1 1 of 10 Overview Break Resistant Lens (#-LE) End Cap (#-EC) LED (Included) luminum Extrusion (#) Optics (End View) 33 Power Lead Connected to Remote Driver (Included) (0.5 Minimum Bend Radius) Note: dd 0.18 to overall length of fixture for cordgrip Clear Lens Frosted Lens Semi-Frosted Lens Optic Lens (15, 30, 45, 60 ) symmetric Lens IMPORTNT VERIFY CORRECT LUMINIRE WS RECEIVED WITH CORRECT COLOR TEMPERTURE ND VOLTGE BEFORE CUTTING OR INSTLLING. CLI WILL NOT BE RESPONSIBLE IF INCORRECT LUMINIRE IS INSTLLED. PRODUCT INFORMTION For accent, cove, edge, under cabinet lighting 24 volts DC for easy and safe installation Long life, energy efficient LEDs Can be ordered to specific lengths for easier installation when exact dimensions are known (Example: 10 x 10 6 ) Plug and light system Lead wires are typically 33 long and exit on one end Product is shipped in 8 max luminaires INSTLLTION REMENDTIONS lumleds LED tape must be mechanically attached directly to mounting surface using mounting clips or channels Conduit raceway should be sleeved at one end for low voltage wires going to transformer ELECTRICL lumleds remote drivers (included) are available with 120V or 277V primary voltage and 24VDC secondary voltage Calculate load (Driver / Power Supply) To calculate load, multiply watts per foot by length Example: 4 Watts x 30 = 120 Watts Maximum load per low voltage fixture depends on size of driver Standard Output: 300 Watts driver maximum Mid Output: 100 Watts driver maximum High Output: 100 Watts driver maximum INSTLLTION TOOLS REQUIRED Electric compound miter saw Phillips bits - sufficient quantity 14.4 to 28 volt cordless drill Electrical three ways Drill bits - concrete or wood Measuring tape Electrical cords Chalk line Safety glasses Sharp scissors Marker Soldering iron with kit Electric hammer drill (optional)

2 FETURES PPLICTIONS ccent, Cove, Under Cabinet Lighting PRIMRY VOLTGE 120V or 277V SECONDRY VOLTGE 24VDC LMP TYPE High, Mid, and Standard Output LEDs (No Mercury) LENGTH Built to Order CONSTRUCTION luminum Extrusion MOUNTING Mounting Clips LISTING Dry, Damp, or Wet (IP65 or IP67) Location UL2108, CS C22.2#9 UL8750, CS250 CRI High Output (HO) > 90 Mid Output (MO) > 90 Standard Output (SO) > 85 DIMMING Forward Phase, 0-10V (100% - 10%), 0-10V (100% - 0%) WRNING When using alumleds for any application, basic safety precautions should always be followed to reduce the risk of fire, electric shock, and personal injuries. alumleds must be installed in accordance with the NEC or CEC as applicable. Do not install alumleds in hazardous locations or closer than 6 from any curtain or similar combustible material. alumleds have line voltage risk of shock. Consult factory for any malfunctions. Do not attempt to repair. Use alumleds with specified rated voltages. Do not exceed the specified voltage for any alumleds luminaire. Ensure power is off before installation begins, during replacements, additions, or repairs. Do not cover alumleds as the covering may cause lamps to overheat, melt, or ignite the covering. Do not use alumleds if damaged, such as, broken boards, loose connections, or frayed wire insulation. Inspect before installing. Do not secure alumleds with nails, or like means that might damage the wiring inside. Secure it by using mounting clips. Do not submerge alumleds in liquid. Do not install alumleds on places where it is subject to continuous flexing. Do not mount alumleds inside tanks, or enclosures of any kind. Do not drill holes or break any barrier on alumleds aluminum housing, end caps, or lens covers. Do not use alumleds extrusion as a raceway for additional wire. Non-factory feed-through wires inside alumleds will void warranty. Ground Fault Circuit Interruptor (GFC) protections should be provided on circuits or outlets when alumleds is used for outdoor applications. Surge protector must be set up for electrical power system to avoid damaging alumleds lighting system. 2 of 10 Overview DIMMING PROTOCOL (FORWRD PHSE DIMMING) Technical Requirements For Control Equipment (Forward Phase Dimming) Magnetic Low Voltage (MLV) - Magnetic (core and coil, toroidal) transformer-supplied low voltage lighting. Electrical Characteristics - Inductive Special Requirements - Symmetric cycles (VDC 2), smooth turn off (positive and negative periods are equal for safe MLV transformer operation) Symmetric Forward Phase-Control DIMMING PROTOCOL (0-10V DIMMING) LS50T is available in 120 or 277 volts with a dimmable remote driver. The remote driver is available with 0-10V dimming capabilities. Consult factory for other dimming protocols available. The following applies to 0-10V dimming interfaces. 0-10v fluorescent dimmer will not dim the LEDs. Technical Requirements For Control Equipment The light output of the LEDs operated by the controllable LED driver is controlled by DC voltage applied to the control input leads (grey and violet). The actual response curve of LED driver current versus control voltage. The control device must be capable of accepting, or sinking, the DC current flow from the driver. The DC current from the driver that must be sinked by the control circuit is approximately 150u (+/50% for isolated dim interfaces, up to 1.5m for non-isolated dim interfaces). If the control bus is opened, or if the control device internally opens the control bus under some conditions, the voltage on the control bus will then be a function of the drivers, which is 10-15V. Maximum light output will be delivered under this condition. If the control bus is shorted either by a mechanical switch in the control or by the circuitry of the control device, or inadvertently in the wiring, the current on the control bus will be less than 1.5m. s can be determined from the two items, simple two-level operation of the drivers can be achieved by proper usage and application of a simple open/closed switch on the control bus with maximum light being achieved when the switch is open and minimum light with the switch is closed. The driver is intended to be used with control voltages between 0-10VDC volts peak maximum on the driver control leads. Control equipment intended to control more than one driver must be capable of sinking the current supplied tot the control bus by the maximum number of drivers specified for the control device. t any given level setting it must maintain control bus voltage constant within a range of ±5% as the number of drivers connected to the control bus varies from a minimum of one driver up to the maximum number specified for the control device. Driver of various ratings may be mixed on the same control system.

3 Do not apply excessive pressure to surface of PCB or LEDs 3 of 10 Do not attempt to fold, crease, or twist PCB Product Care Do not overlap extrusions in any way Do not cover PCB with any material TR 1.5 <1.5 Do not install connectors without shrink tube for wet location Do not penetrate PCB with any foreign object 1.5.1mm) <1.5 (<38.1mm) Do not use a lighter to heat shrink tube Do not install wet location in outdoor cove without proper drainage ) Do not overlap PCBs at any location < <1.5 (<38.1mm)

4 1. Measure area where will be installed. REMENDTION: Use chalk line to ensure a straight installation. 4 of 10 Mounting Clips 4c. Screw MC-3 to surface, then snap extrusion into mounting clip Chalk line 2. Mark location where mounting clips will be installed. REMENDTION: Quantity 3 6 of mounting clips = quantity 3 9 of fixture Use a mounting clip at the joint between two fixtures MC-3 3. Lay mounting clips and pre-drill using proper drill bit for surface 3 9 and screw size 2 6 REMENDTION: 8/32 X 1 screw 2.15 X = Specify Length a. Screw MC-1 to surface, then snap extrusion into mounting clip ssembled End View d. Screw MC-2 to surface, then snap extrusion into mounting clip MC ssembled End View -MC-4-X X = Specify Length 4b. Screw MC-2 to surface, then snap extrusion into mounting clip X = Specify Length 1.89 ssembled End View MC ssembled End View X = Specify Length

5 5 of 10 Mounting Fixture (Dry Location) 1. Measure area where will be installed. REMENDTION: Use chalk line to ensure a straight installation. 5. Conduct continuity test. Troubleshoot Good Chalk line 2. Mark location where mounting clips will be installed. REMENDTION: Quantity of mounting clips = quantity of fixture +1. Use a Mounting mounting clip clip at the joint between two fixtures. 3. Lay mounting clips and pre-drill using proper drill bit for surface and screw size. REMENDTION: 8/32 X 1 screw If a conductive path is formed between positive and negative wire, the multimeter will beep. You need to trouble shoot to find the short. See page 7 for troubleshooting guide VDC V If there is no conductive path, the multimeter will not beep. 6. Set voltmeter to DC voltage, then test power source before connecting. Power source 7. Connect power source to power connector. TIP: If LEDs do not turn on, flip polarity (+,-) or power source connection to power connector. TR Power Source DCV DC V DCV DCV DC V VDC V Confirm the correct voltage, depending on the light strip. Power connector 4. Screw mounting clip to surface, then snap extrusion into mounting clips.

6 1. Measure area where will be installed. REMENDTION: Use chalk line to ensure a straight installation of 10 Mounting Fixture (Wet Location) 5. If applicable, slide shrink tube over connectors 1-B1 and apply heat. Shrink tube will shrink down completely to seal the connectors. Shrink tube Chalk line 2. Mark location where mounting clips will be installed. REMENDTION: Quantity of mounting clips = quantity of fixture +1. Use a Mounting mounting clip clip at the joint between two fixtures Lay mounting clips and pre-drill using proper drill bit for surface and screw size. REMENDTION: 8/32 X 1 screw Conduct.75 continuity test..5.5 Troubleshoot.5 pply heat pply silicone to seal connections Sealed connectors Good If a conductive.75 path is formed between positive and negative wire, the multimeter will beep. You need to trouble shoot to find the short. VDC VDC VDC If there is no conductive VDC path, the multimeter will not beep. See page 7 for troubleshooting guide VDC VDC 4. Screw mounting clip to surface, then snap extrusion into mounting clips. 7. Set voltmeter to DC voltage, then test VDC power source before connecting. VDC DCV DCV DC DC DCV Power source V DCV DC V Confirm the correct voltage, depending on the light strip. DCV DC V 8. Connect power source to power connector. TIP: If LEDs do not turn on, flip polarity (+,-) or power source connection to power connector. TR Power Source Power connector

7 7 of 10 Troubleshooting TROUBLESHOOT Do not reset breaker multiple times. If the unit is overloaded the breaker will trip shutting off the transformer and lights. If the breaker reset button has been held down by hand or any type of pressure (example: duct tape), or if the breaker has been reset multiple times without trouble shooting, the unit will: - Burn the transformer bobbin - Burn the thermal or magnetic breaker - Burn the primary or secondary wires due to high amperage caused by overload and/ or short circuit in line which will not allow the breaker to reset - Damage the lighting 1. Turn off power before beginning. Check for any twisting or damage to the circuit in the LED lightstrip. If there is excessive damage and circuit is broken, the lightstrip must be replaced. Torn lightstrip Damaged lightstrip 2. Check for metal particles or other foreign objects causing the short. Foreign object Metal flakes 3. Check if cut is clean and not frayed, causing positive and negative copper pads to touch. Frayed end

8 8 of 10 Surge Protector CSE DIMENSIONS 2X ø SURGE PROTECTOR SPECIFICTIONS MODEL INPUT VOLTGE SURGE PROTECTION LEVEL MOUNTING ENCLOSURE MTERIL INPUT LEDS INPUT FREQUENCY LS-SP V 10kV, 10k, NSI C62.41 Catergory C SnapLOCK/ Footed Polycarbonate 6, 18WG stranded 105 Degrees C stripped 3/8 tinned 60Hz PRODUCT FETURES The Surge Series are 3-leaded devices that protect Line-Ground, Line- Neutral, and Neutral-Ground in accordance with IEEE / NSI C guidelines. Protects against surges according to IE EE C C High (10k and 10kV). Surge current rating = 10,000 mps using industry standard 8/20 µsec wave. Surge Location Rated Category C3. UL Recognized Component in the United States and Canada (UL1449). Type 4 Surge Protection Device. High temperature, flame retardant plastic enclosure, 85 C maximum surface temperature rating. Thermally Protected Transient Over-voltage Circuit. WIRING DIGRM V(in)B Black Green Black Surge White Com Ground LOD LED Driver, or Lighting PRODUCT SPECIFICTIONS The Surge series of products are designed to be used in conjunction with LED Drivers and fixtures to provide an additional level of protection against powerline disturbances in industrial, commercial and residential applications where surge protection to IEEE C is required.

9 9 of 10 Transformer WTTS () PER CIRCUIT (Maximum wire length to prevent voltage drop) WIRE SIZE VOLTGE G 12V G 24V G 12V G 24V G 12V G 24V G 12V G 24V TRNSFORMER CRE Do not submerge transformer in any liquid Do not leave any exposed wires Do not cover transformer without proper ventilation Do not install damaged transformer MGNETIC LOW-VOLTGE DIMMER RTINGS The stated (volt-ampere) rating is the rated capacity of the dimmer which includes the magnetic transformer heat losses and the lamp load. transformer dissipates less than 20% of the connected load as heat. dded together,the lamp load and the transformer loss determine the dimmer capacity required. See the example below. 600 Power to transformer and power through dimmer 120W Heat Transformer Losses (UL limit: 80% efficient) 480W Lamp load

10 10 of 10 Maintenance CLENING MTERILS The use of solvents and/or cleaners which are not compatible with polycarbonate will result in the softening, crazing, and/or cracking of the plastic part. This is especially true of polycarbonate lamps and mounting bases which may be under stress in their normal applications. PTIBLE WITH POLYCRBONTE: Mild soap and water Mineral Spirits Isobutyl alcohol VM and P Naphtha Varsol No.2 Mexane Freone TF and TE-35 Ethanol Dirtex 2% Sol. Reg. Joy 10% Sol Bon mi White Kerosene Methyl alcohol Heptane Petroleum Ether/65 degrees C Isopropyl alcohol Lacryl PCL-2035 polycarbonate cleaner NOT PTIBLE WITH POLYCRBONTE: Trichlor Gasoline ll Liquid Detergents cetone Carbon Tetrachloride Pink Lux (Phosphate free) Triclene Chlorinated Hydrocarbons #1 & #3 denatured alcohol Methyl Ethyl Keytone (MEK) Texize-8006, 8129, 8758 MIBK Liquid Cleaner 8211 Toluol gitene Benzol jax Kleenol Plastics Lysol Stanisol Naphtha Oils Lemon Joy (phosphate free) Diversol Lestoil

Installation Instructions. Power Connector. Electrical cords .75 CALIFORNIA ACCENT LIGHTING, INC.

Installation Instructions. Power Connector. Electrical cords .75 CALIFORNIA ACCENT LIGHTING, INC. 1 of 11 Overview 6.5 3.9 or 6.5 Power Connector 6.5 increments up to max (#LLED8200-PC) run ± 0.125 cutting tolerance LED StripLite 6.5 (2.5W) or 3.9 (5.5W) increments up to max run (#LLED8200) ± 0.125

More information

lipleds LLED8050-LWR 1 of 8 Installation Instructions

lipleds LLED8050-LWR 1 of 8 Installation Instructions lipleds LLED8050-LWR 1 of 8 Overview Frosted Lens Cover (#LLED8050-LWR-LF) LED StripLite (#LLED8050) Power Connector (#LLED8050-PC) End View 1.45.50.44 Extrusion (#LLED8050-LWR) 1.15 2 8 Maximum extrusion

More information

Installation Instructions

Installation Instructions treelite TRL3000 1 of 8 Overview Power Connector w/ Housing (#TRL3000-PCH) (Not Included) Clear Caps (#TRL3000-CC) (Included) LED Lamp (Included) Custom Green Socket (Included) 1.0 End View Green StripLite

More information

Installation Instructions. Electrical cords

Installation Instructions. Electrical cords 1 of 12 Overview Break Resistant Lens (#LLED8200-RC-LC) Power Connector (#LLED8200-PC) End View 1.13 Extrusion (#LLED8200-RC) 1.25 End Cap (#LLED8200-RC-EC) 1.51 8 Maximum extrusion and lens length (Dry

More information

Installation Instructions W, 4W End View (WET) ± cutting tolerance (Example: 2W x 22.5 = 45W) 6

Installation Instructions W, 4W End View (WET) ± cutting tolerance (Example: 2W x 22.5 = 45W) 6 1 of 12 Overview Surface Mount LEDs (Included) 6.5 3.9 or 6.5 Modular LED Strip (#) Replaceable Modules 6.5 2 6.5 (2.5W) or 3.9 (5.5W) increments up to max run ± 0.125 cutting tolerance Mounting Clip (#-MC)

More information

Installation Instructions

Installation Instructions 1 of 11 Overview Break Resistant Lens (#LE) 0.45 Feed Points Bottom Feed (BF) End Cap (#EC) 6 Power Lead (3.5 min. bend radius WET) (1.5 min. bend radius DRY) LED (Included) luminum Extrusion (#) dd the

More information

Installation Instructions. Power Connector (#LLED9100-F-PC-180D)

Installation Instructions. Power Connector (#LLED9100-F-PC-180D) 1 of 10 Overview End Cap U-Channel (#-UC) Mounting Clip (#-MC) End View 0.84 Flexible 0.44 Power Connector (#-PC-180D) IMPORTNT VERIFY CORRECT LUMINIRE WS RECEIVED WITH CORRECT COLOR TEMPERTURE ND VOLTGE

More information

lipleds LLED8050-LSR 1 of 9 Installation Instructions

lipleds LLED8050-LSR 1 of 9 Installation Instructions lipleds LLED8050-LSR 1 of 9 Overview Canopy (#LLED8050-CN-XX) ircraft Cable (#LLED8050-LSR-C) Power Connector (#LLED8050-LSR-PC) Specify Length (Max. 300 ) Extrusion (#LLED8050-LSR) End View.96 LED StripLite

More information

Installation Instructions. Striplite (#STL6500-STL) Utility knife

Installation Instructions. Striplite (#STL6500-STL) Utility knife 1 of 10 Overview Striplite (#-STL) Clear Lens (#-CL) End View 2.50 1.90 Aluminum Step Extrusion (#) IMPORTANT VERIFY CORRECT LUMINAIRE WAS RECEIVED WITH CORRECT COLOR TEMPERATURE AND VOLTAGE BEFORE CUTTING

More information

Installation Instructions. Electrical cords CALIFORNIA ACCENT LIGHTING, INC.

Installation Instructions. Electrical cords CALIFORNIA ACCENT LIGHTING, INC. 1 of 10 Overview Frosted Lens Cover (#-LF) Power Connector (#LLED8000-PC) LED StripLite (#LLED8000) 6.5 6.5 increments up to max run End View.80.75.78 3.9 or 6.5 6.5 3.9 or 6.5 3.95 3.95 6.5 (2.5W) or

More information

LLED8100-LSR. Overview. Installation Instructions

LLED8100-LSR. Overview. Installation Instructions 6.5 increments up to max run ± 0.125 cutting tolerance *See max run for more information 6.5 (2.5W) or 3.9 (5.5W) increments up to max run ± 0.125 cutting tolerance *See max run for more information 1

More information

ALS600T. Overview. Dimming Protocol (0-10V: 0% Dimming)

ALS600T. Overview. Dimming Protocol (0-10V: 0% Dimming) Page 1 of 10 Overview Louver (Optional) (ALS600TLVR) Important Notice: Verify correct luminaire was received with correct color temperature and voltage before cutting or installing. CALI will not be responsible

More information

Installation Instructions

Installation Instructions 1 of 12 Overview Clear Lens Cover (#-LC) Power Connector (#LLED8500-PC) RGB StripLite (#LLED8500) End View.73 Extrusion (#) 1.62 End Cap (#-EC) 8 Maximum extrusion and lens length (Dry Location field cuttable)

More information

Installation Instructions. Power Connector (#LLED8300-PC) End View Electrical cords

Installation Instructions. Power Connector (#LLED8300-PC) End View Electrical cords 1 of 13 Overview Frosted Lens Cover (#-LF) LED StripLite (#LLED8300) Power Connector (#LLED8300-PC) End View.73 Extrusion (#) 1.62 End Cap (#-EC) 8 Maximum extrusion and lens length (Dry Location field

More information

Installation Instructions .50. Utility knife

Installation Instructions .50. Utility knife 1 of 17 Overview Replacable LED luminum Step Extrusion (#) Clear Lens (#-CL) Striplight Top Light (#-STL).50 End View 2.83 Clear Lens (#-CL) Striplight Bottom Light (#-STL).86 IMPORTNT VERIFY CORRECT LUMINIRE

More information

lipleds LLED8650-LW 2 of 12 Installation Instructions

lipleds LLED8650-LW 2 of 12 Installation Instructions lipleds LLED8650-LW 1 of 12 Overview Frosted Lens Cover (#LLED8650-LW-FL) RGBW StripLite (#LLED8650) Power Connector (#LLED8650-PC) End View.50 Extrusion (#LLED8650-LW) 1.15 8 Maximum extrusion and lens

More information

Installation Instructions .59 CALIFORNIA ACCENT LIGHTING, INC.

Installation Instructions .59 CALIFORNIA ACCENT LIGHTING, INC. 1 of 13 Overview Frosted Lens Cover (#-LF) Power Connector (#LLED8300-PC) LED StripLite (#LLED8300).80 6.5 3.9 or 6.5 6.5 increments up to max run ± 0.125 cutting tolerance Extrusion (#).59 6.5 (2.5W)

More information

marketlite ML2000-CAH 1 of 11 Installation Instructions

marketlite ML2000-CAH 1 of 11 Installation Instructions marketlite ML2000-CAH 1 of 11 Overview Aircraft Hook (Included) End Cap (#ML2000-EC) 12 Gauge Stranded Black Conductor Socket Detail Strain Relief Cable (Included) 6.30 LED Lamp (Included) Power Plug (#ML2000-PP)

More information

marketlite ML2000-CB 1 of 11 Installation Instructions

marketlite ML2000-CB 1 of 11 Installation Instructions 1 of 11 Overview Aircraft Hook (Included) End Cap (#ML2000-EC) 12 Gauge Stranded Black Conductor Socket Detail Strain Relief Aircraft Cable (Included) 4.38 Power Plug (#ML2000-PP) Canopy CB (Included)

More information

Installation Instructions

Installation Instructions 1 of 12 Neon LEDs (#) Overview Mounting Channel (#-UC) End Cap (#-EC) Mounting Clip (#-MC) END VIEW END VIEW 0.64 1.06 Neon LED (#) 5 4 Minimum Bend Radius Power Connect (#-PC-4mp-120V) 1. 4. MOUNTING

More information

alumleds ALS500T-SQ 1 of 13 Installation Instructions

alumleds ALS500T-SQ 1 of 13 Installation Instructions 1 of 13 Overview (#-CN) (#-PC) (#-C) End View 1.87 Specify Length (Max. 300 ) Removable Bottom Cap (#-BC) 3.44 End Cap (#-EC) Break Resistant Lens (#-LE) LED (Included) luminum Extrusion (#) IMPORTNT VERIFY

More information

Input Voltage: AC: VAC HC: VAC (50/60Hz) Electrical Ratings: WIDE FROSTED MODEL

Input Voltage: AC: VAC HC: VAC (50/60Hz) Electrical Ratings: WIDE FROSTED MODEL WLL MOUNT INSTLLTION E477827 E477829 PPLICTION RS luminaires are designed for use in hazardous locations, indoors, outdoors, wet location, and areas containing moisture, dirt, corrosion, vibration, and

More information

INSTALLATION INSTRUCTIONS WHITE / SINGLE COLOR 24V LED TAPE

INSTALLATION INSTRUCTIONS WHITE / SINGLE COLOR 24V LED TAPE LLI-L1.5W LLI-L2.2W LLI-L2.5W LLI-L3.5W LLI-L4.4W LLI-LHE3.5W LLI-LHE4.4W LLI-LHE5.9W LLI-LTP2.5W LLI-LTP5.0W LLI-LSE3.0W LLI-LWF5.5W LLI-LC4.4W **DANGER: Prior to installation, disconnect power at the

More information

Installation Instructions for SINGLE COLOR 12V or 24V LINEAR LED

Installation Instructions for SINGLE COLOR 12V or 24V LINEAR LED Installation Instructions for SINGLE COLOR 12V or 24V LINEAR LED LLI-L1.5W (T300) LLI-L2.2W (TSHL2835-300) LLI-L2.5W (TSHL2835-600-2.5W) LLI-3.5W (TSHL2835-480) LLI-L4.4W (TSHL2835-600) LLI-L5.9W (TUB5630-560)

More information

24 Volt Eco Flex LED Neon Part Numbers: LFN-2700K, LFN-5800K

24 Volt Eco Flex LED Neon Part Numbers: LFN-2700K, LFN-5800K 24 Volt Eco Flex LED Neon Part Numbers: LFN-2700K, LFN-5800K 11235 West Bernardo Court, Suite 102 San Diego, CA 92127 888-880-1880 Fax: 707-281-0567 EnvironmentalLights.com Eco Flex LED Neon is an adaptable

More information

channel damage the internal components and the weight may break the internal wiring or flexible strip.

channel damage the internal components and the weight may break the internal wiring or flexible strip. YOU MAY NEED End cap Power adaptor Connector pin Splicing pin Connector Silicone glue Pliers Power converter Converter + surge protector Heat shrink Aluminium channel Heat gun NT cutter IMPORTANT NOTES

More information

SLIMFLEX LED Tape Lighting

SLIMFLEX LED Tape Lighting 1 SLIMFLEX LED Tape Lighting Installation Guide BEFORE YOU BEGIN, READ INSTALLATION INSTRUCTIONS THOROUGHLY Install in accordance with the National Electric Code and local regulations This product is intended

More information

MONORAIL KITS INSTALLATION INSTRUCTIONS PENDANTS

MONORAIL KITS INSTALLATION INSTRUCTIONS PENDANTS MONORAIL KITS PENDANTS JESCO Lighting Group is a UL and ETL listed company Copyright 2011 JESCO Lighting Group. All rights reserved. IMPORTANT SAFETY INSTRUCTIONS Be sure to read and unsderstand the following

More information

WARNING. This product uses High Brightness LEDs. Direct viewing of the SMD LEDs at close range should be avoided. Keep product away from children.

WARNING. This product uses High Brightness LEDs. Direct viewing of the SMD LEDs at close range should be avoided. Keep product away from children. WARNING Before use please remove the LED Tape from its bag and allow the odour to dissipate in an unused room or outdoor building. Wash Hands after handling. This product uses High Brightness LEDs. Direct

More information

INSTALLATION INSTRUCTIONS RECESSED EXTRUSIONS WITH LED TAPE

INSTALLATION INSTRUCTIONS RECESSED EXTRUSIONS WITH LED TAPE LLI-XR-CRV LLI-XR-ELF LLI-XR-IFL LLI-XR-IGR LLI-XR-SQF LLI-XR-THF **DANGER: Prior to installation, disconnect power at the source.** Make sure you have all components listed below: LED tape 24VDC Power

More information

OutdoorXUPS-600AHV-8364

OutdoorXUPS-600AHV-8364 OutdoorXUPS-600AHV-8364 TSi Power s OutdoorXUPS-600AHV-8364 provides secure and uninterrupted 230 vac power to critical loads. 1) Weather-tight metal cabinet (IP44 or NEMA 3R rated) 2) 2A and 2B are wide

More information

DL-FLEX (-UP, -UP-HO, -UP-ULTRA)

DL-FLEX (-UP, -UP-HO, -UP-ULTRA) -HO -ULTRA DESCRIPTION DL-FLEX series is a unique commercial grade modular lighting system featuring 3 levels of light output with a wide range of accessories and a variety of control options. This unique

More information

LED NEON FLEX INSTALLATI ON GUI DE

LED NEON FLEX INSTALLATI ON GUI DE LED NEON FLEX INSTALLATI ON GUI DE F I R E F L Y L I G H T I N G. C O M. A U WHAT IS LED NEON FLEX? THE MOST VERSATILE AND SIMPLE LIGHTING SYSTEM YOU WILL EVER USE LED Neon Flex is a green friendly, safe,

More information

IVR15-SPI Solid State Illuminated Rail 2 Post Integral Power Supply

IVR15-SPI Solid State Illuminated Rail 2 Post Integral Power Supply IVR15-SPI - 1.5 Solid State Illuminated Rail 2 Post Integral Power Supply 1.50 recognized 0.3 90 PERTURE Ends of Illuminated rail field cuttable to a minimum of 2 1/8 in length. Illuminated rail is available

More information

NOVA FLEX FLEXIBLE LED SOLUTIONS

NOVA FLEX FLEXIBLE LED SOLUTIONS DESIGN SERIES / ARCHITECTURAL LIGHTING HighCRI (90) LED ribbon light in output ranges for every application. Architecturalgrade lighting that ensures proper execution of design intentions. 50,000 DESIGN

More information

DURATAPE TM ES IP66 OUTDOOR

DURATAPE TM ES IP66 OUTDOOR Key Features Energy efficient narrow spaced LED flexible linear light strip for continuous consistant color in linear applications. Ideal for IP66 exterior cove, under-counter/cabinet, lighting accents.

More information

MONORAIL KITS INSTALLATION INSTRUCTIONS SPOTS

MONORAIL KITS INSTALLATION INSTRUCTIONS SPOTS MONORAIL KITS INSTALLATION INSTRUCTIONS SPOTS JESCO Lighting Group is a UL and ETL listed company Copyright 2011 JESCO Lighting Group. All rights reserved. IMPORTANT SAFETY INSTRUCTIONS Be sure to read

More information

LEDneon flex. Features & Benefits DOT-FREE ILLUMINATION

LEDneon flex. Features & Benefits DOT-FREE ILLUMINATION DOT-FREE ILLUMINATION Features & Benefits Viable alternative to glass neon 220V with power converter 12V DC with constant voltage driver Seamless, dot-free illumination Up to 80% more energy efficient

More information

ROPE LIGHT ITEM # MODEL #UCL48L. Français p. 8. Español p. 15 ATTACH YOUR RECEIPT HERE. Purchase Date

ROPE LIGHT ITEM # MODEL #UCL48L. Français p. 8. Español p. 15 ATTACH YOUR RECEIPT HERE. Purchase Date ITEM #0879887 ROPE LIGHT MODEL #UCL48L Français p. 8 Español p. 15 TTCH YOUR RECEIPT HERE E237798 Purchase Date Questions, problems, missing parts? efore returning to your retailer, call our customer service

More information

DURATAPE TM ES IP66 OUTDOOR

DURATAPE TM ES IP66 OUTDOOR Key Features Energy efficient narrow spaced LED flexible linear light strip for continuous consistant color in linear applications. Ideal for IP66 exterior cove, under-counter/cabinet, lighting accents.

More information

Nuheat WEATHER-READY HEAT TRACE PIPE FREEZE PROTECTION SYSTEM. Self-Regulating Heating Cable Installation Guide. UV Resistant Polyolefin Outer Jacket

Nuheat WEATHER-READY HEAT TRACE PIPE FREEZE PROTECTION SYSTEM. Self-Regulating Heating Cable Installation Guide. UV Resistant Polyolefin Outer Jacket Nuheat WEATHER-READY HEAT TRACE PIPE FREEZE PROTECTION SYSTEM Self-Regulating Heating Cable Installation Guide Tinned Copper Braid UV Resistant Polyolefin Outer Jacket 16 AWG Bus Wire Polyolefin Inner

More information

RibbonFlex Pro LED Accent Lighting White LED Tape Light. Welcome to RibbonFlex Pro LED Tape Lighting. Notes:

RibbonFlex Pro LED Accent Lighting White LED Tape Light. Welcome to RibbonFlex Pro LED Tape Lighting. Notes: RibbonFlex Pro LED Accent Lighting White LED Tape Light 30 White LEDs per meter (9 LEDs per foot) Model # RF3528030 rev 01.14 Welcome to RibbonFlex Pro LED Tape Lighting Ultra thin and flexible, RibbonFlex

More information

Generator Fire Safety: Generator assemblies should be located outside the building.

Generator Fire Safety: Generator assemblies should be located outside the building. SECTION 33 70 00 - ELECTRICAL DISTRIBUTION PACKAGED GENERATOR ASSEMBLIES Generator Fire Safety: Generator assemblies should be located outside the building. All fuel piping from the outside of the building

More information

INSTALLATION INSTRUCTIONS NEON RGB

INSTALLATION INSTRUCTIONS NEON RGB LLI-NCC3.7W **DANGER: Prior to installation, disconnect power at the source.** Make sure you have all components listed below: Neon 24V Non-Diming Power Supply RGB Receiver/Decoder Mounting Clips or Extrusion

More information

OPTIMAX RADIANT FIELD RETROFIT INSTRUCTIONS

OPTIMAX RADIANT FIELD RETROFIT INSTRUCTIONS OPTIMAX RADIANT FIELD RETROFIT INSTRUCTIONS 99-24283-I001 Table of Contents 1. 24V LED Approved Drivers 5 1.1. 24V LED Driver (60-19910-0002).. 5 2. Optimax Radiant 24V LED Lighting. 6 2.1. OP30 6 2.2.

More information

RECESSED TRACK (120V) SPECIFICATIONS

RECESSED TRACK (120V) SPECIFICATIONS RECESSED TRACK (120V) SPECIFICATIONS GENERAL Recessed track shall be approved by the NEC for flush-mounting into ceiling or any flat surface. Recessed Track shall allow fixtures to be easily focused, switched,

More information

DURATAPE TM HO INDOOR RGB+W

DURATAPE TM HO INDOOR RGB+W PROJECT MODEL(S) TYPE High Output RGB+W Tapelight High output indoor RGB and RGB+W LED Tapelight strip emits sharp, color changing effects in indoor niche, cove and architectural decorative applications.

More information

A-BEAM LIGHT. Instruction & Safety Information. Design by Thomas Housden. Dimensions L1600/1800mm H77mm, W51mm. Weight 9-10 KG

A-BEAM LIGHT. Instruction & Safety Information. Design by Thomas Housden. Dimensions L1600/1800mm H77mm, W51mm. Weight 9-10 KG 2017 Design by Thomas Housden A-BEAM LIGHT Dimensions L1600/1800mm H77mm, W51mm Weight 9-10 KG Lamp Type 12V DC LED 20W per metre 1284-1345 lumen per metre 2700K or 3000K colour temp IP40 Hand & Eye Studio

More information

Installation Instructions: HYPERION R-Lite SYSTEM

Installation Instructions: HYPERION R-Lite SYSTEM Installation Instructions: HYPERION R-Lite SYSTEM READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS WILL VOID YOUR WARRANTY! INSTALLATION TIPS Read

More information

OWNER S MANUAL. Please read installation and operation instruction before using this Power inverter.

OWNER S MANUAL. Please read installation and operation instruction before using this Power inverter. OWNER S MANUAL DP AUDIO Model No. DN350 12 Volt DC to 115 Volt AC 150 WATT 300WATT HIGH SURGE POWER INVERTER Please read installation and operation instruction before using this Power inverter. Contents

More information

Plexineon Installation Manual

Plexineon Installation Manual Plexineon Installation Manual ilight Technologies, Inc. 118 South Clinton, Suite 370 Chicago, IL. 60661, USA Tel: 312.876.8630 Fax: 312.876.8631 support@ilight-tech.com www.ilight-tech.com www.ilight-tech.com

More information

DURATAPE TM HO INDOOR

DURATAPE TM HO INDOOR PROJECT MODEL(S) TYPE DURATAPE TM HO High Output LED Tapelight Energy Efficient LED flexible linear light strip for continuous consistent color in linear applications. Extremely flexible and adjustable

More information

Outdoor Installation Using an Electronic LED Power Supply (TE-60L-12)

Outdoor Installation Using an Electronic LED Power Supply (TE-60L-12) 0 Edge Lighting. All Rights Reserved. 78 W. Fullerton Ave Chicago, IL 606 Tel: 77-770-9 Fax: 77-9-6 www.edgelighting.com info@edgelighting.com Installation Instructions for Port Round & Square LED PORT-RD-ST-SA

More information

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION Medium Voltage Standby non-paralleling Control 1. GENERAL GUIDE FORM SPECIFICATION A. The requirements of the contract, Division 1, and part 16 apply to work in this section. 1.01 SECTIONS INCLUDE A. Medium

More information

Installation Manual. CS9300 Professional Series Landscape Lighting System

Installation Manual. CS9300 Professional Series Landscape Lighting System Installation Manual CS9300 Professional Series Landscape Lighting System CS9300 Professional Series Landscape Lighting System pg. 1 READ THESE INSTRUCTIONS ENTIRELY BEFORE BEGINNING INSTALLATION! Congratulations

More information

HPNLS-HO. Installation Manual

HPNLS-HO. Installation Manual Installation Manual WARNING: Do not lift fixture by cables. This could result in permanent damage to both the fixture and the cables. Damage resulting from grasping cables and/or putting undue pressure

More information

Installation Instructions for SINGLE COLOR 24V LINEAR LED NEON

Installation Instructions for SINGLE COLOR 24V LINEAR LED NEON Installation Instructions for SINGLE COLOR 24V LINEAR LED NEON LLI-N2.9W Prior to installation, please confirm that you have the required system components listed below. LED Neon Flow Extrusions/Lens (Optional)

More information

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B Users Manual Defender 1 8.0KW to 14.0KW Online Lighting Inverter Technical Manual #018-0102-01 Revision B Phone: 1.877.DSPM.POWER 1.877.377.6769 Fax: 909.930.3335 Website: www.dspmanufacturing.com E-Mail:

More information

Users Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B

Users Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B Users Manual Cobra Plus Stand-By Lighting Inverter Technical Manual #018-0110-01 Revision B Phone: 1.877.DSPM.POWER 1.877.377.6769 Fax: 909.930.3335 Website: www.dspmanufacturing.com E-Mail: techsupport@dspmanufacturing.com

More information

R820 REV2 SERIES SCR POWER CONTROLS NOVEMBER 2017

R820 REV2 SERIES SCR POWER CONTROLS NOVEMBER 2017 R80 REV SERIES SCR POWER CONTROLS NOVEMBER 017 Product overview The Viconics R80 series SCR power controls are designed for cost effective, precise modulation of electric loads for most electric heating

More information

User Manual. Solar Charge Controller 3KW

User Manual. Solar Charge Controller 3KW User Manual Solar Charge Controller 3KW 1 CONTENTS 1 ABOUT THIS MANUAL... 3 1.1 Purpose... 3 1.2 Scope... 3 1.3 SAFETY INSTRUCTIONS... 3 2 INTRODUCTION... 4 2.1 Features... 4 2.2 Product Overview... 5

More information

Luminaires - LED High Bay

Luminaires - LED High Bay 80 LED High Bay With STANDARD s high bay line, it is now easy to modernize your commercial or industrial applications; it is the perfect alternative for your traditional lighting system. Our high efficacy

More information

LED FLEXIBLE LINEAR DL-FLEX-UP STATIC SERIES DL-FLEX-UP

LED FLEXIBLE LINEAR DL-FLEX-UP STATIC SERIES DL-FLEX-UP LED FLEXIBLE LINEAR UP STATIC SERIES UP DESCRIPTION UP is a commercial grade modular lighting system featuring a wide range of plug-together accessories and a variety of control options. This unique feature

More information

DURATAPE TM SB OUTDOOR

DURATAPE TM SB OUTDOOR PROJECT MOEL(S) TYPE URTPE TM SB Standard spacing SB Tapelight Energy Efficient outdoor IP66 LE flexible linear light strip for continuous consistent color in linear applications. Extremely flexible and

More information

NSGV PT-1000 PORTABLE WELDING STATION I, O & M MANUAL

NSGV PT-1000 PORTABLE WELDING STATION I, O & M MANUAL APPLICATION OF DUST CONTROL EQUIPMENT: CAUTION - Warning Improper operation of dust control system may contribute to conditions in the work area or facility that could result in severe personal injury

More information

INSTALLATION. **Microprocessor Status LED:

INSTALLATION. **Microprocessor Status LED: INSTALLATION VANTAGECONTROLS.COM VANTAGE INSTALL GUIDES 1061 South 800 East Orem, Utah 84097 Telephone 801 229 2800 Fax 801 224 0355 Standard Dimmer Module MODEL: SDM12-EM Overview The SDM12 dimmer module

More information

INSTALLATION INSTRUCTIONS For Light*Waves Flex II Kit with 300-Watt remote transformer

INSTALLATION INSTRUCTIONS For Light*Waves Flex II Kit with 300-Watt remote transformer IMPORTANT SAFETY INSTRUCTIONS READ ALL OF THESE BEFORE INSTALLING THE TRACK SYSTEM. SAVE THESE INSTRUCTIONS AND REFER TO THEM WHEN ADDITIONS TO OR CHANGES TO THE SYSTEM ARE MADE. THIS IS A 12-VOLT SYSTEM

More information

SURFACE TRACK (120/250V) SPECIFICATIONS

SURFACE TRACK (120/250V) SPECIFICATIONS SURFACE TRACK (120/250V) SPECIFICATIONS GENERAL Lighting Track shall allow fixtures to be located anywhere along the track length. Fixtures shall be easily focused, switched, dimmed, accessorized and removed

More information

Battery Power Inverters

Battery Power Inverters Battery Power Inverters Renogy 500W 1000W 2000W Pure Sine Wave Inverter Manual 2775 E. Philadelphia St., Ontario, CA 91761 1-800-330-8678 1 Version 1.4 Important Safety Instructions Please save these instructions.

More information

NUTP7-LED (Amber Finish) NUTP7-WLED (White Finish) 24V LED Tape Light Roll. Source: 24W Watts Per Foot CRI. 24V LED Tape Light Roll

NUTP7-LED (Amber Finish) NUTP7-WLED (White Finish) 24V LED Tape Light Roll. Source: 24W Watts Per Foot CRI. 24V LED Tape Light Roll ILLUMINATING THE FUTURE...SINCE 1989 NUTP7-LED (Amber Finish) NUTP7-WLED (White Finish) 24V LED Tape Light Roll PRODUCT DESCRIPTION Nora s very low profile, energy efficient LED tape is only 7/16" wide

More information

DURATAPE TM HO INDOOR RGB+W

DURATAPE TM HO INDOOR RGB+W PROJECT MODEL(S) TYPE DURATAPE TM HO High Output RGB+W Tapelight High output indoor RGB and RGB+W LED Tapelight strip emits sharp, color changing effects in indoor niche, cove and architectural decorative

More information

M-3025CB-AV Fuel Pump

M-3025CB-AV Fuel Pump SAVE THESE INSTRUCTIONS M-3025CB-AV Fuel Pump Owner s Manual TABLE OF CONTENTS General Information... 2 Safety Instructions... 2 Installation... 3 Operation... 4 Maintenance... 4 Repair... 5 Troubleshooting...

More information

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse-SS Power Pedestals

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse-SS Power Pedestals Lighthouse-SS Power Pedestal Dimensions Height: 44.00" (1117.60 mm) Width: 9.565" (242.95 mm) Depth: 9.875" (250.83 mm) Lighthouse-SS Base Diagram Ø0.50" MOUNTING HOLE (TYP.) 9.5625" 8.0625" 7.3125" C:\Documents

More information

Installation Manual CS9300-LED. Professional Series Landscape Lighting System

Installation Manual CS9300-LED. Professional Series Landscape Lighting System Installation Manual CS9300-LED Professional Series Landscape Lighting System CS9300 Professional Series LED Landscape Lighting System pg. 1 READ THESE INSTRUCTIONS ENTIRELY BEFORE BEGINNING INSTALLATION!

More information

Models beginning with MO, MK, 7B, 6S, 6F or 5B. Product Description. Technical Specifications. Installation Instructions.

Models beginning with MO, MK, 7B, 6S, 6F or 5B. Product Description. Technical Specifications. Installation Instructions. Models beginning with MO, MK, 7B, 6S, 6F or 5B The Mini Meter Product Description Technical Specifications Installation Instructions February 28 th, 2013 1. Product Description...2 1.1 General Description...2

More information

poollux Power plx-pw60 & plx-pw100

poollux Power plx-pw60 & plx-pw100 poollux Power plx-pw60 & plx-pw100 ETL LISTED Conforms to UL STD 379; Certifi.ed.to.CSA.STD.C22.2.#218.1 5005508 Installation Instructions Read all instructions before attempting to perform installation

More information

DURATAPE TM ES OUTDOOR

DURATAPE TM ES OUTDOOR PROJECT MOEL(S) TYPE URTPE TM ES OUTOOR Narrow spacing ES Tapelight Energy Efficient outdoor IP66 LE flexible linear light strip for continuous consistent color in linear applications. Extremely flexible

More information

55 Watt K Triple Series DC/DC Converters

55 Watt K Triple Series DC/DC Converters Features Very Low Noise, < mv P-P Maximum PCB Mounting with Optional Heat Sink or Chassis Mount Versions Efficiencies to 87 Common and Differential Mode Input Filtering Remote Sense On + Volt Output Single

More information

Pole Mount COD Installations (PMCOD)

Pole Mount COD Installations (PMCOD) FLASHRIGHT Display Installation Instructions Pole Mount COD Installations (PMCOD) Delphi (Key needed in some cases) FlashRight Displays 3482 Keith Bridge Rd. Suite # 260 Cumming, GA 30041 Tel. 678-455-9121

More information

diode led 24VDC MAGNETIC DIMMABLE DRIVER SPECIFICATION SHEET 24VDC OVERVIEW FEATURES

diode led 24VDC MAGNETIC DIMMABLE DRIVER SPECIFICATION SHEET 24VDC OVERVIEW FEATURES diode led a division of elemental LED 24VDC MAGNETIC DIMMABLE DRIVER 24VDC WET LOCATION DIMMABLE SPECIFICATION SHEET OVERVIEW 24VDC Magnetic Dimmable Drivers are perfect for supplying low voltage power

More information

HOME CHARGER MODE 2. Series to /32A single phase CONTENTS. Manual IMPORTANT SAFETY INSTRUCTIONS 3 SAFETY INFORMATION 4 INSTALLATION 5

HOME CHARGER MODE 2. Series to /32A single phase CONTENTS. Manual IMPORTANT SAFETY INSTRUCTIONS 3 SAFETY INFORMATION 4 INSTALLATION 5 CONTENTS IMPORTANT SAFETY INSTRUCTIONS 3 SAFETY INFORMATION 4 INSTALLATION 5 OPERATION 8 SPECIFICATIONS 8 MAINTENANCE 9 HOME CHARGER MODE 2 Series 31328 to 31340 16/32A single phase FCC INFORMATION 9 WARRANTY

More information

PRODUCT/SERVICE CLASSIFICATION CLASS 285 ELECTRICAL EQUIPMENT AND SUPPLIES (EXCEPT CABLE AND WIRE)

PRODUCT/SERVICE CLASSIFICATION CLASS 285 ELECTRICAL EQUIPMENT AND SUPPLIES (EXCEPT CABLE AND WIRE) Please indicate which products and services your company can supply by checking the appropriate box(es). Check only the first box if your company can supply all of the products and services shown for this

More information

INSTALLATION INSTRUCTIONS SURFACE EXTRUSIONS WITH LED TAPE

INSTALLATION INSTRUCTIONS SURFACE EXTRUSIONS WITH LED TAPE LLI-XS-30D LLI-XS-60D LLI-XS-90D LLI-XS-ANG LLI-XS-AUR LLI-XS-DEP LLI-XS-DOM LLI-XS-ELT LLI-XS-FLX LLI-XS-GEN LLI-XS-GZR LLI-XS-ICN LLI-XS-SQR LLI-XS-THN LLI-XS-WID LLI-XS-ZEN **DANGER: Prior to installation,

More information

ACCENT TAPELIGHTS TOKISTAR LIGHTING INCORPORATED

ACCENT TAPELIGHTS TOKISTAR LIGHTING INCORPORATED CCENT TPELIGHTS TOKISTR LIGHTING INCORPORTED T O K I S T R C C E N T T P E L I G H T I N G ccent Tapelighting adapts easily to any design. Flexible cables with low-voltage lamps place special focus on

More information

Transformer Installation, Operation, and Maintenance Manual

Transformer Installation, Operation, and Maintenance Manual Transformer Installation, Operation, and Maintenance Manual CONTENTS INTRODUCTION......................................... 2 INSPECTION UPON RECEIVING... 2 STORAGE...............................................

More information

Flex Strip. Features & Benefits

Flex Strip. Features & Benefits Features & Benefits High quality, high specification High lumen efficiency High brightness Ease of installation Flexible, easily bent Easily cut to length every 1m (220V) or 5cm (12V) Dimmable (5V, 12V

More information

Some models are supplied with a protective film on steel and aluminium parts. This film must be removed before installing/using the appliance.

Some models are supplied with a protective film on steel and aluminium parts. This film must be removed before installing/using the appliance. ELECTRIC RNGE for residential use only R Models: VEFSEE 304 P.. INSTLLTION INSTRUCTIONS IMPORTNT - PLESE RED ND FOLLOW Before beginning, please read these instructions completely and carefully. Do not

More information

MODULE PROFILES 1 1 2" OC. 5. Mounting - Multiple 2 mounting variations including; 1 2" 1 1 2" REQUIRED POWER SUPPLY 3 8" 3 8"

MODULE PROFILES 1 1 2 OC. 5. Mounting - Multiple 2 mounting variations including; 1 2 1 1 2 REQUIRED POWER SUPPLY 3 8 3 8 CAT: TYPE: PROJECT: QTY: PLATINUM COVE TM Low profile PCB modules are attached to continuous through wires to minimize voltage drop and feature stainless steel contacts. FEATURES US Patent # 6,017,241

More information

LED Wall Sconce. Offered with a frosted lens, these wall luminaires provide a high quality diffuse light due to their high CRI of more than 90.

LED Wall Sconce. Offered with a frosted lens, these wall luminaires provide a high quality diffuse light due to their high CRI of more than 90. Luminaires - LED Wall Sconce 04 LED Wall Sconce STANDARD offers two different styles of LED Wall Sconces, one of traditional design and the other more modern with a linear profile. These two models can

More information

Proper installation of this product requires the installer to have a good understanding of automotive electronics, systems and procedures.

Proper installation of this product requires the installer to have a good understanding of automotive electronics, systems and procedures. ENGINEERING COMPANY INC. Route 145, Winthrop Road, Chester, Connecticut 06412 Phone: (860) 526-9504 Fax: (860) 526-4078 Internet: www.whelen.com Sales e-mail: autosale@whelen.com Canadian Sales e-mail:

More information

Harbor Light Model HL General Specifications

Harbor Light Model HL General Specifications Harbor Light Model HL30100 General Specifications Rev.5 02-02-17 Marina Electrical Equipment, Inc. 100 Warwick Court Williamsburg, VA 23185 Toll Free: 1-855-258-3939 Fax: 1-757-258-3988 ALL HARBOR LIGHT

More information

PDX and PX Retrofit Series

PDX and PX Retrofit Series UNIQUE LIGHTING SOLUTIONS PDX and PX Retrofit Series PDX1-1-12-XX PX1-1-12-X-X-XX-65 RETROFIT INSTALLATION GUIDE PDX and PX Series Retrofit WARNING -Retrofit installation must only be performed by a licensed

More information

UltraBright High CRI Series

UltraBright High CRI Series PRODUCT DATA SHEET UltraBright High CRI Series 5 Year Warranty www.flexfireleds.com Description Not all light is created equal. One may assume just because the color temperature, wattage, and LED size

More information

Optimax Pro Retrofit Instructions

Optimax Pro Retrofit Instructions Copyright 2011 by ALL rights reserved. Information in this document is subject to change without notice. Companies, names and data used in examples herein are fictitious unless otherwise noted. No part

More information

CURVABLE NEON-LIKE LIGHTING

CURVABLE NEON-LIKE LIGHTING S P E C I F I C AT I O N S H E E T LUXN EON CURVABLE NEON-LIKE LIGHTING Say goodbye to yesterday s old school neon lighting technologies and say hello to LUXNEON LED Flexible Neon Tube Lighting, designed

More information

AC SERIES ADJUSTABLE CONCEALED LOW VOLTAGE STRIP FOR ADJUSTABLE SHELVES

AC SERIES ADJUSTABLE CONCEALED LOW VOLTAGE STRIP FOR ADJUSTABLE SHELVES TRIM LAMP LAMP OPERATING SERIES PROFILE VOLTAGE AC 0. AC SERIES ADJUSTABLE CONCEALED LOW VOLTAGE FOR ADJUSTABLE SHELVES 7 700K V 7 700K V 00K V 00K V 0 000K V 0 000K V US ETL LISTED, MISCELLANEOUS FITURES,

More information

INDUSTRY WIDE LABOR-MANAGEMENT SAFETY COMMITTEE

INDUSTRY WIDE LABOR-MANAGEMENT SAFETY COMMITTEE INDUSTRY WIDE LABOR-MANAGEMENT SAFETY COMMITTEE SAFETY BULLETIN #23 GUIDELINES FOR WORKING WITH LIGHTING SYSTEMS AND OTHER ELECTRICAL EQUIPMENT All electrical systems and electrically energized equipment

More information

TLT Tapelight Series 12VDC Damp Location High Output Flexible Tapelight

TLT Tapelight Series 12VDC Damp Location High Output Flexible Tapelight 12VDC Damp Location High Output Flexible Tapelight Specifications/Features Tape Light Flexible, low voltage linear LED accent lighting system provides high quality illumination for many indoor applications

More information

OUTPUT CONNECTIONS Bring the wires of the light fixture through the other open knockout and connect them to the power supply output wires.

OUTPUT CONNECTIONS Bring the wires of the light fixture through the other open knockout and connect them to the power supply output wires. MAGNETIC SUPPLY INSTALLATION SAFETY GUIDE Please read before installing. GENERAL This power supply is to be installed in accordance with Article 450 of the National Electric Code. The power supply must

More information

Wireless Dimmer Installation and User Guide

Wireless Dimmer Installation and User Guide Installation Instructions Supported Models and Fixtures Wireless Dimmer Installation and User Guide This installation and user guide covers these dimmer models: LDZ-101-W Wireless Dimmer (802.15.4) LDZ-101-B

More information