McQuay. Large Capacity Fan Coil Belt Drive. SCB, SHB Vintage B. FCZA, FCZC, FCZH, FHZA, FHZC, FHZH S08 - S30 Design A (1)

Size: px
Start display at page:

Download "McQuay. Large Capacity Fan Coil Belt Drive. SCB, SHB Vintage B. FCZA, FCZC, FCZH, FHZA, FHZC, FHZH S08 - S30 Design A (1)"

Transcription

1 Replacement Parts List No Revision U 0/208 McQuay Large Capacity Fan Coil Belt Drive SCB, SHB Vintage B FCZA, FCZC, FCZH, FHZA, FHZC, FHZH S08 - S30 Design A () To find your Daikin Applied parts distributor, call or visit

2 Contents About the Model Number Changes...2 Parts List Revision History...3, 4 Nomenclature Serial Number...5 Unit Model Number...5 Model Number SCB, SHB...6 Model Number FCZA, FCZC, FCZH, FHZA, FHZC, FHZH...7 Field Installed Accessories SHB/SCB Secondary Drain Pan for SHB...8 Return Air Plenum Filters for SHB...8 Vibration Isolators...8 Heating Coil Kit (includes duct collar)...8 Field Installed Accessories FCZA, FCZC, FCZH, FHZA, FHZC, FHZH Secondary Drain Pans...9 Heating Coil Kit (includes duct collar, angles, gasketing)...9 Vibration Isolators...9 Filters- FCZA, FCZC, FCZH...9 Filters- FCZA, FCZC, FCZH...9 Hanging Rails- FCZA, FCZC, FCZH Only...0 Double Deflection Grille- FCZA, FCZC, FCZH Only...0 Stamped Grille- FCZA, FCZC, FCZH Only...0 ¾" Duct Collar- FCZA, FCZC, FCZH Only...0 Perimeter Gasketing...0 Transformer...0 Wall Thermostats / Belt Duty Motors- Field Installed... Drive Sets- Field Installed...2 Cooling Coils Manual Air Valve B/S08, 2B/S B/S6, 20B/S20, 30B/S Reheat Coils 08B/S08, 2B/S B/S6, 20B/S20, 30B/S Unit Assembly SCB 08B, 2B/ FCZA, FCZC, FCZH S08, S SCB 6B, 20B, 30B/ FCZA, FCZC, FCZH S6, S20, S SHB 08B, 2B/ FHZA, FHZC, FHZH S08, S2...23, 24 SHB 6B, 20B, 30B/ FHZA, FHZC, FHZH S6, S20, S , 26 Factory Supplied Motors SCB, SHB "B"...27 FCZC, FHZC, FCZH, FHZH...28 Drive Components SCB, SHB 08B, 2B...29 SCB, SHB 6B, 20B, 30B...30 FCZC, FHZC, FCZH, FHZH...3 Critical Parts List SCB, SHB CPL FCZC, FHZC, FCZH, FHZH S08-S30...CPL2 About the Model Number Changes In 999 the model numbering nomenclature for the Large Capacity Belt Driven Fan Coil changed: The SCB "B" Vintage unit is now the FCZA or FCZC or FCZH Design "A" unit. The SHB "B" Vintage unit is now the FHZA or FHZC or FHZH Design "A" unit. The unit's components did not change when the nomenclature did (a few engineering changes have taken place since this RPL was last issued, and the part number changes are noted). The complete model number nomenclature currently used has been added to this revision. Unless otherwise noted, all components listed in this revision apply to both the current and the original model numbered units. Fan Coil; SCB,SHB 08-30B/FCZA,FCZC,FCZH,FHZA,FHZC,FHZH Des. Rev. U 0/8 RPL /Page 2

3 Rev. Date Description Parts List Revision History 9/88 New A 3/99 Reformatted, made changes to fan deck, new color cabinetry, added stock accessories, and field installed items. B 3/00 Page 7 - Change description on 08,2,6 & 20B Evap. DX-4 & 6 Row coils, C03=R,N (LH) Page 9-6B Reheat Coil,2-Row after 5/97 had p/n change to Page 3 -Added ref #85 to diagram. Page 4 - Added ref #85 to list - Motor Mount Support # Page 2 - D*, 075 V, C ----Voltage is 200/60/. Page 2 - D,.075 V, C After 8/96 p/n is C 7/00 Page 8- Made change to '2B COILS - Reheat Coil-(After 5/97)' p/n to Page 6-Made change to Fan Sheave (after 7/90)C09=B05, p/n to D 5/0 Page 3 & 4 - Bubble # 76 - removed. Page 4 - Bubble # 66 description changed to read Fan Housing. - Added (**)to size 30 indicating that size 30 includes the housing, mount and cutoff plate.- Deleted pn (size 30). E 2/0 Page 9-20B Coils, -Row Reheat Coil, Ref. # After 5/97; change p/n to Row Reheat Coil, Ref. # After 5/97; change p/n to B Coils, -Row Reheat Coil, Ref. # After 5/97; change p/n to Row Reheat Coil, Ref. # After 5/97; change p/n to Page - Ref #69; added 'goes with key #023223' to Fan Shaft until 7/90, and added 'goes with key # ' to Fan Shaft after 7/90. F 3/02 Page 20 - Ref. # 69 Fan Shaft pn for SCB 6B & 20B were reversed. Headings were incorrectly listed as SCB instead of SHB. G 0/02 Added new model numbers FCZA/FCZC/FCZH/FHZA/FHZC/FHZH. Page 5- Added "post 2/99" serial number nomenclature, and new model number nomenclature. Page 7- New page. Pages 3 thru 5- Added new nomenclature to headings. Page 6- Added new nomenclature to headings. Added ref. # 35, 43. Page 7- Updated p/n for ref# 66, 20, 34, 44. Added item #43, Baffle. Ref# 7 & 72 moved to next page. Page 8- Removed Drive Component part umbers and moved to separate page and added note. Added item 72 (after 4/0). Page 9- Added ref# 35, 46 and ref # 76 to the 30B/S30 Fan Deck diagram. Page 20-Ref# 65 added Blower Side Angle for size 30. Ref# 66 change p/n for size 30 to Ref# 72 p/n for sizes 6 and 20 were reversed. Changed size 20 qty. to two(2). Ref# 75 p/n for sizes 6 and 20 were reversed. Size 30 p/n changed to Ref# 76 added new. Ref# 20 p/n for size 6 LH unit changed to p/n for size 6, 20 & 30 changed to , & respectively. Ref# 25 removed notes regarding codes. Added note explaining drain pan applications. Ref# 29 removed note regarding motor frame application. Removed second line and added note explaining consolidation of p/n. Ref# 34 added RH and LH drain pans. Ref# 35 Added new. Ref# 4 thru 7 moved to next page. Pg. 2- Ref# 4 p/n for size 6 changed to Change P/N for size 30 to Ref# 42 p/n for size 30 changed to Ref# 43 changed description to Baffle. Ref# 44 p/n for all three sizes changed. Ref# 45 p/n for size 30 changed to Ref# 46 added new. Ref# 79 p/n for size 6 changed to Ref# 292,293 drive components removed and moved to separate table. Ref# 294,300 moved from subsequent page (subsequent page removed). Page 22- added ref# 35 to diagram. Page 23- N/S fan sheave key added for units built after 4/90. Ref# 66 p/n for size 2 changed to Ref# 20 size 08 LH change p/n to , p/n for size 2 LH changed to Ref #N/S Return Air Plenum Assy p/n for size 08 changed to , size 2 changed to Page 24- added Ref# 35 to diagram. Continued on next page Fan Coil; SCB,SHB 08-30B/FCZA,FCZC,FCZH,FHZA,FHZC,FHZH Des. Rev. U 0/8 RPL /Page 3

4 Rev. Date Description Parts List Revision History G 0/02 Page 25- Ref# 65 added size 30 Angle. Ref# 66 p/n for size 6 changed to (Continued) Ref# 72 p/n for size 6 changed to Ref# 76 p/n for size 6 changed to , size 20 changed to , size 30 changed to Ref# 20 p/n for size 6 LH changed to 06550, size 6 RH changed to , size 20 RH changed to , size 30 RH changed to Ref# 3 p/n for sizes 20 & 30 corrected base # to Ref# 35 added new. Ref# N/S Return Air Plenum Assy size 20 changed to Added notes 7 & 8. Pages 27 thru 30 added new. H 0/02 Page - Added Wall Thermostat chart. J 9/05 Pages 8, 2, 23, 25 - Added Junction box and Junction box cover. K 7/06 Page 20 - Bub#65 for SCB 30B part number changed from to Bub # 75 - SCB 30B pn changed from to L 8/06 Page 7 - Bub #67 (after 7/90) pn's were changed to M 6/07 Page 2 -S6, S20 Drive Sets Motor Sheave 43/45T changed p/n to N /08 Page7, 20 - Note change from SMG Parts Tech to McQuay Parts. O 04/0 Page 9- Change 2-row heating coil kit(coil only) S2 p/n to P 2/2 Page 9- Change RH drain pan S20 p/n to Add RH drain pan S30 p/n and LH drain pan S30 p/n Page 3- Change coils 08B/S08 p/n to & to B/S2 Coils- p/n to and to B/S6 Coils- p/n to and to B/S20 Coils- p/n to and to B/S30 Coils- p/n to and to Page 4- Change 08B/S08, p/n to and p/n to Change 2B/S2, p/n to and p/n to Page 5- Change 6B/S6, p/n to and p/n to Change 20B/S20, p/n to and p/n to Change 30B/S30, p/n to and p/n to Page CPL- Add Critical Parts List. Q 3/2 Page 2- Ref # 79 Change duct angle, antique white p/n (2) to (2). R /5 Rebrand Daikin format. Numerous changes, Sheet metal deleted and footnote added. Page 7- Ref #s 67 & 69 change date from 7/90 to 7/09. Page 27- Behind title add Low Airflow to FCXC, FHZC & add High Airflow behind title FCZH, FHZH. CPL-CPL2 Rebrand to Daikin format. CPL= SCB, SHB; CPL2= FCZX, FHZX. S 05/6 Pages 3-4- Update coils with old part numbers that were "until 2/08". Add footnote that 4 Row water Coil- No longer offered. Page 5-6 Reheat coil charts redone. Page added. CPL-CPL2 Update revision. T /7 Page 9- Delete Secondary Drain Pan p/n Pages 8 & 2- Change secondary drain pan Ref # 25 p/n to Delete drain pan- LH & RH part numbers are in Field Installed Accessories. U 0/8 Pages 20-2 Bub# 65 Change Fan Housing to Angle Support & Qty from to 2 for p/n Change Bub # 65 to Bub # 66 for S6, S20. Change Ref# 66 Fan Housing Assy Qty from to 2. Add Bolt L p/n Change Ref# 67 Bearing Angle Qty from 2 to 4. Change Ref #72 Qty from to 2. CPL-CPL2 Update revision. Daikin Applied, 3600 Industrial Park Blvd., P.O. Box 55, Minneapolis, MN (763) Fan Coil; SCB,SHB 08-30B/FCZA,FCZC,FCZH,FHZA,FHZC,FHZH Des. Rev. U 0/8 RPL /Page 4

5 Nomenclature Serial Number (until 2/999) 7 6A Serial Number (2/999 to present) AUB U Factory 7= Auburn, NY 5= Staunton, VA Serial Number Engineering Revision Year and Month of Manufacture: Year Month Q= 985 A= Jan. R= 986 B= Feb. S= 987 C= Mar. T= 988 D= Apr. U= 989 E= May V= 990 F= Jun W= 99 G= Jul X= 992 H= Aug Y= 993 J= Sep. Z= 994 K= Oct. 5= 995 L= Nov. 6= 996 M= Dec. 7= 997 8= 998 9= 999 U= Unit Plant Identification AUB = Auburn Serial Number (build sequence) Week of Manufacture Year of Manufacture 99= = = 200 etc. Unit Model Number- Original SCB 08 B Stock Unit Model Number- Original SCB 08 B R Vintage Application Series Vintage Application Series Unit Hand Nominal cfm in 00's ex. 08= 800 Unit Type: SCB- Ceiling Belt-Drive Large Capacity Fan Coil SHB- Hideaway Belt-Drive Large Capacity Fan Coil Nominal cfm in 00's ex. 08= 800 Unit Type: SCB- Ceiling Belt-Drive Large Capacity Fan Coil SHB- Hideaway Belt-Drive Large Capacity Fan Coil Unit Model Number- Current FCZA S2 Q Design Series = Design A Voltage Q= 5/208/230/60/ I= /230/460/60/3 Nominal cfm in 00's ex. S2= 200 Unit Type: FCZA= Horizontal Large Capacity Fan Coil, w/cabinet & Field Installed Motor FCZC= Horizontal Large Capacity Fan Coil, w/cabinet & Factory Installed Low HP Motor FCZH= Horizontal Large Capacity Fan Coil, w/cabinet & Factory Installed High HP Motor FHZA= Horizontal Large Capacity Fan Coil, No Cabinet & Field Installed Motor FHZC= Horizontal Large Capacity Fan Coil, No Cabinet & Factory Installed Low HP Motor FHZH= Horizontal Large Capacity Fan Coil, No Cabinet & Factory Installed High HP Motor Fan Coil; SCB,SHB 08-30B/FCZA,FCZC,FCZH,FHZA,FHZC,FHZH Des. Rev. U 0/8 RPL /Page 5

6 Nomenclature Model Number SCB, SHB SHB 08B R A A 3 D A02 C K 2 A Code Code 0 & 02= Unit Size and Vintage 08B= Nominal 800 Cfm 2B= Nominal 200 Cfm 6B= Nominal 600 Cfm 20B= Nominal 2000 Cfm 30B= Nominal 3000 Cfm Code 03= Unit Hand R= Right Hand Cooling Coil & Right Hand Motor L= Left Hand Cooling Coil & Right Hand Motor M= Left Hand Cooling Coil & Left Hand Motor N= Right Hand Cooling Coil & Left Hand Motor Code 05= Cooling Coil A= Standard Water Coil with Manual Air Vent (3 Row) B= Hi-Capacity Water Coil with Manual Air Vent (4 Row- no longer offered) C= Water Coil (6 Row) J= Standard DX Coil (4 Row) K= Hi-Capacity DX Coil (6 Row) Code 06= Optional Factory Installed Separate Reheat Coils Y= None A= Separate - Row Reheat Coil w/ Manual Air Vent B= Separate 2- Row Reheat Coil w/ Manual Air Vent Code 07= Secondary Drain Pan (SCB Only) = Secondary Drain Pan, Standard (carries field valve piping to primary drain pan) 3= Full length Drain Pan (extends from primary pan to the entering air side) Code 08= Discharge Air Grilles or Return Air Plenums A= Stamped Discharge Grille, Discharge Air Plenums (SCB) D= Double Deflection Grille, Discharge Air Plenums (SCB) E= Single Deflection Grille, Discharge Air Plenums (SCB) B= Duct Collar, Discharge Air Plenums (SCB) Y= Hanging Rails Only, Return Air Plenums (SHB) P= Factory Installed Plenum, Return Air Plenums (SHB) Code 09= Drive Selection A0= 48 Frame Motor RPM: Unit Sizes 08, 2 A02= 48 Frame Motor RPM: Unit Sizes 08, 2 A03= 48 Frame Motor RPM: Unit Sizes 08, 2 A04= 48 Frame Motor RPM: Unit Sizes 08, 2 A05= 48 Frame Motor RPM: Unit Size 6 A06= 48 Frame Motor RPM: Unit Size 6 B0= 56 Frame Motor RPM: Unit Sizes 08, 2 B02= 56 Frame Motor RPM: Unit Sizes 08, 2 B03= 56 Frame Motor RPM: Unit Sizes 6, 20 B04= 56 Frame Motor RPM: Unit Sizes 6, 20 B05= 56 Frame Motor RPM: Unit Sizes 6, 20 B06= 56 Frame Motor RPM: Unit Sizes 6, 20 B07= 56 Frame Motor RPM: Unit Size 30 B08= 56 Frame Motor RPM: Unit Size 30 B09= 56 Frame Motor RPM: Unit Size 30 B0= 56 Frame Motor RPM: Unit Size 30 C0= 43/45 Frame Motor 86-0 RPM: Unit Sizes 6, 20 C02= 43/45 Frame Motor RPM: Unit Sizes 6, 20 C03= 43/45 Frame Motor RPM: Unit Sizes 6, 20 C04= 43/45 Frame Motor RPM: Unit Size 30 C05= 43/45 Frame Motor 86-0 RPM: Unit Size 30 C06= 43/45 Frame Motor RPM: Unit Size 30 Code 0= Motor Horsepower A=.25 HP B=.33 HP C=.50 HP D=.75 HP E=.0 HP F=.5 HP G= 2.0 HP Code = Voltage K= 5/60/ L= 200/60/3 Q= 5/230/60/ V= 230/460/60/3 P= 277/60/ Code 2= Base/Bearing 2= Rigid Base/Ball Bearing 3= Resilient Base/Sleeve Bearing 4= Resilient Base/ Ball Bearing Code 4= Motor Mounted A= Factory Mounted B= by others Fan Coil; SCB,SHB 08-30B/FCZA,FCZC,FCZH,FHZA,FHZC,FHZH Des. Rev. U 0/8 RPL /Page 6

7 Nomenclature Model Number FCZA, FCZC, FCZH, FHZA, FHZC, FHZH FCZH S2 Q D 7 J 00 AY 8 A I Code Code 0= Unit Design Series (Vintage) = Design A Code 02= Unit Size (Capacity S08= 800 cfm S2= 200 cfm S6= 600 cfm S20= 2000 cfm S30= 3000 cfm Code 03= Voltage I= 230/460/60/3 Q= 5/208/230/60/ Z= None (field installed motor) Code 04= Coil Type D= 3- Row, CW/HW, 2- Pipe J= 6- Row, CW/HW K= 6- Row, CW/HW, wth full secondary drain pan Code 05= Heating Options 00= None 70= - Row Heating Coil 7= 2- Row Heating Coil Code 07= Controls 00= None Code 08= Discharge AY= Front (FCZA, FCZC, FCZH) AG= Stamped Grille (FCZC, FCZH) AX= Front w/duct (FHZA) Code 09= Return Air/Outdoor Air 8= Rear w/ Filter (cabinet units only) 7= Rear Ducted w/ Filter (hideaway units only) Code 0= Power Connection A= Junction Box Code = Color I= Antique Ivory (cabinet units only) Z= None (hideaway units only) Code 2= SKU Type Code 3= Product Style Code 06= Unit Hand J= Right Hand Coil/Right Hand Motor K= Right Hand Coil/Left Hand Motor L= Left Hand Coil/Left Hand Motor M= Left Hand Coil/Right Hand Motor Fan Coil; SCB,SHB 08-30B/FCZA,FCZC,FCZH,FHZA,FHZC,FHZH Des. Rev. U 0/8 RPL /Page 7

8 Field Installed Accessories SHB, SCB Secondary Drain Pan for SHB Description Unit Sizes Part Number Secondary Drain Pan All Return Air Plenum Filters for SHB Description Unit Sizes Part Number 2" Throwaway Filter 08B B B B B (2) 2" Cleanable Filter 08B B B B B (2) Vibration Isolators Description Unit Sizes Part Number Rubber-in-Shear Isolator All (4) Heating Coil Kit (includes duct collar) Description Unit Sizes Part Number - Row Heating Coil Kit 08B B B B B Row Heating Coil Kit 08B B B B B Fan Coil; SCB,SHB 08-30B/FCZA,FCZC,FCZH,FHZA,FHZC,FHZH Des. Rev. U 0/8 RPL /Page 8

9 Field Installed Accessories FCZA, FCZC, FCZH, FHZA, FHZC, FHZH Secondary Drain Pans Part Number Description Unit Sizes Left Hand Right Hand Drain Pan Assy S08, S Drain Pan Assy S Drain Pan Assy S Drain Pan Assy S Heating Coil Kit (includes duct collar, angles, gasketing) Description Unit Sizes Kit Coil Only Gasket - Row Heating Coil Kit S (2) S (2) S (2) S (2) S (2) 2- Row Heating Coil Kit S (2) S (2) S (2) S (2) S (2) Vibration Isolators Description Unit Sizes Part Number Kit (contains 4 R-I-S Isolators) All Rubber-in-Shear Isolator only All * *Quantity required: FCZ (4); FHZ (6). Filters- FCZA, FCZC, FCZH Description Unit Sizes 2 Pack Individual Filter- FCZA/FCZC/FCZH S06 - S S S Filters- FHZA, FHZC, FHZH Description Unit Sizes 2 Pack Individual Filter- FHZA/FHZC/FHZH S S S S S S Fan Coil; SCB,SHB 08-30B/FCZA,FCZC,FCZH,FHZA,FHZC,FHZH Des. Rev. U 0/8 RPL /Page 9

10 Field Installed Accessories FCZA, FCZC, FCZH, FHZA, FHZC, FHZH Continued Hanging Rails- FHZA, FHZC, FHZH Only Description Unit Sizes Part Number Hanging Rails Kit (rails + screws) All Double Deflection Grille- FCZA, FCZC, FCZH Only Description Unit Sizes Part Number Double Deflection Grille Kit (includes grille and screws) S S S S S Stamped Grille- FCZA, FCZC, FCZH Only Description Unit Sizes Part Number Stamped Grille Kit (includes painted grille and screws) S S S S S ¾" Duct Collar- FCZA, FCZC, FCZH Only Description Unit Sizes Part Number Duct Collar Kit (includes duct collar and screws) S S S S S Perimeter Gasketing Description Unit Sizes Part Number Gasket- 60 Foot Roll All Transformer Description Unit Sizes Part Number 20V- 24V, 75 VA All V- 20V, 300 VA All Fan Coil; SCB,SHB 08-30B/FCZA,FCZC,FCZH,FHZA,FHZC,FHZH Des. Rev. U 0/8 RPL /Page 0

11 Field Installed Accessories FCZA, FCZC, FCZH, FHZA, FHZC, FHZH Continued Wall Thermostats Application Unit Sizes Part Number 2 or 4 Pipe, 24 Volt, with On/Off or 3 Wire Floating, All Auto Changeover Thermister Probe for All or 4 Pipe, Fan/Valve Cycle, 3 Speed Switch, All Auto Changeover 2 or 4 Pipe, Fan/Valve Cycle, 3 Speed Switch, All Manual Changeover 2 or 4 Pipe, Fan/Valve Cycle, No Speed Switch, All Auto Changeover 2 Pipe, SPST, 2" X 4" All " X 4" Adapter Plate All Belt Duty Motors Horsepower Frame Size Voltage Part No. /3 48 5/208/230/60/ /230/60/ /4 48 5/230/60/ /230/60/ /2 56 5/208/230/60/ /60/ /60/ /4 56 5/208/230/60/ /60/ /60/ /230/460/60/ /208/230/60/ /60/ T 200/60/ T 230/460/60/ /2 56 5/208/230/60/ T 265/60/ T 200/60/ T 230/460/ T 200/60/ T 230/460/60/ Fan Coil; SCB,SHB 08-30B/FCZA,FCZC,FCZH,FHZA,FHZC,FHZH Des. Rev. U 0/8 RPL /Page

12 Field Installed Accessories FCZA, FCZC, FCZH, FHZA, FHZC, FHZH Continued S08, S2 Drive Sets- Field Installed Motor Frame RPM Range Kit PN Motor Sheave Fan Sheave Belt S6, S20 Drive Sets- Field Installed Motor Frame RPM Range Kit PN Motor Sheave Fan Sheave Belt /45T /45T /45T /45T S30 Drive Sets- Field Installed Motor Frame RPM Range Kit PN Motor Sheave Fan Sheave Belt /45T /45T /45T Fan Coil; SCB,SHB 08-30B/FCZA,FCZC,FCZH,FHZA,FHZC,FHZH Des. Rev. U 0/8 RPL /Page 2

13 Cooling Coils 08B/S08-2B/S2 Manual Air Valve Decription Unit Sizes Part Number Air Valve * All * Three (3) row coils only. 08B, S08 Coils Description C03= C05= Part Number Evaporator Std, DX- 4 Row L, M J Evaporator Hi-Cap, DX- 6 Row L, M K Evaporator Std, DX- 4 Row R, N J Evaporator Hi-Cap, DX- 6 Row R, N K Water, CW/HW- 3 Row, until 2/08 ALL A Water, CW/HW- 3 Row, 2/08 & later ALL A Water, CW/HW- 6 Row, until 2/08 ALL C Water, CW/HW- 6 Row, 2/08 & later ALL C No longer available. 2B, S2 Coils Description C03= C05= Part Number Evaporator Std, DX- 4 Row L, M J Evaporator Hi-Cap, DX- 6 Row L, M K Evaporator Std, DX- 4 Row R, N J Evaporator Hi-Cap, DX- 6 Row R, N K Water, CW/HW- 3 Row, until 2/08 ALL A Water, CW/HW- 3 Row, 2/08 & later ALL A Water, CW/HW- 6 Row, until 2/08 ALL C Water, CW/HW- 6 Row, 2/08 & later ALL C No longer available. Fan Coil; SCB,SHB 08-30B/FCZA,FCZC,FCZH,FHZA,FHZC,FHZH Des. Rev. U 0/8 RPL /Page 3

14 Cooling Coils 6B/S6-30B/S30 6B, S6 Coils Description C03= C05= Part Number Evaporator Std, DX- 4 Row L, M J Evaporator Hi-Cap, DX- 6 Row L, M K Evaporator Std, DX- 4 Row R, N J Evaporator Hi-Cap, DX- 6 Row R, N K Water, CW/HW- 3 Row, until 2/08 ALL A Water, CW/HW- 3 Row, 2/08 & later ALL A Water, Hi Cap, 4 Row ALL B Water, CW/HW- 6 Row, until 2/08 ALL C Water, CW/HW- 6 Row, 2/08 & later ALL C No longer available. 20B, S20 Coils Description C03= C05= Part Number Evaporator Std, DX- 4 Row L, M J Evaporator Hi-Cap, DX- 6 Row L, M K Evaporator Std, DX- 4 Row R, N J Evaporator Hi-Cap, DX- 6 Row R, N K Water, CW/HW- 3 Row, until 2/08 ALL A Water, CW/HW- 3 Row, 2/08 & later ALL A Water, Hi Cap, 4 Row ALL B Water, CW/HW- 6 Row, until 2/08 ALL C Water, CW/HW- 6 Row, 2/08 & later ALL C No longer available. 30B, S30 Coils Description C03= C05= Part Number Evaporator Std, DX- 4 Row L, M J Evaporator Hi-Cap, DX- 6 Row L, M K Evaporator Std, DX- 4 Row R, N J Evaporator Hi-Cap, DX- 6 Row R, N K Water, CW/HW- 3 Row, until 2/08 ALL A Water, CW/HW- 3 Row, 2/08 & later ALL A Water, Hi Cap, 4 Row ALL B Water, CW/HW- 6 Row, until 2/08 ALL C Water, CW/HW- 6 Row, 2/08 & later ALL C No longer available. Fan Coil; SCB,SHB 08-30B/FCZA,FCZC,FCZH,FHZA,FHZC,FHZH Des. Rev. U 0/8 RPL /Page 4

15 Reheat Coils 08B/S08-2B/S End Views (LH Coil Shown) SHB or FHZ() SCB or FCZ() 2 Front View B, S08 Coils Ref. Part No. Description Part Number Qty Reheat Coil, Row Water until 2/ Reheat Coil, Row Water 2/08 & later Reheat Coil, 2 Row Water until 2/ Reheat Coil, 2 Row Water 2/08 & later Screw F/SHD Plate F/SCD Blowoff F/SHD Top Duct Angle F/SHD Side Duct angle F/SHD Rear Duct Angle F/SHD & F/SCD N/S Bottom Duct angle F/SHD B, S2 Coils Ref. Part No. Description Part Number Qty Reheat Coil, Row Water until 2/ Reheat Coil, Row Water 2/08 & later Reheat Coil, 2 Row Water until 2/ Reheat Coil, 2 Row Water 2/08 & later Screw SHD/FHZ() Plate SCD/FCZ() Blowoff SHD/FHZ() Top Duct Angle SHD/FHZ() Side Duct angle SHD/FHZ() Rear Duct Angle N/S Bottom Duct angle SHD/FHZ() Fan Coil; SCB,SHB 08-30B/FCZA,FCZC,FCZH,FHZA,FHZC,FHZH Des. Rev. U 0/8 RPL /Page 5

16 6B or S6 Coils Reheat Coils 6B/S6-30B/S30 Ref. Part No. Description Part Number Qty Reheat Coil, Row Water until 2/ Reheat Coil, Row Water 2/08 & later Reheat Coil, 2 Row Water until 2/ Reheat Coil, 2 Row Water 2/08 & later Screw SHD/FHZ() Plate SCD/FCZ() Blowoff SHD/FHZ() Top Duct Angle SHD/FHZ() Side Duct angle SHD/FHZ() Rear Duct Angle N/S Bottom Duct angle SHD/FHZ() B or S20 Coils Ref. Part No. Description Part Number Qty Reheat Coil, Row Water until 2/ Reheat Coil, Row Water 2/08 & later Reheat Coil, 2 Row Water until 2/ Reheat Coil, 2 Row Water 2/08 & later Screw SHD/FHZ() Plate SCD/FCZ() Blowoff SHD/FHZ() Top Duct Angle SHD/FHZ() Side Duct angle SHD/FHZ() Rear Duct Angle N/S Bottom Duct angle SHD/FHZ() B or S30 Coils Ref. Part No. Description Part Number Qty Reheat Coil, Row Water until 2/ Reheat Coil, Row Water 2/08 & later Reheat Coil, 2 Row Water until 2/ Reheat Coil, 2 Row Water 2/08 & later Screw SHD/FHZ() Plate SCD/FCZ() Blowoff SHD/FHZ() Top Duct Angle SHD/FHZ() Side Duct angle SHD/FHZ() Rear Duct Angle N/S Bottom Duct angle SHD/FHZ() Fan Coil; SCB,SHB 08-30B/FCZA,FCZC,FCZH,FHZA,FHZC,FHZH Des. Rev. U 0/8 RPL /Page 6

17 Unit Assembly SCB 08B, 2B FCZA, FCZC, FCZH S08, S2 Diagrams 24 Cabinet/Chassis components Component Assembly (RH Unit Shown) Fan Deck Detail Cabinet Assembly (RH Unit Shown) Fan Coil; SCB,SHB 08-30B/FCZA,FCZC,FCZH,FHZA,FHZC,FHZH Des. Rev. U 0/8 RPL /Page 7

18 Unit Assembly SCB 08B, 2B FCZA, FCZC, FCZH S08, S2 Components Ref. Part SCB 08B SCB 2B Qty. No. Description FCZ() S08 FCZ() S2 N/S Fan Sheave Key until 7/ after 7/ Fan Bearing until 7/ after 7/ Blower Housing/Motor Mount Assembly Bearing Angle until 7/09- LH until 7/09- RH after 7/ Fan Wheel Fan Shaft until 7/09 (goes with key #023223) after 7/09 (goes with key # ) Cutoff Plate Drain Pan Assembly- LH Units Drain Pan Assembly- RH Units Fan Panel Assembly Bottom Plate 23 Top Plate 24 Hanger 2 25 Drain Pan- Secondary Blowoff Drain Pan (units w/reheat coil only) Motor Mount- 48/56 Frame Motor Drain Pan LH Unit RH Unit Corner Assembly 38 Angle Hanger Channel Bottom Cabinet Assembly 42 End Cabinet Panel Baffle 44 Side Cabinet Panel Top Cabinet Panel N/S Cabinet/Chassis Components N/S= Not Shown on Diagram. Contact Daikin with unit model and serial number for part numbers on Cabinet/Chassis components. 2 Mist Gray (until 2/98) & Antique Ivory (2/98 & later). 3 The secondary drain pan is standard on current models, and the full-length secondary pan is a field installed option. Originally the pans were coded production items (standard secondary pan when C07= ; full length drain pan when C07= 2). Fan Coil; SCB,SHB 08-30B/FCZA,FCZC,FCZH,FHZA,FHZC,FHZH Des. Rev. U 0/8 RPL /Page 8

19 Ref. Part SCB 08B SCB 2B Qty. No. Description FCZ() S08 FCZ() S2 7 Filter Frame 2 72 Filter Door 2 N/S Unit Assembly SCB 08B, 2B/ FCZA, FCZC, FCZH S08, S2 Components, Continued Filter- Throwaway Until 5/ After 5/ Stamped Grille Mist Gray (until 2/98) Antique Ivory (after 2/98) Duct Angle Collar Mist Gray (until 2/98) Antique Ivory (after 2/98) Single Deflection Grille Double Deflection Grille Steel Spacer Drain Pan Gasket Motor Sheave ** ** 293 Belt ** ** 294 Fan Sheave ** ** 300 Motor * * N/S Junction Box (4x4x.5) N/S Cover, Junction Box N/S= Not Shown on Diagram. Contact Daikin with unit model and serial number for part numbers on Cabinet/Chassis components. 2 Mist Gray (until 2/98) & Antique Ivory (2/98 & later). * See Motor Table following unit assembly sections. ** See Drive Components Table following Motor Table. Fan Coil; SCB,SHB 08-30B/FCZA,FCZC,FCZH,FHZA,FHZC,FHZH Des. Rev. U 0/8 RPL /Page 9

20 Unit Assembly SCB 6B, 20B, 30B/ FCZA, FCZC, FCZH S6, S20, S30 Diagrams Component Assembly (RH Unit Shown) Fan Deck Detail B, 20B/ S6, S20 Cabinet Assembly (RH Unit Shown) only used with a plenum B/ S Fan Coil; SCB,SHB 08-30B/FCZA,FCZC,FCZH,FHZA,FHZC,FHZH Des. Rev. U 0/8 RPL /Page 20

21 Unit Assembly SCB 6B, 20B, 30B FCZA, FCZC, FCZH S6, S20, S30 Components Ref. Part SCB 6B SCB 20B SCB 30B Qty. No. Description FCZ() S6 FCZ() S20 FCZ() S30 57 Key- Fan Sheave Fan Bearing until 7/ Fan Bearing after 7/ Angle Support, Motor Mount Angle Support, Blower Side Fan Housing Assy N/S Bolt L Angle Support, Bearing until 7/ Angle Support, Bearing after 7/ Fan Wheel Fan Shaft Cutoff Plate not used 2 75 Angle Support Housing Fan Housing/Mount Assy N/A N/A Motor Mount Angle Support Drain Pan Assembly LH Drain Pan Assembly RH N/S Secondary Drain Pan Fan Panel Assembly Bottom Plate 23 Top Plate 24 Hanger Drain Pan- Secondary Blowoff Drain Pan (units w/reheat coil only) Motor Mount Drain Pan LH Drain Pan RH Blower Plate Assembly N/S Gasket Corner Assembly 37 Corner Assembly 38 Angle 2 39 Hanger Channel 2 2 N/S Cabinet/Chassis Components N/A= Not Applicable. N/S= Not Shown on Diagram. Contact Daikin with unit model and serial number for part numbers on Cabinet/Chassis components. 2 Mist Gray (until 2/98) & Antique Ivory (2/98 & later). 3 The secondary drain pan is standard on current models, and the full-length secondary pan is a field installed option. Originally the pans were coded production items (standard secondary pan when C07= ; full length drain pan when C07= 3). 4 Until 4/99 there were two different motor mounts (one for 48/56 frame motors and one for 43/45 frame motors). The 48/56 frame mounts have been modified to function universally. 5 30B/S30 includes the fan housing, motor mount and cutoff plate. Fan Coil; SCB,SHB 08-30B/FCZA,FCZC,FCZH,FHZA,FHZC,FHZH Des. Rev. U 0/8 RPL /Page 2

22 Unit Assembly SCB 6B, 20B, 30B FCZA, FCZC, FCZH S6, S20, S30 Components, Continued Ref. Part SCB 6B SCB 20B SCB 30B Qty. No. Description FCZ() S6 FCZ() S20 FCZ() S30 4 Bottom Cabinet Assembly 42 End Cabinet Panel Baffle 44 Side Cabinet Panel Top Cabinet Panel Support 7 Filter Frame 2 72 Filter Door 2 N/S Filter- Throwaway Until 5/ After 5/ Stamped Grille (C08= A) 2 2 Duct Angle (C08= B) 2 4 Single Deflection Grille (C08= C) () Double Deflection Grille (C08= D) () Steel Spacer Drain Pan Gasket (C07= only) Motor Sheave ** ** ** 293 Belt ** ** ** 294 Fan Sheave ** ** ** 300 Motor * * * N/S Junction Box (4x4x.5) N/S Cover, Junction Box N/S Cabinet/Chassis Components N/S= Not Shown on Diagram. Contact Daikin with unit model and serial number for part numbers on Cabinet/Chassis components. 2 Mist Gray (until 2/98) & Antique Ivory (2/98 & later). * See Motor Table following unit assembly sections. ** See Drive Components Table following Motor Table. Fan Coil; SCB,SHB 08-30B/FCZA,FCZC,FCZH,FHZA,FHZC,FHZH Des. Rev. U 0/8 RPL /Page 22

23 Unit Assembly SHB 08B, 2B FHZA, FHZC, FHZH S08, S2 Diagrams Fan Deck Detail Fan Coil; SCB,SHB 08-30B/FCZA,FCZC,FCZH,FHZA,FHZC,FHZH Des. Rev. U 0/8 RPL /Page 23

24 Unit Assembly SHB 08B, 2B FHZA, FHZC, FHZH S08, S2 Components Ref. Part SHB 08B SHB 2B Qty. No. Description FHZ() S08 FHZ() S2 N/S Fan Sheave Key until 7/ after 7/ Fan Bearing until 7/ after 7/ Blower Housing/Motor Mount Assembly Bearing Angle until 7/90- LH until 7/90- RH after 7/ Fan Wheel Fan Shaft until 7/90 (uses Key ) after 7/90 (uses Key ) Cutoff Plate Drain Pan Assembly- LH Units Drain Pan Assembly- RH Units Fan Panel Assembly Bottom Plate Top Plate Hanger 5 units w/o plenum units w/plenum Blowoff Drain Pan (units w/reheat coil only) Motor Mount Duct Angle Left Side Right Side Gasket Hanger Channel Steel Spacer Motor Sheave ** ** 293 Belt ** ** 294 Fan Sheave ** ** 300 Motor * * N/S Junction Box (4x4x.5) N/S Cover, Junction Box N/S Return Air Plenum Assembly Top Panel Bottom Panel Rear Panel Access Panel Filter- Throwaway N/S= Not Shown on Diagram. NOTE: All part numbers listed in italics are NOT set up WDSII (not orderable). Please contact McQuay Parts ID Tech. 5 On early versions of the SHB the fan ass'y didn't have the integrated motor mount channel, but rather, the channel was mounted perpendicular between the hanger channels (ref. 39). The old motor channel p/n was , the old motor mount p/n was and the old hanger channel p/nwas * See Motor Table after the Unit Assembly pages. ** See Drive Components Table after Motor Table. Fan Coil; SCB,SHB 08-30B/FCZA,FCZC,FCZH,FHZA,FHZC,FHZH Des. Rev. U 0/8 RPL /Page 24

25 Unit Assembly SHB 6B, 20B, 30B FHZA, FHZC, FHZH S6, S20, S30 Diagrams Fan Deck Detail B, 20B/ S6, S B/ S30 Fan Coil; SCB,SHB 08-30B/FCZA,FCZC,FCZH,FHZA,FHZC,FHZH Des. Rev. U 0/8 RPL /Page 25

26 Unit Assembly SHB 6B, 20B, 30B / FHZA, FHZC, FHZH S6, S20, S30 Components Ref. Part SHB 6B SHB 20B SHB 30B Qty. No. Description FHZ() S6 FHZ() S20 FHZ() S30 57 Key- Fan Sheave Fan Bearing until 7/ after 7/ Fan Housing/Motor Mount Assembly Angle- Blower Side Fan Housing Assy Bearing Angle until 7/ after 7/ Fan Wheel Fan Shaft Cutoff Plate not used 75 Support Assy Fan Housing/Motor Mount/Cutoff Plate Assy not used not used Drain Pan Assembly- LH Units Drain Pan Assembly- RH Units Fan Panel Assembly Bottom Plate Top Plate Hanger 6 units w/o plenum (C08= Y) units with plenum (C08= P) Blowoff Drain Pan (units w/reheat coil only) Motor Mount 6, Angle Left Side Right Side Gasket Hanger Channel Steel Spacer Motor Sheave ** ** ** 293 Belt ** ** ** 294 Fan Sheave ** ** ** 300 Motor * * * N/S Return Air Plenum Assembly Top Panel Bottom Panel Rear Panel Access Panel Filter- Throwaway N/S Junction Box (4x4x.5) N/S Cover, Junction Box N/S= Not Shown on Diagram. 6 On early versions of the SHB the fan assembly did not have the integrated motor mount channel, but rather, the channel was mounted perpendicular between the hanger channels (ref. 39). The old motor channel part number was (6B) (20B) (30B), the old motor mount part number for 48/56 frame motors was and the old motor mount part number for 43/45 frame motors was and the old hanger channel part number was (6B & 20B) (30B). 7 Until 4/99 there were two different motor mounts (one for 48/56 frame motors and one for 43/45 frame motors). The 48/56 frame mounts have been modified to function universally. 8 Size 30 Fan Housing includes a cutoff plate. * See Motor Table after the Unit Assembly pages. ** See Drive Components Table after Motor Table. Fan Coil; SCB,SHB 08-30B/FCZA,FCZC,FCZH,FHZA,FHZC,FHZH Des. Rev. U 0/8 RPL /Page 26

27 Factory Supplied Motors SCB/SHB "B" Several of the motors shown below are no longer used in production. Over the years the options and the number of motors have been consolidated. For the purpose of product history all of the options ever offered and their associated motors are listed. In August, 996 a new family of motors replaced all previously used motors. All options noted with an asterisk (*) are offered with the new line of motors. C0 HP C Voltage C2 Base/Bearing Until After 8/96 8/96 A*.25 K 5/60/ 3 Res./Sleeve A*.25 L 200/60/3 2 Rigid Ball A.25 L 200/60/3 3 Res./Sleeve A.25 Q 5/230/60/ 2 Rigid/Ball A.25 Q 5/230/60/ 4 Res./Ball A.25 Q 5/230/60/ 3 Res./Sleeve A*.25 V 230/460/60/3 2 Rigid/Ball A.25 V 230/460/60/3 3 Res./Sleeve B*.33 K 5/60/ 3 Res./Sleeve B*.33 L 200/60/3 2 Rigid/Ball B.33 L 200/60/3 3 Res./Sleeve B.33 Q 5/230/60/ 2 Rigid/Ball B.33 Q 5/230/60/ 4 Res./Ball B.33 Q 5/230/60/ 3 Res./Sleeve B*.33 V 230/460/60/3 2 Rigid/Ball B.33 V 230/460/60/3 3 Res./Sleeve B*.33 P 277/60/ 4 Res./Ball C*.50 L 200/60/3 2 Rigid/Ball C.50 L 200/60/3 4 Res./Ball C.50 Q 5/230/60/ 2 Rigid/Ball C.50 Q 5/230/60/ 4 Res./Ball C*.50 Q 5/230/60/ 3 Res./Sleeve C*.50 V 230/460/60/3 2 Rigid/Ball C.50 V 230/460/60/3 4 Res./Ball C*.50 P 277/60/ 4 Res./Ball D*.75 L 200/60/ 2 Rigid/Ball D.75 L 200/60/3 4 Res./Ball D.75 Q 5/230/60/ 2 Rigid/Ball D.75 Q 5/230/60/ 4 Res./Ball D*.75 Q 5/230/60/ 3 Res./Sleeve D*.75 V 230/460/60/3 2 Rigid/Ball D.75 V 230/460/60/3 4 Res./Ball D*.75 P 277/60/ 4 Res./Ball E*.0 L 200/60/3 2 Rigid/Ball E*.0 Q 5/230/60/ 2 Rigid/Ball E*.0 V 230/460/60/3 2 Rigid/Ball E*.0 P 277/60/ 4 Res./Ball F*.5 L 200/60/3 2 Rigid/Ball F*.5 Q 5/230/60/ 4 Res./Ball F*.5 V 230/460/60/3 2 Rigid/Ball F*.5 P 277/60/ 2 Rigid/Ball G* 2.0 L 200/60/3 2 Rigid/Ball G 2.0 Q 5/230/60/ 4 Res./Ball G* 2.0 V 230/460/60/3 2 Rigid/Ball Fan Coil; SCB,SHB 08-30B/FCZA,FCZC,FCZH,FHZA,FHZC,FHZH Des. Rev. U 0/8 RPL /Page 27

28 Factory Supplied Motors FCZC, FHZC (Low Airflow) Unit Size Voltage HP/Frame Size Part Number S08 5/208/230/60/.333/ /460/60/3.333/ S2 5/208/230/60/.500/ /460/60/3.500/ S6 5/208/230/60/.500/ /460/60/3.500/ S20 5/208/230/60/.750/ /460/60/3.750/ S30 5/208/230/60/.000/ /460/60/3.000/45T Factory Supplied Motors FCZH, FHZH (High Airflow) Unit Size Voltage HP/Frame Size Part Number S08 5/208/230/60/.750/ /460/60/3.750/ S2 5/208/230/60/.750/ /460/60/3.750/ S6 5/208/230/60/.000/ /460/60/3.000/45T S20 5/208/230/60/.500/ /460/60/3.500/45T S30 5/208/230/60/.500/ /460/60/3.500/45T Fan Coil; SCB,SHB 08-30B/FCZA,FCZC,FCZH,FHZA,FHZC,FHZH Des. Rev. U 0/8 RPL /Page 28

29 Drive Components SCB, SHB 08B, 2B Ref. Part SCB SCB Qty. No. Description 08B 2B 292 Motor Sheave C09= A0 or A C09= A03 or A C09= B0 or B Belt- Until 7/90 (original fan design) C09= A C09= A02 or B C09= A03 or A C09= B Belt- After 7/90 (redesigned fan assembly) C09= A C09= A C09= A C09= A C09= B0 or B Fan Sheave- Until 7/90 (original fan design) C09= A C09= A02 or A03 or B C09= A04 or B Fan Sheave- After 7/90 (redesigned fan assy) C09= A C09= A02 or A03 or B C09= A04 or B Fan Coil; SCB,SHB 08-30B/FCZA,FCZC,FCZH,FHZA,FHZC,FHZH Des. Rev. U 0/8 RPL /Page 29

30 Drive Components SCB, SHB 6B, 20B, 30B Ref. Part SCB SCB SCB Qty. No. Description 6B 20B 292 Motor Sheave 30B C09= A05, A06 or A C09= B03, B04, B05, B06, B08 or B C09= B07 not used not used C09= B0 not used not used C09= C0, C02, C03, C04, C05 or C Belt- Until 7/90 (original fan design) C09= A05, B04 or B C09= A not used C09= A07 or B C09= B not used C09= B not used C09= B not used C09= B07 not used not used C09= B08 not used not used C09= B09 not used not used C09= C0 or C C09= C02 or C not used C09= C04 not used not used C09= C05 not used not used Belt- After 7/90 (redesigned fan assembly) C09= A05, B04, B0, C02 or C C09= A not used C09= A07, B03 or C C09= B not used C09= B not used C09= B07 not used not used C09= B08 not used not used C09= B09 not used not used C09= C04 not used not used C09= C05 not used not used C09= C06 not used not used Fan Sheave- Until 7/90 (original fan design) C09= A05, A07, B03, B07, B08 or C C09= A06, B05, B0, C02 or C C09= B04, B09, C0 or C C09= B06 or C not used Fan Sheave-After 7/90 (redesigned fan assy) C09= A05, A07, B03, B07, B08 or C C09= A06, B05, B0, C02, C03, C C09= B04, B09, C0, C C09= B06 or C not used Fan Coil; SCB,SHB 08-30B/FCZA,FCZC,FCZH,FHZA,FHZC,FHZH Des. Rev. U 0/8 RPL /Page 30

31 Drive Components- Standard FCZC, FHZC S08, S2 Ref. Part FCZC FCZC Qty. No. 292 Description Motor Sheave S S Belt Fan Sheave Drive Components- Standard FCZC, FHZC S6, S20, S30 Ref. Part FCZC FCZC FCZC S30 FCZC S30 Qty. No. Description S6 S20 5/208/230/ 230/460/3 292 Motor Sheave Belt Fan Sheave Drive Components- Standard FCZH, FHZH S08, S2, S6 Ref. Part FCZH FCZH FCZH S6 FCZH S6 Qty. No. Description S08 S2 5/208/230/ 230/460/3 292 Motor Sheave Belt Fan Sheave Drive Components- Standard FCZH, FHZH S20, S30 Ref. Part FCZH S20 FCZH S20 FCZH S30 FCZH S30 Qty. No. Description 5/208/230/ 230/460/3 5/208/230/ 230/460/3 292 Motor Sheave Belt Fan Sheave Drive Components- Standard FCZA, FHZA S08- S30 Ref. Part FCZA FCZA FCZA Qty. No. Description S08 - S6 S20 S Motor Sheave Belt Fan Sheave Fan Coil; SCB,SHB 08-30B/FCZA,FCZC,FCZH,FHZA,FHZC,FHZH Des. Rev. U 0/8 RPL /Page 3

32 Critical Daikin Applied OEM Parts Are What Your HVAC Unit Needs! McQuay Large Capacity Fan Coil, Belt Drive SCB, SHB Vintage B Critical Components Unit Sizes Voltage Part Number Fan Motor Motor ALL ALL See Factory Supplied Motors Fan Housing and Wheel Fan Housing Assy 08 N/A Fan Housing Assy 2 N/A Fan Housing Assy 6 N/A Fan Housing Assy 20 N/A Fan Housing Assy 30 N/A Fan Wheel 08 N/A Fan Wheel 2 N/A Fan Wheel 6 N/A Fan Wheel 20 N/A Fan Wheel 30 N/A Call Your Local Daikin Applied Parts Distributor For All Your Parts Needs. To Locate A Distributor, Go To or Call PARTS Rev. U 0/208 CPL Page of 2

33 Critical Daikin Applied OEM Parts Are What Your HVAC Unit Needs! McQuay Large Capacity Fan Coil, Belt Drive FCZA, FCZC, FCZH, FHZA, FHZC, FHZH S08-S30 Design A () Critical Components Unit Size Voltage Part Number Fan Motor Motor, /3HP S08 5/ /60/ Motor, /3HP S08 230/460/60/ Motor, /2HP S2, S6 5/ /60/ Motor, /2HP S2, S6 230/460/60/ Motor, 3/4HP S20 5/ /60/ Motor, 3/4HP S20 230/460/60/ Motor,.0HP S30 5/ /60/ Motor,.0HP S30 230/460/60/ Motor, 3/4HP S08, S2 5/ /60/ Motor, 3/4HP S08, S2 230/460/60/ Motor,.0HP S6 5/ /60/ Motor,.0HP S6 230/460/60/ Motor,.5HP S20, S30 5/ /60/ Motor,.5HP S20, S30 230/460/60/ Fan Housing and Wheel Fan Housing Assy S08 N/A Fan Housing Assy S2 N/A Fan Housing Assy S6 N/A Fan Housing Assy S20 N/A Fan Housing Assy S30 N/A Fan Wheel S08 N/A Fan Wheel S2 N/A Fan Wheel S6 N/A Fan Wheel S20 N/A Fan Wheel S30 N/A Call Your Local Daikin Applied Parts Distributor For All Your Parts Needs. To Locate A Distributor, Go To or Call PARTS Rev. U 0/208 CPL Page 2 of 2

McQuay. Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage B. FSCD, FSHD Design A (1)

McQuay. Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage B. FSCD, FSHD Design A (1) Replacement Parts List No. 055236500 Revision J 07/207 McQuay Large Capacity Fan Coil Direct Drive SCD, SHD 06-20 Vintage B FSCD, FSHD 06-20 Design A () To find your Daikin Applied parts distributor, call

More information

McQuay. Seasonmaker Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage A. Last Manufactured: 1986

McQuay. Seasonmaker Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage A. Last Manufactured: 1986 Replacement Parts List No. 47650300 Rev. A 09/205 McQuay Seasonmaker Large Capacity Fan Coil Direct Drive SCD, SHD 06-20 Vintage A Last Manufactured: 986 To find your Daikin Applied parts distributor,

More information

McQuay. Cabinet Unit Heater. CHB, CHF Vintage A. FCHB, FCHF Design A (1) Last Manufactured: 2010

McQuay. Cabinet Unit Heater. CHB, CHF Vintage A. FCHB, FCHF Design A (1) Last Manufactured: 2010 Replacement Parts List No. 055211700 Revision G 05/2017 McQuay Cabinet Unit Heater CHB, CHF 003-015 Vintage A FCHB, FCHF 03-15 Design A (1) Last Manufactured: 2010 To find your Daikin Applied parts distributor,

More information

Daikin McQuay. Large Capacity Fan Coil Belt Drive. HCBB, HHBB Design 1. Replacement Parts List No Revision E 03/2018

Daikin McQuay. Large Capacity Fan Coil Belt Drive. HCBB, HHBB Design 1. Replacement Parts List No Revision E 03/2018 Replacement s List No. 700024000 Revision E 03/2018 Daikin McQuay Large Capacity Fan Coil Belt Drive HCBB, HHBB 08-30 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit

More information

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision B 03/2016

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision B 03/2016 Replacement s List 70002400 Revision B 03/206 Daikin McQuay Large Capacity Fan Coil Direct Drive HCDB, HHDB 06-20 Design To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com

More information

McQuay. Seasonmaker Fan Coil. TSF, TSB, TSC Vintage C. Last Manufactured: Replacement Parts List No Revision D 09/2016

McQuay. Seasonmaker Fan Coil. TSF, TSB, TSC Vintage C. Last Manufactured: Replacement Parts List No Revision D 09/2016 Replacement Parts List No. 055211000 Revision D 09/2016 McQuay Seasonmaker Fan Coil TSF, TSB, TSC 021-151 Vintage C Last Manufactured: 1989 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision C 03/2018

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision C 03/2018 Replacement s List 700024100 Revision C 03/2018 Daikin McQuay Large Capacity Fan Coil Direct Drive HCDB, HHDB 06-20 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit

More information

McQuay Climate Control Singer

McQuay Climate Control Singer Replacement Parts List No. 55205400 Rev. B 09/2015 McQuay Climate Control Singer Large Vertical Water Source Heat Pump LGP, LHP, LWP 18, 22 Vintage A Last Manufactured: 1989 To find your Daikin Applied

More information

McQuay. Water Source Heat Pump. HPH, HPV Vintage A, B. Last Manufactured: Replacement Parts List No Revision B 05/2012

McQuay. Water Source Heat Pump. HPH, HPV Vintage A, B. Last Manufactured: Replacement Parts List No Revision B 05/2012 Replacement Parts List No. 055211500 Revision B 05/2012 McQuay Water Source Heat Pump HPH, HPV 009-059 Vintage A, B Last Manufactured: 1986 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. EnerSaver Packaged Terminal Air Conditioner/Heat Pump. PNES; PNHS Design C (3)

Daikin McQuay. EnerSaver Packaged Terminal Air Conditioner/Heat Pump. PNES; PNHS Design C (3) Replacement Parts List No. 700018700 Revision E 04/2015 Daikin McQuay EnerSaver Packaged Terminal Air Conditioner/Heat Pump PNES; PNHS 009-015 Design C (3) To find your Daikin Applied parts distributor,

More information

McQuay. HiLine Fan Coil. HSB Vintage B. Last Manufactured: Replacement Parts List No Revision C 09/2016

McQuay. HiLine Fan Coil. HSB Vintage B. Last Manufactured: Replacement Parts List No Revision C 09/2016 Replacement Parts List No. 055211200 Revision C 09/2016 McQuay HiLine Fan Coil HSB 030-120 Vintage B Last Manufactured: 1990 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit

More information

McQuay. Incremental. MEK, MHK Vintage A. PKES, PKHS, PRKC, PRKH Design A (1) Replacement Parts List No Revision G 07/2017

McQuay. Incremental. MEK, MHK Vintage A. PKES, PKHS, PRKC, PRKH Design A (1) Replacement Parts List No Revision G 07/2017 Replacement Parts List No. 057110000 Revision G 07/2017 McQuay Incremental MEK, MHK 019-022 Vintage A PKES, PKHS, PRKC, PRKH 019-022 Design A (1) To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Seasonmaker Horizontal Fan Coil. TSC Vintage G. Last Manufactured: Replacement Parts List No Revision C 08/2016

McQuay. Seasonmaker Horizontal Fan Coil. TSC Vintage G. Last Manufactured: Replacement Parts List No Revision C 08/2016 Replacement Parts List 057117500 Revision C 08/2016 McQuay Seasonmaker Horizontal Fan Coil TSC 021-121 Vintage G Last Manufactured: 1997 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay Climate Control. Horizontal Water Source Heat Pump. CC, CG, CW Vintage C, D. Last Manufactured: 1986

McQuay Climate Control. Horizontal Water Source Heat Pump. CC, CG, CW Vintage C, D. Last Manufactured: 1986 Replacement Parts List No. 05520400 Revision D 01/2017 McQuay Climate Control Horizontal Water Source Heat Pump CC, CG, CW 0750-1000 Vintage C, D Last Manufactured: 1986 To find your Daikin Applied parts

More information

McQuay. Incremental. PFEC, PFES, PFHC, PFHS Suite II, 2 Motor 007, 009, 012, 015 Designs A(1), B(2) Last Manufactured: 2001

McQuay. Incremental. PFEC, PFES, PFHC, PFHS Suite II, 2 Motor 007, 009, 012, 015 Designs A(1), B(2) Last Manufactured: 2001 Replacement Parts List 110505300 Revision G 07/2016 McQuay Incremental PFEC, PFES, PFHC, PFHS Suite II, 2 Motor 007, 009, 012, 015 Designs A(1), B(2) Last Manufactured: 2001 To find your Daikin Applied

More information

McQuay. Thinline Vertical Fan Coil Floor Mounted. TSF Vintage G. Last Manufactured: 1997

McQuay. Thinline Vertical Fan Coil Floor Mounted. TSF Vintage G. Last Manufactured: 1997 Replacement Parts List No. 057117400 Revision F 08/2016 McQuay Thinline Vertical Fan Coil Floor Mounted TSF 021-121 Vintage G Last Manufactured: 1997 To find your Daikin Applied parts distributor, call

More information

Daikin McQuay. Incremental. Suite II, 2 Motor PDES Design C (3) Last Manufactured: 2008

Daikin McQuay. Incremental. Suite II, 2 Motor PDES Design C (3) Last Manufactured: 2008 Replacement Parts List 700018500 Revision B 02/2012 Daikin McQuay Incremental Suite II, 2 Motor PDES 009-015 Design C (3) Last Manufactured: 2008 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Console Water Source Heat Pump. European Unit WWME, WWMJ, WWMK, WWML Designs A, B (1, 2) Last Manufactured: 2004

McQuay. Console Water Source Heat Pump. European Unit WWME, WWMJ, WWMK, WWML Designs A, B (1, 2) Last Manufactured: 2004 Replacement Parts List 110502500 Revision C 02/2017 McQuay Console Water Source Heat Pump European Unit WWME, WWMJ, WWMK, WWML 007-015 Designs A, B (1, 2) Last Manufactured: 2004 To find your Daikin Applied

More information

McQuay. Enfinity Ceiling Mounted Water Source Heat Pump. WCCH, WCCW 019, 024 Design 1. Last Manufactured: 2008

McQuay. Enfinity Ceiling Mounted Water Source Heat Pump. WCCH, WCCW 019, 024 Design 1. Last Manufactured: 2008 Replacement Parts List No. 700013300 Revision A 05/2017 McQuay Enfinity Ceiling Mounted Water Source Heat Pump WCCH, WCCW 019, 024 Design 1 Last Manufactured: 2008 To find your Daikin Applied parts distributor,

More information

McQuay. Reciprocating Condensing Unit. ALP Vintage C. Last Manufactured: Replacement Parts List No Revision W 10/2017

McQuay. Reciprocating Condensing Unit. ALP Vintage C. Last Manufactured: Replacement Parts List No Revision W 10/2017 Replacement Parts List No. 700015000 Revision W 10/2017 McQuay Reciprocating Condensing Unit ALP 013-230 Vintage C Last Manufactured: 2002 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Water Source Heat Pump Replacement Chassis. VF Vintage H. Last Manufactured: 1992

McQuay. Water Source Heat Pump Replacement Chassis. VF Vintage H. Last Manufactured: 1992 Replacement Parts List No. 110502800 Revision A 02/2006 McQuay Water Source Heat Pump Replacement Chassis VF 100-330 Vintage H Last Manufactured: 1992 To find your Daikin Applied parts distributor, call

More information

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 007, 009, 012 Design 4. Replacement Parts List No Revision L 02/2018

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 007, 009, 012 Design 4. Replacement Parts List No Revision L 02/2018 Replacement Parts List No. 700016100 Revision L 02/2018 Daikin McQuay Enfinity Horizontal Water Source Heat Pump WCCH, WCCW 007, 009, 012 Design 4 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Enfinity Horizontal Water Source Heat Pump. WCRH, WCRW 007, 009, 012 Design 1. Replacement Parts List No Revision B 02/2018

McQuay. Enfinity Horizontal Water Source Heat Pump. WCRH, WCRW 007, 009, 012 Design 1. Replacement Parts List No Revision B 02/2018 Replacement Parts List No. 700011100 Revision B 02/2018 McQuay Enfinity Horizontal Water Source Heat Pump WCRH, WCRW 007, 009, 012 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay Air-Cooled Reciprocating Chiller ALR

McQuay Air-Cooled Reciprocating Chiller ALR Replacement Parts List No. 057115200 Revision S 07/2015 McQuay Air-Cooled Reciprocating Chiller ALR Sizes 010-185 Vintage D Last Manufactured: 2000 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

ComfortPac 42 x 16. PTAC, PTHP Sizes Design C (3) Replacement Parts List No Rev. J 2/2012

ComfortPac 42 x 16. PTAC, PTHP Sizes Design C (3) Replacement Parts List No Rev. J 2/2012 Replacement Parts List No. 700006200 Rev. J 2/2012 ComfortPac 42 x 16 PTAC, PTHP Sizes 07- Design C (3) To find your McQuay parts distributor, call 1-800-377-2787 or visit www.mcquay.com Table of Contents

More information

McQuay Climate Control. Water Source Heat Pump. CC, CG Vintage E, F, G. Last Manufactured: 1986

McQuay Climate Control. Water Source Heat Pump. CC, CG Vintage E, F, G. Last Manufactured: 1986 Replacement Parts List No. 110508600 Revision C 12/2008 McQuay Climate Control Water Source Heat Pump CC, CG 750-1000 Vintage E, F, G Last Manufactured: 1986 To find your Daikin Applied parts distributor,

More information

Daikin McQuay. Thinline Horizontal Fan Coils and Cabinet Unit Heaters. FCHC, FCHH, FCHR FHHC, FHHH, FHHR 02, 03, 04, 06, 08, 10, 12 Design 1

Daikin McQuay. Thinline Horizontal Fan Coils and Cabinet Unit Heaters. FCHC, FCHH, FCHR FHHC, FHHH, FHHR 02, 03, 04, 06, 08, 10, 12 Design 1 Replacement Parts List No. 700026400 Revision N 01/2018 Daikin McQuay Thinline Horizontal Fan Coils and Cabinet Unit Heaters FCHC, FCHH, FCHR FHHC, FHHH, FHHR 02, 03, 04, 06, 08, 10, 12 Design 1 To find

More information

McQuay. Central Station Air Handlers Low Pressure. LHD, LYF, LSL, LML, LWL Vintage C. LML, LSB Vintage E. Last Manufactured: 1999

McQuay. Central Station Air Handlers Low Pressure. LHD, LYF, LSL, LML, LWL Vintage C. LML, LSB Vintage E. Last Manufactured: 1999 Replacement Parts List No. 055222600 Revision F 11/2011 McQuay Central Station Air Handlers Low Pressure LHD, LYF, LSL, LML, LWL 103-228 Vintage C LML, LSB 106-111 Vintage E Last Manufactured: 1999 To

More information

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage C. Last Manufactured: 1984

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage C. Last Manufactured: 1984 Replacement Parts List No. 055222700 Revision D 0/205 McQuay Central Station Air Handler LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL 37-72 Vintage C Last Manufactured: 984 To find your Daikin Applied parts

More information

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 030, 036, 042 Design 1. Replacement Parts List No Revision B 10/2016

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 030, 036, 042 Design 1. Replacement Parts List No Revision B 10/2016 Replacement Parts List No. 700011300 Revision B 10/2016 McQuay Ceiling Mounted Water Source Heat Pump WCRH, WCRW 030, 036, 042 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage D. LML, LSB, MMM, MSB Vintage E

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage D. LML, LSB, MMM, MSB Vintage E Replacement Parts List No. 046902100 Revision D 01/2015 McQuay Central Station Air Handler LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL 137-172 Vintage D LML, LSB, MMM, MSB 137-172 Vintage E Last Manufactured:

More information

Daikin McQuay. Enfinity Vertical Water Source Heat Pump. WVFC, WVFW Design 1. Replacement Parts List No Revision S 01/2018

Daikin McQuay. Enfinity Vertical Water Source Heat Pump. WVFC, WVFW Design 1. Replacement Parts List No Revision S 01/2018 Replacement Parts List No. 700012100 Revision S 01/2018 Daikin McQuay Enfinity Vertical Water Source Heat Pump WVFC, WVFW 009-070 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 042, 048, 060, 070 Design 5

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 042, 048, 060, 070 Design 5 Replacement Parts List No. 700027900 Revision M 09/2018 Daikin McQuay Enfinity Horizontal Water Source Heat Pump WCCH, WCCW 042, 048, 060, 070 Design 5 To find your Daikin Applied parts distributor, call

More information

McQuay Central Station Air Handler Medium Pressure MSL

McQuay Central Station Air Handler Medium Pressure MSL Replacement Parts List No. 55223700 Revision B 09/2016 McQuay Central Station Air Handler Medium Pressure MSL 190 Vintage C Last Manufactured: 1998 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 048, 060, 070 Design 1. Replacement Parts List No Revision C 10/2016

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 048, 060, 070 Design 1. Replacement Parts List No Revision C 10/2016 Replacement Parts List No. 700011400 Revision C 10/2016 McQuay Ceiling Mounted Water Source Heat Pump WCRH, WCRW 048, 060, 070 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. Air- Cooled Condenser. ACH, ACX, ACL Vintage A. Replacement Parts List No Revision C 10/2016

Daikin McQuay. Air- Cooled Condenser. ACH, ACX, ACL Vintage A. Replacement Parts List No Revision C 10/2016 Replacement Parts List No. 700023300 Revision C 0/206 Daikin McQuay Air- Cooled Condenser ACH, ACX, ACL 04-225 Vintage A To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com

More information

McQuay. Ceiling Concealed Water Source Heat Pump. CCH, CCG, CCW 015, 019 Vintage A. Last Manufactured: 1995

McQuay. Ceiling Concealed Water Source Heat Pump. CCH, CCG, CCW 015, 019 Vintage A. Last Manufactured: 1995 Replacement Parts List No. 55235700 Revision C 08/2017 McQuay Ceiling Concealed Water Source Heat Pump CCH, CCG, CCW 015, 019 Vintage A Last Manufactured: 1995 To find your Daikin Applied parts distributor,

More information

Daikin. PreciseLine Horizontal Large Capacity Blower Coil. BCHD Design 1. Replacement Parts List No Revision A 03/2019

Daikin. PreciseLine Horizontal Large Capacity Blower Coil. BCHD Design 1. Replacement Parts List No Revision A 03/2019 Replacement Parts List No. 700053700 Revision A 03/2019 Daikin PreciseLine Horizontal Large Capacity Blower Coil BCHD 030-050 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

ComfortPac 42 x 16. PTAC, PTHP Sizes Vintages B and B+ (2) Replacement Parts List No Rev. P 1/2012

ComfortPac 42 x 16. PTAC, PTHP Sizes Vintages B and B+ (2) Replacement Parts List No Rev. P 1/2012 Replacement Parts List No. 110511900 Rev. P 1/2012 ComfortPac 42 x 16 PTAC, PTHP Sizes 07-15 Vintages B and B+ (2) To find your McQuay parts distributor, call 1-800-377-2787 or visit www.mcquay.com Table

More information

Daikin McQuay. Enfinity Vertical Water Source Heat Pump. WVFC, WVFW Design 1. Replacement Parts List No Revision V 11/2018

Daikin McQuay. Enfinity Vertical Water Source Heat Pump. WVFC, WVFW Design 1. Replacement Parts List No Revision V 11/2018 Replacement Parts List No. 700012100 Revision V 11/2018 Daikin McQuay Enfinity Vertical Water Source Heat Pump WVFC, WVFW 009-070 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1 Replacement Parts List No. 700024700 Revision M 11/2017 Daikin Daikin McQuay SmartSource Single Stage Horizontal Water Source Heat Pump WGSH 007, 009, 012 Design 1 To find your Daikin Applied parts distributor,

More information

McQuay. Thinline Vertical Fan Coil. FCVC, FCVH, FCVS FHVC, FHVH, FHVS, FHWC 02, 03, 04, 06, 08, 10, 12 Design 1

McQuay. Thinline Vertical Fan Coil. FCVC, FCVH, FCVS FHVC, FHVH, FHVS, FHWC 02, 03, 04, 06, 08, 10, 12 Design 1 Replacement Parts List No. 700015400 Revision R 03/2019 McQuay Thinline Vertical Fan Coil FCVC, FCVH, FCVS FHVC, FHVH, FHVS, FHWC 02, 03, 04, 06, 08, 10, 12 Design 1 To find your Daikin Applied parts distributor,

More information

Daikin Daikin McQuay. SmartSource Single Stage Vertical Water Source Heat Pump. WGSV 007, 009, 012 Design 1

Daikin Daikin McQuay. SmartSource Single Stage Vertical Water Source Heat Pump. WGSV 007, 009, 012 Design 1 Replacement Parts List No. 700029600 Revision L 11/2017 Daikin Daikin McQuay SmartSource Single Stage Vertical Water Source Heat Pump WGSV 007, 009, 012 Design 1 To find your Daikin Applied parts distributor,

More information

Daikin. SmartSource Compact Vertical Water Source Heat Pump. WGCV 048, 060, 070 Design 1. Replacement Parts List No Revision D 01/2018

Daikin. SmartSource Compact Vertical Water Source Heat Pump. WGCV 048, 060, 070 Design 1. Replacement Parts List No Revision D 01/2018 Replacement Parts List No. 700052400 Revision D 01/2018 Daikin SmartSource Compact Vertical Water Source Heat Pump WGCV 048, 060, 070 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW Design 2. Replacement Parts List No Revision F 04/2018

Daikin. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW Design 2. Replacement Parts List No Revision F 04/2018 Replacement Parts List No. 700050900 Revision F 04/2018 Daikin Enfinity Horizontal Water Source Heat Pump WCCH, WCCW 072-120 Design 2 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1 Replacement Parts List No. 700024700 Revision O 10/2018 Daikin Daikin McQuay SmartSource Single Stage Horizontal Water Source Heat Pump WGSH 007, 009, 012 Design 1 To find your Daikin Applied parts distributor,

More information

McQuay. Vertical Water Source Heat Pump. FCV, FCG & FCW 036 & 042 Vintage B. WFDD, WFDE, WFDG, WFDL WFDS, WFME, WFMS 036 & 042 Design A (1)

McQuay. Vertical Water Source Heat Pump. FCV, FCG & FCW 036 & 042 Vintage B. WFDD, WFDE, WFDG, WFDL WFDS, WFME, WFMS 036 & 042 Design A (1) Replacement Parts List 057103500 Revision P 03/2016 McQuay Vertical Water Source Heat Pump FCV, FCG & FCW 036 & 042 Vintage B WFDD, WFDE, WFDG, WFDL WFDS, WFME, WFMS 036 & 042 Design A (1) WFDA, WFDD,

More information

Westinghouse. Rooftop Heating and Cooling. IK 180 Vintage 0, 1, 2, 3, 4. Last Manufactured: 1975

Westinghouse. Rooftop Heating and Cooling. IK 180 Vintage 0, 1, 2, 3, 4. Last Manufactured: 1975 Replacement Parts List No. 055227700 Revision A 03/2003 Westinghouse Rooftop Heating and Cooling IK 180 Vintage 0, 1, 2, 3, 4 Last Manufactured: 1975 To find your Daikin Applied parts distributor, call

More information

McQuay. Console Water Source Heat Pump. WMH, WMG, WMK, WCH, WCG 007, 009,012 Vintage B. Last Manufactured: 1998

McQuay. Console Water Source Heat Pump. WMH, WMG, WMK, WCH, WCG 007, 009,012 Vintage B. Last Manufactured: 1998 Replacement Parts List No. 057101600 Revision E 06/2015 McQuay Console Water Source Heat Pump WMH, WMG, WMK, WCH, WCG 007, 009,012 Vintage B Last Manufactured: 1998 To find your Daikin Applied parts distributor,

More information

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW Design 1. Replacement Parts List No Revision I 12/2015

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW Design 1. Replacement Parts List No Revision I 12/2015 Replacement Parts List No. 700014800 Revision I 12/2015 Daikin McQuay Vertical Stack Water Source Heat Pump WVHC, WVHF, WVHW 009-036 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Westinghouse. Rooftop Heating and Cooling. IK 300 Vintage 0, 1, 2, 3, 4, 5. Last Manufactured: 1975

Westinghouse. Rooftop Heating and Cooling. IK 300 Vintage 0, 1, 2, 3, 4, 5. Last Manufactured: 1975 Replacement Parts List No. 055227900 Revision A 03/2003 Westinghouse Rooftop Heating and Cooling IK 300 Vintage 0,, 2, 3, 4, 5 Last Manufactured: 975 To find your Daikin Applied parts distributor, call

More information

McQuay. Water-Cooled Screw Chiller. PFS Vintage B. Last Manufactured: Replacement Parts List No Revision D 02/2017

McQuay. Water-Cooled Screw Chiller. PFS Vintage B. Last Manufactured: Replacement Parts List No Revision D 02/2017 Replacement Parts List No. 057118200 Revision D 02/2017 McQuay Water-Cooled Screw Chiller PFS 150-215 Vintage B Last Manufactured: 1997 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 015, 019 Design 1

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 015, 019 Design 1 Replacement Parts List No. 700024800 Revision N 10/2018 Daikin Daikin McQuay SmartSource Single Stage Horizontal Water Source Heat Pump WGSH 015, 019 Design 1 To find your Daikin Applied parts distributor,

More information

McQuay. Vertical Water Source Heat Pump. FCV, FCG, FCW Vintage B. WFAS,WFDD,WFDE,WFDL,WFDS,WFME,WFMS Design A (1)

McQuay. Vertical Water Source Heat Pump. FCV, FCG, FCW Vintage B. WFAS,WFDD,WFDE,WFDL,WFDS,WFME,WFMS Design A (1) Replacement Parts List No. 057103200 Revision K 03/2018 McQuay Vertical Water Source Heat Pump FCV, FCG, FCW 007-012 Vintage B WFAS,WFDD,WFDE,WFDL,WFDS,WFME,WFMS 007-012 Design A (1) WFAE,WFAS,WFDD,WFDE,

More information

McQuay. Evaporative Condenser Cooled Chiller. EGR Vintage A. Last Manufactured: Replacement Parts List No Revision B 07/2010

McQuay. Evaporative Condenser Cooled Chiller. EGR Vintage A. Last Manufactured: Replacement Parts List No Revision B 07/2010 Replacement Parts List No. 700015100 Revision B 07/2010 McQuay Evaporative Condenser Cooled Chiller EGR 060-240 Vintage A Last Manufactured: 2004 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Air-Cooled Global Reciprocating Condensing Unit. ACR Vintage A. Last Manufactured: 2003

McQuay. Air-Cooled Global Reciprocating Condensing Unit. ACR Vintage A. Last Manufactured: 2003 Replacement Parts List No. 110504800 Revision G 04/2016 McQuay Air-Cooled Global Reciprocating Condensing Unit ACR 060-120 Vintage A Last Manufactured: 2003 To find your Daikin Applied parts distributor,

More information

Daikin McQuay. VAV Air Terminal Unit MQ FCI6, FVI5, THI5. Replacement Parts List No Revision J 07/2017

Daikin McQuay. VAV Air Terminal Unit MQ FCI6, FVI5, THI5. Replacement Parts List No Revision J 07/2017 Replacement Parts List No. 700020000 Revision J 07/2017 Daikin McQuay VAV Air Terminal Unit MQ FCI6, FVI5, THI5 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.daikinapplied.com

More information

McQuay. Steam/Hot Water Unit Heater. UDH Vintage C. Last Manufactured: Replacement Parts List No Revision New 07/2010

McQuay. Steam/Hot Water Unit Heater. UDH Vintage C. Last Manufactured: Replacement Parts List No Revision New 07/2010 Replacement Parts List No. 700018100 Revision New 07/2010 McQuay Steam/Hot Water Unit Heater UDH 040-960 Vintage C Last Manufactured: 1992 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. SeasonMaster Central Station Air Handler. HSH, HMH, HWL Vintage B Vintage C. Last Manufactured: 1984

McQuay. SeasonMaster Central Station Air Handler. HSH, HMH, HWL Vintage B Vintage C. Last Manufactured: 1984 Replacement Parts List No. 055223300 Revision B 06/2018 McQuay SeasonMaster Central Station Air Handler HSH, HMH, HWL 137-164 Vintage B 117-128 Vintage C Last Manufactured: 1984 To find your Daikin Applied

More information

McQuay. Console Water Source Heat Pump. CWC, CWG, CWH, CWJ, CWK Vintage B. Last Manufactured: 1994

McQuay. Console Water Source Heat Pump. CWC, CWG, CWH, CWJ, CWK Vintage B. Last Manufactured: 1994 Replacement Parts List No. 057101700 Revision B 02/2017 McQuay Console Water Source Heat Pump CWC, CWG, CWH, CWJ, CWK 015-019 Vintage B Last Manufactured: 1994 To find your Daikin Applied parts distributor,

More information

McQuay. Console Water Source Heat Pump. Replacement Parts List No Revision Q 07/2016

McQuay. Console Water Source Heat Pump. Replacement Parts List No Revision Q 07/2016 Replacement Parts List 110502400 Revision Q 07/2016 McQuay Console Water Source Heat Pump WWAF,WWAG,WWAH,WWAS,WWAX,WWCQ WWDA,WWDB,WWDD,WWDE,WWDF,WWDG,WWDH, WWDJ,WWDN,WWDS,WWFQ,WWLA,WWLB,WWLC,WWLL, WWMA,WWMB,WWMC,WWMD,WWMF,WWMG,WWMH,

More information

Centrifugal Chiller. PF/PFH Size: 063. Replacement Parts List No Revision V 05/2012

Centrifugal Chiller. PF/PFH Size: 063. Replacement Parts List No Revision V 05/2012 Replacement Parts List No. 057113900 Revision V 05/2012 Centrifugal Chiller PF/PFH Size: 063 To find your Daikin McQuay parts distributor, call 1-800-377-2787 or visit www.daikinmcquay.com Contents Parts

More information

McQuay Climate Control Singer. Rooftop Unit. ER, R 080 Vintage A, B, C, D. Last Manufactured: 1996

McQuay Climate Control Singer. Rooftop Unit. ER, R 080 Vintage A, B, C, D. Last Manufactured: 1996 Replacement Parts List No. 779200300 Revision C 04/2011 McQuay Climate Control Singer Rooftop Unit ER, R 080 Vintage A, B, C, D Last Manufactured: 1996 To find your Daikin Applied parts distributor, call

More information

Daikin McQuay. Roofpak Applied Rooftop Air Handler. RDS Size 708 Vintage B. Replacement Parts List No Revision F 03/2018

Daikin McQuay. Roofpak Applied Rooftop Air Handler. RDS Size 708 Vintage B. Replacement Parts List No Revision F 03/2018 Replacement Parts List No. 047652600 Revision F 03/208 Daikin McQuay Roofpak Applied Rooftop Air Handler RDS Size 708 Vintage B To find your Daikin Applied parts distributor, call -800-377-2787 or visit

More information

McQuay Climate Control Singer. Rooftop Unit. ER, R 250 Vintage C, D. Last Manufactured: Replacement Parts List No Revision C 04/2002

McQuay Climate Control Singer. Rooftop Unit. ER, R 250 Vintage C, D. Last Manufactured: Replacement Parts List No Revision C 04/2002 Replacement Parts List No. 779200800 Revision C 04/2002 McQuay Climate Control Singer Rooftop Unit ER, R 250 Vintage C, D Last Manufactured: 1996 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

REPAIR PARTS. DAR090/120 Commercial Air Handlers DAR0904AA DAR1204AA. This manual is to be used by qualified technicians only.

REPAIR PARTS. DAR090/120 Commercial Air Handlers DAR0904AA DAR1204AA. This manual is to be used by qualified technicians only. DAR090/120 Commercial Air Handlers DAR0904AA DAR1204AA REPAIR PARTS This manual is to be used by qualified technicians only. 2013 Daikin Company, L.P. 5151 San Felipe St., Suite 500 Houston, TX 77056 June

More information

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW 036 Design 2. Replacement Parts List No Revision A 12/2015

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW 036 Design 2. Replacement Parts List No Revision A 12/2015 Replacement Parts List No. 700050700 Revision A 12/2015 Daikin McQuay Vertical Stack Water Source Heat Pump WVHC, WVHF, WVHW 036 Design 2 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW Design 3 009, 012 Design 4

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW Design 3 009, 012 Design 4 Replacement Parts List No. 700050500 Revision G 07/2018 Daikin McQuay Vertical Stack Water Source Heat Pump WVHC, WVHF, WVHW 009-036 Design 3 009, 012 Design 4 To find your Daikin Applied parts distributor,

More information

McQuay. Classroom Unit Ventilator Ceiling Mounted. UAHB, UAHF, UAHR, UAHV 07, 10, 13, 15, 20 Design F (6)

McQuay. Classroom Unit Ventilator Ceiling Mounted. UAHB, UAHF, UAHR, UAHV 07, 10, 13, 15, 20 Design F (6) Replacement Parts List No. 70002300 Revision J 03/207 McQuay Classroom Unit Ventilator Ceiling Mounted UAHB, UAHF, UAHR, UAHV 07, 0, 3, 5, 20 Design F (6) To find your Daikin Applied parts distributor,

More information

McQuay. Thermal Systems Absorption Chiller ME, MF Vintage A. Last Manufactured: Replacement Parts List No New 05/2001

McQuay. Thermal Systems Absorption Chiller ME, MF Vintage A. Last Manufactured: Replacement Parts List No New 05/2001 Replacement Parts List No. 1105050 New 05/2001 McQuay Thermal Systems Absorption Chiller ME, MF 21-33 Vintage A Last Manufactured: 1997 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm Product Data 42BH System Fan Coil 800 to 4000 Cfm Satisfy All Your Design Requirements with Carrier s Versatile 42BH Fan Coil Unit A selection of 6 sizes covers capacities from 800 to 4000 cfm Choice of

More information

McQuay Climate Control. Commercial Unitary Rooftop. CUR Vintage F. Last Manufactured: 1996

McQuay Climate Control. Commercial Unitary Rooftop. CUR Vintage F. Last Manufactured: 1996 Replacement s List No. 055236800 Revision C 11/2016 McQuay Climate Control Commercial Unitary Rooftop CUR 075-150 Vintage F Last Manufactured: 1996 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay Climate Control Singer. Rooftop Unit. ER, R 160 Vintage A, B, C, D. Last Manufactured: 1996

McQuay Climate Control Singer. Rooftop Unit. ER, R 160 Vintage A, B, C, D. Last Manufactured: 1996 Replacement Parts List No. 779200600 Revision B 07/2007 McQuay Climate Control Singer Rooftop Unit ER, R 160 Vintage A, B, C, D Last Manufactured: 1996 To find your Daikin Applied parts distributor, call

More information

Toll Free Phone, (US & Canada): (800) Toll Free Fax, (US & Canada): (800)

Toll Free Phone, (US & Canada): (800) Toll Free Fax, (US & Canada): (800) Toll Free Phone, (US & Canada): (800) 427-6668 Toll Free Fax, (US & Canada): (800) 36-7745 http://www.garland-group.com G_EO_PL_CONVECTION_MCOESED0FROM0004CJ000 (Rev2) Explanation of Serial Number Identification

More information

Commercial-in-Confidence Ashton Old Baths Financial Model - Detailed Cashflow

Commercial-in-Confidence Ashton Old Baths Financial Model - Detailed Cashflow Year 0 1 2 3 4 5 6 7 8 9 10 11 12 13 Oct-16 Nov-16 Dec-16 Jan-17 Feb-17 Mar-17 Apr-17 May-17 Jun-17 Jul-17 Aug-17 Sep-17 Oct-17 2,038 2,922 4,089 4,349 6,256 7,124 8,885 8,885 8,885 8,885 8,885 8,885 9,107

More information

McQuay Westinghouse. Centrifugal Chiller PF, PFH 063. Last Manufactured: Replacement Parts List No Revision AB 06/2018

McQuay Westinghouse. Centrifugal Chiller PF, PFH 063. Last Manufactured: Replacement Parts List No Revision AB 06/2018 Replacement Parts List No. 57113900 Revision AB 06/2018 McQuay Westinghouse Centrifugal Chiller PF, PFH 063 Last Manufactured: 2002 To find your Daikin Applied parts distributor, call 1-800-377-2787 or

More information

Summit Electric Convection Ovens

Summit Electric Convection Ovens Summit Electric Convection Ovens models SUME-00, SUME-200 Phone (US & Canada): 800 427 6668 Fax (US & Canada): 800 36 7745 www.garland-group.com U_GO_PL_CONVECTION_SUME (Rev 5) Quality Factory Replacement

More information

McQuay. Two-Stage Centrifugal Chiller WTC 700. Replacement Parts List No Revision B 07/2017

McQuay. Two-Stage Centrifugal Chiller WTC 700. Replacement Parts List No Revision B 07/2017 Replacement Parts List No. 700014000 Revision B 07/2017 McQuay Two-Stage Centrifugal Chiller WTC 700 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.daikinapplied.com Table

More information

Daikin McQuay. Destiny Indoor Air Handler. LAH Vintage A. Replacement Parts List No Revision T 10/2017

Daikin McQuay. Destiny Indoor Air Handler. LAH Vintage A. Replacement Parts List No Revision T 10/2017 Replacement Parts List No. 700004800 Revision T 10/2017 Daikin McQuay Destiny Indoor Air Handler LAH 002-030 Vintage A To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.daikinapplied.com

More information

AAF. Console Water Source Heat Pump. CWC, CWG, CWH, CWJ, CWK Vintage B. Last Manufactured: 1994

AAF. Console Water Source Heat Pump. CWC, CWG, CWH, CWJ, CWK Vintage B. Last Manufactured: 1994 Replacement Parts List No. 057101500 Revision B 02/2017 AAF Console Water Source Heat Pump CWC, CWG, CWH, CWJ, CWK 006-012 Vintage B Last Manufactured: 1994 To find your Daikin Applied parts distributor,

More information

McQuay. Self-Contained Unit Ventilator UAEQ 024, 036, 044, 054. UARQ, UERQ, UGRQ 024, 030, 040, 048 Design F (6)

McQuay. Self-Contained Unit Ventilator UAEQ 024, 036, 044, 054. UARQ, UERQ, UGRQ 024, 030, 040, 048 Design F (6) Replacement Parts List No. 70009600 Revision D 0/207 McQuay Self-Contained Unit Ventilator UAEQ 024, 036, 044, 054 UARQ, UERQ, UGRQ 024, 030, 040, 048 Design F (6) To find your Daikin Applied parts distributor,

More information

Submittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499]

Submittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499] BC--1.0 03-01-1 Belt Drive Blower Coil Unit, Basic Unit Discharge ARGT. 1 4. See page 1 for filter rack details. 5. Base rail is optional on he base unit. See page 13. Base rails must be used with mixing

More information

Complete HVAC Capability

Complete HVAC Capability Air Handling Units Brochure 1110 January 2006 Complete HVAC Capability MEA Horizontal Draw-Thru to Size 65 Vertical Draw-Thru to Size 50 1000 to 60,000 CFM Forward Curved or Airfoil Wheels Inlet Vane Option

More information

McQuay Climate Control Singer. Water Source Heat Pump. VF, VG, VP Vintage C. Last Manufactured: 1982

McQuay Climate Control Singer. Water Source Heat Pump. VF, VG, VP Vintage C. Last Manufactured: 1982 Replacement Parts List No. 055206500 Revision C 02/2017 McQuay Climate Control Singer Water Source Heat Pump VF, VG, VP 240-400 Vintage C Last Manufactured: 1982 To find your Daikin Applied parts distributor,

More information

McQuay. Seasonpak Reciprocating Chiller. WHR Vintage C. Last Manufactured: Replacement Parts List No Revision I 05/2016

McQuay. Seasonpak Reciprocating Chiller. WHR Vintage C. Last Manufactured: Replacement Parts List No Revision I 05/2016 Replacement Parts List No. 055224300 Revision I 05/2016 McQuay Seasonpak Reciprocating Chiller WHR 008-120 Vintage C Last Manufactured: 1998 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. Vertical Unit Ventilator. UAVS, UAVV, UAVR, UAVB Design F (6) Replacement Parts List No Revision P 10/2018

Daikin McQuay. Vertical Unit Ventilator. UAVS, UAVV, UAVR, UAVB Design F (6) Replacement Parts List No Revision P 10/2018 Replacement Parts List No. 70000500 Revision P 0/208 Daikin McQuay Vertical Unit Ventilator UAVS, UAVV, UAVR, UAVB 07-5 Design F (6) To find your Daikin Applied parts distributor, call -800-377-2787 or

More information

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL REPLACEMENT PARTS MANUAL PACKAGE HEAT PUMP Models: PH242-A PH363-A PH302-A PH363-B General Notes Revised and/or additional pages may be issued from time to time. A complete and current manual consists

More information

Parts Manual. PTAC PD Series (Electronic Controls) Packaged Terminal Air Conditioners Packaged Terminal Heat Pumps Serial Number LEAP and Later MODELS

Parts Manual. PTAC PD Series (Electronic Controls) Packaged Terminal Air Conditioners Packaged Terminal Heat Pumps Serial Number LEAP and Later MODELS Parts Manual PTAC PD Series (Electronic Controls) Packaged Terminal Air Conditioners Packaged Terminal Heat Pumps Serial Number LEAP and Later MODELS PDE07K**B-A PDE07R**B-A PDE09K**B-A PDE09R**B-A PDE12K**B-A

More information

Horizontal Series Fan Coil Technical Catalog

Horizontal Series Fan Coil Technical Catalog Horizontal Series Fan Coil Technical Catalog HCY Horizontal Hideaway 200 CFM to 200 CFM The Horizontal Hideaway (HCY) fan coil unit is designed specifically to meet the many varied requirements for a ceiling

More information

McQuay. Global Air-Cooled Scroll Chiller. AGZ Vintage A Two-circuit. Last Manufactured: 2005

McQuay. Global Air-Cooled Scroll Chiller. AGZ Vintage A Two-circuit. Last Manufactured: 2005 Replacement Parts List No. 057117900 Revision R 10/2016 McQuay Global Air-Cooled Scroll Chiller AGZ 030-065 Vintage A Two-circuit Last Manufactured: 2005 To find your Daikin Applied parts distributor,

More information

McQuay. Two-Stage Centrifugal Chiller WTC 500. Replacement Parts List No Revision A 10/2011

McQuay. Two-Stage Centrifugal Chiller WTC 500. Replacement Parts List No Revision A 10/2011 Replacement Parts List No. 700019800 Revision A 10/2011 McQuay Two-Stage Centrifugal Chiller WTC 500 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.daikinapplied.com Table

More information

PARTS LIST. Master Gas R Series Production Griddle Front Drain. CG - 24R / 36R / 48R / 60R / 72R (formerlly GAW) models.

PARTS LIST. Master Gas R Series Production Griddle Front Drain. CG - 24R / 36R / 48R / 60R / 72R (formerlly GAW) models. Master Gas R Series Production Griddle Front Drain models CG - 24R / 36R / 48R / 60R / 72R (formerlly GAW) CG-48R, shown with optional stand and casters PARTS LIST Parts & Service T (USA & Canada): 1 800

More information

Summit Series. Full Size Electric Convection Ovens. Parts List. Models SUME-100 SUME-200

Summit Series. Full Size Electric Convection Ovens. Parts List. Models SUME-100 SUME-200 Summit Series Full Size Electric Convection Ovens Parts List Models SUME-00 SUME-200 Document Number: U_EO_PL_CONVECTION_SUME00 rev 09 Updated 5/7 Units Built UPTO 3-MAR-20 Rating Plate Location Units

More information

nufacturing Company, L.P San Felipe, Suite 500

nufacturing Company, L.P San Felipe, Suite 500 Commercial 20 Ton Package Gas Units DCG2404003BAXAAA DCG2404003BXXXAA DCG2404004BXXXAA DCG2404004BXXXAB DCG2404007BXXXAA REPAIR PARTS nufacturing Company, L.P. 5151 San Felipe, Suite 500 www.amana-hac.com

More information

BUILD YOUR REPUTATION ON OURS. Horizontal Series FAN COIL TECHNICAL CATALOG

BUILD YOUR REPUTATION ON OURS. Horizontal Series FAN COIL TECHNICAL CATALOG BUILD YOUR REPUTATION ON OURS Horizontal Series FAN COIL TECHNICAL CATALOG TABLE OF CONTENTS 2 Table of Contents 3-4 Portfolio 5 Features & Benefits Unit Model Key 7 Ratings & Listings 8 Air Delivery 9

More information

REPAIR PARTS. DAT Commercial 2-Speed Air Handler. This manual is to be used by qualified technicians only. This manual replaces RP-D4022.

REPAIR PARTS. DAT Commercial 2-Speed Air Handler. This manual is to be used by qualified technicians only. This manual replaces RP-D4022. REPAIR PARTS DAT Commercial 2-Speed Air Handler DAT09043AA DAT09044AA DAT12043AA DAT12044AA nufacturing Company, L.P. 5151 San Felipe, Suite 500 This manual is to be used by qualified technicians only.

More information

AAF Herman Nelson. Classmate Conventional Unit Ventilator. AH 1-8 AV 1-6 Vintage A / No Vintage. Last Manufactured: 1990

AAF Herman Nelson. Classmate Conventional Unit Ventilator. AH 1-8 AV 1-6 Vintage A / No Vintage. Last Manufactured: 1990 Replacement Parts List 5702000 Revision R /207 AAF Herman Nelson Classmate Conventional Unit Ventilator AH -8 AV -6 Vintage A / No Vintage Last Manufactured: 990 To find your Daikin Applied parts distributor,

More information

Gas Convection Ovens UP TO

Gas Convection Ovens UP TO Gas Convection Ovens models SDG-, SDG-2 UP TO (serial#) 2052300xxxxx (date) 3-May-2 Phone (US & Canada): 800 427 6668 Fax (US & Canada): 800 36 7745 www.garland-group.com U_GO_PL_SUNFIRE_SDGSDG2 (Rev 8)

More information

WENDY S COMBO RANGE STW286A SERIES

WENDY S COMBO RANGE STW286A SERIES WENDY S COMBO RANGE STW286A SERIES Manufactured From June 16, 2005 PA R TS LI IS T Toll Free Phone, (US & Canada): (800) 427-6668 Toll Free Fax, (US & Canada): (800) 361-7745 http://www.garland-group.com

More information

nufacturing Company, L.P San Felipe, Suite 500

nufacturing Company, L.P San Felipe, Suite 500 REPAIR PARTS Commercial 10 Ton Package Cooling Units DCC1200304BHXBAA DCC120XXX3BXXXAA DCC120XXX4BXXXAA DCC120XXX4BXXXAB DCC120XXX7BXXXAA nufacturing Company, L.P. 5151 San Felipe, Suite 500 www.amana-hac.com

More information