Daikin McQuay. Roofpak Condensing Unit Medium Cabinet, Standalone Standard & Digital Compressor Models

Size: px
Start display at page:

Download "Daikin McQuay. Roofpak Condensing Unit Medium Cabinet, Standalone Standard & Digital Compressor Models"

Transcription

1 Replacement Parts List No Revision S 0/08 Daikin McQuay Roofpak Condensing Unit Medium Cabinet, Standalone Standard & Digital Compressor Models RCS Tons Vintage D Code = A, A, YA Unit Model Code 44= R, D To find your Daikin Applied parts distributor, call or visit

2 Contents Parts List Revision History... Nomenclature Serial Number... 4 Model Number... 4 Electrical Legend... 5 Condenser Section Notes... 6 Fan Deck- Unit Sizes D... 7, 8 Fan Deck- Unit Sizes D... 9, 0 Quiet Fan Assemblies: Code 47=, 4... Compressors & Compressor Components Unit Size 045D, 050D: Code 44= R OR D... Unit Size 060D, 06D: Code 44= R OR D... Unit Sizes D: Code 44= R... 4 Digital Compressors & Components: Code 44= R AND Code 60= XX OR Code 44= D... 5, 6 Control Box Notes... 7 Control Box Component Label Diagram... 8 Control Panel: (0/ & Earlier) Control Box Diagram... 9 Common Components... 0, Compressor Contactors and Motor Protectors Unit Size 045D Compressor MMP- 4 and Contactor M Unit Size 050D Compressor MMP- 4 and Contactor M Unit Size 060D, 06D Compressor MMP- 4 and Contactor M Unit Size 070D, 07D Compressor MMP- 6 and Contactor M Unit Size 075D Compressor MMP- 6 and Contactor M Condenser Fan MMP,,,,, and Contactors M- 4- Fantrol Units... 7 Condenser Fan MMP-, Contactors M- 4, Fuses F & F- Speedtrol Units... 8 Control Panel: (04/0 & Later) Control Box Diagrams... 9 Common Components... 0, Compressor Contactors and Motor Protectors 045D Compressor MMP- 4 and Contactor M D Compressor MMP- 4 and Contactor M D, 06D Compressor MMP- 4 and Contactor M D, 07D Compressor MMP- 6 and Contactor M D Compressor MMP- 6 and Contactor M Condenser Fan MMP,,,,, and Contactors M- 4- Fantrol Units... 8 Condenser Fan MMP-, Contactors M- 4, Fuses F & F- Speedtrol Units... 9 Pressure Manifolds D Pressure Manifolds D... 4 Factory Supplied Line Voltage Box: Code = YYYFY... 4 Tubing Valves, Filter Driers, Sight Glasses, & Hot Gas Bypass/Liquid Line Kits... 4 Critical Parts List... CPL Roofpak Standalone Condensing Unit; RCS Vintage D Rev. S 0/8 RPL / Page

3 Parts List Revision History Rev. Date Description A- P 08/6 Archived Revs. A- P. Q 06/7 Cover: Added Standard and Digital Compressor Models to form title. Master pg. Changed Condenser to Condensing Unit. Page 4: Added footnote #. Page 5: Updated Electrical Legend. Page 6 (NEW): Added pg. with Notes. Repaginated form & updated the TOC. Page 6, 8 (OLD) 7, 9 (NEW): Updated dwgs. Misc. updates. Rewrote footnotes. Page 7, 9 (OLD) 8, 0 (NEW): Updated p/ns & qtys. Rewrote footnotes. Page - 4 (OLD) -5 (NEW): Misc. updates. Rewrote footnotes. Page : Added footnote #. Page 5 (OLD) 8 (NEW): Rewrote footnotes & pg. Header. Moved 4/ & later dwg. to pg. (NEW). Page 6 (OLD): Deleted pg. Repaginated form and updated the TOC. Page 6, 7 (NEW): Added pg. for Digital Cmpr. p/ns. Repaginated the form & updated the TOC. Page 8 (NEW): Added pg. with Notes. Repaginated the form & updated the TOC. Page 8 (OLD) (NEW): Updated TD, description & p/n. Rewrote footnote # 4. Page 0-7 (OLD) - 0 (NEW): Updated dwgs. & p/ns. Page 8, 9 (OLD), (NEW): Updated/added misc. p/ns & descriptions. Rewrote footnotes. Page (NEW): Added pg. for MCBOX diagrams. Repaginated the form & updated the TOC. Page 0 (OLD) 4 (NEW): Updated/added misc. transformers & components. Page 4 (OLD 46 (NEW): Added/updated p/ns. Rewrote pg. header and footnotes. Updated the TOC. Page CPL (NEW): Added pg. for CPL. Repaginated the form & updated the TOC. R 09/7 Page 5: Deleted N/A PB4 info. Page 8: Rewrote Notes. Page, : Updated PB4 info. Deleted PB4 info. Updated PVM, p/ns as needed. S 0/8 Various: Deleted info re. RCS068. Only one unit was produced. Page 4, 6, 8 (OLD) 4, 5, 6 (NEW): Deleted pg. Repaginated the form & updated the TOC. Page 7, 8 (OLD) 6, 7 (NEW): Rewrote pg. header. Daikin Applied, 600 Industrial Park Blvd., P.O. Box 55, Minneapolis, MN (76) Roofpak Standalone Condensing Unit; RCS Vintage D Rev. S 0/8 RPL / Page

4 Plant Identification FBO = Faribault, MN U= Unit Nomenclature Serial Number FBO U Serial Number (build sequence) Month of Manufacture 0= January 05= May 0= February 06= June 0= March 07= July 04= April 08= August Year of Manufacture 08= = 009 0= 00 etc. Model Number RCS 050D Y Y Y Y EY D AL P A Y Y Y Y YP YYYY YY YY YYYY YYY YYYFY All Y s Code MY R Y All Y s YY YY All Y s AAY 047C Y B YY Code = September 0= October = November = December Codes 0-06= Always Y (Qty. 4) Code 07= Unit Approval Listings CY= ETL- Canada EY= ETL/MEA USA YY= None Code 08= Control Box Location D= Standard Code 09= Unit Voltage = 08/60/ 9= 0/60/ 7= 460/60/ 7= 575/60/ Code 0= Starting Option AL= Across- the- Line Code = Field Power Connection A= Single Disconnect w/through-the-door Mechanism. P= Single Power Block YY= None- Field wire to Fusing Code = Temperature Controls Package YA= No Temperature Controller, Standalone, Less Transformer A= No Temperature Controller, Standalone, 5V Transformer A= No Temperature Controller, Standalone, 4V Transformer Codes -6= Always Y (Qty. 4) Code 7= Miscellaneous Auxiliary Controls YP= Phase Failure YG= Ground Fault Protection YC= YP + YG YY= None Code 8= Misc. Control Functions AYYY, SYYY, YYYY= Misc. Control Functions Codes 9-= Always Y (Qty. ) Code = Miscellaneous Electrical Options YYYYY= Field Supplied 5V Power, Outlet by Factory YYYFY= Factory Supplied Line Voltage and Outlet **A**= ABB SpeedTrol Inverter **B**= Daikin Applied SpeedTrol Inverter **Q**= Schneider SpeedTrol Inverter Codes 4-4= Always Y (Qty. 65) Code 4= Compressor Capacity Control 4= 4 steps 6= 6 steps Note that there are some Digital Scroll Compressor units built as specials (Code 44= R AND Code 60= XX WITH Digital Scroll compressors listed as a special feature). For these units contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. Code 4= Condenser Options Digit Air Coil M= 5mm Micro Channel Coil P= 5mm Electrofin Coated Micro Channel Coil T= mm Micro Channel Coil U= mm Electrofin Coated Micro Channel Coil Y= None Digit Condenser Options G= Coil Guards, Steel S= Seal Tite Conduits B= G + S Y= None Code 44= Compressor Type R= Scroll R40a Code 45= Compressor Isolation = Resilient Rubber-in-Shear (RIS) Code 46= Hot Gas Bypass = HGBP Circuit # = HGBP Circuits # & Y= None Code 47= Low Ambient Operation = Fantrol = Speedtrol = Quiet Fan Fantrol 4= Quiet Fan w/ Speedtrol Code 48= IBC Seismic/Power Correction Capacitors Y= None Codes 49-54= Always Y (Qty. ) Code 55 Ultra High Efficiency Units HE= Ultra High Efficiency Unit YY= None Code 56= Chicago Refrigeration Service Valves CC= Chicago Code CV= Chicago Code w/ Valves YY= Service Valves Codes 57-60= Always Y (Qty. 4) Codes 6-64= Misc. Options, Packaging and Warranties Code 65= Unit Family Designation 047C= D Code 66= Always Y Code 67= ASHRAE Certification Y= None B= AHRI Certified C= AHRI Certified Code 68= Short Circuit Current Rating (SCCR) YY= None 0= 0 SCCR = SCCR 65= 65 SCCR Roofpak Standalone Condensing Unit; RCS Vintage D Rev. S 0/8 RPL / Page 4

5 Electrical Legend Schematic Sym. Description Location AFD/VFD, Inverters, Speedtrol Control Box CDT Digital Compressor Discharge Thermistor Condenser Section COMPR.- 6 Compressors Condenser Section CS, Control Switches Control Box DCC Digital Compressor Controller Control Box DS4 Disconnect Control Box DS6 Disconnect, Factory Powered Outlet 0V Service Panel FUA, B Fuses, Control Circuit, T Primary Control Box FUC Fuse, Control Circuit, T Secondary Control Box F6A, B Fuses, Transformer, (T6) Primary Condenser Section F6C Fuse, Transformer, (T6) Secondary Condenser Section F, Fuses, Speedtrol Inverter Control Box GFS4 Ground Fault Sensor Control Box GFR4 Ground Fault Relay Control Box GRD Ground Control Box HP, High Pressure Controls, Refrigerant Control Box Manifold HTR- 6 Crankcase Heaters On Compressors LP, Low Pressure Controls, Refrigerant Control Box Manifold LR, Line Reactors Control Box M- 6 Contactors, Compressors Control Box M- 5 Contactors, Condenser Fans, Circuit # Control Box M- 5 Contactors, Condenser Fans, Circuit # Control Box MJ Mechanical Jumpers Control Box MMP- 6 Manual Motor Protectors, Compressors Control Box MMP- 4 Manual Motor Protectors, Condenser Fans Ckt. Control Box MMP- 4 Manual Motor Protectors, Condenser Fans Ckt. Control Box MP- 6 Motor Protectors, Compressors On Compressors PB4 Power Block, Condenser Control Box PC, Switches- Fan Pressure Control Box Manifold PC9 Pressure Control, Split Coil Condenser Section PT, Pressure Transducers, SpeedTrol Control Box PT9 Pressure Transducer, Split Coil Condenser Section PVM4 Phase Voltage Monitor Control Box R, Relays, High Pressure Reset Control Box R5-8,, 4 Relays, Compressor, Safety/Cool Fail Control Box R, 7 Relays, Speedtrol Control Box R- 8 Relays, Compressor Contactor Staging Control Box R70-90 Relays, Digital Compressor Controller Control Box REC Receptacle, Condenser Box Control Box REC Receptacle, Field Power, 5VAC Bulkhead S Switch, System On/Off Control Box SPTRL Switch, Speedtrol Control Box Manifold SV7 Solenoid Valve, Digital Compressor Condenser Section SV9 Solenoid Valve, Split Coil Condenser Section T Transformer, Main Control Box T6 Transformer- 0V Factory Supplied Receptacle 0V Service Panel T9 Transformer- 0/4V Control Box T Transformer, Speedtrol, Line/40VAC Condenser Section T Transformer, Digital Cmpr. Controller, Line/5VAC Control Box T Transformer, Digital Compressor Controller, 5/4VAC Control Box TB- 6 Terminal Blocks Control Box TC- 4 Temperature Controls, FanTrol Condenser Section TD, Time Delays, Compressor Lockout Control Box TD9 Time Delay, Split Coil Control Box Roofpak Standalone Condensing Unit; RCS Vintage D Rev. S 0/8 RPL / Page 5

6 Condenser Section Notes Primary Codes that pertain: 09, 4, 4, 44, 47 The Condenser section houses the Compressors, Condenser Coils, Condenser Control Box, Pressure Controls, and Fan Deck. RCS units have the pressure controls mounted on the Control Box Manifold. SpeedTrol Inverters and Line Reactors are located in the Control Box. Note that a number of model changes were made in mid 0. The RCS060D was dropped in favor of the RCS06D; the 070D was replaced by the 07D; and the RCS075D was discontinued. Code 09, unit voltage, affects Compressor selection. Code 4 indicates Compressor capacity control. Code 4 determines if the Micro Channel Condenser Coils are coated or not, and if the unit is equipped with Coil/ Vandal Guards AND/OR Sealtite conduits. Code 44 shows the type of compressor selected. Code 44= R NORMALLY stands for units with ALL standard scroll compressors. However, starting in late 04, some units were built as specials with digital scroll compressors with Code 44= R AND Code 60= XX with digital scroll compressors listed as a special feature (refer to the drawing below for an example of Special Code String Text). Confirm the presence of a digital compressor BEFORE ordering to ensure that the correct part(s) are identified. Code 44= D also indicates the presence of digital compressors. Code 47 determines Condenser Fan operation: FanTrol [Standard operation] (Code 47=, ), or SpeedTrol [Low Ambient operation] (Code 47=, 4). If Code 47=, the unit is equipped with optional Quiet Fan assemblies and FanTrol. If Code 47= 4, the unit is equipped with optional Quiet Fan assemblies and SpeedTrol. NOTE: This form is to be used for RCS Standalone units only (Code = *A). For RCS D units when Code DOES NOT EQUAL *A refer to form # Roofpak Standalone Condensing Unit; RCS Vintage D Rev. S 0/8 RPL / Page 6

7 Condenser Section Fan Deck D Diagrams Fan Detail Motor Mount to Fan Panel Mounting Detail Fan Layout Detail 0 Fan # Fan # End of Unit Fan # Fan # 045, 050, 060D Fan Deck Detail CDF60 CDF50 Fan # Fan # Fan # Fan # Fan # CDF5 Fan # CDF5 MOTOR GND WIRE End of Unit 06 Fan Deck Detail 5 (045, 050, 060D shown) Roofpak Standalone Condensing Unit; RCS Vintage D Rev. S 0/8 RPL / Page 7

8 Condenser Section Fan Deck D Components Unit Size Ref. Part Part No. Description Number Condenser Coils Code 4= M* 5.5 x 7 6/ & Earlier x 7 7/ thru 5/ x 7 6/4 & Later Condenser Coils Code 4= T* 5.5 x Condenser Coils, Coated Code 4= P* 5.5 x 7 6/ & Earlier x 7 7/ thru 5/ x 7 /4 & Later Condenser Coils, Coated Code 4= U* 5.5 x Condenser Fan Motor Code 47=, FanTrol/SpeedTrol 08/0/ FanTrol/SpeedTrol Condenser Fan Deck Code 47=, 55 Panel- Blank NA NA NA 0 Top Panel Fan Propeller Motor Mount Grommet Spacer- Steel Screw- Cap Nut- Lock Washer, Narrow- Plain Washer, Wide- Plain Fan Guard N/S Vandal Guard Kit N/S= Not shown on Diagram. Due to production overlap, contact Daikin Applied with model and serial number information to ensure that the correct coil is identified. The original FanTrol motor (Code 47= ) is obsolete and no longer available. Use inverter duty motor for ALL applications when Code 47= OR. This is only one of two pieces that make up the Motor mount. For a complete Motor Mount, order a quantity of TWO per Motor. Quantity listed is the TOTAL for the unit. 08/0V 08/0V 460/V Roofpak Standalone Condensing Unit; RCS Vintage D Rev. S 0/8 RPL / Page 8

9 Condenser Section Fan Deck D Diagrams Fan Detail Motor Mount to Fan Panel Mounting Detail Fan Layout Detail 50 Fan # 55 End of Unit Fan # Fan # 070D Fan Deck Detail Fan # Fan # Fan # Fan # Fan # 4 Fan # 4 (075D shown) Fan # End of Unit Fan # 5 Fan # Fan # Fan # End of Unit 07, 075D Fan Deck Detail Roofpak Standalone Condensing Unit; RCS Vintage D Rev. S 0/8 RPL / Page 9

10 Condenser Section Fan Deck D Components Unit Size , 075 Ref. Part Part No. Description Number Condenser Coils Code 4= M* 5 x 84 6/ & Earlier x 84 7/ thru 5/ x 84 6/4 & Later Condenser Coils, Coated Code 4= P* x 84 7/ & Earlier x 84 8/ thru / x 84 /4 & Later Condenser Fan Motor Code 47=, FanTrol/SpeedTrol 08/0/ FanTrol/SpeedTrol Condenser Fan Deck Code 47=, 55 Panel, Blank Top Panel Fan Propeller Motor Mount Grommet Spacer- Steel Screw- Cap Nut- Lock Washer, Narrow- Plain Washer, Wide- Plain Fan Guard N/S Vandal Guard Kit N/S= Not shown on Diagram. Due to production overlap, contact Daikin Applied with model and serial number information to ensure that the correct coil is identified. The original FanTrol motor (Code 47= ) is obsolete and no longer available. Use inverter duty motor for ALL applications when Code 47= OR. This is only one of two pieces that make up the Motor mount. For a complete Motor Mount, order a quantity of TWO per Motor. Quantity listed is the TOTAL for the unit. 08/0V 08/0V 460/V Roofpak Standalone Condensing Unit; RCS Vintage D Rev. S 0/8 RPL / Page 0

11 Condenser Section Quiet Fan Assemblies Code 47=, 4 Ref. Part Part Unit Size No. Description Number Quiet Fan Assy. 08V V Panel, Blank NA Quiet Fan Assemblies are sold as assemblies ONLY. Individual components including the Motor, Fan Prop, Fan Guard, Motor Mount, and Fan Top Panel are NOT available separately. Roofpak Standalone Condensing Unit; RCS Vintage D Rev. S 0/8 RPL / Page

12 Condenser Section Standard Compressors & Compressor Components Unit Size 045D, 050D: Code 44= R OR D Side View Compressor Rail to Base Channel Mounting Detail (6 places) Compressor Rail Compressor Mounting Channel Standard Cmpr. Units Circuit # & AND Digital Scroll Cmpr. Units: Circuit # Unit Size Ref. Part Part No. Description Number Compressors 0HP Compressors 0HP Compressors 0HP Compressors HP Compressors HP Compressors HP Grommet Sleeve Screw Washer- Plain Washer- Lock Junction Box- Compressor Heater- Crankcase Screw- Junction Box Gasket- Junction Box NOTE: Quantities listed are for the unit. Compressors are factory mounted in TANDEM assemblies, but REPLACEMENT COMPRESSORS ARE AVAILABLE AS SINGLE COMPRESSORS ONLY as shown above. A Tandem compressor is two compressors piped together in one assembly. There are two tandems per unit (one on each circuit). When replacing a single compressor out of a Tandem assembly, the original piping is reused. 4 feet per junction box. Note that there are some Digital Scroll Compressor units built as specials (Code 44= R AND Code 60= XX WITH Digital Scroll compressors listed as a special feature). Digital Compressors are ALWAYS located in Circuit #. For these units refer to the Digital Compressors & Components page at the end of this section. 08/0V 08/0V Roofpak Standalone Condensing Unit; RCS Vintage D Rev. S 0/8 RPL / Page

13 Condenser Section Standard Compressors & Compressor Components Unit Size 060D, 06D: Code 44= R OR D Side View Compressor Rail to Base Channel Mounting Detail (6 places) 07 Compressor Rail or Compressor Mounting Channel Standard Cmpr. Units Circuit # & AND Digital Scroll Cmpr. Units: Circuit # Size 060,06 Ref. Part Part No. Description Number, Compressors 4/4 & Earlier Compressors 5/4 & Later Compressors 4/4 & Earlier Compressors 5/4 & Later Compressors 4/4 & Earlier Compressors 5/4 & Later Grommet Sleeve Screw Washer- Plain Washer- Lock Heater- Crankcase NOTE: Quantities listed are for the unit. Compressors are factory mounted in TANDEM assemblies, but REPLACEMENT COMPRESSORS ARE AVAILABLE AS SINGLE COMPRESSORS ONLY as shown above. A Tandem compressor is two compressors piped together in one assembly. There are two tandems per unit (one on each circuit). When replacing a single compressor out of a Tandem assembly, the original piping is reused. Note that there are some Digital Scroll Compressor units built as specials (Code 44= R AND Code 60= XX WITH Digital Scroll compressors listed as a special feature). Digital Compressors are ALWAYS located in Circuit #. For these units refer to the Digital Compressors & Components page at the end of this section. 08/0V Roofpak Standalone Condensing Unit; RCS Vintage D Rev. S 0/8 RPL / Page

14 or 45 Condenser Section Standard Compressors & Compressor Components Unit Sizes D: Code 44= R Side View Discharge Tubing Top View Gas Tubing Suction Tubing Circuit # Comp. # Comp. # Comp. #5 Circuit # Comp. # Comp. # Comp. #5 or or or or or or or or Circuit # Comp. # Comp. #4 Comp. #6 Circuit # Comp. # Comp. #4 Comp. #6 Compressor to Compressor Rail Mounting Detail Compressor Rail to Base Channel Mounting Detail (8 places) Compressor Rail Compressor Mounting Channel Unit Size 070, Ref. Part Part No. Description Number, Compressors- Circuits # or 0HP Compressors- Circuits # or 0HP Compressors- Circuits # or 0HP Compressors- Circuits # or HP Compressors- Circuits # or HP Compressors- Circuits # or HP Grommet Sleeve Screw Washer- Plain Washer- Lock Sight Glass- Gas Line Junction Box- Compressor Fitting- Rotolock Heater- Crankcase Screw- Junction Box Gasket- Junction Box Rail- Trio Compressor Mounting Spacer Screw Washer feet per junction box. 08/0V 08/0V Roofpak Standalone Condensing Unit; RCS Vintage D Rev. S 0/8 RPL / Page 4

15 Condenser Section Digital Compressors & Components, Circuit #, Unit Size 045D- 06D: Code 44= R AND Code 60= XX OR Code 44= D, Digital Compressor Detail Compressor Rail to Base Channel Mounting Detail /0V Unit Size Ref. Part Part No. Description Number 0 Compressor- Digital, Circuit # Compressor- Digital, Circuit # Compressor- Digital, Circuit # Compressor- Digital, Circuit # Compressor- Digital, Circuit # Compressor- Digital, Circuit # Compressor- Digital, Circuit # 0 Thermistor- Discharge (CDT) Compressor Mounting Kit N/S Heater- Crankcase N/S Heater- Crankcase Kit- Unloader Coil, 0V (SV7) NOTE: Quantities listed are for the unit. N/S= Not shown on diagram. There are some Digital Scroll Compressor units built as specials (Code 44= R AND Code 60= XX) WITH Digital Scroll compressors listed as a special feature (refer to the Notes page at the beginning of this section for more information). Digital Compressors are ALWAYS located in Circuit #. Compressors are factory mounted in TANDEM assemblies, but REPLACEMENT COMPRESSORS ARE AVAILABLE AS SINGLE COMPRESSORS ONLY as shown above. A Tandem compressor is two compressors piped together in one assembly. There are two tandems per unit. When replacing a single compressor out of a Tandem assembly, the original piping is reused. For unit sizes/voltages not shown contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified. 08/0V 08/0V Roofpak Standalone Condensing Unit; RCS Vintage D Rev. S 0/8 RPL / Page 5

16 Condenser Section Digital Compressors & Components, Circuit #, Unit Size 045D- 06D: Code 44= R AND Code 60= XX OR Code 44= D Control Box Detail Unit Size Ref. Part Part No. Description Number FA, B Fuse- T Primary 08V FC Fuse- T Secondary 4EHG766 T Transformer- 5/4V 08V N/S Cover- Terminals N/S Cover/Fuseholder T Transformer- 5/4VAC N/S= Not shown on diagram. There are some Digital Scroll Compressor units built as specials (Code 44= R AND Code 60= XX) WITH Digital Scroll compressors listed as a special feature (refer to the Notes page at the beginning of this section for more information). Digital Compressors are ALWAYS located in Circuit #. For voltages not shown contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified. Roofpak Standalone Condensing Unit; RCS Vintage D Rev. S 0/8 RPL / Page 6

17 Notes Primary Codes that pertain: 09,,, 7, 8,, 47, 68 In March and April of 0, the Condenser Control Box underwent a major redesign. This design change not only changed components, but some Contactor, Motor Protector, and VFD circuiting changed. Note that components and component accessories such as Auxiliaries, Links, etc. are NOT interchangeable. For units built and shipped during the transition, confirm which design was used, or contact Daikin Applied to ensure that the correct part(s) are identified. Code 9 determines unit voltage and affects the Transformers, Motor Protectors/MMPs, Contactors, Fuses, etc. Code determines whether the main power connection is a Terminal Block or a through-the-door Disconnect Switch. For Stand Alone Condensing Units Code is ALWAYS A, A, or YA. This indicates that the unit is NOT equipped with factory mounted controls, but instead has a Transformer (Code = A, A) and Control Relays OR just Control Relays (Code = YA). For information specific to RCS units equipped with a factory mounted MicroTech controller OR Floating Point Control (RCS D units when Code DOES NOT= *A), refer to RPL form Code 7, 8, and determine miscellaneous electrical options including whether the unit has a Freezestat, PVM (Phase Voltage Monitor), Ground Fault Protector, SpeedTrol Inverters, and/or a factory mounted Service Outlet. Code 47 determines Condenser Fan operation: FanTrol [Standard operation] (Code 47=, ), or SpeedTrol [Low Ambient operation] (Code 47=, 4). If Code 47=, the unit is equipped with optional Quiet Fan assemblies and FanTrol. If Code 47= 4, the unit is equipped with optional Quiet Fan assemblies and SpeedTrol. Code 68 specifies the SCCR or Short Circuit Current Rating for the unit. Standard units are always rated at 0 SCCR (Code 68= 0, OR no entry). An entry with any other rating (Eg: Code 68=, 65 OR indicated in the specials description in the Code String lookup) may change disconnect switches, circuit breakers, fuses, and other miscellaneous components. When control box parts are required for units with nonstandard SCCR ratings, contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. NOTE: This form is to be used for RCS Standalone units only (Code = *A). For RCS D units when Code DOES NOT EQUAL *A refer to form # Roofpak Standalone Condensing Unit; RCS Vintage D Rev. S 0/8 RPL / Page 7

18 Control Box Component Label Diagram Note that starting in late 00 all units will have a label similar to the one shown above pasted to the inside of the Control Box door. This label contains schematic designators, part descriptions, and Daikin Applied part numbers. The label shown above is for representative purposes only. Actual part numbers will vary depending upon unit size and options selected. Roofpak Standalone Condensing Unit; RCS Vintage D Rev. S 0/8 RPL / Page 8

19 Diagram: (/ & Earlier), PL5-0 For information on RCS units WITH controls (Code = *E, *F), OR with no Temperature controls and floating point control (Code = YM), refer to form # The above diagram shows a typical RCS Standalone Unit Control Box layout and is to be used for reference only. Specific unit configuration may differ depending upon unit size and options selected. Roofpak Standalone Condensing Unit; RCS Vintage D Rev. S 0/8 RPL / Page 9

20 Common Components: (/ & Earlier) Sch. Part Part Qty. Sym. Description Number Switches- Control CS, Switch- Control- Pole Code = A Switch- Control- Pole Code = A S Switch- System Receptacle REC Receptacle Relays R, Relay- Hi Pressure Reset R5. Relay- Safety R6. Relay- Safety R7. Relay- Safety R8. Relay- Safety R Relay- Inverter AFD Code 47= R. Relay- Safety R4. Relay- Safety R7 Relay- Inverter AFD Code 47= R- R6 Relay- Compressor Contactor Staging Code = A /comp Time Delays TD, Time Delays, Compr. Lockout 4 Temp. Controls TC Temperature Control- Fantrol TC4 Temperature Control- Fantrol Ground Fault Protection Code 7= YG, YC GFR4 Ground Fault Relay- SPDT GFS4 Ground Fault Sensor Phase Voltage Monitor Code 7= YP, YC PVM4 Phase Voltage Monitor 08/0/ Units 000 Units 000 Plugs PL5-0 Plug- Pin /comp Terminal Blocks TB,,5,6,8 Terminal Block var. Transformers T Transformer- Main T9 Transformer- 5/4VAC Speedtrol Inverters Code 47= AFD, Inverter 08/0V Inverter Inverter Speedtrol Line Reactors Code 47= LR, Line Reactor Code 09= Part number is for one section. Quantity of sections varies with unit options. Ground Terminal is p/n Jumpers for TB are p/n (TBA:5), (TBB:4), (TBC:0,TBD:5 & TBE:0). Each relay uses a socket p/n See following page. 4 Two Time Delay relays have been furnished. The most common is the NON-Adjustable type p/n The ADJUSTABLE version of this relay could also have been supplied: p/n Confirm which relay is required BEFORE ordering. Roofpak Standalone Condensing Unit; RCS Vintage D Rev. S 0/8 RPL / Page 0

21 Common Components: (/ & Earlier), Continued Sch. Part Part Qty. Sym. Description Number Disconnect Code = A, A DS4 Switch- Disconnect 00A Handle- Disconnect Shaft Mod Lug- Ground Switch- Disconnect 50A Handle- Disconnect Shaft Mod Lug- Ground Switch- Disconnect 50A Handle- Disconnect Shaft Mod Lug- Ground Switch- Disconnect 400A Handle- Disconnect Shaft Mod Lug- Ground Switch- Disconnect 600A Handle- Disconnect Shaft Mod Lug- Ground Power Block- Main PB4 Main 75A A, 40A A Any of the listed parts may be used, depending on unit options. Check installed part to verify, or contact Daikin Applied with unit serial and/or GO number to ensure correct replacement is selected. The original Disconnect Switch and related parts are obsolete. Due to dimensional differences minor field modifications may be required for proper installation. T Transformer and Fusing Sch. Part Part Sym. Description Number T Transformer- Main Transformer- Main Transformer- Main FUA, B Fuse- T Transformer, Primary Fuse- T Transformer, Primary Fuse- T Transformer, Primary Fuse- T Transformer, Primary FUC Fuse- T Transformer, Secondary 0475 N/S Cover- Fuse N/S Puller- Fuse N/S= Not shown on diagram. 08V 0V Roofpak Standalone Condensing Unit; RCS Vintage D Rev. S 0/8 RPL / Page

22 Compressor MMP- 4 and Contactor M- 4: (/ & Earlier) Unit Size 045D Front Mounted A Front Mounted A MMP MMP B Link A Spacer Contactor Contactor MMP- 4 & M- 4 Contactor Link Detail 08, 0V MMP- 4 & M- 4 Contactor Link Detail 460, Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts M- 4 Contactor- Compressor 50A Contactor- Compressor 40A Contactor- Compressor 5A A Spacer B Link Compressor MMP s & Parts MMP- 4 Manual Motor Protector- Compressor Manual Motor Protector- Compressor Manual Motor Protector- Compressor A Front Mtd. - NO AND NC Front Mtd. - NO OR NC In mid 00 the original cabled Contactor became obsolete and no longer available. The replacement Contactor listed mounts directly to the MMP as shown in the above diagram. When replacing ANY part of an old assembly, a new Contactor and MMP MUST be ordered as new and old parts are not interchangeable V 0V Roofpak Standalone Condensing Unit; RCS Vintage D Rev. S 0/8 RPL / Page

23 Compressor MMP- 4 and Contactor M- 4: (/ & Earlier) Unit Size 050D Front Mounted A Front Mounted A MMP MMP B Link A Spacer Contactor Contactor MMP- 4 & M- 4 Contactor Link Detail 08/0V MMP- 4 & M- 4 Contactor Link Detail 460, Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts M- 4 Contactor- Compressor 65A Contactor- Compressor 5A A Spacer B Link Compressor MMP s & Parts MMP- 4 Manual Motor Protector- Compressor Manual Motor Protector- Compressor Manual Motor Protector- Compressor A Front Mtd. - NO AND NC Front Mtd. - NO OR NC In mid 00 the original cabled Contactor became obsolete and no longer available. The replacement Contactor listed mounts directly to the MMP as shown in the above diagram. When replacing ANY part of an old assembly, a new Contactor and MMP MUST be ordered as new and old parts are not interchangeable V 0V Roofpak Standalone Condensing Unit; RCS Vintage D Rev. S 0/8 RPL / Page

24 Compressor MMP- 4 and Contactor M- 4: (/ & Earlier) Unit Size 060D, 06D Front Mounted A Front Mounted A 4 MMP or B MMP A Spacer Link Contactor or Front Mounted C Contactor or MMP- 4 & M- 4 Contactor Link Detail 08, 0V Unit Size 060, 06 MMP- 4 & M- 4 Contactor Link Detail 460, Unit Size 060, Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts M, Contactor- Compressor 65A 9468 M, Contactor- Compressor 40A 9468 M, Contactor- Compressor A 499 A Spacer B Link C Front Mtd. - NO AND NC M, 4 Contactor- Compressor 65A 9468 M, 4 Contactor- Compressor A 499 Compressor MMP s & Parts MMP, Manual Motor Protector- Compr Manual Motor Protector- Compr Manual Motor Protector- Compr Manual Motor Protector- Compr MMP, 4 Manual Motor Protector- Compr Manual Motor Protector- Compr Manual Motor Protector- Compr A Front Mtd. - NO AND NC Front Mtd. - NO OR NC In mid 00 the original cabled Contactor became obsolete and no longer available. The replacement Contactor listed mounts directly to the MMP as shown in the above diagram. When replacing ANY part of an old assembly, a new Contactor and MMP MUST be ordered as new and old parts are not interchangeable. Contact Daikin Applied with model and serial number information so that the correct part can be identified. Note that Size 06D replaced 060D units in mid 0. 08/0V 08/0V Roofpak Standalone Condensing Unit; RCS Vintage D Rev. S 0/8 RPL / Page 4

25 Compressor MMP- 6 and Contactor M- 6: (/ & Earlier) Unit Size 070D, 07D Front Mounted A MMP 4 or Front Mounted A B Link MMP or 4 A Spacer Contactor or Contactor or MMP- 6 & M- 6 Contactor Link Detail 08, 0V Unit Size 070, 07 MMP- 6 & M- 6 Contactor Link Detail 460, Unit Size 070, Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts M,, 5 Contactor- Compressor 50A 9468 Contactor- Compressor 40A 9468 Contactor- Compressor 5A 499 A Spacer B Link M, 4, 6 Contactor- Compressor 50A 9468 Contactor- Compressor 40A 9468 Contactor- Compressor 5A 499 Compressor MMP s & Parts MMP,, 5 Manual Motor Protector- Compr Manual Motor Protector- Compr Manual Motor Protector- Compr MMP, 4, 6 Manual Motor Protector- Compr Manual Motor Protector- Compr Manual Motor Protector- Compr A Front Mtd. - NO AND NC Front Mtd. - NO OR NC In mid 00 the original cabled Contactor became obsolete and no longer available. The replacement Contactor listed mounts directly to the MMP as shown in the above diagram. When replacing ANY part of an old assembly, a new Contactor and MMP MUST be ordered as new and old parts are not interchangeable. Note that Size 07D replaced 070D sized units in mid 0. Size 07D is a Standalone unit only (Code = *A). 08 0V 08V 0V Roofpak Standalone Condensing Unit; RCS Vintage D Rev. S 0/8 RPL / Page 5

26 Compressor MMP- 6 and Contactor M- 6: (/ & Earlier) Unit Size 075D Front Mounted A Front Mounted A MMP MMP B A Spacer Link Contactor Contactor MMP- 6 & M- 6 Contactor Link Detail 08V MMP- 6 & M- 6 Contactor Link Detail 460, Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts Contactor- Compressor 65A M- 6 Contactor- Compressor 5A A Spacer B Link Compressor MMP s & Parts MMP- 6 Manual Motor Protector- Compr Manual Motor Protector- Compr Manual Motor Protector- Compr A Front Mtd. - NO OR NC In mid 00 the original cabled Contactor became obsolete and no longer available. The replacement Contactor listed mounts directly to the MMP as shown in the above diagram. When replacing ANY part of an old assembly, a new Contactor and MMP MUST be ordered as new and old parts are not interchangeable V Roofpak Standalone Condensing Unit; RCS Vintage D Rev. S 0/8 RPL / Page 6

27 Condenser Fan MMP,,,,, & Contactors M- 4: (/ & Earlier) Fantrol Units (Code 47=, ) MMP 8 8 MMP Link 8B 8B Link 7 One Contactor Arrangement 7A Spacer Contactor 8C Bus Bar Contactor 7 7A Spacer Two Contactor Arrangement , 075 Ref. Sch. Part Part No. Symbol Description Number Fan Contactors/Parts 7 M- 4 Contactor- Cond. Fan A Spacer Fan MMP s & Parts 8 MMP- MMP- Fantrol Code 47= Code 47= Code 47= Code 47= Code 47= 4 Code 47= Code 47= Code 47= B Link- MMP C Bus Bar /0V 08/0V 08/0V Roofpak Standalone Condensing Unit; RCS Vintage D Rev. S 0/8 RPL / Page 7

28 Condenser Fan MMP-, Contactors M- 4, Fuses F & F: (/ & Earlier) Speedtrol Units (Code 47= ) MMP & Contactors Detail Speedtrol Fuses MMP 8 MMP 8 Adapter 9C Link 8B Puller 8C 9B Link Contactor 8A 7 7A Spacer Bus Bar Contactor 7 7A Spacer Fuse 9A 9 Fuse Block One Contactor Arrangement Two Contactor Arrangement F, F Ref. Schematic Part Part No. Symbol Description Number Fan Contactors 7 M- 4 Contactor A Spacer Fan MMP s & Parts 8 MMP MMP- Cond. Fan MMP- Cond. Fan MMP- Cond. Fan MMP- Cond. Fan MMP MMP- Cond. Fan MMP- Cond. Fan MMP- Cond. Fan MMP- Cond. Fan MMP- Cond. Fan MMP MMP- Cond. Fan MMP- Cond. Fan MMP- Cond. Fan MMP- Cond. Fan MMP MMP- Cond. Fan MMP- Cond. Fan MMP- Cond. Fan MMP- Cond. Fan MMP- Cond. Fan 8B Link- MMP C Bus Bar 4994 Speedtrol Fusing 9 F, Fuse Block A F, Fuse- Speedtrol Fuse- Speedtrol Fuse- Speedtrol Fuse- Speedtrol B Fuse Cover/Puller C DIN Rail Adapter Contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. 08V 0V 08V 0V 08V 0V 08V 0V Roofpak Standalone Condensing Unit; RCS Vintage D Rev. S 0/8 RPL / Page 8

29 Diagrams: (4/ & Later), RCS Stand Alone unit w/ Standard Compressors PL5-0 RCS Stand Alone unit w/ a Digital Compressor T DCC PVM4 T6 F6C FA FB FC PL5-0 CS REC DS4 MMP4 MMP T TB8 VFD VFD TD TD T F F TD9 For information on RCS units WITH controls (Code = *E, *F), OR with no Temperature controls and floating point control (Code = YM), refer to form # The above diagrams show typical RCS Standalone Unit Control Box layouts and are to be used for reference only. Specific unit configuration may differ depending upon unit size and options selected. Roofpak Standalone Condensing Unit; RCS Vintage D Rev. S 0/8 RPL / Page 9

30 Common Components: (4/ & Later) Sch. Part Part Qty. Sym. Description Number Digital Compressor Controller DCC Digital Compressor Controller Switches- Control CS, Switch- Control- Pole Code = A Switch- Control- Pole Code = A S Switch- System Receptacle REC Receptacle Relays R, Relay- Hi Pressure Reset R5 Relay- Safety R6 Relay- Safety R7 Relay- Safety R8 Relay- Safety R Relay- Inverter AFD Code 47=, R Relay- Safety R4 Relay- Safety R7 Relay- Inverter AFD Code 47=, R- R6 Relays- Compressor Contactor Staging Code = A 9947 /comp R70-90 Relays- Digital Compressor var. Time Delays TD, Time Delays, Compr. Lockout 6 TD9 Time Delay, Coil Splitter Temp. Controls TC Temperature Control- Fantrol TC4 Temperature Control- Fantrol Ground Fault Protection Code 7= YG, YC GFR4 Ground Fault Relay- SPDT GFS4 Ground Fault Sensor Phase Voltage Monitor Code 7= YP, YC PVM4 08/0/ (/6 & Earlier) 000 (/6 & Earlier) /0/ (/7 & Later) (/7 & Later) Socket, PVM (/7 & Later) Terminal Blocks TB,,5,6,8 Terminal Block var. TB5 Terminal Block Assy TB6 Terminal Block Assy Transformers T9 Transformer- 5/4VAC Part number is for one section. Quantity of sections varies with unit options. Ground Terminal is p/n Jumpers for TB are p/n (TBA:5), (TBB:4), (TBC:0,TBD:5 & TBE:0). Each relay uses a socket p/n For T,, Transformers see one page after next. 4 The replacement VFD Keypad is p/n For replacement VFD components, contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. 6 Two Time Delay relays have been furnished. The most common is the NON-Adjustable type p/n The ADJUSTABLE version of this relay could also have been supplied: p/n Confirm which relay is required BEFORE ordering. Roofpak Standalone Condensing Unit; RCS Vintage D Rev. S 0/8 RPL / Page 0

31 Common Components: (4/ & Later), Continued Sch. Part Part Qty. Sym. Description Number Speedtrol Inverters Code 47= AFD, 08/0V Inverter Code = **A, **B** Inverter Code = **Q** Inverter Code = **A, **B** Inverter Code = **Q** Speedtrol Line Reactors Code 47= LR, Line Reactor Code 09= Disconnect Switch Code = A, A DS4 Switch- Disconnect Switch- 00A Handle 940 Shaft Switch- 50A Handle 940 Mechanism Shaft Lugs Switch- 50A Handle Mechanism Shaft Lugs Switch- 400A Handle Mechanism Shaft Lugs Switch- 600A Handle Mechanism Shaft Lugs Plugs PL5-0 Plug- Pin /comp Power Block PB4 Main 75A A, 40A A Disconnects AND Power Blocks are sized according to various unit specifications. Check installed part to verify the correct size, or contact Daikin Applied with model and serial number information so that the required part(s) can be identified. This shaft is 4.5 OAL and is designed to be cut to length in the field. This shaft is 7. (8mm) OAL and is designed to be cut to length in the field. For a 9.69 (500mm) OAL use p/n Three Lugs are included with each p/n. Roofpak Standalone Condensing Unit; RCS Vintage D Rev. S 0/8 RPL / Page

32 Common Components: (4/ & Later), Continued T Transformer and Fusing Sch. Part Part Sym. Description Number Transformer- Main Control T Transformer ALL Sizes 000VA ALL Sizes 000VA ALL Sizes 000VA N/S Cover Kit, Terminal N/S Cover Kit, Fuseholder Fuses, T Transformer FUA, B Fuse- T Transformer, Primary FUC Fuse- T Transformer, Secondary N/S= Not shown on diagram. Contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified. 08V 0V T, Digital Compressor Transformers and Fusing Sch. Part Part Sym. Description Number FA, B Fuse- T Primary Fuse- T Primary Fuse- T Primary FC Fuse- T Secondary 4EHG766 T Transformer- 5/4V Transformer- 5/4V Transformer- 5/4V N/S Cover- Terminals N/S Cover/Fuseholder T Transformer- 5/4VAC N/S= Not shown on diagram. Contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified. 08V 0V Roofpak Standalone Condensing Unit; RCS Vintage D Rev. S 0/8 RPL / Page

33 Compressor MMP- 4 and Contactor M- 4: (4/ & Later) Unit Size 045D MMP Front Mtd. MMP Front Mtd. B Link Link B A Spacer Contactor Front Mtd. A Contactor MMP- 4 & M- 4 Contactor Link Detail 08/0/ MMP- 4 & M- 4 Contactor Link Detail Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts M- 4 Contactor- Compressor 40A Contactor- Compressor A Contactor- Compressor 5A A Front Mtd. - NO- NC Compressor MMP s & Parts Front Mtd. - NO AND NC Front Mtd. - NO AND NC MMP- 4 Motor Protector- Compressor 6-45A Motor Protector- Compressor 8-40A Motor Protector- Compressor 4-0A Motor Protector- Compressor - 6A B Link Link N/S Busbar Busbar N/S Busbar Feeder Terminal Busbar Feeder Terminal N/S= Not Shown on Diagram. 08v 045 0V Roofpak Standalone Condensing Unit; RCS Vintage D Rev. S 0/8 RPL / Page

34 Compressor MMP- 4 and Contactor M- 4: (4/ & Later) Unit Size 050D MMP Front Mtd. Front Mtd. MMP Link B Front Mtd. A Contactor MMP Link B A Contactor Spacer MMP- 4 & M- 4 Contactor Link Detail 08/0V MMP- 4 & M- 4 Contactor Link Detail Front Mtd. B Link Contactor A Front Mtd. MMP- 4 & M- 4 Contactor Link Detail Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts M- 4 Contactor- Compressor 65A Contactor- Compressor A Contactor- Compressor 5A A Front Mtd. - NO AND NC Compressor MMP s & Parts Front Mtd. - NO AND NC Front Mtd. - NO AND NC MMP- 4 Motor Protector- Compressor 45-6A Motor Protector- Compressor 7- A Motor Protector- Compressor 4-0A B Link Link Link N/S Busbar, position Busbar, position N/S Busbar Feeder Terminal Busbar Feeder Terminal N/S= Not Shown on Diagram. 08V 050 0V Roofpak Standalone Condensing Unit; RCS Vintage D Rev. S 0/8 RPL / Page 4

35 Compressor MMP- 4 and Contactor M- 4: (4/ & Later) Unit Size 060D, 06D Front Mtd. MMP Front Mtd. MMP Link B Front Mtd. A Contactor Front Mtd. A B Link Contactor MMP- 4 & M- 4 Contactor Link Detail 08/0V MMP- 4 & M- 4 Contactor Link Detail 460/ 060, 06 Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts M- 4 Contactor- Compressor 65A Contactor- Compressor 40A Contactor- Compressor 5A A Front Mtd. - NO AND NC Compressor MMP s & Parts Front Mtd. - NO AND NC MMP- 4 Motor Protector- Compressor 45-6A Motor Protector- Compressor - A Motor Protector- Compressor 8-5A B Link Link N/S Busbar, position N/S Busbar Feeder Terminal N/S= Not Shown on Diagram. 08V 0V Roofpak Standalone Condensing Unit; RCS Vintage D Rev. S 0/8 RPL / Page 5

36 Compressor MMP- 6 and Contactor M- 6: (4/ & Later) Unit Size 070D, 07D MMP Front Mtd. Front Mtd. MMP Link B Front Mtd. A B Link A Spacer Contactor Contactor MMP- 6 & M- 6 Contactor Link Detail 08/0/ MMP- 6 & M- 6 Contactor Link Detail 070, 07 Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts M- 6 Contactor- Compressor 40A Contactor- Compressor A Contactor- Compressor 5A A Front Mtd. - NO AND NC Compressor MMP s & Parts Front Mtd. - NO AND NC Front Mtd. - NO AND NC MMP- 6 Motor Protector- Compressor 6-45A Motor Protector- Compressor 8-40A Motor Protector- Compressor 4-0A Motor Protector- Compressor - 6A B Link Link N/S Busbar, position Busbar, position N/S Busbar Feeder Terminal Busbar Feeder Terminal N/S= Not Shown on Diagram. 08V 0V Roofpak Standalone Condensing Unit; RCS Vintage D Rev. S 0/8 RPL / Page 6

37 Compressor MMP- 6 and Contactor M- 6: (4/ & Later) Unit Size 075D MMP Front Mtd. Front Mtd. MMP Link B Front Mtd. Contactor MMP Link B A Contactor Spacer MMP- 6 & M- 6 Contactor Link Detail 08/0V MMP- 6 & M- 6 Contactor Link Detail Front Mtd. B Link Contactor A Front Mtd. MMP- 6 & M- 6 Contactor Link Detail Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts M- 6 Contactor- Compressor 65A Contactor- Compressor A Contactor- Compressor 5A A Front Mtd. - NO AND NC Compressor MMP s & Parts Front Mtd. - NO AND NC Front Mtd. - NO AND NC MMP- 6 Motor Protector- Compressor 45-6A Motor Protector- Compressor 7- A Motor Protector- Compressor 4-0A B Link Link Link N/S Busbar, position Busbar, position N/S Busbar Feeder Terminal Busbar Feeder Terminal N/S= Not Shown on Diagram. 08V 075 0V Roofpak Standalone Condensing Unit; RCS Vintage D Rev. S 0/8 RPL / Page 7

38 Condenser Fan MMP,,,,, & Contactors M- 4: (4/ & Later) Fantrol Units (Code 47= ) MMP 8 Link 7B 7 Contactor Ref. Schematic Part Part No. Symbol Description Number Cond. Fan Contactors 7 M - 4 M - 4 Contactor- Cond. Fan Fan MMP s & Parts 7B Link- MMP MMP Motor Protector 9549 Motor Protector Motor Protector Motor Protector MMP Motor Protector 9549 Motor Protector Motor Protector Motor Protector MMP Motor Protector 9549 Motor Protector Motor Protector Motor Protector MMP4 Motor Protector 9549 Motor Protector Motor Protector Motor Protector MMP Motor Protector 9549 Motor Protector Motor Protector Motor Protector MMP Motor Protector 9549 Motor Protector Motor Protector Motor Protector MMP Motor Protector 9549 Motor Protector Motor Protector Motor Protector MMP4 Motor Protector 9549 Motor Protector Motor Protector Motor Protector N/S Bus Bar, Position Bus Bar, Position Bus Bar, 4 Position N/S Bus Bar Top Feed N/S= Not Shown on Diagram. 08V 0V 08V 0V 08V 0V Roofpak Standalone Condensing Unit; RCS Vintage D Rev. S 0/8 RPL / Page 8

Daikin McQuay. Roofpak Condensing Unit Small Cabinet, Standalone Standard & Digital Compressor Models

Daikin McQuay. Roofpak Condensing Unit Small Cabinet, Standalone Standard & Digital Compressor Models Replacement Parts List No. 70009700 Revision M 0/08 Daikin McQuay Roofpak Condensing Unit Small Cabinet, Standalone Standard & Digital Compressor Models RCS 05-040 Vintage D Code = A, A, YA Code 44= R,

More information

McQuay. Air-Cooled Global Reciprocating Condensing Unit. ACR Vintage A. Last Manufactured: 2003

McQuay. Air-Cooled Global Reciprocating Condensing Unit. ACR Vintage A. Last Manufactured: 2003 Replacement Parts List No. 110504800 Revision G 04/2016 McQuay Air-Cooled Global Reciprocating Condensing Unit ACR 060-120 Vintage A Last Manufactured: 2003 To find your Daikin Applied parts distributor,

More information

McQuay Air-Cooled Reciprocating Chiller ALR

McQuay Air-Cooled Reciprocating Chiller ALR Replacement Parts List No. 057115200 Revision S 07/2015 McQuay Air-Cooled Reciprocating Chiller ALR Sizes 010-185 Vintage D Last Manufactured: 2000 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Evaporative Condenser Cooled Chiller. EGR Vintage A. Last Manufactured: Replacement Parts List No Revision B 07/2010

McQuay. Evaporative Condenser Cooled Chiller. EGR Vintage A. Last Manufactured: Replacement Parts List No Revision B 07/2010 Replacement Parts List No. 700015100 Revision B 07/2010 McQuay Evaporative Condenser Cooled Chiller EGR 060-240 Vintage A Last Manufactured: 2004 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay Climate Control. Water Source Heat Pump. CC, CG Vintage E, F, G. Last Manufactured: 1986

McQuay Climate Control. Water Source Heat Pump. CC, CG Vintage E, F, G. Last Manufactured: 1986 Replacement Parts List No. 110508600 Revision C 12/2008 McQuay Climate Control Water Source Heat Pump CC, CG 750-1000 Vintage E, F, G Last Manufactured: 1986 To find your Daikin Applied parts distributor,

More information

McQuay. Reciprocating Condensing Unit. ALP Vintage C. Last Manufactured: Replacement Parts List No Revision W 10/2017

McQuay. Reciprocating Condensing Unit. ALP Vintage C. Last Manufactured: Replacement Parts List No Revision W 10/2017 Replacement Parts List No. 700015000 Revision W 10/2017 McQuay Reciprocating Condensing Unit ALP 013-230 Vintage C Last Manufactured: 2002 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay Climate Control. Horizontal Water Source Heat Pump. CC, CG, CW Vintage C, D. Last Manufactured: 1986

McQuay Climate Control. Horizontal Water Source Heat Pump. CC, CG, CW Vintage C, D. Last Manufactured: 1986 Replacement Parts List No. 05520400 Revision D 01/2017 McQuay Climate Control Horizontal Water Source Heat Pump CC, CG, CW 0750-1000 Vintage C, D Last Manufactured: 1986 To find your Daikin Applied parts

More information

McQuay. Global Air-Cooled Scroll Chiller. AGZ Vintage A Two-circuit. Last Manufactured: 2005

McQuay. Global Air-Cooled Scroll Chiller. AGZ Vintage A Two-circuit. Last Manufactured: 2005 Replacement Parts List No. 057117900 Revision R 10/2016 McQuay Global Air-Cooled Scroll Chiller AGZ 030-065 Vintage A Two-circuit Last Manufactured: 2005 To find your Daikin Applied parts distributor,

More information

McQuay. Incremental. PFEC, PFES, PFHC, PFHS Suite II, 2 Motor 007, 009, 012, 015 Designs A(1), B(2) Last Manufactured: 2001

McQuay. Incremental. PFEC, PFES, PFHC, PFHS Suite II, 2 Motor 007, 009, 012, 015 Designs A(1), B(2) Last Manufactured: 2001 Replacement Parts List 110505300 Revision G 07/2016 McQuay Incremental PFEC, PFES, PFHC, PFHS Suite II, 2 Motor 007, 009, 012, 015 Designs A(1), B(2) Last Manufactured: 2001 To find your Daikin Applied

More information

Daikin McQuay. Self-Contained Variable and Constant Air Volume. SWP Vintage H. Replacement Parts List No Revision I 11/2017

Daikin McQuay. Self-Contained Variable and Constant Air Volume. SWP Vintage H. Replacement Parts List No Revision I 11/2017 Replacement Parts List No. 7000900 Revision I /207 Daikin McQuay Self-Contained Variable and Constant Air Volume SWP 02-30 Vintage H To find your Daikin Applied parts distributor, call -800-377-2787 or

More information

McQuay Climate Control. Commercial Unitary Rooftop. CUR Vintage F. Last Manufactured: 1996

McQuay Climate Control. Commercial Unitary Rooftop. CUR Vintage F. Last Manufactured: 1996 Replacement s List No. 055236800 Revision C 11/2016 McQuay Climate Control Commercial Unitary Rooftop CUR 075-150 Vintage F Last Manufactured: 1996 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Self-Contained Variable and Constant Air Volume. SWP Vintage F. Replacement Parts List No Revision G 04/2018

McQuay. Self-Contained Variable and Constant Air Volume. SWP Vintage F. Replacement Parts List No Revision G 04/2018 Replacement Parts List No. 700006000 Revision G 04/208 McQuay Self-Contained Variable and Constant Air Volume SWP 08-095 Vintage F To find your Daikin Applied parts distributor, call -800-377-2787 or visit

More information

McQuay. Seasonpak Reciprocating Chiller. WHR Vintage C. Last Manufactured: Replacement Parts List No Revision I 05/2016

McQuay. Seasonpak Reciprocating Chiller. WHR Vintage C. Last Manufactured: Replacement Parts List No Revision I 05/2016 Replacement Parts List No. 055224300 Revision I 05/2016 McQuay Seasonpak Reciprocating Chiller WHR 008-120 Vintage C Last Manufactured: 1998 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 048, 060, 070 Design 1. Replacement Parts List No Revision C 10/2016

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 048, 060, 070 Design 1. Replacement Parts List No Revision C 10/2016 Replacement Parts List No. 700011400 Revision C 10/2016 McQuay Ceiling Mounted Water Source Heat Pump WCRH, WCRW 048, 060, 070 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 030, 036, 042 Design 1. Replacement Parts List No Revision B 10/2016

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 030, 036, 042 Design 1. Replacement Parts List No Revision B 10/2016 Replacement Parts List No. 700011300 Revision B 10/2016 McQuay Ceiling Mounted Water Source Heat Pump WCRH, WCRW 030, 036, 042 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Air Cooled Screw Chiller. ALS Vintage B. Last Manufactured: Replacement Parts List No Revision C 06/2017

McQuay. Air Cooled Screw Chiller. ALS Vintage B. Last Manufactured: Replacement Parts List No Revision C 06/2017 Replacement Parts List No. 700027300 Revision C 06/2017 cquay Air Cooled Screw Chiller ALS 300-425 Vintage B Last anufactured: 2001 To find your Daikin Applied parts distributor, call 1-800-377-2787 or

More information

McQuay. Thinline Vertical Fan Coil Floor Mounted. TSF Vintage G. Last Manufactured: 1997

McQuay. Thinline Vertical Fan Coil Floor Mounted. TSF Vintage G. Last Manufactured: 1997 Replacement Parts List No. 057117400 Revision F 08/2016 McQuay Thinline Vertical Fan Coil Floor Mounted TSF 021-121 Vintage G Last Manufactured: 1997 To find your Daikin Applied parts distributor, call

More information

McQuay. HiLine Fan Coil. HSB Vintage B. Last Manufactured: Replacement Parts List No Revision C 09/2016

McQuay. HiLine Fan Coil. HSB Vintage B. Last Manufactured: Replacement Parts List No Revision C 09/2016 Replacement Parts List No. 055211200 Revision C 09/2016 McQuay HiLine Fan Coil HSB 030-120 Vintage B Last Manufactured: 1990 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit

More information

Daikin McQuay. Incremental. Suite II, 2 Motor PDES Design C (3) Last Manufactured: 2008

Daikin McQuay. Incremental. Suite II, 2 Motor PDES Design C (3) Last Manufactured: 2008 Replacement Parts List 700018500 Revision B 02/2012 Daikin McQuay Incremental Suite II, 2 Motor PDES 009-015 Design C (3) Last Manufactured: 2008 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. Roofpak Applied Rooftop Air Handler. RDS Size 708 Vintage B. Replacement Parts List No Revision F 03/2018

Daikin McQuay. Roofpak Applied Rooftop Air Handler. RDS Size 708 Vintage B. Replacement Parts List No Revision F 03/2018 Replacement Parts List No. 047652600 Revision F 03/208 Daikin McQuay Roofpak Applied Rooftop Air Handler RDS Size 708 Vintage B To find your Daikin Applied parts distributor, call -800-377-2787 or visit

More information

Daikin McQuay. Air- Cooled Condenser. ACH, ACX, ACL Vintage A. Replacement Parts List No Revision C 10/2016

Daikin McQuay. Air- Cooled Condenser. ACH, ACX, ACL Vintage A. Replacement Parts List No Revision C 10/2016 Replacement Parts List No. 700023300 Revision C 0/206 Daikin McQuay Air- Cooled Condenser ACH, ACX, ACL 04-225 Vintage A To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com

More information

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 007, 009, 012 Design 4. Replacement Parts List No Revision L 02/2018

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 007, 009, 012 Design 4. Replacement Parts List No Revision L 02/2018 Replacement Parts List No. 700016100 Revision L 02/2018 Daikin McQuay Enfinity Horizontal Water Source Heat Pump WCCH, WCCW 007, 009, 012 Design 4 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin. PreciseLine Horizontal Large Capacity Blower Coil. BCHD Design 1. Replacement Parts List No Revision A 03/2019

Daikin. PreciseLine Horizontal Large Capacity Blower Coil. BCHD Design 1. Replacement Parts List No Revision A 03/2019 Replacement Parts List No. 700053700 Revision A 03/2019 Daikin PreciseLine Horizontal Large Capacity Blower Coil BCHD 030-050 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. Global Scroll Compressor Air-Cooled Chiller. AGZ Vintage D Unit Revision 00, 0A (Code 55)

Daikin McQuay. Global Scroll Compressor Air-Cooled Chiller. AGZ Vintage D Unit Revision 00, 0A (Code 55) Replacement Parts List No. 70008600 Revision M /207 Daikin McQuay Global Scroll Compressor Air-Cooled Chiller AGZ 025-90 Vintage D Unit Revision 00, 0A (Code 55) To find your Daikin Applied parts distributor,

More information

Daikin McQuay. Maverick II Commercial Packaged Rooftop Cooling and Heating. MPS Vintage E

Daikin McQuay. Maverick II Commercial Packaged Rooftop Cooling and Heating. MPS Vintage E Replacement Parts List No. 70005800 Revision T /07 Daikin McQuay Maverick II Commercial Packaged Rooftop Cooling and Heating MPS 06-075 Vintage E To find your Daikin Applied parts distributor, call -800-377-787

More information

McQuay. Air Cooled Screw Chiller. ALS Vintage B. Last Manufactured: Replacement Parts List No Revision B 05/2016

McQuay. Air Cooled Screw Chiller. ALS Vintage B. Last Manufactured: Replacement Parts List No Revision B 05/2016 Replacement Parts List No. 700027200 Revision B 05/2016 cquay Air Cooled Screw Chiller ALS 220-280 Vintage B Last anufactured: 2001 To find your Daikin Applied parts distributor, call 1-800-377-2787 or

More information

Daikin McQuay. Large Capacity Fan Coil Belt Drive. HCBB, HHBB Design 1. Replacement Parts List No Revision E 03/2018

Daikin McQuay. Large Capacity Fan Coil Belt Drive. HCBB, HHBB Design 1. Replacement Parts List No Revision E 03/2018 Replacement s List No. 700024000 Revision E 03/2018 Daikin McQuay Large Capacity Fan Coil Belt Drive HCBB, HHBB 08-30 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit

More information

McQuay Climate Control Singer

McQuay Climate Control Singer Replacement Parts List No. 55205400 Rev. B 09/2015 McQuay Climate Control Singer Large Vertical Water Source Heat Pump LGP, LHP, LWP 18, 22 Vintage A Last Manufactured: 1989 To find your Daikin Applied

More information

McQuay. Console Water Source Heat Pump. European Unit WWME, WWMJ, WWMK, WWML Designs A, B (1, 2) Last Manufactured: 2004

McQuay. Console Water Source Heat Pump. European Unit WWME, WWMJ, WWMK, WWML Designs A, B (1, 2) Last Manufactured: 2004 Replacement Parts List 110502500 Revision C 02/2017 McQuay Console Water Source Heat Pump European Unit WWME, WWMJ, WWMK, WWML 007-015 Designs A, B (1, 2) Last Manufactured: 2004 To find your Daikin Applied

More information

McQuay. Ceiling Concealed Water Source Heat Pump. CCH, CCG, CCW 015, 019 Vintage A. Last Manufactured: 1995

McQuay. Ceiling Concealed Water Source Heat Pump. CCH, CCG, CCW 015, 019 Vintage A. Last Manufactured: 1995 Replacement Parts List No. 55235700 Revision C 08/2017 McQuay Ceiling Concealed Water Source Heat Pump CCH, CCG, CCW 015, 019 Vintage A Last Manufactured: 1995 To find your Daikin Applied parts distributor,

More information

McQuay Package System MPS062E, MPS070E, MPS075E PL

McQuay Package System MPS062E, MPS070E, MPS075E PL McQuay Package System 062E, 070E, 075E PL-1003-8 062E / 070E / 075E 1 062E / 070E / 075E 2 062E / 070E / 075E 3 062E / 070E / 075E 4 062E / 070E / 075E 5 062E / 070E / 075E 6 062E / 070E / 075E 7 8 Section

More information

McQuay. Water Source Heat Pump. HPH, HPV Vintage A, B. Last Manufactured: Replacement Parts List No Revision B 05/2012

McQuay. Water Source Heat Pump. HPH, HPV Vintage A, B. Last Manufactured: Replacement Parts List No Revision B 05/2012 Replacement Parts List No. 055211500 Revision B 05/2012 McQuay Water Source Heat Pump HPH, HPV 009-059 Vintage A, B Last Manufactured: 1986 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision B 03/2016

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision B 03/2016 Replacement s List 70002400 Revision B 03/206 Daikin McQuay Large Capacity Fan Coil Direct Drive HCDB, HHDB 06-20 Design To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com

More information

McQuay. Enfinity Horizontal Water Source Heat Pump. WCRH, WCRW 007, 009, 012 Design 1. Replacement Parts List No Revision B 02/2018

McQuay. Enfinity Horizontal Water Source Heat Pump. WCRH, WCRW 007, 009, 012 Design 1. Replacement Parts List No Revision B 02/2018 Replacement Parts List No. 700011100 Revision B 02/2018 McQuay Enfinity Horizontal Water Source Heat Pump WCRH, WCRW 007, 009, 012 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Water Source Heat Pump Replacement Chassis. VF Vintage H. Last Manufactured: 1992

McQuay. Water Source Heat Pump Replacement Chassis. VF Vintage H. Last Manufactured: 1992 Replacement Parts List No. 110502800 Revision A 02/2006 McQuay Water Source Heat Pump Replacement Chassis VF 100-330 Vintage H Last Manufactured: 1992 To find your Daikin Applied parts distributor, call

More information

Daikin. Rebel Commercial Packaged Rooftop Cooling & Heating. DPS Vintage A. Replacement Parts List No Revision T 09/2018

Daikin. Rebel Commercial Packaged Rooftop Cooling & Heating. DPS Vintage A. Replacement Parts List No Revision T 09/2018 Replacement Parts List No. 70005400 Revision T 09/208 Daikin Rebel Commercial Packaged Rooftop Cooling & Heating DPS 06-028 Vintage A To find your Daikin Applied parts distributor, call -800-377-2787 or

More information

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage D. LML, LSB, MMM, MSB Vintage E

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage D. LML, LSB, MMM, MSB Vintage E Replacement Parts List No. 046902100 Revision D 01/2015 McQuay Central Station Air Handler LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL 137-172 Vintage D LML, LSB, MMM, MSB 137-172 Vintage E Last Manufactured:

More information

McQuay. Central Station Air Handlers Low Pressure. LHD, LYF, LSL, LML, LWL Vintage C. LML, LSB Vintage E. Last Manufactured: 1999

McQuay. Central Station Air Handlers Low Pressure. LHD, LYF, LSL, LML, LWL Vintage C. LML, LSB Vintage E. Last Manufactured: 1999 Replacement Parts List No. 055222600 Revision F 11/2011 McQuay Central Station Air Handlers Low Pressure LHD, LYF, LSL, LML, LWL 103-228 Vintage C LML, LSB 106-111 Vintage E Last Manufactured: 1999 To

More information

Daikin McQuay. EnerSaver Packaged Terminal Air Conditioner/Heat Pump. PNES; PNHS Design C (3)

Daikin McQuay. EnerSaver Packaged Terminal Air Conditioner/Heat Pump. PNES; PNHS Design C (3) Replacement Parts List No. 700018700 Revision E 04/2015 Daikin McQuay EnerSaver Packaged Terminal Air Conditioner/Heat Pump PNES; PNHS 009-015 Design C (3) To find your Daikin Applied parts distributor,

More information

McQuay. Enfinity Ceiling Mounted Water Source Heat Pump. WCCH, WCCW 019, 024 Design 1. Last Manufactured: 2008

McQuay. Enfinity Ceiling Mounted Water Source Heat Pump. WCCH, WCCW 019, 024 Design 1. Last Manufactured: 2008 Replacement Parts List No. 700013300 Revision A 05/2017 McQuay Enfinity Ceiling Mounted Water Source Heat Pump WCCH, WCCW 019, 024 Design 1 Last Manufactured: 2008 To find your Daikin Applied parts distributor,

More information

McQuay. Seasonmaker Horizontal Fan Coil. TSC Vintage G. Last Manufactured: Replacement Parts List No Revision C 08/2016

McQuay. Seasonmaker Horizontal Fan Coil. TSC Vintage G. Last Manufactured: Replacement Parts List No Revision C 08/2016 Replacement Parts List 057117500 Revision C 08/2016 McQuay Seasonmaker Horizontal Fan Coil TSC 021-121 Vintage G Last Manufactured: 1997 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Cabinet Unit Heater. CHB, CHF Vintage A. FCHB, FCHF Design A (1) Last Manufactured: 2010

McQuay. Cabinet Unit Heater. CHB, CHF Vintage A. FCHB, FCHF Design A (1) Last Manufactured: 2010 Replacement Parts List No. 055211700 Revision G 05/2017 McQuay Cabinet Unit Heater CHB, CHF 003-015 Vintage A FCHB, FCHF 03-15 Design A (1) Last Manufactured: 2010 To find your Daikin Applied parts distributor,

More information

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage C. Last Manufactured: 1984

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage C. Last Manufactured: 1984 Replacement Parts List No. 055222700 Revision D 0/205 McQuay Central Station Air Handler LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL 37-72 Vintage C Last Manufactured: 984 To find your Daikin Applied parts

More information

Roofpak Applied Rooftop Units

Roofpak Applied Rooftop Units Replacement Parts List No. 70005000 Revision P 08/2 Roofpak Applied Rooftop Units RPS, RFS, RCS Sizes: 05-042 Vintage D R40a To find your Daikin McQuay parts distributor, call -800-377-2787 or visit www.daikinmcquay.com

More information

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision C 03/2018

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision C 03/2018 Replacement s List 700024100 Revision C 03/2018 Daikin McQuay Large Capacity Fan Coil Direct Drive HCDB, HHDB 06-20 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit

More information

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 042, 048, 060, 070 Design 5

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 042, 048, 060, 070 Design 5 Replacement Parts List No. 700027900 Revision M 09/2018 Daikin McQuay Enfinity Horizontal Water Source Heat Pump WCCH, WCCW 042, 048, 060, 070 Design 5 To find your Daikin Applied parts distributor, call

More information

McQuay. Incremental. MEK, MHK Vintage A. PKES, PKHS, PRKC, PRKH Design A (1) Replacement Parts List No Revision G 07/2017

McQuay. Incremental. MEK, MHK Vintage A. PKES, PKHS, PRKC, PRKH Design A (1) Replacement Parts List No Revision G 07/2017 Replacement Parts List No. 057110000 Revision G 07/2017 McQuay Incremental MEK, MHK 019-022 Vintage A PKES, PKHS, PRKC, PRKH 019-022 Design A (1) To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. Roofpak Applied Rooftop Units Standard & Digital Scroll Compressor Models. RPS, RFS, RCS Vintage D Code 44= R, D

Daikin McQuay. Roofpak Applied Rooftop Units Standard & Digital Scroll Compressor Models. RPS, RFS, RCS Vintage D Code 44= R, D Replacement Parts List No. 70005000 Revision AN 05/08 Daikin McQuay Roofpak Applied Rooftop Units Standard & Digital Scroll Compressor Models RPS, RFS, RCS 05-04 Vintage D Code 44= R, D To find your Daikin

More information

Daikin. Rebel Commercial Air Handler. DAH A03 - A11 Vintage A. Replacement Parts List No Revision D 06/2018

Daikin. Rebel Commercial Air Handler. DAH A03 - A11 Vintage A. Replacement Parts List No Revision D 06/2018 Replacement Parts List No. 700052500 Revision D 06/208 Daikin Rebel Commercial Air Handler DAH A03 - A Vintage A To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com

More information

McQuay Central Station Air Handler Medium Pressure MSL

McQuay Central Station Air Handler Medium Pressure MSL Replacement Parts List No. 55223700 Revision B 09/2016 McQuay Central Station Air Handler Medium Pressure MSL 190 Vintage C Last Manufactured: 1998 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin Daikin McQuay. Rebel Commercial Packaged Rooftop Cooling and Heating. DPS Vintage A

Daikin Daikin McQuay. Rebel Commercial Packaged Rooftop Cooling and Heating. DPS Vintage A Replacement Parts List No. 700024200 Revision AE 0/209 Daikin Daikin McQuay Rebel Commercial Packaged Rooftop Cooling and Heating DPS 005-006 Vintage A To find your Daikin Applied parts distributor, call

More information

SUBMITTAL DATA. for. MWSU-Popplewell Hall 1st Floor

SUBMITTAL DATA. for. MWSU-Popplewell Hall 1st Floor SUBMITTAL DATA for Prepared by Kevyn Gordon 4/27/2017 Job Name: 1 of 35 www.daikinapplied.com Table of Contents Technical Data Sheet for AHU-1st Floor... 3 Fan Curve for AHU-1st Floor... 7 Drawing for

More information

Daikin McQuay. Roofpak Applied Rooftop Units Standard Compressor Models. RPS, RFS, RDT, RCS Tons Vintage D Unit Model Code 44= R, S

Daikin McQuay. Roofpak Applied Rooftop Units Standard Compressor Models. RPS, RFS, RDT, RCS Tons Vintage D Unit Model Code 44= R, S Replacement Parts List No. 70000800 Revision AR 05/08 Daikin McQuay Roofpak Applied Rooftop Units Standard Compressor Models RPS, RFS, RDT, RCS 080-40 Tons Vintage D Unit Model Code 44= R, S To find your

More information

Daikin McQuay. Roofpak Applied Rooftop Units Standard & Digital Scroll Compressor Models

Daikin McQuay. Roofpak Applied Rooftop Units Standard & Digital Scroll Compressor Models Replacement Parts List No. 70003700 Revision AR 05/08 Daikin McQuay Roofpak Applied Rooftop Units Standard & Digital Scroll Compressor Models RPS, RDT, RFS, RCS 045-079 Tons Vintage D Unit Model Code 44=

More information

Daikin. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW Design 2. Replacement Parts List No Revision F 04/2018

Daikin. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW Design 2. Replacement Parts List No Revision F 04/2018 Replacement Parts List No. 700050900 Revision F 04/2018 Daikin Enfinity Horizontal Water Source Heat Pump WCCH, WCCW 072-120 Design 2 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay Air Cooled Chiller AWS280A, AWS300A, AWS320A, AWS350A PL

McQuay Air Cooled Chiller AWS280A, AWS300A, AWS320A, AWS350A PL McQuay Air Cooled Chiller 280A, 300A, 320A, 350A PL-1008-7 280A / 300A / 320A / 350A 1 280A / 300A / 320A / 350A 2 280A / 300A / 320A / 350A 3 280A / 300A / 320A / 350A 4 280A / 300A / 320A / 350A 5 280A

More information

Daikin Daikin McQuay. Rebel Commercial Packaged Rooftop Cooling and Heating. DPS Vintage A

Daikin Daikin McQuay. Rebel Commercial Packaged Rooftop Cooling and Heating. DPS Vintage A Replacement Parts List No. 700024300 Revision AA 08/208 Daikin Daikin McQuay Rebel Commercial Packaged Rooftop Cooling and Heating DPS 003-004 Vintage A To find your Daikin Applied parts distributor, call

More information

Daikin McQuay. Enfinity Vertical Water Source Heat Pump. WVFC, WVFW Design 1. Replacement Parts List No Revision S 01/2018

Daikin McQuay. Enfinity Vertical Water Source Heat Pump. WVFC, WVFW Design 1. Replacement Parts List No Revision S 01/2018 Replacement Parts List No. 700012100 Revision S 01/2018 Daikin McQuay Enfinity Vertical Water Source Heat Pump WVFC, WVFW 009-070 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay Climate Control Singer. Rooftop Unit. ER, R 080 Vintage A, B, C, D. Last Manufactured: 1996

McQuay Climate Control Singer. Rooftop Unit. ER, R 080 Vintage A, B, C, D. Last Manufactured: 1996 Replacement Parts List No. 779200300 Revision C 04/2011 McQuay Climate Control Singer Rooftop Unit ER, R 080 Vintage A, B, C, D Last Manufactured: 1996 To find your Daikin Applied parts distributor, call

More information

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW Design 1. Replacement Parts List No Revision I 12/2015

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW Design 1. Replacement Parts List No Revision I 12/2015 Replacement Parts List No. 700014800 Revision I 12/2015 Daikin McQuay Vertical Stack Water Source Heat Pump WVHC, WVHF, WVHW 009-036 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin. TrailBlazer Air-Cooled Scroll Chiller. AMZ Vintage A. Replacement Parts List No Revision C 01/2018

Daikin. TrailBlazer Air-Cooled Scroll Chiller. AMZ Vintage A. Replacement Parts List No Revision C 01/2018 Replacement Parts List No. 700052900 Revision C 0/208 Daikin TrailBlazer Air-Cooled Scroll Chiller AMZ 00-040 Vintage A To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com

More information

McQuay. Thermal Systems Absorption Chiller ME, MF Vintage A. Last Manufactured: Replacement Parts List No New 05/2001

McQuay. Thermal Systems Absorption Chiller ME, MF Vintage A. Last Manufactured: Replacement Parts List No New 05/2001 Replacement Parts List No. 1105050 New 05/2001 McQuay Thermal Systems Absorption Chiller ME, MF 21-33 Vintage A Last Manufactured: 1997 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin. Roofpak Applied Rooftop Units Inverter Compressor Models. RPS Vintage D Code 44= V, W

Daikin. Roofpak Applied Rooftop Units Inverter Compressor Models. RPS Vintage D Code 44= V, W Replacement Parts List No. 70005200 Revision J 05/208 Daikin Roofpak Applied Rooftop Units Inverter Compressor Models RPS 06-042 Vintage D Code 44= V, W To find your Daikin Applied parts distributor, call

More information

Daikin McQuay. VAV Air Terminal Unit MQ FCI6, FVI5, THI5. Replacement Parts List No Revision J 07/2017

Daikin McQuay. VAV Air Terminal Unit MQ FCI6, FVI5, THI5. Replacement Parts List No Revision J 07/2017 Replacement Parts List No. 700020000 Revision J 07/2017 Daikin McQuay VAV Air Terminal Unit MQ FCI6, FVI5, THI5 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.daikinapplied.com

More information

McQuay Climate Control Singer. Rooftop Unit. ER, R 250 Vintage C, D. Last Manufactured: Replacement Parts List No Revision C 04/2002

McQuay Climate Control Singer. Rooftop Unit. ER, R 250 Vintage C, D. Last Manufactured: Replacement Parts List No Revision C 04/2002 Replacement Parts List No. 779200800 Revision C 04/2002 McQuay Climate Control Singer Rooftop Unit ER, R 250 Vintage C, D Last Manufactured: 1996 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Water-Cooled Screw Chiller. PFS Vintage B. Last Manufactured: Replacement Parts List No Revision D 02/2017

McQuay. Water-Cooled Screw Chiller. PFS Vintage B. Last Manufactured: Replacement Parts List No Revision D 02/2017 Replacement Parts List No. 057118200 Revision D 02/2017 McQuay Water-Cooled Screw Chiller PFS 150-215 Vintage B Last Manufactured: 1997 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Seasonmaker Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage A. Last Manufactured: 1986

McQuay. Seasonmaker Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage A. Last Manufactured: 1986 Replacement Parts List No. 47650300 Rev. A 09/205 McQuay Seasonmaker Large Capacity Fan Coil Direct Drive SCD, SHD 06-20 Vintage A Last Manufactured: 986 To find your Daikin Applied parts distributor,

More information

Daikin. Trailblazer Air-Cooled Scroll Chiller. AGZ Vintage E Unit Revision 00. Replacement Parts List No Revision C 11/2015

Daikin. Trailblazer Air-Cooled Scroll Chiller. AGZ Vintage E Unit Revision 00. Replacement Parts List No Revision C 11/2015 Replacement Parts List No. 700050800 Revision C /205 Daikin Trailblazer Air-Cooled Scroll Chiller AGZ 075-80 Vintage E Unit Revision 00 To find your Daikin Applied parts distributor, call -800-377-2787

More information

Westinghouse. Rooftop Heating and Cooling. IK 180 Vintage 0, 1, 2, 3, 4. Last Manufactured: 1975

Westinghouse. Rooftop Heating and Cooling. IK 180 Vintage 0, 1, 2, 3, 4. Last Manufactured: 1975 Replacement Parts List No. 055227700 Revision A 03/2003 Westinghouse Rooftop Heating and Cooling IK 180 Vintage 0, 1, 2, 3, 4 Last Manufactured: 1975 To find your Daikin Applied parts distributor, call

More information

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW 036 Design 2. Replacement Parts List No Revision A 12/2015

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW 036 Design 2. Replacement Parts List No Revision A 12/2015 Replacement Parts List No. 700050700 Revision A 12/2015 Daikin McQuay Vertical Stack Water Source Heat Pump WVHC, WVHF, WVHW 036 Design 2 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1 Replacement Parts List No. 700024700 Revision M 11/2017 Daikin Daikin McQuay SmartSource Single Stage Horizontal Water Source Heat Pump WGSH 007, 009, 012 Design 1 To find your Daikin Applied parts distributor,

More information

McQuay. Two-Stage Centrifugal Chiller WTC 700. Replacement Parts List No Revision B 07/2017

McQuay. Two-Stage Centrifugal Chiller WTC 700. Replacement Parts List No Revision B 07/2017 Replacement Parts List No. 700014000 Revision B 07/2017 McQuay Two-Stage Centrifugal Chiller WTC 700 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.daikinapplied.com Table

More information

McQuay. Magnitude Magnetic Bearing Centrifugal Chiller WMC 035T. Last Manufactured: Replacement Parts List No Revision J 12/2017

McQuay. Magnitude Magnetic Bearing Centrifugal Chiller WMC 035T. Last Manufactured: Replacement Parts List No Revision J 12/2017 Replacement Parts List No. 700005800 Revision J 12/2017 McQuay Magnitude Magnetic Bearing Centrifugal Chiller WMC 035T Last Manufactured: 2008 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Magnitude Water-Cooled Magnetic Bearing Centrifugal Chiller. WMC 150 Vintage A. Last Manufactured: 2005

McQuay. Magnitude Water-Cooled Magnetic Bearing Centrifugal Chiller. WMC 150 Vintage A. Last Manufactured: 2005 Replacement Parts List No. 700005500 Revision J 10/2017 McQuay Magnitude Water-Cooled Magnetic Bearing Centrifugal Chiller WMC 150 Vintage A Last Manufactured: 2005 To find your Daikin Applied parts distributor,

More information

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1 Replacement Parts List No. 700024700 Revision O 10/2018 Daikin Daikin McQuay SmartSource Single Stage Horizontal Water Source Heat Pump WGSH 007, 009, 012 Design 1 To find your Daikin Applied parts distributor,

More information

McQuay. Two-Stage Centrifugal Chiller WTC 500. Replacement Parts List No Revision A 10/2011

McQuay. Two-Stage Centrifugal Chiller WTC 500. Replacement Parts List No Revision A 10/2011 Replacement Parts List No. 700019800 Revision A 10/2011 McQuay Two-Stage Centrifugal Chiller WTC 500 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.daikinapplied.com Table

More information

Westinghouse. Rooftop Heating and Cooling. IK 300 Vintage 0, 1, 2, 3, 4, 5. Last Manufactured: 1975

Westinghouse. Rooftop Heating and Cooling. IK 300 Vintage 0, 1, 2, 3, 4, 5. Last Manufactured: 1975 Replacement Parts List No. 055227900 Revision A 03/2003 Westinghouse Rooftop Heating and Cooling IK 300 Vintage 0,, 2, 3, 4, 5 Last Manufactured: 975 To find your Daikin Applied parts distributor, call

More information

Daikin Daikin McQuay. Rebel Commercial Packaged Rooftop Cooling and Heating. DPS Vintage A

Daikin Daikin McQuay. Rebel Commercial Packaged Rooftop Cooling and Heating. DPS Vintage A Replacement Parts List No. 700023600 Revision AK 07/208 Daikin Daikin McQuay Rebel Commercial Packaged Rooftop Cooling and Heating DPS 007-02 Vintage A To find your Daikin Applied parts distributor, call

More information

McQuay. Roofpak Applied Rooftop Units. RPS/RFS/RCS Vintage C. Replacement Parts List No Revision BD 04/2018

McQuay. Roofpak Applied Rooftop Units. RPS/RFS/RCS Vintage C. Replacement Parts List No Revision BD 04/2018 Replacement Parts List No. 0577700 Revision BD 04/08 McQuay Roofpak Applied Rooftop Units RPS/RFS/RCS 05-040 Vintage C To find your Daikin Applied parts distributor, call -800-377-787 or visit www.daikinapplied.com

More information

McQuay. Large Capacity Fan Coil Belt Drive. SCB, SHB Vintage B. FCZA, FCZC, FCZH, FHZA, FHZC, FHZH S08 - S30 Design A (1)

McQuay. Large Capacity Fan Coil Belt Drive. SCB, SHB Vintage B. FCZA, FCZC, FCZH, FHZA, FHZC, FHZH S08 - S30 Design A (1) Replacement Parts List No. 055236400 Revision U 0/208 McQuay Large Capacity Fan Coil Belt Drive SCB, SHB 08-30 Vintage B FCZA, FCZC, FCZH, FHZA, FHZC, FHZH S08 - S30 Design A () To find your Daikin Applied

More information

McQuay Air Cooled Chiller AWS175A, AWS190A, AWS210A, AWS230A, AWS250A AWS280A, AWS300A, AWS320A, AWS350A, AWS380A, AWS405A PL

McQuay Air Cooled Chiller AWS175A, AWS190A, AWS210A, AWS230A, AWS250A AWS280A, AWS300A, AWS320A, AWS350A, AWS380A, AWS405A PL McQuay Air Cooled Chiller AWS175A, AWS190A, AWS210A, AWS230A, AWS250A AWS280A, AWS300A, AWS320A, AWS350A, AWS380A, AWS405A PL-1007-3 AWS175A / AWS190A / AWS210A / AWS230A / AWS250A / AWS280A / AWS300A

More information

McQuay. Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage B. FSCD, FSHD Design A (1)

McQuay. Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage B. FSCD, FSHD Design A (1) Replacement Parts List No. 055236500 Revision J 07/207 McQuay Large Capacity Fan Coil Direct Drive SCD, SHD 06-20 Vintage B FSCD, FSHD 06-20 Design A () To find your Daikin Applied parts distributor, call

More information

ComfortPac 42 x 16. PTAC, PTHP Sizes Vintages B and B+ (2) Replacement Parts List No Rev. P 1/2012

ComfortPac 42 x 16. PTAC, PTHP Sizes Vintages B and B+ (2) Replacement Parts List No Rev. P 1/2012 Replacement Parts List No. 110511900 Rev. P 1/2012 ComfortPac 42 x 16 PTAC, PTHP Sizes 07-15 Vintages B and B+ (2) To find your McQuay parts distributor, call 1-800-377-2787 or visit www.mcquay.com Table

More information

Daikin. Magnitude Magnetic Bearing Compressor Centrifugal Chiller. WMC 400D Vintage C. Replacement Parts List No Revision B 10/2015

Daikin. Magnitude Magnetic Bearing Compressor Centrifugal Chiller. WMC 400D Vintage C. Replacement Parts List No Revision B 10/2015 Replacement Parts List No. 700029500 Revision B 10/2015 Daikin Magnitude Magnetic Bearing Compressor Centrifugal Chiller WMC 400D Vintage C To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Seasonmaker Fan Coil. TSF, TSB, TSC Vintage C. Last Manufactured: Replacement Parts List No Revision D 09/2016

McQuay. Seasonmaker Fan Coil. TSF, TSB, TSC Vintage C. Last Manufactured: Replacement Parts List No Revision D 09/2016 Replacement Parts List No. 055211000 Revision D 09/2016 McQuay Seasonmaker Fan Coil TSF, TSB, TSC 021-151 Vintage C Last Manufactured: 1989 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin. SmartSource Compact Vertical Water Source Heat Pump. WGCV 048, 060, 070 Design 1. Replacement Parts List No Revision D 01/2018

Daikin. SmartSource Compact Vertical Water Source Heat Pump. WGCV 048, 060, 070 Design 1. Replacement Parts List No Revision D 01/2018 Replacement Parts List No. 700052400 Revision D 01/2018 Daikin SmartSource Compact Vertical Water Source Heat Pump WGCV 048, 060, 070 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Centrifugal Chiller WPV 320A - 350A. Last Manufactured: Replacement Parts List No Revision E 12/2017

McQuay. Centrifugal Chiller WPV 320A - 350A. Last Manufactured: Replacement Parts List No Revision E 12/2017 Replacement Parts List No. 700005300 Revision E 12/2017 McQuay Centrifugal Chiller WPV 320A - 350A Last Manufactured: 2008 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.daikinapplied.com

More information

McQuay Climate Control Singer. Rooftop Unit. ER, R 160 Vintage A, B, C, D. Last Manufactured: 1996

McQuay Climate Control Singer. Rooftop Unit. ER, R 160 Vintage A, B, C, D. Last Manufactured: 1996 Replacement Parts List No. 779200600 Revision B 07/2007 McQuay Climate Control Singer Rooftop Unit ER, R 160 Vintage A, B, C, D Last Manufactured: 1996 To find your Daikin Applied parts distributor, call

More information

McQuay. Roofpak Applied Rooftop Units. RPS, RCS, RFS Vintage B. RBS, RDS, RHS, RWS Vintage B

McQuay. Roofpak Applied Rooftop Units. RPS, RCS, RFS Vintage B. RBS, RDS, RHS, RWS Vintage B Replacement Parts List No. 047654300 Revision AC 06/2016 McQuay Roofpak Applied Rooftop Units RPS, RCS, RFS 018-100 Vintage B RBS, RDS, RHS, RWS 800-808 Vintage B To find your Daikin Applied parts distributor,

More information

Daikin. Rebel Commercial Air Handler VRV DOAS. DVS V05, V10, V12 Vintage A. Replacement Parts List No Revision D 04/2018

Daikin. Rebel Commercial Air Handler VRV DOAS. DVS V05, V10, V12 Vintage A. Replacement Parts List No Revision D 04/2018 Replacement Parts List No. 700052600 Revision D 04/208 Daikin Rebel Commercial Air Handler VRV DOAS DVS V05, V0, V2 Vintage A To find your Daikin Applied parts distributor, call -800-377-2787 or visit

More information

Daikin Daikin McQuay. SmartSource Single Stage Vertical Water Source Heat Pump. WGSV 007, 009, 012 Design 1

Daikin Daikin McQuay. SmartSource Single Stage Vertical Water Source Heat Pump. WGSV 007, 009, 012 Design 1 Replacement Parts List No. 700029600 Revision L 11/2017 Daikin Daikin McQuay SmartSource Single Stage Vertical Water Source Heat Pump WGSV 007, 009, 012 Design 1 To find your Daikin Applied parts distributor,

More information

Daikin McQuay. Enfinity Vertical Water Source Heat Pump. WVFC, WVFW Design 1. Replacement Parts List No Revision V 11/2018

Daikin McQuay. Enfinity Vertical Water Source Heat Pump. WVFC, WVFW Design 1. Replacement Parts List No Revision V 11/2018 Replacement Parts List No. 700012100 Revision V 11/2018 Daikin McQuay Enfinity Vertical Water Source Heat Pump WVFC, WVFW 009-070 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin. Magnitude Magnetic Bearing Compressor Centrifugal Chiller. WMC 350D, 400D Vintage C. Replacement Parts List No Revision F 10/2017

Daikin. Magnitude Magnetic Bearing Compressor Centrifugal Chiller. WMC 350D, 400D Vintage C. Replacement Parts List No Revision F 10/2017 Replacement Parts List No. 700029500 Revision F 10/2017 Daikin Magnitude Magnetic Bearing Compressor Centrifugal Chiller WMC 350D, 400D Vintage C To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Centrifugal Chiller. PF/PFH Size: 063. Replacement Parts List No Revision V 05/2012

Centrifugal Chiller. PF/PFH Size: 063. Replacement Parts List No Revision V 05/2012 Replacement Parts List No. 057113900 Revision V 05/2012 Centrifugal Chiller PF/PFH Size: 063 To find your Daikin McQuay parts distributor, call 1-800-377-2787 or visit www.daikinmcquay.com Contents Parts

More information

Daikin McQuay. Destiny Indoor Air Handler. LAH Vintage A. Replacement Parts List No Revision T 10/2017

Daikin McQuay. Destiny Indoor Air Handler. LAH Vintage A. Replacement Parts List No Revision T 10/2017 Replacement Parts List No. 700004800 Revision T 10/2017 Daikin McQuay Destiny Indoor Air Handler LAH 002-030 Vintage A To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.daikinapplied.com

More information

McQuay. Console Water Source Heat Pump. WMH, WMG, WMK, WCH, WCG 007, 009,012 Vintage B. Last Manufactured: 1998

McQuay. Console Water Source Heat Pump. WMH, WMG, WMK, WCH, WCG 007, 009,012 Vintage B. Last Manufactured: 1998 Replacement Parts List No. 057101600 Revision E 06/2015 McQuay Console Water Source Heat Pump WMH, WMG, WMK, WCH, WCG 007, 009,012 Vintage B Last Manufactured: 1998 To find your Daikin Applied parts distributor,

More information

Daikin. Magnitude TM Magnetic Bearing Centrifugal Chiller. WME 0501S, 0502S, 0701S, 0702S Vintage B

Daikin. Magnitude TM Magnetic Bearing Centrifugal Chiller. WME 0501S, 0502S, 0701S, 0702S Vintage B Replacement Parts List No. 0700053000 Revision C 02/2018 Daikin Magnitude TM Magnetic Bearing Centrifugal Chiller WME 0501S, 0502S, 0701S, 0702S Vintage B To find your Daikin Applied parts distributor,

More information

Centrifugal Chiller PE046, PE047, PE048, PE050 PEH PF083, PF096, PF105, PF116 PH PHH PL

Centrifugal Chiller PE046, PE047, PE048, PE050 PEH PF083, PF096, PF105, PF116 PH PHH PL Centrifugal Chiller PE046, PE047, PE048, PE050 PEH046-050 PF083, PF096, PF105, PF116 PH046-050 PHH046-050 PL-906-49 Unit ASSY. - Labels / 1987 to Present Unit ASSY. - Labels / 1987 to Present No. Index

More information

Daikin. Rebel Commercial Packaged Rooftop Cooling and Heating. DPS 015 Vintage A. Replacement Parts List No Revision W 03/2018

Daikin. Rebel Commercial Packaged Rooftop Cooling and Heating. DPS 015 Vintage A. Replacement Parts List No Revision W 03/2018 Replacement Parts List No. 700027400 Revision W 03/208 Daikin Rebel Commercial Packaged Rooftop Cooling and Heating DPS 05 Vintage A To find your Daikin Applied parts distributor, call -800-377-2787 or

More information

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 015, 019 Design 1

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 015, 019 Design 1 Replacement Parts List No. 700024800 Revision N 10/2018 Daikin Daikin McQuay SmartSource Single Stage Horizontal Water Source Heat Pump WGSH 015, 019 Design 1 To find your Daikin Applied parts distributor,

More information