1 Parts dentification Description Notes Table of Contents Page This Price List contains descriptions and style numbers for VCP-W breakers including 5, 7.5, 15, and 27 kv VCP-W, VCPW-ND, VCPW-SE, and the VCP-WR family of breakers. Additional information and illustrations are shown in Section 7 of B (VCP-W, VCPW-ND, VCPW-SE), and Section 8 of B 8295A61H01 (VCP-WR). The style numbers listed are for ANS-rated breakers only. Ordering nformation 1. Description and style number. 2. Quantity. 3. Enter all orders on VSTA Order Entry Suffix Parts are identified by Breaker Type in the top row and Part Description in the left column. 2. nterrupter Assemblies are described by voltage class and rat ing. Example: 50/250, 1200A-58 ka where 50 = voltage class of 5 kv 250 = MVA rating 1200A =continuous current rating 58 ka = Close and latch rating (rms) 3. Unique parts for 27 kv and VCPW-ND have been identified. Where a 27 kv common part is needed, select the VCPW-SE style. Where VCPW-ND common part is needed, select the VCP-W style for this component. nterrupter Assembly... 2 Primary Disconnect... 3 Phase Barriers... 3 Trip D-Shaft Trip Latch (Hatchet)... 4 Push Rod Assembly... 4 Tie Bar Shock Absorber... 4 Charging Motor... 4 Motor Brush Kit... 4 Spring Release (Close) Coil Second Shunt Trip Kit... 5 Shunt Trip Coil Undervoltage Trip Kit Undervoltage Trip Coil Anti-Pump Relay... :... 5 Motor Cut Off Switch... 6 Latch Check Switch Position Switch Auxiliary Switch Ground Contact Assembly... 6 Front Panel (wit hout Eschuteon)... 6 Breaker Wheel... 7 Fastener Kit Labels Kit... 7 Recommended Spare Parts... 8 TypeVCP-W Type VCPW-ND Type VCPW-SE Product Code 6071 Discount Symbol Y1

2 Page 2 nterrupter Assembly Description VCPW-ND 50/250, 1200A-58 ka Ordering nformation 8297A02H03 $1,987 VCP-W, VCPW-ND, VCPW-SE, VCP-29WR, VCP-29WRSE 1200A, 2000A 50/250, 1200A-58 ka 8297A02H A02H02 3A73901H01 3A73919H01 3A73923H01 50/250H, 1200A-78 ka 8297A05H A05H02 50/250, 2000A-58 ka 8297A03H A03H02 3A73902H01 3A73920H01 3A73924H01 50/250H, 2000A-78 ka 8297A06H A06H02 50/250, 3000A-58 ka 8297A04H A04H02 3A73903H01 50/250H, 3000A-78 ka 8297A07H A07H02 1,987 2,515 2,705 2,927 3,888 4,199 VCP-W, VCPW-SE, VCP-29WR, VCP-29WRSE 3000A 50/350, 1200A-78 ka 8297A08H A08H02 (7 in. V..) 50/350, 1200A-78 ka 8297A08H A08H04 3A73904H01 3A73921H01 3A73932H01 (5 in. V..) 50/350, 2000A-78 ka 8297A09H A09H02 (7 in. V..) 50/350, 2000A-78 ka 8297A09H A09H04 3A73905H01 3A73922H01 3A73933H01 (5 in. V..) 50/350, 3000A-78 ka 8297A10H A10H02 3A73906H01 75/500, 1200A-66 ka 8297A11H A11H02 (5 in. V..) 75/500, 1200A-66 ka 8297A11H A11H04 3A73907H01 3A73907H02 3A73925H01 (4 in. V..) 75/500, 2000A-66 ka 8297A12H A12H02 3A73908H01 3A73908H02 3A73926H01 75/500, 3000A-66 ka 8297A13H A13H02 3A73909H01 3A73909H02 2,552 2,552 3,186 3,186 5,209 2,809 2,809 3,352 5,126 VCP-20WR 150/500, 600A-37 ka 3A73927H01 150/500, 1200A-37 ka 8297A17H A17H02 3A73910H01 3A73910H02 3A73928H01 150/SOOH, 1200A-58 ka 8297A20H A20H02 150/500, 2000A-37 ka 8297A18H A18H02 3A73911H01 3A73911H02 3A73929H01 150/SOOH, 2000A-58 ka 8297A21H A21H02 150/500, 3000A-37 ka 8297A19H A19H02 3A73912H01 3A73912H02 150/SOOH, 3000A-58 ka 8297A22H A22H02 2, 2,286 3,136 2,953 3,539 4,499 4,907 15on5o, 1200A-58 ka 8297A23H A23H02 3A73913H01 3A73913H02 3A73930H01 15on50H. 1200A-77 ka 8297A26H A26H02 15on5o, 2000A-ss ka 8297A24H A24H02 3A73914H01 3A73914H02 3A73931H01 15onsoH. 2000A-77 ka 8297A27H A27H02 15on5o, 3000A-58 ka 8297A25H A25H02 3A73915H01 3A73915H02 15onsoH. 3000A-77 ka 8297A28H A28H02 3,416 3,723 4,278 4,506 5,580 6,513 VCP-18WR 150/1000, 1200A-77 ka 8297A29H A29H02 (7 in. V.1.) 150/1000, 1200A-77 ka 8297A29H A29H04 3A73916H01 3A73916H02 (5 in. V..) Quantity (3) interrupter assemblies are required per breaker. The style and list price represents quantity (1) interrupter assembly. Vacuum interrupter (V.) assemblies have both 5-inch and 7-inch or 5-inch and 4-inch vacuum interrupters. These are identified by either (4 in. V..}, (5 in. V.l.J, or (7in. V..) at the end of the description. When ordering match the V.. diameter and corresponding rating. 4,809 4,809 )

3 Page 3... ""' nterrupter Assembly, continued,,.,....,.....!.i r..r 150/1000, 2000A-77 ka 8297A30H A30H02 $5,974 (7 in. V..) 1~1000, 2000A-n ka 8297A30H A30H04 3A73917H01 3A73917H02 5,974 (5 in. V..) 150/1000, 3000A-77 ka 8297A31H A31H02 3A73918H01 3A73918H02 6, /25, 630A-40 ka 8299A04H01 4, /25, 1200A-40 ka 8299A05H01 4, /25, 2000A-40 ka 8299A02H01 6,199 27kVVCP-W Primary f ,:,.-... VCPW-ND 5 kv, 1200A 502A851G12 $275 Up to 15 kv, 1200A 508B022G01 508B022G Up to 15 kv, 2000A 508B012G01 508B012G Up to 15 kv, 3000A 692C037G01 692C037G kv, 630A 699B352G kv, 1200A 699B352G kv, 2000A 502A852G ;r 1200A and 2000A All 3000A, All 27kV, and VCPW-ND Phase Barriers Descriptio n Ordering nformation VCPW-ND 5 kv@ 8829C40H01 s 85 Up to 15 kv@ 691C176H04 691C176H04 691C176H04 691C176H04 690C846H B34H01 85 All , 150/1000 & 3000A (7'' V..) 691C648G01 691C648G01 691C648G01 691C648G kv~ 691C218H /350, 150/ A and 2000A (5" V..) 691C176H04 691C176H04 85 All 27kV and A ll All 50/350, Breakers Up to 150/ 1000 (7" V.1.), 15kV and all 3000A Trip D-Shaft,,.,, 1m ~ 1...,. ~ l lf L.. -!.i.. r o.r VCP-29WRSEVCP-20WR VCP-18WR l694c638g01 694C638G01 l 694C638G01 l 694C638G01 l694c638g C638G01 Quantity (3) interrupter assemblies are required per breaker. The style and list price represents quantity ( 1) interrupter assembly. ~ Vacuum interrupter (V.) assemblies have both 5-inch and 7-inch or 5-inch and 4-inch vacuum interrupters. These are identified by either (4 in. V.l.J, (5 in. V.l.J, or (7in. V.l.J at the end of the description. When ordering match the V.. diameter and corresponding rating. ~ A phase barrier style represents a quanf;ty of (1) barrier per style. VCP-W breakers may require 2 or 4 barriers per breaker (Reference 18 Quantity (6) primary disconnects are required per breaker. Style numbers listed above represent quantity (1) primary disconnect. $498

4 Page 4 Trip Latch (Hatchet) t.j.:+."l. Hlll U 1:.. - f l,...,... VCP-29WRSEVCP-20WR VCP-18WR Breakers Shipped 1699B040G02 699B040G02 699B040G02 699B040G G02 699B040G02 $141 before June '94 Breakers Shipped 699B040G03 699B040G03 699B040G03 699B040G03 699B040G03 699B040G after June '94 A ll Breakers -m=t:~~~:j~~-~n {][]J==El'l--1 Spade Terminals for VCP-W ([B s Ring Terminals for ' VCPW-SE, VCP-29WR, 29WRSE, 20WR, 1 SWR \\\\\\\\\\ ~ All Motors Push Rod Assembly D escription Ordering nformation VCPW-ND 5 kv (blue) 692C799G01 $250 Up to 5 kv (blue) 692C799G01 690C854G Up to 5 kv (red) 692C799G02 690C854G Up to 15 kv (white) 691C650G01 691C650G C650G02 691C650G Up to 15 kv (blue) 691C651G01 691C651G C651G02 691C651G Up to 15 kv (red) 691C651G03 691C651G C651G04 691C651G kv (blue) 691C241G lie Bar 1 l1 t o1 r;1 l L... -!..r.jral". Up to 5 kv 690C818H01 $ Upto15 kv 3619A09H A09H01 ) 691C271H01 691C271H k.v 691C223H Up to 15 kv, Lower Support (350, 1000 MVA; 1200,2000A) Shock Absorber Description... Charging Motor..... l 5697B19H01 686C575H B19H01 686C575H B26H B26H B26H H B26H01 $160 lt.!..1 11u ~ 11. ~:i VCP-W VCPW-5E VCP-29WR VCP-29WRSE VCP-20WR VCP-18WR 699B196G03 699B196G06 699B196G06 699B196G06 699B196G06 699B196G06 $625 Vdc / 120 Vac 699B196G01 699B196G04 699B196G04 699B196G04 699B196G04 699B196G Vdc / 240 Vac 699B196G GOS 699B196G05 699B196G G05 699B196G Motor Brush Kit 18063A77G A77G01 l 8063A77G01 l 8063A77G01 l8063a77g01 l8063a77g01 S55 The VCP-18WR Push Rod Assembly is included wirh the Pole Unit Replacement. Januar y 16, 1996

5 Page 5 Spring Release (Close) Coil Description Ordering nformation 3759A76G A76G A76G11 Vdc / 120 Vac 3759A76G A76G A76G Vdc / 240 Vac 3759A76G A76G A76G13 Rectifier (120/240 Vac) 3759A79G A79G A79G02 VCP-29WRSE VCP-20WR VCP-18VVR 3759A76G A76G A76G A76G A76G A76G A76G A76G A76G A79G A79G A79G02 $ 160 Spade Terminals for VCP-W and VCPW-ND Second Shunt Trip Kit Description Ordering nformation 24 Vdc 694C636G C84G C84G14 694C636G C84G C84G11 Vdc 694C636G C84G C84G Vdc 694C636G C84G C84G13 Shunt Trip Coil VCP-29WRSE VCP-20WR VCP-18WR 8794C84G C84G C84G C84G C84G C84G C84G C84G C84G C84G C84G C84G03 S Ring Terminals for VCPW-SE, VCP-29WR, 29WRSE, 20WR, 18WR Spade Terminals for VCP-W and VCPW-ND om = J Ring Terminals for All Other Breakers Description 'Ordering nformation 24 Vdc 3759A76G A76G A76G A76G A76G A76G11 Vdc / Vac CAP 3759A76G A76G A76G Vdc / 240 Vac CAP 3759A76G A76G A76G13 VCP-29WRSE VCP-20WR VCP-18VVR 3759A76G A76G A76G A76G A76G A76G A76G A76G A76G A76G A76G A76G13 $ Spade Terminals for VCP-W and VCPW-ND UV Trip Kit Ring Terminals for VCPW-SE, VCP-29WR, 29WRSE, 20WR., 18WR Description Ordering nformation 691C274G01 691C274G C81G01 Vdc 691C274G02 691C274G C81G Vdc 691C274G03 691C274G C81G Vac 691C274G04 691C274G C81G Vac 691C274G05 691C274G C81G05 VCP-29WRSE VCP-20WR VCP-18WR 8794C81G C81G C81G C81G C81G C81G C81G C81G C81G C81G C81G C81G C81G C81G C81G05 $1,188 1,188 1,188 1, (Rectifier is i ncluded for AC Voltages Only) UV Trip Coil D escription Ordering nformation 8064A19G A19G A19G01 Vdc 8064A19G A19G A19G Vdc 8064A19G A19G A19G Vac 8064A19G A19G A19G Vac 8064A19G A19G A19G08.. Anti-Pump (Y Relay ~ , t:1 1 j 3759A74G A27H A27H03 Vdc 3759A74G A27H A27H04 250Vdc 3759A74G A27H A27H Vac 3759A74G A27H A27H Vac 3759A74G A27H A27H02 A rectifier is required for AC Closed Circuits Only. VCP-29WRSE VCP-20WR VCP-18VVR 8064A19G A19G A19G A19G A19G A19G A19G A19G A19G A19G A19G A19G A19G A19G A19G08 VCP-29WRSE VCP-20WR VCP-18VVR 8237A27H A27H A27H A27H A27H A27H A27H A27H A27H A27H A27H A27H A27H A27H A27H02 $ $ Ring Terminals Ring CY All 27 kv, VCP 29WR, 29WRSE, 20WR, 18WR, and VCPW-SE Spade OJ VCP-Wand VCPW-ND

6 Page 6 Motor Cut Off Switch...:r...1."ll... lue -...,, o11111:... r.1:.: VCP-W VCPN-SE VCP-29WR jvcp-29wrsevcp-20wr VCP-18WR 1699B199G01 699B199G04 l 699B199G B199G04 l699b199g B02G04 $300 VCP W, VCPW-SE, VCP 29WR, 29WRSE, 20WR VCP 18WR Latch Check Switch 1~ 1.. Ufll lu:1 -..,....!VCP-W VCPN-SE VCP-29WR VCP-29WRSEVCP-20WR VCP-18WR 699B147G01 699B147H04 699B147H04 699B147H B147H04 l699b147h04 $180 Position Switch (PS1 ) 1..,_:.r..._"ll VCP-W VCPN-SE VCP-29WR VCP-29WRSEVCP-20WR VCP-18WR l8064a03g B147H01 699B147H01 j 699B147H01 l699b147h B1 47H01 $165 Position Switch (PS2l 1,"11nu1 l1 f Hl 11 1,.,.. 1.-i:t ~- VCP-W VCPN-SE VCP-29WR VCP-29WRSE VCP-20WR VCP-18WR j3759a93g A93H A93H A93H A93H A93H02 $165 '. ) Spade Terminals for VCP-W Auxiliary Switch ll.._ ;..."'... n1u f J ( - 11 r "'.. VCP-W,VCPN.sf. VCP-29WR VCP-29WRSE VCP-20WR VCP-18WR ~8B~22H B02G B02G B02G B02G B02G01 $230 VCPW-ND 5697B02G02 r 230 Ring Terminals for VCPW-SE, VCP-29WR, 29WRSE, 20WR, 18WR, VCPW-ND H VCP-W, VCPW-SE and VCPW-ND Ground Contact Assembly D escription Ordering nformation VCP-W VCPN-SE VCP-29WR VCP-29WRSE VCP-20WR VCP-18WR 691C506G01 691C506G01 $100 VCPW-ND 691C506G Front Panel (without Eschuteon) ll1:.1:1... 1u1u... -,... 1 VCP-W VCPN-SE VCP-29WR VCP-29WRSE VCP-20WR VCP-18WR VCPW-ND 8829C48H01 $ A, 350 & 1000 MVA 691C655H01 691C655H01 691C655H01 691C655H C70H kv 691C214H All Others -691C192H02 691C192H02 691C192H02 691C192H H , L._... ft..t

7 Page 7 Breaker Wheel Description Ordering nformation VCP-29WRSE VCP-20WR VCP-1 8WR VCPW-ND 8237A50H01 $ All Others 3617A99H A99H02 Fastener Kit "-1._~.., l1u. Labels Kit... VCP-W Jlll11r. 111 ST;;;i;-~. WCP-W VCPW-SE VCP-29WR. VCP-29WRSEVCP-20WR lvcp-18wr l8061a01g A01G01 l 8061A01G01 l 8061A01G01 l 8061A01G01 j8061a01g01 $50 ~~~ VCPW-SE VCP-29WR VCP-29WRSEVCP-20WR VCP-18WR B295A45G01 J8295A45G01 B295A45G01 J8295A45G01 J8295A45G01 J8295A45G01 $45 ~~~&,. Discharged 1 Charged. l.. VCP- WR Series 29 VCP WR Series 20 VCP-WR Series 18

8 Page 8 ( ) Medium Voltage Product Literature SA SA 11671AR SA B B 8295A61 H01 RPO AD VacClad-W Switchgear VacClad-W Arc Resistant Switchgear VCP-W World Class Switchgear VCP-W Breaker nstruction Manual VCP-WR Breaker nstruction Manual VacClad-W Breaker and Switchgear Renewal Parts Data VacClad-W Application Data Recommended Spare Parts for Stock An adequate stock of spare parts will help minimize emergency situations and can substantially reduce production downtime. The quantities listed are recommended for 5 breakers of the same rating. Please include complete style numbers, as required for your application, and forward all inquires to your local sales representative. tem Recommended Description Ouantitv for Stock 1 3 nterrupter Assembly 2 6 Primary Disconnect 3 3 Push Rod Assembly 4 1 Charging Motor 5 1 Motor Brush Kit '" 6 1. Sorina Release (Close) Coil 7 1 Shunt Trip Coil 8 1 Anti-Pump Relay 9 1 Fastener Kit Labels Kit Select per Breaker Rating or Control Ratings. Style Number 8063A77G A01G A45G01 Complete Factory and ANS Design Testing All VCP-W Vacuum Circuit Breakers meet or exceed applicable ANS standards. Tests include: mechanical endurance, power interruption, momentary current, and BL. Certification to the applicable design tests are available from Cutler Hammer upon request. Certified factory production test reports are also available. Warranty VCP-W Vacuum Circuit Breakers and genuine VCP-W renewal parts are covered under the standard Cutler-Hammer warranty. Contact Cutler-Hammer for details. Notice for Commercial Grade Components THE DESCRPTON AND SPECFCATONS FOR THE PRODUCTS DESCRBED HEREN ARE PROVDED FOR GENERAL COMMERCAL USE AND NOT APPLCA- (. J BLE FOR USE N A NUCLEAR POWER PLANT. ADDTONAL CERTFCATON MAY BE AVALABLE UPON REQUEST TO QUALFY THESE PRODUCTS FOR USE N SAFETY-RELATED APPLCATONS N A NUCLEAR FACLTY. Cutler-Hammer Westinghouse & Cutler-Hammer Products Five Parkway Center Pittsllurgh, Pennsylvania, U.S.A ( Printed in U.S.A.

www. ElectricalPartManuals. com It'll Cutler-Hammer WLI Medium Voltage Switchgear Renewal Parts Renewal Parts Data Page 1

www. ElectricalPartManuals. com It'll Cutler-Hammer WLI Medium Voltage Switchgear Renewal Parts Renewal Parts Data Page 1 t'll Cutler-Hammer Supersedes Renewal Parts Data, pages 1-2, dated June 1992 Renewal Parts Data Page 1 WL Medium Voltage Switchgear Renewal Parts Renewal Parts Data Page 2 WL Medium Voltage Switchgear

More information

WLI Medium Voltage Switchgear Renewal Parts

WLI Medium Voltage Switchgear Renewal Parts Page 1 Supersedes Renewal Parts Data, pages 1-2, dated June 1992, WLI Medium Voltage Switchgear Renewal Parts Page 2 Standard Manually Operated Fused WLI Switch ➇ ➁ ➀ ➂➃ WLI Switch Mechanism ➉ ➈ m Replacement

More information

Page 2 DS LOW VOLTAGE POWER CIRCUIT BREAKERS Digitrip Trip Unit Inside Wiring Guide Outside Wiring Guide Shutter Drawout Unit Position Indicator Escut

Page 2 DS LOW VOLTAGE POWER CIRCUIT BREAKERS Digitrip Trip Unit Inside Wiring Guide Outside Wiring Guide Shutter Drawout Unit Position Indicator Escut Page 1 Supersedes Renewal Parts Data 33-790-1G pages 1-20 dated December, 1988 Mailed to: C, D, E/33-700 Westinghouse DS and DSL Low Voltage Power Circuit Breakers and Cell Parts Contents Pages DS Breaker

More information

Instruction Bulletin. DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Class 6035

Instruction Bulletin. DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Class 6035 Instruction Bulletin 4402-997-0 February 999 Middletown, OH, USA DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Class 605 DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker

More information

FOR PRICES ON DSII and DSLII BREAKERS, REFER TO PRICE LIST PL.22B.01.P.E

FOR PRICES ON DSII and DSLII BREAKERS, REFER TO PRICE LIST PL.22B.01.P.E Supersedes PL.44B.04.P.E Dated September 1998 600 Volts AC Maximum 200 ka, RMS Sym. Short Circuit Maximum 800-5000 Amps Continuous Effective: October 1999 Page 1 Index Page Table Description/Application...

More information

Using new Magnetically Actuated Vacuum Interrupter technology for safe and reliable medium voltage circuit breaker switching in mines

Using new Magnetically Actuated Vacuum Interrupter technology for safe and reliable medium voltage circuit breaker switching in mines Using new Magnetically Actuated Vacuum Interrupter technology for safe and reliable medium voltage circuit breaker switching in mines Abstract: The development of the magnetically actuated vacuum interrupter

More information

Table Types LD, HLD and LDC Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units

Table Types LD, HLD and LDC Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units -1 1 Amperes July 07 Product Selection Table -191. s, H and C Thermal-Magnetic Circuit s with Interchangeable Trip Units Maximum Continuous Ampere at 40 C 2-Pole 0 0 3-Pole 0 0 4-Pole 0 0 Magnetic trip

More information

Medium Voltage Metal-Enclosed Switches

Medium Voltage Metal-Enclosed Switches Medium Voltage Metal-Enclosed Switches Outdoor Medium Voltage Switch.1 Medium Voltage Switch MVS Product Description............................................. 2 Application Description..........................................

More information

Table Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English.

Table Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English. -174 Series C Molded Case Circuit s July 7 Molded Case Switches Refer to Eaton for UL listed, series tested Molded Case Switch application data. Table -278. Molded Case Switches Cont. Amp Rating at 40

More information

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents January 2003 Vol. 1, Ref. No. [1011] -1 Medium Voltage Metal-Enclosed Switches Contents Description Page MVS................................... -2 and Breaker MSB........................ -3 Metal-Enclosed

More information

www. ElectricalPartManuals. com Cutler-Hammer Power Breaker Center Renewal Parts for Low Voltage Power Circuit Breakers Types DB, DBL and DBF

www. ElectricalPartManuals. com Cutler-Hammer Power Breaker Center Renewal Parts for Low Voltage Power Circuit Breakers Types DB, DBL and DBF New Information Control Relay Auxiliary Switch Operating Mechanism CutlerHammer Power Center 10 Maxwell Avenue Greenwood, SC 29646 1877276979 Closing Solenoid 2254 Renewal Parts for Low Voltage Power Circuit

More information

1VAL2401-SG Rev D. Spare parts list for Outdoor Products Reclosers, breakers, & padmount switches

1VAL2401-SG Rev D. Spare parts list for Outdoor Products Reclosers, breakers, & padmount switches 1VAL2401-SG Rev D Spare parts list for Outdoor Products Reclosers, breakers, & padmount switches Reclosers GridShield recloser 12A00736H05 Actuator assist capacitor Single-phase upgrade 15 KV, 800 A, 12.5

More information

Medium Voltage Metal-Enclosed Switches

Medium Voltage Metal-Enclosed Switches Medium Voltage Metal-Enclosed Switches Outdoor Medium Voltage Switch.1 Introduction Product Selection Guide....................................2 Medium Voltage Switch MVS Product Description......................................

More information

VacClad-W type VCP-W 5 and 15 kv, 36-inch-wide switchgear components

VacClad-W type VCP-W 5 and 15 kv, 36-inch-wide switchgear components Supersedes July 2002 Contents Page Procedure for identifying parts... 2 Customer ordering instructions.... 2 Distributor ordering instructions.... 2 Front panel components.... 3 Breaker pan assembly....

More information

PoweMr' With 18 Mechanism '. 1 . / ,, ( c :11t

PoweMr' With 18 Mechanism '. 1 . / ,, ( c :11t ) rvac Vacuu m Circuit. Breaker PoweMr' With 8 Mechanism L- '.. /,, ( (' p c :t ) FRONT VIEW,. 0 3 Fig. Front View of Breaker with Front Cover 3. COUNTER 0. INTERRUPTER ASSEMBLY Fig. 2 Front View of Breaker

More information

L-Frame LD F. Circuit Breaker/ Frame Ampere Rating. Trip Unit Rating/ Plug Ampere Rating LD T5 7 W

L-Frame LD F. Circuit Breaker/ Frame Ampere Rating. Trip Unit Rating/ Plug Ampere Rating LD T5 7 W July 07 5 Amperes -111 Product Selection This information is presented only as an aid to understanding catalog numbers. It is not to be used to build catalog numbers for circuit breakers or trip units.

More information

Instructions for Installation, Operation and Maintenance of Type VCP-W Vacuum Circuit Breakers IB131006EN

Instructions for Installation, Operation and Maintenance of Type VCP-W Vacuum Circuit Breakers IB131006EN Instructions for Installation, Operation and Maintenance of Type VCP-W Vacuum Circuit Breakers IB006EN IB006EN Page iii WARNING WARNING IMPROPERLY INSTALLING OR MAINTAINING THESE PRODUCTS CAN RESULT IN

More information

VCP-T/T-VAC medium voltage vacuum circuit breakers. Control and protect with Eaton s compact medium voltage circuit breakers

VCP-T/T-VAC medium voltage vacuum circuit breakers. Control and protect with Eaton s compact medium voltage circuit breakers VCP-T/T-VAC medium voltage vacuum circuit breakers Control protect with Eaton s compact medium voltage circuit breakers Eaton Corporation has dedicated years of research, design testing to create a comprehensive

More information

Motor Control. Motor Control Electrical Aftermarket Products and Services Contents

Motor Control. Motor Control Electrical Aftermarket Products and Services Contents June 00 Aftermarket Solutions, Ref. No. [] - CA0000E Contents Description Page Contactors, Starters & Brakes................................... - Product Description.........................................

More information

T- VACR Fixed (up to 40kA) T-VAC Draw out (up to 40kA)

T- VACR Fixed (up to 40kA) T-VAC Draw out (up to 40kA) Instructions for the Use, Operation and Maintenance of Types T-VAC and T-VACR Vacuum Circuit Breakers Effective November 2017 T- VACR Fixed (up to 25kA) T-VAC Draw out (up to 25kA) T- VACR Fixed (up to

More information

Instructions for Installation, Operation and Maintenance of Type VCP-W Vacuum Circuit Breakers IB131006EN

Instructions for Installation, Operation and Maintenance of Type VCP-W Vacuum Circuit Breakers IB131006EN Instructions for Installation, Operation and Maintenance of Type VCP-W Vacuum Circuit Breakers IB006EN IB006EN Page iii WARNING WARNING IMPROPERLY INSTALLING OR MAINTAINING THESE PRODUCTS CAN RESULT IN

More information

Cutler-Hammer I.B F. Instructions for Installation, Operation and Maintenance of Type VCP-W Vacuum Circuit Breakers

Cutler-Hammer I.B F. Instructions for Installation, Operation and Maintenance of Type VCP-W Vacuum Circuit Breakers Cutler-Hammer I.B. 32-255-1F Instructions for Installation, Operation and Maintenance of Type VCP-W Vacuum Circuit Breakers Supersedes I.B. 32-255-1E dated July, 1997 I.B. 32-255-1F Page iii WARNING WARNING

More information

Publication No.: PSG

Publication No.: PSG TABLE OF CONTENTS PAGE 1.0 SCOPE...2 2.0 STANDARDS...2 3.0 DESIGN REQUIREMENTS...2 3.01 Service Conditions... 2 3.02 Ratings... 3 3.03 Resistors... 3 3.04 Interrupter... 4 3.05 SF 6 Gas System... 4 3.06

More information

Miniature Circuit Breakers

Miniature Circuit Breakers S00 Series Miniature S00 Series Miniature Circuit Breakers Description The S00 Series miniature circuit breaker offers a compact solution for protection requirements. The S00 devices are UL tested limiting

More information

Amperes. F-Frame. Price U.S. $ Catalog Number. Price U.S. $ EDH2100 EDH2125 EDH2150 EDH2175 EDH2200 EDH2225

Amperes. F-Frame. Price U.S. $ Catalog Number. Price U.S. $ EDH2100 EDH2125 EDH2150 EDH2175 EDH2200 EDH2225 January 1 Vol. 1, Ref. No. [0487] 2 Amperes - Product Selection Table -33. s,, and E Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units Suitable for Reverse Feed Maximum Continuous Ampere

More information

GEF Renewal Pans. low Vohage Power Circuit Breakers. Type AKR-30S and AKRU-30S. www. ElectricalPartManuals. com

GEF Renewal Pans. low Vohage Power Circuit Breakers. Type AKR-30S and AKRU-30S. www. ElectricalPartManuals. com -- GEF-6005 Renewal Pans low Vohage Power Circuit Breakers Type AKR-30S and AKRU-30S INTRODUCTION This manual provides a listing of the parts and assemblies that are availle as replacement parts for low

More information

Frame Sizes: AKJ/ AKJT I AKJU-50 and AKR/ AKRU-30/ 50, AKRT-50

Frame Sizes: AKJ/ AKJT I AKJU-50 and AKR/ AKRU-30/ 50, AKRT-50 RENEWAL PARTS LOW VOLTAGE POWER CIRCUIT BREAKERS Frame Sizes: AKJ/ AKJT I AKJU-50 and AKR/ AKRU-30/ 50, AKRT-50 GEF-4527F Supersedes GEF-4527E TABLE A. INDEX OF BREAKER MODELS COVERED BY THIS PUBLICATION

More information

W-VACi IEC medium voltage vacuum circuit breakers 12 kv, 17,5 kv and 24 kv

W-VACi IEC medium voltage vacuum circuit breakers 12 kv, 17,5 kv and 24 kv This is a photographic template your photograph should fit precisely within this rectangle. W-VACi IEC medium voltage vacuum circuit breakers 12 kv, 17,5 kv and 24 kv Mostapha Azzahimi Product Manager

More information

Product Line Overview. The Most Logically Designed Contact Assembly

Product Line Overview. The Most Logically Designed Contact Assembly Circuit Breakers & Supplementary Protectors 15 00 Amperes for UL, CSA & IEC Applications Product Line Overview -3 General Information Cutler-Hammer Series G Molded Case Circuit Breakers provide increased

More information

Table Type FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units

Table Type FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units -22 2 Amperes January 1 Vol. 1, Ref. No. [0488] Table -. FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units Max. Cont. Ampere Rating @ 40 C 600V AC Maximum, 0V DC 277V AC Maximum,

More information

ABB. Replacement Components

ABB. Replacement Components Replacement Components Low Voltage Switchgear & Power Circuit Breakers Medium Voltage Switchgear & Circuit Breakers Medium Voltage Switches & Motor Controls Distribution Breakers ABB Customers Choose ABB

More information

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG Medium-Voltage Equipment Selection and Ordering Data Catalog HG 11.02 2011 Answers for energy. R-HG11-172.tif 2 Siemens HG 11.02 2011 Contents SION Vacuum Circuit-Breakers Medium-Voltage Equipment Catalog

More information

Powering business worldwide

Powering business worldwide Powering business worldwide Eaton delivers the power inside hundreds of products that are answering the demands of today s fast changing world. We help our customers worldwide manage the power they need

More information

Contactors & Fuses. Power Breakers, Power Breakers, Contactors & Fuses Contents

Contactors & Fuses. Power Breakers, Power Breakers, Contactors & Fuses Contents - December 00 Power Breakers, Contactors & Fuses Contents Description Page Power Circuit Breakers Low Voltage Power Breakers.................................... - Magnum Family...........................................

More information

Type SDV6 distribution circuit breaker. Top performance - proven reliability. Answers for energy.

Type SDV6 distribution circuit breaker. Top performance - proven reliability. Answers for energy. Type SDV6 distribution circuit breaker Top performance - proven reliability Answers for energy. Table of contents Introduction 2-4 Type 3AH3 stored-energy operating mechanism 6 Vacuum interrupters 7 Ratings

More information

Product Specification Guide. Title: Southern States 72 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

Product Specification Guide. Title: Southern States 72 kv RLSwitcher Vertical Interrupter Style Reactor Switcher TABLE OF CONTENTS PAGE 1.0 SCOPE... 2 2.0 STANDARDS... 2 3.0 DESIGN REQUIREMENTS... 2 3.01 Service Conditions... 2 3.02 Ratings... 3 3.03 Interrupter... 3 3.04 SF6 Gas System... 4 3.05 Terminal Pads...

More information

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG Medium-Voltage Equipment Selection and Ordering Data Catalog HG 11.0 008 Answers for energy. R-HG11-17.tif Siemens HG 11.0 008 Contents Contents Page SION Vacuum Circuit-Breakers Description General Construction

More information

Selection and Application Guide Supplement. WL UL Pole Circuit Breakers. usa.siemens.com/wlbreaker

Selection and Application Guide Supplement. WL UL Pole Circuit Breakers. usa.siemens.com/wlbreaker Selection and Application Guide Supplement WL UL1066 4-Pole Circuit Breakers usa.siemens.com/wlbreaker WL Power Circuit Breaker Table of Contents Ratings for UL 1066 (ANSI C37) Circuit Breakers Frame size

More information

Horizontal Circuit Switchers

Horizontal Circuit Switchers > Transformer Protection > CIRCUIT SWITCHERS C A T A L O G B U L L E T I N General Application Southern States Types CSH and CSH-B Horizontal Circuit Switchers provide an economical, versatile, space saving

More information

Product Specification Guide. Title: Southern States 362 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

Product Specification Guide. Title: Southern States 362 kv RLSwitcher Vertical Interrupter Style Reactor Switcher TABLE OF CONTENTS PAGE 1.0 SCOPE... 2 2.0 STANDARDS... 2 3.0 DESIGN REQUIREMENTS... 2 3.01 Service Conditions... 2 3.02 Ratings... 2 3.03 Interrupter... 3 3.04 SF6 Gas System... 4 3.05 Terminal Pads...

More information

Medium Voltage Equipment 5-15 kv GM-SG and 38 kv GM38 Metal-Clad Switchgear General

Medium Voltage Equipment 5-15 kv GM-SG and 38 kv GM38 Metal-Clad Switchgear General 13 SWITCHGEAR Medium Voltage Equipment -1 kv GM-SG and 38 kv GM38 Metal-Clad Switchgear General Overview Features Siemens, 7, 1 and 38kV class medium voltage, one- or two-high vacuum circuit breaker switchgear

More information

www. ElectricalPartManuals. com RENEWAL PARTS DATA Westinghouse Electric Corporation WESTINGHOUSE EQUIPMENT FOR FURNISHED TO

www. ElectricalPartManuals. com RENEWAL PARTS DATA Westinghouse Electric Corporation WESTINGHOUSE EQUIPMENT FOR FURNISHED TO RENEWAL PARTS DATA FOR WESTINGHOUSE EQUIPMENT FURNISHED TO WESTINGHOUSE ELECTRIC CORPORATION Sharon Plant Sharon Pennsylvania Purchaser's Order C&E-D-44252 G.O. XY-9286-UY-UR - S.O. 2-Y-774 SWITCHGEAR

More information

Cutler-Hammer. Installation Instructions for Undervoltage Release Mechanism (Handle Reset) with LED for E 2 L and E 2 LM Mining Circuit Breakers

Cutler-Hammer. Installation Instructions for Undervoltage Release Mechanism (Handle Reset) with LED for E 2 L and E 2 LM Mining Circuit Breakers Cutler-Hammer Installation Instructions for Undervoltage Release Mechanism (Handle Reset) with LED for E 2 L and E 2 LM Mining Circuit Breakers CONTACT WITH ENERGIZED EQUIPMENT CAN RESULT IN DEATH, SEVERE

More information

CR193 B,C,D and E Vacuum Limitamp * Contactors

CR193 B,C,D and E Vacuum Limitamp * Contactors GE Industrial Solutions CR19 B,C,D and E Vacuum Limitamp * Contactors Renewal Parts Bulletin Table of Contents General Information... Contactor Matrix... 4 Mounting Plates, Pull Handle, Interlock Driver

More information

SWITCHGEAR DIVISION PRODUCT PROFILES

SWITCHGEAR DIVISION PRODUCT PROFILES SWITCHGEAR DIVISION PRODUCT PROFILES Metal-Enclosed Load-Interrupter Switchgear Product Profiles Three-Phase, Group-Operated Load-Interrupter Switches with Fuses in Single and Multi-Bay Assemblies Manual,

More information

Dead Tank Circuit Breaker 145PM40-C Compact design with enhanced reliability

Dead Tank Circuit Breaker 145PM40-C Compact design with enhanced reliability Dead Tank Circuit Breaker 145PM40-C Compact design with enhanced reliability ABB innovations for changing demands ABB (www.abb.com) is a leader in power and automation technologies that enables utility

More information

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories Manual motor protectors Manual motor protectors Manual motor Protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certified

More information

Cutler-Hammer. January 2001

Cutler-Hammer. January 2001 Cutler-Hammer Vol. -2 Product Line Overview Vol. 1, Ref. No. [0468] Product Line Description Cutler-Hammer Molded Case s are designed to provide circuit protection for low voltage distribution systems.

More information

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

The breakers offer thermal-magnetic trip protection according to Z and K characteristics. Series High Performance Circuit Breakers Description The high performance MCB offers a compact solution to circuit protection. The devices are DIN rail mounted. The is available with application-specific

More information

SIEMENS-ALLIS. Medium Voltage. Metalclad Switchgear. www. ElectricalPartManuals. com

SIEMENS-ALLIS. Medium Voltage. Metalclad Switchgear. www. ElectricalPartManuals. com SEMENS-ALLS Medium Voltage Metalclad Switchgear Page 2 Typical Arrangements Auxiliary Cell Over 2000A Breaker Cell A Breaker Cell Over A Breaker Cell --!1 A Breaker Cell Over 2000A Breaker Cell Auxiliary

More information

SF 6 gas insulated RMU SafePlus 24 kv. ABB SafePlus 24 kv SF6 gas insulated RMU 1

SF 6 gas insulated RMU SafePlus 24 kv. ABB SafePlus 24 kv SF6 gas insulated RMU 1 SF 6 gas insulated RMU SafePlus 24 kv 25.03.2010 SafePlus 24 kv SF6 gas insulated RMU 1 Secondary distribution 400 kv Transmission substation Transformer 40-70 kv 130 kv Main Substation Secondary distribution

More information

ABB Components. Switchgear, Distribution Breakers and Reclosers. ABB Power Distribution

ABB Components. Switchgear, Distribution Breakers and Reclosers. ABB Power Distribution ABB Components Switchgear, Distribution Breakers and Reclosers ABB Power Distribution Meeting Customer Needs As a winner of ABB s prestigious Customer Focus Achievement Award and the Award of Excellence,

More information

A Summary of Major Improvements to the ABB Recloser and Type R Breaker

A Summary of Major Improvements to the ABB Recloser and Type R Breaker A Summary of Major Improvements to the ABB Recloser and Type R Breaker Table of Contents Introduction....................................................................3 Center Bumper..................................................................4

More information

Air-insulated medium-voltage secondary distribution switchgear

Air-insulated medium-voltage secondary distribution switchgear DISTRIBUTION SOLUTIONS UniSec for solar applications Air-insulated medium-voltage secondary distribution switchgear Safe, tested application Complete, compact solution Can be installed in containers UniSec

More information

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work Section 16435 - SWITCHBOARDS Introduction Part 1 - General Related Work Section 16070 Seismic Anchorage and Restraint Section 16075 Electrical Identification Section 16080 Power Distribution Acceptance

More information

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers IEC Rated C60N/H/L Circuit Breakers Standard Features Fast Closing Allows increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when

More information

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (38KV) SUBSTATION VACUUM CIRCUIT BREAKER (38KV) For more than four decades, Myers Power Products has led the switchgear market in quality for the electric industry, delivering highly reliable products for utilities

More information

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV) SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV) For more than four decades, Myers Power Products has led the switchgear market in quality for the electric industry, delivering highly reliable products

More information

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV) SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV) For more than four decades, Myers Power Products has led the switchgear market in quality for the electric industry, delivering highly reliable products for utilities

More information

QO and QOU Miniature Circuit Breakers QO Circuit Breaker Accessories

QO and QOU Miniature Circuit Breakers QO Circuit Breaker Accessories QO and Miniature ircuit reakers QO ircuit reaker ccessories lass 1130 / Refer to atalog 0730T9801 IRUIT RKRS ccessories for Use with QO and QO Miniature ircuit reakers Handle ttachments escription at.

More information

Horizontal Circuit Switchers

Horizontal Circuit Switchers > Transformer Protection > CIRCUIT SWITCHERS C A T A L O G B U L L E T I N General Application Southern States Types CSH and CSH-B Horizontal Circuit Switchers provide an economical, versatile, space saving

More information

Westinghouse Breaker Maintenance Manual READ ONLINE

Westinghouse Breaker Maintenance Manual READ ONLINE Westinghouse Breaker Maintenance Manual READ ONLINE If searched for a book Westinghouse breaker maintenance manual in pdf form, in that case you come on to the correct website. We presented the utter edition

More information

www. ElectricalPartManuals. com BBC Brown Boveri Electric Renewal Parts 1-T -E Low-Voltage Power Circuit Breakers

www. ElectricalPartManuals. com BBC Brown Boveri Electric Renewal Parts 1-T -E Low-Voltage Power Circuit Breakers i BBC BROWN BOVERI Type LK and LKE 800 thru 4200 Amperes Type LKD 800 and 1600 Amperes 600 Volts RP 6118A Renewal Parts 1-T -E Low-Voltage Power Circuit Breakers Brown Boveri Electric RP 6118-1A Page 2

More information

BHARAT HEAVY ELECTRICALS LIMITED, JHANSI

BHARAT HEAVY ELECTRICALS LIMITED, JHANSI BHARAT HEAVY ELECTRICALS LIMITED, JHANSI DESIGN, MANUFACTURING, TESTING, SUPPLY INSTALLATION AND COMMISSIONING OF 11KV VACUUM CIRCUIT BREAKER NOTE : 1 VENDOR must submit complete information against clause

More information

Eaton Cutler Hammer Circuit Breaker Manual

Eaton Cutler Hammer Circuit Breaker Manual Eaton Cutler Hammer Circuit Breaker Manual If you are looking for the ebook Eaton cutler hammer circuit breaker manual in pdf form, then you have come on to the loyal site. We presented utter variant of

More information

Vacuum Circuit Breaker VS1

Vacuum Circuit Breaker VS1 Vacuum Circuit Breaker VS1 Product features Conform to GB, IEC, DL and JB standards KEMA type test Level A certificate Ideal contact material and shape, ensuring low current carrying value and stable contact

More information

A200 NEMA Contactors and Starters A200

A200 NEMA Contactors and Starters A200 Starters Non-reversing and Reversing 11 Not to be used for construction purposes unless approved. Table 11. Open Reversing Starters Dimensions NEM of Poles Fig. Mounting Dimensions in Inches (mm) Screws

More information

Magnum IEC Air Circuit Breakers and Drawout Cassette Engineering Data

Magnum IEC Air Circuit Breakers and Drawout Cassette Engineering Data Effective May 2003 Magnum IEC Air Circuit Breakers and Drawout Cassette Engineering Data Magnum IEC Air Circuit Breaker Product Family The New Magnum Narrow Frame Drawout Breaker and Cassette TD030003E

More information

5H KA, RMS C/L Recommendations for Stock POLE UNIT PARTS ARC CHUTE DETAILS. Core, Fig. 17, It.

5H KA, RMS C/L Recommendations for Stock POLE UNIT PARTS ARC CHUTE DETAILS. Core, Fig. 17, It. /' - @Assembed Switchgear Unit Ouantity Stye Number # 50B82G0 # 677C885G0 # 506A098G0 2# 506A099G0 42DH9GO TYPE 50-DH-P-2 '0 DE-ION AIR CIRCUIT BREAKER I '200 Amperp -. 6 KV - 60 Cyce - : Poe :2000 Ampere-

More information

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

Specification for 70mm pole pitch Air circuit breaker up to 1600 A Specification for 70mm pole pitch Air circuit breaker up to 1600 A Protective device for low voltage electrical installation Last update :2011-07-08-1 - Table of contents: 1 General...3 2 Compliance with

More information

BBC. Renewal Parts. I-T-E Low-Voltage Power Circuit Breakers

BBC. Renewal Parts. I-T-E Low-Voltage Power Circuit Breakers BBC BROWN BOVERI RP 6..2.8-2C Renewal Parts I-T-E Low-Voltage Power Circuit Breakers Type K-000, 4000, 0008, and 40008 Stationary and Drawout Mounted 000 and 4000 Amperes 600 Volts RP 6..2.8-2 Page 2 Table

More information

Siemens AG Catalog HG11.07 Edition 10/ AE6 Medium-Voltage Equipment. siemens.com/sion

Siemens AG Catalog HG11.07 Edition 10/ AE6 Medium-Voltage Equipment. siemens.com/sion Siemens AG 2018 Catalog HG11.07 Edition 10/ 2018 SION Lateral Vacuum Circuit-B Breaker with Laterrall Operating Mechaniism m 3AE6 Medium-Voltage Equipment siemens.com/sion 2 Catalog HG11.07 10 / 2018 SION

More information

TRT SYSTEM. Product Description

TRT SYSTEM. Product Description TRT SYSTEM Product Description The TRT is a machine that exploits the flow and the pressure of the furnace output gas to produce electric energy. Through a system of regulation managed by PLC it maintains

More information

www. ElectricalPartManuals. com POWER CIRCUIT BREAKERS TYPES AK-2/3/2A/3A-50, AKU-2/3/2A/3A-50, AKT-2/3/2A/3A-50 GENERAL fj ELECTRIC

www. ElectricalPartManuals. com POWER CIRCUIT BREAKERS TYPES AK-2/3/2A/3A-50, AKU-2/3/2A/3A-50, AKT-2/3/2A/3A-50 GENERAL fj ELECTRIC ORDERNG NSTRUCTONS. Always specify complete nameplate data of the breaker. 2. Specify the quantity, catalog number (if listed), reference number (if listed), description, and this bulletin number. 3. Standard

More information

2.0 CONSTRUCTION 3.0 OPERATION. SA-1 Generator Differential Relay - Class 1E 2.5 TRIP CIRCUIT

2.0 CONSTRUCTION 3.0 OPERATION. SA-1 Generator Differential Relay - Class 1E 2.5 TRIP CIRCUIT 41-348.11C SA-1 Generator Differential Relay - Class 1E 2.0 CONSTRUCTION The type SA-1 relay consists of: Restraint Circuit Sensing Circuit Trip Circuit Surge Protection Circuit Operating Circuit Amplifier

More information

Merlin Gerin 2018 Amp 15kv Breaker Manual

Merlin Gerin 2018 Amp 15kv Breaker Manual Merlin Gerin 2018 Amp 15kv Breaker Manual If you are searched for a ebook Merlin gerin 2018 amp 15kv breaker manual in pdf format, then you've come to the faithful website. We presented utter version of

More information

PowerPact B. Molded case circuit breakers and switches from A

PowerPact B. Molded case circuit breakers and switches from A PowerPact B Molded case circuit breakers and switches from 15-125 A 2 schneider-electric.us Efficiency that clicks. PowerPact B molded case circuit breakers Schneider Electric introduces a new family member

More information

Tmax Molded Case Circuit Breakers

Tmax Molded Case Circuit Breakers Tmax Molded Case Circuit s Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product technology. Never before has the industry seen such high

More information

Descriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications

Descriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications Descriptive bulletin Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications General overview Reliable, low maintenance and economical Load Interrupter

More information

Submersible Vacuum Fault Interrupters

Submersible Vacuum Fault Interrupters Submersible Vacuum Fault Interrupters UG Distribution Medium Voltage Vacuum Fault Interrupters Functional Specification Guide PS024002EN Functional Specification for 2.4kV to 17.5kV UG Distribution Medium

More information

Circuit Breakers Naval Shipboard Use

Circuit Breakers Naval Shipboard Use Circuit Breakers Naval Shipboard Use Circuit Breakers for Naval Shipboard Use Contents Description Page Description Page Description Page Description Page Selector Guide for Navy Circuit Breakers......

More information

SL Series IEC Vacuum Contactors. Medium Voltage Contactors Technical Focus

SL Series IEC Vacuum Contactors. Medium Voltage Contactors Technical Focus Medium Contactors Technical Focus Automotive Powering business worldwide Aerospace Eaton delivers the power inside hundreds of products that are answering the demands of today s fast changing world. We

More information

IL131029EN. Instructions for the 15kV VCP-W 25-63kA Simple Manual Ground and Test Device

IL131029EN. Instructions for the 15kV VCP-W 25-63kA Simple Manual Ground and Test Device Instructions for the 15kV VCP-W 25-63kA Simple Manual Ground and Test Device Eaton Electrical Power Components Division Moon Twp, PA. U.S.A. 15108 JULY 2016 1 Figure 1: Device shown with upper terminals

More information

RENEWAL PARTS I C302AA A-2 300V AB A-4800V A C A -SOOOV PARTS RECOMMENDED FOR NORMAL STOCK

RENEWAL PARTS I C302AA A-2 300V AB A-4800V A C A -SOOOV PARTS RECOMMENDED FOR NORMAL STOCK NGrE: RENEWAL PARTS IC0A HIGH VOLTAGE CONTACTORS I C0AA 00A 00V AB00A800V A C 00A SOOOV PARTS RECOMMENDED FOR NORMAL STOCK The current is identified by the number following the voltage letter in the IC

More information

SDV7. Outdoor distribution circuit breaker family 15.5 kv to 38.0 kv. usa.siemens.com/sdv7

SDV7. Outdoor distribution circuit breaker family 15.5 kv to 38.0 kv. usa.siemens.com/sdv7 0 000 0000000 0000 000000 0000 000 0000000 0000 000000 0000 000 0000000 SDV7 Outdoor distribution circuit breaker family 5.5 kv to 8.0 kv usa.siemens.com/sdv7 SDV7 Brochure Brochure SDV7 The type SDV7

More information

Low breaking capacity moulded case circuit breakers

Low breaking capacity moulded case circuit breakers New series EB2S of MCCBs has excellent performances with reduced dimensions and new modern design. Advantages of low breaking capacity MCCBs Unique accessory cover opens with only one screw. Practical

More information

Technical Data and Specifications. Table UL 489/IEC Interrupting Capacity Ratings. cu I cs I cu I cs I cu I cs I cu I cs I cu I cs

Technical Data and Specifications. Table UL 489/IEC Interrupting Capacity Ratings. cu I cs I cu I cs I cu I cs I cu I cs I cu I cs -14 1 Amperes November 08 Eaton s Cutler-Hammer EG Product Description EG breaker is HACR rated. Technical Data and Specifications Table -6. UL 489/IEC 947-2 Interrupting Capacity Ratings Circuit Interrupting

More information

Switches Unlimited Phone: * Fax:

Switches Unlimited Phone: * Fax: For Info: sales@switchesunlimited.com www.switchesunlimited.com Phone: 800-1-0487 Fax: 718-67-6370 Page -4 Page -8 THREE-POLE CONTACTORS IEC Ith ratings in AC1 duty at 40 C: 16 to 1600A IEC Ie ratings

More information

DEF 005. WavePro Power Circuit Breakers A Frames, Vac. Renewal Parts

DEF 005. WavePro Power Circuit Breakers A Frames, Vac. Renewal Parts g DEF 005 WavePro Power Circuit Breakers 3200 5000 A Frames, 240 600 Vac Introduction This guide contains a listing of the parts and assemblies that are available as replacement parts for WavePro 3200

More information

12kV W-VACi Series Medium Voltage Vacuum Circuit Breaker

12kV W-VACi Series Medium Voltage Vacuum Circuit Breaker Automotive Powering business worldwide Aerospace Eaton delivers the hundreds of power distribution products that are answering the demands of today s fast changing world. We help our customers worldwide

More information

Type SDV7 distribution circuit breaker family

Type SDV7 distribution circuit breaker family www.usa.siemens.com/sdv7 Type SDV7 distribution circuit breaker family 5.5 kv to 8.0 kv Answers for infrastructure. Table of contents Introduction 0 Vacuum interrupters 0 Simple current path 05 Low-maintenance

More information

ABB Components. Switchgear, Distribution Breakers and Reclosers

ABB Components. Switchgear, Distribution Breakers and Reclosers ABB Components Switchgear, Distribution Breakers and Reclosers Meeting Customer Needs As a winner of ABB s prestigious Customer Focus Achievement Award and the Award of Excellence, the Components Group

More information

Page 2-4 Page 2-8. Page Page 2-13

Page 2-4 Page 2-8. Page Page 2-13 Page -4 Page -8 THREE-POLE CONTACTORS IEC Ith ratings in AC1 duty at 40 C: 16 to 1600A IEC Ie ratings in AC3 440V duty: 6 to 630A IEC Power ratings in AC3 400V duty:. to 335kW UL/CSA ratings: 3 to 500HP

More information

Ampgard medium voltage motor control renewal parts

Ampgard medium voltage motor control renewal parts Technical Data TD020001EN Contents Description Page General information.... 2 3 400A starter design.... 4 9 800A starter design.... 10 15 Control and potential transformers.... 16 Current transformers....

More information

3VT Kompaktleistungsschalter bis 630A

3VT Kompaktleistungsschalter bis 630A Katalog LV 36 AT Österreich - Auszug 2012 3VT Kompaktleistungsschalter bis 630A SENTRON Schutz-, Schalt- und Messtechnik www.siemens.com/lowvoltage 3VT1 Molded Case Circuit Breakers up to 160 A 1 Technical

More information

30 ma Ground Fault (Earth Leakage) Modules. Product Description

30 ma Ground Fault (Earth Leakage) Modules. Product Description August 2006 0 ma Ground Fault (Earth Leakage) Modules 5-0 ma Ground Fault (Earth Leakage) Modules Clockwise from Left:,, MCCBs Shown with Ground Fault (Earth Leakage) Modules Product Description Eaton

More information

Instructions for the Use, Operation and Maintenance of Types VCP-TL and VCP-TRL Linear Magnetic Vacuum Circuit Breakers

Instructions for the Use, Operation and Maintenance of Types VCP-TL and VCP-TRL Linear Magnetic Vacuum Circuit Breakers Instructions for the Use, Operation and Maintenance of Types VCP-TL and VCP-TRL Linear Magnetic Vacuum Circuit Breakers Effective May 2016 VCP-TRL Fixed (shown with optional protective relay installed)

More information

DPX 1600 Electronic release

DPX 1600 Electronic release 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 1600 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND

More information

Vacuum Circuit Breaker Type VAD-3

Vacuum Circuit Breaker Type VAD-3 Instruction Bulletin Bulletin 6055-11 Vacuum Circuit Breaker Type VAD-3 4.76 kv, 29 ka (250 MVA) 4.76 kv, 41 ka (350 MVA) 8.25 kv, 33 ka (500 MVA) 15.0 kv, 18 ka (500 MVA) 15.0 kv, 28 ka (750 MVA) 15,0

More information

www. ElectricalPartManuals. com

www. ElectricalPartManuals. com ---- ----------- --- Page 2 Description and Application VacCiad-W Metal-Clad Switchgear is an integrated assembly of drawout vacuum circuit breakers, bus, and control devices coordinated electrically and

More information