ExpressBuild STANDARD FAN RANGE

Size: px
Start display at page:

Download "ExpressBuild STANDARD FAN RANGE"

Transcription

1 AIR COMFORT FIRE SAFETY ExpressBuild STANDARD FAN RANGE OUR SHORT LEAD TIME FAN RANGE

2 ExpressBuild CONCEPT & PRINCIPLES When a short lead time solution is important, choose an ExpressBuild Fan product Wide choice of products to meet market performance and commercial needs Our Express Build fan range ONLY uses Preferred Range motors, which we monitor and manage to optimise stock levels to ensure that lead times are as short as possible. Easy to order Just quote our Quick Order s to get your order despatched in 2 working weeks DEDICATED PRODUCTION LINE TO MANUFACTURE OUR REDUCED LEAD TIME FANS. EASY TO ORDER Our core fan range, shown within either our Express Build standard range catalogue or our Fan Selection software, all have Quick Order s assigned to each them, allowing any of these fans to be ordered by just quoting a unique product code making ordering quick and easy CHOOSE THE TEMPERATURE REQUIRED 5ºC, 2ºC, 3ºC, 4ºC CHOOSE THE SIZE OF THE FAN 315mm - 1mm QUOTE THE QUICK ORDER CODE E.G - AJSL-1-23-XX DESPATCH LEAD TIME SERVICE LEVEL Our aim is to fulfil 95% of customer orders within 2 working weeks. During this time scale our target is to process your order, build the product and have it ready for despatch from our UK factory. Where there are high demands for specific items which may extend the lead time beyond this target level, then we will do our best to minimise the delay for the ordered item, or offer an alternative solution on a shorter lead time.

3 The Fläkt Woods ExpressBuild Range Our JM and JMv Axial flow fan products in this range are specifically engineered to meet particular client needs. Our products are manufactured from high quality components to ensure that we deliver a reliable solution. JMv / JM AEROFOIL (STANDARD TEMPERATURE) Designed to provide enhanced performance and efficiency. Axial flow fans are easy to install into ductwork as air enters and leaves the fan in-line with the motor/impeller axis. JMv / JM AEROFOIL HT (SMOKE EXTRACT) Our HT JMv / JM variants are designed for normal ventilation and a one-off emergency smoke extraction capability for temperatures up to 4 C for 2 hours (EN certified). flexibility to suit customer applications with a choice of fan diameters and performances (duty points). Fan Selector Combinations Although our catalogue range offers our customers a wide product choice, our Fan Selection software clearly identifies and offers even more short lead time fan configuration options. Although we only use around 17 different standard (major) component parts, we are able to give customers access to over 4 different fan and motor combinations, allowing us to fulfil a wide range of products needs within a reduced lead time. ExpressBuild Range Offers: 11 fan diameters 5 hub options 4 temperature options 33 motor/speed options 19 solidity options 4128 combinations

4 INCLUDING THE NEW JMV FROM FLÄKT WOODS GAIN THE AERODYNAMIC ADVANTAGE AND SAVE UP TO 24% ON ENERGY COSTS END USER/BUILDING OWNER Proven energy savings Low life cycle costs including low maintenance costs Reduced CO 2 foot print 215 compliant With over 1 years of proven axial fan engineering expertise CONSULTANT Lower energy consumption through improved aerodynamic efficiency Lower carbon emissions supporting BREEAM ratings 215 compliant Advanced Fan Selector Tool - makes selecting the most energy efficient solution easy CONTRACTOR Easy installation In-house expertise from trained engineers to support your needs A wide range available Online supporting material Energy saving for your customers 215 compliant Lowering Energy Costs - Reducing Your Carbon Footprint - Engineering Expertise

5 5 CONTENTS CASED AXIALS - JM AEROFOIL...8 HIGH EFFICIENCY CASED AXIALS - JMv AEROFOIL...9 CASED AXIALS - HTJM & JMv AEROFOIL (F2, F3 & F4)...1 5ºC QUICK SELECTION CHARTS PH Std Temperature JMv 315mm-355mm 2 POLE...13 Performance Chart...13 Performance Table...13 and Electrical Table PH Std Temperature JMv 4mm 2 POLE...14 Performance Chart...14 Performance Table...14 and Electrical Table PH Std Temperature JMv 45mm 2 POLE...15 Performance Chart...15 Performance Table...15 and Electrical Table PH Std Temperature JMv 5mm 2 POLE...16 Performance Chart...16 Performance Table...16 and Electrical Table PH Std Temperature JMv 58mm 2 POLE Performance Chart Performance Table and Electrical Table PH Std Temperature JM 63mm 2 POLE...18 Performance Chart...18 Performance Table...18 and Electrical Table PH Std Temperature JMv 315mm - 5mm 4 POLE...19 Performance Chart...19 Performance Table...19 and Electrical Table PH Std Temperature JMv 56mm & 63mm 4 POLE...2 Performance Chart...2 Performance Table...2 and Electrical Table...2 3PH Std Temperature JM 71mm - 6 Blades 4 POLE...21 Performance Chart...21 Performance Table...21 and Electrical Table PH Std Temperature JM 71mm - 9 blades 4 POLE...22 Performance Chart...22 Performance Table...22 and Electrical Table PH Std Temperature JM 8mm - 6 blades 4 POLE...23 Performance Chart...23 Performance Table...23 and Electrical Table PH Std Temperature JM 8mm - 9 blades 4 POLE Performance Chart Performance Table and Electrical Table PH Std Temperature JM 9mm - 6 blades 4 POLE...25 Performance Chart...25 Performance Table...25 and Electrical Table PH Std Temperature JM 9mm - 9 blades 4 POLE...26 Performance Chart...26 Performance Table...26 and Electrical Table PH Std Temperature JM 1mm - 25mm hub 4 POLE...27 Performance Chart...27 Performance Table...27 and Electrical Table PH Std Temperature JM 1mm - 315mm hub 4 POLE...28 Performance Chart...28 Performance Table...28 and Electrical Table ºC QUICK SELECTION CHARTS PH 2ºC/2hrs HTJMv - 4mm & 45mm 2 POLE...31 Performance Chart...31 Performance Table...31 and Electrical Table PH 2ºC/2hrs HTJMv - 5mm & 56mm 2 POLE...32 Performance Chart...32 Performance Table...32 and Electrical Table PH 2ºC/2hrs HTJMv - 63mm 2 POLE...33 Performance Chart...33 Performance Table...33 and Electrical Table PH 2ºC/2hrs HTJMv - 4mm, 45mm & 5mm 4 POLE Performance Chart Performance Table and Electrical Table PH 2ºC/2hrs HTJMv - 56mm & 63mm 4 POLE...35 Performance Chart...35 Performance Table...35 and Electrical Table...35

6 6 3PH 2ºC/2hrs HTJM - 71mm - 6 blades 4 POLE...36 Performance Chart...36 Performance Table...36 and Electrical Table PH 2ºC/2hrs HTJM - 71mm - 9 blades 4 POLE Performance Chart Performance Table and Electrical Table PH 2ºC/2hrs HTJM - 8mm - 6 blades 4 POLE...38 Performance Chart...38 Performance Table...38 and Electrical Table PH 2ºC/2hrs HTJM - 8mm - 9 blades 4 POLE...39 Performance Chart...39 Performance Table...39 and Electrical Table PH 2ºC/2hrs HTJM - 9mm - 6 blades 4 POLE... 4 Performance Chart... 4 Performance Table... 4 and Electrical Table PH 2ºC/2hrs HTJM - 9mm - 9 blades 4 POLE...41 Performance Chart...41 Performance Table...41 and Electrical Table PH 2ºC/2hrs HTJM - 1mm - 25mm hub 4 POLE Performance Chart Performance Table and Electrical Table PH 2ºC/2hrs HTJM - 1mm - 315mm hub 4 POLE Performance Chart Performance Table and Electrical Table ºC QUICK SELECTION CHARTS PH 3ºC/2hrs HTJM - 315mm, 355mm & 4mm 2 POLE Performance Chart Performance Table and Electrical Table PH 3ºC/2hrs HTJMv - 45mm & 5mm 2 POLE...47 Performance Chart...47 Performance Table...47 and Electrical Table PH 3ºC/2hrs HTJMv - 56mm & 63mm 2 POLE Performance Chart Performance Table and Electrical Table PH 3ºC/2hrs JMv 4mm - 63mm 4 POLE Performance Chart Performance Table and Electrical Table PH 3ºC/2hrs HTJM - 71mm 2mm hub 4 POLE...5 Performance Chart...5 Performance Table...5 and Electrical Table...5 3PH 3ºC/2hrs HTJM - 71mm 25mm hub 4 POLE...51 Performance Chart...51 Performance Table...51 and Electrical Table PH 3ºC/2hrs HTJM - 8mm 2mm hub 4 POLE...52 Performance Chart...52 Performance Table...52 and Electrical Table PH 3ºC/2hrs HTJM - 8mm 25mm hub 4 POLE...53 Performance Chart...53 Performance Table...53 and Electrical Table PH 3ºC/2hrs HTJM - 9mm 25mm hub 4 POLE Performance Chart Performance Table and Electrical Table PH 3ºC/2hrs HTJM - 1mm 25mm hub 4 POLE...55 Performance Chart...55 Performance Table...55 and Electrical Table PH 3ºC/2hrs HTJM - 1mm 315mm hub 4 POLE...56 Performance Chart...56 Performance Table...56 and Electrical Table ºC QUICK SELECTION CHARTS PH 4ºC/2hrs HTJMv - 315mm - 4mm 2 POLE...59 Performance Chart...59 Performance Table...59 and Electrical Table PH 4ºC/2hrs HTJMv - 4mm-63mm 2 POLE...6 Performance Chart...6 Performance Table...6 and Electrical Table...6 3PH 4ºC/2hrs HTJM - 71mm 4 POLE...61 Performance Chart...61 Performance Table...61 and Electrical Table...61

7 7 3PH 4ºC/2hrs HTJM-8mm 2mm hub, 3&6 blades 4 POLE 62 Performance Chart...62 Performance Table...62 and Electrical Table PH 4ºC/2hrs HTJM - 8mm 25mm hub, 6 blades 4 POLE...63 Performance Chart...63 Performance Table...63 and Electrical Table PH 4ºC/2hrs HTJM - 8mm 25mm hub, 9 blades 4 POLE Performance Chart Performance Table and Electrical Table PH 4ºC/2HRS HTJM - 9MM 4 POLE...65 Performance Chart...65 Performance Table...65 and Electrical Table PH 4ºC/2hrs HTJM - 1mm 4 POLE...66 Performance Chart...66 Performance Table...66 and Electrical Table...66 IDDXF54 HVAC Three Phase IP WIRING DIAGRAMS DRAWINGS Drawing dimensions - 5ºC Fans...72 Drawing dimensions - 2ºC Fans Drawing dimensions - 3ºC Fans...74 Drawing dimensions - 4ºC Fans CASED AXIAL - ACCESSORIES JM/JMv Matching Flange and Flexible Connector JM/JMv Mounting Feet (set of 2) JM/JMv Damper JM/JMv Bellmouth Inlet - fan with flanged inlet only...77 JM/JMv Guard...77 Silencer Rubber in Shear Anti-Vibration Mounts Enclosed Spring Anti-Vibration Mounts...8 USEFUL INFORMATION Installation Advice - Horizontal Mounting...81 Installation Advice - Vertical Mounting...82 Installation Advice - Bends, Expanders & Contractors...83 Installation Advice - Inlet & Outlets Air Changes Per Hour...85 Fume Removal...85 Conversion...86

8 8 CASED AXIALS - JM AEROFOIL FEATURES mm diameter Air flow up to 24. m 3 /s Static pressures up to 117 Pa Fans tested to ISO581 and BS848 High energy efficiency Low installed noise levels Motor protection and terminal box IP55 ELECTRICAL SUPPLY 38-42V/5Hz/3φ TEMPERATURE RANGE Standard Operating temperature range: -4ºC to 5ºC, plus a one off emergency use at 2ºC for 2 hours (3 ph motors). Where fans need to operate between 5ºC and 7ºC, fans must be run at full speed only. SIZES 315, 355, 4, 45, 5, 56, 63, 71, 8, 9 and 1 mm. IMPELLERS A unique high efficiency aerofoil section blade with a smoothed hub and clamp plate for adjustable pitch angle availability. The Fläkt Woods impellers are all high pressure die cast to offer thin aerofoil sections for low generation of noise. Every cast aluminium component is X-ray examined using Real Time Radiography inspection prior to assembly. The maximum pitch angles shown are based on speed control by frequency inverter. This range is available in Form B only (air entering the impeller first). MOTORS All motors are totally enclosed air stream rated with class F insulation. Constructed from aluminium or cast iron as standard, with special T slot or pad mount fixings. Suitable for horizontal or vertical shaft operation. Motors are supplied as IP55 as standard, with removable drain plugs. Bearings are of the sealed for life type and are lubricated with grease which has a wide operating temperature range, designed for optimal performance. Our BT and CT frames are fitted with overheat protection thermostats as standard, while 8 to 16 frame motors are fitted with Thermistor OHP. These motors are suitable for inverter\speed control down to 2% of full speed and where within scope incorporate IE2 or IE3 efficiency grade motors. CASINGS JM Aerofoil fans within our Express Build range are available in long cased form, complete with an externally mounted pre-wired electrical terminal box. Casings are spun from sheet steel with integral pre-drilled and radiused inlet flanges. The galvanised finish gives a high resistance to corrosion and is ideal for external as well as internal use. PRODUCT CODE 63JM/2/4/6/ denotes the fan impeller diameter in centimetres JM - denotes fan type 2 - denotes impeller hub diameter in centimetres 4 - denotes a nominal 4 pole speed 6 - denotes the number of blades 36 - denotes the pitch angle for the required duty ACCESSORIES & CONTROLLERS Damper Mounting Feet Guard Rubber AV s Bellmouth Spring AV s Flange Flexible Connector Silencer s

9 9 HIGH EFFICIENCY CASED AXIALS - JMv AEROFOIL FEATURES mm Volume up to 6.2 m 3 /s Static pressures up to 118 Pa Fans tested to ISO581 and BS848 High energy efficiency Low installed noise levels Motor protection and terminal box IP55 Overheat protection fitted as standard ELECTRICAL SUPPLY 38-42V/5Hz/3 TEMPERATURE RANGE Standard Operating temperature range: -4ºC to 5ºC, plus a one off emergency use at 2ºC for 2 hours (3 ph motors). Where fans need to operate between 5ºC and 7ºC, fans must be run at full speed only. SIZES 315, 355, 4, 45, 5, 56 and 63 mm. IMPELLERS Our impeller design includes features such as our unique high efficiency, high twist aerofoil section blades, which are fitted into an aerodynamically optimised hub and clamp plate, that allows pitch angles to be adjusted to precisely match customer needs. Fläkt Woods impeller blades are all manufactured from either high pressure die cast aluminium or high quality gravity die casting process, which enables us to offer thin aerofoil sections that reduce noise generation. Every cast aluminium component is X-ray examined using Real Time Radiography inspection prior to assembly to ensure that high quality is maintained. The maximum pitch angles shown are based on speed control by frequency inverter. This range is available in Form B only (air entering the impeller first). CASINGS JMv Aerofoil fans are available in a long cased form, complete with an externally mounted pre-wired electrical terminal box. Casings are spun from sheet steel with integral pre-drilled and radiused inlet flanges. The galvanised finish gives a high resistance to corrosion and is ideal for external as well as internal use. PRODUCT CODE 63JMv/2/4/6/35 63 JMv denotes the fan impeller diameter in centimetres - denotes fan type - denotes impeller hub diameter in centimetres - denotes a nominal 4 pole speed - denotes the number of blades - denotes the pitch angle for the required duty ACCESSORIES & CONTROLLERS GAIN THE AERODYNAMIC ADVANTAGE AND SAVE UP TO 24% ON ENERGY COSTS MOTORS All motors are totally enclosed air stream rated with class F insulation. Constructed from aluminium or cast iron as standard, with special T slot or pad mount fixings. Suitable for horizontal or vertical shaft operation. Motors are supplied as IP55 as standard,with removable drain plugs. Bearings are of the sealed for life type and are lubricated with grease which has a wide operating temperature range, designed for optimal performance. Our BT and CT frames are fitted with overheat protection thermostats as standard, while 8 to 16 frame motors are fitted with Thermistor OHP. These motors are suitable for inverter\speed control down to 2% of full speed and where within scope incorporate IE2 or IE3 efficiency grade motors. Damper Guard Bellmouth Flange Mounting Feet Rubber AV s Spring AV s Flexible Connector Silencer s

10 1 CASED AXIALS - HT JM & JMv AEROFOIL (F2, F3 and F4) FEATURES mm diameter Air flow up to 24 m 3 /s Static pressures up to 117 Pa IP55 motor rating Fans tested to ISO581 and BS848 High energy efficiency Low installed noise levels Motor protection and terminal box IP55 ELECTRICAL SUPPLY 38-42V/5Hz/3φ TEMPERATURE RANGE -4ºC to 5ºC as standard. This range is also suitable for Smoke Extraction, rated for 2 C, 3 C or 4 C for a duration of 2 hours - one off emergency operation only. Fans comply with high temperature test standard: EN SIZES 355, 4, 45, 5, 56, 63, 71, 8, 9 and 1 mm. IMPELLERS Our impeller design includes features such as our unique high efficiency, high twist aerofoil section blades (JMv), which are fitted into an aerodynamically optimised hub and clamp plate, that allows pitch angles to be adjusted to precisely match customer needs. Fläkt Woods impeller blades are all manufactured from high pressure die cast aluminium, which enables us to offer thin aerofoil sections that reduce noise generation. Every cast aluminium component is X-ray examined using Real Time Radiography inspection prior to assembly to ensure that high quality is maintained. The maximum pitch angles shown are based on speed control by frequency inverter. When using an inverter with a dual mode fan which is capable of delivering both a normal ventilation and HT smoke extraction functions, the inverter must be switched out of circuit during a fire scenario. This range is available in Form B only (air entering the impeller first) MOTORS Fläkt Woods HT Series fans utilise a totally enclosed squirrel cage motor design which features insulation standards selected to specifically meet the requirements of each HT Category. These motors are suitable for inverter\speed control down to 2% of full speed. Motors are either IE2 or IE3 efficiency grade as stated within the technical data shown. Fläkt Woods HT Series fan motors are capable of allowing fans to be run continuously at normal ambient temperatures (-4 C to 5 C), as well as operating at their emergency high temperature category (once off usage). See temperature range for details. Note: During emergency use the inverter should be by-passed and the fan run at full speed. CASINGS HT JM & JMv Aerofoil fans are available in long cased form, complete with an externally mounted pre-wired electrical terminal box. Casings are spun from sheet steel with integral pre-drilled and radiused inlet flanges. The galvanised finish gives a high resistance to corrosion and is ideal for external as well as internal use. PRODUCT CODE HT63JM/2/4/6/36 HT - denotes high temperature fan 63 - denotes the fan impeller diameter in centimetres JM - denotes axial fan family 2 - denotes impeller hub diameter in centimetres 4 - denotes a nominal 4 pole speed 6 - denotes the number of blades 36 - denotes the pitch angle for the required duty ACCESSORIES & CONTROLLERS Damper Guard Bellmouth Flange Mounting Feet TEMPERATURE RANGE Fans are tested in compliance with high temperature test standard directive 89/16/EEC to EN , and are fully CE marked accordingly. Silencer Spring AV s Rubber AV s (2 C ) Flexible Connector s

11 ºC QUICK SELECTION CHARTS 12 Express Build - 3ph Std Temperature fans 2 pole 315mm to 63mm Range Overview - Quick Fan diameter selection m3/hr Express Build - 3ph Std Temperature fans 4 pole 315mm to 63mm Range Overview - Quick Fan diameter selection m3/hr

12 12 5ºC QUICK SELECTION CHARTS 9 Express Build - 3ph Std Temperature fans 4 pole 71mm to 1mm Range Overview - Quick Fan diameter selection m3/hr

13 13 3PH STD TEMPERATURE JMv - 315MM & 355MM 2 POLE JMv/14/2/6/ JMv/14/2/6/ JMv/14/2/6/ m3/hr JMv/14/2/6/ JMv/14/2/6/ JMv/14/2/6/ Unique rev/min Pole Motor (kw) 1 31JMv/14/2/6/33 AVAL-1-1-XX BT9 (IE1) CD32 N/A JMv/14/2/6/3 AVAL-1-2-XX (IE2) CD32 IDDXF JMv/14/2/6/4 AVAL-1-3-XX (IE2) CD32 IDDXF Note - XX in Unique denotes impeller pitch angle, which must be a value between the P/A and For efficiency ratings and grades please refer to our Fan Selector for more information. conditions. These are presented for comparative purposes only.

14 14 3PH STD TEMPERATURE JMv - 4MM 2 POLE JMv/16/2/6/ JMv/16/2/6/22 6 4JMv/16/2/6/ m3/hr JMv/16/2/6/ JMv/16/2/6/ JMv/16/2/6/ Unique rev/min Phase Motor (kw) 4 4JMv/16/2/6/14 AVAL-1-4-XX (IE2) CD32 IDDXF JMv/16/2/6/22 AVAL-1-5-XX (IE2) CD32 IDDXF JMv/16/2/6/29 AVAL-1-6-XX (IE2) CD32 IDDXF Note - XX in Unique denotes impeller pitch angle, which must be a value between the P/A and For efficiency ratings and grades please refer to our Fan Selector for more information. conditions. These are presented for comparative purposes only.

15 15 3PH STD TEMPERATURE JMv - 45MM 2 POLE JMv/16/2/6/ JMv/16/2/6/ m3/hr JMv/16/2/6/ JMv/16/2/6/ Unique rev/min Phase Motor (kw) 7 45JMv/16/2/6/17 AVAL-1-7-XX (IE2) CD32 IDDXF JMv/16/2/6/32 AVAL-1-8-XX L9L (IE2) CD32 IDDXF Note - XX in Unique denotes impeller pitch angle, which must be a value between the P/A and For efficiency ratings and grades please refer to our Fan Selector for more information. conditions. These are presented for comparative purposes only.

16 16 3PH STD TEMPERATURE JMv - 5MM 2 POLE JMv/16/2/6/19 1 5JMv/2/2/6/3 11 5JMv/2/2/6/ m3/hr JMv/16/2/6/ JMv/2/2/6/ JMv/2/2/6/ Unique rev/min Phase Motor (kw) 9 5JMv/16/2/6/19 AVAL-1-9-XX L9L (IE2) CD32 IDDXF JMv/2/2/6/3 AVAL-1-1-XX M (IE2) CD318 IDDXF JMv/2/2/6/39 AVAL-1-11-XX L112M (IE2) CD318 IDDXF Note - XX in Unique denotes impeller pitch angle, which must be a value between the P/A and For efficiency ratings and grades please refer to our Fan Selector for more information. conditions. These are presented for comparative purposes only.

17 17 3PH STD TEMPERATURE JMv 56MM 2 POLE JMv/2/2/6/ JMv/2/2/6/ m3/hr JMv/2/2/6/ JMv/2/2/6/ Unique rev/min Phase Motor (kw) 12 56JMv/2/2/6/17 AVAL-1-12-XX M (IE2) CD318 IDDXF JMv/2/2/6/24 AVAL-1-13-XX L112M (IE2) cd318 IDDXF Note - XX in Unique denotes impeller pitch angle, which must be a value between the P/A and For efficiency ratings and grades please refer to our Fan Selector for more information. conditions. These are presented for comparative purposes only.

18 18 3PH STD TEMPERATURE JM 63MM 2 POLE JM/25/2/3/ JM/25/2/3/ m3/hr JM/25/2/3/ JM/25/2/3/ Unique rev/min Phase Motor (kw) 14 63JM/25/2/3/22 AJSL-1-1-XX M (IE2) CD2417 IDDXF JM/25/2/3/28 AJSL-1-2-XX L112M (IE2) CD2417 IDDXF Note - XX in Unique denotes impeller pitch angle, which must be a value between the P/A and For efficiency ratings and grades please refer to our Fan Selector for more information. conditions. These are presented for comparative purposes only.

19 19 3PH STD TEMPERATURE JMv 315MM TO 5MM 4 POLE JMv/2/4/6/ JMv/16/4/6/ JMv/16/4/6/ JMv/14/4/6/ JMv/14/4/6/ m3/hr JMv/14/4/6/ JMv/14/4/6/ JMv/16/4/6/ JMv/16/4/6/ JMv/2/4/6/ Unique rev/min Phase Motor (kw) 16 31JMv/14/4/6/4 AVAL-1-14-XX BT4 (IE1) CD32 IDDXF JMv/14/4/6/8 AVAL-1-15-XX BT4 (IE1) CD32 N/A JMv/16/4/6/4 AVAL-1-16-XX (IE2) CD32 IDDXF JMv/16/4/6/35 AVAL-1-17-XX (IE2) CD32 IDDXF JMv/2/4/6/34 AVAL-1-18-XX (IE2) CD32 IDDXF Note - XX in Unique denotes impeller pitch angle, which must be a value between the P/A and For efficiency ratings and grades please refer to our Fan Selector for more information. conditions. These are presented for comparative purposes only.

20 2 3PH STD TEMPERATURE JMv - 56MM & 63MM 4 POLE JMv/2/4/6/ JMv/2/4/6/ JMv/2/4/6/ m3/hr JMv/2/4/6/ JMv/2/4/6/ JMv/2/4/6/ Unique rev/min Phase Motor (kw) 21 56JMv/2/4/6/35 AVAL-1-19-XX L (IE2) CD32 IDDXF JMv/2/4/6/24 AVAL-1-2-XX L (IE2) CD32 IDDXF JMv/2/4/6/33 AVAL-1-21-XX L (IE2) CD32 IDDXF Note - XX in Unique denotes impeller pitch angle, which must be a value between the P/A and For efficiency ratings and grades please refer to our Fan Selector for more information. conditions. These are presented for comparative purposes only.

21 21 3PH STD TEMPERATURE JM - 71MM - 6 BLADES 4 POLE JM/2/4/6/ JM/2/4/6/ JM/2/4/6/ m3/hr JM/2/4/6/ JM/2/4/6/ JM/2/4/6/ Unique rev/min Phase Motor (kw) 3 71JM/2/4/6/22 AJSL-1-3-XX L (IE2) CD2416 IDDXF JM/2/4/6/3 AJSL-1-4-XX L (IE2) CD2416 IDDXF JM/2/4/6/36 AJSL-1-5-XX M (IE2) CD2417 IDDXF Note - XX in Unique denotes impeller pitch angle, which must be a value between the P/A and For efficiency ratings and grades please refer to our Fan Selector for more information. conditions. These are presented for comparative purposes only.

22 22 3PH STD TEMPERATURE JM - 71MM - 9 BLADES 4 POLE JM/25/4/9/ JM/25/4/9/ JM/25/4/9/ m3/hr JM/25/4/9/ JM/25/4/9/ JM/25/4/9/ Unique rev/min Phase Motor (kw) 33 71JM/25/4/9/2 AJSL-1-6-XX L (IE2) CD2416 IDDXF JM/25/4/9/28 AJSL-1-7-XX L (IE2) CD2416 IDDXF JM/25/4/9/34 AJSL-1-8-XX M (IE2) CD2417 IDDXF Note - XX in Unique denotes impeller pitch angle, which must be a value between the P/A and For efficiency ratings and grades please refer to our Fan Selector for more information. conditions. These are presented for comparative purposes only.

23 23 3PH STD TEMPERATURE JM - 8MM - 6 BLADES 4 POLE JM/2/4/6/ JM/2/4/6/ m3/hr JM/2/4/6/ JM/2/4/6/ Unique rev/min Phase Motor (kw) 36 8JM/2/4/6/18 AJSL-1-9-XX L (IE2) CD2416 IDDXF JM/2/4/6/24 AJSL-1-1-XX M (IE2) CD2417 IDDXF Note - XX in Unique denotes impeller pitch angle, which must be a value between the P/A and For efficiency ratings and grades please refer to our Fan Selector for more information. conditions. These are presented for comparative purposes only.

24 24 3PH STD TEMPERATURE JM - 8MM - 9 BLADES 4 POLE JM/25/4/9/28 4 8JM/25/4/9/ JM/25/4/9/ m3/hr JM/25/4/9/ JM/25/4/9/ JM/25/4/9/ Unique rev/min Phase Motor (kw) 38 8JM/25/4/9/22 AJSL-1-11-XX M (IE2) CD2417 IDDXF JM/25/4/9/28 AJSL-1-12-XX L112M (IE2) CD2417 IDDXF JM/25/4/9/36 AJSL-1-13-XX M (IE2) CD2417 IDDXF Note - XX in Unique denotes impeller pitch angle, which must be a value between the P/A and For efficiency ratings and grades please refer to our Fan Selector for more information. conditions. These are presented for comparative purposes only.

25 25 3PH STD TEMPERATURE JM 9MM - 6 BLADES 4 POLE JM/25/4/6/ JM/25/4/6/2 43 9JM/25/4/6/ m3/hr JM/25/4/6/ JM/25/4/6/ JM/25/4/6/ Unique rev/min Phase Motor (kw) 41 9JM/25/4/6/2 AJSL-1-14-XX M (IE2) CD2417 IDDXF JM/25/4/6/26 AJSL-1-15-XX L112M (IE2) CD2417 IDDXF JM/25/4/6/32 AJSL-1-16-XX M (IE2) CD2417 IDDXF Note - XX in Unique denotes impeller pitch angle, which must be a value between the P/A and For efficiency ratings and grades please refer to our Fan Selector for more information. conditions. These are presented for comparative purposes only.

26 26 3PH STD TEMPERATURE JM - 9MM - 9 BLADES 4 POLE JM/25/4/9/ JM/25/4/9/ m3/hr JM/25/4/9/ JM/25/4/9/ Unique rev/min Phase Motor (kw) 44 9JM/25/4/9/18 AJSL-1-17-XX L112M (IE2) CD2417 IDDXF JM/25/4/9/24 AJSL-1-18-XX M (IE2) CD2417 IDDXF Note - XX in Unique denotes impeller pitch angle, which must be a value between the P/A and For efficiency ratings and grades please refer to our Fan Selector for more information. conditions. These are presented for comparative purposes only.

27 27 3PH STD TEMPERATURE JM - 1MM - 25MM HUB 4 POLE JM/25/4/6/ JM/25/4/9/ m3/hr JM/25/4/6/ JM/25/4/9/ Unique rev/min Phase Motor (kw) 46 1JM/25/4/6/22 AJSL-1-19-XX M (IE2) CD2417 IDDXF JM/25/4/9/14 AJSL-1-2-XX M (IE2) CD2417 IDDXF Note - XX in Unique denotes impeller pitch angle, which must be a value between the P/A and For efficiency ratings and grades please refer to our Fan Selector for more information. conditions. These are presented for comparative purposes only.

28 28 3PH STD TEMPERATURE JM - 1MM - 315MM HUB 4 POLE JM/31/4/9/ JM/31/4/9/22 5 1JM/31/4/9/ JM/31/4/9/ m3/hr JM/31/4/9/ JM/31/4/9/ JM/31/4/9/ JM/31/4/9/ Unique rev/min Phase Motor (kw) 48 1JM/31/4/9/14 AJSL-1-21-XX M (IE2) CD2417 IDDXF JM/31/4/9/22 AJSL-1-22-XX M (IE2) CD2417 IDDXF JM/31/4/9/28 AJSL-1-23-XX L (IE2) CD2417 IDDXF JM/31/4/9/36 AJSL-1-24-XX L (IE2) CD2417 IDDXF Note - XX in Unique denotes impeller pitch angle, which must be a value between the P/A and For efficiency ratings and grades please refer to our Fan Selector for more information. conditions. These are presented for comparative purposes only.

29 ºC QUICK SELECTION CHARTS 12 Express Build- 3ph HT2º C/2hrs Smoke Venting fans 2 pole 4mm to 63mm Range Overview - Quick Fan diameter selection m3/hr 4 Express Build - 3ph HT2º C/2hrs Smoke Venting fans 4 pole 4mm to 63mm Range Overview - Quick Fan diameter selection m3/hr

30 1 3 2ºC QUICK SELECTION CHARTS 9 Express Build - 3ph HT2º C/2hrs Smoke Venting fans 4 pole 71mm to 1mm Range Overview - Quick Fan diameter selection m3/hr

31 31 3PH 2ºC/2HRS HT JMv - 4MM & 45MM 2 POLE HT45JMv/16/2/6/ HT4JMv/16/2/6/14 62 HT4JMv/16/2/6/29 61 HT4JMv/16/2/6/22 64 HT45JMv/16/2/6/ m3/hr HT4JMv/16/2/6/ HT4JMv/16/2/6/ HT4JMv/16/2/6/ HT45JMv/16/2/6/ HT45JMv/16/2/6/ Unique rev/min Phase Motor (kw) 6 HT4JMv/16/2/6/14 AVHL-2-1-XX (IE2) CD32 IDDXF HT4JMv/16/2/6/22 AVHL-2-2-XX (IE2) CD32 IDDXF HT4JMv/16/2/6/29 AVHL-2-3-XX (IE2) CD32 IDDXF HT45JMv/16/2/6/17 AVHL-2-4-XX (IE2) CD32 IDDXF HT45JMv/16/2/6/32 AVHL-2-5-XX L9L (IE2) CD32 IDDXF Note - XX in Unique denotes impeller pitch angle, which must be a value between the P/A and s can be used for Dual Mode High Temperature fans when fan is operating as a standard ventilation fan. s must be switched out of circuit during a fire scenario. For efficiency ratings and grades please refer to our Fan Selector for more information. conditions. These are presented for comparative purposes only.

32 32 3PH 2ºC/2HRS HT JMv - 5MM & 56MM 2 POLE HT56JMv/2/2/6/ HT5JMv/16/2/6/ m3/hr HT5JMv/16/2/6/ HT56JMv/2/2/6/ Unique rev/min Phase Motor (kw) 65 HT5JMv/16/2/6/19 AVHL-2-6-XX L9L (IE2) CD32 IDDXF HT56JMv/2/2/6/17 AVHL-2-7-XX M (IE2) CD318 IDDXF Note - XX in Unique denotes impeller pitch angle, which must be a value between the P/A and s can be used for Dual Mode High Temperature fans when fan is operating as a standard ventilation fan. s must be switched out of circuit during a fire scenario. For efficiency ratings and grades please refer to our Fan Selector for more information. conditions. These are presented for comparative purposes only.

33 33 3PH 2ºC/2HRS HT JM - 63MM 2 POLE HT63JM/25/2/3/ HT63JM/25/2/3/ m3/hr HT63JM/25/2/3/ HT63JM/25/2/3/ Unique rev/min Phase Motor (kw) 67 HT63JM/25/2/3/22 AJHL-2-1-XX M (IE2) CD2417 IDDXF HT63JM/25/2/3/28 AJHL-2-2-XX L112M (IE2) CD2417 IDDXF Note - XX in Unique denotes impeller pitch angle, which must be a value between the P/A and s can be used for Dual Mode High Temperature fans when fan is operating as a standard ventilation fan. s must be switched out of circuit during a fire scenario. For efficiency ratings and grades please refer to our Fan Selector for more information. conditions. These are presented for comparative purposes only.

34 34 3PH 2ºC/2HRS HT JMv - 4MM, 45MM & 5MM 4 POLE HT45JMv/16/4/6/35 71 HT5JMv/2/4/6/ HT4JMv/16/4/6/ m3/hr HT4JMv/16/4/6/ HT45JMv/16/4/6/ HT5JMv/2/4/6/ Unique rev/min Phase Motor (kw) 69 HT4JMv/16/4/6/4 AVHL-2-8-XX (IE2) CD32 IDDXF HT45JMv/16/4/6/35 AVHL-2-9-XX (IE2) CD32 IDDXF HT5JMv/2/4/6/34 AVHL-2-1-XX (IE2) CD32 IDDXF Note - XX in Unique denotes impeller pitch angle, which must be a value between the P/A and s can be used for Dual Mode High Temperature fans when fan is operating as a standard ventilation fan. s must be switched out of circuit during a fire scenario. For efficiency ratings and grades please refer to our Fan Selector for more information. conditions. These are presented for comparative purposes only.

35 35 3PH 2ºC/2HRS HT JMv - 56MM & 63MM 4 POLE HT63JMv/2/4/6/ HT56JMv/2/4/6/35 74 HT63JMv/2/4/6/ m3/hr HT56JMv/2/4/6/ HT63JMv/2/4/6/ HT63JMv/2/4/6/ Unique rev/min Phase Motor (kw) 72 HT56JMv/2/4/6/35 AVHL-2-11-XX L (IE2) CD32 IDDXF HT63JMv/2/4/6/24 AVHL-2-12-XX L (IE2) CD32 IDDXF HT63JMv/2/4/6/33 AVHL-2-13-XX L (IE2) CD32 IDDXF Note - XX in Unique denotes impeller pitch angle, which must be a value between the P/A and s can be used for Dual Mode High Temperature fans when fan is operating as a standard ventilation fan. s must be switched out of circuit during a fire scenario. For efficiency ratings and grades please refer to our Fan Selector for more information. conditions. These are presented for comparative purposes only.

36 36 3PH 2ºC/2HRS HT JM - 71MM - 6 BLADES 4 POLE HT71JM/2/4/6/22 91 HT71JM/2/4/6/3 92 HT71JM/2/4/6/ m3/hr HT71JM/2/4/6/ HT71JM/2/4/6/ HT71JM/2/4/6/ Unique rev/min Phase Motor (kw) 9 HT71JM/2/4/6/22 AJHL-2-3-XX L (IE2) CD2416 IDDXF HT71JM/2/4/6/3 AJHL-2-4-XX L (IE2) CD2416 IDDXF HT71JM/2/4/6/36 AJHL-2-5-XX M (IE2) CD2417 IDDXF Note - XX in Unique denotes impeller pitch angle, which must be a value between the P/A and s can be used for Dual Mode High Temperature fans when fan is operating as a standard ventilation fan. s must be switched out of circuit during a fire scenario. For efficiency ratings and grades please refer to our Fan Selector for more information. conditions. These are presented for comparative purposes only.

37 37 3PH 2ºC/2HRS HT JM - 71MM - 9 BLADES 4 POLE HT71JM/25/4/9/2 94 HT71JM/25/4/9/28 95 HT71JM/25/4/9/ m3/hr HT71JM/25/4/9/ HT71JM/25/4/9/ HT71JM/25/4/9/ Unique rev/min Phase Motor (kw) 93 HT71JM/25/4/9/2 AJHL-2-6-XX L (IE2) CD2416 IDDXF HT71JM/25/4/9/28 AJHL-2-7-XX L (IE2) CD2416 IDDXF HT71JM/25/4/9/34 AJHL-2-8-XX M (IE2) CD2417 IDDXF Note - XX in Unique denotes impeller pitch angle, which must be a value between the P/A and s can be used for Dual Mode High Temperature fans when fan is operating as a standard ventilation fan. s must be switched out of circuit during a fire scenario. For efficiency ratings and grades please refer to our Fan Selector for more information. conditions. These are presented for comparative purposes only.

38 38 3PH 2ºC/2HRS HT JM - 8MM - 6 BLADES 4 POLE HT8JM/2/4/6/18 97 HT8JM/2/4/6/ m3/hr HT8JM/2/4/6/ HT8JM/2/4/6/ Unique rev/min Phase Motor (kw) 96 HT8JM/2/4/6/18 AJHL-2-9-XX L (IE2) CD2416 IDDXF HT8JM/2/4/6/24 AJHL-2-1-XX M (IE2) CD2417 IDDXF Note - XX in Unique denotes impeller pitch angle, which must be a value between the P/A and s can be used for Dual Mode High Temperature fans when fan is operating as a standard ventilation fan. s must be switched out of circuit during a fire scenario. For efficiency ratings and grades please refer to our Fan Selector for more information. conditions. These are presented for comparative purposes only.

39 39 3PH 2ºC/2HRS HT JM - 8MM - 9 BLADES 4 POLE HT8JM/25/4/9/22 99 HT8JM/25/4/9/28 1 HT8JM/25/4/9/ m3/hr HT8JM/25/4/9/ HT8JM/25/4/9/ HT8JM/25/4/9/ Unique rev/min Phase Motor (kw) 98 HT8JM/25/4/9/22 AJHL-2-11-XX M (IE2) CD2417 IDDXF HT8JM/25/4/9/28 AJHL-2-12-XX L112M (IE2) CD2417 IDDXF HT8JM/25/4/9/36 AJHL-2-13-XX M (IE2) CD2417 IDDXF Note - XX in Unique denotes impeller pitch angle, which must be a value between the P/A and s can be used for Dual Mode High Temperature fans when fan is operating as a standard ventilation fan. s must be switched out of circuit during a fire scenario. For efficiency ratings and grades please refer to our Fan Selector for more information. conditions. These are presented for comparative purposes only.

40 4 3PH 2ºC/2HRS HT JM - 9MM - 6 BLADES 4 POLE HT9JM/25/4/6/2 12 HT9JM/25/4/6/26 13 HT9JM/25/4/6/ m3/hr HT9JM/25/4/6/ HT9JM/25/4/6/ HT9JM/25/4/6/ Unique rev/min Phase Motor (kw) 11 HT9JM/25/4/6/2 AJHL-2-14-XX M (IE2) CD2417 IDDXF HT9JM/25/4/6/26 AJHL-2-15-XX L112M (IE2) CD2417 IDDXF HT9JM/25/4/6/32 AJHL-2-16-XX M (IE2) CD2417 IDDXF Note - XX in Unique denotes impeller pitch angle, which must be a value between the P/A and s can be used for Dual Mode High Temperature fans when fan is operating as a standard ventilation fan. s must be switched out of circuit during a fire scenario. For efficiency ratings and grades please refer to our Fan Selector for more information. conditions. These are presented for comparative purposes only.

41 41 3PH 2ºC/2HRS HT JM - 9MM - 9 BLADES 4 POLE HT9JM/25/4/9/18 15 HT9JM/25/4/9/ m3/hr HT9JM/25/4/9/ HT9JM/25/4/9/ Unique rev/min Phase Motor (kw) 14 HT9JM/25/4/9/18 AJHL-2-17-XX L112M (IE2) CD2417 IDDXF HT9JM/25/4/9/24 AJHL-2-18-XX M (IE2) CD2417 IDDXF Note - XX in Unique denotes impeller pitch angle, which must be a value between the P/A and s can be used for Dual Mode High Temperature fans when fan is operating as a standard ventilation fan. s must be switched out of circuit during a fire scenario. For efficiency ratings and grades please refer to our Fan Selector for more information. conditions. These are presented for comparative purposes only.

42 42 3PH 2ºC/2HRS HT JM - 1MM - 25MM HUB 4 POLE HT1JM/25/4/6/22 17 HT1JM/25/4/9/ m3/hr HT1JM/25/4/6/ HT1JM/25/4/9/ Unique rev/min Phase Motor (kw) 16 HT1JM/25/4/6/22 AJHL-2-19-XX M (IE2) CD2417 IDDXF HT1JM/25/4/9/14 AJHL-2-2-XX M (IE2) CD2417 IDDXF Note - XX in Unique denotes impeller pitch angle, which must be a value between the P/A and s can be used for Dual Mode High Temperature fans when fan is operating as a standard ventilation fan. s must be switched out of circuit during a fire scenario. For efficiency ratings and grades please refer to our Fan Selector for more information. conditions. These are presented for comparative purposes only.

43 43 3PH 2ºC/2HRS HT JM - 1MM - 315MM HUB 4 POLE HT1JM/31/4/9/ HT1JM/31/4/9/22 11 HT1JM/31/4/9/ HT1JM/31/4/9/ m3/hr HT1JM/31/4/9/ HT1JM/31/4/9/ HT1JM/31/4/9/ HT1JM/31/4/9/ Unique rev/min Phase Motor (kw) 18 HT1JM/31/4/9/14 AJHL-2-21-XX M (IE2) CD2417 IDDXF HT1JM/31/4/9/22 AJHL-2-22-XX M (IE2) CD2417 IDDXF HT1JM/31/4/9/28 AJHL-2-23-XX L (IE2) CD2417 IDDXF HT1JM/31/4/9/36 AJHL-2-24-XX L (IE2) CD2417 IDDXF Note - XX in Unique denotes impeller pitch angle, which must be a value between the P/A and s can be used for Dual Mode High Temperature fans when fan is operating as a standard ventilation fan. s must be switched out of circuit during a fire scenario. For efficiency ratings and grades please refer to our Fan Selector for more information. conditions. These are presented for comparative purposes only.

44 44 3ºC QUICK SELECTION CHARTS 12 Express Build - 3ph HT3º C/2hrs Smoke Venting fans 2 pole 315mm to 63mm Range Overview - Quick Fan diameter selection m3/hr Express Build - 3ph HT3º C/2hrs Smoke Venting fans 4 pole 4mm to 63mm Range Overview - Quick Fan diameter selection m3/hr

45 1 45 3ºC QUICK SELECTION CHARTS 8 Express Build - 3ph HT3 º C/2hrs Smoke Venting fans 4 pole 71mm to 1mm Range Overview - Quick Fan diameter selection

46 46 3PH 3ºC/2HRS HT JMv - 315MM, 355MM & 4MM 2 POLE HT4JMv/16/2/6/ HT31JMv/14/2/6/ HT35JMv/14/2/6/3 124 HT4JMv/16/2/6/ HT4JMv/16/2/6/ HT35JMv/14/2/6/ m3/hr HT31JMv/14/2/6/ HT35JMv/14/2/6/ HT35JMv/14/2/6/ HT4JMv/16/2/6/ HT4JMv/16/2/6/ HT4JMv/16/2/6/ Unique rev/min Phase Motor (kw) 12 HT31JMv/14/2/6/36 AVHL-3-1-XX (IE3) CD2416 IDDXF HT35JMv/14/2/6/3 AVHL-3-2-XX (IE2) CD2416 IDDXF HT35JMv/14/2/6/4 AVHL-3-3-XX (IE2) CD2416 IDDXF HT4JMv/16/2/6/14 AVHL-3-4-XX (IE2) CD2416 IDDXF HT4JMv/16/2/6/22 AVHL-3-5-XX (IE2) CD2416 IDDXF HT4JMv/16/2/6/29 AVHL-3-6-XX (IE2) CD2416 IDDXF Note - XX in Unique denotes impeller pitch angle, which must be a value between the P/A and s can be used for Dual Mode High Temperature fans when fan is operating as a standard ventilation fan. s must be switched out of circuit during a fire scenario. For efficiency ratings and grades please refer to our Fan Selector for more information. conditions. These are presented for comparative purposes only.

47 47 3PH 3ºC/2HRS HT JMv - 45MM & 5MM 2 POLE HT5JMv/2/2/6/ HT45JMv/16/2/6/ HT45JMv/16/2/6/ HT45JMv/16/2/6/17 13 HT5JMv/2/2/6/3 131 HT5JMv/2/2/6/ m3/hr HT45JMv/16/2/6/ HT45JMv/16/2/6/ HT45JMv/16/2/6/ HT5JMv/2/2/6/ HT5JMv/2/2/6/ HT5JMv/2/2/6/ Unique rev/min Phase Motor (kw) 126 HT45JMv/16/2/6/13 AVHL-3-7-XX (IE2) CD2416 IDDXF HT45JMv/16/2/6/17 AVHL-3-8-XX (IE2) CD2416 IDDXF HT45JMv/16/2/6/32 AVHL-3-9-XX L9L (IE2) CD2416 IDDXF HT5JMv/2/2/6/24 AVHL-3-1-XX M (IE2) CD2417 IDDXF HT5JMv/2/2/6/3 AVHL-3-11-XX M (IE2) CD2417 IDDXF HT5JMv/2/2/6/38 AVHL-3-12-XX M (IE2) CD2416 IDDXF Note - XX in Unique denotes impeller pitch angle, which must be a value between the P/A and s can be used for Dual Mode High Temperature fans when fan is operating as a standard ventilation fan. s must be switched out of circuit during a fire scenario. For efficiency ratings and grades please refer to our Fan Selector for more information. conditions. These are presented for comparative purposes only.

48 48 3PH 3ºC/2HRS HT JMv / JM - 56MM & 63MM 2 POLE HT56JMv/2/2/6/ HT56JMv/2/2/6/ HT56JMv/2/2/6/ HT63JM/25/2/3/ m3/hr HT56JMv/2/2/6/ HT56JMv/2/2/6/ HT56JMv/2/2/6/ * 135 HT63JM/25/2/3/ Unique rev/min Phase Motor (kw) 132 HT56JMv/2/2/6/12 AVHL-3-13-XX M (IE2) CD2417 IDDXF HT56JMv/2/2/6/17 AVHL-3-14-XX M (IE2) CD2417 IDDXF HT56JMv/2/2/6/23 AVHL-3-15-XX M (IE2) CD2416 IDDXF * 135 HT63JM/25/2/3/28 AJHL-3-1-XX M (IE2) CD2416 IDDXF * Fan available soon Note - XX in Unique denotes impeller pitch angle, which must be a value between the P/A and s can be used for Dual Mode High Temperature fans when fan is operating as a standard ventilation fan. s must be switched out of circuit during a fire scenario. For efficiency ratings and grades please refer to our Fan Selector for more information. conditions. These are presented for comparative purposes only.

49 49 3PH 3ºC/2HRS HT JMv 4MM - 63MM 4 POLE HT5JMv/2/4/6/ HT45JMv/16/4/6/ HT5JMv/2/4/6/ HT63JMv/2/4/6/ HT63JMv/2/4/6/24 14 HT56JMv/2/4/6/ HT4JMv/16/4/6/ m3/hr HT4JMv/16/4/6/ HT45JMv/16/4/6/ HT5JMv/2/4/6/ HT5JMv/2/4/6/ HT56JMv/2/4/6/ HT63JMv/2/4/6/ HT63JMv/2/4/6/ Unique rev/min Phase Motor (kw) 136 HT4JMv/16/4/6/4 AVHL-3-16-XX (IE2) CD2416 IDDXF HT45JMv/16/4/6/35 AVHL-3-17-XX (IE2) CD2416 IDDXF HT5JMv/2/4/6/26 AVHL-3-18-XX (IE2) CD2416 IDDXF HT5JMv/2/4/6/34 AVHL-3-19-XX (IE2) CD2416 IDDXF HT56JMv/2/4/6/35 AVHL-3-2-XX L (IE2) CD2416 IDDXF HT63JMv/2/4/6/24 AVHL-3-21-XX L (IE2) CD2416 IDDXF HT63JMv/2/4/6/35 AVHL-3-22-XX L (IE2) CD2416 IDDXF Note - XX in Unique denotes impeller pitch angle, which must be a value between the P/A and s can be used for Dual Mode High Temperature fans when fan is operating as a standard ventilation fan. s must be switched out of circuit during a fire scenario. For efficiency ratings and grades please refer to our Fan Selector for more information. conditions. These are presented for comparative purposes only.

50 5 3PH 3ºC/2HRS HT JM - 71MM 2MM HUB 4 POLE HT71JM/2/4/6/3 151 HT71JM/2/4/6/ m3/hr HT71JM/2/4/6/ HT71JM/2/4/6/ Unique rev/min Phase Motor (kw) 15 HT71JM/2/4/6/3 AJHL-3-2-XX L (IE2) CD2416 IDDXF HT71JM/2/4/6/36 AJHL-3-3-XX M (IE2) CD2417 IDDXF Note - XX in Unique denotes impeller pitch angle, which must be a value between the P/A and s can be used for Dual Mode High Temperature fans when fan is operating as a standard ventilation fan. s must be switched out of circuit during a fire scenario. For efficiency ratings and grades please refer to our Fan Selector for more information. conditions. These are presented for comparative purposes only.

51 51 3PH 3ºC/2HRS HT JM - 71MM 25MM HUB 4 POLE HT71JM/25/4/9/ HT71JM/25/4/6/ HT71JM/25/4/9/ HT71JM/25/4/9/ m3/hr HT71JM/25/4/6/ HT71JM/25/4/9/ HT71JM/25/4/9/ HT71JM/25/4/9/ Unique rev/min Phase Motor (kw) 152 HT71JM/25/4/6/34 AJHL-3-4-XX L (IE2) CD2416 IDDXF HT71JM/25/4/9/28 AJHL-3-5-XX L (IE2) CD2416 IDDXF HT71JM/25/4/9/34 AJHL-3-6-XX M (IE2) CD2417 IDDXF HT71JM/25/4/9/36 AJHL-3-7-XX L112M (IE2) CD2417 IDDXF Note - XX in Unique denotes impeller pitch angle, which must be a value between the P/A and s can be used for Dual Mode High Temperature fans when fan is operating as a standard ventilation fan. s must be switched out of circuit during a fire scenario. For efficiency ratings and grades please refer to our Fan Selector for more information. conditions. These are presented for comparative purposes only

52 52 3PH 3ºC/2HRS HT JM - 8MM 2MM HUB 4 POLE HT8JM/2/4/6/ HT8JM/2/4/6/ HT8JM/2/4/6/ m3/hr HT8JM/2/4/6/ HT8JM/2/4/6/ HT8JM/2/4/6/ Unique rev/min Phase Motor (kw) 156 HT8JM/2/4/6/18 AJHL-3-8-XX L (IE2) CD2416 IDDXF HT8JM/2/4/6/24 AJHL-3-9-XX M (IE2) CD2417 IDDXF HT8JM/2/4/6/32 AJHL-3-1-XX L112M (IE2) CD2417 IDDXF Note - XX in Unique denotes impeller pitch angle, which must be a value between the P/A and s can be used for Dual Mode High Temperature fans when fan is operating as a standard ventilation fan. s must be switched out of circuit during a fire scenario. For efficiency ratings and grades please refer to our Fan Selector for more information. conditions. These are presented for comparative purposes only

53 53 3PH 3ºC/2HRS HT JM - 8MM 25MM HUB 4 POLE 5 16 HT8JM/25/4/9/ HT8JM/25/4/9/ HT8JM/25/4/6/ HT8JM/25/4/9/ HT8JM/25/4/9/ m3/hr HT8JM/25/4/6/ HT8JM/25/4/9/ HT8JM/25/4/9/ HT8JM/25/4/9/ HT8JM/25/4/9/ Unique rev/min Phase Motor (kw) 159 HT8JM/25/4/6/36 AJHL-3-11-XX L112M (IE2) CD2417 IDDXF HT8JM/25/4/9/18 AJHL-3-12-XX L (IE2) CD2416 IDDXF HT8JM/25/4/9/22 AJHL-3-13-XX M (IE2) CD2417 IDDXF HT8JM/25/4/9/28 AJHL-3-14-XX L112M (IE2) CD2417 IDDXF HT8JM/25/4/9/36 AJHL-3-15-XX M (IE2) CD2417 IDDXF Note - XX in Unique denotes impeller pitch angle, which must be a value between the P/A and s can be used for Dual Mode High Temperature fans when fan is operating as a standard ventilation fan. s must be switched out of circuit during a fire scenario. For efficiency ratings and grades please refer to our Fan Selector for more information. conditions. These are presented for comparative purposes only

54 54 3PH 3ºC/2HRS HT JM - 9MM 25MM HUB 4 POLE HT9JM/25/4/9/ HT9JM/25/4/9/ HT9JM/25/4/9/ m3/hr HT9JM/25/4/9/ HT9JM/25/4/9/ HT9JM/25/4/9/ Unique rev/min Phase Motor (kw) 164 HT9JM/25/4/9/18 AJHL-3-16-XX M (IE2) CD2417 IDDXF HT9JM/25/4/9/24 AJHL-3-17-XX M (IE2) CD2417 IDDXF HT9JM/25/4/9/32 AJHL-3-18-XX M (IE2) CD2417 IDDXF Note - XX in Unique denotes impeller pitch angle, which must be a value between the P/A and s can be used for Dual Mode High Temperature fans when fan is operating as a standard ventilation fan. s must be switched out of circuit during a fire scenario. For efficiency ratings and grades please refer to our Fan Selector for more information. conditions. These are presented for comparative purposes only

55 55 3PH 3ºC/2HRS HT JM - 1MM 25MM HUB 4 POLE HT1JM/25/4/9/ HT1JM/25/4/9/2 169 HT1JM/25/4/9/ m3/hr HT1JM/25/4/9/ HT1JM/25/4/9/ HT1JM/25/4/9/ Unique rev/min Phase Motor (kw) 167 HT1JM/25/4/9/14 AJHL-3-19-XX M (IE2) CD2417 IDDXF HT1JM/25/4/9/2 AJHL-3-2-XX M (IE2) CD2417 IDDXF HT1JM/25/4/9/28 AJHL-3-21-XX L (IE2) CD2417 IDDXF Note - XX in Unique denotes impeller pitch angle, which must be a value between the P/A and s can be used for Dual Mode High Temperature fans when fan is operating as a standard ventilation fan. s must be switched out of circuit during a fire scenario. For efficiency ratings and grades please refer to our Fan Selector for more information. conditions. These are presented for comparative purposes only

56 56 3PH 3ºC/2HRS HT JM - 1MM 315MM HUB 4 POLE HT1JM/31/4/9/ HT1JM/31/4/9/2 172 HT1JM/31/4/9/ HT1JM/31/4/9/ m3/hr HT1JM/31/4/9/ HT1JM/31/4/9/ HT1JM/31/4/9/ HT1JM/31/4/9/ Unique rev/min Phase Motor (kw) 17 HT1JM/31/4/9/14 AJHL-3-22-XX M (IE2) CD2417 IDDXF HT1JM/31/4/9/2 AJHL-3-23-XX M (IE2) CD2417 IDDXF HT1JM/31/4/9/28 AJHL-3-24-XX L (IE2) CD2417 IDDXF HT1JM/31/4/9/36 AJHL-3-25-XX L (IE2) CD2417 IDDXF Note - XX in Unique denotes impeller pitch angle, which must be a value between the P/A and s can be used for Dual Mode High Temperature fans when fan is operating as a standard ventilation fan. s must be switched out of circuit during a fire scenario. For efficiency ratings and grades please refer to our Fan Selector for more information. conditions. These are presented for comparative purposes only

57 57 4ºC QUICK SELECTION CHARTS Express Build - 3ph HT4º C/2hrs Smoke Venting fans 2 pole 315mm to 4mm Range Overview - Quick Fan diameter selection m3/hr Express Build - 3ph HT4º C/2hrs Smoke Venting fans 4 pole 4mm to 63mm Range Overview - Quick Fan diameter selection m3/hr

58 1 58 4ºC QUICK SELECTION CHARTS 8 Express Build - 3ph HT4ºC/2hrs Smoke Venting fans 4 pole 71mm to 1mm Range Overview - Quick Fan diameter selection m3/hr

59 59 3PH 4ºC/2HRS HT JMv - 315MM - 4MM 2 POLE HT4JMv/16/2/6/ HT31JMv/14/2/6/ HT35JMv/14/2/6/3 184 HT4JMv/16/2/6/ HT35JMv/14/2/6/ m3/hr HT31JMv/14/2/6/ HT35JMv/14/2/6/ HT35JMv/14/2/6/ HT4JMv/16/2/6/ HT4JMv/16/2/6/ Unique rev/min Phase Motor (kw) 18 HT31JMv/14/2/6/36 AVHL-4-1-XX (IE3) CD2416 IDDXF HT35JMv/14/2/6/3 AVHL-4-2-XX (IE2) CD2416 IDDXF HT35JMv/14/2/6/4 AVHL-4-3-XX (IE2) CD2416 IDDXF HT4JMv/16/2/6/14 AVHL-4-4-XX (IE2) CD2416 IDDXF HT4JMv/16/2/6/29 AVHL-4-5-XX (IE2) CD2416 IDDXF Note - XX in Unique denotes impeller pitch angle, which must be a value between the P/A and s can be used for Dual Mode High Temperature fans when fan is operating as a standard ventilation fan. s must be switched out of circuit during a fire scenario. For efficiency ratings and grades please refer to our Fan Selector for more information. conditions. These are presented for comparative purposes only.

60 6 3PH 4ºC/2HRS HT JMv - 4MM - 63MM 4 POLE HT63JMv/2/4/6/ HT5JMv/2/4/6/34 19 HT63JMv/2/4/6/ HT56JMv/2/4/6/ HT5JMv/2/4/6/ HT4JMv/16/4/6/4 186 HT45JMv/16/4/6/ m3/hr HT4JMv/16/4/6/ HT45JMv/16/4/6/ HT5JMv/2/4/6/ HT5JMv/2/4/6/ HT56JMv/2/4/6/ HT63JMv/2/4/6/ HT63JMv/2/4/6/ Unique rev/min Phase Motor (kw) 185 HT4JMv/16/4/6/4 AVHL-4-6-XX (IE2) CD2416 IDDXF HT45JMv/16/4/6/35 AVHL-4-7-XX (IE2) CD2416 IDDXF HT5JMv/2/4/6/34 AVHL-4-8-XX (IE2) CD2416 IDDXF HT5JMv/2/4/6/4 AVHL-4-9-XX (IE2) CD2416 IDDXF HT56JMv/2/4/6/35 AVHL-4-1-XX L (IE2) CD2416 IDDXF HT63JMv/2/4/6/24 AVHL-4-11-XX L (IE2) CD2416 IDDXF HT63JMv/2/4/6/33 AVHL-4-12-XX L (IE2) CD2416 IDDXF Note - XX in Unique denotes impeller pitch angle, which must be a value between the P/A and s can be used for Dual Mode High Temperature fans when fan is operating as a standard ventilation fan. s must be switched out of circuit during a fire scenario. For efficiency ratings and grades please refer to our Fan Selector for more information. conditions. These are presented for comparative purposes only. *3 phase only.

61 61 3PH 4ºC/2HRS HT JM - 71MM 4 POLE HT71JM/25/4/6/28 21 HT71JM/25/4/6/ HT71JM/25/4/6/ m3/hr HT71JM/25/4/6/ HT71JM/25/4/6/ HT71JM/25/4/6/ Unique rev/min Phase Motor (kw) 2 HT71JM/25/4/6/28 AJHL-4-1-XX L (IE2) CD2416 IDDXF HT71JM/25/4/6/34 AJHL-4-2-XX L (IE2) CD2416 IDDXF HT71JM/25/4/6/36 AJHL-4-3-XX M (IE2) CD2417 IDDXF Note - XX in Unique denotes impeller pitch angle, which must be a value between the P/A and s can be used for Dual Mode High Temperature fans when fan is operating as a standard ventilation fan. s must be switched out of circuit during a fire scenario. For efficiency ratings and grades please refer to our Fan Selector for more information. conditions. These are presented for comparative purposes only.

62 62 3PH 4ºC/2HRS HT JM - 8MM 2MM HUB, 3 & 6 BLADES 4 POLE HT8JM/2/4/6/ HT8JM/2/4/6/24 23 HT8JM/2/4/3/ HT8JM/2/4/3/ m3/hr HT8JM/2/4/3/ HT8JM/2/4/3/ HT8JM/2/4/6/ HT8JM/2/4/6/ Unique rev/min Phase Motor (kw) 23 HT8JM/2/4/3/3 AJHL-4-4-XX L (IE2) CD2416 IDDXF HT8JM/2/4/3/36 AJHL-4-5-XX M (IE2) CD2417 IDDXF HT8JM/2/4/6/18 AJHL-4-6-XX L (IE2) CD2416 IDDXF HT8JM/2/4/6/24 AJHL-4-7-XX M (IE2) CD2417 IDDXF Note - XX in Unique denotes impeller pitch angle, which must be a value between the P/A and s can be used for Dual Mode High Temperature fans when fan is operating as a standard ventilation fan. s must be switched out of circuit during a fire scenario. For efficiency ratings and grades please refer to our Fan Selector for more information. conditions. These are presented for comparative purposes only.

63 63 3PH 4ºC/2HRS HT JM - 8MM 25MM HUB, 6 BLADES 4 POLE HT8M/25/4/6/ HT8M/25/4/6/24 29 HT8M/25/4/6/28 21 HT8M/25/4/6/ m3/hr HT8JM/25/4/6/ HT8JM/2/4/6/ HT8JM/25/4/6/ HT8JM/25/4/6/ Unique rev/min Phase Motor (kw) 27 HT8M/25/4/6/18 AJHL-4-8-XX L (IE2) CD2416 IDDXF HT8M/25/4/6/24 AJHL-4-9-XX L (IE2) CD2416 IDDXF HT8M/25/4/6/28 AJHL-4-1-XX M (IE2) CD2417 IDDXF HT8M/25/4/6/36 AJHL-4-11-XX S (IE2) CD2417 IDDXF Note - XX in Unique denotes impeller pitch angle, which must be a value between the P/A and s can be used for Dual Mode High Temperature fans when fan is operating as a standard ventilation fan. s must be switched out of circuit during a fire scenario. For efficiency ratings and grades please refer to our Fan Selector for more information. conditions. These are presented for comparative purposes only.

64 64 3PH 4ºC/2HRS HT JM - 8MM 25MM HUB, 9 BLADES 4 POLE HT8M/25/4/9/ HT8M/25/4/9/ m3/hr HT8JM/25/4/9/ HT8JM/25/4/9/ Unique rev/min Phase Motor (kw) 211 HT8M/25/4/9/28 AJHL-4-12-XX S (IE2) CD2417 IDDXF HT8M/25/4/9/36 AJHL-4-13-XX M (IE2) CD2417 IDDXF Note - XX in Unique denotes impeller pitch angle, which must be a value between the P/A and s can be used for Dual Mode High Temperature fans when fan is operating as a standard ventilation fan. s must be switched out of circuit during a fire scenario. For efficiency ratings and grades please refer to our Fan Selector for more information. conditions. These are presented for comparative purposes only.

65 65 3PH 4ºC/2HRS HT JM - 9MM 4 POLE HT9JM/25/4/9/ HT9JM/25/4/9/ HT9JM/25/4/6/ HT9JM/25/4/6/2 218 HT9JM/25/4/9/ HT9JM/25/4/6/ m3/hr HT9JM/25/4/6/ HT9JM/25/4/6/ HT9JM/25/4/6/ HT9JM/25/4/9/ HT9JM/25/4/9/ HT9JM/25/4/9/ Unique rev/min Phase Motor (kw) 213 HT9JM/25/4/6/2 AJHL-4-14-XX M (IE2) CD2417 IDDXF HT9JM/25/4/6/26 AJHL-4-15-XX S (IE2) CD2417 IDDXF HT9JM/25/4/6/32 AJHL-4-16-XX M (IE2) CD2417 IDDXF HT9JM/25/4/9/18 AJHL-4-17-XX S (IE2) CD2417 IDDXF HT9JM/25/4/9/24 AJHL-4-18-XX M (IE2) CD2417 IDDXF HT9JM/25/4/9/28 AJHL-4-19-XX M (IE2) CD2417 IDDXF Note - XX in Unique denotes impeller pitch angle, which must be a value between the P/A and s can be used for Dual Mode High Temperature fans when fan is operating as a standard ventilation fan. s must be switched out of circuit during a fire scenario. For efficiency ratings and grades please refer to our Fan Selector for more information. conditions. These are presented for comparative purposes only.

66 66 3PH 4ºC/2HRS HT JM - 1MM 4 POLE HT1JM/31/4/6/ HT1JM/31/4/9/ HT1JM/31/4/9/ HT1JM/31/4/6/26 22 HT1JM/31/4/6/ m3/hr HT1JM/31/4/6/ HT1JM/31/4/6/ HT1JM/31/4/6/ HT1JM/31/4/6/ HT1JM/31/4/6/ Unique rev/min Phase Motor (kw) 219 HT1JM/31/4/6/16 AJHL-4-2-XX S (IE2) CD2417 IDDXF HT1JM/31/4/6/22 AJHL-4-21-XX M (IE2) CD2417 IDDXF HT1JM/31/4/6/26 AJHL-4-22-XX M (IE2) CD2417 IDDXF HT1JM/31/4/9/28 AJHL-4-23-XX L (IE2) CD2417 IDDXF HT1JM/31/4/9/36 AJHL-4-24-XX L (IE2) CD2417 IDDXF Note - XX in Unique denotes impeller pitch angle, which must be a value between the P/A and s can be used for Dual Mode High Temperature fans when fan is operating as a standard ventilation fan. s must be switched out of circuit during a fire scenario. For efficiency ratings and grades please refer to our Fan Selector for more information. conditions. These are presented for comparative purposes only.

67 67 IDDXF54 HVAC INVERTER THREE PHASE IP54 DEMAND INDEPENDENT, SWITCHED AND PROPORTIONAL DRIVE FOR AXIAL AND CENTRIFUGAL FANS FEATURES 4V, A,.75-9kW 3 Ph Designed for HVAC applications i.e. Fire mode, Flying Start Enclosures IP54 (see IDDXF2 for IP2 and IDDXF66 for IP66) Asynch and PM motor control. shielded cable length 25m Simple installation wizard. Alpha-numeric display In built motor overheat protection via motor thermistors EMC A1/C2 integrated filters and DC choke for harmonic mitigation 4xDI, 2xAI, 1xAO/DO and 2xRO / RS485. Modbus RTU, N2, FLN and BACnet imum ambient 5 C OPTIONAL ACCESSORIES PIR Temp Sensor CO 2 Sensor Pressure Sensor -1 V pot - (1 volt) DESCRIPTION Designed specifically for three phase fan applications our IDDXF Frequency converters control speed, torque, and the overall performance of AC and PM motors by controlling the power input. Independent, Switched and Proportional demand control from the included digital, and HVAC protocols ensures maximum efficiency and comfort to the level required. A safety isolator/switch disconnector should be installed on the mains side of all motor drives; refer to our SISO product within our controls publication. When using an inverter with a dual mode fan which is capable of delivering both a normal ventilation and HT smoke extraction functions, the inverter must be switched out of circuit during a fire scenario. The mechanism for doing this is however not part of our supply. RANGE Model Ph. V IP Amps kw FWG Part Enc. IDDXF V EA9116 I2 IDDXF V EA9117 I2 Description Local Panel Local Panel mounting kit inc. 3m cable Decoupling plate H1 & H2 Decoupling plate H3 Decoupling plate H4 & H5 IP21 option H1 IP21 option H2 IP21 option H3 IP21 option H4 IP21 option H5 FWG Part EA9131 EA9132 EA9133 EA9134 EA9135 EA9136 EA9137 EA9138 EA9139 EA914 Please note: If running in hand (manual) mode a external link is required between 12 and 27. If running in auto mode a external link is required between 12 and 18. WIRING DIAGRAM For detail please refer to the specific diagrams supplied with each drive. IDDXF V EA9118 I2 IDDXF V EA9119 I2 IDDXF V EA912 I2 1 - Line IDDXF V EA9121 I3 IDDXF V EA9122 I3 IDDXF V EA9123 I4 IDDXF V EA9124 I4 IDDXF V EA9125 I4 2 1 MAINS Motor Earth 3 - Motor 4 - Relay IDDXF V EA9126 I6 IDDXF V EA9127 I6 2 U V W -DC+DC IDDXF V EA9128 I6 IDDXF V EA9129 I7 3 IDDXF V EA9169 I7 IDDXF V EA917 I8 IDDXF V EA9171 I8

68 68 DIMENSIONS AND WEIGHTS B b ø See diagram below COMPATIBILITY Please refer to the specific instructions & software supplied with each drive. C a A All works may only be carried out by skilled personnel following the local regulations, reference to the installation guide and AFTER the controller is completely isolated from the mains. e e f f d a a e e Enclosure Power [kw] Height [mm] Width [mm] Depth [mm] Mounting hole [mm] Weight IP Frame Class 3x V A A incl Decoupling Plate a B b C d e f kg I2 IP I3 IP I4 IP I5 IP I6 IP I7 IP I8 IP

69 69 WIRING DIAGRAMS CD2416 THREE PHASE JM STAR CONNECTION U1 V1 W1 INCOMING MOTOR LEADS TO MATCH TERMINAL BLOCK LETTERING. K K U1 V1 W1 V2 U2 W2 K K U V W ADDITIONAL CIRCUITS WHEN FITTED: THERMAL PROTECTION SS - THERMISTOR KK - THERMOSTAT L1 L2 L3 THREE PHASE SUPPLY TO REVERSE ROTATION SWAP ANY 2 INCOMING PHASES PE EARTH TO TERMINAL BODY CASE CD2417 THREE PHASE JM DELTA CONNECTION INCOMING MOTOR LEADS TO MATCH TERMINAL BLOCK LETTERING. K K U1 V1 W1 V2 U2 W2 K K U V W All dimensions in mm. ADDITIONAL CIRCUITS WHEN FITTED: THERMAL PROTECTION SS - THERMISTOR KK - THERMOSTAT L1 L2 L3 THREE PHASE SUPPLY TO REVERSE ROTATION SWAP ANY 2 INCOMING PHASES FOR USE ON STAR/DELTA PACK REMOVE LINKS PE EARTH TO TERMINAL BODY CASE

70 7 WIRING DIAGRAMS CD32 CONNECTION DIAGRAM FOR THREE PHASE DELTA FIXED SPEED USING 7 OR 1 CORE CABLE ROTATION IS ACDE FOR JMv (AS SHOWN) USE CDE ROTATION FOR JM* (L2) (L1) (L3) V U W STERN TERMINATES TO BOX CASING PE ADDITIONAL CIRCUITS WHEN FITTED: THERMAL PROTECTION SS- THERMISTOREN KK - THERMOKONTAKT U1 V1 W1 V2 U2 W2 BRAUN SCHWARZ GRAU WEISS ROT BLAU MOTOREINGANGSLEITUNGEN PASSEND ZU KLEMMENBLOCK CD318 CONNECTION DIAGRAM FOR THREE PHASE DUAL VOLTAGE, STAR ROTATION IS ACDE FOR JMv (AS SHOWN) USE CDE ROTATION FOR JM* V (L2) U (L1) W (L3) DELTA TERMINATES TO BOX CASING PE ADDITIONAL CIRCUITS WHEN FITTED: THERMAL PROTECTION SS- THERMISTOR KK - THERMOSTAT U1 V1 W1 V2 U2 W2 BROWN BLACK GREY WHITE RED BLUE INCOMING MOTOR LEADS TO MATCH TERMINAL BLOCK LETTERING * TO REVERSE ROTATION SWAP ANY 2 INCOMING PHASES

71 71 DRAWINGS JM AEROFOIL JMv AEROFOIL E C A M NO. OF HOLES N DIA. EQUISPACED ON F PCD (EACH END) AIRFLOW FORM B (Only) B DIA. OVER FLANGES A DIA. INSIDE K DIA HOLES IN FOOT L D G CRS A All dimensions in mm. H CRS J

72 72 DRAWING DIMENSIONS - 5ºC FANS Model Motor Frame Motor KW A B C D E F G H J K L M N Weight (kg) 1 31JMv/14/2/6/33 BT9 (IE1) JMv/14/2/6/3 8 (IE2) JMv/14/2/6/4 8 (IE2) JMv/16/2/6/14 8 (IE2) JMv/16/2/6/22 8 (IE2) JMv/16/2/6/29 8 (IE2) JMv/16/2/6/17 8 (IE2) JMv/16/2/6/32 L9L (IE2) JMv/16/2/6/19 L9L (IE2) JMv/2/2/6/3 112M (IE2) JMv/2/2/6/39 L112M (IE2) JMv/2/2/6/17 112M (IE2) JMv/2/2/6/24 L112M (IE2) JM/25/2/3/22 112M (IE2) JM/25/2/3/28 L112M (IE2) JMv/14/4/6/4 BT4 (IE1) JMv/14/4/6/8 BT4 (IE1) JMv/16/4/6/4 8 (IE2) JMv/16/4/6/35 8 (IE2) JMv/2/4/6/34 8 (IE2) JMv/2/4/6/35 9L (IE2) JMv/2/4/6/24 9L (IE2) JMv/2/4/6/33 1L (IE2) JM/2/4/6/22 1L (IE2) JM/2/4/6/3 1L (IE2) JM/2/4/6/36 112M (IE2) JM/25/4/9/2 1L (IE2) JM/25/4/9/28 1L (IE2) JM/25/4/9/34 112M (IE2) JM/2/4/6/18 1L (IE2) JM/2/4/6/24 112M (IE2) JM/25/4/9/22 112M (IE2) JM/25/4/9/28 L112M (IE2) JM/25/4/9/36 132M (IE2) JM/25/4/6/2 112M (IE2) JM/25/4/6/26 L112M (IE2) JM/25/4/6/32 132M (IE2) JM/25/4/9/18 L112M (IE2) JM/25/4/9/24 132M (IE2) JM/25/4/6/22 132M (IE2) JM/25/4/9/14 132M (IE2) JM/31/4/9/14 132M (IE2) JM/31/4/9/22 16M (IE2) JM/31/4/9/28 16L (IE2) JM/31/4/9/36 18L (IE2) All dimensions in mm.

73 73 DRAWING DIMENSIONS - 2ºC FANS Model Motor Frame Motor KW A B C D E F G H J K L M N Weight (kg) 6 HT4JMv/16/2/6/14 8 (IE2) HT4JMv/16/2/6/22 8 (IE2) HT4JMv/16/2/6/29 8 (IE2) HT45JMv/16/2/6/17 8 (IE2) HT45JMv/16/2/6/32 L9L (IE2) HT5JMv/16/2/6/19 L9L (IE2) HT56JMv/2/2/6/17 112M (IE2) HT63JM/25/2/3/22 112M (IE2) HT63JM/25/2/3/28 L112M (IE2) HT4JMv/16/4/6/4 8 (IE2) HT45JMv/16/4/6/35 8 (IE2) HT5JMv/2/4/6/34 8 (IE2) HT56JMv/2/4/6/35 9L (IE2) HT63JMv/2/4/6/24 9L (IE2) HT63JMv/2/4/6/33 1L (IE2) HT71JM/2/4/6/22 1L (IE2) HT71JM/2/4/6/3 1L (IE2) HT71JM/2/4/6/36 112M (IE2) HT71JM/25/4/9/2 1L (IE2) HT71JM/25/4/9/28 1L (IE2) HT71JM/25/4/9/34 112M (IE2) HT8JM/2/4/6/18 1L (IE2) HT8JM/2/4/6/24 112M (IE2) HT8JM/25/4/9/22 112M (IE2) HT8JM/25/4/9/28 132S (IE2) HT8JM/25/4/9/36 132M (IE2) HT9JM/25/4/6/2 112M (IE2) HT9JM/25/4/6/26 132S (IE2) HT9JM/25/4/6/32 132M (IE2) HT9JM/25/4/9/18 132S (IE2) HT9JM/25/4/9/24 132M (IE2) HT1JM/25/4/6/22 132M (IE2) HT1JM/25/4/9/14 132M (IE2) HT1JM/31/4/9/14 132M (IE2) HT1JM/31/4/9/22 16M (IE2) HT1JM/31/4/9/28 16L (IE2) HT1JM/31/4/9/36 18L (IE2) All dimensions in mm.

74 74 DRAWING DIMENSIONS - 3ºC FANS Model Motor Frame Motor KW A B C D E F G H J K L M N Weight (kg) 12 HT31JMv/14/2/6/36 8 (IE3) HT35JMv/14/2/6/3 8 (IE2) HT35JMv/14/2/6/4 8 (IE2) HT4JMv/16/2/6/14 8 (IE2) HT4JMv/16/2/6/22 8 (IE2) HT4JMv/16/2/6/29 8 (IE2) HT45JMv/16/2/6/13 8 (IE2) HT45JMv/16/2/6/17 8 (IE2) HT45JMv/16/2/6/32 L9L (IE2) HT5JMv/2/2/6/24 112M (IE2) HT5JMv/2/2/6/3 112M (IE2) HT5JMv/2/2/6/38 112M (IE2) HT56JMv/2/2/6/12 112M (IE2) HT56JMv/2/2/6/17 112M (IE2) HT56JMv/2/2/6/23 112M (IE2) HT63JM/25/2/3/28 112M (IE2) HT4JMv/16/4/6/4 8 (IE2) HT45JMv/16/4/6/35 8 (IE2) HT5JMv/2/4/6/26 8 (IE2) HT5JMv/2/4/6/34 8 (IE2) HT56JMv/2/4/6/35 9L (IE2) HT63JMv/2/4/6/24 9L (IE2) HT63JMv/2/4/6/35 1L (IE2) HT71JM/2/4/6/3 1L (IE2) HT71JM/2/4/6/36 112M (IE2) HT71JM/25/4/6/34 1L (IE2) HT71JM/25/4/9/28 1L (IE2) HT71JM/25/4/9/34 112M (IE2) HT71JM/25/4/9/36 L112M (IE2) HT8JM/2/4/6/18 1L (IE2) HT8JM/2/4/6/24 112M (IE2) HT8JM/2/4/6/32 L112M (IE2) HT8JM/25/4/6/36 L112M (IE2) HT8JM/25/4/9/18 1L (IE2) HT8JM/25/4/9/22 112M (IE2) HT8JM/25/4/9/28 L112M (IE2) HT8JM/25/4/9/36 132M (IE2) HT9JM/25/4/9/18 112M (IE2) HT9JM/25/4/9/24 132M (IE2) HT9JM/25/4/9/32 132M (IE2) HT1JM/25/4/9/14 132M (IE2) HT1JM/25/4/9/2 132M (IE2) HT1JM/25/4/9/28 16L (IE2) HT1JM/31/4/9/14 132M (IE2) HT1JM/31/4/9/2 132M (IE2) HT1JM/31/4/9/28 16L (IE2) HT1JM/31/4/9/36 18L (IE2) All dimensions in mm.

75 75 DRAWING DIMENSIONS - 4ºC FANS Model Motor Frame Motor KW A B C D E F G H J K L M N Weight (kg) 18 HT31JMv/14/2/6/36 8 (IE3) HT35JMv/14/2/6/3 8 (IE2) HT35JMv/14/2/6/4 8 (IE2) HT4JMv/16/2/6/14 8 (IE2) HT4JMv/16/2/6/29 8 (IE2) HT4JMv/16/4/6/4 8 (IE2) HT45JMv/16/4/6/35 8 (IE2) HT5JMv/2/4/6/34 8 (IE2) HT5JMv/2/4/6/4 8 (IE2) HT56JMv/2/4/6/35 9L (IE2) HT63JMv/2/4/6/24 9L (IE2) HT63JMv/2/4/6/33 1L (IE2) HT71JM/25/4/6/28 1L (IE2) HT71JM/25/4/6/34 1L (IE2) HT71JM/25/4/6/36 112M (IE2) HT8JM/2/4/3/3 1L (IE2) HT8JM/2/4/3/36 112M (IE2) HT8JM/2/4/6/18 1L (IE2) HT8JM/2/4/6/24 112M (IE2) HT8M/25/4/6/18 1L (IE2) HT8M/25/4/6/24 1L (IE2) HT8M/25/4/6/28 112M (IE2) HT8M/25/4/6/36 132S (IE2) HT8M/25/4/9/28 132S (IE2) HT8M/25/4/9/36 132M (IE2) HT9JM/25/4/6/2 112M (IE2) HT9JM/25/4/6/26 132S (IE2) HT9JM/25/4/6/32 132M (IE2) HT9JM/25/4/9/18 132S (IE2) HT9JM/25/4/9/24 132M (IE2) HT9JM/25/4/9/28 132M (IE2) HT1JM/31/4/6/16 132S (IE2) HT1JM/31/4/6/22 132M (IE2) HT1JM/31/4/6/26 132M (IE2) HT1JM/31/4/9/28 16L (IE2) HT1JM/31/4/9/36 18L (IE2) All dimensions in mm.

76 P G 76 CASED & PLATE AXIAL - ACCESSORIES JM/JMv MATCHING FLANGE AND FLEXIBLE CONNECTOR C Suitable for fan ØA Number Flexible Matching Flange Connector C Weight (kg) Flexible Matching Flange Connector AS AS AS AS AS AS AS AS AS HOLES TO MATCH FAN FLANGE AS AS JM/JMv MOUNTING FEET (SET OF 2) Note: Flexible connection weight includes two matching flanges. Suitable for up to 4 C emergency operation for 2 hours and 2 C continuous. Motor Frame Number G L M N P T V W AS AS AS AS AS AS Weight Kg 63 1 AS AS T DIA HOLES 4 HOLES N DIA AS AS AS AS AS AS L CRS M The AS product numbers shown consist of a set of 2 mounting feet. JM/JMv DAMPER Suitable for fan ØA Number C D Weight (kg) Note: Suitable for up to 4 C emergency operation and 2 C continuous. not stocked, available in 3 working weeks. D MAX C ØA All dimensions in mm. HOLES TO MATCH FAN FLANGE See Note 1

77 77 CASED - ACCESSORIES JM/JMv BELLMOUTH INLET - FAN WITH FLANGED INLET ONLY ØD Suitable for fan ØA See Note 1 D ØA Number C C Ø D HOLES TO MATCH FAN FLANGE Weight (kg) JM/JMv GUARD Number See Note 1 Description 31JM/JMP Guard Impeller (L) 35JM/JMP Guard Impeller (L) 4JM/JMP Guard Impeller (L) 45JM/JMP Guard Impeller (L) 5JM/JMP Guard Impeller (L) 56JM/JMP Guard Impeller Side (L) 63JM Guard Impeller Side (L) 71JM Guard Impeller Side (L) 8JM Guard Impeller Side (L) 9JM Guard Impeller Side (L) 1JM Guard impeller Side (L) 31JM Guard Bellmouth and M/side (L) 35JM Guard Bellmouth and M/side (L) 4JM Guard Bellmouth and M/side (L) 45JM Guard Bellmouth and M/side (L) 5JM Guard Bellmouth and M/side (L) 56JM Guard Bellmouth and M/side (L) 63JM Guard Bellmouth and M/side (L) 71JM Guard Bellmouth and M/side (L) 8JM Guard Bellmouth and M/side (L) 9JM Guard Bellmouth and M/side (L) 1JM Guard Bellmouth and M/side (L) Motor Frame Dim C Weight Kg BT/CT BT/CT BT/CT BT/CT BT/CT N/A N/A N/A N/A N/A N/A N/A 3.5 N/A 3.5 N/A 3.6 N/A 3.6 N/A 3.7 N/A 5 1 N/A N/A N/A N/A N/A 5 2 C C Impeller Side L Type Bellmouth and L Type Motor Side All dimensions in mm. Note 1: Air operated dampers, bellmouth inlets & guards are not stocked items so are available on a slightly longer leadtime (3-4 weeks)

78 78 CASED - ACCESSORIES SILENCER POD (C TYPE ONLY) øb øa C DRILLING TO MATCH FAN FLANGES WITH THREAD SIZE J B TYPE SILENCER C TYPE SILENCER (PODDED) Bore Dia. mm Number B C J Weight (kg) Bore Dia. mm Number B C J Weight (kg) 315 SB M SB M SB M SB M1 2 5 SB M SB M SB M SB M SB M SB M SB M SC M SC M SC M SC M SC M SC M SC M SC M SC M SC M SC M12 1 Bore Dia. mm B Type dba Reduction C Type to to to to to to to to to to -15 The above silencers give the following approximate dba reductions: B Type 1 diameter length - 7 to -1 dba. C Type 1 diameter length - 12 to -15 dba. For full acoustic details and resistance to airflow for type C see publications SP1. Note: Silencers are not stocked items so are available on a slightly longer leadtime (3-4 Weeks) to to to to to to to to to to to to to to to to to to to to to to to to to to to to to to to to to to -15 All dimensions in mm.

79 79 CASED ACCESSORIES RUBBER IN SHEAR ANTI-VIBRATION MOUNTS G A E F C D B Type Load at 5-6mm deflection (Kg) A B C D E F G 55 AV Rubber MP2-28 Yellow ISL M8 551 AV Rubber MP2-5 Blue ISL M8 552 AV Rubber MP2-8 Red ISL M8 E A 6 C D Ø11 A Type Load at 5-6 mm deflection (Kg) A B C D E 553 AV Rubber MP1-45 White ISL M AV Rubber MP1-65 Red ISL M AV Rubber MP1-75 Yellow ISL M AV Rubber MP1-55 Blue ISL M12 All dimensions in mm. Note: Rubber mounts may also be used for fans rated 2 C for 2hours.

80 A E H 8 CASED ACCESSORIES ENCLOSED SPRING ANTI-VIBRATION MOUNTS F D G B C Type Load at 2mm deflection (Kg) A B C D E F G H 559 MMS1-L-1 Claret ISL M MMS1-L-15 Yellow ISL M MMS1-L-2 Grey ISL M MMS1-L-4 Green ISL M MMS1-L-7 Red ISL M MMS1-L-1 Blue ISL M Type Load at 25mm deflection (Kg) A B C D E F G H 5515 MMS1-3 Yellow ISL M MMS1-6 Green ISL M MMS1-1 Blue ISL M MMS1-16 White ISL M MMS1-25 Red ISL M Note: Spring mounts are recommended for use with HT (High Temperature) smoke extract fans, rated 2 C for 2hours, 3 C for 2hours or 4 C for 2hours. Anti-Vibration Selection Notes When selecting anti-vibration mounts, please add all the weights for associated accessories to the fan weight then divide the total weight by 4 to obtain the per mount requirement. Select an anti-vibration mount with a weight rating that is at least the same, but ideally greater than the per mount requirement weight. If in doubt, please seek assistance from our sales team.

81 81 USEFUL INFORMATION INSTALLATION ADVICE - HORIZONTAL MOUNTING Fig. 1H. A fan at entry should be connected to the ducting with a flexible connector and vibration isolators should be used. Fig. 2H. A fan within ducting should be connected by flexible connectors at each end mounted on vibration isolators. Vibration Isolators Fig. 3H. For a two-stage fan it is usually necessary to fit vibration isolators at the middle joint as well as at each end. Here 4 sets are shown as smaller fans only 3 sets may be necessary. To avoid mechanically transmitted sound and vibration problems fans are normally installed on vibration isolators. Fig. 4H. The arrangement of flexible connectors and vibration isolators for a single stage fan with one cylindrical silencer. Note: 'B' type silencers must be bolted directly to the fans. Silencer Fig. 5H. The vibration isolator arrangements for a single stage fan with a silencer each end. Silencer (B Type only) Silencer Silencer Fig. 6H. The vibration isolator arrangement for a two stage fan with a silencer at each end. Silencer (B Type only) Silencer Silencer 3D 1D Silencer D Silencer 1.5D Fig. 7H. Fans in parallel should blow into a common plenum chamber. The minimum dimensions of the plenum chamber in relation to the fan dia should be as above. Silencer (B Type only)

82 82 USEFUL INFORMATION INSTALLATION ADVICE - VERTICAL MOUNTING Make sure the support does not restrict access for removal. Silencer Fig. 1V. Support a single stage fan by mounting feet or plates fixed to the upper flange. Fig. 2V. For a two stage fan support at the upper and lower flanges. Fig. 3V. For a single stage fan with silencer below, support at the top of the fan and top of the silencer. Silencer Silencer Silencer Silencer Silencer Silencer Silencer Fig. 4V. The support arrangement for a two stage fan with a silencer below. Fig. 5V. The supports for a single stage fan with a silencer above. Fig. 6V. Supports for a two stage fan with a silencer above. Fig. 7V. Supports for a single stage fan with a silencer above and below. Fig. 8V. Supports for a two stage fan with a silencer above and below. Silencer (B Type only) Silencer (B Type only)

83 83 USEFUL INFORMATION INSTALLATION ADVICE - BENDS, EXPANDERS AND CONTRACTORS (TRANSFORMATION PIECES) WRONG Fan performance suffers and noise is increased if a 9 circular section bend of small radius is used. (starves half the impeller) RECOMMENDED Use a square bend with short chord turning vanes. This is also preferable when air flow is in the opposite direction. α α D WRONG Do not use an expander of more than 15 immediately before or after the fan. (This starves the blades) RECOMMENDED Ideally an expander immediately before a fan should not be more than 15. Flexible connections WRONG Flexible connectors should not be slack, as this will cause "necking", which will starve the impeller blade tips of air, reduce fan performance and increase noise. (starves the blades) RECOMMENDED Flexible connectors should be just long enough for mechanical isolation and should be taut.

84 84 USEFUL INFORMATION INSTALLATION ADVICE - INLET AND OUTLETS Make sure the support does not restrict access for removal. Silencer Fig. 1V. Support a single stage fan by mounting feet or plates fixed to the upper flange. Fig. 2V. For a two stage fan support at the upper and lower flanges. Fig. 3V. For a single stage fan with silencer below, support at the top of the fan and top of the silencer. Silencer Silencer Silencer Silencer Silencer Silencer Silencer g. 4V. The support rrangement for a two age fan with a lencer below. Fig. 5V. The supports for a single stage fan with a silencer above. Fig. 6V. Supports for a two stage fan with a silencer above. Fig. 7V. Supports for a single stage fan with a silencer above and below. Fig. 8V. Supports for a two stage fan with a silencer above and below. Silencer (B Type only) Silencer (B Type only)

85 85 USEFUL INFORMATION AIR CHANGES PER HOUR Although no hard and fast rules can be laid down for rates of air changes, the recommendations in the table below may be taken as a general guide. Situation Air Changes per hour Assembly Halls 4-6 Bakeries 15-3 Banks 2-4 Bathrooms 6-8 Bars 6-8 Boiler Houses 15-3 Cafés 8-12 Canteens 8-12 Churches 1-1 Cinemas* 6-1 Classrooms 2-4 Cleaners 15-3 Dance Halls 8-12 Domestic Kitchens 1-15 Dyers 15-3 Engine Rooms 15-3 Foundries 3-6 Furnace Rooms 3-6 Garages 6-1 Hospital Wards 6-8 Hospital Treatment Rooms 6-8 Kitchens for Restaurants 13-3 Laboratories 4-6 Laundries 1-15 Libraries 2-4 Offices 4-6 Paint Shops 3-6 Residences 1-2 Restaurants* 1-15 Storage Areas 1-2 Swimming Baths 15-3 Theatres* 6-1 Workshops 6-1 in x 25.4 = mm ft x.35 = m ft 3 x.28 = m 3 Ib x.454 = kg BTU x = J HP x.746 = kw k cal/h x.116 = kw Ton rigeration x 3.52 = kw BTU/ft 2 h F x = J/m 2 s C or = W/m2 C ft 3 /min x.472 = m 3 /s in. wg x = Pa * General requirements are 28m 3 /h per person minimum in public places; more if smoking is allowed. Dependent on height of building and number of persons. FUME REMOVAL Recommended minimum velocities across face of extract hood: Sandblast Booths 2.5m/s openings Sandblast Booths.4m/s downwards through booth Electro-Plating.75-1.m/s openings Electric Welding.5-1.m/s Paint Spray Booths.75m/s in breathing zone Kitchen Equipment.5-.75m/s

86 86 USEFUL INFORMATION CONVERSION MOTOR ENCLOSURES DEGREES OF PROTECTION 1st Numeral 2nd Numeral Designation Protection against contact and ingress of foreign bodies. Protection against water. IP44 Protection against contact with live or moving parts of tools, Water splashed against the motor from any wires or other objects of thickness greater than 1 mm. direction shall have no harmful effect. Protection against the ingress of solid foreign bodies with a diameter greater than 1mm. IP55 Complete protection against contact with live or moving parts Water projected by nozzle against the motor inside the enclosure. Protection against harmful deposits of dust. from any direction shall have no harmful effect. The ingress of dust is not totally prevented, but dust cannot enter in an amount sufficient to interfere with satisfactory operation IP55 as despatched. Drain holes are incorporated of the machine. such that by removing the appropriate plugs all-weather protection can be provided and condensation build-up prevented. IP56 Motor protected against conditions on a ship s deck. IP66 Protected from total dust ingress Protected from high pressure water jets from any direction.

87 87 NOTES...

88 ExpressBuild Catalogue 9855 GB Copyright 216 Fläkt Woods Limited WE BRING BETTER AIR TO LIFE EXPRESS BUILD CATALOGUE 9855 GB With over a century of innovation and expertise to share with our customers, Fläkt Woods is a global leader in Air Technology products and solutions. We specialise in the design and manufacturing of a wide range of products and solutions for Air Movement, Air Treatment, Air Distribution, Air Management and Air Diffusion with focus on two major benefits Air Comfort and Fire Safety. With market presence in 65 countries we are in a unique position to be a local supplier and an international partner in our customer s projects. Our product brands such as SEMCO, eq, eq Prime, JM Aerofoil, JMv Aerofoil, VCC technology, Econet, Veloduct, Optivent, Optimix, Econovent and Cleanvent are well-known and trusted by customers all over the world to deliver high quality and energy efficient solutions.» To learn more about our offering and get in contact with your nearest sales representative please visit AIR MOVEMENT - FANS CENTRE OF EXCELLENCE Axial Way, Colchester, Essex. CO4 5ZD Tel: +44 ()

Section 4. Axial Fans - Section 4

Section 4. Axial Fans - Section 4 Axial Flow Fans Section 4 Fläkt Woods offers a wide range of axial flow fans for general air movement and special applications such as emergency high temperature smoke extract and pressurisation. ATEX

More information

CASED 24 Designed for emergency ventilation of hot fire smoke applications 300 C or 400 C for two hours operation, CE marked to EN12101-3 2002 All casings are hot dipped galvanised Sizes from 315mm to

More information

400mm - 630mm diameter Volume flow up to 7.2m 3 /s ASED 42 Static pressures up to 1000 Pa High energy efficiency All casings are hot dipped galvanised Low installed noise levels protection IP55 Overheat

More information

MAXFAN COMPAC » OFFERING HIGH PERFORMANCE, ROBUST DESIGN AND FLEXIBLE CONTROL AIR COMFORT FIRE SAFETY AIR MOVEMENT

MAXFAN COMPAC » OFFERING HIGH PERFORMANCE, ROBUST DESIGN AND FLEXIBLE CONTROL AIR COMFORT FIRE SAFETY AIR MOVEMENT AIR COMFORT FIRE SAFETY AIR MOVEMENT MAXFAN COMPAC» OFFERING HIGH PERFORMANCE, ROBUST DESIGN AND FLEXIBLE CONTROL INTRODUCING THE MAXFAN COMPAC THE NEW MAXFAN COMPAC DESIGNED FOR THE KITCHEN CANOPY MARKET

More information

Section 4 e c tio - P lat F a n s

Section 4 e c tio - P lat F a n s Plate Fans Section 4 The Fläkt Woods Plate Fan Range is the result of detailed market analysis and intensive research and development by the world leaders in air movement technology. By setting and achieving

More information

JM Aerofoil Multi-Stage 50 Hz

JM Aerofoil Multi-Stage 50 Hz JM Aerofoil Multi-Stage 5 Hz JM AEROFOIL - MULTI-STAGE CONTENTS Page: JM Aerofoil Multi-Stage - Introduction -5 Multi-Staging Motor Frame Size Schedules - Three Phase 7-8 Performance Curves SK1- SK135

More information

DATASHEET 63JMP/20/4/3/32

DATASHEET 63JMP/20/4/3/32 62 ATE HMIDITY FAS SESOR JM STB-02 ATE FA DATASHEET RODCT FACTS Air flow up to 8.17 m 3 /s Static pressures up to 260 a Motor protection I55 Speed controllable Supplied fully assembled Full range of accessories

More information

Axial fans. What s more, non-stock models are normally available within two weeks.

Axial fans. What s more, non-stock models are normally available within two weeks. Axial fans 7 sees the introduction of a new production line at Xpelair s Peterborough plant for the Scimitar Sickle blade fans in Plate, Short Case and Roof versions up to 63mm. Scimitar will join an impressive

More information

Duct mounted fans. axial flow. Pacific HVAC Engineering Tel. Australia NZ

Duct mounted fans. axial flow. Pacific HVAC Engineering Tel. Australia NZ Duct mounted fans axial flow Pacific HVAC Engineering 215 www.pacifichvac.com Tel. Australia 13 733 833 NZ 8 1 326 6 5 4 3 2 1 5 1 15 2 7 6 5 4 3 2 1 3 2.5 2 1.5 1.5 1 15.5 1 1.5 2 2.5 3 3.5 Volume m 3

More information

Explanation of AR Series Ventilator Products. Fan type code D S AR AE

Explanation of AR Series Ventilator Products. Fan type code D S AR AE Series Axial Fan Explanation of Series Ventilator Products Fan type code 450-7 /26 D -2 F400 Smoke Extract Fan 400 C, 300 C Number of Poles D S Three Phase Single Phase AE AE Features and construction

More information

MAJAX-2 GENERAL SPECIFICATION

MAJAX-2 GENERAL SPECIFICATION MAJAX-2 GENERAL SPECIFICATION Majax-2 axial flow fans are manufactured in diameters ranging from 315mm to 2000mm (available in 2250mm on request), and incorporate manually adjustable pitch aluminium bladed

More information

Wide performance ranges are obtained by using three impeller designs to suit all types of applications.

Wide performance ranges are obtained by using three impeller designs to suit all types of applications. Roof Mounted Fans Section 6 Wide performance ranges are obtained by using three impeller designs to suit all types of applications. The roof extract units are designed to satisfy the consultants functional

More information

CYLINDRICAL CASED AXIAL FLOW FANS TGT Series - ADJUSTABLE PITCH FANS

CYLINDRICAL CASED AXIAL FLOW FANS TGT Series - ADJUSTABLE PITCH FANS - ADJUSTABLE PITCH FANS Range of adjustable pitch aerofoil blade, cased axial flow fans. Casings formed from rolled sheet steel with a corrosion resistant hot dip galvanised finish. All models incorporate

More information

CYLINDRICAL CASED AXIAL FLOW FANS

CYLINDRICAL CASED AXIAL FLOW FANS - Adjustable pitch fans Range of adjustable pitch aerofoil blade, cased axial flow fans. Casings formed from rolled sheet steel with a corrosion resistant hot dipped galvanised finish. All models incorporate

More information

Max. airflow m 3 /s Diam. min. Diam. max

Max. airflow m 3 /s Diam. min. Diam. max Axial Fans Max. airflow m 3 /s Diam. min Diam. max 1% adjustable motor Assembly, any position Reversible (3% Reduction) Page Number AW AR AW.97 2 3 * * 13 AR.97 2 3 * * 134 ZSP 2.9 315 5 * * 13 ZAP 13.89

More information

CASED AXIAL BIFURCATED SERIES 33

CASED AXIAL BIFURCATED SERIES 33 76 CASED AXIA BIFURCATED SERIES 33 PRODUCT FACTS Air flow up to 0.95 m 3 /s Static pressures up to 380 Pa Suitable for temperatures up to 200 C Series 33 is cost effective solution to Bifurcated applications

More information

JM Aerofoil Bifurcated Fans

JM Aerofoil Bifurcated Fans JM Aerofoil Bifurcated Fans JM AEROFOIL - BIFURCATED CONTENTS The Bifurcated Fan Range - Introduction 3 Applications 4 Specification 5 Forms of Running, Test Methods & Quality Systems 6 Guide To Fan Selection

More information

ErP PLASTIC TUBE FANS - ESPADA FEATURES. ELECTRICAL SUPPLY V/50Hz/1f SIZES TEMPERATURE RANGE FEATURES AND CONSTRUCTION PRODUCT CODE

ErP PLASTIC TUBE FANS - ESPADA FEATURES. ELECTRICAL SUPPLY V/50Hz/1f SIZES TEMPERATURE RANGE FEATURES AND CONSTRUCTION PRODUCT CODE 83 PLASTIC TUBE FANS - ESPADA FEATURES mm to 315 mm diameter Air flow up to.35 m 3 /s Static pressures up to 58 Pa Plastic cased centrifugal fan Low noise levels Corrosion resistant design Easy electrical

More information

Short casing. Long casing (L version) Commercial premises

Short casing. Long casing (L version) Commercial premises CYLINDRICAL CASED AXIAL FLOW FANS TGT Series Adjustable Pitch Fans Long casing (L version) Short casing A P P L I C A T I O N S Range of adjustable pitch cased axial flow fans. Casings formed from rolled

More information

Roof Units. Specification. Construction. Performance. Impellers. Size range. Ancillary Equipment

Roof Units. Specification. Construction. Performance. Impellers. Size range. Ancillary Equipment Roof Extract Units Roof Units Specification The Flaktwoods Colchester range of roof extract units are designed to satisfy the consultants functional requirement for a direct drive fan unit of guaranteed

More information

S ACON SEACON SEACO QUIPMEN EQUIPMENTS SEACON EQUIPMENTS

S ACON SEACON SEACO QUIPMEN EQUIPMENTS SEACON EQUIPMENTS S ACON EQ NTS ACON E NTS A S EQ A TS TS TS TS TS E AC AC AC AC AC AC S S UIP IPME IPME QU P QUI QUI EQ EQUI Q EQ EQ EQ EQ EN EN SE SE SEAC AC AC AC AC AC AC ACO EQUIP E MEN SEACO EQUIPMEN A EQU EQU AC

More information

ROOFMASTER STEF-HT ROOF FAN

ROOFMASTER STEF-HT ROOF FAN fire safety Air movement Roof Fans ROOFMASTER STEF-HT ROOF FAN» Technical CATALOGuE Contents ROOFMASTER STEF-HT...3 Performance Data...4 Performance Table...5 General description...6 Fan Chart-explanation

More information

ROOFMASTER STEF-HT ROOF FAN

ROOFMASTER STEF-HT ROOF FAN fire safety Air movement Roof Fans ROOFMASTER STEF-HT ROOF FAN» Technical CATALOGuE Contents ROOFMASTER STEF-HT...3 Performance Data...4 Performance Table...5 General description...6 Fan Chart-explanation

More information

Hison Axial Flow Fans

Hison Axial Flow Fans Hison Axial Flow Fans Introduction Hison Marine Axial Flow Fans, formerly know as Howden Fans are manufactured to international Quality Standard. Axial flow fans are available from sizes 35mm to 18mm diameter,

More information

Size and Configurations

Size and Configurations !!"#!""!"$%!!" &'()&('& AK Axial Flow Fans the high efficiency direct-driven fan with adjustable pitch impeller specially designed to operate with low noise emission and vibration that meets the stringent

More information

BIFLOW SB CON Product Brochure

BIFLOW SB CON Product Brochure BIFLOW SB CON Brochure Available for next day delivery with ELTA SELECT Bifurcated Conical Axial Flow Fan For full detailed information on the following: Sound Data, Accessories & Wiring Data and Optimum

More information

Hison Axial Flow Fans

Hison Axial Flow Fans Hison Axial Flow Fans Introduction Hison Marine Axial Flow Fans, formerly know as Howden Fans are manufactured to international Quality Standard. Axial flow fans are available from sizes 35mm to 18mm diameter,

More information

TGT Series Adjustable Pitch Fans

TGT Series Adjustable Pitch Fans CYLINDRICAL CASED AXIAL FLOW FANS Series Adjustable Pitch Fans Range of adjustable pitch aerofoil blade, cased axial flow fans.casings formed from rolled sheet steel with a corrosion resistant hot dipped

More information

CONTENTS. Page. Adjustable Axial Pitch Flow Fans 3. Dimensions 4. AP056 Performance Curves 5. AP056 Sound Performance 6. AP063 Performance Curves 7

CONTENTS. Page. Adjustable Axial Pitch Flow Fans 3. Dimensions 4. AP056 Performance Curves 5. AP056 Sound Performance 6. AP063 Performance Curves 7 CONTENTS Page Adjustable Axial Pitch Flow Fans 3 Dimensions 4 AP056 Performance Curves 5 AP056 Sound Performance 6 AP063 Performance Curves 7 AP063 Sound Performance 8 AP071Performance Curves 9 AP071 Sound

More information

ErP METAL TUBE FANS - ROPERA EC FEATURES ELECTRICAL SUPPLY TEMPERATURE RANGE SIZES FEATURES AND CONSTRUCTION PRODUCT CODE INSTALLATION

ErP METAL TUBE FANS - ROPERA EC FEATURES ELECTRICAL SUPPLY TEMPERATURE RANGE SIZES FEATURES AND CONSTRUCTION PRODUCT CODE INSTALLATION 95 METAL TUBE FANS - ROPERA EC FEATURES mm to 355 mm diameter Air flow up to.56 m 3 /s Static pressures up to 7 Pa Casing - galvanized sheet steel Backward curved impeller Easy electrical connection via

More information

TGT Series Adjustable Pitch Fans

TGT Series Adjustable Pitch Fans CYLINDRICAL CASED AXIAL FLOW FANS TGT Series Adjustable Pitch Fans Range of adjustable pitch aerofoil blade, cased axial flow fans.casings formed from rolled sheet steel with a corrosion resistant hot

More information

HIGH TEMPERATURE TWIN SQUIF FANS

HIGH TEMPERATURE TWIN SQUIF FANS HIGH TEMPERATURE FANS HIGH TEMPERATURE FOR SMOKE EXTRACT CERTIFIED TO EN12101-3-2002. 374 029 2085 8200 BENEFITS QUIET AND POWERFUL SOLUTIONS High performance centrifugal motor/impeller combination providing

More information

supplied in Form (B) configuration. Airflow over Impeller- Motor.

supplied in Form (B) configuration. Airflow over Impeller- Motor. CYLINDRICAL CASED AXIAL FLOW FANS COMPACT Series TCBB-TCBT (Aluminium impellers) and TCFB-TCFT (Plastic impellers) NEW VERSIONS Description The S&P Cylindrical Cased Axial Fans feature, as the name suggests,

More information

ErP POWERBOX EC FANS - ESTOC EC FEATURES ELECTRICAL SUPPLY TEMPERATURE RANGE SIZES FEATURES AND CONSTRUCTION PRODUCT CODE IMPELLER MOTOR

ErP POWERBOX EC FANS - ESTOC EC FEATURES ELECTRICAL SUPPLY TEMPERATURE RANGE SIZES FEATURES AND CONSTRUCTION PRODUCT CODE IMPELLER MOTOR 13 POWERBOX EC FANS - ESTOC EC FEATURES Sizes from 3 to 3 mm diameter Air flow up to.1 m 3 /s Static pressures up to Pa Controllable EC motors Multiple outlet orientations ELECTRICAL SUPPLY 22-2V/Hz/1f

More information

CONTRA ROTATING CASED AXIAL FANS TCBBx2 / TCBTx2 Series

CONTRA ROTATING CASED AXIAL FANS TCBBx2 / TCBTx2 Series Range of cylindrical cased axial fans fitted with aluminium impellers and manufactured from high grade rolled galvanised steel and protected against corrosion by cataforesis primer and black polyester

More information

Sabre Plate Mounted Sickle Fans (VSP)

Sabre Plate Mounted Sickle Fans (VSP) Sabre Plate Mounted Sickle Fans (VSP) Swept impeller with Aerofoil blades, winglets and serrated trailing edge for optimum performance One shot die cast impeller, dynamically balanced for smoother operation

More information

CASED & PLATE AXIAL - ACCESSORIES

CASED & PLATE AXIAL - ACCESSORIES P G 77 ASE & PLATE AXIAL - AESSORIES JM MATHING FLANGE AN FLEXIBLE ONNETOR fan ØA Flexible Matching Flange onnector Flexible Matching Flange onnector 315 A408238 AS040315 110 1.1 3.3 355 A501351 AS040355

More information

Centrifugal performance characteristics with axial flow pattern: RADAX VAR

Centrifugal performance characteristics with axial flow pattern: RADAX VAR High pressure in-line mixed-flow fans RADAX VAR Centrifugal performance characteristics with axial flow pattern: RADAX VAR COMPACT PRESSURE-RESISTANT UNIVERSAL In their compact casing, the RADAX VAR impellers

More information

NEW GENERATION SERIES

NEW GENERATION SERIES FEATURES The New Generation Series of axial roof units are fitted with adjustable pitch impellers enabling a wide performance range to be obtained from any one unit. Construction Galvanised steel base,

More information

Bifurcated Case Axial Fans (BIFA)

Bifurcated Case Axial Fans (BIFA) Bifurcated Case Axial Fans (BIFA) Sizes 250 to 1000 dia Motors protected to IP55 Motor insulation Class F Maximum ambient temperature 200 C Speed controllable via transformer or inverter (when the ambient

More information

CGT Series Adjustable Pitch Fans

CGT Series Adjustable Pitch Fans AXIAL FLOW CABINET FAN CGT Series Adjustable Pitch Fans New Ø 400-450-500 Range of adjustable pitch aerofoil blade, axial flow cabinet fans.fan casing manufactured from heavy gauge galvanised sheet steel

More information

AXIAL FANS Catalogue CN0050C01 May 2008

AXIAL FANS Catalogue CN0050C01 May 2008 ADTA AXIAL FANS Catalogue CN0050C01 May 2008 ADTA AXIAL FANS Catalogue CN0050C01 May 2008 Construction Specifications Impellers: Breezax aerfoil blades are available in four types of material: Glass Reinforced

More information

AC Commercial Fans Edition. ErP ready

AC Commercial Fans Edition. ErP ready AC Commercial Fans 213 Edition ErP ready AC Commercial Fans Axair Fans UK Ltd / 1782 34943 About Axair Fans UK Axair is an independent industrial fan manufacturer and distributor. What we offer : Application

More information

CGT Series Adjustable Pitch Fans

CGT Series Adjustable Pitch Fans AXIAL FLOW CABINET FAN CGT Series Adjustable Pitch Fans New Ø 400-450-500 Range of adjustable pitch aerofoil blade, axial flow cabinet fans.fan casing manufactured from heavy gauge galvanised sheet steel

More information

Circular Box Fans - DAISHO EC Range DAISHO EC 125. Features. Electrical Supply. Product Code. Sizes 125, 150, 200, 250, 315, 450, 630 and 1000.

Circular Box Fans - DAISHO EC Range DAISHO EC 125. Features. Electrical Supply. Product Code. Sizes 125, 150, 200, 250, 315, 450, 630 and 1000. Circular Box Fans - DAISHO EC Range Features 125mm to 1mm Air flow 1,25 m 3 /h (3.5m 3 /s) Static pressures up to 125 Pa Maximum temperature range 6ºC Suitable for variable or constant pressure systems

More information

Series TDA DIRECT DRIVEN MODEL: TDA- 450/9AA/8-8/ / Construction. Airflow Direction

Series TDA DIRECT DRIVEN MODEL: TDA- 450/9AA/8-8/ / Construction. Airflow Direction DIRECT DRIVEN Series TDA Construction Double flanged casing is produced in mild steel or galvanised steel, available in short and long cased. The impeller having manually adjustable pitch blades is made

More information

AXICIAT VA. Axial fans. Smoke extraction F200/120 and F400/120. High available pressure

AXICIAT VA. Axial fans. Smoke extraction F200/120 and F400/120. High available pressure Smoke extraction F200/120 and F400/120 A complete range from 1250 to 95000 m 3 /s High available pressure Blade with variable pitch on stop APPLICATION Extraction or introduction of non-loaded air in the

More information

SECTION AXIAL HVAC FANS

SECTION AXIAL HVAC FANS SECTION 233413 - AXIAL HVAC FANS 1. PART 1 GENERAL 1.1. RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

200mm - 760mm diameter Volume flow up to 9.2m 3 /s Static pressures up to 1000 Pa Four fan types allowing versatility of performance Rugged fibre glass construction casings Completely assembled units Mounting

More information

ROOFMASTER STEF-ATEX ROOF FAN

ROOFMASTER STEF-ATEX ROOF FAN Air Comfort Air movement Roof fans ROOFMASTER STEF-ATEX ROOF FAN» Technical CATALOGuE 2 STEF-ATEX Roofmaster - Technical Catalogue Contents General description Application/specification... 3 Features...

More information

REVOLUTION SLCX Product Brochure

REVOLUTION SLCX Product Brochure REVOLUTION SLCX Brochure Available for next day delivery with ELTA SELECT ATEX Long Cased Axial Flow Fan For full detailed information on the following: Sound Data, Accessories & Wiring Data and Optimum

More information

Novenco axial flow fans. ZerAx - Standard January 2010

Novenco axial flow fans. ZerAx - Standard January 2010 Novenco axial flow fans ZerAx - Standard January 2010 Product facts Product The Novenco ZerAx series of axial flow fans uses innovative design to reduce power consumption by improving efficiency. As an

More information

ROOF MOUNTED AXIAL FLOW FANS HCTB / HCTT Series

ROOF MOUNTED AXIAL FLOW FANS HCTB / HCTT Series asy to install Supports to facilitate installation in the roof. XTRACTION (type B) SUPPLY (type A) High quality steel sleeve nsuring the long life of the fan. Range of axial roof fans with horizontal air

More information

EXHAUST FANS CUD & CUB UPBLAST FANS

EXHAUST FANS CUD & CUB UPBLAST FANS EXHAUST FANS CUD & CUB UPBLAST FANS Suitable for roof or wall mount Backward inclined, non overloading wheels Spun aluminum housing Blades & inlets fabricated from aluminum Easy access to motor compartment

More information

Short casing. Long casing (L version) Highly versatile range due to different number of available blades and adjustable pitch angles

Short casing. Long casing (L version) Highly versatile range due to different number of available blades and adjustable pitch angles CYLINDRICAL CASED AXIAL FLOW FANS TGT Series Additional Information Standard air direction: form (B) configuration (Impeller over ). models description: incorporated an "L" after blade pitch angle. E.g.

More information

Transformer Oil Cooling Solutions

Transformer Oil Cooling Solutions pumps and fans Transformer Oil Cooling Solutions Series NTG/ TG/ TGCL Pumps TF/ TFBR/ NTF/ VTTF Fans quality certificate INDEX The company Portfolio Development PUMPS Nomenclature Inline axial pumps NTG

More information

Sabre Sickle Fan Assisted Roof Cowls (VSR)

Sabre Sickle Fan Assisted Roof Cowls (VSR) Sabre Sickle Fan Assisted Roof Cowls (VSR) Swept impeller with Aerofoil blades, winglets and serrated trailing edge for optimum performance Fully assembled cowl, separate plate axial fan Optional backdraught

More information

Tube Fans - ESPADA Range ESPADA 100 (L) Features. Electrical Supply. Product Code. Sizes 100, 125, 150, 160, 200, 250 and 315

Tube Fans - ESPADA Range ESPADA 100 (L) Features. Electrical Supply. Product Code. Sizes 100, 125, 150, 160, 200, 250 and 315 Tube Fans - ESPADA Range Features mm to 315 mm diameter Air flow 18 m 3 /h (.5 m 3 /s) Static pressures up to 72 Pa Plastic cased centriugal fan Low noise levels Completely corrosion resistant Easy electrical

More information

CHMT Series, F Rated Fans

CHMT Series, F Rated Fans CNTRIFUGAL SINGL INLT FANS CT Series, F400 120 Rated Fans Officially approved to N12101-3 standard (certificate number 0370-CPD-0348) Range of single inlet direct drive centrifugal fans designed for smoke

More information

NOVENCO FAN CATALOGUE

NOVENCO FAN CATALOGUE NOVENCO FAN CATALOGUE WWW.NOVENCO-MARINE.COM ZERAX AXIAL FLOW FANS PRODUCT The Novenco ZerAx series of axial flow fans use innovative design to reduce power consumption and to better fan efficiency. The

More information

IN-LINE DUCT FANS MIXVENT-TD Fan Systems

IN-LINE DUCT FANS MIXVENT-TD Fan Systems IN-LINE DUCT FANS MIXVENT-TD Fan Systems NEW TD-EXTRACTOR KIT (see page 175) MIXVENT TD / MIXVENT TD-T MIXVENT TDx2 ACCESSORIES Description Range Construction The MIXVENT system has been designed to compliment

More information

THT/HATCH THT/HATCH. Order code THT/HATCH 40 2T 1 N 1 G

THT/HATCH THT/HATCH. Order code THT/HATCH 40 2T 1 N 1 G THT/HATCH High-powered ventilators with motorised opening and equipped with a roof fan, for smoke extraction in the event of a fire, 400ºC/2h High-powered ventilators with roof fan and motorised opening.

More information

AXIAL FLOW CABINET FAN CGT Series

AXIAL FLOW CABINET FAN CGT Series Range of adjustable pitch aerofoil blade, axial flow cabinet fans. Fan casing manufactured from heavy gauge galvanised sheet steel internally lined with 25 mm thickness fireproof fibreglass acoustic insulation

More information

JM Aerofoil Bifurcated 50Hz

JM Aerofoil Bifurcated 50Hz JM Aerofoil Bifurcated 5Hz JM AEROFOIL - BIFURCATED CONTENTS The Bifurcated Fan Range - Introduction 3 Applications 4 Specification 5 Forms of Running, Test Methods & Quality Systems 6 Guide To Fan Selection

More information

Performance. Sound Levels. Impellers. Motors. Accessories

Performance. Sound Levels. Impellers. Motors. Accessories EuroSeries (ESP) Die cast aluminium impellers Fully speed controllable Air Volumes up to 13.89m 3 /s Sizes 250 to 1000 dia protected to IP54 Operating Temperatures from -40 C up to +70 C Insulation Class

More information

HXBR / HXTR Series PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

HXBR / HXTR Series PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series 0 017982 603075 A P P L I C A T I O N S Range of plate mounted axial fans manufactured from high grade galvanised steel

More information

"LCA"- long cased axial fan

LCA- long cased axial fan "LCA"- long cased axial fan Long cased axial fans for industrial/commercial use Thirteen sizes - from 310mm to 1250mm diameter Airflow from 2,200 to 80,000m 3 /hr Single or Three Phase 2, 4 or 6 pole motors

More information

Vent-Axia Sabre Sickle Roof Fans (VSR)

Vent-Axia Sabre Sickle Roof Fans (VSR) Vent-Axia Sabre Sickle Roof Fans (VSR) Features and Benefits High performance roof sickle fan Fully assembled cowl. Optional backdraught shutters and birdguard Moulded from recyclable polymeric material,

More information

V.I.R.T.U.O. Ventilation boxes. Comfort ventilation boxes

V.I.R.T.U.O. Ventilation boxes. Comfort ventilation boxes Comfort ventilation Very wide flow rate range : 0.11 to 9.72 m 3 /s Standard version with lacquered finish casing APPLICATION ventilation are designed for the ventilation of tertiary or industrial buildings,

More information

Axial-flow Fan AFC. Model numbering system AF C / T. Accessories Three phase. Power rate 1.

Axial-flow Fan AFC. Model numbering system AF C / T. Accessories Three phase. Power rate 1. xial-flow Fan FC Construction xial fan designed for installation in a ducted system. Casing of rolled and electro-welded steel sheet, powder coated RL5. Impeller in polypropylene. Casing in acid-proof

More information

ODP SERIES PREMIUM INDUSTRIAL OPEN DRIP PROOF MOTORS C280M to C355LB Frame. Australian Version October 2013

ODP SERIES PREMIUM INDUSTRIAL OPEN DRIP PROOF MOTORS C280M to C355LB Frame. Australian Version October 2013 ODP SERIES PREMIUM INDUSTRIAL OPEN DRIP PROOF MOTORS C280M to C355LB Frame Australian Version October 2013 ODP SERIES (OPEN DRIP PROOF) PREMIUM INDUSTRIAL OPEN DRIP PROOF MOTORS, C280M TO C355LB FRAME

More information

TURBOFLOW TF Contra Rotating Axial Flow Fan

TURBOFLOW TF Contra Rotating Axial Flow Fan TURBOFLOW TF Contra Rotating Axial Flow Fan Select models available for next day delivery TURBOFLOW TF Overview 5 standard sizes from 450mm to 630mm Air volume flow rates up to 4.6 m³/s Static pressures

More information

Turbo Exhausters and Blowers

Turbo Exhausters and Blowers Turbo Exhausters and Blowers Clyde Process Sturtevant Turbo Exhausters and Blowers for continuous duty X Type Turbo Exhausters and Blowers Turbine Type Air Exhausters and Blowers Designed and engineered

More information

KAT. DOUBLE INLET CENTRIFUGAL FAN with Forward Wheels

KAT. DOUBLE INLET CENTRIFUGAL FAN with Forward Wheels KAT DOUBLE INLET ENTRIFUGAL FAN with Forward Wheels KAT Series DOUBLE INLET ENTRIFUGAL FAN with Forward Wheels Kruger Ventilation Industries certifies that the KAT series : version S and - model 9-7 to

More information

AXUS HIGH TEMPERATURE AXIAL FANS

AXUS HIGH TEMPERATURE AXIAL FANS WIDE RANGE OF SMOKE EXTRACT FANS FOR HIGH TEMPERATURE APPLICATIONS. 342 029 2085 8 BENEFITS TRIED & TESTED Nuaire s high temperature fans have been tested in accordance with the latest legislation and

More information

Twin City Fan & Blower

Twin City Fan & Blower BULLETIN 600 Twin City Fan & Blower September 2009 VENTILATING SETS TYPE BCV (Backward Inclined) TYPE BCVU5 (UL 705 Listed) TYPE BCVU2 (UL 762 Listed) TYPE BCVSH (UL Smoke & Heat) TYPE BAV (Airfoil) TYPE

More information

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER MODEL MODEL FEATURES Exhaust air up to 60,116 CFM in static pressure applications up to 1 w.g. Straight-through air flow design results in maximum exhaust efficiency Motor and drives are located outside

More information

GMP-Type. Key Features: Integrated Motor-Pump Units

GMP-Type. Key Features: Integrated Motor-Pump Units Integrated Motor-Pump Units GMP-Type Key Features: Direct coupling between motor and pump Rotation: Right (viewed from shaft end) Electric motor mounting type: special B3-B14 (IEC 34-7) Rated Voltage:

More information

CENTRIFUGAL DIRECT DRIVE FANS CMT-CMB

CENTRIFUGAL DIRECT DRIVE FANS CMT-CMB CENTRIFUGAL DIRECT DRIVE FANS CMT-CMB Applications The CMT-CMB range of fans are suitable for many general and OEM ventilation applications where the extract of nonhazardous heated air is required. The

More information

Series VENTS OVK. Low pressure axial fans in the steel casing with the air capacity up to m 3 /h for wall mounting

Series VENTS OVK. Low pressure axial fans in the steel casing with the air capacity up to m 3 /h for wall mounting AXIAL FANS Series VENTS OV Series VENTS OVK Series VENTS Low pressure axial fans in the steel casing with the air capacity up to 122 m 3 /h for wall mounting Low pressure axial fans in the steel casing

More information

Plate mounted axial flow fans HXBR / HXTR Series

Plate mounted axial flow fans HXBR / HXTR Series Plate mounted axial flow fans manufactured from high grade galvanised steel and provided with a Sickle blade impeller, low sound level, protected against corrosion by cataforesis primer and a polyester

More information

SQUIF HIGH TEMPERATURE FANS

SQUIF HIGH TEMPERATURE FANS FNS HIGH TEMPERTURE CENTRIFUGL SQUIF FOR SMOKE EXTRCT CERTIFIED TO EN12101-3-2002. 366 029 2085 8200 BENEFITS HIGH TEMPERTURE PPLICTION Capable of running continuously at 90ºC, ideal for kitchen canopy

More information

Multifunctional 400ºC/2h and 300ºC/2h roof fans

Multifunctional 400ºC/2h and 300ºC/2h roof fans HTMF Multifunctional 400ºC/2h and 300ºC/2h roof fans Multifunctional 400ºC/2h ceiling fans to work inside fire danger zones, designed for smoke extraction in industrial or similar buildings. 0370-CPR-0544

More information

Powerful centrifugal fans for universal use: The product ranges TEM and REM

Powerful centrifugal fans for universal use: The product ranges TEM and REM Powerful centrifugal fans for universal use: The product ranges TEM and REM The fan ranges TEM and REM offered by Nicotra Gebhardt do present a large fan programme of single inlet centrifugal fans which

More information

Air Moving Solutions. VENTILATING SETs BCV BCVU5 BCVU2 BCVSH BAV FCV

Air Moving Solutions. VENTILATING SETs BCV BCVU5 BCVU2 BCVSH BAV FCV Air Moving Solutions. VENTILATING SETs BCV BCVU5 BCVU2 BCVSH BAV FCV CATALOG 600 March 2012 VentilatingSets Models BCV BCVU5 BCVU2 BCVSH BAV FCV Twin City Fan s line of utility ventilating sets is one

More information

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER MODEL TUB MODEL FEATURES Exhaust air up to 60,116 CFM in static pressure applications up to 1 w.g. Straight-through air flow design results in maximum exhaust efficiency Motor and drives are located outside

More information

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig CENTRIFUGAL FANS HV VAC &

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig CENTRIFUGAL FANS HV VAC & hore nd Offsh arine an ms for Ma geration System & Refrig HV VAC & PRODUCT CATALOGUE CENTRIFUGAL FANS ! "# $ % & " ' (! ) * +,+( -../01..2 PRODUCT CATALOGUE 73-16 CENTRIFUGAL FANS CONTENT PAGE 1. CENTRIFUGAL

More information

TWIN SQUIF FANS RUN & STANDBY SOLUTION FOR ALL 'MOTOR OUT AIRSTREAM' APPLICATIONS. FOR HIGH TEMPERATURE RANGE REFER TO SMOKE SECTION

TWIN SQUIF FANS RUN & STANDBY SOLUTION FOR ALL 'MOTOR OUT AIRSTREAM' APPLICATIONS. FOR HIGH TEMPERATURE RANGE REFER TO SMOKE SECTION TWI FAS TWI SQUIF TECHICAL IFORMATIO TWI SQUIF FAS RU & STADBY SOLUTIO FOR ALL 'MOTOR OUT AIRSTREAM' APPLICATIOS. FOR HIGH TEMPERATURE RAGE REFER TO SMOKE SECTIO 264 TWI FAS TWI SQUIF TECHICAL IFORMATIO

More information

Square Duct Fans - ESTOC Range. Estoc Features. Electrical Supply. Product Code. Sizes 355, 400, 450, 500, 560, 630 and 710.

Square Duct Fans - ESTOC Range. Estoc Features. Electrical Supply. Product Code. Sizes 355, 400, 450, 500, 560, 630 and 710. Square Duct Fans - ESTOC Range Features Sizes from 355 to 71 mm diameter Air flow 1,9 m 3 /h (5.2 m 3 /s) Static pressures up to 115 Pa Maximum temperature from +4 C to +7` C (depending on the model) Adjustable

More information

MODEL UBSRD REMOTE DRIVE UPBLAST PROPELLER ROOF EXHAUSTER

MODEL UBSRD REMOTE DRIVE UPBLAST PROPELLER ROOF EXHAUSTER MODEL UBSRD REMOTE DRIVE UPBLAST PROPELLER ROOF EXHAUSTER MODEL FEATURES Exhaust air up to 52,000 CFM in static pressure applications up to 3/4 w.g. Motor and drives are located outside of the exhaust

More information

Mixed Flow Roof Fans (RMH)

Mixed Flow Roof Fans (RMH) Mixed Flow Roof Fans (RMH) Features and Benefits Motors protected to IP44 Motor insulation Class B Maximum operating temperature 4 C Standard Thermal Overload Protection IP65 P65 service isolator Guard

More information

LC/SC. Long & Short Cased Axial Fans

LC/SC. Long & Short Cased Axial Fans LC/SC Long & Short Cased xial Fans LC/SC contents introduction features & benefits specification performance dimensional data mounting silencer data accessories inverters & DCV controllers additional

More information

Square Mixed Flow Fans (MFQ)

Square Mixed Flow Fans (MFQ) Square Mixed Flow Fans (MFQ) Features and Benefits Motors protected to IP44 Motor insulation Class B Maximum operating temperature +40 C Standard Thermal Overload Protection Sizes 400 to 500 3 phase are

More information

Data sheet. Page: 1 / 5. ETL GGSAV11D BKSBIE3 Inline pump. Operating data. Design

Data sheet. Page: 1 / 5. ETL GGSAV11D BKSBIE3 Inline pump. Operating data. Design Data sheet Page: 1 / 5 Operating data Requested flow rate Operating data determined for maximum inlet pressure Requested developed head 15.00 m Pumped medium Ambient air temperature 20.0 C Fluid temperature

More information

DIRECT-AIR ILB / ILT Series Rectangular duct fans

DIRECT-AIR ILB / ILT Series Rectangular duct fans IN-LINE DUCT FAN Series Rectangular duct fans Range of in-line rectangular duct fan manufactured from galvanised steel sheet and provided with an inspection cover that can be removed to access the motor/impeller

More information

HEAVY DUTY FANS FOR INDUSTRIAL APPLICATIONS

HEAVY DUTY FANS FOR INDUSTRIAL APPLICATIONS HEAVY DUTY FANS FOR INDUSTRIAL APPLICATIONS OUR COMMITMENT TO THE ENVIRONMENT Sodeca has begun a new stage of study and design of new trends in ventilation which will help to preserve the environment and

More information

CBM Series LOW PRESSURE CENTRIFUGAL FANS CBM. Low pressure centrifugal fans. Impeller dynamically balanced. Anti-vibration mounts

CBM Series LOW PRESSURE CENTRIFUGAL FANS CBM. Low pressure centrifugal fans. Impeller dynamically balanced. Anti-vibration mounts LOW PRESSURE CENTRIFUGAL FANS Series Range of double inlet direct driven low pressure centrifugal fans manufactured from galvanised sheet steel. All the models are fitted with forward curved centrifugal

More information

CONTINUO. Radial centrifugal impeller. Radial centrifugal impellers dynamically balanced, according to ISO 1940 standard,

CONTINUO. Radial centrifugal impeller. Radial centrifugal impellers dynamically balanced, according to ISO 1940 standard, RADIAL CENTRIFUGAL FANS CBT-N Series CONTINUO Range of single inlet direct driven centrifugal fans designed for the continuous extraction of air stream up to 120ºC(1). The casings are manufactured from

More information

Aerofoil Ventilation Fans. Fantek. Quality & Performance at Affordable Prices

Aerofoil Ventilation Fans. Fantek. Quality & Performance at Affordable Prices Aerofoil Ventilation Fans Quality & Performance at Affordable Prices GENERAL FEATURES, located in Chennai strives to deliver quality products at affordable costs to all its customers. Our company s vision

More information

Improves fan ef ciency

Improves fan ef ciency Improves fan ef ciency & minimises commisioning time Can be pre-configured to suit your application Creates a Demand Control Ventilation system Member of Danfoss Group Fantech s high performance axial

More information