Daikin McQuay. Roofpak Applied Rooftop Air Handler. RDS Size 708 Vintage B. Replacement Parts List No Revision F 03/2018

Size: px
Start display at page:

Download "Daikin McQuay. Roofpak Applied Rooftop Air Handler. RDS Size 708 Vintage B. Replacement Parts List No Revision F 03/2018"

Transcription

1 Replacement Parts List No Revision F 03/208 Daikin McQuay Roofpak Applied Rooftop Air Handler RDS Size 708 Vintage B To find your Daikin Applied parts distributor, call or visit

2 Contents Parts List Revision History... 4 Unit Model & Serial Number Nomenclature... 5 Unit Model Number- Complete Typical Unit Layout Diagrams...0 Electrical Legend... Section A- Return Air Section Notes % Outside Air Damper with Hood: Code 8= A % Outside Air Damper with Hood: Code 5= K % Hood w/o Damper: Code 5= J % Outside Air Damper Mixing Box with Hood: Code 8= M...5 Return Fan Dampers...6 Return Fan Assemblies 5" x 5" Forward Curved Fan w/o Variable Inlet Vanes...7, 8 5" x 5" Forward Curved Fans w/ Variable Inlet Vanes...9, 20 6" Airfoil Fans w/o Variable Inlet Vanes... 2, 22 6" Airfoil Fans w/ Variable Inlet Vanes Return Air Fan Mounting 5" x 5" Forward Curved Fan " x 5" Forward Curved Fan w/ Seismic Mounting " Airfoil Fan " Airfoil Fan w/ Seismic Mounting Return Air Fan Motors Miscellaneous Electrical Components: LT, S, REC... 3 Section B- Economizer Damper Section Notes Economizer Dampers: Code 8= B Section C- Filter/Final Filter Section Notes Filter Section Assembly Filters 996 & Before... 35, 36 Filters 999 & Later... 37, 38 Section D- Coil Section Notes Contractor Coil Code Strings Drain Pans & Piping Vestibule... 4 Face & Bypass Dampers Section E- Supply Fan Section Notes Supply Fan Dampers Fan Assemblies 5" Forward Curved Fans w/o Inlet Vanes... 45, 46 5" x 5" Forward Curved Fan w/ Inlet Vanes... 47, 48 6" Airfoil Fans w/o Variable Inlet Vanes... 49, 50 6" Airfoil Fans w/ Variable Inlet Vanes Supply Air Fan Mounting Diagrams " Forward Curved Fans- Components... 55, 56 6" Airfoil Fan- Components... 57, 58 Additional Seismic Restraint Components Supply Air Fan Motors Miscellaneous Electrical Components- LT0, S0, REC Section F- Discharge Plenum Section Notes...62 Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 2

3 Contents, Continued Section G- Power Panel/Main Control Box Notes...63 Power Panel Until 3/05 Diagram...64 Common Components...65 Fan Motor Contactors, Overloads & Fusing Components Power Panel 3/05 thru 0/06 Diagrams...70 Common Components...7 Disconnect Switch...72 Supply Fan CB0, & Return Fan CB20 Circuit Breaker...73 Supply MMP0 & M0 Fan Contactor & Return MMP20 & M20 Fan Contactor Power Panel /07 & Later Diagrams...79 Control Box Component Label Diagram...80 Common Components...8 Disconnect Switch...82 Supply Fan CB0, & Return Fan CB20 Circuit Breaker...83, 84 Supply MMP0 & M0 Fan Contactor & Return MMP20 & M20 Fan Contactor Inverters (VFDs)...88 Section H- Miscellaneous Cabinet Components Notes...89 Door Latches...89 Door Hinge...89 Door Holding Rod...89 For units built during the design transition of 0/06 thru 2/06 Contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 3

4 Parts List Revision History Rev. Date Description New 4/89 4/89 is the date of online scanned RPL. Unknown number of previous revisions from 984 original, consider as new. A 8/ Released updated version in current software format. B 2/ Page 30, 60: Corrected voltage code in table from Code "03" to "04". Page 43: Rewrote notes. C 6/2 Cover, Rev. Page: Updated to Daikin McQuay logo format. Various: Changed "McQuay Parts" to "Daikin McQuay". Page 88: P/N is ONLY 5HP 460V. Deleted invalid table information and re-arranged p/n order. Added Footnote #3. D 2/4 Cover, Rev. pg.: Updated to Daikin Applied logo format. Various: Changed McQuay and Daikin McQuay to Daikin Applied. Page 6: Added footnote #. Page 7: Deleted unused Code 4 option "T". Page 8: Updated Code 24. Page 2, 32, 34, 39, 43, 62, 63: Rewrote Notes. Added unit dwg. Page 3, 3: Added dwg. header. Page 7-23, 25, 45-5: Rewrote footnotes. Page 22, 25, 50, 53: Changed Ref # 2 description from "Housing Assy." to "Wheel/Housing Assy." Rewrote footnote #2. Page 33: Changed Ref # 2 p/ns from " " to " ". Page 4, 42: Rewrote Coil Bub. header description. Page 66-69: Removed OL & OL Heater p/ns. Updated footnotes. Page 72: Rewrote footnote and corrected footnote notation. Page 77: Updated dwg. Added in Bub # 3A. Rewrote footnote #2. Page 78: Added Ref. # 3A to table. Deleted N/S footnote references. Page 88: Rewrote footnote #2. Page 89: Reorganized and updated entire page. Rewrote Notes. Updated TOC. E 0/6 Cover: Updated to Daikin Legacy format. Page : Added footnote # & footnote notation. Page 2, 39, 43: Rewrote Notes. Page 4, 5: Rewrote footnote #. F 03/8 Page 2, 43: Rewrote Notes. Page 7, 9, 2, 23, 45, 47, 49, 5: Rewrote footnote #. Page 8, 20, 22, 25, 46, 48, 50, 53: Rewrote note #. Daikin Applied, 3600 Industrial Park Blvd., P.O. Box 55, Minneapolis, MN (763) Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 4

5 Unit Model & Serial Number Nomenclature Unit Model Number R D S 708 B Singlezone Unit Unit Configuration D= Draw Thru Coil Section Roofpak: R= Roofpak Applied Rooftop Design Vintage Unit Size 708= Small Cabinet, 2, CFM Serial Number- Until February, LA Unit Serial Number Serial Number- February, 999 & Later FBO U Factory 3= Faribault, MN Engineering Revision Sequence Year and Month of Manufacture Year A = 97 R = 986 B = 972 S = 987 C = 973 T = 988 D = 974 U = 989 E = 975 V = 990 F = 976 W = 99 G = 977 X = 992 H = 978 Y = 993 J = 979 Z = 994 K= = 995 L = 98 6 = 996 M = = 997 N = = 998 P = = 999 Q = 985 Month A= January B= February C= March D= April E= May F= June G= July H= August J= September K= October L= November M= December Plant Identification FBO = Faribault, MN U= Unit Year of Manufacture 99 = = = = = = = = = = = = 200 etc. Serial Number (build sequence) Month of Manufacture 0= January 02= February 03= March 04= April 05= May 06= June 07= July 08= August 09= September 0= October = November 2= December Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 5

6 Unit Model Number- Complete Unit Model Number- Complete RDS708B Y 27 AL Y YY Y A YYYY Y EA2F Y Y YY000 Y Y ED2F YY Code YYYY YYYY Y YYYYYY EYYY A YYYY Y Y Y 250C 853C YYYY Y Code 03= Blow Thru Blank Section Y= None B= 33" Blank Section After Supply Fan Code 04= Unit Voltage 2= 208/60/3 29= 230/60/3 28= 380/50/3 27= 460/60/3 37= 575/60/3 Code 05= Starting Option AL= Across the Line XX= Special Code 06= Electrical Power Package (In SAF Section) Y= None A= SAF Controls Only E= SAF & RAF Controls B= Purchased Control Box SAF Only w/ GE Components C= Purchased Control Box SAF Only w/ SE Components F= Purchased Control Box SAF & RAF w/ GE Components G= Purchased Control Box SAF & RAF w/ SE Components X= Special Code 07= Insulation and Liners = " ¾lb. Fiberglass Insulation w/ no Liners 2= ½" ½lb. Insulation w/ Sold Liners 3= ½" ½lb. Insulation w/ Sold Liners/Perf. Liner in Plenum X= Special Code 08= Inverter Digit, Inverter Function Y= None 6= Supply Fan (SAF) 7= Supply (SAF) & Return (RAF) Fans Digit 2, Inverter Brand Y= None A= ABB R= Reliance Code 09=Fan Section Options Y= None A= SA Fan Section Light B= RA Fan Section Light C= SA & RA Fan Light X= Special Code 0= Motor Type Y= Standard Efficiency ODP Motor A= 800 RPM ODP Motor E= 800 RPM ODP Hi-Efficiency Motor G= 800 RPM TEFC Motor H= High Efficiency ODP Motor (Before 9/2000) H= 800 RPM TEFC High Efficiency Motor (after 9/2000) J= 800 RPM ODP Premium Efficiency Motor K= 800 RPM TEFC Premium Efficiency Motor X= Special Code = Final Filter Section YYYY= None AAAA= Blank 33" Section located after Heat Section BBBB= Final Filter 33" Section located after Heat Section BYYY= 33" Blank Section FEYY= 33" Final Filter Section w/ 95% Flat Cartridge Filters FYYY= 33" Final Filter Section XXXX= Special Code 2= Belt Guard Y= None A= SA Fan Only B= RA Fan Only C= SA & RA Fans X= Special Code 3= Supply Air (SA) Fan Drive Digit, Motor HP E=.0HP; F=.5HP; G= 2.0HP; H= 3.0HP; J= 5.0HP; K= 7.5HP; L= 0.0HP Digit 2, Fan Size A= 5" x 6" Fan B= 5" x 9" Fan C= 5" x 5" Fan E= 6" Fan Digit 3, Fan RPM (Minimum to Maximum Fan RPM Range) Digit 4= Wheel Type A= Airfoil Wheel, DW F= Forward Curved Wheel V= Airfoil Wheel, DW w/ Inlet Vanes G= Forward Curved Wheel w/ Inlet Vanes Digit 5, Fan Isolation = Rubber In Shear (RIS) 2= Spring 3= Spring w/ Seismic Snubbers An "X" located in any position in a code string indicates a special feature. Contact Daikin Applied with model and serial number information in order to correctly identify the required part(s). The code string shown above represents a typical code string for a unit built 999 & Later. Several codes for units built 999 & Earlier vary from what is shown. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 6

7 Unit Model Number- Complete Continued Code 4= Discharge Air Plenum Y= None G= Bottom H= Front R= Right Side Opening S= Left Side Opening D= Down Discharge X= Special Code 5= Return Air Plenum Y= None G= Bottom H= Back J= 00% Hood w/ no Damper or RA Section K=00% Hood w/ Damper, no RA Section T= Top X= Special Code 6= Miscellaneous Controls/Unit Length Digit - 2, Optional Hardware YY= None YA= Bypass, SA Only YB= Bypass, SA & RA YC= Bypass, RA Only XX= Special Digit 3-5, Unit Length YYY= Not a requirement ***= Unit Length in Inches XXX= Special Code 7= Filters 996 & Before Y= None A= 2" Throwaway B= 2" Cleanable C= Bag Type, 45% w/o Prefilters D= Bag Type, 45% w/ Prefilters E= Bag Type, 95% w/ Prefilters F= A + B w/ No Filters provided G= 2" 35% Pleated Throwaway X= Special Code 7= Filters 999 & Later Y= None A= Angular Rack w/ Throwaway Filters B= Angular Rack w/ Cleanable Filters C= Angular Rack Only G= Angular Rack w/ 30% Filters D= Flat Rack with 65% Cartridge Filters E= Flat with 95% Cartridge Filters F= Flat Rack Only X= Special Code 8= Damper Control 996 & Earlier Y= None A= 0-30% Outdoor air w/ manual operation B= 0-00% Outdoor air w/ manual operation & Economizer M= 0-00% Outdoor/Return Air Mixing Box w/ Dampers X= Special Code 8= Outside Air Options 999 & Later Y= None A= 0-30% Outdoor air B= 0-00% Economizer w/barometric exhaust in a 33" Section M= 0-00% Outdoor Air Mixing Box w/ Hood X= Special Code 9= Return Air (RA) Fan Drive Digit, Motor HP E=.0HP; F=.5HP; G= 2.0HP; H= 3.0HP; J= 5.0HP X= Special Digit 2, Fan Size D= 5" x 5" Fan E= 6" Fan X= Special Digit 3, Fan RPM (Minimum to Maximum Fan RPM Range) Digit 4, Wheel Type A= Airfoil Wheel, DW F= Forward Curved Wheel V= Airfoil Wheel, DW w/ Inlet Vanes G= Forward Curved Wheel w/ Inlet Vanes X= Special Digit 5, Fan Isolation = Rubber In Shear (RIS) 2= Spring 3= Spring w/ Seismic Snubbers X= Special Code 20= Air Blender YY= None LC= Low CFM Air Blender XX= Special Code 2= Auxiliary Section Digit, Blow Thru Coil Section Y= None A= 33" Section B= 48" Section X= Special Digit 2, Blank Section between Coil and SA Fan Y= None A= 33" Section B= 48" Section X= Special Digit 3, Blank Section between Filter Section and Coil Y= None A= 33" Section B= 48" Section X= Special Digit 4, Blank Section between Economizer and Filter Section Y= None A= 33" Air Blender Section X= Special Due to design overlap, if the unit was built 996 thru 999, it is necessary to physically determine what parts were installed or contact Daikin Applied with model and serial number information in order to ensure that the correct part(s) are ordered. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 7

8 Unit Model Number- Complete Continued Code 22= Contractor Coil Section 996 & Earlier Digit, Coil Type Y= None C= Contractor Coil F= Contractor Coil w/ Face & Bypass X= Special Digit 2, Finned Length Y= None S= 36.0" L= 48.0" X= Special Digit 3, Coil Position Y= None A= Position # B= Position #2 C= Position # & 2 D= Position #2 & 3 E= Position #, 2, & 3 X= Special Digit 4, Filler Piece Height Y= None = 3.0" 2= 6.0" 3= 9.0" 4= 2.0" 5= 5.0" 6= 8.0" 7= 2.0" 8= 24.0" 9= 27.0" X= Special Code 22= Contractor Coil Section 999 & Later Digit, Coil Section Type Y= None C= Contractor Coil w/ Galvanized Drain Pan D= Contractor Coil w/ Stainless Steel Drain Pan F= Contractor Coil w/ Galvanized Drain Pan & F & BP G= Contractor Coil w/ Stainless Steel Drain Pan & F & BP X= Special Digit 2, Finned Length Y= None S= 36.0" L= 48.0" X= Special Digit 3, Coil Position Y= None A= Position # B= Position #2 C= Position # & 2 D= Position #2 & 3 E= Position # - 3 X= Special Digit 4, Coil Fin Height Y= 39.0" = 36.0" 2= 33.0" 3= 30.0" w/o F & B 4= 27.0" 5= 24.0" 6= 2.0" 7= 8.0" 8= 5.0" 9= 2.0" X= Special Code 23= Disconnect Switch/Field Power Connection Y= None A= SA Fan Only E= SA & RA Fans P= Power Block X= Special Code 24= Discharge Dampers YYYYYY= None (always 2000 & Later) D= Supply Air Dampers (999 & Earlier) B= Supply & Return Air Dampers (999 & Earlier) XXXXXX= Special Code 25= Approval Listings YYYY= None EYYY= ETL/MEA USA CYYYY= ETL Canada XXXX= Special Code 26= Parts Warranty A= Standard One Year Parts C= Extended One Year Parts, Two Year Total Z= Special Due to design overlap, if the unit was built 996 thru 999, it is necessary to physically determine what parts were installed or contact Daikin Applied with model and serial number information in order to ensure that the correct part(s) are ordered. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 8

9 Unit Model Number- Complete Continued Code 27= Packaging = Steel Skid 2= Consolidated Ship w/ Steel Skid F= Sheathed Crate D= Open Crate Code 28= Miscellaneous YYYY= None CCCC= Contractor Coil Sub-Item XXXX= Special Code 29= Latest Code Sheet Revision 996 & Earlier (_)= Revision Code 29= Position # Coil 999 & Later Y= None = With Coil Code 30= Latest Engineering Revision 5/999 & Before (_)= Revision Code 30= Position #2 Coil 5/999 & Later Y= None = With Coil Code 3= Position #3 Coil Y= None = With Coil Code 32= Supply Air Fan Drive Selection C Service Factor/Drive Type Required RPM XXXX= Special C= Std. SF/Variable Pitch Drive D= 50% SF/Variable Pitch Drive Code 33= Return Air Fan Drive Selection YYYY= None C Service Factor/Drive Type Required RPM XXXX= Special C= Std. SF/Variable Pitch Drive D= 50% SF/Variable Pitch Drive Code 34= Not an RDS708B Code Item YYYY= None Code 35= Latest Code Sheet Revision Y= None Due to design overlap, if the unit was built 996 thru 999, it is necessary to physically determine what parts were installed or contact Daikin Applied with model and serial number information in order to ensure that the correct part(s) are ordered. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 9

10 Typical Unit Layout Diagrams Economizer Damper Hood A B C D E G F Legend: A= Return Air Section B= Economizer Damper Section C= Filter Section D= Coil Section E= Supply Fan Section F= Discharge Plenum Section G= Power Panel/Main Control Box Economizer Damper Hood Outside Air Damper Hood 00% Outside Air Hood w/ or w/o Dampers Discharge Plenum Return Air Plenum Return Air Plenum w/ 0-30% Outside Air Hood Return Air Plenum w/ 0-00% Outdoor/Return Air Mixing Box Basic Front Discharge Unit 0-00% Outdoor/Return Air Section w/ optional Return Air Fan Down Discharge Unit The above drawings are to be used for representative purposes only. They do not show all available unit configurations. Actual unit layout depends upon options selected. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 0

11 Electrical Legend Schematic Sym. Description Location ACT3 Actuator Motor, Economizer Economizer Section ACT5 Actuator Motor, Discharge Isolation Damper Discharge Section ACT6 Actuator Motor, Return Air Isolation Damper Return Air Section ACT7 Actuator Motor, Heat Face/Bypass Coil Section, Heat ACT8 Actuator Motor, Cool Face/Bypass Coil Section, Cool CB Circuit Breaker, Supply/Return Fan Main Control Box DAT Sensor, Discharge Air Temperature Discharge Section DHL Duct High Limit Main Control Box DS Disconnect, Total Unit or Condenser/Heat Main Control Box EFT Sensor, Entering Fan Air Temperature Supply Fan Section F, FA, FB Fuse, Control Circuit, T Primary Power Panel/MC Box FC Fuse, Control Circuit, T Secondary Main Control Box FB9, 0 Fuseblock, Supply Fan Main Control Box FB, 20 Fuseblock, Return Fan Power Panel/MC Box FB3 Fuseblock, Transformer Main Control Box FS, FS2 Freezestat Coil Section, Heat/Cool GRD Ground All Control Boxes LAT Sensor, Leaving Air Temperature Energy Recovery Section LT0-23 Light, Cabinet Cabinet Sections OL, OL3 Relay, Overload Main Control Box M0 Contactor, Supply Fan Main Control Box M20 Contactor, Return Fan/Supply Fan Power Panel/MC Box M22 Contactor, Return Fan Power Panel MJ Mechanical Jumpers Terminal Blocks MMP0 Manual Motor Protector, Supply Fan Main Control Box MMP20 Manual Motor Protector, Return fan Main Control Box NB Neutral Bar Main Control Box OAT Outside Air Temperature Sensor Economizer Section PB Powerblock, Power Distribution Main Control Box R20 Relay, Steam, Hot Water Heat Main Control Box R26 Relay, Isolation/Exhaust Dampers Open/Close Main Control Box R28 Relay, Isolation Damper, Safety Main Control Box R29 Relay, Remote Fire Alarm Main Control Box R30 Relay, Cool Valve w/ F&B Main Control Box R45 Relay, UV Lights Main Control Box RAE Return Air Enthalpy Sensor Return Air Section RAT Return Air Temperature Sensor Return Air Section REC Receptacle, Main Box Main Control Box REC0-23 Receptacles, Cabinet Section Cabinet Sections S Switch, System On/Off Main Control Box S0-23 Switches, Cabinet Section Lights Cabinet Sections SD Smoke Detector, Supply Air Discharge Section SD2 Smoke Detector, Return Air Return Air Section T Transformer, Main Control Main Control Box TB Terminal Block, Internal Main Control Box TB2 Terminal Block, Field Main Control Box TB3 Terminal Block, Factory Main Control Box TB7 Terminal Block, 5V Convenience Outlet Main Control Box VFD0 VFD, Supply Fan Main Control Box VFD20 VFD, Return Fan Main Control Box VM Valve Motor, Heating Heating Section VM5 Valve Motor, Cooling Coil Section, Cool Damper Actuators and Temperature Sensors are NORMALLY field supplied, or supplied as special order items. Schematic designators are given for reference only. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page

12 Section A- Return Air Section Notes Primary Codes that pertain: 5, 8, 9, 33 Additional Codes that pertain: 04, 06, 07, 08, 09, 0, 2, 24 Code 5 is for the Return Air Plenum and determines if the unit has back (horizontal) return air or bottom return air. Code 5 also determines if a 00% Outside Air Hood and/or Damper are installed. If Code 5= J, K the unit has no outside air option, AND Code 8 must be Y (no 0-30% Outside Air OR 0-00% Economizer with Barometric Exhaust). Code 8 determines outdoor air options. Code 8= A indicates that the unit has 0-30% outside air selected. If Code 8= B the unit has a 0-00% Economizer with Barometric Exhaust in a 33" section and CANNOT have a Mixing Box. If Code 8= M the unit has a 0-00% Mixing Box with Hood, and Code 5 MUST be G (bottom discharge). Codes 9 & 33 determine the Return Air Fan Assembly, Motor, and Drive. Fan section parts, Fan Wheels, and Motors are listed in this section. Drive components (Fan Sheave, Motor Sheave, V-belt(s), and Sheave Bushing(s) [if required]) are NOT listed as they are unique to the unit. If a drive component is required you may use the number from the part and cross reference it in the Daikin Applied Parts catalog, The Daikin Parts E-Commerce site, or contact Daikin Applied with model and serial number information. Return Air Fan Motors range from - 5 horsepower, and the Fan Wheel can be either 5" x 5" Forward Curved (FC), OR a 6" Airfoil (AF). If Code 9= *D*G* OR *E*V*, Variable Inlet Vanes are present on the Return Fan. Note that the last unit supplied with Variable Inlet Vanes was built in late Code 04 specifies unit voltage. Unit voltage affects Fan Motor and Inverter (if supplied) part number identification. Code 06 determines the options selected in the Electrical Power Package. Code 07 indicates the type of liners and insulation specified. This affects sheet metal panel p/ns and configuration. Code 08 determines if the Return Fan has an Inverter, or Variable Frequency Drive (VFD). If Code 08 does NOT equal YY, then the unit has inverters, and cannot have Fan Wheels with Variable Inlet Vanes. Inverters are not available on 575V units (Code 04= 37). For Inverter p/ns see Section G- Power Panel/Main Control Box. Code 09 determines if the Return Air Cabinet has a Light Fixture, Light Switch, and 5V Receptacle (Code 09= B, C). Code 0 determines the type and efficiency rating of the Return Fan Motor. Code 2 indicates whether the Return Fan is equipped with a Belt Guard. Code 2= B indicates that the Return Fan only has a Belt Guard, and Code 2= C indicates that both the Return and Supply Fan drives are equipped with a Belt Guard. For units built 999 and before, Code 24 indicates the presence of Return Air Fan Dampers. If Code 24= B, the Supply AND Return Fans are supplied with dampers. Return Air Dampers are not available with 6" AF Fan Wheels. Note: Temperature and Air Pressure Sensors, and Damper Actuators are NOT normally factory supplied. If such parts are present they would have been special order items, or they would have been field supplied. Contact Daikin Applied with model and serial number information as well as all available vendor and p/n information to see if the required part(s) can be identified and sourced. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 2

13 Section A- Return Air Section 0-30% Outside Air Damper with Hood Code 8= A 2 See Detail Below Outside Air Hood Detail Detail A Ref. Part Part Qty. No. Description Number 2 Damper/Hood Assy Outside Air Screen Blade, Damper Bearing, Flange Nylon Bell Arm Assy Ball Joint Rod, Damper This Damper Assembly is set up for manual operation only. Any actuators would be field supplied, or supplied as special order items. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 3

14 Section A- Return Air Section 0-00% Outside Air Damper with Hood: Code 5= K (After 3/04) & 00% Hood w/o Damper: Code 5= J Ref. Part Part Qty. No. Description Number 3 Damper Panel, Hood Outside Air Screen Damper Assy., 44" x 32.5", Crank Arm The Damper Assembly used before 3/04 is obsolete and NO LONGER AVAILABLE. The Damper Assembly listed above is NOT a direct replacement and will NOT fit in units built before 3/04 WITHOUT FIELD MODIFICATIONS. 2 This Damper Assembly is set up for manual operation only. Any Actuators would be field supplied, or supplied as special order items. 3 When Code 5= J, use Damper Panel, Hood p/n For additional parts, contact Daikin Applied with model and serial number information. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 4

15 Section A- Return Air Section 0-00% Outside Air Damper Mixing Box with Hood Code 8= M (After 3/04) See Detail at Left Damper Linkage Detail Ref. Part Part Qty. No. Description Number 5 Damper Panel, Hood Outside Air Screen Rod, Damper Linkage Damper Assy., 48" x 22.5", Crank Arm Ball Joint The Damper Assembly used before 3/04 is obsolete and NO LONGER AVAILABLE. The Damper Assembly listed above is NOT a direct replacement and will NOT fit in units built before 3/04 WITHOUT FIELD MODIFICATIONS. Note that when replacing an original damper assembly, it is recommended to replace BOTH dampers at the same time so that the Damper Linkage will operate correctly. 2 This Damper Assembly is set up for manual operation only. Any actuators would be field supplied, or supplied as special order items. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 5

16 Section A- Return Air Section Return Fan Dampers: Code 24= B Ref. Part Part Qty. No. Description Number 5" x 5" Fan Wheel Code 9= *D*** Damper, Horizontal Discharge Code 4= H, Y Damper, Downblast Discharge Code 4= D, G Return Air Dampers are NOT available for units built 999 and Later AND for 6" AF Wheel equipped units (Code 9= *E***). Diagram shows front OR horizontal discharge unit configuration (Code 4= H, Y). This Damper Assembly is set up for manual operation only. Any actuators would be field supplied, or supplied as special order items. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 6

17 Section A- Return Air Section Return Fan Assemblies 5" x 5" Forward Curved Fan w/o Variable Inlet Vanes- Diagram Code 9= *D*F* Motor (See Motor list at the end of the Fan mounting section.) Motor Sheave Fan Sheave 33 Drive components (Fan Sheave, Motor Sheave, V-belt(s), and Sheave Bushing(s) [if required]) are NOT listed as they are unique to the unit. If a drive component is required you may use the number from the part and cross reference it in the Daikin Applied Parts catalog, The Daikin Parts E-Commerce site, or contact Daikin Applied with model and serial number information. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 7

18 Section A- Return Air Section Return Fan Assemblies 5" x 5" Forward Curved Fan w/o Variable Inlet Vanes- Components Code 9= *D*F* Ref. Part Part Qty. No. Description Number 2 Wheel/Housing Assy Motor Mount Shaft Key- Motor Sheave Bolt- Motor Mount Key- Fan Sheave Bearing N/S Belt Guard N/S= Not Shown on diagram. Note: Motors are listed after the fan mounting section. Drive components (Fan Sheave, Motor Sheave, V-belt(s), and Sheave Bushing(s) [if required]) are NOT listed as they are unique to the unit. If a drive component is required you may use the number from the part and cross reference it in the Daikin Applied Parts catalog, The Daikin Parts E-Commerce site, or contact Daikin Applied with model and serial number information. Code 2= A, C. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 8

19 Section A- Return Air Section Return Fan Assemblies 5" x 5" Forward Curved Fans w/ Variable Inlet Vanes- Diagrams Code 9= *D*G* Motor (See Motor list at the end of the Fan mounting section.) Motor Sheave Fan Sheave Drive components (Fan Sheave, Motor Sheave, V-belt(s), and Sheave Bushing(s) [if required]) are NOT listed as they are unique to the unit. If a drive component is required you may use the number from the part and cross reference it in the Daikin Applied Parts catalog, The Daikin Parts E-Commerce site, or contact Daikin Applied with model and serial number information. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 9

20 Section A- Return Air Section Return Fan Assemblies 5" x 5" Forward Curved Fans w/ Variable Inlet Vanes- Components Code 9= *D*G* Ref. Part Part Qty. No. Description Number 2 Wheel/Housing Assy Motor Mount Shaft Key- Motor Sheave Bolt- Motor Mount Key- Fan Sheave Bearing N/S Belt Guard Inlet Vane Assy. CW Inlet Vane Assy. CCW Crankarm Bearing, Flange Shaft, Support Ball Joint Damper Rod Mount, Actuator Plate, Linkage N/S= Not Shown on diagram. Note: Motors are listed after the fan mounting section. Drive components (Fan Sheave, Motor Sheave, V-belt(s), and Sheave Bushing(s) [if required]) are NOT listed as they are unique to the unit. If a drive component is required you may use the number from the part and cross reference it in the Daikin Applied Parts catalog, The Daikin Parts E-Commerce site, or contact Daikin Applied with model and serial number information. Code 2= A, C. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 20

21 Section A- Return Air Section Return Fan Assemblies 6" Airfoil Fans w/o Variable Inlet Vanes- Diagram Code 9= *E*A* 9 Motor (See Motor list at the end of the Fan mounting section.) Notes: Horizontal Discharge arrangement shown. Drive components (Fan Sheave, Motor Sheave, V-belt(s), and Sheave Bushing(s) [if required]) are NOT listed as they are unique to the unit. If a drive component is required you may use the number from the part and cross reference it in the Daikin Applied Parts catalog, The Daikin Parts E-Commerce site, or contact Daikin Applied with model and serial number information. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 2

22 Section A- Return Air Section Return Fan Assemblies 6" Airfoil Fans w/o Variable Inlet Vanes- Components Code 9= *E*A* Ref. Part Part Qty. No. Description Number 2 Wheel/Housing Assy Housing Only Motor Mount Shaft Key- Motor Sheave Bolt- Motor Mount Key- Fan Sheave Bearing Wheel Cutoff Plate Inlet Funnel Inlet Funnel N/S Belt Guard N/S= Not Shown on diagram. Note: Motors are listed after the fan mounting section. Drive components (Fan Sheave, Motor Sheave, V-belt(s), and Sheave Bushing(s) [if required]) are NOT listed as they are unique to the unit. If a drive component is required you may use the number from the part and cross reference it in the Daikin Applied Parts catalog, The Daikin Parts E-Commerce site, or contact Daikin Applied with model and serial number information. Assy. includes Housing, Wheel, Cutoff Plate, and Grease Tubing. 2 Included in Wheel/Housing Assy Code 2= A, C. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 22

23 Section A- Return Air Section Return Fan Assemblies 6" Airfoil Fans with Variable Inlet Vanes- Diagrams Code 9= *E*V* Motor (See Motor list at the end of the Fan mounting section.) Inlet Guide Vane Detail (See the following two pages) Notes: Horizontal Discharge arrangement shown. Drive components (Fan Sheave, Motor Sheave, V-belt(s), and Sheave Bushing(s) [if required]) are NOT listed as they are unique to the unit. If a drive component is required you may use the number from the part and cross reference it in the Daikin Applied Parts catalog, The Daikin Parts E-Commerce site, or contact Daikin Applied with model and serial number information. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 23

24 Section A- Return Air Section Return Fan Assemblies 6" Airfoil Fans with Variable Inlet Vanes- Diagrams, Continued Code 9= *E*V* 37 Inlet Guide Vane Detail A A Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 24

25 Section A- Return Air Section Return Fan Assemblies 6" Airfoil Fans with Variable Inlet Vanes- Components Code 9= *E*V* Ref. Part Part Qty. No. Description Number 2 Wheel/Housing Assy Housing Only Motor Mount Shaft Key- Motor Sheave Bolt- Motor Mount Key- Fan Sheave Bearing N/S Wheel Cutoff Plate Inlet Vane Assy. CW Inlet Vane Assy. CCW N/S Belt Guard Linkage Rod Assy A Bearing, Flange Ball Joint Linkage Rod Ball Joint Linkage Rod Linkage Mount N/S= Not Shown on diagram. Note: Motors are listed after the fan mounting section. Drive components (Fan Sheave, Motor Sheave, V-belt(s), and Sheave Bushing(s) [if required]) are NOT listed as they are unique to the unit. If a drive component is required you may use the number from the part and cross reference it in the Daikin Applied Parts catalog, The Daikin Parts E-Commerce site, or contact Daikin Applied with model and serial number information. Assy. includes Housing, Wheel, Cutoff Plate, and Grease Tubing. 2 Included in Wheel/Housing Assy Code 2= A, C. 4 Included in Linkage Rod Assy Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 25

26 Section A- Return Air Section Return Air Fan Mounting- 5" x 5" Forward Curved Fan Code 9= *D*F, *D*F2, *D*G, *D*G2 Rubber In Shear Code 9= *D*F, *D*G Ref. Part Part Qty. No. Description Number 46 Rubber Isolator R- 2 Blue Screw.32-8 x.0" Washer, Lock Screw x.0" Nut Washer, Lock Quantity listed is for ONE corner. All four corners are the same. Spring Mounting Code 9= *D*F2, *D*G Ref. Part Part Qty. 2 No. Description Number 43 Spring Isolator- w/o VIV Code 9= *D*F2 Motor H.P.= ALL Blue Spring Isolator- w/ VIV Code 9= *D*G2 Motor H.P.= ALL Orange Spring Isolator- w/o VIV Code 9= *D*F2 Motor H.P.= ALL Orange Spring Isolator- w/ VIV Code 9= *D*G2 Motor H.P.= thru 3 Orange Motor H.P.= 5 Brown Spring Isolator- w/o VIV Code 9= *D*F2 Motor H.P.= ALL Blue Spring Isolator- w/ VIV Code 9= *D*G2 Motor H.P.= ALL Blue Spring Isolator- w/o VIV Code 9= *D*F2 Motor H.P.= ALL Orange Spring Isolator- w/ VIV Code 9= *D*G2 Motor H.P.= thru 2 Blue Motor H.P.= 3 thru 5 Orange Screw x.0" Washer Washer, Lock Screw.32-8 x.0" Washer, Lock Screw x.0" Nut Washer, Lock Quantity listed is for ONE corner. All four corners are the same. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 26

27 Section A- Return Air Section Return Air Fan Mounting- 5" x 5" Forward Curved Fan Seismic Mounting: Code 9= *D*F3, *D*G Seismic Mounting Detail Ref. Part Part Qty. No. Description Number 43 Spring Isolator- w/o VIV Code 9= *D*F3 Motor H.P.= ALL Blue Spring Isolator- w/ VIV Code 9= *D*G3 Motor H.P.= ALL Orange Spring Isolator- w/o VIV Code 9= *D*F3 Motor H.P.= ALL Orange Spring Isolator- w/ VIV Code 9= *D*G3 Motor H.P.= thru 3 Orange Motor H.P.= 5 Brown Spring Isolator- w/o VIV Code 9= *D*F3 Motor H.P.= ALL Blue Spring Isolator- w/ VIV Code 9= *D*G3 Motor H.P.= ALL Blue Spring Isolator- w/o VIV Code 9= *D*F3 Motor H.P.= ALL Orange Spring Isolator- w/ VIV Code 9= *D*G3 Motor H.P.= thru 2 Blue Motor H.P.= 3 thru 5 Orange Screw x.0" Washer Washer, Lock Screw.32-8 x.0" Washer, Lock Screw x.0" Nut Washer, Lock Washer Washer, Neoprene Spacer, Neoprene Spacer Screw x 3.0" Washer, Lock Washer Washer, Lock Nut Screw Washer, Lock Quantity listed is for ONE corner. All four corners are the same. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 27

28 Section A- Return Air Section Return Air Fan Mounting- 6" Airfoil Fan Code 9= *E*A, *E*A2, *E*V, *E*V2 Rubber In Shear Code 9= *E*A, *E*V Ref. Part Part Qty. No. Description Number 46 Rubber Isolator R- 2 Blue Screw.32-8 x.0" Washer, Lock Screw x.0" Nut Washer, Lock Quantity listed is for ONE corner. All four corners are the same. Spring Mounting Code 9= *E*A2, *E*V Ref. Part Part Qty. 2 No. Description Number 43 Spring Isolator- w/o VIV Code 9= *E*A2 Motor H.P.= ALL Orange Spring Isolator- w/ VIV Code 9= *E*V2 Motor H.P.= ALL Orange Spring Isolator- w/o VIV Code 9= *E*A2 Motor H.P.= thru 3 Orange Motor H.P.= 5 Brown Spring Isolator- w/ VIV Code 9= *E*V2 Motor H.P.= thru 3 Orange Motor H.P.= 5 Brown Spring Isolator- w/o VIV Code 9= *E*A2 Motor H.P.= ALL Blue Spring Isolator- w/ VIV Code 9= *E*V2 Motor H.P.= ALL Blue Spring Isolator- w/o VIV Code 9= *E*A2 Motor H.P.= thru 2 Blue Motor H.P.= 3 thru 5 Orange Spring Isolator- w/ VIV Code 9= *E*V2 Motor H.P.= thru 2 Blue Motor H.P.= 3 thru 5 Orange Screw x.0" Washer Washer, Lock Screw.32-8 x.0" Washer, Lock Screw x.0" Nut Washer, Lock Quantity listed is for ONE corner. All four corners are the same. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 28

29 Section A- Return Air Section Return Air Fan Mounting- 6" Airfoil Fan Seismic Mounting: Code 9= *E*A3, *E*V Seismic Mounting Detail Ref. Part Part Qty. No. Description Number 43 Spring Isolator- w/o VIV Code 9= *E*A3 Motor H.P.= ALL Orange Spring Isolator- w/ VIV Code 9= *E*V3 Motor H.P.= ALL Orange Spring Isolator- w/o VIV Code 9= *E*A3 Motor H.P.= thru 3 Orange Motor H.P.= 5 Brown Spring Isolator- w/ VIV Code 9= *E*V3 Motor H.P.= thru 3 Orange Motor H.P.= 5 Brown Spring Isolator- w/o VIV Code 9= *E*A3 Motor H.P.= ALL Blue Spring Isolator- w/ VIV Code 9= *E*V3 Motor H.P.= ALL Blue Spring Isolator- w/o VIV Code 9= *E*A3 Motor H.P.= thru 2 Blue Motor H.P.= 3 thru 5 Orange Spring Isolator- w/ VIV Code 9= *E*V3 Motor H.P.= thru 2 Blue Motor H.P.= 3 thru 5 Orange Screw x.0" Washer Washer, Lock Screw.32-8 x.0" Washer, Lock Screw x.0" Nut Washer, Lock Washer Washer, Neoprene Spacer, Neoprene Spacer Screw x 3.0" Lock Washer Washer Washer, Lock Nut Quantity listed is for ONE corner. All four corners are the same. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 29

30 Section A- Return Air Section Fan Motors Motor H.P. Unit ODP HiEff ODP PrEff. TEFC HiEff TEFC PrEff H.P. Code 9 Voltage C0= H 2, E C0= J C0= H 3 C0= K C04= 2.0 E**** 208/60/ F**** 208/60/ G**** 208/60/ H**** 208/60/ J**** 208/60/ C04= 29.0 E**** 230/60/ F**** 230/60/ G**** 230/60/ H**** 230/60/ J**** 230/60/ C04= 27.0 E**** 460/60/ F**** 460/60/ G**** 460/60/ H**** 460/60/ J**** 460/60/ C04= 37.0 E**** 575/60/ F**** 575/60/ G**** 575/60/ H**** 575/60/ J**** 575/60/ Note that Standard Efficiency Motors (Code 0= Y, A, G) are no longer available. Use HiEff or PrEff Motors (Code 0= E, H, J, K) instead. 2 Code used for units built before 9/ Code used for units built after 9/ Contact Daikin Applied with model and serial number information, and vendor p/n (if available) so that the correct Motor can be identified. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 30

31 Section A- Return Air Section Miscellaneous Electrical Components: LT, S, REC Light Fixture Detail See Detail at Right Ref. Part Part Qty. No. Description Number 25 Light Fixture- LT Bulb Box, Electrical Cover, Electrical Box Light Switch- S Receptacle- REC Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 3

32 Section B- Economizer Damper Section Notes Primary Codes that pertain: 5, 8 Additional Codes that pertain: 07 Code 5 (Return Air Plenum) and Code 8 (Outdoor Air options for units built 999 & Later) determine outside air options. If Code 8= B the unit has an Economizer and CANNOT have a Mixing Box. Code 5 CANNOT be Y (no Return Air Plenum/Section) if the unit has an Economizer. Code 07 indicates the type of liners and insulation specified. This affects sheet metal panel p/ns and configuration. Note: Temperature and Air Pressure Sensors, and Damper Actuators are NOT normally factory supplied. If such parts are present they would have been special order items, or they would have been field supplied. Contact Daikin Applied with model and serial number information as well as all available vendor and p/n information to see if the required part(s) can be identified and sourced. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 32

33 Section B- Economizer Damper Section Economizer Dampers: Code 8= B 7 Economizer Damper Detail See Detail at Left Ref. Part Part Qty. No. Description Number 8 Panel, Damper Support 46" x 2" Panel, Damper Support 49" x 8" Damper Assy, Low Leak 44.2" x 30.7" Damper Blade, Low Leak Linkage Bar, Damper N/S Damper End Plug, Non Driven Damper End Plug, w/ Drive Tab Bushing, Damper Blade Bushing, Damper Linkage Gasket, Damper Blade Damper Assy, Low Leak 44.2" x 30.7" Damper Blade, Low Leak Linkage Bar, Damper N/S Damper End Plug, Non Driven Damper End Plug, w/ Drive Tab Bushing, Damper Blade Bushing, Damper Linkage Gasket, Damper Blade Linkage Bar Damper Rod Ball Joint, Damper Bushing, Damper Linkage Locking Collar N/S= Not shown on diagram. This Damper Assembly is set up for manual operation only. Any actuators would be field supplied, or supplied as special order items. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 33

34 Section C- Filter/Final Filter Section Notes Primary Codes that pertain: 03,, 3, 7 Additional Codes that pertain: 07 Codes 03 and determine if the unit has a 33" Final Filter Section OR a 33" Blank (empty) Section. If Code = BBBB, F*** the unit has a Final Filter Section located after the Heat Section. When a Final Filter section is provided, a Blank section and a Discharge Plenum are required. If Code = FE** the unit has a Final Filter Section located after the Heat Section equipped with 95% efficient Flat Cartridge Filters. If Code = AAAA OR B*** AND Code 03= B the unit is equipped with a 33" Blank Section located after the Heat Section. If Code = FY** a Filter Section and rack were included, but filter media was NOT factory supplied. Code 7 determines Filter Section characteristics. Due to some design overlap during the transition from Bag to Cartridge Filters, for units built between 996 and 999, contact Daikin Applied with model and serial number information in order that the correct filters are identified. Also, some older design filters and related parts may be obsolete and no longer available. If this is the case, contact Daikin Applied for more information. For Units built 996 & Before: Code 7= A= 2" Throwaway Filters B= 2" Cleanable Filters C= Bag Type, 45% w/o Prefilters D= Bag Type, 45% w/ Prefilters E= Bag Type, 95% w/ Prefilters F= A + B w/ No Filters provided G= 2" 35% Pleated Throwaway For Units Built 999 & Later: Code 7= A= Angular Rack w/ Throwaway Filters B= Angular Rack w/ Cleanable Filters C= Angular Rack Only G= Angular Rack w/ 30% Filters D= Flat Rack with 65% Cartridge Filters E= Flat with 95% Cartridge Filters F= Flat Rack Only Code 07 indicates the type of liners and insulation specified. This affects sheet metal panel p/ns and configuration. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 34

35 Section C- Filter/Final Filter Section Filter Section Assembly: 996 & Before 5" x 6" FC Fans: Code 3= *A*** Ref. Part Part Qty./ No. Description Number Unit N/S Filter, Throwaway 20" x 25" x 2" N/S Filter, Cleanable 20" x 25" x 2" N/S Filter, Pleated Throwaway- 35% Efficient 20" x 25" x 2" N/S Pre-Filter, Throwaway (For Bag Type) 2"x 24" x 2" N/S Pre-Filter, Throwaway (For Bag Type) 24"x 24" x 2" Filter, Bag Type- 45% Efficient.38" x 23.88" x 22" Filter Basket- 45% Efficient.38" x 23.88" x 22" Filter Frame- 45% Efficient.38" x 23.88" x 22" Filter Retainer- 45% Efficient.38" x 23.88" x 22" Filter, Bag Type- 45% Efficient 23.38" x 23.88" x 22" Filter Basket- 45% Efficient 23.38" x 23.88" x 22" Filter Frame- 45% Efficient 23.38" x 23.88" x 22" Filter Retainer- 45% Efficient 23.38" x 23.88" x 22" N/S Filter, Bag Type- 95% Efficient 24" x 24" x 26"/30" N/S Filter, Blank- Flat or no Filters 9.62" x 25" N/S Filter, Blank- 45% Efficient Bag Type.38" x.38" N/S Filter, Blank- 45%/95 Efficient Bag Type.38" x 23.88" N/S Filter, Blank- 45%/95 Efficient Bag Type.38" x 23.88" N/S Filter, Blank- 45%/95 Efficient Bag Type.38" x.38" N/S= Not shown on diagram. Due to some design overlap during the transition from Bag to Cartridge Filters, for units built between 996 and 999, contact Daikin Applied with model and serial number information in order that the correct filters are identified. Also, some filters and related parts may be obsolete and no longer available. If this is the case, contact Daikin Applied for more information. Note that 6" Airfoil fans were not offered at this time. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 35

36 Section C- Filter/Final Filter Section Filter Section Assembly: 996 & Before, Continued 5" x 9" & 5" x 5" FC Fans: Code 3= *B***, *C*** Ref. Part Part Qty./ No. Description Number Unit N/S Filter, Throwaway 20" x 25" x 2" N/S Filter, Cleanable 20" x 25" x 2" N/S Filter, Pleated Throwaway- 35% Efficient 20" x 25" x 2" N/S Pre-Filter, Throwaway (For Bag Type) 2"x 24" x 2" N/S Pre-Filter, Throwaway (For Bag Type) 24"x 24" x 2" Filter, Bag Type- 45% Efficient.38" x 23.88" x 22" Filter Basket- 45% Efficient.38" x 23.88" x 22" Filter Frame- 45% Efficient.38" x 23.88" x 22" Filter Retainer- 45% Efficient.38" x 23.88" x 22" Filter, Bag Type- 45% Efficient 23.38" x 23.88" x 22" Filter Basket- 45% Efficient 23.38" x 23.88" x 22" Filter Frame- 45% Efficient 23.38" x 23.88" x 22" Filter Retainer- 45% Efficient 23.38" x 23.88" x 22" N/S Filter, Bag Type- 95% Efficient 2" x 24" x 26"/30" N/S Filter, Bag Type- 95% Efficient 2" x 24" x 26"/30" Filter, Blank- 45%/95 Efficient.38" x 23.88" Filter, Blank- 45%/95 Efficient.38" x.38" N/S= Not shown on diagram. Due to some design overlap during the transition from Bag to Cartridge Filters, for units built between 996 and 999, contact Daikin Applied with model and serial number information in order that the correct Filters are identified. Also, some Filters and related parts may be obsolete and no longer available. If this is the case, contact Daikin Applied for more information. Note that 6" Airfoil Fans were not offered at this time. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 36

37 Section C- Filter/Final Filter Section Filter Section Assembly: Filters 999 & Later Angular Filter Section: Code 7= A, B, G AND/OR Code = F*E** Ref. Part Code Part Qty. No. Description 7= Number 5" x 6" FC Fan: Code 3= *A*** 5 Filter Throwaway A, G Cleanable B Filter, Blank Off ALL " x 9", 5 x 5" FC Fan: Code 3= *B***, *C** 5 Filter Throwaway A, G Cleanable B Filter Throwaway A, G Cleanable B " AF Fan: Code 3= *E*** 5 Filter Throwaway A, G Cleanable B Filter Throwaway A, G Cleanable B Due to some design overlap during the transition from Bag to Cartridge Filters, for units built between 996 and 999, contact Daikin Applied with model and serial number information in order that the correct Filters are identified. Also, some Filters and related parts may be obsolete and no longer available. If this is the case, contact Daikin Applied for more information. 2 Code = F*E** indicates that the unit has a 33" Final Filter Section equipped with 95% efficient Cartridge Filters. The Filters and Filter quantity are the same regardless of the coding Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 37

38 Section C- Filter/Final Filter Section Filter Section Assembly: Filters 999 & Later, Continued Cartridge Filter Section: Code 7= D, E AND/OR Code = F*E** Ref. Part Code Part Qty. No. Description 7= Number 5" x 6" FC Fan: Code 3= *A*** 5, 9 Filter 24 x 24 x 2" 65% Efficient Cartridge D % Efficient Cartridge E , 20, 23 Filter 2 x 24 x 2" 65% Efficient Cartridge D % Efficient Cartridge E " x 9", 5 x 5" FC Fan: Code 3= *B***, *C** 5, 9 Filter 24 x 24 x 2" 65% Efficient Cartridge D % Efficient Cartridge E , 20, 23 Filter 2 x 24 x 2" 65% Efficient Cartridge D % Efficient Cartridge E Pre-Filter 2 x 24 x 2" ALL " AF Fan: Code 3= *E*** 5, 9 Filter 24 x 24 x 2" 65% Efficient Cartridge D % Efficient Cartridge E , 20, 23 Filter 2 x 24 x 2" 65% Efficient Cartridge D % Efficient Cartridge E , 2 Pre-Filter 24 x 24 x 2" ALL , 25 Pre-Filter 2 x 24 x 2" ALL Filter, Blank Off ALL Due to some design overlap during the transition from Bag to Cartridge Filters, for units built between 996 and 999, contact Daikin Applied with model and serial number information in order that the correct Filters are identified. Also, some Filters and related parts may be obsolete and no longer available. If this is the case, contact Daikin Applied for more information. 2 Code = F*E** indicates that the unit has a 33" Final Filter Section equipped with 95% efficient Cartridge Filters. The Filters and Filter quantity are the same regardless of the coding Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 38

39 Section D- Coil Section Notes Primary Codes that pertain: 22, 29, 30, 3 Additional Codes that pertain: 07, 2 Code 22 determines Coil options, size, and Coil position in the Draw-Thru Coil Section. Code 22 also indicates whether the unit has a galvanized steel OR stainless steel Drain pan, and if the unit is equipped with a Face and Bypass Damper. If Code 22= C***, F*** the unit has a galvanized steel Drain Pan. If Code 22= D***, G*** the unit has a stainless steel Drain pan. Code 22= F***, G*** indicates that the unit is equipped with a Face and Bypass Damper. Refer to the box below for information regarding ordering replacement coils. Codes 29, 30, 3 (for units built 999 & Later) indicate if a Contractor Coil is installed in coil positions one through three. Refer to the box below for information regarding ordering replacement coils for ALL RDS708B units. Code 07 indicates the type of liners and insulation specified. This affects sheet metal panel p/ns and configuration. Code 2 gives information regarding the selection of auxiliary unit sections. Also included in this section is the p/n for an optional field installed Piping Vestibule. A Piping Vestibule is recommended when piping must enter the side of the unit. It is also required on many coil arrangements to facilitate piping through the roof curb. The Vestibule listed is designed to fit a standard 48" Coil Section. All RDS708B units that have heating or cooling capability are equipped with Contractor Coils. Contractor Coils are offered in multiple fin heights to allow the user to select the coil size to match the air flow. Contractor Coils generally offer a wider range of circuitings, rows and fins, and materials than the standard Unit Coil. Contractor Coils are ordered as separate line items on the GO (General Order), so they DO NOT have orderable or "hard/permanent" part numbers. A Contractor coil is ALWAYS quoted as needed when needed. When a replacement Coil is required a Contractor Coil quote needs to be prepared. To quote a replacement Contractor Coil it is necessary to obtain model and serial number information from the Unit Nameplate and then contact Daikin Applied. If the unit has more than one Coil it will be necessary to confirm which Coil(s) are needed BEFORE quoting. Note that the sample code strings shown on the following page are INCOMPLETE and DO NOT furnish enough information for Daikin Applied to quote. GO and/or serial number information is required in order to properly quote a Contractor Coil. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 39

40 Section D- Coil Section Contractor Coil Code Strings Note that these sample codes are incomplete and DO NOT provide sufficient information to quote a Coil. Refer to the notes on the previous page for information on having a Contractor Coil quoted. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 40

41 Section D- Coil Section Drain Pans & Piping Vestibule Coil(s) (refer to the Notes two pages previous) Piping Vestibule Detail Air Flow 2 Coil Section 3 Ref. Part Part Qty. No. Description Number 2 Drain Pan Coil Finned Length 36" Galvanized Code 22= CS**, FS** Stainless Steel Code 22= DS**, GS** Coil Finned Length 48" Galvanized Code 22= CL**, FL** Stainless Steel Code 22= DL**, GL** Piping Vestibule Kit (field installed for a 48" Section) Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 4

42 Section D- Coil Section Face & Bypass Dampers 7 Coil(s) (refer to the Notes three pages previous) Drain Pan Ref. Part Part Qty. No. Description Number 7 Damper, Face & Bypass Coil Finned Length 36" Code 22= FS** Coil Finned Length 48" Code 22= FL** This Damper Assembly is set up for manual operation only. Any Actuators would be field supplied, or supplied as special order items. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 42

43 Section E- Supply Air Section Notes Primary Codes that pertain: 3, 32 Additional Codes that pertain: 04, 06, 07, 08, 09, 0, 2, 24 Codes 3 & 32 determine the Supply Air Fan Assembly, Motor, and Drive Components. Fan section parts, Fan Wheels, and Motors are listed in this section. Drive components (Fan Sheave, Motor Sheave, V-belt(s), and Sheave Bushing(s) [if required]) are NOT listed as they are unique to the unit. If a drive component is required you may use the number from the part and cross reference it in the Daikin Applied Parts catalog, The Daikin Parts E-Commerce site, or contact Daikin Applied with model and serial number information. Fan Motors range from -0 horsepower, and the Fan Wheel can be 5" x 6", 5" x 9", 5" x 5" Forward Curved (FC), OR 6" Airfoil (AF). Code 3 also determines if Variable Inlet Vanes (VIV) are present and what type of fan isolation is specified (Rubber-In-Shear OR Spring Isolators). If Code 3= ***G*, ***V*, Variable Inlet Vanes are present on the Supply Fan. Note that the last unit supplied with Variable Inlet Vanes was built in late Code 04 specifies unit voltage. Unit voltage affects Fan Motor and Inverter (if supplied) part number. Code 06 determines the options selected in the Electrical Power Package. Code 08 determines if the Supply Air Fan has an inverter, or Variable/Adjustable Frequency Drive (VFD/AFD). If Code 08 does NOT equal YY, then the unit has inverters, and cannot have Fan Wheels with Variable Inlet Vanes. Inverters are not available for 575V units (Code 04= 37). For Inverter p/ns see Section G- Power Panel/ Main Control Box. Code 09 determines if the Supply Air Cabinet has a Light Fixture, Light Switch, and 5V Receptacle (Code 09= A, C). Code 0 determines the type and efficiency rating of the Fan Motor. Code 2 indicates whether the Supply Fan is equipped with a Belt Guard. Code 2= A indicates that the Supply Fan only has a Belt Guard and Code 2= C indicates that both the Supply and Return Fan drives are equipped with a Belt Guard. Code 24 indicates the presence of Supply Air Fan Dampers. If Code 24= D, the Supply Air Section is supplied with a Damper. If Code 24= B, the Supply AND Return Fans are supplied with Dampers. Supply Air Dampers are not available with 6" AF Fan Wheels (Code 3= *E***) AND/OR on any unit built 999 & Later. Note: Temperature and Air Pressure Sensors, and Damper Actuators are NOT normally factory supplied. If such parts are present they would have been special order items, or they would have been field supplied. Contact Daikin Applied with model and serial number information as well as all available vendor and p/n information to see if the required part(s) can be identified and sourced. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 43

44 Section E- Supply Air Section Supply Fan Dampers: Code 24= D, B Ref. Part Part Qty. No. Description Number 5" x 6" Fan Wheel Code 3= *A*F* Damper, Horizontal Discharge Code 4= H, Y Damper, Downblast Discharge Code 4= D, G " x 9" Fan Wheel Code 3= *B*F* Damper, Horizontal Discharge Code 4= H, Y Damper, Downblast Discharge Code 4= D, G " x 5" Fan Wheel Code 3= *C*** Damper, Horizontal Discharge Code 4= H, Y Damper, Downblast Discharge Code 4= D, G Supply Air Dampers are not available for units built 999 and later and for 6" AF Wheel equipped units (Code 3= *E***). Diagram shows front OR horizontal discharge unit configuration (Code 4= H, Y). This Damper Assembly is set up for manual operation only. Any actuators would be field supplied, or supplied as special order items. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 44

45 Section E- Supply Air Section Fan Assemblies 5" Forward Curved Fans w/o Inlet Vanes- Diagram Code 3= *A*F*, *B*F*, *C*F* Motor (See Motor list at the end of the Fan mounting section.) Motor Sheave Fan Sheave 8 Drive components (Fan Sheave, Motor Sheave, V-belt(s), and Sheave Bushing(s) [if required]) are NOT listed as they are unique to the unit. If a drive component is required you may use the number from the part and cross reference it in the Daikin Applied Parts catalog, The Daikin Parts E-Commerce site, or contact Daikin Applied with model and serial number information. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 45

46 Section E- Supply Air Section Fan Assemblies 5" Forward Curved Fans w/o Inlet Vanes- Components Code 3= *A*F*, *B*F*, *C*F* Ref. Part Fan Size: Code 3= Qty. No. Description *A*F* *B*F* *C*F* 2 Wheel/Housing Assy Motor Mount Shaft Key- Motor Sheave Shim- Bearing Not Used 4 7 Bolt- Motor Mount Key- Fan Sheave Bearing- Pillow Block N/S Belt Guard Assy N/S= Not Shown on diagram. Note: Motors are listed after the fan mounting section. Drive components (Fan Sheave, Motor Sheave, V-belt(s), and Sheave Bushing(s) [if required]) are NOT listed as they are unique to the unit. If a drive component is required you may use the number from the part and cross reference it in the Daikin Applied Parts catalog, The Daikin Parts E-Commerce site, or contact Daikin Applied with model and serial number information. These are concentric locking collar Bearings. They are direct replacements for the original setscrew locking Bearings. 2 Code 2= A, C. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 46

47 Section E- Supply Air Section Fan Assemblies 5" x 5" Forward Curved Fan w/ Inlet Vanes- Diagrams Motor (See Motor list at the end of the Fan mounting section.) Motor Sheave Code 3= *C*G* Fan Sheave Drive components (Fan Sheave, Motor Sheave, V-belt(s), and Sheave Bushing(s) [if required]) are NOT listed as they are unique to the unit. If a drive component is required you may use the number from the part and cross reference it in the Daikin Applied Parts catalog, The Daikin Parts E-Commerce site, or contact Daikin Applied with model and serial number information. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 47

48 Section E- Supply Air Section Fan Assemblies 5" x 5" Forward Curved Fan w/ Inlet Vanes- Components Code 3= *C*G* Ref. Part Part Qty. No. Description Number 2 Wheel/Housing Assy Motor Mount Shaft Key- Motor Sheave Bolt- Motor Mount Key- Fan Sheave Bearing- Pillow Block N/S Belt Guard Inlet Vane Assy. CW Inlet Vane Assy. CCW Crankarm Bearing, Flange Shaft, Support Ball Joint Damper Rod Mount, Actuator Plate, Linkage N/S= Not Shown on diagram. Note: Motors are listed after the fan mounting section. Drive components (Fan Sheave, Motor Sheave, V-belt(s), and Sheave Bushing(s) [if required]) are NOT listed as they are unique to the unit. If a drive component is required you may use the number from the part and cross reference it in the Daikin Applied Parts catalog, The Daikin Parts E-Commerce site, or contact Daikin Applied with model and serial number information. Inlet Vanes are normally only available on 5 x 5" FC Supply Air Fan equipped units built before These are concentric locking collar Bearings. They are direct replacements for the original setscrew locking Bearings. 3 Code 2= A, C. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 48

49 Section E- Supply Air Section Fan Assemblies 6" Airfoil Fans w/o Variable Inlet Vanes- Diagram Code 3= *E*A* 9 Motor (See Motor list at the end of the Fan mounting section.) Drive components (Fan Sheave, Motor Sheave, V-belt(s), and Sheave Bushing(s) [if required]) are NOT listed as they are unique to the unit. If a drive component is required you may use the number from the part and cross reference it in the Daikin Applied Parts Catalog, The Daikin Parts E-Commerce site, or contact Daikin Applied with model and serial number information. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 49

50 Section E- Supply Air Section Fan Assemblies 6" Airfoil Fans w/o Variable Inlet Vanes- Components Code 3= *E*A* Ref. Part Part Qty. No. Description Number 2 Wheel/Housing Assy Housing Only Motor Mount Shaft Key- Motor Sheave Bolt- Motor Mount Key- Fan Sheave Bearing Wheel Cutoff Plate Inlet Funnel Inlet Funnel N/S Belt Guard N/S= Not Shown on diagram. Notes: Motors are listed after the fan mounting section. Drive components (Fan Sheave, Motor Sheave, V-belt(s), and Sheave Bushing(s) [if required]) are NOT listed as they are unique to the unit. If a drive component is required you may use the number from the part and cross reference it in the Daikin Applied Parts catalog, The Daikin Parts E-Commerce site, or contact Daikin Applied with model and serial number information. Assy. includes Housing, Wheel, Cutoff Plate, and grease tubing. 2 Included in Wheel/Housing Assy These are concentric locking collar Bearings. They are direct replacements for the original setscrew locking Bearings. 4 Code 2= A, C. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 50

51 Section E- Supply Air Section Fan Assemblies 6" Airfoil Fans with Variable Inlet Vanes- Diagrams Code 3= *E*V* Motor (See Motor list at the end of the Fan mounting section.) Inlet Guide Vane Detail (See the following two pages.) Drive components (Fan Sheave, Motor Sheave, V-belt(s), and Sheave Bushing(s) [if required]) are NOT listed as they are unique to the unit. If a drive component is required you may use the number from the part and cross reference it in the Daikin Applied Parts catalog, The Daikin Parts E-Commerce site, or contact Daikin Applied with model and serial number information. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 5

52 Section E- Supply Air Section Fan Assemblies 6" Airfoil Fans with Variable Inlet Vanes- Diagrams, Continued Code 3= *E*V* Inlet Guide Vane Detail A A Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 52

53 Section E- Supply Air Section Fan Assemblies 6" Airfoil Fans with Variable Inlet Vanes- Components Code 3= *E*V* Ref. Part Part Qty. No. Description Number 2 Wheel/Housing Assy Housing Only Motor Mount Shaft Key- Motor Sheave Bolt- Motor Mount Key- Fan Sheave Bearing N/S Wheel Cutoff Plate Inlet Vane Assy. CW Inlet Vane Assy. CCW N/S Belt Guard Linkage Rod Assy A Bearing, Flange Ball Joint Linkage Rod Ball Joint Linkage Rod Linkage Mount N/S= Not Shown on diagram. Notes: Motors are listed after the fan mounting section. Drive components (Fan Sheave, Motor Sheave, V-belt(s), and Sheave Bushing(s) [if required]) are NOT listed as they are unique to the unit. If a drive component is required you may use the number from the part and cross reference it in the Daikin Applied Parts catalog, The Daikin Parts E-Commerce site, or contact Daikin Applied with model and serial number information. Assy. includes Housing, Wheel, Cutoff Plate, and grease tubing. 2 Included in Wheel/Housing Assy These are concentric locking collar Bearings. They are direct replacements for the original setscrew locking Bearings. 4 Code 2= A, C. 5 Included in Assy Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 53

54 Section E- Supply Air Section Supply Air Fan Mounting Diagrams Rubber-In-Shear Code 3= **** Spring Mounting Code 3= ****2, **** For additional Seismic restraint parts refer to the chart four pages after next. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 54

55 Section E- Supply Air Section Supply Air Fan Mounting 5" Forward Curved Fans- Components Code 3= *A*F*, *B*F*, *C*F*, *C*G* Rubber-In-Shear: Code 3= **** Ref. Part Part Qty. No. Description Number 09 Mount Isolator- 5x6, 5x9 Fan Code 3= *A*F, *B*F Motor H.P.= ALL Blue Isolator- 5x5 Fan w/o Inlet Vanes Code 3= *C*F Motor H.P.= thru 5 Blue Motor H.P.= 7.5 thru 0 Black Isolator- 5x5 Fan w/ Inlet Vanes Code 3= *C*G Motor H.P.= ALL Blue Screw Nut, Hex Lock Washer Screw Lock Washer Isolator- 5x6, 5x9 Fan Code 3= *A*F, *B*F Motor H.P.= ALL Blue Isolator- 5x5 Fan w/o Inlet Vanes Code 3= *C*F Motor H.P.= thru 5 Blue Motor H.P.= 7.5 thru 0 Black Isolator- 5x5 Fan w/ Inlet Vanes Code 3= *C*G Motor H.P.= thru 5 Blue Motor H.P.= 7.5 thru 0 Black Isolator- 5x6, 5x9 Fan Code 3= *A*F, *B*F Motor H.P.= ALL Blue Isolator- 5x5 Fan w/o Inlet Vanes Code 3= *C*F Motor H.P.= thru 5 Blue Motor H.P.= 7.5 thru 0 Black Isolator- 5x5 Fan w/ Inlet Vanes Code 3= *C*G Motor H.P.= ALL Blue Isolator- 5x6, 5x9 Fan Code 3= *A*F, *B*F Motor H.P.= ALL Blue Isolator- 5x5 Fan w/o Inlet Vanes Code 3= *C*F Motor H.P.= thru 5 Blue Motor H.P.= 7.5 thru 0 Black Isolator- 5x5 Fan w/ Inlet Vanes Code 3= *C*G Motor H.P.= ALL Blue Quantity listed is for ONE corner. All four corners are the same. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 55

56 Section E- Supply Air Section Supply Air Fan Mounting 5" Forward Curved Fans- Components, Continued Code 3= *A*F*, *B*F*, *C*F*, *C*G* Spring: Code 3= ****2, ****3 2 Ref. Part Part Qty. No. Description Number 09 Mount Isolator- 5x6, 5x9 Fan Code 3= *A*F*, *B*F* Motor H.P.= thru 5 Blue Motor H.P.= 7.5 Orange Isolator- 5x5 Fan w/o Inlet Vanes Code 3= *C*F* Motor H.P.= thru 3 Blue Motor H.P.= 5 thru 0 Orange Isolator- 5x5 Fan w/ Inlet Vanes Code 3= *C*G* Motor H.P.= thru 2 Blue Motor H.P.= 3 thru 0 Orange Screw Nut, Hex Lock Washer Screw Washer Lock Washer Screw Lock Washer Isolator- 5x6, 5x9 Fan Code 3= *A*F*, *B*F* Motor H.P.= thru 5 Blue Motor H.P.= 7.5 Orange Isolator- 5x5 Fan w/o Inlet Vanes Code 3= *C*F* Motor H.P.= thru 3 Blue Motor H.P.= 5 thru 0 Orange Isolator- 5x5 Fan w/ Inlet Vanes Code 3= *C*G* Motor H.P.= thru 3 Orange Motor H.P.= 5 thru 0 Brown Isolator- 5x6, 5x9 Fan Code 3= *A*F*, *B*F* Motor H.P.= thru 5 Blue Motor H.P.= 7.5 Orange Isolator- 5x5 Fan w/o Inlet Vanes Code 3= *C*F* Motor H.P.= thru 3 Blue Motor H.P.= 5 thru 0 Orange Isolator- 5x5 Fan w/ Inlet Vanes Code 3= *C*G* Motor H.P.= thru 3 Orange Motor H.P.= 5 thru 0 Brown Isolator- 5x6, 5x9 Fan Code 3= *A*F*, *B*F* Motor H.P.= thru 5 Blue Motor H.P.= 7.5 Orange Isolator- 5x5 Fan w/o Inlet Vanes Code 3= *C*F* Motor H.P.= thru 3 Blue Motor H.P.= 5 thru 0 Orange Isolator- 5x5 Fan w/ Inlet Vanes Code 3= *C*G* Motor H.P.= thru 3 Blue Motor H.P.= 5 thru 0 Orange Quantity listed is for ONE corner. All four corners are the same. 2 For a list of additional parts required for IBC seismic restraints see two pages atter next. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 56

57 Section E- Supply Air Section Supply Air Fan Mounting 6" Airfoil Fan- Components Code 3= *E*A*, *E*V* Rubber-In-Shear: Code 3= **** Ref. Part Part Qty. No. Description Number 09 Mount Isolator- 6" Fan w/o Inlet Vanes Code 3= *E*A* Motor H.P.= ALL Blue Isolator- 6" Fan w/ Inlet Vanes Code 3= *E*V* Motor H.P.= ALL Blue Screw Nut, Hex Lock Washer Screw Lock Washer Isolator- 6" Fan w/o Inlet Vanes Code 3= *E*A* Motor H.P.= thru 5 Blue Motor H.P.= 7.5 thru 0 Black Isolator- 6" Fan w/ Inlet Vanes Code 3= *E*V* Motor H.P.= thru 5 Blue Motor H.P.= 7.5 thru 0 Black Isolator- 6" Fan w/o Inlet Vanes Code 3= *E*A* Motor H.P.= ALL Blue Isolator- 6" Fan w/ Inlet Vanes Code 3= *E*V* Motor H.P.= ALL Blue Isolator- 6" Fan w/o Inlet Vanes Code 3= *E*A* Motor H.P.= ALL Blue Isolator- 6" Fan w/ Inlet Vanes Code 3= *E*V* Motor H.P.= ALL Blue Quantity listed is for ONE corner. All four corners are the same. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 57

58 Section E- Supply Air Section Supply Air Fan Mounting 6" Airfoil Fan- Components, Continued Code 3= *E*A*, *E*V* Spring: Code 3= ****2, ****3 2 Ref. Part Part Qty. No. Description Number 09 Mount Isolator- 6" Fan w/o Inlet Vanes Code 3= *E*A* Motor H.P.= thru 3 Blue Motor H.P.= 5 thru 0 Brown Isolator- 6" Fan w/ Inlet Vanes Code 3= *E*V* Motor H.P.= thru 3 Blue Motor H.P.= 5 thru 0 Brown Screw Nut, Hex Lock Washer Screw Washer Lock Washer Screw Lock Washer Isolator- 6" Fan w/o Inlet Vanes Code 3= *E*A* Motor H.P.= ALL Brown Isolator- 6" Fan w/ Inlet Vanes Code 3= *E*V* Motor H.P.= ALL Brown Isolator- 6" Fan w/o Inlet Vanes Code 3= *E*A* Motor H.P.= ALL Brown Isolator- 6" Fan w/ Inlet Vanes Code 3= *E*V* Motor H.P.= ALL Brown Isolator- 6" Fan w/o Inlet Vanes Code 3= *E*A* Motor H.P.= ALL Blue Isolator- 6" Fan w/ Inlet Vanes Code 3= *E*V* Motor H.P.= ALL Blue Quantity listed is for ONE corner. All four corners are the same. 2 For a list of additional parts required for IBC seismic restraints see the following page. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 58

59 Section E- Supply Air Section Supply Air Fan Mounting Additional Seismic Restraint Components 2 Code 3= **** Ref. Part Part Qty. No. Description Number 24 Channel Mount Angle Mount Washer- Neoprene Washer- Neoprene Spacer- Neoprene Spacer- Steel Cap Screw Lock Washer Mounting Plate Washer Washer- Locking Nut Cap Screw Washer- Locking Quantity listed is for ONE corner. All four corners are the same. 2 The above parts are required IN ADDITION to the previously listed spring isolator components. 3 Only used on 5" Fan Assemblies. Code 3- *A*F*, *B*F*, *C*F*, *C*G*. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 59

60 Section E- Supply Air Section Supply Air Fan Motors H.P. H.P. Unit ODP HiEff ODP PrEff. TEFC HiEff TEFC PrEff Code 3= Voltage C0= H 2, E C0= J C0= H 3 C0= K C04= 2.0 E**** 208/60/ F**** 208/60/ G**** 208/60/ H**** 208/60/ J**** 208/60/ K**** 208/60/ L**** 208/60/ C04= 29.0 E**** 230/60/ F**** 230/60/ G**** 230/60/ H**** 230/60/ J**** 230/60/ K**** 230/60/ L**** 230/60/ C04= 27.0 E**** 460/60/ F**** 460/60/ G**** 460/60/ H**** 460/60/ J**** 460/60/ K**** 460/60/ L**** 460/60/ C04= 37.0 E**** 575/60/ F**** 575/60/ G**** 575/60/ H**** 575/60/ J**** 575/60/ K**** 575/60/ L**** 575/60/ Note that Standard Efficiency Motors (Code 0= Y, A, G) are no longer available. Use HiEff OR PrEff Motors (Code 0= E, H, J, K) instead. 2 Code used for units built before 9/ Code used for units built after 9/ Contact Daikin Applied with model and serial number information so that the correct Motor can be identified. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 60

61 Section E- Supply Air Section Miscellaneous Electrical Components- LT0, S0, REC Ref. Part Part Qty. No. Description Number 250 Bracket Lamp Fixture- LT Bulb Electrical Box Electrical Box Cover Light Switch- S Receptacle- REC Electrical Box Mount Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 6

62 Section F- Discharge Plenum Section Notes Primary Codes that pertain: 03,, 4 Additional Codes that pertain: 07 Code 03 determines if the unit has a 33" Final Filter Section OR a 33" Blank (empty) Section after the Supply Air Section. If Code = BBBB, F*** the unit has a Final Filter Section located after the Heat Section. When a Final Filter section is provided, a Blank Section and a Discharge Plenum are required. Code 4 determines the discharge direction. Units may have bottom discharge (Code 4= G), front discharge (Code 4= H), right side discharge (Code 4= R), or left side discharge (Code 4= S). If Code 4= D, the unit has down discharge with no Discharge Plenum Section. In this case, the Discharge Opening is located in the Supply Fan Section. Code 07 indicates the type of liners and insulation specified. This affects sheet metal panel p/ns and configuration. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 62

63 Section G- Power Panel/Main Control Box Notes Primary Codes that pertain: 04, 06, 08 3, 9, 23 The Power Panel/Main Control Box, located in the Supply Air Section, has gone through three major design changes. It is important to know when the unit was built so that the correct part(s) can be identified. Refer to the Unit Model & Serial Number Nomenclature section at the beginning of this document for information on serial number date coding.. The original Power Panel/Main Control Box design was used from the start of production through 03/ A major Power Panel/Main Control Box redesign was introduced 03/05. This Control Box (Code 06= B, F) used General Electric components. This design was used exclusively until 0/ Beginning in 0/06 and used exclusively after /07, a change to Schneider Electric components was implemented (Code 06= C, G). Note that although GE and Schneider brand components are functional equivalents, they are NOT directly interchangeable. The part footprint varies and accessories such as Contactor Auxiliaries are not compatible with each other. For units built during the design transition of 0/06 thru 2/06 Contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. Code 04, determines unit voltage which affects Transformers, Contactors, Motor Protectors, Fuses, & Inverters. Code 06 determines electrical power package options and which generation of Control Box is installed for units built 999 & Later. For units built before 999, if Code 06= A the unit only has a Supply Air Fan. If Code 06= E, the unit has a Supply AND a Return Fan AND Code 9 CANNOT be YYYYY. If Code 06= Y then Code 23 must also be Y. Code 08 determines if the unit is equipped with an Inverter (VFD). If Code 08= 6A, the unit has an ABB brand Inverter on the Supply Fan. If Code 08= 7A, the unit has an ABB brand Inverter on the Supply Fan AND Return Fan. If Code 08= 6R, the unit has a Reliance brand Inverter on the Supply Fan Code. If Code 08= 7R, the unit has a Reliance brand Inverter on the Supply Fan AND Return Fan. If the unit is equipped with an Inverter it will have a Circuit Breaker (CB0, 20) NOT a total unit Disconnect (DS). The first digit of Codes 3 AND 9 determine what horsepower motor is installed. The horsepower of the Fan Motor determines the size and rating of the Fan Contactor and Motor Protector (MMP). Note that Return Fan motors are limited to a maximum of 5HP. Code 23 indicates whether or not the unit has a factory mounted Disconnect Switch, OR a Power Block. If Code 23= A the unit has one Disconnect Switch for the Supply Fan. If Code 23= E, the unit has a single Disconnect Switch for both the Supply AND Return Fan. If Code 23= P, the unit is equipped with a single Power Block. Note that for a Power Block OR Disconnect to be installed, Code 06 CANNOT be Y. Note: Temperature and Air Pressure Sensors are NOT normally factory supplied. If such parts are present they would have been special order items, or they would have been field supplied. Contact Daikin Applied with model and serial number information as well as all available vendor and p/n information to see if the required part(s) can be identified and sourced. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 63

64 Section G- Power Panel/Main Control Box Power Panel Until 3/05: Diagram FB FB9 T M22 M20 NB FB3 F OL3 OL S TB OR DS Receptacle TB2 The above drawing is to be used for representative purposes only. Components and component layout depend upon unit options selected. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 64

65 Section G- Power Panel/Main Control Box Power Panel Until 3/05: Common Components Schem. Part Part Voltage Sym. Description Number 208V 230V 380V 460V System Stop Switch S Switch- SPST Terminal Blocks TB Terminal Block- 3P 75A, 600V TB2 Terminal Block- 4P 20A Transformer- Main T Transformer Transformer Fuse Block/Fuse- Control F Fuse Holder- Control 5A, 300V Fuse- Control 5A Fuse Block/Fuse- Transformer FB3 Fuse Holder-Transformer 30A, 250V Fuse- Transformer 5A, 250V Fuse- Transformer 5A, 600V REC Receptacle Receptacle 5V Neutral Bar NB Neutral Bar Disconnect Switch DS Disconnect Switch- 3P 60A, 600V Handle/Shaft/Mechanism Assy Mechanism Only Handle Only Shaft Only " Note that the original Fuseholder is obsolete and no longer available. The old and new Fuse and Fuseholder are NOT interchangeable. If replacement of the Fuseholder is required, then also order Fuse If the unit has the original Fuseholder p/n , order Fuse This Shaft is designed to be cut to the appropriate length to accommodate various mounting positions. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 65

66 Section G- Power Panel/Main Control Box Power Panel Until 3/05: Fan Motor Contactors, Overloads, & Fusing Components.0 Horsepower Supply AND/OR Return Fan Motor- Code 3 OR 9= E**** Schem. Part Part Voltage Sym. Description Number 208V 230V 380V 460V Contactors M20, 22 Contactor- Supply (M20), Return (M22) Fan Motor Fuse Block and Fuses FB9, Fuse Block- Supply (FB9), Return (FB) Fan Motor Fuse Block- Supply (FB9), Return (FB) Fan Motor Fuse- FB9 OR FB Fuse- FB9 OR FB Overloads and Heaters OL, 3 Overload- Supply (OL), Return (OL3) Fan Motor Heater, Overload- OL OR OL3 N/S Relay, Overload Reset Horsepower Supply AND/OR Return Fan Motor- Code 3 OR 9= F**** Schem. Part Part Voltage Sym. Description Number 208V 230V 380V 460V Contactors M20, 22 Contactor- Supply (M20), Return (M22) Fan Motor Fuse Block and Fuses FB9, Fuse Block- Supply (FB9), Return (FB) Fan Motor Fuse Block- Supply (FB9), Return (FB) Fan Motor Fuse- FB9 OR FB Fuse- FB9 OR FB Overloads and Heaters OL, 3 Overload- Supply (OL), Return (OL3) Fan Motor Heater, Overload- OL OR OL3 N/S Relay, Overload Reset NOTE: Quantities Listed are PER motor. Note that there have been two different series of Overloads and Overload heaters used during the production run. When replacing an Overload OR the matching Overload Heater it is VITAL to obtain vendor p/n and amperage rating from BOTH parts. When replacing ONLY an Overload Heater, it is VERY IMPORTANT to first obtain vendor information and amperage rating from the existing Overload, Overload Heater, and Motor. It is important to obtain this information to ensure that the correct Overload Heater is selected since Overload Heaters are chosen based upon Motor amperage draw, AND Overload Heaters are NOT interchangeable between series. Also, Overload Heaters DO NOT automatically come with Overloads. OVERLOAD HEATERS MUST BE ORDERED SEPARATELY. Once vendor and amperage information is obtained, contact Daikin Applied for p/ns. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 66

67 Section G- Power Panel/Main Control Box Power Panel Until 3/05: Fan Motor Contactors, Overloads, & Fusing Components, Continued 2.0 Horsepower Supply AND/OR Return Fan Motor- Code 3 OR 9= G**** Schem. Part Part Voltage Sym. Description Number 208V 230V 380V 460V Contactors M20, 22 Contactor- Supply (M20), Return (M22) Fan Motor Fuse Block and Fuses FB9, Fuse Block- Supply (FB9), Return (FB) Fan Motor Fuse Block- Supply (FB9), Return (FB) Fan Motor Fuse- FB9 OR FB Fuse- FB9 OR FB Overloads and Heaters OL, 3 Overload- Supply (OL), Return (OL3) Fan Motor Heater, Overload- OL OR OL3 N/S Relay, Overload Reset Horsepower Supply AND/OR Return Fan Motor- Code 3 OR 9= H**** Schem. Part Part Voltage Sym. Description Number 208V 230V 380V 460V Contactors M20, 22 Contactor- Supply (M20), Return (M22) Fan Motor Fuse Block and Fuses FB9, Fuse Block- Supply (FB9), Return (FB) Fan Motor Fuse Block- Supply (FB9), Return (FB) Fan Motor Fuse- FB9 OR FB Fuse- FB9 OR FB Overloads and Heaters OL, 3 Overload- Supply (OL), Return (OL3) Fan Motor Heater, Overload- OL OR OL3 N/S Relay, Overload Reset NOTE: Quantities Listed are PER motor. Note that there have been two different series of Overloads and Overload heaters used during the production run. When replacing an Overload OR the matching Overload Heater it is VITAL to obtain vendor p/n and amperage rating from BOTH parts. When replacing ONLY an Overload Heater, it is VERY IMPORTANT to first obtain vendor information and amperage rating from the existing Overload, Overload Heater, and Motor. It is important to obtain this information to ensure that the correct Overload Heater is selected since Overload Heaters are chosen based upon Motor amperage draw, AND Overload Heaters are NOT interchangeable between series. Also, Overload Heaters DO NOT automatically come with Overloads. OVERLOAD HEATERS MUST BE ORDERED SEPARATELY. Once vendor and amperage information is obtained, contact Daikin Applied for p/ns. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 67

68 Section G- Power Panel/Main Control Box Power Panel Until 3/05: Fan Motor Contactors, Overloads, & Fusing Components, Continued 5.0 Horsepower Supply AND/OR Return Fan Motor- Code 3 OR 9= J**** Schem. Part Part Voltage Sym. Description Number 208V 230V 380V 460V Contactors M20, 22 Contactor- Supply (M20), Return (M22) Fan Motor Fuse Block and Fuses FB9, Fuse Block- Supply (FB9), Return (FB) Fan Motor Fuse Block- Supply (FB9), Return (FB) Fan Motor Fuse- FB9 OR FB Fuse- FB9 OR FB Fuse- FB9 OR FB Overloads and Heaters OL, 3 Overload- Supply (OL), Return (OL3) Fan Motor Heater, Overload- OL OR OL3 N/S Relay, Overload Reset Horsepower Supply Fan Motor- Code 3= K**** Schem. Part Part Voltage Sym. Description Number 208V 230V 380V 460V Contactors M20 Contactor- Supply Fan Motor Contactor- Supply Fan Motor Fuse Block and Fuses FB9 Fuse Block- Supply Fan Motor Fuse Block- Supply Fan Motor Fuse- FB Fuse- FB Overload and Heater OL Overload- Supply Fan Motor Heater, Overload- Supply Fan Motor N/S Relay, Overload Reset NOTE: Quantities Listed are PER motor. Note that there have been two different series of Overloads and Overload heaters used during the production run. When replacing an Overload OR the matching Overload Heater it is VITAL to obtain vendor p/n and amperage rating from BOTH parts. When replacing ONLY an Overload Heater, it is VERY IMPORTANT to first obtain vendor information and amperage rating from the existing Overload, Overload Heater, and Motor. It is important to obtain this information to ensure that the correct Overload Heater is selected since Overload Heaters are chosen based upon Motor amperage draw, AND Overload Heaters are NOT interchangeable between series. Also, Overload Heaters DO NOT automatically come with Overloads. OVERLOAD HEATERS MUST BE ORDERED SEPARATELY. Once vendor and amperage information is obtained, contact Daikin Applied for p/ns. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 68

69 Section G- Power Panel/Main Control Box Power Panel Until 3/05: Fan Motor Contactors, Overloads, & Fusing Components, Continued 0 Horsepower Supply Fan Motor- Code 3= L**** Schem. Part Part Voltage Sym. Description Number 208V 230V 380V 460V Contactors M20 Contactor- Supply Fan Motor Contactor- Supply Fan Motor Contactor- Supply Fan Motor Fuse Block and Fuses FB9 Fuse Block- Supply Fan Motor Fuse Block- Supply Fan Motor Fuse- FB Fuse- FB Fuse- FB Overload and Heater OL Overload- Supply Fan Motor Heater, Overload- Supply Fan Motor N/S Relay, Overload Reset NOTE: Quantities Listed are PER motor. Note that there have been two different series of Overloads and Overload heaters used during the production run. When replacing an Overload OR the matching Overload Heater it is VITAL to obtain vendor p/n and amperage rating from BOTH parts. When replacing ONLY an Overload Heater, it is VERY IMPORTANT to first obtain vendor information and amperage rating from the existing Overload, Overload Heater, and Motor. It is important to obtain this information to ensure that the correct Overload Heater is selected since Overload Heaters are chosen based upon Motor amperage draw, AND Overload Heaters are NOT interchangeable between series. Also, Overload Heaters DO NOT automatically come with Overloads. OVERLOAD HEATERS MUST BE ORDERED SEPARATELY. Once vendor and amperage information is obtained, contact Daikin Applied for p/ns. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 69

70 Section G- Power Panel/Main Control Box Power Panel 3/05 thru 0/06: Diagrams Power Panel/Main Control Box w/o VFD Power Panel/Main Control Box w/ VFD The above drawings are to be used for representative purposes only. Components and component layout depend upon unit options selected. For units built between 0/06 & 2/06 Contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 70

71 Section G- Power Panel/Main Control Box Power Panel 3/05 thru 0/06: Common Components Schem. Part Part Voltage Sym. Description Number 208V 230V 460V 575V S System Switch Terminal Blocks TB Terminal Block- Internal Ground Block TB2 Terminal Block- Field Ground Block Transformer- Main T Transformer- Main Control Transformer- Main Control Fuses- T FA, B Fuse- T Transformer, Primary Fuse- T Transformer, Primary Fuse- T Transformer, Primary FC Fuse- T Transformer,Secondary Fuse Puller/Cover Fuse- VFD, Return Fan FB20 Fuse Block Fuse Puller/Cover Fuse Fuse- Motor H.P.= Fuse- Motor H.P.= Fuse- Motor H.P.= Fuse- Motor H.P.= Fuse- Motor H.P.= Fuse- Motor H.P.= Fuse- Motor H.P.= Fuse- Motor H.P.= Fuse- Motor H.P.= Fuse- Motor H.P.= Fuse- Motor H.P.= Fuse- Motor H.P.= Fuse- Motor H.P.= Fuse- Motor H.P.= Fuse- Motor H.P.= Fuse- Motor H.P.= Fuse- Motor H.P.= GLG Ground Lug Power Block PB Power Block Cover- Power Block This table lists the most commonly offered Power Panel/Main Control Box components. For components not listed here contact Daikin Applied with unit model and serial number information and vendor p/n information (if available) to ensure that the required part can be identified. For units built between 0/06 & 2/06 Contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 7

72 Section G- Power Panel/Main Control Box Power Panel 3/05 thru 0/06: Disconnect Switch Voltage Ref. Schem. Part Part No. Sym. Description Number Lug DS Disconnect Switch- Main 00A Screw Handle Mechanism V 230V 460V 575V 00A is the most commonly offered Disconnect Switch size. Confirm amperage required BEFORE ordering, or contact Daikin Applied with unit model and serial number information so that the correct part(s) can be identified. For units built between 0/06 & 2/06 Contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 72

73 Section G- Power Panel/Main Control Box Power Panel 3/05 thru 0/06: Supply Fan CB0, & Return Fan CB20 Circuit Breaker Voltage Ref. Schem. Part Part No. Sym. Description Number Lug CB0 Circuit Breaker- Supply Fan CB20 Circuit Breaker- Return Fan Motor HP= thru Motor HP= Motor HP= Screw Handle Mechanism Rating Plug Motor HP= thru Motor HP= Motor HP= Motor HP= Motor HP= Motor HP= Motor HP= Motor HP= Quantity of 6 pc. if Lugs only are used. Quantity of 3pc. if Lugs and Ring Terminals are used. Ring Terminals are field supplied. 2 Quantity of 0 pc. if Lugs only are used. Quantity of 3pc. if Lugs and Ring Terminals are used. 3 Field cut shaft to required length. 4 For units built between 0/06 & 2/06 Contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. 208V 230V 460V 575V Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 73

74 Section G- Power Panel/Main Control Box Power Panel 3/05 thru 0/06: Supply MMP0 & M0 Fan Contactor, & Return MMP20 & M20 Fan Contactor- Diagram & Components 2 3A 3B 3C 3D A HP Motor- Code 3 OR 9= E**** Voltage Ref. Schem. Part Part No. Sym. Description Number M0, 20 Contactor- Supply (M0) OR Return (M20) Fan A Cover- Contactor MMP0, 20 MMP- Supply (MMP0) OR Return (MMP20) Fan MMP- Supply (MMP0) OR Return (MMP20) Fan MMP- Supply (MMP0) OR Return (MMP20) Fan A Line Shield B Link C Short Circuit Alarm D Aux. Interlock- NO/ NC V 230V 460V 575V The diagram and table show all possible parts. Not every part shown is used on every unit/voltage combination. For units built between 0/06 & 2/06 Contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 74

75 Section G- Power Panel/Main Control Box Power Panel 3/05 thru 0/06: Supply MMP0 & M0 Fan Contactor, & Return MMP20 & M20 Fan Contactor- Components.5 HP Motor- Code 3 OR 9= F**** Voltage Ref. Schem. Part Part No. Sym. Description Number M0, 20 Contactor- Supply (M0) OR Return (M20) Fan A Cover- Contactor MMP0,20 MMP- Supply (MMP0) OR Return (MMP20) Fan MMP- Supply (MMP0) OR Return (MMP20) Fan A Line Shield B Link C Short Circuit Alarm D Aux. Interlock- NO/ NC V 230V 460V 575V 2 HP Motor- Code 3 OR 9= G**** Voltage Ref. Schem. Part Part No. Sym. Description Number M0, 20 Contactor- Supply (M0) OR Return (M20) Fan A Cover- Contactor MMP0,20 MMP- Supply (MMP0) OR Return (MMP20) Fan MMP- Supply (MMP0) OR Return (MMP20) Fan MMP- Supply (MMP0) OR Return (MMP20) Fan MMP- Supply (MMP0) OR Return (MMP20) Fan A Line Shield B Link C Short Circuit Alarm D Aux. Interlock- NO/ NC V 230V 460V 575V The tables show ALL possible parts. Not every part shown is used on every unit/voltage combination. For units built between 0/06 & 2/06 Contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 75

76 Section G- Power Panel/Main Control Box Power Panel 3/05 thru 0/06: Supply MMP0 & M0 Fan Contactor, & Return MMP20 & M20 Fan Contactor- Components, Continued 3 HP Motor- Code 3 OR 9= H**** Voltage Ref. Schem. Part Part No. Sym. Description Number M0, 20 Contactor- Supply (M0) OR Return (M20) Fan A Cover- Contactor MMP0,20 MMP- Supply (MMP0) OR Return (MMP20) Fan MMP- Supply (MMP0) OR Return (MMP20) Fan MMP- Supply (MMP0) OR Return (MMP20) Fan A Line Shield B Link C Short Circuit Alarm D Aux. Interlock- NO/ NC V 230V 460V 575V 5 HP Motor- Code 3 OR 9= J**** Voltage Ref. Schem. Part Part No. Sym. Description Number M0, 20 Contactor- Supply (M0) OR Return (M20) Fan Contactor- Supply (M0) OR Return (M20) Fan Contactor- Supply (M0) OR Return (M20) Fan A Cover- Contactor Cover- Contactor Cover- Contactor MMP0,20 MMP- Supply (MMP0) OR Return (MMP20) Fan MMP- Supply (MMP0) OR Return (MMP20) Fan MMP- Supply (MMP0) OR Return (MMP20) Fan A Line Shield B Link Link C Short Circuit Alarm D Aux. Interlock- NO/ NC V 230V 460V 575V The tables show ALL possible parts. Not every part shown is used on every unit/voltage combination. For units built between 0/06 & 2/06 Contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 76

77 Section G- Power Panel/Main Control Box Power Panel 3/05 thru 0/06: Supply MMP0 & M0 Fan Contactor, & Return MMP20 & M20 Fan Contactor- Components, Continued 2 3A 3E 3B 3C A 7.5 HP Motor- Code 3= K**** Voltage Ref. Schem. Part Part No. Sym. Description Number M0 Contactor- Supply Fan Contactor- Supply Fan Contactor- Supply Fan A Cover- Contactor Cover- Contactor Cover- Contactor MMP0 MMP- Supply Fan MMP- Supply Fan MMP- Supply Fan MMP- Supply Fan A Line Shield B Link Link Link C Short Circuit Alarm E OL Circuit Alarm- Front V 230V 460V 575V The diagram and table show all possible parts. Not every part shown applies to every unit/voltage combination. For units built between 0/06 & 2/06 Contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. 2 Line Shield may have been used on early production units during this period. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 77

78 Section G- Power Panel/Main Control Box Power Panel 3/05 thru 0/06: Supply MMP0 & M0 Fan Contactor, & Return MMP20 & M20 Fan Contactor- Components, Continued 0 HP Motor- Code 3= L**** Voltage Ref. Schem. Part Part No. Sym. Description Number M0 Contactor- Supply Fan Contactor- Supply Fan Contactor- Supply Fan A Cover- Contactor Cover- Contactor Cover- Contactor MMP0 MMP- Supply Fan MMP- Supply Fan MMP- Supply Fan A Line Shield B Link Link C Short Circuit Alarm E OL Circuit Alarm- Front V 230V 460V 575V The table shows all possible parts. Not every part shown applies to every unit/voltage combination. For units built between 0/06 & 2/06 Contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. 2 Line Shield may have been used on early production units during this period. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 78

79 Section G- Power Panel/Main Control Box Power Panel /07 & Later: Diagrams Power Panel/Main Control Box w/o VFD Power Panel/Main Control Box w/ VFD The above drawings are to be used for representative purposes only. Components and component layout depend upon unit options selected. For units built between 0/06 & 2/06 Contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 79

80 Section G- Power Panel/Main Control Box Power Panel /07 & Later: Control Box Component Label Diagram Note that starting in late 200, all units will have a label similar to the one shown above pasted to the inside of the Control Box door. This label contains schematic designators, part descriptions, and Daikin Applied part numbers. The label shown above is for representative purposes only. Actual part numbers will vary depending upon unit options and features. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 80

81 Section G- Power Panel/Main Control Box Power Panel /07 & Later: Components Schem. Part Part Voltage Sym. Description Number 208V 230V 460V 575V S System Switch Terminal Blocks TB Terminal Block- Internal Ground Block TB2 Terminal Block- Field Ground Block Transformer- Main T Transformer- Main Control Transformer- Main Control Fuses- T FA, B Fuse- T Transformer, Primary Fuse- T Transformer, Primary Fuse- T Transformer, Primary FC Fuse- T Transformer,Secondary Fuse Puller/Cover Fuse- VFD, Return Fan FB20 Fuse Block Fuse Puller/Cover Fuse Fuse- Motor H.P.= Fuse- Motor H.P.= Fuse- Motor H.P.= Fuse- Motor H.P.= Fuse- Motor H.P.= Fuse- Motor H.P.= Fuse- Motor H.P.= Fuse- Motor H.P.= Fuse- Motor H.P.= Fuse- Motor H.P.= Fuse- Motor H.P.= Fuse- Motor H.P.= Fuse- Motor H.P.= Fuse- Motor H.P.= Fuse- Motor H.P.= Fuse- Motor H.P.= Fuse- Motor H.P.= GLG Ground Lug Power Block PB Power Block Cover- Power Block This table lists the most commonly offered Power Panel/Main Control Box components. For components not listed here contact Daikin Applied with unit model and serial number information and vendor p/n information (if available) to ensure that the required part(s) can be identified. For units built between 0/06 & 2/06 Contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 8

82 Section G- Power Panel/Main Control Box Power Panel /07 & Later: Disconnect Switch- Diagram & Components 2 4 Voltage Ref. Schem. Part Part No. Sym. Description Number Lug DS Disconnect Switch- Main 2 00A Handle/Mechanism V 230V 460V 575V For units built between 0/06 & 2/06 Contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. 2 00A is the most commonly offered Disconnect Switch size. Confirm amperage required BEFORE ordering, or contact Daikin Applied with unit model and serial number information so that the correct part(s) can be identified. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 82

83 Section G- Power Panel/Main Control Box Power Panel /07 & Later: Supply Fan CB0, & Return Fan CB20 Circuit Breaker- Diagram & Components 2 4 Circuit Breaker 208V Ref. Schem. Part Part Voltage No. Sym. Description Number 208V 2 CB0 Circuit Breaker- Supply Fan CB20 Circuit Breaker- Return Fan Motor HP= thru 3 5A Motor HP= 5 25A Motor HP= 7.5, PremEff, Code 0= J, K 30A Motor HP= 7.5, HiEff, Code 0= E, H 35A Motor HP= 0, PremEff, Code 0= J, K 40A Motor HP= 0, HiEff, Code 0= E, H 45A Power Block, 3P 2 75A, 600V The diagram and table show all possible parts. Not every part shown is used on every unit/voltage combination. For units built between 0/06 & 2/06 Contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. 2 The Power Block is used when mounting field installed Inverters Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 83

84 Section G- Power Panel/Main Control Box Power Panel /07 & Later: Supply Fan CB0, & Return Fan CB20 Circuit Breaker- Components Circuit Breaker 230V Ref. Schem. Part Part Voltage No. Sym. Description Number 230V 2 CB0 Circuit Breaker- Supply Fan CB20 Circuit Breaker- Return Fan Motor HP= thru 3 5A Motor HP= 5 20A Motor HP= A Motor HP= 0 35A Power Block, 3P 2 75A, 600V Circuit Breaker 460V Ref. Schem. Part Part Voltage No. Sym. Description Number 460V 2 CB0 Circuit Breaker- Supply Fan CB20 Circuit Breaker- Return Fan Motor HP= thru 7.5 5A Motor HP= 0 20A Power Block, 3P 2 75A, 600V Circuit Breaker 575V Ref. Schem. Part Part Voltage No. Sym. Description Number 575V 2 CB0 Circuit Breaker- Supply Fan CB20 Circuit Breaker- Return Fan Motor HP= ALL 5A Power Block, 3P 2 75A, 600V The table shows all possible parts. Not every part shown is used on every unit/voltage combination. For units built between 0/06 & 2/06 Contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. 2 The Power Block is used when mounting field installed Inverters Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 84

85 Section G- Power Panel/Main Control Box Power Panel /07 & Later: Supply MMP0 & M0 Fan Contactor, & Return MMP20 & M20 Fan Contactor- Diagram & Components 2 3G 3B 3F HP Motor- Code 3 OR 9= E**** Voltage Ref. Schem. Part Part No. Sym. Description Number M0, 20 Contactor- Supply (M0) OR Return (M20) Fan MMP0,20 MMP- Supply (MMP0) OR Return (MMP20) Fan MMP- Supply (MMP0) OR Return (MMP20) Fan MMP- Supply (MMP0) OR Return (MMP20) Fan B Link F Spacer G Auxilary- NO/ NC V 230V 460V 575V.5 HP Motor- Code 3 OR 9= F**** Voltage Ref. Schem. Part Part No. Sym. Description Number M0, 20 Contactor- Supply (M0) OR Return (M20) Fan MMP0,20 MMP- Supply (MMP0) OR Return (MMP20) Fan MMP- Supply (MMP0) OR Return (MMP20) Fan B Link F Spacer G Auxilary- NO/ NC V 230V 460V 575V The diagram and table show all possible parts. Not every part shown is used on every unit/voltage combination. Note that MMPs are only used when no Inverter is supplied. For units built between 0/06 & 2/06 Contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 85

86 Section G- Power Panel/Main Control Box Power Panel /07 & Later: Supply MMP0 & M0 Fan Contactor, & Return MMP20 & M20 Fan Contactor- Components, Continued 2 HP Motor- Code 3 OR 9= G**** Voltage Ref. Schem. Part Part No. Sym. Description Number M0, 20 Contactor- Supply (M0) OR Return (M20) Fan MMP0,20 MMP- Supply (MMP0) OR Return (MMP20) Fan MMP- Supply (MMP0) OR Return (MMP20) Fan MMP- Supply (MMP0) OR Return (MMP20) Fan MMP- Supply (MMP0) OR Return (MMP20) Fan B Link F Spacer G Auxilary- NO/ NC V 230V 460V 575V 3 HP Motor- Code 3 OR 9= H**** Voltage Ref. Schem. Part Part No. Sym. Description Number M0, 20 Contactor- Supply (M0) OR Return (M20) Fan Contactor- Supply (M0) OR Return (M20) Fan MMP0,20 MMP- Supply (MMP0) OR Return (MMP20) Fan MMP- Supply (MMP0) OR Return (MMP20) Fan MMP- Supply (MMP0) OR Return (MMP20) Fan MMP- Supply (MMP0) OR Return (MMP20) Fan B Link F Spacer G Auxilary- NO/ NC V 230V 460V 575V 5 HP Motor- Code 3 OR 9= J**** Voltage Ref. Schem. Part Part No. Sym. Description Number M0, 20 Contactor- Supply (M0) OR Return (M20) Fan Contactor- Supply (M0) OR Return (M20) Fan MMP0,20 MMP- Supply (MMP0) OR Return (MMP20) Fan MMP- Supply (MMP0) OR Return (MMP20) Fan MMP- Supply (MMP0) OR Return (MMP20) Fan MMP- Supply (MMP0) OR Return (MMP20) Fan B Link F Spacer G Auxilary- NO/ NC V 230V 460V 575V The tables show ALL possible parts. Not every part shown is used on every unit/voltage combination. Note that MMPs are only used when no Inverter is supplied. For units built between 0/06 & 2/06 Contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 86

87 Section G- Power Panel/Main Control Box Power Panel /07 & Later: Supply MMP0 & M0 Fan Contactor, & Return MMP20 & M20 Fan Contactor- Components, Continued 7.5 HP Motor- Code 3= K**** Voltage Ref. Schem. Part Part No. Sym. Description Number M0 Contactor- Supply Fan Contactor- Supply Fan Contactor- Supply Fan MMP0 MMP- Supply Fan MMP- Supply Fan MMP- Supply Fan B Link F Spacer G Auxilary- NO/ NC V 230V 460V 575V 0 HP Motor- Code 3= L**** Voltage Ref. Schem. Part Part No. Sym. Description Number M0 Contactor- Supply Fan Contactor- Supply Fan Contactor- Supply Fan MMP0 MMP- Supply Fan MMP- Supply Fan MMP- Supply Fan B Link F Spacer G Auxilary- NO/ NC V 230V 460V 575V The tables show ALL possible parts. Not every part shown is used on every unit/voltage combination. Note that MMPs are only used when no Inverter is supplied. For units built between 0/06 & 2/06 Contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 87

88 Section G- Power Panel/Main Control Box Inverters (VFDs) Code 08= *A: ABB Model ACH550 (8/04 & Later) 2 Motor Horsepower Part Number Model ACH40 Inverters used until 8/04 have been discontinued and are no longer available. Replace with the comparable Model ACH550 p/n shown above. Note that repair parts for Model ACH40 Inverters are also no longer available. The Keypad Display for Model ACH550 Inverters is p/n V 230V 460V 208V 230V 460V 208V 230V 460V 208V 230V 460V 208V 230V 460V 208V 230V 460V 208V 230V 460V Code 08= *R: Reliance Model VTAC9 3 Motor Horsepower Part Number Confirm availability before ordering. 208V 230V 460V 208V 230V 460V 208V 230V 460V 208V 230V 460V 208V 230V 460V 208V 230V 460V 208V 230V 460V Quantity listed is for the Supply Air Fan only. If the unit has a Return Fan Inverter (Code 08= 7*) the unit will have a quantity of two Inverters. Note that Inverters are not available for 575V units (Code 04= 37). Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 88

89 Section H- Miscellaneous Cabinet Components Notes, Door Latches, Hinge, & Holding Rod Primary Codes that pertain: None These Door Latching Assemblies are used on Standard Unit Section Access Doors. When replacing a Latch Assembly, first determine the handing of the door. Door handing is dependent upon the door's location on the unit. For Handing identification, refer to the drawings below. If unable to determine the hand of the door, contact Daikin Applied with model and serial information AND the location of the door. Door Latch Assembly Left-hand Side Door Latch Assembly Right-hand Side Door Holding Rod 44 A Ref. Part Part No. Description Number 0 Door Latch Assy. Right Hand- 02/02 & Earlier Door Latch Assy. Left Hand- 02/02 & Earlier Door Latch Assy. Right Hand- 2/02 & Later Door Latch Assy. Left Hand- 2/02 & Later Rivet Door Latch Screw N/S Hinge, Door Door Holding Rod 33 Section Dimension A = Door Holding Rod 48 Section Dimension A = Rooftop Units: RDS 708 Vintage "B" Rev. F 03/8 RPL / Page 89

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage D. LML, LSB, MMM, MSB Vintage E

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage D. LML, LSB, MMM, MSB Vintage E Replacement Parts List No. 046902100 Revision D 01/2015 McQuay Central Station Air Handler LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL 137-172 Vintage D LML, LSB, MMM, MSB 137-172 Vintage E Last Manufactured:

More information

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage C. Last Manufactured: 1984

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage C. Last Manufactured: 1984 Replacement Parts List No. 055222700 Revision D 0/205 McQuay Central Station Air Handler LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL 37-72 Vintage C Last Manufactured: 984 To find your Daikin Applied parts

More information

McQuay. Central Station Air Handlers Low Pressure. LHD, LYF, LSL, LML, LWL Vintage C. LML, LSB Vintage E. Last Manufactured: 1999

McQuay. Central Station Air Handlers Low Pressure. LHD, LYF, LSL, LML, LWL Vintage C. LML, LSB Vintage E. Last Manufactured: 1999 Replacement Parts List No. 055222600 Revision F 11/2011 McQuay Central Station Air Handlers Low Pressure LHD, LYF, LSL, LML, LWL 103-228 Vintage C LML, LSB 106-111 Vintage E Last Manufactured: 1999 To

More information

McQuay Central Station Air Handler Medium Pressure MSL

McQuay Central Station Air Handler Medium Pressure MSL Replacement Parts List No. 55223700 Revision B 09/2016 McQuay Central Station Air Handler Medium Pressure MSL 190 Vintage C Last Manufactured: 1998 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Self-Contained Variable and Constant Air Volume. SWP Vintage F. Replacement Parts List No Revision G 04/2018

McQuay. Self-Contained Variable and Constant Air Volume. SWP Vintage F. Replacement Parts List No Revision G 04/2018 Replacement Parts List No. 700006000 Revision G 04/208 McQuay Self-Contained Variable and Constant Air Volume SWP 08-095 Vintage F To find your Daikin Applied parts distributor, call -800-377-2787 or visit

More information

Daikin McQuay. Large Capacity Fan Coil Belt Drive. HCBB, HHBB Design 1. Replacement Parts List No Revision E 03/2018

Daikin McQuay. Large Capacity Fan Coil Belt Drive. HCBB, HHBB Design 1. Replacement Parts List No Revision E 03/2018 Replacement s List No. 700024000 Revision E 03/2018 Daikin McQuay Large Capacity Fan Coil Belt Drive HCBB, HHBB 08-30 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit

More information

McQuay. HiLine Fan Coil. HSB Vintage B. Last Manufactured: Replacement Parts List No Revision C 09/2016

McQuay. HiLine Fan Coil. HSB Vintage B. Last Manufactured: Replacement Parts List No Revision C 09/2016 Replacement Parts List No. 055211200 Revision C 09/2016 McQuay HiLine Fan Coil HSB 030-120 Vintage B Last Manufactured: 1990 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit

More information

Daikin McQuay. Roofpak Draw Thru/Blow Thru Air Handler Large Cabinet. RAH 077 Vintage C. Replacement Parts List No Revision AB 03/2018

Daikin McQuay. Roofpak Draw Thru/Blow Thru Air Handler Large Cabinet. RAH 077 Vintage C. Replacement Parts List No Revision AB 03/2018 Replacement Parts List No. 70000800 Revision AB 0/08 Daikin McQuay Roofpak Draw Thru/Blow Thru Air Handler Large Cabinet RAH 077 Vintage C To find your Daikin Applied parts distributor, call -800-77-787

More information

Daikin McQuay. Roofpak Condensing Unit Small Cabinet, Standalone Standard & Digital Compressor Models

Daikin McQuay. Roofpak Condensing Unit Small Cabinet, Standalone Standard & Digital Compressor Models Replacement Parts List No. 70009700 Revision M 0/08 Daikin McQuay Roofpak Condensing Unit Small Cabinet, Standalone Standard & Digital Compressor Models RCS 05-040 Vintage D Code = A, A, YA Code 44= R,

More information

Daikin. PreciseLine Horizontal Large Capacity Blower Coil. BCHD Design 1. Replacement Parts List No Revision A 03/2019

Daikin. PreciseLine Horizontal Large Capacity Blower Coil. BCHD Design 1. Replacement Parts List No Revision A 03/2019 Replacement Parts List No. 700053700 Revision A 03/2019 Daikin PreciseLine Horizontal Large Capacity Blower Coil BCHD 030-050 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision B 03/2016

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision B 03/2016 Replacement s List 70002400 Revision B 03/206 Daikin McQuay Large Capacity Fan Coil Direct Drive HCDB, HHDB 06-20 Design To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com

More information

Daikin McQuay. Destiny Indoor Air Handler. LAH Vintage A. Replacement Parts List No Revision T 10/2017

Daikin McQuay. Destiny Indoor Air Handler. LAH Vintage A. Replacement Parts List No Revision T 10/2017 Replacement Parts List No. 700004800 Revision T 10/2017 Daikin McQuay Destiny Indoor Air Handler LAH 002-030 Vintage A To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.daikinapplied.com

More information

McQuay. Thinline Vertical Fan Coil Floor Mounted. TSF Vintage G. Last Manufactured: 1997

McQuay. Thinline Vertical Fan Coil Floor Mounted. TSF Vintage G. Last Manufactured: 1997 Replacement Parts List No. 057117400 Revision F 08/2016 McQuay Thinline Vertical Fan Coil Floor Mounted TSF 021-121 Vintage G Last Manufactured: 1997 To find your Daikin Applied parts distributor, call

More information

McQuay Climate Control. Horizontal Water Source Heat Pump. CC, CG, CW Vintage C, D. Last Manufactured: 1986

McQuay Climate Control. Horizontal Water Source Heat Pump. CC, CG, CW Vintage C, D. Last Manufactured: 1986 Replacement Parts List No. 05520400 Revision D 01/2017 McQuay Climate Control Horizontal Water Source Heat Pump CC, CG, CW 0750-1000 Vintage C, D Last Manufactured: 1986 To find your Daikin Applied parts

More information

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision C 03/2018

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision C 03/2018 Replacement s List 700024100 Revision C 03/2018 Daikin McQuay Large Capacity Fan Coil Direct Drive HCDB, HHDB 06-20 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit

More information

Daikin McQuay. Maverick II Commercial Packaged Rooftop Cooling and Heating. MPS Vintage E

Daikin McQuay. Maverick II Commercial Packaged Rooftop Cooling and Heating. MPS Vintage E Replacement Parts List No. 70005800 Revision T /07 Daikin McQuay Maverick II Commercial Packaged Rooftop Cooling and Heating MPS 06-075 Vintage E To find your Daikin Applied parts distributor, call -800-377-787

More information

Roofpak Applied Rooftop Units

Roofpak Applied Rooftop Units Replacement Parts List No. 70005000 Revision P 08/2 Roofpak Applied Rooftop Units RPS, RFS, RCS Sizes: 05-042 Vintage D R40a To find your Daikin McQuay parts distributor, call -800-377-2787 or visit www.daikinmcquay.com

More information

Daikin. Roofpak Applied Rooftop Units Inverter Compressor Models. RPS Vintage D Code 44= V, W

Daikin. Roofpak Applied Rooftop Units Inverter Compressor Models. RPS Vintage D Code 44= V, W Replacement Parts List No. 70005200 Revision J 05/208 Daikin Roofpak Applied Rooftop Units Inverter Compressor Models RPS 06-042 Vintage D Code 44= V, W To find your Daikin Applied parts distributor, call

More information

Daikin McQuay. Roofpak Condensing Unit Medium Cabinet, Standalone Standard & Digital Compressor Models

Daikin McQuay. Roofpak Condensing Unit Medium Cabinet, Standalone Standard & Digital Compressor Models Replacement Parts List No. 7000600 Revision S 0/08 Daikin McQuay Roofpak Condensing Unit Medium Cabinet, Standalone Standard & Digital Compressor Models RCS 045-075 Tons Vintage D Code = A, A, YA Unit

More information

McQuay. Cabinet Unit Heater. CHB, CHF Vintage A. FCHB, FCHF Design A (1) Last Manufactured: 2010

McQuay. Cabinet Unit Heater. CHB, CHF Vintage A. FCHB, FCHF Design A (1) Last Manufactured: 2010 Replacement Parts List No. 055211700 Revision G 05/2017 McQuay Cabinet Unit Heater CHB, CHF 003-015 Vintage A FCHB, FCHF 03-15 Design A (1) Last Manufactured: 2010 To find your Daikin Applied parts distributor,

More information

McQuay Package System MPS062E, MPS070E, MPS075E PL

McQuay Package System MPS062E, MPS070E, MPS075E PL McQuay Package System 062E, 070E, 075E PL-1003-8 062E / 070E / 075E 1 062E / 070E / 075E 2 062E / 070E / 075E 3 062E / 070E / 075E 4 062E / 070E / 075E 5 062E / 070E / 075E 6 062E / 070E / 075E 7 8 Section

More information

McQuay Climate Control. Commercial Unitary Rooftop. CUR Vintage F. Last Manufactured: 1996

McQuay Climate Control. Commercial Unitary Rooftop. CUR Vintage F. Last Manufactured: 1996 Replacement s List No. 055236800 Revision C 11/2016 McQuay Climate Control Commercial Unitary Rooftop CUR 075-150 Vintage F Last Manufactured: 1996 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Seasonmaker Horizontal Fan Coil. TSC Vintage G. Last Manufactured: Replacement Parts List No Revision C 08/2016

McQuay. Seasonmaker Horizontal Fan Coil. TSC Vintage G. Last Manufactured: Replacement Parts List No Revision C 08/2016 Replacement Parts List 057117500 Revision C 08/2016 McQuay Seasonmaker Horizontal Fan Coil TSC 021-121 Vintage G Last Manufactured: 1997 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 030, 036, 042 Design 1. Replacement Parts List No Revision B 10/2016

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 030, 036, 042 Design 1. Replacement Parts List No Revision B 10/2016 Replacement Parts List No. 700011300 Revision B 10/2016 McQuay Ceiling Mounted Water Source Heat Pump WCRH, WCRW 030, 036, 042 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Air-Cooled Global Reciprocating Condensing Unit. ACR Vintage A. Last Manufactured: 2003

McQuay. Air-Cooled Global Reciprocating Condensing Unit. ACR Vintage A. Last Manufactured: 2003 Replacement Parts List No. 110504800 Revision G 04/2016 McQuay Air-Cooled Global Reciprocating Condensing Unit ACR 060-120 Vintage A Last Manufactured: 2003 To find your Daikin Applied parts distributor,

More information

Roofpak Applied Rooftop Units

Roofpak Applied Rooftop Units Replacement Parts List No. 70003700 Revision U 07/2 Roofpak Applied Rooftop Units RPS, RDT, RFS, RCS Sizes 045-079 Tons Vintage D R40a To find your Daikin McQuay Parts distributor, call -800-377-2787 or

More information

McQuay. SeasonMaster Central Station Air Handler. HSH, HMH, HWL Vintage B Vintage C. Last Manufactured: 1984

McQuay. SeasonMaster Central Station Air Handler. HSH, HMH, HWL Vintage B Vintage C. Last Manufactured: 1984 Replacement Parts List No. 055223300 Revision B 06/2018 McQuay SeasonMaster Central Station Air Handler HSH, HMH, HWL 137-164 Vintage B 117-128 Vintage C Last Manufactured: 1984 To find your Daikin Applied

More information

McQuay. Incremental. PFEC, PFES, PFHC, PFHS Suite II, 2 Motor 007, 009, 012, 015 Designs A(1), B(2) Last Manufactured: 2001

McQuay. Incremental. PFEC, PFES, PFHC, PFHS Suite II, 2 Motor 007, 009, 012, 015 Designs A(1), B(2) Last Manufactured: 2001 Replacement Parts List 110505300 Revision G 07/2016 McQuay Incremental PFEC, PFES, PFHC, PFHS Suite II, 2 Motor 007, 009, 012, 015 Designs A(1), B(2) Last Manufactured: 2001 To find your Daikin Applied

More information

McQuay. Roofpak Applied Rooftop Units. RPS/RFS/RCS Vintage C. Replacement Parts List No Revision BD 04/2018

McQuay. Roofpak Applied Rooftop Units. RPS/RFS/RCS Vintage C. Replacement Parts List No Revision BD 04/2018 Replacement Parts List No. 0577700 Revision BD 04/08 McQuay Roofpak Applied Rooftop Units RPS/RFS/RCS 05-040 Vintage C To find your Daikin Applied parts distributor, call -800-377-787 or visit www.daikinapplied.com

More information

McQuay Climate Control. Water Source Heat Pump. CC, CG Vintage E, F, G. Last Manufactured: 1986

McQuay Climate Control. Water Source Heat Pump. CC, CG Vintage E, F, G. Last Manufactured: 1986 Replacement Parts List No. 110508600 Revision C 12/2008 McQuay Climate Control Water Source Heat Pump CC, CG 750-1000 Vintage E, F, G Last Manufactured: 1986 To find your Daikin Applied parts distributor,

More information

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 048, 060, 070 Design 1. Replacement Parts List No Revision C 10/2016

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 048, 060, 070 Design 1. Replacement Parts List No Revision C 10/2016 Replacement Parts List No. 700011400 Revision C 10/2016 McQuay Ceiling Mounted Water Source Heat Pump WCRH, WCRW 048, 060, 070 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin. Roofpak Applied Rooftop Units Inverter Compressor Models. RPS, RDT Tons Vintage D Code 44= V, W

Daikin. Roofpak Applied Rooftop Units Inverter Compressor Models. RPS, RDT Tons Vintage D Code 44= V, W Replacement Parts List No. 70005300 Revision H 0/207 Daikin Roofpak Applied Rooftop Units Inverter Compressor Models RPS, RDT 045-074 Tons Vintage D Code 44= V, W To find your Daikin Applied parts distributor,

More information

Complete HVAC Capability

Complete HVAC Capability Air Handling Units Brochure 1110 January 2006 Complete HVAC Capability MEA Horizontal Draw-Thru to Size 65 Vertical Draw-Thru to Size 50 1000 to 60,000 CFM Forward Curved or Airfoil Wheels Inlet Vane Option

More information

McQuay Climate Control Singer

McQuay Climate Control Singer Replacement Parts List No. 55205400 Rev. B 09/2015 McQuay Climate Control Singer Large Vertical Water Source Heat Pump LGP, LHP, LWP 18, 22 Vintage A Last Manufactured: 1989 To find your Daikin Applied

More information

Daikin McQuay. Roofpak Applied Rooftop Units Standard Compressor Models. RPS, RFS, RDT, RCS Tons Vintage D Unit Model Code 44= R, S

Daikin McQuay. Roofpak Applied Rooftop Units Standard Compressor Models. RPS, RFS, RDT, RCS Tons Vintage D Unit Model Code 44= R, S Replacement Parts List No. 70000800 Revision AR 05/08 Daikin McQuay Roofpak Applied Rooftop Units Standard Compressor Models RPS, RFS, RDT, RCS 080-40 Tons Vintage D Unit Model Code 44= R, S To find your

More information

McQuay. Large Capacity Fan Coil Belt Drive. SCB, SHB Vintage B. FCZA, FCZC, FCZH, FHZA, FHZC, FHZH S08 - S30 Design A (1)

McQuay. Large Capacity Fan Coil Belt Drive. SCB, SHB Vintage B. FCZA, FCZC, FCZH, FHZA, FHZC, FHZH S08 - S30 Design A (1) Replacement Parts List No. 055236400 Revision U 0/208 McQuay Large Capacity Fan Coil Belt Drive SCB, SHB 08-30 Vintage B FCZA, FCZC, FCZH, FHZA, FHZC, FHZH S08 - S30 Design A () To find your Daikin Applied

More information

McQuay. Water Source Heat Pump Replacement Chassis. VF Vintage H. Last Manufactured: 1992

McQuay. Water Source Heat Pump Replacement Chassis. VF Vintage H. Last Manufactured: 1992 Replacement Parts List No. 110502800 Revision A 02/2006 McQuay Water Source Heat Pump Replacement Chassis VF 100-330 Vintage H Last Manufactured: 1992 To find your Daikin Applied parts distributor, call

More information

McQuay. Ceiling Concealed Water Source Heat Pump. CCH, CCG, CCW 015, 019 Vintage A. Last Manufactured: 1995

McQuay. Ceiling Concealed Water Source Heat Pump. CCH, CCG, CCW 015, 019 Vintage A. Last Manufactured: 1995 Replacement Parts List No. 55235700 Revision C 08/2017 McQuay Ceiling Concealed Water Source Heat Pump CCH, CCG, CCW 015, 019 Vintage A Last Manufactured: 1995 To find your Daikin Applied parts distributor,

More information

Daikin McQuay. Self-Contained Variable and Constant Air Volume. SWP Vintage H. Replacement Parts List No Revision I 11/2017

Daikin McQuay. Self-Contained Variable and Constant Air Volume. SWP Vintage H. Replacement Parts List No Revision I 11/2017 Replacement Parts List No. 7000900 Revision I /207 Daikin McQuay Self-Contained Variable and Constant Air Volume SWP 02-30 Vintage H To find your Daikin Applied parts distributor, call -800-377-2787 or

More information

McQuay Climate Control Singer. Rooftop Unit. ER, R 080 Vintage A, B, C, D. Last Manufactured: 1996

McQuay Climate Control Singer. Rooftop Unit. ER, R 080 Vintage A, B, C, D. Last Manufactured: 1996 Replacement Parts List No. 779200300 Revision C 04/2011 McQuay Climate Control Singer Rooftop Unit ER, R 080 Vintage A, B, C, D Last Manufactured: 1996 To find your Daikin Applied parts distributor, call

More information

Daikin McQuay. Roofpak Applied Rooftop Units Standard & Digital Scroll Compressor Models. RPS, RFS, RCS Vintage D Code 44= R, D

Daikin McQuay. Roofpak Applied Rooftop Units Standard & Digital Scroll Compressor Models. RPS, RFS, RCS Vintage D Code 44= R, D Replacement Parts List No. 70005000 Revision AN 05/08 Daikin McQuay Roofpak Applied Rooftop Units Standard & Digital Scroll Compressor Models RPS, RFS, RCS 05-04 Vintage D Code 44= R, D To find your Daikin

More information

McQuay Air-Cooled Reciprocating Chiller ALR

McQuay Air-Cooled Reciprocating Chiller ALR Replacement Parts List No. 057115200 Revision S 07/2015 McQuay Air-Cooled Reciprocating Chiller ALR Sizes 010-185 Vintage D Last Manufactured: 2000 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage B. FSCD, FSHD Design A (1)

McQuay. Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage B. FSCD, FSHD Design A (1) Replacement Parts List No. 055236500 Revision J 07/207 McQuay Large Capacity Fan Coil Direct Drive SCD, SHD 06-20 Vintage B FSCD, FSHD 06-20 Design A () To find your Daikin Applied parts distributor, call

More information

Daikin McQuay. VAV Air Terminal Unit MQ FCI6, FVI5, THI5. Replacement Parts List No Revision J 07/2017

Daikin McQuay. VAV Air Terminal Unit MQ FCI6, FVI5, THI5. Replacement Parts List No Revision J 07/2017 Replacement Parts List No. 700020000 Revision J 07/2017 Daikin McQuay VAV Air Terminal Unit MQ FCI6, FVI5, THI5 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.daikinapplied.com

More information

Daikin McQuay. Roofpak Applied Rooftop Units Standard & Digital Scroll Compressor Models

Daikin McQuay. Roofpak Applied Rooftop Units Standard & Digital Scroll Compressor Models Replacement Parts List No. 70003700 Revision AR 05/08 Daikin McQuay Roofpak Applied Rooftop Units Standard & Digital Scroll Compressor Models RPS, RDT, RFS, RCS 045-079 Tons Vintage D Unit Model Code 44=

More information

McQuay. Seasonmaker Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage A. Last Manufactured: 1986

McQuay. Seasonmaker Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage A. Last Manufactured: 1986 Replacement Parts List No. 47650300 Rev. A 09/205 McQuay Seasonmaker Large Capacity Fan Coil Direct Drive SCD, SHD 06-20 Vintage A Last Manufactured: 986 To find your Daikin Applied parts distributor,

More information

McQuay. Roofpak Applied Rooftop Units. RPS, RCS, RFS Vintage B. RBS, RDS, RHS, RWS Vintage B

McQuay. Roofpak Applied Rooftop Units. RPS, RCS, RFS Vintage B. RBS, RDS, RHS, RWS Vintage B Replacement Parts List No. 047654300 Revision AC 06/2016 McQuay Roofpak Applied Rooftop Units RPS, RCS, RFS 018-100 Vintage B RBS, RDS, RHS, RWS 800-808 Vintage B To find your Daikin Applied parts distributor,

More information

McQuay. Enfinity Ceiling Mounted Water Source Heat Pump. WCCH, WCCW 019, 024 Design 1. Last Manufactured: 2008

McQuay. Enfinity Ceiling Mounted Water Source Heat Pump. WCCH, WCCW 019, 024 Design 1. Last Manufactured: 2008 Replacement Parts List No. 700013300 Revision A 05/2017 McQuay Enfinity Ceiling Mounted Water Source Heat Pump WCCH, WCCW 019, 024 Design 1 Last Manufactured: 2008 To find your Daikin Applied parts distributor,

More information

McQuay. Console Water Source Heat Pump. European Unit WWME, WWMJ, WWMK, WWML Designs A, B (1, 2) Last Manufactured: 2004

McQuay. Console Water Source Heat Pump. European Unit WWME, WWMJ, WWMK, WWML Designs A, B (1, 2) Last Manufactured: 2004 Replacement Parts List 110502500 Revision C 02/2017 McQuay Console Water Source Heat Pump European Unit WWME, WWMJ, WWMK, WWML 007-015 Designs A, B (1, 2) Last Manufactured: 2004 To find your Daikin Applied

More information

McQuay. Seasonpak Reciprocating Chiller. WHR Vintage C. Last Manufactured: Replacement Parts List No Revision I 05/2016

McQuay. Seasonpak Reciprocating Chiller. WHR Vintage C. Last Manufactured: Replacement Parts List No Revision I 05/2016 Replacement Parts List No. 055224300 Revision I 05/2016 McQuay Seasonpak Reciprocating Chiller WHR 008-120 Vintage C Last Manufactured: 1998 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 007, 009, 012 Design 4. Replacement Parts List No Revision L 02/2018

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 007, 009, 012 Design 4. Replacement Parts List No Revision L 02/2018 Replacement Parts List No. 700016100 Revision L 02/2018 Daikin McQuay Enfinity Horizontal Water Source Heat Pump WCCH, WCCW 007, 009, 012 Design 4 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Evaporative Condenser Cooled Chiller. EGR Vintage A. Last Manufactured: Replacement Parts List No Revision B 07/2010

McQuay. Evaporative Condenser Cooled Chiller. EGR Vintage A. Last Manufactured: Replacement Parts List No Revision B 07/2010 Replacement Parts List No. 700015100 Revision B 07/2010 McQuay Evaporative Condenser Cooled Chiller EGR 060-240 Vintage A Last Manufactured: 2004 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin. Rebel Commercial Packaged Rooftop Cooling & Heating. DPS Vintage A. Replacement Parts List No Revision T 09/2018

Daikin. Rebel Commercial Packaged Rooftop Cooling & Heating. DPS Vintage A. Replacement Parts List No Revision T 09/2018 Replacement Parts List No. 70005400 Revision T 09/208 Daikin Rebel Commercial Packaged Rooftop Cooling & Heating DPS 06-028 Vintage A To find your Daikin Applied parts distributor, call -800-377-2787 or

More information

Submittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499]

Submittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499] BC--1.0 03-01-1 Belt Drive Blower Coil Unit, Basic Unit Discharge ARGT. 1 4. See page 1 for filter rack details. 5. Base rail is optional on he base unit. See page 13. Base rails must be used with mixing

More information

McQuay. Enfinity Horizontal Water Source Heat Pump. WCRH, WCRW 007, 009, 012 Design 1. Replacement Parts List No Revision B 02/2018

McQuay. Enfinity Horizontal Water Source Heat Pump. WCRH, WCRW 007, 009, 012 Design 1. Replacement Parts List No Revision B 02/2018 Replacement Parts List No. 700011100 Revision B 02/2018 McQuay Enfinity Horizontal Water Source Heat Pump WCRH, WCRW 007, 009, 012 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Water Source Heat Pump. HPH, HPV Vintage A, B. Last Manufactured: Replacement Parts List No Revision B 05/2012

McQuay. Water Source Heat Pump. HPH, HPV Vintage A, B. Last Manufactured: Replacement Parts List No Revision B 05/2012 Replacement Parts List No. 055211500 Revision B 05/2012 McQuay Water Source Heat Pump HPH, HPV 009-059 Vintage A, B Last Manufactured: 1986 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW Design 2. Replacement Parts List No Revision F 04/2018

Daikin. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW Design 2. Replacement Parts List No Revision F 04/2018 Replacement Parts List No. 700050900 Revision F 04/2018 Daikin Enfinity Horizontal Water Source Heat Pump WCCH, WCCW 072-120 Design 2 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Reciprocating Condensing Unit. ALP Vintage C. Last Manufactured: Replacement Parts List No Revision W 10/2017

McQuay. Reciprocating Condensing Unit. ALP Vintage C. Last Manufactured: Replacement Parts List No Revision W 10/2017 Replacement Parts List No. 700015000 Revision W 10/2017 McQuay Reciprocating Condensing Unit ALP 013-230 Vintage C Last Manufactured: 2002 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. EnerSaver Packaged Terminal Air Conditioner/Heat Pump. PNES; PNHS Design C (3)

Daikin McQuay. EnerSaver Packaged Terminal Air Conditioner/Heat Pump. PNES; PNHS Design C (3) Replacement Parts List No. 700018700 Revision E 04/2015 Daikin McQuay EnerSaver Packaged Terminal Air Conditioner/Heat Pump PNES; PNHS 009-015 Design C (3) To find your Daikin Applied parts distributor,

More information

Daikin McQuay. Incremental. Suite II, 2 Motor PDES Design C (3) Last Manufactured: 2008

Daikin McQuay. Incremental. Suite II, 2 Motor PDES Design C (3) Last Manufactured: 2008 Replacement Parts List 700018500 Revision B 02/2012 Daikin McQuay Incremental Suite II, 2 Motor PDES 009-015 Design C (3) Last Manufactured: 2008 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 042, 048, 060, 070 Design 5

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 042, 048, 060, 070 Design 5 Replacement Parts List No. 700027900 Revision M 09/2018 Daikin McQuay Enfinity Horizontal Water Source Heat Pump WCCH, WCCW 042, 048, 060, 070 Design 5 To find your Daikin Applied parts distributor, call

More information

Daikin. SmartSource Compact Vertical Water Source Heat Pump. WGCV 048, 060, 070 Design 1. Replacement Parts List No Revision D 01/2018

Daikin. SmartSource Compact Vertical Water Source Heat Pump. WGCV 048, 060, 070 Design 1. Replacement Parts List No Revision D 01/2018 Replacement Parts List No. 700052400 Revision D 01/2018 Daikin SmartSource Compact Vertical Water Source Heat Pump WGCV 048, 060, 070 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. Air- Cooled Condenser. ACH, ACX, ACL Vintage A. Replacement Parts List No Revision C 10/2016

Daikin McQuay. Air- Cooled Condenser. ACH, ACX, ACL Vintage A. Replacement Parts List No Revision C 10/2016 Replacement Parts List No. 700023300 Revision C 0/206 Daikin McQuay Air- Cooled Condenser ACH, ACX, ACL 04-225 Vintage A To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com

More information

McQuay. Superpak Applied Rooftop Units. RRS, RSS Vintage B. Last Manufactured: Replacement Parts List No Revision I 09/2017

McQuay. Superpak Applied Rooftop Units. RRS, RSS Vintage B. Last Manufactured: Replacement Parts List No Revision I 09/2017 Replacement Parts List No. 110502600 Revision I 09/2017 McQuay Superpak Applied Rooftop Units RRS, RSS 018-071 Vintage B Last Manufactured: 1997 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Seasonmaker Fan Coil. TSF, TSB, TSC Vintage C. Last Manufactured: Replacement Parts List No Revision D 09/2016

McQuay. Seasonmaker Fan Coil. TSF, TSB, TSC Vintage C. Last Manufactured: Replacement Parts List No Revision D 09/2016 Replacement Parts List No. 055211000 Revision D 09/2016 McQuay Seasonmaker Fan Coil TSF, TSB, TSC 021-151 Vintage C Last Manufactured: 1989 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Incremental. MEK, MHK Vintage A. PKES, PKHS, PRKC, PRKH Design A (1) Replacement Parts List No Revision G 07/2017

McQuay. Incremental. MEK, MHK Vintage A. PKES, PKHS, PRKC, PRKH Design A (1) Replacement Parts List No Revision G 07/2017 Replacement Parts List No. 057110000 Revision G 07/2017 McQuay Incremental MEK, MHK 019-022 Vintage A PKES, PKHS, PRKC, PRKH 019-022 Design A (1) To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay Climate Control Singer. Rooftop Unit. ER, R 250 Vintage C, D. Last Manufactured: Replacement Parts List No Revision C 04/2002

McQuay Climate Control Singer. Rooftop Unit. ER, R 250 Vintage C, D. Last Manufactured: Replacement Parts List No Revision C 04/2002 Replacement Parts List No. 779200800 Revision C 04/2002 McQuay Climate Control Singer Rooftop Unit ER, R 250 Vintage C, D Last Manufactured: 1996 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1 Replacement Parts List No. 700024700 Revision M 11/2017 Daikin Daikin McQuay SmartSource Single Stage Horizontal Water Source Heat Pump WGSH 007, 009, 012 Design 1 To find your Daikin Applied parts distributor,

More information

Installation, Start-Up and Service Instructions

Installation, Start-Up and Service Instructions 39M Central Station Air-Handling Units Sizes 03-30 Installation, Start-Up and Service Instructions CONTENTS Page INTRODUCTION.................................. 1 SAFETY CONSIDERATIONS......................

More information

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1 Replacement Parts List No. 700024700 Revision O 10/2018 Daikin Daikin McQuay SmartSource Single Stage Horizontal Water Source Heat Pump WGSH 007, 009, 012 Design 1 To find your Daikin Applied parts distributor,

More information

SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL

SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL SO TOUGH, WE GUARANTEE IT. SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL SBH SBV www.superiorrex.com SO TOUGH, WE GUARANTEE IT! www.superiorrex.com SBH / SBV Series: CONSTRUCTION FEATURES

More information

Daikin Daikin McQuay. SmartSource Single Stage Vertical Water Source Heat Pump. WGSV 007, 009, 012 Design 1

Daikin Daikin McQuay. SmartSource Single Stage Vertical Water Source Heat Pump. WGSV 007, 009, 012 Design 1 Replacement Parts List No. 700029600 Revision L 11/2017 Daikin Daikin McQuay SmartSource Single Stage Vertical Water Source Heat Pump WGSV 007, 009, 012 Design 1 To find your Daikin Applied parts distributor,

More information

SUBMITTAL DATA. for. MWSU-Popplewell Hall 1st Floor

SUBMITTAL DATA. for. MWSU-Popplewell Hall 1st Floor SUBMITTAL DATA for Prepared by Kevyn Gordon 4/27/2017 Job Name: 1 of 35 www.daikinapplied.com Table of Contents Technical Data Sheet for AHU-1st Floor... 3 Fan Curve for AHU-1st Floor... 7 Drawing for

More information

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW Design 1. Replacement Parts List No Revision I 12/2015

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW Design 1. Replacement Parts List No Revision I 12/2015 Replacement Parts List No. 700014800 Revision I 12/2015 Daikin McQuay Vertical Stack Water Source Heat Pump WVHC, WVHF, WVHW 009-036 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. Enfinity Vertical Water Source Heat Pump. WVFC, WVFW Design 1. Replacement Parts List No Revision S 01/2018

Daikin McQuay. Enfinity Vertical Water Source Heat Pump. WVFC, WVFW Design 1. Replacement Parts List No Revision S 01/2018 Replacement Parts List No. 700012100 Revision S 01/2018 Daikin McQuay Enfinity Vertical Water Source Heat Pump WVFC, WVFW 009-070 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW 036 Design 2. Replacement Parts List No Revision A 12/2015

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW 036 Design 2. Replacement Parts List No Revision A 12/2015 Replacement Parts List No. 700050700 Revision A 12/2015 Daikin McQuay Vertical Stack Water Source Heat Pump WVHC, WVHF, WVHW 036 Design 2 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay Climate Control Singer. Rooftop Unit. ER, R 160 Vintage A, B, C, D. Last Manufactured: 1996

McQuay Climate Control Singer. Rooftop Unit. ER, R 160 Vintage A, B, C, D. Last Manufactured: 1996 Replacement Parts List No. 779200600 Revision B 07/2007 McQuay Climate Control Singer Rooftop Unit ER, R 160 Vintage A, B, C, D Last Manufactured: 1996 To find your Daikin Applied parts distributor, call

More information

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 015, 019 Design 1

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 015, 019 Design 1 Replacement Parts List No. 700024800 Revision N 10/2018 Daikin Daikin McQuay SmartSource Single Stage Horizontal Water Source Heat Pump WGSH 015, 019 Design 1 To find your Daikin Applied parts distributor,

More information

Daikin. Rebel Commercial Air Handler. DAH A03 - A11 Vintage A. Replacement Parts List No Revision D 06/2018

Daikin. Rebel Commercial Air Handler. DAH A03 - A11 Vintage A. Replacement Parts List No Revision D 06/2018 Replacement Parts List No. 700052500 Revision D 06/208 Daikin Rebel Commercial Air Handler DAH A03 - A Vintage A To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com

More information

Daikin Daikin McQuay. Rebel Commercial Packaged Rooftop Cooling and Heating. DPS Vintage A

Daikin Daikin McQuay. Rebel Commercial Packaged Rooftop Cooling and Heating. DPS Vintage A Replacement Parts List No. 700023600 Revision AK 07/208 Daikin Daikin McQuay Rebel Commercial Packaged Rooftop Cooling and Heating DPS 007-02 Vintage A To find your Daikin Applied parts distributor, call

More information

ComfortPac 42 x 16. PTAC, PTHP Sizes Vintages B and B+ (2) Replacement Parts List No Rev. P 1/2012

ComfortPac 42 x 16. PTAC, PTHP Sizes Vintages B and B+ (2) Replacement Parts List No Rev. P 1/2012 Replacement Parts List No. 110511900 Rev. P 1/2012 ComfortPac 42 x 16 PTAC, PTHP Sizes 07-15 Vintages B and B+ (2) To find your McQuay parts distributor, call 1-800-377-2787 or visit www.mcquay.com Table

More information

Daikin McQuay. Thinline Horizontal Fan Coils and Cabinet Unit Heaters. FCHC, FCHH, FCHR FHHC, FHHH, FHHR 02, 03, 04, 06, 08, 10, 12 Design 1

Daikin McQuay. Thinline Horizontal Fan Coils and Cabinet Unit Heaters. FCHC, FCHH, FCHR FHHC, FHHH, FHHR 02, 03, 04, 06, 08, 10, 12 Design 1 Replacement Parts List No. 700026400 Revision N 01/2018 Daikin McQuay Thinline Horizontal Fan Coils and Cabinet Unit Heaters FCHC, FCHH, FCHR FHHC, FHHH, FHHR 02, 03, 04, 06, 08, 10, 12 Design 1 To find

More information

Issue 4 (Record Only) Job #: Innovent Submittal Date: October 30, 2012 Project: Location: Columbus, OH Innovent Job #: Submittal Issue: 4 (Record Only) Engineer: Contractor: Tag Innovent Model # AHU-BG-01

More information

McQuay. Global Air-Cooled Scroll Chiller. AGZ Vintage A Two-circuit. Last Manufactured: 2005

McQuay. Global Air-Cooled Scroll Chiller. AGZ Vintage A Two-circuit. Last Manufactured: 2005 Replacement Parts List No. 057117900 Revision R 10/2016 McQuay Global Air-Cooled Scroll Chiller AGZ 030-065 Vintage A Two-circuit Last Manufactured: 2005 To find your Daikin Applied parts distributor,

More information

McQuay. Steam/Hot Water Unit Heater. UDH Vintage C. Last Manufactured: Replacement Parts List No Revision New 07/2010

McQuay. Steam/Hot Water Unit Heater. UDH Vintage C. Last Manufactured: Replacement Parts List No Revision New 07/2010 Replacement Parts List No. 700018100 Revision New 07/2010 McQuay Steam/Hot Water Unit Heater UDH 040-960 Vintage C Last Manufactured: 1992 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Westinghouse. Rooftop Heating and Cooling. IK 180 Vintage 0, 1, 2, 3, 4. Last Manufactured: 1975

Westinghouse. Rooftop Heating and Cooling. IK 180 Vintage 0, 1, 2, 3, 4. Last Manufactured: 1975 Replacement Parts List No. 055227700 Revision A 03/2003 Westinghouse Rooftop Heating and Cooling IK 180 Vintage 0, 1, 2, 3, 4 Last Manufactured: 1975 To find your Daikin Applied parts distributor, call

More information

VERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT

VERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT VERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT SIZES FROM 600 TO 4,000 All Technical Specifications are Subject to Change without Notice.

More information

Westinghouse. Rooftop Heating and Cooling. IK 300 Vintage 0, 1, 2, 3, 4, 5. Last Manufactured: 1975

Westinghouse. Rooftop Heating and Cooling. IK 300 Vintage 0, 1, 2, 3, 4, 5. Last Manufactured: 1975 Replacement Parts List No. 055227900 Revision A 03/2003 Westinghouse Rooftop Heating and Cooling IK 300 Vintage 0,, 2, 3, 4, 5 Last Manufactured: 975 To find your Daikin Applied parts distributor, call

More information

McQuay. Console Water Source Heat Pump. CWC, CWG, CWH, CWJ, CWK Vintage B. Last Manufactured: 1994

McQuay. Console Water Source Heat Pump. CWC, CWG, CWH, CWJ, CWK Vintage B. Last Manufactured: 1994 Replacement Parts List No. 057101700 Revision B 02/2017 McQuay Console Water Source Heat Pump CWC, CWG, CWH, CWJ, CWK 015-019 Vintage B Last Manufactured: 1994 To find your Daikin Applied parts distributor,

More information

Daikin Daikin McQuay. Rebel Commercial Packaged Rooftop Cooling and Heating. DPS Vintage A

Daikin Daikin McQuay. Rebel Commercial Packaged Rooftop Cooling and Heating. DPS Vintage A Replacement Parts List No. 700024200 Revision AE 0/209 Daikin Daikin McQuay Rebel Commercial Packaged Rooftop Cooling and Heating DPS 005-006 Vintage A To find your Daikin Applied parts distributor, call

More information

RERV & RERVX RERVLP. Rotary Energy Recovery Ventilators. Low Profile Indoor Rotary Energy Recovery Ventilators

RERV & RERVX RERVLP. Rotary Energy Recovery Ventilators. Low Profile Indoor Rotary Energy Recovery Ventilators Version: Dec. 01, 2004 RERV & RERVX Rotary Energy Recovery Ventilators Indoor and Outdoor Installations 250 20,000 CFM Capacities RERVLP Low Profile Indoor Rotary Energy Recovery Ventilators Ideal for

More information

McQuay. Air Cooled Screw Chiller. ALS Vintage B. Last Manufactured: Replacement Parts List No Revision C 06/2017

McQuay. Air Cooled Screw Chiller. ALS Vintage B. Last Manufactured: Replacement Parts List No Revision C 06/2017 Replacement Parts List No. 700027300 Revision C 06/2017 cquay Air Cooled Screw Chiller ALS 300-425 Vintage B Last anufactured: 2001 To find your Daikin Applied parts distributor, call 1-800-377-2787 or

More information

Daikin Daikin McQuay. Rebel Commercial Packaged Rooftop Cooling and Heating. DPS Vintage A

Daikin Daikin McQuay. Rebel Commercial Packaged Rooftop Cooling and Heating. DPS Vintage A Replacement Parts List No. 700024300 Revision AA 08/208 Daikin Daikin McQuay Rebel Commercial Packaged Rooftop Cooling and Heating DPS 003-004 Vintage A To find your Daikin Applied parts distributor, call

More information

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL REPLACEMENT PARTS MANUAL WALL MOUNTED PACKAGED AIR CONDITIONER Models: W1AA-A WAA-A WAA-B WAA-C WAA-D WAA-F General Notes Revised and/or additional pages may be issued from time to time. A complete and

More information

MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING

MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING SIZES FROM 600 TO 9,000 All Technical Specifications are Subject to Change without Notice.

More information

HORIZONTAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT

HORIZONTAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT HORIZONTAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT MADE IN USA SIZES FROM 600 TO 9,000 All Technical Specifications are Subject to Change

More information

MAH. Modular Air Handling Unit

MAH. Modular Air Handling Unit MA Modular Air andling Unit 500 to 11,000 CFM @ up to 6.00 TSP 2 and 4 double wall construction, perforated or solid lined 18 gauge G0 galvanized steel cabinet 26 standard cabinet sizes available Internally

More information

FHP MANUFACTURING PARTS PRICE LIST

FHP MANUFACTURING PARTS PRICE LIST FHP MANUFACTURING PARTS PRICE LIST All models in this price sheet reflect our current vintage. For discontinued models please contact the factory. To ensure you receive the correct part please have the

More information

ROOF TOP SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING

ROOF TOP SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING ROOF TOP SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING MADE IN USA SIZES FROM 600 TO 9,000 All Technical Specifications are Subject to Change without

More information

FHP MANUFACTURING PARTS PRICE LIST

FHP MANUFACTURING PARTS PRICE LIST FHP MANUFACTURING PARTS PRICE LIST All models in this price sheet reflect our current vintage. For discontinued models please contact the factory. To ensure you receive the correct part please have the

More information