GSC CONDUIT FITTING SOLUTIONS PRODUCT CATALOG
|
|
- Dwain Snow
- 5 years ago
- Views:
Transcription
1 PRODUCT CATALOG
2 INDEX EMT CONDUIT FITTINGS EMT STRAP (ONE HOLE) P-1 CONDUIT OUTLET BOX COVER P-9 EMT STRAP ( TWO HOLE) P-1 CONDUIT OUTLET BOX TYPE GUA P-9 EMT CONNECTOR P-1 CONDUIT OUTLET BOX TYPE GUAT P-9 EMT COUPLING P-1 CONDUIT OUTLET BOX TYPE GUAX P-9 EMT BENDER P-1 CONDUIT OUTLET BOX TYPE GUAC P-10 RIGID/IMC CONDUIT FITTINGS CONDUIT OUTLET BOX TYPE GUAL P-10 INSULATED BUSHING P-2 CONDUIT OUTLET BOX TYPE GUAN P-10 GROUNDING BUSHING P-2 FLEXIBLE CONDUIT FITTINGS INSULATED BUSHING (SET SCREW) P-2 BX FLEX CONNECTOR STRAIGHT P-11 NIPPLE P-2 BX FLEX CONNECTOR 90 DEG P-11 LOCKNUT P-3 LIQUID TIGHT CONNECTOR STRAIGHT P-11 GROUNDING LOCKNUT P-3 LIQUID TIGHT CONNECTOR 90 DEGREES P-11 CHASE NIPPLE P-3 LIQUID TIGHT CONNECTOR 45 DEGREES P-12 U BOLT P-3 GROUNDED LIQUID TIGHT CONN ST P-12 RIGID CONNECTOR P-4 GROUNDED LIQUID TIGHT CONN 90 DEG P-12 SET SCREW CONNECTOR P-4 GROUNDED LIQUID TIGHT CONN 45 DEG P-12 RAIN TIGHT HUB P-4 PVC CONDUIT FITTINGS RIGID COUPLING P-4 CONDUIT ADAPTOR P-13 SET SCREW COUPLING P-5 HANGERS THREE PIECE COUPLING P-5 BEAM CLAMP P-13 SPLIT COUPLING P-5 BEAM CLAMP P-13 UNION EXP PROOF DESIGN P-5 TECHNOAIRRE NEW UNIVERSAL CONDUIT SUPPORT P-5 TECHNOAIRRE -1 P-14 RIGHT ANGLE CONDUIT SUPPORT P-6 TECHNOAIRRE - 2 P-15 PARALLEL CONDUIT SUPPORT P-6 TECHNOAIRRE - 3 P-16 REDUCING BUSHING STEEL P-6 REDUCING BUSHING MALLEABLE IRON P-6 RIGID STRAP P-7 CLAMP BACK P-7 ENLARGER STEEL P-7 ENLARGER MALLEABLE IRON P-8 CONDUIT BODY COVER P-8 CONDUIT BODY TYPE LB P-8 CONDUIT BODY TYPE LL P-8 CONDUIT BODY TYPE LR P-8 CONDUIT BODY TYPE C P-8 CONDUIT BODY TYPE T P-8 CONDUIT BODY TYPE TB P-9 CONDUIT BODY TYPE X P-9 CATALOG INDEX
3 EMT CONDUIT FITTINGS EMT STRAP (ONE HOLE) EMT STRAP (ONE HOLE) Usage: To clamp EMT conduit to the mounting surface Usage: To connect EMT conduit to boxes or enclosures by set screw ESP /2" ECN /2" ESP /4" ECN /4" ESP " ECN " ESP /4" ECN /4" ESP /2" ECN /2" ESP " ECN " ESP /2" ECN /2" ESP " ECN " ESP /2" ECN /2" ESP " ECN " EMT STRAP (TWO HOLE) EMT STRAP (ONE HOLE) Usage: To clamp EMT conduit on the mounting surface Usage: To join two EMT conduits of same size by set screw ESP /2" ECP /2" ESP /4" ECP /4" ESP " ECP " ESP /4" ECP /4" ESP /2" ECP /2" ESP " ECP " ESP /2" ECP /2" ESP " ECP " ESP /2" ECP /2" ESP " ECP " EMT BENDER Usage: To Bend EMT conduits to a desired angle CAT NO. SIZE UNIT QTY. PACKING EFT /2" EFT /4" EFT " 1 1 P-1
4 RIGID/IMC CONDUIT FITTINGS INSULATED BUSHING INSULATED BUSHING (SET SCREW) Usage:To insulate and smoothen rough edges of threaded conduit to protect conductors Usage:To insulate and smoothen rough edges of threadless conduit to protect conductors RFT /2" RFT /2" RFT /4" RFT /4" RFT " RFT " RFT /4" RFT /4" RFT /2" RFT /2" RFT " RFT " RFT /2" RFT /2" RFT " RFT " RFT /2" RFT /2" RFT " RFT " RFT " RFT " RFT " 5 5 RFT " 5 5 GROUNDING BUSHING Usage:To insulate and smoothen rough edges of conduit to protect conductors and avoid any ground faults NIPPLE Usage:To connect two fittings of female thread or to convert female thread of fitting to male thread RFT /2" RFT /2" RFT /4" RFT /4" RFT " RFT " RFT /4" RFT /4" RFT /2" RFT /2" RFT " RFT " RFT /2" RFT /2" RFT " RFT " RFT /2" RFT /2" RFT " RFT " RFT " RFT " RFT " 5 5 RFT " 5 5 P-2
5 RIGID/IMC CONDUIT FITTINGS LOCKNUT CHASE NIPPLE Usage:To fasten the conduit or fitting Usage:To connect box to conduit coupling or to connect two boxes RFT /2" RFT /2" RFT /4" RFT /4" RFT " RFT " RFT /4" RFT /4" RFT /2" RFT /2" RFT " RFT " RFT /2" RFT /2" RFT " RFT " RFT /2" RFT /2" RFT " RFT " RFT " RFT " RFT " 5 5 RFT " 5 5 GROUNDING LOCKNUT U BOLT Usage:To fasten the conduit or fitting with grounding option Usage:To run and secure the conduits RFT /2" RFT /2" RFT /4" RFT /4" RFT " RFT " RFT /4" RFT /4" RFT /2" RFT /2" RFT " RFT " RFT /2" RFT /2" RFT " RFT " RFT /2" RFT /2" RFT " RFT " RFT " RFT " 5 5 P-3
6 RIGID/IMC CONDUIT FITTINGS RIGID CONNECTOR RAIN TIGHT HUB Usage:To connect the threaded conduit to boxes, enclosures and other fittings Usage:To connect threaded conduit to boxes and enclosures in outdoor locations RCN /2" RCN /2" RCN /4" RCN /4" RCN " RCN " RCN /4" RCN /4" RCN /2" RCN /2" RCN " RCN " RCN /2" RCN /2" RCN " RCN " RCN /2" 5 5 RCN /2" 5 5 RCN " 1 1 RCN " 1 1 RCN " 1 1 RCN " 1 1 RCN " 1 1 RCN " 1 1 SET SCREW CONNECTOR RIGID COUPLING Usage:To connect the conduit to boxes, enclosures and other fittings by set screw Usage:To join threaded conduits of same size RCN /2" RCP /2" RCN /4" RCP /4" RCN " RCP " RCN /4" RCP /4" RCN /2" RCP /2" RCN " RCP " RCN /2" RCP /2" RCN " RCP " RCN /2" 5 5 RCP /2" 5 5 RCN " 1 1 RCP " 1 1 RCN " 1 1 RCP " 1 1 RCN " 1 1 RCP " 1 1 P-4
7 RIGID/IMC CONDUIT FITTINGS SET SCREW COUPLING Usage:To join two conduits by set screw in environment where conduit movement is not possible SPLIT COUPLING RCP /2" RCP " RCP /4" RCP /2" RCP " RCP " 5 5 RCP /4" RCP /2" 1 1 RCP /2" RCP " 1 1 RCP " RCP /2" RCP " UNION - EXPLOSION PROOF DESIGN RCP /2" 5 5 RCP " 1 1 RCP " 1 1 RCP " 1 1 CAT NO. SIZE UNIT QTY. PACKING RCP /2" RCP /4" THREE PIECE COUPLING RCP " Usage:To join threaded conduits of same size in conditions where turning the conduit is difficult RCP /4" RCP /2" RCP " CAT NO. SIZE UNIT QTY. PACKING RCP /2" RCP /2" RCP " 2 2 RCP /4" RCP /2" 2 2 RCP " RCP " 1 1 RCP /4" RCP " 1 1 RCP /2" RCP " 1 1 RCP " RCP /2" RCP " 2 2 UNIVERSAL CONDUIT SUPPORT RCP /2" 2 2 RCP " 1 1 RCP " 1 1 Usage:To join two conduits in conditions where conduits are close to wall and no space is for other couplings Usage:To join threaded conduits of same size in environment with possibility of explosive gases etc. Usage:To run and support the conduits of all sizes RCP " 1 1 CAT NO. SIZE UNIT QTY. PACKING RSP P-5
8 RIGID/IMC CONDUIT FITTINGS RIGHT ANGLE CONDUIT SUPPORT PARALLEL CONDUIT SUPPORT Usage:To reduce the size of conduit or fitting to adapt smaller conduit Usage:To reduce the size of conduit or fitting to adapt smaller conduit RSP /2" RSP /2" RSP /4" RSP /4" RSP " RSP " RSP /4" RSP /4" RSP /2" RSP /2" RSP " RSP " RSP /2" RSP /2" RSP " RSP " RSP /2" RSP /2" RSP " RSP " REDUCING BUSHING REDUCING BUSHING Usage:To reduce the size of conduit or fitting to adapt smaller conduit Usage:To reduce the size of conduit or fitting to adapt smaller conduit RAD /2" X 3/8" RAD /2" X 1" RAD /4" X 1/2" RAD /2" X 1-1/4" RAD " X 1/2" RAD /2" X 1-1/2" RAD " X 3/4" RAD /2" X 2" RAD /4" X 1/2" RAD " X 1-1/4" RAD /4" X 3/4" RAD " X 1-1/2" RAD /4" X 1" RAD " X 2" RAD /2" X 1/2" RAD " X 2-1/2" RAD /2" X 3/4" RAD /2" X 1-1/2" RAD /2" X 1" RAD /2" X 2" RAD /2" X 1-1/4" RAD /2" X 2-1/2" RAD " X 1/2" RAD /2" X 3" RAD " X 3/4" RAD " X 2" RAD " X 1" RAD " X 2-1/2" RAD " X 1-1/4" RAD " X 3" RAD " X 1-1/2" RAD " X 3-1/2" P-6
9 RIGID/IMC CONDUIT FITTINGS RIGID STRAP ENLARGER Usage:To provide support to running conduit and to mount it on mounting surface RSP /2" RAD /2" X 3/8" RSP /4" RAD /4" X 1/2" RSP " RAD " X 1/2" RSP /4" RAD " X 3/4" RSP /2" RAD /4" X 1/2" RSP " RAD /4" X 3/4" RSP /2" RAD /4" X 1" RSP " RAD /2" X 1/2" RSP /2" RAD /2" X 3/4" RSP " RAD /2" X 1" RSP " 5 5 RAD /2" X 1-1/4" RSP " 5 5 RAD " X 1/2" RAD " X 3/4" RAD " X 1" CLAMP BACK RAD " X 1-1/4" RAD " X 1-1/2" Usage:To act as spacer between conduit and mounting surface to prevent buildup of dust, snow etc. CAT NO. SIZE UNIT QTY. PACKING RSP /2" RSP /4" ENLARGER Usage:To adapt the fitting or conduit to the larger size conduit Usage:To adapt the fitting or conduit to the larger size conduit RSP " CAT NO. SIZE UNIT QTY. PACKING RSP /4" RAD /2" X 1" RSP /2" RAD /2" X 1-1/4" RSP " RAD /2" X 1-1/2" RSP /2" RAD /2" X 2" RSP " RAD " X 1-1/4" RSP /2" RAD " X 1-1/2" RSP " RAD " X 2" RSP " RAD " X 2-1/2" RSP " RAD /2" X 1-1/2" RAD /2" X 2" RAD /2" X 2-1/2" RAD /2" X 3" RAD " X 2" RAD " X 2-1/2" RAD " X 3" RAD " X 3-1/2" P-7
10 RIGID/IMC CONDUIT FITTINGS CONDUIT BODY COVER CONDUIT BODY TYPE LR Usage:To act as opening access to conductors through conduit body Usage:To connect running conduits and protect and provide access to conductors RFT /2" RFT /2" RFT /4" RFT /4" RFT " RFT " RFT /4" RFT /4" 5 5 RFT /2" RFT /2" 5 5 RFT " RFT " 1 1 CONDUIT BODY TYPE LB CONDUIT BODY TYPE C Usage:To connect running conduits and protect and provide access to conductors Usage:To connect running conduits and protect and provide access to conductors RFT /2" RFT /2" RFT /4" RFT /4" RFT " RFT " RFT /4" 5 5 RFT /4" 5 5 RFT /2" 5 5 RFT /2" 5 5 RFT " 1 1 RFT " 1 1 CONDUIT BODY TYPE LL CONDUIT BODY TYPE T Usage:To connect running conduits and protect and provide access to conductors Usage:To connect running conduits and protect and provide access to conductors RFT /2" RFT /2" RFT /4" RFT /4" RFT " RFT " RFT /4" 5 5 RFT /4" 5 5 RFT /2" 5 5 RFT /2" 5 5 RFT " 1 1 RFT " 1 1 P-8
11 RIGID/IMC CONDUIT FITTINGS CONDUIT BODY TYPE TB CONDUIT BODY TYPE X Usage:To act as opening access to conductors through conduit body Usage:To connect running conduits and protect and provide access to conductors RFT /2" RFT /2" RFT /4" RFT /4" RFT " RFT " RFT /4" RFT /4" 5 5 RFT /2" RFT /2" 5 5 RFT " RFT " 1 1 CONDUIT OUTLET BOX COVER CONDUIT OUTLET BOX TYPE GUA Usage:To act as opening access to conductors through conduit outlet box Usage:To protect and provide access to conductors in environment with possibility of explosive gases RFT /2" RFT /2" RFT /4" RFT /4" 5 5 RFT " RFT " 5 5 RFT /4" RFT /4" 1 1 RFT /2" RFT /2" 1 1 RFT " RFT " 1 1 CONDUIT OUTLET BOX TYPE GUAT CONDUIT OUTLET BOX TYPE GUAX Usage:To protect and provide access to conductors in environment with possibility of explosive gases Usage:To protect and provide access to conductors in environment with possibility of explosive gases RFT /2" RFT /2" RFT /4" 5 5 RFT /4" 5 5 RFT " 5 5 RFT " 5 5 RFT /4" 1 1 RFT /4" 1 1 RFT /2" 1 1 RFT /2" 1 1 RFT " 1 1 RFT " 1 1 P-9
12 RIGID/IMC CONDUIT FITTINGS CONDUIT OUTLET BOX TYPE GUAC CONDUIT OUTLET BOX TYPE GUAN Usage:To protect and provide access to conductors in environment with possibility of explosive gases Usage:To protect and provide access to conductors in environment with possibility of explosive gases RFT /2" RFT /2" RFT /4" 5 5 RFT /4" 5 5 RFT " 5 5 RFT " 5 5 RFT /4" 1 1 RFT /4" 1 1 RFT /2" 1 1 RFT /2" 1 1 RFT " 1 1 RFT " 1 1 CONDUIT OUTLET BOX TYPE GUAL Usage:To protect and provide access to conductors in environment with possibility of explosive gases CAT NO. SIZE UNIT QTY. PACKING RFT /2" RFT /4" 5 5 RFT " 5 5 RFT /4" 1 1 RFT /2" 1 1 RFT " 1 1 P-10
13 FLEXIBLE CONDUIT FITTINGS BX FLEX CONNECTOR STRAIGHT BX FLEX CONNECTOR 90 DEGREES Usage:To connect flexible conduit to fittings and for use with armored cable Usage:To connect flexible conduit to fittings and for use with armored cable FCN /2" FCN /2" FCN /4" FCN /4" FCN " FCN " FCN /4" FCN /4" FCN /2" FCN /2" FCN " FCN " 5 5 FCN /2" FCN /2" 5 5 FCN " 5 5 FCN " 5 5 FCN /2" 2 2 FCN /2" 2 2 FCN " 2 2 FCN " 2 2 LIQUID TIGHT CONNECTOR STRAIGHT LIQUID TIGHT CONNECTOR 90 DEGREES Usage:To connect liquid tight flexible conduit to fittings and enclosures Usage:To connect liquid tight flexible conduit to fittings and enclosures FCN /2" FCN /2" FCN /4" FCN /4" FCN " FCN " FCN /4" FCN /4" FCN /2" FCN /2" FCN " FCN " 5 5 FCN /2" FCN /2" 5 5 FCN " 5 5 FCN " 5 5 FCN /2" 2 2 FCN /2" 2 2 FCN " 2 2 FCN " 2 2 P-11
14 FLEXIBLE CONDUIT FITTINGS LIQUID TIGHT CONNECTOR 45 DEGREES GROUNDED LIQUID TIGHT CONNECTOR 45 DEG Usage:To connect liquid tight flexible conduit to fittings and enclosures Usage:To connect liquid tight flexible conduit to fittings and enclosures with grounding option FCN /2" FCN /2" FCN /4" FCN /4" FCN " FCN " FCN /4" FCN /4" FCN /2" FCN /2" FCN " 5 5 FCN " 5 5 FCN /2" 5 5 FCN /2" 5 5 FCN " 5 5 FCN " 5 5 FCN /2" 2 2 FCN /2" 2 2 FCN " 2 2 FCN " 2 2 GROUNDED LIQUID TIGHT CONNECTOR STR GROUNDED LIQUID TIGHT CONNECTOR 90 DEG Usage:To connect liquid tight flexible conduit to fittings and enclosures with grounding option Usage:To connect liquid tight flexible conduit to fittings and enclosures with grounding option FCN /2" FCN /2" FCN /4" FCN /4" FCN " FCN " FCN /4" FCN /4" FCN /2" FCN /2" FCN " FCN " 5 5 FCN /2" FCN /2" 5 5 FCN " 5 5 FCN " 5 5 FCN /2" 2 2 FCN /2" 2 2 FCN " 2 2 FCN " 2 2 P-12
15 PVC CONDUIT FITTINGS CONDUIT ADAPTOR Usage:To adapt PVC conduit to metal conduit or fittings CAT NO. SIZE UNIT QTY. PACKING PAD /2" PAD /4" PAD " PAD /4" PAD /2" PAD " PAD /2" PAD " PAD /2" PAD " PAD " PAD " 5 5 GSC CONDUIT FITTING SOLUTIONS HANGERS BEAM CLAMP BEAM CLAMP Usage:To provide support for accessories or under roof hangings Usage:To provide support for accessories or under roof hangings HSP " 1/ HSP021 8 MM HSP " 3/ HSP MM HSP /2" 1/ HSP MM P-13
16 INTRODUCTION TECHNOAIRRE NEW TECHNOAIRRE Technoairre is new section added to the catalog to provide insight into our products and their usage. This section cover questions regarding typical situations and problems faced during layout of electrical raceways which are beyond the scope of ordinary fittings or in some cases increase man hours due to difficulties faced and further makes maintenance troublesome. In this section we will provide solutions for such problems by means of options available for such situations. Once we are through this section we will be able to foresee the problems within the design phase of electrical raceway and thereby plan the solution beforehand which will further avoid delays and decrease effort in terms of man hours in execution phases. SESSION Q-1 How to mount and run the conduits in the raceways? SOL-1 Mounting and running of conduits is an important aspect of laying down electrical raceway. We can use channels and strut channel clamp to give support to conduits during their run or we can use straps (REF. P-1) to mount the conduit on mounting surfaces. Q-2 SOL-2 Conduits have to be placed in open location and strut channel clamps or steel straps are not heavy duty enough. What options I have? For such situations where sheet steel products are not usable rigid strap (REF. P-7)can be used to support and mount conduits on surfaces. This is made of malleable iron therefore heavy duty as compared to steel counterparts and thereby has a longer life Q-3 SOL-3 How to avoid dust accumulation in tight spaces between conduit and mounting surface to ease the maintenance? Clamp back (REF. P-7)can be used as spacer between conduit and mounting surface. Clamp back is designed to fit with rigid strap and prevents build up of dust, snow etc. in the tight spaces. Q-4 How to connect the conduit to boxes or enclosures? SOL-4 There are variety of ways to accomplish this. The most basic is to connect the conduit to a box or enclosure with a locknut (REF. P-3) P-14
17 TECHNOAIRRE Q-5 Is there any other better way to connect conduit to the box or enclosure? SOL-5 Locknut is a basic accessory to connect conduit directly to the enclosure. However rigid connector (REF. P-4)can be used to connect the threaded conduit to enclosure. It provides better fitting and support. Q-6 What is the solution if conduit is not threaded? SOL-6 In case threaded conduit is not required set screw connector (REF. P-4)can be used to connect the conduit to box or other female fitting. Set screw connector grips the conduit by tightening the screw of the connector. Q-7 SOL-7 What if the connection of conduit and box is in outdoor location? How to avoid dust or water from going into the conduits or enclosures? In such situations the possibility of dust or water due to rain entering the system can not be denied. For such locations rain tight hub (REF. P-4)can be used which comes furnished with seal and recessed oring to prevent dust or water from entering the system. Q-8 SOL-8 How to avoid conductor damage during pulling through conduits as they can get damaged by rough edges of conduits Insulated bushing or set screw bushing (REF. P-2)can be used to smoothen the edges of conduits and protect the conductors. These two variants differ in installation depending on conduits whether it is threaded or not. For threaded conduits insulated bushing is used and for threadless conduit set screw bushing is used Q-9 Is it possible to take care of grounding faults at this point only as they may damage the system? SOL-9 Yes, grounding bushing (REF. P-2)is further advancement to insulated bushing as it has a grounding lug attached to it to take care of grounding faults. Q-10 How to join two conduits of same size in long runs? SOL-10 Rigid coupling (REF. P-4)is used to join two threaded conduits of same size as it has female thread on both ends to fit the conduits. P-15
18 TECHNOAIRRE Q-11 Again if conduits are not threaded what can we use? SOL-11 Set screw coupling (REF. P-5)just like set screw connector is designed to join threadless conduits with help of set screws present at both the ends. Q-12 SOL-12 We need to join two conduits of same size but the conduits are fixed at other ends and can not turn to fit on rigid coupling? Rigid coupling requires turning of conduits in order to fit on them. However for such situations Three Piece coupling (REF. P-5)can be used as it acts as union and do not require conduits to be turned to fit on coupling. Q-13 SOL-13 We need to join the conduits of same size but they are placed near wall and tight space does not allow much movement to fit the coupling? In this case the ordinary coupling is difficult to use and may cause more difficulty later in maintenance jobs. Even three piece coupling cant find room in tight space. For such situation split coupling (REF. P- 5)can be used which fits with combination of thread and bolts and is easy to use during maintenance. Q-14 Still we need to join conduits in area with possibility of explosive gases. How can we reduce that risk? SOL-14 Union Explosion proof design (REF. P-5)is built to withstand the impact of expolosion and provide passage to gases upon cooling. This will reduce the impact of explosion to affect the surroundings and other systems in proximity. Q-15 How can we get access to conductors in raceways for future maintenance SOL-15 Conduit bodies (REF. P-8,P-9)are designed to ease the maintenance by providing easy access to conductors and protect them. These are available in different design to suit the need of the system Q-16 What option is available for this in hazardous locations? SOL-16 Conduit outlet boxes (REF. P-9,P-10) have same function as conduit body but are designed to fit in hazardous locations. Explosion proof design render them suitable for this application. These are also available in different designs to suit the needs of the system. P-16
19 GSC CONDUIT FITTING SOLUTIONS CONTACT G.S. CORPORATION #25, Gulab Singh Nagar, Industrial Estate, Jallandhar Punjab, India TEL , FAX
Liquid Tight. Liquid Tight Connectors Reusable Fittings. Straight Connectors. Straight Connectors with Insulated Throat
Liquid Tight Connectors Reusable Fittings Industrial specification grade, screw machined steel, zinc plated UL Rated Liquid Tight Includes sealing washer Bonds conduit to box or enclosure Corrosion resistant
More informationPO Box 847 Greensburg, PA Phone (724) Fax (724) /0
PO Box 847 Greensburg, PA 15601-0847 Phone (724) 838-8320 Fax (724) 838-1544 All Stainless Steel All In Stock www.gibsonstainless.com Price List 114 7/01/08 1/1/16 PRICE LIST 118 Contents Item...Page Made
More informationamericanfittingscorp.com t: e:
Reusable Fittings / Straight Connectors Size Range: 3/8 to 5 Liquid Tight Connectors Reusable Fittings Industrial specification grade, screw machined steel, zinc plated UL Rated Liquid Tight Includes sealing
More informationForm 35 Malleable Iron Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.
NEC/CEC Suitable for use in the following Applications Serve as pulling fittings. Make bends in conduit system. Provide openings for splicing. Connect and change direction of conduit runs. Allow connections
More informationForm 85 Unilets Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum, IMC, and EMT Conduit.
For use with Rigid Steel, Rigid Aluminum, IMC, and EMT Conduit. NEC/CEC Suitable for use in the following Applications Serve as pulling fittings. Make bends in conduit system. Provide openings for splicing.
More informationDEMANDING CONDITIONS, DEMAND THE BEST!
DEMANDING CONDITIONS, DEMAND THE BEST! The Superior Connection for Industrial & Processing Environments OEM Equipment Infrastructure Projects Alternative Energy Data Centers LiquidTIGHT Alloy Steel Electrical
More informationLB125A 1-1/4" LB Form 5 Aluminum Conduit Body. Dimensions and Weight STUD SIZE #10; 0.97 INCH LENGTH; INSULATION SUPPORT
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 LB125A 1-1/4" LB Form 5 Aluminum Conduit Body Appleton/Oz Gedney Catalog Number Manufacturer Description Weight per unit
More informationCondulet Conduit Bodies and Outlet Boxes Hazardous
Condulet Conduit Bodies and Outlet Boxes Hazardous 4F Description Page No. Application/Selection 48, 49 Lubricants HTL 59 STL 59 Conduit Bodies & Outlet Boxes Cylindrical EKC 57 90 Elbow LBH 58 LBY 58
More informationCable Supports. Requirements for Cable Supports in the National Electrical Code reads as follows:
QA1 General Information are used to support cables in vertical raceways or risers. Cable supports relieve the strain that would be placed on terminations, the interior of panels, or other devices to which
More informationConduit Bushings for Rigid Metal Conduit and IMC
Applications Used with a locknut to terminate rigid metal conduit or IMC conduit to a box or enclosure. Features Provides a smooth pulling surface. Material/Finish BU: malleable iron/zinc electroplated
More informationList Price Schedule BL-19. PVC Coated Conduit Conduit Fittings & Accessories. Schedule OC Effective Date Sept. 22, 2008 Supercedes BL-18
PVC Coated Conduit Conduit Fittings & Accessories BL-19 Schedule OC-092208 Effective Date Sept. 22, 2008 Supercedes BL-18 OCAL CONDUIT PRODUCTS LIMITED WARRANTY WARRANTY (5 Years Certified Installers):
More informationGeneral Cable Support Information
General Cable Support Information Applications Used to support cables in vertical raceways or risers. Relieves the strain that would be placed on terminations, the interior of panels, or other devices
More informationCommercial Products. New Products in the Commercial Products Product Line
Commercial Products Section A complete solution combining reliability and expertise in every product, providing you with labor and maintenance savings, simplified installation, and improved productivity
More informationRigid Metal Conduit, IMC or EMT K-Clamps
65178 Rigid Metal Conduit, IMC or EMT K-Clamps Wt. Lbs. Std. Catalog No. Size (In.) Per 100 Pkg. Right Angle Type Right Angle Type Hot Dip/Mechanically Galvanized* For Rigid, IMC, EMT PC-50RA 1/2 37.0
More informationFM8 Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.
NEC/CEC Suitable for use in the following Applications Serve as pulling fittings. Make bends in conduit system. Provide openings for splicing. Connect and change direction of conduit runs. Allow connections
More informationAMERICAN FITTINGS Corporation
AMERICAN FITTINGS Corporation Conduit Fittings Flexible Cord Rigid/IMC Liquid Tight EMT Wire Mesh Think American USA Made Since 1946 2009 Edition PLEASE NOTE THIS CATALOG IS BEING UPDATED AND SHOULD BE
More informationPRODUCT CATALOG. 2010, Halex/Scott Fetzer Company TABLE OF CONTENTS. LIQUID Liquid-Tight Conduit Fittings
Electrical Metallic Tubing Fittings MC & C Cable & Flexible Metallic Conduit Fittings Non-Metallic Sheathed Cable Fittings Liquid-Tight Conduit Fittings Rigid & Intermediate Metallic Conduit Fittings Service
More informationT38 1" T Form 7 Malleable Iron Conduit Body. Material, Color, and Finish Color Gray 0 Zinc Electroplate/Chromate/Epoxy Powder Coat
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 T38 1" T Form 7 Malleable Iron Conduit Body Appleton/Oz Gedney Catalog Number Manufacturer Description Weight per unit
More informationGround Wire Size. 1/2 in /4 in. 2 in /2 in. 3-1/2 in TB. 4 in. 5 in. #4 4/0 AWG 3906-TB
lamps Waterpipe Ground lamps Waterpipe Ground lamps Waterpipe Ground lamps 2-T Ground Wire Size Water Pipe Size 1/2 in., 3/4 in., 1 or rebar 4-10 3-T 1-1/4 in., 1-1/2 in. or 2 in. #6, #4, #2 WG 4 2-1/2
More information320A Single Phase URD Meter Loop Installations
320A Single Phase URD Meter Loop Installations Location: The meter loop shall be mounted on the side of the pedestal facing the consumer's lot. (The side being one of the four flat surfaces of the pedestal
More informationTCI5125 Dusttight Grip " 1.50"NPT Ins
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 TCI5125 Dusttight Grip 1.20-1.50" 1.50"NPT Ins Eaton Wiring Devices Catalog Number Manufacturer Description Weight per
More informationKruppsconduit. Metal Raceway Product Range
Kruppsconduit Metal Raceway Product Range CONDUITS (BS4568 & BS31) Index Kruppsconduit 1-10 EMT Conduit 11-25 Rigid Steel Conduit 25-46 PVC Coated Rigid Conduit 47-71 Flexible Conduit System 72-94 CONDUITS
More informationList Price Schedule BL-20. PVC Coated Conduit Conduit Fittings & Accessories. Schedule OC Effective Date Feb. 16, 2009 Supercedes BL-19
PVC Coated Conduit Conduit Fittings & Accessories BL-20 Schedule OC-021609 Effective Date Feb. 16, 2009 Supercedes BL-19 OCAL CONDUIT PRODUCTS LIMITED WARRANTY WARRANTY (5 Years Certified Installers):
More informationDownloaded from
December 20, 1989 TO SUPERSEDE W-F-408D 30 March 1984 FEDERAL SPECIFICATION FITTINGS FOR CONDUIT, METAL, RIGID (THICK-WALL AND THIN-WALL (EMT) TYPE) This specification is approved by the Commissioner.
More informationSAMPLE. Job Name: Anywhere Water District Construction of Reservoir Suggest'd Equipment Rent Total. Suggest'd Material.
Job Name: Anywhere Water District Construction of Reservoir 1500 Anywhere Water District Construction of Reservoir 1500 Electrical Contractor Sub Bid Qty #Elect Hours Unit Underground Conduit Work $60/hr
More informationCable Connectors & Conduit Sealing Bushings
RA1 Cable Terminators General Information Purpose: Cable Terminators and Sealing Fittings are used on conduit ends and cable ends to effectively seal the cable and conduit. Where Installed: Wherever the
More informationNon-Metallic, Armored Cable, and Flexible Metallic Conduit Fittings
Non-Metallic Sheathed Cable and Portable Cord Connectors Non-Metallic Sheathed Cable Connectors Armored Cable and Flexible Connectors Armored Cable and Flexible Connectors Armored, Metal Clad, and Non-Metallic
More informationSteel Conduits Conduit Fittings Flexible Conduits
Conduits Conduit Fittings Flexible Conduits CONTENT 1. INTRODUCTION VOLTECX products introduction and selecting VOLTECX 2. STEEL CONDUITS VOLTECX BS4568: Part 1: 1970 (Class 4) Conduit IEC 61386-21:2004;
More informationCable Connectors & Conduit Sealing Bushings
RA1 Cable Terminators General Information Purpose: Cable Terminators and Sealing Fittings are used on conduit ends and cable ends to effectively seal the cable and conduit. Where Installed: Wherever the
More informationCP Myers Hubs. Class I, Div. 2 Class II, Div. 1 and 2 Class III. when installed in accordance with the NEC. Features. Material.
Myers Hubs Class I, Div. 2 Class II, Div. 1 and 2 Class III when installed in accordance with the NEC. CP Myers Scru-tite TM and Ground hub are used in the termination of electrical circuits through wall
More informationElectrical Fittings & Supplies
Electrical Fittings & Supplies 12802 Commodity Place Tampa, FL 33626 813-664-9700 www.atlanticind.net The Atlantic Story Atlantic Industrial LLC, a division of QSSI, Inc., is an Americanowned and operated
More informationFM9 Aluminum Unilet Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC.
FM9 Aluminum Unilet Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC. : Conduit Bodies Applications Serve as pulling fittings. Make bends in conduit system. Provide
More informationU-18. Company furnishes and installs: 10. Service lateral and connectors. 11. Conduit package, Amperes.
SERVICE TERMINATION IN A TERMINATION COMPARTMENT DIRECT BURIED OR CONCRETE ENCASED LATERAL ALL 1-PHASE VOLTAGES, 400-800 AMPERES ALL 3-PHASE VOLTAGES, 400-3000 AMPERES ONLY Obtain acceptance for 1-phase
More informationSeismic Sensor Accessories SA, SV & ST 6000 Series
Seismic Sensor Accessories SA, SV & ST 6000 Series Part Number Name Used With Description Housing Material 7295-002 Accelerometer EP Housing SA6200A-X0X; SV6300A-001 Physical protection and access to 1/4-28
More informationFM9 Aluminum Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC.
Applications Serve as pulling fittings. Make bends in conduit system. Provide openings for splicing. Connect and change direction of conduit runs. Allow connections for branch runs. Permit access to conductors
More informationCOMMERCIAL AND INDUSTRIAL FITTINGS: CONDUIT BODIES. Applications
Class I, Division per NEC 50.0(B)() Applications Larger body size facilitates pulling of large and heavy conductors. Specially designed raised cast covers provide additional wiring area. Mogul Unilets
More informationArktite Heavy Duty Circuit Breaking Plugs and Receptacles
1P Arktite Heavy Duty Circuit Breaking s and Receptacles Industrial Heavy Duty Non-Hazardous Areas Application: Arktite circuit breaking plugs and receptacles are used: to supply power to portable electrically
More informationThermocouples W A T L O W
W A T O W Watlow s mineral insulated thermocouples are fast-responding, durable, and capable of handling high temperatures. These thermocouples are manufactured with best-in-class XACTPAK, Watlow s trademark
More informationPVC Couplings. Brass Couplings BRASS COMPRESSION COUPLING 3 -LENGTH PVC COMPRESSION COUPLING BRASS COMPRESSION COUPLING 5 -LENGTH
& FITT Brass Couplings BRASS COMPRESSION COUPL 3 -LENGTH 46331 3/8 1/2 12 120 5.80 46332 1/2 3/4 12 120 7.38 46333 3/4 1 6 72 10.52 46334 1 1 1/4 6 60 13.44 46335 1 1/4 1 1/2 4 48 18.00 46336 1 1/2 4 36
More information1-1/2 AL LB FM7 CND BD. Features. Material, Color, and Finish. Dimensions and Weight. Descriptions. Manufacturer Information
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 LB57SA 1-1/2 Al LB FM7 CND BD Appleton/Oz Gedney Catalog Number Manufacturer Description Weight per unit Product Category
More informationMaterial, Color, and Finish Color Gray 0 Zinc Electroplate/Chromate/Epoxy Powder Coat
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 T37 1 T FM7 CND BD Appleton/Oz Gedney Catalog Number T37 Manufacturer Appleton/Oz Gedney Description FM7 Unilets Type
More informationDouble Hanger Only. Sheave Diameter " 3" Double Hanger Only
32000 Series Fiber Optic s & Quadrants For pulling fiber optic cable, DCD has a special series of sheaves and quadrants that will allow the maximum possible bend radius for the application. All the sheaves
More informationUNDERGROUND SERVICES - SECONDARY
UNDERGROUND SERVICES - SECONDARY Contents - Underground Services... U-1 General Requirements for Underground Service...U-2 Names of Parts for Underground Service... U-3 Service Termination in a Service
More informationStainless Steel Fittings
Locknuts & Bushings LOCKNUTS Eaton's Crouse-Hinds Stainless Steel Fittings deliver unbeatable corrosion protection where you need it, saving you time and money throughout the life of your facility. Superior
More informationControl Circuit and Industrial Interlock
Control Circuit Connectors Overview Defined Any application where electrical connections need protection from water and/or dust entering the contacts or the wiring compartment Russellstoll Line Selections
More informationEY, EYD, & ENY Series
EY, EYD, & ENY Series SELING For Harsh & Hazardous Environments Z H LO C EY SERIES SELING ENY ENY with Nipple (For Vertical or Horizontal Conduit) EY EY with Nipple (For Vertical Conduit) ENY-2 (Fixture
More informationArktite Heavy Duty Circuit Breaking Plugs and Connectors
Arktite Heavy Duty Circuit Breaking Plugs and Connectors 60 A, 600 VAC/250 VDC, 50**-400 hertz Dimensions Page 968 1P Plug Connector Mating APJ Plugs Mating APR Connectors Style 1 Description Cat. # Dia.
More informationFM7 Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.
NEC/CEC Suitable for use in the following Applications Serve as pulling fittings. Make bends in conduit system. Provide openings for splicing. Connect and change direction of conduit runs. Allow connections
More informationBUB400M 4-In Mog Cond Body. Features. Material, Color, and Finish. Dimensions and Weight
380 South Street 7596-763, TX Nacogdoches Phone: 936-569-79 Fax: 936-560-685 BUB00M -In Mog Cond Body Appleton/Oz Gedney Catalog Number Manufacturer Description Weight per unit Product Category Features
More informationThin Wall Conduit Fittings (For EMT Conduit)
Set Screw Type Fittings - Product of the USA FITTINGS To join EMT to a box or enclosure To couple two ends of EMT conduit Straight Connectors Non-Insulated Features: All connectors available with or without
More informationArktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-Hazardous Areas
1P Arktite Heavy Duty Circuit Breaking s and s Industrial Heavy Duty Non-Hazardous Areas Application: Arktite circuit breaking plugs and receptacles are used: to supply power to portable electrically operated
More informationTwo Circuit Trac System TRAC SECTION, JOINERS & FEEDS
Project: Fixture Type: Location: Contact/Phone: PRODUCT DESCRIPTION DIMENSIONS Low-Profile, two-circuit trac sections for surface or pendant mounting. Provides two separate 20-amp circuits from a single
More informationTerminal Boxes Series 8252/1
www.stahl.de > Ex d enclosure made of saltwater-resistant, copper-free aluminium cast alloy > Powder coated to RAL 7032 > Available in 3 different sizes > With DIN rail for standard terminals > Enclosure
More informationCABLE GRIPS Strain-Relief Grips Pulling Grips Support Grips
Tough and dependable, Woodhead cable grips and cord grip bodies are reliable workhorses in any plant environment. They serve as flexible holding devices used to pull cable, rope, or tubing into place,
More informationSpecification Grade Insulated Bushings...DA1 Specification Grade Insulated Grounding Bushings...DA2-DA4. Insulating Bushings & Couplings...
SECTION D INDEX Product Description Page Number Specification Grade Insulated Bushings.....................DA Specification Grade Insulated Grounding Bushings........DA2-DA4 Insulating Bushings & Couplings.......................DA-DA6
More informationMOUNTING SYSTEMS SPECIFICATIONS
MOUNTING SYSTEMS SPECIFICATIONS GENERAL Mounting Systems shall allow Track Systems to be fastened to or from various surfaces in a wide range of safe and approved methods. Mounting Systems shall have a
More informationEngineering Service Specifications. Commercial Single-Phase Current Transformer Metering Schemes
Engineering Service Specifications Commercial Single-Phase Current Transformer Metering Schemes Specifications for Commercial Underground Current Transformer Metering Requirements for a Single-Phase Customer
More informationProduct Specification Guide Expansion and Deflection Couplings. SECTION Raceway and Boxes for Electrical Systems
Product Specification Guide Expansion and Deflection Couplings SECTION 26 05 33 Raceway and Boxes for Electrical Systems Specifier Notes: Delete any information below in Parts 1, 2 or 3 which is not required
More informationSTAINLESS STEEL CONDUIT SYSTEM WITH NPT THREADS
STAINLESS STEEL CONDUIT SYSTEM WITH NPT THREADS SILICONE GASKETS (FDA APPROVED) SMOOTH - EASY TO CLEAN (316) STAINLESS STEEL LID STAINLESS STEEL (316) BODY PATENTED 1 Stainless Steel NPT Conduit System
More informationTwo Circuit Trac System TRAC SECTION, JOINERS & FEEDS
Project: Fixture Type: Location: Contact/Phone: PRODUCT DESCRIPTION DIMENSIONS Low profile, two-circuit trac sections for surface or pendant mounting. Provides two separate 20-amp circuits from a single
More informationNumber Tube I.P.S. Rod Size or O.D. Range Cable H J W
TYPE GAR D-28 FENCE POST GROUNDING CONNECTOR For Parallel or 90 Copper Cable Connection To Rod or Pipe with the Same Connector High copper alloy ground connector for joining a range of cable, parallel
More informationSpec 5 Conduit Bodies, Covers and Gaskets For Rigid Conduit and IMC
NEC/CEC Suitable for use in the following Applications To provide access to conductors for pulling, splicing, maintenance and future changes/ upgrades. Allows connection of straight conduit runs, branch
More informationProduct Information Guide
Product Information Guide Electrical Conduit Fittings Interior & Exterior Coatings Phone: 281-405-8240 Fax: 281-405-8388 Email: Sales@nec-inc.com www.nec-inc.com Service - Quality Nipples, Elbows and Couplings,
More informationORDERING: Specify size, figure number, description, nominal pipe size or special O.D. and C-to-C dimension. C - C LOAD lb.
Fig. 2110 www.pipingtech.com/fig2110 Sway Strut with 4 of Adjustment Engineered spring supports option 1 option 2 ORDERING: Specify size, figure number, description, nominal pipe size or special O.D. and
More informationTamper Proof Downblast Centrifugal Exhaust Ventilators Page
SRSH Tamper Proof Downblast Centrifugal Exhaust Ventilators Page Introduction....................................... 2 SRSH-D Specifications and Dimension Data............. 3 SRSH-B Specifications and
More informationaccqpulse Velocity Profiler Sensor Installation Guide
accqpulse Velocity Profiler Sensor Installation Guide Instruction Sheet #69-7403-012 Released May 2016 Overview This instruction guide is for the installation of the accqpulse shallow water and deep water
More informationELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY
EDSC210 -Way Switch Cooper Crouse-Hinds Catalog Number Manufacturer Description Weight per unit Product Category Features Box Type Contact Configuration Current Rating Voltage Rating Material, Color, and
More informationThe parts you need are the parts we have.
When customers need a part that you don t have and the manufacturer can t deliver in time... That s when you call All Current. PART NEEDED PART NEEDED SORRY? CALL The parts you need are the parts we have.
More informationCONDUIT BODIES CONDUIT BODIES. Phone:
i i Con it Bo ies allea le I on o i i I C con it cond ctors or p llin splicin Tapered threaded hu s - NPT Suita le or use in concrete Threaded LB Conduit Bodies MLB1 1/2 4-11/16 1-5/16 2-1/16 70 70.6 MLB2
More informationOne Circuit Trac System TRAC SECTION, JOINERS & FEEDS T Series
Project: Fixture Type: Location: Contact/Phone: PRODUCT DESCRIPTION DIMENSIONS Low-Profile, single-circuit trac sections for surface or pendant mounting. I-beam cross section provides added strength and
More informationELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY[R] IRON ALLOY (US), COPPER FREE ALUMINUM (CANADA)
804 South Street 75964-726, TX Nacogdoches Phone: 96-569-794 Fax: 96-560-4685 EDS25 -Gang Start/Stop Station Cooper Crouse-Hinds Catalog Number Manufacturer Weight per unit Product Category Features Assembly/Kit
More informationNEC, Inc West Road Houston, Texas Phone: Fax:
Product Information Guide Electrical Conduit Fittings Interior & Exterior Coatings 727 West Road Houston, Texas 778 Phone: 281--82 Fax: 281--8388 Email: Sales@nec-inc.com www.nec-inc.com Service - Quality
More informationELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY
EDS2274 Pos D.E. Selector Switch Cooper Crouse-Hinds Catalog Number Manufacturer Description Weight per unit Product Category Features Box Type SINGLE GANG Contact Configuration 4NO-4NC Number of Circuits
More informationWire Mesh Grip Families
Wire Mesh Grip Families Complete offering of wire mesh grips built tough for industrial applications Arrow Hart supplies a broad selection of strain relief, pulling and support grips in a wide range of
More informationTrough, Wireway & Strut Attributes
Trough, Wireway & Strut Trough, Wireway & Strut Stahlin offers a broad range of auxiliary products designed to complement a full non metallic wiring system. Wire management through a corrosion resistant
More informationPowertite Series Pin and Sleeve Plugs, Connectors and Receptacles
Applications Designed to supply power to portable or fixed electrical equipment such as motor generator units, welders, pumps, compressors, cellular relay stations, and similar apparatus. Ideal for use
More informationTwist Lock - Explosion Proof - Dust Ignition Proof Receptacle Assembly
Twist Lock - Explosion Proof - Dust Ignition Proof Receptacle Assembly Part #: EPO-25A The Larson Electronics EPO-25A explosion proof power outlet provides a durable and secure weatherproof power connection
More informationGeneral Information... Temperature/Resistance Table... Part Numbering Examples for RTD s. High Temperature MgO Elements (RA)...
Page General Information... Temperature/Resistance Table... Part Numbering Examples for RTD s High Temperature MgO Elements (RA).... Leadwire Style RTD s (RB).. Leadwire Style RTD s (RD, RE, RF, or RG
More informationW Series Cast Junction Box Options Boxes Available for Raintight, Watertight, or Submersible Applications
W Series Cast Junction Box Options Boxes Available for Raintight, Watertight, or Submersible Applications This table shows the optional items available on the different types of enclosures shown in this
More informationEFS Non-Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof Malleable Iron Body and Cover. Furnished with Internal Ground Screw.
Explosionproof, Dust-Ignitionproof Malleable Iron Body and Cover. Furnished with Internal Ground Screw. Applications Designed to prevent arcing of enclosed switches in ignitable atmospheres during connect
More informationCable Glands & Accessories
Cable Glands & Accessories This catalog features ITC s extensive range of liquid-tight, strain relief cord connectors (cable glands) and accessories, including locknuts, sealing washers, plugs, etc. These
More informationPIPING. Aluminium pipe for inert gases (5,7 m / 18,7 ft) PAGE 2/ AIRNET Ø (MM / INCH) PARTNUMBER LOT SIZE / ¾" 05
PIPING Aluminium pipe for inert gases (5,7 m / 18,7 ft) 2811 1061 05 20 / ¾" 05 2811 2061 05 25 / 1" 05 PAGE 2/99 2014-11-24 Aluminium pipe for air (2,85 m / 9,4 ft) PIPING 2811 1063 10 20 / ¾" 10 2811
More informationNATURAL HIGH IMPACT STRENGTH COPPER FREE ALUMINUM Number of Wires VAC AT 50 TO 400 HZ/250 VDC
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AllenWatson@elliottelectric.com AR331 30 Amp Pin & Sleeve Recpt 3-W 3-P 250VDC/600vac Cooper Crouse-Hinds Catalog Number
More informationHANGERS, STRUT, AND FITTINGS SUBMITTAL
HANGERS, STRUT, AND FITTINGS SUBMITTAL Prepared By: Submitted by: Enter Company Name INTERNATIONAL SEISMIC APPLICATION TECHNOLOGY A Division of Tomarco Contractor Specialties Enter Project Name 4848 Northam
More informationCOMPACT BUSWAY 40 & 60 AMP HOUSING
40 & 60 AMP HOUSING B40 & HOUSING Each Track Busway housing section consists of an extruded aluminum housing with an insulated strip containing copper conductors mounted on the top interior wall. The aluminum
More informationElectrical Applications. Metal Framing & Cable Tray Superstrut Metal Framing System. Column A. Design Data: Materials: Column B
Electrical Raceway Series 800 Surface Raceway and Lighting Systems Superstrut channel together with snap-in closure strip is listed by Underwriters Laboratories as a surface metal raceway. Other accessories
More informationThin Wall Conduit Fittings (for EMT Conduit)
Set Screw Type Fittings FITTINGS conduit fittings are used: Standard Materials and Finishes: Straight Connectors Non-insulated Couplings 450SUS 1 /2 50 10 451US /4 25 14 452US 1 20 453US 1 /4 5 40 454US
More informationTaxonomies, Classifications, and Categories CIRCUIT BREAKING, COMPRESSOR, CONVEYOR, MOTOR GENERATOR SET, POLARIZED, WELDER
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AP20467S22 3W-4P 200A Plug Cooper Crouse-Hinds Catalog Number AP20467S22 Manufacturer Cooper Crouse-Hinds Description
More informationInstruction Sheet for Powertite Plug, Connector and Receptacle
330087 Instruction Sheet for Powertite Plug, Connector and Receptacle Powertite 200 Amp Pin & Sleeve Receptacles, Cable Connectors and Plugs: NEMA 4X. 600 Volt AC, 250 Volt DC. Wire Recess Diameter:.687.
More informationDiameters 10 Length w/ Coupling 5 Length w/ Coupling Trade Size Metric Size OD ID Wt./Ft. Type 304 Type 316 Type 304 Type 316
STINLESS STEEL ONDUIT Diameters 10 Length w/ oupling 5 Length w/ oupling Trade Size Metric Size OD ID Wt./Ft. Type 04 Type 16 Type 04 Type 16 ½ 16 0.840 0.620 0.82 S40510T00 S60510T00 S40505T00 S60505T00
More informationIndex. Flexcor Wire Mesh Grips K-1
Fittings available in male straight, female straight, 45 and 90 designs for fast installation in all kinds of applications. Corrosion-resistant, die cast aluminum fitting with watertight seal (Deluxe Cord
More informationINSTALLATION INSTRUCTIONS 2 AND 2 ½ TURBO EXHAUST SYSTEMS HARDTOP AND SEDANS ONLY
INSTALLATION INSTRUCTIONS 2 AND 2 ½ TURBO EXHAUST SYSTEMS HARDTOP AND SEDANS ONLY Parts supplied with your system. Please check contents carefully before starting installation. Qty Description 2 Exhaust
More informationEPOXY POWDER COATED COPPER FREE ALUMINUM
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AJA510 Alum MTG Unilet Appleton/Oz Gedney Catalog Number Manufacturer Description Weight per unit Product Category Features
More informationAluminium Conduit. Kopex Martel. Fittings. Liquid Tight Fittings Coupler Connector. PVC Coated Conduit. Fittings. Egatu
Rigid Conduit Fittings Elbows Couplings Connectors Nipples Pulling Elbows Long & Short Elbows Piece Coupling Hubs Reducing Washers & Bushings Male Enlargers Female Reducers Straps, Hangers & Clamps Unions
More informationNanometrics Solar Power System
Nanometrics Solar Power System Installation Guide Nanometrics Inc. Kanata, Ontario Canada 2003 Nanometrics Inc. All Rights Reserved. Installation Guide The information in this document has been carefully
More informationAluminum Conduit Bodies, Covers and Gaskets For Rigid Conduit & IMC.
NEC/CEC Suitable for use in the following Applications To provide access to conductors for pulling, splicing, maintenance and future changes/upgrades. Allows connection of straight conduit runs, branch
More informationControl Circuits Connectors Type SK & SKW Overview
Control Circuits Connectors Type SK & SKW Overview 20 Amp, 250 Volts AC or DC, 600 Volts AC Max. Rating Load-Breaking Multi-Circuit Receptacles, Plugs, Connectors and Inlets Features and Benefits Type
More informationProduct Catalog. Fittings ½ AIR PIPE FITTINGS Fitting, 1/2 Air Pipe End Cap Coupler, with Tank Valve
To complement our extensive line of cable pressurization products, System Studies also sells a variety of air pipe and pressure tube fittings. This section of the catalog describes these commonly used
More informationPowertite Series Pin and Sleeve Plugs, Connectors and Receptacles
Applications Designed to supply power to portable or fixed electrical equipment such as motor generator units, welders, pumps, compressors, cellular relay stations, and similar apparatus. Ideal for use
More informationW-Series Junction Boxes
W-Series Junction Boxes Application and Selection Junction boxes, designed for hazardous and non-hazardous locations, are used in a variety of industries to perform the following functions: As a pull box
More information