Fusegear for Semiconductor Fuse
|
|
- Jeffrey Hodges
- 5 years ago
- Views:
Transcription
1 Fusegear for Semiconductor Fuse IP 20.SI
2 Bases for PSC ranges: SI TT, SI 000/00, SI DIN SI TT for stud-type fuses SI 00 for bracket-type fuses STANDARD VERSION SI FUSEHOLDERS FOR STUD-TYPE FUSES, FOR BLADE-TYPE FUSES SI 00 AND SI 000, FOR BRACKET-TYPE FUSESSI DIN 80 AND DIN 110 SI 000 for bracket-type fuses SI DIN 80 and 110 for blade-type fuses MOUNTING IN ONE-POLE FUSEHOLDER SIMPLIFIES FUSE REPLACEMENT FOR INSTALLATIONS CONNECTED WITH CABLES AND BARS FOR TTF STUD-TYPE FUSES FOR BLADE AND BRACKET-TYPE FUSES AS PER DIN 4353 STANDARD SIZES: , 80 MM BETWEEN AXES SIZES: , 80 AND 110 MM BETWEEN AXES FOR TTF VERSION STUDS ARE DELIVERED WITH THE FUSE HOLDER FINGER SAFE VERSION AVAILABLE Main characteristics Designation Insulation voltage Ui (AC 50/0 Hz & DC) (V) Rating Current (A) Maximum power* (W) Dielectric withstand test RMS voltage 1 mn 50/0 Hz (kv) Impulse voltage 1.2/50ms (kv) Fire and fumes class SI TT / V SI TT 70/ V UL 94 VO SI TT 32/ V SI TT 72/ V SI 000 DIN V UL 94 VO SI 00 DIN V UL 94 VO SI DIN 80 ( to 33) 1500 V SI DIN 110 ( to to 73) 1500 V SI DIN ( to 33) 1500 V UL 94 VO SI DIN ( to to 73) 1500 V Vibration withstand for standard version: Tests with sine vibrations carried out at ambient with scanning each of the three main axes of the holder. Spectrum: 1 st segment (2 to 1 Hz) constant displacement x = 5 mm peak. 2 nd segment (1 to 0 Hz) constant acceleration = 5 g peak. Exponential scanning speed: 1 octave per minute. Duration: 2 hours per axis. FG208
3 Bases for PSC ranges: SI TT, SI 000/00, SI DIN STANDARD VERSION SI FUSEHOLDERS Reference and catalog numbers Designation Ref. Number Weight (g) SI TT /31 B SI TT 70/71 C SI TT 32/33 D SI TT 72/73 E SI 000 DIN 80 C SI 00 DIN 80 Q C - CLO* M SI DIN 80 L SI DIN 110 F SI DIN F SI DIN L Packaging Catalog Number SITT/31 SITT70/71 SITT32/33 SITT72/73 SI000DN80 SI00DN80 CLO SIDN80A SIDN110A SIDN8010A SIDN11010A * Necessary for SI 00 DIN 80 one-pole mounting. Distance X Between Poles Axes (Without Partition) Designation Fuses sizes Operating voltage U 0V 550V 90V 1000 V 10 V SI TT /31-31 SI TT 70/ , SI TT 32/ SI TT 72/ ,5 84,5 88,5 94,5 99,5 SI 000 DIN SI 00 DIN ,5 4,5 4, SI DIN , / ,5 84,5 88,5 94,5 99,5 SI DIN , / ,5 84,5 88,5 94,5 99,5 X FG209
4 Bases for PSC ranges: SI TT, SI 000/00, SI DIN Connection dimensions SI TT STANDARD VERSION SI FUSEHOLDERS D Designation A B C D E G L M F SI TT /31 118() 83 () 42() 123(31) (31) 51(31) 4 50, 202 M8 57 SI TT 70/71 118(70) 83 (70) 42(70) 123(71) (71) 51(71) M8 7 SI TT 32/33 137(32) 93 (32) 0(32) M10 (32) 145(33) , (33) 75(33) M12 (33) 57 SI TT 72/73 137(72) (72) 0(72) M10 (32) 145(73) (73) 75(73) M12 (33) 7 Partition mounting not possible. Panel drilling: x mm SI 00 DIN 80 SI 000 DIN 80 Catalog Number Designation A B C D E G L Fuse sizes Catalog Number SI 000 DIN x49-27x0 DIN x0 SI 00 DIN DIN 80 Partition mounting only for SI 00 DIN 80 * Electrical connection of fuse and fuse holder via supplied studs, nuts and washers Maximum recommended tightening torque: 13.5 Nm for M8 screws. 2 Nm for M10 screws. 4 Nm for M12 screws. - Fixing of base on plate or bar via screws not supplied. M for SI 000 and SI 00 Tightening torque 7 ± 15 Nm. M8 for SI TT Tightening torque 10 ± 2 Nm. FG210
5 Bases for PSC ranges: SI TT, SI 000/00, SI DIN STANDARD VERSION SI FUSEHOLDERS SI DIN Note: Screws for fixing fuse on holder do not jut out above or modify insulation distance when fuse connected. Designation a e1 b c Fuse Size Catalog Number SI DIN SI DIN SI DIN SI DIN Partition mounting impossible 93.5 D D D D D D D D D D D D D D D D11 * Electrical connection of fuse and wires by M10x screws made in plated steel minimum 8-8 class. Screws included. + 0 Maximum recommended tightening torque: 44 Nm for M10 screw Fixing of base with screws not supplied: M8. Tightening torque 10 ± 2 Nm. FG211
6 Applications: Main characteristics Fusegear, for semiconductor fuse square body Highlights: IP20 Touch Safe SI Fuse holders for stud-type fuses, for blade-type fuses SI 00 and SI 000 for bracket-type fuses SI DIN 80 and DIN 110 Mounting in one-pole IP 20 fuseholder simplifies fuse usage outside convertisers for installations connected with cables and bars. For TTF stud-type fuses For blade and bracket-type fuses as per DIN 4353 standard sizes : 80 mm between axes sizes : 80 and 110 mm between axes Suitable with or without microswitches installed on fuses. Fixation on rail or by screw. Dielectric withstand test Insulation voltage Maximum IP 20 Fuse RMS Impulse Fire and smokes Fuse blocks UI Current operating voltage voltage (AC 50/0 Hz & DC) current 1mn 50:0 Hz 1,2/50 Class microsec SI TT / V 1000 A 10 kv 12 kv SI TT 70/ V 1000 A 10 kv 12 kv UL 94 VO SI TT 32/ V 00 A 10 kv 12 kv SI TT 72/ V 00 A See following 10 KV 12 kv SI 000 DIN V 0 A page 7 kv 8 kv UL 94 VO SI 00 DIN V 0 A 8 kv 12 kv UL 94 VO SI DIN 80/ ( TO 33) 1500 V 00 A 10 kv 12 KV SI DIN 110/ UL 94 VO 1500 V 00 A 10 kv 12 kv ( TO TO 73) Vibration withstand: Tests with sine vibrations carried out at ambient with scanning each of the three main axes of the holder. Spectrum :1 st segment (2 to 1 Hz) constant displacement x = 5 mm peak. 2 nd segment (1 to 0 Hz) constant acceleration g = 5g peak. Exponential scanning speed : 1 octave per minute. Duration : 2 hours per axis. FG212
7 Fusegear, for semiconductor fuse square body References Catalog Numbers Sizes Impossible to use Micrositch Micrositch can be used TTF DIN 80 DIN 110 TTF DIN 80 DIN B V22772 SI000FS1DN80R SI000FS1DN80RM 00 C W22773 SI00FS1DN80R SI00FS1DN80RM N P3207 SI-31FS1TTR L X SI- 31 SI- SI FS1TTRM E S FS1DN80R 2FS1DN11R SI0-3FS1DN11RM 32 SI33FS1DN80RM SI32FS1TTR V Y R C32070 SI32- SI33FS1TTR SI33FS1DN80RM SIO-3FS1DN11RM 33FS1TTRM 70 A D X SI70-71 SI70-71FS1TTR SI FS1TTRM C FS1DN11R SI0-3FS1DN11RM 72 J SI72-73FS1TTR at 90V Ie = 220 Arms (IRMS in application) Packaging: 3 pieces. Outlet drawings C32070 SIO-3FS1DN11RM F3207 SI72 73FS1TTRM SI00FS1DN80R 185 SI00FS1DN80RM , ,5 3, Screws H MB Screws H MB- FG213
8 SI000FS1DN80R Outlet drawings 185 SI000FS1DN80RM ,5 92 3, Screws H MB Screws H MB- 80 SI-31FS1TTR 0 SI32FS1TTR / SI33-31FS1TTR 123 0/ M / / without IP 20 Protection FG214
9 Outlet drawings SI70-71FS1TTR 0 SI72-73FS1TTR 270 M D Taille D M SI-31FS1TTRM 270 SI32-33FS1TTRM Taille D M without IP 20 Protection FG215
10 Outlet drawings SI70-71FS1TTRM SI72-73FS1TTRM M8 M M10 D Taille D M SI-33-FS1DN80RM SI-32FS1DN80R M without IP 20 Protection FG21
11 Outlet drawings SI0-3FS1DN11RM SI0-1-2FS1DN11R M M Maximum fuse operating current Derating current for sizes 000 and 00 DIN 80 fuses used on IP 20 fuse holders I / I N Fuse holders Fuse nominal rating I (A) N Size 000 Size 00 90V grb 90V URB 90V grb 90V URB ,90 0,90 0,90 0, ,85 0,90 0, ,85 0,85 0 0,8 0, ,70 0, ,70 0,75 0 0,5 0, ,5 Note: limited at Ie = 220 Arms (IRMS in application) FG217
12 Maximum fuse operating current Derating current for 90V URD fuses sizes, 31, 32, 33 TTF, DIN 80, DIN 110 used on IP 20 fuse holders. I / I N Fuse holders Fuse nominal rating I N (A) 90V URD 90V URD 31 90V URD 32 90V URD , ,95 0 0,95 0,90 0, ,70 0,85 0, ,70 0,85 0,70 0, ,5 0,80 0,5 0,55 0,70 0,0 0, ,70 0,55 0, ,55 0,50 0, ,50 0, ,45 0, ,45 0, 10 0, 0, Maximum fuse operating current Derating current for 90V grb fuses sizes 70, 71, 72, 73 TTF and DIN 110 used on IP 20 fuse holders. I / I N Fuse holders Fuse nominal rating I N (A) 90V grb 70 90V grb 71 90V grb 72 90V grb , , ,95 0, ,85 0, ,95 0,85 0, ,80 0,70 0,70 0, ,5 0, , , ,50 FG218
13 Maximum fuse operating current Derating current for 10V URD fuses size 70, 71, 72, 73, TTF and DIN 110 used on IP20 fuse holders, consult us. FG219
Semiconductor Fuses Microswitches & Studs
MICROSWITCH SYSTEMS ADAPTED TO THE FOLLOWING FUSES: - PSC sizes 0,,, / 70, 7, 7, 7 - Blade-type PSC (PA) sizes 0-, - / 70, 7, 7, 7 - PSC sizes 000 / 00 New MS L -5 B6 MS PA -5 HIGHLY RESISTANT STUDS OFFERING
More informationSemiconductor (AC) fuses
PS ar sizes 9x - 500 V Main characteristics Ferraz Shawmut 500 V PS fuse-links provide maximum flexibility in equipment design and ultimate protection for today s power conversion equipment. These square
More informationSemiconductor (AC) fuses
Semiconductor () fuses PS ar sizes 9x - 500 V Main characteristics Ferraz Shawmut 500 V PS fuse-links provide maximum flexibility in equipment design and ultimate protection for today s power conversion
More informationSwitches. Fused Switches ITCP for Semiconductor Fuses 32 to 800A CONTROL: FUSE CONNECTING: SWITCHING: MECHANISM: FIXING: CONSTRUCTION:
Fused CONTROL: Side control, padlockable in off position by three padlocks. Safe and reliable of contact position on handles. SWITCHING: Double isolation per phase. Complete isolation of fuse when circuit
More informationSemiconductor (AC) fuses
Main characteristics 450 TO 700VAC / 63 TO 2800A Recognized Exceptionally low I 2 T, Watt losses. Non-magnetic construction, Highly reliable low voltage Trip-indicator system, conformity to UL, IEC, DIN
More informationNH Solid Blades 690 VAC sizes 000 to 3
NH Solid Blades 6 VAC sizes 000 to gs-class Protistor NH 6 VAC fuse-links provide maximum flexibility in equipment design and ultimate protection for today s power conversion equipment. This range is a
More informationTeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series
Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current
More informationonlinecomponents.com
66 grb 66 V AC grb - from up to 3 A Size: x38 The fuse preselection table below indicates: Fuse preselection Rated current Pre-arcing I²t Total I²t at 66VAC I N (A) I²t p (A²s) I²t (A²s) - rated current
More informationSemiconductor Fuses European Fuses
66 grb 66 V AC grb - from up to 3 A Size: x38 The fuse preselection table below indicates: Fuse preselection - rated current (or ) I N - pre-arcing I²t (I²t p ) at ms - total ope I²t (I²tt) at 66 V, cos
More informationSelector guide. PSC Square body fuses Size 3X VAC End Contact Terminals. Features and Benefits
Selector guide PSC Square body fuses Size 3X 500-700VAC End Contact Terminals December 2013 Issue 2 The IXYS UK range of 700V/690V protistor fuse links provides maximum flexibility in equipment design
More informationSelector guide. PSC Square body fuses Size 3X VAC Blade Terminals. Features and Benefits
Selector guide PSC Square body fuses Size X 500 700C Blade Terminals October 201 Issue 1 The IXYS UK range of 700/690 protistor fuse links provides maximum flexibility in equipment design and ultimate
More informationT CLASS T FUSE BLOCKS
Ferraz Shawmut Fuse Blocks accommodate fuses up to 600A. Insulators are either of durable, glassfilled polycarbonate (GFPC) or phenolic with verified dielectric strength in excess of 2500V. Ferraz Shawmut
More informationMotorized switch-disconnectors OTM 40 to 125 Amperes
Motorized switch-disconnectors OTM to 125 mperes With the new range of motorized-switch disconnectors, BB offers now a full range from to 2500 mperes. Thanks to the design, OTM...125 are a good solution
More informationThermal-Magnetic Circuit Breaker 2210-S291-P9M A
Thermal-Magnetic Circuit Breaker 0-S9-P9M-40033-...A Description Single pole thermal-magnetic circuit breaker with trip-free mechanism and toggle actuation. Two-chamber construction with cascade contact
More informationDX³ RCCBs - ID 4P up to 100 A
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ s - ID CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More information, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX 3 4500 A / 6 ka CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1
More informationGears & Fuse Gears. IEC General Purpose Fuses NH Fuses Plastic Bases 00-EP/TP. 690V Polyester fuse bases for NH fuse-links.
-EP/TP NH fuse bases are designed for fuse-links with rated voltages up to 69 V and VD. They are in compliance with IE 669, DIN VDE 66, part, and DIN 6 (dimensions). NH fuse bases are available for delivery
More informationPhase + Neutral, neutral on left side
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGE 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1
More informationCat N 3. OVERALL DIMENSIONS
Cat N Motor driven remote control module 87045 LIMOGES Cedex - FRANCE Telephone : + 33 5 55 06 87 87 Fax: + 33 5 55 06 88 88 Cat N : : 4 062 91 CONTENTS PAGE 1. Description - Use...1 2. Product range...1
More informationDNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DNX 3 MCB 4500 A / 6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation
More informationRX 3 MCB 4500 A Phase + Neutral, neutral on left side
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 RX 3 MCB 4500 A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More informationModulostar CMS10 Modular fuse-holders
Modulostar CMS10 FUSE HOLDERS, FUSE BASES AND SUPPORTS IEC CYLINDRICAL FUSE HOLDERS FEATURES & BENEFITS The innovative and comprehensive Modulostar range of Mersen fuse-holders. are finger-safe under IEC
More informationFuses for Semiconductor Protection European Standard Sizes 000 and 00. Protection of Power Semiconductors according to IEC and -4
URB Fuses for Semiconductor Protection European Standard Sizes 000 and 00 Class: ar Voltage ratings: AC 660 V AC 1000 V Current ratings: 16 A to 400 A Approvals: Standards: DIN 43653 IEC 60269-1 and -4
More informationHelioProtection HP15NH Photovoltaic fuse-links gpv 1500VDC
SPECIAL PURPOSE FUSES PHOTOVOLTAIC FUSES FEATURES & BENEFITS Mersen HP15NH photovoltaic (PV) fuse serie was engineered and designed specifically for the protection of photovoltaic systems. Helio-Protection
More informationSemiconductor (AC) fuses
x38 grb - 69VAC 69V AC grb - from up to 3 A Size: x38 The fuse preselection table below indicates: - rated current (or rating) I N - pre-arcing I 2 t (I 2 t p ) at ms - total operating I 2 t (I 2 tt) at
More informationPhase + Neutral, neutral on right side
87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX 3 MCB 6000 A / 10 ka Cat.. N (s): 4 074 67 / 68 / 69 / 70 / 71 / 72 / 73 / 74 / 75 / 76 / 77 / 78 / 79 ; 4 077 33 / 34
More informationNB1 Miniature Circuit Breaker
P-00 Modular DIN Rail Products MCB NB Miniature Circuit Breaker Color coded contact position indicator provides visual indication of the device status and insulation function Magnetic trip elements provide
More informationIEC & 2. Fuse holders with indicator light. Poles N N M M C Z D213627
MODULOSTAR CMS4, CMS IEC fuse holders: CMS 4 - Fuse holder compliant with IEC 09- &, and tested in accordance with IEC 0947- & for fuse disconnector usage IEC fuse disconnectors: CMS 4 - Fuse disconnectors
More informationTX³ RCCBs 2P up to 100 A
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 TX³ RCCBs CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More informationPower Supplies. PS5R Standard Series. PS5R Standard Series Switching Power Supplies Part Numbers
Standard Series Key features: Wide power range: 7.W-4W Universal input : 7.W-W: 8-264V /1-37V DC W: 8-2V /17-264V 24-37V DC (selectable) W, W, 24W: 8-264V /11-3V DC 4W: 3 phase: 32- V 3 phase: 3- V Overcurrent/overvoltage
More informationModular contactors and relays
pages /4 to / pages /8 and /9 pages /10 and /11 pages /12 and /13 Presentation and standards Presentation Designed for use in modular panels and enclosures, these contactors feature : i Easy installation
More informationProtistor size 31 ar 690VAC (IEC) / 700VAC (UL)
Protistor size 31 ar SEMICONDUCTOR PROTECTION FUSES SQUARE BODY HIGH-SPEED FUSE-LINKS AC PROTECTION FEATURES & BENEFITS Multiple body sizes and terminals or blades combination ar Class according to IEC
More information15 16 MCCBs for Power Distribution Technical Specification Frame 100A 250A 250A 400A 400A 630A 800 / 1000 / 1250 Type C DN0-100 D DN1-250 N DN2-250 D N S H DN3B-400 DN3-400 D N D N S V DN3-630 DN4-1250
More informationPSC SQUARE BODY 690/700 Volt SEMICONDUCTOR PROTECTION FUSES
PSC SQUARE BOY Ferraz Shawmut 690/700V PSC fuse-links provide maximum flexibility in equipment design and ultimate protection for today s power conversion equipment. These square body fuse-links are available
More informationFuse switch-disconnectors
Fuse switch-disconnector FH000 is intended for fuse-links with blade contacts size 000. It enables safe disconnection not only of rated current, but also overcurrent up to octuple rated current. A version
More informationThermal-Magnetic Circuit Breaker M1-...
Thermal-Magnetic Circuit Breaker 320-...-M-... Description Two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 6034). The addition of a magnetic tripping
More informationC -5 to +55 (0.8 to 1.1Uc) Permissible o
T - Line Contactors 3 & 4 Pole Contactors with C operating coils General Characteristics Type Unit TC1-D09 ~ TC1-D95 Rated insulation voltage (Ui) (Conforming to IEC 158-1) V 750 VDEO 110grC/IEC 60947-4
More informationMAKING MODERN LIVING POSSIBLE. Design Guide VLT MCD 100 Soft Starter the single speed drive
MAKING MODERN LIVING POSSIBLE Design Guide VLT MCD 100 Soft Starter the single speed drive Contents Contents 1.1.1 Introduction 2 1.2 Technical Data 3 1.3.1 Functional Diagram 4 1.3.4 Wiring 5 1.3.5 Adjustments
More informationDIN EN UL 508 / CSA 3RF A A 0 2
PMA Prozeß- und Maschinen-Automation GmbH Solid State Relays Zero-Point Switching, heatsink integrated Main Characteristics: Zero switching LED display Various connection technologies Plug-in control terminal
More informationFUSE-LINKS FOR PHOTOVOLTAIC APPLICATIONS
1 2 06 PML 10/14x85 1500V FUSE HOLDERS 08 CLIP CONTACT FOR φ10 FUSE LINKS 05 PMX & 14x51 FUSE HOLDERS 02 gpv & 14x51 600 &/1100 FUSE LINKS 03 gpv 1200 & 1500V FUSE LINKS 04 gpv NH1, NH2 & NH3 FUSE LINKS
More informationSpecial Purpose Fuses
Special Purpose Fuses Fuses for DC voltage applications www.eti.si ETI Elektroelement d.d. Obrezija 5, SI - 111 Izlake Slovenija Tel. + 38 03 5 57 570 Faks + 38 03 5 7 077 eti@eti.si NH DC 80 V - Telecom
More informationGears & Fuse Gears. Medium Voltage Fuses Clips. Clip lock design for CL-14 series. Mounting Details for Clip Lock Cat. No.
Clip lock design for CL-14 series Cat. No. 228-700-520 Cat. No. 228-700-530 (Pair at bottom) (Single at top) The Clip Lock design provides a reliable, high-pressure contact. Ferraz Shawmut CL-14 fuses
More informationSwitches for photovoltaic applications Disconnect switches, UL OTDC_U from 16 to 32 Amperes
Switches for photovoltaic applications Disconnect switches, UL OTDC_U from 16 to 32 Amperes OTDC16...32U - Compact efficiency OTDC from 16 to 32 amperes offers various DC voltage ratings and a control
More informationURDC-PV. Features and Benefits FUSES. URPV Fuses for PV Semiconductor Protection. gpv. Class: Voltage ratings: 600V DC to 1500V DC.
Fuses for PV Semiconductor Protection Class: gpv 0 Voltage ratings: 600V DC to 1500V DC Current ratings: 1 A to 450 A Standards: UL 2579 IEC 60 269-6 Approvals: E341342 E341490 Features and Benefits High
More informationR.C.B.O. SP / 1 module
87045 LIMOGES Cedex - France Telephone : (+33) 5 55 06 87 87 Fax : (+33) 5 55 06 88 88 R.C.B.O. SP / 1 module 6064 04 6064 64 05 6064 10 6064 11 6064 12 CONTENTS PAGES 1. Description, use... 1 2. Range...
More informationSynergy EN product information
Synergy EN60947-4-2 product information Rated operational voltages U e 200Vac to 480Vac Rated operational currents I e See Rating Table Rating index See Sizing Guide Rated frequency/frequencies 50-60Hz
More informationUltraSafe US22 Modular fuse-holders
UltraSafe US22 FUSE HOLDERS, FUSE BASES AND SUPPORTS UL/CSA FUSE HOLDERS FEATURES & BENEFITS The innovative and comprehensive UltraSafe range of Mersen fuse-holders. are finger-safe under IEC standards
More informationXB5AD33 SELECTOR SWITCH 230VAC 2AMP XB5 +OPTIONS
Characteristics SELECTOR SWITCH 230VAC 2AMP XB5 +OPTIONS Product availability : Stock - Normally stocked in distribution facility Price* : 68.00 USD Main Range of product Product or component type Device
More informationProtection and Connection Motorized and automatic transfer switches IEC Technical guide
Protection and Connection Motorized and automatic transfer switches IEC 61439 Technical guide Motorized change-over switches Uninterrupted power supply with motorized functionality ABB offers a wide variety
More information(1,5 modules per pole)
87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 DX 3 MCB 36kA, 80A CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More informationSolid State Relays, 3-phase
PMA Prozeß- und Maschinen-Automation GmbH Solid State Relays, 3-phase Zero-Point switching, heatsink integrated Main Characteristics: Three-phase controlled Zero switching LED display Various connection
More informationLEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1.
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 LEXIC MCB s DX-H 80A, 100A, 125A Curv urves B and C CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1
More informationSystem pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489
Data Sheet System pro M compact for branch circuit protection acc. to UL 489 2CDC021004S0014 2CDC021046S0014 The miniature circuit breaker SU200 M is BB s solution for UL 489 branch circuit protection
More informationModulostar US10 Modular fuse-holders
Modulostar US10 FUSE HOLDERS, FUSE BASES AND SUPPORTS UL/CSA FUSE HOLDERS FEATURES & BENEFITS The innovative and comprehensive Modulostar range of Mersen fuse-holders. are finger-safe under IEC standards
More informationSENTRON Switching and Protection Devices Switch Disconnectors
SENTRON Switching and Protection Devices Switch Disconnectors /2 Introduction 3K, 3KE, 3LD Switch Disconnectors 3K, 3KE Switch Disconnectors up to 1000 /4 General data /8 Floor mounting 3LD Main and EMERGENCY-STOP
More informationPower Supplies. Power Supplies. PS5R Standard Series. PS5R Standard Series Switching Power Supplies
Standard Series Standard Series Switching Part Numbers Part Number Item Watts Rated Voltage Rated Current -A V DC 1.A -A 7. V DC.6A -A24 24V DC.3A -B V DC 2.A Key features of the standard series include:
More informationFUSE BASES NH FUSE BASES 690V 160A 160A
fuse bases NH NH 14 690V NH 16 ACCESSORIES FOR NH 18 CR 690V NH 20 SECTIONABLE NEUTRAL NH BASES 21 BS FUSE SWITCH DISCONNECTORS 690V NH NH Fuse bases for NH fuse links. For mounting on DIN/EN rail or
More informationReduced Voltage Motor Starters
Reduced Voltage Motor Starters Soft Start Controllers. Solid-State Controllers Product Overview........................................ Type S70, Soft Start Controllers............................. Type
More informationINDUSTRIAL POWER SUPPLIES SFL-SERIES
INDUSTRIAL POWER SUPPLIES SFL-SERIES Operating Instructions 1. Application The SFL-series are compact, rugged switching power supplies designed for applications in process automation and other industrial
More informationK50H004UP cam changeover switch - 4-pole A - screw mounting
Characteristics cam changeover switch - 4-pole - 60-50 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing
More informationDX³ RCBO 4500/6 ka Phase + Neutral, neutral on left
87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX³ RCBO 4500/6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection...
More informationVarius SUMMARY OF MODELS
SUMMARY OF MODELS FH000 FH00 FH FH2 FH LTL4a Rated operating current I e 60 A 60 A 250 A 400 A 60 A 600 A Rated operating voltage AC/DC U e 690 V 690 V 690 V 690 V 690 V 690 V Size 000 00 2 4a Fuse-link
More informationCharacteristics TeSys contactors 0 TeSys k contactors and reversing contactors
90 Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors Environment characteristics Conforming to standards IEC 60947, NF C 63-110, VDE 0660, BS 5424 Product certifications LCp
More informationScheda prodotto Relè Series B
Relè di Potenza All-or-Nothing Relays designed to meet high power switching applications with up to three changeover contacts, rated 4000 or 7500 VA - AC1. They are ideally suited for arduous duties where
More informationATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A
Transfer switches The solution for > Genset < 90 kva > Heating systems > Climate control > Ventilation systems > Telecommunications atys-s_018_a Strong points Function products are 4 pole remotely operated
More informationTMC 91H is now TMC 60 C Series
TMC 91H is now TMC 60 C Series The new Thermal Magnetic Circuit Breaker is once again available and better than ever! The new version is not only UL recognized with the same electrical performance as the
More informationK30H001YP cam star-delta switch - 3-pole A - screw mounting
Characteristics cam star-delta switch - 3-pole - 60-32 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing
More informationIEC fuse holders & fuse disconnectors: CMS 14
Modulostar CMS14, CMS22 Modulostar IEC fuse holders & fuse disconnectors: CMS 14 IEC fuse holders: CMS 14: Fuse holder compliant with IEC 60269-1 & 2, and tested in accordance with IEC 60947-1 & 3 for
More informationSystem pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489
System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489 2CDC021004S0014 2CDC021046S0014 The miniature circuit breaker SU 200 M is ABB s solution for UL 489 branch
More informationGeneral Purpose Relay
General Purpose Relay KML 15A switching capability 1.5kV dielectric strength (between coil and contacts) Various terminals available Socket available 1 to 3 pole configurations 1. COIL DATA (at 23 ) 1)
More informationPSC Protection Semiconductor Square Body Fuses Now manufactured in North America for faster delivery to our North American consumers SOLUTIONS GUIDE
PSC Protection Semiconductor Square Fuses Now manufactured in North America for faster delivery to our North American consumers SOLUTIONS GUIDE PSC Square Fuses: Built with speed in mind Mersen s high-performance
More informationRSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX
IEC-Contactor RSC 1 Features Rated operational current 9 63 (C-3) Coil voltages C 24, 230V 3 main contacts and auxiliary contact Extendable with auxiliary contact block Mounting position any 2 Description
More informationDX³ 4-pole RCBO 6000 A/10 ka
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ 4-pole RCBO CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More informationContactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660
Characteristics Environment Rated insulation voltage (Ui) Conforming to IEC/EN 60947-1, V 690 IEC/EN 60947-4-1, VDE 0110 gr C, CSA - n 14, UL 508.1 Conforming to standards IEC/EN 60947-1, IEC/EN 60947-4-1,
More informationSafety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries
Safety Relay Unit Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries Two-pole slim models that are only 22.5 mm wide, three-pole models that are only 68 mm wide,
More informationData sheet. CI-tronic Soft start motor controller Type MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 50 I-O 520B1443
CI-tronic Soft start motor controller Type MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 50 I-O December 2002 DKACT.PD.C50.G2.02 520B1443 2 DKACT.PD.C50.G2.02 Danfoss A/S 12-2002 Introduction The MCI soft starters
More informationVarius SUMMARY OF MODELS
Varius SUMMARY OF MODELS Type FH00 FH1 FH2 FH3 LTL4a Rated operating current I e 160 A 160 A 250 A 400 A 630 A 1 600 A Rated operating voltage AC/DC U e 690 V 690 V 690 V 690 V 690 V 690 V Size 000 00
More informationDX³ RCBO 6000 A Phase + Neutral, neutral right side
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX³ RCBO 6000 A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection... 1
More informationThermal-Magnetic Circuit Breaker M1-..
Thermal-Magnetic Circuit Breaker 30-...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic
More informationDesign Guide. VLT Soft Start Controller MCD 100
Design Guide VLT Soft Start Controller MCD 100 Introduction The MCD 100 soft starters are designed for soft starting and stopping of 3 phase a.c. motors, thus reducing the inrush current and eliminating
More informationCylindrical fuse-link
ylindrical fuse-link Technical data Rated voltage Rated current Rated frequency Rated breaking capacity haracteristics Body material 00 V A, 500 V A, 90 V A H 8-5 A/00 V H 0,5- A/500 V, 0-3 A/00 V H -5
More informationDRX 100 B/N/H Circuit breaker (not adjustable)
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (continuation) 2 4. MOUNTING 2 5. CABLING 3 6. ELECTRIC AND MECHANICAL
More informationT2111EN Technical Data Sheet Rev 04 Air Cooled Rectifier Bridge MVR : 690V, 1600Adc
GE Power Conversion MVR1600-4601: 690V, 1600Adc FEATURES/SPECIFICATIONS Rated at 690 Vac, 1600 Adc (nominal). Thyristor/Diode based Rectifier Bridge Module. Air Cooled. Protected Pre-charge circuit. RELATED
More informationLimit switches. 7 Page 71. Presentation. OsiSense XC Basic Compact design, plastic, with reset knob, types XCNR and XCNTR. b XCNR.
Presentation Compact design, plastic, with reset knob, types XCNR and XCNTR b XCNR with cable entry v With head for linear movement (plunger) Page v With head for rotary movement (lever) Page b XCNTR with
More informationProtistor size 70 gr 690VAC (IEC)
Protistor size 70 gr SEMICONDUCTOR PROTECTION FUSES SQUARE BODY HIGH-SPEED FUSE-LINKS AC PROTECTION FEATURES & BENEFITS Excellent cycling capability Multiple body sizes and terminals or blades combination
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker
Magnetic and Hydraulic-Magnetic Circuit Breaker 835-... Description Single or multipole hydraulic-magnetic circuit breakers with trip-free - mechanism and toggle actuation. A choice of switching characteristics
More informationAF40... AF96 3-pole contactors Technical data
Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional
More informationThermal Overcurrent Circuit Breaker 3120-F...
Thermal Overcurrent Circuit Breaker -F... Description An extremely versatile range of rocker switch/thermal circuit breakers (S-type TO CBE to EN 694 with trip free mechanism) offering the choice of single
More informationfuses fuse holders CYLINDRICAL
fuses fuse holders 02 gg FUSES 04 am FUSES FUSES 09 PMC COMPACT 09 -CC FOR CC CLASS FUSE-LINKS 11 PMB PLUG CONNECTION 11 CLIP CONTACT FOR φ10 FUSE-LINKS 10 PMF 11 BAC OPEN FUSE BASES 06 gg FUSES FUSES
More informationVB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated
VB6, VB7 -pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated VB7-0-10 2CDC211006F0011 Description VB6, VB7 -pole compact design reversing contactors are space optimized control
More informationFuse switch-disconnectors
Fuse switch-disconnector FH00 is intended fuse-links with blade contacts size 000 and 00. It enables safe disconnection not only of rated current, but also overcurrent up to octuple rated current. A version
More informationup to 63 A (1 module per pole)
87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Direct current MCB DX 3 16kA, up to 63 A (1 module per pole) CONTENTS PAGE 1. Description - Use... 1 2. Range... 1 3. Overall dimensions...
More informationControl switch/load disconnect switch Series 8008
> s Control switch with 2, 3 or 4 pole Load switch 3 pole + 1 auxiliary contact > Rated operational voltage up to 690 V AC > Positive opening contacts > Contacts suitable for EM-STOP > Isolating characteristics
More informationCI-Tronic Soft start motor controller MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 40-3D and MCI 50-3 I-O
Data sheet CI-Tronic Soft start motor controller MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 40-3D and MCI 50-3 I-O The MCI soft starters are designed for soft starting and stopping of 3 phase AC motors, thus
More informationDX³ RCBO 6000A Phase + Neutral, neutral on left
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ RCBO 6000A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection...
More informationPage 12-2 Page Page Page DC FUSES FOR PHOTOVOLTAIC APPLICATIONS 10x38mm, IEC class gpv Rated current: 20A Rated voltage: 1000VDC.
Page -2 Page -2 AC FUSE HOLDERS Version without indicator: 1P, 1P+N, 2P, 3P, 3P+N Version with indicator: 1P For fuses x38, 14x51 and 22x58mm IEC class gg or am. IEC rated current: 32A, 50A, 0A IEC rated
More informationNon-Fused Load Break Switches FSSC, SX, SXDC, SC
Non-Fused Load Break Switches FSSC, SX, SXDC, SC UL 98 Non-Fused Load Break Switches Mersen disconnect switches are extremely durable, manually operated, non-fused disconnect switches. These heavy-duty
More informationFUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A
Fuse protection The solution for > Motor load break > Protection of industrial cabinet > Electrical distribution fusom_063_b_1_cat Strong points > Tripping upon overload > High breaking capacity > Improved
More informationThe breakers offer thermal-magnetic trip protection according to Z and K characteristics.
Series High Performance Circuit Breakers Description The high performance MCB offers a compact solution to circuit protection. The devices are DIN rail mounted. The is available with application-specific
More informationSystem pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077
Data Sheet System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077 2CDC021026S0011 2CDC021016S0012 The S 200 PR is a high-performance supplementary protector with
More information