Housings and Miscellaneous Parts

Size: px
Start display at page:

Download "Housings and Miscellaneous Parts"

Transcription

1 Housings and Miscellaneous Parts Standard and Special Valve Housings, Orifice Disks, Orifice Sizing harts, Pilot Pistons, dapters, djustment Kits and Seal Kits ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une 003-1

2 Housings and Miscellaneous Parts Section contents Page Standard housings -**-...luminum (Light duty) **-...luminum (NFP fatigue rated) **-...Steel (NFP fatigue rated) **-3/3S...luminum (Light duty) **-3/3S...luminum (NFP fatigue rated) **-3...Steel (NFP fatigue rated) **-3S...Steel (NFP fatigue rated) S...Steel (NFP fatigue rated) special housings for EPV16 only **-4...luminum (Light duty) **-4...luminum (NFP fatigue rated) **-4...Steel (NFP fatigue rated) **-5S...Steel and aluminum (NFP fatigue rated) (special housings for PFRD/S only) Port dimensions - all housings Special Housings - Load control valves Part numbers - V, PO, V housings size V, PO housings size V, PO housings size V housings size V housings Special Housings - olt on manifold for Eaton spool and disk motors Overview Dual V package with brake release shuttle for H & T series Eaton motors Dual PO package with brake release shuttle for H & T series Eaton motors ross over relief valve package for H & T series Eaton motors ross over relief valve package for 000 series Eaton motors Dual V package with brake release shuttle for 000 series Eaton motors Dual PO package with brake release shuttle for 000 series Eaton motors avity plugs Standard cavity plugs Special cavity plugs Orifice discs and orifice sizing chart Orifice discs Orifice sizing chart (Metric) Orifice sizing chart (US units) Miscellaneous parts Pilot pistons Sense check kits and panel mount adapters Miscellaneous parts / adjustment kits djustment kits Seal kits ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une 003

3 -**- luminum housings (Light duty) HOUSING PORTS 1 & PRT NUMER ODE 10 3/8 SPP ()3 SE ()6T 16 3/4 SPP ()6 SE ()1T 0 1 SPP ()8 SE ()16T E D Notes SPP porting is designated by in the model code SE porting is designated by T in the model code. Light duty aluminum housings are intended for applications up to 10 bar (3000 psi) with light to moderate duty cycles. G 1 F I H DIMENSIONS D E F G H I MSS kg (lb) ,8 19,0 50,8 31,7 15,9 19,0 7,1 3,1 1,7 0,1 (.00) (0.75) (.00) (1.5) (0.6) (0.75) (0.8) (0.1) (0.50) (0.35) , 8,5 76, 47,6 3,8 5,4 8,6 4,0 19,0 0,5 (3.0) (1.1) (3.00) (1.87) (0.94) (1.00) (0.34) (0.16) (0.75) (1.1) -0-88,9 34,3 88,9 68,5 34,3 36,8 8,6 4,0 1,6 0,8 (3.5) (1.35) (3.50) (.70) (1.35) (1.45) (0.34) (0.16) (0.85) (1.90) ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une 003-3

4 -**- luminum housings (NFP fatigue rated) HOUSING PORTS 1 & PRT NUMER ODE 8 1/4 SPP ()G 3/8 SPP ()3G SE ()4H SE ()6H SE ()8H 10 1/4 SPP ()G 3/8 SPP ()3G SE ()6H SE ()8H 1 1/ SPP ()4G 3/4 SPP ()6G SE ()10H SE ()1H HOUSING PORTS 1 & PRT NUMER ODE 1 U 1/ SPP ()4G 3/4 SPP ()6G SE ()10H SE ()1H 16 1/ SPP ()4G 3/4 SPP ()6G SE ()10H SE ()1H 0 3/4 SPP ()6G 1 SPP ()8G SE ()1H SE ()16H Notes SPP porting is designated by G in the model code SE porting is designated by either H or T in the model code. E D E D Fatigue rated aluminum housings are intended for applications up to 10 bar (3000 psi) with harsh duty cycles. These housings have been fatigue rated to NFP standards to one million cycles. G G I H 1 I 1 F ll except 1 (U) H 1 (U) F DIMENSIONS D E F G H I MSS kg (lb) -8-50,8 19,0 51,0 38,1 19,0 3,4 15,5 7,1 1,7 0, (.00) (0.75) (.00) (1.50) (0.75) (0.13) (0.61) (0.8) (0.50) (0.46) ,5 5,4 63,5 50,8 5,4 9,5 0,8 7,1 19,0 0,4 (.50) (1.00) (.50) (.00) (1.00) (0.37) (0.81) (0.8) (0.75) (1.00) -1-(U) 88,9 44,5 88,9 50,8 5,4 1,7 8,7 63,5 63,5 0,8 (3.50) (1.75) (3.50) (.00) (1.00) (0.50) (1.13) (.50) (.50) (1.96) ,9 34,9 88,9 63,5 31,7 10,3 8,4 8,7 5,4 1, (3.50) (1.37) (3.50) (.50) (1.5) (0.40) (1.11) (0.34) (1.00) (.75) ,6 38,1 101,6 8,5 41,3 10,3 36,0 8,7 5,4 1,8 (4.00) (1.50) (4.00) (3.5) (1.6) (0.40) (1.41) (0.34) (1.00) (4.00) -4 ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une 003

5 -**- Steel housings (NFP fatigue rated) HOUSING PORTS 1 & PRT NUMER ODE 8 1/4 SPP (S)G 3/8 SPP (S)3G SE (S)4T SE (S)6T SE (S)8T 10 1/4 SPP (S)G 3/8 SPP (S)3G SE (S)6T SE (S)8T 1 1/ SPP (S)4G 3/4 SPP (S)6G SE (S)10T SE (S)1T HOUSING PORTS 1 & PRT NUMER ODE 1 U 1/ SPP (S)4G 3/4 SPP (S)6G SE (S)10T SE (S)1T 16 1/ SPP (S)4G 3/4 SPP (S)6G SE (S)10T SE (S)1T 0 3/4 SPP (S)6G 1 SPP (S)8G SE (S)1T SE (S)16T Notes SPP porting is designated by G in the model code SE porting is designated by T in the model code. E D E D Fatigue rated steel housings are intended for applications up to 350 bar (5000 psi) with harsh duty cycles. These housings have been fatigue rated to NFP standards to one million cycles. F I G F G 1 1 I H H I Ø 1 (U) DIMENSIONS D E F G H I MSS kg (lb) -8-* 50,8 19,0 50,8 38,1 19,0 15,5 38,1 3,3 43,9 7,1 0,5 (.00) (0.75) (.00) (1.50) (0.75) (0.61) (1.50) (0.13) (1.73) (0.8) (1.19) ,5 5,4 63,5 44,4, 19,0 50,8 9,5 44,4 7,1 0,3 (.50) (1.00) (.50) (1.75) (0.87) (0.75) (.00) (0.37) (1.75) (0.8) (0.83) -1-(U) 88,9 8,5 88,9 50,8 5,4 8,7 76, 1,7 63,5 10,3 1,9 (3.50) (1.1) (3.50) (.00) (1.00) (1.13) (3.00) (0.50) (.50) (0.40) (4.8) ,9 38,1 76, 50,8 5,4 5,4 63,5 1,7 63,5 10,3, (3.50) (1.750) (3.00) (.00) (1.00) (1.00) (.50) (0.50) (.50) (0.40) (5.00) ,6 41, 88,9 63,5 31,7 31,7 76, 1,7 76, 10,3 3,6 (4.00) (1.6) (3.50) (.50) (1.5) (1.5) (3.00) (0.50) (3.00) (0.40) (7.96) * 8 series housing utilize a slot instead of a mounting hole. ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une 003-5

6 -**-3/3S luminum housings (Light duty) PORTS PRT HOUSING 1, & 3 NUMER ODE /8 SPP ()3 SE ()6T 10 3S 3/8 SPP ()3 SE ()6T /4 SPP ()6 SE ()1T 16 3S 3/4 SPP ()6 SE ()1T SPP ()8 SE ()1T 0 3S 1 SPP ()8 SE ()16T Notes SPP porting is designated by in the model code SE porting is designated by T in the model code. Light duty aluminum housings are intended for applications up to 10 bar (3000 psi) with light to moderate duty cycles. G I 3 F 1 E H D DIMENSIONS D E F G H I MSS ,5 31,7 66,6 31,7 15,8 3,1 19,0 34,9 7,1 1,7 0,3 (.50) (1.5) (.6) (1.5) (0.6) (0.1) (0.75) (1.37) (0.8) (0.50) (0.64) -10-3S 63,5 34,9 69,8 38,1 19,1 3,1 1,7 31,7 7,1 1,7 0, (.50) (1.37) (.75) (1.50) (0.75) (0.1) (0.50) (1.5) (0.8) (0.50) (0.51) ,6 50,8 107,9 50,8 5,4 4,0 5,4 53,9 8,6 5,4 1,0 (4.00) (.00) (4.5) (.00) (1.00) (0.16) (1.00) (.1) (0.33) (1.00) (.3) -16-3S 88,9 47,6 88,9 60,3 30,1 4,0 17,4 38,1 8,7 19,0 0,7 (3.50) (1.87) (3.50) (.37) (1.63) (0.16) (0.68) (1.50) (0.34) (0.75) (1.66) ,3 57,1 139,7 63,5 31,7 4,0 31,7 7,1 10,4 5,4 1,7 (4.50) (.5) (5.50) (.50) (1.5) (0.16) (1.5) (.84) (0.41) (1.00) (3.9) -0-3S 101,6 57,1 107,9 69,8 34,9 4,0 0,6 50,8 8,7 19,0 1, kg (lb) -6 ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une 003

7 -**-3/3S luminum housings (NFP fatigue rated) PORTS PRT HOUSING 1, & 3 NUMER ODE 8 3 1/4 SPP ()G 3/8 SPP ()3G SE ()4H SE ()6H /4 SPP ()G 3/8 SPP ()3G SE ()6H SE ()8H 10 3S 1/4 SPP ()G 3/8 SPP*** ()3G SE ()6H SE 8** ()8H 1 3 3/8 SPP ()3G 1/ SPP ()4G SE ()10H SE ()1H 1 3S 1/ SPP* ()4G 3/4 SPP* ()6G SE 10** ()10H SE 1** ()1H PORTS PRT HOUSING 1, & 3 NUMER ODE / SPP ()4G 3/4 SPP 8767 ()6G SE ()10H SE ()1H 16 3S 1/ SPP ()4G 3/4 SPP ()6G SE ()10H SE ()1H 0 3 1/ SPP ()4G 3/4 SPP*** ()6G SE ()10H SE ()1H 0 3S 3/4 SPP ()6G 1 SPP ()8G SE ()1H SE ()16H * Port 3 = 3/8 SPP ** Port 3 = SE 6 *** Port 3 = 1/4 SPP Notes SPP porting is designated by G in the model code SE porting is designated by either H or T in the model code. Note Fatigue rated aluminum housings are intended for applications up to 10 bar (3000 psi) with harsh duty cycles. These housings have been fatigue rated to NFP standards to one million cycles. E D G I 3 F 1 H DIMENSIONS D E F G H I MSS kg (lb) ,5 31,8 66,6 38,1 19,0 3,4 15,5 9,8 7,1 13,0 0,4 (.50) (1.5) (.6) (1.50) (0.75) (0.13) (0.61) (1.17) (0.8) (0.51) (0.83) , 38,1 76, 50,8 5,4 9,5 0,8 36,6 7,1 19,0 0,7 (3.00) (1.50) (3.00) (.00) (1.00) (0.37) (0.81) (1.44) (0.8) (0.75) (1.65) -10-3S 76, 38,1 76, 50,8 5,4 9,5 16,8 33,5 7,1 19,0 0,7 (3.00) (1.50) (3.00) (.00) (1.00) (0.37) (0.66) (1.3) (0.8) (0.75) (1.65) ,9 44,5 107,9 50,8 5,4 1,7 8,7 51,6 10,3 1,7 0,8 (3.50) (1.75) (4.5) (.00) (1.00) (0.50) (1.13) (.03) (0.41) (0.50) (1.80) -1-3S 88,9 44,5 101,6 50,8 5,4 1,7 3,0 4,1 10,3 1,7 0,8 (3.50) (1.75) (4.00) (.00) (1.00) (0.50) (0.91) (1.66) (0.41) (0.50) (1.80) ,3 60,3 114,3 63,5 31,7 10,3 8,4 57,0 8,7 5,4,0 (4.50) (.37) (4.50) (.50) (1.5) (0.40) (1.1) (.4) (0.34) (1.00) (4.50) -16-3S 114,3 60,3 114,3 63,5 31,7 10,3 0,4 41,1 8,7 5,4,0 (4.50) (.37) (4.50) (.50) (1.5) (0.40) (0.80) (1.6) (0.34) (1.00) (4.40) ,0 63,5 139,7 8,5 41, 10,3 36,0 76,5 8,7 5,4 3,5 (5.00) (.50) (5.50) (3.5) (1.6) (0.40) (1.4) (3.01) (0.34) (1.00) (7.71) -0-3S 17,0 63,5 17,0 8,5 41, 10,3 4,9 55,0 8,7 5,4 3,6 (5.00) (.50) (5.00) (3.5) (1.6) (0.40) (0.98) (.17) (0.34) (1.00) (8.00) ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une 003-7

8 -**-3 Steel housings (NFP fatigue rated) PORTS PRT HOUSING 1, & 3 NUMER ODE 8 3 1/4 SPP (S)G 3/8 SPP (S)3G SE (S)4T SE (S)6T /4 SPP (S)G 3/8 SPP (S)3G SE (S)6T SE (S)8T 1 3 1/ SPP (S)G 3/8 SPP (S)3G SE (S)10T SE (S)1T / SPP (S)4G 3/4 SPP (S)6G SE (S)10T SE (S)1T 0 3 3/4 SPP (S)6G 1 SPP (S)8G SE (S)1T SE (S)16T K H 1 I 3 E D F G Ø Notes SPP porting is designated by in the model code SE porting is designated by T in the model code. Notes Fatigue rated steel housings are intended for applications up to 350 bar (5000 psi) with harsh duty cycles. These housings have been fatigue rated to NFP standards to one million cycles. DIMENSIONS D E F G H I K MSS kg (lb) -8-3* 63,5 31,8 66,0 38,1 19,0 15,5 53,0 3,3 56,6 7,1 9,8 0,9 (.50) (1.5) (.75) (1.50) (0.75) (0.61) (.1) (0.13) (.3) (0.8) (1.17) (.15) , 38,1 76, 44,4, 19,0 63,5 9,5 57,1 7,1 34,9 1,7 (3.00) (1.50) (3.00) (1.75) (0.87) (0.75) (.50) (0.37) (.5) (0.8) (1.37) (3.75) ,9 44,4 101,6 50,8 5,4 8,7 88,9 1,7 63,5 10,3 51,5 3,0 (3.50) (1.75) (4.00) (.00) (1.00) (1.13) (3.50) (0.50) (.50) (0.40) (.03) (6.75) ,6 50,8 107,9 50,9 5,4 5,4 88,9 1,7 76, 10,3 53,9 3,4 (4.00) (.00) (4.5) (.00) (1.00) (1.00) (3.50) (0.50) (3.00) (0.40) (.1) (7.70) ,3 57,1 139,7 63,5 31,7 31,7 114,3 19,0 76, 11,9 7, 6,4 (4.50) (.5) (5.50) (.50) (1.5) (1.5) (4.50) (0.75) (3.00) (0.47) (.84) (14.30) * 8 Series housings utilize a slot instead of mounting holes. -8 ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une 003

9 -**-3S Steel housings (NFP fatigue rated) PRT HOUSING PORTS 1 & PORT 3 NUMER ODE 10 3S 3/8 SPP 1/4 SPP (S)3G 1/ SPP 1/4 SPP (S)4G SE 6 SE (S)6T SE 8 SE (S)8T SE 10 SE (S)10T 1 3S 1/ SPP 3/8 SPP (S)4G 3/4 SPP 3/8 SPP (S)6G SE 10 SE (S)10T SE 1 SE (S)1T 16 3S 1/ SPP 3/8 SPP (S)6G 3/4 SPP 3/8 SPP (S)6G SE 10 SE (S)10T SE 1 SE (S)1T 0 3S 3/4 SPP 3/8 SPP (S)6G 1 SPP 3/8 SPP (S)8G SE 1 SE (S)1T SE 16 SE (S)16T Notes SPP porting is designated by G in the model code SE porting is designated by T in the model code. E D E D Fatigue rated steel housings are intended for applications up to 350 bar (5000 psi) with harsh duty cycles. These housings have been fatigue rated to NFP standards to one million cycles. K G 3 I F K 3 F G 1 LØ -10 & -1 H H 1 I -16 & -0 LØ DIMENSIONS D E F G H I K LØ MSS kg (lb) -10-3S 63,5 31,8 76, 41,3 0,7 36,6 53,8 11, 53,8 9,7 19,8 8,7 1,08 (.50) (1.5) (3.00) (1.63) (0.8) (1.44) (.1) (0.44) (.1) (0.38) (0.78) (0.34) (.40) -1-3S 88,9 44,5 101,6 50,8 5,4 41,9 76, 31,7 57,1 1,7 3,1 10,3,4 (3.50) (1.75) (4.00) (.00) (1.00) (1.65) (3.00) (1.5) (.5) (0.50) (0.91) (0.40) (5.40) -16-3S 88,9 41, 88,9 50,8 5,4 38,1 69,8 1,7 63,5 19,0 17,4 10,3,6 (3.50) (1.6) (3.50) (.00) (1.00) (1.50) (.75) (0.50) (.50) (0.75) (0.68) (0.40) (5.90) -0-3S 101,6 44,4 114,3 63,5 31,7 50,8 88,9 1,7 76, 5,4 0,6 10,3 4,6 (4.00) (1.75) (4.50) (.50) (1.5) (.00) (3.50) (0.50) (3.00) (1.00) (0.81) (0.40) (10.4) ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une 003-9

10 -16-3S Steel (NFP fatigue rated) Special housings for EPV16 only For use with EPV16- or only HOUSING NUMER LUMINUM STEEL ODE PORT SIZE EPV16- EPV16- EPV16- EPV16-4G 1/ SPP G 3/4 SPP H SE H SE T SE T SE ETOP5 (NFP D05) interface (Requires steel housing) MODEL D E F G ØH MSS kg (lb) lum Steel Modified -16-3S 76, 30, 79, 100,8 38,1 1,7 1,6 8,7 60,4,0 6,0 body (3.00) (1.19) (3.1) (3.97) (1.50) (0.50) (0.85) (0.34) (.38) (4.50) (13.5) Modified housing for use with EPV16-. ØH ( places) Port G F ( places) E Modified housing for use with EPV16-. ØH ( places) Port D "" G F ( places) -10 ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une 003

11 -**-4 luminum housings (Light duty) PORTS 1, PRT HOUSING, 3 & 4 NUMER ODE /8 SPP ()3 SE ()6T /4 SPP ()6 SE ()1T SPP ()8 SE ()16T HOUSING (FD*-**ONLY) /8 SPP ()3 SE ()6T /4 SPP ()6 SE ()1T Notes SPP porting is designated by in the model code SE porting is designated by T in the model code. Note Light duty aluminum housings are intended for applications up to 10 bar (3000 psi) with light to moderate duty cycles. E D E D H H G 3 4 K G 3 4 K I F 1 I F (FD*-**only) DIMENSIONS D E F G H I K MSS ,5 31,7 8,5 31,7 15,8 3,1 34,9 19,0 7,1 9,5 50,8 0,3 (.50) (1.5) (3.5) (1.5) (0.6) (0.1) (1.37) (0.75) (0.8) (0.37) (.00) (0.7) ,6 50,8 133,3 50,8 5,4 3,8 53,9 5,4 8,7, 8,5 1,4 (4.00) (.00) (5.5) (.00) (1.00) (0.15) (.1) (1.00) (0.34) (0.87) (3.5) (3.4) ,3 57,1 117,8 63,5 31,7 4,0 7,1 31,7 10,4 5,4 113,5,6 (4.50) (.5) (7.00) (.50) (1.5) (0.16) (.84) (1.5) (0.41) (1.00) (4.47) (5.76) Note For housings for V valves see page -5. kg (lb) ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une

12 -**-4 luminum housings (NFP fatigue rated) PORTS 1, PRT HOUSING, 3 & 4 NUMER ODE 8 4 1/4 SPP ()G 3/8 SPP ()3G SE ()6H SE ()8H /4 SPP ()G 3/8 SPP ()3G SE ()6H SE ()8H / SPP ()4G 3/4 SPP ()6G SE ()10H SE ()1H 0 4 3/4 SPP ()6G 1 SPP ()8G SE ()1H SE ()16H G I 3 F 1 4 E D H K G I 4 3 F ( FD* **only) E D H K HOUSING (FD*-**ONLY) /4 SPP ()G 3/8 SPP ()3G SE ()6H SE ()8H Notes SPP porting is designated by G in the model code SE porting is designated by either H in the model code. Fatigue rated aluminum housings are intended for applications up to 10 bar (3000 psi) with harsh duty cycles. These housings have been fatigue rated to NFP standards to one million cycles. For and -1-4 housings for V valves see pages -5 & -7 respectively. DIMENSIONS D E F G H I K MSS , 38,1 88,9 50,8 5,4 9,5 36,6 0,8 7,1 1,7 5,5 0,9 (3.00) (1.50) (3.50) (.00) (1.00) (0.37) (1.44) (0.8) (0.8) (0.50) (.07) (.00) ,3 60,3 139,7 63,5 31,7 10,3 57,0 8,4 8,7 5,4 85,5,4 (4.50) (.37) (5.50) (.50) (1.5) (0.40) (.4) (1.1) (0.34) (1.00) (3.37) (5.9) ,0 63,5 177,8 8,5 41, 10,3 76,5 36,0 8,7 19,0 117,8 4,7 (5.00) (.50) (7.00) (3.5) (1.6) (0.40) (3.01) (1.4) (0.34) (0.75) (4.63) (10.5) kg (lb) -1 ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une 003

13 -**-4 Steel housings (NFP fatigue rated) PORTS 1, PRT HOUSING, 3 & 4 NUMER ODE 8 4 1/4 SPP (S)G 3/8 SPP (S)3G SE (S)4T SE (S)6T /4 SPP (S)G 3/8 SPP (S)3G SE (S)6T SE (S)8T / SPP (S)4G 3/4 SPP (S)6G SE (S)10T SE (S)1T 0 4 1/ SPP (S)4G 3/4 SPP (S)6G SE (S)1T SE (S)16T Notes SPP porting is designated by G in the model code SE porting is designated by T in the model code 8 series utilize slot in place of mounting hole. Fatigue rated steel housings are intended for applications up to 350 bar (5000 psi) with harsh duty cycles. These housings have been fatigue rated to NFP standards to one million cycles. For and -1-4 housings for V valves see pages -4 & -7 respectively. L H 3 1 I 4 E D F G Ø K DIMENSIONS D E F G H I K L MSS -8-4* 63,5 31,8 8,6 38,1 19,0 15,5 44,1 3,3 57,1 7,1 73,0 9,8 1, (.50) (1.5) (3.5) (1.50) (0.75) (0.61) (1.74) (0.13) (.5) (0.8) (.88) (1.17) (.70) , 38,1 88,9 44,4, 19,0 50,8 9,5 57,1 7,1 76, 34,9 1,9 (3.00) (1.50) (3.50) (1.75) (0.87) (0.75) (.00) (0.37) (.5) (0.8) (3.00) (1.37) (4.35) ,6 50,8 139,7 50,8 5,4 5,4 8,5 1,7 76, 10,3 10,6 53,9 5,6 (4.00) (.00) (5.50) (.00) (1.00) (1.00) (3.5) (0.50) (3.00) (0.40) (4.75) (.1) (1.40) ,3 57,1 177,8 63,5 31,7 31,7 113,5 19,0 76, 11,8 15,4 7,1 8, (4.50) (.5) (7.00) (.50) (1.5) (1.5) (4.47) (0.75) (3.00) (0.47) (6.00) (.84) (18.0) * 8 Series housings utilize slot instead of mounting holes. kg (lb) ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une

14 -**-5S Steel and aluminum housings (NFP fatigue rated) Special housings for PFRD/S only PORTS LUMINUM PRT STEEL PRT HOUSING,3,4 PORT 5 NUMER ODE NUMER ODE 1 5S SE 10 SE ()10T (S)10T SE 1 SE ()1T (S)1T 1/ SPP 1/4 SPP ()04G (S)04G 3/4 SPP 1/4 SPP ()06G (S)06G 16 5S SE 1 SE ()1T (S)1T SE 16 SE ()16T (S)16T 3/4 SPP 1/4 SPP ()06G (S)06G 1 SPP 1/4 SPP ()08G (S)08G 0 5S SE 1 SE ()1T (S)1T SE 16 SE ()16T (S)16T 3/4 SPP 1/4 SPP ()06G (S)06G 1 SPP 1/4 SPP ()08G (S)08G Notes SPP porting is designated by G in the model code SE porting is designated by T in the model code. Fatigue rated aluminum and steel housings are intended for applications up to 10 bar (3000 psi) and 350 bar (5000 psi) respectively with harsh duty cycles. These housings have been fatigue rated to NFP standards to one million cycles. 4 -**-5S avity 5 Note Port 1 unused, blind cavity is machined into this housing. ETON HYDRULIS, IN. Model Number 3 "499XXXX-XXX" This number will depend on which manifold is ordered DIMENSIONS D E F G H I K L M DIM. N -1-5S 100,8 50,4 96,3 37,3 18,7 16,7 54,0 34,1 73,8 10, 88,9 1,7 88,9 8,7 (3.97) (1.99) (3.79) (1.47) (0.74) (0.66) (.13) (1.34) (.91) (0.40) (3.50) (0.50) (3.50) (0.34) -16-5S 100,8 51,4 113,5 50,0 5,0 16,9 58,8 36,1 81,3 10, 101,6 1,7 88,9 8,7 (3.97) (.0) (4.47) (1.97) (0.99) (.066) (.34) (1.4) (3.0) (0.40) (4.00) (0.50) (3.50) (0.34) -0-5S 113,5 56,8 16, 75,4 37,7 16,8 6,3 37,6 87,4 10, 114,3 1,7 101,6 8,7 (4.47) (.4) (4.97) (.97) (1.49) (0.66) (.45) (1.48) (3.44) (0.40) (4.50) (0.50) (4.00) (0.34) -14 ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une 003

15 Port Key dimensions in all standard housings MINIMUM MINIMUM FULL SE SIZE THRED SIZE SPOTFE Ø THD DEPTH UNF- 1,1 (0.8) 11,5 (0.45) UNF- 4,7 (0.96) 1,7 (0.50) UNF- 30, (1.18) 14, (0.56) UNF- 34, (1.34) 16,6 (0.65) UN- 41,3 (1.6) 19,0 (0.75) UN- 48,6 (1.91) 19,0 (0.75) MINIMUM MINIMUM FULL SPP THRED SIZE SPOTFE Ø THD DEPTH 1/4 4 (0.94) 1, (0.48) 3/8 7 (1.06) 1, (0.48) 1/ 33 (1.9) 15,0 (0.59) 3/4 4 (1.65) 16,3 (0.64) 1 47 (1.85) 19,1 (0.75) Spotface Ø 0,8 (0.03) Min. full thread depth V, PO and V Housings Housing part numbers shown on the following pages are for the counterbalance, vented counterbalance, and pilot-toopen check valves (V1/, V1, PO1). Housing dimensions for inline housings are shown on pages 6, 7 and 9. for other housings are shown on pages -18 to -35. V1/, PO1 VLVE HOUSINGS SIZE 10 HOUSING PORT LUMINUM SIZE 10 SIZE 10 SIZE 1 SIZE 1 TYPE SIZE LIGHT DUTY LUMINUM STEEL LUMINUM STEEL I 3 (3/8 SPP) Inline 6H (SE 6) Mounted 8H (SE 8) T (SE 6) T (SE 8) T (SE 10) T (SE 1) G (1/4 SPP) G (3/8 SPP) G (1/ SPP) G (3/4 SPP) olt Pad 6T (3/4 SE code 61 flange, SE4 pilot port) N 6H (SE 6) lose oupled, 6T (SE 6) Nipple Mounted 8T (SE 8) G (3/8 SPP) G (1/ SPP) G 6H (SE 6) Gasket 6T (SE 6) Mounted, 8T (SE 8) Single 3G (3/8 SPP) G (1/ SPP) ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une

16 V, PO and V Housings (cont.) V1/, PO1 SIZE 10 HOUSING PORT LUMINUM SIZE 10 SIZE 10 SIZE 1 SIZE 1 TYPE SIZE LIGHT DUTY LUMINUM STEEL LUMINUM STEEL D 6H (SE 6) Dual Line 8H (SE 8) Mounted 10H (SE 10) T (SE 6) T (SE 8) T (SE 10) T (SE 10) G (1/4 SPP) G (3/8 SPP) G (1/ SPP) P 6H (SE 6) Dual Gasket 6T (SE 6) Mounted 8T (SE 8) G (3/8 SPP) G (1/ SPP) M 6H (SE 6) Dual 8H (SE 8) ounterbalance 10H (SE 10) Line Mounted 6T (SE 6) w/integral 8T (SE 8) Shuttle Valve 10T (SE 10) T (SE 10) G (1/4 SPP) G (3/8 SPP) G (1/ SPP) H 10T (SE 10) K 10T (SE 10) Dual ounterbalance olt on Manifolds for Eaton Hydraulic Motors V VLVE HOUSINGS SIZE 10 HOUSING PORT LUMINUM SIZE 10 SIZE 10 SIZE 1 SIZE 1 TYPE SIZE LIGHT DUTY LUMINUM STEEL LUMINUM STEEL I 6H (SE 6) Inline 8H (SE 8) * Mounted 10H (SE 10) * T (SE 6) T (SE 8) * T (SE 10) * T (SE 1) - * * ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une 003

17 V, PO and V Housings (cont.) V valve housings SIZE 10 HOUSING PORT LUMINUM SIZE 10 SIZE 10 SIZE 1 SIZE 1 TYPE SIZE LIGHT DUTY LUMINUM STEEL LUMINUM STEEL I G (1/4 SPP) G (3/8 SPP) * * G (1/ SPP) * * G 6H (SE 6) Gasket 8H (SE 8) Mounted, 6T (SE 6) Single 8T (SE 8) G (3/8 SPP) G (1/ SPP) D 6H (SE 6) Dual Line 8H (SE 8) Mounted 6T (SE 6) T (SE 8) T (SE 10) T (SE 1) * * G (3/8 SPP) G (1/ SPP) - * * * Housings with slot PPROXIMTE WEIGHT KG. (LS) FOR V, PO & V VLVE HOUSINGS LUMINUM STNDRD LUMINUM STNDRD LUMINUM STEEL STEEL V/PO V LIGHT DUTY V/PO V SIZE SIZE SIZE SIZE SIZE SIZE SIZE SIZE SIZE SIZE SIZE HOUSING I 0,75 0,8 1,18 0,85 0,95 0,3 1,08,63 3,40 1,3 3,05 (1.65) (1.80) (.60) (1.87) (.09) (0.51) (.40) (5.40) (7.50) (.71) (6.7) 0,86,61 (1.90) (5.75) N 0,49 0,91 1,49,7 (1.10) (.00) (3.30) (6.00) G 0,67 0,73 0,85 0,95,49,15 1,3 3,05 (1.85) (1.60) (1.87) (.09) (5.50) (4.75) (.71) (6.7) D 0,79 1,11 1,77 1,60 1,10,38 3,33 5,14,55 3,70 (1.75) (.45) (3.90) (3.5) (.4) (5.5) (7.35) (11.30) (5.6) (8.15) P 0,7,0,17 5,90 (1.60) (4.40) (4.80) (10.00) H 1,4 (.73) K 1,67 (3.67) ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une

18 Size 10 Housings V1/ and PO1 I Inline, aluminum & steel PORT SIZE 1 3 6T SE 6 SE 6 SE 6 3 3/8 SPP 3/8 SPP 3/8 SPP See standard inline housings: Light duty housings - page -6 Fatigue rated housings - page -7 Steel housings - page -9 N - lose coupled nipple mounted - aluminum and steel (NFP fatigue rated) PORT SIZE LUMINUM STEEL 1,V1,V 6H 6T SE 8 SE 6 3G 3G 3/8 SPP 3/8 SPP See page -15 for housing part numbers. 14, (0.56) 40,6 (1.60) 18,3 (0.7) 18,3 (0.7) 14, (0.56) V 65,5 (.58) 81,8 (3.) V1 37,8 (1.49) 1 59,4 (.34) 45,4 (1.79) avity 75,4 (.97) -18 ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une 003

19 Size 10 Housings V1/ and PO1 G - Gasket mounted, single - aluminum and steel (NFP fatigue rated) PORT SIZE LUMINUM STEEL 1,V1,V 6H 6T Ø 1,7(0.5) SE 6 3G 3G Ø 1,7(0.5) 3/8 SPP See page -15 for housing part numbers. avity 41,3 (1.63) 56,4 (.) 19,8 (0.78) 7,8 (0.31) Dia. thru 1,7 (0.5) Dia c bore x 6,35 (0.5) places 1 V1 19,1 (0.75) 38,1 (1.50) 6,7 (.47) 94,5 (3.7) 57,9 (.8) V 17,5 (0.69) 15,9 (0.63) 57,9 (.8) 44,5 (1.75) 6,7 (.47) 15,7 (0.6) 38,1 (1.50) 1 Port -113 O-ring D - Dual line mounted - aluminum and steel (NFP fatigue rated) PORT SIZE LUMINUM STEEL 1,,V1,V 6H 6T SE 6 8H 8T SE 8 10H 10T SE 10 G G 1/4 SPP 3G 3G 3/8 SPP 4G 4G 1/ SPP See page -15 for housing part numbers. 36,5 (1.44), (0.88) 77,1 (3.03) artridge cavity 44,5 (1.75) V1 75,4 (.97) 31,8 (1.5) Ø 8,6 (0.34) 63,5 through (.50) places 31,8 (1.5) V 44,5 (1.75),3 (0.88) 16,7 (0.66) 36,5 (1.44), (0.88) 80,6 (3.16) 113,5 (4.47) 77,1 (3.03), (0.88) 44,5 (1.75) 1 ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une

20 Size 10 Housings V1/ and PO1 P - Dual gasket mounted - aluminum and steel (NFP fatigue rated) PORT SIZE LUMINUM STEEL 1,V1,V 6H 6T Ø 1,7(0.5) SE 6 3G 3G Ø 1,7(0.5) 3/8 SPP See page -15 for housing part numbers. 49,5 (1.95) 55,9 (.0) avity 46,1 (1.8) 1 O-Ring ,3 (4.50) 58,4 (.30) avity V 75,4 (.97) 49,5 (1.95) 36,6 (1.44) 31, (1.3) 14, (0.56) 6,7 (.47) 8,6 (0.34) diameter c'bore x 6,35 (0.5) deep plcs (1.95) 16,3 (0.64) 46,7 (1.84) V1,1 (0.87) M - Dual line mounted - aluminum and steel (NFP fatigue rated) PORT SIZE 1,, LUMINUM STEEL V1,V S 6H 6T SE 6 SE 4 8H 8T SE 8 SE 4 10H 10T SE 10 SE 4 G G 1/4 SPP 1/4 SPP 3G 3G 3/8 SPP 1/4 SPP 4G 4G 1/ SPP 1/4 SPP See page -15 for housing part numbers. V1 31,8 (1.5) 75,4 (.97) avity 8,6 (0.34) Dia. thru plcs. S 31,8 44,5 (1.5) (1.75) 63,5 (.5) V 44,5 (1.75) 16,8,3 (0.66) (0.88) 93,5 (3.68) 63,5 (.5) 17,0 (5.00),3 (0.88),3 (0.88) 44,5 (1.75) 90,4 (3.56) 36,6 (1.44) 1-0 ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une 003

21 Size 1 Housings V1/ and PO1 I - Inline body - aluminum and steel (NFP fatigue rated) PORT YLINDER- VLVE- PILOT- SIZE PORT (1) PORT () PORT (3) 10T SE 10 SE 6 1T SE 1 SE 6 4G 1/ SPP 3/8 SPP 6G 3/4 SPP 3/8 SPP See page -15 for housing part numbers. See standard inline housings: luminum housings - page -7 Steel housings - page -9-3/4 4-olt Pad - aluminum and steel (NFP fatigue rated) PORT SIZE 1 PILOT- PORT 6T 3/4 SE 4 bolt SE 6 ode 61 See page -15 for housing part numbers. V 1,7 (0.5) x deep, places 6,7 (.47) 47,6 (1.88) 31,8 (1.5) 7,9 (0.3) 100,8 (3.97) 5,4 (.06) 63,5 (.5) avity Pilot Pilot 7,9 (0.31) 8,6 (1.13) 77,8 (3.06) 19,1 30, (1.19) (0.75), (0.88) 8,6 (1.13) 11, 8 (1.5) 6,7 (.47) 8,6 (1.13) 77,8 (3.06) 31,8 (1.5) 1 ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une 003-1

22 Size 1 Housings V1/ and PO1 N - lose coupled nipple mounted - aluminum and steel (NFP fatigue rated) PORT SIZE 1, V1, V 8T 1/ NPTF SE 8 4G 1/ SPP 1/ SPP See page -15 for housing part numbers. artridge cavity V 7, (.84) 39,7 (1.56) 7, (.84) V1 88,1 (3.47) 1 39,7 (1.56) 0,6 (.81) 33,3 (1.31) 50,0 (1.97) 15,9 (0.63) 0,6 (0.81) 33,3 (1.31) 69,9 (.75) 100,8 (3.97) G - Gasket mounted, single - aluminum and steel (NFP fatigue rated) PORT SIZE 1, V1, V 8T Ø 15,8(0.65) SE 8 4G Ø 15,8(0.65) 1/ SPP See page -15 for housing part numbers. 10,3 (0.41) Dia. thru 15,0 (0.59) dia. c'bore x 7,8 (0.31) deep, places artridge cavity 70,6 (.78) V1 6,7 (.47) V 45, (1.78) 1 Port O-Ring ,3 (1.79) 17,5 (0.69) 17,4 (0.69) 45,4 (1.79) 3,0 (0.91) 67,5 (.66) 75,4 (.97) 19,1 (0.75) 44,5 (1.75) 6,7 (.47) 3,1 (0.91) 70,6 (.78) 113,5 (4.47) - ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une 003

23 Size 1 Housings V1/ and PO1 D - Dual line mounted - aluminum and steel (NFP fatigue rated) PORT SIZE 1,, V1, V 10T SE 10 1T SE 1 4G 1/ SPP See page -15 for housing part numbers. artridge cavity V1 4,0 (1.66) 76, 88,1 (3.00) (3.47) 10,3 (0.41) dia. thru places 4,0 (1.66) V 50,8 (.00) 5,4 (1.00) 40,9 (1.61) 88,9 (3.50) 16, (4.97) 96,1 (3.91) 5,4 (1.00) 5,4 (1.00) 1 P - Dual gasket mounted (NFP fatigue rated) PORT SIZE 1, V1, V 8T Ø 15,8(0.65) SE 8 4G Ø 15,8(0.65) 1/ SPP See page -15 for housing part numbers. artridge cavity 6,9 (1.06) 68,3 (.7) 88,0 (3.47) 88,1 (3.47) 58,3 (.30) 44,7 (1.76) 35,8 (1.40) 9,8 (1.18) 133,4 (5.5) 67,9 (.67) 10.3 (0.41) dia. thru, 15.0 (0.59) dia. c"bore x 7.9 (0.31) deep, places 7,1 (1.06) artridge cavity V V1 7,1 (1.06) 50,1 (1.97) 68,9 (.7) 88,1 (3.47) 67,8 (.67) 1 - O-Ring 117 ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une 003-3

24 Size 1 Housings V1/ and PO1 M - dual line mounted - with integral shuttle, counter balance only (NFP fatigue rated) 1, PORT SIZE V1, V S 10T SE 10 SE 4 1T SE 1 SE 4 4G 1/ SPP 1/4 SPP See page -15 for housing part numbers. artridge cavity V1 4,0 (1.66) 88,1 (3.47) 10,3 (0.41) dia. through, places S 56,4 (.5) 76, (3.00) 4,0 (1.66) V 50,8 (.00) 5,4 (1.00) 39,7 (1.56) 5,4 (1.00) 1,7 (0.50) 101,6 (4.00) 69,5 (.74) 16, (4.97) 86,5 (3.41) 1 5,4 (1.00) -4 ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une 003

25 Size 10 Housings V1-10 I - Inline body - aluminum, light duty PORT SIZE 1,, 3 & 4 6T SE 6 See page -15 for housing part numbers. 15,8 (0.6) 31,7 (1.5) artridge cavity 63,5 (.50) 31,7 (1.5) 19,0 (0.75) 3 34,9 (1.37) 50,8 (.00) 8,5 (3.5) 4 3,1 (0.1) 7,1 (0.8) places 1 I - Inline body - aluminum (NFP Fatigue Rated) PORT SIZE 1 & 3 & 4 8H SE 8 SE 6 10H SE 10 SE 6 3G 3/8 SPP 1/4 SPP See page -15 for housing part numbers. 5,4 (1.00) 50,8 (.00) 5,4 (1.00) 3 9,5 (0.37) artridge cavity 88,9 (3.50) 76, (3.00) 38,1 (1.50) 76, (3.00) 19,0 (0.75) 5,4 (1.00) 4 50,8 (.00) 57, (.5) 7,1 (0.8) places 1 ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une 003-5

26 Size 10 Housings V1 I - Inline body - Steel (NFP fatigue rated) PORT SIZE 1 & 3 &4 6T SE 8 SE 6 8T SE 10 SE 6 3G 3/8 SPP 1/4 SPP See page -15 for housing part numbers., (0.87) 3 9,5 (0.37), (0.87) artridge cavity 88,9 (3.50) 76, (3.00) 44,4 (1.75) 38,1 (1.50) 76, (3.00) 19,0 (0.75) 5,4 (1.00) 4 50,8 (.00) 57, (.5) 7,1 (0.8) places G - Gasket mounted, single aluminum and steel (NFP fatigue rated) PORT SIZE LUMINUM STEEL VENT 1, V1, V 6H 6T SE 6 Ø 1,7 SE 6 (0.500) N/ 8T SE 6 Ø 1,7 SE 8 (0.500) 3G 3G 1/4 SPP Ø 1,7 3/8 SPP (0.500) See page -15 for housing part numbers. 1 V1 artridge cavity 36,5 (1.44) 15,7 (0.6) 46,7 (1.84) 75,4 (.97) 65,0 (.56) 8,4 (1.1) 9, (1.15) 75,4 (.97) 36,5 (1.44) 15,7 (0.6) 1 Port -113 O-ring 46,7 (1.84),3 (0.88) 7,8 (0.31) Dia. thru 1,7 (0.5) c'bore x 6,35 (0.5) deep places 50,8 (.00) 100,8 (3.97) 81,7 (3.) Vent -6 ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une 003

27 Size 10 Housings V1 D - Dual line mounted - aluminum and steel (NFP fatigue rated) PORT SIZE 1,, LUMINUM STEEL V1 & V VENT 6H 6T SE 6 SE 4 8H 8T SE 8 SE 4 3G 3G 3/8 SPP 1/4 SPP See page -15 for housing part numbers. 31,7 (1.5) 31,7 (1.5) artridge cavity places 68,0 (.68) 50,8 V 88,1 (.00) (3.47) 75,4 Ø 8,6 (0.34) (.97) places 50,8 (.00) 19,0 Vent (0.75) V1 34,0 (1.34) 16,7 (0.66) 31,7 (1.5) 31,7 (1.5) 8,5 (3.5) 100,8 (3.97) 68,0 (.68) 3,1 (0.91) 31,7 (1.5) 50,0 (1.97) 50,0 (1.97) 1 Size 1 Housings V1 artridge cavity 88,9 (3.50) 5,4 (1.00) 44,5 ( 1.75) 50,8 (.00) 5,4 (1.00) Tank port I - Inline body - luminum and Steel PORT SIZE 1 & 3 & 4 10T SE 10 SE 6 1T SE 1 SE 6 4G 1/ SPP 1/4 SPP See page -15 for housing part numbers. 3 51,6 (.03) Pilot port 10,6 (4.75) 10,7 (0.4) dia. through, places ylinder port 1 57,1 (.5) 1,7 (0.50) 44,5 (1.75) 8,7 (1.13) Valve port 4 74,5 (.93) ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une 003-7

28 Size 1 Housings V1 G - Gasket mounted, single aluminum and steel (NFP fatigue rated) PORT SIZE VENT 1, V1, V 8T SE 6 Ø 15,8(0.65) SE 8 4G 1/4 SPP Ø 15,8(0.65) 1/ SPP See page -15 for housing part numbers. V V1 36,5 (1.44) 16,7 (0.66) 5,5 (0.7) 88,1 (3.47) 36,8 (1.75) 3,7 (1.9) 31,7 (1.5) 75,4 (.97) 36,5 (1.44) 16,7 (0.66) 1 Port -117 O-ring 54,8 (.16) 19,0 (0.75) 10,4 (0.41) Dia. thru 14,9 (0.59) c'bore x 7,87 (0.31) deep places 50,8 (.00) 13,5 (5.) 103,8 (4.09) Vent artridge cavity D - Dual line mounted - aluminum and steel (NFP fatigue rated) 1,, PORT SIZE V1 & V VENT 10T SE 10 SE 6 1T SE 1 SE 6 4G 1/ SPP 1/4 SPP See page -15 for housing part numbers. 41, (1.6) 5,4 (1.00) artridge places 85,3 (3.36) 74,7 V 10,6 (.93) (4.75) 107,9 Ø10,6 (0.4) (4.5) places 74,4 (.93) 45,7 Vent (1.80) V1 37,9 (1.49) 19,0 (0.75) 41, (1.6) 37,3 (1.47) 88,9 (3.50) 16, (4.97) 85,3 (3.36) 8,5 (1.1) 37,3 (1.47) 6,7 (.47) 6,7 (.47) 1-8 ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une 003

29 Special Housings olt on Solutions artridge Valves & Manifolds for Spool & Disk Valve Motors We Manufacture Solutions Designing hydraulic systems with Eaton-Vickers artridge Valves & Manifolds is a cost effective way of bringing your design into production well within the most demanding of production schedules. Minimizing the use of hoses, tubing and fittings will reduce production and assembly time significantly. Features ompatible with Eaton H & T series spool valve motors, and most 000 series disk valve motors luminum Manifolds nodized lack Pre-set cartridges to your specifications 100% production tested assembly Wide range of settings available Intelligent model code Manifolds are available with out cartridge valves, or pre-assembled and tested to your specifications Manifolds and motors can be supplied as a pre-assembled package Dual counterbalance valve (with integral shuttle valve), dual pilot operated check valve and dual cross port relief valve packages are available Eaton H Series Hydraulic Motor ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une 003-9

30 Dual V Package for H&T Series Motors artridge valves & manifolds for spool valve motors Dual ounterbalance Valve ssembly with rake Release Shuttle When the motor is in a stationary, unpowered mode, this assembly will prevent excessive drift in either direction of rotation. It will also prevent motor overspeed when exposed to an overrunning load, and will control motor deceleration to a stop. shuttle within the assembly provides a pilot to release a parking or holding brake as either motor port is pressurized. Typical applications are swing drives, winch drives, and vehicle propulsion circuits. If the shuttle is not required the rake port may be plugged. Functional Symbol How to Order omplete pre-assembled packages are specified using the V*-10 model code, position 6 of RTINGS ND SPEIFITIONS the model code is H. To order the manifold subassembly, without the two V valves, but with rake SE4 6,74 [.470] integral shuttle valve order Rated flow 60L/min(15USgpm) Rated pressure 10 bar (3000 psi) Internal leakage (maximum) 5 drops/min 77% of crack pressure Pilot ratio 4:1 or 10:1 Manifold sub-assembly only Installation kit (includes cap screws, washers and o-rings) For detailed specifications refer to the V*-10 data sheet on page H-6 Port Sizes, SE10 rake 88,14 [3.470] 53,4 [.103] 63,5 [.500] "" "" 31,74 [1.50] 57,15 [.50] "" "" ETON HYDRULIS, IN. Model Number "rake" 100,84 [3.970] 1,7 [0.500] 4XØ 8,71 [0.343] 19,53 [0.769] 44,45 [1.750] 69,37 [.731] -30 ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une 003

31 Dual PO Package for H&T Series Motors artridge valves and manifolds for spool valve motors Dual Pilot Operated heck Valve ssembly When the motor is in a stationary, unpowered mode, this assembly will prevent excessive drift in either direction of rotation. lthough it not designed to modulate the flow of oil to or from the motor, it will also prevent motor runaway if an overrunning load exists in the powered mode. shuttle within the assembly provides a pilot to release a parking or holding brake as either motor port is pressurized. If the shuttle is not required the rake port may be plugged. How to Order omplete pre-assembled packages are specified using the PO1-10 model code, position 6 of the RTINGS ND SPEIFITIONS Rated flow 60L/min(15USgpm) Rated pressure 10 bar(3000psi) Internal leakage (maximum) less than psi Pilot ratio 3:1 Manifold sub-assembly Installation kit (includes cap screws, washers and o-rings) For detailed specifications refer to the PO1-10 data sheet on page G-36 model code is H. To order the manifold sub-assembly, without the two PO1 valves, but with integral shuttle valve order Functional Symbol 6,74 [.470] Port Sizes, SE10 rake SE4 88,14 [3.470] 7,16 [0.8] rake "" 63,5 [.500] "" ETON HYDRULIS, IN. Model Number "" "rake" "" 31,74 [1.50] 57,15 [.50] 100,84 [3.970] 1,7 [0.500] 4XØ 8,71 [0.343] 44,45 [1.750] 69,37 [.731] 19,53 [0.769] ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une

32 Dual ross-over Relief Package for H&T Series Motors artridge valves & manifolds for spool valve motors Dual rossover Relief Valve ssembly This valve assembly provides motor overpressure protection in both directions of rotation, while supplying the return or lower pressure side of the motor with makeup oil. If closed center valving is used, an additional function is controlled braking. Typical applications are vehicle propulsion and motor work circuits in which pressure limiting is required. How to Order omplete pre-assembled packages are specified using the RV3-10 model code. Option must be RTINGS ND SPEIFITIONS Rated flow 76 L/min(0USgpm) Rated pressure 10 bar (3000psi) Internal leakage (maximum) less than 5 85% of nominal setting Manifold sub-assembly only Installation kit (includes cap screws, washers and o-rings) For detailed specifications refer to the RV3-10 data sheet on page E-1 selected for the cage seals, position 6 of the model code is H. To order the manifold separately, without the two RV3 cartridges, order the part number Functional Symbol Port Sizes, SE10 rake SE4 5,5 [.057] 4XØ 8,71 [0.343] 50,8 [.000] ETON HYDRULIS, IN. "" 4,13 [0.950] 88,14 [3.470] 65,0 [.560] "" 69,85 [.750] "" Model Number "" 4,13 [0.950] 44,45 [1.750] 6,74 [.470] 1,98 [0.078] 75,44 [.970] 1,98 [0.078] -3 ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une 003

33 Dual ross-over Relief Package for 000 Series Disc Valve Motors artridge valves & manifolds for disc valve motors Dual rossover Relief Valve ssembly This valve assembly provides motor overpressure protection in both directions of rotation, while supplying the return or lower pressure side of the motor with makeup oil. If closed center valving is used, an additional function is controlled braking. Typical applications are vehicle propulsion and motor work circuits in which pressure limiting is required. Functional Symbol How to Order omplete pre-assembled packages are specified using the RV3-10 model code. Option must be selected for the cage seals, RTINGS ND SPEIFITIONS position 6 of the model code is K. To order the manifold separately, without the two RV3 cartridges, order Rated flow 76 L/min(0USgpm) Rated pressure 10 bar (3000psi) Internal leakage (maximum) less than 5 85% of nominal setting Manifold sub-assembly only Installation kit (includes cap screws, washers and o-rings) For detailed specifications refer to the RV3-10 data sheet on page E-14 Port Sizes, SE10 rake SE4 WRNING This manifold package may not be suitable for application with all 000 series motors - please check installation dimensions carefully. 5,5 [.057] 3XØ10,31 [0.406] "" 44,45 [1.750] ETON HYDRULIS, IN. Model Number "" "" 56,03 [.06] 8,55 [3.50] 100,84 [3.970] 6,35 "" [0.50] 53,85 [.10] 8,45 [1.10] 6,74 [.470] 1,98 [0.078] 88,14 [3.470] 1,98 [0.078] ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une

34 Dual V Package for 000 Series Disc Valve Motors artridge valves & manifolds for disc valve motors Dual ounterbalance Valve ssembly When the motor is in a stationary, unpowered mode, this assembly will prevent excessive drift in either direction of rotation. It will also prevent motor overspeed when exposed to an overrunning load, and will control motor deceleration to a stop. shuttle within the assembly provides a pilot to release a parking or holding brake as either motor port is pressurized. Typical applications are swing drives, winch drives, and vehicle propulsion circuits. If the shuttle is not required the rake port may be plugged. Functional Symbol How to Order omplete pre-assembled packages are specified using the V*-10 model code, position 6 of the RTINGS ND SPEIFITIONS Rated flow 60L/min(15USgpm) Rated pressure 10 bar (3000 psi) Internal leakage (maximum) 5 drops/min 77% of crack pressure Pilot ratio 4:1 or 10:1 Manifold sub-assembly only Installation kit (includes cap screws, washers and o-rings) For detailed specifications refer to the V*-10 data sheet on page H-6 6,74 [.470] model code is K. To order the manifold subassembly, without the two V valves, but with Port Sizes, SE10 rake SE4 integral shuttle valve order WRNING This manifold package may not be suitable for application with all 000 series motors - please check installation dimensions carefully. rake 100,84 [3.970] 53,4 [.103] 57,15 [.50] ETON HYDRULIS, IN. Model Number "" "" 31,74 [1.50] 76,81 [3.04] 113,54 [4.470] "" "rake" 17,78 [0.700] "" 3XØ 10,31 [0.406] 50,8 [.000] 76,87 [3.07] 3,46 [0.94] -34 ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une 003

35 Dual PO Package for 000 Series Disc Valve Motors artridge valves & manifolds for disc valve motors Dual Pilot Operated heck Valve ssembly When the motor is in a stationary, unpowered mode, this assembly will prevent excessive drift in either direction of rotation. lthough it not designed to modulate the flow of oil to or from the motor, it will also prevent motor runaway if an overrunning load exists in the powered mode. shuttle within the assembly provides a pilot to release a parking or holding brake as either motor port is pressurized. If the shuttle is not required the rake port may be plugged. How to Order omplete pre-assembled packages are specified using the PO1-10 model code, position 6 of the model code is K. To order the manifold subassembly, without the two PO1 valves, but with integral shuttle valve order RTINGS ND SPEIFITIONS Rated flow 60L/min(15USgpm) Rated pressure 10 bar(3000psi) Internal leakage (maximum) less than psi Pilot ratio 3:1 Manifold sub-assembly only Installation kit (includes cap screws, washers and o-rings) For detailed specifications refer to the PO1-10 data sheet on page G-36 Port Sizes, SE10 rake SE4 Functional Symbol 6,74 [.470] 100,84 [3.970] 7,16 [0.8] rake 57,15 [.50] ETON HYDRULIS, IN. Model Number "" "" 31,74 [1.50] 76,81 [3.04] 113,54 [4.470] "" "rake" 17,78 [0.700] "" 3XØ 10,31 [0.406] 50,8 [.000] 76,87 [3.07] 3,46 [0.94] ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une

36 avity Plugs STNDRD PLUGS Note To block flow from between the ports in any unused standard cavity, in a housing or manifold. Order cavity plugs by part number. -**- avity Plugs SIZE SSY. NO. SEL KIT To fit una-n cavity ød Viton ,1 7,8 1,6/1, (0.36) (1.09) (0.498/0.496) ,9 31,7 15,8/15, (0.30) (1.5) (0.6/0.6) ,7 44,5 3,7/3, (0.74) (1.75) (.936/.934) ,7 44,5 8,5/8, (0.50) (1.75) (1.1/1.1) ,5 57, 36,4/36, (0.53) (.5) (1.43/1.43) Thread 1 D -**-3(S) avity Plugs Thread 3 1 D E SIZE SSY. NO. SEL KIT To fit una-n cavity D E Viton ,1 40,7 14,/14,0 15, (0.36) (1.60) (0.56/0.55) (0.63/0.61) S ,9 74, 17,4/17,4 19,0/18, (0.30) (1.86) (0.68/0.68) (0.74/0.74) ,0 15,8/15,7 17,4/17, (1.81) (0.6/0.6) (0.68/0.68) S ,7 57,7,1/, 1 3,7/3, (0.74) (.7) (0.874/0.87) (0.936/0.934) , (.64) S ,7 55,6 5,3/5,3 8,5/8, (0.50) (.18) (0.99/0.99) (1./1.) ,1 6,9/6,9 8,5/8, (,87) (1.06/1.06) (1./1.) S , ,3/33, 36,4/36, (0.53) (3.0) (1.31/1.30) (1.43/1.43) ,3/33, 36,4/36, (3.87) (1.31/1.30) (1.43/1.43) ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une 003

37 avity Plugs -**-4 avity Plugs 4 3 Thread TO FIT SSY VITY SIZE D ØE ØF ØG NO , (0.87) hex. 8,6 54,6 1,6 14, 15, Torque (0.34) (,15) (0.49) (0.55) (0.6) Nm(5-30 lbf ft) -10-4(U) ,4 (1.0) hex. 7,9 61,9 15,8/15,7 17,4/17,3 19,0/18, Torque (0.31) (.43) (0.6/0.6) (0.68/0.68) (0.74/0.74) Nm (35-40 lbf ft) ,1 (1.50) hex. 1, ,3/5,3 6,9/6,9 8,5/8, Torque (0.50) (4.00) (0.99/0.99) (1.06/1.05) (1.1/1.1) Nm (80-90 lbf ft) ,6 (1.87) hex. 13,5 139,7 31,7/31,6 33,3/33, 36,4/36, Torque (0.53) (5.50) (1.4/1.4) (1.31/1.30) (1.43/1.43) Nm ( lbf ft) 1 D E F IMPORTNT The cartridges listed are complete with seals compatible with antiwear hydraulic oil. If cartridges are to be compatible with antiwear and phosphate ester, order cartridges by part number plus the appropriate Viton seal kit as listed in Spare parts. efore using the cartridge, change the seals to Viton. Special purpose cavity plugs Functional Symbols Filter cartridge plugs TO FIT VITY SIZE SSY. NO. SEL KIT (una-n) (Viton ) Screen fitted on cartridge, intended direction of flow is from port to 1 only. Maximum rated flow is 76 L/min (0 USgpm), maximum operating pressure is 350 bar (5000 psi) 1 Special 3 way cavity plugs Special 4 way cavity plugs 1 TO FIT VITY SIZE SSY. NO. SEL KIT (una-n) (Viton ) -10-3S (una-n) (Viton ) TO FIT VITY SIZE SSY. NO. SEL KIT (una-n) (Viton ) TO FIT VITY SIZE SSY. NO. SEL KIT (una-n) (Viton ) 3 4 ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une

38 Orifice Discs lank Orifice Discs (Flat) lank Orifice Discs (Flat) lank Orifice Discs (Flat) lank Orifice Discs (Flat) Note For predrilled orifice discs, consult factory. n orifice disc is installed at the bottom of a standard cavity to create a local pressure drop in the flow to and from port 1 of the cartridge. Two series of discs are available according to the maximum pressure drop required: 1. Flat discs/maximum pressure drop/13,8 bar (00 psi).. onical discs/maximum pressure drop/10 bar (3000 psi). MX PRESSURE VITY DROP R SSY SIZES (PSI) Ø Ø NUMER -8-/4 13,8 (00) 1,45 (0.490) 1,7 (0.050) * /3/4 13,8 (00) 5,80 (0.6) 15,75 (0.60) 1,5 (0.060) * ,8 (00) 8,58 (1.15) 8,5 (1.13),03 (0.08) * ,8 (00) 6,97 (1.06) 6,9 (1.060),03 (0.08) * -16-3S/4 13,8 (00) 5,4 (1.00) 5,35 (0.998),03 (0.08) * *User to specify ± 0,05 (0.001) Ø lank Orifice Discs (onical) MX PRESSURE VITY DROP R SSY SIZES (PSI) Ø Ø Ø D E F NUMER -8-/4 10 (3000) 3,96 (0.156) 5,84 (0.30) 1,45 (0.490) 1,90 (0.075) 3,05 (0.10) (3000) 3,96 (0.156) 5,84 (0.30) 14,05 (0.553) 1,90 (0.075) 3,05 (0.10) (3000) 5,54 (0.18) 6,35 (0.50) 15,80 (0.6) 1,14 (0.045) 3,56 (0.140) ,75 (0.60) (3000) 7,14 (0.81) 3,70 (0.933),41 (0.095) 3,56 (0.140) 1,14 (0.045) ,65 (0.931) Orifice diameter ± 0,05 (0.001) To abut port 1 of cartridge D F D E -38 ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une 003

39 Orifice Disc Sizing Guide (mm) Select required orifice diameter using the graph below Flow - L/min dp - (psi) Note This chart is calculated at 1.8 cst and 49 for ISO VG3 fluid (DTE-4), values will change with viscosity changes dp - (bar) Note To calculate orifice diameter at other flows and differential pressures use the following formula: D=1.350 x (Q/( dp) Note where D= orifice diameter in millimeters; Q= flow in liters per minute; dp= differential pressure across orifice in R Flow - USgpm ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une

Housings and miscellaneous parts

Housings and miscellaneous parts Hydraulic Screw-in artridge Valves (SiV) Housings and miscellaneous parts Standard and special valve housings, orifice disks, orifice sizing charts, pilot pistons, adapters, adjustment kits and seal kits

More information

Proportional Valves. Proportional solenoid valves for pressure and flow control

Proportional Valves. Proportional solenoid valves for pressure and flow control Proportional Valves Proportional solenoid valves for pressure and flow control EATON Vickers Screw-In Cartridge Valves V-VLOV-MC-E4 September, 7 - Electro- Proportional Valves Section Contents Typical

More information

SV9A-10-E - Solenoid Valve 4-way, 3-position spool type solenoid valve Up to 36 L/min (9.5 USgpm) 210 bar (3000 psi)

SV9A-10-E - Solenoid Valve 4-way, 3-position spool type solenoid valve Up to 36 L/min (9.5 USgpm) 210 bar (3000 psi) SV9--E - Solenoid Valve -way, -position spool type solenoid valve Up to 6 L/min (9.5 USgpm) bar ( psi) () () (P) (T) In the de-energized position all ports are closed. When solenoid '' is energized flow

More information

Cartridge Valves. Proportional Valves Screw-in Cartridge Valves. Vickers. Maximum Pressure 280 bar (4000 psi) - Maximum Flow 160 l/min (42 USgpm)

Cartridge Valves. Proportional Valves Screw-in Cartridge Valves. Vickers. Maximum Pressure 280 bar (4000 psi) - Maximum Flow 160 l/min (42 USgpm) Vickers Cartridge Valves Proportional Valves Screw-in Cartridge Valves Maximum Pressure 8 bar (4 psi) - Maximum Flow 6 l/min (4 USgpm) Revised 7/ 76 Contents MODEL DESCRIPTION TYPICL PPLICTION PRESSURE

More information

Proportional Valves. Proportional solenoid valves for pressure and flow control B-1.A. An Eaton Brand

Proportional Valves. Proportional solenoid valves for pressure and flow control B-1.A. An Eaton Brand Proportional Valves Proportional solenoid valves for pressure and flow control An Eaton rand -.A Proportional Valves Valve Locator/Section Contents Note: Proportional valve solenoid coils and electronic

More information

Check valves Direct and pilot operated check valve functions for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm)

Check valves Direct and pilot operated check valve functions for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) Hydraulic Screw-in Cartridge Valves (SiCV) Check valves Direct and pilot operated check valve functions for applications up to 5 bar (5 psi) and 7 L/min (6 USgpm) Check valves CHECK VALVES... -4 FPR -

More information

Technical Reference. MCD manifold design guidelines, tooling, torque specifications, port and cavity dimensions

Technical Reference. MCD manifold design guidelines, tooling, torque specifications, port and cavity dimensions Technical Reference CD manifold design guidelines, tooling, torque specifications, port and cavity dimensions ETON Vickers Screw-in Cartridge Valves V-VLOV-C001-E1 June 2003 1 Section Contents Technical

More information

Solenoid Valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) A-1.

Solenoid Valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) A-1. Solenoid Valves Poppet and Spool type solenoid actuated valves for applications up to 5 bar (5 psi) and 7 L/min (6 USgpm) n Eaton Brand ETON Screw-In Cartridge Valves E-VLSC-MC-E November 9 -. Solenoid

More information

Logic elements. Differential pressure sensing elements for applications up to 350 bar (5000 psi) and 400 L/min (100 USgpm)

Logic elements. Differential pressure sensing elements for applications up to 350 bar (5000 psi) and 400 L/min (100 USgpm) Hydraulic Screw-in Cartridge Valves (SiCV) Logic elements Differential pressure sensing elements for applications up to 50 bar (5000 psi) and 400 L/min (00 USgpm) Logic elements LOGC ELEMENTS... -4 APPLCATON

More information

FLOW CONTROL VALVES A5-1 PN# / / ACC

FLOW CONTROL VALVES A5-1 PN# / / ACC FLOW CONTROL VLVES Flow Control Valves The HYDC family of flow control valves permit safe, simple and repeatable control of hydraulic fluids at operating pressures to psi. The standard slotted control

More information

Hydraulic Screw-in Cartridge Valves (SiCV) Proportional valves Proportional solenoid valves for pressure and flow control

Hydraulic Screw-in Cartridge Valves (SiCV) Proportional valves Proportional solenoid valves for pressure and flow control Hydraulic Screw-in Cartridge Valves (SiCV) Proportional valves Proportional solenoid valves for pressure and flow control Proportional valves PROPORTIONAL VALVES... - PFRH... -8 EPV...- EPV6...- EPV6A...-7

More information

Flow Control Valves. Overview. Accessories Catalog. Needle Valves. Flow Control Valves. Pressure Compensated Flow Control Valves.

Flow Control Valves. Overview. Accessories Catalog. Needle Valves. Flow Control Valves. Pressure Compensated Flow Control Valves. Overview Needle Valves DV, DVE & DVP Series (see page ) Flow Control Valves DRV & DRVP Series (see page ) Pressure Compensated Flow Control Valves SRVR Series (see page ) Check Valves RV & RVP Series (see

More information

DOUBLE, P.O. CHECK VALVES (PRE-ENGINEERED BLOCKS)

DOUBLE, P.O. CHECK VALVES (PRE-ENGINEERED BLOCKS) DOUBLE, P.O. CHECK VALVES (PRE-ENGINEERED BLOCKS) SERIES DOUBLE PILOT OPERATED CHECK VALVE... HS3 Page HD1 Page HD2 SERIES DOUBLE PILOT OPERATED CHECK VALVE GPM PSI LPM BAR CAVITY MODEL PAGE 5 3500 19

More information

Solenoid valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm)

Solenoid valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) Hydraulic Screw-in Cartridge Valves (SiCV) Solenoid valves Poppet and Spool type solenoid actuated valves for applications up to 5 bar (5 psi) and 7 L/min (6 USgpm) Solenoid valves SOLENOID VLVES...- SV5-8-C/CM

More information

Directional Controls

Directional Controls Vickers Directional Controls Mechanical ctuators Directional Control Valves Directional Control Valves 310 bar (4500 psi) Flows to 114 l/min (30 USgpm) NF D05, ISO-4401-05 DG1V4-01**-10 Knob Operated DG17V4-01**-10

More information

FEATURES SPECIFICATIONS

FEATURES SPECIFICATIONS RS 1 FETURES 2 3 1 High Pressure Viton Shaft Seal offers superior seal life and performance and eliminates the need for case drain. 2 Pressure Fed earing surface receives positive flow of clean, cool oil.

More information

High Pressure, High Flow Rate Modular Valves

High Pressure, High Flow Rate Modular Valves High Pressure, High Modular Valves EIC-F-14- MODULR VLVES The modular valves are functional elements with which a hydraulic system can be composed and built easily by stacking them with the mounting bolts.

More information

DT (700 Series) Hydraulic Motor

DT (700 Series) Hydraulic Motor DT (700 Series) Hydraulic Motor shafts 45 60mm Tapered 47 2-1/4 Straight 16.0 [.631] 15.9 [.629] 10.0 [.395] 9.9 [.391] 35 [1.37] 7 [.29] *120 [4.73] 70 [2.75] 38.9 [1.530] 37.6 [1.480] 12.7 [.501] 12.7

More information

Directional Control Valves

Directional Control Valves Overview HYDAC offers several functions of the Directional Control Cartridges. HYDAC Manually operated position, - way normally closed, spring return, directional valve features poppet design. It offers

More information

Pressure Relief Valves

Pressure Relief Valves VICKERS Pressure Relief Valves Unloading Relief Valves EURG1/2-06/10, 13 Design and EURT1/2-06/10, 12 Design Sectional Illustrations EURG* EURT* Basic Characteristics Mounting... Pipe or subplate mounting

More information

CVH103P. Check Valve Series CVH103P. Technical Information. General Description

CVH103P. Check Valve Series CVH103P. Technical Information. General Description Catalog HY-351/US Information Cartridge Style Valve. For additional information see Tips on pages 1-4. Valve Series H13P Spherical poppet for low leakage D -Ring eliminates back-up rings Dual sense paths

More information

Displacements cm 3 /r [in 3 /r] Design code [21.0] 400 [24.4] 434 [26.5] 480 [29.3] 677 [41.3] HP30 Motor

Displacements cm 3 /r [in 3 /r] Design code [21.0] 400 [24.4] 434 [26.5] 480 [29.3] 677 [41.3] HP30 Motor HP30 Motor Design code -003 Displacements cm 3 /r [in 3 /r] 344 [21.0] 400 [24.4] 434 [26.5] 480 [29.3] 677 [41.3] Engineered for performance For the past 55 years, Char-Lynn has been recognized as the

More information

* Optional PRESSURE COMPENSATOR - FLANGED TYPE B A X 2.2. Typical application VR5P with flow control valve

* Optional PRESSURE COMPENSATOR - FLANGED TYPE B A X 2.2. Typical application VR5P with flow control valve * Veljan 3 ports pressure compensator Valve are designed for improved operation safety and reduced mountg cost. These valves are used to mata a constant pressure drop External PD, External PP Internal

More information

RA / Pressure Reducing Valve, Pilot Operated Model DR (Series 5X) Ordering code 1/ PSI (350 bar) GPM (400 L/min)

RA / Pressure Reducing Valve, Pilot Operated Model DR (Series 5X) Ordering code 1/ PSI (350 bar) GPM (400 L/min) R 26 892/06.98 Pressure Reducing Valve, Pilot Operated Model DR (Series 5) Size 10 to 0... 5000 PSI (50 bar)... 105 GPM (400 L/min) R 26 892/06.98 Replaces: 05.94 Pilot operated pressure reducing valve

More information

PILOT OPERATED PRESSURE CONTROLS - FLANGED TYPE VR5 Series

PILOT OPERATED PRESSURE CONTROLS - FLANGED TYPE VR5 Series PILOT OPERTED PRESSURE CONTROLS FLNGED TPE VR5 Series Veljan Flanged type, Valves Series VR5V ( Relief ), VR5U (Unloader) and VR5S (Sequence ) are pilot controls. These range of valves are suitable for

More information

Kawasaki Motors Corp., U.S.A. Precision Machinery Division HMB 100. Staffa Fixed Displacement Hydraulic Motor

Kawasaki Motors Corp., U.S.A. Precision Machinery Division HMB 100. Staffa Fixed Displacement Hydraulic Motor Kawasaki Motors Corp., U.S.A. Precision Machinery Division HMB 100 Staffa Fixed Displacement Hydraulic Motor CONTENTS Page 1. General Description... 2 2. Functional Symbols... 2 3. Model Code... 3 4. Performance

More information

VALVES POWER TRANSMISSION T E C H N I C A L C A T A L O G

VALVES POWER TRANSMISSION T E C H N I C A L C A T A L O G VLVES POWER TRNSMISSION T E C H N I C L C T L O G Power transmission POCLIN HYDRULICS Methodology : This document is intended for manufacturers of machines that incorporate Poclain Hydraulics products.

More information

Vickers Counterbalance Valve. CB Series Mainfold Mounting 315 Bar SAE Flange Mounting L/min Subplate Mounting

Vickers Counterbalance Valve. CB Series Mainfold Mounting 315 Bar SAE Flange Mounting L/min Subplate Mounting Vickers Counterbalance Valve C Series ainfold ounting 315 ar SE Flange ounting 80-560 L/min Subplate ounting Table of Contents Counterbalance Valve General Description...2 Functional Symbols...2 odel Code...3

More information

Vickers. Service Data. Vane Pumps. Vane Type Triple Pump (F3) 2520VQSV10* ***** ******* 20* M 2492 S. Released

Vickers. Service Data. Vane Pumps. Vane Type Triple Pump (F3) 2520VQSV10* ***** ******* 20* M 2492 S. Released Service ata Vickers Vane Pumps Vane Type Triple Pump (F3) 2520VQSV10* ***** ******* 20* Released 08 01 95 M 2492 S 10 SE rated capacity (V10 cover end cartridge) USgpm Rotor Vane Kit Ring Pin Pin olt olt

More information

Vickers. Service Data. Vane Pumps. Vane Type Triple Pump (F3) 4525VQSV10* ***** ******* 20* Released M 2496 S

Vickers. Service Data. Vane Pumps. Vane Type Triple Pump (F3) 4525VQSV10* ***** ******* 20* Released M 2496 S Service ata Vickers Vane Pumps Vane Type Triple Pump (F3) 4525VQSV10* ***** ******* 20* Released 08 01 95 M 2496 S 10 SE rated capacity (V10 cover end cartridge) USgpm Rotor Vane Kit Ring Pin Pin olt olt

More information

Piston Accumulators Series Catalog HY /US Page

Piston Accumulators Series Catalog HY /US Page Page Series 5000 Series 5000 Piston ccumulators Heavy uty Service with 5000 PSI Operating Pressure 2" thru 9" ores with Over 30 Standard apacities Patented V-O-ring Piston Seals Serviceable Threaded End

More information

PILOT OPERATED PRESSURE RELIEF VALVE - Series VR4V

PILOT OPERATED PRESSURE RELIEF VALVE - Series VR4V PILOT OPERTED PRESSURE RELIEF VLVE - Series VR4V The Veljan Pressure Relief Valve series VR4V are pilot operated and work Internal Dra on the prciple of hydraulic balancg. These valves are used to limit

More information

Hydraulic Motor & Brake

Hydraulic Motor & Brake SERIES 500-501 - 510-511 - 520-521 - 530-531 - 50-51 - MEDIUM DUTY Hydraulic Motor & rake RE RE (ll Series) For Medium Duty pplications Overview series descriptions RE Series motors offer the perfect compromise

More information

Pressure Control Valves

Pressure Control Valves Control Valves DR8- Reducing/Relieving, Direct Acting, Spool Type 4 gpm (5 l/min) 6 psi (4 bar) Description A screw-in cartridge, direct acting, spool type, pressure reducing/relieving valve with internal

More information

Chapter 6: Check Valves

Chapter 6: Check Valves Contents Chapter : Check Valves Series Description Size Mounting Page Parker Standard DIN / ISO 1/8 1/4 3/8 1/2 3/4 1 0 10 1 25 32 Subplate Screw-in Slip-in Shuttle valves SSR -2 Check valves, direct operated

More information

Vickers. Piston Motors. Inline Piston Motors. Fixed and Variable Displacement. Revised 5/99 691

Vickers. Piston Motors. Inline Piston Motors. Fixed and Variable Displacement. Revised 5/99 691 Vickers Piston Motors Inline Piston Motors Fixed and Variable Displacement Revised 5/99 691 Table of Contents Introduction........................................................................................

More information

PVE 19 & 21 Piston Pumps

PVE 19 & 21 Piston Pumps Engineering PVE 19 & 21 Piston Pumps Pressures to 3500 psi For Mobile and Industrial Use Same Day Shipments Rated for 2400 rpm > Speeds to 2400 rpm www.fluidynefp.com Table of Contents Introduction...2

More information

9 Shaft type N = Metric, to DIN/ISO 3019, Part 2 and VDMA 24560, Part 1 Y = SAE models P*B5 to 15 only. Omit for 20 thru 90 models

9 Shaft type N = Metric, to DIN/ISO 3019, Part 2 and VDMA 24560, Part 1 Y = SAE models P*B5 to 15 only. Omit for 20 thru 90 models Model Codes P *** -(F)-(M) * *(F)(X) (*)-** -**-(C)-(G)-(L)- ** -**** 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 F V asic models = Fixed displacement type = Variable displacement type 2 Displacement PF and

More information

MOVICONTROL. Single and Double Fixed Vane Pumps SERIES V10, V20, 25V/VQ, 35V/VQ, 45V/VQ.

MOVICONTROL. Single and Double Fixed Vane Pumps SERIES V10, V20, 25V/VQ, 35V/VQ, 45V/VQ. Single and Double Fixed Vane Pumps SERIES V10, V20, 25V/VQ, 35V/VQ, 45V/VQ www.movicontrol.com.br V10/V20 Series Features Balanced vane type pumps are excellent for medium- to low-pressure mobile and industrial

More information

Vickers Pressure Relief Solenoid Operated, Two-Stage Directional Control Valve DG5S4-02 Flows to 115 l/min (30 USgpm) Pressure to 210 bar (3000 psi)

Vickers Pressure Relief Solenoid Operated, Two-Stage Directional Control Valve DG5S4-02 Flows to 115 l/min (30 USgpm) Pressure to 210 bar (3000 psi) Vickers Pressure Relief Solenoid Operated, Two-Stage Directional Control Valve DG5S4-02 Flows to 115 l/min (30 USgpm) Pressure to 210 bar (3000 psi) Revised 2/93 GB C 2037 Table of Contents Model Code...................................................................................................

More information

Piston Accumulators Series Catalog /USA Page

Piston Accumulators Series Catalog /USA Page atalog 1630-7/US Page Piston ccumulators Series 5000 Series 5000 Piston ccumulators Heavy uty Service with 5000 PSI Operating Pressure 2" thru 9" ores with Over 30 Standard apacities Patented V-O-ring

More information

PILOT OPERATED PRESSURE RELIEF VALVE - Series VR4V

PILOT OPERATED PRESSURE RELIEF VALVE - Series VR4V PILOT OPERTED PRESSURE RELIEF VLVE - Series VR4V The Veljan Pressure Relief Valve series VR4V are pilot operated and work Internal Dra on the prciple of hydraulic balancg. These valves are used to limit

More information

Kawasaki Motors Corp., U.S.A. Precision Machinery Division HMC 045. Staffa Fixed Displacement Hydraulic Motor

Kawasaki Motors Corp., U.S.A. Precision Machinery Division HMC 045. Staffa Fixed Displacement Hydraulic Motor Kawasaki Motors Corp., U.S.A. Precision Machinery Division HMC 045 Staffa Fixed Displacement Hydraulic Motor CONTENTS Page 1. General Description... 2 2. Functional Symbols... 2 3. Model Code... 3 4. Performance

More information

Low Speed, High Torque Motors

Low Speed, High Torque Motors Low Speed, High Torque Motors Spool Valve: J, H, S, T, and W Series Disc Valve: 2,000, 4,000 Compact, Delta, 4,000, 6,000, and 10,000 Series VIS: VIS 30, VIS 40, and VIS 45 Series Contents SECTION PRODUCT

More information

Group 1 Gear Pumps Technical Information General Information

Group 1 Gear Pumps Technical Information General Information General Information OVERVIEW The Sauer-Danfoss Group is a range of peak performance fixed-displacement gear pumps. Constructed of a high-strength extruded aluminum body with aluminum cover and flange,

More information

Kawasaki Motors Corp., U.S.A. Precision Machinery Division HMB 325. Staffa Fixed Displacement Hydraulic Motor

Kawasaki Motors Corp., U.S.A. Precision Machinery Division HMB 325. Staffa Fixed Displacement Hydraulic Motor Kawasaki Motors Corp., U.S.A. Precision Machinery Division HMB 325 Staffa Fixed Displacement Hydraulic Motor CONTENTS Page 1. General Description... 2 2. Functional Symbols... 2 3. Model Code... 3 4. Performance

More information

Double Pump Operating Specifications

Double Pump Operating Specifications Double Pump Operating Specifications Shaft End Pump Cover End Pump Typical Typical Typical Typical del. input del. input Delivery L/min kw Delivery L/min kw USgpm @ (USgpm) (hp) USgpm @ (USgpm) (hp) 12

More information

Disc Valve Hydraulic Motors 2000 Series

Disc Valve Hydraulic Motors 2000 Series Disc Valve Hydraulic Motors 10.2014 inspired hydraulics. Änderungen und Druckfehler vorbehalten 10.2014 EN EATON_Motoren english Highlights Port A Features Three zone design for longer life and true bi-directionality.

More information

Solutions. We Manufacture. H y d r a u l i c s. Eaton Medium Duty Piston Pump. h y d r a u l i c s

Solutions. We Manufacture. H y d r a u l i c s. Eaton Medium Duty Piston Pump. h y d r a u l i c s H y d r a u l i c s ydraulics Eaton Medium Duty Piston Pump h y d r a u l i c s Model 70122, 70422, 70423, and 70523 or -Flow Compensated Piston Pumps We Manufacture April 1997 Solutions S o l u t i o

More information

Check Valves. VC Series - Cartridge Mounting 500 Bar. Innovative Fluid Power. Bulletin 86624

Check Valves. VC Series - Cartridge Mounting 500 Bar. Innovative Fluid Power. Bulletin 86624 VC Series - Cartridge Mounting 500 ar Innovative Fluid Power ulletin 86624 Issue 1.0 02.2010 VCC 500 ar General Information Check Valve with Standard Top Cap Section View with Standard Poppet Maximum Working

More information

CHECK VALVE - DIRECT OPERATED - Series VC4V SPECIFICATIONS PERFORMANCE CURVES VC4V03 VC4V10 VC4V06

CHECK VALVE - DIRECT OPERATED - Series VC4V SPECIFICATIONS PERFORMANCE CURVES VC4V03 VC4V10 VC4V06 CHECK VLVE - DIRECT OPERTED - Series VV Veljan Direct operated Check Valve Series VV are poppet type and designed for a maximum pressure of 35 bar and a flow capacity rangg from 18 l/m for a 3/8 valve

More information

Eaton Char-Lynn Low Speed, High Torque Motors. Orbit motor

Eaton Char-Lynn Low Speed, High Torque Motors. Orbit motor Eaton Char-Lynn Low Speed, High Torque Motors Orbit motor Table of Contents Description Page No. H & S Series 3 Features 3 Model code 3 H Series 4-9 Specifications 4 Performance 5 Dimensions and mount

More information

V 20 F - 1 P 13 S - 1 A 8H 22 L. Std. cover. 1/2 NPT thd. (V10 only) 3/4 NPT thd. (V20 only) 3/4-16 St. thd. (V10F & V20F) 3/4 16. St. thd.

V 20 F - 1 P 13 S - 1 A 8H 22 L. Std. cover. 1/2 NPT thd. (V10 only) 3/4 NPT thd. (V20 only) 3/4-16 St. thd. (V10F & V20F) 3/4 16. St. thd. Model Codes V 2 F - 1 P 13 S - 1 8H 22 L 1 2 3 4 5 6 7 8 9 1 11 12 1 Vane pump 2 Series 1 or 2 3 Integral valve options (Omit if not required) F Flow control & relief P Priority valve & relief 4 Mounting

More information

Accessories. Subplates and Connection Plates for Four-Port Directional Valves. Vickers. ISO 4401, 02/03/05/07/08 General Description.

Accessories. Subplates and Connection Plates for Four-Port Directional Valves. Vickers. ISO 4401, 02/03/05/07/08 General Description. Vickers ccessories Subplates and Connection lates for Four-ort Directional Valves ISO 4401, 02/03/05/07/08 General Description his range of subplates and auxiliary connection plates offers an economical

More information

BW0511FP. ByWire Elements BW0511FP Flow Sharing Element Interface IBW0511

BW0511FP. ByWire Elements BW0511FP Flow Sharing Element Interface IBW0511 ywire Elements Flow Sharing Element Interface IW05 efore use, carefully read the GENERL INSTRUCTIONS FOR USE OF DIRECTIONL CONTROL VLVES Technical data Nominal flow Nominal pressure 35 l/min - P=8 bar

More information

Differential Proportional Flow Control Valve DPCMEE 16 & 20

Differential Proportional Flow Control Valve DPCMEE 16 & 20 Differential Proportional Flow Control Valve DPCMEE 6 & 2 Table of Contents Designation Symbol Page General Description and Operating Principle 4 Specifications 5 Performance Data DPCMEE6 - CK; EK and

More information

RE / Check-Q-meter type FD, series 2X. Ordering details FD 2X / V * Symbols 1/8. Replaces: 03.92

RE / Check-Q-meter type FD, series 2X. Ordering details FD 2X / V * Symbols 1/8. Replaces: 03.92 RE 1/09.9 1/03.9 Check-Q-meter type FD, series Sizes 1, 1,, 3 Up to 0 L/min Up to 30 bar RE 1/09.9 Replaces: 03.9 Features: For installation in manifolds (cartridge valve), With SE flanged ports, For sub-plate

More information

Kawasaki Motors Corp., U.S.A. Precision Machinery Division. Staffa Fixed Displacement Hydraulic Motor

Kawasaki Motors Corp., U.S.A. Precision Machinery Division. Staffa Fixed Displacement Hydraulic Motor Kawasaki Motors Corp., U.S.A. Precision Machinery Division HM(HD)B 270 Staffa Fixed Displacement Hydraulic Motor CONTENTS Page 1. General Description... 2 2. Functional Symbols... 2 3. Model Code... 3

More information

white drive products SERIES HYDRAULIC MOTORS

white drive products SERIES HYDRAULIC MOTORS white drive products WR SERIES HYDRULIC MOTORS WR overview The WR Series motor incorporates the latest advances for smooth performance, efficiency and durability. It features an optimized Roller Stator

More information

Catalog HY /NA. Catalog HY /NA. Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA

Catalog HY /NA. Catalog HY /NA. Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA Catalog HY28-6/NA PV, PVT Series Piston Pumps Variable Volume Catalog HY28-6/NA 1 Catalog HY28-6/NA Notes Series PV 2 Catalog HY28-6/NA Introduction Series PV Quick Reference Data Chart Pump Delivery Approx.

More information

Solutions. We Manufacture. i Hydraulics. Eaton. Variable Displacement Piston Pump. Manual Controlled

Solutions. We Manufacture. i Hydraulics. Eaton. Variable Displacement Piston Pump. Manual Controlled Eaton s y c h Variable Displacement Piston Pump i Hydraulics d r Manual Controlled l a Model 70160 20, cm/r [1.24 in/r] 2,6 cm/r [1.44 in/r] u u l Model 7060 40,6 cm/r [2.48 in/r] 49,2 cm/r [.00 in/r]

More information

Proportional Valves. Auxiliary Function Modules for Proportional Valves. Hydrostat, Parallel-Flow-Path, Pilot Shuttle and Tapping Modules

Proportional Valves. Auxiliary Function Modules for Proportional Valves. Hydrostat, Parallel-Flow-Path, Pilot Shuttle and Tapping Modules June 1996 G-459 VICKERS roportional Valves uxiliary Function Modules for roportional Valves Hydrostat, arallel-flow-ath, ilot Shuttle and Tapping Modules Functional Symbols For typical applications of

More information

VJO1-06/S. Functional Description HA /2010. Check Valves. Replaces HA /2008. Size to 06 (1/4) bar (4600 PSI)...20 L/min (5.

VJO1-06/S. Functional Description HA /2010. Check Valves. Replaces HA /2008. Size to 06 (1/4) bar (4600 PSI)...20 L/min (5. Check Valves VJO1-06/S Size to 06 (1/4)...320 bar (4600 PSI)...20 L/min (5.3 GPM) HA 5004 11/2010 Replaces HA 5004 4/2008 Small dimensions Two models Poppet design Leak-free closure in one direction VJO1-06/Sx-1

More information

Chapter 6: Check Valves

Chapter 6: Check Valves Contents Chapter : Check Valves Series Description Size Mounting Page Parker Standard DIN / ISO 1/8 1/4 3/8 1/2 3/4 1 0 10 1 25 32 Subplate Screw-in Slip-in SSR RK / RB CS SPZBE SPV / SPZ C4V CPS C4V D4S

More information

Variable Displacement Piston Pumps. Performance Information. Features. Specifications. Controls. Schematic Symbol (Basic Pump) Weight and Package Size

Variable Displacement Piston Pumps. Performance Information. Features. Specifications. Controls. Schematic Symbol (Basic Pump) Weight and Package Size Catalog HY13-1552-2/US Technical Information Series PVC65 Performance Information Series PVC65 Compensated, Variable Volume, Piston Pump Features High Strength Cast-Iron Housing uilt-in Supercharger High

More information

Series PHP10 Variable Volume, Piston Pumps

Series PHP10 Variable Volume, Piston Pumps Catalog HY13-1553-1/N,EU Series PHP1 Series PHP1 Variable Volume, Piston Pumps Bulletin 2-18/US 123 Catalog HY13-1553-1/N,EU Series PHP1 Performance Information Series PHP1 Pressure Compensated, Variable

More information

PILOT OPERATED SEQUENCE VALVE - Series VR4S

PILOT OPERATED SEQUENCE VALVE - Series VR4S PILOT OPERTED SEQUENCE VLVE - Series VRS Veljan Sequence Valve Series VRS are pilot operated controls and enable a hydraulic system to operate a sequence. Fluid is allowed to pass to a secondary system

More information

Proportional Electro-Hydraulic Flow Control and Relief Valves

Proportional Electro-Hydraulic Flow Control and Relief Valves Ω Ω Proportional Electro-ydraulic Flow ontrol and Relief Valves This flow control and relief valve is an energy-saving valve that supplies the minimum pressure and flow necessary for actuator drive. Since

More information

Eaton. Revised June, Heavy Duty Hydrostatic Transmissions. l r. Models 33 through 76 Hydrostatic Transmissions. We Manufacture.

Eaton. Revised June, Heavy Duty Hydrostatic Transmissions. l r. Models 33 through 76 Hydrostatic Transmissions. We Manufacture. s Eaton Revised June, 1997 c Heavy Duty Hydrostatic Transmissions h i y d l ydraulics r a u u l c a i r s y d Models 33 through 76 Hydrostatic Transmissions We Manufacture Solutions H S o l u t i o n s

More information

YMSY. Advanced design in disc distribution flow,which can automatically compensate in operating with high volume efficiency and long life.

YMSY. Advanced design in disc distribution flow,which can automatically compensate in operating with high volume efficiency and long life. The series motors adapts an advanced ROLLER gear set designed with disc distribution flow and high pressure. This motor series uses the ROTOR gear type manufactured with most advanced technology and quality

More information

VALVES FOR HYDRAULIC MOTORS

VALVES FOR HYDRAULIC MOTORS VLVES FOR HYDRULI OTORS OVERENTER VLVES WITH RKE ONTROL Single Overcenter Valves with rake ontrol type KP...E Single Overcenter Valves with rake ontrol type KP...E SPEIFITION DT Dual Overcenter Valves

More information

2.3 MEDIUM HEAVY DUTY SERIES

2.3 MEDIUM HEAVY DUTY SERIES 2 2.3 MEDIUM HEAVY DUTY SERIES CONTENTS PPV11 Ordering Code 2.3.1 Medium Heavy Duty Series 2.3.2 Torque limiter settings Technical Information 2.3.3 Specifications 2.3.4 Hydraulic fluids 2.3.5 Viscosity

More information

VJL Functional Description. Ordering Code VJL Spare Parts HA /2002. Logical 3-way check valves. Replaces HA /2001

VJL Functional Description. Ordering Code VJL Spare Parts HA /2002. Logical 3-way check valves. Replaces HA /2001 Logical 3-way check valves VJL2-304 HA 5007 3/2002 Size 04 p max up to 210 bar Q max up to 15 L/min Replaces HA 5007 6/2001 Screw-in cartridge valve For leak-free applications Simple design High reliability

More information

Hydrokraft Transmission Closed Loop Piston Pumps

Hydrokraft Transmission Closed Loop Piston Pumps Hydrokraft Transmission Closed Loop Piston Pumps Technical Catalog TVX Table of Contents Introduction....................................................................... 4 Model Codes Form Page.....................................................................

More information

Series PVP Variable Volume, Piston Pumps

Series PVP Variable Volume, Piston Pumps Catalog HY13-1553-1/N,EU Series PVP Variable Volume, Piston Pumps Catalog 26-12-1/US hpm12-1.p65, lw, jk 57 Catalog HY13-1553-1/N,EU hpm12-1.p65, lw, jk 58 Catalog HY13-1553-1/N,EU Introduction Series

More information

03 SERIES. General Information Mounting Surface : ISO 4401-AC-05-4-A, CETOP-5, NFPA-DO2 Up to 25 MPa (3630 PSI), 70 L /min (18.5 U.S.

03 SERIES. General Information Mounting Surface : ISO 4401-AC-05-4-A, CETOP-5, NFPA-DO2 Up to 25 MPa (3630 PSI), 70 L /min (18.5 U.S. 3 SERIES General Information Mounting Surface : ISO 44-C--4-, CETO-, N-DO Up to Ma (363 SI), 7 L /min (8. U.S.GM) ub. EC-43 MODULR VLVES The modular valves are functional elements with which a hydraulic

More information

Piston Accumulators Series Catalog HY /US

Piston Accumulators Series Catalog HY /US Series 3000 Series 3000 Heavy uty Service with 3000 PSI Operating Pressure 2" thru 12" ores with Over 50 Standard apacities Patented V-O-ring Piston Seals Serviceable Threaded End onstruction Five Standard

More information

10 SERIES MODULAR VALVES. Pub. EC-1405

10 SERIES MODULAR VALVES. Pub. EC-1405 SERIES General Information Mounting Surface : ISO ----, CETOP-, NP-D Up to 5 MPa (363 PSI), 8 L /m in ( U.S.GPM) Pub. EC-5 The modular valves are functional elements with which a hydraulic system can be

More information

Bladder Accumulators za03 Bottom Repairable Top Repairable Medium Flow High Flow Transfer Barrier Gas Bottle

Bladder Accumulators za03 Bottom Repairable Top Repairable Medium Flow High Flow Transfer Barrier Gas Bottle LADDER PRODUCTS za03 ottom Repairable Top Repairable Medium Flow High Flow Transfer arrier Gas ottle Features: Operating Pressures to 6600 PSI Ten Different Capacities from 10 cu in to 15 gallons Nine

More information

Directional Controls

Directional Controls Vickers Directional Controls Pilot Operated Directional Control Valves DG5S4-10**-53 DG4S4-01-50 Air Gap Pilot Valve DG5S4-10**-80 DG4S4-01-60 Wet Armature Pilot Valve DG5S4-10** -90 DG4V-3S-60 Pilot Valve

More information

Table of Contents. H Series Variable Displacement Piston Pumps

Table of Contents. H Series Variable Displacement Piston Pumps Table of Contents H Series Variable Displacement Piston Pumps Principles of Operation....................................................................................3 Hydraulic System Design Calculations........................................................................4

More information

Directional Controls

Directional Controls VICKERS Directional Controls Solenoid Operated Directional Control Valves NF D05, ISO-4401-05 DG4S*-01**-5* ir Gap ype Revised 8/97 671 able of Contents DG4S*-01 Model Code..................................................................................

More information

ISO 4401 size 07; 315 bar (4500 psi); up to 200 L/min (53 USgpm) General Description

ISO 4401 size 07; 315 bar (4500 psi); up to 200 L/min (53 USgpm) General Description Vickers SystemStak SystemStak Valves ISO 441 size 7; 315 bar (45 psi); up to 2 L/min (53 USgpm) General Description This range of stackable hydraulic controls are designed to be mounted under a size 7

More information

Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI

Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI Catalog HY15-352/US Contents SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI PRESSURE RELIEVING AP1B2YP... 2G... Increase /Increase Current...5.3/1.4... 35/5... 7-8 AP2B2YP... C8-2...

More information

Proportional Electro-Hydraulic Relieving and Reducing Valves

Proportional Electro-Hydraulic Relieving and Reducing Valves These valves consist of a small size but high performance EH series electro-hydraulic proportional pilot relief valve and reducing valve with relief function. The valves control the system pressure proportionally

More information

CROSS HYDRAULICS PTY LTD SECTION

CROSS HYDRAULICS PTY LTD SECTION OVERVIEW The motor series is an economical alternative to more complex geroler designs that still provides high efficiency across a wide performance range. These motors are intended for medium-duty applications

More information

whitedriveproducts SERIES Hydraulic Motor LIGHT DUTY

whitedriveproducts SERIES Hydraulic Motor LIGHT DUTY SERIES 0-1 - LIHT DUTY Hydraulic Motor RS RS (ll Series) For Light Duty pplications Overview RS Series motors are the most economical model in the White Drive Products product line, but are not low-tech.

More information

Solutions. ydraulics. We Manufacture. H y d r a u l i c s. Eaton. h y d r a u l i c s. Variable Displacement Piston Pump.

Solutions. ydraulics. We Manufacture. H y d r a u l i c s. Eaton. h y d r a u l i c s. Variable Displacement Piston Pump. H y d r a u l i c s ydraulics Eaton h y d r a u l i c s Variable Displacement Piston Pump Manual Controlled Servo Controlled We Manufacture Model 70160 20, cm /r [1.24 in /r] 2,6 cm /r [1.44 in /r] Model

More information

Pressure: Max working 420 bar (6000 psi) (acc. to NFPA T ) Burst 1260 bar (18300 psi) (acc. to NFPA T )

Pressure: Max working 420 bar (6000 psi) (acc. to NFPA T ) Burst 1260 bar (18300 psi) (acc. to NFPA T ) HYDRULIC FILTRTION In line high pressure filters Technical Information Pressure: Max working 420 bar (6000 psi) (acc. to NFP T 3.10.5.1) Burst 1260 bar (18300 psi) (acc. to NFP T 3.10.5.1) Housing Connection

More information

Pilot Operated Flow Control Valves / Pilot Operated Flow Control and Check Valves

Pilot Operated Flow Control Valves / Pilot Operated Flow Control and Check Valves FLOW CONTROLS Flow control of these valves is continuously made by a hydraulically operated pilot piston mechanism which controls opening area of the orifice of the valve. With the use of these valves,

More information

PILOT OPERATED PRESSURE RELIEF VALVE SERIES - IN-LINE MOUNTING

PILOT OPERATED PRESSURE RELIEF VALVE SERIES - IN-LINE MOUNTING CONTINENTL HYDRULICS PR*W - PR*WU PILOT OPERTED PRESSURE RELIEF VLVE SERIES - IN-LINE MOUNTING 5505 WEST 123RD STREET SVGE, MN 55378-1299 / PH: 952.895.6400 / WWW.CONTINENTLHYDRULICS.COM PRECISE PR*W -

More information

Spool & Sleeve Valves for ANSI Sub-Bases Series W70

Spool & Sleeve Valves for ANSI Sub-Bases Series W70 Spool & Sleeve Valves for NSI Sub-ases Series W70 5/ Valves Single Direct Solenoid, Spring Return NSI Range of Valve Model vg. Dimensions mm Weight kg 1 G 1/ - W7016331 0.9 177 50 58 1.6.5 - G 1/ W70163331.

More information

FEATURES SPECIFICATIONS

FEATURES SPECIFICATIONS FETURES 1 Heavy-Duty Drive Link is up to 30% stronger than competitive designs for longer life. 1 2 3 H 2 Three-Zone Orbiting Valve precisely meters oil to produce exceptional volumetric efficiency. 3

More information

06 SERIES MODULAR VALVES. Pub. EC-1404

06 SERIES MODULAR VALVES. Pub. EC-1404 6 SERIES General Information Mounting Surface : ISO -AE-8--A, CETOP-8, NPA-D6 Up to 5 MPa (363 PSI), 5 L /m in (3 U.S.GPM) Pub. EC- The modular valves are functional elements with which a hydraulic system

More information

Vickers. Proportional Valves. EPV16 Series Valvistor Proportional Flow Controls

Vickers. Proportional Valves. EPV16 Series Valvistor Proportional Flow Controls Vickers Proportional Valves EPV6 Series Valvistor Proportional Flow Controls Vickers, Incorporated, 998 All rights reserved Features and Benefits The EPV (Electro Proportional Valve) series of poppet valves

More information

RA / Accumulator unloading valve, pilot operated, Model DA 6 V.., series 4X. Ordering details DA 6 V 4X. Preferred models 1/8.

RA / Accumulator unloading valve, pilot operated, Model DA 6 V.., series 4X. Ordering details DA 6 V 4X. Preferred models 1/8. R 26 404/06.9 ccumulator unloading valve, pilot operated, Model D 6 V.., series 4X Size 6 up to 4500 SI (315 bar) up to.00 GM (30 L/min) R 26 404/04.9 Features: For subplate mounting: porting pattern to

More information

Mobile Valves Proportional - Load Sensing

Mobile Valves Proportional - Load Sensing Mobile Valves Proportional - Load Sensing Model CML60 325 bar 60 L/min Up to 8 sections Eaton F(x) Compliant Table of Contents General Information... 3 Model Code Valve Section... 4 Valve Assembly... 5

More information

VHO Vane Pumps ENGINEERING DATA. Single, Double, Triple & Thru Drive Available Multiple Displacements Low Cost Alternative Proven Performance

VHO Vane Pumps ENGINEERING DATA. Single, Double, Triple & Thru Drive Available Multiple Displacements Low Cost Alternative Proven Performance ENGINEERING DATA VHO Vane Pumps Single, Double, Triple & Thru Drive Available Multiple Displacements Low Cost Alternative Proven Performance www.fluidynefp.com Table of Contents Performance Data...2 Model

More information

IFP VTM42 POWER STEERING PUMPS

IFP VTM42 POWER STEERING PUMPS IFP VTM42 POWER STEERING PUMPS * Compact Power Source for Steering Assemblies * Integral Relief and Flow Control * High Efficiency * Balanced Cartridge Design * Quiet Operation IFP Power Steering Pump

More information

Vickers. Vane Pumps. V Series - Low Noise Vane Pumps High Performance Intravane Pumps For Industrial Applications.

Vickers. Vane Pumps. V Series - Low Noise Vane Pumps High Performance Intravane Pumps For Industrial Applications. Vickers Vane Pumps V Series - Low Noise Vane Pumps High Performance Intravane Pumps For Industrial Applications Revised 6/95 560 Introduction Vickers offers the most complete line of hydraulic intravane

More information