CS / CSJ / CSS / CSK / CSP

Size: px
Start display at page:

Download "CS / CSJ / CSS / CSK / CSP"

Transcription

1 Contact type position switch series 1-signal plunger type (Cylindrical type M) CS67A (Cylindrical type M6 (Cylindrical type M8) CSK87A(Long stroke) CSP87A-A (Water-resistant) Slim design allows side by side installation, wide range of variations. From M / long stroke / water-resistant High performance at reasonable price. micron in repetitive accuracy Application Slipping after push-in Representative specification Treaded/ Non-threaded Long stroke Water-resistant Output mode Stroke Size Contacting part M. 2 plunger, 2 CSS6 AB CS67 AB B : NC plunger, M plunger, CSK87 AB CSP87 AB-A B : NC 2.8 S2 -A : Contacting part, Protective structure with LED -L CSJSA-L CS6 A -L CSS6 AB -L CS67 A B -L -L -L CSK87 AB -L IP67 CSP87 AB -AL -L : LED indicator (12mm from the switch) Common specification structure Output mode Pretravel Repeatability Movement differential Contact life time Contact force Case material Dry contact A : Normally open / B : Normally close.3 Both OnOff, OffOn/. (At operating speed 2mm/min) * 1million (If no specified bungle caused by vibration and used under voltage and current rating) 1N SUS HRc * Operating speed slower than 1mm/min is not recommended. (Refer to P2-9) Operating temperature range Temperature drift Oscillation Impact Contact rating Standard accessory The following options are available. Transistor output (Refer to P2-4) Reverse connect protection. Level conversion. Output current is increased to 1mA. Shape of contacting part Standard length 3m Oil resistant2.8 / 2 cores, Tensile strength 3N, minimum bending R7 protector (Detachable) for CSJ C8 C (Ice-free) 1Hz total amplitude 1. for X,Y,Z each direction 3m/s 2 for X,Y,Z each direction DCVDC24V Steady current: 1 ma or less (rush current: 2 ma or less) Two fixing nuts for threaded type Protective cover LED indicator Contact force direction Heat resistance (P6-4) 4-3

2 Cylindrical type M / ANO ANO 4.4 M. protector protector (Width : S (Width Cylindrical type M6 / 6 ANO 4.3 CSS6A ANO CSS6B BNC (42) (Width : S (42) CS67A ANO CS67B BNC Cylindrical typem8 / 8 ANO (42) (Width : S63B ANO 3. 6 Long stroke type CSK87A ANO CSK87B BNC Stroke mm (43.) 7 (Width (Width (43.) : S628B Water resistant type (IP67) CSP87A-A ANO CSP87B-A BNC (4.) (-L: LED indicator) 7 (Width S (Width 12 (2)

3 direction 9 (Option) -R (Cylindrical type M) CS67A-R (Cylindrical type M6 -R (Cylindrical type M8) Slim design allows side by side installation, wide range of variations. From M / long stroke / water-resistant High performance at reasonable price. micron in repetitive accuracy without an amplifier CSK87A-R (Long stroke) Representative specification ( direction 9) Treaded/ Non-threaded Long stroke -R -R -R CSS6 AB -R CS67 AB -R -R -R CSK87 AB -R Output mode B : NC B : NC Stroke Size M. 6 8 M8.7 Contacting part 2 plunger, 2 plunger, 3. plunger, Protective structure with LED -LR CSJSA-LR CS6 A -LR CSS6 AB -LR CS67 A B -LR -LR -LR CSK87 AB -LR -R: direction 9 -L: LED indicator (12mm from the switch) Caution: If the shape of contact is larger than the screw or case diameter, it cannot be inserted through the installation hole. In such case, please use either a split bush or by a bracket U-cut, etc. Common specification structure Output mode Pretravel Repeatability Movement differential Contact life time Contact force Case material Dry contact A : Normally open / B : Normally close.3 Both OnOff, OffOn/. (At operating speed 2mm/min)* 1million (If no specified bungle caused by vibration and used under voltage and current rating) 1N SUS HRc *Operating speed slower than 1mm/min is not recommended. (Refer to P2-4) Operating temperature range Temperature drift Oscillation Impact Contact rating Standard accessory The following options are available. Transistor output (Refer to P2-4) Reverse connect protection. Level conversion. Output current is increased to 1mA. direction Standard length 3m Oil resistant2.8 / 2 cores, Tensile strength 3N, minimum bending R7 protector (Detachable) C8 C (Ice-free) 1Hz total amplitude 1. for X,Y,Z each direction 3m/s 2 for X,Y,Z each direction DCVDC24V Steady current: 1 ma or less (rush current: 2 ma or less) Two fixing nuts for threaded type Protective cover LED indicator Contact force Shape of contacting part Heat resistance (P6-4) 4-

4 M / Treaded / Non-threaded direction: -R (9 ) - RA: NO (44.4) RA: NO (44.4) RA: NO (4) M : S : S629 M6 / 6 Treaded / Non-threaded direction: -R (9 ) CSS6A - RA: NO (4) CSS6B - RB: NC (37) CS67A - RA: NO (4) CS67B - RB: NC (37) M8 / 8 Treaded / Non-threaded direction: -R (9 ) - RA: NO (49.) RA: NO (49.) : S63B Long stroke type direction: -R (9 ) CSK87A - RA: NO CSK87B - RB: NC Stroke mm (66.2) LED indicator -LR: Specify the position >12mm LED indicator -LDR 11 : S628B 12 (2)

5 9 Options Shape of contacting part Protective cover LED indicator Contact force direction 2 CSS6 AB CS67 AB 3. CSK87 AB Blank: 2 plunger A: 2 flat B: 4 flat C Needle DP: Plastic Blank: 3. B: 3. flat T: Replaceable T: Fixed contacting part TA: Adjustable contacting part Blank: No protective Blank: No LED L: 12mm from the switch LD *: Attached to the switch *Available only when perpendicular cable direction R is selected. Blank: 1N S:.3N G:.N H:1.N (The rubber scraper is not provided for S. IP4) (Normally close type not acceptable for S and G) Blank: 1N S:.3N G:.N H:1.N (The rubber scraper is not provided for S,G. IP4) (Normally close type not acceptable for S and G) Blank: Straight R: 9 Blank: Standard (3m) Option: (Not selectable when transistor output is selected) Connector CN-2H (Refer to P4-9) Water resistant type CSP87 AB Transistor output TNA TNB TPA TPB Added to standard product name A: S2 ball SUS, B: 3 flat T: Fixed contacting part TA: Adjustable contacting part Only for CSP D Blank: No protective D: Downward U: Upward 1 Blank: No LED L: 12mm from the switch U Blank: 1N Blank: Straight R: 9 (Not available for CSP ) 11 (Refer to P2-4) 7 1 e.g.) -ALSR Transistor output e.g.)tna-bdl- 2 CSS6 AB CS67 AB A A 2 3. B CSK87 AB 3. Rubber 8 7.8CSJ 6 Water resistant type(ip67) CSP87 AB B B (CSK) CSJ 2.8 C: Needle 1. M2.D (Counter bore1) (CSK) CSJ 6 4. T: Replaceable(ThreadedM2.) DP (Material: Plastic) T: Replaceable (ThreadedM2.) TA~TE Compatible with contacting parts of commercially produced dial gauges LDR: If the shape of contact is larger than the screw or case diameter, it cannot be inserted through the installation hole. In such case, please use either a split bush or by a bracket U-cut, etc. L: Tubular type 12 (2) Transistor output type (27) 4. Integrated with sensor (Not available for CSP) direction S (A) 2.(B) M2.D (Counter bore1) 22.3 TA~TE Compatible with contacting parts of commercially produced dial gauges *Available only when perpendicular cable direction R is selected. 4-7

6 Options Shape of contactiong part Contact type position switch series Explanatory notes for options Shape of contactiong part 2 plunger type Mark: Shape Blank: 2 plunger Shape of detected objects Water-resistant Mark: Shape A: S2 ball carbide Shape of detected objects A: 2 flat Convex, (IP67) B: 3 flat Convex, ball (Cutters, drills) B: 4 flat ball (Cutters, drills) CSP87 AB T: Replaceable Specify mounting direction CSS6 AB CS67 AB 3. plunger type C: Needle DP: 3., Blank: 3. plunger B: 3. flat Small detected surface Convex, ball (Cutters, drills) Threaded M2. Contact force (Not available for CSP) when using special shape or heavy contacting parts. CSK87 AB T: Replaceable Threaded M2. Specify mounting direction when using special shape or heavy contacting parts. Mark: Shape S:.3N G:.N Operationg condition No chattering caused by vibration or impact (No rubber boot is provided for S, IP4) H: 1.N Intense vibration or impact Refer to P6-2 for low contact force type (.1/.2N) Fixed contacting parts S2 ball M2. Mark : TAF413S TAWF413W S3 ball S3 M2. Mark : TEF41S TEWF41W flat M2. TBW F4131W flat 2. TDW F4132W Needle S M2. TCF4129S TCW F4129W Example when ordering: -T A -T B W MarkShape of contacting part Adjustable contacting parts This can make installation process easier and eliminate the risk of twisting the cable when adjusting the signal point of the switch. S2 ball S M2. Mark : TAAF413AS TAAWF413AW S3 ball S M2. Mark : TEA F41AS TEAWF41AW 3 flat M2. TBAWF4131AW flat TDAW F4132AW Needle S1 14. M TCAF4129AS TCAWF4129AW Accessory for the adjustable contacting parts : Locknut for adjustment and spanner Example when ordering: -T A A -T B AW MarkShape of contacting part 4-8

7 Connector (Only applicable for cabtyre cables, not usable when transistor output is selected.) Mark Product name Protective Structure Dimension Pullout strength Only applicable for cabtyre cables, not usable when transistor output is selected. CH CN-2H 2cores side Machine side 6 1.N The switch side is able to go through M6 nuts. e.g.-1-ch-2 ( / side cable1m / Connector CN-2H / Machine side cable 2m Protective covers Choose the suitable cover according to switch mounting direction so that the metal cuttings and coolant can t enter from the gaps. (Refer to P7-7) D: Mostly for downward installation Protective cover Gap U: Mostly for upward installation Protective cover Gap Note when installing on brackets, etc. : When the diameter is large or a U shaped protection boot or special contact is used, pass the switch from the front side of the installation hole (remove the relay connector before installation). Tightening torque for case screws and nuts CS-Touch Circuit diagram No LED Screw / Nut Tightening torque Applicable models Mx. M6x. M6x.7 M8x.7 2Nm 4Nm 4Nm 7Nm CSJ CS6 CS67 CSP87 Normally open Brown(Red) Normally close Blue (White) Brown(Red) Blue (White) with LED Normally open LED Normally Off Normally close Brown(Red)+ Blue (White)- Brown(Red)+ Blue (White)- LED Normally On Electrical specification / circuit diagram. (Refer to P2-1) When using the switches with LED option, limit the current below 1mA. (Refer to P7-3) For metal cuttings and coolant Protective cover is strongly recommended to avoid damage from cuttings and coolant when the switch is used in machining environment. In addition, an extra cover is recommended to avoid direct hit by high-pressure coolant or heavy cuttings. For horizontal mounting, an extra cover prevents coolant or cuttings from entering inside and getting piled up on the body. Fabricate and place an extra cover to avoid metal chips adhering to the rubber boots during the grinding operation. Metal cutting Protect structure CSP type (IP67) A rubber boot is applied to the plunger. Protective cover is available at the user s option to protect the rubber boot from cuttings. Product other than CSP Rubber scraper is applied to the plunger. When the lip of the scraper is damaged by cuttings, the water resistance becomes impaired. How to use Make contact with detected objects at right angle (within deflection angle ±3 ) Do not press the plunger to the stroke end. It may cause malfunction due to the impact. If there is a possibility to press the plunger to the stroke end, install a stopper separately to prevent the malfunction. Detected object shorter than stroke Detected object Rubber boot Rubber scraper shorter than stroke Stopper surface Slipping after push-in Stopper surface 4-9

unit:mm L: LED indicator (120mm from the switch) Add "-L" after cartridge name for LED type

unit:mm L: LED indicator (120mm from the switch) Add -L after cartridge name for LED type CS-Touch CSH Contact type position switch series www.metrol.co.jp/en 1-signal plunger type (Ball bearing) Sliding, angled, offset touch type Direct-sliding ball bearing is equipped to the plunger Suitable

More information

P11GDB-DU. unit:mm. P11GDB-DU LD P11GMB-DU LD P21EDB-DU LD -LD : LED indicator (Attached to the switch) Cable (Refer to P2-4)

P11GDB-DU. unit:mm. P11GDB-DU LD P11GMB-DU LD P21EDB-DU LD -LD : LED indicator (Attached to the switch) Cable (Refer to P2-4) High-accuracy MT-Touch P11 P21 Contact type position switch series www.metrol.co.jp/en 1-signal / 2-signal plunger type Straight touch, Flat type (Plain bearing) PAT.PEND. P11DDB-DU P11EDB-DU P11GDB-DU

More information

IP44 STM61A IP67 STM13A IP44 STM63A IP67 STM31A IP44 STM81A IP67 STM33A IP44 STM83A IP67 STMB11A IP44 STM35A STM12A IP44 STM62A IP67 STM14A

IP44 STM61A IP67 STM13A IP44 STM63A IP67 STM31A IP44 STM81A IP67 STM33A IP44 STM83A IP67 STMB11A IP44 STM35A STM12A IP44 STM62A IP67 STM14A Stopper Bolt with a Built-in STM Machine Components with a Built-in series www.metrol.co.jp/en Seating check plunger type Mini type US.PAT. STM11A STM61A STM13A STM31A STM81A 88 (the smallest) Mini-stopper

More information

STS STE STP. 5-4 No.AB7-2E. Stopper Bolt with a Built-in Switch. 2 tasks with 1 device. Housing a high-accuracy built-in switch in a stopper bolt

STS STE STP. 5-4 No.AB7-2E. Stopper Bolt with a Built-in Switch. 2 tasks with 1 device. Housing a high-accuracy built-in switch in a stopper bolt Stopper Bolt with a Built-in STS STE STP PAT.PEND. Machine Components with a Built-in serieis www.metrol.co.jp/en Seating check, plunger type Straight touch type 2 tasks with 1 device. Housing a high-accuracy

More information

2-1. Tool Setter Series for CNC Machining Centers. toolsensor.com. Summary. Features

2-1. Tool Setter Series for CNC Machining Centers. toolsensor.com. Summary. Features Tool Setter Series for C Machining Centers Summary Metrol tool setters with built-in precision switches are used in C machine tools including C machining centers and C lathes. In addition to presetting

More information

Pneumatic Drive Type Drill Bit Breakage Detection Sensor. DFM3 Series. The World's First!! Pneumatic-Drive Type. Catalog / Instruction Manual US.PAT.

Pneumatic Drive Type Drill Bit Breakage Detection Sensor. DFM3 Series. The World's First!! Pneumatic-Drive Type. Catalog / Instruction Manual US.PAT. Pneumatic Drive Type Drill Bit Breakage Detection Sensor DFM3 Series The World's First!! Pneumatic-Drive Type Catalog / Instruction Manual US.PAT. Pneumatic Drive Type Drill Bit Breakage Detection Sensors

More information

GH-5S. 5.6 times approx. Tightening torque 0.78N m or less. Disconnection Alarm Indicator

GH-5S. 5.6 times approx. Tightening torque 0.78N m or less. Disconnection Alarm Indicator GA- SERIES Amplifier-separated Micro-size Inductive Proximity Sensor GH SERIES -N -U Slim & Small The amplifier is extremely slim, just mm thick. This results in a compact size even if several amplifiers

More information

Terminology - Definitions and Explanations - P7-6. Switch series and parallel connection methods P7-2

Terminology - Definitions and Explanations - P7-6. Switch series and parallel connection methods P7-2 TECHNICAL GUIDE Electrical specifications Terminology - Definitions and Explanations - P7-2 series and parallel connection methods P7-2 Direct current 2-Line Type Direct current 3-Line Type Conditions

More information

FRONT SUSPENSION LOCATION INDEX

FRONT SUSPENSION LOCATION INDEX 1. Remove the front suspension tower bar. (See FRONT SUSPENSION TOWER BAR REMOVAL/INSTALLATION.) 2007 Mazda MX-5 Miata Sport 2007 SUSPENSION Front Suspension - MX-5 Miata FRONT SUSPENSION LOCATION INDEX

More information

International, LLC. HMS/HLS/HNS Series Heavy Duty Limit Switches. Specifications. Features. Electrical Ratings HNS HLS HMS. Non-plug-in.

International, LLC. HMS/HLS/HNS Series Heavy Duty Limit Switches. Specifications. Features. Electrical Ratings HNS HLS HMS. Non-plug-in. HMS/HLS/HNS Series Heavy Duty Limit Switches Features Heavy duty zinc die cast body Conform to EN 6097-5-1, IEC 6097-5-1, UL508, NEMA250, CSA22.2 Standards Wide range of actuator available High repeatability

More information

TECHNICAL GUIDE FOR PROXIMITY SENSORS DEFINITIONS YAMATAKE PROXIMITY SENSOR CATEGORIES

TECHNICAL GUIDE FOR PROXIMITY SENSORS DEFINITIONS YAMATAKE PROXIMITY SENSOR CATEGORIES TECHNICAL GUIDE FOR PROXIMITY SENSORS DEFINITIONS "" includes all sensors that detect the presence of a metallic object approaching the sensing face or near the sensing face without mechanical contact.

More information

DC2-Wire Spatter-Guarded Cylindrical Proximity Switches

DC2-Wire Spatter-Guarded Cylindrical Proximity Switches DC-Wire Spatter-Guarded Cylindrical Proximity Switches FL7M Series A variety of anti-spatter measures make these switches the optimum for welding processes on the automotive production line. With Teflon

More information

Model Number Structure

Model Number Structure Small Sealed Switch D4E-@N Slim and Compact Switch with Better Seal and Ensuring Longer Service Life than D4E Flat springs with an improved lever ratio of the built-in switch ensure smooth snap action

More information

FL7M-A Series. Aluminum-chip Immunity DC 2-wire Type Cylindrical Proximity Sensors. Specifications. click FEATURES ORDER GUIDE

FL7M-A Series. Aluminum-chip Immunity DC 2-wire Type Cylindrical Proximity Sensors. Specifications. click FEATURES ORDER GUIDE 6 FL7M-A Series FEATURES Workpieces Reliably Sensed Even if Aluminum or Cast Iron Chips Accumulate on the Sensing Head. This DC 2-wire type proximity sensor can be directly connected to programmable controllers

More information

GX-5SU(B) is just 5.4 mm 0.213in in diameter, the smallest in existing DC two-wire sensors. It saves you space.

GX-5SU(B) is just 5.4 mm 0.213in in diameter, the smallest in existing DC two-wire sensors. It saves you space. DC 2-wire Cylindrical Inductive Proximity SERIES High performance & ease of use Amplifier Built-in Robust in tightening The tightening torque has been improved to approx. four times greater than that of

More information

DC2-Wire Aluminum-Chip Resistant Cylindrical Proximity Sensors N.O. N.C. N.O. N.C. N.O. N.C. 8mm N.O. N.C. N.O. N.O. N.C. N.O. N.O. N.C.

DC2-Wire Aluminum-Chip Resistant Cylindrical Proximity Sensors N.O. N.C. N.O. N.C. N.O. N.C. 8mm N.O. N.C. N.O. N.O. N.C. N.O. N.O. N.C. DC-Wire Aluminum-Chip Resistant Cylindrical Proximity Sensors FL7M-ASeries Detects workpieces reliably even if aluminum or cast iron chips accumulate on the sensing head. DC-wire proximity sensors can

More information

DC2-Wire Unshielded Cylindrical Proximity Switches

DC2-Wire Unshielded Cylindrical Proximity Switches DC2-Wire Unshielded Cylindrical Proximity Switches FL7M Series Unshielded switches achieve especially long sensing distances Long sensing distance (2 times the sensing distance of a regular FL7M) DC2-wire

More information

Sensing distance. 4mm. 4mm. 7mm. 12mm. 20mm

Sensing distance. 4mm. 4mm. 7mm. 12mm. 20mm DC2-wire Square Proximity Sensors FL2R/SSeries This DC2-wire Square Proximity sensor Can Be Directly Connected to Programmable Controllers and Units. Wide Range of Models Available. Reduced wiring costs

More information

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from Omron STI Application Support Thank you for your interest in Omron STI products. Please contact Omron STI with your application questions. Support Engineers are available at our USA headquarters from 4:00

More information

SG-B1 SERIES / SG-A1 SERIES

SG-B1 SERIES / SG-A1 SERIES 643 Door with Solenoid Interlock / Door Ultra-slim SG-B1 SERIES / SG-A1 SERIES Related Information General terms and conditions... F-7 General precautions... P.1501 PHOTO PHOTO Conforming to Machine &

More information

Safety Limit Switch

Safety Limit Switch Safety Limit Switch D4B-@N CSM_D4B-_N_DS_E_5_1 Snap-action contact with certified direct operation certification. Maintenance, seal, and resistance to shock increased and direct mechanism added. Three-conduit

More information

Contactless Touch Switches

Contactless Touch Switches es 4 Patents applied for Features Long lasting, stable operation even under frequent use because of lack of physical contact. Capable of very high precision in repeatability of operating point. The configuration

More information

DC 2-Wire Unshielded Cylindrical Proximity Sensors. Operation mode. Setting indicator N.O. N.C. N.O. N.C. N.O. N.C. N.O. N.C. 20mm N.O. N.O. N.O.

DC 2-Wire Unshielded Cylindrical Proximity Sensors. Operation mode. Setting indicator N.O. N.C. N.O. N.C. N.O. N.C. N.O. N.C. 20mm N.O. N.O. N.O. DC 2-Wire Unshielded Cylindrical Proximity Sensors FL7MSeries Unshielded sensors achieve especially long sensing distances Long sensing distance (2 times the sensing distance of a regular FL7M) DC 2-wire

More information

INSTRUCTION MANUAL. 1. Introduction 2. Safety Instructions.. 2 Unpacking Description. 2. Main Features... 3 Technical Data...

INSTRUCTION MANUAL. 1. Introduction 2. Safety Instructions.. 2 Unpacking Description. 2. Main Features... 3 Technical Data... F111.H.BD Bi-Directional Turbine Flow Sensor for Hot Tap Installation INSTRUCTION MANUAL EN 10-11 Table of Contents 1. Introduction 2 Safety Instructions.. 2 Unpacking.. 2 2. Description. 2 Main Features...

More information

MGX. 2-jaw parallel self-centering pneumatic gripper series MGX. Parallel grippers. Pinze parallele MGX

MGX. 2-jaw parallel self-centering pneumatic gripper series MGX. Parallel grippers. Pinze parallele MGX Pinze parallele MGX Parallel grippers MGX 2-jaw parallel self-centering pneumatic gripper series MGX Flat profile. Robust guide. High gripping force. Small weight and dimensions. High dimensional accuracy.

More information

TL-W. Standard Flat Sensors in Many Different Variations. Flat Inductive Proximity Sensor. Ordering Information

TL-W. Standard Flat Sensors in Many Different Variations. Flat Inductive Proximity Sensor. Ordering Information Flat Inductive Standard Flat s in Many Different Variations Only 6 mm thick yet provides a sensing distance of mm (MC1). Aluminum die-cast models also available. Be sure to read Safety Precautions on page

More information

OMRON Z LIMIT SWITCH

OMRON Z LIMIT SWITCH Issued April 00 DATA SHEET OMRON LIMIT SWITCH Based on OMRON Datasheet General-purpose Basic Switch CSM DS_E Best-selling Basic Switch Boasting High Precision and Wide Variety A large switching capacity

More information

If it exceeds the maximum specification, replace the propeller shaft.

If it exceeds the maximum specification, replace the propeller shaft. If it exceeds the maximum specification, replace the propeller shaft. Maximum runout o 0.4 mm {0.016 in} 2. Inspect the play and rotation of the joint by turning the universal joint in the directions shown

More information

Ordering Information. General-purpose Basic Switch X. Direct Current Switch with Built-in Magnetic Blowout. Model Number Legend

Ordering Information. General-purpose Basic Switch X. Direct Current Switch with Built-in Magnetic Blowout. Model Number Legend General-purpose Basic Switch X Direct Current Switch with Built-in Magnetic Blowout Incorporates a small permanent magnet in the contact mechanism to deflect the arc to effectively extinguish it. Ideal

More information

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

For full product information, visit  Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. Safety Interlock Switches D4S-N D4SN For full product information, visit www.sti.com. Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. Slim Safety Door Switches with

More information

Various applications. Robust housing. The GX-4S uses a robust stainless steel housing. The tightening torque can be 0.58 N m or less.

Various applications. Robust housing. The GX-4S uses a robust stainless steel housing. The tightening torque can be 0.58 N m or less. INUCTIVE SERIES Compact Inductive Proximity Sensor Flexible cable Metal embedding type available possible Amplifier Built-in High functionality together with robust housing and flexible cable GA-/GH -N

More information

Cable length. 3: 3 m. 4: Adjustable mounting (vertical) 4: 3NC (slow action) 5: 5 m. (Slow-action) Horizontal 1 m D4GS-N1R D4GS-N2R D4GS-N3R D4GS-N4R

Cable length. 3: 3 m. 4: Adjustable mounting (vertical) 4: 3NC (slow action) 5: 5 m. (Slow-action) Horizontal 1 m D4GS-N1R D4GS-N2R D4GS-N3R D4GS-N4R Slim Safety-Door Switch Industry s Smallest Safety-Door Switch (with 3 Contacts) for Use in Space-Confined Areas Slim body design (85 x 30 x 17 mm) suitable for small door applications 2-contact and 3-contact

More information

Safety-door Switch. Ordering Information

Safety-door Switch. Ordering Information Safety-door Switch Safety-door Switch s Special Operation Key Positively Pulls Apart the Contacts from Each Other and Contributes to the Safety of the Production Site Special Operation Key prevents mis-operation.

More information

F111.X Flow Sensor for Hot Tap Installation INSTRUCTION MANUAL. 1. Introduction Safety Instructions Unpacking Description.

F111.X Flow Sensor for Hot Tap Installation INSTRUCTION MANUAL. 1. Introduction Safety Instructions Unpacking Description. F111.X Flow Sensor for Hot Tap Installation INSTRUCTION MANUAL EN 08-05 Table of Contents 1. Introduction 2 1.1. Safety Instructions 2 1.2. Unpacking 2 2. Description. 2 2.1. Main Features.. 3 2.2. Technical

More information

台灣黑馬牌指示量表類 DIAL INDICATOR METROLOGY

台灣黑馬牌指示量表類 DIAL INDICATOR METROLOGY C1 C2 C3 Dial Gages (Small Bezel Dia) DG-9003S DG-9004S DG-9005S DG-9003S DG-9004S 0-3mm 0-4mm ψ40mm Aluminum Body ψ36mm Aluminum Body DG-9005S 0-5mm ψ40mm Aluminum Body Dial Gages (Normal) DG-9010A DG-9010R

More information

VL (AZ8) Limit Switches

VL (AZ8) Limit Switches COMPACT SIZE LIMIT SWITCHES VL (AZ8) Limit Switches A compact and accurate vertical limit switch. Switches with indicator lamp available for convenient maintenance; either a neon AC powered lamp or an

More information

DC2-Wire Regular Cylindrical Proximity Switches

DC2-Wire Regular Cylindrical Proximity Switches DC-Wire Regular Cylindrical Proximity Switches FL7M Series Rigid structure, highly waterproof DC -wire switches with improved visibility of lamps. DC -wire, for reduced wiring costs. Stable sensing area

More information

SPECIAL TOOLS. Core Drilling Machines SERVICE MANUAL. Page 1

SPECIAL TOOLS. Core Drilling Machines SERVICE MANUAL. Page 1 SPECIAL TOOLS Core Drilling Machines Page 1 SERVICE MANUAL Service Manual Necessary Tools for machine assembly BEAST by BBTEC Core Drilling Machines 1 Soft Hammer (preferred plastic head) Art. 6.512.096

More information

Becker Precision Equipment

Becker Precision Equipment Becker Precision Equipment HPP-SB Series Pneumatic Valve Positioner HPP-SB Pneumatic Positioners Provide Accurate Positioning of Single-Acting Actuated Control Valves Description The Becker Model HPP-SB

More information

Inductive Proximity Sensor

Inductive Proximity Sensor Inductive Proximity Sensor General-purpose Type in a Basic Switch Housing Mounting pitch compatible with that of mechanical basic switch. Wide operating voltage range: 10 to 30 VDC or 90 to 250 VAC. LED

More information

D4GS-N CSM_D4GS-N_DS_E_7_2

D4GS-N CSM_D4GS-N_DS_E_7_2 Slim Safety Door Switch D4GS-N CSM_D4GS-N_DS_E_7_2 Slim Safety Door Switches with IP67 Rating Slim design with a width of only 17 mm (three-contact models). Reversible design allowing either front or rear

More information

Life PERFORMANCE Catalog listing Standards Structure Electrical performance Mechanical performance Ambient operating conditions Recommende tightening

Life PERFORMANCE Catalog listing Standards Structure Electrical performance Mechanical performance Ambient operating conditions Recommende tightening SPATTER-GUARDED SWITCHES Model LS Effective countermeasures against the adhesion of spatter. UL/CSA/GB(CCC marking)-approved. (excluding some models) ORDER GUIDE Actuator Name Roller lever type Shape Max.

More information

Operation mode. Sensing distance N.O. N.C. N.O. N.C. N.O. N.C. 7mm

Operation mode. Sensing distance N.O. N.C. N.O. N.C. N.O. N.C. 7mm 6 Specifications FL7N/M Series DC 2-wire Type (shielded/unshielded) Cylindrical Proximity Sensors FEATURES Rigid Structure, Highly Water-proof DC 2-wire Type with Improved Visibility Indicator Lamps. DC

More information

WL-N/WLM-N. Two-circuit Limit Switch/Long-life Two-circuit Limit Switch

WL-N/WLM-N. Two-circuit Limit Switch/Long-life Two-circuit Limit Switch Two-circuit Limit Switch/Long-life Two-circuit Limit Switch WL-N/WLM-N Select the Best Two-circuit Switch for the Operating Environment and Application from a Wide Range of Models A wide selection of models

More information

Clamping Tools

Clamping Tools Clamping Tools Drill chuck Tapping chuck/ tapping machines Taper bore tools HSK inserts Tool holder for lathes Tool pre-setter 1 1.3 1.8 Reduction sleeves Spindle Sleeves Ejector Drifts Adapter sleeves

More information

D4SL. Safety Interlock Switches. Compact 6-Contact Guard Lock Safety-Door Switch NEW! Specifications. Standards and EC Directives

D4SL. Safety Interlock Switches. Compact 6-Contact Guard Lock Safety-Door Switch NEW! Specifications. Standards and EC Directives Safety Interlock Switches DSL Compact -Contact uard Lock Safety-Door Switch Two types are available: a connector type that reduces wiring time and a detachable terminal block type. Robust and durable metal

More information

D4DS. Compact Interlock Safety Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. Refer to Precautions on page 9.

D4DS. Compact Interlock Safety Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. Refer to Precautions on page 9. Compact Interlock Safety Door Switch Compact Safety Switch Saves Space and is Ideal for a Variety of Doors Positive opening mechanism and double insulation approved by TÜV and BIA. Five-direction Operation

More information

Small Limit Switch D4V

Small Limit Switch D4V Small Limit Switch DV Compact Vertical Models Sized for Asian Standards Compact new design approximately / the size of OMRON vertical Limit Switches. Structure enables the terminal section to be fully

More information

D4DS. Safety-Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. H Conforms to EN (TÜV) standards.

D4DS. Safety-Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. H Conforms to EN (TÜV) standards. Safety-Door Switch Compact Safety Switch Saves Space and is Ideal for a Variety of Doors H Conforms to EN (TÜV) standards. (positive opening mechanism isindicatedonthe switch) H Wide standard operating

More information

GIRTH GEARS AND PINIONS OVERVIEW

GIRTH GEARS AND PINIONS OVERVIEW GIRTH GEARS AND PINIONS OVERVIEW Girth Gears & Pinions Tubular mills and rotary kiln operations are the life support system for the processing industries, and necessitates reliable and uninterrupted operations.

More information

PNEUMATIC SLIDES (SERIES ZA)

PNEUMATIC SLIDES (SERIES ZA) ZA PNEUMATIC SLIDES (SERIES ZA) Bore 2x6, 2x8, 2x12, 2x16 or 2x20 mm. Stroke from 10 mm to 150mm. Optional end of stroke adjustments using shock absorbers, rubber bumpers, (FGD) or grub screw, (FPD). Optional

More information

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information Safety-door Switch Safety-door Switch s Special Operation Key Directly Pulls Apart the Contacts from Each Other and Contributes to the Safety of the Production Site Conforms to EN (TÜV) standards corresponding

More information

FL7MSeries. DC2-Wire Regular Cylindrical Proximity Sensors

FL7MSeries. DC2-Wire Regular Cylindrical Proximity Sensors DC-Wire Regular Cylindrical Proximity Sensors FL7MSeries Rigid structure, highly waterproof DC -wire sensors with improved visibility of lamps. DC -wire, for reduced wiring costs. Stable sensing area is

More information

Linear Torque Limiting Clutch

Linear Torque Limiting Clutch LM Series Features & Options Linear Torque Limiting Clutch Innovation Description & Operation Sankyo's LM Series offers adjustable torque limiting in any linear axis. It mounts directly to linear slide

More information

Features. 2-wire type available. Max. operation distance: 1.5 mm 0.06 in (Stable sensing range 0 to 1.2 mm 0.05 in)

Features. 2-wire type available. Max. operation distance: 1.5 mm 0.06 in (Stable sensing range 0 to 1.2 mm 0.05 in) 817 Cylindrical Inductive Proximity Sensor SERIES Related Information General terms and conditions... F-3 Glossary of terms...p.1576~ guide... P.781~ General precautions... P.1579~ PHOTO PHOTO panasonic.net/id/pidsx/global

More information

DIAL SNAP GAUGE. dial indicator is not included W. optional indicators

DIAL SNAP GAUGE. dial indicator is not included W. optional indicators DIAL SNAP GAUGE dial indicator is not included 36 A 2 215-25W anvil Ø15 B 11 anvil 14 For quick Go/No-Go judgment of diameter of cylinders and shafts Anvil retracting stroke: 3mm Measuring force: 6-9N

More information

VL (AZ8) Limit Switches

VL (AZ8) Limit Switches COMPACT SIZE LIMIT SWITCHES Limit Switches A compact and accurate vertical limit switch. Type with a lamp which makes maintenance convenient; either a neon AC powered lamp or an LED DC powered lamp. With

More information

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure.

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure. Guard Lock Safety-door Switch Protective Doors Are Locked Until Machines Completely Stop Operating A mechanical lock is applied automatically when the Operation Key is inserted. A high level of safety

More information

NFPA Double acting imperial cylinders

NFPA Double acting imperial cylinders > > Ø 4... 8 > > Adjustable captive cushion needle > > Constructed of the finest materials > > Magnetic piston standard > > Wide temperature range > > Shock and vibration tested to N 61373, Category 1,

More information

Crossed Roller Ways. Description of each series and Table of dimensions. Anti-Creep Cage Crossed Roller Way

Crossed Roller Ways. Description of each series and Table of dimensions. Anti-Creep Cage Crossed Roller Way Crossed Roller Ways Description of each series and Table of dimensions Crossed Roller Way Page - to -7 Anti-Creep Cage Crossed Roller Way Page - to - Crossed Roller Way Unit Page - to - In the table of

More information

INTEGRATED HYDRAULIC BRAKE ACTUATORS

INTEGRATED HYDRAULIC BRAKE ACTUATORS INTEGRATED HYDRAULIC BRAKE INTEGRATED HYDRAULIC BRAKE INTEGRATED HYDRAULIC BRAKE The integrated hydraulic brake is comprised of a pneumatic cylinder that acts as an actuator and an oleo-dynamic circuit

More information

Steering Gear: Service and Repair POWER STEERING GEAR BOX

Steering Gear: Service and Repair POWER STEERING GEAR BOX 2003 Kia Truck Sorento V6-3.5L Copyright 2013, ALLDATA 10.52 Page 1 Steering Gear: Service and Repair POWER STEERING GEAR BOX COMPONENTS REMOVAL 1. Drain the power steering fluid. 2. Disconnect the pressure

More information

Linear actuators ILA Series

Linear actuators ILA Series Linear Actuator ILA Series without input drive, with flange and input shaft Linear Actuator ILA Series with input drive - with 2 bevel gearmotors - with single bevel gearmotor - with helical coaxial or

More information

GXL SERIES. High performance in micro-size design. Micro-size Inductive Proximity Sensor PROXIMITY SENSORS INDUCTIVE. Wide model variety

GXL SERIES. High performance in micro-size design. Micro-size Inductive Proximity Sensor PROXIMITY SENSORS INDUCTIVE. Wide model variety SERIES Micro-size Inductive Proximity -wire available PNP output Oil resistant Flexible cable Different freq. available available available Amplifier Built-in High performance in micro-size design GA-/GH

More information

Limit Switches with Positive Opening Mechanism

Limit Switches with Positive Opening Mechanism Limit Switches with Positive Opening Mechanism LJA Series Positive opening mechanism Snap action limit switches with positive opening mechanism enables general industrial machines to comply with EC directives

More information

Limit switches. 6 Thermoplastic roller lever 1 direction of actuation SEN TRONIC AG. Presentation

Limit switches. 6 Thermoplastic roller lever 1 direction of actuation SEN TRONIC AG. Presentation Presentation Variable composition Spring-rod lever with thermoplastic end () Spring-rod lever, metal () Variable length thermoplastic roller lever () Round rod lever, thermoplastic, Ø mm L = mm () ZCK

More information

GX-5SU(B) is just 5.4mm in diameter, the smallest in existing DC two-wire sensors. It saves you space. GX-12ML(B) Conventional model

GX-5SU(B) is just 5.4mm in diameter, the smallest in existing DC two-wire sensors. It saves you space. GX-12ML(B) Conventional model SERIES DC -wire Cylindrical Inductive Proximity High Performance & Ease of Use Marked Conforming to EMC Directive Robust in Tightening The tightening torque has been improved to approx. four times greater

More information

Ex.: Special spatter-resistant coating

Ex.: Special spatter-resistant coating Stainless Steel Sensing Face Proximity Sensor FL7SSeries The FL7S is a proximity sensor having a stainless steel sensing face and housing, and is specially designed for welding applications on the automobile

More information

Flow Switch Diaphragm Style Flow Switch IFW5 10 N Diaphragm style flow switch. Thread type. Nil. Body size Note)

Flow Switch Diaphragm Style Flow Switch IFW5 10 N Diaphragm style flow switch. Thread type. Nil. Body size Note) [Option] The flow switch, series IFW is used for detection and confirmation of the flow as a relaying device for the general water applications in some various equipment such as cooling water fixture in

More information

Compact Size: "5.4mm. GX-5SU(B) is just 5.4mm in diameter, the smallest in existing DC two-wire sensors. It saves you space.

Compact Size: 5.4mm. GX-5SU(B) is just 5.4mm in diameter, the smallest in existing DC two-wire sensors. It saves you space. INDUCTIVE SERIES DC -wire Cylindrical Inductive Proximity G-8H/8H G-N G-8U G-6 Robust in Tightening The tightening torque has been improved to approx. four times greater than that of conventional models

More information

Operation Key D4BS - K Head Mounting Direction F: Four mounting directions possible (front-side mounting at shipping)

Operation Key D4BS - K Head Mounting Direction F: Four mounting directions possible (front-side mounting at shipping) Safety-door Switch D4BS The Special Activates a Direct Opening Mechanism to Open the Contacts and Shut Off Control Circuits when Protective Doors Are Opened on Machine Tools or Other Equipment CSM_D4BS_DS_E_6_1

More information

Rectangular-shaped Inductive Proximity Sensor.

Rectangular-shaped Inductive Proximity Sensor. 69 PHOTO PHOTO Rectangular-shaped Inductive Proximity Sensor -F/H SERIES Related Information Amplifi er General terms and conditions... P.1 Sensor selection guide...p.11~ / P.67~ Glossary of terms... P.19

More information

! Contact our sales office regarding a delivery date or a price since this is a special model. Auto switch D-M9 series mountable

! Contact our sales office regarding a delivery date or a price since this is a special model. Auto switch D-M9 series mountable ! Contact our sales office regarding a delivery date or a price since this is a special model. P.G.Information (Specialized Product) Electric Stopper Cylinder/LEBH-X3 Series SP147X-019E-1 RP:SX SMC Corporation

More information

Return To Main Table of Contents GENERAL... 2 STRUT ASSEMBLY LOWER ARM STABILIZER BAR CENTER MEMBER WHEEL AND TIRE...

Return To Main Table of Contents GENERAL... 2 STRUT ASSEMBLY LOWER ARM STABILIZER BAR CENTER MEMBER WHEEL AND TIRE... FRONT SUSPENSION Return To Main Table of Contents GENERAL... 2 STRUT ASSEMBLY... 11 LOWER ARM... 13 STABILIZER BAR... 17 CENTER MEMBER... 19 WHEEL AND TIRE... 21 GENERAL GENERAL SPECIFICATIONS Suspension

More information

INDEX. PAGE Adjustment mechanism for radial position of block on rotating

INDEX. PAGE Adjustment mechanism for radial position of block on rotating INDEX Adjustment mechanism for radial position of block on rotating arm 520 Amplifying mechanism for precision measuring instruments--491 Angular movement, crank and link mechanisms for increasing 251,

More information

High sensitivity. Low current load type. type. Short plunger ~ Fine plunger ~ ~ Lever ~ Roller lever ~ Short roller lever ~

High sensitivity. Low current load type. type. Short plunger ~ Fine plunger ~ ~ Lever ~ Roller lever ~ Short roller lever ~ 6 BZ, BA, BE Series Specifications Standard Basic Switches FEATURES These Switches are Used Extensively and Have Earned the High Respect of Our Customers. Standard basic switches (BZ, BA, BE Series) are

More information

Double insulated, types XCK-P and XCK-T. With head for linear movement (plunger) operators

Double insulated, types XCK-P and XCK-T. With head for linear movement (plunger) operators Double insulated, types XCK-P and XCK-T Presentation XCK-P with 1 cable entry, conforming to CENELEC EN 57 With head for linear movement (plunger) operators Page 18 With head for rotary movement (lever)

More information

Correction Reissue. Product Discontinuation Notices. Discontinuation Notice of Cylindrical Proximity Sensor Model E2E series.

Correction Reissue. Product Discontinuation Notices. Discontinuation Notice of Cylindrical Proximity Sensor Model E2E series. PRODUCT NEWS Correction Reissue Product Discontinuation Notices Proximity Sensors Issue Date August 4, 2014 No. 2014038CE(3) Discontinuation Notice of Cylindrical Proximity Sensor Model E2E series.

More information

Instruction Manual. LG-100 Series Pointer-type Liquid Level Gauge

Instruction Manual. LG-100 Series Pointer-type Liquid Level Gauge Instruction Manual LG-100 Series Pointer-type Liquid Level Gauge Thank you for choosing our product. Our liquid level gauge is designed and produced, based on the specification of installation and measurement

More information

SIRIUS 3RU2 Thermal Overload Relays

SIRIUS 3RU2 Thermal Overload Relays Overview 1 2 3 4 6 1 2 NSB0_0207a Connection for mounting onto contactors: Optimally adapted in electrical, mechanical and design terms to the contactors. The overload relay can be connected directly to

More information

Model Pressure range ON/OFF output Linear output

Model Pressure range ON/OFF output Linear output Digital Sensor Sensor with Easy-to-Read LED Display status can be checked at a glance from the red digital pressure value and analog bar displays. Measurement pressure is averaged by the chattering prevention

More information

V160C. Mould Hydraulic Systems. Hydraulic cylinders-iso 6020/2 compact 160 bar V160C

V160C. Mould Hydraulic Systems. Hydraulic cylinders-iso 6020/2 compact 160 bar V160C V160C Mould Hydraulic Systems Hydraulic cylinders-iso 6020/2 compact 160 bar V160C V160Ccat.GB01-2006 Hydraulic cylinders-iso 1 2 Chrome-plated steel rod, hardened or tempered and polished. Thickness of

More information

RPFS. ROTA PULSE FLOW SENSOR (Slip Insertion Paddlewheel) DATASHEET FEATURES

RPFS. ROTA PULSE FLOW SENSOR (Slip Insertion Paddlewheel) DATASHEET FEATURES FEATURES ROTA PULSE FLOW SENSOR (Slip Insertion Paddlewheel) DATASHEET ± 2.5% accuracy @ velocity range 0.5 to 8.5 m/sec. ± 1 % accuracy over linear range 0.7 to 7.0 m/sec. Repeatability of ±0.6%. NPN

More information

CL50 Column Light Features

CL50 Column Light Features CL50 Column Light Multi-Color General Purpose or Audible Indicators Features Rugged, cost-effective and easy-to-install multi-color indicators Illuminated light provides easy-to-see operator guidance and

More information

D4BS CSM_D4BS_DS_E_8_4

D4BS CSM_D4BS_DS_E_8_4 Safety-door Switch CSM DS_E_8_4 The Special Activates a Direct Opening Mechanism to Open the Contacts and Shut Off Control Circuits when Protective Doors Are Opened on Machine Tools or Other Equipment

More information

> clamping force up to kn. > operating pressure up to 500 bar. > piston with internal thread. > for push- and pull operation

> clamping force up to kn. > operating pressure up to 500 bar. > piston with internal thread. > for push- and pull operation Block CYLINDERS for VARIOUS DESIGN APPLICATIONS > clamping force up to 155.5 kn > operating pressure up to 500 bar > piston with internal thread > for push- and pull operation > with longitudinal and cross

More information

High-speed detection even a little liquid leak

High-speed detection even a little liquid leak 737 Leak Sensor Related Information Amplifier Built-in EX-F70 SERIES SERIES Sensor selection guide...p.11~ / P.77~ General terms and conditions...p.1 General precautions...p.986~ PHOTO PHOTO Conforming

More information

Small Tool Instruments and Data Management

Small Tool Instruments and Data Management Small Tool Instruments and Data Management Dial Gauge Stands Pages 268 272 Comparator Stands Pages 273 274 Joint Magnetic Stands Concentricity testers Pages 275 280 Angulometers, steel squares Pages 281

More information

Recommended spare parts and often used accessories

Recommended spare parts and often used accessories Recommended spare parts and often used accessories Electric Actuators Rotary Actuators 2SA5 Linear Actuators 2SB5 Part-turn Actuators 2SC5 and 2SG5 for types 2 S 5 - - 3 4 Issue 07.14 Subject to changes

More information

Mining & Construction Tools. Technical Information for Brazed Tools. General Cutting Tools. Rotating Brazing Tools

Mining & Construction Tools. Technical Information for Brazed Tools. General Cutting Tools. Rotating Brazing Tools BRAZED TOOLS Technical Information for 02 KORLOY Ultra-Fine Grades : F-Series 02 Corrosion & Magnetism Proof Grade : IN-Series General Cutting Tools 03 Cemented Carbide, Cermet Blank 04 Square Blank 06

More information

Compact Inductive Proximity Sensor. onlinecomponents.com. Various Applications

Compact Inductive Proximity Sensor. onlinecomponents.com. Various Applications INUCTIVE SERIES Compact Inductive Proximity -N -U G-8H/8H G-N G-8U G-6 Miniature -S is an amplifier built-in inductive proximity sensor having a diameter of just ".8mm. -S ".8mm Various Applications The

More information

Barrel Size Metal Barrel Plastic Barrel. 5 Nm (3.7 ft-lb) 10 Nm (7.4 ft-lb) 15 Nm (11 ft-lb) 25 Nm (18 ft-lb) 90 Nm (66 ft-lb) 90 Nm (66 ft-lb)

Barrel Size Metal Barrel Plastic Barrel. 5 Nm (3.7 ft-lb) 10 Nm (7.4 ft-lb) 15 Nm (11 ft-lb) 25 Nm (18 ft-lb) 90 Nm (66 ft-lb) 90 Nm (66 ft-lb) Mounting TURCK inductive proximity sensors are manufactured with a shielded coil, designated by Bi in the part number, and a nonshielded coil, designated by Ni in the part number (See page C7). Embeddable

More information

Parallel Grippers- DPW DIRECTCONNECT Wide Body Series

Parallel Grippers- DPW DIRECTCONNECT Wide Body Series DPW SERIES 1.196 Parallel Grippers- DPW DIRECTCONNECT Wide Body Series DIRECTCONNECT Connectivity: DIRECTCONNECT Tapped and Dowel mounting on body. Large or Wide Parts: Wide body design provides secure

More information

Operating instructions Mechatronic flow sensor SBY /00 03/2011

Operating instructions Mechatronic flow sensor SBY /00 03/2011 Operating instructions Mechatronic flow sensor SBY357 UK 7060/00 03/011 Contents 1 Safety instructions... Functions and features...3 3 Installation...3 4 Electrical connection...4 5 Switch point setting...4

More information

mechanics LES functional overview LES 4 LES 6 LES 5

mechanics LES functional overview LES 4 LES 6 LES 5 LES functional overview LES 4 with spindle drive Overview 2-54 2-56 LES 6 2-58 with spindle drive LES 5 2-60 with spindle drive Calculations 2-62 Combination examples Motor modules Clutch housing Motor

More information

Model Pressure range ON/OFF output Linear output

Model Pressure range ON/OFF output Linear output Authorised Distributors:- ASH & ALAIN INDIA PV LD S-1, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-112(India) el : 11-43797575 Fax : 11-43797574 E-mail : sales@ashalain.com Digital Sensor Sensor

More information

2NC (slow-action) Direct. Model. opening

2NC (slow-action) Direct. Model. opening Small Safety Limit Switch CSM DS_E_3_1 Smallest Class of Safety Limit Switches in the World Note: Contact your sales representative for details on models with safety standard certification. The world's

More information

U-CENTER. NC heads for facing, boring, threading and radiusing for machining centres

U-CENTER. NC heads for facing, boring, threading and radiusing for machining centres U-CENTER NC heads for facing, boring, threading and radiusing for machining centres 8 U-CENTER General features o + 4 1 A U-CENTER U-CENTER boring and facing heads are designed for use on machines with

More information

* E8MS-N1 is only 1-channel pressure sensor controller. E80-C2 can be used. For more details, please refer to E80 catalogue.

* E8MS-N1 is only 1-channel pressure sensor controller. E80-C2 can be used. For more details, please refer to E80 catalogue. Authorised Distributors:- ASH & ALAIN INDIA PVT LTD S-, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-(India) Tel : -7977 Fax : -7977 E-mail : sales@ashalain.com Sensor Four-Input-Channel Sensor

More information

G7L. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops. Application Examples. Model Number Legend

G7L. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops. Application Examples. Model Number Legend A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops No contact chattering for momentary drops up to % of rated. Wide-range AC-activated coil that handles 1 to 1 or to

More information