GmbH Lufttechnik Dresden. User information RADIAL FAN SERIES VRE direct-driven. Edition 11/17

Size: px
Start display at page:

Download "GmbH Lufttechnik Dresden. User information RADIAL FAN SERIES VRE direct-driven. Edition 11/17"

Transcription

1 GmbH Lufttechnik Dresden User information RADIAL FAN SERIES VRE 0 direct-driven Edition 11/17

2 series VRE 0 direct-driven For use in all areas of ventilation technology High chemical resistance through use of plastics (PVC, PPs, PE, PVDF, GFRP, electrically conductive plastics) High efficiency and low noise emission Volumetric flow rate Pressure increase up to 145,000 m3/h up to 6, Pa Performance scaling using 14 sizes and 4 impeller types Casing position L and R Explosion protected models in accordance with Directive 2014/34/EU (ATEX) Versatile casing connections Extensive range of ventilation and electrical accessories We reserve the right to change the technical data in this brochure without notice The data are binding only after written confirmation from the manufacturer

3 Series VRE direct-driven Technical explanation Base Intake connector Impeller Motor Flexible connection with tightening strap Hub protection cap Impeller fastener Motor mount Adaptor ring Condensate drain Casing Vibration isolators APPLICATION Radial fans of the series VRE have a high corrosion resistance thanks to their use of high-grade plastics and are thus preferred for applications such as fume extraction of process gases in the chemical/pharmaceutical industry as well as ventilation of laboratories, battery rooms, pickling baths, scrubbers, electroplating units and agricultural facilities, etc TECHNICAL DESCRIPTION The fans main components are the impeller, spiral casing, casing connections, base and drive motor The motor is directly flanged horizontally onto the base and is completely separate from the flow The impeller sits on the motor shaft and is driven directly Steel parts such as screws, hub and hub connection are protected from corrosion by means of plastic covers or, alternatively, resistant steel is used The aerodynamic placement of the fans is state of the art and thus achieves high efficiency, low noise emissions and high power density Every fan is delivered as a complete ready-to-use assembly unit Vibration isolators adjusted in size and numbers, elastic connections on the pressure and suction sides and a condensate well are included in the standard scope of delivery Design characteristics Impeller: To cover a large performance spectrum, there are four impeller versions: Type 731 with backward curved vanes Type 733 with backward curved vanes Type 734 with forward curved vanes Type 673 with backward curved vanes Special impellers are used for special applications For example, impellers with radially arranged vanes are advantageous if the medium to be conveyed contains strongly adhesive substances The impellers are manufactured using modern joining technologies; dynamic balancing takes place in accordance with ISO 19 Materials: PVC, PPs, PVDF, GFRP (for strict requirements), electrically conductive plastics (EX fans) Casing: The casings are welded together tightly using deep-drawn half shells (size 2 made of PVC or PPs) or straight side walls and a jacket The suction side connection diameter is always identical to the nominal size of the fan You can open the casing on the suction side for cleaning There is always a condensate drain at the lowest point The shaft passage is sealed sufficiently for many applications by means of the back side vanes on the impeller In case of higher sealing requirements, an additional seal is used on the impeller/casing (see SHAFT SEAL section p 04) In case of high security requirements splinter protection or additional GFRP reinforcement is necessary A wide range of casing connections is available for connecting ventilation ducts Caution! Connected system components must not exert any mechanical loads on the fan Materials: PVC, PPs, PP, PE, PVDF, GFRP (see special designs, p 66), Electrically conductive plastics PEX, PPsX, GFRPX (EX fans) Base: stable welded structure made of steel panels; galvanised or varnished depending on the size; can be supplied in stainless steel on request Motors: Standard motor: 3~V/Hz, protection level IP54, type B5 (in special cases B14 or B3) Single phase motors 2V/Hz, motors with special voltages and a different level of protection Pole-changing and explosion protected motors Motors with thermal winding protection (PTC thermistor) --> special design TS Motors with integrated frequency converter --> special design MFU 03

4 Series VRE direct-driven Technical explanation OPERATING CONDITIONS perm ambient temperature: - C C (for EX motors -20 C C ) perm temperature of medium: - C C Higher temperatures are only permissible for certain sizes, materials and rotation speeds and only after consultation with the manufacturer The materials used feature high resistance to many chemical substances Nevertheless, even plastic materials are susceptible to attack by certain chemical substances The following factors play a role here: Chemical composition and concentration of the conveyed medium Temperature and exposure time Mechanical load and residual tension from processing In many application fields, eg in laboratories, chemical stores, agricultural facilities and moisture-laden processes, good experience has been made with "standard materials" such as PVC or PPS, which can generally be used without problems Critical applications include process engineering fields such as surface finishing, pickling units, process exhaust air in microelectronics etc In order to select the most suitable material, the intended use of the fan and the type of medium must always be stated in requests for quotation or orders Media containing small amounts of dust particles can also be conveyed; however increased wear is to be expected Note regarding outdoor use: Avoid exposing the fan to intensive UV radiation Plan weather protection for the motor Consider ambient conditions when selecting materials Work area: The fans work stably in the entire area of the depicted characteristic Operation at lower flow rates is permissible but very uneconomical Use at higher flow rates may overload the motor (in particular with type 734) and must be avoided Parallel connection: always possible for type 731, but only in consultation with the manufacturer for type 734 Series connection: only permissible after consultation with the manufacture (increased casing pressure) SHAFT SEAL By default, the VRE radial fans are equipped with rear vanes mounted to the rear hub cap This ensures that outside air is constantly drawn in via the minimised gap on the shaft passage if the suction side loss of pressure is larger than 1/3 of the overall loss of pressure Hence, you should always try to arrange components with high losses of pressure such as washers, filters, eliminators etc before the fan, ie on the suction side Casing wall Impeller hub Sealing ring Mating surface Radial disc Genügt diese "Aerodynamische Gehäuseabdichtung" nicht, zb wenn die Gefahr besteht, dass bei Stillstand aggressives Gas austreten kann, so wird eine Wellendichtung eingesetzt Bei der Sonderausführung GD wird ein Dichtring mit einer axial wirkenden flexiblen Dichtlippe auf dem Nabenkörper befestigt Die in die Gehäusewand eingesetzte Gegenlauffläche besteht aus einem Werkstoff mit guten Gleiteigenschaften (Edelstahl oder zb bei Einwirkung von Salzsäure, Chromsäure, Flußsäure usw aus einem speziellen Kunststoff) Diese Dichtung wird bei hohen Forderungen an die Gasdichtheit und bei relativ trockener Abluft verwendet und zeichnet sich durch eine hohe Standfestigkeit aus In case of very high sealing requirements, in particular when there is a lot of humidity or condensate, there are various special seals such as sealing gas seals, labyrinth seals etc Please consult the manufacturer in relation to this SPECIAL DESIGNS and ACCESSORIES (for more information, see p 67 of this brochure) Cleaning hatch, splinter protection, weather protection for the motor, additional connections for condensate drain, stainless steel base, suction and blow out protection grids, Air conducting parts: Electric accessories: Pipes, ducts, arches, dampers, exhaust air hoods etc, pipe and splitter attenuators, Repair switch, motor protection switch, pole switch, complete fan controls, frequency converter (also with pressure and volumetric flow control); air-flow monitor 04

5 Series VRE direct-driven Technical explanation EXPLOSION PROTECTION Directive 2014/34/EU (ATEX) re-regulates explosion protection for non-electrical devices as of 29/03/2014 Aside from complying with design and safety regulations as per DIN EN and DIN EN 13463, the fan must be assigned to the respective protection type and be marked accordingly The manufacturer must provide proof of compliance Explosion hazard areas are found in the chemical industry, gasworks, coking plants, painting facilities, fuelling stations, sewage treatment plants, and laboratories, etc Requirements for an explosion are flammable substance (eg gas, dust) sufficient oxygen (air) source of ignition (sparks, fire, hot surfaces, electrostatic discharge) The following measures must be implemented in areas with a potential explosion hazard: An explosive atmosphere is prevented from developing Avoidance of sources of ignition Measures to weaken the deleterious effects of an explosion In many cases, an efficient and monitored ventilation system is sufficient to prevent the formation of an ignitable atmosphere and thus an explosion hazard The protection requirements for a fan are based on the probability of occurrence of an explosive atmosphere in the medium and/or the environment There are three types of explosion hazard zone: Occasional Zone 1 that are likely to occur 2 frequently Only rarely and Zone 2 During routine operation 3 briefly Which protection is required and the additional requirements to be observed is the responsibility of the system operator or the relevant supervisory authority This means that the customer's order must specify the protection the fan is to have The VRE fans are supplied for the following ignition protection types: Zone 1: Zone 2: Explosion hazard Continuous or long-term II 2G c IIB+H2 T3 II 3G c IIB+H2 T3 Hazard zone Avoidance of sources of ignition Category acc to ATEX Zone 0 that are very unlikely to 1 occur Temperature class T3 (ignition temperature of the gas > C ) Explosion group of gases IIB+H2 (IIA and H 2 included, but not IIC) Design safety Device category (3G = gases of zone 2) Device group II (use in the mining area not permitted) Use in Zone 0 is not possible as a matter of principle Gases of explosion group IIC (except hydrogen), gases with an ignition temperature below C as well as flammable dusts are also excluded In the rating, the internal (medium conveyed) and external (environment) areas are distinguished in general Depending on the hazard zone, certain design variants are prescribed Explosion protected devices (motors, switches etc) are used and electrically conductive plastics (preferably conductive and flame retardant polypropylene --> PPsX) Basically, this results in the following ratings: Hazard zone MIETZSCH Motor Impeller/casing inside outside Designation without converter with converter material Zone 2 Zone 2 Z2Z2 EEx e II EEx de not conductive Zone 2 none Z2Z3 EEx e II Standard not conductive Zone 1 Zone 1 Z1Z1 EEx e II EEx de conductive Zone 1 Zone 2 Z1Z2 EEx e II EEx de conductive Special requirements for operation on the frequency converter Motors with increased safety EEx e II are not approved for converter operation: Pressure-resistant encapsulated EEx de motors can run on the converter if they are equipped with special winding protection (special design TS15) If there is no EX zone on the outside and the fan meets certain design requirements, standard motors may also be used which can then also be operated with a converter 05

6 Series VRE direct-driven Technical explanation EXPLANATIONS REGARDING THE TYPE DESIGNATION VRE 2 / 731 W 14 - TS - GD - 0 L - PE/PPs Fan (radial, single-sided suction) Nominal size (suction diameter/mm) Impeller type curved backwards curved backwards curved forwards curved backwards (Other impeller types are also possible as a special design) Direct drive Rated speed rpm (higher speed for pole changing motors) Short designation of the special designs E = single-phase operation TS = with thermal winding protection (PTC thermistor) P1 = pole-changing motor with rpm halving (Dahlander) eg 1,4 P1 = 1,4/ rpm P2 = pole-changing motor with separate winding eg 1,4 P2 = 1,4/9 rpm (switch to next lower rpm) EX = with explosion protected motor EEx e II T3 EXde = with explosion protected motor EEx de IIC T4 ZiZo = ex protected fan for zone i=inside and o=outside eg Z1Z2 = inside zone 1 and outside zone 2 GD = gastight, shaft passage technically gastight GDS = high casing tightness with humid exhaust air DD = triangular motor fastening for converter operation at 3x2V (with mounted repair switch) Casing position/direction of rotation (when looking at intake socket) Material (casing/impeller) PERFORMANCE PARAMETERS All performance parameters are determined on MIETZSCH s test bench The setup complies with DIN EN ISO 51 The volumetric flow rate is measured with a measurement nozzle compliant with EN ISO 5167 For radial fans that are arranged in a plant in accordance with the directive, the total pressure difference p t p t = p td - p ts = ( p stat D + /2 * c D2 ) - ( p stat S + /2 * c S2 ) is used This figure corresponds to the total of all pressure losses from the fan that occur on the suction side (S) and on the pressure side (D) If the suctions and pressure joints are coextensive, the following applies: p t = p statd - p stats = p stat In practice, plant manufacturers often use a pressure difference that is reduced by the dynamic pressure Here, it is assumed that the dynamic pressure on the fan output cannot be used As for pressure fans, you can define the pressure difference for free outbound air flow p fa p fa = p t - /2 * c D 2 (The term static pressure difference is not correct for this variable) Duct sound power level L WA The measuring process for determining the channel sound power level is specified in DIN measurement of noise emitted by machines Evaluation takes place according to L WA =L measured value + * log ( /4*D 2 ) db D = diameter of the measuring line Sound pressure level L 3m Several measuring points are arranged on an enveloping surface around the fan The conversion to the specified 3 m level takes place according to L 3m =L measured value + 20 * log (r m /3m)dB 06

7 Series VRE direct-driven Technical explanation CASING POSITIONS (viewed from intake side) The position of the casing is specified at the plant and would require significant effort to change subsequently INSPECTION OPENING POSITION (viewed from intake side) For large fans and high pollution, maintenance work can be reduced by means of an additional inspection opening The position of the inspection opening in the intake side and/or drive side is always near the pressure side connection, whereas the position of the inspection opening in the casing jacket can be selected by specifying a degree in accordance with the casing position Possible positions of the cleaning hatch in the jacket of the casing 135 Position specified in degrees L 045L 0L 135L 1L 225L R 045R 0R 135R 1R 225R 07

8 Series VRE direct-driven Technical explanation TYPE OVERVIEW - PRESELECTION VRE 731 5, , , , ,0 U/min rpm 14 1,4 U/min rpm 9 U/min rpm U/min rpm Nenngröße Welded impeller with 8 backward curved vanes - Stable operation in the entire characteristic range - The fan can be operated outside of the specified characteristic range - Parallel connection is possible, series connection in consultation with the manufacture - Spiral casing - deep-drawn for models 2 - welded for special materials Bezugsdichte des Fördermediums = 12 1,2 kg/m³ 1, , , , , ,000, ,000, , , , ,1 0, ,3 04 0,4 0,5 05 1,0 20 2,0 30 3,0 40 4,0 50 5,0, ,0,0 0,0 VRE / 733 5, , , , ,0 U/min rpm 14 1,4 U/min rpm 9 U/min rpm U/min rpm Nenngröße Welded impeller with 12 backward curved vanes - Stable operation in the entire characteristic range - The fan can be operated outside of the specified characteristic range - Parallel connection is possible, series connection in consultation with the manufacture - Spiral casing - deep-drawn for models 2 - welded for special materials Bezugsdichte des Fördermediums = 1,2 12 kg/m³ 1, , , , , ,000, ,000, , , , ,1 0, ,3 04 0,4 0,5 05 1,0 2, ,0 40 4,0 50 5,0, ,0,0 0 V / m³/h 08

9 Series VRE direct-driven Technical explanation TYPE OVERVIEW - PRESELECTION VRE / 734 5, , , , ,0 U/min rpm 14 1,4 U/min rpm 9 9 U/min rpm U/min rpm Nenngröße Welded impeller with 35 forward curved vanes - Stable operation in the entire characteristic range - Operation outside of the characteristic range only in consultation with the manufacturer - Parallel connection is possible, series connection in consultation with the manufacturer - Spiral casing - deep-drawn for models 2 - welded for special materials Bezugsdichte des Fördermediums = 12 1,2 kg/m³ 1, , , , , ,000, ,000, ,02 0, , ,1 0, ,3 04 0,4 0,5 05 1,0 20 2,0 30 3,0 40 4,0 50 5,0, ,0,0 0 VRE / 673 5, , , , ,0 U/min rpm 14 1,4 U/min rpm 9 9 U/min rpm U/min rpm Nenngröße Welded impeller with 12 backward curved vanes - Stable operation in the entire characteristic range - The fan can be operated outside of the specified characteristic range - Parallel connection is possible, series connection in consultation with the manufacture - Spiral casing - deep-drawn for models 2 - welded for special materials Bezugsdichte des Fördermediums = 1,2 12 kg/m³ 1, , ,000 5, , ,000, ,000, ,02 0, , ,1 0,2 02 0,3 03 0,4 04 0,5 05 1,0 2, ,0 40 4,0 50 5,0, ,0,0 0 09

10 VRE Diagrams Impeller type 731 5, , , , ,6 U/min rpm 2,0 20 1, = 12 1,2 kg/m³ 002 0, , , ,2 03 0,3 04 0,4 0,5 05 1, , , , ,0 Impeller type 734 5, , , ,8 U/min rpm p / Pa t 0 1,000 2,0 20 1, , = 1,2 12kg/m³ 0, ,02 0, ,1 01 0, ,3 Impeller materials: 1, , , ,4 4 0, ,8 PPs, PPsX, PVC, PVDF GFRP GfK CFRP CfK

11 VRE Technical data MOTOR VARIANTS for standard motor 3~V/Hz (Data for other motor types eg single phase motors, pole changing motors or Ex motors on request) Fan type Speed rpm kw kw A kg db(a) db(a) D-total VRE /731W14 1, ) VRE /731W20 2, ) VRE /731W20 5,6 1) Level 2 4) VRE /734W14 1, ) VRE /734W20 2, Level 2 4) VRE /734W20 5,8 1) Level 2 4) 1) - during operation with frequency converter > Hz L A3m = A - evaluated noise level at a distance of 3 m 2) - Fan does not fall within scope of ErP directive L WA = A - evaluated noise level in the channel 3) - Fan for moving aggressive media 4) - When using IE2 motors 5) - When using IE3 motors 6) - When using IE4 motors Power requirement Nominal motor power Nominal motor current Weight with Motor L A3m L WA Octave level L WA-Okt / db(a) ErP category CASING POSITIONS The fan is available in casing positions L (left) and R (right), each in 6 different casing positions The position of the casing is set by the manufacturer and requires significant effort to change subsequently The axle height specified with casing position 0R in the dimension drawing remains unchanged 000L 045L 0L 135L 1L 225L Corresponding drawings in dxf format are available on the MIETZSCH CD 000R 045R 0R 135R 1R 225R 11

12 VRE Technical data MAIN DIMENSIONS for drive power <= 0,55 kw Casing position 0R Casing material: PPs, PVC Casing material: PE, PEX, PP, PPsX, PVDF Ø1 max Ø Ø1 max max max for drive power > 0,55 kw bis 2,2 kw Casing position 0R Casing material: PPs, PVC Casing material: PE, PEX, PP, PPsX, PVDF Ø1 5 max 3 Ø Ø1 3 max max max VIBRATION ISOLATION The manufacturer equips all fans with a set of rubber insulators of type -25SF that is designed for the size, speed and drive power of the fan Stainless steel spring insulators as eg type MFI20 can be exploited on special demand if natural frequency and isolation effectiveness require particulary high demands on vibration isolation Due to the materials used ( stainless steel A2 and PE-HD) stainless steel spring insulators can be used in areas sensitive to corrosion and hygiene Type -25 SF 72 M6 Ø27 4 Ø Type MFI 20 M6 M6 Ø36 Ø9 FRAME / FLANGE Frame and flange are designed according to MIETZSCH standard MWS 5 or MWS 5 Drilling pattern: 0 undrilled (eg F0, KOF0) 1 hole pattern 1 for normal requirements (eg KOF1) 2 hole pattern 2 (double the number of screws) for high positive pressures and strong condensation (eg F2, KOF2) Models according to other standards or special designs are possible on request Frame R Flange F Hole pattern 1 Hole pattern xØ Ø1 Ø1 Ø1 4xØ7 Ø1 Ø1 Ø1 4xØ7 12

13 ON ON VRE Accessories CASING CONNECTIONS The basic model of the fan depicted under MAIN DIMENSIONS can be supplemented with a range of accessories and thus adapted optimally to the specific operating conditions In addition to the standard range, special models and even special designs are possible on request The variants shown in the dimension drawing therefore only cover the most frequently used casing connections and condensate drains For detailed information, refer to the SPECIAL DESIGNS and ACCESSORIES sections Pressure side casing connection Casing material: PPs, PVC Ø Ø1 Casing material: PE, PEX, PP, PPsX, PVDF ABD 129 ABD 55 Ø1 Ø1 Ø1 F, welded R, welded ABS 135 KOR Ø1 Ø1 Ø1 SPS WS RS 5 Ø1 119 SPS Ø max17 Ø max17 1 Ø1 Ø1 5 RSF KOF Ø1 Ø1 KOF ELA + SPB Ø1 ELA + SPB Accessories WS RS Suction side casing connection Casing material: all USEG F KOF ELA + SPB Ø125Ø1 Ø1 Ø1 Ø1 Ø1 Ø1 Ø1 Condensate drain Casing material: all KSF KSV KSS 74 Ø5 Ø14 Ø75 Ø20 Ø20 Ø

14 VRE 1 Diagrams Impeller type 731 5, , , ,7 U/min rpm 5,4 54 3,8 38 p / Pa t 1, ,0 20 1, = 12 1,2 kg/m³ 1 1, , , , , ,1 01 0, ,3 0,4 04 0,5 05 1,0 20 2,0 Impeller type 734 5, , , ,9 U/min rpm 0 1,000 2,0 20 p / Pa t 1, = 1,2 12 kg/m³ 1 1, , , , ,02 0, ,1 02 0,2 03 0,3 04 0,4 05 0,5 Impeller materials: 1,0 V/m³/s PPs, PPsX, PVC, PVDF GFRP GfK CFRP CfK 14

15 VRE 1 Technical data MOTOR VARIANTS for standard motor 3~V/Hz (Data for other motor types eg single phase motors, pole changing motors or Ex motors on request) Fan type Speed rpm kw kw A kg db(a) db(a) D-total VRE 1/731W ) VRE 1/731W14 1, ) VRE 1/731W20 2, Level 2 4) VRE 1/731W20 5,7 1) Level 2 4) VRE 1/734W ) VRE 1/734W14 1, Level 2 4) VRE 1/734W20 2, Level 2 4) VRE 1/734W20 3,942 1) Level 2 4) VRE 1/673W ) VRE 1/673W14 1, ) VRE 1/673W20 2, Level 2 4) VRE 1/673W20 5,855 1) Level 2 4) 1) - during operation with frequency converter > Hz L A3m = A - evaluated noise level at a distance of 3 m 2) - Fan does not fall within scope of ErP directive L WA = A - evaluated noise level in the channel 3) - Fan for moving aggressive media 4) - When using IE2 motors 5) - When using IE3 motors 6) - When using IE4 motors Power requirement Nominal motor power Nominal motor current Weight with Motor L A3m L WA Octave level L WA-Okt / db(a) ErP category CASING POSITIONS The fan is available in casing positions L (left) and R (right), each in 6 different casing positions The position of the casing is set by the manufacturer and requires significant effort to change subsequently The axle height specified with casing position 0R in the dimension drawing remains unchanged 000L 045L 0L 135L 1L 225L Corresponding drawings in dxf format are available on the MIETZSCH CD 000R 045R 0R 135R 1R 225R 15

16 VRE 1 Technical data MAIN DIMENSIONS for drive power <= 3,0 kw Casing position 0R Casing material: PPs, PVC Casing material: PE, PEX, PP, PPsX, PVDF 141 max 5 Ø max max 5 Ø max Ø max17 Ø max17 Ø max17 Ø max for drive power > 3,0 kw bis 5,5 kw Casing position 0R Casing material: PPs, PVC Casing material: PE, PEX, PP, PPsX, PVDF VIBRATION ISOLATION The manufacturer equips all fans with a set of rubber insulators of type -25SF that is designed for the size, speed and drive power of the fan Stainless steel spring insulators as eg type MFI20 can be exploited on special demand if natural frequency and isolation effectiveness require particulary high demands on vibration isolation Due to the materials used ( stainless steel A2 and PE- HD) stainless steel spring insulators can be used in areas sensitive to corrosion and hygiene Type -25 SF 72 M6 4 Ø27 Ø Type MFI 20 M6 Ø36 M6 Ø9 FRAME / FLANGE Frame and flange are designed according to MIETZSCH standard MWS 5 or MWS 5 Drilling pattern: 0 undrilled (eg F0, KOF0) 1 hole pattern 1 for normal requirements (eg KOF1) 2 hole pattern 2 (double the number of screws) for high positive pressures and strong condensation (eg F2, KOF2) Models according to other standards or designs are possible on request special 16 Frame R Flange F Hole pattern 1 Hole pattern xØ Ø1 Ø2 8xØ7 Ø Ø1 Ø2 16xØ xØ7 Ø

17 ON ON VRE 1 Accessories CASING CONNECTIONS The basic model of the fan depicted under MAIN DIMENSIONS can be supplemented with a range of accessories and thus adapted optimally to the specific operating conditions In addition to the standard range, special models and even special designs are possible on request The variants shown in the dimension drawing therefore only cover the most frequently used casing connections and condensate drains For detailed information, refer to the SPECIAL DESIGNS and ACCESSORIES sections Pressure side casing connection Casing material: PPs, PVC Casing material: PE, PEX, PP, PPsX, PVDF Ø2 Ø Ø2 Ø1 Ø1 Ø2 Ø1 Ø1 83 ABD F, welded ABS KOF ELA + SPB Ø2 Ø1 Ø2 Ø1 Ø1 ABD R, welded KOR RSF KOF ELA + SPB Accessories SPS WS RS 141 Ø1 179 SPS WS RS Ø max17 Ø max Suction side casing connection Casing material: all USEG F KOF ELA + SPB Condensate drain Casing material: all KSF KSV KSS Ø Ø246 Ø1Ø2 Ø2 Ø1 Ø2 Ø1 Ø1 Ø25 Ø5 Ø75 Ø25 Ø22 17

18 VRE Diagrams Impeller type 731 Impeller type 733 5, , , U/min rpm 4,3 43 5, , ,5 U/min rpm 4,3 43 2, , ,0 20 2, ,1 31 2,0 20 1, ,000 0 p / Pa t 1,4 14 1, = 12 1,2 kg/m³ 1 1, , , , , ,1 02 0,2 03 0,3 04 0,4 0,5 05 1,0 2, ,0 4, = 12 1,2 kg/m³ 1, , , , , ,1 02 0,2 03 0,3 04 0,4 0,5 05 1,0 2, ,0 40 4,0 Impeller type 734 Impeller type 673 5, , ,3 U/min rpm 4,7 47 3, , ,2 U/min rpm 2,0 20 3, , , 3 2, , ,000 p / Pa t p / Pa t 1,4 14 1, = 1,2 12kg/m³ 1, , , , , ,1 02 0,2 03 0,3 04 0,4 05 0,5 1,0 20 2,0 Impeller materials: = 12 1,2 kg/m³ 1, , , , , ,1 02 0,2 03 0,3 04 0,4 0,5 05 1,0 PPs, PPsX, PVC, PVDF GFRP GfK CFRP CfK 20 2,0

19 VRE Technical data MOTOR VARIANTS for standard motor 3~V/Hz (Data for other motor types eg single phase motors, pole changing motors or Ex motors on request) Fan type Speed rpm kw kw A kg db(a) db(a) D-total VRE /731W ) VRE /731W ) VRE /731W14 1, Level 2 4) VRE /731W20 2, Level 2 4) VRE /731W20 5, 1) Level 2 4) VRE /733W ) VRE /733W ) VRE /733W14 1, Level 2 4) VRE /733W20 2, Level 2 4) VRE /733W20 5,5 1) Level 2 5) VRE /734W ) VRE /734W ) VRE /734W14 1, Level 2 4) VRE /734W20 2, Level 2 5) VRE /734W20 3,2 1) Level 2 5) VRE /673W ) VRE /673W14 1, Level 2 4) VRE /673W20 2, Level 2 4) VRE /673W20 5,3 1) Level 2 5) 1) - during operation with frequency converter > Hz L A3m = A - evaluated noise level at a distance of 3 m 2) - Fan does not fall within scope of ErP directive L WA = A - evaluated noise level in the channel 3) - Fan for moving aggressive media 4) - When using IE2 motors 5) - When using IE3 motors 6) - When using IE4 motors Power requirement Nominal motor power Nominal motor current Weight with Motor L A3m L WA Octave level L WA-Okt / db(a) ErP category CASING POSITIONS The fan is available in casing positions L (left) and R (right), each in 6 different casing positions The position of the casing is set by the manufacturer and requires significant effort to change subsequently The axle height specified with casing position 0R in the dimension drawing remains unchanged 000L 045L 0L 135L 1L 225L Corresponding drawings in dxf format are available on the MIETZSCH CD 000R 045R 0R 135R 1R 225R 19

20 VRE Technical data MAIN DIMENSIONS for drive power <= 4,0 kw Casing position 0R Casing material: PPs, PVC Casing material: PE, PEX, PP, PPsX, PVDF 169 max 616 Ø max max max17 Ø 635 Ø 632 Ø 395 max Ø max for drive power > 4,0 kw bis 11 kw Casing position 0R Casing material: PPs, PVC Casing material: PE, PEX, PP, PPsX, PVDF max max Ø VIBRATION ISOLATION The manufacturer equips all fans with a set of rubber insulators of type -25SF that is designed for the size, speed and drive power of the fan Stainless steel spring insulators as eg type MFI20 can be exploited on special demand if natural frequency and isolation effectiveness require particulary high demands on vibration isolation Due to the materials used ( stainless steel A2 and PE- HD) stainless steel spring insulators can be used in areas sensitive to corrosion and hygiene FRAME / FLANGE Frame and flange are designed according to MIETZSCH standard MWS 5 or MWS 5 Drilling pattern: 0 undrilled (eg F0, KOF0) 1 hole pattern 1 for normal requirements (eg KOF1) 2 hole pattern 2 (double the number of screws) for high positive pressures and strong condensation (eg F2, KOF2) Models according to other standards or designs are possible on request special 20 Frame R Flange F Type -25 SF 72 M6 4 Ø27 Ø Hole pattern 1 Hole pattern xØ Ø Ø xØ Ø2 Ø2 16xØ7 8xØ7 Type MFI 20 M6 M6 Ø36 Ø9 Ø Ø2

21 ON ON VRE Accessories CASING CONNECTIONS The basic model of the fan depicted under MAIN DIMENSIONS can be supplemented with a range of accessories and thus adapted optimally to the specific operating conditions In addition to the standard range, special models and even special designs are possible on request The variants shown in the dimension drawing therefore only cover the most frequently used casing connections and condensate drains For detailed information, refer to the SPECIAL DESIGNS and ACCESSORIES sections Pressure side casing connection Casing material: PPs, PVC Ø3 Ø2 Casing material: PE, PEX, PP, PPsX, PVDF ABD 219 ABD 55 Ø2 Ø F, welded R, welded Ø ABS KOR 85 Ø2 Ø RSF 135 Ø2 Ø KOF Ø2 Ø KOF Ø ELA + SPB 1 Ø Ø 224 Ø SPS 1 WS RS max ELA + SPB Ø max Accessories SPS WS RS Suction side casing connection Casing material: all USEG F KOF ELA + SPB Ø3 Ø2 Ø315 Ø2 Ø Ø2 Ø Ø Condensate drain Casing material: all KSF KSV KSS 73 Ø5 Ø25 Ø14 Ø Ø25 Ø22 21

22 VRE 2 Diagrams Impeller type 731 Impeller type 733 5, ,2 U/min rpm 3, , ,4 34 2,0 20 2, 2 5, , , ,2 U/min rpm 3,4 34 2,0 20 2, ,000 1, ,4 14 1, = 1,2 12 kg/m³ 1, , , , , ,1 02 0,2 03 0,3 04 0,4 0,5 05 1,0 20 2,0 3,0 4, , = 12 1,2 kg/m³ 1, , , , , ,0 01 0,1 02 0,2 03 0,3 04 0,4 0,5 05 1,0 20 2,0 3, ,0 50 Impeller type 734 Impeller type ,685 U/min rpm 5, , ,8 3, , ,4 U/min rpm 0 3, ,000 2,0 20 2, ,000 1, ,000 1, = 1,2 12 kg/m³ 1, , , , , ,1 02 0,2 03 0,3 04 0,4 0,5 05 1,0 20 2,0 3, ,0 5,0 50 Impeller materials: = 1,2 12 kg/m³ 1, , , , , ,1 02 0,2 03 0,3 04 0,4 0,5 05 1,0 2,0 20 3, ,0 5,0 50 PPs, PPsX, PVC, PVDF GFRP GfK CFRP CfK

23 VRE 2 Technical data MOTOR VARIANTS for standard motor 3~V/Hz (Data for other motor types eg single phase motors, pole changing motors or Ex motors on request) Fan type Speed rpm kw kw A kg db(a) db(a) D-total VRE2/731W ) VRE2/731W ) VRE2/731W14 1, Level 2 4) VRE2/731W20 2, Level 2 4) VRE2/731W20 4,2 1) Level 2 5) VRE2/733W ) VRE2/733W ) VRE2/733W14 1, Level 2 4) VRE2/733W20 2, Level 2 5) VRE2/733W20 4,2 1) Level 2 5) VRE2/734W ) VRE2/734W Level 2 4) VRE2/734W14 1, Level 2 4) VRE2/734W14 2,4 1) Level 2 5) VRE2/673W ) VRE2/673W ) VRE2/673W14 1, Level 2 VRE2/673W20 2, Level 2 4) VRE2/673W20 4,685 1) Level 2 5) 1) - during operation with frequency converter > Hz L A3m = A - evaluated noise level at a distance of 3 m 2) - Fan does not fall within scope of ErP directive L WA = A - evaluated noise level in the channel 3) - Fan for moving aggressive media 4) - When using IE2 motors 5) - When using IE3 motors 6) - When using IE4 motors Power requirement Nominal motor power Nominal motor current Weight with Motor L A3m L WA Octave level L WA-Okt / db(a) ErP category CASING POSITIONS The fan is available in casing positions L (left) and R (right), each in 6 different casing positions The position of the casing is set by the manufacturer and requires significant effort to change subsequently The axle height specified with casing position 0R in the dimension drawing remains unchanged 000L 045L 0L 135L 1L 225L Corresponding drawings in dxf format are available on the MIETZSCH CD 000R 045R 0R 135R 1R 225R 23

24 VRE 2 Technical data MAIN DIMENSIONS for drive power <= 5,5 kw Casing position 0R Casing material: PPs, PVC Casing material: PE, PEX, PP, PPsX, PVDF max 782 max Ø Casing material: PPs, PVC Casing material: PE, PEX, PP, PPsX, PVDF max 888 max Ø max21 4 max21 Ø2 7 Ø2 7 4 max21 4 max21 Ø2 7 Ø for drive power > 5,5 kw bis 15 kw Casing position 0R VIBRATION ISOLATION The manufacturer equips all fans with a set of rubber insulators of type -SF that is designed for the size, speed and drive power of the fan Stainless steel spring insulators as eg type MFI20 / MFI can be exploited on special demand if natural frequency and isolation effectiveness require particulary high demands on vibration isolation Due to the materials used ( stainless steel A2 and PE- HD) stainless steel spring insulators can be used in areas sensitive to corrosion and hygiene Type - SF Ø Ø7 M Type MFI 20 M6 / MFI M8 Ø36 Ø9 M6/M8 FRAME / FLANGE Frame and flange are designed according to MIETZSCH standard MWS 5 or MWS 5 Drilling pattern: 0 undrilled (eg F0, KOF0) 1 hole pattern 1 for normal requirements (eg KOF1) 2 hole pattern 2 (double the number of screws) for high positive pressures and strong condensation (eg F2, KOF2) Models according to other standards or designs are possible on request special 24 Frame R Flange F Hole pattern 1 Hole pattern Ø xø Ø320 Ø2 12xØ Ø2 Ø xØ Ø2 24xØ7 266

25 ON ON VRE 2 Accessories CASING CONNECTIONS The basic model of the fan depicted under MAIN DIMENSIONS can be supplemented with a range of accessories and thus adapted optimally to the specific operating conditions In addition to the standard range, special models and even special designs are possible on request The variants shown in the dimension drawing therefore only cover the most frequently used casing connections and condensate drains For detailed information, refer to the SPECIAL DESIGNS and ACCESSORIES sections Pressure side casing connection Casing material: PPs, PVC Ø395 Ø315 Casing material: PE, PEX, PP, PPsX, PVDF Ø320 Ø2 Ø2 6 ABD F, welded ABS Ø320 Ø2 ABD R, welded KOR RSF Ø320 Ø2 KOF 205 Ø320 Ø2 KOF 2 Ø2 4 max21 Ø1 125 Ø2 7 Ø Ø2 ELA + SPB 325 Ø2 ELA + SPB Accessories SPS WS RS 203 SPS WS ROE 236 RS max Ø Suction side casing connection Casing material: all USEG F KOF ELA + SPB Condensate drain Casing material: all KSF KSV KSS 66 Ø Ø2 Ø Ø320 Ø2 Ø320 Ø2 Ø2 Ø117 Ø32 78 Ø14 Ø85 Ø Ø22 25

26 VRE 315 Diagrams Impeller type 731 Impeller type 733 5, , ,3 U/min rpm 2,0 20 2, , , , ,225 U/min rpm 2,0 20 2, , , ,000 1,9 19 1, , ,000 1, = 12 1,2 kg/m³ 1, , , , ,000 00, ,1 02 0,2 03 0,3 04 0,4 0,5 05 1,0 2, ,0 4,0 0 5,0 50 8, = 12 1,2 kg/m³ 1, , , , ,000 00, ,0 5,0 01 0,1 02 0,2 03 0,3 04 0,4 0,5 05 1,0 20 2,0 3, ,0 80 Impeller type 734 Impeller type 673 5, , , ,9 U/min rpm 5, , , ,575 U/min rpm 3,0 2,0 20 2, ,000 1, ,000 1, = 1,2 12 kg/m³ 1, , , , , , ,1 02 0,2 03 0,3 04 0,4 0,5 05 1,0 2,0 20 3,0 30 4,0 0 5,0 50 8,0 80 Impeller materials: = 12 1,2 kg/m³ 01 0,1 02 0,2 03 0,3 04 0,4 05 0,5 1,0 2,0 20 PPs, PPsX, PVC, PVDF GFRP GfK CFRP CfK 1, , , , , ,0 4, ,0 50

27 VRE 315 Technical data MOTOR VARIANTS for standard motor 3~V/Hz (Data for other motor types eg single phase motors, pole changing motors or Ex motors on request) Fan type Speed rpm kw kw A kg db(a) db(a) D-total VRE2/731W ) VRE2/731W ) VRE2/731W14 1, Level 2 4) VRE2/731W20 2, Level 2 4) VRE2/731W20 4,2 1) Level 2 5) VRE2/733W ) VRE2/733W ) VRE2/733W14 1, Level 2 4) VRE2/733W20 2, Level 2 5) VRE2/733W20 4,2 1) Level 2 5) VRE2/734W ) VRE2/734W Level 2 4) VRE2/734W14 1, Level 2 4) VRE2/734W14 2,4 1) Level 2 5) VRE2/673W ) VRE2/673W ) VRE2/673W14 1, Level 2 VRE2/673W20 2, Level 2 4) VRE2/673W20 4,685 1) Level 2 5) 1) - during operation with frequency converter > Hz L A3m = A - evaluated noise level at a distance of 3 m 2) - Fan does not fall within scope of ErP directive L WA = A - evaluated noise level in the channel 3) - Fan for moving aggressive media 4) - When using IE2 motors 5) - When using IE3 motors 6) - When using IE4 motors Power requirement Nominal motor power Nominal motor current Weight with Motor L A3m L WA Octave level L WA-Okt / db(a) ErP category CASING POSITIONS The fan is available in casing positions L (left) and R (right), each in 6 different casing positions The position of the casing is set by the manufacturer and requires significant effort to change subsequently The axle height specified with casing position 0R in the dimension drawing remains unchanged 000L 045L 0L 135L 1L 225L Corresponding drawings in dxf format are available on the MIETZSCH CD 000R 045R 0R 135R 1R 225R 27

28 VRE 315 Technical data MAIN DIMENSIONS Casing position 0R Casing material: PPs, PVC, PE, PEX, PP, PPsX, PVDF for drive power: <= 15 kw > 15 kw bis 22 kw max max Ø max Ø max VIBRATION ISOLATION The manufacturer equips all fans with a set of rubber insulators of type -SF that is designed for the size, speed and drive power of the fan Stainless steel spring insulators as eg type MFI can be exploited on special demand if natural frequency and isolation effectiveness require particulary high demands on vibration isolation Due to the materials used ( stainless steel A2 and PE- HD) stainless steel spring insulators can be used in areas sensitive to corrosion and hygiene Type - SF Ø Ø7 M Type MFI M8 Ø36 Ø9 M8 FRAME / FLANGE Frame and flange are designed according to MIETZSCH standard MWS 5 or MWS 5 Drilling pattern: 0 undrilled (eg F0, KOF0) 1 hole pattern 1 for normal requirements (eg KOF1) 2 hole pattern 2 (double the number of screws) for high positive pressures and strong condensation (eg F2, KOF2) Models according to other standards or special designs are possible on request Frame R 3 22 Flange F Hole pattern 1 Hole pattern Ø xØ Ø Ø xØ Ø Ø3 Ø3 24xØ 12xØ 28

29 ON VRE 315 Accessories CASING CONNECTIONS The basic model of the fan depicted under MAIN DIMENSIONS can be supplemented with a range of accessories and thus adapted optimally to the specific operating conditions In addition to the standard range, special models and even special designs are possible on request The variants shown in the dimension drawing therefore only cover the most frequently used casing connections and condensate drains For detailed information, refer to the SPECIAL DESIGNS and ACCESSORIES sections Pressure side casing connection Casing material: PPs, PVC, PE, PEX, PP, PPsX, PVDF ABD R, welded KOR 256 Ø395 Ø315 RSF Ø395 Ø315 KOF 385 Ø315 ELA + SPB Suction side casing connection 375 Casing material: all USEG F KOF ELA + SPB Accessories SPS WS RS Ø492 Ø Ø Ø395 Ø315 Ø395 Ø315 Ø315 Ø315 Ø1 Ø1 ROE Condensate drain Casing material: all KSF KSV KSS Ø max21 Ø85 Ø117 Ø32 78 Ø32 85 Ø

30 VRE Diagrams Impeller type 731 Impeller type , , ,645 U/min rpm 2, , , , ,575 U/min rpm 2, ,000 1, , ,000 1,5 15 1, , , = 12 1,2 kg/m³ 1, , , , ,000 00,000 00, ,15 0, ,3 0,4 04 0,5 05 1,0 2, ,0 4,0 40 5,0 50 0,0 3 = 12 1,2 kg/m³ 1, , , , ,000 00,000 00, , ,2 03 0,3 04 0,4 0,5 05 1,0 20 2,0 30 3,0 40 4,0 5,0 50 0,0 Impeller type 734 Impeller type 673 5, , , ,8 U/min rpm 2, , , ,555 U/min rpm 1, , ,000 1, , , , = 12 1,2 kg/m³ 1, , , , ,000 00,000 00, , ,2 03 0,3 04 0,4 0,5 05 1,0 20 2,0 30 3,0 40 4,0 5,0 50,0 Impeller materials: 4 = 12 1,2 kg/m³ 1, , ,000 5, ,00000, ,1 02 0,2 03 0,3 04 0,4 0,5 05 1,0 2,0 20 3,0 30 4,0 0 5,0 50 8,0 80 PPs, PPsX, PVC, PVDF GFRP GfK CFRP CfK

31 VRE Technical data MOTOR VARIANTS for standard motor 3~V/Hz (Data for other motor types eg single phase motors, pole changing motors or Ex motors on request) Fan type Speed rpm kw kw A kg db(a) db(a) D-total VRE /731W ) VRE /731W Level 2 4) VRE /731W14 1, Level 2 4) VRE /731W14 2,645 1) Level 2 5) VRE /733W ) VRE /733W Level 2 4) VRE /733W14 1, Level 2 5) VRE /733W14 2,645 1) Level 2 5) VRE /734W Level 2 VRE /734W Level 2 5) VRE /734W14 1, Level 2 5) VRE /734W14 1,555 1) Level 2 5) VRE /673W ) VRE /673W Level 2 4) VRE /673W14 1, Level 2 4) VRE /673W14 2,8 1) Level 2 5) 1) - during operation with frequency converter > Hz L A3m = A - evaluated noise level at a distance of 3 m 2) - Fan does not fall within scope of ErP directive L WA = A - evaluated noise level in the channel 3) - Fan for moving aggressive media 4) - When using IE2 motors 5) - When using IE3 motors 6) - When using IE4 motors Power requirement Nominal motor power Nominal motor current Weight with Motor L A3m L WA Octave level L WA-Okt / db(a) ErP category CASING POSITIONS The fan is available in casing positions L (left) and R (right), each in 6 different casing positions The position of the casing is set by the manufacturer and requires significant effort to change subsequently The axle height specified with casing position 0R in the dimension drawing remains unchanged 000L 045L 0L 135L 1L 225L Corresponding drawings in dxf format are available on the MIETZSCH CD 000R 045R 0R 135R 1R 225R 31

32 VRE Technical data MAIN DIMENSIONS Casing position 0R Casing material: PPs, PVC, PE, PEX, PP, PPsX, PVDF for drive power: <= 15 kw > 15 kw bis 37 kw 284 max max max Ø max24 7 Ø VIBRATION ISOLATION The manufacturer equips all fans with a set of rubber insulators of type -SF that is designed for the size, speed and drive power of the fan Stainless steel spring insulators as eg type MFI- M8 can be exploited on special demand if natural frequency and isolation effectiveness require particulary high demands on vibration isolation Due to the materials used ( stainless steel A2 and PE- HD) stainless steel spring insulators can be used in areas sensitive to corrosion and hygiene Type - SF M8 Ø42 Ø9 M Type MFI M8 Ø36 Ø9 M8 FRAME / FLANGE Frame and flange are designed according to MIETZSCH standard MWS 5 or MWS 5 Drilling pattern: 0 undrilled (eg F0, KOF0) 1 hole pattern 1 for normal requirements (eg KOF1) 2 hole pattern 2 (double the number of screws) for high positive pressures and strong condensation (eg F2, KOF2) Models according to other standards or special designs are possible on request Frame R Flange F Hole pattern 1 Hole pattern Ø Ø4 16xØ Ø444 12xØ Ø 22 24xØ Ø Ø444 24xØ

33 ON VRE Accessories CASING CONNECTIONS The basic model of the fan depicted under MAIN DIMENSIONS can be supplemented with a range of accessories and thus adapted optimally to the specific operating conditions In addition to the standard range, special models and even special designs are possible on request The variants shown in the dimension drawing therefore only cover the most frequently used casing connections and condensate drains For detailed information, refer to the SPECIAL DESIGNS and ACCESSORIES sections Pressure side casing connection Casing material: PPs, PVC, PE, PEX, PP, PPsX, PVDF ABD 4 R, welded KOR Ø4 Ø Ø4 Ø RSF KOF Ø ELA + SPB Suction side casing connection Casing material: all USEG F KOF ELA + SPB Accessories SPS WS 3 3 RS 446 Ø620 Ø Ø6 Ø4 Ø Ø4 Ø Ø Condensate drain Casing material: all KSF KSV KSS Ø14 Ø 8 2x Ø1 ROE max Ø85 Ø117 Ø32 78 Ø32 85 Ø

34 VRE 4 Diagrams Impeller type 731 Impeller type 733 5, , ,3 U/min rpm 1, , , , ,2 U/min rpm 1, ,000 1,4 14 1, ,000 1,4 14 1, , , = 12 1,2 kg/m³ 0 1,000 2, ,000 5, ,000 00,000 00,000 00, ,3 04 0,4 0,5 05 1,0 20 2,0 30 3,0 4,0 40 5,0 50, ,0 3 = 12 1,2 kg/m³ 0 1, , ,000 5, , ,000,000 00, ,3 04 0,4 05 0,5 1,0 20 2,0 30 3,0 40 4,0 50 5,0, ,0 Impeller type 734 Impeller type 673 5, , , ,345 U/min rpm 2, , , ,385 U/min rpm 0 3, ,000 1,5 15 1, , , = 12 1,2 kg/m³ 1, , , , ,000 00,000 00, , ,2 03 0,3 04 0,4 0,5 05 1,0 20 2,0 30 3,0 40 4,0 5,0 50,0 0 Impeller materials: = 12 1,2 kg/m³ 1, , , , ,000 00,000 00, , ,2 03 0,3 04 0,4 0,5 05 1,0 2, ,0 4,0 40 5,0 50,0 0 PPs, PPsX, PVC, PVDF GFRP GfK CFRP CfK

35 VRE 4 Technical data MOTOR VARIANTS for standard motor 3~V/Hz (Data for other motor types eg single phase motors, pole changing motors or Ex motors on request) Fan type Speed rpm kw kw A kg db(a) db(a) D-total VRE 4/731W ) VRE 4/731W Level 2 4) VRE 4/731W14 1, Level 2 5) VRE 4/731W14 2,3 1) Level 2 5) VRE 4/733W ) VRE 4/733W Level 2 4) VRE 4/733W14 1, Level 2 5) VRE 4/733W14 2,2 1) Level 2 5) VRE 4/734W Level 2 VRE 4/734W Level 2 5) VRE 4/734W9 1,385 1) Level 2 5) VRE 4/673W Level 2 VRE 4/673W Level 2 4) VRE 4/673W14 1, Level 2 5) VRE 4/673W14 2,346 1) Level 2 5) 1) - during operation with frequency converter > Hz L A3m = A - evaluated noise level at a distance of 3 m 2) - Fan does not fall within scope of ErP directive L WA = A - evaluated noise level in the channel 3) - Fan for moving aggressive media 4) - When using IE2 motors 5) - When using IE3 motors 6) - When using IE4 motors Power requirement Nominal motor power Nominal motor current Weight with Motor L A3m L WA Octave level L WA-Okt / db(a) ErP category CASING POSITIONS The fan is available in casing positions L (left) and R (right), each in 6 different casing positions The position of the casing is set by the manufacturer and requires significant effort to change subsequently The axle height specified with casing position 0R in the dimension drawing remains unchanged 000L 045L 0L 135L 1L 225L Corresponding drawings in dxf format are available on the MIETZSCH CD 000R 045R 0R 135R 1R 225R 35

36 VRE 4 Technical data MAIN DIMENSIONS Casing position 0R Casing material: PPs, PVC, PE, PEX, PP, PPsX, PVDF for drive power: <= 15 kw > 15 kw bis 37 kw max max Ø max Ø max VIBRATION ISOLATION The manufacturer equips all fans with a set of rubber insulators of type -SF that is designed for the size, speed and drive power of the fan Stainless steel spring insulators as eg type MFI- M8 can be exploited on special demand if natural frequency and isolation effectiveness require particulary high demands on vibration isolation Due to the materials used ( stainless steel A2 and PE- HD) stainless steel spring insulators can be used in areas sensitive to corrosion and hygiene Type - SF M Ø42 Ø9 M Type MFI M8 Ø36 Ø9 M8 FRAME / FLANGE Frame and flange are designed according to MIETZSCH standard MWS 5 or MWS 5 Drilling pattern: 0 undrilled (eg F0, KOF0) 1 hole pattern 1 for normal requirements (eg KOF1) 2 hole pattern 2 (double the number of screws) for high positive pressures and strong condensation (eg F2, KOF2) Models according to other standards or special designs are possible on request Frame R Flange F Hole pattern 1 Hole pattern Ø xØ Ø5 Ø Ø4 24xØ Ø5 Ø xØ 24xØ 36

37 ON VRE 4 Accessories CASING CONNECTIONS The basic model of the fan depicted under MAIN DIMENSIONS can be supplemented with a range of accessories and thus adapted optimally to the specific operating conditions In addition to the standard range, special models and even special designs are possible on request The variants shown in the dimension drawing therefore only cover the most frequently used casing connections and condensate drains For detailed information, refer to the SPECIAL DESIGNS and ACCESSORIES sections Pressure side casing connection Casing material: PPs, PVC, PE, PEX, PP, PPsX, PVDF ABD R, welded KOR Ø5 Ø RSF Ø5 Ø4 KOF Ø4 ELA + SPB Suction side casing connection Casing material: all USEG F KOF ELA + SPB Accessories SPS WS RS 2x Ø0 Ø5 Ø Ø5 Ø4 Ø5 Ø4 Ø4 Condensate drain Casing material: all KSF KSV KSS Ø14 Ø4 884 Ø1 ROE max Ø85 Ø117 Ø32 78 Ø32 85 Ø

38 VRE Diagrams Impeller type 731 Impeller type 733 5, , , ,115 U/min rpm 1,7 17 1,4 14 1, , , , ,000 2,2 rpm 1895 U/min 1, ,4 1, , , = 12 1,2 kg/m³ 1, , ,000 5, ,000 00,000 00,000 00, ,3 04 0,4 05 0,5 1,0 20 2,0 30 3,0 4,0 40 5,0 50, ,0 2 = 1,2 12 kg/m³ 0 1, , ,000 5, ,000 00,000 00,000 00, , ,4 0,5 05 1,0 20 2,0 30 3,0 4, ,0, ,0 Impeller type 734 Impeller type , ,000 5, ,0 U/min rpm 1, , , ,245 U/min rpm 0 3, ,000 1,4 14 1, , , = 12 1,2 kg/m³ 1, , , , ,000 00,000 00, ,15 0, ,3 0,4 04 0,5 05 1,0 2, ,0 40 4,0 5,0 50,0 Impeller materials: 38 = 12 1,2 kg/m³ 1, , , , ,000 00,000 00, , ,2 03 0,3 04 0,4 0,5 05 1,0 2, ,0 40 4,0 5,0 50,0 PPs, PPsX, PVC, PVDF GFRP GfK CFRP CfK

39 VRE Technical data MOTOR VARIANTS for standard motor 3~V/Hz (Data for other motor types eg single phase motors, pole changing motors or Ex motors on request) Fan type Speed rpm kw kw A kg db(a) db(a) D-total VRE /731W ) VRE /731W Level 2 4) VRE /731W14 1, Level 2 5) VRE /731W14 2,115 1) Level 2 5) VRE /733W ) VRE /733W Level 2 5) VRE /733W14 1, Level 2 5) VRE /733W14 1,895 1) Level 2 5) VRE /734W Level 2 VRE /734W9 9 21, Level 2 5) VRE /734W9 1,245 1) Level 2 5) VRE /673W Level 2 VRE /673W Level 2 4) VRE /673W14 1, Level 2 5) VRE /673W14 2,0 1) Level 2 5) 1) - during operation with frequency converter > Hz L A3m = A - evaluated noise level at a distance of 3 m 2) - Fan does not fall within scope of ErP directive L WA = A - evaluated noise level in the channel 3) - Fan for moving aggressive media 4) - When using IE2 motors 5) - When using IE3 motors 6) - When using IE4 motors Power requirement Nominal motor power Nominal motor current Weight with Motor L A3m L WA Octave level L WA-Okt / db(a) ErP category CASING POSITIONS The fan is available in casing positions L (left) and R (right), each in 6 different casing positions The position of the casing is set by the manufacturer and requires significant effort to change subsequently The axle height specified with casing position 0R in the dimension drawing remains unchanged 000L 045L 0L 135L 1L 225L Corresponding drawings in dxf format are available on the MIETZSCH CD 000R 045R 0R 135R 1R 225R 39

40 VRE Technical data MAIN DIMENSIONS Casing position 0R Casing material: PPs, PVC, PE, PEX, PP, PPsX, PVDF for drive power: <= 15 kw > 15 kw bis 45 kw 1431 max max Ø max Ø max VIBRATION ISOLATION The manufacturer equips all fans with a set of rubber insulators of type -SF that is designed for the size, speed and drive power of the fan Stainless steel spring insulators as eg type MFI- M8 can be exploited on special demand if natural frequency and isolation effectiveness require particulary high demands on vibration isolation Due to the materials used ( stainless steel A2 and PE- HD) stainless steel spring insulators can be used in areas sensitive to corrosion and hygiene Type - SF M Ø42 Ø9 M Typ MFI M8 Ø36 Ø9 M8 FRAME / FLANGE Frame and flange are designed according to MIETZSCH standard MWS 5 or MWS 5 Drilling pattern: 0 undrilled (eg F0, KOF0) 1 hole pattern 1 for normal requirements (eg KOF1) 2 hole pattern 2 (double the number of screws) for high positive pressures and strong condensation (eg F2, KOF2) Models according to other standards or special designs are possible on request Frame R Hole pattern 1 Hole pattern xØ Ø xØ Ø5 8 Flange F Ø Ø Ø544 12xØ Ø544 24xØ

41 ON VRE Accessories CASING CONNECTIONS The basic model of the fan depicted under MAIN DIMENSIONS can be supplemented with a range of accessories and thus adapted optimally to the specific operating conditions In addition to the standard range, special models and even special designs are possible on request The variants shown in the dimension drawing therefore only cover the most frequently used casing connections and condensate drains For detailed information, refer to the SPECIAL DESIGNS and ACCESSORIES sections Pressure side casing connection Casing material: PPs, PVC, PE, PEX, PP, PPsX, PVDF ABD R, welded KOR Ø5 Ø RSF 6 Ø5 Ø KOF Ø ELA + SPB Suction side casing connection Casing material: all USEG F KOF ELA + SPB Accessories SPS WS RS x Ø7 Ø6 Ø0 Ø5 Ø Ø5 Ø Ø Ø Ø ROE 920 Condensate drain Casing material: all KSF KSV KSS Ø max24 Ø Ø1 88 Ø Ø 95 Ø

42 VRE 5 Diagrams Impeller type 731 Impeller type , , , ,8 U/min rpm 1, , , , ,000 18U/min 1,8 rpm 1,5 15 1, ,000 1, ,000 1, , ,000 5 = 12 1,2 kg/m³ 0 1,000 2, ,000 5, , ,000,000 00, ,3 04 0,4 0,5 05 1,0 20 2,0 3,0 30 4,0 40 5,0 50,0 0 20,0 0 2 = 12 1,2 kg/m³ 0 1, , ,000 5, , ,000,000 00, ,3 04 0,4 0,5 05 1,0 20 2,0 30 3,0 4, ,0,0 0 20,0 0 Impeller type 734 Impeller type ,045 U/min rpm 5, , , ,1 U/min rpm 9 0 5, , , ,000 1, ,4 14 1, , , = 12 1,2 kg/m³ 1, , , , ,000 00,000 00,000 00, ,3 04 0,4 0,5 05 1,0 20 2,0 30 3,0 40 4,0 5,0 50, ,0 Impeller materials: 42 = 12 1,2 kg/m³ 1, , , , ,000 00,000 00,000 00, ,3 04 0,4 0,5 05 1,0 20 2,0 3,0 30 4,0 40 5,0 50,0 0 PPs, PPsX, PVC, PVDF GFRP GfK CFRP CfK 20,0 0

43 VRE 5 Technical data MOTOR VARIANTS for standard motor 3~V/Hz (Data for other motor types eg single phase motors, pole changing motors or Ex motors on request) Fan type Speed rpm kw kw A kg db(a) db(a) D-total VRE 5/731W ) VRE 5/731W Level 2 5) VRE 5/731W14 1, Level 2 5) VRE 5/731W14 1,8 1) Level 2 5) VRE 5/733W ) VRE 5/733W Level 2 5) VRE 5/733W14 1, Level 2 5) VRE 5/733W14 1,8 1) Level 2 5) VRE 5/734W Level 2 VRE 5/734W Level 2 5) VRE 5/734W9 1,1 1) Level 2 5) VRE 5/673W Level 2 VRE 5/673W Level 2 5) VRE 5/673W14 1, Level 2 5) VRE 5/673W14 2,045 1) Level 2 5) 1) - during operation with frequency converter > Hz L A3m = A - evaluated noise level at a distance of 3 m 2) - Fan does not fall within scope of ErP directive L WA = A - evaluated noise level in the channel 3) - Fan for moving aggressive media 4) - When using IE2 motors 5) - When using IE3 motors 6) - When using IE4 motors Power requirement Nominal motor power Nominal motor current Weight with Motor L A3m L WA Octave level L WA-Okt / db(a) ErP category CASING POSITIONS The fan is available in casing positions L (left) and R (right), each in 6 different casing positions The position of the casing is set by the manufacturer and requires significant effort to change subsequently The axle height specified with casing position 0R in the dimension drawing remains unchanged 000L 045L 0L 135L 1L 225L Corresponding drawings in dxf format are available on the MIETZSCH CD 000R 045R 0R 135R 1R 225R 43

44 VRE 5 Technical data MAIN DIMENSIONS Casing position 0R Casing material: PPs, PVC, PE, PEX, PP, PPsX, PVDF for drive power: <= 15 kw > 15 kw bis 75 kw max max Ø max 5 max Ø VIBRATION ISOLATION The manufacturer equips all fans with a set of rubber insulators of type -SF that is designed for the size, speed and drive power of the fan Stainless steel spring insulators as eg type MFI120- M8 can be exploited on special demand if natural frequency and isolation effectiveness require particulary high demands on vibration isolation Due to the materials used ( stainless steel A2 and PE- HD) stainless steel spring insulators can be used in areas sensitive to corrosion and hygiene Type - SF M Ø95 M Ø53 Type MFI 120 M8 Ø M8 Ø FRAME / FLANGE Frame and flange are designed according to MIETZSCH standard MWS 5 or MWS 5 Drilling pattern: 0 undrilled (eg F0, KOF0) 1 hole pattern 1 for normal requirements (eg KOF1) 2 hole pattern 2 (double the number of screws) for high positive pressures and strong condensation (eg F2, KOF2) Models according to other standards or special designs are possible on request Frame R Flansch F Hole pattern 1 Hole pattern Ø xØ 61 2 Ø6 Ø4 16xØ Ø xØ Ø6 Ø4 32xØ

45 ON VRE 5 Accessories CASING CONNECTIONS The basic model of the fan depicted under MAIN DIMENSIONS can be supplemented with a range of accessories and thus adapted optimally to the specific operating conditions In addition to the standard range, special models and even special designs are possible on request The variants shown in the dimension drawing therefore only cover the most frequently used casing connections and condensate drains For detailed information, refer to the SPECIAL DESIGNS and ACCESSORIES sections Pressure side casing connection Casing material: PPs, PVC, PE, PEX, PP, PPsX, PVDF ABD 5 5 R, welded Ø6 Ø5 135 KOR RSF Ø6 Ø5 KOF Ø5 ELA + SPB Suction side casing connection Casing material: all USEG F KOF ELA SPB Accessories SPS WS RS Ø888 Ø Ø0 Ø6 Ø5 Ø6 Ø5 Ø5 Ø5 x315 Ø225 ROE 1666 Condensate drain Casing material: all KSF KSV KSS Ø18 5 max Ø Ø1 88 Ø Ø 95 Ø

46 VRE 6 Diagrams Impeller type 731 Impeller type , , , ,6 U/min rpm 1,4 14 1, , , ,528 U/min rpm 1,4 14 1, , , , ,000 2 = 12 1,2 kg/m³ 2, , , ,000 00,000 00,000 00, , ,0 20 2,0 30 3,0 4, ,0, ,0,0 0, = 12 1,2 kg/m³ 0 2, , ,000 20, ,000, ,000, ,0 20 2,0 30 3,0 4, ,0 0, ,0 0,0,0 0 Impeller type , , , ,695 U/min rpm 1, ,4 14 1, ,000 Impeller materials: 46 2 = 12 1,2 kg/m³ 1, , , , ,000 00,000 00,000 00, ,3 04 0,4 05 0,5 1,0 20 2,0 30 3,0 4,0 40 5,0 50,0 0 PPs, PPsX, PVC, PVDF GFRP GfK CFRP CfK 20,0 0

47 VRE 6 Technical data MOTOR VARIANTS for standard motor 3~V/Hz (Data for other motor types eg single phase motors, pole changing motors or Ex motors on request) Fan type Speed rpm kw kw A kg db(a) db(a) D-total VRE 6/731W ) VRE 6/731W Level 2 5) VRE 6/731W14 1, Level 2 5) VRE 6/731W14 1,6 1) Level 2 5) VRE 6/733W ) VRE 6/733W Level 2 5) VRE 6/733W14 1, Level 2 5) VRE 6/733W14 1,528 1) Level 2 5) VRE 6/673W Level 2 VRE 6/673W Level 2 5) VRE 6/673W14 1, Level 2 5) VRE 6/673W14 1,695 1) Level 2 5) 1) - during operation with frequency converter > Hz L A3m = A - evaluated noise level at a distance of 3 m 2) - Fan does not fall within scope of ErP directive L WA = A - evaluated noise level in the channel 3) - Fan for moving aggressive media 4) - When using IE2 motors 5) - When using IE3 motors 6) - When using IE4 motors Power requirement Nominal motor power Nominal motor current Weight with Motor L A3m L WA Octave level L WA-Okt / db(a) ErP category CASING POSITIONS The fan is available in casing positions L (left) and R (right), each in 6 different casing positions The position of the casing is set by the manufacturer and requires significant effort to change subsequently The axle height specified with casing position 0R in the dimension drawing remains unchanged 000L 045L 0L 135L 1L 225L Corresponding drawings in dxf format are available on the MIETZSCH CD 000R 045R 0R 135R 1R 225R 47

48 VRE 6 Technical data MAIN DIMENSIONS Casing position 0R Casing material: PPs, PVC, PE, PP, PPsX, PEX, PVDF for drive power: <= 45kW > 45 kw bis 75 kw Ø6 Ø ) ) VIBRATION ISOLATION The manufacturer equips all fans with a set of rubber insulators of type SP775-M that is designed for the size, speed and drive power of the fan Type SP775-M Ø Ø M FRAME / FLANGE Frame and flange are designed according to MIETZSCH standard MWS 5 or MWS 5 Drilling pattern: 0 undrilled (eg F0, KOF0) 1 hole pattern 1 for normal requirements (eg KOF1) 2 hole pattern 2 (double the number of screws) for high positive pressures and strong condensation (eg F2, KOF2) Frame R 6 5 Hole pattern 1 Hole pattern xØ x125 = xØ 34 4x75 = Models according to other standards or special designs are possible on request Flange F Ø6 Ø Ø674 16xØ Ø6 Ø Ø674 16xØ 48

49 ON VRE 6 Accessories CASING CONNECTIONS The basic model of the fan depicted under MAIN DIMENSIONS can be supplemented with a range of accessories and thus adapted optimally to the specific operating conditions In addition to the standard range, special models and even special designs are possible on request The variants shown in the dimension drawing therefore only cover the most frequently used casing connections and condensate drains For detailed information, refer to the SPECIAL DESIGNS and ACCESSORIES sections Pressure side casing connection Casing material: PPs, PVC, PE, PEX, PP, PPsX, PVDF ABD R, welded KOR Ø Ø6 Ø Ø6 Ø x315 8 ØØ0 Ø988 Ø6 Ø Ø Ø6 Ø Ø6 Ø6 135 RSF KOF Suction side casing connection Casing material: all USEG F KOF ELA + SPB Accessories SPS WS RS ELA + SPB ROE Condensate drain Casing material: all KSF KSV KSS Ø1 Ø Ø1 4xØ18 Ø Ø

50 VRE Diagrams Impeller type 731 Impeller type , , ,4 U/min rpm 1,4 14 1, , , ,3 U/min rpm 1, , , , ,000 2 = 1,2 12 kg/m³ 2, , , ,000 00,000 00,000 00, , ,0 20 2,0 30 3,0 4,0 40 5,0 50, ,0,0 0, = 12 1,2 kg/m³ 0 2, , ,000 20, ,000, , ,000 1,0 20 2,0 30 3,0 40 4,0 50 5,0 0, ,0 0,0,0 0 Impeller type , , , , ,695 U/min rpm 1,4 14 1, Impeller materials: 2 1, , , , ,000 00,000 00,000 00, ,3 04 0,4 05 0,5 1,0 20 2,0 30 3,0 4,0 40 5,0 50,0 0 PPs, PPsX, PVC, PVDF GFRP GfK CFRP CfK = 1,2 12kg/m³ 20,0 0

51 VRE Technical data MOTOR VARIANTS for standard motor 3~V/Hz (Data for other motor types eg single phase motors, pole changing motors or Ex motors on request) Fan type Speed rpm kw kw A kg db(a) db(a) D-total VRE /731W ) VRE /731W Level 2 5) VRE /731W14 1, Level 2 5) VRE /731W14 1,4 1) Level 2 5) VRE /733W ) VRE /733W ) VRE /733W9 1,3 1) Level 2 5) VRE /673W Level 2 VRE /673W Level 2 5) VRE /673W14 1, Level 2 5) VRE /673W14 1,4 1) Level 2 5) 1) - during operation with frequency converter > Hz L A3m = A - evaluated noise level at a distance of 3 m 2) - Fan does not fall within scope of ErP directive L WA = A - evaluated noise level in the channel 3) - Fan for moving aggressive media 4) - When using IE2 motors 5) - When using IE3 motors 6) - When using IE4 motors Power requirement Nominal motor power Nominal motor current Weight with Motor L A3m L WA Octave level L WA-Okt / db(a) ErP category CASING POSITIONS The fan is available in casing positions L (left) and R (right), each in 6 different casing positions The position of the casing is set by the manufacturer and requires significant effort to change subsequently The axle height specified with casing position 0R in the dimension drawing remains unchanged 000L 045L 0L 135L 1L 225L Corresponding drawings in dxf format are available on the MIETZSCH CD 000R 045R 0R 135R 1R 225R 51

52 VRE Technical data MAIN DIMENSIONS Casing position 0R Casing material: PPs, PE, PPsX, PVC, PEX, PP, PVDF for drive power: <= 37kW > 37 kw bis kw Ø 1914 Ø VIBRATION ISOLATION The manufacturer equips all fans with a set of rubber insulators of type SP775-M that is designed for the size, speed and drive power of the fan Type SP775-M Ø Ø M FRAME / FLANGE Frame and flange are designed according to MIETZSCH standard MWS 5 or MWS 5 Hole pattern 1 Hole pattern xØ xø Drilling pattern: 0 undrilled (eg F0, KOF0) 1 hole pattern 1 for normal requirements (eg KOF1) 2 hole pattern 2 (double the number of screws) for high positive pressures and strong condensation (eg F2, KOF2) Models according to other standards or special designs are possible on request Frame R Ø x75 = x75 = 20 Ø Flange F Ø Ø754 18xØ Ø Ø754 36xØ 52

53 ON VRE Accessories CASING CONNECTIONS The basic model of the fan depicted under MAIN DIMENSIONS can be supplemented with a range of accessories and thus adapted optimally to the specific operating conditions In addition to the standard range, special models and even special designs are possible on request The variants shown in the dimension drawing therefore only cover the most frequently used casing connections and condensate drains For detailed information, refer to the SPECIAL DESIGNS and ACCESSORIES sections Pressure side casing connection Casing material: PPs, PVC, PE, PEX, PP, PPsX, PVDF Ø7 Ø ABD Suction side casing connection Casing material: all USEG F KOF ELA + SPB Accessories SPS WS RS x Ø7 Ø Ø RSF KOF ELA + SPB KORR R, welded KOR Ø0Ø1120 Ø14 Ø7 Ø Ø7 Ø Ø Ø Ø ROE 11 Condensate drain Casing material: all KSF KSV KSS Ø1 Ø 4 Ø1 4xØ18 Ø Ø

54 VRE 0 Diagrams Impeller type 731 Impeller type 733 5, , ,325 U/min rpm 1,0 9 5, , ,2 U/min rpm 1, , , , ,000 2 = 12 1,2 kg/m³ 2, ,000 5, ,000 00,000 00,000 00, , ,0 20 2,0 30 3,0 40 4,0 5,0 50 0, ,0 0,0 0,0 175 = 12 1,2 kg/m³ 2, ,000 5, ,000 00,000,000 00, , ,0 20 2,0 30 3,0 40 4,0 50 5,0 0, ,0 0,0 0,0 Impeller type 673 5, , , ,3 U/min rpm 1, ,000 0 Impeller materials: = 1,2 12 kg/m³ 2, , , , ,000,000 00, , ,0 20 2,0 30 3,0 40 4,0 50 5,0 0, ,0 0,0 PPs, PPsX, PVC, PVDF GFRP GfK CFRP CfK 0,0

55 VRE 0 Technical data MOTOR VARIANTS for standard motor 3~V/Hz (Data for other motor types eg single phase motors, pole changing motors or Ex motors on request) Fan type Speed rpm kw kw A kg db(a) db(a) D-total VRE 0/731W Level 2 VRE 0/731W Level 2 5) VRE 0/731W9 1,325 1) Level 2 5) VRE 0/733W ) VRE 0/733W ) VRE 0/733W9 1,2 1) Level 2 5) VRE 0/673W Level 2 VRE 0/673W Level 2 5) VRE 0/673W9 1,3 1) Level 2 5) 1) - during operation with frequency converter > Hz L A3m = A - evaluated noise level at a distance of 3 m 2) - Fan does not fall within scope of ErP directive L WA = A - evaluated noise level in the channel 3) - Fan for moving aggressive media 4) - When using IE2 motors 5) - When using IE3 motors 6) - When using IE4 motors Power requirement Nominal motor power Nominal motor current Weight with Motor L A3m L WA Octave level L WA-Okt / db(a) ErP category CASING POSITIONS The fan is available in casing positions L (left) and R (right), each in 6 different casing positions The position of the casing is set by the manufacturer and requires significant effort to change subsequently The axle height specified with casing position 0R in the dimension drawing remains unchanged 000L 045L 0L 135L 1L 225L Corresponding drawings in dxf format are available on the MIETZSCH CD 000R 045R 0R 135R 1R 225R 55

56 VRE 0 Technical data MAIN DIMENSIONS Casing position 0R Casing material: PPs, PVC, PE, PP, PPsX, PEX, PPsX, PVDF for drive power: <= 37kW > 37 kw bis 132 kw Ø0 Ø VIBRATION ISOLATION The manufacturer equips all fans with a set of rubber insulators of type SP775-M that is designed for the size, speed and drive power of the fan Type SP775-M Ø Ø M FRAME / FLANGE Frame and flange are designed according to MIETZSCH standard MWS 5 or MWS 5 Drilling pattern: 0 undrilled (eg F0, KOF0) 1 hole pattern 1 for normal requirements (eg KOF1) 2 hole pattern 2 (double the number of screws) for high positive pressures and strong condensation (eg F2, KOF2) Frame R Hole pattern 1 Hole pattern x125 =375 28xØ 52 3x125 = x75 37 = x75 = xØ Models according to other standards or special designs are possible on request Flange F Ø0 Ø8 Ø844 20xØ Ø0 Ø8 Ø844 xø 56

57 ON VRE 0 Accessories CASING CONNECTIONS The basic model of the fan depicted under MAIN DIMENSIONS can be supplemented with a range of accessories and thus adapted optimally to the specific operating conditions In addition to the standard range, special models and even special designs are possible on request The variants shown in the dimension drawing therefore only cover the most frequently used casing connections and condensate drains For detailed information, refer to the SPECIAL DESIGNS and ACCESSORIES sections Pressure side casing connection Casing material: PPs, PVC, PE, PEX, PP, PPsX, PVDF Ø8 Ø0 ABD 514 RSF Ø8 Ø0 643 KOF Ø0 Condensate drain Casing material: all KSF KSV KSS Ø63 Ø165 Ø125 4xØ18 Ø63 Ø ELA + SPB KORR R, welded Suction side casing connection Casing material: all USEG F KOF ELA + SPB Accessories SPS WS RS x KOR Ø0Ø12 Ø1234 Ø8 Ø0 Ø8 Ø0 Ø0 Ø0 Ø2 ROE

58 VRE 0 Diagrams Impeller type 731 Impeller type 733 5, , ,175 U/min rpm 9 9 5, , ,020 U/min rpm , , , , = 12 1,2 kg/m³ 2, , , ,000 00,000 00,000 00, , ,0 20 2,0 30 3,0 40 4,0 50 5,0 0, ,0 0,0 0,0 155 = 12 1,2 kg/m³ 2, , , , ,000,000 00, , ,0 20 2,0 30 3,0 40 4,0 50 5,0 0, ,0 0,0 0,0 Impeller type 673 5, , , ,1 U/min rpm ,000 0 Impeller materials: 58 1 = 12 1,2 kg/m³ 2, , , , ,000,000 00, , ,0 20 2,0 30 3,0 40 4,0 50 5,0 0, ,0 0,0 PPs, PPsX, PVC, PVDF GFRP GfK CFRP CfK 0,0

59 VRE 0 Technical data MOTOR VARIANTS for standard motor 3~V/Hz (Data for other motor types eg single phase motors, pole changing motors or Ex motors on request) Fan type Speed rpm kw kw A kg db(a) db(a) D-total VRE 0/731W Level 2 VRE 0/731W Level 2 5) VRE 0/731W9 1,175 1) Level 2 5) VRE 0/733W ) VRE 0/733W Level 2 5) VRE 0/733W9 1,020 1) Level 2 5) VRE 0/673W Level 2 VRE 0/673W Level 2 5) VRE 0/673W9 1,1 1) Level 2 5) 1) - during operation with frequency converter > Hz L A3m = A - evaluated noise level at a distance of 3 m 2) - Fan does not fall within scope of ErP directive L WA = A - evaluated noise level in the channel 3) - Fan for moving aggressive media 4) - When using IE2 motors 5) - When using IE3 motors 6) - When using IE4 motors Power requirement Nominal motor power Nominal motor current Weight with Motor L A3m L WA Octave level L WA-Okt / db(a) ErP category CASING POSITIONS The fan is available in casing positions L (left) and R (right), each in 6 different casing positions The position of the casing is set by the manufacturer and requires significant effort to change subsequently The axle height specified with casing position 0R in the dimension drawing remains unchanged 000L 045L 0L 135L 1L 225L Corresponding drawings in dxf format are available on the MIETZSCH CD 000R 045R 0R 135R 1R 225R 59

60 VRE 0 Technical data MAIN DIMENSIONS Casing position Casing material: for drive power: 0R PPs, PE, PVC, PEX, PP, PPsX, PVDF kw bis 132 kw Ø VIBRATION ISOLATION The manufacturer equips all fans with a set of rubber insulators of type SP775-M that is designed for the size, speed and drive power of the fan Type SP775-M Ø Ø M FRAME / FLANGE Frame and flange are designed according to MIETZSCH standard MWS 5 or MWS 5 Drilling pattern: 0 undrilled (eg F0, KOF0) 1 hole pattern 1 for normal requirements (eg KOF1) 2 hole pattern 2 (double the number of screws) for high positive pressures and strong condensation (eg F2, KOF2) Models according to other standards or special designs are possible on request Frame R Flange F x125 = Hole pattern 1 Hole pattern Ø x125 =375 xø 20 Ø0 Ø x75 = xØ x75 = Ø0 Ø0 Ø9 xø 20xØ

61 ON VRE 0 Accessories CASING CONNECTIONS The basic model of the fan depicted under MAIN DIMENSIONS can be supplemented with a range of accessories and thus adapted optimally to the specific operating conditions In addition to the standard range, special models and even special designs are possible on request The variants shown in the dimension drawing therefore only cover the most frequently used casing connections and condensate drains For detailed information, refer to the SPECIAL DESIGNS and ACCESSORIES sections Pressure side casing connection Casing material: PPs, PVC, PE, PEX, PP, PPsX, PVDF Ø0 Ø0 RSF Ø0 Ø0 KOF Ø0 ELA + SPB KORR R, welded Suction side casing connection Casing material: all USEG F KOF ELA + 13 SPB Accessories SPS WS RS x KOR Ø0Ø1 Ø1384 Ø0 Ø0 Ø0 Ø0 Ø0 Ø0 Ø2 ROE Condensate drain 182 Casing material: all KSF KSV KSS Ø63 Ø165 4 Ø125 4xØ18 Ø63 Ø

62 VRE 0 Diagrams Impeller type 731 Impeller type 733 5, , , ,000 U/min rpm , , , U/min rpm , ,000 1 = 12 1,2 kg/m³ 2, , ,000, ,000 00,000, , ,000 2,0 3,0 20 4,0 5,030 40, ,0,0 200,0 0,0 0 1 = 12 1,2 kg/m³ 5, , ,000,000 00, , , ,0 30 3,0 40 4,0 5,0 50, ,0,0 0,0 0,0 0 Impeller type , , , ,000 9 U/min rpm 6 0 1,000 Impeller materials: 62 1 = 1,2 12 kg/m³ 2, ,000 5, ,000 00,000,000 00, , ,0 20 2,0 30 3,0 40 4,0 5,0 50, ,0 0,0 PPs, PPsX, PVC, PVDF GFRP GfK CFRP CfK,0 0

63 VRE 0 Technical data MOTOR VARIANTS for standard motor 3~V/Hz (Data for other motor types eg single phase motors, pole changing motors or Ex motors on request) Fan type Speed rpm kw kw A kg db(a) db(a) D-total VRE 0/731W Level 2 VRE 0/731W Level 2 5) VRE 0/731W9 1,000 1) Level 2 5) VRE 0/733W ) VRE 0/733W 855 1) ) VRE 0/673W Level 2 VRE 0/673W 9 1) Level 2 4) 1) - during operation with frequency converter > Hz L A3m = A - evaluated noise level at a distance of 3 m 2) - Fan does not fall within scope of ErP directive L WA = A - evaluated noise level in the channel 3) - Fan for moving aggressive media 4) - When using IE2 motors 5) - When using IE3 motors 6) - When using IE4 motors Power requirement Nominal motor power Nominal motor current Weight with Motor L A3m L WA Octave level L WA-Okt / db(a) ErP category CASING POSITIONS The fan is available in casing positions L (left) and R (right), each in 6 different casing positions The position of the casing is set by the manufacturer and requires significant effort to change subsequently The axle height specified with casing position 0R in the dimension drawing remains unchanged 000L 045L 0L 135L 1L 225L Corresponding drawings in dxf format are available on the MIETZSCH CD 000R 045R 0R 135R 1R 225R 63

64 VRE 0 Technical data MAIN DIMENSIONS Casing position Casing material: for drive power: 0R PPs, PVC, PE, PEX, PP, PPsX, PVDF kw bis 132 kw Ø VIBRATION ISOLATION The manufacturer equips all fans with a set of rubber insulators of type SP775-M that is designed for the size, speed and drive power of the fan Type SP775-M Ø Ø M FRAME / FLANGE Frame and flange are designed according to MIETZSCH standard MWS 5 or MWS 5 Drilling pattern: 0 undrilled (eg F0, KOF0) 1 hole pattern 1 for normal requirements (eg KOF1) 2 hole pattern 2 (double the number of screws) for high positive pressures and strong condensation (eg F2, KOF2) Models according to other standards or special designs are possible on request Frame R Flange F x125 = Hole pattern 1 Hole pattern xØ Ø x75 1 = Ø0 3x125 = Ø Ø0 54xØ 58 6x75 = Ø1 Ø 48xØ 24xØ 64

65 ON VRE 0 Accessories CASING CONNECTIONS The basic model of the fan depicted under MAIN DIMENSIONS can be supplemented with a range of accessories and thus adapted optimally to the specific operating conditions In addition to the standard range, special models and even special designs are possible on request The variants shown in the dimension drawing therefore only cover the most frequently used casing connections and condensate drains For detailed information, refer to the SPECIAL DESIGNS and ACCESSORIES sections Pressure side casing connection Casing material: PPs, PVC, PE, PEX, PP, PPsX, PVDF 614 Ø1 Ø0 RSF Ø1 Ø0 743 KOF Ø0 733 ELA + SPB KORR R, welded Suction side casing connection Casing material: all USEG F KOF ELA + SPB Condensate drain Casing material: all KSF KSV KSS Ø63 Ø165 Ø125 4xØ18 Ø63 Ø Accessories SPS WS RS 12 x KOR Ø1120Ø1 Ø1384 Ø1 Ø0 Ø1 Ø0 Ø0 Ø0 ROE Ø

66 Special designs Soundproof casing The installation situation can necessitate measures to reduce the noise level of the fan Soundproofing measures on the building side or encasing the fan with a soundproof capsula are not always possible To reduce the measuring surface sound pressure level by 7 dba, a soundproof casing can be used on request To this end, the casing is covered completely in a layer of mineral wool or soundproofing foam, which is covered in plastic in accordance with the casing material to protect it from damage or moisture Casings made of glass fibre reinforced plastic (GFRP) Due to the operating conditions, use of thermoplastics might not be possible, but at the same time, plastics are required for the components that come into contact with the medium to ensure resistance to chemicals In these cases, the casing as well as the impeller can be made of glass fibre reinforced plastics based on vinylester and epoxy resin For use in explosion hazard areas, these can be coated with a conductive chemical protection layer so that use in hazard areas of zone 1 is possible (see The technology explained, page 05) The casing is connected via a flange or frame (pressure side as of size 315) and compensators with the double-sided flange or frame Additional connecting parts are available on request 66

67 Accessories Splinter protection SPS and SPSG The VRE fans have been dimensioned safely on the basis of many years of experience An accident is almost impossible if all operating conditions are observed If impermissible operation cannot be avoided with sufficient certainty, eg due to caked on deposits on the impeller or impact of foreign bodies, you must use splinter protection A soft PVC foil placed around the casing jacket reduces environmental hazards due to splinters in case the impeller is destroyed Ordering information: SPS - splinter protection made of PVC foil SPSG - splinter protection made of PVC foil with additional wire mesh Additional safety can be achieved by reinforcing the casing jacket with glass-fibre reinforced plastic (GFRP) Cleaning hatch ROE For cleaning, the fan is removed from the plant and the intake connector is opened For large fans and high pollution, maintenance work can be reduced by means of an additional cleaning hatch in one or both sides of the casing or the jacket of the casing (see image above) Ordering information: ROE cleaning hatch Position (suction side, motor side, jacket + degree specification, see page 07) Weather protection WS for the motor By default, motors with protection level IP 55 are used, which are protected from hose water from all directions When installing fans outside, additional weather protection against all types of weather should be installed D Cleaning hatch (Opening Ø D ) Splinter protection Cleaning opening Fan size Casing Side Coat VRE - Ø1 VRE 2 - Ø1 VRE 315 Ø1 2x VRE Ø1 2x VRE 4 Ø1 2x VRE Ø1 x315 VRE 5 6 Ø225 x315 VRE 0 Ø2 x Weather protection Ordering information: WS - weather protection Condensate drain KSS / KSV / KSF Every fan has a condensate drill hole with a sealing cap at its lowest point Various nozzles for installing a condensate hose are available on request Ordering information: KSS - condensate nozzles Ø 22 for 3/4 hose KSV - condensate nozzles with screw connection EPDM seals KSF - condensate nozzles with flange ISO/DIN 21 PN KSB - condensate drill hole: Ø 145 Cleaning opening Fan size Ø D VRE 20 VRE 1 25 VRE VRE 5 VRE 6 VRE Ø 22 ØD ØD KSS KSV KSF 67

68 Electrical accessories Repair switch RS The RS switch is used to completely disconnect the fan from the grid for maintenance and repair work This ensures there is no risk of accidents due to uncontrolled activation The switch is delivered either loose or mounted and wired to the fan The size of the switch is determined by the engine power and the mains voltage Repair switch Switching capacity / kw three-pole Type 3(1)x2V 3xV 3x6V (for single-phase and RS ,5 7,5 three-phase motors) RS ,5 with auxiliary contact RS key-locked RS degree of protection IP 65 RS3-45 If the fan is connected via a frequency converter, the cable connection is shielded For pole changing motors, 6-pole switches are used For explosion protected fans, switches with EX protection EEX de IICT6 are used in accordance with ATEX Motor protection switch MS Connect each motor to the mains supply with a reactivation block Protection switches of type MS are three-pole low voltage switching devices and are used for single phase and three-phase motors They protect the engine from impermissible overloading and are used for operational switching of the fan The switch is delivered either loose or mounted and wired It is set for the respective nominal motor power Type Currant range / A MS 0,6 1,0 MS 16 1,0 1,6 Motor protection switch MS 25 1,6 2,5 three-pole MS 40 2,5 4,0 (for single-phase and MS 63 4,0 6,3 three-phase motors) MS 0 6,3 degree of protection IP 54 MS MS MS MS MS 0 32 For pole-changing motors, a switch is required for each speed For explosion protected fans, switches with EX protection EEX de IICT6 are used in accordance with ATEX Frequency converter FU A31 By utilising its numerous functions and with some additional components, many simple control tasks can be solved very easily with frequency converter FU A31 Based on this frequency converter, MIETZSCH supplies individual applications such as speed setting using a potentiometer, staggered operation, timer switching, pressure or volumetric flow control etc The user receives a complete system (fan, converter, switches, indicator lamps, measuring equipment, sensors, etc) which is immediately ready for operation after electrical connection All the necessary settings and programming are implemented at the factory Example: Volumetric flow control with alarm when the flow falls below the threshold Alarm unit Fan FU A31 with main switch and setpoint potentiometer Protection class IP Metering orifice with pressure transmitter

GmbH Lufttechnik Dresden USER INFORMATION RADIAL FANS. SERIES VRE direct driven. Issue 09/06

GmbH Lufttechnik Dresden USER INFORMATION RADIAL FANS. SERIES VRE direct driven. Issue 09/06 GmbH Lufttechnik Dresden USER INFORMATION RADIAL FANS SERIES VRE 560 direct driven Issue 09/06 s Series VRE VRE 560 direct driven Application in all s of ventilation High chemical resistivity by the use

More information

GmbH Lufttechnik Dresden USER INFORMATION ROOF FANS SERIES VRV. vertical outlet. Issue 10/17

GmbH Lufttechnik Dresden USER INFORMATION ROOF FANS SERIES VRV. vertical outlet. Issue 10/17 GmbH Lufttechnik Dresden USER INFORMATION ROOF FANS SERIES VRV vertical outlet Issue 10/17 Roof fans made of plastic materials Series VRV with vertical outlet Usable in ventilation engineering of all branches

More information

GmbH Lufttechnik Dresden USER INFORMATION ROOF FANS SERIES VRV. vertical outlet. Issue 07/02

GmbH Lufttechnik Dresden USER INFORMATION ROOF FANS SERIES VRV. vertical outlet. Issue 07/02 GmbH Lufttechnik Dresden USER INFORMATION ROOF FANS SERIES VRV vertical outlet Issue 07/02 Roof fans made of plastic materials Series VRV with vertical outlet Usable in ventilation engineering of all branches

More information

Small centrifugal fans made of plastic

Small centrifugal fans made of plastic Small centrifugal fans made of plastic durable application-optimised wide range of variants 2 Small centrifugal fans made of plastic Index Small centrifugal fans made of plastic HF R 75-16 D and HF R 110-18

More information

Centrifugal fan with highly efficient EC drive motor

Centrifugal fan with highly efficient EC drive motor Centrifugal fan with highly efficient EC drive motor simple and safe application and installation 2 Why HLU? 90 years of experience in the plastics processing market More than 10.000 m² production in Germany

More information

Powerful centrifugal fans for universal use: The product ranges TEM and REM

Powerful centrifugal fans for universal use: The product ranges TEM and REM Powerful centrifugal fans for universal use: The product ranges TEM and REM The fan ranges TEM and REM offered by Nicotra Gebhardt do present a large fan programme of single inlet centrifugal fans which

More information

Powerful centrifugal fans for universal use: The product ranges TEM and REM

Powerful centrifugal fans for universal use: The product ranges TEM and REM Powerful centrifugal fans for universal use: The product ranges TEM and REM The fan ranges TEM and REM offered by Nicotra Gebhardt do present a large fan programme of single inlet centrifugal fans which

More information

Centrifugal performance characteristics with axial flow pattern: RADAX VAR

Centrifugal performance characteristics with axial flow pattern: RADAX VAR High pressure in-line mixed-flow fans RADAX VAR Centrifugal performance characteristics with axial flow pattern: RADAX VAR COMPACT PRESSURE-RESISTANT UNIVERSAL In their compact casing, the RADAX VAR impellers

More information

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig CENTRIFUGAL FANS HV VAC &

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig CENTRIFUGAL FANS HV VAC & hore nd Offsh arine an ms for Ma geration System & Refrig HV VAC & PRODUCT CATALOGUE CENTRIFUGAL FANS ! "# $ % & " ' (! ) * +,+( -../01..2 PRODUCT CATALOGUE 73-16 CENTRIFUGAL FANS CONTENT PAGE 1. CENTRIFUGAL

More information

SERIES R - MD MOR & GOR

SERIES R - MD MOR & GOR SERIES R - MD MOR & GOR CHARACTERISTICS OPTIONS Aluminium alloy construction Surface protection treatment (anodising, only for ATEX 2 versions) Available in monoblock execution (MOR) and with coupling

More information

supplied in Form (B) configuration. Airflow over Impeller- Motor.

supplied in Form (B) configuration. Airflow over Impeller- Motor. CYLINDRICAL CASED AXIAL FLOW FANS COMPACT Series TCBB-TCBT (Aluminium impellers) and TCFB-TCFT (Plastic impellers) NEW VERSIONS Description The S&P Cylindrical Cased Axial Fans feature, as the name suggests,

More information

MAJAX-2 GENERAL SPECIFICATION

MAJAX-2 GENERAL SPECIFICATION MAJAX-2 GENERAL SPECIFICATION Majax-2 axial flow fans are manufactured in diameters ranging from 315mm to 2000mm (available in 2250mm on request), and incorporate manually adjustable pitch aluminium bladed

More information

Short casing. Long casing (L version) Commercial premises

Short casing. Long casing (L version) Commercial premises CYLINDRICAL CASED AXIAL FLOW FANS TGT Series Adjustable Pitch Fans Long casing (L version) Short casing A P P L I C A T I O N S Range of adjustable pitch cased axial flow fans. Casings formed from rolled

More information

Specifications. Applications Ventilation of safety cabinets (STORM 10), scrubbers, fume capture arms, filter housing, etc. (STORM 12, 14, 16).

Specifications. Applications Ventilation of safety cabinets (STORM 10), scrubbers, fume capture arms, filter housing, etc. (STORM 12, 14, 16). Specifications Applications Ventilation of safety cabinets (STORM 10), scrubbers, fume capture arms, filter housing, etc. (STORM 12, 14, 16). Housings: PP* Single block strong high density UV treated and

More information

ROOFMASTER STEF-ATEX ROOF FAN

ROOFMASTER STEF-ATEX ROOF FAN Air Comfort Air movement Roof fans ROOFMASTER STEF-ATEX ROOF FAN» Technical CATALOGuE 2 STEF-ATEX Roofmaster - Technical Catalogue Contents General description Application/specification... 3 Features...

More information

Explosion and flame-proof cast iron electric motors

Explosion and flame-proof cast iron electric motors Explosion and flame-proof cast iron electric motors EEx-d, EEx-de, IIB, IIC II, 2G IP55 II, 2G&D IP66 T4, T5, T6 Frame size 56 to 160 3 phases Voltage 230/400 V 50Hz Voltage 265/460V 60Hz Types of mounting

More information

DSA HIGH EFFICIENCY DROPLET SEPARATOR DROPLET SEPARATOR DSA. With heated vanes

DSA HIGH EFFICIENCY DROPLET SEPARATOR DROPLET SEPARATOR DSA. With heated vanes DSA MATERIALS HIGH EFFICIENCY DROPLET SEPARATOR With heated vanes PART MATERIAL FINISHING Droplet separator Aluminium EN AW 6060 - Frame Aluminium EN AW 5754 Painted RAL9010, C5-M as standard* Frame Heating

More information

PAB Atex-certified centrifugal pumps

PAB Atex-certified centrifugal pumps 1 6036 EN PAB Atex-certified centrifugal pumps Technical data Delivery rate Q max = 305 l/min Delivery head H max = 20 m Temperature range 0 C to +60 C Quality Management DIN EN ISO 9001: 2008 Environmental

More information

MODEL INFORMATION CANNED MOTOR PUMP TYPE CAM HERMETIC

MODEL INFORMATION CANNED MOTOR PUMP TYPE CAM HERMETIC MODEL INFORMATION CANNED MOTOR PUMP TYPE CAM HERMETIC ... 3... 4 3000 rpm 50 Hz / 3600 rpm 60 Hz... 4... 5... 7 Modular pump / motor systems... 7 Materials...........................................................

More information

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE Roofmaster STEC non-insulated version - Technical Catalogue 3 CONTENTS GENERAL DESCRIPTION Application/specification...4 Features...4

More information

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalogue

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalogue CENTRIFLOW 3D plug fan WITH AC MOTOR >> Technical catalogue air comfort Centriflow 3D 2 GMEB CentriFlow 3D - Technical Catalogue Contents GENERAL Description and survey chart Application... 3 General Survey

More information

Category 1 (zone 0) covers areas, where there is a permanent or long lasting occurrence

Category 1 (zone 0) covers areas, where there is a permanent or long lasting occurrence Explosion proof fans General Systemair explosion proof fans have been developed to be used in effective supply and exhaust air systems allocated to category 2 (zone 1) and category 3 (zone 2) in explosion

More information

AC Commercial Fans Edition. ErP ready

AC Commercial Fans Edition. ErP ready AC Commercial Fans 213 Edition ErP ready AC Commercial Fans Axair Fans UK Ltd / 1782 34943 About Axair Fans UK Axair is an independent industrial fan manufacturer and distributor. What we offer : Application

More information

LEF/MEF LEX/MEX ATEX versions

LEF/MEF LEX/MEX ATEX versions Fan LEF/MEF 250-630 - LEX/MEX ATEX versions GEOVENT centrifugal fan LEX and MEX with closed backward curving B-wheel and directly driven flange motor. The fan is used for extraction within the industry

More information

Centrifugal Fans ADH belt driven. Issue 2.5 EN August 2013

Centrifugal Fans ADH belt driven. Issue 2.5 EN August 2013 Centrifugal Fans ADH belt driven Issue 2.5 EN August 2013 1 AMCA Nicotra Gebhardt S.p.A. (Italy) certifies that ADH-E fans of the E0, E2, E4, E6 and E7 versions, from sizes 0160 to 0560, RDH-E fans of

More information

Duct mounted fans. axial flow. Pacific HVAC Engineering Tel. Australia NZ

Duct mounted fans. axial flow. Pacific HVAC Engineering Tel. Australia NZ Duct mounted fans axial flow Pacific HVAC Engineering 215 www.pacifichvac.com Tel. Australia 13 733 833 NZ 8 1 326 6 5 4 3 2 1 5 1 15 2 7 6 5 4 3 2 1 3 2.5 2 1.5 1.5 1 15.5 1 1.5 2 2.5 3 3.5 Volume m 3

More information

Technical brochure. LTG Fans. Tangential fans Type GA 25 / TA 40. Impeller diameter 25 mm / 40 mm.

Technical brochure. LTG Fans. Tangential fans Type GA 25 / TA 40. Impeller diameter 25 mm / 40 mm. Technical brochure LTG Fans Tangential fans Type GA 25 / TA 40 Impeller diameter 25 mm / 40 mm www.ltg.net LTG Process Air Technology LTG Fans LTG Filtration Technology LTG Humidification Technology Content

More information

Table of contents. Three-phase asynchronous motors DA

Table of contents. Three-phase asynchronous motors DA be in motion be in motion AC Asynchronous Motors DA 100-280 Table of contents 1. Three-phase asynchronous motor DA 100-280... 3 1.1. General technical data... 3 1.2. Ratings definition for ventilated

More information

MegaBox Product-specific information

MegaBox Product-specific information MegaBox Product-specific information Application Noise-encapsulating centrifugal fans with retractable motor impeller unit and motor located outside the air flow Suitable for rough operating conditions

More information

Explosion and flame-proof single phase electric motors

Explosion and flame-proof single phase electric motors Explosion and flame-proof single phase electric motors EEx-d, EEx-de, IIB, IIC II, 2G IP55 II, 2G&D IP66 T4, T5, T6 Frame size 56 to 112 Single phase Voltage 230 50Hz Voltage 265 60Hz Types of mounting

More information

Work area: Max. pressure: 2,150Pa Max. air volume: 2.100m³/h. Manufacturer. Production year. Model number/type. page

Work area: Max. pressure: 2,150Pa Max. air volume: 2.100m³/h. Manufacturer. Production year. Model number/type. page Centrifugal fan with closed fan wheel that is used at source extraction from air pollulant or chip making work processes. The transported air may not contain adhestive or sticky fumes or dust. Work area:

More information

Roof Extract Fans DV Ventilation Hoods DLH Smoke Extract Fans ER

Roof Extract Fans DV Ventilation Hoods DLH Smoke Extract Fans ER Roof Extract Fans DV Ventilation Hoods DLH Smoke Extract Fans ER Roof Extract Fans Ventilation Hoods Smoke Extract Fans DV DLH ER Summary... Seite Roof Extract Fans DV Product review... Summary data sheet...

More information

GigaBox centrifugal fans Product specific information

GigaBox centrifugal fans Product specific information GigaBox centrifugal fans Product specific information GigaBox and accessories Wall bracket GB-WK (ccessories) Outdoor cover hood GB-WSD (ccessories) Included in delivery: a) Flexible sleeve b) Outlet spigot,

More information

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalouge

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalouge CENTRIFLOW 3D plug fan WITH AC MOTOR >> Technical catalouge air comfort Centriflow 3D 2 GMEB CentriFlow 3D - Technical Catalouge Contents GENERAL Description and survey chart Application... 3 General Survey

More information

Tangential Fans Series TM and TMt Impeller Diameter 125 and 150 mm (4.92" and 5.9")

Tangential Fans Series TM and TMt Impeller Diameter 125 and 150 mm (4.92 and 5.9) Tangential Fans Series TM and TMt Impeller Diameter 125 and 150 mm (4.92" and 5.9") 105 Corporate Drive, Suite E Spartanburg, SC 29303 PO Box 2889, Spartanburg, SC 29304 USA Tel: 864-599-6340 Fax: 864-599-6344

More information

AXIAL FANS Catalogue CN0050C01 May 2008

AXIAL FANS Catalogue CN0050C01 May 2008 ADTA AXIAL FANS Catalogue CN0050C01 May 2008 ADTA AXIAL FANS Catalogue CN0050C01 May 2008 Construction Specifications Impellers: Breezax aerfoil blades are available in four types of material: Glass Reinforced

More information

ROOFMASTER STEF-HT ROOF FAN

ROOFMASTER STEF-HT ROOF FAN fire safety Air movement Roof Fans ROOFMASTER STEF-HT ROOF FAN» Technical CATALOGuE Contents ROOFMASTER STEF-HT...3 Performance Data...4 Performance Table...5 General description...6 Fan Chart-explanation

More information

Industrial Mini Vent Sets

Industrial Mini Vent Sets Industrial Mini Vent Sets FRP Construction M I N I S E R I E S and Impellers Volume Range shut off up to 4000 (1888 l/sec) Static pressures up to 19 W.G. (4719 Pa) Industrial and Commercial Applications

More information

DTV, DTH and VVR Roof- and wall fans DTV Roof fan DTH Roof fan VVR Wall fan

DTV, DTH and VVR Roof- and wall fans DTV Roof fan DTH Roof fan VVR Wall fan Product information - Version 3 DTV, DTH and VVR Roof- and wall fans DTV Roof fan DTH Roof fan VVR Wall fan Overskrift placering Table of contents Choice of motor... 4 DTV roof fans... 5 - Technical specifications

More information

VORTICENT C E RANGE Centrifugal fans

VORTICENT C E RANGE Centrifugal fans NEW VORTICENT C E RANGE Centrifugal fans Suitable for domestic, commercial and industrial applications: kitchens, bathrooms, offices, laboratories, factories, shops, laundromats, models, restaurants, bars,

More information

VALIADIS S.A. HELLENIC MOTORS

VALIADIS S.A. HELLENIC MOTORS Explosion proof motors MAK 56-250 (MAKe 63-250) series Groups IIB and IIC Ex db / Ex db e (EPL) executions Gb or Ex tb IIIC (EPL) Db II 2 G, II 2D, 2GD SAFETY INSTRUCTIONS Safety Instructions MAK and MAKe

More information

Explanation of AR Series Ventilator Products. Fan type code D S AR AE

Explanation of AR Series Ventilator Products. Fan type code D S AR AE Series Axial Fan Explanation of Series Ventilator Products Fan type code 450-7 /26 D -2 F400 Smoke Extract Fan 400 C, 300 C Number of Poles D S Three Phase Single Phase AE AE Features and construction

More information

In-Line Fans. Roof Fans. Fans ATEX. Centrifugal Fans. Chip Extractors. Domestic Fans. Accessories. Electric Diagrams. General Information.

In-Line Fans. Roof Fans. Fans ATEX. Centrifugal Fans. Chip Extractors. Domestic Fans. Accessories. Electric Diagrams. General Information. In-Line Fans xial-flow Fans Wall Versions xial-flow Fans Cased Versions Roof Fans Fans TEX Centrifugal Fans VISP/VSP Centrifugal Fans Side Channel lowers Chip Extractors COMPCT 44 TCx, TCTx FC 54 FC-V

More information

Section 4. Axial Fans - Section 4

Section 4. Axial Fans - Section 4 Axial Flow Fans Section 4 Fläkt Woods offers a wide range of axial flow fans for general air movement and special applications such as emergency high temperature smoke extract and pressurisation. ATEX

More information

Centrifugal Fans RZR belt driven. Issue 2.5 EN August 2013

Centrifugal Fans RZR belt driven. Issue 2.5 EN August 2013 Centrifugal Fans RZR belt driven Issue 2.5 EN August 2013 1 AMCA Nicotra Gebhardt S.p.A. (Italy) certifies that ADH-E fans of the E0, E2, E4, E6 and E7 versions, from sizes 01 to 05, RDH-E fans of the

More information

For ATEX zone 1/1, 22/22 and 21/21. Work area: Max. pressure: 5,800Pa Max. air volume: 32,500m³/h

For ATEX zone 1/1, 22/22 and 21/21. Work area: Max. pressure: 5,800Pa Max. air volume: 32,500m³/h For ATEX zone 1/1, 22/22 and 21/21 Centrifugal fan with closed fan wheel that is used at source extraction from air pollulant or chip making work processes. The transported air may not contain adhestive

More information

CYLINDRICAL CASED AXIAL FLOW FANS

CYLINDRICAL CASED AXIAL FLOW FANS - Adjustable pitch fans Range of adjustable pitch aerofoil blade, cased axial flow fans. Casings formed from rolled sheet steel with a corrosion resistant hot dipped galvanised finish. All models incorporate

More information

CMRT Series BACKWARD CURVED CENTRIFUGAL FANS. Backward curved centrifugal fans CMRT 80 C

CMRT Series BACKWARD CURVED CENTRIFUGAL FANS. Backward curved centrifugal fans CMRT 80 C BACKWARD CURVED CENTRIFUGAL FANS CMRT Series 80 C Continuous operation Range of single inlet direct drive centrifugal fans designed for continuous extraction of air stream up to 80ºC. Casings are manufactured

More information

ACOUSTIC CABINET FANS CVB / CVT Series

ACOUSTIC CABINET FANS CVB / CVT Series Cabinet fans manufactured from heavy gauge galvanised steel sheet and internally lined with melamine foam flame retardant acoustic insulation (M1). All models incorporate double inlet single phase direct-drive

More information

CNA-CNB CNA-CNB CENTRIFUGAL FANS STANDARD TEMPERATURES AND EX

CNA-CNB CNA-CNB CENTRIFUGAL FANS STANDARD TEMPERATURES AND EX NA-NB NA-NB ENTRIFUGAL FANS STANDARD TEMPERATURES AND EX PRODUT FATS PRODUT The centrifugal fans type NA and NB are robust and versatile fans of the single-inlet type with backward-curved blades. APPLIATION

More information

ASA. SINGLE INLET CENTRIFUGAL FAN with Airfoil Wheels

ASA. SINGLE INLET CENTRIFUGAL FAN with Airfoil Wheels ASA SINGE INET ENTRIUGA AN with Airfoil heels ASA Series SINGE INET ENTRIUGA AN with Airfoil heels Kruger Ventilation Industries certifies that the ASA series shown herein is licensed to bear the AMA Seal.

More information

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX) X X testregistrierung CAV controllers Type Adjustment scale For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX) Rectangular, mechanical self-powered

More information

Pneumatic Axial Fan Type Tech. Doc. No. 802

Pneumatic Axial Fan Type Tech. Doc. No. 802 Pneumatic Axial Fan Type Tech. Doc. No. 802 Illustration can differ from the original Operation and Maintenance Manual Compiled: 06.08.13 815340300_en_Version_02 Page 1 of 11 ATTENTION!!! This pneumatic

More information

FAN & BLOWER CENTRIFUGAL FANS

FAN & BLOWER CENTRIFUGAL FANS FAN & BLOWR CNTRIFUGAL FANS INTRODUCTION GNRAL PRODUCT RANG FANS BY FANTCH - INTRACTIV PRODUCT SUIT SLCTION PROGRAM PRFORMANC CONSTRUCTION The Fan & Blower range of centrifugal fans is marketed to the

More information

TURBO PRESSURE BLOWERS

TURBO PRESSURE BLOWERS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS TURBO PRESSURE BLOWERS TBA TBR CATALOG 10 APRIL 13 TURBO PRESSURE BLOWERS Models TBA TBR TBR Arrangement 8 Model TBA and TBR fans from

More information

Operating instructions

Operating instructions Operating instructions Type TEKA filtoo TEKA Absaug- und Entsorgungstechnologie GmbH Industriestraße 13 D-46342 Velen Postfach 1137 D-46334 Velen Tel.: +49 (0) 2863 9282-0 Fax: +49 (0) 2863 9282-72 E-Mail:

More information

Technical data 50 & 60 Hz. Vertical centrifugal pumps Series: DPLHS

Technical data 50 & 60 Hz. Vertical centrifugal pumps Series: DPLHS Technical data 50 & 60 Hz Vertical centrifugal pumps Series: DPLHS 2 Table of Contents 1 Pump introduction 1.1 General... 4 1.2 Model key... 4 1.3 Description of the product... 4 1.4 Operation... 5 1.5

More information

ceiling swirl diffuser DQJ

ceiling swirl diffuser DQJ ceiling swirl diffuser DQJ Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Advantages...

More information

Battery Boxes Series 8316

Battery Boxes Series 8316 www.stahl.de > Back-up power supply > Maintenance-free batteries > Low self-discharge > Extremely low gas emissions > Electrolyte-tight > No acid surface coating > Protection against total disch arge >

More information

Sealless Magnetic Coupled Hot Oil Circulation Pumps acc. to DIN EN / ISO 2858 Type NMWR / NMWB / NMW. our. contribution for

Sealless Magnetic Coupled Hot Oil Circulation Pumps acc. to DIN EN / ISO 2858 Type NMWR / NMWB / NMW. our. contribution for Sealless Magnetic Coupled Hot Oil Circulation Pumps acc. to DIN EN 22858 / ISO 2858 Type NMWR / NMWB / NMW our contribution for environmental protection General DICKOW pumps of series NMWR / NMWB / NMW

More information

AXIAL FANS Axis / Tubo OPERATION MANUAL

AXIAL FANS Axis / Tubo OPERATION MANUAL TUBO-M AXIS-QA AXIS-Q AXIS-QR AXIS-F AXIS-QRA AXIAL FANS Axis / Tubo OPERATION MANUAL Axis / Tubo www.blaubergventilatoren.de CONTENT 3 Introduction 3 General 3 Safety rules 3 Transport and storage requirements

More information

Sealless magnetic coupled centrifugal pump Type NMR Design with heavy duty oil lubricated bearing bracket. our. contribution for

Sealless magnetic coupled centrifugal pump Type NMR Design with heavy duty oil lubricated bearing bracket. our. contribution for Sealless magnetic coupled centrifugal pump Type NMR Design with heavy duty oil lubricated bearing bracket our contribution for environmental protection GENERAL DICKOW-pumps of series NMR are sealless centrifugal

More information

RVP-R- VAV controller. In explosion-proof version

RVP-R- VAV controller. In explosion-proof version VAV controller In explosion-proof version RVP-R- SMAY LLC / 29 Ciep³ownicza St. / 31-587 Cracow / Poland tel. +48 12 378 18 00 / fax. +48 12 378 18 88 / e-mail: info@smay.eu Intended use VAV control units

More information

Mechanical mixing box MBM

Mechanical mixing box MBM Mechanical mixing box MBM Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telefon 0 74 63-980 - 0 Fax 0 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction... 3 Model...

More information

ARBO. ARBO Magnetic drive pumps. Pompen en Filters b.v. Product group 2.2

ARBO. ARBO Magnetic drive pumps. Pompen en Filters b.v. Product group 2.2 ARBO Pompen en Filters b.v. ARBO Magnetic drive pumps Product group 2.2 Product group 2.2 MagPro Working principle Magnetic drive pumps are Seal-less. The driving torque is transmitted by a permanent magnetic

More information

Product Overview. Rotary Encoders for Potentially Explosive Atmospheres (ATEX)

Product Overview. Rotary Encoders for Potentially Explosive Atmospheres (ATEX) Product Overview Rotary Encoders for Potentially Explosive Atmospheres (ATEX) December 2013 Rotary encoders for use in potentially explosive areas Introduction There are many types of applications in industry

More information

Lenze ATEX-compliant gearboxes Gearboxes for use in potentially explosive atmospheres

Lenze ATEX-compliant gearboxes Gearboxes for use in potentially explosive atmospheres Lenze ATEX-compliant gearboxes Gearboxes for use in potentially explosive atmospheres ATEX for drive technology The ATEX directive, which has been in force since July 1, 2003, has been introduced in an

More information

RIGIFLEX -N RADEX -N. Steel laminae coupling. Steel laminae coupling. You will find continuously updated data in our online catalogue at

RIGIFLEX -N RADEX -N. Steel laminae coupling. Steel laminae coupling. You will find continuously updated data in our online catalogue at 117 Table of contents 117 Coupling selection steel laminae coupling 119 Description of coupling 121 General information 122 Types and applications 123 Technical data 124 Standard types 126 Special types

More information

Centrifugal medium-pressure fans fitted with multi-blade

Centrifugal medium-pressure fans fitted with multi-blade CMP/ATEX CMP/ATEX impeller Centrifugal medium-pressure fans fitted with multi-blade with ATEX certification Centrifugal single-inlet, medium-pressure fans with casing and sheet steel impeller to work in

More information

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1 INLINE Flow sensor for hazardous area II G/D - II D - II GD - I M Type SE0 Ex can be combined with... Flow meter with NAMUR or NPN/PNP output signal Mounting, dismounting of electronics by a Quarter-Turn

More information

Vertical Sump Pump Type ETL

Vertical Sump Pump Type ETL Vertical Sump Pump Type ETL»dry running safe«technical data Flow rate Q up to 220 m 3 /h Head H up to 55 m Submersion depth 500 or 750 mm Suction extension up to 1800 mm Materials limits of use PP up to

More information

Hazardous areas, as found around a service station, are classified into three zones as follow: Table 1: Zone Classification for Vapours

Hazardous areas, as found around a service station, are classified into three zones as follow: Table 1: Zone Classification for Vapours MIE TALK - July 2016 Compiled by Pieter H. Coetzee Introduction Far too many fires and burn injuries result from the careless or inappropriate use of petrol. Because petrol is so common in our environment,

More information

IN-LINE RECTANGULAR FANS IRB / IRBS IRB

IN-LINE RECTANGULAR FANS IRB / IRBS IRB IN-LINE RECTANGULAR FANS IRB / IRBS IRB IN-LINE RECTANGULAR FANS IRB / IRBS IRB and IRBS are a compact series of centrifugal type exhaust and supply in-line duct fans for air conditioning systems. They

More information

better measurement Simply a question of

better measurement Simply a question of Simply a question of better measurement SCHMIDT Flow Sensor SS 2.415 and SS 2.515 The tried and tested measurement experts for the monitoring of laminar flows extremely precise and quickly installed Industrial

More information

Automatic metal-edge filter AF 75 S / AF 95 S

Automatic metal-edge filter AF 75 S / AF 95 S Automatic metal-edge filter AF 75 S / AF 95 S with radial scraper cleaning housing in welded design, optionally with cyclone effect Connection size DN 150, DN 200, DN 250 others upon request 1. Features

More information

Bifurcated Case Axial Fans (BIFA)

Bifurcated Case Axial Fans (BIFA) Bifurcated Case Axial Fans (BIFA) Sizes 250 to 1000 dia Motors protected to IP55 Motor insulation Class F Maximum ambient temperature 200 C Speed controllable via transformer or inverter (when the ambient

More information

Filter module AF Features. MAHLE Industrialfiltration is now Filtration Group. For more information, visit

Filter module AF Features. MAHLE Industrialfiltration is now Filtration Group. For more information, visit MAHLE Industrialfiltration is now Filtration Group. For more information, visit www.filtrationgroup.com Filter module AF 43 Nominal pressure 16 bar, nominal temperature 180 C; nominal width DN 80 to DN

More information

List Price. Mult. Sym. C Dim. Single Phase

List Price. Mult. Sym. C Dim. Single Phase Single and Three Phase, Foot Mounted Explosion Proof 1/4 thru 300 48 thru 449TY Applications: Ideal for use where hazardous fumes or dust may be present. Features: U.L. and CSA approved for Class I, Group

More information

1/4 thru 300 Hp NEMA 48 thru 449TY. List Price. Mult. Sym. C Dim. Single Phase

1/4 thru 300 Hp NEMA 48 thru 449TY. List Price. Mult. Sym. C Dim. Single Phase Single and Three Phase, Foot Mounted Explosion Proof 1/4 thru 300 48 thru 449TY Applications: Ideal for use where hazardous fumes or dust may be present. Features: U.L. and CSA approved for Class I, Group

More information

Circulation pumps BFP-ATEX-T3/T4

Circulation pumps BFP-ATEX-T3/T4 Circulation pumps BFP-ATEX-T3/T F ATEX - range of use: to zone 1 and zone 1 T3 to zone 1 and zone 1 T Low noise emission High vol. efficiency Optimum suction Gerotor principle Resistant to contamination

More information

ROOF MOUNTED AXIAL FLOW FANS HCTB / HCTT Series

ROOF MOUNTED AXIAL FLOW FANS HCTB / HCTT Series asy to install Supports to facilitate installation in the roof. XTRACTION (type B) SUPPLY (type A) High quality steel sleeve nsuring the long life of the fan. Range of axial roof fans with horizontal air

More information

Volute Casing Centrifugal Pumps PN 16 for heat-transfer liquids Heat-transfer oil up to 350 C Hot water up to183 C

Volute Casing Centrifugal Pumps PN 16 for heat-transfer liquids Heat-transfer oil up to 350 C Hot water up to183 C Volute Casing Centrifugal Pumps PN 16 for heat-transfer liquids Heat-transfer oil up to 350 C Hot water up to183 C Series CMIT in inline design Series CMAT with axial inlet ATEX 0 a Series CMAT Series

More information

Series VENTS KSK. Centrifugal kitchen fan in sound-insulated casing with air flow up to 8138 m 3 /h

Series VENTS KSK. Centrifugal kitchen fan in sound-insulated casing with air flow up to 8138 m 3 /h SOUND-INSULATED KITCHEN FAN Series device. The impeller is mounted on the motor shaft and is balanced statically and dynamically. The motor has F class motor winding insulation and ingress protection rating.

More information

Operating Instructions. VEGASWING 61, 63 with oscillator SW E60N (EX)

Operating Instructions. VEGASWING 61, 63 with oscillator SW E60N (EX) Operating Instructions VEGASWING 61, 63 with oscillator SW E60N (EX) Contents Contents Safety information... 2 Note Ex area... 2 1 Product description... 3 2 Function and application... 4 2.1 Principle

More information

Axial-flow Fan AFC. Model numbering system AF C / T. Accessories Three phase. Power rate 1.

Axial-flow Fan AFC. Model numbering system AF C / T. Accessories Three phase. Power rate 1. xial-flow Fan FC Construction xial fan designed for installation in a ducted system. Casing of rolled and electro-welded steel sheet, powder coated RL5. Impeller in polypropylene. Casing in acid-proof

More information

BSB. SINGLE INLET CENTRIFUGAL FAN with Backward Wheels

BSB. SINGLE INLET CENTRIFUGAL FAN with Backward Wheels BSB SINGE INET ENTRIFUGA FAN with Backward heels BSB Series SINGE INET ENTRIFUGA FAN with Backward heels Kruger Ventilation Industries certifies that the BSB series shown herein is licensed to bear the

More information

Additional operating instructions according to ATEX 94/9/EC Volumetric flow controller VM-PRO-Ex

Additional operating instructions according to ATEX 94/9/EC Volumetric flow controller VM-PRO-Ex Additional operating instructions according to ATEX 94/9/EC Volumetric flow controller VM-PRO-Ex Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telefon 0 74 63-980 - 0 Telefax 0 74 63-980 - 200

More information

Volute Casing Centrifugal Pumps in High Temperature Design with Magnetic Drive. Series CNH-ML

Volute Casing Centrifugal Pumps in High Temperature Design with Magnetic Drive. Series CNH-ML Volute Casing Centrifugal Pumps in High Temperature Design with Magnetic Drive Series CNH-ML Usage For pumping toxic, volatile, explosive or other fluids harmful to the environment which call for service

More information

Ultrasonic filling level sensor UFM 200 / 600 C2 / C4 / R / MD

Ultrasonic filling level sensor UFM 200 / 600 C2 / C4 / R / MD Ultrasonic filling level sensor UFM 200 / 600 C2 / C4 / R / MD Features UFM 600 up to 6 metres UFM 200 up to 2 metres for distance, volume and filling level measurement for containers, open basins or channels

More information

Dial thermometers. Gas filled system and Bi-metal. dial thermometers

Dial thermometers. Gas filled system and Bi-metal. dial thermometers JJ Dial thermometers JJ Diesel engine thermometers JJ Low temperature dial thermometers JJ Remote reading dial thermometers JJ Remote reading diesel engine thermometers JJ Remote reading low temperature

More information

ASV Eccentric Pumps Type F and Type L

ASV Eccentric Pumps Type F and Type L ASV Eccentric Pumps Type F and Type L»self-priming - dry running capable«technical data Type F Type L Flow rate Q up to 1,8 m 3 /h up to 5,2 m 3 /h Head H up to 25 m up to 25 m Suction height H max. 5

More information

Solenoid coil for control in potentially explosive areas Type BZ

Solenoid coil for control in potentially explosive areas Type BZ Data sheet Solenoid coil for control in potentially explosive areas Type BZ BZ is a solenoid coil with ATEX / IECEx approval, applicable for zone 1 and 2 Ex environments. The coils are designed to be used

More information

BPF. Centrifugal Plug Fans

BPF. Centrifugal Plug Fans BPF Centrifugal Plug Fans Introduction INTRODUCTION Plug Fans S&P - THE COMPANY Soler & Palau was founded in 1951 in Ripoll (Spain) and since this date has become one of the world s leading companies engaged

More information

ExpressBuild STANDARD FAN RANGE

ExpressBuild STANDARD FAN RANGE AIR COMFORT FIRE SAFETY ExpressBuild STANDARD FAN RANGE OUR SHORT LEAD TIME FAN RANGE ExpressBuild CONCEPT & PRINCIPLES When a short lead time solution is important, choose an ExpressBuild Fan product

More information

AAVC. Accessories HIGH PRESSURE FANS HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES:

AAVC. Accessories HIGH PRESSURE FANS HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES: AAVC HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES: Accessories Fan made of Fe360 sheet. The fan paint finish is based on a Qualicoat polyester powder coating stoved at 200ºC, with an average

More information

ATEX instruction for APP / PAH PAHT G 2-90 / PAH Tech

ATEX instruction for APP / PAH PAHT G 2-90 / PAH Tech MAKING MODERN LIVING POSSIBLE Instruction ATEX instruction for APP 0.6-10.2 / PAH 2-100 PAHT G 2-90 / PAH 25-80 Tech danfoss.high-pressurepumps.com Table of Contents 1. Common demands for Category 2 and

More information

Defining Innovation. turbo pressure blowers. Twin City Catalog 1200

Defining Innovation. turbo pressure blowers. Twin City Catalog 1200 Defining Innovation. turbo pressure blowers MODEL TBA TBR 1 Twin City Catalog CATALOG -A May 11 Model TBA/TBR Turbo Pressure Blowers Model TBA and TBR fans from Twin City Fan & Blower are constant pressure,

More information

IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems

IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems MIXVENT TD / MIXVENT TD-T MIXVENT TDx2 ACCESSORIES Description Range Construction The MIXVENT system has been designed to compliment the MIXVENT-TD range

More information

ACOUSTIC CABINET FANS Centribox CVB-CVT Series, Forward Curved Centrifugal Fans

ACOUSTIC CABINET FANS Centribox CVB-CVT Series, Forward Curved Centrifugal Fans Hacer título más resumido ACOUSTIC CABINET FANS Centribox CVB-CVT Series, Forward Curved Centrifugal Fans Construction Casing The fan casings are manufactured from heavy gauge galvanised sheet steel and

More information

Centrifugal Immersion Pumps

Centrifugal Immersion Pumps Centrifugal Immersion Pumps FLUX Centrifugal Immersion Pumps Quality that sets standards. Manufactured at our main plant, these ranges of immersion pumps are the result of extensive product and process

More information