Bulletin 1494V Variable-Depth Flange-Mounted Circuit Breaker Operating Mechanism
|
|
- Katrina Carroll
- 6 years ago
- Views:
Transcription
1 Bulletin V Variable-Depth Flange-Mounted Circuit Breakers Product Overview/Product Selection Circuit Breaker Kits Cat. No. V-C Circuit Breaker Kit (Shown without handle and connecting rod) Bulletin V Variable-Depth Flange-Mounted Circuit Breaker Operating Mechanism Circuit breaker operating mechanisms for use with and circuit breakers in enclosures up to in. deep. -pole, V AC rating,, and A circuit breaker frame sizes Complete kits with accessories Field installed Can be used with enclosure Types, R,, X, and Can be field installed on a right-flanged or left-flanged enclosure Lockable handle Table of Contents... - Specifications... - Approximate Dimensions... - Standards Compliance UL CSA C., No. Certifications UL Recognized(File No. E, Guide No. NLDX) CSA Certified (File No. LR) Circuit Breaker Kits Optional accessories listed below can be added to the circuit breaker kits to create () cat. no. Example: Cat. No. V-C-A-B-F Circuit Breaker Kits include: Connecting rod Metal handle Circuit breaker operating mechanism (circuit breaker to be supplied by customer) -Pole Circuit Breaker Operating Mechanism Brand Frame Size [A] Frame Designation Cat. No. U-H (MCCB), M-H (MPCB + MCP) EG, HMCPE M-I (MPCB + MCP), U-I (MCCB) EHD, FD, FDB, FDC, HFD, HMCP U- (MCCB), M- (MPCB + MCP) G V-C V-C V-C D, DB, DC, HD, HMCP V-C Kit U-K (MCCB), M-K (MPCB + MCP) KD, KDB, KDC, HKD, HMCP V-C Bulletin V Kit Field Installed Circuit Breaker Frame Size [A] Description Suffix Code Longer Connecting Rod (-/ -/ in.) A A A A A Disconnect Handle Stainless Steel B A A A A Disconnect Handle Non-Metallic C A A A A N.O. F A A A A Auxiliary Contact includes adapter kit N.O. FF A A A A N.C. G A A A A N.C. GG A A A A Metal handle provided as standard. For stainless steel handle, select suffix code B. For non-metallic handle, select suffix code C. Publication A-CAA-EN-P -
2 Bulletin V Variable-Depth Flange-Mounted Circuit Breakers Product Selection Circuit Breaker Components Components Circuit Breaker Operating Mechanism The mechanism listed must be combined with a connecting rod, operating handle, and a circuit breaker (supplied by customer) to obtain a functional device. -Pole Circuit Breaker Operating Mechanism Brand Frame Size [A] Frame Designation Cat. No. U-H (MCCB), M-H (MPCB + MCP) EG, HMCPE U-I (MCCB) EHD, FD, FDB, FDC, HFD, HMCP, M-I (MPCB + MCP) U- (MCCB), M- (MPCB + MCP) G V-M V-M V-M D, DB, DC, HD, HMCP V-M U-K (MCCB), M-K (MPCB + MCP) KD, KDB, KDC, HKD, HMCP U-L (MCCB, MPCP, MCP) Circuit breakers to be provided by customer. Connecting Rods Approximate dimensions are in inches (millimeters). Approximate dimensions are not intended for manufacturing purposes. Circuit Breaker Frame Size [A],,, Operating Handle V-M Enclosure Depth Minimum Maximum Cat. No. -/ () -/ () V-RA -/ () -/ () V-RA Handle Type Description Mounting Circuit Breaker Frame Size [A] Operating Handle Cat. No. Type, R,, X, Nonmetallic Right or Left Flange,,, F-P Type, R,, Painted Metal Right or Left Flange,,, F-M Type, X Stainless Steel Right or Left Flange,,, F-S - Publication A-CAA-EN-P
3 Bulletin Auxiliary Contacts Auxiliary Contacts ( A Disconnect Switch only) Description For Use With Cat. No. N.O. Contact N.O. Contact (low-level switching) C, F, V, and G ( A) Disconnect Switches -N -NX N.C. Contact -N D, V ( N.C. Contact (low-level A Frame) Circuit Breakers switching) -NX N.O. Contact Cat. No. -A Cat. No. -B N.C. Contact C, G, and V Disconnect Switches A only -B Auxiliary Contact Adapter Kit For A -N Disconnect Switches Cat. No. -N Cat. No. -N Cat. No. -N Cat. No. -N Cat. No. -N Cat. No. -N Auxiliary Contact Adapter Kit For Disconnect Switches with Left-Hand Mechanism Auxiliary Contact Adapter Kit For Circuit Breakers Electrical Interlocks Electrical Interlock Adapter Kit A Disconnect Switch A Disconnect Switch A and A Frame, A, A Frame, A Frame, A Frame, A, A, A Frame N.O. and N.C. early N.O. and N.C. early N.O. and N.C. early N.O. and N.C. early N.O. and N.C. early N.O. and N.C. early N.O. and N.C. early N.O. and N.C. early N.O. and N.C. early N.O. and N.C. early A DPDT early break (for A, Type & R only) A DPDT early break (for A, Type ) A DPDT early break (for all A, A, & A, Type, R, and ) A Disconnect Switch V Disconnect Switch with Left-Hand Mechanism, A V Disconnect Switch with Left-Hand Mechanism, A D, V Circuit Breakers -A -N -N -N V Circuit Breaker -N D Circuit Breaker -N D Circuit Breaker -N D Circuit Breaker -N C, G & V Disconnect Switches with Left-/Right-Hand Mechanism, A & Right-Hand Mechanism, A C, G, & V Disconnect Switch with Right-Hand Mechanism, A, A C and V Disconnect Switch with Left-Hand Mechanism, A V Disconnect Switch with Left-Hand Mechanism, A V Disconnect Switch with Left-Hand Mechanism, A H Safety Switch C, G, V Disconnect Switch Requires an adapter kit on new installations. One adapter kit enables up to two auxiliary contacts to be installed. Additional adapter kit (Cat. No. -N) required for installation on A switch. -N -N -N -N -N -N -N -N -N -N -N -N -N - Publication A-CAA-EN-P
4 Bulletin Lug Connectors ( per package) Disconnect Size [A] Description For Use With Cat. No. Wire Size # AWG Wire # AWG Wire R-N # / AWG Wire C, F, G, and R-N V Disconnect # / AWG Wire Switches R-N # MCM Wire (oversized) -LF () of #/ MCM Wire R-N # AWG MCM Wire (oversized) R-N () of #/ MCM Wire R-N () of #/ MCM Wire -N or -R R-N Cat. No. R-N () of # MCM Wire A fuse blocks R-N Ground Connectors Ground Lug Kits A C, F, G, and -GR V Disconnect A Switches -GR A -GR, A H & HL Safety -GR Cat. No. -GR, A Switches -GR Neutral Kits /V AC Fusible (Type & R) -NK /V AC Non-Fusible (Type & R) -NK /V AC Fusible & Non-Fusible (Type ) -NK /V AC Fusible & Non-Fusible (Type & R) -NK /V AC Fusible (Type ) -NK /V AC Non-Fusible (Type ) H Safety Switches -NK /V AC Fusible (Type & R) -NK /V AC Non-Fusible (Type, R, and ) -NK /V AC Fusible (Type ) -NK /V AC Fusible & Non-Fusible (Type & R) -NK /V AC Fusible & Non-Fusible (Type ) -NK Phase Barrier Kits Disconnect Size [A], C, F, G, F-PH V F-PH F-PH F-PH All terminals of the A switches are furnished with self-lifting pressure plate connectors as standard. Each kits contains () lugs. Each kit contains () lugs. Publication A-CAA-EN-P -
5 Bulletin Fuse Clips ( per package) Fuse Class H R Description For Use With Cat. No. V Fuse Clip Rating [A] V -N C, F, G, and V Disconnect Switches -N -N -N -N -N C, F, G, and V Disconnect Switches -N C, F, G, and V Disconnect Switches -N C, F, G, and V Disconnect Switches -N C, F, G, and V Disconnect Switches -N C, F, G, and V Disconnect Switches -N V-FS Fuse Blocks -N -N C, F, G, and -N V Disconnect Switches -N -N -N H, R Fuse Blocks Class R Fuse Clip Kits V AC (Type, R, ) -N V AC (Type, R) -N V AC (Type ) -N V AC (Type, R, ) H Safety Switches -N V AC (Type, R, and ) -N /V AC (Type & R) -N /V AC (Type ) -N /V AC (Type, R, and ) -N V AC (Type & R) -N V AC (Type & R) -N HL Safety Switches V AC (Type & R) -N V AC (Type & R) -N Included with Bulletin separate mounted fuse blocks. One fuse block kit per pole required. Fuse clips not required; fuse bolts directly to terminal. - Publication A-CAA-EN-P
6 Bulletin Protective Fuse Covers (for use with Bul. C, F, G, and V disconnect switches) Fuse Clip Rating [A] Switch Rating [A] Fuse Class V V Cat. No. H, R H, R -N H, R H, R -N H, R -N H,, R -N H,, R -N H,, R -N H,, R -N -N H,, R -N Protective Line Covers (for use with Bul. C, F, G, and V disconnect switches),, -N -N -N -N Terminal Lug Adapter Kit allows two wires (maximum AWG) to be installed on the line side or load side (for use with Bul. C, F, G, and V disconnect switches) R-N R-N R-N, R-N Switch with right-hand mechanism. Switch with left-hand mechanism. Used with Bulletin -Nand -R on Bulletin V/C/G. Publication A-CAA-EN-P -
7 Bulletin Description For Use With Cat. No. Defeater Bracket Extension Kit For use with operating handles that do not align properly with the door catch or door hardware on enclosures with a rolled lip flange construction. All F and V Handles (except V-R and V-R) V-H Channel Support Kits For use to prevent flexing of the operating handle mounting surface. This is especially useful when the operating handle is mounted on a channel in a multi-door enclosure. A Switches Applies only to Operating Handle Cat. Nos. F-P, M, and S. V-H Packaged in quantities of. Conduit Hubs (for Type R enclosures) A, A, A. mm (/ in.) hub -N. mm ( in.) hub A, A -N. mm (-/ in.) hub A H Safety Switches -N. mm (-/ in.) hub A -N. mm ( in.) hub -N. mm (-/ in.) hub A -N Non-Metallic Conduit Connectors / in. (. mm) A -N / in. ( mm) A -N in. (. mm) A -N -/ in. (. mm) A -N -/ in. (. mm) A -N in. (. mm) A -N -/ in. (. mm) A -N in. (. mm) A -N G Disconnect Switches Grounding Adapters # AWG, / in. (. mm) A -N # AWG, / in. ( mm) A -N # AWG, in. (. mm) A -N # AWG, -/ in. (. mm) A -N # / AWG, -/ in. (. mm) A -N # / AWG, in. (. mm) A -N # / AWG, -/ in. (. mm) A -N # / AWG, in. (. mm) A -N - Publication A-CAA-EN-P
8 Bulletin Cat. No. V-L Decription For Use With Cat. No. Type Door Hardware Kit Includes: handle, cam, defeater actuator lever, rollers, and shims Enclosure Height less than in. ( mm) Top and Side (Right Hand) Top and Side (Left Hand) Enclosure Height in. ( mm) Top and Side (Right Hand) Bottom Top and Side (Left Hand) Bottom Enclosure Height greater than in. ( mm) C, All V V-L V-LL V-L and V-L V-LL and V-L V-L Top, Side, and Bottom (Right Hand) Cat. No. V-L Cat. No. V-L Top, Side, and Bottom (Left Hand) V-LL Type Door Hardware Kit Includes: Handle, cam, defeater actuator lever, rollers, and shims Cat. No. F-L and F-L Enclosure Height less than in. ( mm) Top and Side (Right Hand) Top and Bottom (Right Hand) Enclosure Height in. ( mm) Top and Bottom (Right Hand) Side Enclosure Height greater than in. ( mm) Top, Side, and Bottom (Right Hand) Master Door Interlock Kits Interlock kits are designed to provide interlocking between the master and auxiliary doors of the same enclosure and for use with Cat. Nos. F-L hardware kits or Cat. No. V-L hardware kits. Specify one master door kit and as many auxiliary door kits as necessary ( maximum). Connecting bars must be supplied by user. F, D C, F, D, V F-L F-L F-L and F-L F-L F-N Cat. No. F-N Auxiliary Door Interlock Kit F-N Door hardware kit does not include rectangular connecting bars (/ x / in.). To be provided by customer. Door hardware kit does not include rectangular connecting bars (/ x / in.). To be provided by customer. Master door interlock kit does not include rectangular connecting bars (/ x / in.). To be provided by customer. If the Rockwell Automation door hardware kits are to be installed in a commercially available enclosure, consult the enclosure manufacturer's application data for proper kit selection. Publication A-CAA-EN-P -
9 Bulletin Specifications Bulletin C, F, G, R, V Disconnect Switches Disconnect Switch Electrical Ratings Switch Size A A A A A A Rated insulation voltage Ui (UL) IEC () V V/ Hz. V/ Hz Hp Ratings V/ Hz UL/CSA/NEMA V DC Ratings IEC Applications Continuous Current Maximum kw (AC) V AC V DC V/ Hz V/ Hz V/ Hz. Auxiliary Contact Electical Ratings NEMA/EEMAC B, P Ui V I th A V IEC Ratings V ACII U x V V Low level switching V DC Mechanical Degree of protection Non-metallic Type, R,, X,, Operating Painted Type, R,, handles Stainless steel Type, X Mechanical life (Typical) operations ( A) operations ( A) Switching frequency (operations/hr),,, and A sizes max. and A sizes max. Environmental Temperature Operating - + C (- + F) Storage - + C (- + F) Altitude (per IEC -) m per IEC - Relative Humidity (per IEC -) % at C ( F) and % at C ( F) Design Specification/Test Requirements Dielectric strength V for minute Electrical life operations at rated current A: unfused Short Circuit Withstand Capability A: with Class H fuses A: with Class or Class R fuses Construction Switch body material Phenolic Contact material Copper, tin-plated Terminals A A A A A A All wire rated C ( F) or higher must be sized per the local Electric Code for C ( F) wire. Conductor Size (mm) A A A A A A A A Recommended Torque A A A A Switches, Mechanisms, and Accessory Kits # - screw and self-lifting pressure plate / in. - screw-lug, copper / in. - screw-lug, copper / in. - screw-lug, copper / in. - screw-lug, copper / in. - screw-lug, copper # AWG (. mm) # AWG (. mm) # / AWG ( mm) # / AWG ( mm) of #/ AWG MCM ( per lug) of mm MCM or () # AWG MCM of #/ AWG MCM ( per lug) of mm MCM or () # AWG MCM Conductor into Lug lb in lb in lb in lb in lb in lb in Zinc-plated steel, RoHS Compliant finish I e Lug to Terminal lb in lb in lb in lb in lb in lb in A A. A. A - Publication A-CAA-EN-P
10 Bulletin Approximate Dimensions Approximate dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Bulletin V Circuit Breaker Auxiliary (When Used) Common Industrial Flange Cut-Out Trailer Fuse Block Vertical Center Line of Operation Handle Drilling Door Provides for Wire Bending Space Disconnecting Means Enclosure Flange Operating Handle Mounting Surface Disconnect Means Mounting Surface Bulletin V A / (.) Dia Holes Vertical Center Line of Operating Handle Flange Cut-Out Center Line Operating Mechanism Square Corners or / (.) R. Bulletin V A Disconnect Switches NEMA Size [A] A -/ () -/ () -/ () -/ (.) (.) -/ (.) B Max. Min. Max. -/ () -/ () -/ (.) -/ (.) -/ (.) -/ (.) -/ () -/ () -/ () -/ (.) -/ (.) -/ (.) Approximate dimensions are for reference only. This approximate dimension will vary by fuse class and size. Approximate dimension with Class fuses. C -/ () -/ () -/ () -/ () -/ () -/ () D E F -/ (.) -/ (.) -/ (.) -/ (.) (.) (.) -/ () -/ () -/ () -/ () () -/ (.) -/ (.) -/ (.) -/ (.) -/ () -/ (.) -/ (.) Switch Mounting Hole Diameter / in. / in. / in. / in. / in. / in. Circuit Breakers Frame A U-H, M-H, EF, HMCPE A U-I, M-I EHD, FD, FDB, FDC, HFD, HMCP A U-, M- A D, DB, DC, HD, HMCP A U-K, M-K KD, KDB, KDC, HKD, HMCP A U-L A (.) -/ (.) -/ (.) Approximate dimensions are for reference only. Min. -/ (.) -/ (.) -/ (.) C Max. (.) -/ (.) -/ (.) D E F (.) () (.) -/ (.) -/ (.) -/ (.) () -/ (.) -/ (.) Publication A-CAA-EN-P -
Bulletin 1494D Fixed-Depth Flange-Mounted Circuit Breakers
Bulletin 1494D Fixed-Depth Flange-Mounted Circuit Breakers Bulletin 1494D Fixed Depth Flange Mounted Circuit Breaker Operating Mechanism Industrial rated circuit breaker operating mechansim pre-assembled
More informationBulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide
F Fixed-Depth Flange-Mounted Disconnect Switches Selection Guide F Fixed-Depth Flange-Mounted Disconnect Switches Product Cat. No. 1494F-N Disconnect Switch with Cat. No. 1494F-F Fuse Block Adapter Plate
More informationCable-Operated Disconnect Switches. Accessories
Cable-Operated Disconnect Switches Accessories Description For Use With Auxiliary Contacts 1 N.O. Contact 1494C, 1494F, 1494V, and 1494G ( 1495-N8 1 N.O. Contact (low-level switching) A) Disconnect Switches
More information600V, Non-Fusible, (3-Pole, 3 Phase)
0V, Non-Fusible, (3-Pole, 3 Phase) ulletin 1494G/1494GX1494GY Non Fusible 0 A switch ratings 0V: 3-pole, 3-phase and 6-pole, 3-phase versions versions only Type 3R/4/12 (painted metal), Type 4/4X (stainless
More informationBulletin 1494V Variable Depth Flange-Mounted Disconnect Switches. Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches
2 Bulletin 1494 NEMA Disconnect Switches Section Overview Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches Open Type, Fusible 30 600 A Open Type, Non-Fusible 30 600 A Page 2-3 Bulletin
More informationPRODUCT PROFILE VARIABLE-DEPTH, FLANGE- MOUNTED DISCONNECT SWITCHES A BULLETIN 1494V
PRODUCT PROFILE BULLETIN 1494V Rockwell Automation introduces the enhanced version of Allen-Bradley Bulletin 1494V Variable-Depth, Flange-Mounted Switches that meet industrial requirements for dependable
More informationPRODUCT PROFILE 1494C CABLE-OPERATED, FLANGE-MOUNTED DISCONNECT SWITCHES
PRODUCT PROFILE 1494C CABLE-OPERATED, FLANGE-MOUNTED DISCONNECT SWITCHES Rockwell Automation expands its new line of Allen-Bradley Bulletin 1494C Cable-Operated, -Mounted Switches that meet industrial
More informationBulletin 1494C Cable Operated Disconnect Switch Kit (400A) Installation Instructions (Cat 1494C- _ Series 2 : 400A)
Bulletin 494C Cable Operated Disconnect Switch Kit () Installation Instructions (Cat 494C- _ Series : ) ATTENTION: To prevent electrical shock, disconnect from power source before installing or servicing.
More informationBulletin 1494V Variable Depth Disconnect Switch Installation Instructions (Cat 1494V-DS400; -DSX400 - Series D)
Bulletin 494V Variable Depth Disconnect Switch Installation Instructions (Cat 494V-DS400; -DSX400 - Series D) ATTENTION: To prevent electrical shock, disconnect from power source before installing or servicing.
More informationBulletin 1494C Cable Operated Disconnect Switch Kit (600A) Installation Instructions (Cat 1494C- _ Series 2 : 600A)
Bulletin 494C Cable Operated Disconnect Switch Kit (600A) Installation Instructions (Cat 494C- _ Series : 600A) ATTENTION: To prevent electrical shock, disconnect from power source before installing or
More informationBulletin 1494V Variable Depth, Flange Operated Disconnect Switch Kits for 400 and 600 Amperes (Series A) Switches
Bulletin 494V Variable Depth, Flange Operated Disconnect Switch Kits for and Amperes (Series A) Switches ATTENTION: To prevent electrical shock, disconnect from power source before installing or servicing.
More informationUL Enclosed Disconnect Switches (Fused and Non-Fused)
Product Selection UL Enclosed Disconnect Switches (Fused and Non-Fused) Catalog Number Explanation 194R-K Non-Metallic Enclosure UL Type 3/4/4X, IP66 194R-F Painted Steel Enclosure UL Type 3/4/12, IP66
More informationBulletin 109 IEC Non-Reversing Starters. Product Overview/Product Selection. Table of Contents
Bulletin IEC Non-Reversing Starters Product Overview/Product Selection Cat. No. -CABAF--R-P IP (Type ) Metal Enclosure with Lift-off Cover Bulletin IEC Non-Reversing Starters Impact-resistant molded enclosures
More informationProduct Specification Sheet #3LD2.1
Product Specification Sheet #3LD2.1 Enclosed Non-Fusible Rotary Disconnect Switch 16 30 Amp, Type 12K Industrial and Type 4X Non-Metallic Enclosures General Information and Horsepower Ratings Shipping
More informationUL/CSA Non-fused Disconnect Switches
Product Selection UL/CSA Non-fused Disconnect Switches Cat. No. 194R-N30-1753 Cat. No. 194R-J100-1753 Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.
More informationCat. No. 194R-J Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.
Product Selection UL/CSA Fused Disconnect Switches Cat. No. 194R-J30-1753 Cat. No. 194R-J100-1753 Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.
More informationFor Variable Depth Disconnect Devices And For Flexible Cable Disconnect Devices
For Variable Depth Disconnect Devices And For Flexible Cable Disconnect Devices In Hoffman Bulletin A19 (painted steel) Or Hoffman Bulletin A19S (stainless steel) Wall Mounted Disconnect Enclosures Rev.
More information1494U Visible-Blade Disconnect Switch
Selection Guide 1494U Visible-Blade Disconnect Switch Bulletin Number 1494U What s Inside Contents Page 1494U Disconnect Switch Components 3 1494U Disconnect Switch Accessories 4 1494U Disconnect Switch
More informationTable of Contents. Quick Installation Guide 2 - Disconnect Switch Installation - Disconnect Handle Installation - Cutting Connecting Rod
ulletin 494V Variable Depth Disconnect Switch Installation Instructions (Cat 494V-DS30; -DSX30 - Series D; 494V-DS; -DSX - Series D) (Cat 494V-DS00; -DSX00 - Series D; 494V-DS00; -DSX00 - Series D) TTENTION:
More informationSIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A
Non-fusible disconnect switches SIRCO UL98 Non-fusible switches standards UL and CSA sirco-ul_022_b_1_cat The solution for > Power distribution sirco_093_b_1_cat SIRCO 3 x 200 A Strong points > Reliability
More informationFor Variable Depth Disconnect Devices And For Flexible Cable Disconnect Devices
For Variable Depth Disconnect Devices And For Flexible Cable Disconnect Devices In Hoffman Bulletin CWY (painted steel) Or Hoffman Bulletin CWSD (stainless steel) CONCEPT Wall Mounted Disconnect Enclosures
More informationSIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A
The solution for Load break switches sirco-ul_022_b_1_cat > Power distribution. Strong points sirco_093_b_1_cat SIRCO 3 x 200 A > Reliability. > Safety of property and personnel. > Simplicity. > Easy assembling.
More informationBulletin 194R TABLE OF CONTENTS Bulletin 194R IEC Fused and Non-Fused Disconnects
4 Bulletin 194R TABLE OF CONTENTS Bulletin 194R 20 A 400 A Sizes Open or Enclosed Switches d Switch Versions: BS88 DIN CSA HRCII-C CSA HRCI-J UL Class J UL Class CC Non-d Switches Operating Handle Ingress
More informationAE Wallmount FMD Enclosures AE Wallmount Carbon Steel Cabinets
FMD ENCLOSURES AE Wallmount FMD Enclosures AE Wallmount Carbon Steel Cabinets Superior in design, Rittal's AE flange mounted disconnect enclosures have fewer moving parts, which reduces assembly and installation
More informationDisconnect Switch and Circuit Breaker Mechanism Specifications Bulletin Number 1494
Technical ata isconnect Switch and ircuit reaker Mechanism Specifications ulletin Number 1494 Topic Page 1494U isconnect Switch Specifications 2 1494, 1494F, 1494G, 1494R, 1494V isconnect Switch Specifications
More informationBig performance in a small package
Series 11 Fusible up to 800A & Non fusible Disconnect Switches up to 1200 Amps Suitable as a U98 Service Entrance Disconnecting Means TIP! To learn the basic differences between control, load and fusible
More informationInstallation Instructions
Installation Instructions Bulletin 1494V Variable Depth, Flange Operated Circuit Breaker Operating Mechanisms For use with Circuit Breakers 140G-G, 140MG-G, 140G-H, 140MG-H, 140G-I, 140MG-I, 140G-J, 140MG-J,
More informationEnclosed Rotary Switch Product Specification Sheets Table of Contents
Enclosed Rotary Switch Product Specification Sheets Table of Contents Catalog No. Sheet No. Order No. SSSS-ENRSW-1005 HNF3020CJ HNF3020CJE HNF3030CJ HNF3030CJE HNF3030CX HNF3060CJ HNF3060CJE HNF3060CX
More informationDisconnect Enclosures
Type 12 Heavy-Duty Single & Multi-Door Data Sheet pplication Houses electrical controls and equipment Protects against circulating dust, falling dirt and dripping non-corrosive liquids Standards UL 508
More informationBulletin 190-M Compact Starters. Selection Guide
Bulletin 190-M Selection Guide Bulletin 190-M Selection Guide 3 Bulletin 190-M Compact Design to 45mm Wide Common Adapter for Panel or DIN Rail Mounting Pre-Wired Assembly All Control Terminations Located
More informationMulti-Pak Group Control
Multi-Pak Grouping.1 Product....................................... Application.................................... Features Enclosures........................................... V-T-2 V-T-2 V-T-2 Feeder
More informationCertifications UL Listed (File No. E 14841, Guide NLRV; File No. E 47426, Guide WHTY) CSA Certified (File No. LR1234) CE
Bulletin R Overview Bulletin R Next Generation Global Fused and Non-Fused Disconnects 0 A A Sizes Fused Switch Versions: - BS - DIN - CSA HRCII-C - CSA HRCI-MISC - UL Class J - UL Class CC - NFC Non-Fused
More informationWall-Mount Preferred-Cutout Disconnects Preferred Cutout, Disconnects, Type 12
763.422.2600 SPEC-00245 L763.422.2211 DISCONNECT WALL-MOUNT PREFERRED-CUTOUT DISCONNECTS PREFERRED CUTOUT, DISCONNECTS, TYPE 12 Wall-Mount Preferred-Cutout Disconnects Preferred Cutout, Disconnects, Type
More informationSelection Guide. Control Circuit and Load Protection
Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature
More informationBulletin 194R Next Generation Global Fused and Non-Fused Disconnects
Bulletin R IEC Fused and Non-Fused Disconnects, & A Overview Bulletin R Next Generation Global Fused and Non-Fused Disconnects A A Sizes Fused switch versions: - BS - DIN - CSA HRCII-C - CSA HRCI-MISC
More informationDisconnect Switches Type VBII (30-600A) with Flange Mounted Operating Handle
Features 30-600A, 600VAC and DC ratings UL Recognized (file # E121152 vol. 3) and CSA Certified under file number 15852 Visible blade quick make and break switching action Panel and Flange mounted assemblies
More information6.1. Low Voltage Busway. Low Voltage Busway Pow-R-Way and 100V. Features, Benefits and Functions
.1 Features, Benefits and Functions Pow-R-Way III Offers a Full Line of to Meet the Needs of the Global Marketplace Eaton Corporation has combined the requirements of NEMA, UL, CSA and IEC into one design
More informationPreferred Cutout, Disconnect Enclosure, Type 12
763.422.2600 Spec-00245 J763.422.2211 Wall-Mount Preferred-Cutout s Preferred Cutout, s, Type 12 Wall-Mount Preferred-Cutout s Preferred Cutout, s, Type 12 Preferred Cutout, Enclosure, Type 12 INDUSTRY
More informationSelector Push Button Cat. No. 800T-K2AAXX. a b c d e f g Right Left Right Left. d, e, f, g. Contact Blocks. No contacts on operator
NEMA Push Specifications 800T/H 30.5 mm Push s Selector Push Devices (Bul. 800T only) Selector Push Cat. No. 800T-K2AAXX 800T KD 2 G J D E a b c d e f g Right Left Right Left Blank C K KA KB KC KD KE a
More information1. Division 26 Section "Elevator Shunt-Trip Fused Disconnect Switches".
SECTION 26 28 16 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 01 Specification Sections,
More informationSIRCO PV UL98B Load break switches for photovoltaic applications from 100 to 2000 A, up to 1500 VDC
Load break switches sircopv_058_a cat SIRCO PV UL98 new sircopv_059_a cat The solution for > Combiner box > Recombiner box > Inverter Function SIRCO PV UL98 non fusible disconnect switches are heavy duty
More information150 B180 N B D A 8L. Enclosure Type. Input Line Voltage Open Type V AC, 3-phase, 50 and 60 Hz V AC, 3-phase, 50 and 60 Hz
Catalog Number Explanation Open Controllers a Bulletin Number Solid-State Controller B H H B B B B B B B B B B B B B Solid-State Controller and Isolation Contactor (enclosed only) b Controller Ratings
More informationPowerPact Circuit Breakers for Control Panel Disconnects Class 0611
Data Bulletin 0611DB0402 R04/16 05/2016 Replaces 0611DB0401 R11/11 PowerPact Circuit Breakers for Control Panel Disconnects Class 0611 Retain for future use. Introduction Certifications The electrical
More informationFUSIBLE DISCONNECT SWITCHES (UL98) GM SERIES
FUSIBLE DISCNECT SWITCHES (UL98) GM SERIES Three-pole disconnect switches with fuse holder (UL98) GMF...030 C12 GMFJ 100 C03 GMFJ 400 C03 GMFJ 800 C03 Add-on blocks GMX10 10 GMX3... GMX8 00 GMX8 01 GMX5...
More informationControl Power V AC, 50/60 Hz 150-C30NBD 150-C30FHD
Bulletin Product Selection Open Type and Non-Combination Enclosed (IP, NEMA /) Controllers For use with Line-Connected Motors Rated Voltage [V AC] / Motor Current [A]...... Max. kw, Hz Max. Hp, Hz Control
More informationSpec 5 Conduit Bodies, Covers and Gaskets For Rigid Conduit and IMC
NEC/CEC Suitable for use in the following Applications To provide access to conductors for pulling, splicing, maintenance and future changes/ upgrades. Allows connection of straight conduit runs, branch
More informationBulletin 1497A Machine Tool Transformers
Bulletin A Overview/Catalog Number Explanation Bulletin A Bulletin A are designed to reduce supply voltages to control circuits. The complete line of transformers is available with optional factory-installed
More informationStandard Product Low Profile Type 12 One-Door Disconnect Enclosures
763.422.2600 Spec-00005 M763.422.2211 Wall-Mount Preferred-Cutout s Low-Profile Type 12 s and Accessories Wall-Mount Preferred-Cutout s Low-Profile Type 12 s and Accessories Low-Profile, One- to Five-Door
More informationTransfer switch OT III open or delayed transition, non-automatic
Specification sheet Transfer switch OT III open or delayed transition, non-automatic 40 1000 amp Description The Cummins OTIII non-automatic transfer switch offers flexibility when remote controlled or
More informationAF40... AF96 3-pole contactors Technical data
Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional
More informationSmall Limit Switch D4V
Small Limit Switch DV Compact Vertical Models Sized for Asian Standards Compact new design approximately / the size of OMRON vertical Limit Switches. Structure enables the terminal section to be fully
More informationInterchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI
. Technical Data and Specifications Ratings Frames EG, JG and LG EG JG LG Maximum rated current (amperes) 15, 160 1 50 400, 630 Breaker type 3 B B E S S H H C E S H C U X E S H C U X of poles 1, 3, 4,
More informationXP Series Pre-Wired Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof System
NEC/ Applications Protection and control of electrical apparatus and circuits in hazardous environments, either indoor or outdoor. Designed for Class I, Division 2 areas where flammable gases or vapors
More informationBulletin 140G Accessories
Catalogs > Industrial Controls Catalog > Motor Control, IEC > Molded Case Circuit Breakers > Bulletin 140G Accessories Bulletin 140G Accessories Accessories Internal Electrical Accessories Auxiliary/Alarm
More informationDesign Standard. Purpose: Design Standard:
Design Standard Purpose: This design standard has the purpose of creating a consistent application of motor-control centers throughout the East Side Union High School District, therefore achieving a standard
More informationIEC Load Switches Bulletin 194E 25 Amps to 100 Amps
Description load switches are designed for use as local motor isolation and IEC disconnect switch applications outside North America. Available with 3- and 6-pole versions with add-on additional poles,
More informationManual Motor Starters. Meta-MEC
Manual Motor Starters Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 2 45 mm 70 mm 63AF 100AF 3 3 Manual LS Meta-MEC Motor Starters
More informationUL Class J and CSA HRCI-J Fuses ➋. obsolete. CSA HRCII-C Fuses. Maximum Horsepower ➊
Series U/CSA Fused Amp Rating 1 Ø (60Hz) Maximum Horsepower ➊ Three Phase (60Hz) DC Switch (typical) (A) 120V 240V 200V 240V 460V 600V 125V 250V Catalog Number Price U Class J and CSA HRCI-J Fuses ➋ 30
More informationPLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION
Explosionproof, Dust-Ignitionproof With Disconnect Switch or Circuit Breaker. Weatherproof Spring Cover. 600 Vac Max. 250 Vdc Max. Applications Locations where receptacles are used with stationary or portable
More informationTransfer switch OTEC and OTECSE open transition
Specification sheet OTEC and OTECSE open transition 125-600 Amp Description OTEC transfer es are designed for operation and ing of electrical loads between primary power and standby generator sets. They
More informationNEMA 4 and 12 Ultimate Single-Door Wall Mount Flanged Disconnect N412_CD Series
NEMA 4 and 12 Ultimate Single-Door Wall Mount Flanged Disconnect N412_CD Series Applications N412_CD Series Designed to house the following: AutomationDirect.com NEMA 1/12 Flexible shaft handle for Molded
More informationBulletin 1497A Machine Tool Transformers
Bulletin A Overview/Catalog Number Explanation Bulletin A Bulletin A are designed to reduce supply voltages to control circuits. The complete line of transformers is available with optional factory-installed
More informationOPERATOR ADAPTER A21ABA
OPERATOR ADAPTER A21ABA Installation Instructions for Allen Bradley Bulletin 1494F Disconnect Switches And Bulletin 1494D Circuit Breaker Operating Mechanisms (For parts list, see page 2) For floor mounted
More informationModel Number Structure
Small Sealed Switch D4E-@N Slim and Compact Switch with Better Seal and Ensuring Longer Service Life than D4E Flat springs with an improved lever ratio of the built-in switch ensure smooth snap action
More informationSquare D General Purpose Relays
Square D General Purpose Relays Class 0R plug-in relays 0RS (SPDT) 0RS (DPDT) 0RS3 (3PDT) 0RS (PDT) Catalog 0 Contents Class 0R plug-in relays bbspecifications....................................................
More informationNEMA 4 Single-Door Wall Mount Right-Flanged Disconnect SN4 Series
NEMA 4 Single-Door Wall Mount Right-Flanged Disconnect SN4 Series Applications SN4 Series Designed to house the following: Allen-Bradley Bulletin 1494V disconnect switches with flange-mounted variable
More informationAF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts
AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up
More informationPlexPower Factory Sealed Panelboard 15 to 150 Amps. Stainless Steel Enclosures
Applications The PlexPower panelboard provides indoor and outdoor protection and control of electrical circuits in hazardous environments such as: Petroleum plants Chemical plants Refineries Wastewater
More informationD2LC Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments
D2LC Series Circuit Breaker Panelboards for Harsh and Hazardous Environments IBUTI TR HA ON DIS KILLARK Z LO C Type 4X Gasket Stainless Steel Tri-Lead Cover Bolts Spare Sealed Wires Termination at Terminal
More information800 T FX 1 A1. Color Cap. No cap 1 Green 2 Black 3 Orange 4 Grey 5 White 6 Red 7 Blue 9 Yellow. Contact Block(s) Operator Position.
2-Position Push-Pull and Push-Pull/Twist Release Devices, Non-Illuminated Note: A jumbo or large legend plate is recommended, if space allows. 2-Position Push-Pull Cat. No. 800T-F6D4 2-Position Metal Push-Pull
More informationBUSWAY Low Voltage (Pow-R-Flex)
BUSWAY LOW VOLTAGE (POW-R-FLEX) PART 1 GENERAL 1.01 1.02 SCOPE The Contractor shall furnish and install the busway system including all necessary fittings, hangers and accessories as specified herein and
More informationSIRCOVER UL1008/98 Changeover switches standards UL and CSA 100 to 1200 A
Conformity to standards (1) Changeover switches svr-ul_14_b_1_cat > EC 6947-3 > UL98, Guide WHTY, file 1138 > UL18, Guide WPYV, file 31792 > CSA 22.2#4, Class 4651-2 (1) Product reference on request. svr_136_a_2_cat
More informationR6F30A1S R6F30A1S 1P 60A 600V Fuse BLK. Features. Long Description
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 Catalog Number Manufacturer Description Weight per unit Product Category Features Clip Type Fuse Current Rating Fuse Type
More informationType Contact form Enclosure ratings Model Standard SPST-NO (Class A) Flux protection G5LA-1A Sealed
PCB Relay G5LA A Cubic, Single-pole 1A Power Relay Economical cube relay with universal terminal footprint Conforms to VDE435, CQC UL recognized/ CSA certified. High switching power: 1A @ 5VAC Withstands
More information1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.
SECTION 262816 - ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Fusible switches. 2. Nonfusible switches. 3. Receptacle switches. 4. Shunt trip switches. 5.
More informationLoad Break Disconnect Switches FSLBS
Load Break Disconnect Switches FSLBS UL 508 Non-Fused Load Break Switches The FSLBS Load Break Switch is a newly designed industrial-grade switch capable of making or breaking loads up to 600V. It is suitable
More informationSelection Guide Motor Control Device Solutions
Selection Guide Motor Control Device Solutions Expect more and get it from c3controls. Our portfolio of Motor Control Devices consists of worldclass products designed and manufactured to meet your requirements
More informationNon-illuminated Push Buttons
Non-illuminated Push Buttons 3 Accessories for push buttons Lockout attachment Contact block kits Lens kits Wobblestick kit Push Button Cap Interchangeable, snap-in design Protective caps 9 colors: red,
More informationTransfer switch OTEC open or delayed transition
Transfer switch OTEC open or delayed transition 40-1000 Amp Description OTEC transfer switches are designed for operation and switching of electrical loads between primary power and standby generator sets.
More informationOTEC Transfer switch open transition
Specification sheet OTEC Transfer switch open transition 40 1200 amp Description OTEC transfer switches are designed for operation and switching of electrical loads between primary power and Standby generator
More informationHorsepower Ratings 240V AC 1 Phase, 2 Phase, 3 Phase, Ampere Catalog List Ship Wt.* Catalog List Ship Wt.* Indoor Type 1 Outdoor Type 3R
Safety Switches Heavy Duty 240 Volt Indoor Type Outdoor Type 3R Horsepower Ratings 240V AC Phase, 2 Phase, 3 Phase, Ampere Catalog List Ship Wt.* Catalog List Ship Wt.* 2 Wire 4 Wire 3 Wire System Rating
More informationDisconnect Switches Product Guide
Disconnect Switches Product Guide Rotary Switches Non-fused Fused Enclosed Rotary Operating Mechanisms Accessories December 4 Disconnect Switches 1 Manual Motor Disconnect Switches Contents Description
More informationNon-fusable disconnect switches standards UL and CSA from 16 to 100 A
Non-fusible disconnect switches sircm_132_a sircm_133_a The solution for > Industrial control systems Rotary switch SIRCO M 3 x 80 A Toggle switch SIRCO M 3 x 80 A + 2 auxiliary contacts Competitive advantages
More informationAF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101404D0201 24/03/11-30-10-.. / Z-30-10-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220
More informationSECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS
SECTION 26 28 16 ENCLOSED SWITCHES AND PART 1 - GENERAL 1.1 SUMMARY A. Section includes the following individually mounted, enclosed switches and circuit breakers rated 600V AC and less: 1. Fusible switches.
More informationApproved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1
Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC
More informationLighting and Power Distribution Panelboards
EXPLOSIONPROOf Lighting and Power Distribution Panelboards The design offers sufficient gutter space on sides to allow through wiring and easy lug connection. All enclosures are furnished with hinges,
More informationSPEEDFAX TM 2011 Disconnect Switches Contents
SPEEDFAX TM 2011 Disconnect es Contents Compact Non-Fusible es Rotary and Toggle Selection 5-2 5-4 Dimensions and Wire Ranges 5-5 Type VBII (30-600A) Features and Ordering Information 5-6 and Handle Selection
More informationD2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant
Applications Protection and control of electrical equipment and circuits such as lighting and heat tracing in hazardous locations or in damp, wet or corrosive conditions. D2P Series designed for use in
More informationsirco-ul_004_b_cat 100A to 2000A - 600VDC and 1000VDC UL98B Listed
site_317_a sirco-ul_22_b_cat sirco-ul_4_b_cat 1A to 2A - 6VDC and 1VDC UL98B Listed  Function non fusible disconnects are heavy duty switches that break and make 6VDC or 1VDC photovoltaic circuits on
More informationSeries C, F-frame molded case circuit breaker, 15A, Two-pole, Thermal Magnetic Trip, FD Breaker
FD2015 2 Pole 15A FD Eaton Corp Catalog Number Manufacturer Description Weight per unit Product Category Features amperage rating 15 Frame Size F-frame interrupt rating 35 kaic at 480V Poles 2 Trip Type
More informationHp V AC Current Rating [A] 230V AC 60 Hz
Product Selection/Options Open Type Controllers Up to V AC kw Hp V AC Current Rating [A] V AC Hz V AC Hz V AC Hz V AC Hz V AC Hz / Hz Control V AC/DC Control.. -BNBD -BNBR. -BNBD -BNBR -BNBD -BNBR -BNBD
More informationSafety Limit Switch
Safety Limit Switch D4B-@N CSM_D4B-_N_DS_E_5_1 Snap-action contact with certified direct operation certification. Maintenance, seal, and resistance to shock increased and direct mechanism added. Three-conduit
More informationD4B- N. Safety Interlock Switches. Safety Limit Switch. Specifications. Standards and EC Directives. Certified Standard Ratings D4BN
Safety Interlock Switches D4B- N D4BN Safety Limit Switch Snap-action contact with certified direct operation. mechanism (NC contacts only) added to enable contacts when faults occur, such as fused contacts.
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker
Magnetic and Hydraulic-Magnetic Circuit Breaker 835-... Description Single or multipole hydraulic-magnetic circuit breakers with trip-free - mechanism and toggle actuation. A choice of switching characteristics
More informationand legacy Motor Control Center Aftermarket Renewal Parts Catalog
tiastar TM and legacy Motor Control Center Aftermarket Renewal Parts Catalog Game Changing Innovation www.usa.siemens.com/mcc Answers for industry. Table of Contents Ordering Processes 1-2 Section Parts
More informationApplication Description
-14 Type, Intelligent Technologies (IT.) Soft Starters February 2007 Contents Description Page Type, Intelligent Technologies (IT.) Soft Starters Product Description....... -14 Application Description....
More informationPlexPower Fused Factory Sealed Panelboard with Bus Bar Up to 30 Amps. Stainless Steel Enclosures
Applications The PlexPower panelboard provides indoor and outdoor protection and control of electrical circuits in hazardous environments such as: Petroleum plants Chemical plants Refineries Wastewater
More informationCapacitors. Individual & fixed bank. Individual & fixed capacitor banks. Low Voltage Network Quality
Individual & fixed capacitor banks Low Voltage L O W V O L T A G E N E T W O R K Q U A L I T Y Individual & fixed bank Capacitors Description High reliability Well proven features of ABB dry type power
More informationF LANGE MOUNT DISCONNECT
F LNGE MOUNT DISCONNECT E Wallmount FMD s... FMD 1-2 NEM 4 Wallmount Boxes... FMD 3-4 NEM 12 Wallmount Boxes... FMD 5-6 TS8 Freestanding FMD s... FMD 7-8 PS Freestanding FMD s... FMD 9-10 Freestanding
More information