Electrical Warning Plate -EWPL -EWPL -EWPL Marking Systems Snap-In Marker Cards -MX (/card) -MX (/card) -MX (/card) Snap-In Marker Cards -MX (/card) -MX (/card) -MX (/card) Hinged Marker Cards -MHX (/card) -MHX (/card) -MHX (/card) Hinged Marker Cards -MHX (/card) -MHX (/card) -MHX (/card) Publication A-CAA-EN-P -

23 Bulletin Spring-Clamp Connection Terminal Blocks Standard Feed-Through Blocks Dimensions are not intended to be used for manufacturing purposes. Note: Height dimension is measured from top of rail to top of terminal block.." (. mm) -L -LT -LQ." (. mm)." (. mm)." ( mm)." ( mm)." ( mm) Feed-through terminal block Feed-through terminal block with Feed-through terminal block with connection points, on one side connection points on each side Certifications CSA IEC ATEX CSA IEC ATEX CSA IEC ATEX Voltage Rating V V V." (. mm) V V V." (. mm) V V Maximum Current A A A A A A A A A A A A Wire Range (Rated Cross Section) # mm mm ( ) # mm mm ( ) # Wire Strip Length. in. ( mm). in. ( mm). in. ( mm) Density pcs/ft ( pcs/m) pcs/ft ( pcs/m) pcs/ft ( pcs/m) Housing Temperature Range - + F (- + C) - + F (- + C) - + F (- + C) Short-Circuit Current Rating See page - mm." (. mm) V mm ( ) Terminal Blocks Pkg Qty. Pkg Qty. Pkg Qty. Color Grey -L -LT -LQ Red -L-RE -LT-RE -LQ-RE Blue -L-B -LT-B -LQ-B Black -L-BL -LT-BL -LQ-BL Green -L-G -LT-G -LQ-G Yellow -L-Y -LT-Y -LQ-Y Orange -L-OR -LT-OR -LQ-OR Brown -L-BR -LT-BR -LQ-BR White -L-W -LT-W -LQ-W Accessories Pkg Qty. Pkg Qty. Pkg Qty. Mounting Rails m Symmetrical DIN (Steel) -DR -DR -DR m Symmetrical DIN (Aluminum) -DR -DR -DR m Hi-Rise Sym. DIN (Aluminum) -DR -DR -DR m Angled Hi-Rise Sym. DIN (Steel) -DR -DR -DR End Barriers Grey -EBL -EBLT -EBLQ Blue -EBL-B -EBLT-B -EBLQ-B Yellow -EBL-Y -EBLT-Y -EBLQ-Y End Anchors and Retainers -ERL -ERL -ERL DIN Rail Normal Duty -EAJ -EAJ -EAJ DIN Rail Heavy Duty -EAHJ -EAHJ -EAHJ Jumpers: Plug-in Center Jumper -Pole -CJK- -CJK- -CJK- Plug-in Center Jumper -Pole -CJK- -CJK- -CJK- Plug-in Center Jumper -Pole -CJK- -CJK- -CJK- Plug-in Center Jumper -Pole -CJK- -CJK- -CJK- Plug-in Center Jumper -Pole -CJK- -CJK- -CJK- Plug-in Center Jumper -Pole -CJK- -CJK- -CJK- Plug-in Center Jumper -Pole -CJK- -CJK- -CJK- Plug-in Center Jumper -Pole -CJK- -CJK- -CJK- Plug-in Center Jumper -Pole -CJK- -CJK- -CJK- Other Accessories Reducing Sleeves # # -PSL- -PSL- -PSL- (.. mm) White Reducing Sleeves # # (.. mm) Grey -PSL- -PSL- -PSL- Reducing Sleeves # (.. mm) Dark Grey -PSL- -PSL- -PSL- Test Plug -TP -TP -TP Test Plug (Stackable) -TPL -TPL -TPL Electrical Warning Plate -EWPL -EWPL -EWPL Marking Systems Snap-In Marker Cards -MX (/card) -MX (/card) -MX (/card) Snap-In Marker Cards -MX (/card) -MX (/card) -MX (/card) Hinged Marker Cards -MHX (/card) -MHX (/card) -MHX (/card) - Publication A-CAA-EN-P

24 Bulletin Spring-Clamp Connection Terminal Blocks Standard Feed-Through Blocks Dimensions are not intended to be used for manufacturing purposes. Note: Height dimension is measured from top of rail to top of terminal block.." ( mm) -L -LT -L." (. mm)." ( mm)." ( mm)." (. mm) Feed-through terminal block Feed-through terminal block with connection points on one side Feed-through terminal block Certifications CSA IEC ATEX CSA IEC ATEX CSA IEC ATEX Voltage Rating V V V." ( mm) V V." (. mm) V." (. mm) V V." (. mm) V Maximum Current A A A A A A A A A A Wire Range (Rated Cross Section) mm mm mm # # mm # # ( mm (# # mm ( ) ) ) Wire Strip Length. in. ( mm). in. ( mm). in. ( mm) Density pcs/ft ( pcs/m) pcs/ft( pcs/m) pcs/ft ( pcs/m) Housing Temperature Range - + F (- + C) - + F (- + C) - + F (- + C) Short-Circuit Current Rating See page - Terminal Blocks Pkg Qty. Pkg Qty. Pkg Qty. Color Grey -L -LT -L Red -L-RE -LT-RE -L-RE Blue -L-B -LT-B -L-B Black -L-BL -LT-BL -L-BL Green -L-G -LT-G -L-G Yellow -L-Y -LT-Y -L-Y Orange -L-OR -LT-OR -L-OR Brown -L-BR -LT-BR -L-BR White -L-W -LT-W -L-W Accessories Pkg Qty. Pkg Qty. Pkg Qty. Mounting Rails m Symmetrical DIN (Steel) -DR -DR -DR m Symmetrical DIN (Aluminum) -DR -DR -DR m Hi-Rise Sym. DIN (Aluminum) -DR -DR -DR m Angled Hi-Rise Sym. DIN (Steel) -DR -DR -DR End Barriers Grey -EBL -EBLT -EBL Blue -EBL-B -EBLT-B -EBL-B Yellow -EBL-Y -EBLT-Y -EBL-Y End Anchors and Retainers -ERL -ERL -ERL DIN Rail Normal Duty -EAJ -EAJ -EAJ DIN Rail Heavy Duty -EAHJ -EAHJ -EAHJ Jumpers Plug-in Center Jumper -Pole -CJL- -CJL- Plug-in Center Jumper -Pole -CJL- -CJL- Plug-in Center Jumper -Pole -CJL- -CJL- Plug-in Center Jumper -Pole -CJL- -CJL- -CJL- Other Accessories Test Plug -TP Test Plug (Stackable) -TPL -TPL Electrical Warning Plate -EWPL -EWPL -EWPL Marking Systems Snap-In Marker Cards -MX (/card) -MX (/card) -MX (/card) Snap-In Marker Cards -MRX (/card) -MX (/card) -MX (/card) Hinged Marker Cards -MHX (/card) -MHX (/card) -MHX (/card) May only be mounted in terminal block corner marking positions. Publication A-CAA-EN-P -

25 Bulletin Spring-Clamp Connection Terminal Blocks Standard Feed-Through Blocks Dimensions are not intended to be used for manufacturing purposes. Note: Height dimension is measured from top of rail to top of terminal block.." (. mm) -L -LD -L." (. mm)." (. mm)." (. mm)." (. mm)." (. mm) Feed-through terminal block Power distribution block with center jumper connection/feed Feed-through terminal block Certifications CSA IEC ATEX CSA IEC CSA IEC ATEX Voltage Rating V V V." (. mm)." (. mm) V V V V Maximum Current A A A A A A A A Wire Range (Rated Cross Section) # mm mm ( ) # mm # mm Wire Strip Length. in. ( mm). in. ( mm). in. ( mm) Density pcs/ft ( pcs/m) pcs/ft ( pcs/m) pcs/ft ( pcs/m) Housing Temperature Range - + F (- + C) - + F (- + C) - + F (- + C) Short-Circuit Current Rating See page -." (. mm) V Terminal Blocks Pkg Qty. Pkg Qty. Pkg Qty. Color Grey -L -LD -L Red -L-RE -L-RE Blue -L-B -L-B Black -L-BL -L-BL Green -L-G -L-G Yellow -L-Y -L-Y Orange -L-OR -L-OR Brown -L-BR -L-BR White -L-W -L-W Accessories Pkg Qty. Pkg Qty. Pkg Qty. Mounting Rails m Symmetrical DIN (Steel) -DR -DR -DR m Symmetrical Heavy Duty DIN (Steel, Unslotted) -DR -DR -DR m Symmetrical DIN (Aluminum) -DR -DR -DR m Hi-Rise Symmetrical DIN (Aluminum) -DR -DR -DR m Angled Hi-Rise Sym. DIN (Steel) -DR -DR -DR m Symmetrical Heavy Duty DIN (Copper, Unslotted) -DR -DR -DR m Symmetrical Heavy Duty DIN (Steel Slotted) -DR -DR -DR End Barriers Grey -EBL Integrated to Block Integrated to Block Blue -EBL-B Yellow -EBL-Y End Anchors and Retainers -ERL -ERL -ERL DIN Rail Normal Duty -EAJ -EAJ -EAJ DIN Rail Heavy Duty -EAHJ -EAHJ -EAHJ Jumpers Plug-in Center Jumper -Pole -CJL- -CJL- Other Accessories Test Plug -TP -TP -TP Test Adapter Electrical Warning Plate -EWPL -EWPL -EWPL Marking Systems Snap-In Marker Cards -MX (/card) -MX (/card) -MX (/card) Snap-In Marker Cards -MX (/card) -MX (/card) -MX (/card) Hinged Marker Cards -MHX (/card) -MHX (/card) -MHX (/card) Can be electrically connected through center jumper for power distribution to - L, LQ, L, LT, LQ, L, and LT terminal blocks. See page - for distribution guidelines. Use defined center jumper for standard terminal blocks when connecting for power distribution. May only be mounted in terminal block corner marking positions. mm - Publication A-CAA-EN-P

26 Feed Left: Bulletin Spring-Clamp Connection Terminal Blocks Feed Right: Power Distribution Blocks The -LD feed terminal allows wires with a cross section from and up to mm to be used. Using standard cross connections, the potential can be distributed to any number of terminals with smaller cross sections. The following tables show some variants for potential distribution of the supply, the required cross connection, and the maximum current. The maximum current for the single terminal block must not be exceeded. Feed Middle: Feed Left Feed Middle Feed Right Feed Terminal Feed I max Jumper Feed Terminal Feed I max Jumper Feed Terminal Feed I max Jumper -L A -CJK- -L A -CJK- -L A -CJK- -LQ A -CJK- -LQ A -CJK- -LQ A -CJK- -L A -CJK- -L # A -CJK- -L # A -CJK- -LT A -CJK- ( mm) ( mm) -LQ ( mm) A -CJK- -L A -CJL- -L A -CJL- -L A -CJL- -LT A -CJL- See accessory section for availability of specific jumper pole configurations. Publication A-CAA-EN-P -

27 Bulletin Spring-Clamp Connection Terminal Blocks Multi-Circuit Feed-Through Blocks Dimensions are not intended to be used for manufacturing purposes. Note: Height dimension is measured from top of rail to top of terminal block.." ( mm) -LD -LD -LQS." ( mm)." (. mm)." (. mm)." (. mm)." (. mm)." (. mm)." ( mm) Two-circuit feed-through terminal block Two-circuit feed-through terminal block Side-by-side two circuit terminal block Certifications CSA IEC CSA IEC ATEX CSA IEC ATEX Voltage Rating V V V V V V V V V Maximum Current A. A A A A A A A A A Wire Range (Rated Cross Section) #. mm #. mm... mm mm #. mm ( (# ) ) Wire Strip Length. in. ( mm). in. ( mm). in. ( mm) Density pcs/ft ( pcs/m) pcs/ft ( pcs/m) pcs/ft ( pcs/m) Housing Temperature Range - + F (- + C) - + F (- + C) - + F (- + C) Terminal Blocks Pkg Qty. Pkg Qty. Pkg Qty. Color Grey -LD -LD -LQS Red -LD-RE -LD-RE -LQS-RE Blue -LD-B -LD-B -LQS-B Black -LD-BL -LD-BL -LQS-BL Green -LD-G -LD-G -LQS-G Yellow -LD-Y -LD-Y -LQS-Y Orange -LD-OR -LD-OR -LQS-OR Brown -LD-BR -LD-BR -LQS-BR White -LD-W -LD-W -LQS-W Accessories Pkg Qty. Pkg Qty. Pkg Qty. Mounting Rails m Symmetrical DIN (Steel) -DR -DR -DR m Symmetrical DIN (Aluminum) -DR -DR -DR m Hi-Rise Symmetrical DIN (Aluminum) -DR -DR -DR m Angled Hi-Rise Sym. DIN (Steel) -DR -DR -DR End Barriers Grey -EBLD -EBLD -EBLQ Blue -EBLD-B -EBLD-B -EBLQ-B Yellow -EBLD-Y -EBLD-Y -EBLQ-Y End Anchors and Retainers -ERL -ERL -ERL DIN Rail Normal Duty -EAJ -EAJ -EAJ DIN Rail Heavy Duty -EAHJ -EAHJ -EAHJ Jumpers Plug-in Center Jumper -Pole -CJK- Plug-in Center Jumper -Pole -CJL- -CJK- Plug-in Center Jumper -Pole -CJK- Plug-in Center Jumper -Pole -CJK- Plug-in Center Jumper -Pole -CJK- Plug-in Center Jumper -Pole -CJK- Plug-in Center Jumper -Pole -CJL- -CJK- Plug-in Center Jumper -Pole -CJL- -CJK- Plug-in Center Jumper -Pole -CJL- -CJK- Plug-in Center Jumper -Pole -CJL- -CJK- Other Accessories Reducing Sleeves # -PSL- -PSLS- -PSL- (.. mm) Reducing Sleeves # (.. mm) -PSL- -PSLS- -PSL- Reducing Sleeves # (.. mm) -PSL- Test Plug -TPL -TP -TPL Electrical Warning Plate -EWPL -EWPL -MX -MX Marking Systems (/card) (/card) -MX (/card) Snap-In Marker Cards -MX -MX (/card) (/card) -MX (/card) Hinged Marker Cards -MHX (/card) May only be mounted in terminal block corner marking positions.." (. mm) - Publication A-CAA-EN-P

28 Bulletin Spring-Clamp Connection Terminal Blocks Multi-Circuit Feed-Through Blocks Dimensions are not intended to be used for manufacturing purposes. Note: Height dimension is measured from top of rail to top of terminal block.." (. mm) -LD." (. mm)." ( mm) -LTF." (. mm)." (. mm)." ( mm) Two-circuit feed-through terminal block Three-circuit feed-through terminal block with multiple cross connection points Certifications CSA IEC CSA IEC Voltage Rating V V V V Maximum Current A A A A A Wire Range (Rated Cross Section) # mm #. mm Wire Strip Length. in. ( mm). in. ( mm) Density pcs/ft ( pcs/m) pcs/ft ( pcs/m) Housing Temperature Range - + F (- + C) - + F (- + C) Terminal Blocks Pkg Qty. Pkg Qty. Color Grey -LD -LTF Red -LD-RE Blue -LD-B Black -LD-BL Green -LD-G Yellow -LD-Y Orange -LD-OR Brown -LD-BR White -LD-W Accessories Pkg Qty. Pkg Qty. Mounting Rails m Symmetrical DIN (Steel) -DR -DR m Symmetrical DIN (Aluminum) -DR -DR m Hi-Rise Sym. DIN (Aluminum) -DR -DR m Angled Hi-Rise Sym. DIN (Steel) -DR -DR End Barriers Grey -EBLD -EBLTF Blue -EBLD-B Yellow -EBLD-Y End Anchors and Retainers -ERL -ERL DIN Rail Normal Duty -EAJ -EAJ DIN Rail Heavy Duty -EAHJ -EAHJ Jumpers Plug-in Center Jumper -Pole -CJK- Plug-in Center Jumper -Pole -CJK- -CJK- Plug-in Center Jumper -Pole -CJK- -CJK- Plug-in Center Jumper -Pole -CJK- -CJK- Plug-in Center Jumper -Pole -CJK- -CJK- Plug-in Center Jumper -Pole -CJK- -CJK- Plug-in Center Jumper -Pole -CJK- -CJK- Plug-in Center Jumper -Pole -CJK- -CJK- Plug-in Center Jumper -Pole -CJK- -CJK- Plug-in Center Jumper -Pole -CJK- -CJK- Vertical Cross Connector -CJLD Other Accessories Reducing Sleeves -PSLTF- (.. mm) Reducing Sleeves (.. mm) -PSLTF- Test Plug -TP Electrical Warning Plate -EWPL Marking Systems Snap-In Marker Cards -MX (/card) -SMX (/card) Snap-In Marker Cards -MX (/card) -MX (/card) Used to electrically connect levels of -LTF Publication A-CAA-EN-P -

29 Bulletin Spring-Clamp Connection Terminal Blocks Specialty Feed-Through Blocks Dimensions are not intended to be used for manufacturing purposes. Note: Height dimension is measured from top of rail to top of terminal block.." ( mm) -LDC -LDC -LDC." (. mm)." (. mm)." ( mm)." (. mm)." ( mm) Two-level feed-through terminal Two-level feed-through terminal block with Two-level feed-through terminal block with commoning bar commoning bar block with commoning bar Certifications CSA IEC CSA IEC ATEX CSA IEC Voltage Rating V V V." (. mm) V V V." (. mm) V." (. mm) V Maximum Current A. A A A A A A A A.. Wire Range (Rated Cross Section) #. mm #. mm mm (# ) # mm Wire Strip Length. in. ( mm). in. ( mm). in. ( mm) Density pcs/ft ( pcs/m) pcs/ft ( pcs/m) pcs/ft ( pcs/m) Housing Temperature Range - + F (- + C) - + F (- + C) - + F (- + C) Terminal Blocks Pkg Qty. Pkg Qty. Pkg Qty. Color: Grey -LDC -LDC -LDC Accessories Pkg Qty. Pkg Qty. Pkg Qty. Mounting Rails: m Symmetrical DIN (Steel) -DR -DR -DR m Symmetrical DIN (Aluminum) -DR -DR -DR m Hi-Rise Sym. DIN (Aluminum) -DR -DR -DR m Angled Hi-Rise Sym. DIN (Steel) -DR -DR -DR End Barriers Grey -EBLD -EBLD -EBLD End Anchors and Retainers -ERL -ERL -ERL DIN Rail Normal Duty -EAJ -EAJ -EAJ DIN Rail Heavy Duty -EAHJ -EAHJ -EAHJ Jumpers: Plug-in Center Jumper -Pole -CJK- Plug-in Center Jumper -Pole -CJL- -CJK- -CJK- Plug-in Center Jumper -Pole -CJK- -CJK- Plug-in Center Jumper -Pole -CJK- -CJK- Plug-in Center Jumper -Pole -CJK- -CJK- Plug-in Center Jumper -Pole -CJK- -CJK- Plug-in Center Jumper -Pole -CJL- -CJK- -CJK- Plug-in Center Jumper -Pole -CJL- -CJK- -CJK- Plug-in Center Jumper -Pole -CJL- -CJK- -CJK- Plug-in Center Jumper -Pole -CJL- -CJK- -CJK- Other Accessories: Reducing Sleeves -PSL- -PSLS- (.. mm) White Reducing Sleeves (.. mm) Grey -PSL- -PSLS- Test Plug -TPL -TP Electrical Warning Plate -EWPL -EWPL Marking Systems: Snap-In Marker Cards -MX (/card) -MX (/card) -MX (/card) Snap-In Marker Cards -MX (/card) -MX (/card) -MX (/card) May only be mounted in terminal block corner marking positions. - Publication A-CAA-EN-P

30 Bulletin Spring-Clamp Connection Terminal Blocks Sensor Blocks -Wire -LS- -LS-L -LSG- -LS-BR -LS-B -LSG Dimensions are not intended to be used for manufacturing purposes. Note: Height dimension is measured from top of rail to top of terminal block.." (. mm)." (. mm)." (. mm)." (. mm)." (. mm)." ( mm)." ( mm)." (. mm) conductor sensor block base for conductor sensor ground block Plug in Distribution blocks plug in distribution blocks base for plug in distribution blocks internally jumpered Certifications CSA IEC CSA IEC CSA IEC Voltage Rating (without LED) V V V V." (. mm) V V Voltage Rating (with LED) V V Maximum Current A. A A. A A. A Wire Range (Rated Cross Section) #. mm #. mm #. mm Wire Strip Length. in. ( mm). in. ( mm). in. ( mm) Density pcs/ft ( pcs/m) pcs/ft ( pcs/m) pcs/ft ( pcs/m) Housing Temperature Range - + F (- + C) - + F (- + C) - + F (- + C) Terminal Blocks Pkg Qty. Pkg Qty. Pkg Qty. Color: Grey (Without LED) -LS- Grey (With LED) -LS-L Green/Yellow -LSG- -LSG Brown -LS-BR Blue -LS-B Accessories Pkg Qty. Pkg Qty. Pkg Qty. Mounting Rails: m Symmetrical DIN (Steel) -DR -DR m Symmetrical DIN (Aluminum) -DR -DR m Hi-Rise Sym. DIN (Aluminum) -DR -DR m Angled Hi-Rise Sym. DIN (Steel) -DR -DR End Barriers Grey -EBLS- -EBLS- Not required End Anchors and Retainers -ERL -ERL DIN Rail Normal Duty -EAJ -EAJ DIN Rail Heavy Duty -EAHJ -EAHJ Jumpers: Plug-in Center Jumper -Pole -CJK- Plug-in Center Jumper -Pole -CJK- Plug-in Center Jumper -Pole -CJK- Plug-in Center Jumper -Pole -CJK- Plug-in Center Jumper -Pole -CJK- Plug-in Center Jumper -Pole -CJK- Plug-in Center Jumper -Pole -CJK- Plug-in Center Jumper -Pole -CJK- Plug-in Center Jumper -Pole -CJK- Plug-in Center Jumper -Pole -CJK- Other Accessories: Reducing Sleeves -PSLS- -PSLS- (.. mm) White Reducing Sleeves (.. mm) Grey -PSLS- -PSLS- Marking Systems: Snap-In Marker Cards -MX (/card) -MX (/card) A combination of two distribution blocks must be used with each base block. Publication A-CAA-EN-P -

31 Bulletin Spring-Clamp Connection Terminal Blocks Sensor Blocks -Wire -LS- -LS-L -LSG- -LS-BR -LS-B -LSG Dimensions are not intended to be used for manufacturing purposes. Note: Height dimension is measured from top of rail to top of terminal block.." (. mm)." ( mm)." (. mm)." (. mm)." ( mm)." (. mm)." (. mm)." (. mm) conductor sensor block base for conductor sensor ground block Plug In Distribution blocks plug in distribution blocks base for plug in distribution blocks internally jumpered Certifications CSA IEC CSA IEC CSA IEC Voltage Rating (without LED) V V V V." (. mm) V V Voltage Rating (with LED) V V Maximum Current A. A A. A A. A Wire Range (Rated Cross Section) #. mm #. mm #. mm Wire Strip Length. in. ( mm). in. ( mm). in. ( mm) Density pcs/ft ( pcs/m) pcs/ft ( pcs/m) pcs/ft ( pcs/m) Housing Temperature Range - + F (- + C) - + F (- + C) - + F (- + C) Terminal Blocks Pkg Qty. Pkg Qty. Pkg Qty. Color: Grey (Without LED) -LS- Grey (With LED) -LS-L Green/Yellow -LSG- -LSG Brown -LS-BR Blue -LS-B Accessories Pkg Qty. Pkg Qty. Pkg Qty. Mounting Rails: m Symmetrical DIN (Steel) -DR -DR m Symmetrical DIN (Aluminum) -DR -DR m Hi-Rise Sym. DIN (Aluminum) -DR -DR m Angled Hi-Rise Sym. DIN (Steel) -DR -DR End Barriers Grey -EBLS- -EBLS- Not required End Anchors and Retainers -ERL -ERL DIN Rail Normal Duty -EAJ -EAJ DIN Rail Heavy Duty -EAHJ -EAHJ Jumpers: Plug-in Center Jumper -Pole -CJK- Plug-in Center Jumper -Pole -CJK- Plug-in Center Jumper -Pole -CJK- Plug-in Center Jumper -Pole -CJK- Plug-in Center Jumper -Pole -CJK- Plug-in Center Jumper -Pole -CJK- Plug-in Center Jumper -Pole -CJK- Plug-in Center Jumper -Pole -CJK- Plug-in Center Jumper -Pole -CJK- Plug-in Center Jumper -Pole -CJK- Other Accessories: Reducing Sleeves -PSLS- -PSLS- (.. mm) White Reducing Sleeves (.. mm) Grey -PSLS- -PSLS- Marking Systems: Snap-In Marker Cards -MX (/card) -MX (/card) A combination of three distribution blocks must be used with each base block. - Publication A-CAA-EN-P

32 Bulletin Spring-Clamp Connection Terminal Blocks Grounding Blocks Dimensions are not intended to be used for manufacturing purposes. Note: Height dimension is measured from top of rail to top of terminal block.." (. mm) -LG -LGT -LGQ." (. mm)." (. mm) Feed-through grounding terminal block." (. mm)." (. mm)." ( mm) Feed-through grounding terminal block with points on one side." (. mm)." ( mm)." (. mm) Feed-through grounding terminal block with points on each side Certifications CSA IEC ATEX CSA IEC ATEX CSA IEC ATEX Voltage Rating Maximum Current Grounding Grounding Grounding Wire Range (Rated Cross Section) #. mm. mm ( ) #. mm. mm ( ) # Wire Strip Length. in. ( mm). in. ( mm). in. ( mm) Density pcs/ft ( pcs/m) pcs/ft ( pcs/m) pcs/ft ( pcs/m) Housing Temperature Range - + F (- + C) - + F (- + C) - + F (- + C). mm. mm ( ) Terminal Blocks Pkg Qty. Pkg Qty. Pkg Qty. Color: Green/Yellow -LG -LGT -LGQ Accessories Pkg Qty. Pkg Qty. Pkg Qty. Mounting Rails: m Symmetrical DIN (Steel) -DR -DR -DR m Symmetrical DIN (Aluminum) -DR -DR -DR m Hi-Rise Symmetrical DIN (Aluminum) -DR -DR -DR m Angled Hi-Rise Sym. DIN (Steel) -DR -DR -DR End Barrier Yellow -EBL-Y -EBLT-Y -EBLQ-Y End Anchors and Retainers -ERL -ERL -ERL DIN Rail Normal Duty -EAJ -EAJ -EAJ DIN Rail Heavy Duty -EAHJ -EAHJ -EAHJ Other Accessories: Reducing Sleeves -PSL- -PSL- -PSL- (.. mm) White Reducing Sleeves (.. mm) Grey -PSL- -PSL- -PSL- Test Plug (Stackable) -TPL -TPL -TPL Marking Systems: Snap-In Marker Cards -MX (/card) -MX (/card) -MX (/card) Snap-In Marker Cards -MX (/card) -MX (/card) -MX (/card) Publication A-CAA-EN-P -

33 Bulletin Spring-Clamp Connection Terminal Blocks Grounding Blocks Dimensions are not intended to be used for manufacturing purposes. Note: Height dimension is measured from top of rail to top of terminal block.." (. mm) -LG -LGT -LGQ." (. mm)." (. mm) Feed-through grounding terminal block." (. mm)." (. mm)." (. mm) Feed-through grounding terminal block with points on one side." (. mm)." (. mm)." ( mm) Feed-through grounding terminal block with points on each side Certifications CSA IEC ATEX CSA IEC ATEX CSA IEC ATEX Voltage Rating Maximum Current Grounding Grounding Grounding Wire Range (Rated Cross Section) # #. mm. mm ( ) # #. mm. mm ( ) Wire Strip Length. in. ( mm). in. ( mm). in. ( mm) Density pcs/ft ( pcs/m) pcs/ft ( pcs/m) pcs/ft ( pcs/m) Housing Temperature Range - + F (- + C) - + F (- + C) - + F (- + C) # #. mm. mm ( ) Terminal Blocks Pkg Qty. Pkg Qty. Pkg Qty. Color: Green/Yellow -LG -LGT -LGQ Accessories Pkg Qty. Pkg Qty. Pkg Qty. Mounting Rails: m Symmetrical DIN (Steel) -DR -DR -DR m Symmetrical DIN (Aluminum) -DR -DR -DR m Hi-Rise Symmetrical DIN (Aluminum) -DR -DR -DR m Symmetrical Heavy Duty DIN (Steel) -DR -DR -DR End Barrier Yellow -EBL-Y -EBLT-Y -EBLQ-Y End Anchors and Retainers: -ERL -ERL -ERL DIN Rail Normal Duty -EAJ -EAJ -EAJ DIN Rail Heavy Duty -EAHJ -EAHJ -EAHJ Other Accessories: Reducing Sleeves -PSL- -PSL- -PSL- (.. mm) White Reducing Sleeves.. mm) Grey -PSL- -PSL- -PSL- Reducing Sleeves (.. mm) Dark Grey -PSL- -PSL- -PSL- Test Plug -TP -TP -TP Test Plug (Stackable) -TPL -TPL -TPL Marking Systems: Snap-In Marker Cards -MX (/card) -MX (/card) -MX (/card) Snap-In Marker Cards -MX (/card) -MX (/card) -MX (/card) Hinged Marker Cards -MHX (/card) -MHX (/card) -MHX (/card) Hinged Marker Cards -MHX (/card) -MHX (/card) -MHX (/card) - Publication A-CAA-EN-P

34 Bulletin Spring-Clamp Connection Terminal Blocks Grounding Blocks Dimensions are not intended to be used for manufacturing purposes. Note: Height dimension is measured from top of rail to top of terminal block.." (. mm) -LG -LGT -LGQ." (. mm)." ( mm) Feed-through grounding terminal block." (. mm)." ( mm)." (. mm) Feed-through grounding terminal block with points on one side." (. mm)." ( mm)." (. mm) Feed-through grounding terminal block with points on each side Certifications CSA IEC ATEX CSA IEC ATEX CSA IEC ATEX Voltage Rating Maximum Current Grounding Grounding Grounding Wire Range (Rated Cross Section) # mm mm ( ) # mm mm ( ) # Wire Strip Length. in. ( mm). in. ( mm). in. ( mm) Density pcs/ft ( pcs/m) pcs/ft ( pcs/m) pcs/ft ( pcs/m) Housing Temperature Range - + F (- + C) - + F (- + C) - + F (- + C) mm mm ( ) Terminal Blocks Pkg Qty. Pkg Qty. Pkg Qty. Color: Green/Yellow -LG -LGT -LGQ Accessories Pkg Qty. Pkg Qty. Pkg Qty. Mounting Rails: m Symmetrical DIN (Steel) -DR -DR -DR m Symmetrical DIN (Aluminum) -DR -DR -DR m Hi-Rise Symmetrical DIN (Aluminum) -DR -DR -DR m Angled Hi-Rise Sym. DIN (Steel) -DR -DR -DR End Barrier Yellow -EBL-Y -EBLT-Y -EBLQ-Y End Anchors and Retainers -ERL -ERL -ERL DIN Rail Normal Duty -EAJ -EAJ -EAJ DIN Rail Heavy Duty -EAHJ -EAHJ -EAHJ Other Accessories: Reducing Sleeves -PSL- -PSL- -PSL- (.. mm) White Reducing Sleeves (.. mm) Grey -PSL- -PSL- -PSL- Reducing Sleeves (.. mm) Dark Grey -PSL- -PSL- -PSL- Test Plug -TP -TP -TP Test Plug (Stackable) -TPL -TPL -TPL Marking Systems: Snap-In Marker Cards -MX (/card) -MX (/card) -MX (/card) Snap-In Marker Cards -MX (/card) -MX (/card) -MX (/card) Hinged Marker Cards -MHX (/card) -MHX (/card) -MHX (/card) Publication A-CAA-EN-P -

35 Bulletin Spring-Clamp Connection Terminal Blocks Grounding Blocks Dimensions are not intended to be used for manufacturing purposes. Note: Height dimension is measured from top of rail to top of terminal block.." ( mm) -LG -LGT -LG." (. mm)." ( mm) Feed-through grounding terminal block." ( mm)." ( mm)." (. mm) Feed-through grounding terminal block with points on one side." (. mm)." (. mm)." (. mm) Feed-through grounding terminal block Certifications CSA IEC ATEX CSA IEC ATEX CSA IEC ATEX Voltage Rating Maximum Current Grounding Grounding Grounding Wire Range (Rated Cross Section) # # mm mm ( ) # # mm mm ( ) # Wire Strip Length. in. ( mm). in. ( mm). in. ( mm) Density pcs/ft ( pcs/m) pcs/ft ( pcs/m) pcs/ft ( pcs/m) Housing Temperature Range - + F (- + C) - + F (- + C) - + F (- + C) mm mm ( ) Terminal Blocks Pkg Qty. Pkg Qty. Pkg Qty. Color: Green/Yellow -LG -LGT -LG Accessories Pkg Qty. Pkg Qty. Pkg Qty. Mounting Rails: m Symmetrical DIN (Steel) -DR -DR -DR m Symmetrical DIN (Aluminum) -DR -DR -DR m Hi-Rise Symmetrical DIN (Aluminum) -DR -DR -DR m Angled Hi-Rise Sym. DIN (Steel) -DR -DR -DR End Barrier Yellow -EBL-Y -EBLT-Y -EBL-Y End Anchors and Retainers -ERL -ERL -ERL DIN Rail Normal Duty -EAJ -EAJ -EAJ DIN Rail Heavy Duty -EAHJ -EAHJ -EAHJ Other Accessories: Test Plug -TPL -TPL -TP Marking Systems: Snap-In Marker Cards -MRX (/card) -MX (/card) -MX (/card) Snap-In Marker Cards -MX (/card) -MX (/card) -MX (/card) Hinged Marker Cards -MHX (/card) -MHX (/card) -MHX (/card) May only be mounted in terminal block corner marking positions. - Publication A-CAA-EN-P

36 Bulletin Spring-Clamp Connection Terminal Blocks Grounding Blocks Dimensions are not intended to be used for manufacturing purposes. Note: Height dimension is measured from top of rail to top of terminal block.." (. mm) -LG -LG -LDG." (. mm)." (. mm)." (. mm)." (. mm)." (. mm)." ( mm) Two-circuit terminal block with Feed-through grounding terminal block Feed-through grounding terminal block feed-through and ground circuit Certifications CSA IEC ATEX CSA IEC ATEX CSA IEC Voltage Rating V Maximum Current Grounding Grounding A. A Wire Range (Rated Cross Section) # # mm mm ( ) # mm mm (# ) #. (. mm V. mm Wire Strip Length. in. ( mm). in. ( mm). in. ( mm) Density pcs/ft ( pcs/m) pcs/ft ( pcs/m) pcs/ft ( pcs/m) Housing Temperature Range - + F (- + C) - + F (- + C) + F ( + C) Terminal Blocks Pkg Qty. Pkg Qty. Pkg Qty. Color: Green/Yellow -LG -LG Grey -LDG Accessories Pkg Qty. Pkg Qty. Pkg Qty. Mounting Rails: m Symmetrical DIN (Steel) -DR -DR -DR m Symmetrical Heavy Duty DIN (Steel, Unslotted) -DR -DR -DR m Symmetrical DIN (Aluminum) -DR -DR -DR m Hi-Rise Symmetrical DIN (Aluminum) -DR -DR -DR m Angled Hi-Rise Sym. DIN (Steel) -DR -DR -DR m Symmetrical Heavy Duty DIN (Copper, Unslotted) -DR -DR -DR m Symmetrical Heavy Duty DIN (Steel) -DR -DR -DR End Barrier Yellow -EBL-Y Integrated Grey -EBLD End Anchors and Retainers -ERL -ERL -ERL DIN Rail Normal Duty -EAJ -EAJ -EAJ DIN Rail Heavy Duty -EAHJ -EAHJ -EAHJ Other Accessories: Reducing Sleeves -PSL- (.. mm) White Reducing Sleeves (.. mm) Grey -PSL- Test Plug -TP -TP -TPL Electrical Warning Plate -EWPL Marking Systems: Snap-In Marker Cards -MX (/card) -MX (/card) Snap-In Marker Cards -MX (/card) -MX (/card) -MX (/card) -MX (/card) Hinged Marker Cards -MHX (/card) -MHX (/card) May only be mounted in terminal block corner marking positions. Publication A-CAA-EN-P -

37 Bulletin Spring-Clamp Connection Terminal Blocks Grounding Blocks Dimensions are not intended to be used for manufacturing purposes. Note: Height dimension is measured from top of rail to top of terminal block.." ( mm) -LDGC -LDG -LDGC." ( mm)." (. mm) Single-circuit, two-level grounding terminal block with connection points on each side." (. mm)." (. mm)." (. mm) Two-circuit grounding terminal block with feed-through and ground circuit." (. mm)." (. mm)." (. mm) Single-circuit, two-level grounding terminal block with connection points on each side Certifications CSA IEC CSA IEC ATEX CSA IEC ATEX Voltage Rating V V V Maximum Current Grounding A A A A Grounding Wire Range (Rated Cross Section) #. mm # #. mm.. mm (# ) # #. mm Wire Strip Length. in. ( mm). in. ( mm). in. ( mm) Density pcs/ft ( pcs/m) pcs/ft ( pcs/m) pcs/ft ( pcs/m) Housing Temperature Range - + F (- + C) - + F (- + C) - + F (- + C) Terminal Blocks Pkg Qty. Pkg Qty. Pkg Qty. Color: Green/Yellow -LDGC -LDGC Grey -LDG Accessories Pkg Qty. Pkg Qty. Pkg Qty. Mounting Rails: m Symmetrical DIN (Steel) -DR -DR -DR m Symmetrical DIN (Aluminum) -DR -DR -DR m Hi-Rise Symmetrical DIN (Aluminum) -DR -DR -DR m Angled Hi-Rise Sym. DIN (Steel) -DR -DR -DR End Barrier Yellow -EBLD-Y -EBLD-Y Grey -EBLD End Anchors and Retainers -ERL -ERL -ERL DIN Rail Normal Duty -EAJ -EAJ -EAJ DIN Rail Heavy Duty -EAHJ -EAHJ -EAHJ Other Accessories: Reducing Sleeves -PSL- -PSLS- -PSLS- (.. mm) White Reducing Sleeves.. mm) Grey -PSL- -PSLS- -PSLS- Test Plug (Stackable) -TPL Marking Systems: Snap-In Marker Cards Snap-In Marker Cards - MX (/card) -MX (/card) May only be mounted in terminal block corner marking positions. -MX (/card) -MX (/card) -MX (/card) -MX (/card).. mm ( ) - Publication A-CAA-EN-P

38 Bulletin Spring-Clamp Connection Terminal Blocks Grounding Blocks Dimensions are not intended to be used for manufacturing purposes. Note: Height dimension is measured from top of rail to top of terminal block.." (. mm) -LDG." (. mm)." ( mm) Two-circuit grounding terminal block with feed-through and ground circuit." (. mm) -LDGC." (. mm)." ( mm) Single-circuit, two-level grounding terminal block with connection points on each side Certifications CSA IEC CSA IEC Voltage Rating V V Maximum Current A A A Grounding Wire Range (Rated Cross Section) # mm # mm Wire Strip Length. in. ( mm). in. ( mm) Density pcs/ft ( pcs/m) pcs/ft ( pcs/m) Housing Temperature Range - + F (- + C) - + F (- + C) Terminal Blocks Pkg Qty. Pkg Qty. Color: Green/Yellow -LDGC Grey -LDG Accessories Pkg Qty. Pkg Qty. Mounting Rails: m Symmetrical DIN (Steel) -DR -DR m Symmetrical DIN (Aluminum) -DR -DR m Hi-Rise Symmetrical DIN (Aluminum) -DR -DR m Angled Hi-Rise Sym. DIN (Steel) -DR -DR End Barrier Yellow -EBLD-Y Grey -EBLD End Anchors and Retainers -ERL -ERL DIN Rail Normal Duty -EAJ -EAJ DIN Rail Heavy Duty -EAHJ -EAHJ Other Accessories: Test Plug -TP Electrical Warning Plate -EWPL Marking Systems: Snap-In Marker Cards -MX (/card) -MX (/card) Snap-In Marker Cards -MX (/card) -MX (/card) Publication A-CAA-EN-P -

39 Bulletin Spring-Clamp Connection Terminal Blocks Plug-in Style Blocks -LDP -LGP -LGTP Dimensions are not intended to be used for manufacturing purposes. Note: Height dimension is measured from top of rail to top of terminal block.." ( mm)." (. mm)." (. mm)." (. mm)." ( mm)." (. mm)." (. mm)." (. mm)." (. mm) - Two-circuit terminal block with fixed and plug-in connection on each level. Plug-in connectors can be individual or grouped configurations. Single-circuit grounding terminal block with fixed and plug-in connection. Single-circuit grounding terminal block with fixed and plug-in connection. Certifications CSA IEC CSA IEC CSA IEC Voltage Rating V V Maximum Current A A Grounding Grounding Limited Rating - Voltage V Limited Rating - Current A Wire Range (Rated Cross Section).. mm.. mm Wire Strip Length. in ( mm). in ( mm). in ( mm) Density (Blocks per ft/m) pcs/ft ( pcs/m) pcs/ft ( pcs/m) pcs/ft ( pcs/m) Housing Temperature Range - + F (- + C) - + F (- + C) - + F (- + C) Terminal Blocks Color Accessories Mounting Rails m Symmetrical DIN (Steel) Pcs/ Pkg Pcs/ Pkg Grey -LDP Green/Yellow -LGP -LGTP Pcs/ Pkg Pcs/ Pkg.. mm -DR -DR -DR m Symmetrical DIN (Aluminum) -DR -DR -DR m Hi-Rise Sym. DIN (Aluminum) -DR -DR -DR m Angled Hi-Rise Sym. DIN (Steel) -DR -DR -DR End Barrier Grey -EBLDP Yellow -EBLP-Y -EBLTP-Y End Anchors -ERL -ERL -ERL DIN Rail - Normal Duty -EAJ -EAJ -EAJ Din Rail - Heavy Duty -EAHJ -EAHJ -EAHJ Jumpers Plug-in Center Jumper Pole -CJLJ- Plug-in Center Jumper Pole -CJLJ- Plug-in Center Jumper Pole -CJLJ- Plug-in Center Jumper Pole -CJLJ- Plug-in Center Jumper Pole -CJLJ- Plug-in Center Jumper Pole -CJLJ- Plug-in Center Jumper Pole -CJLJ- Plug-in Center Jumper Pole -CJLJ- Plug-in Center Jumper Pole -CJLJ- Plug-in Center Jumper Pole -CJLJ- Individual Plug-in Connector Grey -STP Green -STP-G -STP-G -STP-G Ganged Connector - Start Plug Grey -SBSTP Ganged Connector - Middle Plug Grey -GSTP Ganged Connector - End Plug Grey -EBSTP Plug-In Component Accessories Locking Element Yellow -STPLE -STPLE -STPLE Coding Element Yellow -STPCE -STPCE -STPCE Strain Relief Yellow -STPSR -STPSR -STPSR Group Marking Rail Mount Group Marking Carrier -GM -GM -GM End Anchor Top Marker Carrier -GMC -GMC -GMC -GMC Top Marker Tag -MX(/card) -MX(/card) -MX(/card) Marking Systems -MRX -MRX -MRX Snap-in Marker Cards (/card) (/card) (/card) Snap-In Marker Cards -MRX (/card) -MRX (/card) -MRX (/card) The Bulletin -GMC marker carrier installs directly on the top of a -EAJ end anchor or a -ERL end retainer for group marking purposes. Blocks contain dual UL/CSA listings and can be used at V with a A rating or V with a A rating. For ganged configurations greater than, use multiple -GSTP plug-in blocks. Publication A-CAA-EN-P Pcs/ Pkg Pcs/ Pkg

40 Bulletin Spring-Clamp Connection Terminal Blocks Isolation Blocks Dimensions are not intended to be used for manufacturing purposes. Note: Height dimension is measured from top of rail to top of terminal block. -LKD." (. mm)." (. mm) Knife disconnect feed-through terminal block Certifications CSA IEC Voltage Rating V V Maximum Current A A Wire Range (Rated Cross Section) #. mm Wire Strip Length. in. ( mm) Density pcs/ft ( pcs/m) Housing Temperature Range - + F (- + C) Terminal Blocks Pkg Qty. Color Grey -LKD Accessories Pkg Qty. Mounting Rails m Symmetrical DIN (Steel) -DR m Symmetrical DIN (Aluminum) -DR m Hi-Rise Sym. DIN (Aluminum) -DR m Angled Hi-Rise Sym. DIN (Steel) -DR End Barriers Grey -EBL End Anchors and Retainers -ERL DIN Rail Normal Duty -EAJ DIN Rail Heavy Duty -EAHJ Jumpers Plug-in Center Jumper -Pole -CJK- Plug-in Center Jumper -Pole -CJK- Plug-in Center Jumper -Pole -CJK- Plug-in Center Jumper -Pole -CJK- Plug-in Center Jumper -Pole -CJK- Plug-in Center Jumper -Pole -CJK- Plug-in Center Jumper -Pole -CJK- Plug-in Center Jumper -Pole -CJK- Plug-in Center Jumper -Pole -CJK- Plug-in Center Jumper -Pole -CJK- Other Accessories Reducing Sleeves -PSL- (.. mm) White Reducing Sleeves (.. mm) Grey -PSL- Reducing Sleeves (.. mm) Dark Grey -PSL- Test Plug -TP Test Plug (Stackable) -TPL Electrical Warning Plate -EWPL Marking Systems Snap-In Marker Cards -MX (/card) Snap-In Marker Cards -MX (/card)." (. mm) Publication A-CAA-EN-P -

41 Bulletin Spring-Clamp Connection Terminal Blocks Plug-In Style Blocks & Analog Loop Control Block Dimensions are not intended to be used for manufacturing purposes. Note: Height dimension is measured from top of rail to top of terminal block. -." (. mm) -LP -LDGP -LDAG." (. mm)." (. mm) Single circuit plug-in component block for a variety of components." ( mm)." ( mm)." (. mm) Terminal block with slot for plug-in component, feed-through circuit and ground connection." ( mm)." ( mm)." (. mm) Analog Loop Control Terminal Block with Feed-Through Circuits and Ground Connection Certifications CSA IEC CSA IEC CSA IEC Voltage Rating V V V V V V Maximum Current A A A A A A Wire Range (Rated Cross Section) # mm #. mm #. mm Wire Strip Length. in. ( mm). in. ( mm). in. ( mm) Density pcs/ft ( pcs/m) pcs/ft ( pcs/m) pcs/ft ( pcs/m) Housing Temperature Range - + F (- + C) - + F (- + C) - + F (- + C) Terminal Blocks Pkg Qty. Pkg Qty. Pkg Qty. Color Grey -LP -LDGP -LDAG Accessories Pkg Qty. Pkg Qty. Pkg Qty. Mounting Rails m Symmetrical DIN (Steel) -DR -DR -DR m Symmetrical DIN (Aluminum) -DR -DR -DR m Hi-Rise Symmetrical DIN (Aluminum) -DR -DR -DR m Angled Hi-Rise Sym. DIN (Steel) -DR -DR -DR End Barrier -EBL -EBLDAG -EBLDAG End Anchors and Retainers -ERL -ERL -ERL DIN Rail Normal Duty -EAJ -EAJ -EAJ DIN Rail Heavy Duty -EAHJ -EAHJ -EAHJ Jumpers Plug-In Center Jumper -pole -CJK- -CJLJ- -CJLJ- Plug-In Center Jumper -pole -CJK- -CJLJ- -CJLJ- Plug-In Center Jumper -pole -CJK- -CJLJ- -CJLJ- Plug-In Center Jumper -pole -CJK- -CJLJ- -CJLJ- Plug-In Center Jumper -pole -CJK- -CJLJ- -CJLJ- Plug-In Center Jumper -pole -CJK- -CJLJ- -CJLJ- Plug-In Center Jumper -pole -CJK- -CJLJ- -CJLJ- Plug-In Center Jumper -pole -CJK- -CJLJ- -CJLJ- Plug-In Center Jumper -pole -CJK- -CJLJ- -CJLJ- Plug-In Center Jumper -pole -CJK- -CJLJ- -CJLJ- Other Accessories Disconnect Plug -DPL -DPL Component Plug -CPL -CPL Fuse Plug Without Blown Fuse Indicator -FPK -FPK V Blown Fuse Indicator -FPK - FPK V Blown Fuse Indicator -FPK - FPK V Blown Fuse Indicator -FPK - FPK V Blown Fuse Indicator -FPK - FPK Reducing Sleeves (.. mm) White -PSL- Reducing Sleeves (.. mm) Grey -PSL- Reducing Sleeves (.. mm) Dark Grey -PSL- Test Plug -TPL -TP Electrical Warning Plate -EWPL Marking Systems Snap-In Marker Cards -MX (/card) -MX (/card) -MX (/card) Snap-In Marker Cards -MX (/card) -MX (/card) -MX (/card) When using -LDGP with a fuse plug, a center jumper cannot be used on the top level. The only jumper option to use in combination with a fuse plug is a -pole side jumper: -SJLM-. Publication A-CAA-EN-P

42 Bulletin Spring-Clamp Connection Terminal Blocks Flexible Plug-In Connection Blocks Dimensions are not intended to be used for manufacturing purposes. Note: Height dimension is measured from top of rail to top of terminal block.." (. mm) -LP -LTP -LQP." ( mm)." (. mm) Single circuit terminal block with fixed and plug-in connection. Plug-in connectors can be individual or grouped configurations.." (. mm)." (. mm)." (. mm) Single circuit terminal block with fixed and plug-in connection. Plug-in connectors can be individual or grouped configurations.." (. mm)." ( mm)." (. mm) Single circuit terminal block with fixed and plug-in connections. Plug-in connectors can be individual or grouped configurations. Certifications CSA IEC CSA IEC CSA IEC Voltage Rating V V V V V V Maximum Current A A A A A A Limited Rating - Voltage V V V - Limited Rating - Current A A A Wire Range (Rated Cross Section) # # # mm mm mm Wire Strip Length. in. ( mm). in. ( mm). in. ( mm) Density pcs/ft ( pcs/m) pcs/ft ( pcs/m) pcs/ft ( pcs/m) Housing Temperature Range + F ( + C) + F ( + C) + F ( + C) Terminal Blocks Pkg Qty. Pkg Qty. Pkg Qty. Color Grey -LP -LTP -LQP Accessories Pkg Qty. Pkg Qty. Pkg Qty. Mounting Rails m Symmetrical DIN (Steel) -DR -DR -DR m Symmetrical DIN (Aluminum) -DR -DR -DR m Hi-Rise Symmetrical DIN (Aluminum) -DR -DR -DR m Angled Hi-Rise Sym. DIN (Steel) -DR -DR -DR End Barrier Grey -EBLQP -EBLTP -EBLQP Yellow -EBLP-Y -EBLTP-Y - - End Anchors -ERL -ERL -ERL DIN Rail Normal Duty -EAJ -EAJ -EAJ DIN Rail Heavy Duty -EAHJ -EAHJ -EAHJ Jumpers Plug-In Center Jumper -pole -CJLJ- -CJLJ- -CJLJ- Plug-In Center Jumper -pole -CJLJ- -CJLJ- -CJLJ- Plug-In Center Jumper -pole -CJLJ- -CJLJ- -CJLJ- Plug-In Center Jumper -pole -CJLJ- -CJLJ- -CJLJ- Plug-In Center Jumper -pole -CJLJ- -CJLJ- -CJLJ- Plug-In Center Jumper -pole -CJLJ- -CJLJ- -CJLJ- Plug-In Center Jumper -pole -CJLJ- -CJLJ- -CJLJ- Plug-In Center Jumper -pole -CJLJ- -CJLJ- -CJLJ- Plug-In Center Jumper -pole -CJLJ- -CJLJ- -CJLJ- Plug-In Center Jumper -pole -CJLJ- -CJLJ- -CJLJ- Other Accessories Test Adapter -TPLP -TPLP -TPLP Individual Plug-in Connector Ganged Connector Start Plug Ganged Connector Middle Plug Ganged Connector End Plug Plug-in Component Accessories Locking Element - Yellow Grey -STP -STP -STP Green -STP-G -STP-G -STP-G Grey -SBSTP -SBSTP -SBSTP Grey -GSTP -GSTP -GSTP Grey -EBSTP -EBSTP -EBSTP -STPLE -STPLE -STPLE Coding Element - Yellow -STPCE -STPCE -STPCE Strain Relief - Yellow -STPSR -STPSR -STPSR Marking Systems Snap-In Marker Cards -MRX (/card) -MRX (/card) -MRX (/card) Snap-In Marker Cards -MX (/card) -MX (/card) -MX (/card) Terminal Blocks contain dual UL/CSA listings and can be used at V with a A rating or V with a A rating. For ganged configurations greater than, use multiple -GSTP plug-in blocks. Publication A-CAA-EN-P -

43 Bulletin Spring-Clamp Connection Terminal Blocks Plug-in Connection Blocks -LDP -LGP -LGTP Dimensions are not intended to be used for manufacturing purposes. Note: Height dimension is measured from top of rail to top of terminal block.." ( mm)." (. mm)." (. mm)." (. mm)." ( mm)." (. mm)." (. mm)." (. mm)." (. mm) Two- circuit terminal block with fixed and plug-in connection. Plug-in connectors can be individual or grouped configurations. Single circuit grounding terminal block with fixed and plug-in connection. Single circuit grounding terminal block with fixed and plug-in connection. Certifications CSA IEC CSA IEC CSA IEC Voltage Rating V V Maximum Current A A Grounding Grounding Limited Rating - Voltage V Limited Rating - Current A Wire Range (Rated Cross Section) #... mm #... mm # Wire Strip Length. in. ( mm). in. ( mm). in. ( mm) Density pcs/ft ( pcs/m) pcs/ft ( pcs/m) pcs/ft ( pcs/m) Housing Temperature Range + F ( + C) + F ( + C) + F ( + C) Terminal Blocks Pkg Qty. Pkg Qty. Pkg Qty. Color Grey -LDP Green/ Yellow -LGP -LGTP... mm Accessories Pkg Qty. Pkg Qty. Pkg Qty. Mounting Rails m Symmetrical DIN (Steel) -DR -DR -DR m Symmetrical DIN (Aluminum) -DR -DR -DR m Hi-Rise Symmetrical DIN (Aluminum) -DR -DR -DR m Angled Hi-Rise Sym. DIN (Steel) -DR -DR -DR End Barrier Grey -EBLDP Yellow -EBLP-Y -EBLP-Y End Anchors -ERL -ERL -ERL DIN Rail Normal Duty -EAJ -EAJ -EAJ DIN Rail Heavy Duty -EAHJ -EAHJ -EAHJ Jumpers Plug-In Center Jumper -pole -CJLJ- Plug-In Center Jumper -pole -CJLJ- Plug-In Center Jumper -pole -CJLJ- Plug-In Center Jumper -pole -CJLJ- Plug-In Center Jumper -pole -CJLJ- Plug-In Center Jumper -pole -CJLJ- Plug-In Center Jumper -pole -CJLJ- Plug-In Center Jumper -pole -CJLJ- Plug-In Center Jumper -pole -CJLJ- Plug-In Center Jumper -pole -CJLJ- Other Accessories Test Adapter -TPLP Individual Plug-in Connector Ganged Connector Start Plug Ganged Connector Middle Plug Ganged Connector End Plug Plug-in Component Accessories Locking Element - Yellow Grey -STP Green -STP-G -STP-G -STP-G Grey -SBSTP Grey -GSTP Grey -EBSTP -STPLE -STPLE -STPLE Coding Element - Yellow -STPCE -STPCE -STPCE Strain Relief - Yellow -STPSR -STPSR -STPSR Terminal Blocks contain dual UL/CSA listings and can be used at V with a A rating or V with a A rating. - Publication A-CAA-EN-P

44 Bulletin Spring-Clamp Connection Terminal Blocks Internal Component Blocks Dimensions are not intended to be used for manufacturing purposes. Note: Height dimension is measured from top of rail to top of terminal block.." (. mm) -LDDF -LDDR -LDSS." ( mm)." (. mm) Two-level terminal block with an IN diode in forward bias between the levels.." (. mm)." ( mm)." (. mm) Two-level terminal block with an IN diode in reverse bias between the levels.." (. mm)." ( mm)." (. mm) Two level terminal block with an MOV between the levels. Certifications CSA IEC CSA IEC CSA IEC Voltage Rating V V V V V V Maximum Current A A A A A A V Component Current/Wattage Rating A A A A A Wire Range (Rated Cross Section) # mm # mm # Wire Strip Length. in. ( mm). in. ( mm). in. ( mm) Density pcs/ft ( pcs/m) pcs/ft ( pcs/m) pcs/ft ( pcs/m) Housing Temperature Range - + F (- + C) - + F (- + C) + F ( + C) V Terminal Blocks Pkg Qty. Pkg Qty. Pkg Qty. Color Black -LDDF -LDDR -LDSS Accessories Pkg Qty. Pkg Qty. Pkg Qty. Mounting Rails m Symmetrical DIN (Steel) -DR -DR -DR m Symmetrical DIN (Aluminum) -DR -DR -DR m Hi-Rise Symmetrical DIN (Aluminum) -DR -DR -DR m Angled Hi-Rise Sym. DIN (Steel) -DR -DR -DR End Barrier Grey -EBLD -EBLD -EBLD End Anchors and Retainers -ERL -ERL -ERL DIN Rail Normal Duty -EAJ -EAJ -EAJ DIN Rail Heavy Duty -EAHJ -EAHJ -EAHJ Jumpers Plug-in Center Jumper -pole -CJK- -CJK- -CJK- Plug-in Center Jumper -pole -CJK- -CJK- -CJK- Plug-in Center Jumper -pole -CJK- -CJK- -CJK- Plug-in Center Jumper -pole -CJK- -CJK- -CJK- Plug-in Center Jumper -pole -CJK- -CJK- -CJK- Plug-in Center Jumper -pole -CJK- -CJK- -CJK- Plug-in Center Jumper -pole -CJK- -CJK- -CJK- Plug-in Center Jumper -pole -CJK- -CJK- -CJK- Plug-in Center Jumper -pole -CJK- -CJK- -CJK- Other Accessories Test Plug -TP -TP -TP Marking Systems Snap-In Marker Cards -MX (/card) -MX (/card) -MX (/card) Snap-In Marker Cards -MX (/card) -MX (/card) -MX (/card) For component specifications, see page - mm Publication A-CAA-EN-P -

45 Bulletin Spring-Clamp Connection Terminal Blocks -Level Neutral Disconnect and Installations Dimensions are not intended to be used for manufacturing purposes. Note: Height dimension is measured from top of rail to top of terminal block.. ( mm) -LDGND -LDN -LDGN. ( mm). (. mm) -Level terminal block with neutral disconnect and ground connection. ( mm). ( mm). (. mm) -Level feed-through terminal block for installation applications. ( mm). ( mm). (. mm) -Level terminal block with feedthrough and ground connection Certifications CSA IEC CSA IEC CSA IEC Voltage Rating V V V Maximum Current A A A V A V V V V V A A A A A Wire Range (Rated Cross Section) #. mm #. mm #. mm Wire Strip Length. in. ( mm). in. ( mm). in. ( mm) Density pcs/ft ( pcs/m) pcs/ft ( pcs/m) per ft/ per meter Housing Temperature Range F (-...+ C) F (-...+ C) F (-...+ C) Short-Circuit Current Rating See page - Terminal Blocks Pkg Qty. Pkg Qty. Pkg Qty. Color: Grey -LDGND -LDN -LDGN Accessories Pkg Qty. Pkg Qty. Pkg Qty. Mounting Rails: m Symmetrical DIN (Steel) -DR -DR -DR m Symmetrical DIN (Aluminum) -DR -DR -DR m Hi-Rise Sym. DIN (Aluminum) -DR -DR -DR m Angled Hi-Rise Sym. DIN (Steel) -DR -DR -DR End Barriers/ Busbar Support Plates End Anchors and Retainers: Grey -BSPJLDN -BSPJLDN -BSPJLDN Blue -BSPJLDN-B -BSPJLDN-B -BSPJLDN-B -ERL -ERL -ERL End Anchor Normal Duty -EAJ -EAJ -EAJ End Anchor Heavy Duty -EAHJ -EAHJ -EAHJ Plug-in Center Jumper -Pole -CJLJ- -CJLJ- -CJLJ- Plug-in Center Jumper -Pole -CJLJ- -CJLJ- -CJLJ- Plug-in Center Jumper -Pole -CJLJ- -CJLJ- -CJLJ- Plug-in Center Jumper -Pole -CJLJ- -CJLJ- -CJLJ- Other Accessories: Partition Plate Neutral Connection Block ( mm) Blue Neutral Connection Bloc ( mm) Blue - JNC-B - JNC-B Neutral Bus Bar ( m) -NBB-M Marking Systems: Snap-in Marker Cards -MX (/card) -MX (/card) -MX (/card) These terminals mount on -NBB-M Neutral Busbar. They can accept -MX snap-in markers. - Publication A-CAA-EN-P

46 Bulletin Spring-Clamp Connection Terminal Blocks Fuse Blocks Dimensions are not intended to be used for manufacturing purposes. Note: Height dimension is measured from top of rail to top of terminal block.." (. mm) -RFB." ( mm)." ( mm) Single-circuit fuse terminal block with or without blown fuse indicator." (. mm) -RAFB." ( mm)." ( mm) Single-circuit fuse terminal block with or without blown fuse indicator Certifications cur IEC cur IEC Maximum Current A A A A A A Wire Range (Rated Cross Section) # #. mm # #. mm RFB/RAFB V V V V Voltage Rating RFB/RAFB V V RFB/RAFB V AC V AC RFB/RAFB Non-indicating Non-indicating Indicator Type RFB/RAFB LED LED RFB/RAFB Neon Neon RFB/RAFB Leakage Current RFB/RAFB V V RFB/RAFB V V Fuse Size (Not Supplied) x mm / x -/ in. Wire Strip Length. in. ( mm). in. ( mm) Density pcs/ft ( pcs/m) pcs/ft ( pcs/m) Insulation Temperature Range - + F (- + C) - + F (- + C) Terminal Blocks Pkg Qty. Pkg Qty. Color Black (Non-Indicating) -RFB -RAFB Black ( V LED) -RFB -RAFB Black ( V Neon) -RFB -RAFB Accessories Pkg Qty. Pkg Qty. Mounting Rails m Symmetrical DIN (Steel) -DR -DR m Symmetrical DIN (Aluminum) -DR -DR m Hi-Rise Sym. DIN (Aluminum) -DR -DR m Angled Hi-Rise Sym. DIN (Steel) -DR -DR End Barrier Not Required Not Required End Retainers/Anchors -ERL -ERL DIN Rail Heavy Duty -EAHJ -EAHJ Plug-in Center Jumper, -Pole -CJR- Plug-in Center Jumper, -Pole -CJR- Plug-in Center Jumper, -Pole -CJR- Plug-in Center Jumper, -Pole -CJR- Plug-in Center Jumper, -Pole -CJR- Plug-in Center Jumper, -Pole -CJR- -CJRA- Plug-in Center Jumper, -Pole -CJR- -CJRA- Plug-in Center Jumper, -Pole -CJR- -CJRA- Plug-in Center Jumper, -Pole -CJR- -CJRA- Center Jumper Link -CJRL -CJRL Marking Systems Snap-in Marker for Block -MSX (/card) -MSX (/card) Snap-in Marker for Handle -MSX (/card) -MSX (/card) IEC standards for x mm fuses do not include ratings above. A. Publication A-CAA-EN-P -

47 Bulletin Spring-Clamp Connection Terminal Blocks Single-Circuit Automotive Fuse Block -LAFB Dimensions are not intended to be used for manufacturing purposes. Note: Height dimension is measured from top of rail to top of terminal block.." ( mm)." (. mm)." ( mm) Single-circuit automotive style fuse terminal block with or without LED blown fuse indication Certifications CSA IEC Voltage Rating -LAFB V V -LAFB V Maximum Current A A A Wire Range (Rated Cross Section) # #. mm Wire Strip Length. in. ( mm) Density pecs/ft ( pcs/m) Housing Temperature Range - + F (- + C) Terminal Blocks Pkg Qty. Black (without blown fuse indication) -LAFB Color Black (with blown fuse indication) -LAFB Accessories Pkg Qty. Mounting Rails m Symmetrical DIN (Steel) -DR m Symmetrical DIN (Aluminum) -DR m Hi-Rise Sym. DIN (Aluminum) -DR m Angled Hi-Rise Sym. DIN (Steel) -DR End Barrier Black -EBLAFB End Anchors -ERL DIN Rail - Normal Duty -EAJ Din Rail - Heavy Duty -EAHJ Jumpers Plug-in Center Jumper -Pole -CJL- Plug-in Center Jumper -Pole -CJL- Plug-in Center Jumper -Pole -CJL- Plug-in Center Jumper -Pole -CJL- Test Adapter -TPL Marking Systems Snap-in Marker Cards -MX (/card) Snap-In Marker Cards -MX (/card) - Publication A-CAA-EN-P

48 Bulletin Spring-Clamp Connection Terminal Blocks Plug-in Connection Blocks Dimensions are not intended to be used for manufacturing purposes. Note: Height dimension is measured from top of rail to top of terminal block.." (. mm) -LC." (. mm)." ( mm) Feed-through terminal block with plug in comb connection on one side.." (. mm) -LDC." (. mm)." ( mm) Two Circuit terminal block with plug in comb connection on one side of each circuit Certifications CSA IEC CSA IEC Voltage Rating V V V V Maximum Current A A A A Wire Range (Rated Cross Section) #. mm #. mm Wire Strip Length. in. ( mm). in. ( mm) Density pcs/ft ( pcs/m) pcs/ft ( pcs/m) Housing Temperature Range + F ( + C) + F ( + C) Terminal Blocks Pkg Qty. Pkg Qty. Color Grey -LC -LDC Plug Connection Strips Pkg Qty. Pkg Qty. Color/Quantity Black/-Pole -QP- -QP- Black/-Pole -QP- -QP- Black/-Pole -QP- -QP- Black/-Pole -QP- -QP- Black/-Pole -QP- -QP- Black/-Pole -QP- -QP- Black/-Pole -QP- -QP- Black/-Pole -QP- -QP- Black/-Pole -QP- -QP- Black/-Pole -QP- -QP- Black/-Pole -QP- -QP- Accessories Pkg Qty. Pkg Qty. Mounting Rails m Symmetrical DIN (Steel) -DR -DR m Symmetrical DIN (Aluminum) -DR -DR m Hi-Rise Sym. DIN (Aluminum) -DR -DR m Angled Hi-Rise Sym. DIN (Steel) -DR -DR End Barriers Grey -EBLC -EBLDC End Anchors and Retainers: -ERL -ERL DIN Rail Normal Duty -EAJ -EAJ DIN Rail Heavy Duty -EAHJ -EAHJ Jumpers Plug-in Center Jumper -Pole -CJLJ- -CJLJ- Plug-in Center Jumper -Pole -CJLJ- -CJLJ- Plug-in Center Jumper -Pole -CJLJ- -CJLJ- Plug-in Center Jumper -Pole -CJLJ- -CJLJ- Plug-in Center Jumper -Pole -CJLJ- -CJLJ- Plug-in Center Jumper -Pole -CJLJ- -CJLJ- Plug-in Center Jumper -Pole -CJLJ- -CJLJ- Plug-in Center Jumper -Pole -CJLJ- -CJLJ- Plug-in Center Jumper -Pole -CJLJ- -CJLJ- Plug-in Center Jumper -Pole -CJLJ- -CJLJ- Other Accessories Group Marking Carrier -GM -GM Marking Systems Snap-In Marker Cards -MX (/card) -MX (/card) Snap-In Marker Cards -MX (/card) -MX (/card) Hinged Marker Card -MHX (/card) Publication A-CAA-EN-P -

49 Bulletin Spring-Clamp Connection Terminal Blocks Short-Circuit Current Ratings Short-Circuit Current Ratings Fuse Ratings -L -LQ -LT -LD -LQS -LMJ -LMJG -LKD -LP -LGT -LGQ -LG -LDC -LDGC -LDG -LC -LDC -LDGP -LDGND -LDGN -LDN -LDP -LDQP -LGP -LGTP -LTP -LDGFB -L -LQ -LT -LD -LDC -LG -LGT -LGQ -LDDFX -L -LT -LG -LGT Wire Cu [] Overcurrent Protection Fuse Required Class/Max. Amp Rating Maximum Line Load J T RK RK G CC Voltage SCCR, RMS SYM [A],,,, -LAFB, -L -LG, -L -LG, -L -LG, - Preferred availability cat. nos. are bold. Publication A-CAA-EN-P

50 Bulletin IEC Terminal Block Accessories Mounting Rails Mounting rails allow many blocks to be fastened in a panel with only a few screws to anchor the rail to the panel. Mounting rails allow easy installation and removal of a block in a row. Description Pkg Qty. Dimensions -DR Symmetrical Rail mm x. mm. ft ( m) long Zinc-Plated Clear Chromated Steel EN DIN # -DR -DR -DR Same as -DR, but length = m Heavy Duty Symmetrical Rail mm x mm. ft ( m) long Zinc-Plated Clear Chromated Steel EN DIN # Mini mm x. mm Rail. ft ( m) long Zinc-Plated Clear Chromated Steel EN -DR DIN # Symmetrical Rail mm x. mm. ft ( m) long Copper-Free Aluminum EN For Bul. Terminal Blocks Only DIN # -DR Symmetrical Rail mm x. mm. in. (. mm) high. ft ( m) long Copper-Free Aluminum For Bul. Terminal Blocks Only DIN # -DR Symmetrical Rail mm x. mm. in. (. mm) high. ft ( m) long Angled Zinc-Plated, Chromated Steel DIN # -DR Symmetrical Rail mm x mm. ft ( m) long Copper EN DIN # -DR Symmetrical Rail mm x mm. ft ( m) long Zinc-Plated Clear Chromated Steel EN !! Detail"A DIN # See"Detail"A Dimensions shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.. x. in. (. x. mm) slotted mounting holes every in. (. mm) starting. in. (. mm) from end. Dimensions in millimeters. Publication A-CAA-EN-P -

51 Bulletin IEC Terminal Block Accessories End Barriers End Barriers End barriers are required to provide the necessary insulation for the last terminal block in a group. Dimensions Width x Length x Height For Use With Color Pkg Qty.. x. x. in. ( x. x. mm). x. x. in. ( x. x mm). x. x. in. ( x. x mm). x. x. in. ( x. x. mm). x. x. in. ( x. x. mm). x. x. in. ( x. x mm). x. x. in. (. x x mm). x. x. in. ( x. x mm). x. x. in. (. X. x.). x. x. in. ( x. x mm). x. x. in. ( x. x mm). x. x. in. ( x. x mm). x. x. in. ( x. x mm). x. x. in. ( x. x mm). x. x. in. ( x. x. mm). x. x. in. ( x. x. mm) -L, LG -LT, LGT -LQ, LGQ -L, LG, LKD, LP -LT, LGT -LQ, LQS, LGQ -LP, -LGP -LTP, -LGTP Grey -EBL Blue -EBL-B Yellow -EBL-Y Grey -EBLT Blue -EBLT-B Yellow -EBLT-Y Grey -EBLQ Blue -EBLQ-B Yellow -EBLQ-Y Grey -EBL Blue -EBL-B Yellow -EBL-Y Grey -EBLT Blue -EBLT-B Yellow -EBLT-Y Grey -EBLQ Blue -EBLQ-B Yellow -EBLQ-Y Grey -EBLP Yellow -EBLP-Y Grey -EBLTP Yellow -EBLTP-Y -LQP Grey -EBLQP -LDP Grey -EBLDP -L, LG -LT, LGT -LQ, LGQ -L, LG -LT, LGT -L, LG -L, LG Grey -EBL Blue -EBL-B Yellow -EBL-Y Grey -EBLT Blue -EBLT-B Yellow -EBLT-Y Grey -EBLQ Blue -EBLQ-B Yellow -EBLQ-Y Grey -EBL Blue -EBL-B Yellow -EBL-Y Grey -EBLT Blue -EBLT-B Yellow -EBLT-Y Grey -EBL Blue -EBL-B Yellow -EBL-Y Grey -EBL Blue -EBL-B Yellow -EBL-Y -LAFB Black -EBLAFB. x. x. in. ( x. x mm). x. x. in. ( x. x. mm). x. x. in. ( x x mm) -LD, LDG, LDC, LDGC -LD, LDC, LDG, LDGC -LD, LDC, LDG, LDGC, LDDF, LDDR, LDRB, LDSS Grey -EBLD Blue -EBLD-B Yellow -EBLD-Y Grey -EBLD Blue -EBLD-B Yellow -EBLD-Y Grey -EBLD Blue -EBLD-B Yellow -EBLD-Y - Preferred availability cat. nos. are bold. Publication A-CAA-EN-P

52 Bulletin IEC Terminal Block Accessories End Barriers End Barriers, continued Dimensions Width x Length x Height For Use With Color Pkg Qty.. x. x. in. Grey -EBLMP -LMP, LMPQ (. x. x. mm) Blue -EBLMP-B. x. x. in. (. x. x. mm). x. x. in. (. x. x mm) End anchors and end retainers mount at both ends of a group of terminal blocks to add rigidity to the terminal assembly and prevent sliding along the rails. Photo -LM, LMQ, LMG, LMPE, LMPQE Dimensions Width x Length x Height. x. x. in. ( x x mm) -LMJ, LMJG Tightening Torque Markers For Use With Color Pkg Qty.. lb in (. N m) Grey -EBLM Blue -EBLM-B Yellow -EBLM-Y Grey -EBLMJ Blue -EBLMJ-B Yellow -EBLMJ-Y. x. x. in. (. x x. mm) -LTF -EBLTF. x. x. in. ( x. x mm) -LS-, LS-L, LSG- -EBLS-. x. x. in. -LS-, LS-L, LSG- -EBLS- ( x. x mm) Grey. x. x. in. -LDAG, LDGP -EBLDAG (. x x mm). x. x. in. (. x. x mm) -LC -EBLC. x. x. in. (. x. x mm) -LDC -EBLDC -LDGND, LDN, LDGN Grey -BSPJLDN -LDGND, LDN, LDGN Blue - BSPJLDN-B End Anchor/End Retainers -MX -MX -DR, -DR, -DR, -DR, -DR, -DR, -DR, -DR Grey -EAJ. x. x. in. (. x x mm). lb in. (. N m) -MX -MX -DR, -DR, -DR, -DR, -DR, -DR, -DR, -DR Grey -EAHJ. x. x. in. ( x x mm). lb in. (. N m) -MX -DR Grey -EAJ. x. x. in. ( x. x. mm) -MX -MX -DR, -DR, -DR, -DR, -DR, -DR, -DR, -DR Grey -ERL. x. x. in. ( x. x mm) -MX -MX -DR Grey -ERL Preferred availability cat. nos. are bold. Publication A-CAA-EN-P -

53 Bulletin IEC Terminal Block Accessories Partition and Separation Plates Partition Plates and Separation Plates Partition plates allow visual and electrical separation of terminal groups and provide the necessary electrical spacing between adjacent insulated jumpers or between exposed ends of cut jumpers. Separation plates consist of flexible thermoplastic material and are used between terminal blocks to isolate adjacent center jumpers both visually and electrically. Dimensions Width x Length x Height For Use With Color. x. x. in. ( x x mm). x. x. in. (. x. x. mm). x. x. in. ( x x. mm). x. x. in. (. x x. mm). x. x. in. (. x x mm). x. x. in. (. x x mm). x. x. in. (. x. x. mm). x. x. in. (. x x mm). x. x. in. (. x. x. mm) Partition Plates Pkg Qty. -JD, JDC, JDF, JDDF, JDDR, JDRC, JDSS Grey -PPJD -JDP, JDGP Beige -PPJDP -WM, WM, WMG, WMG Grey -PPM -WMD Grey -PPMD -W, W, WG Grey -PP -W, W, WS, WTW, WG, WGS, WGS Grey -PP -WTF, WTS Beige -PPTS -J, J, J, J, JQ, JTW, JF, JGQ, JG, JGTW, JKD, JKDTP, JP, JPTP, JTC Separation Plates Grey -EBJ Blue -EBJ-B Yellow -EBJ-Y -W, W Beige -SP All -FPK Fuse Plugs Beige -SPJ - Publication A-CAA-EN-P

54 Bulletin IEC Terminal Block Accessories Jumpers Jumpers use the terminal block wire openings. Multi-pole jumpers can be cut into a smaller number of poles. Jumpers carry % of rated terminal block current. The back of IEC style jumpers are insulated with plastic. An adjacent partition plate provides the necessary electrical spacings between adjacent jumpers or between exposed ends of cut jumpers. Center Jumpers Screw Type These center jumpers are insulated and are available in - -pole configurations. They mount with screws into the screw type terminal blocks. Note: The following rules apply when going across different potentials with jumpers cut out: Always de-rate to V Always use a partition plate where a cut jumper strip may leave a live end exposed Center Jumpers Screwless Type These center jumpers are insulated and are available in - -pole configurations. They mount without screws into the both Spring-Clamp terminal blocks and some screw terminal blocks. Note: When using multiple screwless jumpers in -J, -JQ, or -J terminal blocks, the following rules apply when going across different potentials with jumpers cut out: When using all channels, or side-by-side channels, de-rate to V When using outside channels (leaving the center channel open), de-rate to V Always use a partition plate where a cut jumper strip may leave a live end exposed Center Jumper Covers Center jumper covers can be used as an extruded marking surface for circuit identification. Center Jumper Configuration Plates Photo For Use With Color Center Jumper Spacer Plate -L to -LQ, L -L to -LQ, L Center Jumper Connector Plate Pkg Qty. Grey -LJS -L to -LT Grey -LJC Step-Down Distribution Jumpers Photo For Use With Pkg Qty. -J to -J or J -CJJSD -J to -J or J -CJJSD -J to -J -CJJSD -J to -J -CJJSD Publication A-CAA-EN-P -

55 Bulletin IEC Terminal Block Accessories Jumpers Screw Type Center Jumpers For Use With -J, JD, JDG, JQ, JTW, JF, JDF -J, JM -J -J -J -J -J -J -WM -W, WM, WR, WTF, WTS -WR Pkg Qty. -CJJ- -CJJ- -CJJ- -CJJ- -CJJ- -CJJ- -CJJ- -CJJ- -CJJ- -CJJ- -CJJ- -CJJ- -CJJ- -CJJ- -CJJ- -CJJ- -CJJ- -CJJ- -CJJ- -CJJ- -CJJ- -CJJ- -CJJ- -CJJ- -CJJ- -CJJ- -CJJ- -CJJ- -CJJ- -CJJ- -CJM- -CJM- -CJM- -CJM- -CJM- -CJL (Link) -CJD- -CJD- -CJD- -CJD- -CJD- -CJD- Note: Notching out one or more jumper poles, with the notched jumpers going across different potentials, will require de-rating to V. For Use With -WM Pkg Qty. -CJD- -CJD- -CJD- -CJD- -CJD- -CJD- -WM, WTW -CJLD (Link) -W -WTF, WTS -W, WTW -CJ- -CJ- -CJ- -CJCW (CJ Cover) -CJT- -CJT- -CJT- -CJT- -CJT- -CJT- -CJ- -CJ- -CJ- -CJ- -CJ- -CJ- -W -CJL (Link) -W, W, W -W -CJCW (CJ Cover) -CJ- -CJ- -CJ- -CJ- -CJ- -CJ- -W -CJL (Link) -W -CJ- -CJ- -CJ- -CJ- -CJ- -CJ- -W -CJL (Link) -WS -CJS- -CJS- -CJS- -CJS- -CJS- May only be used as a marking surface. May not be installed over center jumper. - Publication A-CAA-EN-P

56 Screwless Center Jumpers For Use With Color Pkg Qty. -L, LT, LQ, LD, LDC -LM, LC, LDC, LDAG, LDGP, JKD, JP, J, JTW (see Note) Yellow -CJL- -CJL- -CJL- -CJL- -CJL- Yellow -CJLJ- Red -CJLJ--R Blue -CJLJ--B Black -CJLJ--BL Yellow -CJLJ- Red -CJLJ--R Blue -CJLJ--B Black -CJLJ--BL Yellow -CJLJ- -CJLJ- -CJLJ- -CJLJ- -CJLJ- -CJLJ- -CJLJ- Red -CJLJ--R Blue -CJLJ--B Black -CJLJ--BL White -CJLJ--W Yellow -CJLJ- Red -CJLJ--R Blue -CJLJ--B Black -CJLJ--BL White -CJLJ--W For Use With Pkg Qty. -RFB -RAFB -CJR- -CJR- -CJR- -CJR- -CJR- -CJR- -CJR- -CJR- -CJR- -CJRA- -CJRA- -CJRA- -CJRA- Bulletin IEC Terminal Block Accessories For Use With Color Pkg Qty. -J, JM (see Note) -L, LT, LD Jumpers Yellow -CJLJ- Red -CJLJ--R Blue -CJLJ--B Black -CJLJ--BL Yellow -CJLJ- Red -CJLJ--R Blue -CJLJ--B Black -CJLJ--BL Yellow -CJLJ- Yellow -CJLJ- Red -CJLJ--R Blue -CJLJ--B Black -CJLJ--BL Yellow -CJLJ- Red -CJLJ--R Blue -CJLJ--B Black -CJLJ--BL Yellow -CJL- -CJL- -CJL- -CJL- -L Yellow -CJL- -L Yellow -CJL- -L Yellow -CJL- -L, LT, LQ, LP, LD, LDC, LKD, LTF, LS, LD -L, LT, LQ, LDDF, LDDR, LDSS, LD, LDC, LD Yellow Yellow -CJK- -CJK- -CJK- -CJK- -CJK- -CJK- -CJK- -CJK- -CJK- -CJK- -CJK- -CJK- -CJK- -CJK- -CJK- -CJK- -CJK- -CJK- -CJK- -CJK- Preferred availability cat. nos. are bold. Publication A-CAA-EN-P -

57 Bulletin IEC Terminal Block Accessories Jumpers Side Jumpers For Use With Two-Level Jumper Pkg Qty. -WM, W -N -H, H, H, H -N -SJS -W, WR -SJ- -JD, JDC, JDF, JDG, JDDF, JDDR, JDSS, JDGP -JD, JDC, JDF, JDG, JDDF, JDDR, JDSS, JDGP -JD, JDC, JDF, JDG, JDDF, JDDR, JDSS, JDGP -JD, JDC, JDF, JDG, JDDF, JDDR, JDSS, JDGP -SJA- -SJA- -SJB- -SJB- -WM, W, WTW -SJ- -JTM -SJA- -W -SJ- -JDFB, JDGFB -SJA- -JDFB, JDGFB -SJA- -JDFB, JDGFB -SJA- -LMP, LMPQ, LMJ, LM, LMQ, LMPE, LMPQE -SJLM- -WMD -SJMD- -WFB, WFB, WFB -SJFB- -WM -SJM- -WTF, WTS, WTFLP, WTSLP, WTFLP, WTFLN, WTSLN -WTF, WTS, WTFLP, WTSLP, WTFLP, WTFLN, WTSLN -SJT--R -SJT--B Note: Side jumpers carry the same current rating as the terminal block used with it Side jumper insulating sleeve only for use with -N Use jumper on single side of terminal block only Uninsulated For Use With -LTF (Connects Two Levels within a -LTF Terminal Block) Pkg Qty. -CJLD - Publication A-CAA-EN-P

58 Bulletin IEC Terminal Block Accessories General Accessories Plugs and Other Accessories Test plug sockets fit into the center bridge screw hole and allow easy connection of test plugs for circuit testing and troubleshooting. Test Plugs Spring-Clamp Terminal Blocks - -pole Quick Connection Euro style plugs. Operating Instructions Spring-Clamp Terminal Blocks -QCLABEL is an adhesive set of visual operating instructions that is intended for installation on the inside of a panel. It illustrates to maintenance personnel the correct operation of Spring-Clamp terminal blocks. Insulation Stops Spring-Clamp Terminal Blocks Protective insulation stops prevent the insulation on conductors from being introduced into clamp and current bar area. Test Plug Sockets, Test Plugs, Test Plug Adapters, and Test Adapters Sockets Photo Pkg Qty. Test Plug Adapters Photo Pkg Qty. -TA -TA -TAL -TPLP -TPS -TPSL -TPSL Required for testing -J products with Cat. -TP or -TP test plugs. Test Plugs Photo Pkg Qty. -TP Test Plugs (Stackable) Photo Marker cover screws. Markers Pkg Qty. -MX, MX -TPJ -MX, MX -TPJ -MX, MX -TPL -MX, MX -TPL -MX, MX -TPL -MX, MX -TPL -TP -TP -TPCBM -TPCMB Used in conjunction with -TPS or -TPSL test sockets. Used in conjunction with -TPSL socket. Used in conjunction with -JCTB terminal block. Publication A-CAA-EN-P -

59 Bulletin IEC Terminal Block Accessories General Accessories Photo Description For Use With Pkg Qty. Jumper Notching Tool -CJ -T Unused Pin Cover on Connection Blocks Disconnect Plug Plug-In Component Plug Fuse Plug without Blown Fuse Indication Fuse Plug V Blown Fuse Indication Fuse Plug V Blown Fuse Indication Fuse Plug V Blown Fuse Indication Fuse Plug V Blown Fuse Indication -JC, JDC -PCJC -LP, JP, JDP, JDGP, LDR -LP, JP, JDP, JDGP, LDR -LP, JP, JDP, JDGP, LDR -DPL -CPL -FPK -FPK -FPK -FPK -FPK Mini-Block Jumper Insertion Tool -LM -TAL- DIN Rail Adapter Plate for LMP Mini-Blocks -LMP -MFLM -J -JA -J -JA Auxiliary Circuit Tap -J -JA Terminal Block screwdriver with hardened mm diameter blade (Handle made from recycled material) Wire cutting tool designed to attach directly to the shaft of the -N screwdriver Used to trim poles from center jumpers and side jumpers. Used to install -SJLM- in mini blocks. Use x mm fuses and are rated for AC and DC. All mm wide terminal blocks -N -N -KWC - Preferred availability cat. nos. are bold. Publication A-CAA-EN-P

60 Bulletin IEC Terminal Block Accessories General Accessories Plug-In and Sensor Connection Blocks Plug-In Connection Blocks Photo Wire Range # (. mm) For Use With -JC, JDC, LC, LDC Tightening Torque:.. lb in. (.. N m) Pkg Qty. -QP- -QP- -QP- -QP- -QP- -QP- -QP- -QP- -QP- -QP- -QP- DIN Rail Receptacle Convenient A or A power source designed to be installed in panels that will be used in North America and other locations that use the NEMA - socket (V, / Hz). Photo Device Rating Standard Duplex Pkg Qty. A -REC A -REC Ground Fault Circuit Interrupter (GFCI) A -RECG A -RECG Sensor Connection Blocks Photo Wire Range For Use With Color # (. mm) -LS-, LS-L, LSG-, LS-, LS- L, LSG- Pkg. Qty. Brown -LS-BR Blue -LS-B Green -LSG Plug-In Connectors and Accessories for Flexible Configuration Blocks Photo Description Color Pkg. Qty. Individual Plug-in Connectors Standard Grey -STP Grounded Green -STP-G Ganged Connectors Start plug Grey -SBSTP Middle plug Grey -GSTP End plug Grey -EBSTP Electrical Ratings Standard Duplex Ground Fault Circuit Interrupter (GFCI) Certifications UL A, NEMA WD-, NEMA -R UL UL, UL A Amp V Device Rating A Amp V Operating Frequency / Hz Dielectric Voltage Withstands V per UL Withstands V per UL Short-Circuit Current Rating ka ka Environmental Ratings Operating Temperature Range + F ( + C) Storage Temperature Range + F ( + C) Mechanical Ratings Terminal Wire Sizes # # solid or stranded Terminal Torque lb in. (. N m) Markers -MSX Accessories Plug-in block locking element Yellow -STPLE Coding Element for keyed configuration Yellow -STPCE Strain Relief covering w plug-in blocks Yellow -STPSR Publication A-CAA-EN-P -

61 Bulletin IEC Terminal Block Accessories Marking Systems Marking Solutions Marking Solutions from Rockwell Automation enable efficient identification of terminal blocks and other components. The Allen-Bradley ClearMark Printer provides quality printing for highvolume users. The X-Y Plotter allows for flexible marking. Lowvolume marking needs are supported by pre-printed and custom markers. ClearMark Printer and Accessories The ClearMark Printer provides quality printing in an easy-to-use format for high-volume marking needs. Used with Allen-Bradley ClearTools software, customers can create markers with basic numbering to sequences and images. X-Y Plotter and Accessories The flexible marking tool of the Allen-Bradley terminal block product line is the X-Y Plotter. Fast: Less than two minutes to print and set a full card Easy: Integrated feeder for up to marker cards Low-maintenance: Will automatically cycle as needed to keep ink flowing Quality printing: or dpi Color printing: Use spot color printing on white marker cards for visual distinction System Requirements Operating system: Microsoft Windows, XP or Vista Memory: MB RAM Hard drive: MB available space Processor: Pentium III or comparable Graphics: x pixels with colors (ideal x with - bit high color) Description Pkg Qty. ClearMark Printer, V Includes ClearMark Printer, ClearTools -PRINT Software and first set of ink Accessories ClearMark Printer Ink Cartridge, Cyan -PRINTINK-C ClearMark Printer Ink Cartridge, Magenta -PRINTINK-M ClearMark Printer Ink Cartridge, Yellow -PRINTINK-Y ClearMark Printer Ink Cartridge, Black -PRINTINK-K ClearMark Printer - Replacement Ink Collector Unit -PRINTCOLLECT Plot partial marker cards Load up to five cards at a time (mix and match) Easy to use AB-Plot software System Requirements Operating system: Microsoft Windows Hard drive: MB available space Processor: Parallel or USB communication port Description Plotter Kit Includes Series E Plotter, - PLOTPEN ink pen, -PLOTPLT plate, communication cables, user manuals, ABPLOT software, and power adaptor. Plotter Pen Disposable pen,. mm tip Plotter Pen Disposable pen,. mm tip Plotter Pen Disposable pen,. mm tip, slow-drying ink ABPLOT Plotter software CD ROM - also available online at Plotter Ink Cartridge Requires -PLPEN Refillable pen Requires -PLINKCART Pen Adaptor Adaptor for ultra fine Sharpie pens, includes pen Cleaning Solution Used to unclog -PLPEN, requires -PLCLEAN Cleaning Kit Container and cloth to unclog - PLPEN, requires -PLSOLN Service Kit Inserts and cleaning pads to replace in pen station Series E Adapter Plate (additional) plate is already included with the Plotter kit Adaptor Plate For oversized markers (-MW-, - MW-, and MW-) Pkg Qty. -PLTKIT -PLOTPEN -PLOTPEN -PLOTPENS -PLOTSOFT -PLINKCART -PLPEN -PLOTADPT -PLSOLN -PLCLEAN -PLOTSERV -PLOTPLT -PLOTPLTA - Publication A-CAA-EN-P

62 Blank Markers Photo Snap-In Individual Markers -M Snap-In Linked Markers -MR Snap-In Hinged Markers Cable Markers -MW Requires cable ties. Requires -GMC Requires -PLOTPLTA For Use With Bulletin IEC Terminal Block Accessories Markers per Card Marker Size Marking Systems Pkg Qty. -L x mm -MX -L x mm -MX -J, L -J, L x mm -MX x mm -MX x mm -MX x mm -MX x mm -MX x mm -MX x mm -MX x mm -MX -J, L, ArmorPoint x mm -MX -J, L NEMA (-HM, -HM, -HM) Terminal Blocks, -CB Circuit Breakers NEMA (-HM) Terminal Blocks, -CB Circuit Breakers -W,R, -HA Relays x mm -MX x mm -MX x mm -MN x mm -MN x mm -MSX x mm -MSX -HN, -HN, Relay Sockets x mm -MSX PanelConnect x mm -MSX -C, -D Contactors, -CF Relays, Circuit Breakers, -E, -E -J, -L x mm -MSX x mm -MRX x mm -MRX x mm -MRX x mm -MRX x mm -MRX -WM, -WMD x mm -MSX -W, -HA, F Contact Block x mm -MSX -W, -H Relays x mm -MSX -W, -R, -H Relays x mm -MSX -W, -H Relays x mm -MSX -L External Diameter (mm) x mm -MHX x mm -MHX x mm -MHX Markers per Card Marker Size Pkg. Qty. from. in. (from. mm) x mm -MWX from. in. (from. mm) x mm from. in. (from. mm) x mm from. in. (from. mm) x mm - MWX - MWX - MWX.. in. (. mm) x mm -MW-.. (.) in. (.. [.] mm) x mm -MW-.. (.) in. (.. [.] mm) x mm -MW- Preferred availability cat. nos. are bold. Publication A-CAA-EN-P -

63 Bulletin IEC Terminal Block Accessories Marking Systems Blank Markers, Continued Photo Self-Adhesive Markers -MAS Wire Markers -MWC For Use With Markers per Card Marker Size Pkg Qty. Self-adhesive for any equipment x mm -MASX Bul. No. relays, self-adhesive for any equipment x mm -MASX -PICO GFX- Cont., self-adhesive for any equipment x mm -MASX.. in. (.. mm)/white. x mm -MWC-.. in. (.. mm)/white. x mm -MWC-.. in. (.. mm)/white x mm -MWC-.. in. (.. mm)/white. x mm -MWC-.. in. (.. mm)/white. x mm -MWC- Snap-In Individual Markers for Rockwell Automation products and Competitive Terminal BLocks -MC.. in. (.. mm)/white x mm -MWC- Wago x mm -MCWX Phoenix, Entrlec, Telemacanique, Legrand x mm -MCX Wieland and Telemecanique x mm -MCX Wago x mm -MCWXF Wago x mm -MCWX Wago x mm -MCWX Phoenix x mm -MCX Bul. No. -FB fuse holder and Phoenix x mm -MCX Bul. No. -FB fuse holder and Phoenix x mm -MCX Bul. No. -HL relays, and Phoenix, Wieland, Entrelec, Telemacanique, Legrand x mm -MCX Phoenix and Entrelec x mm -MCX Phoenix x mm -MCX Phoenix x mm -MCX Siemens x mm -MCSX Siemens x mm -MCSX Siemens x mm -MCSX Siemens x mm -MCSX Siemens x mm -MCSX Siemens x mm -MCSX - Preferred availability cat. nos. are bold. Publication A-CAA-EN-P

64 Bulletin IEC Terminal Block Accessories Marking Systems Pre-Printed Markers Pre-printed markers are packaged in quantities of with a minimum order quantity of cards. Catalog Number Explanation Code H V HU VU HR VR HUR VUR C a Marker Selection Code Mx MSX MCSX Mx MSX MCX Mx MSX MCW- Mx MSX MCW- Mx MSX MCW- Mx MSX MASX Mx MSX MASX MX MCX MASX Mx MCX MWX Mx MCX MWX Mx MCWX MWX Mx MCWX MWX Mx MCWXF MW- MRX MCWX MW- MRX MCWX MW- MRX MCX MWC- MRX MCX MWC- MRx MCX MWC- MHX MCX MWC-B MHX MCX MWC-R MHX MCX MCW-Y MMN MCSX MWC-B MN MCSX MWC-R MSx MCSX MWC-Y MSx MCSX MWC-B MSX MCSX MWC-R b Text Direction Description Horizontal Print Vertical Print Mx H - MWC-Y Horizontal Upside-down Print Vertical Upside-down Print Horizontal Print, reversed data for each column Vertical Print, reversed data for each column Horizontal Upside-down Print, reversed data for each column Vertical Upside-down Print, reversed data for each column Custom a b c -End L L L L U V W PE GND - -or- - -or- - -or- -or or- - -or- - -or- -or or- - -or- - -or- -or or- - -or- -or- - c Printing Selection Straight Fill Printing Option -End will start at and continue printing sequential numbers until the end of the card is reached. Sequential printing to end of card Continuous printing "L" on card Continuous printing "L" on card Continuous printing "L" on card Continuous printing "L" on card Continuous printing "U" on card Continuous printing "V" on card Continuous printing "W" on card Continuous printing "PE" on card Continuous printing "GND" on card Repeat Sequence Printing All Options in this section will print the defined sequence in a repeating fashion until all tags are filled. (Example - Option - with a marker selection of Mx will print - and -.) Block of sequential numbering. Blocks of within a range from. Block of sequential numbering. Blocks of within a range from. Block of sequential numbering. Blocks of within a range from. Block of sequential numbering. Blocks of within a range from. Single Sequence Printing All options in this section will print the defined sequence time only and will leave the rest of the marker tags blank. (Example - Option -S with a marker selection of Mx will print - and leave blank markers). -S -or- -S -or- -S - or- -or- -S -S -or- -S -or- -or- -S -S -or- -S -or- -or- -S -S -or- -S -or- -or- -S Block of sequential numbering. Blocks of within a range from. Block of sequential numbering. Blocks of within a range from. Block of sequential numbering. Blocks of within a range from. Block of sequential numbering. Blocks of within a range from. Publication A-CAA-EN-P -

65 Bulletin IEC Terminal Block Accessories Marking Systems Custom Printed Marker Cards. Download the AB-Print software (AB-Print) from the Allen-Bradley terminal block home page ( and install it.. Create your custom marker card using the AB-Print software and save your file.. Place the custom order by adding the letter C to the end of the marker cat. no. (Example: If the custom marker that was created in Step is Cat. No. -MX, an order will be placed with the new - MXC.) Then, document the order number for Step.. the custom marker file to RAMilwCustomMarkers@ra.rockwell.com. Include the following items: Allen Bradley order number (in the subject of the ) Created file (attached to the ) Quantity (the number of needed copies of the file) Company information (with a contact name and number in the ) Note: Minimum quantity is card per order. Description Pkg Qty. End anchor top marker carrier -GMC Electrical Warning Plate Markers Photo For Use With Color Pkg Qty. -J Yellow -EWPJ -J Yellow -EWPJ -J Yellow -EWPJ -J Yellow -EWPJ -L Yellow -EWPL -L Yellow -EWPL -L Yellow -EWPL -L Yellow -EWPL -L Yellow -EWPL -L Yellow -EWPL -L Yellow -EWPL -W Yellow -EWP -W Yellow -EWP- -W Yellow -EWP -W Yellow -EWP- -W Yellow -EWP -W Yellow -EWP- -W Yellow -EWP -W Yellow -EWP- -W Yellow -EWP -W Yellow -EWP- - Publication A-CAA-EN-P

66 Bulletin IEC Terminal Block Accessories Maximum number of multiple wire connections for copper conductors of the same cross-section and type for Allen-Bradley IEC Terminal Blocks. Cat. Nos. -J and L products are all recommended for one conductor per terminal. Wire range is defined in the cat. page for each of the products. In general, accessories for terminal blocks are not eligible for recognition by UL, CSA, or other third party approval agencies. The suitability of the installation must be judged in the end use application due to the wide variety of possible uses. However, accessories are designed to meet, and are tested to, the terminal block assembly requirements such as electrical spacings, etc. Wire Size [] # # # # # # # # # # # # # # # # / / / Number of the Same Size Wires Per Terminal -CA -CAM -H -H -H -H -HM -J -J -JQ -J -J -JF -JP -JTW (single side) -JTW (twin side) -J -JCTB -JQ -JTW -J -J -J -JC -JD -JDDF -JDDR -JDF -JDFB -JDPSS -JDPSSTP -JDPTP -JDRB*** -JDRC -JDSS -JD -JDC -JDC -JDG -JDGFB -JDGP -JDGPSS -JDGPSSTP -JDGPTP -JDG Publication A-CAA-EN-P -

67 Bulletin IEC Terminal Block Accessories Wire Size [] # # # # # # # # # # # # # # # # / / / Number of the Same Size Wires Per Terminal -JG -JG -JGQ -JG -JG -JGTW single side) -JGTW twin side) -JG -JGQ -JGTW -JG -JG -JG -JKD -JKDTP -JKD -JKDQ -JKDQTP -JKDTP -JKDTW -JKDTWTP -JPO -JSD -JTM -W -WS -W -W -W -WD -WDC -WG -WG -WM -WM -WMD -WMG -WR -WTF -WTFLN -WTFLP -WTS -WTSLN -WTSLP - Preferred availability cat. nos. are bold. Publication A-CAA-EN-P

68 Bulletin IEC Terminal Block Accessories Tie Point Terminal Blocks Type JDC, LDC, LDC, and LDC Description Type Rating Maximum total current flow through the terminal block Ambient temperature range Maximum working voltage Diode Terminal Blocks Type JDDR, JDDF, LDDF, and LDDR LDC JDC, LDC LDC LDC JDC, LDC, LDC A A A V V Operating All - + F (- + C) Storage All - + F (- + C) Description Symbol Type Rating Peak Repetitive Reverse Voltage Working Peak Reverse Voltage DC Blocking Voltage V (RRM) V (RWM) V (R) JDDF, JDDR, LDDF, LDDR Non-Repetitive Peak Reverse Voltage (Halfwave, single phase, Hz) V (RSM) JDDF, JDDR, LDDF, LDDR V RMS Reverse Voltage V (Rrms) JDDF, JDDR, LDDF, LDDR V Average Rectified Forward Current Single Phase, Resistive Load, Hz I (O) All. A Non-Repetitive Peak Surge Current (Surge applied at rated load) I (FSM) All A ( cycle) Maximum Forward Voltage Drop [I (F) =. A] V (F) All.V Ambient temperature range All parameters measured at F ( C). Maximum Reverse Current I (R) All μa Operating T (A) All - + F (- + C) Storage T (S) All - + F (- + C) Performance Data See this catalog, page Important-. Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of accelerated testing at elevated stress levels and the user should correlate it to actual application requirements. Actual performance is subject to Allen-Bradley WARRANTY and LIMIT OF LIABILITY. The maximum voltage rating of the diode terminal blocks listed in the above table should not be exceeded even though the maximum reverse voltage rating of the diode alone is V. Surge Suppressor Performance Characteristics and Electrical Component Data Surge Suppressor Terminal Blocks Performance Characteristic JDSS, JDPSS, JDSSTP, JDGPSS, JDGPSSTP, LDSS Nominal Working Voltage (Volts AC or DC) Maximum AC Working Voltage RMS Continuous ( Hz) Maximum DC Working Voltage Continuous Maximum Clamping Voltage at Current I p (/ μs Pulse) V I p = A Maximum Voltage Rate of Rise Bulletin Contactors Types A B Bulletin Contactors & Starters, Size Bulletin Relays Peak Current (/ μs Pulse) A Typical Leakage Current at Nominal AC Working Voltage <. ma Metal Oxide Varistor (MOV) Maximum Clamping Voltage at Current lp (/ μs Pulse) Maximum Transient Energy Maximum Power Dissipation The total current flow through these terminal blocks (the sum of all inputs or the sum of all outputs) must not exceed the rated current for the device. J. W V Publication A-CAA-EN-P -

Terminal Blocks/Wiring Systems/Signal Conditioners Table of Contents

Terminal Blocks/Wiring Systems/Signal Conditioners Table of Contents Terminal Blocks/Wiring Systems/Signal Conditioners Table of Contents IEC Accessories and Technical DIN Mounting Rails Page - End Barriers Page - End Anchors/Retainers Page - Partition Plates Page - Jumpers

More information

2.63" (65.9 mm) 0.20" (5.1 mm)

2.63 (65.9 mm) 0.20 (5.1 mm) Bulletin Screw Connection Terminal Blocks Double-Level Plug-In Style Terminal Blocks Dimensions are not intended to be used for manufacturing purposes. Note: Height dimension is measured from top of rail

More information

1.56" (39.5 mm) 0.20" (5.1 mm) Specifications terminal block Certifications CSA IEC CSA IEC CSA IEC 500V AC/DC 300V AC/DC AC/DC

1.56 (39.5 mm) 0.20 (5.1 mm) Specifications terminal block Certifications CSA IEC CSA IEC CSA IEC 500V AC/DC 300V AC/DC AC/DC Plug-In Style Terminal Blocks Dimensions are not intended to be used for manufacturing purposes. Note: Height dimension is measured from top of rail to top of terminal block.." (. mm) -JP -JPTP -JDP."

More information

2.33" (59.3 mm) 0.20" (5.1 mm) surge suppressor surge suppressor and test plug socket Certifications CSA IEC CSA IEC CSA IEC 300V AC/DC AC/DC

2.33 (59.3 mm) 0.20 (5.1 mm) surge suppressor surge suppressor and test plug socket Certifications CSA IEC CSA IEC CSA IEC 300V AC/DC AC/DC Bulletin Screw Connection Terminal Blocks Plug-In Style Terminal Blocks Dimensions are not intended to be used for manufacturing purposes. Note: Height dimension is measured from top of rail to top of

More information

0.20" (5.1 mm) 1.79" (45.4 mm) Feed-Through terminal block with 2 plug-in comb connections on one side.

0.20 (5.1 mm) 1.79 (45.4 mm) Feed-Through terminal block with 2 plug-in comb connections on one side. Bulletin Screw Connection Terminal Blocks Plug-In Connection Blocks Dimensions are not intended to be used for manufacturing purposes. Note: Height dimension is measured from top of rail to top of terminal

More information

1.56" (39.5 mm) 0.20" (5.1 mm)

1.56 (39.5 mm) 0.20 (5.1 mm) Bulletin Screw Connection Terminal Blocks Standard Feed-Through Blocks Dimensions are not intended to be used for manufacturing purposes. Note: Height dimension is measured from top of rail to top of terminal

More information

1.56" (39.5 mm) 0.20" (5.1 mm)

1.56 (39.5 mm) 0.20 (5.1 mm) Bulletin Standard Feed-Through Blocks Dimensions are not intended to be used for manufacturing purposes. Note: Height dimension is measured from top of rail to top of terminal block.." (. mm) -J -J -J."

More information

Bulletin 1492-J, -W 1492-L Type Screw Type Terminal Blocks Spring-Clamp Terminal Blocks

Bulletin 1492-J, -W 1492-L Type Screw Type Terminal Blocks Spring-Clamp Terminal Blocks Bulleting IEC Terminal Blocks Overview and Regulatory Information Bulletin -J, -W -L Type Screw Type Terminal Blocks Spring-Clamp Terminal Blocks Technology Screw terminations are a time-proven method

More information

Bulletin 1492-J, -W 1492-L Type Screw Type Terminal Blocks Spring-Clamp Terminal Blocks

Bulletin 1492-J, -W 1492-L Type Screw Type Terminal Blocks Spring-Clamp Terminal Blocks Bulleting IEC Terminal Blocks Overview and Regulatory Information Bulletin -J, -W -L Type Screw Type Terminal Blocks Spring-Clamp Terminal Blocks Technology Screw terminations are a time-proven method

More information

Bulletin 1492-J, -W 1492-L Type Screw Type Terminal Blocks Spring-Clamp Terminal Blocks

Bulletin 1492-J, -W 1492-L Type Screw Type Terminal Blocks Spring-Clamp Terminal Blocks Bulleting IEC Terminal Blocks Overview and Regulatory Information Bulletin -J, -W -L Type Screw Type Terminal Blocks Spring-Clamp Terminal Blocks Technology Screw terminations are a time-proven method

More information

Bulletin 1492-J, -W 1492-L Type Screw Type Terminal Blocks Spring-Clamp Terminal Blocks

Bulletin 1492-J, -W 1492-L Type Screw Type Terminal Blocks Spring-Clamp Terminal Blocks Bulleting IEC Terminal Blocks Overview and Regulatory Information Bulletin -J, -W -L Type Screw Type Terminal Blocks Spring-Clamp Terminal Blocks Technology Screw terminations are a time-proven method

More information

Terminal Blocks/Wiring Systems/Signal Conditioners Table of Contents

Terminal Blocks/Wiring Systems/Signal Conditioners Table of Contents Terminal Blocks/Wiring Systems/Signal Conditioners Table of Contents IEC Accessories and Technical Specifications DIN Mounting Rails Page - End Barriers Page - End Anchors/Retainers Page - Partition Plates

More information

Terminal Blocks/Wiring Systems/Signal Conditioners Table of Contents

Terminal Blocks/Wiring Systems/Signal Conditioners Table of Contents Terminal Blocks/Wiring Systems/Signal Conditioners Table of Contents IEC Accessories and Technical Specifications DIN Mounting Rails Page - End Barriers Page - End Anchors/Retainers Page - Partition Plates

More information

Terminal Blocks/Wiring Systems/Signal Conditioners Table of Contents

Terminal Blocks/Wiring Systems/Signal Conditioners Table of Contents Terminal Blocks/Wiring Systems/Signal Conditioners Table of Contents IEC Accessories and Technical Specifications DIN Mounting Rails Page - End Barriers Page - End Anchors/Retainers Page - Partition Plates

More information

Bulletin 1492-J, -W 1492-L Type Screw Type Terminal Blocks Spring-Clamp Terminal Blocks

Bulletin 1492-J, -W 1492-L Type Screw Type Terminal Blocks Spring-Clamp Terminal Blocks Bulleting IEC Terminal Blocks Overview and Regulatory Information Bulletin -J, -W -L Type Screw Type Terminal Blocks Spring-Clamp Terminal Blocks Technology Screw terminations are a time-proven method

More information

Terminal Blocks/Wiring Systems/Signal Conditioners Table of Contents

Terminal Blocks/Wiring Systems/Signal Conditioners Table of Contents Terminal Blocks/Wiring Systems/Signal Conditioners Table of Contents Screw Connection Terminal Blocks Mini Blocks... Page - Standard Feed-Through Blocks... Page - Space-Saver Feed-Through Blocks... Page

More information

SCREW CONNECTION TERMINAL BLOCKS

SCREW CONNECTION TERMINAL BLOCKS Terminal, IEC Catalogs > Industrial Controls Catalog > Terminal and Wiring Systems > Terminal, IEC > Screw Connection Terminal SCREW CONNECTION TERMINAL BLOCKS Introduction Sensor Thermocouple Mini- Grounding

More information

Terminal Blocks/Wiring Systems/Signal Conditioners Table of Contents

Terminal Blocks/Wiring Systems/Signal Conditioners Table of Contents Terminal Blocks/Wiring Systems/Signal Conditioners Table of Contents IEC Accessories and Technical Specifications DIN Mounting Rails Page - End Barriers Page - End Anchors/Retainers Page - Partition Plates

More information

Bulletin 1492 IEC Terminal Block Accessories Marking Systems

Bulletin 1492 IEC Terminal Block Accessories Marking Systems Bulletin IEC Terminal Block Accessories Marking Systems Marking Solutions Marking Solutions from Rockwell Automation enable efficient identification of terminal blocks and other components. The Allen-Bradley

More information

Bulletin 1492 Screw Type and Spring-Clamp IEC & NEMA Terminal Blocks

Bulletin 1492 Screw Type and Spring-Clamp IEC & NEMA Terminal Blocks Bulletin 1492 Screw Type and Spring-Clamp IEC & NEMA Terminal Blocks SCCR for Use with Fuses and Circuit Breakers UL Recognized Per UL 1059 Evaluated by UL for high-fault short-circuit current ratings

More information

Main catalogue. SNK Series Terminal Blocks Accessories Marking Solutions

Main catalogue. SNK Series Terminal Blocks Accessories Marking Solutions Main catalogue SNK Series Terminal Blocks Accessories Marking Solutions Summary See page 7 1SNK161026S0201 SNK Series, Terminal Blocks Screw clamp terminal blocks Accessories Marking solutions 1 A Smart

More information

Fused Disconnect Terminal Blocks for Miniature Fuses with CAGE CLAMP connection, Series

Fused Disconnect Terminal Blocks for Miniature Fuses with CAGE CLAMP connection, Series 28 Fused Disconnect Terminal Blocks for Miniature Fuses with CAGE CLAMP connection, Series 281... Blown fuse indication Exchange of fuse Blown fuse indication by LED or neon lamp Before exchanging the

More information

1492-CB 1492-GH 1492-GS

1492-CB 1492-GH 1492-GS 1 The Allen-Bradley Line of Devices Allen-Bradley offers 3 different lines of Circuit Breakers (Supplementary Protectors) and a line of branch circuit rated Fuse Holders. Allen-Bradley Thermal Magnetic

More information

Up to 60 A Class R 250 V and 600 V ferrule power distribution fuse blocks

Up to 60 A Class R 250 V and 600 V ferrule power distribution fuse blocks Technical Data 09 Effective June 06 Up to 60 A Class R 50 V and 600 V ferrule power distribution fuse blocks Catalog symbols: RM5060-_MW_ RM60030-_MW_ RM60060-_MW_ Features and benefits: Combination power

More information

8WH2 Spring-Loaded Terminals

8WH2 Spring-Loaded Terminals 8WH2 Spring-Loaded Terminals /2 Introduction /3 General data on 8WH /7 8WH through-type terminals 1) /18 8WH hybrid through-type terminals 1) /21 8WH fuse terminals /23 8WH isolating blade terminals /25

More information

8WH2 Spring-Loaded Terminals

8WH2 Spring-Loaded Terminals 8WH2 Spring-Loaded Terminals /2 Introduction /3 General data on 8WH /7 8WH through-type terminals 1) /18 8WH hybrid through-type terminals 1) /21 8WH fuse terminals /23 8WH isolating blade terminals /25

More information

Class J modular ferrule and knifeblade fuse blocks

Class J modular ferrule and knifeblade fuse blocks Technical Data10488 SupersedesFebruary 2016 Class J modular ferrule and knifeblade fuse blocks Knifeblade fuse blocks from 100 to 600 amps feature phase barriers between poles for additional safety with

More information

Class R 250V and 600V modular ferrule and knifeblade fuse blocks

Class R 250V and 600V modular ferrule and knifeblade fuse blocks Technical Data 1048 Class R 2V and 600V modular ferrule and Knifeblade fuse blocks from 100 to 600 amps feature phase barriers between poles for additional safety with up to four mounting holes per pole

More information

IEC TERMINAL BLOCKS. Screw Clamp Connection. Feed Through DIN Rail 433. Ground DIN Rail 439. Fuse Holder DIN Rail 445. Disconnect DIN Rail 448

IEC TERMINAL BLOCKS. Screw Clamp Connection. Feed Through DIN Rail 433. Ground DIN Rail 439. Fuse Holder DIN Rail 445. Disconnect DIN Rail 448 CONTROL LOGIC IEC TERMINAL BLOCKS TB c3controls line of IEC terminal blocks are both innovative and user-friendly. They are simple to install and are color-coded for easy circuit identification. From standard

More information

Electronic Circuit Breaker ESS20-0..

Electronic Circuit Breaker ESS20-0.. Electronic Circuit Breaker ES-0.. Description Electronic circuit breaker type ES-0.. is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 4 V switch-mode

More information

A powerful way to manage your power distribution challenges. I Power Distribution Blocks

A powerful way to manage your power distribution challenges. I Power Distribution Blocks I Power Distribution Blocks A powerful way to manage your power distribution challenges. Your problem: You re facing the enormously complex wiring requirements of an automated manufacturing facility. Or

More information

I power distribution. Blocks. challenges. Finger-Safe / FSPDB Series...I2. MPDB Open-Style PDBs... I4. MPDB62-MPDB63 (Mini) Open-Style PDBs...

I power distribution. Blocks. challenges. Finger-Safe / FSPDB Series...I2. MPDB Open-Style PDBs... I4. MPDB62-MPDB63 (Mini) Open-Style PDBs... Power Distribution Blocks I A powerful way to manage your power distribution challenges. Your problem: You re facing the enormously complex wiring requirements of an automated manufacturing facility. Or

More information

Main catalog. SNK series Terminal blocks. Phone: Fax: Web: -

Main catalog. SNK series Terminal blocks. Phone: Fax: Web:  - Main catalog SNK series Terminal blocks SNK series, terminal blocks, accessories, marking solutions Ranges and technologies presentation 2 1 PI-Spring terminal blocks 1 2 Screw clamp terminal blocks 49

More information

DBL distribution blocks 3x1 pole

DBL distribution blocks 3x1 pole TECHNICAL DATASHEET 1SNC166019D0201 - CATALOGUE PAGE 1SNC166020S0201 DBL distribution blocks 3x1 pole 84.6 3.33" 25 0.98" 32.5 1.28" 28.2 1.11" 23.5 0.93" 14.7 0.58" 36.3 1.43" 75 2.95" 62 2.44" 50.7 2"

More information

XB IEC Terminal Blocks. Screw Type Insulation Displacement Connection Type

XB IEC Terminal Blocks. Screw Type Insulation Displacement Connection Type XB IEC Terminal Blocks Screw Type Spring Cage Type Insulation Displacement Connection Type 2 XB IEC Terminal Blocks. Versatility, quality, and reliability. Sometimes it s the little things Eaton knows

More information

Standard terminal blocks

Standard terminal blocks T01005 001229 Standard terminal blocks DIN 1 - Spacing 6 mm + 0,05 (.28") M 4/6... Standard blocks Blue Orange Yellow Green ed Black White Brown Beige V0 Blue V0 M 4/6 0115 116.07 M 4/6.N 0125 116.01 M

More information

Capacitors. Individual & fixed bank. Individual & fixed capacitor banks. Low Voltage Network Quality

Capacitors. Individual & fixed bank. Individual & fixed capacitor banks. Low Voltage Network Quality Individual & fixed capacitor banks Low Voltage L O W V O L T A G E N E T W O R K Q U A L I T Y Individual & fixed bank Capacitors Description High reliability Well proven features of ABB dry type power

More information

Channel Mounted Terminal Blocks World-Class Terminal Block Solutions

Channel Mounted Terminal Blocks World-Class Terminal Block Solutions BY ELECTRO-MATIC PRODUCTS, INC. Mounted Terminal Blocks World-Class Terminal Block Solutions 300, 600 Volt & High Density Type EMM mounting type terminal blocks by Electro-Matic Products, Inc., are available

More information

Approvals (p. 906) 0 371 61 0 371 63 0 371 64 0 371 66 0 371 69 0 371 68 0 371 00 0 371 08 0 371 20 Connecting (p. 300) 1 connection - 1 entry/1 outlet ELECTRICAL FUNCTION TERMINAL BLOCKS INSULATION EQUIPOTENTIAL

More information

X-COM - and X-COM S-SYSTEM Pluggable Rail-Mounted Terminal Blocks

X-COM - and X-COM S-SYSTEM Pluggable Rail-Mounted Terminal Blocks X-COM - and X-COM S-SYSTEM Pluggable Rail-Mounted Terminal Blocks 2 Contents X-COM -SYSTEM 04 Installation 07 X-COM -SYSTEM at a Glance 08 X-COM S-SYSTEM 12 Installation 14 X-COM S-SYSTEM at a Glance 16

More information

Viking 3 - Screw connection Disconnect terminal blocks

Viking 3 - Screw connection Disconnect terminal blocks 87045 LIMOGES Cedex Telephone: (+33) 05 55 06 87 87 - Fax: (+33) 05 55 06 88 88 Viking 3 - Screw connection 1. General features... 1 2. Range...2 3. Standards... 2 4. Technical features... 3 5. Dimensions...

More information

Power Distribution Blocks

Power Distribution Blocks ower istribution Blocks A OWERFUL WAY TO MANAGE YOUR OWER ISTRIBUTION CHALLENGES Your problem: You re facing the enormously complex wiring requirements of an automated manufacturing facility. Or the compatibility

More information

Medium Voltage Metal-Enclosed Switches

Medium Voltage Metal-Enclosed Switches Medium Voltage Metal-Enclosed Switches Outdoor Medium Voltage Switch.1 Introduction Product Selection Guide....................................2 Medium Voltage Switch MVS Product Description......................................

More information

Switches Unlimited Phone: * Fax:

Switches Unlimited Phone: * Fax: For Info: sales@switchesunlimited.com www.switchesunlimited.com Phone: 800-1-0487 Fax: 718-67-6370 Page -4 Page -8 THREE-POLE CONTACTORS IEC Ith ratings in AC1 duty at 40 C: 16 to 1600A IEC Ie ratings

More information

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories Manual motor protectors Manual motor protectors Manual motor Protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certified

More information

ICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices

ICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices ICT TRANSFORMERS Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices TA SERIES INDUSTRIAL CONTROL TRANSFORMER Industrial control transformers

More information

CHCC_ (Class CC) CHM_ (UL midget/iec 10x38) CHPV_ (13/32 x 1-1/2 and 10x38 photovoltaic)

CHCC_ (Class CC) CHM_ (UL midget/iec 10x38) CHPV_ (13/32 x 1-1/2 and 10x38 photovoltaic) Supersedes Janaury 2016 BUSSMANN SERIES Specifications: Volts 600V (or less) UL 690V (or less) IEC 1000Vdc (or less) photovoltaic (PV) Amps 30A UL 32A IEC Short-Circuit Current Rating (SCCR) 33kA photovoltaic

More information

Industrial Control Transformers

Industrial Control Transformers 6 Industrial Control Transformers Section 6 Industrial Control Transformers provide a low and safe control voltage for the operation of electromagnetic devices, such as motor starters, contactors, solenoids

More information

CHCC_ (Class CC) CHM_ (UL midget/iec 10x38) CHPV_ (13/32 x 1-1/2 and 10x38 photovoltaic)

CHCC_ (Class CC) CHM_ (UL midget/iec 10x38) CHPV_ (13/32 x 1-1/2 and 10x38 photovoltaic) Supersedes August 2016 BUSSMANN SERIES Specifications: 2011/65/EU Volts 600 V (or less) UL 690 V (or less) IEC 1000 Vdc (or less) photovoltaic (PV) Amps 30 A UL 32 A IEC Short-Circuit Current Rating (SCCR)

More information

FEED-THROUGH 35 or 32mm DIN Rail

FEED-THROUGH 35 or 32mm DIN Rail FEED-THROUGH 35 or 32mm DIN Rail CTS2.5U-N CTS4U-N Altech U Series Universal Rail Mounting Standard Screw Clamp Feed through terminals are the most versatile terminals for wire-to-wire connection in control,

More information

Printview: 3-conductor ground terminal block; suitable for Ex e II applications - Item No.: /

Printview: 3-conductor ground terminal block; suitable for Ex e II applications - Item No.: / Printview: 3-conductor ground terminal block; suitable for Ex e II applications - Item No: 28-687/999-90 3-conductor ground terminal block; suitable for Ex e II applications Item No: 28-687/999-90 3-conductor

More information

Selection Guide. Control Circuit and Load Protection

Selection Guide. Control Circuit and Load Protection Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature

More information

Terminal blocks with Push In connection technology. Product Information

Terminal blocks with Push In connection technology. Product Information Terminal blocks with Push In connection technology Product Information Overview Terminal blocks with Push In connection technology (P-Series) Less is more With the P-Series, Weidmuller is presenting a

More information

Add-on blocks and accessories For BG series mini-contactors For BF series contactors For B series contactors...

Add-on blocks and accessories For BG series mini-contactors For BF series contactors For B series contactors... Three-pole versions up to 630A in IEC AC3 duty Four-pole versions up to 1600A in IEC AC1 duty Versions for power factor correction up to 100kvar at 400VAC Four-pole versions with NO+NC or 4NC main poles

More information

Page 2-4 Page 2-8. Page Page 2-13

Page 2-4 Page 2-8. Page Page 2-13 Page -4 Page -8 THREE-POLE CONTACTORS IEC Ith ratings in AC1 duty at 40 C: 16 to 1600A IEC Ie ratings in AC3 440V duty: 6 to 630A IEC Power ratings in AC3 400V duty:. to 335kW UL/CSA ratings: 3 to 500HP

More information

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E Issued to: SIEMENS AG DF CP R&D V 3 WERNER-VON-SIEMENS-STRASSE 48 92224 AMBERG, GERMANY This is to certify that representative samples of Combination Motor Controllers (See following pages for additional

More information

8WH6 ipo Plug-In Terminals

8WH6 ipo Plug-In Terminals / Introduction /3 /4 8WH6 through-type terminals /8 8WH6 fuse terminals /9 8WH6 isolating blade terminals /11 8WH6 isolating terminals /13 8WH6 two-tier terminals More technical product information: Service&Support

More information

PowerPact Circuit Breakers for Control Panel Disconnects Class 0611

PowerPact Circuit Breakers for Control Panel Disconnects Class 0611 Data Bulletin 0611DB0402 R04/16 05/2016 Replaces 0611DB0401 R11/11 PowerPact Circuit Breakers for Control Panel Disconnects Class 0611 Retain for future use. Introduction Certifications The electrical

More information

...at Altech, of course!

...at Altech, of course! FANTASTIC approved FERRULES...at Altech, of course! Approved for the US & Canadian Market Other great Altech CSA approved products: Miniature Circuit Breakers / Manual Motor Controllers DIN Rail and Panel

More information

PANEL PANEL MOUNTING COMPONENTS

PANEL PANEL MOUNTING COMPONENTS PANEL PANEL MOUNTING COMPONENTS For conventional wiring, Wöhner offers a comprehensive range of panel components for fastening to a DIN rail or mounting plate. The fuses and associated connection technology

More information

Compact Circuit Protector

Compact Circuit Protector Technical Data 10801 Supersedes August 018 BUSSMANN SERIES Compact Circuit Protector (cat. no. CCP) Contents Page 011/65/EU and specifications.... -3 Catalog numbers.... 4 Conductor information and available

More information

Medium Voltage Metal-Enclosed Switches

Medium Voltage Metal-Enclosed Switches Medium Voltage Metal-Enclosed Switches Outdoor Medium Voltage Switch.1 Medium Voltage Switch MVS Product Description............................................. 2 Application Description..........................................

More information

N0N A 250V One-Time Class H Fuse

N0N A 250V One-Time Class H Fuse 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-794 Fax: 936-560-4685 AllenWatson@elliottelectric.com N0N 250V One-Time Class H Fuse Catalog Number Manufacturer Description Weight per unit

More information

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL ed and

More information

Busbar Systems CHAPTER11

Busbar Systems CHAPTER11 763.422.22 763.422.2600 CHAPTER 38 SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Chapter Contents 60-mm Busbar System Overview...40 60-mm System Classic MCCB Mounting Reference....41 Support Spacing

More information

ZK2.5-SF-R PI-Spring Terminal Blocks For 5x20 fuses - with blown fuse indicator

ZK2.5-SF-R PI-Spring Terminal Blocks For 5x20 fuses - with blown fuse indicator Technical Datasheet SNK605D00 Catalogue Page SNK60S00 ZK.5-SF-R PI-Spring Terminal Blocks For 5x0 fuses - with blown fuse indicator - Protect your circuits with 5x0 fuse terminal blocks compliant with

More information

Rotary Disconnect Switches, Bulletin 194R

Rotary Disconnect Switches, Bulletin 194R ROCKWELL AUTOMATION PROCUREMENT SPECIFICATION PROCUREMENT SPECIFICATION Rotary Disconnect Switches Bulletin 194R NOTICE: The specification guidelines in this document are intended to aid in the specification

More information

Bulletin 1489 Circuit Breakers. Selection Guide

Bulletin 1489 Circuit Breakers. Selection Guide Bulletin 1489 s Selection Guide Bulletin 1489-A Overview/Description Bulletin 1489-A s Energy-limiting design protects downstream components better than conventional breakers during short circuits Field-mountable

More information

Low-Peak 600V Class RK1

Low-Peak 600V Class RK1 LPS-RK 600Vac/300Vdc, 1 10-60A, Dual Element, Time-Delay Fuses Dimensions - in 5" (± 0.31) 5.5" (± 0.31) Available with easyid open fuse indication 1/10 to 30A 0.81" (±0.008) 35 to 60A 1.06" (±0.008) Description:

More information

1489-M Circuit Breakers

1489-M Circuit Breakers Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Terminal design helps prevent wiring misses Scratch- and solventresistant printing Suitable

More information

selos Wieland jumpering system Perfect technology Copper Steel Wieland marking system Reliable identification Perfect technology Extremely rugged!

selos Wieland jumpering system Perfect technology Copper Steel Wieland marking system Reliable identification Perfect technology Extremely rugged! selos Wieland jumpering system Perfect technology Steel Copper Perfect technology Copper current bar guarantees low contact resistance Steel spring guarantees strength, durability, and long-term stability

More information

Compact Circuit Protector

Compact Circuit Protector Supersedes February 2019 BUSSMANN SERIES Compact Circuit Protector (cat. no. CCP2) 2011/65/EU CCP2 switch up to 100 A 200 A CCP2 switch 400 A CCP2 switch Contents Page 30, 60 and 100 amp switches s and

More information

Fuseholders PAGE. Fuseholders.

Fuseholders PAGE. Fuseholders. PAGE International Shock-Safe (Panel Mount).......................................................................... 467-468 Flip-Top Shock-Safe (Panel Mount)..................................................................................

More information

HIGH POWERBAR COPPER UL857

HIGH POWERBAR COPPER UL857 HIGH POWERBAR COPPER UL857 HIGH POWERBAR COPPER UL857 E+I Engineering s High Powerbar (HPB) UL857 range is a 600 Volt totally encased, non-ventilated, low impedance busduct. The range is available from

More information

ZS6-3S Screw Clamp Terminal Blocks Feed-through with 3 connections

ZS6-3S Screw Clamp Terminal Blocks Feed-through with 3 connections Technical Datasheet SNK663D00 Catalogue Page SNK667S00 ZS6-3S Screw Clamp Terminal Blocks Feed-through with 3 connections - Recommended for energy markets and highly demanding applications requiring that

More information

Bulletin 193-T1 Bimetallic Overload Relays

Bulletin 193-T1 Bimetallic Overload Relays Bulletin 193T1 Bimetallic Overload Relays Overload protection trip class 10 / 10A Phase loss protection Ambient temperature compensation Auxiliary contacts (1 N.O. and 1 N.C.) Manual/automatic reset mode

More information

Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide

Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide F Fixed-Depth Flange-Mounted Disconnect Switches Selection Guide F Fixed-Depth Flange-Mounted Disconnect Switches Product Cat. No. 1494F-N Disconnect Switch with Cat. No. 1494F-F Fuse Block Adapter Plate

More information

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5 DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5 1.1. APPLICABLE PUBLICATIONS 1.1.1. Publications listed below (including amendments, addenda, revisions, supplements, and errata), form a part of this

More information

RU Series Universal Relays

RU Series Universal Relays Full featured universal miniature relays Designed with environment taken into consideration Two terminal styles: plug-in and PCB mount Non-polarized LED indicator available on plug-in relays No internal

More information

ZK2.5-SP-4P PI-Spring Terminal Blocks Disconnect with plug - with test socket

ZK2.5-SP-4P PI-Spring Terminal Blocks Disconnect with plug - with test socket Technical Datasheet 1SNK1659D01 Catalogue Page 1SNK160S01 ZK2.5-SP-P PI-Spring Terminal Blocks Disconnect with plug - with test socket The flexible solution for fitting the component of your choice in

More information

Generator Fire Safety: Generator assemblies should be located outside the building.

Generator Fire Safety: Generator assemblies should be located outside the building. SECTION 33 70 00 - ELECTRICAL DISTRIBUTION PACKAGED GENERATOR ASSEMBLIES Generator Fire Safety: Generator assemblies should be located outside the building. All fuel piping from the outside of the building

More information

L-Frame LD F. Circuit Breaker/ Frame Ampere Rating. Trip Unit Rating/ Plug Ampere Rating LD T5 7 W

L-Frame LD F. Circuit Breaker/ Frame Ampere Rating. Trip Unit Rating/ Plug Ampere Rating LD T5 7 W July 07 5 Amperes -111 Product Selection This information is presented only as an aid to understanding catalog numbers. It is not to be used to build catalog numbers for circuit breakers or trip units.

More information

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator

More information

ZS4-SF Screw Clamp Terminal Blocks For 5 x 20 fuses

ZS4-SF Screw Clamp Terminal Blocks For 5 x 20 fuses Technical Datasheet SNK60D00 Catalogue Page ZS-SF Screw Clamp Terminal Blocks For x 0 fuses - Protect your circuits with x0 fuse terminal blocks compliant with IEC 607-7-3 standard (fuse not supplied with

More information

ZS4-S Screw Clamp Terminal Blocks Disconnect with blade

ZS4-S Screw Clamp Terminal Blocks Disconnect with blade Technical Datasheet SNK6D00 Catalogue Page SNK6S00 ZS4-S Screw Clamp Terminal Blocks Disconnect with blade - Ease your disconnect operations with the disconnect blade operated by hand or with a screwdriver,

More information

New VikingTM3, the innovation Screw or automatic spring connection

New VikingTM3, the innovation Screw or automatic spring connection New VikingTM3, the innovation Screw or automatic spring connection EXB 08023 Headquarters LEGRAND SNC 87045 Limoges Cedex - France :+33555068787 Fax : + 33 5 55 06 74 55 www.legrandgroup.com A NEW RANGE,

More information

Fusetron FRN-R Class RK5 250Vac/125Vdc A, dual element, time-delay fuses

Fusetron FRN-R Class RK5 250Vac/125Vdc A, dual element, time-delay fuses Technical Data1019 Supersedes July 2013 Fusetron FRN-R Class RK5 250Vac/125Vdc Catalog symbols: FRN-R-_ (non-indicating) FRN-R-_ID (indicating) Description: Eaton Bussmann series advanced protection, energy

More information

Selection Guide Motor Control Device Solutions

Selection Guide Motor Control Device Solutions Selection Guide Motor Control Device Solutions Expect more and get it from c3controls. Our portfolio of Motor Control Devices consists of worldclass products designed and manufactured to meet your requirements

More information

ZS6 Screw Clamp Terminal Blocks Feed-through

ZS6 Screw Clamp Terminal Blocks Feed-through Technical Datasheet SNK6008D00 Catalogue Page ZS6 Screw Clamp Terminal Blocks Feed-through Save space by connecting conductors up to 6 mm² (without insulated ferrule, CB certified) 0 AWG in just 6 mm 0.36

More information

Terminal blocks with clamping yoke and screw connection system

Terminal blocks with clamping yoke and screw connection system Overview W-Series Terminal blocks with clamping yoke and screw connection system High contact reliability for all standard electrical functions For a long time now, Weidmüller s W-Series terminal with

More information

Printview: Multilevel installation terminal block; N/L - Item No.:

Printview: Multilevel installation terminal block; N/L - Item No.: Multilevel installation terminal block; N/L Item No: 777-649 Multilevel installation terminal block; N/L Marking Business data Supplier WAGO Item no 777-649 EAN 404498883047 Content Order amount 0 Customer

More information

ZK2.5-SP PI-Spring Terminal Blocks Disconnect with plug - with test sockets

ZK2.5-SP PI-Spring Terminal Blocks Disconnect with plug - with test sockets Technical Datasheet SNK603D00 Catalogue Page SNK6038S00 ZK.5-SP PI-Spring Terminal Blocks Disconnect with plug - with test sockets The flexible solution for fitting the component of your choice in series

More information

CUBEFuse. CUBEFuse catalog numbers (amps)

CUBEFuse. CUBEFuse catalog numbers (amps) The power of space CUBEFuse The revolutionary Bussmann TM series Low-Peak TM CUBEFuse TM delivers the smallest footprint compared to any Class CC, J or RK fuse solution requiring up to 70% less space when

More information

UL Enclosed Disconnect Switches (Fused and Non-Fused)

UL Enclosed Disconnect Switches (Fused and Non-Fused) Product Selection UL Enclosed Disconnect Switches (Fused and Non-Fused) Catalog Number Explanation 194R-K Non-Metallic Enclosure UL Type 3/4/4X, IP66 194R-F Painted Steel Enclosure UL Type 3/4/12, IP66

More information

Bulletin 190-M Compact Starters. Selection Guide

Bulletin 190-M Compact Starters. Selection Guide Bulletin 190-M Selection Guide Bulletin 190-M Selection Guide 3 Bulletin 190-M Compact Design to 45mm Wide Common Adapter for Panel or DIN Rail Mounting Pre-Wired Assembly All Control Terminations Located

More information

Extra functions. Phone: Fax: Web: Accessories P-Series. Terminals, P-Series

Extra functions. Phone: Fax: Web: Accessories P-Series. Terminals, P-Series Accessories P-Series Terminals, P-Series Extra functions B Introduction The accessories for our other ranges of modular terminals can also be used with the P-Series in order to reduce the number of variations.

More information

Selection and application guide

Selection and application guide Selection and application guide 30A 400A fusible panelboards Coordination Panelboard www.usa.siemens.com/fusiblepanel Coordination panelboards Table of contents Subject Page Specifications 2-3 Enclosure

More information

INDUSTRIAL COMPONENTS CATALOGUE. Terminals, switches and fuse bases

INDUSTRIAL COMPONENTS CATALOGUE. Terminals, switches and fuse bases INDUSTRIAL COMPONENTS CATALOGUE Terminals, switches and fuse bases 2 Ensto at your service Ensto is an international industrial group and a family business specialising in the development, manufacture

More information

ZK6 PI-Spring Terminal Blocks Feed-through

ZK6 PI-Spring Terminal Blocks Feed-through Technical Datasheet SNK69D0 Catalogue Page SNK69S0 ZK6 PI-Spring Terminal Blocks Feed-through Combine high performance with compact dimensions: - 000 V AC / DC IEC 600 V UL, - Opt for the best marking

More information

POWER TERMINAL BLOCKS

POWER TERMINAL BLOCKS Terminal Blocks and Wiring Systems Catalogs > Industrial Controls Catalog > Terminal Blocks and Wiring Systems > Power Terminal Blocks POWER TERMINAL BLOCKS Introduction Standards Compliance High Fault

More information