2 content Technical data page 3 Manual page 5 Hydraulic Schematic page 6 Electrical wiring diagram page 7 Parts Plan page 8 Parts List page 9

3 Technical data Engine construction motor power Three-phase motor 1,1kW in continuous operation Hydraulikpumpe constrction 3-stage Radial piston pump flow 7,2 l/min bis 70 bar 2,5 l/min bis 200 bar 0,9 l/min bis 800 bar maximum pressure 800 bar hydraulic control Wegeventil construction 4/2-poppet valve, electromagnetically actuated flow max. 12 l/min maximum pressure 800 bar actuating voltage 1~400V 50Hz Druckventil (Drehmomentventil) construction spring-loaded Ball seat valve, manually adjustable flow max. 12 l/min maximum pressure 800 bar adjustment ca. 25 bis 800 bar Rückdruckventil construction spring-loaded cone seat valve, fixed flow max. 15 l/min maximum pressure 215 bar adjustment ca. 25 bis 110 bar Manometer construction Bourdon gauge, glycerine filled size Ø100 mm accuracy Kl. 1,0

4 Technical data dimensions and weights main dimensions weight without oil Gewicht operational LxBxH440x240x470 mm 22,0 kg 28,0 kg oil filling capacity 6 l viscosity ISO VG 46 protection protection class IP 54 Attention: No ex. protection!

5 Operation Manual Prior to using the pump Using the dipstick check the oil level in the tank. Check the pump, remote control and hydraulic twin line hoses for signs of damage. Connect the remote control unit. Connect the hydraulic hoses to the pump and tool ensuring that the couplings are free of grit or dirt. Ensure that the torque control valve is set to zero by fully rotating it counter-clockwise. Connect the pump to the correct electrical supply. (See unit for details) Operation Start the motor by pressing and releasing the white button on the remote control. The tool is pressurised by holding the white button down and depressurised by releasing it. Pressing the black button on the remote control the motor stops. The motor will be stopped automatically after approximately 1 minute without any operation of the remote control. Torque setting While the motor is running press the white button on the remote control and hold it until the piston is fully advanced. Continue to hold the white button and slowly rotate the torque control valve in a clockwise direction until the required pressure/torque is shown on the pressure gauge. The white button should then be released, allow the piston to fully retract and then operate the unit one more time to check the output pressure/torque is correct. If not repeat. To reduce the pressure/torque turn the torque control valve anti-clockwise. If the desired pressure/torque has been reached rotate the wing nut on the torque control valve clockwise. This will lock the torque control valve in place. To achieve full torque it is important that the wing nut on the torque control valve is rotated fully anti-clockwise against the bottom of torque control valve and that the torque control valve is turned fully clockwise. Tightening and loosening bolts For bolting consult the tool manual. After use Switch off the motor using the black switch on the remote control unit. Turn off the electrical supply. Having ensured that hydraulic pressure has been released, disconnect the hydraulic hoses.

6 Hydraulikschaltplan

7

8

9 Hydraulic Power Console HE V Parts List Pos. designation part Number 1 Electric motor control DAS71G k 2 Pump unit complete KP Wear rate for pumping unit VS KP oil tank incl gasket AB 7 D GK 4 Oil drain screw GN740-G1/4 5 Ölschauglas mit Thermometer GN B 6 bleed screw GN G3/8-A-2 7 valve block compl. MI 230V 800bar 8 clutch Kit Cejn pressure adjusting valve (new) MVE4AR pressure adjusting valve (exchange) MVE4AR-700 AT 10 manometer NG b Kl 1,0 11 solenoid valve WG4-1 R WG230V 12 carrying handle TR DKW oil cooler V 14 remote Control (no picture) FB el. 5m k

TPV Variable Displacement Closed Loop System Axial Piston Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 851 / 0813 / E

TPV Variable Displacement Closed Loop System Axial Piston Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 851 / 0813 / E HYDRAULIC COMPONENTS HYDROSTATIC TRANSMISSIONS GEARBOXES - ACCESSORIES THE PRODUCTION LINE OF HANSA-TMP Variable Displacement Closed Loop System CONTENTS General Information... Order Code... Manual Control

More information

Variable Displacement Open Loop Circuit Axial Piston Pumps. V Series

Variable Displacement Open Loop Circuit Axial Piston Pumps. V Series HYDRAULIC COMPONENTS HYDROSTATIC TRANSMISSIONS GEARBOXES - ACCESSORIES Via M. L. King, 6-41122 MODENA (ITALY) Tel: +39 59 415 711 Fax: +39 59 415 729 / 59 415 73 INTERNET: http://www.hansatmp.it E-MAIL:

More information

V Series AXIAL PISTON PUMP ORDER CODE

V Series AXIAL PISTON PUMP ORDER CODE V Series AXIAL PISTON PUMP ORDER CODE V 15 A 1 R B S - A 1 D X A 11 Customers demand Pump Series V Links Type (only V 15-18): none - Standard A - SAE A 2 bolts Ma. Displacement (cm 3 /n): 15, 18, 23, 25,

More information

TPV Variable Displacement Closed Loop System Axial Piston Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 852 / 0815 / E

TPV Variable Displacement Closed Loop System Axial Piston Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 852 / 0815 / E HYDRAULIC COMPONENTS HYDROSTATIC TRANSMISSIONS GEARBOXES - ACCESSORIES Certified Company ISO 9001-14001 ISO 9001 Via M. L. King, 6-41122 MODENA (ITALY) Tel: +39 059 415 711 Fax: +39 059 415 729 / 059 415

More information

Clamping and drive module

Clamping and drive module Clamping and drive module RE 51147/10.05 Replaces: 04.02 1/14 Type UPE 3 Drive power 3.0 kw / 4.0 kw Series 1X Maximum operating pressure 700 bar H6842 Overview of contents Contents Page Features 1 Application

More information

SOLENOID VALVES AND PNEUMATIC VALVES

SOLENOID VALVES AND PNEUMATIC VALVES A S E R I E S Catalogue 001 Directly operated solenoid valves Series A / way, 3/ way monostable, stable (with magnetic memory) Ports M5, G1/8, cartridge ø 4 The Series A solenoid valves are of the directly

More information

Operating Instructions

Operating Instructions Beuler Höhe 11, D-45525 Hattingen Tel. +49(0)2324/55515 info@stephandahlmann.de www.stephandahlmann.com Operating Instructions Contents Page 1. Designation and Illustration of the Machine 1 2. EC Declaration

More information

Special valves. Logic components AND/OR Timer 2/2 way screw-in valves Miniature screw-in pressure regulators Relief valves

Special valves. Logic components AND/OR Timer 2/2 way screw-in valves Miniature screw-in pressure regulators Relief valves Contents Description Page Dual-pressure valve (AND) 3 OR valve (OR) 33 Timer 34, 35 / way screw-in valves 36, 37 Miniature screw-in pressure regulators 38, 39 Relief valves 40 Special valves Logic components

More information

3/2 Way Valve G1/8. Data Sheet No E. Characteristics Symbol Unit Description General Features Spool valve.

3/2 Way Valve G1/8. Data Sheet No E. Characteristics Symbol Unit Description General Features Spool valve. AP64E00DX00X Characteristics to VDI 90 Pressures quoted as gauge pressure Characteristics Symbol Unit Description General Features Spool valve Mounting screws M Tube connection Thread Port size ; 7.4 deep

More information

Axial Piston Variable Pump A2VK

Axial Piston Variable Pump A2VK Axial Piston Variable Pump A2VK RE 94001/06.10 1/12 Replaces: 07.04 Data sheet Size 12 to 107 Series 1 and 4 Nominal pressure 250 bar Maximum pressure 315 bar Version for pumping plastic components Contents

More information

WESCO INDUSTRIAL PRODUCTS, INC. Manual Non Telescoping High Lift Truck. Part Number: &

WESCO INDUSTRIAL PRODUCTS, INC. Manual Non Telescoping High Lift Truck. Part Number: & WESCO INDUSTRIAL PRODUCTS, INC Manual Non Telescoping High Lift Truck Part Number: 272462 & 272463 Note: Operator MUST read and understand these operating instructions before using this Truck. TABLE OF

More information

Axial piston pumps type PVPC variable displacement, by a full line of mechanical controls

Axial piston pumps type PVPC variable displacement, by a full line of mechanical controls www.atos.com Table A600/E Axial piston pumps type PVPC variable displacement, by a full line of mechanical controls PVPCCH4046 PVPC are variable displacement axial piston pumps for high pressure operation,

More information

V Series AXIAL PISTON PUMP ORDER CODE

V Series AXIAL PISTON PUMP ORDER CODE V Series AXIAL PISTON PUMP ORDER CODE V A 1 R B S - A D X A 1 Customers demand Pump Series V Links Type (only V -18): none - Standard A - SAE A bolts Ma. (cm 3 /n):, 18, 3,, 38, 4,, 7 Pump Control Type

More information

Cleanline portable. Oil Service Units FA 016 / FAPC 016

Cleanline portable. Oil Service Units FA 016 / FAPC 016 Oil Service Units Cleanline portable FA 016 / FAPC 016 Easy filling and cleaning Compact design, comfortable handling High filtration efficiency Option: with oil cleanliness monitor FAPC 016 with data

More information

Flow Control Valve. 1 Description. 2 Symbols. Series SRCA General. 1.2 Application examples way flow control way flow control

Flow Control Valve. 1 Description. 2 Symbols. Series SRCA General. 1.2 Application examples way flow control way flow control Flow Control Valve Series SRC.. plug-in coil for easy coil change flow rates are unaffected by changes in temperature or load compact design reduced p ZnNi coating (>70h DIN EN ISO 97 NSS) Description.

More information

Examples 3/2-way valve A T NO: Symbol

Examples 3/2-way valve A T NO: Symbol 1/1 Hauhinco-3_2-way valve_b1_dn3-25_pn320_pn500_x,y-intern water s 01/2016 3/2-way valve B1 X,Y - DN3 DN25 PN320, PN500 Features: Hydraulically actuated directional seat valve controlling liquid media.

More information

FA 016 FAPC 016. Oil Service Units. Description. Page 53

FA 016 FAPC 016. Oil Service Units. Description. Page 53 Oil Service Units FA 016 FAPC 016 Easy filling and cleaning Compact design, comfortable handling High filtration efficiency Option: with oil cleanliness monitor and data storage Description FA 016 With

More information

XP-115 Multi-Port Power Pack Operation and Maintenance Manual

XP-115 Multi-Port Power Pack Operation and Maintenance Manual XP-115 Multi-Port Power Pack Operation and Maintenance Manual http://www.torsionx.com Safety Guide To use the XP-115 Multi-Port Power Pack safely you must follow correct operation guidelines and inspect

More information

MOTORS M HYDRAULIC MOTORS

MOTORS M HYDRAULIC MOTORS MOTORS M HYDRAULIC MOTORS T E C H N I C A L C A T A L O G Fixed displaced axial piston motors POCLAIN HYDRAULICS Displacement cm³/rev [in³/rev.] M0 M1 M2 M3 From 7,07 [0.43] to 17,84 [1.09] From 9,08 [0.55]

More information

Directional Seat Valve Series D4S (Denison)

Directional Seat Valve Series D4S (Denison) Characteristics Seat valves series D4S are designed for directional control functions. A large variety of poppets, springs and covers - including shuttle valves, stroke limiters, solenoid valves (VV01)

More information

nickel-plated brass - PBT technopolymer HNBR, FKM stainless steel

nickel-plated brass - PBT technopolymer HNBR, FKM stainless steel CATALOGUE > Release 8.8 > Series A solenoid valves Series A directly operated solenoid valves /-way - Normally Closed (NC) and Normally Open (NO) 3/-way - Normally Closed (NC) and Normally Open (NO)»»

More information

Flow Control Valve. 1 Description. 2 Symbols. Series SRCA General. 1.2 Application examples way flow control way flow control

Flow Control Valve. 1 Description. 2 Symbols. Series SRCA General. 1.2 Application examples way flow control way flow control Flow Control Valve Series SRC.. plug-in coil for easy coil change flow rates are unaffected by changes in temperature or load. compact reduced p ZnNi coating (>70h DIN EN ISO 97 NSS) Description. General

More information

PROPORTIONAL VALVES SERVO VALVES. Maximum operating pressure MPa {kgf/cm 2 } Model [Model No.]

PROPORTIONAL VALVES SERVO VALVES. Maximum operating pressure MPa {kgf/cm 2 } Model [Model No.] J PROPORTIONAL VALVES SERVO VALVES J Model [Model No.] Solenoid pilot operated proportional relief valve [JRP] Solenoid operated proportional relief valve [JRPL] Type C2 solenoid operated proportional

More information

Instruction Manual. High Lift Hand Truck

Instruction Manual. High Lift Hand Truck Instruction Manual High Lift Hand Truck Note: The Owner/Operator must read carefully and understand all the information presented here before operation. CONTENT 1. Specification. 2 2. Safety Instructions...

More information

XP-AIR Multi-Port Power Pack Operation and Maintenance Manual

XP-AIR Multi-Port Power Pack Operation and Maintenance Manual XP-AIR Multi-Port Power Pack Operation and Maintenance Manual http://www.torsionx.com Safety Guide To use the XP-AIR Multi-Port Power Pack safely you must follow correct operation guidelines and inspect

More information

nickel-plated brass - PBT technopolymer HNBR, FKM stainless steel

nickel-plated brass - PBT technopolymer HNBR, FKM stainless steel CATALOGUE > Release 8.7 > Series A solenoid valves Series A directly operated solenoid valves /-way, 3/-way NC and NO. Monostable - bistable (with magnetic memory) Ports M5 - G1/8 - R1/8 - cartridge ø4

More information

KLW4000D Multi-Port Power Pack

KLW4000D Multi-Port Power Pack KLW4000D Multi-Port Power Pack Operation and Maintenance Manual Safety Guide To use the KLW4000DMulti-Port Power Pack safely you must follow correct operation guidelines and inspect the equipment regularly.

More information

Radial piston motor for compact drives MCR-C

Radial piston motor for compact drives MCR-C Radial piston motor for compact drives MCR-C RE 15197 Edition: 12.2013 Frame size MCR20 Displacement 1750 cc to 3000 cc Differential pressure up to 450 bar Torque output up to 19099 Nm Speed up to 125

More information

Hydraulic Jacks & Tools Valves

Hydraulic Jacks & Tools Valves Hydraulic Jacks & Tools Valves VH-4/3-1 with VSM-21 VH-4/3-1 VH-3/3-1 VH-4/3-2 VHH-4/3 This port can easily be used to connect a pressure gauge and a pressure relief valve (e.g. VR-1). The oil port T shall

More information

Clamping and drive module

Clamping and drive module Clamping and drive module RE 51142/10.05 Replaces: 11.02 1/8 Type UPE 2 Drive power 1.1 kw / 2.2 kw Series 1X Maximum operating pressure 700 bar UPE2_1X Table of contents Contents Page Features 1 Possible

More information

Operating Instructions

Operating Instructions Beuler Höhe 11, D-45525 Hattingen Tel. +49(0)2324/55515 info@stephandahlmann.de www.stephandahlmann.com Operating Instructions Contents Page 1. Designation and Illustration of the Machine 1 2. EC Declaration

More information

2001 Dodge Dakota ENGINES 4.7L V8

2001 Dodge Dakota ENGINES 4.7L V8 FRONT COVER Removal & Installation 1. Disconnect negative battery cable. Remove drive belt. Remove A/C compressor mounting bolts, and position compressor aside. Drain cooling system. Remove radiator hoses.

More information

Publ. 3-EN 2950-A. DENISON HYDRAULICS Pressure Relief Valve R6V

Publ. 3-EN 2950-A. DENISON HYDRAULICS Pressure Relief Valve R6V Publ. 3-EN 2950-A DENISON HYDRAULICS Pressure Relief Valve R6V FEATURES, SYMBOL FEATURES High Performance: R6V valves are designed for a maximum pressure of 350 bar and a flow capacity up to 650 l/min.

More information

Bimetal Thermometers Model 54, Heavy Duty Series

Bimetal Thermometers Model 54, Heavy Duty Series Mechanical Temperature Measurement Bimetal Thermometers Model 54, Heavy Duty Series WIKA Data Sheet TM 54.01 Applications T Universally suitable for plant, machinery, tank and apparatus construction T

More information

Axial piston pumps type PVPC with ISO mounting flange variable displacement, hydraulic control

Axial piston pumps type PVPC with ISO mounting flange variable displacement, hydraulic control www.atos.com Table TA623/E Axial piston pumps type PVP with ISO mounting flange variable displacement, hydraulic control PVPH4046 PVP are variable displacement axial piston pumps for high pressure operation,

More information

ABSOLUTE EQUIPMENT PTY LTD

ABSOLUTE EQUIPMENT PTY LTD Manual Hydraulic Toe Jack Model DTJ Series ABSOLUTE EQUIPMENT PTY LTD 2/186 Granite Street, GEEBUNG QLD 4034 Australia sales@absoluteequipment.com.au Phone: +61 7 3865 4006 Fax: +61 7 3102 6288 This is

More information

Radial piston motor for frame integrated drives MCR-A

Radial piston motor for frame integrated drives MCR-A Radial piston motor for frame integrated drives MCR-A RE 15195 Edition: 12.2013 Frame size MCR3, MCR5, MCR10 Displacement 160 cc to 1340 cc Differential pressure up to 450 bar Torque output up to 8530

More information

Chapter 10: Valves for Pipe Mounting

Chapter 10: Valves for Pipe Mounting Contents Chapter : Valves for Pipe Mounting Series Description Size Body Page DIN / ISO 1/8 1/4 3/8 1/2 3/4 1 1¼ 1½ 2 L-port T-port Pressure valves, manual operation R4V R4R Pressure relief function Pressure

More information

/2-way piston valves

/2-way piston valves > > ort size: DN 15... 100 Flange connection, ressure rating N 40 > > Valve operates without differential pressure (Zero delta ) > > Suitable for vacuum > > djustable: Damped operation () > > Valve piston

More information

ABSOLUTE EQUIPMENT PTY LTD

ABSOLUTE EQUIPMENT PTY LTD Manual Hydraulic Toe Jack Model DTJ Series ABSOLUTE EQUIPMENT PTY LTD 2/186 Granite Street, GEEBUNG QLD 4034 Australia sales@absoluteequipment.com.au Phone: +61 7 3865 4006 Fax: +61 7 3102 6288 This is

More information

/2-way piston valves

/2-way piston valves > > ort size: DN 15... 100, Flange connection, ressure rating N 40 > > djustable: Damped operation () > > Valve operates without differential pressure (Zero delta ) > > Valve piston with TFE guide-ring

More information

Axial piston pumps type PVPC variable displacement, by a full line of mechanical controls

Axial piston pumps type PVPC variable displacement, by a full line of mechanical controls www.atos.com Table A60/E Axial piston pumps type PVP variable displacement, by a full line of mechanical controls PVPH4046 PVP are variable displacement axial piston pumps for high pressure operation,

More information

Fixed displacement radial piston pump

Fixed displacement radial piston pump Fixed displacement radial piston pump RE 11263/05.13 Replaces: 10.05 1/16 Type R4 izes 1.60 to 20.00 cm 3 Component series 3X Maximum operating pressure 700 bar H7322 2R4-3X/4,00-700RK01M01+AZF8 H7321

More information

Variable Plug-In Motor A6VE

Variable Plug-In Motor A6VE Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service Variable Plug-In Motor A6VE RE 91 606/10.07 1/16 Replaces: 06.05 Technical data sheet Series 6 Size Nominal

More information

4.2 FIXED DISPLACEMENT DOUBLE PUMP

4.2 FIXED DISPLACEMENT DOUBLE PUMP 4.2 FIXED DISPLACEMENT DOUBLE PUMP CONTENTS PVF101 Ordering Code 4.2.1 Fixed Displacement Technical Information 4.2.2 Specifications 4.2.3 Hydraulic fluids 4.2.4 Viscosity range 4.2.5 Temperature range

More information

SPARE PART LIST LW 300 E & LW 450 E

SPARE PART LIST LW 300 E & LW 450 E SPARE PART LIST LW 300 E & LW 450 E Nautico Maldives Pvt Ltd H. Oleander Hiththafinivaa Magu Male' Tel: + 960 31 52 53 Fax: + 960 32 44 96 Mobil: 00960 77 23 81 --------00960 77 88 79 E-mail: nautico@dhivehinet.net.mv

More information

HYDRAULIC POWER UNITS PO 4

HYDRAULIC POWER UNITS PO 4 View product: http://industrial.lukas.com Mobile power for small and medium-sized cylinders. With the compact motor pumps from the PO 4 series, you will be well-equipped if you frequently need to operate

More information

RE 91808/ AA4VSE Plug-in dual displacement motor. High pressure range. Series 10 Axial piston swashplate design, SAE model

RE 91808/ AA4VSE Plug-in dual displacement motor. High pressure range. Series 10 Axial piston swashplate design, SAE model AA4VSE Plug-in dual displacement motor Series Axial piston swashplate design, SAE model RE 91808/09.90 RE 91808/09.90 Brueninghaus Hydromatik Size 250 Nominal pressure 350 bar Peak pressure 400 bar High

More information

LS / LX. Performance under Pressure HYDRAULIC TORQUE WRENCHES

LS / LX. Performance under Pressure HYDRAULIC TORQUE WRENCHES LS / LX HYDRAULIC TORQUE WRENCHES Square drive and low profile hexagon torque wrenches. Robust design to tighten and loosen nuts. Torque accuracy: ±3% across full stroke. Wide range of accessories available.

More information

Filter cooler unit with inline filter according to DIN Type ABUKG. Contents. Features. RE Edition: Replaces: 50126

Filter cooler unit with inline filter according to DIN Type ABUKG. Contents. Features. RE Edition: Replaces: 50126 Filter cooler unit with inline filter according to DIN24550 Type ABUKG RE 50125 Edition: 2013-04 Replaces: 50126 Component series 4X With gerotor pump, external gear pump SILENCE PLUS or screw spindle

More information

86740/ /2-way piston valves

86740/ /2-way piston valves > > ort size: DN 8... 50, G1/4... 2 (ISO G/NT) > > Valve operates without differential pressure (Zero delta ) > > Suitable for vacuum > > Damped operation > > Valve piston with TFE guide-ring Technical

More information

Solenoid Pilot Operated Proportional Directional Control Valve

Solenoid Pilot Operated Proportional Directional Control Valve Solenoid Pilot Operated Proportional Directional Control Valve Features hese solenoid pilot operated proportional directional control valves use a nozzle flapper valve as pilot valve and perform spool

More information

Hydraulic Pumps. Contact us at

Hydraulic Pumps. Contact us at Hydraulic Pumps 230-230- 100-100- 115-115- 110-110- 6153605540 Frame 06.2016 MAX Piston pump 6153605880 Housing 6153605970 Piston pump service Kit 6153605970 Piston pump service Kit 6153605850 (100V, 115V)

More information

Contact dial thermometer

Contact dial thermometer Data Sheet 608523 Page 1/8 Contact dial thermometer Special features Temperature controller with process value display as panel-mounting or add-on device Class 1.5 Protection rating IP 65 Case sizes :

More information

Radial piston motors for industrial applications MCR-D

Radial piston motors for industrial applications MCR-D Radial piston motors for industrial applications MCR-D MCR-E RE 15196 Edition: 02.2017 Replaces: 12.2013 MCR-D Frame size MCR3, MCR5, MCR10 Displacement 160 cc to 1340 cc Differential pressure up to 450

More information

TWO-STAGE HYDRAULIC PUMP. RWP55-IBT-Air

TWO-STAGE HYDRAULIC PUMP. RWP55-IBT-Air ORIGINAL INSTRUCTIONS Form No.1000458 5 SPX Corporation 5885 11th Street Rockford, IL 61109-3699 USA Tech. Services: (800) 477-8326 Fax: (800) 765-8326 Order Entry: (800) 541-1418 Fax: (800) 288-7031 Internet

More information

List of Parts for Screw Compressor VMY 447 H and VMY 447 M Model 1994

List of Parts for Screw Compressor VMY 447 H and VMY 447 M Model 1994 00.08 List of Parts for Screw Compressor VMY 447 H and VMY 447 M Model 994 Relevant drawing: 0664-70 Unless otherwise stated, all measurements are in mm.) Pos. Designation Qty per comp. H M Used w/pos.

More information

Axial piston variable pump A4VG Series 32. Europe. RE-E Edition: Replaces:

Axial piston variable pump A4VG Series 32. Europe. RE-E Edition: Replaces: Axial piston variable pump A4VG Series 32 Europe RE-E 92003 Edition: 04.2016 Replaces: 06.2012 High-pressure pump for applications in a closed circuit Size 28 to 125 Nominal pressure 400 bar Maximum pressure

More information

Axial Piston Variable Pump A2VK

Axial Piston Variable Pump A2VK Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service Axial Piston Variable Pump A2VK RE 94001/06.10 1/12 Replaces: 07.04 Data sheet Size 12 to 107 Series 1

More information

Radial piston pump, fixed displacement

Radial piston pump, fixed displacement Radial piston pump, fixed displacement RE 11260/08.05 Replaces: 07.02 1/8 Type R4 izes 0.40 to 2.00 cm 3 Component series 1X Maximum operating pressure 700 bar R4_d R4-1X/1,00-450WA01M01 Table of contents

More information

RA / Radial Piston Motor Model MR, MRE Fixed Displacement. Table of Contents. Replaces: RA /10.95

RA / Radial Piston Motor Model MR, MRE Fixed Displacement. Table of Contents. Replaces: RA /10.95 Radial Piston Motor Model MR, MRE Fixed Displacement Sizes 160 to 9500 6100 PSI (up to 420 bar) 582 in 3 (up to 9542 cm 3 ) 25,075 lb-ft (up to 34000 Nm) RA 15 228/10.95 Replaces: 12.94 Wide range of displacements

More information

GENERAL PROCEDURES. Component Bleeding. Master Cylinder Priming In-Vehicle or Bench

GENERAL PROCEDURES. Component Bleeding. Master Cylinder Priming In-Vehicle or Bench 206-00-1 Brake System General Information 206-00-1 GENERAL PROCEDURES Component Bleeding Special Tool(s) Worldwide Diagnostic System (WDS) 418-F224, New Generation STAR (NGS) Tester 418-F052, or equivalent

More information

N/** поставка оборудования для подготовки воздуха

N/** поставка оборудования для подготовки воздуха M/0000 Series Inline /, 5/ and 5/ Spool Valves Solenoid and Pilot Actuated G / Low power solenoids High flow Unique steel reinforced seals Light weight corrosion resistant materials Technical Data Medium:

More information

Vickers. Piston Motors. Inline Piston Motors. Fixed and Variable Displacement. Revised 5/99 691

Vickers. Piston Motors. Inline Piston Motors. Fixed and Variable Displacement. Revised 5/99 691 Vickers Piston Motors Inline Piston Motors Fixed and Variable Displacement Revised 5/99 691 Table of Contents Introduction........................................................................................

More information

Note: For use with hydraulic fluids other than those listed above, please consult Yuken representative in advance.

Note: For use with hydraulic fluids other than those listed above, please consult Yuken representative in advance. PRESSURE CONTROLS Fluid Types Any type of hydraulic fluids listed in the table below can be used Petroleum base oil Synthetic Fluids Water Containing Fluids Use equivalent to ISO VG32 or VG46. Use phosphate

More information

Flow volume: l/min Max differential pressure: 16 bar Applications: Lubrication, circulation and transfer

Flow volume: l/min Max differential pressure: 16 bar Applications: Lubrication, circulation and transfer Std Line ACE3 Screwpump Series Product description Flow volume: 15-180 l/min Max differential pressure: 16 bar Applications: Lubrication, circulation and transfer The Std Line (standard) ACE pumps come

More information

Off-line Oil Filter Module Pi 8400

Off-line Oil Filter Module Pi 8400 Off-line Oil Filter Module Pi 8400 Volume flow l/min 1. Features Compact, ready-to connect oil filter module for modern hydraulic and lubrication systems Low noise internal gear pump Minimum loss of performance

More information

Pilot Operated Pressure Relief Valve Series R5V (Denison)

Pilot Operated Pressure Relief Valve Series R5V (Denison) Characteristics Pilot operated pressure relief valves series R5V have a similar design to the subplate mounted R4V series. The SAE flanges allow to mount the valves directly on the outlet flanges of pumps

More information

Gas Pressure Governors

Gas Pressure Governors 7 641 ISO 9001 SKP10... SKP20... SKP13... SKP23... VGG... VGF... VGH... Electrohydraulic Actuators SKP1... Gas Pressure Governors SKP2... Gas Valves VGG... VGF... VGH... On / off safety shut-off valves,

More information

ACG7. Std Line. Product Description. Max differential pressure: 16 bar Circulation, lubrication and transfer ACG GB

ACG7. Std Line. Product Description. Max differential pressure: 16 bar Circulation, lubrication and transfer ACG GB ACG7 Std Line Product Description Flow volume: 80-1200 l/min Max differential pressure: 16 bar Applications: Circulation, lubrication and transfer 1. Applications 1.1 Functionality The Std Line (standard)

More information

Chapter 5: Flow Valves

Chapter 5: Flow Valves Catalogue HY11-300/UK Contents Chapter : Flow Valves Series Description Size Mounting Page Parker Standard DIN / ISO 1/4 3/8 1/2 3/4 1 06 10 16 Throttle valves, manual adjustment MVI -2 NS -4 FS With free

More information

Fixed Displacement Pump A2FO

Fixed Displacement Pump A2FO RE 91401/01.97 Brueninghaus Hydromatik eries 6, for open circuits Axial tapered piston - bent axis design izes 5...1000 Nom. Pressure up to 400 bar Peak Pressure up to 4 bar RE 91401/01.97 replaces 11.95

More information

5.2 MEDIUM HEAVY DUTY SERIES SIZE 3

5.2 MEDIUM HEAVY DUTY SERIES SIZE 3 .2 MEDIUM HEAVY DUTY SERIES SIZE 3 CONTENTS PGI101 Ordering Code.2.1 Medium Heavy Duty Series Technical Information.2.2 Specifications.2.3 Hydraulic fluids.2.4 Viscosity range.2. Temperature range.2.6

More information

Solenoid valve VDHT Standard BSP (British Standard Pipe)

Solenoid valve VDHT Standard BSP (British Standard Pipe) MAKING MODERN LIVING POSSIBLE Data sheet Standard BSP (British Standard Pipe) high-pressurepumps.danfoss.com Contents 1. Picture overview...3 2. Introduction...4 3. VDHT valve selection overview...4 4.

More information

Variable Axial Piston Pump A10V Series - 52/53

Variable Axial Piston Pump A10V Series - 52/53 Variable Axial Piston Pump A10V eries - 52/53 eries 52/53 - Open Circuit Peak Pressure 315 bar (4,600 psi) Nominal Pressure 250 bar (3,600 psi) izes 10cm 3 /rev - 63cm 3 /rev (0.64in 3 /rev-3.8in 3 /rev)

More information

Variable Vane Pump, Direct Controlled PV7...A Series 1X / 2X

Variable Vane Pump, Direct Controlled PV7...A Series 1X / 2X Variable Vane Pump, Direct Controlled PV7...A Series 1X / X RE 1 Issue: 1.13 Replaces: 8.8 Sizes 1 to Maximum pressure 1 bar Displacement volume 1 to cm 3 Features Very short control times Low noise Mounting

More information

SBM TECHNOLOGY Cooling / Air Recovery Valve

SBM TECHNOLOGY Cooling / Air Recovery Valve SBM TECHNOLOGY Cooling / Air Recovery Valve Part no. VSP15203x Advanced high pressure seal technology Integrated non-return valve Robust, compact & lightweight design Proven & reliable technology Maintenance

More information

ACF5. Std Line. Product Description. Max differential pressure: 16 bar Circulation, lubrication and transfer

ACF5. Std Line. Product Description. Max differential pressure: 16 bar Circulation, lubrication and transfer ACF5 Std Line Product Description Flow volume: 310-2900 l/min Max differential pressure: 16 bar Applications: Circulation, lubrication and transfer ALSO VALID FOR PUMP SERIES UCF Generation 5 1. Applications

More information

5/2 and 5/3 Way Valves

5/2 and 5/3 Way Valves Caracteristics to VDI 9 Pressures quoted as gauge pressure Characteristics Symbol Unit Description General Features Ceramic Spool Valve Mounting On base plate, Tube connection Base plate Port size G1/

More information

Rev. E Sept 06. VP300 INSTRUCTION MANUAL Part # DISPENSING VALVE MODEL VP300 INSTRUCTION MANUAL

Rev. E Sept 06. VP300 INSTRUCTION MANUAL Part # DISPENSING VALVE MODEL VP300 INSTRUCTION MANUAL DISPENSING VALVE MODEL VP300 INSTRUCTION MANUAL CONTENTS 1 Introduction page 3 2 Specifications page 3 3 Part Description page 4 4 Operating Principles page 5 5 Operating Procedure 5-1 Setup page 6 5-2

More information

Low Speed High Torque Motors

Low Speed High Torque Motors Low Speed High Torque Motors Catalogue HY29-0503/UK TABLE OF CONTENTS Table of contents Features General information Functional description Technical data 3 4 4 5 6 FRAME SIZE P Operating diagrams Overall

More information

Axial Piston Fixed Pump A17FNO Series 10

Axial Piston Fixed Pump A17FNO Series 10 Axial Piston Fixed Pump A17FNO Series 10 RE 91510 Issue: 06.2012 Replaces: 03.2010 Size 125 Nominal pressure 250 bar Maximum pressure 300 bar For commercial vehicles Open circuit Features Fixed pump with

More information

Axial Piston Variable Pump AA4VG

Axial Piston Variable Pump AA4VG Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service Axial Piston Variable Pump AA4VG RA 92003-A/06.09 1/64 Replaces: 03.09 Data sheet Series 32 Size 28...

More information

Solenoid valve VDHT standard BSP (British Standard Pipe)

Solenoid valve VDHT standard BSP (British Standard Pipe) Technical data sheet standard BSP (British Standard Pipe) danfoss.high-pressurepumps.com 521B1166 / DKCFN.PD.043.A1.02 Index 3. Picture Overview 4. Features 5. Technical data 6. Technical data 7. General

More information

Dial thermometers. Gas filled system and Bi-metal. dial thermometers

Dial thermometers. Gas filled system and Bi-metal. dial thermometers JJ Dial thermometers JJ Diesel engine thermometers JJ Low temperature dial thermometers JJ Remote reading dial thermometers JJ Remote reading diesel engine thermometers JJ Remote reading low temperature

More information

OMEW Hydraulic Motor Versions

OMEW Hydraulic Motor Versions Versions VERSIONS Mounting flange Wheel Shaft Port size European version US version Clockwise shaft rotation (CW version) 1) Counter clockwise shaft rotation (CCW version) 1) Tapered 35 mm G 1 /2 X X X

More information

3.3 VARIABLE DISPLACEMENT MECHANICAL COMPENSATION

3.3 VARIABLE DISPLACEMENT MECHANICAL COMPENSATION . VRIBL ISPLMNT MHNIL OMPNSTION ONTNTS PVV101 Ordering ode..1 Mechanical compensation Technical Information..2 Specifications.. Hydraulic fluids..4 Viscosity range..5 Temperature range..6 Seals..7 Filtration..8

More information

Variable Displacement Motor AA6VM (A6VM)

Variable Displacement Motor AA6VM (A6VM) Variable Displacement otor 6V (6V) Series 6, for open and closed circuits xial tapered piston - bent axis design 5800 psi Sizes 28 1000 Nominal Pressure up to (400 bar) Peak Pressure up to 6500 psi (450

More information

Rexroth Hydraulics. Fixed displacement vane pumps Types PVV and PVQ RE /11.97

Rexroth Hydraulics. Fixed displacement vane pumps Types PVV and PVQ RE /11.97 RE 1 335/1.97 RE 1 335/11.97 Fixed displacement vane pumps Types and Nominal sizes 18 to 193 Series 1X Maximum operating pressure 21 bar Maximum displacement 18 to 193 cm 3 H/A/D 5769/97 Single pump type

More information

Applications. NG 6 according to DIN 24340/ISO 4401 CETOP RP 121 H

Applications. NG 6 according to DIN 24340/ISO 4401 CETOP RP 121 H Seated valves Type WV700 Features Direct operated Leakage free High duty cycle Long lifetime through hardened poppets and valve seats Positive overlap (exceptions see product information) Available as

More information

ATL 12 ACME SCREW LINEAR ACTUATOR OVERALL DIMENSIONS. La =Lc + Stroke Lc T. Rear bracket SP. Stroke. Capacitor

ATL 12 ACME SCREW LINEAR ACTUATOR OVERALL DIMENSIONS. La =Lc + Stroke Lc T. Rear bracket SP. Stroke. Capacitor ACME SCREW LINEAR ACTUATOR Stroke OVERALL DIMENSIONS La =Lc + Stroke Lc T Capacitor Rear bracket SP Pin Standard head with threaded hollow bore BA depth 17 Stroke end reed switches FCM Lenght Stroke 300

More information

HP HYDRAULIC MANUAL OVERRIDE

HP HYDRAULIC MANUAL OVERRIDE HP HYDRAULIC MANUAL OVERRIDE HPA / HPB / HPC / HP1 INSTALLATION AND OPERATION MANUAL CONTENTS SECTION CONTENT PAGE 1 Introduction 2 Overview Installation Operation - Double Acting Operation - Spring Return

More information

«Standard» Hydraulic power unit BM

«Standard» Hydraulic power unit BM «Standard» Hydraulic power unit BM Tank volume V max = 25 l Flow rate Q max = 25,5 l/min Motor power P max = 3 kw CONTENT CHARACTERISTICS...1 DESCRIPTION...1 FUNCTION...1 ENERGY EFFICIENCY...1 KEY DATA

More information

Components for central heating

Components for central heating 01 01 Components for central heating Booster units and spare parts 18 Hydraulic separator and spare parts 21 Dirt separators - Deaerators 23 By-Pass differential valve - Air separator units 32 Filling

More information

Electric Lifting Cylinder TV / KV 5 XE Load up to N

Electric Lifting Cylinder TV / KV 5 XE Load up to N S+R S+R automation systems GmbH Electric Lifting Cylinder TV / KV 5 XE Load up to 6.500 N Lifting Moving Positioning Design and functuion An electric lifting cylinder is an electro-mechanical drive unit.

More information

» Feeding mechanism of robots and manipulators» Metal working machines» Textile machines» Machines for agriculture» Food industries

» Feeding mechanism of robots and manipulators» Metal working machines» Textile machines» Machines for agriculture» Food industries HYDRAULIC HW APPLICATION» Conveyors» Feeding mechanism of robots and manipulators» Metal working machines» Textile machines» Machines for agriculture» Food industries» Grass cutting machinery etc. CONTENTS

More information

Directional Valves for oil or grease

Directional Valves for oil or grease 1-173-EN Directional Valves for oil or grease 161-1-31 161-1-5 DV5-4 Function he directional valves listed on the following pages are used to control the flow of lubricants, e.g. to divide up a central

More information

NTN-SNR HYDRAULIC NUT HMV..EBF OPERATING INSTRUCTIONS

NTN-SNR HYDRAULIC NUT HMV..EBF OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS Copyright NTN-SNR HMV_TS 1964gb1.04 TABLE OF CONTENTS 1. Safety Instructions... 2 2. Product Description... 3 2.1. Structure and equipment... 3 2.2. Connections / Bores... 4 2.3.

More information

RAM Company USA Products Line

RAM Company USA Products Line RAM Company USA Products Line Trunnion Mounted Ball Valves Metal Seated Ball Valve 3-Way Ball Valve Jacket Ball Valve Ball Valves with Actuator Trunnion Mounted Ball Valves Main Features DOUBLE PISTON

More information

Cartridge Valves Technical Information Directional Valves DCV 03

Cartridge Valves Technical Information Directional Valves DCV 03 OVERVIEW DCV 03 directional control valves consist of: housing (1), control spool (5), with two centering springs (4), and cylindrical operating solenoids (2, 3). The three-position directional valves

More information