Powerful centrifugal fans for universal use: The product ranges TEM and REM
|
|
- Eric McBride
- 6 years ago
- Views:
Transcription
1 Powerful centrifugal fans for universal use: The product ranges TEM and REM The fan ranges TEM and REM offered by Nicotra Gebhardt do present a large fan programme of single inlet centrifugal fans which are universally usable for many ventilation purposes either in HVAC or in machinery design industry and heavy duty installation business. The fans are available with forward curved impellers (TEM) or with impellers (REM) equipped with backward curved blades. The fans are equipped with IEC flanged (B5) standard s, protection IP55, class F, and they are suitable for frequency inverter controlled operation. Benefits: compact design because of direct drive cost effective by maintenance-free operation speed controlled by frequency inverter universally usable due to different options, such as without brackets as a directly fitted unit for operation with vertical shaft arrangement with brackets for operation with horizontal shaft ATEX execution for explosion hazardous areas and applications Fan range TEM rated - Ex II 3G c IIB T3 Fan range REM rated - Ex II 2G c IIB T3 264
2 Nicotra Gebhardt TEM and REM The universal technology for various applications! TEM ranges Sizes from 16 up to 355 Volume up to 9 also available in 6Hz execution also available in ATEX execution 3G with PTC in flange execution Impeller with forward curved blades For applications in HVAC-facilities, big kitchen or for clean room technologie. REM ranges Sizes from 2 up to 63 Volume up to 2, also in available 6Hz execution also available in ATEX execution 2G with PTC in flange execution Impeller with backward curved blades For applications in the filter technologie, drying- and suction plants. The ranges TEM and REM For every application, the suitable fan: Version Description Figure TEM 1-16/-355 Lap jointed scroll of galvanised sheet steel with discharge flange and built-in impeller with forward curved blades, without pedestal, for vertical or horizontal mounting. TEM 8-16/-355 Lap jointed scroll of galvanised sheet steel with discharge flange and built-in impeller with forward curved blades, with pedestal, for horizontal mounting. REM 11-2/-63 Lap jointed scroll of galvanised sheet steel with discharge flange and built-in impeller with backward curved aerofoil blades, without pedestal, for vertical or horizontal mounting. REM 18-2/-63 Lap jointed scroll of galvanised sheet steel with discharge flange and built-in impeller with backward curved aerofoil blades, with pedestal, for horizontal mounting. REM 13-2/-63 Scroll casing stitch welded with discharge flange, epoxy coated, built-in impeller with backward curved aerofoil blades, without pedestal, for vertical or horizontal mounting. REM 19-2/-63 Scroll casing stitch welded with discharge flange, epoxy coated, built-in impeller with backward curved aerofoil blades, with pedestal, for horizontal mounting. REM 41-2/-45 Lap jointed scroll of galvanised sheet steel with discharge flange and built-in impeller with backward curved blades, without pedestal, for vertical or horizontal mounting. REM 48-2/-45 Lap jointed scroll of galvanised sheet steel with discharge flange and built-in impeller with backward curved blades, with pedestal, for horizontal mounting. 265
3 Description Direct driven centrifugal fans / TEM/REM / Description Safety Performance data The fans are designed for installation in equipment and as standard are not equipped with protective guards. They should not be put into operation before all protective devices are fitted and connected! Protective measures must be carried out as set out in DIN EN ISO 121 "Safety of machinery - Basic concepts, general principles for design". If the application of the fan allows free access to the inlet and discharge apertures, safety devices must be put in place on the fan in accordance with DIN EN ISO 13857! Suitable safety guards are available as an optional extra. The performance curves of the fans are determined at the plenum test rig according to ISO 581, measured in installation "B". In the diagrams of all series, the total pressure increase and the dynamic pressure in relation to the flange crosssection at the discharge are represented in dependency on the. For closer determination of duty same unit performance curves (parabolas) are contained in the diagrams. The static pressure increase p sf with a connected discharge flange can be determined according to the following relation. p sf = All data are valid for the source density r 1 = 1,2kg/m³. Sound The noise measuring and evaluation is conducted according to DIN Noise measurement in machines: fans. In the diagrams the A-weighted sound power level of the fan is given on the performance curves as the emission. The A weighted sound power level are identical for fan intake (7 ) as well as for fan discharge (4 ). The A-weighted sound pressure level L pa7/6 at a distance of 1 m at fan Inlet or discharge can be approximately determined by the following formula: L pa6/7 ~ 4/7-7dB The sound power levels in the individual octavos can be taken from the electronic catalogue proselecta II. s Electric connection The series of centrifugal fans, with single inlet are designed for the use in air handling and ventilation installations. The fans are suitable for conveying air and other non aggressive gases. The temperatures admitted for the fluid are from -2 C to +6 C. Standard s of wellknown brands, type of protection IP55, thermal class F, are used. During commissioning and maintenance the detailed instructions provided by the manufacturer (type plate/ operating instructions) must be followed, this also applies to the protection devices required onsite. The s are equipped with PTC resistors/temperature sensors as standard. s with integrated frequency inverters may be supplied on request. The centrifugal fans are delivered ready for installation. The terminal box can be accessed easily. Electric installation must be carried out according to the applicable provisions in compliance with local regulations. A terminal board circuit diagram showing correct connection is enclosed with every. Updated circuit diagrams are also available online at In case of operation with frequency inverters, always follow the respective operating instructions! 328
4 Description Direct driven centrifugal fans / TEM/REM / Description Explosion protection according to ATEX Fans for use in explosive atmospheres must comply with EC Directive 94/9/EG (ATEX 95). Equipment in Group II (all applications except mining) is categorised in accordance with the required degree of safety for designated use in equipment categories 1, 2 and 3. Depending on suitability, a distinction is in addition made between G (gas, vapours) and D (dust). Harmonised European standards and national guidelines must be observed. Equipment in class 2 and 3 is not subject to compulsory specifications nor to type testing. The manufacturer declares conformity with the EC directive. For the standard designs of our fans, the following ignition sources are essentially to be considered: Hot surfaces, e.g. due to heat of friction or seizure of a bearing or due to blockage of an impeller Rubbing-, grinding- or beating sparks, e. g. as a result of contact of the impeller with stationary components Sparks resulting from discharge of electrostatically loaded, non-conducting omponents, e. g. of plasticpanels, surfaces with strong layer thickness. Preconditions for operating: In the proximity of the, the temperature limits -2 C and +4 C must not be exceeded. The temperature limits of -2 C und +6 C for the medium must not be exceeded. If the temperature of the medium should exceed +6 C on the pressure side, then the fan must be switched off! The fans may only be employed with a horizontal shaft. The fans are to be protected against the falling-in or sucking-in of foreign objects. Protection guards must be ordered separately as an accessories. On the machine plate the max. permitted fan speed is indicated. Fans for operation in ex-hazardous areas are marked as such on the machine plate and they are accompanied by an EU conformity declaration and with operation and maintenance instructions The operation and maintenance instructions have strictly to be observed. 329
5 REM 1-2 Direct driven centrifugal fans / REM / db 72 REM D-7 REM X-7-2G 4 V 5 Hz [A1/A2] 8 76 db REM D V 6 Hz 76 [A3] Density of media 1.2 kg/m³ Measured in installation B according to ISO
6 REM 1-2 Direct driven centrifugal fans / REM / power Poles frequency speed max. REM..- kw V Hz A 1/min C kg 2-2D-7 [A1] /4 5 D/Y 1.73/ /12/14/16 power Poles frequency speed max. REM..-Ex II 2G c IIB T3 kw V Hz A 1/min C kg 2-2X-7-2G [A2] /4 5 D/Y 1.61/ /12/14/16 power Poles frequency speed max. REM..-6 Hz kw V Hz A 1/min C kg 2-2D-7-6 [A3] Y /12/14/16 protection can take place through protection units with bi-metallic releases (EUM 33) or via a thermistor (NTC) temperature sensor in connection with a thermistor (NTC)-release device (EUM 3). See chapter "Accessories". The direction of rotation is determined looking from the drive side. - Anti-clockwise rotation, symbol LG. - Clockwise rotation, symbol RD. Dimensions in mm, subject to change. REM 11-2 REM k2 Ø7 188 k S L L M S M M LG RD REM 18-2 REM Ø Ø7. 84+k Ø25 Ø235 Ø M ZSG ZKE 11 ZKF 11 Ø1 312 ZKE 16 ZKF LG LG 9 LG 27 RD RD 9 RD
7 REM Direct driven centrifugal fans / REM / db REM D-7 REM X-7-2G 4 V 5 Hz [B1/B2] db 79 [B3] REM D V 6 Hz Density of media 1.2 kg/m³ Measured in installation B according to ISO
8 REM Direct driven centrifugal fans / REM / power Poles frequency speed max. REM..- kw V Hz A 1/min C kg 225-2D-7 [B1] /4 5 D/Y 1.73/ /13/16/18 power Poles frequency speed max. REM..-Ex II 2G c IIB T3 kw V Hz A 1/min C kg 225-2X-7-2G [B2] /4 5 D/Y 1.61/ /13/16/18 power Poles frequency speed max. REM..-6 Hz kw V Hz A 1/min C kg 225-2D-7-6 [B3] Y /13/16/18 protection can take place through protection units with bi-metallic releases (EUM 33) or via a thermistor (NTC) temperature sensor in connection with a thermistor (NTC)-release device (EUM 3). See chapter "Accessories". The direction of rotation is determined looking from the drive side. - Anti-clockwise rotation, symbol LG. - Clockwise rotation, symbol RD. Dimensions in mm, subject to change. REM REM k2 Ø1 21 k S L L M S M M LG RD REM REM Ø Ø7. 89+k Ø229 Ø259 Ø M ZSG ZKE 11 ZKF 11 Ø1 376 ZKE 16 ZKF LG LG 9 LG 27 RD RD 9 RD
9 REM 1-25 Direct driven centrifugal fans / REM / db REM D-8 REM X-8-2G 4 V 5 Hz 78 [C1/C2] db 83 REM D V 6 Hz 85 [C3] Density of media 1.2 kg/m³ Measured in installation B according to ISO
10 REM 1-25 Direct driven centrifugal fans / REM / power Poles frequency speed max. REM..- kw V Hz A 1/min C kg 25-2D-8 [C1] /4 5 D/Y 2.35/ /17/21/23 power Poles frequency speed max. REM..-Ex II 2G c IIB T3 kw V Hz A 1/min C kg 25-2X-8-2G [C2] /4 5 D/Y 2.42/ /17/21/23 power Poles frequency speed max. REM..-6 Hz kw V Hz A 1/min C kg 25-2D-1-6 [C3] Y /2/24/26 protection can take place through protection units with bi-metallic releases (EUM 33) or via a thermistor (NTC) temperature sensor in connection with a thermistor (NTC)-release device (EUM 3). See chapter "Accessories". The direction of rotation is determined looking from the drive side. - Anti-clockwise rotation, symbol LG. - Clockwise rotation, symbol RD. Dimensions in mm, subject to change. REM REM k2 Ø1 231 k S L L M S M M LG RD REM REM Ø Ø7. 98+k2 1 1 Ø256 Ø286 Ø M ZSG ZKE 11 ZKF 11 Ø1 376 ZKE 16 ZKF LG LG 9 LG 27 RD RD 9 RD
11 REM 1-28 Direct driven centrifugal fans / REM / db REM D-11 REM X-11-2G 4 V 5 Hz db REM D V 6 Hz [D1/D2] [D3] Density of media 1.2 kg/m³ Measured in installation B according to ISO
12 REM 1-28 Direct driven centrifugal fans / REM / power Poles frequency speed max. REM..- kw V Hz A 1/min C kg 28-2D-11 [D1] /4 5 D/Y 4.25/ /21/26/29 power Poles frequency speed max. REM..-Ex II 2G c IIB T3 kw V Hz A 1/min C kg 28-2X-11-2G [D2] /4 5 D/Y 4.33/ /21/26/29 power Poles frequency speed max. REM..-6 Hz kw V Hz A 1/min C kg 28-2D-11-6 [D3] Y /21/26/29 protection can take place through protection units with bi-metallic releases (EUM 33) or via a thermistor (NTC) temperature sensor in connection with a thermistor (NTC)-release device (EUM 3). See chapter "Accessories". The direction of rotation is determined looking from the drive side. - Anti-clockwise rotation, symbol LG. - Clockwise rotation, symbol RD. Dimensions in mm, subject to change. REM REM k2 Ø1 258 k S L L M S M M LG RD REM REM Ø Ø k Ø288 Ø322 Ø M ZSG ZKE 11 ZKF 11 Ø1 446 ZKE 16 ZKF LG LG 9 LG 27 RD RD 9 RD
13 REM Direct driven centrifugal fans / REM / db REM D-13 REM X-14-2G 4 V 5 Hz 25 REM D V 6 Hz [E1/E3] db 91 [E5] db REM D-7 REM X-7-2G 4 V 5 Hz 6 REM D V 6 Hz [E2/E4] db 72 [E6] Density of media 1.2 kg/m³ Measured in installation B according to ISO
14 REM Direct driven centrifugal fans / REM / power Poles frequency speed max. REM..- kw V Hz A 1/min C kg 315-2D-13 [E1] S 23/4 5 D/Y 5.7/ /28/33/ D-7 [E2] /4 5 D/Y 1.32/ /22/26/29 power Poles frequency speed max. REM..-Ex II 2G c IIB T3 kw V Hz A 1/min C kg 315-2X-14-2G [E3] L 23/4 5 D/Y 6.85/ /31/36/ X-7-2G [E4] /4 5 D/Y 1.39/ /22/26/29 power Poles frequency speed max. REM..-6 Hz kw V Hz A 1/min C kg 315-2D-14-6 [E5] L 46 6 Y /31/36/ D-7-6 [E6] Y /22/14/29 protection can take place through protection units with bi-metallic releases (EUM 33) or via a thermistor (NTC) temperature sensor in connection with a thermistor (NTC)-release device (EUM 3). See chapter "Accessories". The direction of rotation is determined looking from the drive side. - Anti-clockwise rotation, symbol LG. - Clockwise rotation, symbol RD. Dimensions in mm, subject to change. REM REM k2 Ø1 29 k S L L M S M M LG RD REM REM Ø Ø k Ø322 Ø356 Ø M ZSG ZKE 11 ZKF 11 Ø1 446 ZKE 16 ZKF LG LG 9 LG 27 RD RD 9 RD
15 REM Direct driven centrifugal fans / REM / db REM D-16 REM X-19-2G 4 V 5 Hz 89 [F1/F3] db 94 REM D V 6 Hz [F5] db 71 REM D-8 REM X-8-2G 4 V 5 Hz [F2/F4] db REM D V 6 Hz 76 [F6] Density of media 1.2 kg/m³ Measured in installation B according to ISO
16 REM Direct driven centrifugal fans / REM / power Poles frequency speed max. REM..- kw V Hz A 1/min C kg 355-2D-16 [F1] L 23/4 5 D/Y 1.6/ /39/43/ D-8 [F2] /4 5 D/Y 1.78/ /28/32/37 power Poles frequency speed max. REM..-Ex II 2G c IIB T3 kw V Hz A 1/min C kg 355-2X-19-2G [F3] M 23/4 5 D/Y 11.6/ /58/62/ X-8-2G [F4] /4 5 D/Y 1.91/ /28/32/37 power Poles frequency speed max. REM..-6 Hz kw V Hz A 1/min C kg 355-2D-19-6 [F5] M 46 6 D /44/48/ D-1-6 [F6] Y /31/16/4 protection can take place through protection units with bi-metallic releases (EUM 33) or via a thermistor (NTC) temperature sensor in connection with a thermistor (NTC)-release device (EUM 3). See chapter "Accessories". The direction of rotation is determined looking from the drive side. - Anti-clockwise rotation, symbol LG. - Clockwise rotation, symbol RD. Dimensions in mm, subject to change. REM REM k2 Ø1 325 k S L L M S M M LG RD REM REM Ø Ø k Ø361 Ø395 Ø M ZSG ZKE 11 ZKF 11 Ø1 446 ZKE 16 ZKF LG LG 9 LG 27 RD RD 9 RD
17 REM 1-4 Direct driven centrifugal fans / REM / db 92 REM D-21 REM X-22-2G 4 V 5 Hz [G1/G3] db 97 REM D V 6 Hz [G5] db 73 REM D-1 REM X-11-2G 4 V 5 Hz [G2/G4] db 78 REM D V 6 Hz [G6] Density of media 1.2 kg/m³ Measured in installation B according to ISO
18 REM 1-4 Direct driven centrifugal fans / REM / power Poles frequency speed max. REM..- kw V Hz A 1/min C kg 4-2D-21 [G1] S 4/69 5 D/Y 1.6/ /77/ / 4-4D-1 [G2] /4 5 D/Y 2.5/ /32/6/63 power Poles frequency speed max. REM..-Ex II 2G c IIB T3 kw V Hz A 1/min C kg 4-2X-22-2G [G3] S 4/69 5 D/Y 1.7/ /84/ / 4-4X-11-2G [G4] /4 5 D/Y 3.55/ /32/6/64 power Poles frequency speed max. REM..-6 Hz kw V Hz A 1/min C kg 4-2D-22-6 [G5] S 46 6 D /78/ / 4-4D-13-6 [G6] S 46 6 Y /36/64/67 For "REM..-4-2D-21", "..-2X-22-2G" and "..-2D-22-6" only model "13-" available! protection can take place through protection units with bi-metallic releases (EUM 33) or via a thermistor (NTC) temperature sensor in connection with a thermistor (NTC)-release device (EUM 3). See chapter "Accessories". The direction of rotation is determined looking from the drive side. - Anti-clockwise rotation, symbol LG. - Clockwise rotation, symbol RD. Dimensions in mm, subject to change. REM 11-4 REM k2 Ø1 369 k S L L M S M M LG RD REM 18-4 REM Ød Ø k2 Ø M8 Ø44 Ø438 Ø ZSG ZKE 11 ZKF 11 ZBG ZKE 16 ZKF 16 LG LG 9 LG 18 LG 27 RD RD 9 RD 18 RD
19 REM 1-45 Direct driven centrifugal fans / REM / db 76 REM D-13 REM X-13-2G 4 V 5 Hz [H1/H2] db 81 REM D V 6 Hz 83 [H3] Density of media 1.2 kg/m³ Measured in installation B according to ISO
20 REM 1-45 Direct driven centrifugal fans / REM / power Poles frequency speed max. REM..- kw V Hz A 1/min C kg 45-4D-13 [H1] S 23/4 5 D/Y 4.5/ /43/63/68 power Poles frequency speed max. REM..-Ex II 2G c IIB T3 kw V Hz A 1/min C kg 45-4X-13-2G [H2] S 23/4 5 D/Y 4.33/ /47/76/81 power Poles frequency speed max. REM..-6 Hz kw V Hz A 1/min C kg 45-4D-14-6 [H3] L 46 6 Y /46/26/71 protection can take place through protection units with bi-metallic releases (EUM 33) or via a thermistor (NTC) temperature sensor in connection with a thermistor (NTC)-release device (EUM 3). See chapter "Accessories". The direction of rotation is determined looking from the drive side. - Anti-clockwise rotation, symbol LG. - Clockwise rotation, symbol RD. Dimensions in mm, subject to change. REM REM k2 Ø k S L L M S M 374 REM REM k2 Ø Ø M M8 6 Ø Ø453 Ø487 Ø LG RD 713 ZSG ZKE 11 ZKF 11 ZBG ZKE 16 ZKF 16 LG LG 9 LG 18 LG 27 RD RD 9 RD 18 RD
21 REM 1-5 Direct driven centrifugal fans / REM / db 79 REM D-16 REM X-16-2G 4 V 5 Hz [I1/I3] db 83 REM D V 6 Hz [I4] db 68 REM D-11 4 V 5 Hz 7 [I2] db 72 REM D V 6 Hz [I5] Density of media 1.2 kg/m³ Measured in installation B according to ISO
22 REM 1-5 Direct driven centrifugal fans / REM / power Poles frequency speed max. REM..- kw V Hz A 1/min C kg 5-4D-16 [I1] L 23/4 5 D/Y 8.2/ /62/94/1 5-6D-11 [I2] /4 5 D/Y 2.8/ /52/84/9 power Poles frequency speed max. REM..-Ex II 2G c IIB T3 kw V Hz A 1/min C kg 5-4X-16-2G [I3] L 23/4 5 D/Y 7.8/ /74/16/112 power Poles frequency speed max. REM..-6 Hz kw V Hz A 1/min C kg 5-4D-17-6 [I4] L 46 6 Y /66/98/14 5-6D-13-6 [I5] S 46 6 Y /55/87/93 protection can take place through protection units with bi-metallic releases (EUM 33) or via a thermistor (NTC) temperature sensor in connection with a thermistor (NTC)-release device (EUM 3). See chapter "Accessories". The direction of rotation is determined looking from the drive side. - Anti-clockwise rotation, symbol LG. - Clockwise rotation, symbol RD. Dimensions in mm, subject to change. REM 11-5 REM k2 Ø k S L L M S M 374 REM 18-5 REM k2 Ø Ø M M8 6 Ø Ø57 Ø541 Ø LG RD 783 ZSG ZKE 11 ZKF 11 ZBG ZKE 16 ZKF 16 LG LG 9 LG 18 LG 27 RD RD 9 RD 18 RD
23 REM 1-56 Direct driven centrifugal fans / REM / db REM D-19 REM X-19-2G 4 V 5 Hz 83 [J1/J3] db 88 REM D V 6 Hz [J4] db 72 REM D-14 4 V 5 Hz [J2] db REM D V 6 Hz [J5] Density of media 1.2 kg/m³ Measured in installation B according to ISO 581 3
24 REM 1-56 Direct driven centrifugal fans / REM / power Poles frequency speed max. REM..- kw V Hz A 1/min C kg 56-4D-19 [J1] M 4/69 5 D/Y 8.2/ /94/133/ D-14 [J2] L 23/4 5 D/Y 4.9/ /72/111/118 power Poles frequency speed max. REM..-Ex II 2G c IIB T3 kw V Hz A 1/min C kg 56-4X-19-2G [J3] M 23/4 5 D/Y 13./ /98/137/144 power Poles frequency speed max. REM..-6 Hz kw V Hz A 1/min C kg 56-4D-21-6 [J4] S 46 6 D /15/144/ D L 46 6 Y /75/114/121 protection can take place through protection units with bi-metallic releases (EUM 33) or via a thermistor (NTC) temperature sensor in connection with a thermistor (NTC)-release device (EUM 3). See chapter "Accessories". The direction of rotation is determined looking from the drive side. - Anti-clockwise rotation, symbol LG. - Clockwise rotation, symbol RD. Dimensions in mm, subject to change. REM REM k2 Ø k S L L M S M 374 REM REM k2 Ø Ø M M1 8 Ø Ø569 Ø65 Ø LG RD 884 ZSG ZKE 11 ZKF 11 ZBG ZKE 16 ZKF 16 LG LG 9 LG 18 LG 27 RD RD 9 RD 18 RD 27 31
25 REM 1-63 Direct driven centrifugal fans / REM / db REM D-23 REM X-23-2G 4 V 5 Hz 86 [K1/K3] db 76 [K2] REM D-19 4 V 5 Hz db 8 REM D V 6 Hz 82 [K4] Density of media 1.2 kg/m³ Measured in installation B according to ISO
26 REM 1-63 Direct driven centrifugal fans / REM / speed max. frequenction Connec- power Poles REM..- kw V Hz A 1/min C kg 63-4D-23 [K1] M 4/69 5 D/Y 15.4/ /13/ / 63-6D M 23/4 5 D/Y 9.2/ /13/151/159 speed max. frequenction Connec- power Poles REM..-Ex II 2G c IIB T3 kw V Hz A 1/min C kg 63-4X-23-2G [K3] M 4/69 5 D/Y 14./ /135/ / speed max. frequenction Connec- power Poles REM..-6 Hz kw V Hz A 1/min C kg 63-6D-21-6 [K4] S 46 6 Y /112/166/168 For "REM D-23" and "..-4X-23-2G" only model "13-" available! protection can take place through protection units with bi-metallic releases (EUM 33) or via a thermistor (NTC) temperature sensor in connection with a thermistor (NTC)-release device (EUM 3). See chapter "Accessories". The direction of rotation is determined looking from the drive side. - Anti-clockwise rotation, symbol LG. - Clockwise rotation, symbol RD. Dimensions in mm, subject to change. REM REM k2 Ø k S L L M S M 374 REM REM k2 Ø Ø M M1 8 Ø Ø638 Ø674 Ø a3 b LG RD 984 ZSG ZKE 11 ZKF 11 ZBG ZKE 16 ZKF 16 LG LG 9 LG 18 LG 27 RD RD 9 RD 18 RD 27 33
Powerful centrifugal fans for universal use: The product ranges TEM and REM
Powerful centrifugal fans for universal use: The product ranges TEM and REM The fan ranges TEM and REM offered by Nicotra Gebhardt do present a large fan programme of single inlet centrifugal fans which
More informationCentrifugal Fans RZR belt driven. Issue 2.5 EN August 2013
Centrifugal Fans RZR belt driven Issue 2.5 EN August 2013 1 AMCA Nicotra Gebhardt S.p.A. (Italy) certifies that ADH-E fans of the E0, E2, E4, E6 and E7 versions, from sizes 01 to 05, RDH-E fans of the
More informationCentrifugal Fans ADH belt driven. Issue 2.5 EN August 2013
Centrifugal Fans ADH belt driven Issue 2.5 EN August 2013 1 AMCA Nicotra Gebhardt S.p.A. (Italy) certifies that ADH-E fans of the E0, E2, E4, E6 and E7 versions, from sizes 0160 to 0560, RDH-E fans of
More informationVORTICENT C E RANGE Centrifugal fans
NEW VORTICENT C E RANGE Centrifugal fans Suitable for domestic, commercial and industrial applications: kitchens, bathrooms, offices, laboratories, factories, shops, laundromats, models, restaurants, bars,
More informationRLM EVO High Performance - Plug Fans Impeller with true airfoil blades
RLM EVO High Performance - Plug Fans Impeller ith true airfoil blades Issue 1 1 RLM EVO Ready for the next generation Overall static RLM EVO 211 213 215 ErP-Guideline 9/125/EG We have accelerated impeller
More informationhore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig CENTRIFUGAL FANS HV VAC &
hore nd Offsh arine an ms for Ma geration System & Refrig HV VAC & PRODUCT CATALOGUE CENTRIFUGAL FANS ! "# $ % & " ' (! ) * +,+( -../01..2 PRODUCT CATALOGUE 73-16 CENTRIFUGAL FANS CONTENT PAGE 1. CENTRIFUGAL
More informationSpecifications. Applications Ventilation of safety cabinets (STORM 10), scrubbers, fume capture arms, filter housing, etc. (STORM 12, 14, 16).
Specifications Applications Ventilation of safety cabinets (STORM 10), scrubbers, fume capture arms, filter housing, etc. (STORM 12, 14, 16). Housings: PP* Single block strong high density UV treated and
More informationCentrifugal performance characteristics with axial flow pattern: RADAX VAR
High pressure in-line mixed-flow fans RADAX VAR Centrifugal performance characteristics with axial flow pattern: RADAX VAR COMPACT PRESSURE-RESISTANT UNIVERSAL In their compact casing, the RADAX VAR impellers
More informationSmall centrifugal fans made of plastic
Small centrifugal fans made of plastic durable application-optimised wide range of variants 2 Small centrifugal fans made of plastic Index Small centrifugal fans made of plastic HF R 75-16 D and HF R 110-18
More informationCentrifugal fan with highly efficient EC drive motor
Centrifugal fan with highly efficient EC drive motor simple and safe application and installation 2 Why HLU? 90 years of experience in the plastics processing market More than 10.000 m² production in Germany
More informationAxial Flow Fans. Issue 6.
Issue 6 1 Content 4 5 6 13 14 17 18 21 22 23 24 43 44 45 46 47 Technical data Curves Dimensions Specifications Samples Accessories Description Notes 2 High Performance - AQA 61-315/-63 Square wall mounting
More informationCMRT Series BACKWARD CURVED CENTRIFUGAL FANS. Backward curved centrifugal fans CMRT 80 C
BACKWARD CURVED CENTRIFUGAL FANS CMRT Series 80 C Continuous operation Range of single inlet direct drive centrifugal fans designed for continuous extraction of air stream up to 80ºC. Casings are manufactured
More informationCENTRIFLOW 3D WITH AC MOTOR >> Technical catalogue
CENTRIFLOW 3D plug fan WITH AC MOTOR >> Technical catalogue air comfort Centriflow 3D 2 GMEB CentriFlow 3D - Technical Catalogue Contents GENERAL Description and survey chart Application... 3 General Survey
More informationFEATURES & BENEFITS UPON REQUEST
ErP 27 IDUSTRIAL CETRIFUGAL FAS WITH VERY HIGH PRESSURE APPLICATIO High pressure industrial centrifugal fans with backward curved impeller, suitable for exhausting clean or slightly dusty air. They can
More informationCSXRT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJSXR: Ventilation units with a backward-curved impeller
CSXR CSXRT CJSXR CSXR: Belt-driven single inlet centrifugal fans with shaft outlet and backward-curved impeller CSXRT: Belt-driven single inlet centrifugal fans fitted with electric motors, a set of pulleys
More informationAXIAL FANS Catalogue CN0050C01 May 2008
ADTA AXIAL FANS Catalogue CN0050C01 May 2008 ADTA AXIAL FANS Catalogue CN0050C01 May 2008 Construction Specifications Impellers: Breezax aerfoil blades are available in four types of material: Glass Reinforced
More informationCENTRIFUGAL DIRECT DRIVE FANS CMT-CMB
CENTRIFUGAL DIRECT DRIVE FANS CMT-CMB Applications The CMT-CMB range of fans are suitable for many general and OEM ventilation applications where the extract of nonhazardous heated air is required. The
More informationGmbH Lufttechnik Dresden USER INFORMATION ROOF FANS SERIES VRV. vertical outlet. Issue 07/02
GmbH Lufttechnik Dresden USER INFORMATION ROOF FANS SERIES VRV vertical outlet Issue 07/02 Roof fans made of plastic materials Series VRV with vertical outlet Usable in ventilation engineering of all branches
More informationCentrifugal Fans belt driven. TD_CFB-RDY_EN Issue 1.1 EN July 2013
Centrifugal Fans belt driven TD_CFB-RDY_EN Issue 1.1 EN July 2013 Y D R 1 AMCA Nicotra Gebhardt S.p.A. certifi es that the fan shon herein is licensed to bear the AMCA Seal. The ratings shon are based
More informationCNA-CNB CNA-CNB CENTRIFUGAL FANS STANDARD TEMPERATURES AND EX
NA-NB NA-NB ENTRIFUGAL FANS STANDARD TEMPERATURES AND EX PRODUT FATS PRODUT The centrifugal fans type NA and NB are robust and versatile fans of the single-inlet type with backward-curved blades. APPLIATION
More informationAAVC. Accessories HIGH PRESSURE FANS HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES:
AAVC HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES: Accessories Fan made of Fe360 sheet. The fan paint finish is based on a Qualicoat polyester powder coating stoved at 200ºC, with an average
More informationROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE
ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE Roofmaster STEC non-insulated version - Technical Catalogue 3 CONTENTS GENERAL DESCRIPTION Application/specification...4 Features...4
More informationKAT. DOUBLE INLET CENTRIFUGAL FAN with Forward Wheels
KAT DOUBLE INLET ENTRIFUGAL FAN with Forward Wheels KAT Series DOUBLE INLET ENTRIFUGAL FAN with Forward Wheels Kruger Ventilation Industries certifies that the KAT series : version S and - model 9-7 to
More informationCONTINUO. Radial centrifugal impeller. Radial centrifugal impellers dynamically balanced, according to ISO 1940 standard,
RADIAL CENTRIFUGAL FANS CBT-N Series CONTINUO Range of single inlet direct driven centrifugal fans designed for the continuous extraction of air stream up to 120ºC(1). The casings are manufactured from
More informationV.I.R.T.U.O. Ventilation boxes. Comfort ventilation boxes
Comfort ventilation Very wide flow rate range : 0.11 to 9.72 m 3 /s Standard version with lacquered finish casing APPLICATION ventilation are designed for the ventilation of tertiary or industrial buildings,
More informationROOFMASTER STEF-ATEX ROOF FAN
Air Comfort Air movement Roof fans ROOFMASTER STEF-ATEX ROOF FAN» Technical CATALOGuE 2 STEF-ATEX Roofmaster - Technical Catalogue Contents General description Application/specification... 3 Features...
More informationCENTRIFLOW 3D WITH AC MOTOR >> Technical catalouge
CENTRIFLOW 3D plug fan WITH AC MOTOR >> Technical catalouge air comfort Centriflow 3D 2 GMEB CentriFlow 3D - Technical Catalouge Contents GENERAL Description and survey chart Application... 3 General Survey
More informationCMB / CMT Series CENTRIFUGAL SINGLE INLET FANS. Centrifugal direct drive fans CMB/CMT 80 C. Impeller dynamically balanced
CENTRIFUGAL SINGLE INLET FANS CMB / CMT Series 80 C CONTINUOUS operation Range of centrifugal single inlet fans suitable for continuous extraction of airstreams temperature up to 80ºC (Series 1) or 150ºC
More informationCompany name: Created by: Phone:
Position Qty. Description 1 TP 8-/2 A-F-A-BQQE Date: 29/1/18 Product No.: 9618724 Single-stage, close-coupled, volute pump with in-line suction and discharge ports of identical diameter. The pump is of
More informationCentrifugal medium-pressure fans fitted with multi-blade
CMP/ATEX CMP/ATEX impeller Centrifugal medium-pressure fans fitted with multi-blade with ATEX certification Centrifugal single-inlet, medium-pressure fans with casing and sheet steel impeller to work in
More informationCAS 460 2T 7.5. Impeller size motor poles 2=3500 r/min. 60 Hz. Installed power
CAS CAS: High pressure, single inlet centrifugal fans with sheet steel casing and impeller : High pressure, single inlet centrifugal fans with sheet steel casing and impeller, fitted with acoustic attenuators
More informationCompany name: Created by: Phone:
Position Qty. Description 1 TP -42/2 A-F-A-BQQE Date: 26/1/218 Product No.: 9874287 Single-stage, close-coupled, volute pump with in-line suction and discharge ports of identical diameter. The pump is
More informationCYLINDRICAL CASED AXIAL FLOW FANS TGT Series - ADJUSTABLE PITCH FANS
- ADJUSTABLE PITCH FANS Range of adjustable pitch aerofoil blade, cased axial flow fans. Casings formed from rolled sheet steel with a corrosion resistant hot dip galvanised finish. All models incorporate
More informationCBM Small Series LOW PRESSURE CENTRIFUGAL FANS. CBM Small. Low pressure centrifugal fans. Impeller dynamically balanced.
LOW PRESSURE CENTRIFUGAL FANS CBM Small Series Range of single and double inlet direct driven low pressure centrifugal fans manufactured from galvanised sheet steel and protected against corrosion by a
More informationTCDH F400-TCDV F400. Smoke extract - Fire protection SMOKE EXTRACT FANS CENTRIFUGAL BACKWARD ROOF FANS F Application. Range.
N OU VE A U Approved F400 10 (400 C 10 mn) CE marked Special range for speed variation VAR Easy installation and maintenance Low sound level Electrical accessories and relay box mounted wired New vertical
More informationCGT Series Adjustable Pitch Fans
AXIAL FLOW CABINET FAN CGT Series Adjustable Pitch Fans New Ø 400-450-500 Range of adjustable pitch aerofoil blade, axial flow cabinet fans.fan casing manufactured from heavy gauge galvanised sheet steel
More informationSabre Plate Mounted Sickle Fans (VSP)
Sabre Plate Mounted Sickle Fans (VSP) Swept impeller with Aerofoil blades, winglets and serrated trailing edge for optimum performance One shot die cast impeller, dynamically balanced for smoother operation
More informationCBM Series LOW PRESSURE CENTRIFUGAL FANS CBM. Low pressure centrifugal fans. Impeller dynamically balanced. Anti-vibration mounts
LOW PRESSURE CENTRIFUGAL FANS Series Range of double inlet direct driven low pressure centrifugal fans manufactured from galvanised sheet steel. All the models are fitted with forward curved centrifugal
More informationMTB /183 A-F-A-BQQV 400D-2 11kW
GRUNDFOS DATA BOOKLET MTB 65-2/13 A-F-A-BQQV D-2 11kW Grundfos Pump 965751 Thank you for your interest in our products Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/mtb/965751/mtb-65-2-13-a-f-a-bqqv.html
More informationCHMT Series, F Rated Fans
CNTRIFUGAL SINGL INLT FANS CT Series, F400 120 Rated Fans Officially approved to N12101-3 standard (certificate number 0370-CPD-0348) Range of single inlet direct drive centrifugal fans designed for smoke
More informationCRN45-10 A-F-G-V-HQQV 3x400/ HZ
GRUNDFOS DATA BOOKLET CRN45-1 A-F-G-V-HQQV 3x4/69 5 HZ Grundfos Pump 9612316 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn45/9612316/crn-45-1-a-f-g-v-hqqv.html
More informationCategory 1 (zone 0) covers areas, where there is a permanent or long lasting occurrence
Explosion proof fans General Systemair explosion proof fans have been developed to be used in effective supply and exhaust air systems allocated to category 2 (zone 1) and category 3 (zone 2) in explosion
More informationRoof Extract Fans DV Ventilation Hoods DLH Smoke Extract Fans ER
Roof Extract Fans DV Ventilation Hoods DLH Smoke Extract Fans ER Roof Extract Fans Ventilation Hoods Smoke Extract Fans DV DLH ER Summary... Seite Roof Extract Fans DV Product review... Summary data sheet...
More informationUnobox units with backward curved centrifugal impellers
Unobox Fans Unobox units with backward curved centrifugal impellers Type Code UNO 67-450 -4 E W Unobox Box size 50=500mm ; 67=670mm 80=800mm ; 102=1020mm Impeller diameter Number of poles D - Three Phase
More informationCGT Series Adjustable Pitch Fans
AXIAL FLOW CABINET FAN CGT Series Adjustable Pitch Fans New Ø 400-450-500 Range of adjustable pitch aerofoil blade, axial flow cabinet fans.fan casing manufactured from heavy gauge galvanised sheet steel
More informationRLM EVO High Performance - Plug Fans Impeller with true airfoil blades. Issue 1 June 2011
RLM EVO High Performance - Plug Fans Impeller with true airfoil blades Issue 1 June 2011 1 RLM EVO Ready for the next generation Overall static efficiency RLM EVO 2011 2013 2015 ErP-Guideline 2009/125/EG
More informationCRN45-5 A-F-G-V-HQQV 3x400/ HZ
GRUNDFOS DATA BOOKLET CRN45-5 A-F-G-V-HQQV 3x4/69 5 HZ Grundfos Pump 9612315 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn45/9612315/crn-45-5-a-f-g-v-hqqv.html
More informationSection 4. Axial Fans - Section 4
Axial Flow Fans Section 4 Fläkt Woods offers a wide range of axial flow fans for general air movement and special applications such as emergency high temperature smoke extract and pressurisation. ATEX
More informationA Smarter Breed. of Centrifugal Fans
A Smarter Breed of Centrifugal Fans The new range of Blue Rhino backward-curved centrifugal fans can save on-site installation and commissioning time, reduce service costs and provide greater reliability.
More informationCRN A-F-G-V-HQQV 30kW 3x400D 50Hz
GRUNDFOS DATA BOOKLET CRN15-3-2 A-F-G-V-HQQV 3kW 3x4D 5Hz Grundfos Pump 95922425 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn15/95922425/crn-15-3-2-a-f-g-v-hqqv.html
More informationFAN & BLOWER CENTRIFUGAL FANS
FAN & BLOWR CNTRIFUGAL FANS INTRODUCTION GNRAL PRODUCT RANG FANS BY FANTCH - INTRACTIV PRODUCT SUIT SLCTION PROGRAM PRFORMANC CONSTRUCTION The Fan & Blower range of centrifugal fans is marketed to the
More informationFor ATEX zone 1/1, 22/22 and 21/21. Work area: Max. pressure: 5,800Pa Max. air volume: 32,500m³/h
For ATEX zone 1/1, 22/22 and 21/21 Centrifugal fan with closed fan wheel that is used at source extraction from air pollulant or chip making work processes. The transported air may not contain adhestive
More informationPneumatic Axial Fan Type Tech. Doc. No. 802
Pneumatic Axial Fan Type Tech. Doc. No. 802 Illustration can differ from the original Operation and Maintenance Manual Compiled: 06.08.13 815340300_en_Version_02 Page 1 of 11 ATTENTION!!! This pneumatic
More informationDynamically-balanced impellers with extremely robust cores CMP T 5.5
Medium pressure, single inlet centrifugal fans with sheet steel casing and impeller Fan: Sheet steel casing. Forward-curved impeller made of galvanised sheet steel. 38-2M model casing in cast aluminium.
More informationCRN120-7 A-F-G-V-HBQV 75kW 3x400D 50Hz
GRUNDFOS DATA BOOKLET CRN12-7 A-F-G-V-HBQV 75kW 3x4D 5Hz Grundfos Pump 9592225 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn12/9592225/crn-12-7-a-f-g-v-hbqv.html
More informationCR A-F-A-V-HBQV 3x400/ HZ
GRUNDFOS DATA BOOKLET CR12-6-1 A-F-A-V-HBQV 3x4/69 5 HZ Grundfos Pump 95922172 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/95922172/cr-12-6-1-a-f-a-v-hbqv.html
More informationCM5-11 A-R-G-E-AQQE F-A-A-N
GRUNDFOS DATA BOOKLET CM5-11 A-R-G-E-AQQE F-A-A-N Grundfos Pump 96935476 Thank you for your interest in our products Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/cmbasis/96935476/cm5-11-a-r-g-e-aqqe.html
More informationCR45-10 A-F-A-E-HQQE 3x400/ HZ
GRUNDFOS DATA BOOKLET CR45-1 A-F-A-E-HQQE 3x4/69 5 HZ Grundfos Pump 96122815 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/96122815/cr-45-1-a-f-a-e-hqqe.html
More informationCRN A-F-G-V-HQQV 3x400/ HZ
GRUNDFOS DATA BOOKLET CRN64-7-2 A-F-G-V-HQQV 3x4/69 5 HZ Grundfos Pump 96123813 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn64/96123813/crn-64-7-2-a-f-g-v-hqqv.html
More informationCRN A-F-G-V-HQQV 3x400/ HZ
GRUNDFOS DATA BOOKLET CRN15-2-1 A-F-G-V-HQQV 3x4/69 5 HZ Grundfos Pump 95922424 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn15/95922424/crn-15-2-1-a-f-g-v-hqqv.html
More informationCR A-F-A-V-HQQV 3x400/ HZ
GRUNDFOS DATA BOOKLET CR64-7-1 A-F-A-V-HQQV 3x4/69 5 HZ Grundfos Pump 96123566 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/96123566/cr-64-7-1-a-f-a-v-hqqv.html
More informationF a n t y p e s J K K - J K K
F a n t y p e s J K - 3 K - J K - 7 5 K Section: 2 Page: 1/6 Revised: 1..25 The indirect drive centrifugal fan types JK-3K - JK-75K are designed for material handling. M N Equipped with self-cleaning impellers
More informationAATVP. Accessories HIGH PRESSURE FANS HIGH PRESSURE WITH BACKWARD IMPELLER AND BELT TRASMISSION MANUFACTURING FEATURES:
AATVP HIGH PRESSURE WITH BACKWARD IMPELLER AND BELT TRASMISSION MANUFACTURING FEATURES: Accessories Fan made of Fe36 sheet. The fan paint finish is based on a Qualicoat polyester powder coating stoved
More informationTSAT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJTSA: Ventilation units with a forward-curved impeller.
TSA TSAT CJTSA TSA: Single inlet, belt-driven centrifugal fans with shaft outlet and forward-curved impeller. TSAT: Single inlet, belt-driven centrifugal fans fitted with electric motors, a set of pulleys
More informationVALIADIS S.A. HELLENIC MOTORS
Explosion proof motors MAK 56-250 (MAKe 63-250) series Groups IIB and IIC Ex db / Ex db e (EPL) executions Gb or Ex tb IIIC (EPL) Db II 2 G, II 2D, 2GD SAFETY INSTRUCTIONS Safety Instructions MAK and MAKe
More informationRLM EVO High Performance Plug Fans Impeller with true airfoil blades. Issue 1.4 EN June 2012
RLM EVO High Performance Plug Fans Impeller with true airfoil blades Issue 1.4 EN June 2012 1 RLM EVO Ready for the next generation We have accelerated impeller technology with the RLM Evo series, the
More informationROOFMASTER STEF-HT ROOF FAN
fire safety Air movement Roof Fans ROOFMASTER STEF-HT ROOF FAN» Technical CATALOGuE Contents ROOFMASTER STEF-HT...3 Performance Data...4 Performance Table...5 General description...6 Fan Chart-explanation
More informationCR A-F-A-E-HQQE 3x400/ HZ
GRUNDFOS DATA BOOKLET CR32-1-2 A-F-A-E-HQQE 3x4/69 5 HZ Grundfos Pump 9612224 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/9612224/cr-32-1-2-a-f-a-e-hqqe.html
More informationCR45-5 A-F-A-E-HQQE 3x400/ HZ
GRUNDFOS DATA BOOKLET CR45-5 A-F-A-E-HQQE 3x4/69 5 HZ Grundfos Pump 9612285 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/9612285/cr-45-5-a-f-a-e-hqqe.html
More informationNB /438 A-F1-A-GQQE
GRUNDFOS DATA BOOKLET NB15-4/438 A-F1-A-GQQE Grundfos pump 983626 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/nb/983626/nb-15-4-438-a-f1-a-e-gqqe.html
More informationHison Axial Flow Fans
Hison Axial Flow Fans Introduction Hison Marine Axial Flow Fans, formerly know as Howden Fans are manufactured to international Quality Standard. Axial flow fans are available from sizes 35mm to 18mm diameter,
More informationCR A-F-A-E-HQQE 3x400/ HZ
GRUNDFOS DATA BOOKLET CR64-3-2 A-F-A-E-HQQE 3x4/69 5 HZ Grundfos Pump 96123531 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/96123531/cr-64-3-2-a-f-a-e-hqqe.html
More informationCR15-10 A-F-A-E-HQQE 11kW 3x400D 50Hz
GRUNDFOS DATA BOOKLET CR15-1 A-F-A-E-HQQE 11kW 3x4D 5Hz Grundfos Pump 965191 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/965191/cr-15-1-a-f-a-e-hqqe.html
More informationMTB /158 A-F-A-BQQV 400D-2 5,5kW
GRUNDFOS DATA BOOKLET MTB 5-1/158 A-F-A-BQQV D- 5,5kW Grundfos pump 95879 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/mtb/95879/mtb-5-1-158-a-f-a-bqqv.html
More informationTP /2-A-F-A-BAQE 400D 50HZ
GRUNDFOS DATA BOOKLET TP 32-38/2-A-F-A-BAQE 4D 5HZ Grundfos Pump 968677 Thank you for your interest in our products Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/tp/968677/tp-32-38-2-a-f-a-baqe.html
More informationCYLINDRICAL CASED AXIAL FLOW FANS
- Adjustable pitch fans Range of adjustable pitch aerofoil blade, cased axial flow fans. Casings formed from rolled sheet steel with a corrosion resistant hot dipped galvanised finish. All models incorporate
More informationBPF. Centrifugal Plug Fans
BPF Centrifugal Plug Fans Introduction INTRODUCTION Plug Fans S&P - THE COMPANY Soler & Palau was founded in 1951 in Ripoll (Spain) and since this date has become one of the world s leading companies engaged
More informationHison Axial Flow Fans
Hison Axial Flow Fans Introduction Hison Marine Axial Flow Fans, formerly know as Howden Fans are manufactured to international Quality Standard. Axial flow fans are available from sizes 35mm to 18mm diameter,
More informationCR A-F-A-E-HQQE 3x400/ HZ
GRUNDFOS DATA BOOKLET CR1-5-1 A-F-A-E-HQQE 3x4/69 5 HZ Grundfos Pump 95922155 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/95922155/cr-1-5-1-a-f-a-e-hqqe.html
More informationCR A-F-A-E-HQQE 3x400/ HZ
GRUNDFOS DATA BOOKLET CR12-4-1 A-F-A-E-HQQE 3x4/69 5 HZ Grundfos Pump 95922154 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/95922154/cr-12-4-1-a-f-a-e-hqqe.html
More informationCONTENTS. Page. Adjustable Axial Pitch Flow Fans 3. Dimensions 4. AP056 Performance Curves 5. AP056 Sound Performance 6. AP063 Performance Curves 7
CONTENTS Page Adjustable Axial Pitch Flow Fans 3 Dimensions 4 AP056 Performance Curves 5 AP056 Sound Performance 6 AP063 Performance Curves 7 AP063 Sound Performance 8 AP071Performance Curves 9 AP071 Sound
More informationCM10-3 A-R-A-E-AVBE F-A-A-N
GRUNDFOS DATA BOOKLET CM1-3 A-R-A-E-AVBE F-A-A-N Grundfos Pump 9686946 Thank you for your interest in our products Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/cmbasis/9686946/cm1-3-a-r-a-e-avbe.html
More informationFLSD (E) Atmospheres containing explosive GAS totally enclosed three-phase asynchronous motors General information
(E) Atmospheres containing explosive GAS General information Flameproof totally enclosed three-phase asynchronous motors, FLSD (E) series, according to IEC 60034, 60038, 60072, 60079-0 and 60079-1, EN
More informationCORE VALUES TECHNOLOGIES ESS-ESD PRODUCT CATALOGUE Enjoy the peace of mind ENGINE POWER SUPPLIERS AND EQUIPMENT HEAT
TECHNOLOGIES ENGINE POWER SUPPLIERS AND EQUIPMENT HEAT Enjoy the peace of mind ESS-ESD PRODUCT CATALOGUE CORE VALUES PEACE OF MIND EFFICIENCY FAIRNESS RESPONSIBILITY CUSTOMER ORIENTATION GROWING DEVELOPED
More informationSERIES R - MD MOR & GOR
SERIES R - MD MOR & GOR CHARACTERISTICS OPTIONS Aluminium alloy construction Surface protection treatment (anodising, only for ATEX 2 versions) Available in monoblock execution (MOR) and with coupling
More informationSquare Duct Fans - ESTOC Range. Estoc Features. Electrical Supply. Product Code. Sizes 355, 400, 450, 500, 560, 630 and 710.
Square Duct Fans - ESTOC Range Features Sizes from 355 to 71 mm diameter Air flow 1,9 m 3 /h (5.2 m 3 /s) Static pressures up to 115 Pa Maximum temperature from +4 C to +7` C (depending on the model) Adjustable
More informationSize and Configurations
!!"#!""!"$%!!" &'()&('& AK Axial Flow Fans the high efficiency direct-driven fan with adjustable pitch impeller specially designed to operate with low noise emission and vibration that meets the stringent
More informationROOF FAN ROOFMASTER STEC
AIR COMFORT AIR MOVEMENT ROOF FANS ROOF FAN ROOFMASTER STEC INSULATED VERSION» TECHNICAL CATALOGUE 2 STEC Roofmaster - Technical Catalogue CONTENTS GENERAL DESCRIPTION Application/specification... 3 Features...
More informationNK40-160/172A1F2AE-SBAQE
GRUNDFOS DATA BOOKLET NK4-16/172A1F2AE-SBAQE Grundfos pump 9782923 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/nkbasis/9782923/nk-4-16-172-a1-f-a-e-baqe.html
More informationCRN15-17 A-FGJ-G-V-HQQV 3x400/ HZ
GRUNDFOS DATA BOOKLET CRN15-17 A-FGJ-G-V-HQQV 3x4/69 5 HZ Grundfos Pump 96526 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn15/96526/crn-15-17-a-fgj-g-v-hqqv.html
More informationCRN A-F-G-V-HQQV 3x400/ HZ
GRUNDFOS DATA BOOKLET CRN32-1-2 A-F-G-V-HQQV 3x4/69 5 HZ Grundfos pump 96122396 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/crn32/96122396/crn-32-1-2-a-f-g-v-hqqv.html
More informationCRN120-3 A-F-G-V-HQQV 3x400/ HZ
GRUNDFOS DATA BOOKLET CRN12-3 A-F-G-V-HQQV 3x4/69 5 HZ Grundfos pump 9592221 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/crn12/9592221/crn-12-3-a-f-g-v-hqqv.html
More informationCR120-2 A-F-A-E-HQQE 3x400/ HZ
GRUNDFOS DATA BOOKLET CR12-2 A-F-A-E-HQQE 3x4/69 5 HZ Grundfos Pump 95922152 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/95922152/cr-12-2-a-f-a-e-hqqe.html
More informationCM10-3 A-R-G-V-AQQV F-A-A-N
GRUNDFOS DATA BOOKLET CM10-3 A-R-G-V-AQQV F-A-A-N Grundfos pump 96806984 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/cmbasis/96806984/cm10-3-a-r-g-v-aqqv.html
More informationShut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.
X X testregistrierung Shut-off dampers Type ATEX-compliant parts and units For low-leakage shut-off of volume flows in potentially explosive atmospheres (ATEX) Circular shut-off dampers for shutting off
More informationAXIAL FANS Axis / Tubo OPERATION MANUAL
TUBO-M AXIS-QA AXIS-Q AXIS-QR AXIS-F AXIS-QRA AXIAL FANS Axis / Tubo OPERATION MANUAL Axis / Tubo www.blaubergventilatoren.de CONTENT 3 Introduction 3 General 3 Safety rules 3 Transport and storage requirements
More informationTechnical data 50 & 60 Hz. Vertical centrifugal pumps Series: DPLHS
Technical data 50 & 60 Hz Vertical centrifugal pumps Series: DPLHS 2 Table of Contents 1 Pump introduction 1.1 General... 4 1.2 Model key... 4 1.3 Description of the product... 4 1.4 Operation... 5 1.5
More informationPACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.
TECHNICAL SELECTION DATA PACKAGE UNIT + o C -10 o C 3 THREE PHASE SCROLL TWO STAGE CENTRIFUGAL LOUVRE LIANT SCROLL RESSOR AXIAL UNIT FEATURES SPECIFICATION SUMMARY Scroll Compressor Multiple Speed Outdoor
More informationTP /2-A-F-A-BQQE 400D 50HZ
GRUNDFOS DATA BOOKLET TP 1-36/2-A-F-A-BQQE 4D 5HZ Grundfos pump 9619194 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/tp/9619194/tp-1-36-2-a-f-a-bqqe.html
More informationCONTRA ROTATING CASED AXIAL FANS TCBBx2 / TCBTx2 Series
Range of cylindrical cased axial fans fitted with aluminium impellers and manufactured from high grade rolled galvanised steel and protected against corrosion by cataforesis primer and black polyester
More information