OPERATOR FOR STREET BARRIERS SERIES GARD 4 INSTALLATION MANUAL G4040Z - G4040IZ. English

Size: px
Start display at page:

Download "OPERATOR FOR STREET BARRIERS SERIES GARD 4 INSTALLATION MANUAL G4040Z - G4040IZ. English"

Transcription

1 OPERATOR FOR STREET BARRIERS SERIES GARD 4 INSTALLATION MANUAL G4040Z - G4040IZ English EN

2 Index Legend of symbols page 4 Intended use and limits to use page 4 Intended use page 4 Limits to use page 4 Legislative references page 4 Description page 4 Technical data page 5 Parts list page 5 Installation page 6 Dimensions page 6 Preliminary checks page 6 Tools and materials page 6 Type of cable and minimum thicknesses page 7 Standard installation page 7 Preparing the automation base page 8 Installing the unit page 9 Balancing the barrier arm page 11 Adjusting the limit switches page 14 Control panel description page 16 Manual release of the barrier arm page 16 Main component parts page 17 Electrical connections page 17 Adjusting manoeuvring and braking speeds page 19 Selecting functions page 20 Adjustments page 20 Activating the radio command page 21 Connecting two barriers joined by a single command page 23 Safety instructions page 24 Maintenance page 24 Periodic maintenance page 24 Extraordinary maintenance page 26 Dismantling and disposal page 27 Trouble shooting page 27 Page 2 - Manual code: 119GU55 ver /2011 cancelli automatici s.p.a. - The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S.p.a. to notify said changes.

3 WARNING! important safety instructions: READ THIS PART CAREFULLY! Page 3 - Manual code: 119GU55 ver /2011 cancelli automatici s.p.a. - The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S.p.a. to notify said changes. Premise The motor must only be used in the way it is intended and for what it is designed. Any other use is to be considered dangerous. La cancelli automatici s.p.a. is not liable for any damage due to improper, errouneous and unreasonable use Keep these warnings together with the installation and users' manual for the automation system. Before installing (check what's there: if the outcome is negative, refrain from continuing until you are compliant with safety standards. Check that the part being automated is in proper working order, that it is balanced and aligned, and that it opens smoothly. Make sure you have suitable mechanical stops. If the operator will be installed less than 2.5 m from the floor or from any other access level, check whether you need additional protections and/ or warnings. With pedestrian doors framed int o the doors that will be automated, a system must be in place to block their opening during movement. Make sure the opening of the automated door leaf does not cause any trapping situations involving any surrounding fixed parts. Do not install the operator upside down or on any elements that may bend. If necessary, add suitable reinforcements at the fastening points. Do not fit onto door leafs that are installed on a slope, only on level ground. Check that any watering devices cannot wet the gearmotor from the bottm upwards. Installation Properly demarcate the entire site to prevent any unwanted access by unauthorised personnel to the working area, especially children and minors. Be careful when handling operators that weigh more than 20 kg (see intallation manual). You may have to equip yourself with safe moving gear. All opening commands (buttons, key-switch selectors, magnetic readers, and so on) must be installed at least 1.85 M from the gate's area of movement, or so that they are unreachable from the outside. Also, the direct commands (button or touch) must be installed at least 1.5 m high and not reachable by the public. All "maintained action" commands must be placed where the moving door leaves and transit areas are completely visible. If missing, affix a permament tag showing the position of the release device. Before delivering to the end user, check that the operator complies with Standard EN (impact testing), making sure the operator is properly set and adjusted and that all safety and protection devices and manual release work properly. Affix the Warning Signs in places that are clearly visible, where necessary (such as the gate tag). Instructions and special recommendations for users Keep gate-operating are free of any obstacles. Keep the photocells' range of operation free of vegetation. Do not allow children to play with the fixed command devices, or in the area of operation of the gate. Keep the remote control devices (transmitters) away from children. Check the system frequently, for any anomalies and signs of wear and tear or damage to the mobile structures, the component parts of the operator, all fastening points and devices, the cable and any accessible connections. Keep any jointed parts like hinges lubricated and clean of debris and the guide-sleds free of any friction. Perform functional checks to the photocells and sensitive edges every six months. Ensure proper cleaning of the glass on the photocells (use a slightly damp cloth); do not use solvents or other chemical products). If repairs or changes to the system settings become necessary, release the operator do not use it until all safety conditions are restored. Cut the main power supply before releasing the operator to perform manual openings. Check the instructions. It is FORBIDDEN for users to perform ANY OPERATIONS THAT ARE NOT EXPRESSLY REQUESTED OF SAID USERS in the manuals. For repairs, changes to the settings and extraordinary maintenance, CALL FOR TECHNICAL ASSISTANCE. Enter any interventions in the periodic maintenance log. Special instructions and recommendations for everyone Keep away from the hinges and any moving mechanical parts. Stay out of the operating range of the operator while it is moving. Do not oppose the movement of the operator as this may result in danger. Always be careful around the dangerous parts, which must be properly indicated with warning signs and black and yellow stripes. When using a selector switch or a maintained-action mode command, keep checking that no persons come within the operating range of the moving parts, until the command is released. The gate may move at any moment without warning. Always cut off the main electric power supply before performing any cleaning or maintenance.

4 Legend of symbols This symbol shows parts which must be read with care. This symbol means the parts which describe safety issues. This symbol tells you what to tell the end-user. Intended use and limits to use Intended use BARRIER automatic GARD 4 is " for l in PARKING FACILITIES or public, in areas residential or in zones intensive. Every installation and use other than that specified in this manual is forbidden. Limits to use Passage width is up to 3.75 metres and opening time is between 2 to 6 seconds. Legislative references Came Cancelli Automatici employs an ISO 9001:2000 certified quality management system and an ISO environmental management system. Came entirely engineers and manufactures in Italy. This product is compliant with: see statement of compliance. Description GARD 4 is engineered and built by CANCELLI AUTOMATICI S.p.A. in compliance with current safety code. The cabinet is made of galvanised, epoxy powder-coated 2.5 m thick steel sheeting, or of satinated AISI 304 staniless steel 2 mm thick. Inside there is a gearmotor and all of the mechanical moving parts. The control panel is housed in the upper dome. Designed around the anti-shearing dsafety function, it is fi tted with safety contacts in the hatch lock and in the emergency release lock.. The operators comes in two versions: 001G4040Z - Automatic barrier made of galvanised epoxy poweder-coated galvanised steel with a 24V D.C. powered gearmotor complete with control panel; 001G4040IZ - automatic barrier made of satinated AISI 304 stainless steel with a 24V D.C. powered gerarmotor complete with control panel; The following accessories are complementary to the GARD 4 operator: 001G Semi-rounded aluminium white-varnished barrier arm, 4 m long complete with transparent bottom cover-strip and antiimpact profi le1 ; 001G Rounded alumiium white-varnished barrier arm, 4 m long comlete with transparent botton cover-strip; 001G Attachment fl ange for rounded barrier-arm; 001G Balancing spring Ø40 (yellow); 001G Balancing spring Ø50 (green); 001G Balancing spring Ø55 (red); 001G Internal reinforcement for the G03750 semi-rounded barrier; 001G03755DX - Joint for semi-rounded barrier arm for right-hand barriers; 001G03755DX - Joint for semi-rounded barrier arm for left-hand barriers; 002LB38, - Electronic card for connecting three 12V-6Ah batteries ; The following accessories are optional on the GARD 4 operator; 001G Flashing dome-light. 001G Support for applying the DIR photocell onto the cabinet (cannot be used for barriers fi tted with swing skirt and/or swing rest; 001G Emergency battery housing support 001G Luminous cord to signal movement; 001G Luminous cord connecting cable; 001G Fixed support; 001G Swing rest; 001G Package of 20 red refl ective adhesive strips; 001G Swing skirt made of 2 m-long aluminium modules; WARNINGS! 001G02802 Cannot be used with with barriers with 001G0465 skirt and/or 001G02808 swing leg support 001G02808 For passage widths of up to maximum 3 m. 001G MUST use on barriers with passage widths exceeding 3 m or with the 03756G3 luminous cord. MUST use on barriers with passage widths exceeding 2.5 m or with 001G02808 swing leg support or with 001G0465 skirt. 001G02807 For passage width wider than 3.5 m use of the fixed support is mandatory. 001G G02808 Cannot be used together. Important! Make sure that the command and safety equipment and accessories are originals; this will ensure easy installation and maintenance of your system. Page 4 - Manual code: 119GU55 ver /2011 cancelli automatici s.p.a. - The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S.p.a. to notify said changes.

5 Technical data GEARMOTOR Power supply: 230V A.C. 50/60 Hz Motor power supply: 24V D.C. 50/60 Hz Assorbimento Max.: 1.3A (230V) / 15A (24V) Potenza: 300 W Max. torque: 600 Nm Reduction ratio: 1/202 Parts list Opening interval: 2 6 S Duty cycle: intensive Protection rating: IP54 Peso: 55 kg Insulation class: I Page 5 - Manual code: 119GU55 ver /2011 cancelli automatici s.p.a. - The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S.p.a. to notify said changes. OPERATOR ASSEMBLY UNIT 1) Upper dome 2) Shaft plate 3) Barrier-arm attachment mid-plate 4) Semi-rounded arm-attachment cover 5) Anti-shearing protective cover 6) Galvanised or painted stainless-steel cabinet 7) Inspection hatch 8) Gearmotor 9) Lever arm 10) Limit-switch assembly 11) ZL38 control panel ACCESSORIES 1) G aluminium white-varnished semi-rounded barrier arm L = 4 m. 2) G aluminium white-varnished rounded barrier arm L = 4 m. 3) G Balancing spring Ø40 (yellow) 4) G Balancing spring Ø50 (green) 5) G Balancing spring Ø55 (red) 6) G Swing skirt 7) G Support for DIR photocells 8) G Luminous cord 9) G Fixed support 10) G Swing rest 11) Red refl ective-strips stickers 11 12) G Flashing dome-light 13) G Emergency battery housing support 14) G Attachment fl ange for rounded barrier-arm BARRIER-ARM ATTACHEMENT VIEW INSPECTION HATCH VIEW

6 Dimensions Installation Installation must be carried by skilled, qualified technicians in accordance with current regulations. Preliminary checks Before beginning to install, do the following: Check that installing the operator does not create any hazardous situations; Set up a suitable omnipolar cut-off device, with distances greater than 3 mm between contacts, with sectioned power source; Check that any connections inside the container (made for continuity purposes of the protective circuit) be fitted with extra insulation compared to other internal conductive parts; Set up proper conduits and electric cable raceways, making sure these are protected from any mechanical damage; Tools and materials Make sure you have all the tools and materials needed to carry out the installation in total safety and in accordance with current regulations. The figure shows some examples of the tools needed by installers. Measurements in mm Page 6 - Manual code: 119GU55 ver /2011 cancelli automatici s.p.a. - The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S.p.a. to notify said changes.

7 Type of cable and minimum thicknesses Page 7 - Manual code: 119GU55 ver /2011 cancelli automatici s.p.a. - The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S.p.a. to notify said changes. Connection N.B. If cables are of a different length than that shown in the table, determine the cable section based on the actual draw and the number of connected devices and according the what is set forth in the CEI EN code of regulations. Per i collegamenti che prevedano più carichi sulla stessa linea (sequenziali), il dimensionamento a tabella deve essere riconsiderato sulla base degli assorbimenti e delle distanze effettivi. When connecting products not featured in this manual, only refer to the literature accompanying such products. 1 - GARD unit 2 - Control panel 3 - Aluminium barrier-arm 4 - Red reflective strips 5 - Luminous cord 6 - Motion warning flashing light 7 - Small column for photocells 8 - Photocells Type of cable Cable length 1 < 10 m 9 - Fixed support 10 -Metal mass detector 11 - Support and DIR PHOTOCELL 12 - Command device (keypad, magnetic key, card, and so on.) 13 - Small column for command device 11 2 Cable length 10 < 20 m Cable length 20 < 30 m Powered by 230 V AC 3G x 1.5 mm 2 3G x 2.5 mm 2 3G x 4 mm 2 Photocell transmitters FROR CEI 2 x 0.5 mm 2 2 x 0.5 mm 2 2 x 0.5 mm Photocell receivers 4 x 0.5 mm 2 4 x 0.5 mm 2 4 x 0.5 mm 2 CEI EN Accessories power source 24 V DC 2 x 0.5 mm x 0.5 mm 2 2 x 1 mm 2 Dispositivi di comando e di sicurezza 2 x 0.5 mm 2 2 x 0.5 mm 2 2 x 0.5 mm 2 Connecting the antenna RG58 max. 10 m Metal mass detector (see product literature delivered with product) Standard installation

8 Preparing the automation base The following illustrations are just examples, in that the space for securing the operator and accessories depends on the overall measurements. It is up to the installer to choose the most suited solution. - Dig a pit for the anchoring base and set up the required corrugated tubes for the connections coming out of the junction pit. N.B. the number of tubes depends on the type of installation and accessories used. - PLATE. - Fill the pit with cement and sink the anchoring base (that is, the plate + clamps) making sure the corrugated tubes pass throught he hole set up on the plate and that they are not fi lled with cement. The base must be perfectly level, clean and with the bolt threading completely on the surface. Wait at least 24 hrs for everything to solidify. - Remove any protruding nuts or wahsers, position the cabinet onto the base and fasten it. Note: install the cabinet with the inspection door facing an easily accessible direction. Page 8 - Manual code: 119GU55 ver /2011 cancelli automatici s.p.a. - The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S.p.a. to notify said changes.

9 Installing the unit - Remove the two top bolts from the upper dome, insert key into lock and turn counter-clockwise. Page 9 - Manual code: 119GU55 ver /2011 cancelli automatici s.p.a. - The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S.p.a. to notify said changes. DX - When installing on the right-hand side (DX), you need to invert the barrier-arm's direction of opening, by doing the following: - remove spring-hooking pin from the transmission arm (1); - use key to release the gearmotor; - turn the transmission arm (2); - relock the gearmotor; - Fit the anchoring pin into the hole opposite the initial one (3); - invert the cables on terminals M and N, FA and FC (4). - Lift up the dome and remove the cabinet hatch. - the barrier is set up to be lefthand (SX) installed. SX

10 - Position the mid-plate and arm-attachment cover using just one (M8x20) screw. Leave the creww loosened to facilitate subsequent arm insertion. - Insert the arm into the attachment cover and fasten using the M8x20 and M8x21 screws. Attachment plate Arm-attachment cover Mid plate UNI6954 ø2,9x13 UNI5931 M8x12 UNI5931 M8x20 UNI5931 M8x12 - Cut the raceway cover profi les to the length needed to insert them into the barrier arms' raceway. Procedure to follow on both sides. Finally fasten the arm end cap. Page 10 - Manual code: 119GU55 ver /2011 cancelli automatici s.p.a. - The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S.p.a. to notify said changes.

11 - Insert the protective anti-shearing casing onto the arm attachment cover and fasten it using the screws. Page 11 - Manual code: 119GU55 ver /2011 cancelli automatici s.p.a. - The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S.p.a. to notify said changes. UNI6954 ø3,9x19 Balancing the barrier arm - Before balancing the barrier-arm, check the table below, to see congruences among the chosen spring, any accessories and passage width: PASSAGE WIDTH (max m) Simple barrier arm* + anti-impact profile Simple barrier-arm * + anti-impact profile + luminous cord Simple barrier-arm* + skirt Simple barrier-arm* + luminous cord + skirt Asta semplice* + antiurto + appoggio mobile Simple barrier-arm* + anit-impact profile + luminous cord + swingrestb *A simple barrier arm is complete with transparent channel cover and endcap. SPRING TYPES G02040 Øe spring = 40 mm G04060 Øespring = 50 mm G06080 Ø e spring = 55 mm Passage width (m)

12 - Release the gearmotor and position the arm vertically, then lock it back into place. - Prepare the spring by tightening the ring-bolt below. Thee screw should then be fi tted onto the lug which is hooked to the transmission arm. Page 12 - Manual code: 119GU55 ver /2011 cancelli automatici s.p.a. - The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S.p.a. to notify said changes.

13 - Attach the ring-bolt to the anchoring bracket release the gearmotor and manually turn the spring to increase or decrease traction. The barrier arm must stabilise at 45. Page 13 - Manual code: 119GU55 ver /2011 cancelli automatici s.p.a. - The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S.p.a. to notify said changes. - Fit the counter nut and block the gearmotor back into place. Note: Check proper working order of the spring: - with barrier arm in vertical position, the spring is not under tension. - with barrier arm in horizontal position, the spring is loaded. - CARRY OUT THE ELECTRICAL CONNECTIONS ON CONTROL PANEL (SEE ELECTRICAL CONNECTIONS PARAGRAPH).

14 Adjusting the limit switches N.B.: procedure to carry out after making electrical connections to the control panel. Close the inspection hatch and power up the system. Activate the arm to check whether it is parallel to the road surface when close and at about 89 when open. Warning!The inspection hatch must be closed for opening and closing of the barrier arm to be safe and functional. - To adjust the vertical (opening) position of the barrier arm, close it, open the inspection hatch and turn the screw clockwise (to increase the the barrier-arm travel, or, counterclockwise to decrease it.. Note: before stopping completely the barrier-arm goes through a slowing down phase thanks to a cam that triggers the slow-down microswich. the microswitch is set at maximum advance. If you wish to delay the slowing-down pahse, loosen the screws of the micro-switch ledge screws, and position them outwards, see drawing. - Correct the horizontal (closing) position, in the same way. Page 14 - Manual code: 119GU55 ver /2011 cancelli automatici s.p.a. - The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S.p.a. to notify said changes.

15 - After checking the barrier-arm's opening and closing settings, defi nitively tighten the locking couter-nuts under the bolts. Page 15 - Manual code: 119GU55 ver /2011 cancelli automatici s.p.a. - The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S.p.a. to notify said changes. - Once all of the mechanical and electrical installation operations are completed fi t the cover over the control panel,... - Turn the key clockwise and lock the protective dome using the supplied Ø3.9x13 bolts. -...replace the inspection hatch and upper dome.

16 Manual release of the barrier arm - Insert the key into the lock and turn it clockwise. Manually lift the barrier arm and re-lock it by turning the key counter-clockwise. WARNING! The release action may result in danger for the user, when, for whatever reason - the arm is improperly fixed to the pin during mounting, the arm is broken or cracked during an accident, etc.- the tension springs no longer provide balance! This may result in sudden rotating movements of arm attachment and/or of the arm itself. Control panel description Engineered and built entirely by Came Cancelli Automatici S.p.A. The control panel is powered at 230V a.c., with 50/60Hz of maximum frequency. The command devices and accessories are powered by 24V. Warning! The accessories must not exceed 40 W overall. The control unit is un dispositivo amperometrico che controlla costantemente il valore della spinta del motore.. When the barrier arm runs into an obstacle, the amperometric sensor detects an overload in the thrust and acts on the movement: - when opening: by stopping the arm; - when closing: the barrier arm inverts its direction of travel until it fully opens, triggering the automatic closing. Warning! after three consecutive inversions, the barrier-arm stay upright, and excluded the automatic closing: to close, use the transmitter of closing button. All connections are protected by quick fuses, see table. The card provides and controls the following functions: - automatic closing after an opening command; - immediate closing; - pre-fl ashing movement indicator; - obstacle detection when barrier arm is stopped in any position; - Slave function; -increased braking action of the barrier arm. The available command modes are: - opening/closing; -opening/closing with maintained action; - opening; - total stop. Special trimmers regulate: - the working time for automatic closing; - the amperometric device's detection sensitivity; Optional accessories: - fl ashing cupola and luminous cord. - barrier-arm open light, signals that the barrier-arm is open - switches off at end of closing working-time; - LB38 card, when using batteries as a power source during blackouts. When the electric power is restored, it also recharges the batteries (see the technical literatue). WARNING: before acting inside the equipment, cut the main power supply and disconnect the batteries (if they are connected). TECHNICAL DATA line voltage 230 V - 50/60 Hz Maximum allowed power load 400 W power draw when idle 25 W max power for 24 V accessories 40 W circuit insulation class II container material ABS FUSE TABLE to protect: fuses for: Motor/s 10 A-F Electronic board (line) 3.15 A-F Accessories 2 A-F Command devices (control unit) 630 ma-f Page 16 - Manual code: 119GU55 ver /2011 cancelli automatici s.p.a. - The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S.p.a. to notify said changes.

17 Main component parts 1- Accessories fuse 2 - Line fuse 3 - Line control unit 4 - Motor fuse 5 - Acessories terminals 6 - Radio-requency card socket (see table on p. 19) 7 - Trimmer SENS: adjusting amperometric sensitivity 8 - Trimmer TCA: adjusting automatic closing time 9 - Functions selection Dip switch" 10 - Code memorising button 11 - Warning LED for radio code/automatic closing 12 - Adjusting connectors for speed and slow-downs 13 - Connectors for connecting the (LB38) battery charger 14 - Selection jumper for command type for button on Transformer 16 - Power source terminals 17 - Motor terminals 18 - Limit switch terminals Page 17 - Manual code: 119GU55 ver /2011 cancelli automatici s.p.a. - The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S.p.a. to notify said changes. 5 6 Electrical connections Gearmotor, limit switch 14 3 COM COM Description of already required wiring connections. " For right-hand installation, see pge 7. Opening microswitch Closing microswitch NC NC Orange White Orange Red White Red Black Blue Brown 16 Brown Blue Brown Motor 24V (d.c.)

18 Power supply Terminals for powering accessories: - normally at 24V A.C; - when emergency batteries are operating; Overall allowed power: 40 W + - Power supply 230V (a..c.)frequency 50/60 Hz Eyelet terminal with screw and washer for ground connection Command devices Stop button (N.C. contact) - Button to stop barrier arm Excludes automatic closing. To resume movement press the command button or trasmitter key. if unused, set Dip switch 9 to ON. Opening button (N.O. contact) - Barrier-arm opening command. Command button (N.O. contact ) - Barrier-arm opening and closing command. The barrier opens or inverts its movement depending on what is selected on Dip switch 2.) Check position of jumper (n 14, page 15) as shown in fi gure. Closing button (N.O. contact) - Barrier-arm closing command. This command is obligatory with the "maintained action" function. Position jumper as shown. Immediate closing (N.C.) contact Automatic closing of barrier arm after obstacle passes within operating range of safety devices if unused, set Dip switch 8 to ON. } } RX DIR photocells TX Page 18 - Manual code: 119GU55 ver /2011 cancelli automatici s.p.a. - The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S.p.a. to notify said changes.

19 Warning devices Flashing dome light and/ir luminous cord (Contact rating: 24 V - 32 W Max.) - Flashes while door opens and closes. Page 19 - Manual code: 119GU55 ver /2011 cancelli automatici s.p.a. - The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S.p.a. to notify said changes. Flashing light for open barrier Contact rated for: 24 V - 3 W Max.) - Signals that barrier-arm is raised, and switches of when the barrier-arm is lowered. Safety devices (N.C.) contact. di riapertura durante la chiusura» - Input for safety devices like photocells, compliant with law EN While the gate is closing, opening the contact will invert movement until it is fully openend. If unused, short-circuit contact 2-C1. Adjusting manoeuvring and braking speeds Per regolare la velocità di opening ( ) e chiusura, spostare il faston del trasformatore indicato con "A" su [Speed] -> [Min.]/[Max..]. [Min.] = minimum [Med.] = medium [Max.] = maximum Black RX Red White DIR photocells TX To ajust the slow-downs, move faston " B" to [Slow down.] -> [Min/Max.].

20 Selecting functions ON OFF 1 ON - Automatic closing - The automatic closing timer activates at the closing endpoint. The preset time is adjustabel, but it's in any case subject to any safety device intervention and does not activated after a Total Stop or in case of power failure (1 OFF - deactivated); 2 OFF - Function "opens-closes" with Button and Radio transmitter (with Radiofrequency card insert.). 2 ON - Function "only" with Button and Radio transmitter (with Radiofrequency card insert.). 3 ON - 24 V output on contact (10-E) barrier arm in movement and in closed position; 3 OFF- 24 V output on contact (10-E) barrier arm in movement; 4 ON - Maintained action - the barrier works by keeping the button pressed, a button 2-3 for opening, a button 2-7 for closing (position jumper n. 14 as shown in fi gure 16). 5 ON - Pre-flashing when opening and closing - After either an opening or closing command, the fl ashing light and/or luminous cord conencted on [10-E], fl ash/es for 5 secodns before cycle start. 6 ON - Obstacle detection - With motor idle (barrier arm closed, open or after a total stop command), it prevents any movement if the safety devices (e.g. photocells) detect an obstacle. 7 ON - "Slave" function - To be activated when having two combined barriers (see the Connecting two combined barriers paragraph); 8 OFF - Immediate closing dell asta ( - Automatic closing of barrier arm after obstacle passes within operating range of safety devices. Insert safety device on [2-C5]; if unused, set DIP switch to ON. 9 OFF - Total stop - - This function stops the door and then excludes any automatic closing cycle; use either the buttons or transmitter to resume movement. Connect button on [1-2]; if unused, set DIP switch to ON. 10 ON - Braking action - Increase braking action of the closing barrier arm (10 OFF - deactivated) Adjustments Default setting LIST TRIMMER Adjustments: - «A.C.T.» Adjusts opening waiting time. The gate closes automatically once this time-frame has elapsed. The waiting time may be adjusted from 1 second to 120 seconds. - «SENS» Adustes the amperometric sensitivity which controls the force developed by the motor during movement; if the force exceeds the adjusted level, the system intervenes and inverts the direction of travel. Page 20 - Manual code: 119GU55 ver /2011 cancelli automatici s.p.a. - The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S.p.a. to notify said changes.

21 Activating the radio command Antenna Connect RG58 antenna cable to the apposite terminals. Page 21 - Manual code: 119GU55 ver /2011 cancelli automatici s.p.a. - The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S.p.a. to notify said changes. Radio frequency card Plug in the radio-frequency card onto the electronic board AFTER CUTTING OFF THE MAIN POWER SUPPLY (and disconnecting the emergency batteries). N.B.: The electronic card recognises the radio-frequency card only when it is powered up. Transmitters ATOMO AT01 AT02 AT04 AF card Frequency-MHz Card Radiofrequency see instruction sheet in the packaging of the AF43SR radi-frequency card Serie transmitters FM 26,995 AF130 TFM FM AF150 TFM AM AF26 TOP AM AF30 TOP AM AF40 TOUCH AF43S / AF43SM TAM / TOP AF43SR ATOMO AF43S / AF43TW TWIN AM AF868 TOP

22 see instructions on box TOUCH TCH 4024 TCH 4048 TOP TOP-432A TOP-434A TOP- 302A TOP-304A TOP TOP-432NA TOP-434NA TOP-862NA TOP-864NA TOP-432S Memorisation TWIN TWIN 2 TWIN 4 PROG TAM T432 T434 T438 TAM-432SA - Keep button pressed PROG on the electronic card. The LED fl ashes ON and OFF. Radio card TFM T132 T134 T138 T152 T154 T158 Flashing LED - Press the button on the transmitter to be memorised. The LED will stay ON to confi rm memorisation is OK. LED on Page 22 - Manual code: 119GU55 ver /2011 cancelli automatici s.p.a. - The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S.p.a. to notify said changes.

23 R R R Connecting two barriers joined by a single command - Establish which barrier will be Master and which the Slave. SX DX Page 23 - Manual code: 119GU55 ver /2011 cancelli automatici s.p.a. - The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S.p.a. to notify said changes. - command card Slave, position the Dip-switches 7 in ON, the connection of the power source L-N, device output of the 10-E, speed and I of the BARRIER Master. - the connection card command I RX-TX-GND. Black Red Screened cable 2402C 22AWG 7 ON COMMAND CARD MASTER COMMAND CARD MA- STER COMMAND CARD SLAVE Red Black COMMAND CARD SLAVE - command card Master, all I connection (electrical connections), procedure v installation " for command a. Distance, I and Adjustments.

24 Safety instructions Important general safety instructions This product is only intended to be used for the purpose it was designed. Any other use is therefore improper and dangerous. The manufacturer is not liable for any damage caused by improper, wrongful or unreasonable use. Stay away from working mechanical parts. Stay out of the working range of the moving operator. Do not oppose the movement of the operator as this may result in danger. Do not allow children to play to loiter within the working range of the operator. Keep transmitters and any other command devices away from children, to prevent the operator from being activated by mistake. Immediately stop using the operator if any anomaly is manifested. Maintenance Danger of hand crushing Danger high voltage Transit forbidden during operation Periodic maintenance Periodic servicing performed by end-user are wiping clean the photocell's glass front pieces and checking for proper working state of safety devices and that the operator is free of any obstacles. We also suggest to periodically check the state of lubrication and tightness of screws on the operator. To check the efficiency of the safety devices, wave an object in front of the photocells during closing cycle, if the operator inverts or halts its movement, the photocells are working properly. This is the only maintenance job that can be done with the spring-tension of the barrier loaded. Before performing any job we highly recommend to cut off the main power, to prevent any dangerous situations from possible accidental movements by the barrier. -To wipe clean the photocell glass, use a slightly damp cloth, and do not use any solvents or other chemical products that may ruin the device. - Check that the photocells are free of any vegetaion blocking them, and that there are no obstacles to the free movement of the arm. Page 24 - Manual code: 119GU55 ver /2011 cancelli automatici s.p.a. - The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S.p.a. to notify said changes.

25 Periodic maintenance log to be done by users (every 6 months) Date Notes Signature Page 25 - Manual code: 119GU55 ver /2011 cancelli automatici s.p.a. - The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S.p.a. to notify said changes.

26 Extraordinary maintenance The following table is used to log extraordinary maintenance, repair and improvement jobs done by the specialised external firms. N.B. All extraordinary maintenance jobs must be carried out by skilled technicians. Registro manutenzione straordinaria Timbro installatore Nome operatore Data intervento Firma tecnico Firma committente Job carried out Timbro installatore Nome operatore Data intervento Firma tecnico Firma committente Job carried out Timbro installatore Nome operatore Data intervento Firma tecnico Firma committente Job carried out Timbro installatore Nome operatore Data intervento Firma tecnico Firma committente Job carried out Timbro installatore Nome operatore Data intervento Firma tecnico Firma committente Job carried out Timbro installatore Nome operatore Data intervento Firma tecnico Firma committente Job carried out Page 26 - Manual code: 119GU55 ver /2011 cancelli automatici s.p.a. - The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S.p.a. to notify said changes.

27 Trouble shooting Page 27 - Manual code: 119GU55 ver /2011 cancelli automatici s.p.a. - The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S.p.a. to notify said changes. PROBLEM REFERENCE CHECK The operator neither opens nor closes Lock the inspection hatch using the key and check the release lock The operator opens but does not shut Deactivate the Maintained action function via Dip-switch The operator closes but does not open Check power source and fuses The operator does not carry out the automatic The N.C. safety contacts are open closing The radio-control does not work Deactivate the master-slave function The operator inverts the direction of travel Check balancing and tighteness of springs Only one radio-control works. 22 Deactivate the obstacle detection function via dip switch The photocell does not work Check opening limit-switch The led warning light flashes quickly Check closing limit-switch The led warning light stays lit chiusura automatica. the Dip-switches The operator does not fully complete cycle Check for the proper direction of travel Cannot balance the arm Check the command devices The operator does not decelerate Cut off and bring back power to card or check the TOP/ TAM jumper on the AF43S card The operator does not run on the emergency Check the Arm length/applied Accessories ratio batteries The operator is slow when starting 7 Memorise the radio code again 18 - Adjust sensitivity 22 - Insert or duplicate the same code in all transmitters 23 - Activate the photocell via Dip-switch 24 - Connect the photocells in series and not in parallel fashion 25 - Check the batteries 26 - Respect the polarities when powering up the photocells Dismantling and disposal On its premises, Cancelli Automatici S.p.A. implements a certified Environmental Management System in compliance with the UNI EN ISO standard to ensure environmental protection. Please help us to safeguard the environment. At we believe this to be one of the fundamentals in its market operations and development strategies. Just follow these short disposal instructions: DISPOSING OF THE PACKAGING The components of the packaging (that is, cardboard, plastic, and so on) are solid urban waste and may be disposed of without much trouble, simply by separating them for recycling. Before proceeding it is always a good idea to check your local legislation on the matter. DO NOT DISPOSE OF IN NATURE! PRODUCT DISPOSAL Our products are made up of various materials. Most of these (aluminium, plastic, iron, electric cables) are solid urban waste. Can be recycled by separating and Other components (i.e. electronic cards, remote control batteries, etc. ) may contain hazardous substances. These must therefore be handed over the specially authorised disposal firms. Prima di procedere è sempre opportuno verificare le normative specifiche vigenti nel luogo di smaltimento. DO NOT DISPOSE OF IN NATURE!

28 01_2011 France S.a. 7, Rue Des Haras Z.i. Des Hautes Patures Nanterre Cedex (+33) (+33) FRANCE GERMANY Gmbh Seefeld Akazienstrasse, Seefeld Bei Berlin (+49) (+49) Automatismes S.a. 3, Rue Odette Jasse Marseille (+33) (+33) FRANCE U.A.E. Gulf Fze Office No: S10122a2o210 P.O. Box Jebel Ali Free Zone - Dubai (+971) (+971) English - Manual code: 119GU55 ver /2011 cancelli automatici s.p.a. The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S.p.A. to notify said changes. Automatismos S.a. C/juan De Mariana, N. 17-local Madrid (+34) (+34) United Kingdom Ltd. Unit 3 Orchard Business Park Town Street, Sandiacre Nottingham - Ng10 5bp (+44) (+44) Group Benelux S.a. Zoning Ouest Lessines (+32) (+32) Americas Automation Llc NW 122nd St. Medley, FL (+1) (+1) Gmbh Kornwestheimer Str Korntal Munchingen Bei Stuttgart (+49) (+49) SPAIN GREAT BRITAIN BELGIUM U.S.A GERMANY RUSSIA PORTUGAL INDIA ASIA Rus Umc Rus Llc Ul. Otradnaya D. 2b, Str. 2, office , Moscow (+7) (+7) (ext. 226) Portugal Ucj Portugal Unipessoal Lda Rua Liebig, nº Barreiro (+351) (+351) India Automation Solutions Pvt. Ltd A - 10, Green Park New Delhi (+91) /256 (+91) Asia Pacific 60 Alexandra Terrace #09-09 Block C, The ComTech Singapore (+65) (+65) Cancelli Automatici S.p.a. Via Martiri Della Libertà, Dosson Di Casier (Tv) (+39) (+39) Informazioni Commerciali ITALY ITALY Sud s.r.l. Via F. Imparato, 198 Centro Mercato 2, Lotto A/ Napoli (+39) (+39) Service Italia S.r.l. Via Della Pace, Dosson Di Casier (Tv) (+39) (+39) Assistenza Tecnica ITALY ITALY Global Utilities s.r.l. Via E. Fermi, Gessate (Mi) (+39) (+39)

AUTOMATION FOR SWING GATES SERIES FERNI INSTALLATION MANUAL FE4024. English

AUTOMATION FOR SWING GATES SERIES FERNI INSTALLATION MANUAL FE4024. English AUTOMATION FOR SWING GATES SERIES FERNI INSTALLATION MANUAL FE4024 English EN Index Legend of symbols p. 4 Intended use and limits p. 4 Intended use p. 4 Limits to use p. 4 Description p. 4 Technical features

More information

OPERATOR FOR STREET BARRIERS 119G56EN. Barrierline SERIES GARD INSTALLATION MANUAL G English

OPERATOR FOR STREET BARRIERS 119G56EN. Barrierline SERIES GARD INSTALLATION MANUAL G English 119G56EN Barrierline OPERATOR FOR STREET BARRIERS SERIES GARD INSTALLATION MANUAL G12000 English EN Foreword Use of the products must be restricted to its intended use (i.e. that for which it was expressly

More information

CONTROL PANEL FOR 24V GEARMOTORS 319U33EN Z CONTROL PANELS INSTALLATION MANUAL ZL19N. English

CONTROL PANEL FOR 24V GEARMOTORS 319U33EN Z CONTROL PANELS INSTALLATION MANUAL ZL19N. English 319U33EN CONTROL PANEL FOR 24V GEARMOTORS Z CONTROL PANELS INSTALLATION MANUAL ZL19N English EN "IMPORTANT INSTALLATION SAFETY INSTRUCTIONS" WARNING: IMPROPER INSTALLATION MAY RESULT IN SERIOUS HARM. PLEASE

More information

AUTOMATION FOR STREET BARRIERS GARD 8 SERIES INSTALLATION MANUAL G2080Z - G2080IZ. English

AUTOMATION FOR STREET BARRIERS GARD 8 SERIES INSTALLATION MANUAL G2080Z - G2080IZ. English AUTOMATION FOR STREET BARRIERS GARD 8 SERIES INSTALLATION MANUAL G2080Z - G2080IZ English EN IMPORTANT SAFETY INSTRUCTIONS FOR INSTALLATION CAUTION: IMPROPER INSTALLATION MAY CAUSE SERIOUS DAMAGE, FOLLOW

More information

AUTOMATION FOR STREET BARRIERS 119GU44EN GARD 8 SERIES INSTALLATION MANUAL G2081Z. English

AUTOMATION FOR STREET BARRIERS 119GU44EN GARD 8 SERIES INSTALLATION MANUAL G2081Z. English 119GU44EN AUTOMATION FOR STREET BARRIERS GARD 8 SERIES INSTALLATION MANUAL G2081Z English EN IMPORTANT SAFETY INSTRUCTIONS FOR INSTALLATION CAUTION: IMPROPER INSTALLATION MAY CAUSE SERIOUS DAMAGE, FOLLOW

More information

IN-GROUND OPERATOR FOR SWING GATES FROG SERIES INSTALLATION MANUAL FROG A24 / FROG A24E. English

IN-GROUND OPERATOR FOR SWING GATES FROG SERIES INSTALLATION MANUAL FROG A24 / FROG A24E. English IN-GROUND OPERATOR FOR SWING GATES FROG SERIES INSTALLATION MANUAL FROG A24 / FROG A24E English EN Foreword Use of the products must be restricted to its intended use (i.e. that for which it was expressly

More information

STREET BARRIERS SERIES GARD INSTALLATION MANUAL G3750. English

STREET BARRIERS SERIES GARD INSTALLATION MANUAL G3750. English STREET BARRIERS SERIES GARD INSTALLATION MANUAL G3750 English EN Index Legend of symbols p. 4 Intended use and limits to use p. 4 Intended use p. 4 Limits to use p. 4 Description p. 4 Technical data p.

More information

AUTOMATION FOR STREET BARRIERS GARD 8 SERIES INSTALLATION MANUAL G G2080I

AUTOMATION FOR STREET BARRIERS GARD 8 SERIES INSTALLATION MANUAL G G2080I AUTOMATION FOR STREET BARRIERS GARD 8 SERIES INSTALLATION MANUAL G2080 - G2080I IMPORTANT SAFETY INSTRUCTIONS FOR INSTALLATION CAUTION: IMPROPER INSTALLATION MAY CAUSE SERIOUS DAMAGE, FOLLOW ALL INSTALLATION

More information

IN-GROUND OPERATOR FOR SWING GATES FROG SERIES INSTALLATION MANUAL FROG-A 230V

IN-GROUND OPERATOR FOR SWING GATES FROG SERIES INSTALLATION MANUAL FROG-A 230V IN-GROUND OPERATOR FOR SWING GATES FROG SERIES INSTALLATION MANUAL FROG-A 230V IMPORTANT INSTALLATION, SAFETY INSTRUCTIONS CAUTION: IMPROPER INSTALLATION MAY CAUSE SERIOUS DAMAGE, FOLLOW ALL INSTALLATION

More information

AUTOMATION FOR STREET BARRIERS GARD 8 SERIES INSTALLATION MANUAL G2080Z - G2080IZ

AUTOMATION FOR STREET BARRIERS GARD 8 SERIES INSTALLATION MANUAL G2080Z - G2080IZ AUTOMATION FOR STREET BARRIERS GARD 8 SERIES INSTALLATION MANUAL G2080Z - G2080IZ IMPORTANT SAFETY INSTRUCTIONS FOR INSTALLATION CAUTION: IMPROPER INSTALLATION MAY CAUSE SERIOUS DAMAGE, FOLLOW ALL INSTALLATION

More information

AUTOMATION FOR STREET BARRIERS GARD 4 SERIES INSTALLATION MANUAL G G4041I

AUTOMATION FOR STREET BARRIERS GARD 4 SERIES INSTALLATION MANUAL G G4041I AUTOMATION FOR STREET BARRIERS GARD 4 SERIES INSTALLATION MANUAL G4041 - G4041I IMPORTANT SAFETY INSTRUCTIONS FOR INSTALLATION CAUTION: IMPROPER INSTALLATION MAY CAUSE SERIOUS DAMAGE, FOLLOW ALL INSTALLATION

More information

AUTOMATION SYSTEM FOR SWING GATES FROG SERIES INSTALLATION MANUAL SUPERFROG

AUTOMATION SYSTEM FOR SWING GATES FROG SERIES INSTALLATION MANUAL SUPERFROG AUTOMATION SYSTEM FOR SWING GATES FROG SERIES INSTALLATION MANUAL SUPERFROG IMPORTANT SAFETY INSTRUCTIONS FOR INSTALLATION CAUTION: IMPROPER INSTALLATION MAY CAUSE SERIOUS DAMAGE, FOLLOW ALL INSTALLATION

More information

UNDERGROUND OPERATOR FOR SWING GATES 119AS45EN. Installation manual FROG-A / FROG-AV / FROG-AE. English

UNDERGROUND OPERATOR FOR SWING GATES 119AS45EN. Installation manual FROG-A / FROG-AV / FROG-AE. English 119AS45EN UNDERGROUND OPERATOR FOR SWING GATES Installation manual FROG-A / FROG-AV / FROG-AE English EN WARNING! important safety instructions: READ CAREFULLY! NECESSARY AND IN A VISIBLE PLACE SPECIAL

More information

OPERATOR FOR GARAGE DOORS FA00047-EN INSTALLATION AND OPERATION V6000. English

OPERATOR FOR GARAGE DOORS FA00047-EN INSTALLATION AND OPERATION V6000. English OPERATOR FOR GARAGE DOORS FA00047-EN INSTALLATION AND OPERATION V6000 EN English WARNING! important safety instructions for people: READ CAREFULLY! Premise This product should only be used for the purpose

More information

QUICK ROAD BARRIERS SERIES GARD INSTALLATION MANUAL G G3000I. English

QUICK ROAD BARRIERS SERIES GARD INSTALLATION MANUAL G G3000I. English QUICK ROAD BARRIERS SERIES GARD INSTALLATION MANUAL G3000 - G3000I English EN Index Legend of symbols p. 4 Intended use and limits to use p. 4 Intended use p. 4 Limits to use p. 4 Description p. 4 Technical

More information

AUTOMATION SYSTEMS FOR SLIDING GATES BX SERIES INSTALLATION MANUAL BX-243. English

AUTOMATION SYSTEMS FOR SLIDING GATES BX SERIES INSTALLATION MANUAL BX-243. English AUTOMATION SYSTEMS FOR SLIDING GATES BX SERIES INSTALLATION MANUAL BX-243 English EN IMPORTANT INSTALLATION, SAFETY INSTRUCTIONS CAUTION: IMPROPER INSTALLATION MAY CAUSE SERIOUS DAMAGE, FOLLOW ALL INSTALLATION

More information

Documentazione Tecnica SERIES. BARRIER Series Série Baureihe Serie GARD ROAD CAME 07/97 119G56 -GB G12000

Documentazione Tecnica SERIES. BARRIER Series Série Baureihe Serie GARD ROAD CAME 07/97 119G56 -GB G12000 Documentazione Tecnica SERIES GARD ROAD BARRIER Series Série Baureihe Serie 56 rev. 1.1 CAME 07/97 119G56 -GB G00 Description: - Motorised barrier for control of passages with width of up to 1 m. - Designed

More information

OPERATORS FOR GARAGE DOORS FA00045-EN INSTALLATION MANUAL VER10 - VER12. English

OPERATORS FOR GARAGE DOORS FA00045-EN INSTALLATION MANUAL VER10 - VER12. English OPERATORS FOR GARAGE DOORS FA00045-EN INSTALLATION MANUAL VER10 - VER12 EN English WARNING! Important safety instructions for people: READ CAREFULLY! PREMISE THIS PRODUCT SHOULD ONLY BE USED FOR THE PURPOSE

More information

VER KIT. Installation Instructions TECHNICAL HELPLINE

VER KIT. Installation Instructions TECHNICAL HELPLINE CAME UNITED KINGDOM LTD UNIT 3 ORCHARD PARK INDUSTRIAL ESTATE, TOWN STREET, SANDIACRE, NOTTINGHAM NG10 5BP TEL: 0115 921 0430 FAX: 0115 921 0431 TECHNICAL HELPLINE 0115 921 0430 INTERNET - www.cameuk.com

More information

AUTOMATION SYSTEMS FOR SLIDING GATES INSTALLATION MANUAL BX-246. English

AUTOMATION SYSTEMS FOR SLIDING GATES INSTALLATION MANUAL BX-246. English AUTOMATION SYSTEMS FOR SLIDING GATES BX SERIES INSTALLATION MANUAL BX-246 English EN IMPORTANT INSTALLATION, SAFETY INSTRUCTIONS CAUTION: IMPROPER INSTALLATION MAY CAUSE SERIOUS DAMAGE, FOLLOW ALL INSTALLATION

More information

OMATION FOR SLIDING GATES LINESTAR INSTALLATION MANUAL

OMATION FOR SLIDING GATES LINESTAR INSTALLATION MANUAL AUTOMA OMATION FOR SLIDING GATES LINESTAR INSTALLATION MANUAL CONTENTS 1.0 Description of the system parts page 3 1.1 Description of the parties of the group gearmotor page 3 2.0 General characteristics

More information

INDUSTRIAL DOOR OPERATOR 119CT54EN INSTALLATION MANUAL C-BX_C-BXK_CBXE_CBXEK C-BXT_C-BXET_C-BXE24. English

INDUSTRIAL DOOR OPERATOR 119CT54EN INSTALLATION MANUAL C-BX_C-BXK_CBXE_CBXEK C-BXT_C-BXET_C-BXE24. English INDUSTRIAL DOOR OPERATOR 9CT54EN INSTALLATION MANUAL C-BX_C-BXK_CBXE_CBXEK C-BXT_C-BXET_C-BXE4 EN English WARNING! important safety instructions for people: READ CAREFULLY! PREMISE THIS PRODUCT SHOULD

More information

AUTOMATION FOR SLIDING GATES BX SERIES INSTALLATION MANUAL BX243U/BX243CU

AUTOMATION FOR SLIDING GATES BX SERIES INSTALLATION MANUAL BX243U/BX243CU AUTOMATION FOR SLIDING GATES BX SERIES INSTALLATION MANUAL BX243U/BX243CU IMPORTANT UL-325 SAFETY INSTRUCTIONS BX Series It is extremely important that all parties involved in the installation and operation

More information

SDN4 / SDN6 / SDN8 / SDN10

SDN4 / SDN6 / SDN8 / SDN10 SLIDING GATE OPERATOR FA00014-EN BXV INSTALLATION MANUAL SDN4 / SDN6 / SDN8 / SDN10 SDN4-110 / SDN6-110 / SDN8-110 / SDN10-110 EN English GENERAL WARNINGS CAUTION: Important safety instructions. Follow

More information

TRAFFI BARRIE COST EFFECTIVE BARRIER SOLUTIONS TRAFFIC BARRIERS

TRAFFI BARRIE COST EFFECTIVE BARRIER SOLUTIONS TRAFFIC BARRIERS TRAFFI BARRIE TRAFFIC BARRIERS COST EFFECTIVE BARRIER SOLUTIONS 2 C RS CAME traffic barriers are a blend of design safety and security. The various models are designed for modular applications and the

More information

AUTOMATION WITH PRATICO SYSTEM FOR SLIDING GATES BX SERIES INSTALLATION MANUAL BX-P

AUTOMATION WITH PRATICO SYSTEM FOR SLIDING GATES BX SERIES INSTALLATION MANUAL BX-P AUTOMATION WITH PRATICO SYSTEM FOR SLIDING GATES BX SERIES INSTALLATION MANUAL BX-P IMPORTANT SAFETY INSTRUCTIONS FOR INSTALLATION CAUTION: IMPROPER INSTALLATION MAY CAUSE SERIOUS DAMAGE, FOLLOW ALL INSTALLATION

More information

F ERNI K I T THE FERNI-S KIT CONSISTS OF:

F ERNI K I T THE FERNI-S KIT CONSISTS OF: CAME UNITED KINGDOM LTD ORCHARD PARK INDUSTRIAL ESTATE TOWN STREET, SANDIACRE, NOTTINGHAM, NG10 5BP TEL: 0115 921 0430 FAX: 0115 921 0431 INTERNET - www.cameuk.com E-MAIL - enquiries@cameuk.com TECHNICAL

More information

AUTOMATION WITH PRATICO SYSTEM FOR SLIDING GATES BK SERIES INSTALLATION MANUAL BK-1200P

AUTOMATION WITH PRATICO SYSTEM FOR SLIDING GATES BK SERIES INSTALLATION MANUAL BK-1200P AUTOMATION WITH PRATICO SYSTEM FOR SLIDING GATES BK SERIES INSTALLATION MANUAL BK-100P IMPORTANT SAFETY INSTRUCTIONS FOR INSTALLATION CAUTION: IMPROPER INSTALLATION MAY CAUSE SERIOUS DAMAGE, FOLLOW ALL

More information

TRAFFIC BARRIERS COST EFFECTIVE BARRIER SOLUTIONS

TRAFFIC BARRIERS COST EFFECTIVE BARRIER SOLUTIONS TRAFFIC BARRIERS COST EFFECTIVE BARRIER SOLUTIONS The range extends from 2.75m up to 12m (the biggest in the market) and with opening speed up to 0.9s and are all designed for intensive duty cycle. All

More information

Installation manual ASTER AUTOMATION FOR SWING GATES 11_16

Installation manual ASTER AUTOMATION FOR SWING GATES 11_16 Installation manual ASTER AUTOMATION FOR SWING GATES 11_16 Contents 1. GENERAL SAFETY PRECAUTIONS... page 01 2. INTENDED USE AND APPLICATION... page 01 2.1 Kit contents... page 01 2.2 Technical features...

More information

Ditec PWR25H/35H Automation for hinged gates

Ditec PWR25H/35H Automation for hinged gates Ditec PWR25H/35H Automation for hinged gates (translation of the original instructions) www.entrematic.com IP2250EN Technical Manual Contents Subject Page 1. General safety precautions 27 2. Declaration

More information

FROG KIT. Installation Instructions for a Pair of gates... TECHNICAL HELPLINE THE FROG-P KIT CONSISTS OF:

FROG KIT. Installation Instructions for a Pair of gates... TECHNICAL HELPLINE THE FROG-P KIT CONSISTS OF: CAME UNITED KINGDOM LTD UNIT 3 ORCHARD PARK INDUSTRIAL ESTATE, TOWN STREET, SANDIACRE, NOTTINGHAM NG10 5BP TEL: 0115 921 0430 FAX: 0115 921 0431 TECHNICAL HELPLINE 0115 921 0430 INTERNET - www.cameuk.com

More information

AUTOMATION FOR SLIDING GATES INSTALLATION MANUAL BK BKE

AUTOMATION FOR SLIDING GATES INSTALLATION MANUAL BK BKE AUTOMATION FOR SLIDING GATES BK INSTALLATION MANUAL BK 800-1200 - 1800-2200 BKE 1200-1800 - 2200 IMPORTANT SAFETY INSTRUCTIONS FOR INSTALLATION CAUTION: IMPROPER INSTALLATION MAY CAUSE SERIOUS DAMAGE,

More information

unipark Parking space saver operator for single CAR space. Gearmotors 24 V DC

unipark Parking space saver operator for single CAR space. Gearmotors 24 V DC unipark Parking space saver operator for single CAR space. Gearmotors 24 V DC 1 1 Control panel 2 UNIP+ARK1 2 3 Max distance from the loop to the UNIPARK 2 m 3 guaranteed parking, with Unipark. Ideal for

More information

Istruzioni, instructions. Motoriduttore a braccio snodato per cancelli battenti Gear motor with articulated arm for swing gates ALPHEO

Istruzioni, instructions. Motoriduttore a braccio snodato per cancelli battenti Gear motor with articulated arm for swing gates ALPHEO Istruzioni, instructions Motoriduttore a braccio snodato per cancelli battenti Gear motor with articulated arm for swing gates ALPHEO 1 Istruzioni, instructions Attention! This manual is for qualified

More information

D Vers. 03 ELECTROMECHANICAL AUTOMATION FOR SWING GATES

D Vers. 03 ELECTROMECHANICAL AUTOMATION FOR SWING GATES E5 D811007 15-09-99 Vers. 03 ELECTROMECHANICAL AUTOMATION FOR SWING GATES 122 This product complies with recognised technical standards and safety regulations. We declare that this product is in conformity

More information

Amico. new. Above ground operator for swing gates of up to 1.8 m per gate leaf. A new concept in safety

Amico. new. Above ground operator for swing gates of up to 1.8 m per gate leaf. A new concept in safety Above ground operator for swing gates of up to 1.8 m per gate leaf Gate operators tested in compliance with European Standards on the subject of impact force new Amico A new concept in safety Amico is

More information

SUBWING 700 USER S AND INSTALLER S MANUAL V1.0 REV. 04/2017

SUBWING 700 USER S AND INSTALLER S MANUAL V1.0 REV. 04/2017 SUBWING 700 USER S AND INSTALLER S MANUAL V1.0 REV. 04/2017 00. CONTT 01. SAFETY INSTRUCTIONS INDEX 01. SAFETY INSTRUCTIONS STANDARDS TO FOLLOW 02. OPERATOR CONNECTION SCHEME INSTALLATION MAP TECHNICAL

More information

Myto BELOWGROUND AND ABOVEGROUND OPERATOR FOR SWING GATES

Myto BELOWGROUND AND ABOVEGROUND OPERATOR FOR SWING GATES Myto BELOWGROUND AND ABOVEGROUND OPERATOR FOR SWING GATES Myto The operator is out-of-sight while ease of installation and functionality surface. Came presents Myto, the new and easy belowground solution.

More information

STREET BARRIER AUTOMATION 119G25EN INSTALLATION MANUAL G G G4000N. English

STREET BARRIER AUTOMATION 119G25EN INSTALLATION MANUAL G G G4000N. English 119G25EN STREET BARRIER AUTOMATION INSTALLATION MANUAL G4000 - G4001 - G4000N English EN Foreword Use of the products must be restricted to its intended use (i.e. that for which it was expressly built

More information

GARD G6000. Installation Instructions for swift road barriers TECHNICAL HELPLINE THE GARD KIT CONSISTS OF:

GARD G6000. Installation Instructions for swift road barriers TECHNICAL HELPLINE THE GARD KIT CONSISTS OF: CAME UNITED KINGDOM LTD UNIT 3 ORCHARD PARK INDUSTRIAL ESTATE, TOWN STREET, SANDIACRE, NOTTINGHAM NG10 5BP TEL: 0115 921 0430 FAX: 0115 921 0431 TECHNICAL HELPLINE 0115 921 0430 INTERNET - www.cameuk.com

More information

BULL 424 ESA BULL 624 ESA

BULL 424 ESA BULL 624 ESA L8542677 01/2012 rev 1 BULL 424 ESA BULL 624 ESA UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI 1 140 260 92 83 330 330 210 326 2 X BULL.P3 34 mm = = 3 3 4 P P D 102 mm

More information

Ditec QIK80EH Electromechanical barrier. IP2085EN Technical Manual. (Original instructions)

Ditec QIK80EH Electromechanical barrier. IP2085EN Technical Manual. (Original instructions) Ditec QIK80EH Electromechanical barrier (Original instructions) IP2085EN Technical Manual www.ditecentrematic.com 2 Index Subject Page 1. General safety precautions 4 2. EC Declaration of Conformity 5

More information

EC DECLARATION OF CONFORMITY FOR MACHINES (DIRECTIVE 98/37/EC) WARNINGS FOR THE INSTALLER

EC DECLARATION OF CONFORMITY FOR MACHINES (DIRECTIVE 98/37/EC) WARNINGS FOR THE INSTALLER EC DECLARATION OF CONFORMITY FOR MACHINES (DIRECTIVE 98/37/EC) Manufacturer: Address: Declares that: FAAC S.p.A. Via Benini, 1-40069 Zola Predosa BOLOGNA - ITALY 740-24V mod. operator is built to be integrated

More information

Ditec PWR50H/HV/HR Automation for swing gates

Ditec PWR50H/HV/HR Automation for swing gates Ditec PWR50H/HV/HR Automation for swing gates (translation of the original instructions) IP2253EN Technical Manual www.entrematic.com Contents Subject Page 1. General safety precautions 23 2. Declaration

More information

SWING GATE OPENERS 24V DC GEAR MOTOR

SWING GATE OPENERS 24V DC GEAR MOTOR SWING GATE OPENERS 24V DC GEAR MOTOR FOR RESIDENTIAL USER MANUAL Flashing Light Push Button Control box Gate 2 Gate 1 Index 1. Warnings 2 4. Technical Characteristics 16 2. Product Description 2.1 Applications

More information

AUTOMATION FOR SWING GATES 119D49EN INSTALLATION MANUAL A 3000/3006/3100/3106 A 5000/5006/5100/5106. English

AUTOMATION FOR SWING GATES 119D49EN INSTALLATION MANUAL A 3000/3006/3100/3106 A 5000/5006/5100/5106. English 119D49EN AUTOMATION FOR SWING GATES INSTALLATION MANUAL A 3000/3006/3100/3106 A 5000/5006/5100/5106 English EN 4 x 1,5 WARNING! important safety instructions: READ CAREFULLY! Introduction Use this product

More information

24 V ENCODER SAFE VERSATILE SETTING. Ditec Qik Automatic barriers for passages up to 7.6 m.

24 V ENCODER SAFE VERSATILE SETTING. Ditec Qik Automatic barriers for passages up to 7.6 m. SAFE 24 V ENCODER VERSATILE SETTING EN Ditec Qik Automatic barriers for passages up to 7.6 m www.entrematic.com Ditec Qik Ditec Qik is the top performance automatic barrier that fits perfectly into any

More information

BARRY BARRIER GATE AUTOMATION

BARRY BARRIER GATE AUTOMATION BARRY BARRIER GATE AUTOMATION Installation Manual 1. WARNINGS AND GENERAL SAFETY INSTUCTIONS This manual contains important safety information. An incorrect installation or an improper use may cause serious

More information

Owner s Manual. For SOLAR BOOM GATE. Model: CA-5000 SOLAR

Owner s Manual. For SOLAR BOOM GATE. Model: CA-5000 SOLAR ECA Electronic Engineering Pty. LTD. Australia Tel: 03-95720 535 Fax: 95 720 536 Owner s Manual For SOLAR BOOM GATE Model: CA-5000 SOLAR ( 2009 / Version 1 ) 1 1 Introduction 1.0 Control PCB Wiring INSTALLATION

More information

PW320/PW330 USER MANUAL SWING GATE OPENERS 24V DC GEAR MOTOR FOR RESIDENTIAL. Flashing Light. Push Button. Control box. Gate 2.

PW320/PW330 USER MANUAL SWING GATE OPENERS 24V DC GEAR MOTOR FOR RESIDENTIAL. Flashing Light. Push Button. Control box. Gate 2. PW320/PW330 USER MANUAL SWING GATE OPENERS 24V DC GEAR MOTOR FOR RESIDENTIAL Flashing Light Push Button Control box Gate 2 Gate 1 Declaration of Conformity Applicant: Powertech Electronics Inc. Manufacturer:

More information

PW150/PW200 USER MANUAL SWING GATE OPENERS 24V DC GEAR MOTOR

PW150/PW200 USER MANUAL SWING GATE OPENERS 24V DC GEAR MOTOR PW150/PW200 USER MANUAL SWING GATE OPENERS 24V DC GEAR MOTOR FOR RESIDENTIAL Flashing Light Push Button Control box Declaration of Conformity Applicant: Powertech Electronics Inc. Manufacturer: Timotion

More information

E R A I GATE AUTOMATION DIVISION

E R A I GATE AUTOMATION DIVISION S E R A I GATE AUTOMATION DIVISION INSTALLATION MANUAL MC/5C - 03.5C UNDERGROUND MOTOR 230 Vac FOR WING GATES UP TO 3,00m AND 300 Kg EACH WING + FOUNDATION BOX IN HOT-GALVANISED STEEL Thank you for choosing

More information

Instructions manual. Below ground oil-hydraulic operator for swinging gates. pages 17-32

Instructions manual. Below ground oil-hydraulic operator for swinging gates. pages 17-32 Below ground oil-hydraulic operator for swinging gates STANDARD VERSION: 110 or 17 Leaf Rotation Compact, internal drive unit and hydraulic jack Normal version or version with two-way Locking device Models

More information

L /2013 rev 0 BISON 35 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

L /2013 rev 0 BISON 35 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI L8543019 04/2013 rev 0 BISON 35 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI 1 458 250 A F 645 477 B 195 470 270 2 C 13 ±5 156 70 2 3 4 D2 R D2 I D1 T 5 W D H G R

More information

E R A I Gate Openers Department

E R A I Gate Openers Department S E R A I Gate Openers Department INSTALLER MANUAL KIT/46 84.46 SOLAR POWERED KIT TO CONTROL ONE 4 VDC PROPERTY PARKING RESERVATION MOTOR Thank you for having chosen SERAI ELETTRONICA, certain that you

More information

TECHNICAL DATA HYDRAULIC UNIT

TECHNICAL DATA HYDRAULIC UNIT GB INSTRUCTIONS MANUAL RISING BOLLARD OIL-HYDRAULIC AUTOMATION COMPONENTS strabuc 918 RELEASE KEY PLUG FOR RELEASE HOLE BOLLARD COVER 12 V WARNING LIGHTS REFLECTORS COMPLETELY RETRACTABLE POST WITH ELECTROPHORESIS

More information

V. 003 QUESTO LIBRETTO È DESTINATO SOLO ALL'INSTALLATORE.

V. 003 QUESTO LIBRETTO È DESTINATO SOLO ALL'INSTALLATORE. V. 003 QUESTO LIBRETTO È DESTINATO SOLO ALL'INSTALLATORE. L'installazione dovrà essere effettuata solamente da personale professionalmente qualificato in conformità a quanto previsto dalla legge n 46 del

More information

AUTOMATION FOR SECTIONAL AND OVERHEAD GARAGE DOORS 119ES87EN INSTALLATION MANUAL V700. English

AUTOMATION FOR SECTIONAL AND OVERHEAD GARAGE DOORS 119ES87EN INSTALLATION MANUAL V700. English 119ES87EN AUTOMATION FOR SECTIONAL AND OVERHEAD GARAGE DOORS INSTALLATION MANUAL V700 English EN Foreword Use of the products must be restricted to its intended use (i.e. that for which it was expressly

More information

Ditec LUXO Swing gates automation (Original instruction)

Ditec LUXO Swing gates automation (Original instruction) Ditec LUXO Swing gates automation (Original instruction) IP2128EN Technical manual www.ditecentrematic.com Index Subject Page 1. General safety precautions 21 2. Declaration of incorporation of partly

More information

UNDERGROUND OPERATOR FOR SWINGING GATES. WARNING!! Before installing, thoroughly read this manual that is an integral part of the pack

UNDERGROUND OPERATOR FOR SWINGING GATES. WARNING!! Before installing, thoroughly read this manual that is an integral part of the pack UNDERGROUND OPERATOR FOR SWINGING GATES COMPAS 2 WARNING!! Before installing, thoroughly read this manual that is an integral part of the pack Our products if installed by qualified personnel capable to

More information

SLIDE & OL USER'S AND INSTALLER'S MANUAL V1.0 REV. 06/2017

SLIDE & OL USER'S AND INSTALLER'S MANUAL V1.0 REV. 06/2017 SLIDE & OL USER'S AND INSTALLER'S MANUAL V1.0 REV. 06/2017 00. CONTT 01. SAFETY INSTRUCTIONS INDEX 01. SAFETY INSTRUCTIONS STANDARDS TO FOLLOW 02. OPERATOR TECHNICAL SPECIFICATIONS DESCRIPTION DIMSIONS

More information

BISON 20 OM BISON 25 OTI

BISON 20 OM BISON 25 OTI L8542939 11/2011 rev 0 BISON 20 OM BISON 25 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI 2 x 1,5 GND 13 8 7 5 RG 58 4 3 4 x 0,35 6 1 2 4 3 x 1,5 min 230V 2 x 0,35

More information

Ditec QIK4E-7EH-7YEH Electromechanical barrier (Original instructions)

Ditec QIK4E-7EH-7YEH Electromechanical barrier (Original instructions) Ditec QIK4E-7EH-7YEH Electromechanical barrier (Original instructions) IP1861EN Technical Manual www.ditecentrematic.com 24 Index Key Subject 1. General safety precautions 26 2. EC Declaration of Conformity

More information

Installation manual. English. mystrike OPENER FOR RACK-DRIVEN SLIDING MOTOR

Installation manual. English. mystrike OPENER FOR RACK-DRIVEN SLIDING MOTOR Installation manual English mystrike OPENER FOR RACK-DRIVEN SLIDING MOTOR 1. WARNINGS AND GENERAL SAFETY INSTRUCTIONS This manual contains important safety information. An incorrect installation or an

More information

BAYT 980. Oil-hydraulic OIL-HYDRAULIC BARRIER FOR TRAFFIC CONTROL INSTALLATION MANUAL. code 4425 Post with fixing base. POLO 44 - optional -

BAYT 980. Oil-hydraulic OIL-HYDRAULIC BARRIER FOR TRAFFIC CONTROL INSTALLATION MANUAL. code 4425 Post with fixing base. POLO 44 - optional - Oleodinamica BAYT 980 Oil-hydraulic OIL-HYDRAULIC BARRIER FOR TRAFFIC CONTROL POLO 44 - optional - BAYT 980 560 code 4425 Post with fixing base the gate opener Made in Italy INSTALLATION MANUAL GB INSTRUCTIONS

More information

SLIDE NEW CONTROL BOARD

SLIDE NEW CONTROL BOARD GB SLIDE NEW CONTROL BOARD CN1 CN2 3 4 5 FUSE 2 RL2 RL1 FUSE 1 TR2 TR1 TR3 TR4 U 1 JP1 Ld2 CMR 3 4 CN E Ld7 Ld6 Ld5Ld4Ld3 CN3 3 4 5 6 7 8 9 10 11 SW 12 13 14 Ld1 P2 P1 FUSE 1 FUSE 2 TR1 TR2 TR3 TR4 SW.1

More information

OPERATOR SHAFT-120. Installation and Operating Manual CONTENTS GENERAL INFORMATION SAFETY INSTRUCTIONS OPERATOR UNIT OPERATOR INSTALLATION

OPERATOR SHAFT-120. Installation and Operating Manual CONTENTS GENERAL INFORMATION SAFETY INSTRUCTIONS OPERATOR UNIT OPERATOR INSTALLATION OPERATOR CONTENTS GENERAL INFORMATION SAFETY INSTRUCTIONS OPERATOR UNIT OPERATOR INSTALLATION ELECTRICAL CONNECTIONS ADJUSTMENT OF EXTREME POSITIONS OPERATOR PROGRAMMING RELEASE OPERATION MAINTENANCE TROUBLE

More information

MBM8 / MBM11- Barriers. Installer and User s manual

MBM8 / MBM11- Barriers. Installer and User s manual MBM8 / MBM11- Barriers Installer and User s manual v2.0 REV. 01/2014 00. CONTENT 01.SAFETY INSTRUCTIONS INDEX 00. CONTENT index page 01.A 01. SAFETY INSTRUCTIONS standards to follow page 01.B 02. PACKAGE

More information

SWING GATE OPENERS 24V DC GEAR MOTOR

SWING GATE OPENERS 24V DC GEAR MOTOR SWING GATE OPENERS 24V DC GEAR MOTOR FOR RESIDENTIAL USER MANUAL Flashing Light Push Button Control box Gate 2 Gate 1 Index Warnings 2 5. Technical Characteristics 21 1. Product Description and Applications

More information

contents OPERATOR Maintenance SHAFT-120 Installation and Operating Manual DoorHan, 2012

contents OPERATOR Maintenance SHAFT-120 Installation and Operating Manual DoorHan, 2012 OPERATOR contents General Information Safety instructions Operator unit operator Installation Electrical Connections adjustment of extreme positions operator programming Release operation Maintenance Trouble

More information

E R A I Gate Automation Division

E R A I Gate Automation Division S E R A I Gate Automation Division INSTALLATI MANUAL SR 24.39 CTROL UNIT TO COMMAND 1 OR 2 12/24Vdc MOTORS FOR THE AUTOMATI OF SWING GATES Thank you for choosing a SERAI ELETTRICA product, which we are

More information

access

access 184 Table of Contents Access Garage door Motors Dexxo Pro 800 RTS... 188 Dexxo Pro 1000 RTS... 189 Dexxo Optimo RTS... 190 Receiver Axroll NS... 191 Freeroll ESE RTS, RTS receiver for roller garage doors...

More information

INSTALLER AND USER S MANUAL. v4.0 REV. 01/2019

INSTALLER AND USER S MANUAL. v4.0 REV. 01/2019 MBM6 -BARRIER INSTALLER AND USER S MANUAL v4.0 REV. 01/2019 00. CONTT INDEX 01. SAFETY INSTRUCTIONS STANDARDS TO FOLLOW 01. SAFETY INSTRUCTIONS STANDARDS TO FOLLOW 02. PACKAGE INSIDE PACKAGE 03. OPERATOR

More information

Porte 150 Users Manual Swing Gate Opener 24V DC

Porte 150 Users Manual Swing Gate Opener 24V DC Porte 150 Users Manual Swing Gate Opener 24V DC for residential use only Signal Light Push-button Control Box 14 Contents 1. Important Safety Information 2. Product Description and Application 2.1 Application

More information

INSTALLATION MANUAL ACE. Gearmotor for swing gates 01_17

INSTALLATION MANUAL ACE. Gearmotor for swing gates 01_17 INSTLLTION MNUL E Gearmotor for swing gates 0_7 Index. SFETY INSTRUTIONS... pag. 0 OMPLINE DELRTION... pag. 0 2. DESRIPTION ND INTENDED USE... pag. 0 2. Technical data... pag. 02 2.2 Kit content... pag.

More information

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION EC MACHINE DIRECTIVE COMPLIANCE DECLARATION (DIRECTIVE 89/392 EEC, APPENDIX II, PART B) Manufacturer: FAAC S.p.A. Address: Via Benini, 1 40069 - Zola Predosa BOLOGNA - ITALY Hereby declares that: the 770

More information

DESIGNED FOR RESIDENTIAL APPLICATION KIT PL600/PL1000 SLIDING GATE OPENERS

DESIGNED FOR RESIDENTIAL APPLICATION KIT PL600/PL1000 SLIDING GATE OPENERS SLIDING GATE OPENER DESIGNED FOR RESIDENTIAL APPLICATION KIT PL600/PL1000 SLIDING GATE OPENERS The strongest solution for sliding gates PL600/PL1000 electro-mechanical sliding gate openers are designed

More information

GROUND GROUND - ( ) Interrati elettromeccanici ISTRUZIONI PER L INSTALLAZIONE. Electromechanical underground INSTRUCTIONS FOR INSTALLATIONS

GROUND GROUND - ( ) Interrati elettromeccanici ISTRUZIONI PER L INSTALLAZIONE. Electromechanical underground INSTRUCTIONS FOR INSTALLATIONS GROUND GROUND - (610-624) Interrati elettromeccanici ISTRUZIONI PER L INSTALLAZIONE Electromechanical underground INSTRUCTIONS FOR INSTALLATIONS I UK F E D P NL GR 2 GROUND 1a 6 3 4 7 Ø 5 x4 3 9 1 8 1

More information

Automation systems for swing gates hydraulic

Automation systems for swing gates hydraulic 70 Automation systems for swing gates hydraulic A wide range of operators designed to respond to the multiple needs of swing gates. BFT automation systems are suitable for any type of gate - heavy, light,

More information

MEKO OPENER FOR RACK-DRIVEN SLIDING MOTOR

MEKO OPENER FOR RACK-DRIVEN SLIDING MOTOR Installation Manual MEKO OPENER FOR RACK-DRIVEN SLIDING MOTOR 02_2016 1. WARNINGS AND GENERAL SAFETY INSTUCTIONS This manual contains important safety information. An incorrect installation or an improper

More information

IRREVERSIBLE OPERATOR FOR SWING GATES AND DOORS

IRREVERSIBLE OPERATOR FOR SWING GATES AND DOORS VH IRREVERSIBLE OPERATOR FOR SWING GATES AND DOORS WARNING!! Before installing, thoroughly read this manual that is an integral part of the pack Our products if installed by qualified personnel capable

More information

INSPECTIONS AND MAINTENANCE

INSPECTIONS AND MAINTENANCE GB INSTRUCTIONS MANUAL STRABUC 930 ARMOURED OIL-HYDRAULIC RISING BOLLARD COMPONENTS strabuc 930 RELEASE KEY PROTECTION PLUG TO ACCESS RELEASE HOLE BOLLARD COVER 12V WARNING LIGHTS REFLECTORS RISING POST

More information

Automations for garage doors and rolling shutters

Automations for garage doors and rolling shutters Automations for garage doors and rolling shutters Technology Versatility Low consumption BLINKO Flashing LED Technological solutions for safe operation All V2 operators for garage doors allow: - Precise

More information

L /2012 rev 0 BISON 30 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

L /2012 rev 0 BISON 30 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI L8542968 07/2012 rev 0 BISON 30 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI 1 458 250 A F 645 477 B 195 470 270 2 C 13 ±5 156 70 2 3 4 D2 R D2 I D1 T 5 W D H G R

More information

Control panel installation manual for 230 V~ automation with one or two motors D5 S5 JT RF ON TC RP TR R1 OM J7. Electric lock. Flashing light.

Control panel installation manual for 230 V~ automation with one or two motors D5 S5 JT RF ON TC RP TR R1 OM J7. Electric lock. Flashing light. FUSE Ditec LOGIC M Control panel installation manual for 230 V~ automation with one or two motors IP1854EN LOGICM F2 FUSE JR4 JR10 SO D5 S5 JT NIO CT 1 2 3 4 5 RF ON AUX AUX F1 POWER SA IN 11 12 TM JR6

More information

INSTRUCTIONS FOR INSTALLATION

INSTRUCTIONS FOR INSTALLATION HYDRAULIC OPERATOR MODO 110-110/L FOR SINGLE- OR DOUBLE-WING SWING GATES INSTRUCTIONS FOR INSTALLATION GENERAL WARNINGS These warnings constitute an integral and essential part of the product and must

More information

FEATURES AND SPECIFICATIONS

FEATURES AND SPECIFICATIONS FEATURES AND SPECIFICATIONS The is a high quality hydraulic operator for residential and condominium use with leaf length up to 3 m. Available in the following versions: AC (with lock in opening and closing)

More information

BULL 5M - BULL 5M.S BULL 8M - BULL 8 M.S BULL 8 OM - BULL 8 OM.S

BULL 5M - BULL 5M.S BULL 8M - BULL 8 M.S BULL 8 OM - BULL 8 OM.S L8542676 04/2012 rev. 2 BULL 5M - BULL 5M.S BULL 8M - BULL 8 M.S BULL 8 OM - BULL 8 OM.S UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI 1 140 260 100 91 330 330 210 326

More information

SKC400U SLIDING GATE OPENER OWNER S MANUAL

SKC400U SLIDING GATE OPENER OWNER S MANUAL SKC400U SLIDING GATE OPENER OWNER S MANUAL IMPORTANT SAFTEY INFORMATION Installing the SKC400U Gate Opener requires wiring of standard 110V electrical lines. This should only be performed by a trained

More information

TITANO 400V SLIDING GATE OPENER

TITANO 400V SLIDING GATE OPENER TITANO 400V SLIDING GATE OPENER USE AND MAINTENANCE MANUAL V07 /2018 TECHNICAL FEATURES א א א א QK-T3000 QK-T4000 QK-T6000 (VAC) 400 Three Phase א א א א (W) 700 750 1500 א א א א (A) 1,7 2,2 3,7 א א C -30/+70

More information

CE DECLARATION OF MACHINE CONFORMITY

CE DECLARATION OF MACHINE CONFORMITY CE DECLARATION OF MACHINE CONFORMITY (DIRECTIVE 2006/42/EC) Manufacturer : Address: Declares that: FAAC S.p.A. Via Calari, 10-40069 Zola Predosa BOLOGNA - ITALY Operator mod. 541 3ph is built to be incorporated

More information

INSTALLATION M ANUAL

INSTALLATION M ANUAL INSTALLATION MANUAL Table of Contents UL Listings Installing the Warning Sign / Precautions Methods of Installation / Compact Installation Mounting the Secondary Entrapment / Welding Gate Arn Mounting

More information

INSTALLATION MANUAL FOR SWING SHUTTERS KAF212. FACE S.r.l. Viale delle Industrie, Dosson di Casier Treviso Italy

INSTALLATION MANUAL FOR SWING SHUTTERS KAF212. FACE S.r.l. Viale delle Industrie, Dosson di Casier Treviso Italy INSTALLATION MANUAL FOR SWING SHUTTERS KAF212 FACE S.r.l. Viale delle Industrie, 74 31030 Dosson di Casier Treviso Italy INDEX Subject Page 1. General safety instruction 2 1.1 EC marking and European directives

More information

MOUNTING AND CONNECTING INSTRUCTIONS 1. GATE ARRANGEMENT ENGLISH

MOUNTING AND CONNECTING INSTRUCTIONS 1. GATE ARRANGEMENT ENGLISH SATURN SATURN is a motor reducer designed for the automation of sliding gates with grease lubrication of the gear in the 600 version; in oil bath in the 1000 and 2000 versions. The irreversibility of the

More information

1 GENERAL SAFETY PRECAUTIONS

1 GENERAL SAFETY PRECAUTIONS 16EN 16 1 GENERAL SAFETY PRECAUTIONS Failure to respect the information given in this manual may cause personal injury or damage to the device. This installation manual is intended for qualified personnel

More information

Ditec EL31R Installation Manual for control panel for 24V automations with built-in radio.

Ditec EL31R Installation Manual for control panel for 24V automations with built-in radio. Ditec EL31R Installation Manual for control panel for 24V automations with built-in radio. IP1851EN Motor 24V= EL31R -M +M ENC A N T AT IN 11 JR1 ATK3 SA POWER 12 COM AUX SIG PRG Safety switch A 1 1 2

More information

IP2160 EN. Ditec NEOS Sliding Gates. Technical Manual. (Original instructions)

IP2160 EN. Ditec NEOS Sliding Gates. Technical Manual. (Original instructions) Ditec NEOS Sliding Gates (Original instructions) IP2160 EN Technical Manual www.ditecentrematic.com Index Subject Page 1. General safety precautions 4 2. Declaration of incorporation of partly completed

More information

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN SYMBOL LEGEND DANGER THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN WARNING THIS WARNS THAT MATERIALS MAY BE DAMAGED IF APPROPRIATE PRECAUTIONS ARE NOT

More information

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION 770 EC MACHINE DIRECTIVE COMPLIANCE DECLARATION (DIRECTIVE 89/392 EEC, APPENDIX II, PART B) Manufacturer: FAAC S.p.A. Address: Via Benini, 1 40069 - Zola Predosa BOLOGNA - ITALY Hereby declares that: the

More information