KSA/KSB ACCESSORIES ELECTRICAL ACCESSORIES MECHANICAL ACCESSORIES
|
|
- Willis Mitchell
- 6 years ago
- Views:
Transcription
1 KSA/KSB ACCESSORIES ELECTRICAL ACCESSORIES Plunger Style Door Switch (Suitable for all pilot duty control or unit control based on number of motors and voltage: KSA: 120V or KSB: 120V or V) Roller Arm Door Switch (Suitable for all pilot duty control or unit control based on number of motors and voltage: KSA: 120V or KSB: 120V or V) Remote Hand/Off/Auto Selector Switch (Single phase only) 1½ 120V, V Toggle Disconnect Remote Mounted 30 amp V, Single Phase (2 hp max.) Toggle Disconnect Unit Mounted 30 amp V, Single Phase (2 hp max.) Thermostat 2-Pole 9505T C C-BI 9502DS2T-P Remote Mounted 9502DS2T-P-BI Unit Mounted Locking Cover For Thermostat 95022E999 MECHANICAL ACCESSORIES Correctional Tamper Proof Package Wall Support Bracket Two Required Per Unit Add Suffix -TP to MODEL# Example: KSA2072AA-TP VS-000WMB VS-000WMB Extension Bracket (Not Available for Electric Heated Units or Units with a factory mounted motor control) 12 Extension Bracket (Not Available for Electric Heated Units or Units with a factory mounted motor control) Floor Mounting Bracket (Two Piece) Tandem Mounted Bracket Maximum Joined Length-Vertical 30 66VS-006EB 66VS-012EB 66VS-000FMB 66VS-000TMB 1
2 KSA/KSB ACCESSORIES 1/2 ALUMINUM & POLYWASHABLE FILTERS FOR UNHEATED, ELECTRIC, STEAM & HOT WATER HEATED UNITS FILTER LENGTH CONTROL STATIONS SINGLE PHASE CONTROL STATIONS - UNHEATED MODELS ONLY Note:1. Single phase control stations listed below are required when: The motor quantities exceed the following: KSA: 120V or V; KSB: 120V or V UNHEATED MODELS ONLY 2. If the motor quantities at voltage do not exceed the requirements as stated in #1 (above), a control station is not required and only a plunger or roller style door switch needs to be quoted. SINGLE PHASE CONTROL STATION COMPONENTS - Line Voltage Control Factory mounted/wired NEMA & 12 rated industrial enclosure (standard right hand end plate, left hand optional), motor contactor, fusing (when required) & terminal strip. Single Phase Control Station - Factory Mounted Right End UNHEATED # of MOTORS VOLTAGE hp. PART # ALUMINUM FILTER 9012CS0A3P120 POLYWASHABLE FILTER 36 80VS-036C-A 80VS-036C 2 80VS-02C-A 80VS-02C 8 80VS-08C-A 80VS-08C 60 80VS-060C-A 80VS-060C 72 80VS-072C-A 80VS-072C 78 80VS-078C-A 80VS-078C 8 80VS-08C-A 80VS-08C 96 80VS-096C-A 80VS-096C VS-108C-A 80VS-108C VS-120C-A 80VS-120C VS-132C-A 80VS-132C 1 80VS-1C-A 80VS-1C Note: Polywashable filter cannnot be used on UL certified unheated and electric units *FILTER REPLACES PERFORATED INTAKE GRILLE Consult factory for cost of filter with perforated intake grille 120 KSA 1/2 9012CFDA1A1F CFDA1B1F CFDA1J1F CS0A3P CS0A3P KSB CFDA1A CFDA1B CFDA1J001 2
3 OPTIONAL SINGLE PHASE CONTROL STATION ACCESSORIES All optional accessories will be factory mounted/wired inside the control station KSA/KSB UNHEATED MODELS ONLY CONTROL STATIONS CONTROL STATION ACCESSORIES Time Delay-Line Voltage Control (120/208/20/1) Add -TD to part # Time Delay- 2 Volt Control (includes time delay and transformer) Add -2-TD to part # 2 Volt Control Add -2 to part # ELECTRICALLY HEATED MODELS ONLY CONTROL PACKAGES BASIC CONTROL PACKAGE Recommended for openings where the door stays open or does not have a lot of traffic. Includes: Door Switch Plunger Style, Roller Style, or Magnetic Reed Style 2 VOLT CONTROL PACKAGE Basic Plunger Basic Roller Basic Magnetic 9503MRS1F2-NC-K NOTE: If there are multiple manual doors on the opening, an additional switch is required. Includes: Door Switch Plunger Style, Roller Style, Magnetic Reed Style Factory Installed Time Delay Relay DELUXE CONTROL PACKAGE Recommended for high traffic openings. 2 VOLT CONTROL PACKAGE Deluxe Plunger 2 V Deluxe Roller 2 V Deluxe Magnetic Reed 2 V 91VSA120-DE-P 91VSA120-DE-R 91VSA120-DE-M NOTE: If there are multiple manual doors on the opening, an additional switch is required. 3
4 Control Panel Required for all motors operating on three phase power NOT NEEDED FOR ELECTRICALLY HEATED MODELS Standard Features NEMA /12 Enclosure Motor Contactor Motor Overload (one per motor) 120V Control Transformer Terminal Strip Optional NEMA X Enclosure Features Poly Fiberglass Aluminum Stainless Steel Optional Feature 2V control Transformer NOTE: A switch (door switch, manual start/stop, etc.) must be ordered with the panel for activation of the unit(s) V 80V REMOTE or FACTORY MOUNTED REMOTE or FACTORY MOUNTED 1/2 or 1 hp 1/2 or 1 hp 1/2 or 1 hp 1/2 or 1 hp 1/2 or 1 hp 1/2 or 1 1/2 or 1 or 1 hp CONTROL PANEL PART NUMBER CONFIGURATION 903BA1HAF001-FD Phase 3= Three # of Motors A = 1 B = 2 C = 3 D = Heat Code A = Unheated Speed 1 = Single Speed Voltage Code D = 208/3/60 E = 20/3/60 H = 80/3/60 T - 380/3/50 Model AF = KSA/KSB HP 1/2 = 1F2 1 = 001 Disconnect FD=Fused ND=Nonfused Optional
5 For: Unheated & Electrically Heated Models Control Panel Accessories Hand/Off/Automatic Switch Start/Stop Push Button Station Non-Fused Disconnect Switch CONTROL PANEL ACCESSORIES - BUILT-IN 9505HOAB-CP 950SSPB-CP 3Ø V; 20 80V; 0 amps Add -ND to part # 3Ø V; 25 80V; 60 amps Add -ND to part # 3Ø V; 25 20V; amps Add -ND to part # 3Ø V; 0 20V; 75 80V; amps Add -ND to part # 3Ø V; 60 20V; V; amps Fused Disconnect Switch Add -ND to part # 3Ø V; 15 80V; 30 amps Add -FD to part # 3Ø V; 35 80V; 60 amps Add -FD to part # 3Ø V; 30 20V; amps Add -FD to part # 3Ø V; 0 20V; 75 80V; amps Add -FD to part # 3Ø V; 60 20V; V; amps Add -FD to part # Time Delay Relay (120V or 2V) 9009KOL312-C CONTROL PANEL ACCESSORIES - REMOTE MOUNTED Hand/Off/Automatic Switch 9505HOAR Start/Stop Push Button Station 950SSPBR Plunger Style Door Switch Roller Arm Door Switch Thermostat 2-Pole 9502DS2T-P Locking Cover For Thermostat 95022E999 5
ACCESSORIES & OPTIONS GUIDE
accessories-options 11b ML 10/4/13 ACCESSORIES & OPTIONS GUIDE 1 TABLE OF CONTENTS Door Limit Switches 3-5 Controllers 6 Motor Control Panels 7 Specialty Motors 8 Mounting Hardware 9 Filters 10 Special
More informationWAC Air Curtains Technical Guide
TGWAC-2 WAC Air Curtains Technical Guide FOR WIND STOPPING, INSECT CONTROL, AND ENVIRONMENTAL SEPARATION IN COMMERCIAL AND INDUSTRIAL APPLICATIONS TABLE OF CONTENTS Introduction......................................................................2
More informationSECTION MOTOR CONTROL
SECTION 26 24 19 MOTOR CONTROL PART 1 - GENERAL 1.1 SECTION INCLUDES A. Manual motor starters B. Magnetic motor starters C. Combination magnetic motor starters D. Solid-state reduced voltage motor starters
More informationCoil Data Nominal Current MA Nominal VA Sealed Single Pole Normally Open (SPNO) White Rodgers Q
14/03/08 A136 Relay - General Purpose 90-293Q Enclosed fan relays used for switching single or two speed fan motors, solenoids, relays, resistive loads, heating and cooling applications and general purpose
More informationNMC Combination Line Starters and Enclosures
NMC Combination Line Starters 600VAC Heavy uty atertight eatherproof Applications: NMC combination magnetic line starters are for use in across-the-line motor starting, motor disconnect, motor and line
More informationAF40... AF96 3-pole contactors Technical data
Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional
More informationComfort. Description. Applications
Blower Heater 3-35 kw 10,236-119,420 Btuh 208, 240, 480 and 575 Volt 1 or 3 Phase Built-in Controls Description Type is designed to heat areas classified as hazardous locations to provide primary or supplementary
More informationEnclosures for hazardous areas EBMX clamped enclosures. Clamped EBMX. NEMA 7 classifi ed enclosures
Enclosures for hazardous areas clamped enclosures Clamped NEMA 7 classifi ed enclosures Clamped : NEMA 7 classified enclosures Safer. Faster. Easy access, lower risk and less downtime. Creative thinking
More informationPanelboards & Motor Starters
Appleton s ATX series of Increased Safety distribution panels are available in IP66-rated fiberglass reinforced polyester (FRP) or 316L stainless steel and come in multiple sizes depending on the number
More informationComfort. Sewage Treatment Plants. Petrochemical Facilities, Oil Rigs. Unattended Pumping Stations. Chemical Storage and Handling Facilities
3-35 kw 10,200-119,420 Btuh 208 to 600 Volts 1 or 3 Phase Meets NEC, OSHA and UL Requirements ATEX and GOST Models Available Refer to WR-80EP in the Controls section. F-4 Description Type is designed to
More informationOpen Your Doors to Berner. Berner Industrial. The Nation s Original Air Door Manufacturer
Open Your Doors to Berner Berner Industrial AIR DOORS The Nation s Original Air Door Manufacturer 800-245-4455 www.airdoors.com how a berner air door works Activation Devices for Air Doors Plunger Style
More informationTRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 03/05/09 TSEWG TP-11: UFC N BEST PRACTICES
TSEWG TP-11: UFC 3-500-10N BEST PRACTICES UFC 3-500-10N was developed by NAVFAC and was used as the starting point for the tri-services development of UFC 3-500-10, Design: Electrical Engineering. UFC
More informationCerti 堵脝 cation Record
Certi 堵脝 cation Record Customer Schneider Electric USA, Inc. Square D Raleigh (Knightdale) Plant, 8001 Knightdale Blvd Knightdale NC USA 27545 Class 214 INDUSTRIAL CONTROL EQUIPMENTMotor Controllers Magnetic
More informationBasics of Control Components
Basics of Control Components Table of Contents Introduction...2 Electrical Symbols...6 Line Diagrams...16 Overload Protection...22 Overload Relays...26 Manual Control...35 Magnetic Contactors and Starters...41
More informationMERCURY TO METAL CONTACTORS AND RELAYS
MERCURY TO METAL CONTACTORS AND RELAYS DESCRIPTION MERCURY TO METAL CONTACTOR: The load terminals are isolated from each other by the glass in the hermetic seal. The plunger assembly, which includes the
More information800 T P B H 16 R. Momentary Contact Push Button Devices, Illuminated. 8 Rockwell Automation Publication 800-TD009A-EN-P
Momentary Contact Push utton Devices, Illuminated Extended Head Without Guard Cat. No. 800T-P16R Extended Head without Guard Cat. No. 800H-PR16R 800 T P H 16 R a Protection Rating T Metal, Type 4/13 H
More informationLPSRK30SP 30A 600V TD Dual Elem Class RK1 Low Peak Fuse
LPSRK30SP 30A 600V TD Dual Elem Class RK Low Peak Fuse Catalog Number Manufacturer Description Weight per unit Product Category LPSRK30SP 30A 600V Class RK Low Peak Dual Element, Time Delay Fuse 600 (lbs/each)
More informationLow-Peak 600V Class RK1
LPS-RK 600Vac/300Vdc, 1 10-60A, Dual Element, Time-Delay Fuses Dimensions - in 5" (± 0.31) 5.5" (± 0.31) Available with easyid open fuse indication 1/10 to 30A 0.81" (±0.008) 35 to 60A 1.06" (±0.008) Description:
More information800 T FX 1 A1. Color Cap. No cap 1 Green 2 Black 3 Orange 4 Grey 5 White 6 Red 7 Blue 9 Yellow. Contact Block(s) Operator Position.
NEM Push utton Specifications 800T/H 30.5 mm Push uttons 2-Position Push-Pull and Push-Pull/Twist Release Devices, Non-Illuminated Note: jumbo or large legend plate is recommended, if space allows. 2-Position
More informationLPSRK100SP 100A 600V TD Dual Elem Class RK1 Low Peak Fuse
LPSRK100SP 600V TD Dual Elem Class RK1 Low Peak Fuse Catalog Number Manufacturer Description Weight per unit Product Category LPSRK100SP 600V Class RK1 Low Peak Dual Element, Time Delay Fuse 0.4100 (lbs/each)
More informationAllen-Bradley 800T-FXD16RA1
NEM Push utton Specifications 800T/H 30.5 mm Push uttons 2-Position Push-Pull and Push-Pull/Twist Release Devices, Illuminated Note: jumbo or large legend plate is recommended, if space allows. Illuminated
More informationSensorless Vector Drives
STANDARD PRODUCTS Sensorless Vector Drives SG SERIES STANDARD DUTY / HEAVY DUTY RATINGS Variable Torque: 7.5 to 700HP @ 460V 7.5 to 40HP @ 2V Standard Duty: 7.5 to 600HP @ 460V 7.5 to 40HP @ 2V Heavy Duty:
More informationPlug and Play Kit Installation and Wiring (Non-Combo and Combo)
General Information This publication is to be used for Eaton Plug and Play enclosures designed starters that accept the M22 series 22mm cover control devices. To install the cover control kit (Follow the
More informationMagnetic Overload Relays
Magnetic Overload Relays Series N147 Series N147 Overload Relays are of the magnetically operated self reset type, designed for use on or motor starters and controllers for Navy Service A applications.
More informationHOW TO SPECIFY SDV UNITS
HOW TO SPECIFY SDV UNITS MODEL UNIT CONFIG LINER CASING OPTIONS CONST. SIDE INLET SIZE DISCHARGE OPTIONS CONTROL TYPE UNIT ACCESSORIES HEAT kw ELECTRIC HEAT ACCESSORIES SCR HEAT ACCESSORIES SDV 0 - Standard
More informationDefinite Purpose Contactors Types DP, DPA, and SYD Class 8910
s DP, DPA, and SYD Class 89 Compact Design Industry Standard Mounting Double Brea Contacts Low Coil VA Straight-Through Wiring Low Cost Definite purpose contactors are ideal for heating, air conditioning,
More informationMotors Automation Energy Transmission & Distribution Coatings. GPH2 Combination Soft Starters
Motors Automation Energy Transmission & Distribution Coatings GPH2 Combination Soft Starters GPH2 Combination Soft Starter 5to 350 HP The Combination Soft Starter is a NEMA 4/12 Enclosed industrial general
More informationCONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS
LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS I. SCOPE a. This specification describes the necessary requirements for the design, fabrication, and operation of automatically switched, low
More informationWash and rinse systems. Page 2. Various and air traps. Page 5. Drain and filter systems. Page 6. Door and hood components. Page 9
Wash and rinse systems Page Various and air traps Page 5 Drain and filter systems Page 6 Door and hood components Page 9 Electrical components Page 9 Dosing pumps Page Heating elements and boilers Page
More information3.1. NEMA Manual Starters. Contents Description Types B230, B330, Switches... MS Series, Single-Phase Starters...
Product Description The B100 Manual Motor Starters can be used in single-phase applications rated hp at 240 Vac or 2 hp at 20 Vdc. The starter can also be rated for three-phase applications up to 10 hp
More informationC E R T I F I C A T E O F C O M P L I A N C E
Issued to: ABB FRANCE ACTIVITE PROTECTION ET CONTROL 10 RUE AMPERE 69685 CHASSIEU CEDEX FRANCE This is to certify that representative samples of MOTOR CONTROLLERS, MAGNETIC See Addendum Pages Have been
More informationCIRCUIT BREAKERS. Explosionproof Circuit Breaker Enclosures EXPLOSIONPROOF MOTOR CONTROL EXPLOSIONPRROOF MOTOR CONTROL BREAKERS ENCLOSURES
CIRCUIT BREAKERS Explosionproof Circuit Breaker Enclosures BREAKERS Circuit breakers are thermal magnetic type and are available in frame sizes ranging from 15 to 800 amperes Also available as non-automatic
More informationBulletin 109 IEC Non-Reversing Starters. Product Overview/Product Selection. Table of Contents
Bulletin IEC Non-Reversing Starters Product Overview/Product Selection Cat. No. -CABAF--R-P IP (Type ) Metal Enclosure with Lift-off Cover Bulletin IEC Non-Reversing Starters Impact-resistant molded enclosures
More informationC E R T I F I C A T E O F C O M P L I A N C E
Issued to: SIEMENS AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE 48 92220 AMBERG, GERMANY This is to certify that representative samples of Motor Controllers, Magnetic USL, CNL - Type No 3RT10, 3RT11,
More informationType FEC Epoxy Encapsulated, Copper-Wound Industrial Control Transformers
Type FEC Epoxy Encapsulated, Copper-Wound Transformers ISO 900:2008 REGISTERED 0 Transformer Selector Guide Type FEC Transformers...Page 02 Primary Fusing Option...Page 07 Primary Overcurrent Selection...Page
More informationVS1PFB 230V, 50/60 Hz, 3-Phase
Farm Duty Unit Handling Brake 200 & 575 Volt Pump and Fan Bypass AC Drive 7.5 thru 40 Hp 7.5 thru 125 Hp & Controls 230 VAC 460 VAC 3 Phase - 50/60 Hz 3 Phase - 50/60 Hz Applications: Pump and Fan AC Drive
More informationTypes of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are:
Introduction Motor starters are one of the major inventions for motor control applications. As the name suggests, a starter is an electrical device which controls the electrical power for starting a motor.
More informationLIST PRICES WAC AIR CURTAINS
PRICE SHEET PSWAC-2 EFFECTIVE: March 1, 2011 SUPERSEDES: PSWAC-1 LIST PRICES WAC AIR CURTAINS 4830 TRANSPORT DRIVE, DALLAS, TX 75247 PHONE: 214-638-6010 FAX: 214-905-0806 WAC AIR CURTAINS Basic Unit ITEM
More informationDrying Tumblers 110 Pound Capacity Refer to Page 3 for Model Numbers. Parts
Drying Tumblers 0 Pound Capacity Refer to Page 3 for Model Numbers Parts Part No. M444R April 000 Table of Contents Title Page Parts Ordering Information... Nameplate Location... Model Identification...
More informationPARTS LIST, COUNTER CONVECTION STEAMERS MODELS SN-3E, SN-4E, SN-5E PARTS LIST COUNTER CONVECTION STEAMERS BLODGETT MODELS: SN-3E SN-4E
PARTS LIST COUNTER CONVECTION STEAMERS BLODGETT MODELS: SN-3E SN-4E November 27, 2013 BLODGETT OVEN CO 44 lakeside Ave Burlington, VT 05446 Tel. 802-658-6600 Fax 802-860-3732 www.blodgett.com 1 2013-11-27
More informationSoftstarters Type PSS. Softstarters. General information
General information The PSS Softstarter line brings a wide array of benefits for smaller motors in a flexible, compact form. The PSS "Flexible" Softstarter line PSS18/30 to PSS300/515 softstarters provide
More informationSPECIFICATIONS NB SKILLS TRADE 19 AUTOMATION AND CONTROL
SPECIFICATIONS NB SKILLS TRADE 19 AUTOMATION AND CONTROL NBCC/CCNB 2016 1.1 SCENARIO. 3 1..1 GENERAL.. 3 1..2 STEP A: WIRING AN AUTOMATED PROCESS WITHIN A PANEL 3 1..3 STEP B: PROGRAMMING THE AUTOMATED
More informationA. Products shall be designed, manufactured, tested, and installed in compliance with the following standards:
SECTION 26 29 13 ENCLOSED MOTOR CONTROLLERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical General
More informationMERCURY TO METAL CONTACTORS AND RELAYS
MERCURY TO METAL CONTACTORS AND RELAYS DESCRIPTION MERCURY TO METAL CONTACTOR: The load terminals are isolated from each other by the glass in the hermetic seal. The plunger assembly, which includes the
More informationDirect Gas-Fired Heating
Direct Gas-Fired Heating Model DG 800 to 15,000 cfm Up to 1,600,000 BTU/hr Optional Evaporative Cooling January 2005 PRODUCT FEATURES Model DG Direct Gas-Fired Make-Up Air Unit The Greenheck model DG is
More informationStarters. Across the line. Across the line starters Open & enclosed A9 AF750. Description A9 AF750. Starters. Enclosure types
Across the line starters & enclosed A9 AF750 Across the line Description A9 AF750 Maximum UL horsepower ratings UL508A Panel Program, #E105450 NEMA s (00 7) available Compact space-saving design Standard
More informationMAGNETIC MOTOR STARTERS
Chapter 6 MAGNETIC MOTOR STARTERS 1 The basic use for the magnetic contactor is for switching power in resistance heating elements, lighting, magnetic brakes, or heavy industrial solenoids. Contactors
More informationASL09..S 3-pole Contactors - Spring Terminals
4 kw 5 hp ASL09..S 3-pole Contactors - Spring DC Operated Description - 3-pole contactors with spring terminals, - N.C. or N.O. built-in auxiliary contact, - Low coil consumption, - Polarity on the coil
More informationGPH2 Combination Soft Starters
Combination Soft Starters The Combination Soft Starter is a NEMA 4/12 Enclosed industrial general purpose AC motor soft starter package. It is designed for simple and quick installation and start-up, requiring
More informationNEMA Contactors & Starters (Freedom)
Page 1 February, 1 Supersedes TIP AN1, AN, CN1, CN Pages 1-0, Dated 1/1/4 ECN01, ECN0, ECN0, ECN0, ECN0 AN1, AN, CN1 & CN Sizes 00-, 00V Max. Non-Reversing & Reversing NEMA Type Enclosures 1, R, 4X & 1
More informationMK IV HORIZONTAL SLIDING DOOR REPLACEMENT PARTS BOOK
MK IV HORIZONTAL SLIDING DOOR REPLACEMENT PARTS BOOK BI-PARTING DOOR SHOWN-SINGLE DOOR SIMILAR JAMISON DOOR COMPANY P.O. BOX 70 HAGERSTOWN, MARYLAND 21740 1-800-532-3667 301-733-3100 INTERNET: http://www.jamisondoor.com
More informationIEC Utilization Categories (Explanation)
IEC Utilization Categories (Explanation) IEC Utilization Categories Voltage Category Typical Applications A.C. A.C. and D.C. D.C. AC AC AC AC ACa ACb AC6a AC6b AC7a AC7b AC8a AC8b AC AC AC AC AC AC AC
More informationGrout Pump Automatic & Manual Troubleshooting Gas Wiring Diagram
Grout Pump Automatic & Manual Troubleshooting 40-500 Gas Wiring Diagram Turn engine off and relieve hydraulic pressure and grout pressure before troubleshooting. Note: Typically there is a wiring diagram
More informationUPS packages are charged dimensional, not physical weight.
Electric Heater Packing List NOTE: All items shown in this booklet are part of our EL and TBAC price code categories. Heaters & Accessories Effective 7-1-13 All orders are subject to acceptance by Detroit
More informationOpen & enclosed. Spec Tech Industrial 203 Vest Ave. Valley Park, MO Phone: 888 SPECTECH. Reduced voltage starters. Overload relay protection
Reduced voltage starters Open & enclosed Reduced voltage starters Description Compact, space saving design 8 starter frame sizes, A16 to A750 Maximum U.L. horsepower ratings Mechanically interlocking as
More informationUser s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual
User s Manual ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual ii ACH550-CC/CD Packaged Drive with Classic Bypass ACH550 Drive Manuals GENERAL MANUALS ACH550-UH
More informationAIR CURTAINS AIR CHAMBER DESIGN
AIR CURTAINS AIR CHAMBER DESIGN Pittsburgh, PA Akron, OH Atlanta, GA Los Angeles, CA INDEX How an Air Curtain Works...3 Making an Air Curtain...3 Choosing The Right Air Curtain...4-5 Energy Saving & Return
More informationASCO SERIES 185 Power Transfer Switches
ASCO SERIES 185 Power Transfer Switches ASCO SERIES 185 Power Transfer Switches An Automatic Transfer Switch helps prevent... - - - ASCO is there for you even when you re not - SERIES - SERIES SERIES -
More informationContacts NEMA A600, 10A thermal. Contacts NEMA Q600, 5A thermal. Low energy contacts gold plated. Minimum PUSHBUTTON
Pilot Devices Technical data UL General UL technical data Contact blocks Rated insulation voltage, UL 600V Rated thermal current 10A / 600VAC 2.5A / 600VDC Minimum rating 24VDC, 5mA Mechanical life (millions
More informationNon-illuminated Push Buttons
Non-illuminated Push Buttons 3 Accessories for push buttons Lockout attachment Contact block kits Lens kits Wobblestick kit Push Button Cap Interchangeable, snap-in design Protective caps 9 colors: red,
More informationContactors & Starters Index
ontactors & Starters Index NEMA ontrol Description Page Number General Information - HP... A Magnetic ontactors - HP...4 A Magnetic Reversing ontactors - HP... 4 A Magnetic Starters - HP... A Magnetic
More informationHVAC Drives Lenze AC Tech MCH Series Price Book May US Dollars
HVAC Drives Lenze AC Tech MCH Series Price Book May 2015 - US Dollars Document: pcmchusd-0515_a MCH Series Drives: Model Number Designation Code The MCH Series drives are rated for variable torque applications,
More informationCommercial Garage Door & Gate Operators
Commercial Garage Door & Gate Operators Approved to UL Standard 325 Industrial Electronic Door Control LYNX 6000 2 1. Electronic Control Provides unmatched ruggedness that incorporates the newest features
More informationTANK LIDS, REAR STEP AND WHEELS
TANK LIDS, REAR STEP AND WHEELS M9060-22 Rev.4/98 FOR MODELS - KP4F, KP6F, KP6R 4/98 Item Part Number Part Description Qty. 1 9040--16--0 Tank Lid Weldment (KP4F -- Front Load) 1 9060--16--0 Tank Lid Weldment
More informationOverload Relays. SIRIUS 3RU2 Thermal Overload Relays 3RU2 up to 40 A for standard applications. 5/78 Siemens IC Overview
SIRIUS 3RU2 Thermal Overload Relays 3RU2 up to 40 A Overview 1 2 3 4 6 1 2 NSB0_0207a Connection for mounting onto contactors: Optimally adapted in electrical, mechanical and design terms to the contactors.
More informationProtectors. 35mm DIN rail snap-on mounting. Wide range of accessories
Manual motor protectors Manual motor protectors Manual motor Protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certified
More informationSECTION MOTORS & MOTOR CONTROLLERS
SECTION 15170 MOTORS & MOTOR CONTROLLERS PART 1 GENERAL 1.01 SECTION INCLUDES A. Electric motors. B. Motor controllers for Packaged equipment. 1.02 SUBMITTALS A. Wiring diagrams with electrical characteristics
More informationAF09... AF30 3-pole Contactors up to 20 HP / 480 VAC
AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory
More informationCommercial Radiant HeaterRH Series
RH A 33 C 1 D E 25W F A: Series : Length C: Housing Color -lack, S-Stainless D: Lamp Quantity E: Volts A=120, =208 C=240, D=480, E=575 F: Wattage lack powder-coat aluminized steel housing Optional stainless
More informationMicro Contactor MA Series
Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC
More information3. Coils shall be of molded construction
.7-4 Motor Starters & Contactors Low Voltage Enclosures General Non-Combination Starters January 00 Sheet 8 0 7 8 9 4 Non-Combination Starters Maximum hp, Volts Typical Non-Combination Starter Application
More informationCOVER PLATES & ROLLERS
COVER PLATES & ROLLERS 9035-10 Revised 8/95 FOR MODELS - ALL 3/98 Item Part Number Part Description Qty. 1 9035--1--10 Top Cover Plate 1 2 62--425 3/8NC x 3/4 Hex Washer Thread Cutting Screw 8 3 62--544
More informationMODEL 10LH SPECIFICATION
MODEL 10LH SPECIFICATION 1.0 General Specifications There will be furnished one (1) only Grind Hog TM Model 10LH Comminutor as manufactured by G.E.T. Industries, Inc. Rotation shall be in a clockwise (standard)
More informationAF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101404D0201 24/03/11-30-10-.. / Z-30-10-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220
More informationIndustrial Control Transformers
6 Industrial Control Transformers Section 6 Industrial Control Transformers provide a low and safe control voltage for the operation of electromagnetic devices, such as motor starters, contactors, solenoids
More information800 T FX 1 A1. Color Cap. No cap 1 Green 2 Black 3 Orange 4 Grey 5 White 6 Red 7 Blue 9 Yellow. Contact Block(s) Operator Position.
2-Position Push-Pull and Push-Pull/Twist Release Devices, Non-Illuminated Note: A jumbo or large legend plate is recommended, if space allows. 2-Position Push-Pull Cat. No. 800T-F6D4 2-Position Metal Push-Pull
More informationCOMPACTOR & RAM ASSEMBLY
P1 P2 COMPACTOR & RAM ASSEMBLY FOR MODELS - ALL 5/02 Item Part Number Part Description Qty. 1 64--129 1--1/2 STD. Flat Washer 10 2 9121--1--8 Cylinder Pin, Base 1 3 60--608 1/4 DIA. x 2--1/2 Roll Pin --
More informationProduct guide. Enclosed NEMA starters. usa.siemens.com/controls
Product guide Enclosed NEMA starters usa.siemens.com/controls The right choice for applications that demand the best Siemens NEMA combination and non-combination starters for industrial and construction
More informationAC Relays. Type IC5182. Ordering Information. Control Power Requirements. Contact Ratings (Amperes)
AC Relays Type IC5182 Series N147 Overload Relays are of the magnetically operated self reset type, designed for use on A.C. or D.C. motor starters and controllers for Navy Service A applications. Specification
More informationConsider The Possibilities...
FS/FD Air-Cooled Fluid Cooler Catalog 710.1 Consider The Possibilities... Cools most any non-corrosive fluid Closed-circuit cooling avoids contamination Cold weather economizer for interior cooling loads
More informationWARREN COUNTY, N.Y. M/E REFERENCE
SECTION 262000 - ELECTRIC DISTRIBUTION PART 1 - GENERAL 1.1 DESCRIPTION A. Provide a complete secondary distribution system as indicated on the Contract Documents and as specified herein. 1.2 QUALITY ASSURANCE
More informationSECTION AIR TERMINAL UNITS
SECTION 23 36 00 AIR TERMINAL UNITS PART 1 - GENERAL 1.1 SUMMARY A. Section includes constant volume terminal units, variable volume terminal units, dual duct terminal units, fan powered terminal units,
More informationB BASIC HEAT TREATMENT CONSOLE
Maritime Stress PO Box 2898, 30 Estates Road Dartmouth, NS, B2W 4Y2, Canada Toll Free: 1-877-468-1781 Phone: (902) 468-7873 Fax: (902) 468-2304 Website: E-mail: info@maritimestress.com OPERATION MANUAL
More informationEnclosures. See Section Typical Description
January 00 Sheet 1187 Motor Starters & Contactors Low Voltage Enclosures General Individual Enclosed, ac Full Voltage.7- Combination Starters Maximum 00 hp, Volts Application Size 1, NEMA 1, Enclosed Magnetic
More informationProgrammable Logic Controller. Mat Nor Mohamad
Programmable Logic Controller Mat Nor Mohamad Relays Electromagnetic Control Relays The PLC's original purpose was the replacement of electromagnetic relays with a solid-state switching system that could
More informationFile E31519 Project 10CA February 4, 2011 REPORT MAGNETIC MOTOR CONTROLLERS. Siemens AG Amberg, Germany
File E31519 Project 10CA65262 February 4, 2011 REPORT on MAGNETIC MOTOR CONTROLLERS Siemens AG Amberg, Germany Copyright 2011 Underwriters Laboratories Inc. Underwriters Laboratories Inc. authorizes the
More informationEPS-ECONOMY PUMP STARTER
EPS-ECONOMY PUMP STARTER NEMA 1 & 3R ENCLOSURES franklinwater.com EPS-ECONOMY PUMP STARTER - 1 & 3 PHASE, 50/60HZ, 200-600 VAC, 1-80A The enhanced Franklin Electric Economy Pump Starter (EPS) provides
More informationBT300 HVAC Drives Conventional Bypass (C-Bypass) Options
BT300 HVAC Drives Conventional Bypass (C-Bypass) Options Description The BT300 Conventional Bypass is a companion package for the family of BT300 HVAC Drives. For information on the family of BT300 HVAC
More informationMECHANICAL AND ELECTRICAL COORDINATION SECTION MECHANICAL AND ELECTRICAL COORDINATION PART 1 - GENERAL
13686.00 MECHANICAL AND ELECTRICAL COORDINATION 230002-1 SECTION 230002 MECHANICAL AND ELECTRICAL COORDINATION 1.1 WORK INCLUDED PART 1 - GENERAL A. Work Included in This Section: Materials, equipment,
More informationIEC CONTACTORS. Contacts Model List Model List AC3 UL 115 V 230 V 200 V 230 V 460 V 575 V NO NC Number Price Number Price 3RT101
IEC CONTACTORS Description: RT01 Contactors Are Available With Cage Clamps On The Main Terminal Connections As Well As The Auxiliary Terminal Connections. RT02, RT0 and RT04 Contactors Are Available With
More informationProduct guide. Enclosed NEMA starters. Answers for industry.
Product guide Enclosed NEMA starters Answers for industry. The right choice for applications that demand the best Siemens NEMA combination and non-combination starters for industrial and construction applications
More informationKnob Lever Operator Cat. No. 800T-H17A 800 T HA 2 A. Protection Rating Description T Metal, Type 4/13 Plastic, Type 4/4X/13
2-Position Selector Switch Devices, Non-Illuminated Standard Knob perator Cat. No. 800T-H2 Knob Lever perator Cat. No. 800T-H17 Standard Knob perator Cat. No. 800H-HR2 800 T H 2 a b c d e a Protection
More informationEnclosed Full-Voltage Starters
GE Energy Connections Made in USA Enclosed Full-Voltage Starters * www.geindustrial.com/products/starters GE Global Offer & Warranty starters utilize globally-rated IEC components which make it ideal for
More informationFan Coil Unit (FCU) Fan Motor Control
Fan Coil Unit (FCU) Fan Motor Control Fan Relay Board 2 (FRBii) Installation, Operation, and Maintenance The Fan Relay Board assembly (FRBii) provides electronic control for the fan motor and various connections
More informationAF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts
AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up
More informationGe 600 Manual Transfer Switch 200 Amp Nema 3r
Ge 600 Manual Transfer Switch 200 Amp Nema 3r Generac offers more options for transfer switches than any other manufacturer. Generac offers a full line of Industrial Transfer Switches to meet varying 100-800,
More informationEnclosed Full-Voltage Starters
GE Energy Connections Made in Canada Enclosed Full-Voltage Starters * ca.geindustrial.com/products/starters GE Global Offer & Warranty starters utilize globally-rated IEC components which make it ideal
More informationMS303DS MS-303 3P Man CNT Only. Features. Dimensions and Weight. Long Description
MS303DS MS-303 3P Man CNT Only Leviton Manufacturing Catalog Number Manufacturer Description Weight per unit Product Category Features action TPST actuator Toggle amperage rating 30 connection Back Wired;Side
More information1/4HP - 7.5HP 120/240/277 VOLTS 50/60HZ
Installation & Operating Procedures DG2 Series SINGLE PHASE CONVERTERS 1/4HP - 7.5HP 120/240/277 VOLTS 50/60HZ TABLE OF CONTENTS 1.0 DESCRIPTION... Pg. 1 2.0 INSTALLATION AND START-UP... Pg. 3 3.0 DRAWING
More informationXT SERIES Jockey Pump Controllers Features
XT SERIES Jockey Pump Controllers Features XT Series Jockey Pump Controllers March 2012 1-1 XT Power Controls The XT Series of Jockey Pump Controllers incorporate Eaton s XT Power Controls which are designed
More information