COMMERCIAL AND INDUSTRIAL FITTINGS: CONDUIT BODIES. Applications
|
|
- Bonnie Barnett
- 5 years ago
- Views:
Transcription
1 Class I, Division per NEC 50.0(B)() Applications Larger body size facilitates pulling of large and heavy conductors. Specially designed raised cast covers provide additional wiring area. Mogul Unilets for pulling straight, 5 or 90 angle turns and/or making taps and splices. Features Exclusive built-in rollers facilitate cable pulling. Available on NEC 6x8x Series Moguls (C, LB and UB) in sizes -/ and up. Smooth, rounded integral bushing in each hub protects conductor insulation. Accurately tapped, tapered threads for tight, rigid joints and ground continuity. Covers have captive stainless steel screws to speed installation, prevent freezing of screws. LB and UB Moguls Length Requirement: distance between centerline of each hub bushing (conduit stop) exceeds six times the trade diameter of the conduit per NEC 3.8(A)(). Bending Space Requirement: these moguls also meet the NEC 3.8(A)() Exception requirement spelled out in NEC 3.6(A) Table. C Moguls Length Requirement: distance between centerline of each hub bushing (conduit stop) exceeds eight times the trade diameter of the conduit per NEC 3.8(A)(). Bending Space Requirement: not applicable. LL and LR Moguls Like LB moguls, these moguls have an end hub. The second hub is in the side (LL left and LR right) instead of the back. T Moguls These are like C moguls ( thru ), except with an additional middle side hub. Distance between the centerline of each C hub conduit stop exceeds eight times the trade diameter of the conduit per NEC 3.8(A)(). Standard Materials Bodies and covers: malleable iron or copperfree (/0 of % max.) aluminum Gaskets: neoprene Screws: stainless steel Standard Finishes Malleable iron bodies and covers: triple-coat () zinc electroplate, () chromate and (3) epoxy powder coat Aluminum bodies and covers: epoxy powder coat NEC/CEC Certifications and Compliances UL Standard: 5B UL Listed: E57 CSA Standard: C. No. 8.3 CSA Certified: NEMA Standard: FB- C NEC 8x LB - NEC 6x LB -/ - NEC 6x UB NEC 6x LR NEC 6x LL NEC 6x T NEC 8x Rollers make cable-pulling easier, eliminate insulation damage If less than maximum conductors permitted by NEC are used, smaller wires may be used additionally through LL, LR or T hubs. If large conductors are required to be bent in LL, LR or T direction, order junction boxes instead. See Enclosures and Junction Boxes. 68 Visit our website at or contact us at (800) February 07
2 Class I, Division per NEC 50.0(B)() Hub Size Max. Wire Fill Body, Cover and Gasket Cover and Gasket Malleable Iron Aluminum Gasket Only Malleable Iron Aluminum C NEC 8X (3) # BC00-M BC00-A BG00 BKG00-M BKG00-A -/ (3) # /0 BC5-M BC5-A BGC5 BKGC5-M BKGC5-A - -/ (3) # 3/0 BC50-M BC50-A BG50 BKG50-M BKG50-A (3) 300 BC00-M BC00-A BGC00 BKGC00-M BKGC00-A -/ (3) 00 BC50-M BC50-A BGC50 BKGC50-M BKGC50-A 3 (3) 700 BC300-M BC300-A BGC300 BKGC300-M BKGC300-A -/ - 3-/ (3) 900 BC350-M BC350-A BGC350 BKGC350-M BKGC350-A (3) 000 BC00-M BC00-A BGC00 BKGC00-M BKGC00-A LB NEC 6X (3) # BLB00-M BLB00-A BG00 BKG00-M BKG00-A -/ (3) # /0 BLB5-M BLB5-A BGL5 BKGL5-M BKGL5-A UB NEC 6X - -/ - - -/ (3) # 3/0 BLB50-M BLB50-A BG50 BKG50-M BKG50-A (3) 300 BLB00-M BLB00-A BGL00 BKGL00-M BKGL00-A -/ (3) 00 BLB50-M BLB50-A BGL50 BKGL50-M BKGL50-A 3 (3) 700 BLB300-M BLB300-A BGL300 BKGL300-M BKGL300-A 3-/ (3) 900 BLB350-M BLB350-A BGL350 BKGL350-M BKGL350-A (3) 000 BLB00-M BLB00-A BGL00 BKGL00-M BKGL00-A (3) # BUB00-M BUB00-A BG00 BKG00-M BKG00-A -/ (3) # /0 BUB5-M BUB5-A BGL5 BKGL5-M BKGL5-A -/ (3) # 3/0 BUB50-M BUB50-A BG50 BKG50-M BKG50-A (3) 300 BUB00-M BUB00-A BGL00 BKGL00-M BKGL00-A -/ (3) 00 BUB50-M BUB50-A BGL50 BKGC50-M BKGC50-A 3 (3) 700 BUB300-M BUB300-A BGL300 BKGU300-M BKGU300-A 3-/ (3) 900 BUB350-M BUB350-A BGL350 BKGC350-M BKGC350-A -/ - (3) 000 BUB00-M BUB00-A BGL00 BKGU00-M BKGU00-A Furnished with rollers for easier cable pulling. Visit our website at or contact us at (800) February 07 69
3 Class I, Division per NEC 50.0(B)() Hub Size Max. Wire Fill Body, Cover and Gasket Cover and Gasket Malleable Iron Aluminum Gasket Only Malleable Iron Aluminum LL NEC 6X (3) # BLL00-M BLL00-A BG00 BKG00-M BKG00-A -/ (3) # BLL5-M BLL5-A BGL5 BKGL5-M BKGL5-A -/ (3) # /0 BLL50-M BLL50-A BG50 BKG50-M BKG50-A - (3) # /0 BLL00-M BLL00-A BGL00 BKGL00-M BKGL00-A LR NEC 6X (3) # BLR00-M BLR00-A BG00 BKG00-M BKG00-A -/ (3) # BLR5-M BLR5-A BGL5 BKGL5-M BKGL5-A -/ (3) #/0 BLR50-M BLR50-A BG50 BKG50-M BKG50-A - (3) # /0 BLR00-M BLR00-A BGL00 BKGL00-M BKGL00-A T NEC 8X (3) # BT00-M BT00-A BG00 BKG00-M BKG00-A - -/ - Wiring Capacity for Mogul Bodies with Covers: Malleable Iron and Aluminum -/ (3) # BT5-M BT5-A BGC5 BKGC5-M BKGC5-A -/ (3) #/0 BT50-M BT50-A BG50 BKG50-M BKG50-A (3) # /0 BT00-M BT00-A BGC00 BKGC00-M BKGC00-A -/ (3) 300 BT50-M BT50-A BGC50 BKGC50-M BKGC50-A 3 (3) 350 BT300-M BT300-A BGC300 BKGC300-M BKGC300-A 3-/ (3) 350 BT350-M BT350-A BGC350 BKGC350-M BKGC350-A (3) 350 BT00-M BT00-A BGC00 BKGC00-M BKGC00-A Hub Size Mogul Capacity dm 3 (in 3 ) Hub Size Mogul Capacity dm 3 (in 3 ) -/ -/ C, LB, LL, LR, T, UB 0.50 (3.00) -/ C, T 5.9 (335.00) LB 3. (0.00) C, T 0.8 (50.00) UB 6.5 (375.00) LB 0.79 (8.00) C, T 7.78 (75.00) LL, LR 0.69 (.00) 3 LB 5.65 (35.00) UB 0.66 (0.00) UB 7.9 (5.00) C, LL, LR, T.5 (93.00) C, T 3.60 (830.00) LB.75 (07.00) 3-/ LB 8.9 (500.00) UB.9 (9.00) UB 3.77 (80.00) C, T.3 (3.00) C, T 6.55 (00.00) LB.37 (5.00) LB.3 (70.00) LL, LR, UB.0 (3.00) UB 5.73 (960.00) 70 Visit our website at or contact us at (800) February 07
4 Class I, Division per NEC 50.0(B)() Bending Radius of Moguls Catalog Number Hub Size R Millimeters BLB00-A,M. (.63) 66.8 (.63) R LB Mogul - LB BLB5-A,M -/ 57. (.5) 9. (3.63) BLB50-A,M -/ 66.8 (.63) 0.9 (.3) BLB00-A,M 76. (3.00) 7.0 (5.00) BLB50-A,M -/ 98.6 (3.88) 58.8 (6.5) BLB300-A,M (5.00) 03. (8.00) BLB350-A,M 3-/ 7.0 (5.00).9 (8.38) LB Mogul -/ - UB Mogul - UB Compliances with NEC Bending Space Requirements Bending Space Defined NEC 3.8(A)() Exception. This article applies to LB and UB Moguls, defines bending space and refers to NEC 3.6(B) Table as guideline for determining minimum bending space distance. Bending space is illustrated as Dimension A below: BLB00-A,M 58.8 (6.5) 60. (0.5) BUB00-A,M.3 (.50) 39.7 (5.50) BUB5-A,M -/ 7.6 (.63) 5. (6.00) BUB50-A,M -/ 77.8 (7.00) 5.9 (8.50) BUB00-A,M 90.5 (7.50).3 (9.50) BUB50-A,M -/ (3.3) (5.50) BUB300-A,M (3.88) 8.8 (6.88) BUB350-A,M 3-/ 50.7 (9.75) (3.5) BUB00-A,M 57. (0.75) 68.7 (.75) Bending Space of Moguls (Dim. A in sketches at left) Mogul Size Distance LB, UB -/ -/ LB, UB 3-/ -/ LB, UB LB, UB 5 -/ LB, UB 6 3 LB, UB 8 3-/ LB, UB 8 AWG or Circular-Mill. Minimum Wire Bending Space NEC 3.6(B) Table: The applicable portion of this table is shown below. Only the Wire Terminal column is retained, because the others are not applicable. Example for using table below and table at right: 350MCM wire size requires 5 bending space. A LB or UB Appleton Mogul is suitable. LB, UB 0 Size of Wire Wire per Terminal Min. Bending Space LB Mogul - -0 Not Specified LB Mogul -/ - NOTE ON RADIUS TABLE: Secure cable or wire bending radius from manufacturer. Then select a mogul having this radius or more. If radius is 6-/, an LB -/ mogul or BUB -/ mogul is suitable. NOTE ON NEC 3.6(B) TABLE: Because cable sizes vary, table is limited to single wire sizes. Use as guideline only for cable sizes / -3 -/ / MCM -/ MCM MCM MCM MCM 8,000-,50 MCM 0 UB Mogul -,500-,000 MCM Visit our website at or contact us at (800) February 07 7
5 Class I, Division per NEC 50.0(B)() Applicable NEC References for C, LB and UB Moguls Straight Pull Length Requirements: NEC 3.8(A)() C Moguls... shall not be less than eight times the trade diameter of the largest raceway. (See table at right.) Angle or U Pull Length Requirements: NEC 3.8(A)() LB, UB Moguls The distance between each raceway entry inside the box and the opposite wall of the box shall not be less than six times the trade diameter of the largest raceway. (See next page.) Bending-Space Requirements: NEC 3.8(A)(). Exception 3.6(A) Table LB, UB Moguls Where a conduit or cable entry is in the wall of a box or conduit body opposite to a removable cover. (See dim. A, table right) Length and Bending Space Requirements: C Mogul thru LB Mogul thru LB Mogul -/ thru UB Mogul thru BENDING SPACE EXAMPLE: LB with 3 hubs (Cat. No. BLB300-M) using 500 MCM wire with four conductors. Table on next page shows that, in this example, NEC requires a bending space of 6 and that the Appleton 3 LB provides a bending space of 8. * Dimension A is bending space. C Moguls Straight Pulls: Maximum Number of Conductors, Minimum Lengths Wire Size➊ Maximum Number of Conductors per NEC ➋ Length Requirements (Conduit Stop to Conduit Stop) Maximum Number of Length Requirements (Conduit Stop to Conduit Stop) Conductors NEC➌ Appleton per NEC ➋ NEC➌ Appleton Hubs BC00-M and BC00-A -/ Hubs BC5-M and BC5-A / Hubs BC50-M and BC50-A Hubs BC00-M and BC00-A / Hubs BC50-M and BC50-A 3 Hubs BC300-M and BC300-A / Hubs BC350-M and BC00-A Hubs BC00-M and BC00-A NEC 3.8(A), 3(A)(). Limited to minimum # wire. NEC Chapter 9, Table 3B. NEC 370.8(A)(). This is 8 times conduit trade size. 7 Visit our website at or contact us at (800) February 07
6 Class I, Division per NEC 50.0(B)() LB and UB Moguls- Angle or U Pulls: Max. No. Conductors, Min. Lengths, Min. Bending Spaces Wire Size➊ Maximum Number of Conductors per NEC ➋ Length Requirements (Conduit Stop to Conduit Stop) (A) Bending Space Requirements NEC➌ Appleton NEC➌ Appleton Maximum Number of Conductors per NEC ➋ Length Requirements (Conduit Stop to Conduit Stop) NEC➌ Appleton (A) Bending Space Requirements NEC➌ Appleton Hubs BLB00-M, BLB00-A, BUB00-M and BUB00-A -/ Hubs BLB5-M, BLB5-A, BUB5-M and BUB00-A 6 6 -/ 7 7-/ 7-/ 3-/ / 6 7-/ 7-/ 3-/ / -/ 5 7-/ 7-/ -/ 3-/ / 7-/ 3 3-/ / 7-/ 3-/ 3-/ -/ Hubs BLB50-M, BLB50-A, BUB50-M and BUB50-A Hubs BLB00-M, BLB00-A, BUB00-M and BUB00-A / -/ / 7 3-/ / 6 3-/ / / Hubs BLB50-M, BLB50-A, BUB50-M and BUB50-A 3 Hubs BLB300-M, BLB300-A, BUB300-M and BUB300-A / / / / / / / / / Hubs BLB350-M, BLB350-A, BUB350-M and BUB350-A Hubs BLB00-M, BLB00-A, BUB00-M and BUB00-A / 8 3 -/ / / / 8 3-/ / 8 -/ NEC 3.8(A). Limited to minimum # wire. NEC Chapter 9, Table 3B. NEC 3.8(A)() This is 6 times conduit trade size. NEC 3.8(A)() Exception (3.6(B) Table). This is distance A bending space illustrated on preceding page. Visit our website at or contact us at (800) February 07 73
7 Class I, Division per NEC 50.0(B)() Dimensions in Millimeters Mogul C T LL, LR Hub Trade Size -/ -/ -/ 3 3-/ -/ -/ -/ 3 3-/ -/ -/ s C, T Furnished with rollers for easier cable pulling. Dimensions in Millimeters s LB, LL, LR A B C D E F G H J K (9.8) (.75) (.38) (.88) (6.63) (0.9) (.) (.88) (.00) (3.3) (.38) (.88) (7.69) (.6) (3.00) (.9) (3.9) (3.75) (3.3) (.50) (9.3) (.38) (3.38) (.56) (7.9) (.) (3.3) (.50) (3.00) (.63) (.00) (3.8) (3.5) (5.3) (.63) (3.75) (7.50) (.8) (.63) (3.63) (6.88) (5.9) (.63) (3.63) (.00) (.6) (5.) (.38) (3.38) (7.9) (5.63) (.50) (.9) (.50) (6.69) (.88) (35.38) (7.56) (5.63) (.50) (8.9) (.75) (7.06) (5.5) (9.8) (.75) (.38) (.88) (6.63) (3.5) (0.9) (.) (.88) (.00) (3.3) (.38) (.88) (8.56) (3.38) (.6) (3.00) (.9) (3.9) (3.75) (3.3) (.50) (0.38) (.3) (.38) (3.38) (.56) (7.9) (.) (3.3) (.50) (.3) (.3) (.63) (.00) (3.8) (3.5) (5.3) (.63) (3.75) (8.69) (6.00) (.8) (.63) (3.63) (6.88) (5.9) (.63) (3.63) (.9) (6.00) (.6) (5.) (.38) (3.38) (7.9) (5.63) (.50) (6.9) (7.5) (.50) (6.69) (.88) (35.38) (7.56) (5.63) (.50) (30.9) (7.5) (.75) (7.06) (5.5) (8.9) (.75) (.38) (.88) (6.63) (3.5) (0.9) (.) (7.88) (.88) (9.69) (3.3) (.38) (.88) (7.5) (3.38) (.6) (3.00) (8.50) (.9) (3.00) (3.75) (3.3) (.50) (0.38) (.3) (.38) (3.38) (.63) (.56) (.63) (5.00) (3.3) (.50) (.8) (.3) (.63) (.56) (.9) (3.) Number of Cover Holes 7 Visit our website at or contact us at (800) February 07
8 Class I, Division per NEC 50.0(B)() Dimensions in Millimeters Mogul LB UB Hub Trade Size -/ -/ -/ 3 3-/ -/ -/ -/ 3 3-/ LB -/" thru " UB Dimensions in Millimeters Number A B C D E G H J K L of Cover Holes (8.9) (3.63) (.38) (.88) (6.63) (0.9) (.) (7.88) (.88) (.88) (9.69) (.75) (.38) (.88) (6.3) (.6) (3.) (8.50) (.63) (.6) (3.00) (5.5) (3.3) (.50) (9.3) (.38) (3.9) (.63) (3.06) (.38) (.63) (6.3) (3.3) (.50) (0.75) (.63) (.88) (.9) (3.) (.69) (7.88) (8.00) (5.88) (3.50) (3.75) (.3) (.3) (5.8) (.56) (.06) (0.00) (5.88) (3.50) (7.00) (.50) (5.3) (8.50) (5.38) (.3) (0.5) (7.00) (.63) (9.88) (3.00) (.75) (.38) (6.63) (7.50) (.50) (7.00) (.63) (3.00) (3.5) (6.38) (.38) (7.00) (9.63) (3.50) (.38) (.88) (6.63) (.) (8.) (.88) (0.5) (.3) (.38) (.88) (6.3) (3.00) (8.9) (.9) (3.69) (.63) (3.3) (.50) (9.3) (3.38) (.9) (.56) (5.5) (5.00) (3.3) (.50) (0.75) (.56) (3.38) (3.8) (.88) (7.06) (.63) (3.75) (7.50) (5.) (0.3) (.38) (.88) (7.3) (.63) (3.75) (7.50) (6.8) (0.3) (.38) (30.88) (0.3) (5.63) (.50) (.88) (8.) (7.50) (5.5) (30.88) (0.3) (5.63) (.50) (.88) (8.) (7.50) (5.5) Furnished with rollers for easier cable pulling. Visit our website at or contact us at (800) February 07 75
BUB400M 4-In Mog Cond Body. Features. Material, Color, and Finish. Dimensions and Weight
380 South Street 7596-763, TX Nacogdoches Phone: 936-569-79 Fax: 936-560-685 BUB00M -In Mog Cond Body Appleton/Oz Gedney Catalog Number Manufacturer Description Weight per unit Product Category Features
More informationForm 35 Malleable Iron Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.
NEC/CEC Suitable for use in the following Applications Serve as pulling fittings. Make bends in conduit system. Provide openings for splicing. Connect and change direction of conduit runs. Allow connections
More informationFM8 Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.
NEC/CEC Suitable for use in the following Applications Serve as pulling fittings. Make bends in conduit system. Provide openings for splicing. Connect and change direction of conduit runs. Allow connections
More informationForm 85 Unilets Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum, IMC, and EMT Conduit.
For use with Rigid Steel, Rigid Aluminum, IMC, and EMT Conduit. NEC/CEC Suitable for use in the following Applications Serve as pulling fittings. Make bends in conduit system. Provide openings for splicing.
More informationSpec 5 Conduit Bodies, Covers and Gaskets For Rigid Conduit and IMC
NEC/CEC Suitable for use in the following Applications To provide access to conductors for pulling, splicing, maintenance and future changes/ upgrades. Allows connection of straight conduit runs, branch
More informationFM7 Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.
NEC/CEC Suitable for use in the following Applications Serve as pulling fittings. Make bends in conduit system. Provide openings for splicing. Connect and change direction of conduit runs. Allow connections
More informationFM9 Aluminum Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC.
Applications Serve as pulling fittings. Make bends in conduit system. Provide openings for splicing. Connect and change direction of conduit runs. Allow connections for branch runs. Permit access to conductors
More informationT38 1" T Form 7 Malleable Iron Conduit Body. Material, Color, and Finish Color Gray 0 Zinc Electroplate/Chromate/Epoxy Powder Coat
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 T38 1" T Form 7 Malleable Iron Conduit Body Appleton/Oz Gedney Catalog Number Manufacturer Description Weight per unit
More informationFM9 Aluminum Unilet Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC.
FM9 Aluminum Unilet Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC. : Conduit Bodies Applications Serve as pulling fittings. Make bends in conduit system. Provide
More informationLB125A 1-1/4" LB Form 5 Aluminum Conduit Body. Dimensions and Weight STUD SIZE #10; 0.97 INCH LENGTH; INSULATION SUPPORT
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 LB125A 1-1/4" LB Form 5 Aluminum Conduit Body Appleton/Oz Gedney Catalog Number Manufacturer Description Weight per unit
More informationMaterial, Color, and Finish Color Gray 0 Zinc Electroplate/Chromate/Epoxy Powder Coat
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 T37 1 T FM7 CND BD Appleton/Oz Gedney Catalog Number T37 Manufacturer Appleton/Oz Gedney Description FM7 Unilets Type
More information1-1/2 AL LB FM7 CND BD. Features. Material, Color, and Finish. Dimensions and Weight. Descriptions. Manufacturer Information
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 LB57SA 1-1/2 Al LB FM7 CND BD Appleton/Oz Gedney Catalog Number Manufacturer Description Weight per unit Product Category
More informationAluminum Conduit Bodies, Covers and Gaskets For Rigid Conduit & IMC.
NEC/CEC Suitable for use in the following Applications To provide access to conductors for pulling, splicing, maintenance and future changes/upgrades. Allows connection of straight conduit runs, branch
More informationForm 7 Iron Conduit Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.
NEC/CEC Suitable for use in the following Applications Serve as pulling fittings. Make bends in conduit system. Provide openings for splicing. Connect and change direction of conduit runs. Allow connections
More informationConduit Outlet Boxes and Bodies: Malleable Iron or Aluminum; Explosionproof, Dust-Ignitionproof UNILETS for use with Threaded Metal Conduit.
-2 Conduit Outlet Boxes and Bodies: Malleable Iron or Aluminum; UNILETS for use with Threaded Metal Conduit. Applications Meet a wide range of classified area requirements. Corrosion-resistant ideal indoors
More informationEFS Non-Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof Malleable Iron Body and Cover. Furnished with Internal Ground Screw.
Explosionproof, Dust-Ignitionproof Malleable Iron Body and Cover. Furnished with Internal Ground Screw. Applications Designed to prevent arcing of enclosed switches in ignitable atmospheres during connect
More informationEDS Factory Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof UNILETS for Use with Threaded Metal Conduit.
UNILETS for Use with Threaded Metal Conduit. Class I, Division 1 and 2, Groups B, C, D Applications Designed to prevent arcing of enclosed switches in ignitable atmospheres during connect and disconnect
More informationConduit Bushings for Rigid Metal Conduit and IMC
Applications Used with a locknut to terminate rigid metal conduit or IMC conduit to a box or enclosure. Features Provides a smooth pulling surface. Material/Finish BU: malleable iron/zinc electroplated
More informationCONTROLS: NEC/CEC EXPLOSIONPROOF CONTROL STATIONS AND SWITCHES. Applications. Illustrated Features
Explosionproof, Dust-Ignitionproof Malleable Iron Body and Cover. Furnished with Internal Ground. Applications Designed to prevent arcing of enclosed switches in ignitable atmospheres during connect and
More informationEDS Factory Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof UNILETS for Use with Threaded Metal Conduit.
EDS Factory Sealed Tumbler Switches UNILETS for Use with Threaded Metal Conduit. Class I, Division 1 and 2, Groups B, C, D NEMA 7 B CD, 9EFG Applications Designed to prevent arcing of enclosed switches
More informationEFS Non-Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof Malleable Iron Body and Cover. Furnished with Internal Ground Screw.
EFS Non-Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof Malleable Iron Body and Cover. Furnished with Internal Ground Screw. Controls CONTROLS: HAZARDOUS LOCATION CONTROL STATIONS AND SWITCHES
More informationApplications. Separate sealing chamber and switch construction. Used on 20 Amp 4-way and all 30 Amp models.
Contender Series Factory Sealed Front Operated Tumbler Switches Malleable Iron Body and Cover. Furnished with Internal Ground. NEMA 3, 7CD, 9EFG Applications Designed to prevent arcing of enclosed switches
More informationContender Series Factory Sealed Control Stations and Pilot Lights Explosionproof, Dust-Ignitionproof Furnished with Internal Ground Screw.
Contender Series Factory Sealed Control Stations and Pilot Lights Furnished with Internal Ground Screw. Applications Push buttons and selector switches are used in conjunction with contactors or magnetic
More informationU-Line Contender Factory Sealed 20 Amp Plugs and Receptacles Explosionproof, Dust-Ignitionproof
U-Line Contender Factory Sealed 20 Amp Plugs and Receptacles Explosionproof, Dust-Ignitionproof Class I, Groups C, D Class I, Division 2, Group B Class I, Zone 1, Group IIB Class I, Zone 2, Group IIB +
More informationReceptacle housing and cover optional malleable iron on EFS-M Series. Spring-loaded cover seats against neoprene gasket.
U-Line Factory Sealed 20 Amp Plugs and Receptacles Dead-Front Safety Construction. Choice of Aluminum or Thermoplastic Polyester Plug. Class I, Division 1 and 2 Groups B, C, D NEMA 3, 3R, 7BCD, 9FG Applications
More informationReceptacle housing and cover optional malleable iron on EFS-M Series. Spring-loaded cover seats against neoprene gasket.
U-Line Factory Sealed 20 Amp Plugs and Receptacles Dead-Front Safety Construction. Choice of Aluminum or Thermoplastic Polyester Plug. Class I, Division 1 and 2 Groups B, C, D NEMA 3, 3R, 7BCD, 9FG Applications
More informationProduct Description. Junction Boxes...V1-V23 Meter and Instrument Enclosures...V24-V33
SECTION V INDEX Product Description Page Number Junction Boxes......................................V-V2 Meter and Instrument Enclosures.......................V24-V Control Centers.....................................V4-V9
More informationAluminum and Steel Liquidtight Strain Relief Cord and Cable Connectors
Application Provide a liquidtight and strain relief termination for flexible type neoprene, hypalon, and PVC jacketed power or control cord and cable. For use in wet or dry locations sealing electrical
More information1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D
Cl. I, Div. and 2, Groups B, C, D Cl. II, Div., Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 3, 4, 4*,, Ex d IIB + H2 T, IP Explosionproof Dust-Ignitionproof Raintight Wet Locations Applications:
More information1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D
EJB Junction Boxes Cl. I, Div. and 2, Groups B, C, D Cl. II, Div., Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 3, 4, 4X*,, Ex d IIB + H2 T6, IP66 Explosionproof Dust-Ignitionproof Raintight
More informationTwist Lock - Explosion Proof - Dust Ignition Proof Receptacle Assembly
Twist Lock - Explosion Proof - Dust Ignition Proof Receptacle Assembly Part #: EPO-25A The Larson Electronics EPO-25A explosion proof power outlet provides a durable and secure weatherproof power connection
More informationSpring-loaded cover seats against neoprene gasket.
U-Line Factory Sealed 20 Amp Plugs and Receptacles Dead-Front Safety Construction. Choice of Aluminum or Thermoplastic Polyester Plug. Class I, Division 1 and 2 Groups B, C, D NEMA 3, 3R, 7BCD, 9FG Plugs
More informationCONDUIT BODIES CONDUIT BODIES. Phone:
i i Con it Bo ies allea le I on o i i I C con it cond ctors or p llin splicin Tapered threaded hu s - NPT Suita le or use in concrete Threaded LB Conduit Bodies MLB1 1/2 4-11/16 1-5/16 2-1/16 70 70.6 MLB2
More informationSpecification Grade Insulated Bushings...DA1 Specification Grade Insulated Grounding Bushings...DA2-DA4. Insulating Bushings & Couplings...
SECTION D INDEX Product Description Page Number Specification Grade Insulated Bushings.....................DA Specification Grade Insulated Grounding Bushings........DA2-DA4 Insulating Bushings & Couplings.......................DA-DA6
More informationAreamaster 1000 Floodlights Integrally Ballasted W HID For hazardous locations.
A, IIB, IIC Applications Powerful, efficient weatherproof lighting for large areas such as: Pulp and paper mills Processing plants Chemical plants Oil refineries Foundries Storage areas Waste and sewage
More informationGeneral Cable Support Information
General Cable Support Information Applications Used to support cables in vertical raceways or risers. Relieves the strain that would be placed on terminations, the interior of panels, or other devices
More informationIndustrial Areamaster LED Flood/High Bay Luminaires For Ordinary Locations. 250 W, 400 W, 750 W HID Light Level Equivalent
NEC/CEC: Type 3R, 4X IP66, IP67 Suitable for use in Wet Locations Marine Outside Type (Salt Water) Applications Powerful, efficient weatherproof lighting for applications such as: Security lighting Production
More informationJunction Boxes Hazardous and Non-Hazardous
Junction Boxes Hazardous and Non-Hazardous Description Page No. Application/Selection 112 Boxes Flush EGJ Series 19 WJBF Recessed Sidewalk Cover Series 116 Service Station EGJ Series 19 GUA Series 17 GUP
More informationDivision 2 Contender Series Factory Sealed Control Stations
NEMA 3, 3R, 4, 4X, 12 IP66 Applications For use in washdown areas and other damp, wet and highly corrosive areas. Push buttons and selector switches are used in conjunction with contactors or magnetic
More informationD2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant
Applications Protection and control of electrical equipment and circuits such as lighting and heat tracing in hazardous locations or in damp, wet or corrosive conditions. D2P Series designed for use in
More informationRigid/Aluminum Conduit Bodies, Gaskets and Covers
Rigid/luminum Conduit odies, Gaskets and Covers Conduit odies, Covers and Gaskets Weatherproof oxes and Covers pplications Junction for branch conduits Series bodies for Rigid and IMC conduit maintain
More informationEnclosures. Section E
Enclosures Section E Enclosures and junction boxes built and configured to meet the requirements of the most demanding hazardous areas and industrial environmental applications across the globe. E Enclosures
More informationAreamaster LED Flood/High Bay Luminaires
Applications Typical applications include: Pulp and paper mills Processing plants Chemical plants Oil refineries Foundries Storage areas Waste and sewage treatment Parking garages Other areas where dust,
More informationXP Series Pre-Wired Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof System
NEC/ Applications Protection and control of electrical apparatus and circuits in hazardous environments, either indoor or outdoor. Designed for Class I, Division 2 areas where flammable gases or vapors
More informationNon-Metallic, Armored Cable, and Flexible Metallic Conduit Fittings
Non-Metallic Sheathed Cable and Portable Cord Connectors Non-Metallic Sheathed Cable Connectors Armored Cable and Flexible Connectors Armored Cable and Flexible Connectors Armored, Metal Clad, and Non-Metallic
More informationW-Series Junction Boxes
W-Series Junction Boxes Application and Selection Junction boxes, designed for hazardous and non-hazardous locations, are used in a variety of industries to perform the following functions: As a pull box
More informationApplications. Illustrated Features
Applications For use in locations where a high degree of corrosion resistance is required. FR Series: For use in areas where high humidity or water vapor are present Typical uses include meat- or food-processing
More informationAreamaster 100 Wide-Beam Floodlights 70 W, 100 W, 150 W HPS; 70 W, 100 W, 150 PSMH For general, marine and hazardous locations.
Areamaster 100 Wide-Beam Floodlights NEC CEC V Class II, Divisions I and 2, Groups E, F, G V Class III Applications Highly efficient, all-weather flood-lighting for lower wattage service. Well suited for:
More informationCable Supports. Requirements for Cable Supports in the National Electrical Code reads as follows:
QA1 General Information are used to support cables in vertical raceways or risers. Cable supports relieve the strain that would be placed on terminations, the interior of panels, or other devices to which
More informationHID/FLOODLIGHT: NEC/CEC EXPLOSIONPROOF. Applications. Options
Applications UL Listed for Outside Type (Salt Water). Ideal in Class I, Division 1 and 2 installations in refineries, in pipeline transportation facilities, at drilling rigs and in production facilities
More informationW Series Cast Junction Box Options Boxes Available for Raintight, Watertight, or Submersible Applications
W Series Cast Junction Box Options Boxes Available for Raintight, Watertight, or Submersible Applications This table shows the optional items available on the different types of enclosures shown in this
More informationAreamaster LED Flood/High Bay Luminaires For Hazardous Locations. 250 W, 400 W, 750 W, 1000 W HID Light Level Equivalent
Class I, Division 2, Groups A, B, C, D Class I, Zone 2 Group IIC Class II, Division 1, Groups E, F, G Class II Division 2, Groups F, G Class III Simultaneous Exposure Type 3R, 4, 4X IP66/67 Applications
More informationPowertite Series Pin and Sleeve Plugs, Connectors and Receptacles
Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles Applications Designed to supply power to portable or fixed electrical equipment such as motor generator units, welders, pumps, compressors,
More informationBulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide
F Fixed-Depth Flange-Mounted Disconnect Switches Selection Guide F Fixed-Depth Flange-Mounted Disconnect Switches Product Cat. No. 1494F-N Disconnect Switch with Cat. No. 1494F-F Fuse Block Adapter Plate
More informationCommercial Products. New Products in the Commercial Products Product Line
Commercial Products Section A complete solution combining reliability and expertise in every product, providing you with labor and maintenance savings, simplified installation, and improved productivity
More informationNEC DBR Receptacle: Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG
EBR/DBR 30, 60, 100 and 150 Amp Series Receptacles With Disconnect Switch or Circuit Breaker. Weatherproof Spring Cover. Explosionproof, Dust-Ignitionproof 600 Vac Max. 250 Vdc Max. NEC EBR Receptacle:
More informationRigid Metal Conduit, IMC or EMT K-Clamps
65178 Rigid Metal Conduit, IMC or EMT K-Clamps Wt. Lbs. Std. Catalog No. Size (In.) Per 100 Pkg. Right Angle Type Right Angle Type Hot Dip/Mechanically Galvanized* For Rigid, IMC, EMT PC-50RA 1/2 37.0
More informationConductor Size 18 TO 8 AWG, 6 TO 0 AWG, 2/0 TO 4/0 AWG, 4/0 AWG TO 750 MCM (ALUMINUM/COPPER CLAD, ALUMINUM/COPPER)
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 DR20022 Cable Support Appleton/Oz Gedney Catalog Number Manufacturer Description Weight per unit Product Category DR20022
More informationCEC: Class I, Division 1 and 2, Groups B, C, D Class II, Division 1 and 2, Groups E, F, G Class III Type 4X Exd IIB + H 2
Integrally Ballasted. 50 W, 70 W, 00 W, 50 W HPS; 75 W PSMH. 75 W MH. Medium Base. For Use with Threaded Metal Conduit. Applications For use in chemical and petrochemical plants, such as manufacturers
More informationALUMINUM OUTLET BODIES
KILLARK GEB SERIES ALUMINUM OUTLET BODIES * Class I, one I, Groups IIC, IIB, IIA Type 4X Applications GEB series conduit boxes are installed in conduit systems within hazardous areas to: Protect conductors
More informationCondulet Conduit Bodies and Outlet Boxes Hazardous
Condulet Conduit Bodies and Outlet Boxes Hazardous 4F Description Page No. Application/Selection 48, 49 Lubricants HTL 59 STL 59 Conduit Bodies & Outlet Boxes Cylindrical EKC 57 90 Elbow LBH 58 LBY 58
More informationExplosion Proof & Hazardous Area Junction Boxes
CSA - Class I Div. 1 - Groups C & D * CSA - Class I Zone 1 - Groups IIA, IIB * * Applies to GUI boxes only Explosion Proof & Hazardous Area Junction Boxes Features: Heavy-duty copper free (below 0.04%)
More informationNEC/CEC CLASS/ZONE RATED HAZARDOUS LOCATION CIRCUIT BREAKERS. Application
- and 3-Pole, Non-Interchangeable Trip. Bolted Enclosure Type. Class I, Division 1 and, Groups B, C, D Class II, Division 1 and, Groups E, F, G Distribution Equipment NEC/CEC CLASS/ZONE RATED HAZARDOUS
More informationUse the following standards for system design and performance requirements.
Design The Electrical Motor Design Guidelines contains design criteria and specifications used in the procurement of electrical 3-phase AC induction motors. Table of Contents 1. Introduction 2. Design
More informationLIGHTING: EXPLOSIONPROOF FLOODLIGHT. Applications. Options
Code Master 2 HID Factory Sealed Floodlights NEC: Class 1, Division 1 and 2, Groups C, D Marine Type Electric Fixtures Outside Type (Salt Water) CEC: V Class I, Division 1 and 2, Groups B, C, D Class II,
More informationEPOXY POWDER COATED COPPER FREE ALUMINUM
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AJA510 Alum MTG Unilet Appleton/Oz Gedney Catalog Number Manufacturer Description Weight per unit Product Category Features
More informationDISTRIBUTION EQUIPMENT: NEC/CEC HAZARDOUS LOCATION SWITCHES. Application
- and 3-Pole, Non-Interchangeable Trip. Bolted Enclosure Type. Class I, Division 1 and, Groups B, C, D Class II, Division 1 and, Groups E, F, G Application Explosionproof circuit breaker enclosures are
More informationMyers Hubs. Standard Finishes: Aluminum: Natural Zinc: Natural Stainless: Natural
Applications: Myers Hubs are used in the termination of electrical circuits through wall of the enclosure Designed for use indoors or outdoors with rigid conduit and IMC Ideal for pharmaceutical, chemical
More informationLiquid Tight. Liquid Tight Connectors Reusable Fittings. Straight Connectors. Straight Connectors with Insulated Throat
Liquid Tight Connectors Reusable Fittings Industrial specification grade, screw machined steel, zinc plated UL Rated Liquid Tight Includes sealing washer Bonds conduit to box or enclosure Corrosion resistant
More informationWire Mesh Safety Grips
Pulling Grips PS Series S PS Series grips feature a double weave of galvanized steel strands for greater strength and added mesh contact with the cable. Leviton Double Weave Pulling Grips are designed
More informationYOUR FULL LINE SOURCE FOR PVC ELECTRICAL PRODUCT
CANTEX INC. 301 Commerce Ste 2700 Fort Worth, Texas 76102 817-215-7000 Fax: 817-215-7001 Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes YOUR FULL
More informationProduct Specification Guide Expansion and Deflection Couplings. SECTION Raceway and Boxes for Electrical Systems
Product Specification Guide Expansion and Deflection Couplings SECTION 26 05 33 Raceway and Boxes for Electrical Systems Specifier Notes: Delete any information below in Parts 1, 2 or 3 which is not required
More informationPowertite Series Pin and Sleeve Plugs, Connectors and Receptacles
Applications Designed to supply power to portable or fixed electrical equipment such as motor generator units, welders, pumps, compressors, cellular relay stations, and similar apparatus. Ideal for use
More informationP-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant
P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant Applications Protection and control of electrical equipment and circuits
More informationPLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION
Explosionproof, Dust-Ignitionproof With Disconnect Switch or Circuit Breaker. Weatherproof Spring Cover. 600 Vac Max. 250 Vdc Max. Applications Locations where receptacles are used with stationary or portable
More informationCP Myers Hubs. Class I, Div. 2 Class II, Div. 1 and 2 Class III. when installed in accordance with the NEC. Features. Material.
Myers Hubs Class I, Div. 2 Class II, Div. 1 and 2 Class III when installed in accordance with the NEC. CP Myers Scru-tite TM and Ground hub are used in the termination of electrical circuits through wall
More informationELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY
EDSC210 -Way Switch Cooper Crouse-Hinds Catalog Number Manufacturer Description Weight per unit Product Category Features Box Type Contact Configuration Current Rating Voltage Rating Material, Color, and
More informationEDS / EFS Series Control Stations
EDS / EFS Series Fully Assembled EFS and EDS Factory Sealed Devices Cl. I, Div. & 2, Groups B*, C, D Cl. II, Div., Groups E, F, G NEMA, 7B*CD, 9EFG Applications: Factory sealed enclosures are installed
More informationBulletin 1494V Variable-Depth Flange-Mounted Circuit Breaker Operating Mechanism
Bulletin V Variable-Depth Flange-Mounted Circuit Breakers Product Overview/Product Selection Circuit Breaker Kits Cat. No. V-C Circuit Breaker Kit (Shown without handle and connecting rod) Bulletin V Variable-Depth
More informationFACTORY SEALED CONTROLS - INTRODUCTION
FACTORY SEALED - INTRODUCTION Contact Factory for other certification details D2CU Factory Sealed Contact Block Applications Seal-XM Factory Sealed push button stations, selector switches, pilot lights
More informationMipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service
No One Does It Like Mipco Mipco Interlocked Reefer Power Outlets are used extensively in port terminals and shipboard applications to provide a safe, watertight electrical connection for refrigerated containers.
More informationELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY
EDS2274 Pos D.E. Selector Switch Cooper Crouse-Hinds Catalog Number Manufacturer Description Weight per unit Product Category Features Box Type SINGLE GANG Contact Configuration 4NO-4NC Number of Circuits
More informationCorrosion Protection for Electrical Conduit and Fittings
Easy access for pulling, splicing, mounting and maintenance! 3 4" LB Form 8 conduit body and cover 2 1 2" LB Form 8 conduit body and cover OCAL-BLUE Double-Coat Conduit Bodies With OCAL-BLUE Double-Coat
More informationEDS / EFS Series Control Stations
EDS / EFS Series Control Stations Fully Assembled EFS and EDS Factory Sealed Devices Cl. I, Div. & 2, Groups B*, C, D Cl. II, Div., Groups E, F, G NEMA, 7B*CD, 9EFG Applications: Factory sealed enclosures
More informationStandard Finishes Receptacles: epoxy powder coat Cord connector housings and caps: epoxy powder coat
U-Line Factory Sealed 15 and 20 Amp Plugs and Receptacles V Applications Locations where receptacles are used with stationary or portable electrically operated devices such as: Lighting systems Conveyors
More informationDevice Utility Finished FS Gang Conduit Bodies and Covers KO Seals Reducing Washers
Device Utility Finished FS Gang Conduit Bodies and Covers KO Seals Reducing Washers Mulberry Outlet Box Covers New in this catalog: A full line of die-cast, powder painted conduit bodies: 1/2-4, threaded
More informationArktite Circuit Breaking CPS Receptacles and CPP Plugs Delayed Action Factory Sealed
Arktite Circuit Breaking CPS Application: CPS receptacles, angle and straight types, and CPP plugs are used: with portable electrically operated devices such as motor-generator sets, compressors, conveyors,
More informationPowertite Series Pin and Sleeve Plugs, Connectors and Receptacles
Applications Designed to supply power to portable or fixed electrical equipment such as motor generator units, welders, pumps, compressors, cellular relay stations, and similar apparatus. Ideal for use
More informationCable Connectors & Conduit Sealing Bushings
RA1 Cable Terminators General Information Purpose: Cable Terminators and Sealing Fittings are used on conduit ends and cable ends to effectively seal the cable and conduit. Where Installed: Wherever the
More informationProduct Information. Receptacles and Plugs: Explosionproof For use with Threaded Metal Conduit. MD2SR Interlocked Switched Receptacle
L02-L12 01 Receptacles and Plugs: Explosionproof For use with Threaded Metal Conduit. Applications Locations where receptacle is used with stationary or portable electrically operated devices such as lighting
More informationWire Mesh Safety Grips
Straight Male 90 Male Straight Female L7901 L7915 L7951 Liquid-Tight Grips U* R* Liquid-Tight Grips are woven stainless steel mesh with an anodized aluminum body for corrosion-resistance. They are used
More informationA/C Disconnects. Only $7.99 each In cases of (6) B222-60NF In cases of (10)
A/C Disconnects 60 amps Non-fused. 240v A.C. Single Phase. UL Listed Three piece construction that opens up mounting and wiring areas, reduces installation time. Terminals approved for 60*C and 75*C wire.
More informationFACTORY SEALED CONTROLS - INTRODUCTION
FACTORY SEALED - INTRODUCTION Contact Factory for other certification details D2CU Factory Sealed Contact Block Applications Seal-XM Factory Sealed push button stations, selector switches, pilot lights
More informationFV Series Nonmetallic Fluorescent Luminaires For Hazardous and Adverse Locations
Applications For use in hazardous locations defined by the NEC and CEC as Class I, Division 2, Groups A, B, C and D; Class II, Division 2, Groups F and G; Marine Outdoor Salt Water; UL1598A and. As well
More informationEDS / EFS Series Control Stations
EDS / EFS Series Control Stations Fully Assembled EFS and EDS Factory Sealed Devices Cl. I, Div. &, Groups B*, C, D Cl. II, Div., Groups E, F, G Cl. II, Div., Groups F, G NEMA, 7B*CD, 9EFG Applications:
More informationConduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes
CANTEX INC. 301 Commerce Ste 2700 Fort Worth, Texas 76102 817-215-7000 Fax: 817-215-7001 Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes YOUR FULL
More informationCode Master Incandescent Factory Sealed Luminaires Explosionproof, Dust-Ignitionproof For use with threaded metal conduit.
Applications For use in hazardous locations such as plants where plastics, paints, thinners and petrochemicals are manufactured. For use in chemical and petrochemical plants, such as manufacturers of plastics,
More informationHazardous Duty Applications
Hazardous Location Hazardous Duty Plugs, Receptacles and Interlocks Hazardous Duty Plugs, Receptacles and Interlocks Hazardous Duty Applications Russellstoll Hazardous Duty Plugs, Receptacles and Interlocks
More informationApplications. Housings: copperfree (4/10 of 1%) aluminum Shaft, bushings and exposed hardware: stainless steel Standard Finishes
AE Threaded Combination and Non-Combination Full Motor Starters Units Provide Disconnecting Means and Undervoltage, Circuit and Motor Running Protection. Class I, Division and, Groups C, D Class II, Division
More informationHeating Cable. Description
203312 Single Entry Connection Box NEMA 4X Entry for 1 Cable 3/4 Conduit Hub Opening Multiple Entry Connection Box NEMA 4X Entry for up to 3 Cables Power or Tee Connection 3/4 Conduit Hub Opening End Seal
More information