Applications. Housings: copperfree (4/10 of 1%) aluminum Shaft, bushings and exposed hardware: stainless steel Standard Finishes
|
|
- Lee Rogers
- 6 years ago
- Views:
Transcription
1 AE Threaded Combination and Non-Combination Full Motor Starters Units Provide Disconnecting Means and Undervoltage, Circuit and Motor Running Protection. Class I, Division and, Groups C, D Class II, Division and, Groups E, F, G Applications AE series threaded type combination and non-combination motor starters are used in areas where hazardous materials are handled or stored. These units provide disconnecting means, undervoltage protection, circuit protection and motor running protection. Full voltage across the line starting and stopping of squirrel cage induction motors. Remote starting and stopping motor as needed. Features Cast on slotted mounting feet. Ground lug package and installation instructions for termination of ground wires. Reset operator with stainless steel shaft. Breaker handles can be locked in the ON or OFF position (combination starters only). Drilled and tapped outlets. Standard outlets are determined by motor starter size. Outlets for remote control wiring. Plugged / outlets top and bottom for breather and drain. Three plugged / NPSM outlets drilled and tapped for needed lights or switches. Ample space is provided for installation and wiring of additional accessories. Painted removable pan. Enclosures are designed to accept GE, Square D and Cutler-Hammer motor starters. For other brands contact your local representative. Cutler-Hammer furnished standard unless otherwise specified. Motor circuit protectors are available on combination starters. Enclosures furnished with or without components. Readily accessible circuit breaker mounted outside the center housing. Rated for NEMA X (gray epoxy-coated inside and outside). Acme screw type square threads designed to prevent seizing. Bell threads are located inside the housing protects against damage or contaminants. Standard Materials Housings: copperfree (/ of %) aluminum Shaft, bushings and exposed hardware: stainless steel Standard Finishes Housings: epoxy - coated inside and outside Options See modifications page. NEC Certifications and Compliances UL Standards: UL 8, UL 698, UL UL Classified: E877 Exterior Interior GE is a registered trademark of General Electric Company. Square D is a registered trademark of Schneider Electric. Cutler-Hammer is a registered trademark of Eaton Corporation. Visit our website at or contact us at (8) 6-6. April 6
2 AE Threaded Combination and Non-Combination Full Motor Starters Units Provide Disconnecting Means and Undervoltage, Circuit and Motor Running Protection. Controls Class I, Division and, Groups C, D Class II, Division and, Groups E, F, G NEC/CEC CLASS/ZONE RATED HAZARDOUS LOCATION MOTOR STARTERS Catalog Numbering Guide AE T M 8 NEC Certified Explosionproof Motor Starter Enclosure: AE - Combination Full AES - Full NEMA Size: Breaker Type: M - Magnetic Only T - Thermal Magnetic Line : Breaker Trip: - Amps 7-7 Amps - Amps - Amps - Amps - Amps - Amps - Amps - Amps - Amps - Amps 7-7 Amps - Amps - Amps - Amps - Amps Suffix for Other Options/Features: See Modifications Enclosure Type: T - Threaded Horsepower: Visit our website at or contact us at (8) 6-6. April
3 AE Threaded Combination/Non-Combination Full Motor Starter Modifications Threaded Enclosure. -Phase, 6 Hertz, Nonreversing. Class I, Division and, Groups C, D Class II, Division and, Groups E, F, G Suffix Factory Installed Catalog Number Field Installed Description Operators Start/Stop dual push button SX AEPDGRE Stop push button SX AEPRC Start push button SX AEPGA Stop, lighted PB, red Vac LPX AEPTRE Start, lighted PB, green Vac LPX AEPTGE position selector switch specify legend AX AESSMN position selector switch specify legend AX AESSML Red pilot light, Vac L AEPLR Green pilot light, Vac L AEPLG Red pilot light, Vac L AEPLR Green pilot light, Vac L AEPLG Red pilot light, 8 Vac L AEPLR Green pilot light, 8 Vac L AEPLG NEMA X Breather/Drain Fittings Drain fitting DN DRNBX Breather fitting (Drilled and tapped installation included.) BR BRTBX Control Power Options Fused CPT, Vac T AFCPT Fused CPT, Vac T AFCPT Fused CPT, Vac T AFCPT Fused CPT, Vac T AFCPT Fused CPT, Vac w/interposing Relay T AFCPTR Fused CPT, Vac T6 AFCPT Fused CPT, Vac T7 AFCPT Fused CPT, Vac T8 AFCPT Fused CPT, 7 Vac T9 AFCPT7 Separate control fused circuit S-V N/A Specify starter coil voltage S-V N/A S-8V N/A Description Nameplates Engraved nameplate black letters on white surface,.8 x.6 mm ( x ),.8 mm (. ) letters, lines max. specify legend Suffix Factory Installed NP Catalog Number Field Installed n/a Overload Heater Provide FLA at the time of order. W enclosure space heaters Vac O-V AFA7X Vac O-V AFA7X 8 Vac O-8V AFA7X Control Terminal Blocks (Above points contact your local representative) Amp, 6 Vac 8 point 8K N/A NEMA B w/wire markers point K N/A Interrupt Ratings k AIC standard. Contact your local representative for higher interrupt capacities. Cutler-Hammer Starter Auxiliary Contacts Size - NO/NC XC AJ- NO/NC XC AJ- ( ea.) NO/NC XC A6D9G8 Size NO/NC XC A6D9G8 ( ea.) Square D Starter Auxiliary Contacts Size - NO/NC XS A999SX8 NO/NC XS A999SX8 ( ea.) NOTE: CPT includes primary and secondary fuses. Add L to part no. for Size starters. Size and Vac Max. Size and Vac Max. Contact your local representative for other voltages. 8 Aux. Contacts Max. includes one seal-in and seven added. Aux. Contacts Max. includes one seal-in and three added. Size - includes one seal-in and four added. Size - includes one seal-in and three added. Cutler-Hammer is a registered trademark of Eaton Corporation. Square D is a registered trademark of Schneider Electric. Visit our website at or contact us at (8) 6-6. April 6
4 AE Threaded Combination Full Motor Starters With Thermal Magnetic Breakers Threaded Enclosure. -Phase, 6 Hertz, Nonreversing. Controls Class I, Division and, Groups C, D Class II, Division and, Groups E, F, G NEC/CEC CLASS/ZONE RATED HAZARDOUS LOCATION MOTOR STARTERS Line 8 6 Conduit Sizes Loc. A, B, C and D Horsepower NEMA Size Breaker Amps Catalog Numbers Weight kg (lb) Standard Mounting Hardware Set Catalog Number AETT- AETT- (7) -/ -/ AETT- 7-/ AETT-7 (7) -/ -/ AETT- AETT- () -/ -/ AETT- AETT- 7 () -/ 7 AETT-7 AETT- 9 () -/ -/ 6 AETT-6 7 AETT-7 () AMH AETT- AETT-8 AETT-8 (7) -/ -/ 7-/ AETT-87 (7) -/ -/ AETT-8 AETT-8 7 AETT-87 () -/ -/ AETT-8 7 () -/ 6 AETT-86 7 AETT-87 9 () -/ -/ AETT-8 AMH AETT-8 AETT-8 () AMH AETT-8 AETT-6 (7) -/ -/ 7-/ AETT-67 AETT-6 (7) -/ -/ AETT-6 () -/ -/ AETT-6 7 AETT-67 AETT-6 7 () -/ 7 AETT-67 AETT-6 9 () -/ -/ AETT-6 () AETT-6 6 () AMH To complete the catalog number please add the appropriate suffix for other options/features. Suffixes, see AE Threaded Combination and Non-Combination Full Motor Starter Modifications. 6 Visit our website at or contact us at (8) 6-6. April
5 AE Threaded Combination Full Motor Starters With Magnetic Breakers Threaded Enclosure. -Phase, 6 Hertz, Nonreversing. Class I, Division and, Groups C, D Class II, Division and, Groups E, F, G Line 8 6 Conduit Sizes Loc. A, B, C and D Horsepower NEMA Size Breaker Amps Catalog Numbers Weight kg (lb) Standard Mounting Hardware Set Catalog Number 7 AETM-7 AETM- (7) -/ -/ 7 AETM-7 (7) -/ -/ AETM- () -/ -/ AETM- 7 () -/ AETM- 7 () -/ -/ AETM- () AMH AETM-8 7 AETM-87 (7) -/ -/ AETM-8 7 AETM-87 (7) -/ -/ AETM-8 AETM-8 AETM-8 () -/ -/ AETM-8 7 () AETM-8 -/ AETM-8 7 () -/ -/ AETM-8 () AMH AETM-6 7 AETM-67 (7) -/ -/ AETM-6 7 AETM-67 AETM-6 (7) -/ -/ AETM-6 () -/ -/ AETM-6 AETM-6 AETM-6 7 () -/ 6 AETM-66 AETM-6 7 () -/ -/ AETM-6 () AETM-6 AMH To complete the catalog number please add the appropriate suffix for other options/features. Suffixes, see AE Threaded Combination and Non-Combination Full Motor Starter Modifications. Visit our website at or contact us at (8) 6-6. April 6
6 AE Threaded Full Motor Starters Threaded Enclosure. -Phase, 6 Hertz, Nonreversing. Controls Class I, Division and, Groups C, D Class II, Division and, Groups E, F, G NEC/CEC CLASS/ZONE RATED HAZARDOUS LOCATION MOTOR STARTERS Line 8 6 Aluminum Conduit Sizes Loc. A, B, C and D Horsepower NEMA Size Catalog Numbers Weight kg (lb) Standard Mounting Hardware Set Catalog Number AEST- (6) -/ -/ 7-/ AEST-7 (6) -/ -/ AEST- 8 () -/ -/ AEST- () -/ AEST- () -/ -/ AEST- 6 () AMH AEST-8 (6) -/ -/ AEST-8 (6) -/ -/ AEST-8 8 () -/ -/ AEST-8 () -/ AEST-8 () -/ -/ AEST-8 6 () AMH AEST-6 (6) -/ -/ AEST-6 (6) -/ -/ AEST-6 8 () -/ -/ AEST-6 () -/ AEST-6 () -/ -/ AEST-6 6 () AMH To complete the catalog number please add the appropriate suffix for other options/features. Suffixes, see AE Threaded Combination and Non-Combination Full Motor Starter Modifications. 66 Visit our website at or contact us at (8) 6-6. April
7 AE Threaded Combination/Non-Combination Full Motor Starter Threaded Enclosure. -Phase, 6 Hertz, Nonreversing. Dimensions in Millimeters Dimensions are approximate, not for construction Dimensions AET and AEST AET and AEST AET and AEST AET and AEST AET and AEST AET and AEST E 7. (.6) 7. (.6). (.88) 9.8 (.8) 9.8 (.8) 98.6 (9.) F 66. (6.) 66. (6.) 77.7 (.). (9.). (9.) 8.9 (.) G 87. (.) 87. (.) 88.9 (9.). (.). (.) 7.8 (7.7) H. (8.). (8.). (8.). (8.). (8.) J.6 (.7).6 (.7).6 (.7).6 (.7).6 (.7) K 6.6 (.8) 6.6 (.8). (.) 9. (7.) 9. (7.) 8.7 (.) L 9. (.7) 9. (.7) 9. (.7) 9. (.7) 9. (.7) 6. (.7) M 6.9 (.6) 6.9 (.6) 6.9 (.6). (.) N 9. (7.) 9. (7.) 9. (7.) 96.8 (7.7) 66.7 (.) 6. (6.) P 79. (.) 79. (.) 7. (8.) 8. (.) 8. (.). (.6) Q 8.6 (7.) 8.6 (7.) 8. (9.8) 9. (8.6) 9. (8.6) 89. (.8) R. (.6). (.6) 69.8 (.7) 76. (.) 76. (.) 7. (.) S.8 (.) T 6. (6.) Approximate Weight in Kilograms (Pounds) For Enclosure Only AET AET AET AET AET AET 7. (6) 7. (6). () 9. () 9. () 9. () AEST AEST AEST AEST AEST AEST 7. (6) 7. (6).7 (9). (). () 87.7 (9) Visit our website at or contact us at (8) 6-6. April 67
O-3. Compliances UL Classified UL 508, 698, 1203 NEMA 4, 4X, 7CD, 9EFG For CSA approvals, please consult factory.
Combination and Non-Combination Full Voltage Motor Starters: Units Provide Disconnecting Means and Undervoltage, Circuit and Motor Running Protection. -3 Applications AE series threaded type combination
More informationStandard Materials Bodies and covers: copper-free aluminum.
-26 AEB Series: Bolted Combination and Non-Combination Full Voltage Motor Starters: Units Provide Disconnecting Means and Undervoltage, Circuit and Motor Running Protection. Application Combination and
More informationNEC/CEC CLASS/ZONE RATED HAZARDOUS LOCATION CIRCUIT BREAKERS. Application
- and 3-Pole, Non-Interchangeable Trip. Bolted Enclosure Type. Class I, Division 1 and, Groups B, C, D Class II, Division 1 and, Groups E, F, G Distribution Equipment NEC/CEC CLASS/ZONE RATED HAZARDOUS
More informationDISTRIBUTION EQUIPMENT: NEC/CEC HAZARDOUS LOCATION SWITCHES. Application
- and 3-Pole, Non-Interchangeable Trip. Bolted Enclosure Type. Class I, Division 1 and, Groups B, C, D Class II, Division 1 and, Groups E, F, G Application Explosionproof circuit breaker enclosures are
More informationNEC DBR Receptacle: Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG
EBR/DBR 30, 60, 100 and 150 Amp Series Receptacles With Disconnect Switch or Circuit Breaker. Weatherproof Spring Cover. Explosionproof, Dust-Ignitionproof 600 Vac Max. 250 Vdc Max. NEC EBR Receptacle:
More informationEnclosures for hazardous areas EBMX clamped enclosures. Clamped EBMX. NEMA 7 classifi ed enclosures
Enclosures for hazardous areas clamped enclosures Clamped NEMA 7 classifi ed enclosures Clamped : NEMA 7 classified enclosures Safer. Faster. Easy access, lower risk and less downtime. Creative thinking
More informationCIRCUIT BREAKERS. Explosionproof Circuit Breaker Enclosures EXPLOSIONPROOF MOTOR CONTROL EXPLOSIONPRROOF MOTOR CONTROL BREAKERS ENCLOSURES
CIRCUIT BREAKERS Explosionproof Circuit Breaker Enclosures BREAKERS Circuit breakers are thermal magnetic type and are available in frame sizes ranging from 15 to 800 amperes Also available as non-automatic
More informationPLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION
Explosionproof, Dust-Ignitionproof With Disconnect Switch or Circuit Breaker. Weatherproof Spring Cover. 600 Vac Max. 250 Vdc Max. Applications Locations where receptacles are used with stationary or portable
More informationD2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant
Applications Protection and control of electrical equipment and circuits such as lighting and heat tracing in hazardous locations or in damp, wet or corrosive conditions. D2P Series designed for use in
More informationDBR Receptacle Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG
EBR/DBR 30, 60, 100 and 150 Amp Series Receptacles With Disconnect Switch or Circuit Breaker. Weatherproof Spring Cover. Explosionproof, Dust-Ignitionproof 600 Vac Max. 250 Vdc Max. EBR Receptacle Class
More informationPLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION
DBR 30, 60, 100 and 150 Amp Series Receptacles Explosionproof, Dust-Ignitionproof With Disconnect Switch or Circuit Breaker. Weatherproof Spring Cover. 600 Vac Max. 250 Vdc Max. Applications Locations
More informationEBMC Combination Line Starters and Enclosures
EBMC Combination Line 3, 3R, 4, 4X, 7BCD, 9EFG, 12 Applications: Spectrum EBM hinged cover motor control enclosures are used: For general motor control and circuit protection indoors and outdoors in damp,
More informationALPF Factory Sealed Lighting - APPF Power Distribution Panelboards Explosionproof, Dust-Ignitionproof, Watertight
ALPF Factory Sealed Lighting - APPF Power Distribution boards xplosionproof, Dust-Ignitionproof, Watertight NC: Class II, Division 1 and 2, Groups, F, G NA 4, 4X, 7BCD, 9FG Applications Distribution panelboards
More informationProduct Description. Junction Boxes...V1-V23 Meter and Instrument Enclosures...V24-V33
SECTION V INDEX Product Description Page Number Junction Boxes......................................V-V2 Meter and Instrument Enclosures.......................V24-V Control Centers.....................................V4-V9
More informationLighting and Power Distribution Panelboards
EXPLOSIONPROOf Lighting and Power Distribution Panelboards The design offers sufficient gutter space on sides to allow through wiring and easy lug connection. All enclosures are furnished with hinges,
More informationSECTION MOTOR CONTROL
SECTION 26 24 19 MOTOR CONTROL PART 1 - GENERAL 1.1 SECTION INCLUDES A. Manual motor starters B. Magnetic motor starters C. Combination magnetic motor starters D. Solid-state reduced voltage motor starters
More informationXP Series Pre-Wired Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof System
NEC/ Applications Protection and control of electrical apparatus and circuits in hazardous environments, either indoor or outdoor. Designed for Class I, Division 2 areas where flammable gases or vapors
More informationA. Products shall be designed, manufactured, tested, and installed in compliance with the following standards:
SECTION 26 29 13 ENCLOSED MOTOR CONTROLLERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical General
More informationEnclosures. See Section Typical Description
January 00 Sheet 1187 Motor Starters & Contactors Low Voltage Enclosures General Individual Enclosed, ac Full Voltage.7- Combination Starters Maximum 00 hp, Volts Application Size 1, NEMA 1, Enclosed Magnetic
More informationA. This Section includes ac, enclosed controllers rated 600 V and less, of the following types:
SECTION 262913 600 VOLT ENCLOSED CONTROLLERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 0 Specification
More informationReceptacle housing and cover optional malleable iron on EFS-M Series. Spring-loaded cover seats against neoprene gasket.
U-Line Factory Sealed 20 Amp Plugs and Receptacles Dead-Front Safety Construction. Choice of Aluminum or Thermoplastic Polyester Plug. Class I, Division 1 and 2 Groups B, C, D NEMA 3, 3R, 7BCD, 9FG Applications
More informationSECTION PANELBOARDS
SECTION 16470 PANELBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work under
More information3. Coils shall be of molded construction
.7-4 Motor Starters & Contactors Low Voltage Enclosures General Non-Combination Starters January 00 Sheet 8 0 7 8 9 4 Non-Combination Starters Maximum hp, Volts Typical Non-Combination Starter Application
More informationP-9. ALPN, APPN and AGPN Series: Explosionproof, Dust-Ignitionproof, Watertight Non-Factory Sealed.
ALN, AN and AGN Series: Non-Factory Sealed. -9 Applications Distribution panelboards are used to furnish protection and control of electrical equipment in hazardous locations. These compact units provide
More informationCONTROLS: NEC/CEC EXPLOSIONPROOF CONTROL STATIONS AND SWITCHES. Applications. Illustrated Features
Explosionproof, Dust-Ignitionproof Malleable Iron Body and Cover. Furnished with Internal Ground. Applications Designed to prevent arcing of enclosed switches in ignitable atmospheres during connect and
More informationNMC Combination Line Starters and Enclosures
NMC Combination Line Starters 600VAC Heavy uty atertight eatherproof Applications: NMC combination magnetic line starters are for use in across-the-line motor starting, motor disconnect, motor and line
More informationFM9 Aluminum Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC.
Applications Serve as pulling fittings. Make bends in conduit system. Provide openings for splicing. Connect and change direction of conduit runs. Allow connections for branch runs. Permit access to conductors
More informationMotor Starters Hazardous and Non-Hazardous
Motor Starters Hazardous and Non-Hazardous Description Page No. Application/Selection 342 Magnetic Line Starters & Enclosures Single speed, non-reversing EBMS Series 343-346 EPC Series 349-351 EBMS Series
More informationP-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant
P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant Applications Protection and control of electrical equipment and circuits
More informationApplications. Separate sealing chamber and switch construction. Used on 20 Amp 4-way and all 30 Amp models.
Contender Series Factory Sealed Front Operated Tumbler Switches Malleable Iron Body and Cover. Furnished with Internal Ground. NEMA 3, 7CD, 9EFG Applications Designed to prevent arcing of enclosed switches
More informationStandard Finishes Receptacles: epoxy powder coat Cord connector housings and caps: epoxy powder coat
U-Line Factory Sealed 15 and 20 Amp Plugs and Receptacles V Applications Locations where receptacles are used with stationary or portable electrically operated devices such as: Lighting systems Conveyors
More informationU-Line Contender Factory Sealed 20 Amp Plugs and Receptacles Explosionproof, Dust-Ignitionproof
U-Line Contender Factory Sealed 20 Amp Plugs and Receptacles Explosionproof, Dust-Ignitionproof Class I, Groups C, D Class I, Division 2, Group B Class I, Zone 1, Group IIB Class I, Zone 2, Group IIB +
More informationEFS Non-Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof Malleable Iron Body and Cover. Furnished with Internal Ground Screw.
Explosionproof, Dust-Ignitionproof Malleable Iron Body and Cover. Furnished with Internal Ground Screw. Applications Designed to prevent arcing of enclosed switches in ignitable atmospheres during connect
More informationOverload Relay Heater Tables
Overload Relay Tables of Elements for Overload Relays General Use only when motor full load current is not known. Motor amps will vary depending on the type and manufacturer of the motor. These average
More informationForm 85 Unilets Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum, IMC, and EMT Conduit.
For use with Rigid Steel, Rigid Aluminum, IMC, and EMT Conduit. NEC/CEC Suitable for use in the following Applications Serve as pulling fittings. Make bends in conduit system. Provide openings for splicing.
More informationEDS Factory Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof UNILETS for Use with Threaded Metal Conduit.
UNILETS for Use with Threaded Metal Conduit. Class I, Division 1 and 2, Groups B, C, D Applications Designed to prevent arcing of enclosed switches in ignitable atmospheres during connect and disconnect
More informationPoles 3 Starter Size NEMA 3 NON ALUMINUM LINE TERMINAL, LOAD TERMINAL
3804 South Street 75964-763, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 H100R3C 3P 100A 600V F-Frame MC Protector Eaton Corp Catalog Number H100R3C Manufacturer Eaton Corp Description Motor Circuit
More informationFM8 Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.
NEC/CEC Suitable for use in the following Applications Serve as pulling fittings. Make bends in conduit system. Provide openings for splicing. Connect and change direction of conduit runs. Allow connections
More informationDivision 1 Explosionproof Panelboards
Division 1 Explosionproof Panelboards Designed for use in Class 1, Division 1 Zone 1 areas such as petroleum refineries, chemical or petrochemical facilities, the X1Pb panelboards are used to control lighting
More informationThe Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller
The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller A pre-engineered solution with an integrated circuit breaker disconnect and an Altistart 22 soft start in a stand-alone enclosure Make the
More informationReceptacle housing and cover optional malleable iron on EFS-M Series. Spring-loaded cover seats against neoprene gasket.
U-Line Factory Sealed 20 Amp Plugs and Receptacles Dead-Front Safety Construction. Choice of Aluminum or Thermoplastic Polyester Plug. Class I, Division 1 and 2 Groups B, C, D NEMA 3, 3R, 7BCD, 9FG Applications
More informationIndustrial Control & Circuit Breakers
Industrial Control & Circuit Breakers Section C Innovative, intelligent NEC and IEC solutions safely and efficiently control power and protect circuits in explosive, wet, and corrosive environments worldwide.
More informationEDS / EFS Series Control Stations
EDS / EFS Series Control Stations Fully Assembled EFS and EDS Factory Sealed Devices Cl. I, Div. & 2, Groups B*, C, D Cl. II, Div., Groups E, F, G NEMA, 7B*CD, 9EFG Applications: Factory sealed enclosures
More informationEDS / EFS Series Control Stations
EDS / EFS Series Fully Assembled EFS and EDS Factory Sealed Devices Cl. I, Div. & 2, Groups B*, C, D Cl. II, Div., Groups E, F, G NEMA, 7B*CD, 9EFG Applications: Factory sealed enclosures are installed
More informationProtectors. 35mm DIN rail snap-on mounting. Wide range of accessories
Manual motor protectors Manual motor protectors Manual motor Protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certified
More informationSECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS
SECTION 26 28 16 ENCLOSED SWITCHES AND PART 1 - GENERAL 1.1 SUMMARY A. Section includes the following individually mounted, enclosed switches and circuit breakers rated 600V AC and less: 1. Fusible switches.
More informationHazardous Factory Sealed Control Devices
Hazardous Factory Sealed Control Devices Description Page No. Application/Selection 428, 429 Dimensions 40 Manual Motor Starting Switches & Enclosures EDS Series 440, 44 Pilot Lights EFS Series 45 Pilot
More informationCircuit Breakers Hazardous
s Hazardous 3C Description Page No. Application/Selection 364 Auxiliary s & s EFD, EFDC Series 382 Thermal Magnetic s & s General Information and Dimensions EPC Series 370, 371 FLB Series 375 EBMB Series
More informationT38 1" T Form 7 Malleable Iron Conduit Body. Material, Color, and Finish Color Gray 0 Zinc Electroplate/Chromate/Epoxy Powder Coat
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 T38 1" T Form 7 Malleable Iron Conduit Body Appleton/Oz Gedney Catalog Number Manufacturer Description Weight per unit
More informationPlexPower Factory Sealed Panelboard 15 to 150 Amps. Stainless Steel Enclosures
Applications The PlexPower panelboard provides indoor and outdoor protection and control of electrical circuits in hazardous environments such as: Petroleum plants Chemical plants Refineries Wastewater
More informationPlexPower Fused Factory Sealed Panelboard with Bus Bar Up to 30 Amps. Stainless Steel Enclosures
Applications The PlexPower panelboard provides indoor and outdoor protection and control of electrical circuits in hazardous environments such as: Petroleum plants Chemical plants Refineries Wastewater
More informationSection SWITCHBOARDS. Introduction. Part 1 - General. Related Work
Section 16435 - SWITCHBOARDS Introduction Part 1 - General Related Work Section 16070 Seismic Anchorage and Restraint Section 16075 Electrical Identification Section 16080 Power Distribution Acceptance
More informationEDS / EFS Series Control Stations
EDS / EFS Series Control Stations Fully Assembled EFS and EDS Factory Sealed Devices Cl. I, Div. &, Groups B*, C, D Cl. II, Div., Groups E, F, G Cl. II, Div., Groups F, G NEMA, 7B*CD, 9EFG Applications:
More informationExplosionproof enclosures XPCJ series Cast aluminum steel control/junction box
1 TECHNICAL DATA SHEET Explosionproof enclosures XPCJ series Cast aluminum steel control/junction box XPCJ series series of explosionproof aluminum enclosures are typically used in the packaging of electrical/electronic
More informationECN A A A - B - C - D - E - F - A - B - C - D - E - F - NEMA Size 5 - Size Size Size Size Size 9
February 999 NEA Freedom Contactors and ers Catalog Number Selection - ECN A A F - Design N = Nema odification Codes (See Pages -6 to -) Class Page 0 - Contactors -4 0 - Reversing Contactors -8 05 - FVNR
More informationFile E47705 Vol. 7 Sec. 9 Page 1 Issued: and Report Revised:
File E47705 Vol. 7 Sec. 9 Page 1 Issued: 1997-08-29 and Report Revised: 2005-06-30 DESCRIPTION PRODUCT COVERED: USL, CNL - Type Nos. 3RV1021, 3RV1121, 3RV1321 or 3RV1421, followed by combination of 0,
More informationManual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X
Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL ed and
More informationBussmann series Quik-Spec Power Module Switch elevator disconnect
Supersedes January 2016 Agency information UL 98 enclosed and dead-front switch - Guide WIAX, WIAX7 (Canada), File E182262 culus, NEMA 1, UL 50, Listed enclosure cul per Canadian Standards C22.2, No. 0-M91-CAN/
More information3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,
Low-Voltage Controls and Distribution > Industrial Controls > Protection Equipment > Circuit Breakers/Motor Starter Protectors > Motor Starter Protectors SIRIUS RV up to 00 A RV0-0DA5 CIRCUIT-BREAKER,
More informationEIC combination motor starters
pplications: Harsh and hazardous motor control environments, including refineries, chemical and petrochemical plants, corrosive process facilities, food and beverage, marine and mining cross-the-line starting
More informationA302DN.40/.63A Thermal Current Motor Starter
4 South Street 7964-76, TX Nacogdoches Phone: 96-69-794 Fax: 96-60-468 A0DN.40/.6A Thermal Current Motor Starter Eaton Corp A0DN Manufacturer Eaton Corp Description Manual Motor Starter, Motor Protector;
More informationEDS Factory Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof UNILETS for Use with Threaded Metal Conduit.
EDS Factory Sealed Tumbler Switches UNILETS for Use with Threaded Metal Conduit. Class I, Division 1 and 2, Groups B, C, D NEMA 7 B CD, 9EFG Applications Designed to prevent arcing of enclosed switches
More informationDivision 2 Contender Series Factory Sealed Control Stations
NEMA 3, 3R, 4, 4X, 12 IP66 Applications For use in washdown areas and other damp, wet and highly corrosive areas. Push buttons and selector switches are used in conjunction with contactors or magnetic
More information3.1. NEMA Manual Starters. Contents Description Types B230, B330, Switches... MS Series, Single-Phase Starters...
Product Description The B100 Manual Motor Starters can be used in single-phase applications rated hp at 240 Vac or 2 hp at 20 Vdc. The starter can also be rated for three-phase applications up to 10 hp
More informationMECHANICAL AND ELECTRICAL COORDINATION SECTION MECHANICAL AND ELECTRICAL COORDINATION PART 1 - GENERAL
13686.00 MECHANICAL AND ELECTRICAL COORDINATION 230002-1 SECTION 230002 MECHANICAL AND ELECTRICAL COORDINATION 1.1 WORK INCLUDED PART 1 - GENERAL A. Work Included in This Section: Materials, equipment,
More informationX1PB: Explosionproof Panelboards
X1PB: Explosionproof FEATURES Spring-loaded through the door circuit breaker handles for 1P, 2P, and 3P breakers Padlock provision for breaker handles Copper bus bars Aluminum hinge with stainless steel
More informationMAGNETIC MOTOR STARTERS
H A Z m MAGNETIC MOTOR Class I, Div. 1 & 2, Groups B, C, D Class l, Zones 1 & 2, Groups llb, lla Class II, Div. 1 & 2, Groups E, F, G Class III, Div. 1 & 2 ENCL. Type, 4 & 4X - File E8969 Applications
More informationSECTION MOTOR REQUIREMENTS for HVAC
PART 1 GENERAL 1.1 SECTION INCLUDES A. Single-phase electric motors B. Three-phase electric motors 1.2 REFERENCES SECTION 23 05 13 MOTOR REQUIREMENTS for HVAC A. ABMA 9 - Load Ratings and Fatigue Life
More informationPRODUCT DRAWING WIRING DIAGRAM FIELD CONNECTIONS MILLENNIUM MODEL YT CHILLERS (STYLE J) WITH ELECTRO-MECHANICAL STARTER JOB DATA:
Supersedes: 160.55-PW4 (1199) FORM 160.55-PW4 (600) PRODUCT DRAWING YORK INTERNATIONAL CORPORATION P.O. Box 1592, YORK, PA 17405 CONTRACTOR ORDER NO. YORK CONTRACT NO. YORK ORDER NO. WIRING DIAGRAM FIELD
More informationSECTION COMMON MOTOR REQUIREMENTS FOR HVAC EQUIPMENT
SECTION 230513 - COMMON MOTOR REQUIREMENTS FOR HVAC EQUIPMENT PART 1 GENERAL 1.1 SECTION INCLUDES A. Single phase electric motors. B. Three phase electric motors. 1.2 REFERENCE STANDARDS A. ABMA STD 9
More informationELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY[R] IRON ALLOY (US), COPPER FREE ALUMINUM (CANADA)
804 South Street 75964-726, TX Nacogdoches Phone: 96-569-794 Fax: 96-560-4685 EDS25 -Gang Start/Stop Station Cooper Crouse-Hinds Catalog Number Manufacturer Weight per unit Product Category Features Assembly/Kit
More informationFM9 Aluminum Unilet Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC.
FM9 Aluminum Unilet Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC. : Conduit Bodies Applications Serve as pulling fittings. Make bends in conduit system. Provide
More informationHID/FLOODLIGHT: NEC/CEC EXPLOSIONPROOF. Applications. Options
Applications UL Listed for Outside Type (Salt Water). Ideal in Class I, Division 1 and 2 installations in refineries, in pipeline transportation facilities, at drilling rigs and in production facilities
More informationTypes of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are:
Introduction Motor starters are one of the major inventions for motor control applications. As the name suggests, a starter is an electrical device which controls the electrical power for starting a motor.
More informationFM7 Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.
NEC/CEC Suitable for use in the following Applications Serve as pulling fittings. Make bends in conduit system. Provide openings for splicing. Connect and change direction of conduit runs. Allow connections
More informationEFS Non-Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof Malleable Iron Body and Cover. Furnished with Internal Ground Screw.
EFS Non-Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof Malleable Iron Body and Cover. Furnished with Internal Ground Screw. Controls CONTROLS: HAZARDOUS LOCATION CONTROL STATIONS AND SWITCHES
More information1. Division 26 Section "Elevator Shunt-Trip Fused Disconnect Switches".
SECTION 26 28 16 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 01 Specification Sections,
More informationPREFACE ********************************************************** IT IS NOT INTENDED THAT THESE STANDARDS BE COPIED AND USED AS A SPECIFICATION!
PREFACE This publication has been prepared as a guide for Architectural and Engineering (A&E) firms in the preparation of documents for the design and construction of new structures and the remodeling
More informationWell-Guard Control. Pumping Plant Panels. Catalog 8940CT9701R11/ Class 8940
Well-Guard Control Pumping Plant Panels Catalog 8940CT9701R11/15 2016 Class 8940 IRRIGATION OIL PRODUCTION CONTENTS Selection.............................................. Page 3 Factory Modifications.....................................
More informationSpring-loaded cover seats against neoprene gasket.
U-Line Factory Sealed 20 Amp Plugs and Receptacles Dead-Front Safety Construction. Choice of Aluminum or Thermoplastic Polyester Plug. Class I, Division 1 and 2 Groups B, C, D NEMA 3, 3R, 7BCD, 9FG Plugs
More informationPlugs and Receptacles: Hazardous Location
U-Line Factory Sealed 15 and 20 Amp Plugs and Receptacles V Plugs and Receptacles Plugs and Receptacles: Hazardous Location Applications Locations where receptacles are used with stationary or portable
More informationPlug and Play Kit Installation and Wiring (Non-Combo and Combo)
General Information This publication is to be used for Eaton Plug and Play enclosures designed starters that accept the M22 series 22mm cover control devices. To install the cover control kit (Follow the
More informationIM K IM K. Instructions for Cutler-Hammer Jockey Pump Controllers
IM05805004K IM05805004K Instructions for Cutler-Hammer Jockey Pump Controllers IM05805004K Page i TABLE OF CONTENTS 1. INSTALLATION AND MOUNTING OF THE CONTROLLER... 1 2. SYSTEM PRESSURE CONNECTIONS...
More informationSECTION MOTORS & MOTOR CONTROLLERS
SECTION 15170 MOTORS & MOTOR CONTROLLERS PART 1 GENERAL 1.01 SECTION INCLUDES A. Electric motors. B. Motor controllers for Packaged equipment. 1.02 SUBMITTALS A. Wiring diagrams with electrical characteristics
More informationForm 35 Malleable Iron Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.
NEC/CEC Suitable for use in the following Applications Serve as pulling fittings. Make bends in conduit system. Provide openings for splicing. Connect and change direction of conduit runs. Allow connections
More informationDENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES
PART 0 DESIGN STANDARDS 0.01 GENERAL DESIGN GUIDELINES A. Coordinate starter needs for mechanical equipment prior to 50% CD and confirm again for 100% CD submittal. B. Coordinate temperature controls requirements
More informationSECTION ENCLOSED CONTROLLERS
SECTION 16420 ENCLOSED CONTROLLERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification
More informationEnclosed Full-Voltage Starters
GE Energy Connections Made in USA Enclosed Full-Voltage Starters * www.geindustrial.com/products/starters GE Global Offer & Warranty starters utilize globally-rated IEC components which make it ideal for
More informationMOTOR TERMINAL CONNECTIONS
MOTOR TERMINAL CONNECTIONS Motor Classification Most of the industrial machines in use today are driven by electric motors Motors are classified according to the type of power used (AC or DC) and the motors
More informationCH215AFIT 2P 15A Arc Fault Shared Neutral/Indpndt Trip BRKR. Features. Dimensions and Weight. Descriptions. Manufacturer Information
Manufacturer Description Weight per unit Product Category CH2AFIT 2P A Arc Fault Shared /Indpndt Trip BRKR Eaton Corp Features Current Rating AMPERE Interrupting Rating 10 KILOAMPERE Poles 2 Terminal Type
More information1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D
Cl. I, Div. and 2, Groups B, C, D Cl. II, Div., Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 3, 4, 4*,, Ex d IIB + H2 T, IP Explosionproof Dust-Ignitionproof Raintight Wet Locations Applications:
More informationMulti-Pak Group Control
Multi-Pak Grouping.1 Product....................................... Application.................................... Features Enclosures........................................... V-T-2 V-T-2 V-T-2 Feeder
More informationNEMA Full Voltage Power Devices. Section 1. Control Catalog 1-1
NEMA Rated Full Voltage Power Devices Application Information and Technical Data (300-Line)...-4 Magnetic Nonreversing Starters (CR306, CR386) Basic Features (300-Line) and Technical Features (CR306, CR386)...-7
More information1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control
Contents Description Relays and Timers......................... Miniature Controls......................... Contactors and Starters.................... Thermal Overload Relays.................... C440/XT
More informationBulletin 190-M Compact Starters. Selection Guide
Bulletin 190-M Selection Guide Bulletin 190-M Selection Guide 3 Bulletin 190-M Compact Design to 45mm Wide Common Adapter for Panel or DIN Rail Mounting Pre-Wired Assembly All Control Terminations Located
More informationT&B EX TM Motor control
T&B EX TM Motor control Starters For across-the-line, manual, or magnetic motor starting, motor disconnect, motor and line protection, and stop-start operations, these starters will perform in hazardous
More information1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.
SECTION 262816 - ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Fusible switches. 2. Nonfusible switches. 3. Receptacle switches. 4. Shunt trip switches. 5.
More informationPOWERPLEX PANELBOARD 1
1 POWERPLEX PANELBOARD 2 ADVANCING PANELBOARD TECHNOLOGY WITH COMPONENT LEVEL PROTECTION. Introducing the PowerPlex Panelboard. Appleton's PowerPlex Panelboard changes the face of hazardous location panelboards
More informationREVISIONS App PC. App Sud. App Thom TC 2014/03/25
/9 Rev Description Document format and number changed. Previous number 543-0.0.30 Rev n by TC 204/03/25 Sud TC 204/03/25 REVISIONS PC Thom VB LH Clyd r Act Issue Date YYYY/MM/DD Pending Pending Pending
More informationProduct Selection 3-Pole Contactors
- Contactors and January 0 Vol., Ref. No. [06] Product Selection -Pole Contactors When Ordering Specify Select required contactor by Catalog Number and replace the magnet coil alpha designation in the
More information