1 Replacement Parts List No Revision R 10/2016 McQuay Global Air-Cooled Scroll Chiller AGZ Vintage A Two-circuit Last Manufactured: 2005 To find your Daikin Applied parts distributor, call or visit

2 Index Page Heading Description 3 Revision History Parts List Revisions 4, 5 Nomenclature Unit Serial Number and Unit Model Number Definitions 6-8 Compressors 6 Unit Compressors 208/230V 7 Unit Compressors 460V 8 Unit Compressors 575V 9-19 Power Panel 9 Diagrams Panel Layout, Latches, Catches and Hinges 10 Components- All Sizes Latches, Catches, Hinges, Ground Screw, Unit % Amp Draw, Ground Fault 11 Components- All Sizes Speedtrol Transformer, Phase Voltage Monitor, Fan Contactors and Fuses, Control Transformer and Fuses 12 Components- AGZ030 Contactors, Circuit Breakers, Power Block, Disconnect, Power Hub 13 Components- AGZ035 Contactors, Circuit Breakers, Power Block, Disconnect, Power Hub 14 Components- AGZ040 Contactors, Circuit Breakers, Power Block, Disconnect, Power Hub 15 Components- AGZ045 Contactors, Circuit Breakers, Power Block, Disconnect, Power Hub 16 Components- AGZ050 Contactors, Circuit Breakers, Power Block, Disconnect, Power Hub 17 Components- AGZ055 Contactors, Circuit Breakers, Power Block, Disconnect, Power Hub 18 Components- AGZ060 Contactors, Circuit Breakers, Power Block, Disconnect, Power Hub 19 Components- AGZ065 Contactors, Circuit Breakers, Power Block, Disconnect, Power Hub Control Panel- UNT Controls (C11= J**) 20 Diagram UNT Control Panel- Left Side 21 Components UNT Control Panel- Left Side 22 Diagram UNT Control Panel- Right Side 23 Components UNT Control Panel- Right Side 24 Zone Terminal Display All Sizes- Diagram and Components 25 Diagrams Unit Sensors, L.L. Soldenoid Valve Junction Box, Pressure Controls 26 Components Unit Sensors, L.L. Soldenoid Valve Junction Box, Pressure Controls Control Panel- MicroTech Controls (C11= M**) 27 Diagram MicroTech Control Panel- Left Side 28 Components MicroTech Control Panel- Left Side 29 Diagram MicroTech Control Panel- Right Side 30 Components MicroTech Control Panel- Right Side 31 Keypad Display All Sizes- Diagram and Components 32 Diagrams Unit Sensors, L.L. Soldenoid Valve Junction Box, Pressure Controls 33 Components Unit Sensors, L.L. Soldenoid Valve Junction Box, Pressure Controls 34 Speedtrol Components, Convenience Outlet Components, Gauges 34 Components & Diagram All Sizes Condenser Components 35 Diagrams AGZ A 36 Diagrams AGZ065A 37 Components Condenser Fan Deck and Condenser Motors 38 Components Sheet Metal & Hardware 39 Components Condenser Coils Cabinet 40 Components Panels, Control/Power Doors, Hardware 41 Components Panels, Control/Power Doors, Hardware 42 Diagram Coil Guards, Base Frame Guards, Hardware 43, 44 Components Coil Guards, Base Frame Guards, Hardware Piping Components 45 Diagrams Suction, Discharge and Liquid Lines 46 Components AGZ030, 035A 47 Components AGZ040, 045, 050A 48 Components AGZ055, 060, 065A 49 Evaporator 49 Diagrams & Components All Sizes 50 Vibration Isolators All Sizes 50 Flow Switch Field Installed Accessory 50 Alarm Belt Kit Field Installed Accessory CPL1-CPL2 Crtical Parts List Critical Parts List Air Cooled Scroll Chiller, AGZ Vint. A, Two-Circuit Rev. R 10/16 RPL / Page 2

3 Parts List Revision History Revision Date Description NEW 12/97 New A 7/01 Page 11 - Ref. #661A, Fuse, Fantrol Unit; AGZ /460V part number changed from to and AGZ /460V part number changed from to Page 20 - Added note to Alarm Light. Page 23 - Added Relay Base/Socket # Page 24 - Bub #931; Removed pn (Zone Terminal Display Only). Page 37 - AGZ /575V motor part number was changed from to Page 39 - Condenser Coils,AGZ , Std. Eff. (C03=S) Aluminum Fin Ref. # 7 & 8 part numbers are changed from to B 10/01 Page 26 & 33-Bub. #830 (.25" fitting) pn changed from to C 4/02 Page 26 - Sensor Ref #S01, S02, 'Connector only' part number changed from to Ref #750 Low Pressure Transducer part number changed from to D 6/02 Page 34 - Suction Gauge part number and Discharge Gauge number were reversed. The correct part numbers are- Suction Gauge ; Discharge Gauge E 10/02 Page 37- Bub #708; Fan Prop 28" part number was incorrect, the correct part number is F 11/02 Page 34 - Suction gauge (800lb) and Discharge gauge (150 lb) were switched. G 11/03 Page 47 -Added to list; Drier Shell, part number , quantity 2. H 11/03 Page 2- Index was missing references to pages 35-50, these were added back in. J 05/06 Pages 35 & 36 - Control Box diagram heading has word 'opposite' added. Added notes/info on discharge header connection, bubbles #6 & 7 were switched. Pages 39 - Added note-' The coil hand (left or right) is based on the discharge header connection point' and switched Ref #6 coil LH to coil RH and bub #7 coil RH to LH. K 12/08 Page Bub #690 add Disconnect Switch note. Page 34 - Ref No. 2 change Strap p/n from to Page 49 - Add Heater p/n to model #s E1004D1, E1204D2 and E1204D3. Add note to Cond. Tube. L 9/09 Page 37 - Ref #701 change motor - 575V p/n from N/A to M 11/09 Updated Cover and Revision pages with current logo design. Page 26- Changed quantity of Ref # 751, p/n from 1pc. to 2pc. Page 27- Changed duplicate Bub # 260 MHPR1 to MHRP2. Page 33- Deleted Ref # S10, N/S, Unit % Amp note. Page 49- In Component table deleted "Head Gaskets", "Cond Head" and "Cond. Tube" headings. Deleted "Connection Head" Reference from the drawing. N 06/11 Cover - Add "Two-Circuit" to title and document footer. Page 5 - Add Nomenclature Code 02 (unit sizes). Page 28 - Correct MT Controller part number to (was ). Page 39 - Correct Cond. Coil part numbers to xx series (were xx). Pages Correct description for Ref. L11 to "Filter Drier Core, High Capacity" and L12 to Filter Drier Core, Std, Capacity". P 10/13 Page 37- Rearranged page for clearer understanding of Fantrol and Speedtrol. Updated Motor part numbers. Page 49- Added part numbers for Evaporator Head Gaskets. Page 50- Removed Spring Isolator part numbers, added note to contact Daikin Applied. Pages 19, 20- Added CPL pages. Q 07/15 Page CPL1: Corrected part # for MicroTech Controller M250, was R 10/2016 Pages 45-48: Added D54 Hot Gas Bypass Solenoid Valve. Daikin Applied, Industrial Park Blvd., P.O. Box 1551, Minneapolis, MN (763) Air Cooled Scroll Chiller, AGZ Vint. A, Two-Circuit Rev. R 10/16 RPL / Page 3

4 Nomenclature Serial Number 5 6A Factory 5= Staunton,VA Engineering Revision Serial Number Year and Month of Manufacture: Year Month 6= 1996 A= Jan. 7= 1997 B= Feb. 8= 1998 C= Mar. 9= 1999 D= Apr. E= May F= Jun G= Jul H= Aug J= Sep. K= Oct. L= Nov. M= Dec. Unit Model Number AGZ 035 A S Application S= Standard Cooling E= High Efficiency Vintage Nominal Tonnage ex. 035= 35 Tons Unit Type: AGZ= Air- Cooled Global Scroll Compressor Chiller Stock Unit Model Number AGZ 035 A S 42 Voltage 42 = 208/230V 27 = 460V Application S= Standard Cooling E= High Efficiency Vintage Nominal Tonnage ex. 035 = 35 Tons Unit Type: AGZ= Air- Cooled Global Scroll Compressor Chiller Air Cooled Scroll Chiller, AGZ Vint. A, Two-Circuit Rev. R 10/16 RPL / Page 4

5 Unit Model Number- Complete Nomenclature Continued AGZ***A S 42 AL P C 04 2 A JYY D C R F S 11 1 B B E 1 EYA Code Unit Size (nominal tons) 030A = 30 tons, 2-ckt 035A = 35 tons, 2-ckt 040A = 40 tons, 2-ckt 045A = 45 tons, 2-ckt 050A = 50 tons, 2-ckt 055A = 55 tons, 2-ckt 060A = 60 tons, 2-ckt 065A = 65 tons, 2-ckt 03 Application S= Standard Cooling E= High Efficiency (030, 040, 050 only) 04 Voltage 42= 208/230/60/3 27= 460/60/3 37= 575/60/3 05 Starting Option AL= Across-The-Line 06 Power Connection P= Single Point Power Block D= Non-Fused Disconnect (Unit Mounted) 07 Compressor Short Circuit Protection Y= None C= Circuit Breakers 08 Capacity Control 04= 4 Steps Capacity Control 09 Hot Gas Bypass Y= None 2= HGBP Circuits 1 & 2 10 Control Circuit Transformer Y= None A= Control Circuit Transformer 11 Control Thermostat Options J** = UNT Johnson Controls J*D = UNT w/ Zone Terminal Display M** = MicroTech Controls 12 Phase Failure, Reversal and Ground Fault D= Phase Failure, Reversal with Under/Over Voltage and LED Lights V= Phase Failure, Reversal with Under/Over Voltage Y= Not Required 13 Miscellaneous Options Y= Not Required C= 115V Convenience Outlet G= Ground Fault Protection 14 Replaceable Core Filter Drier Y= None R= Replaceable Core Filter Driers 17 Protective Guard Y= Not Required A= Base Frame Guard around Entire Unit F= Vertical Condenser Coil Fin Guard and Option "A" G= Vertical Condenser Coil Fin Guard Only 18 Head Pressure Control F= FanTrol w/ Low Ambient T-Stat S= SpeedTrol w/ Low Ambient Start 19 Condenser Coil Fin Material 11= Aluminum 21= Copper 31= Aluminum w/ Baked Phenolic Coat 41= Copper w/ Baked Phenolic Coat 20 Condenser Fan Motors 1= Open Drip-Proof 2= Totally Enclosed (SpeedTrol Motors are ALWAYS ODP) 22 High Return Water/High Ambient Unload Y= Not Required R= High Water Return Unloader A= High Ambient Unloader B= Both R & A 23 Gauges Y= None B= Suction, Discharge Gauge- Ckts 1 & 2 24 & 25 Approval Listing and Packaging Options 26 Sensor Options UNT (example: EYA) E**= English Units M**= Metric Units *Y*= Modem (Not Available) **A= Outside Air Temp **E= Entering Water Temp. **U= Limited UNT Sensor Package MicroTech (example: EMR) E**= English Units M**= Metric Units *Y*= No Modem *M*= Modem **R= Standard Package **B= Refrigerant Temp. Package **D= % of Unit Amp. Draw Package **C= "R" + "B" + "D" Air Cooled Scroll Chiller, AGZ Vint. A, Two-Circuit Rev. R 10/16 RPL / Page 5

6 Tandem Compressors Compressor Arrangements Top View 1 3 Evap 2 4 Tandem Compressor Part Numbers 208/230/60/3 Unit Model No. Compressor 1 & Compressor 2 & Compressor 3 Compressor ZZ18M3-TWC-672 ZZ22M3-TWC ZZ22M3-TWC-672 ZZ22M3-TWC ZZ24M3-TWC-672 ZZ24M3-TWC ZZ24M3-TWC-672 ZZ32M3-TWC ZZ32M3-TWC-672 ZZ32M3-TWC ZZ32M3-TWC-672 ZZ38M3-TWC ZZ38M3-TWC-672 ZZ38M3-TWC ZZ38M3-TWC-672 ZZ38M3-TWC-672 Compressor Crankcase Heater: Air Cooled Scroll Chiller, AGZ Vint. A, Two-Circuit Rev. R 10/16 RPL / Page 6

7 Tandem Compressors Continued Tandem Compressor Part Numbers 460/60/3 Unit Model No. Compressor 1 & Compressor 2 & Compressor 3 Compressor ZZ18M3-TWD-672 ZZ22M3-TWD ZZ22M3-TWD-672 ZZ22M3-TWD ZZ24M3-TWD-672 ZZ24M3-TWD ZZ24M3-TWD-672 ZZ32M3-TWD ZZ32M3-TWD-672 ZZ32M3-TWD ZZ32M3-TWD-672 ZZ38M3-TWD ZZ38M3-TWD-672 ZZ38M3-TWD ZZ38M3-TWD-672 ZZ38M3-TWD-672 Crankcase Heater: Air Cooled Scroll Chiller, AGZ Vint. A, Two-Circuit Rev. R 10/16 RPL / Page 7

8 Tandem Compressors Continued Tandem Compressor Part Numbers 575/60/3 Unit Model No. Compressor 1 & Compressor 2 & Compressor 3 Compressor ZZ18M3-TWE-672 ZZ22M3-TWE ZZ22M3-TWE-672 ZZ22M3-TWE ZZ24M3-TWE-672 ZZ24M3-TWE ZZ24M3-TWE-672 ZZ32M3-TWE ZZ32M3-TWE-672 ZZ32M3-TWE ZZ32M3-TWE-672 ZZ38M3-TWE ZZ38M3-TWE-672 ZZ38M3-TWE ZZ38M3-TWE-672 ZZ38M3-TWE-672 Crankcase Heater: Air Cooled Scroll Chiller, AGZ Vint. A, Two-Circuit Rev. R 10/16 RPL / Page 8

9 Power Panel Panel Diagram 290 T1 674 FB A A PVM GRD PB 1 G F P 690 T10 FB6 FB7 CB1 CB3 CB2 CB4 DS plcs. M11 M12 M21 M22 M1 M3 M2 M4 CT RES1 SC Latches, Catches, Hinges plcs. Air Cooled Scroll Chiller, AGZ Vint. A, Two-Circuit Rev. R 10/16 RPL / Page 9

10 Power Panel AGZ 030, 035, 040, 045, 050, 055, 060, 065 Common Components Latches, Catches, Hinges, Ground Screw, Unit Amp Draw % Option, Ground Fault Relay & Sensor Ref. No. Schem. Sym. Description Part Number Qty. Latches, Catches, Hinges 132 Bracket- Magnet Door Catch Fastener- Magnet Catch Bracket Hinge Ground Screw 701 GRD Ground Screw Unit % Amps (C26= **D or **C) 980 CT Transformer- MicroTech Units (C11= M**) RES1 Resistor- MicroTech Units (C11= M**) SC Signal Converter- MicroTech Units (C11=M**) Signal Converter Spacer Ground Fault 990 GFP Ground Fault Protection Relay Ground Fault Relay Sensor Ground Fault Sensor Mount Ground Fault Relay Mount Air Cooled Scroll Chiller, AGZ Vint. A, Two-Circuit Rev. R 10/16 RPL / Page 10

11 Ref. No. Power Panel AGZ 030, 035, 040, 045, 050, 055, 060, 065 Common Components Schem. Sym. Speedtrol Transformer, Phase Voltage Monitor, Fan Contactors and Fuses, Control Transformer and Fuses Description Part Number 208/ 230V 460V 575V 290 T10 Transformer- Speedtrol (C18= S) PVM Phase Voltage Monitor (C12= D) PVM Phase Voltage Monitor (C12= D) PVM Phase Voltage Monitor (C12= D) PVM Phase Voltage Monitor (C12= V) PVM Phase Voltage Monitor (C12= V) A FB6 Fuse Block- Speedtrol Units (C18= S) FB6 Fuse Block- Fantrol Units (C18= F) FB7 Fuse Block A F6 Fuse- Speedtrol Units (C18= S) F6 Fuse- Speedtrol Units (C18= S) F6 Fuse- Fantrol Units (C18= F): AGZ F6 Fuse- Fantrol Units (C18= F): AGZ F6 Fuse- Fantrol Units (C18= F): AGZ F6 Fuse- Fantrol Units (C18= F): AGZ F6 Fuse- Fantrol Units (C18= F): AGZ F7 Fuse: AGZ F7 Fuse: AGZ F7 Fuse: AGZ F7 Fuse: AGZ F7 Fuse: AGZ F7 Fuse: AGZ M11,12,21,22 Fan Motor Contactor F5 Fuse- 5A F5 Fuse- 4.5A FB5 Fuse Block (C10= A) T1 Control Transformer (C10= A) T1 Control Transformer (C10= A) Air Cooled Scroll Chiller, AGZ Vint. A, Two-Circuit Rev. R 10/16 RPL / Page 11

12 Power Panel AGZ 030 Components Compressor Contactors, Compressor Circuit Breakers, Power Block, Disconnect Switches, Power Hubs Ref. No. Schem. Sym. Description Part Number 208/ 230V 460V 575V 533 M1, M3 Compressor Contactor- Compressors 1 & M2, M4 Compressor Contactor- Compressors 2 & CB1, CB3 Circuit Breaker- Compressors 1 & 3 (C07= C) CB1, CB3 Circuit Breaker- Compressors 1 & 3 (C07= C) CB1, CB3 Circuit Breaker- Compressors 1 & 3 (C07= C) CB2, CB4 Circuit Breaker- Compressors 2 & 4 (C07= C) CB2, CB4 Circuit Breaker- Compressors 2 & 4 (C07= C) CB2, CB4 Circuit Breaker- Compressors 2 & 4 (C07= C) PB1 Power Block (C06= P)- 335A PB1 Power Block (C06= P)- 175A DS1 Disconnect Switch- 225A DS1 Disconnect Switch- 100A N/S Power Hub- 1.25" N/S Power Hub- 1" Note: 1 The disconnect switch part number does not include the through-the-door mechanism (handle). The installed switch may be either a G. E. or a Cutler Hammer. The switches are interchangeable, but the associated handles are not. When replacing a handle, field verification of the switch's manufacturer is required to select the correct part number. The G. E. handle is p/n ; The Cutler Hammer handle is p/n The disconnect switch part number does not include the through-the-door mechanism (handle). The installed switch may be either a G. E. or a Cutler Hammer. The switches are interchangeable, but the associated handles are not. When replacing a handle, field verification of the switch's manufacturer is required to select the correct part number. The G. E. handle is p/n ; The Cutler Hammer handle is p/n Air Cooled Scroll Chiller, AGZ Vint. A, Two-Circuit Rev. R 10/16 RPL / Page 12

13 Power Panel AGZ 035 Components Compressor Contactors, Compressor Circuit Breakers, Power Block, Disconnect Switches, Power Hubs Ref. No. Schem. Sym. Description Part Number 208/ 230V 460V 575V 533 M1, M3 Compressor Contactor- Compressors 1 & M2, M4 Compressor Contactor- Compressors 2 & CB1, CB3 Circuit Breaker- Compressors 1 & 3 (C07= C) CB1, CB3 Circuit Breaker- Compressors 1 & 3 (C07= C) CB1, CB3 Circuit Breaker- Compressors 1 & 3 (C07= C) CB2, CB4 Circuit Breaker- Compressors 2 & 4 (C07= C) CB2, CB4 Circuit Breaker- Compressors 2 & 4 (C07= C) CB2, CB4 Circuit Breaker- Compressors 2 & 4 (C07= C) PB1 Power Block (C06= P)- 335A PB1 Power Block (C06= P)- 175A DS1 Disconnect Switch (C06= D)- 225A DS1 Disconnect Switch (C06= D)- 100A N/S Power Hub- 1.5" N/S Power Hub- 1" Note: 1 The disconnect switch part number does not include the through-the-door mechanism (handle). The installed switch may be either a G. E. or a Cutler Hammer. The switches are interchangeable, but the associated handles are not. When replacing a handle, field verification of the switch's manufacturer is required to select the correct part number. The G. E. handle is p/n ; The Cutler Hammer handle is p/n The disconnect switch part number does not include the through-the-door mechanism (handle). The installed switch may be either a G. E. or a Cutler Hammer. The switches are interchangeable, but the associated handles are not. When replacing a handle, field verification of the switch's manufacturer is required to select the correct part number. The G. E. handle is p/n ; The Cutler Hammer handle is p/n Air Cooled Scroll Chiller, AGZ Vint. A, Two-Circuit Rev. R 10/16 RPL / Page 13

14 Ref. No. Schem. Sym. Power Panel AGZ 040 Components Compressor Contactors, Compressor Circuit Breakers, Power Block, Disconnect Switches, Power Hubs Description Part Number 208/ 230V 460V 533 M1, M3 Compressor Contactor- Compressors 1 & M1, M3 Compressor Contactor- Compressors 1 & V 534 M2, M4 Compressor Contactor- Compressors 2 & M2, M4 Compressor Contactor- Compressors 2 & CB1, CB3 Circuit Breaker- Compressors 1 & 3 (C07= C) CB1, CB3 Circuit Breaker- Compressors 1 & 3 (C07= C) CB1, CB3 Circuit Breaker- Compressors 1 & 3 (C07= C) CB2, CB4 Circuit Breaker- Compressors 2 & 4 (C07= C) CB2, CB4 Circuit Breaker- Compressors 2 & 4 (C07= C) CB2, CB4 Circuit Breaker- Compressors 2 & 4 (C07= C) PB1 Power Block (C06= P)- 335A PB1 Power Block (C06= P)- 175A DS1 Disconnect Switch (C06= D)- 225A DS1 Disconnect Switch (C06= D)- 100A N/S Power Hub- 1.5" N/S Power Hub- 1.2" N/S Power Hub- 1.0" Note: 1 The disconnect switch part number does not include the through-the-door mechanism (handle). The installed switch may be either a G. E. or a Cutler Hammer. The switches are interchangeable, but the associated handles are not. When replacing a handle, field verification of the switch's manufacturer is required to select the correct part number. The G. E. handle is p/n ; The Cutler Hammer handle is p/n The disconnect switch part number does not include the through-the-door mechanism (handle). The installed switch may be either a G. E. or a Cutler Hammer. The switches are interchangeable, but the associated handles are not. When replacing a handle, field verification of the switch's manufacturer is required to select the correct part number. The G. E. handle is p/n ; The Cutler Hammer handle is p/n Air Cooled Scroll Chiller, AGZ Vint. A, Two-Circuit Rev. R 10/16 RPL / Page 14

15 Ref. No. Schem. Sym. Power Panel AGZ 045 Components Compressor Contactors, Compressor Circuit Breakers, Power Block, Disconnect Switches, Power Hubs Description Part Number 208/ 230V 460V 533 M1, M3 Compressor Contactor- Compressors 1 & M1, M3 Compressor Contactor- Compressors 1 & V 534 M2, M4 Compressor Contactor- Compressors 2 & M2, M4 Compressor Contactor- Compressors 2 & CB1, CB3 Circuit Breaker- Compressors 1 & 3 (C07= C) CB1, CB3 Circuit Breaker- Compressors 1 & 3 (C07= C) CB1, CB3 Circuit Breaker- Compressors 1 & 3 (C07= C) CB2, CB4 Circuit Breaker- Compressors 2 & 4 (C07= C) CB2, CB4 Circuit Breaker- Compressors 2 & 4 (C07= C) CB2, CB4 Circuit Breaker- Compressors 2 & 4 (C07= C) PB1 Power Block (C06= P)- 335A PB1 Power Block (C06= P)- 175A DS1 Disconnect Switch (C06= D)- 225A DS1 Disconnect Switch (C06= D)- 100A N/S Power Hub- 2.0" N/S Power Hub- 1.2" Note: 1 The disconnect switch part number does not include the through-the-door mechanism (handle). The installed switch may be either a G. E. or a Cutler Hammer. The switches are interchangeable, but the associated handles are not. When replacing a handle, field verification of the switch's manufacturer is required to select the correct part number. The G. E. handle is p/n ; The Cutler Hammer handle is p/n The disconnect switch part number does not include the through-the-door mechanism (handle). The installed switch may be either a G. E. or a Cutler Hammer. The switches are interchangeable, but the associated handles are not. When replacing a handle, field verification of the switch's manufacturer is required to select the correct part number. The G. E. handle is p/n ; The Cutler Hammer handle is p/n Air Cooled Scroll Chiller, AGZ Vint. A, Two-Circuit Rev. R 10/16 RPL / Page 15

16 Ref. No. Schem. Sym. Power Panel AGZ 050 Components Compressor Contactors, Compressor Circuit Breakers, Power Block, Disconnect Switches, Power Hubs Description Part Number 208/ 230V 460V 575V 533 M1, M3 Compressor Contactor- Compressors 1 & M1, M3 Compressor Contactor- Compressors 1 & M2, M4 Compressor Contactor- Compressors 2 & M2, M4 Compressor Contactor- Compressors 2 & CB1, CB3 Circuit Breaker- Compressors 1 & 3 (C07= C) CB1, CB3 Circuit Breaker- Compressors 1 & 3 (C07= C) CB1, CB3 Circuit Breaker- Compressors 1 & 3 (C07= C) CB2, CB4 Circuit Breaker- Compressors 2 & 4 (C07= C) CB2, CB4 Circuit Breaker- Compressors 2 & 4 (C07= C) CB2, CB4 Circuit Breaker- Compressors 2 & 4 (C07= C) PB1 Power Block (C06= P)- 335A PB1 Power Block (C06= P)- 175A DS1 Disconnect Switch (C06= D)- 225A DS1 Disconnect Switch (C06= D)- 150A N/S Power Hub- 2.0" N/S Power Hub- 1.2" Note: 1 The disconnect switch part number does not include the through-the-door mechanism (handle). The installed switch may be either a G. E. or a Cutler Hammer. The switches are interchangeable, but the associated handles are not. When replacing a handle, field verification of the switch's manufacturer is required to select the correct part number. The G. E. handle is p/n ; The Cutler Hammer handle is p/n The disconnect switch part number does not include the through-the-door mechanism (handle). The installed switch may be either a G. E. or a Cutler Hammer. The switches are interchangeable, but the associated handles are not. When replacing a handle, field verification of the switch's manufacturer is required to select the correct part number. The G. E. handle is p/n ; The Cutler Hammer handle is p/n Air Cooled Scroll Chiller, AGZ Vint. A, Two-Circuit Rev. R 10/16 RPL / Page 16

17 Ref. No. Schem. Sym. Power Panel AGZ 055 Components Compressor Contactors, Compressor Circuit Breakers, Power Block, Disconnect Switches, Power Hubs Description Part Number 208/ 230V 460V 533 M1, M3 Compressor Contactor- Compressors 1 & M1, M3 Compressor Contactor- Compressors 1 & V 534 M2, M4 Compressor Contactor- Compressors 2 & M2, M4 Compressor Contactor- Compressors 2 & CB1, CB3 Circuit Breaker- Compressors 1 & 3 (C07= C) CB1, CB3 Circuit Breaker- Compressors 1 & 3 (C07= C) CB1, CB3 Circuit Breaker- Compressors 1 & 3 (C07= C) CB2, CB4 Circuit Breaker- Compressors 2 & 4 (C07= C) CB2, CB4 Circuit Breaker- Compressors 2 & 4 (C07= C) CB2, CB4 Circuit Breaker- Compressors 2 & 4 (C07= C) PB1 Power Block (C06= P)- 335A PB1 Power Block (C06= P)- 175A DS1 Disconnect Switch (C06= D)- 400A DS1 Disconnect Switch (C06= D)- 150A N/S Power Hub- 2.0" N/S Power Hub- 1.2" Note: 1 The disconnect switch part number does not include the through-the-door mechanism (handle). The installed switch may be either a G. E. or a Cutler Hammer. The switches are interchangeable, but the associated handles are not. When replacing a handle, field verification of the switch's manufacturer is required to select the correct part number. The G. E. handle is p/n ; The Cutler Hammer handle is p/n The disconnect switch part number does not include the through-the-door mechanism (handle). The installed switch may be either a G. E. or a Cutler Hammer. The switches are interchangeable, but the associated handles are not. When replacing a handle, field verification of the switch's manufacturer is required to select the correct part number. The G. E. handle is p/n ; The Cutler Hammer handle is p/n Air Cooled Scroll Chiller, AGZ Vint. A, Two-Circuit Rev. R 10/16 RPL / Page 17

18 Ref. No. Schem. Sym. Power Panel AGZ 060 Components Compressor Contactors, Compressor Circuit Breakers, Power Block, Disconnect Switches, Power Hubs Description Part Number 208/ 230V 460V 533 M1, M3 Compressor Contactor- Compressors 1 & M1, M3 Compressor Contactor- Compressors 1 & V 534 M2, M4 Compressor Contactor- Compressors 2 & M2, M4 Compressor Contactor- Compressors 2 & CB1, CB3 Circuit Breaker- Compressors 1 & 3 (C07= C) CB1, CB3 Circuit Breaker- Compressors 1 & 3 (C07= C) CB1, CB3 Circuit Breaker- Compressors 1 & 3 (C07= C) CB2, CB4 Circuit Breaker- Compressors 2 & 4 (C07= C) CB2, CB4 Circuit Breaker- Compressors 2 & 4 (C07= C) CB2, CB4 Circuit Breaker- Compressors 2 & 4 (C07= C) PB1 Power Block (C06= P)- 335A PB1 Power Block (C06= P)- 175A DS1 Disconnect Switch (C06= D)- 400A DS1 Disconnect Switch (C06= D)- 150A N/S Power Hub- 2.5" N/S Power Hub- 1.2" Note: 1 The disconnect switch part number does not include the through-the-door mechanism (handle). The installed switch may be either a G. E. or a Cutler Hammer. The switches are interchangeable, but the associated handles are not. When replacing a handle, field verification of the switch's manufacturer is required to select the correct part number. The G. E. handle is p/n ; The Cutler Hammer handle is p/n The disconnect switch part number does not include the through-the-door mechanism (handle). The installed switch may be either a G. E. or a Cutler Hammer. The switches are interchangeable, but the associated handles are not. When replacing a handle, field verification of the switch's manufacturer is required to select the correct part number. The G. E. handle is p/n ; The Cutler Hammer handle is p/n Air Cooled Scroll Chiller, AGZ Vint. A, Two-Circuit Rev. R 10/16 RPL / Page 18

19 Ref. No. Schem. Sym. Power Panel AGZ 065 Components Compressor Contactors, Compressor Circuit Breakers, Power Block, Disconnect Switches, Power Hubs Description Part Number 208/ 230V 460V 533 M1, M3 Compressor Contactor- Compressors 1 & M1, M3 Compressor Contactor- Compressors 1 & V 534 M2, M4 Compressor Contactor- Compressors 2 & M2, M4 Compressor Contactor- Compressors 2 & CB1, CB3 Circuit Breaker- Compressors 1 & 3 (C07= C) CB1, CB3 Circuit Breaker- Compressors 1 & 3 (C07= C) CB1, CB3 Circuit Breaker- Compressors 1 & 3 (C07= C) CB2, CB4 Circuit Breaker- Compressors 2 & 4 (C07= C) CB2, CB4 Circuit Breaker- Compressors 2 & 4 (C07= C) CB2, CB4 Circuit Breaker- Compressors 2 & 4 (C07= C) PB1 Power Block (C06= P)- 335A Power Block (C06= P)- 175A DS1 Disconnect Switch (C06= D)- 400A Disconnect Switch (C06= D)- 150A N/S Power Hub- 2.5" N/S Power Hub- 1.2" Note: 1 The disconnect switch part number does not include the through-the-door mechanism (handle). The installed switch may be either a G. E. or a Cutler Hammer. The switches are interchangeable, but the associated handles are not. When replacing a handle, field verification of the switch's manufacturer is required to select the correct part number. The G. E. handle is p/n ; The Cutler Hammer handle is p/n The disconnect switch part number does not include the through-the-door mechanism (handle). The installed switch may be either a G. E. or a Cutler Hammer. The switches are interchangeable, but the associated handles are not. When replacing a handle, field verification of the switch's manufacturer is required to select the correct part number. The G. E. handle is p/n ; The Cutler Hammer handle is p/n Air Cooled Scroll Chiller, AGZ Vint. A, Two-Circuit Rev. R 10/16 RPL / Page 19

20 Control Panel Components UNT Control Panel Diagram- Left Side (Code 11= JYY, JZY, JRY, JDY, JYD, JZD, JRD, or JDD) System Circuit Circuit Setpoint Control Band Switch No. 1 No. 2 Auto Auto Auto Alarm S1 PS1 100 PS2 Status 102 Emergency Stop Freezestat Reset Pumpdown and Stop 101 Note: The Alarm Light is a field replaceable part. Pumpdown and Stop Switch Plate T2 RPS MPR1 MPR2 CRR1 CRR2 126 Wireway 128 TC 11 F1 F2 UNT CB R 9 R 10 R 21 R 22 TB Wireway TB 7 TB 2 TB Ground Bus Air Cooled Scroll Chiller, AGZ Vint. A, Two-Circuit Rev. R 10/16 RPL / Page 20

21 Control Panel Components UNT Control Panel Components- Left Side (Code 11= JYY, JZY, JRY, JDY, JYD, JZD, JRD, or JDD) Ref# Schematic Description Part Number Qty. Symbol 100 S1, PS1, PS2 Switch Freezestat Reset Button Potentiometer: Setpoint and Control Band UNT Main Controller- Johnson Controls Central Processor T2 Control Circuit Transformer- 120V- 24V RPS-1 Reg. Power Supply: 120VA- 5VDC MPR1,2 CRR1,2 Relay CB1 Circuit Breaker F1 Fuse- 15A F2 Fuse- 10A Ground Bus R9, R10 Relay- Hot Gas Bypass R21, R22 Relay- Hi Ambient Unloading TC11 Temperature Control- HiWater Unloading w/bulb Air Cooled Scroll Chiller, AGZ Vint. A, Two-Circuit Rev. R 10/16 RPL / Page 21

22 Control Panel Components UNT Control Panel Diagram- Right Side (Code 11= JYY, JZY, JRY, JDY, JYD, JZD, JRD, or JDD) Wireway Wireway B08 B07 B04 B03 B02 B TB 6 TB 7 Wireway Neutral Bus 156 Wireway MPH-1 MPH-2 PC 12 PC Air Cooled Scroll Chiller, AGZ Vint. A, Two-Circuit Rev. R 10/16 RPL / Page 22

23 Control Panel Components UNT Control Panel Components- Right Side (Code 11= JYY, JZY, JRY, JDY, JYD, JZD, JRD, or JDD) Ref# Schematic Description Part Number Qty. Symbol 150 MPH-1, 2 Mechanical Pressure Switch Neutral Bus B01- B08 Output Relays N/S Relay Base/Socket (for B01-B08 Output Relays) PC12, PC22 Pressure Control- FanTrol Head Pressure Air Cooled Scroll Chiller, AGZ Vint. A, Two-Circuit Rev. R 10/16 RPL / Page 23

24 Control Panel Components UNT Zone Terminal Display (Code 11= J*D) Ref# Description Part Number Qty. 128 Channel w/o Convenience Outlet (C13= Y) Channel with Convenience Outlet (C13= C) Mounting Bracket- Zone Terminal Zone Terminal Kit (kit includes- Zone Terminal, Cable and Bracket) Zone Terminal Cable Terminal Bracket Air Cooled Scroll Chiller, AGZ Vint. A, Two-Circuit Rev. R 10/16 RPL / Page 24

25 Control Panel Components UNT Control Panel Components Unit Mounted Sensors & Controls, Solenoid Valve Junction Box (Code 11= JYY, JZY, JRY, JDY, JYD, JZD, JRD, or JDD) Diagrams Top View 841 Detail 2 (Back of Control Box) 841 S09 LP1 (circuit 1) S01 See Detail 1 S09 See Detail 2 OAT LP2 (circuit 2) S08 See Detail 3 EWT (optional) S02 See Detail 1 Detail 1 S01 or 750 S02 S00 See Detail 3 LWT (standard) Detail 3 Evaporator Water Temperature Sensor Shrader fitting on compressor SV1 SV2 793 From Control Box Junction Box- SV1, SV2, Evap. Heater 791 S08 or S PC22- see control panel for PN PC12- see control panel for PN 751 High Pressure Staging Control 840 View from back of control box Air Cooled Scroll Chiller, AGZ Vint. A, Two-Circuit Rev. R 10/16 RPL / Page 25

26 Control Panel Components UNT Control Panel Unit Mounted Sensors & Controls, Solenoid Valve Junction Box (Code 11= JYY, JZY, JRY, JDY, JYD, JZD, JRD, or JDD) Components Controls and Hardware Ref# Description Part Number Qty. 751 Hi-Pressure Fan Staging Control N/S Pressure Control- Hi Ambient Unloading Junction Box Junction Box Cover Conduit Fitting- 1/2" Conduit Fitting- 3/8" Fitting-.25" Well- Evap Nozzle Bulb Paste N/A 840 Bushing Outside Air Sensor Clamp Sensors Ref# Description Part Number Qty. S01, S02 L.P. Compressor Sensor Cable Assembly Includes wires, boot, terminals, connector Connector only Transducer Boot Low Pressure Transducer S08 or S00 Leaving or Entering Water Temperature Sensor S09 Outdoor Air Temperature Sensor Air Cooled Scroll Chiller, AGZ Vint. A, Two-Circuit Rev. R 10/16 RPL / Page 26

27 Control Panel Components MicroTech Control Panel Diagram- Left Side (Code 11= MAY, MCY, MDY, MYY) 260 MHPR 1 MPR 1 MPR 3 MHPR 2 MPR 2 MPR 4 Wireway TB M250 10BT ADI T4 F1 CB F T2 NB TB Wireway 231 TB2 NB 243 TB3 231 Air Cooled Scroll Chiller, AGZ Vint. A, Two-Circuit Rev. R 10/16 RPL / Page 27

28 Control Panel Components MicroTech Control Panel Components- Left Side (Code 11= MAY, MCY, MDY, MYY) Ref# Schematic Description Part Number Qty. Symbol 179 Bracket for F1, F2, CB F1 Fuse- 15A Fuse Holder for F1, F F2 Fuse- 10A T2 Transformer: 120V- 24V T4 Transformer: 24V- 18V TB2, TB3, TB4, TB7 Terminal Block- 16 Terminals NB Neutral Block- 7 Pole NB Neutral Block- NE16P MHPR1,2, MPR1,2,3,4 Relay- 1PDT, 30A M250 MicroTech Controller M250 (must be programmed) M250 Mounting Channel ADI ADI Board Ribbon Cable N/S Varistor Ass'y- 30V Varistor Only CB Circuit Breaker Modem Kit (w/cord set) (C26= *M*) Modem Only Cord Set Only Modem Interface Cable Gasket Modem Bracket Modem Bracket- Vertical N/S Alarm Bell (Mounted on Outside of Control Box) Air Cooled Scroll Chiller, AGZ Vint. A, Two-Circuit Rev. R 10/16 RPL / Page 28

29 Control Panel Components MicroTech Control Panel Diagram- Right Side (Code 11= MAY, MCY, MDY, MYY) j;cxvj jdskgj j;cxvj jdskgj j;cxvj jdskgj j;cxvj jdskgj j;cxvj jdskgj 251 j;cxvj jdskgj j;cxvj jdskgj j;cxvj jdskgj j;cxvj jdskgj j;cxvj jdskgj TB8 j;cxvj jdskgj j;cxvj jdskgj j;cxvj jdskgj j;cxvj jdskgj j;cxvj jdskgj j;cxvj jdskgj j;cxvj jdskgj TB Wireway TB6 231 Air Cooled Scroll Chiller, AGZ Vint. A, Two-Circuit Rev. R 10/16 RPL / Page 29

30 Control Panel Components MicroTech Control Panel Components- Right Side (Code 11= MAY, MCY, MDY, MYY) Ref# Schematic Description Part Number Qty. Symbol 231 TB5, TB6 Terminal Block- 16 Terminals TB8 Terminal Block- 9 Terminals Output Board Output Board Relays- Units with HGBP (C09 =2) Output Board Relays- Units w/o HGBP (C09 =Y) Ribbon Cable Air Cooled Scroll Chiller, AGZ Vint. A, Two-Circuit Rev. R 10/16 RPL / Page 30

31 Control Panel Components MicroTech Control Panel Keypad Display (Code 11= MAY, MCY, MDY, MYY) SYSTEM SWITCH CIRCUIT NO. 1 CIRCUIT NO. 2 ALARM STOP PUMPDOWN AND STOP ~ PUMPDOWN AND STOP Part Ref. No. Description Number Qty. 955 Keypad Label Keypad Display Switch- 125V Red LED Lamp N/S Mounting Channel with Outlet (C13=C) N/S Mounting Channel w/o Outlet (C13=Y) Air Cooled Scroll Chiller, AGZ Vint. A, Two-Circuit Rev. R 10/16 RPL / Page 31

32 Control Panel Components MicroTech Control Panel Components Unit Mounted Sensors & Controls, Solenoid Valve Junction Box (Code 11= MAY, MCY, MDY, MYY) Diagrams Top View See Detail 4 S13 S15 S12 S14 S03 See Detail 1 S01 See Detail 1 S09 See Detail 2 S08 See Detail 3 S04 See Detail 1 S02 See Detail 1 S00 See Detail 3 Detail 1 S03 or S04 S01 or S or 749 Detail 4 S14 Detail 2 (Back of Control Box) S12 S Shrader fitting on compressor S13 Detail 3 Evaporator Water Temperature Sensor S or 831 S S09 Junction Box- SV1, SV2, Evap. Heater SV1 793 SV2 793 View from back of control box From Control Box Air Cooled Scroll Chiller, AGZ Vint. A, Two-Circuit Rev. R 10/16 RPL / Page 32

33 Control Panel Components MicroTech Control Panel Unit Mounted Sensors & Controls, Solenoid Valve Junction Box Controls and Hardware (Code 11= MAY, MCY, MDY, MYY) Components Ref# Description Part Number Qty. 563 Sensor Tube- Suction and Liquid Tube Sensors Junction Box Junction Box Cover Conduit Fitting- 1/2" Conduit Fitting- 3/8" Fitting-.25" Well- Evap Nozzle Bulb Paste N/A 840 Bushing Outside Air Sensor Clamp Sensors Ref# Description Part Number Qty. S00 Evap. Leaving Water Temp. 30' Lead S01 (750) Low Pressure Transducer: Circuit # S02 (750) Low Pressure Transducer: Circuit # S03 (749) High Pressure Transducer: Circuit # S04 (749) High Pressure Transducer: Circuit # S08 Evap. Entering Water Temp. 10' Lead S09 Outside Air Temp. 10' Lead S12 Suction Line Temp. Circuit #1 10' Lead S13 Suction Line Temp. Circuit #2 10' Lead S14 Liquid Line Temp. Circuit #1 10' Lead S15 Liquid Line Temp. Circuit #2 10' Lead Cables Cable Cable Cable Sensors Type Part Number Terminus Included J , 2 None POWER , 5 None COM , 5 None ADI- AH , 2 S00, 01, 02, 03 ADI- AH , 2 S04 ADI- AH (Code 26= **R or **B) 1, 2 S08, S09 ADI- AH (Code 26= **D or **C) 1, 2 S08, S09, S10 ADI- AH (Code 26= **B or **C) 1, 2 S12, S13, S14, S15 ADI- DH , 2 None ADI- DH , 2 None Terminus Key: 1= 9 pole Terminal block pn: ; 2= Terminal block cover pn: ; 3= Terminal Hsg, Female 4-Pin pn: ; 4= Terminal Hsg. Female 6-Pin pn: ; 5= Terminal Pin (qty. 3) pn: Air Cooled Scroll Chiller, AGZ Vint. A, Two-Circuit Rev. R 10/16 RPL / Page 33

34 Control Panel Components Speedtrol Components (C18= S) UNT or MicroTech Controls Part Ref. No. Description Number Qty. 1 P66 Speedtrol Control * 2 Strap- Capacitor * 3 Capacitor- 30MFD, 440V * 806 Speedtrol Box- Circuit One Speedtrol Box- Circuit Two Transformer- 575V Only (C04= 37) Bracket- 575V Only (C04= 37) Angle- Speedtrol Boxes Bottom Support Bracket N/S Weather Cover- Speedtrol Boxes *Included in Speedtrol Boxes (806 & 807). Quantity is one per box. Convenience Outlet (C13= C) and Gauges (C23= B) UNT or MicroTech Controls Part Ref. No. Description Number Qty. N/S Convenience Outlet Receptacle N/S Convenience Outlet Fuse- 10A N/S Convenience Outlet Fuse Holder- 15A N/S Suction Gauge- 800# N/S Discharge Gauge- 150# N/S Gauge Shutoff Valve Air Cooled Scroll Chiller, AGZ Vint. A, Two-Circuit Rev. R 10/16 RPL / Page 34

35 Condenser Section AGZ030, 035, 040, 045, 050, 055, 060A Fan and Motor Cross Section- Typical See Detail One Detail One B50 B84 B93 B03 Fan Deck 679 B50 Motor Mount B B83 B Coil Blockoff Panels Side View- L.H. Shown Coils End View- Opposite Control Box End Circuit #2 * 7 * * Circuit #1 * * Discharge header connection. NOTE- The coil hand (left or right) is based on the discharge header connection point. Air Cooled Scroll Chiller, AGZ Vint. A, Two-Circuit Rev. R 10/16 RPL / Page 35

36 Condenser Section AGZ065A Fan and Motor Cross Section- Typical See Detail One B84 B03 Detail One 679 B50 B93 Fan Deck 679 B50 Motor Mount B B83 B Coil Blockoff Panels Side View- L.H. Shown Coils End View- Opposite Control Box End * Circuit # * 690 * Circuit #1 * 726 C.B. end opp. C.B. end * Discharge header connection. NOTE- The coil hand (left or right) is based on the discharge header connection point. Air Cooled Scroll Chiller, AGZ Vint. A, Two-Circuit Rev. R 10/16 RPL / Page 36

37 Condenser Section Components- Condenser Fan Deck Condenser Fan Components Ref# Qty. Description Part Number Fan Deck Panel Venturi Plate Venturi Angle Rain Slinger Fan Grille 32" Condenser Fan Motor Mounts and Fan Props Ref# Qty. Description Part Number Motor Mount for 1.5HP Motor (2 per motor) Motor Mount for 1.0 HP Std or Speedtrol Motors (2 per motor) Fan Prop, 28", for 1.5 HP Motors Fan Prop, 28", for 1.0 HP Std or Speedtrol Motors Speedtrol units (C18= S) use 2 Speedtrol Motors & 2 Standard Motors. Fantrol units (C18= F) use 4 Standard Motors. Motors- AGZ A Ref# Qty. Description Part Number Standard Motor (C20= 1) 208/230/460V, 1.0 HP V, 1.5 HP Speedtrol 1.0 HP Motor All Voltages Speedtrol units (C18= S) use 2 Speedtrol Motors & 2 Standard Motors. Fantrol units (C18= F) use 4 Standard Motors. Motors- AGZ A Ref# Qty. Description Part Number Standard Motor (C20= 1) 208/230/460V, 1.5 HP V, 1.5 HP Totally- Enclosed 1.5 HP Motor (C20= 2) 208/230/460V, 1.5 HP V, 2.0 HP Speedtrol 1.0 HP Motor All Voltages Speedtrol units (C18= S) use 2 Speedtrol Motors & 2 Standard Motors. Fantrol units (C18= F) use 4 Standard Motors. Air Cooled Scroll Chiller, AGZ Vint. A, Two-Circuit Rev. R 10/16 RPL / Page 37

38 Condenser Section Components- Sheet Metal and Hardware Sheet Metal- AGZ A Ref# Qty. Description Part Number Rear Blockoff Panel- R.H. Coil Rear Blockoff Panel- L.H. Coil Front Blockoff Panel- R.H. Coil Front Blockoff Panel- R.H. Coil Middle Blockoff Panel- R. H. Coil Middle Blockoff Panel- L. H. Coil Top Coil Support- R.H. Coil Top Coil Support- L.H. Coil Cable Trough- R.H. Coil Cable Trough- L.H. Coil Side Rail- R.H. Coil Side Rail- L.H. Coil Cross Brace Cross Brace Sheet Metal- AGZ065A Ref# Qty. Description Part Number Rear Blockoff Panel- R.H. Coil Rear Blockoff Panel- L.H. Coil Front Blockoff Panel- R.H. Coil Front Blockoff Panel- R.H. Coil Middle Blockoff Panel- R. H. Coil Middle Blockoff Panel- L. H. Coil Cable Trough- R.H. Coil Cable Trough- L.H. Coil Side Rail- R.H. Coil Side Rail- L.H. Coil Cross Brace Cross Brace Coil Support Bracket- C.B. End Coil Support Bracket-Opp. C.B. End Angle/Coil Support Hardware- All Unit Sizes Ref# Qty. Description Part Number B03 * Screw B14 16 Screw B50 16 Flat Washer B83 16 Lock Nut B84 16 Lock Nut B93 48 Washer *varies Air Cooled Scroll Chiller, AGZ Vint. A, Two-Circuit Rev. R 10/16 RPL / Page 38

39 Condenser Section Components- Coils Condenser Coils AGZ030, 035, 040, 045, 050A Standard Efficiency Units (C03= S) Aluminum Fin (C19= 11) Ref# Description Part No. 6 Coil- RH Coil- LH Coil- LH Coil- RH Condenser Coils AGZ030, 040, 050A High Efficiency Units (C03= E) Aluminum Fin (C19= 11) Ref# Description Part No. 6 Coil- RH Coil- LH Coil- LH Coil- RH Condenser Coils AGZ055, 060A Standard Efficiency Units (C03= S) Aluminum Fin (C19= 11) Ref# Description Part No. 6 Coil- RH Coil- LH Coil- LH Coil- RH Condenser Coils AGZ065A Standard Efficiency Units (C03= S) Aluminum Fin (C19= 11) Ref# Description Part No. 6 Coil- RH Coil- LH Coil- LH Coil- RH Condenser Coils AGZ030, 035, 040, 045, 050A Standard Efficiency Units (C03= S) Copper Fin (C19= 21) Ref# Description Part No. 6 Coil- RH Coil- LH Coil- LH Coil- RH Condenser Coils AGZ030, 040, 050A High Efficiency Units (C03= E) Copper Fin (C19= 21) Ref# Description Part No. 6 Coil- RH Coil- LH Coil- LH Coil- RH Condenser Coils AGZ055, 060A Standard Efficiency Units (C03= S) Copper Fin (C19= 21) Ref# Description Part No. 6 Coil- RH Coil- LH Coil- LH Coil- RH Condenser Coils AGZ065A Standard Efficiency Units (C03= S) Copper Fin (C19= 21) Ref# Description Part No. 6 Coil- RH Coil- LH Coil- LH Coil- RH NOTE- The coil hand (left or right) is based on the discharge header connection point. Air Cooled Scroll Chiller, AGZ Vint. A, Two-Circuit Rev. R 10/16 RPL / Page 39

40 Cabinet Panels, Control/Power Doors, Hardware Diagrams 870 B B B04 B03 B03 B04 B91 B B ~ B B03 58 both sides 880 Air Cooled Scroll Chiller, AGZ Vint. A, Two-Circuit Rev. R 10/16 RPL / Page 40

41 Cabinet Panels, Control/Power Doors, Hardware Components Ref. No. Description Part Number Qty. B01 Screw B03 Screw B04 Screw B91 Gasket ft. 42 Front Corner Post- Right Hand Front Corner Post- Left Hand Rear Corner Post- L.H. & R.H Corner Panel, Back- L.H. AGZ A Corner Panel, Back- L.H. AGZ065A Corner Panel, Back- R.H. AGZ A Corner Panel, Back- R.H. AGZ065A Corner Panel, Front- L.H. AGZ A Corner Panel, Front- L.H. AGZ065A Top Panel, Rear AGZ065A only Louvered Back Panel AGZ A Louvered Back Panel AGZ065A R.H. Power Panel Door Top Panel, Front AGZ065A only Front Panel AGZ A Front Panel AGZ065A L.H. Power Panel Door Dead Door Reinforcement Control Panel Dead Door Control Panel Door Corner Panel, Front- R.H. AGZ A Corner Panel, Front- R.H. AGZ065A Hinge- 2" Fastener- Door Lock w/key Air Cooled Scroll Chiller, AGZ Vint. A, Two-Circuit Rev. R 10/16 RPL / Page 41

McQuay. Air-Cooled Global Reciprocating Condensing Unit. ACR Vintage A. Last Manufactured: 2003

McQuay. Air-Cooled Global Reciprocating Condensing Unit. ACR Vintage A. Last Manufactured: 2003 Replacement Parts List No. 110504800 Revision G 04/2016 McQuay Air-Cooled Global Reciprocating Condensing Unit ACR 060-120 Vintage A Last Manufactured: 2003 To find your Daikin Applied parts distributor,

More information

McQuay Air-Cooled Reciprocating Chiller ALR

McQuay Air-Cooled Reciprocating Chiller ALR Replacement Parts List No. 057115200 Revision S 07/2015 McQuay Air-Cooled Reciprocating Chiller ALR Sizes 010-185 Vintage D Last Manufactured: 2000 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Evaporative Condenser Cooled Chiller. EGR Vintage A. Last Manufactured: Replacement Parts List No Revision B 07/2010

McQuay. Evaporative Condenser Cooled Chiller. EGR Vintage A. Last Manufactured: Replacement Parts List No Revision B 07/2010 Replacement Parts List No. 700015100 Revision B 07/2010 McQuay Evaporative Condenser Cooled Chiller EGR 060-240 Vintage A Last Manufactured: 2004 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Reciprocating Condensing Unit. ALP Vintage C. Last Manufactured: Replacement Parts List No Revision W 10/2017

McQuay. Reciprocating Condensing Unit. ALP Vintage C. Last Manufactured: Replacement Parts List No Revision W 10/2017 Replacement Parts List No. 700015000 Revision W 10/2017 McQuay Reciprocating Condensing Unit ALP 013-230 Vintage C Last Manufactured: 2002 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Water-Cooled Screw Chiller. PFS Vintage B. Last Manufactured: Replacement Parts List No Revision D 02/2017

McQuay. Water-Cooled Screw Chiller. PFS Vintage B. Last Manufactured: Replacement Parts List No Revision D 02/2017 Replacement Parts List No. 057118200 Revision D 02/2017 McQuay Water-Cooled Screw Chiller PFS 150-215 Vintage B Last Manufactured: 1997 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. Incremental. Suite II, 2 Motor PDES Design C (3) Last Manufactured: 2008

Daikin McQuay. Incremental. Suite II, 2 Motor PDES Design C (3) Last Manufactured: 2008 Replacement Parts List 700018500 Revision B 02/2012 Daikin McQuay Incremental Suite II, 2 Motor PDES 009-015 Design C (3) Last Manufactured: 2008 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Air Cooled Screw Chiller. ALS Vintage B. Last Manufactured: Replacement Parts List No Revision B 05/2016

McQuay. Air Cooled Screw Chiller. ALS Vintage B. Last Manufactured: Replacement Parts List No Revision B 05/2016 Replacement Parts List No. 700027200 Revision B 05/2016 cquay Air Cooled Screw Chiller ALS 220-280 Vintage B Last anufactured: 2001 To find your Daikin Applied parts distributor, call 1-800-377-2787 or

More information

McQuay. Water Source Heat Pump. HPH, HPV Vintage A, B. Last Manufactured: Replacement Parts List No Revision B 05/2012

McQuay. Water Source Heat Pump. HPH, HPV Vintage A, B. Last Manufactured: Replacement Parts List No Revision B 05/2012 Replacement Parts List No. 055211500 Revision B 05/2012 McQuay Water Source Heat Pump HPH, HPV 009-059 Vintage A, B Last Manufactured: 1986 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. EnerSaver Packaged Terminal Air Conditioner/Heat Pump. PNES; PNHS Design C (3)

Daikin McQuay. EnerSaver Packaged Terminal Air Conditioner/Heat Pump. PNES; PNHS Design C (3) Replacement Parts List No. 700018700 Revision E 04/2015 Daikin McQuay EnerSaver Packaged Terminal Air Conditioner/Heat Pump PNES; PNHS 009-015 Design C (3) To find your Daikin Applied parts distributor,

More information

McQuay. Air Cooled Screw Chiller. ALS Vintage B. Last Manufactured: Replacement Parts List No Revision C 06/2017

McQuay. Air Cooled Screw Chiller. ALS Vintage B. Last Manufactured: Replacement Parts List No Revision C 06/2017 Replacement Parts List No. 700027300 Revision C 06/2017 cquay Air Cooled Screw Chiller ALS 300-425 Vintage B Last anufactured: 2001 To find your Daikin Applied parts distributor, call 1-800-377-2787 or

More information

McQuay. Seasonmaker Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage A. Last Manufactured: 1986

McQuay. Seasonmaker Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage A. Last Manufactured: 1986 Replacement Parts List No. 47650300 Rev. A 09/205 McQuay Seasonmaker Large Capacity Fan Coil Direct Drive SCD, SHD 06-20 Vintage A Last Manufactured: 986 To find your Daikin Applied parts distributor,

More information

McQuay. Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage B. FSCD, FSHD Design A (1)

McQuay. Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage B. FSCD, FSHD Design A (1) Replacement Parts List No. 055236500 Revision J 07/207 McQuay Large Capacity Fan Coil Direct Drive SCD, SHD 06-20 Vintage B FSCD, FSHD 06-20 Design A () To find your Daikin Applied parts distributor, call

More information

McQuay. Incremental. PFEC, PFES, PFHC, PFHS Suite II, 2 Motor 007, 009, 012, 015 Designs A(1), B(2) Last Manufactured: 2001

McQuay. Incremental. PFEC, PFES, PFHC, PFHS Suite II, 2 Motor 007, 009, 012, 015 Designs A(1), B(2) Last Manufactured: 2001 Replacement Parts List 110505300 Revision G 07/2016 McQuay Incremental PFEC, PFES, PFHC, PFHS Suite II, 2 Motor 007, 009, 012, 015 Designs A(1), B(2) Last Manufactured: 2001 To find your Daikin Applied

More information

McQuay. Seasonmaker Fan Coil. TSF, TSB, TSC Vintage C. Last Manufactured: Replacement Parts List No Revision D 09/2016

McQuay. Seasonmaker Fan Coil. TSF, TSB, TSC Vintage C. Last Manufactured: Replacement Parts List No Revision D 09/2016 Replacement Parts List No. 055211000 Revision D 09/2016 McQuay Seasonmaker Fan Coil TSF, TSB, TSC 021-151 Vintage C Last Manufactured: 1989 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. Air- Cooled Condenser. ACH, ACX, ACL Vintage A. Replacement Parts List No Revision C 10/2016

Daikin McQuay. Air- Cooled Condenser. ACH, ACX, ACL Vintage A. Replacement Parts List No Revision C 10/2016 Replacement Parts List No. 700023300 Revision C 0/206 Daikin McQuay Air- Cooled Condenser ACH, ACX, ACL 04-225 Vintage A To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com

More information

Daikin McQuay. Roofpak Condensing Unit Medium Cabinet, Standalone Standard & Digital Compressor Models

Daikin McQuay. Roofpak Condensing Unit Medium Cabinet, Standalone Standard & Digital Compressor Models Replacement Parts List No. 7000600 Revision S 0/08 Daikin McQuay Roofpak Condensing Unit Medium Cabinet, Standalone Standard & Digital Compressor Models RCS 045-075 Tons Vintage D Code = A, A, YA Unit

More information

McQuay. Cabinet Unit Heater. CHB, CHF Vintage A. FCHB, FCHF Design A (1) Last Manufactured: 2010

McQuay. Cabinet Unit Heater. CHB, CHF Vintage A. FCHB, FCHF Design A (1) Last Manufactured: 2010 Replacement Parts List No. 055211700 Revision G 05/2017 McQuay Cabinet Unit Heater CHB, CHF 003-015 Vintage A FCHB, FCHF 03-15 Design A (1) Last Manufactured: 2010 To find your Daikin Applied parts distributor,

More information

McQuay. Seasonpak Reciprocating Chiller. WHR Vintage C. Last Manufactured: Replacement Parts List No Revision I 05/2016

McQuay. Seasonpak Reciprocating Chiller. WHR Vintage C. Last Manufactured: Replacement Parts List No Revision I 05/2016 Replacement Parts List No. 055224300 Revision I 05/2016 McQuay Seasonpak Reciprocating Chiller WHR 008-120 Vintage C Last Manufactured: 1998 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Westinghouse. Rooftop Heating and Cooling. IK 300 Vintage 0, 1, 2, 3, 4, 5. Last Manufactured: 1975

Westinghouse. Rooftop Heating and Cooling. IK 300 Vintage 0, 1, 2, 3, 4, 5. Last Manufactured: 1975 Replacement Parts List No. 055227900 Revision A 03/2003 Westinghouse Rooftop Heating and Cooling IK 300 Vintage 0,, 2, 3, 4, 5 Last Manufactured: 975 To find your Daikin Applied parts distributor, call

More information

McQuay. Water Source Heat Pump Replacement Chassis. VF Vintage H. Last Manufactured: 1992

McQuay. Water Source Heat Pump Replacement Chassis. VF Vintage H. Last Manufactured: 1992 Replacement Parts List No. 110502800 Revision A 02/2006 McQuay Water Source Heat Pump Replacement Chassis VF 100-330 Vintage H Last Manufactured: 1992 To find your Daikin Applied parts distributor, call

More information

Daikin McQuay. Roofpak Condensing Unit Small Cabinet, Standalone Standard & Digital Compressor Models

Daikin McQuay. Roofpak Condensing Unit Small Cabinet, Standalone Standard & Digital Compressor Models Replacement Parts List No. 70009700 Revision M 0/08 Daikin McQuay Roofpak Condensing Unit Small Cabinet, Standalone Standard & Digital Compressor Models RCS 05-040 Vintage D Code = A, A, YA Code 44= R,

More information

McQuay. Console Water Source Heat Pump. European Unit WWME, WWMJ, WWMK, WWML Designs A, B (1, 2) Last Manufactured: 2004

McQuay. Console Water Source Heat Pump. European Unit WWME, WWMJ, WWMK, WWML Designs A, B (1, 2) Last Manufactured: 2004 Replacement Parts List 110502500 Revision C 02/2017 McQuay Console Water Source Heat Pump European Unit WWME, WWMJ, WWMK, WWML 007-015 Designs A, B (1, 2) Last Manufactured: 2004 To find your Daikin Applied

More information

McQuay Climate Control. Commercial Unitary Rooftop. CUR Vintage F. Last Manufactured: 1996

McQuay Climate Control. Commercial Unitary Rooftop. CUR Vintage F. Last Manufactured: 1996 Replacement s List No. 055236800 Revision C 11/2016 McQuay Climate Control Commercial Unitary Rooftop CUR 075-150 Vintage F Last Manufactured: 1996 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 007, 009, 012 Design 4. Replacement Parts List No Revision L 02/2018

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 007, 009, 012 Design 4. Replacement Parts List No Revision L 02/2018 Replacement Parts List No. 700016100 Revision L 02/2018 Daikin McQuay Enfinity Horizontal Water Source Heat Pump WCCH, WCCW 007, 009, 012 Design 4 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Westinghouse. Rooftop Heating and Cooling. IK 180 Vintage 0, 1, 2, 3, 4. Last Manufactured: 1975

Westinghouse. Rooftop Heating and Cooling. IK 180 Vintage 0, 1, 2, 3, 4. Last Manufactured: 1975 Replacement Parts List No. 055227700 Revision A 03/2003 Westinghouse Rooftop Heating and Cooling IK 180 Vintage 0, 1, 2, 3, 4 Last Manufactured: 1975 To find your Daikin Applied parts distributor, call

More information

Centrifugal Chiller PE046, PE047, PE048, PE050 PEH PF083, PF096, PF105, PF116 PH PHH PL

Centrifugal Chiller PE046, PE047, PE048, PE050 PEH PF083, PF096, PF105, PF116 PH PHH PL Centrifugal Chiller PE046, PE047, PE048, PE050 PEH046-050 PF083, PF096, PF105, PF116 PH046-050 PHH046-050 PL-906-49 Unit ASSY. - Labels / 1987 to Present Unit ASSY. - Labels / 1987 to Present No. Index

More information

Centrifugal Chiller. PF/PFH Size: 063. Replacement Parts List No Revision V 05/2012

Centrifugal Chiller. PF/PFH Size: 063. Replacement Parts List No Revision V 05/2012 Replacement Parts List No. 057113900 Revision V 05/2012 Centrifugal Chiller PF/PFH Size: 063 To find your Daikin McQuay parts distributor, call 1-800-377-2787 or visit www.daikinmcquay.com Contents Parts

More information

McQuay Climate Control Singer

McQuay Climate Control Singer Replacement Parts List No. 55205400 Rev. B 09/2015 McQuay Climate Control Singer Large Vertical Water Source Heat Pump LGP, LHP, LWP 18, 22 Vintage A Last Manufactured: 1989 To find your Daikin Applied

More information

McQuay. Incremental. MEK, MHK Vintage A. PKES, PKHS, PRKC, PRKH Design A (1) Replacement Parts List No Revision G 07/2017

McQuay. Incremental. MEK, MHK Vintage A. PKES, PKHS, PRKC, PRKH Design A (1) Replacement Parts List No Revision G 07/2017 Replacement Parts List No. 057110000 Revision G 07/2017 McQuay Incremental MEK, MHK 019-022 Vintage A PKES, PKHS, PRKC, PRKH 019-022 Design A (1) To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Enfinity Ceiling Mounted Water Source Heat Pump. WCCH, WCCW 019, 024 Design 1. Last Manufactured: 2008

McQuay. Enfinity Ceiling Mounted Water Source Heat Pump. WCCH, WCCW 019, 024 Design 1. Last Manufactured: 2008 Replacement Parts List No. 700013300 Revision A 05/2017 McQuay Enfinity Ceiling Mounted Water Source Heat Pump WCCH, WCCW 019, 024 Design 1 Last Manufactured: 2008 To find your Daikin Applied parts distributor,

More information

Daikin McQuay. Global Scroll Compressor Air-Cooled Chiller. AGZ Vintage D Unit Revision 00, 0A (Code 55)

Daikin McQuay. Global Scroll Compressor Air-Cooled Chiller. AGZ Vintage D Unit Revision 00, 0A (Code 55) Replacement Parts List No. 70008600 Revision M /207 Daikin McQuay Global Scroll Compressor Air-Cooled Chiller AGZ 025-90 Vintage D Unit Revision 00, 0A (Code 55) To find your Daikin Applied parts distributor,

More information

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 042, 048, 060, 070 Design 5

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 042, 048, 060, 070 Design 5 Replacement Parts List No. 700027900 Revision M 09/2018 Daikin McQuay Enfinity Horizontal Water Source Heat Pump WCCH, WCCW 042, 048, 060, 070 Design 5 To find your Daikin Applied parts distributor, call

More information

McQuay. Large Capacity Fan Coil Belt Drive. SCB, SHB Vintage B. FCZA, FCZC, FCZH, FHZA, FHZC, FHZH S08 - S30 Design A (1)

McQuay. Large Capacity Fan Coil Belt Drive. SCB, SHB Vintage B. FCZA, FCZC, FCZH, FHZA, FHZC, FHZH S08 - S30 Design A (1) Replacement Parts List No. 055236400 Revision U 0/208 McQuay Large Capacity Fan Coil Belt Drive SCB, SHB 08-30 Vintage B FCZA, FCZC, FCZH, FHZA, FHZC, FHZH S08 - S30 Design A () To find your Daikin Applied

More information

McQuay. Enfinity Horizontal Water Source Heat Pump. WCRH, WCRW 007, 009, 012 Design 1. Replacement Parts List No Revision B 02/2018

McQuay. Enfinity Horizontal Water Source Heat Pump. WCRH, WCRW 007, 009, 012 Design 1. Replacement Parts List No Revision B 02/2018 Replacement Parts List No. 700011100 Revision B 02/2018 McQuay Enfinity Horizontal Water Source Heat Pump WCRH, WCRW 007, 009, 012 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay Climate Control Singer. Rooftop Unit. ER, R 250 Vintage C, D. Last Manufactured: Replacement Parts List No Revision C 04/2002

McQuay Climate Control Singer. Rooftop Unit. ER, R 250 Vintage C, D. Last Manufactured: Replacement Parts List No Revision C 04/2002 Replacement Parts List No. 779200800 Revision C 04/2002 McQuay Climate Control Singer Rooftop Unit ER, R 250 Vintage C, D Last Manufactured: 1996 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Thinline Vertical Fan Coil Floor Mounted. TSF Vintage G. Last Manufactured: 1997

McQuay. Thinline Vertical Fan Coil Floor Mounted. TSF Vintage G. Last Manufactured: 1997 Replacement Parts List No. 057117400 Revision F 08/2016 McQuay Thinline Vertical Fan Coil Floor Mounted TSF 021-121 Vintage G Last Manufactured: 1997 To find your Daikin Applied parts distributor, call

More information

McQuay Climate Control Singer. Rooftop Unit. ER, R 080 Vintage A, B, C, D. Last Manufactured: 1996

McQuay Climate Control Singer. Rooftop Unit. ER, R 080 Vintage A, B, C, D. Last Manufactured: 1996 Replacement Parts List No. 779200300 Revision C 04/2011 McQuay Climate Control Singer Rooftop Unit ER, R 080 Vintage A, B, C, D Last Manufactured: 1996 To find your Daikin Applied parts distributor, call

More information

McQuay Climate Control Singer. Rooftop Unit. ER, R 160 Vintage A, B, C, D. Last Manufactured: 1996

McQuay Climate Control Singer. Rooftop Unit. ER, R 160 Vintage A, B, C, D. Last Manufactured: 1996 Replacement Parts List No. 779200600 Revision B 07/2007 McQuay Climate Control Singer Rooftop Unit ER, R 160 Vintage A, B, C, D Last Manufactured: 1996 To find your Daikin Applied parts distributor, call

More information

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 048, 060, 070 Design 1. Replacement Parts List No Revision C 10/2016

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 048, 060, 070 Design 1. Replacement Parts List No Revision C 10/2016 Replacement Parts List No. 700011400 Revision C 10/2016 McQuay Ceiling Mounted Water Source Heat Pump WCRH, WCRW 048, 060, 070 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Ceiling Concealed Water Source Heat Pump. CCH, CCG, CCW 015, 019 Vintage A. Last Manufactured: 1995

McQuay. Ceiling Concealed Water Source Heat Pump. CCH, CCG, CCW 015, 019 Vintage A. Last Manufactured: 1995 Replacement Parts List No. 55235700 Revision C 08/2017 McQuay Ceiling Concealed Water Source Heat Pump CCH, CCG, CCW 015, 019 Vintage A Last Manufactured: 1995 To find your Daikin Applied parts distributor,

More information

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 030, 036, 042 Design 1. Replacement Parts List No Revision B 10/2016

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 030, 036, 042 Design 1. Replacement Parts List No Revision B 10/2016 Replacement Parts List No. 700011300 Revision B 10/2016 McQuay Ceiling Mounted Water Source Heat Pump WCRH, WCRW 030, 036, 042 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay Air Cooled Chiller AWS280A, AWS300A, AWS320A, AWS350A PL

McQuay Air Cooled Chiller AWS280A, AWS300A, AWS320A, AWS350A PL McQuay Air Cooled Chiller 280A, 300A, 320A, 350A PL-1008-7 280A / 300A / 320A / 350A 1 280A / 300A / 320A / 350A 2 280A / 300A / 320A / 350A 3 280A / 300A / 320A / 350A 4 280A / 300A / 320A / 350A 5 280A

More information

McQuay. HiLine Fan Coil. HSB Vintage B. Last Manufactured: Replacement Parts List No Revision C 09/2016

McQuay. HiLine Fan Coil. HSB Vintage B. Last Manufactured: Replacement Parts List No Revision C 09/2016 Replacement Parts List No. 055211200 Revision C 09/2016 McQuay HiLine Fan Coil HSB 030-120 Vintage B Last Manufactured: 1990 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit

More information

Daikin McQuay. Enfinity Vertical Water Source Heat Pump. WVFC, WVFW Design 1. Replacement Parts List No Revision S 01/2018

Daikin McQuay. Enfinity Vertical Water Source Heat Pump. WVFC, WVFW Design 1. Replacement Parts List No Revision S 01/2018 Replacement Parts List No. 700012100 Revision S 01/2018 Daikin McQuay Enfinity Vertical Water Source Heat Pump WVFC, WVFW 009-070 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Centrifugal Chiller Single Compressor WSC087, TSC087, HSC087 PL

Centrifugal Chiller Single Compressor WSC087, TSC087, HSC087 PL Centrifugal Chiller Single Compressor WSC087, TSC087, HSC087 PL-906-43 Nomenclature Nomenclature No. Index Parts No. Parts Name Drwg. No. Parts Model & Specifi cation Q ty/unit Wiring Symbol Notes END

More information

Daikin. SmartSource Compact Vertical Water Source Heat Pump. WGCV 048, 060, 070 Design 1. Replacement Parts List No Revision D 01/2018

Daikin. SmartSource Compact Vertical Water Source Heat Pump. WGCV 048, 060, 070 Design 1. Replacement Parts List No Revision D 01/2018 Replacement Parts List No. 700052400 Revision D 01/2018 Daikin SmartSource Compact Vertical Water Source Heat Pump WGCV 048, 060, 070 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin. PreciseLine Horizontal Large Capacity Blower Coil. BCHD Design 1. Replacement Parts List No Revision A 03/2019

Daikin. PreciseLine Horizontal Large Capacity Blower Coil. BCHD Design 1. Replacement Parts List No Revision A 03/2019 Replacement Parts List No. 700053700 Revision A 03/2019 Daikin PreciseLine Horizontal Large Capacity Blower Coil BCHD 030-050 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

ComfortPac 42 x 16. PTAC, PTHP Sizes Design C (3) Replacement Parts List No Rev. J 2/2012

ComfortPac 42 x 16. PTAC, PTHP Sizes Design C (3) Replacement Parts List No Rev. J 2/2012 Replacement Parts List No. 700006200 Rev. J 2/2012 ComfortPac 42 x 16 PTAC, PTHP Sizes 07- Design C (3) To find your McQuay parts distributor, call 1-800-377-2787 or visit www.mcquay.com Table of Contents

More information

Daikin McQuay. Large Capacity Fan Coil Belt Drive. HCBB, HHBB Design 1. Replacement Parts List No Revision E 03/2018

Daikin McQuay. Large Capacity Fan Coil Belt Drive. HCBB, HHBB Design 1. Replacement Parts List No Revision E 03/2018 Replacement s List No. 700024000 Revision E 03/2018 Daikin McQuay Large Capacity Fan Coil Belt Drive HCBB, HHBB 08-30 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit

More information

McQuay. Seasonmaker Horizontal Fan Coil. TSC Vintage G. Last Manufactured: Replacement Parts List No Revision C 08/2016

McQuay. Seasonmaker Horizontal Fan Coil. TSC Vintage G. Last Manufactured: Replacement Parts List No Revision C 08/2016 Replacement Parts List 057117500 Revision C 08/2016 McQuay Seasonmaker Horizontal Fan Coil TSC 021-121 Vintage G Last Manufactured: 1997 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Air Cooled Screw Compressor Chiller. ALS Vintage C. Last Manufactured: Replacement Parts List No Revision E 09/2016

McQuay. Air Cooled Screw Compressor Chiller. ALS Vintage C. Last Manufactured: Replacement Parts List No Revision E 09/2016 Replacement Parts List No. 700011500 Revision E 09/2016 McQuay Air Cooled Screw Compressor Chiller ALS 141-218 Vintage C Last Manufactured: 2006 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Centrifugal Chiller Single Compressor WSC048, WSC050 TSC048, TSC050 HSC048, HSC050 PL

Centrifugal Chiller Single Compressor WSC048, WSC050 TSC048, TSC050 HSC048, HSC050 PL Centrifugal Chiller Single Compressor WSC048, WSC050 TSC048, TSC050 HSC048, HSC050 PL-906-47 Nomenclature Nomenclature END VIEW- MICROTECH 200 UNITS 6003231 UNIT DATAPLATE 070191901 UNITS WITH FACTORY

More information

ComfortPac 42 x 16. PTAC, PTHP Sizes Vintages B and B+ (2) Replacement Parts List No Rev. P 1/2012

ComfortPac 42 x 16. PTAC, PTHP Sizes Vintages B and B+ (2) Replacement Parts List No Rev. P 1/2012 Replacement Parts List No. 110511900 Rev. P 1/2012 ComfortPac 42 x 16 PTAC, PTHP Sizes 07-15 Vintages B and B+ (2) To find your McQuay parts distributor, call 1-800-377-2787 or visit www.mcquay.com Table

More information

McQuay. Central Station Air Handlers Low Pressure. LHD, LYF, LSL, LML, LWL Vintage C. LML, LSB Vintage E. Last Manufactured: 1999

McQuay. Central Station Air Handlers Low Pressure. LHD, LYF, LSL, LML, LWL Vintage C. LML, LSB Vintage E. Last Manufactured: 1999 Replacement Parts List No. 055222600 Revision F 11/2011 McQuay Central Station Air Handlers Low Pressure LHD, LYF, LSL, LML, LWL 103-228 Vintage C LML, LSB 106-111 Vintage E Last Manufactured: 1999 To

More information

Daikin. TrailBlazer Air-Cooled Scroll Chiller. AGZ Vintage E Unit Revision 00. Replacement Parts List No Revision P 10/2018

Daikin. TrailBlazer Air-Cooled Scroll Chiller. AGZ Vintage E Unit Revision 00. Replacement Parts List No Revision P 10/2018 Replacement Parts List No. 700028500 Revision P 0/208 Daikin TrailBlazer Air-Cooled Scroll Chiller AGZ 030-070 Vintage E Unit Revision 00 To find your Daikin Applied parts distributor, call -800-377-2787

More information

McQuay. Console Water Source Heat Pump. CWC, CWG, CWH, CWJ, CWK Vintage B. Last Manufactured: 1994

McQuay. Console Water Source Heat Pump. CWC, CWG, CWH, CWJ, CWK Vintage B. Last Manufactured: 1994 Replacement Parts List No. 057101700 Revision B 02/2017 McQuay Console Water Source Heat Pump CWC, CWG, CWH, CWJ, CWK 015-019 Vintage B Last Manufactured: 1994 To find your Daikin Applied parts distributor,

More information

Centrifugal Chiller PFH087 PL

Centrifugal Chiller PFH087 PL Centrifugal Chiller PFH087 PL-1003-17 Nomenclature 1 Unit Assy. Components Labels 2 Unit Assy. Components Labels No. Index Parts No. Parts Name Drwg. No. Parts Model & Specifi cation Q ty/unit PFH087 Wiring

More information

McQuay. Thermal Systems Absorption Chiller ME, MF Vintage A. Last Manufactured: Replacement Parts List No New 05/2001

McQuay. Thermal Systems Absorption Chiller ME, MF Vintage A. Last Manufactured: Replacement Parts List No New 05/2001 Replacement Parts List No. 1105050 New 05/2001 McQuay Thermal Systems Absorption Chiller ME, MF 21-33 Vintage A Last Manufactured: 1997 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Console Water Source Heat Pump. WMH, WMG, WMK, WCH, WCG 007, 009,012 Vintage B. Last Manufactured: 1998

McQuay. Console Water Source Heat Pump. WMH, WMG, WMK, WCH, WCG 007, 009,012 Vintage B. Last Manufactured: 1998 Replacement Parts List No. 057101600 Revision E 06/2015 McQuay Console Water Source Heat Pump WMH, WMG, WMK, WCH, WCG 007, 009,012 Vintage B Last Manufactured: 1998 To find your Daikin Applied parts distributor,

More information

McQuay. Air Cooled Screw Compressor Chiller. ALS Vintage C. Last Manufactured: Replacement Parts List No Revision G 09/2016

McQuay. Air Cooled Screw Compressor Chiller. ALS Vintage C. Last Manufactured: Replacement Parts List No Revision G 09/2016 Replacement Parts List No. 700011600 Revision G 09/2016 McQuay Air Cooled Screw Compressor Chiller ALS 245-295 Vintage C Last Manufactured: 2006 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Global Air-Cooled Screw Compressor Chiller. AGS (60 Hertz) (50 Hertz) Vintage B. Last Manufactured: 2008

McQuay. Global Air-Cooled Screw Compressor Chiller. AGS (60 Hertz) (50 Hertz) Vintage B. Last Manufactured: 2008 Replacement Parts List No. 700007900 Revision H 12/2017 McQuay Global Air-Cooled Screw Compressor Chiller AGS 230-475 (60 Hertz) 206-411 (50 Hertz) Vintage B Last Manufactured: 2008 To find your Daikin

More information

Daikin. Magnitude TM Magnetic Bearing Centrifugal Chiller. WME 0501S, 0502S, 0701S, 0702S Vintage B

Daikin. Magnitude TM Magnetic Bearing Centrifugal Chiller. WME 0501S, 0502S, 0701S, 0702S Vintage B Replacement Parts List No. 0700053000 Revision C 02/2018 Daikin Magnitude TM Magnetic Bearing Centrifugal Chiller WME 0501S, 0502S, 0701S, 0702S Vintage B To find your Daikin Applied parts distributor,

More information

Centrifugal Chiller PEH087 PL

Centrifugal Chiller PEH087 PL Centrifugal Chiller PEH087 PL-906-39 Unit Assy. - Unit Labels Unit Assy. - Unit Labels No. Index Parts No. Parts Name Drwg. No. Parts Model & Specifi cation Q ty/unit Wiring Symbol Notes 931 6006215 LABEL

More information

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision B 03/2016

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision B 03/2016 Replacement s List 70002400 Revision B 03/206 Daikin McQuay Large Capacity Fan Coil Direct Drive HCDB, HHDB 06-20 Design To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com

More information

McQuay. Self-Contained Variable and Constant Air Volume. SWP Vintage F. Replacement Parts List No Revision G 04/2018

McQuay. Self-Contained Variable and Constant Air Volume. SWP Vintage F. Replacement Parts List No Revision G 04/2018 Replacement Parts List No. 700006000 Revision G 04/208 McQuay Self-Contained Variable and Constant Air Volume SWP 08-095 Vintage F To find your Daikin Applied parts distributor, call -800-377-2787 or visit

More information

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW Design 1. Replacement Parts List No Revision I 12/2015

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW Design 1. Replacement Parts List No Revision I 12/2015 Replacement Parts List No. 700014800 Revision I 12/2015 Daikin McQuay Vertical Stack Water Source Heat Pump WVHC, WVHF, WVHW 009-036 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin. Trailblazer Air-Cooled Scroll Chiller. AGZ Vintage E Unit Revision 00. Replacement Parts List No Revision C 11/2015

Daikin. Trailblazer Air-Cooled Scroll Chiller. AGZ Vintage E Unit Revision 00. Replacement Parts List No Revision C 11/2015 Replacement Parts List No. 700050800 Revision C /205 Daikin Trailblazer Air-Cooled Scroll Chiller AGZ 075-80 Vintage E Unit Revision 00 To find your Daikin Applied parts distributor, call -800-377-2787

More information

McQuay Climate Control. Horizontal Water Source Heat Pump. CC, CG, CW Vintage C, D. Last Manufactured: 1986

McQuay Climate Control. Horizontal Water Source Heat Pump. CC, CG, CW Vintage C, D. Last Manufactured: 1986 Replacement Parts List No. 05520400 Revision D 01/2017 McQuay Climate Control Horizontal Water Source Heat Pump CC, CG, CW 0750-1000 Vintage C, D Last Manufactured: 1986 To find your Daikin Applied parts

More information

Daikin. Magnitude Magnetic Bearing Compressor Centrifugal Chiller. WMC 400D Vintage C. Replacement Parts List No Revision B 10/2015

Daikin. Magnitude Magnetic Bearing Compressor Centrifugal Chiller. WMC 400D Vintage C. Replacement Parts List No Revision B 10/2015 Replacement Parts List No. 700029500 Revision B 10/2015 Daikin Magnitude Magnetic Bearing Compressor Centrifugal Chiller WMC 400D Vintage C To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Commercial 3 Ton Direct Drive Package Cooling Unit. nufacturing Company, L.P San Felipe, Suite 500

Commercial 3 Ton Direct Drive Package Cooling Unit. nufacturing Company, L.P San Felipe, Suite 500 REPAIR PARTS Commercial 3 Ton Direct Drive Package Cooling Unit DCC036XXX1DXXAAA DCC036XXX1DXXXAA DCC036XXX1DXXXAB DCC036XXX3DHXXAA DCC036XXX3DHXXAB DCC036XXX3DXXXAA DCC036XXX3DXXXAB nufacturing Company,

More information

McQuay Westinghouse. Centrifugal Chiller PF, PFH 063. Last Manufactured: Replacement Parts List No Revision AB 06/2018

McQuay Westinghouse. Centrifugal Chiller PF, PFH 063. Last Manufactured: Replacement Parts List No Revision AB 06/2018 Replacement Parts List No. 57113900 Revision AB 06/2018 McQuay Westinghouse Centrifugal Chiller PF, PFH 063 Last Manufactured: 2002 To find your Daikin Applied parts distributor, call 1-800-377-2787 or

More information

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1 Replacement Parts List No. 700024700 Revision O 10/2018 Daikin Daikin McQuay SmartSource Single Stage Horizontal Water Source Heat Pump WGSH 007, 009, 012 Design 1 To find your Daikin Applied parts distributor,

More information

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision C 03/2018

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision C 03/2018 Replacement s List 700024100 Revision C 03/2018 Daikin McQuay Large Capacity Fan Coil Direct Drive HCDB, HHDB 06-20 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit

More information

Daikin. Magnitude Magnetic Bearing Compressor Centrifugal Chiller. WMC 125S, 145S, 200S 145D, 150D, 225D, 250D, 275D, 290D Vintage C

Daikin. Magnitude Magnetic Bearing Compressor Centrifugal Chiller. WMC 125S, 145S, 200S 145D, 150D, 225D, 250D, 275D, 290D Vintage C Replacement Parts List No. 700029400 Revision F 10/2017 Daikin Magnitude Magnetic Bearing Compressor Centrifugal Chiller WMC 125S, 145S, 200S 145D, 150D, 225D, 250D, 275D, 290D Vintage C To find your Daikin

More information

McQuay. Magnitude Magnetic Bearing Centrifugal Chiller WMC 035T. Last Manufactured: Replacement Parts List No Revision J 12/2017

McQuay. Magnitude Magnetic Bearing Centrifugal Chiller WMC 035T. Last Manufactured: Replacement Parts List No Revision J 12/2017 Replacement Parts List No. 700005800 Revision J 12/2017 McQuay Magnitude Magnetic Bearing Centrifugal Chiller WMC 035T Last Manufactured: 2008 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Console Water Source Heat Pump. Replacement Parts List No Revision Q 07/2016

McQuay. Console Water Source Heat Pump. Replacement Parts List No Revision Q 07/2016 Replacement Parts List 110502400 Revision Q 07/2016 McQuay Console Water Source Heat Pump WWAF,WWAG,WWAH,WWAS,WWAX,WWCQ WWDA,WWDB,WWDD,WWDE,WWDF,WWDG,WWDH, WWDJ,WWDN,WWDS,WWFQ,WWLA,WWLB,WWLC,WWLL, WWMA,WWMB,WWMC,WWMD,WWMF,WWMG,WWMH,

More information

Daikin. TrailBlazer Air-Cooled Scroll Chiller. AMZ Vintage A. Replacement Parts List No Revision C 01/2018

Daikin. TrailBlazer Air-Cooled Scroll Chiller. AMZ Vintage A. Replacement Parts List No Revision C 01/2018 Replacement Parts List No. 700052900 Revision C 0/208 Daikin TrailBlazer Air-Cooled Scroll Chiller AMZ 00-040 Vintage A To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com

More information

Daikin. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW Design 2. Replacement Parts List No Revision F 04/2018

Daikin. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW Design 2. Replacement Parts List No Revision F 04/2018 Replacement Parts List No. 700050900 Revision F 04/2018 Daikin Enfinity Horizontal Water Source Heat Pump WCCH, WCCW 072-120 Design 2 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay Air Cooled Chiller AWS175A, AWS190A, AWS210A, AWS230A, AWS250A AWS280A, AWS300A, AWS320A, AWS350A, AWS380A, AWS405A PL

McQuay Air Cooled Chiller AWS175A, AWS190A, AWS210A, AWS230A, AWS250A AWS280A, AWS300A, AWS320A, AWS350A, AWS380A, AWS405A PL McQuay Air Cooled Chiller AWS175A, AWS190A, AWS210A, AWS230A, AWS250A AWS280A, AWS300A, AWS320A, AWS350A, AWS380A, AWS405A PL-1007-3 AWS175A / AWS190A / AWS210A / AWS230A / AWS250A / AWS280A / AWS300A

More information

McQuay Climate Control. Water Source Heat Pump. CC, CG Vintage E, F, G. Last Manufactured: 1986

McQuay Climate Control. Water Source Heat Pump. CC, CG Vintage E, F, G. Last Manufactured: 1986 Replacement Parts List No. 110508600 Revision C 12/2008 McQuay Climate Control Water Source Heat Pump CC, CG 750-1000 Vintage E, F, G Last Manufactured: 1986 To find your Daikin Applied parts distributor,

More information

McQuay. Magnitude Water-Cooled Magnetic Bearing Centrifugal Chiller. WMC 150 Vintage A. Last Manufactured: 2005

McQuay. Magnitude Water-Cooled Magnetic Bearing Centrifugal Chiller. WMC 150 Vintage A. Last Manufactured: 2005 Replacement Parts List No. 700005500 Revision J 10/2017 McQuay Magnitude Water-Cooled Magnetic Bearing Centrifugal Chiller WMC 150 Vintage A Last Manufactured: 2005 To find your Daikin Applied parts distributor,

More information

Daikin Daikin McQuay. SmartSource Single Stage Vertical Water Source Heat Pump. WGSV 007, 009, 012 Design 1

Daikin Daikin McQuay. SmartSource Single Stage Vertical Water Source Heat Pump. WGSV 007, 009, 012 Design 1 Replacement Parts List No. 700029600 Revision L 11/2017 Daikin Daikin McQuay SmartSource Single Stage Vertical Water Source Heat Pump WGSV 007, 009, 012 Design 1 To find your Daikin Applied parts distributor,

More information

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage D. LML, LSB, MMM, MSB Vintage E

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage D. LML, LSB, MMM, MSB Vintage E Replacement Parts List No. 046902100 Revision D 01/2015 McQuay Central Station Air Handler LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL 137-172 Vintage D LML, LSB, MMM, MSB 137-172 Vintage E Last Manufactured:

More information

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage C. Last Manufactured: 1984

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage C. Last Manufactured: 1984 Replacement Parts List No. 055222700 Revision D 0/205 McQuay Central Station Air Handler LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL 37-72 Vintage C Last Manufactured: 984 To find your Daikin Applied parts

More information

Daikin. Trailblazer Air-Cooled Scroll Chiller. AGZ Vintage E Unit Revision 00. Replacement Parts List No Revision N 02/2018

Daikin. Trailblazer Air-Cooled Scroll Chiller. AGZ Vintage E Unit Revision 00. Replacement Parts List No Revision N 02/2018 Replacement Parts List No. 700050800 Revision N 02/208 Daikin Trailblazer Air-Cooled Scroll Chiller AGZ 075-80 Vintage E Unit Revision 00 To find your Daikin Applied parts distributor, call -800-377-2787

More information

nufacturing Company, L.P San Felipe, Suite 500

nufacturing Company, L.P San Felipe, Suite 500 REPAIR PARTS Commercial 10 Ton Package Cooling Units DCC1200304BHXBAA DCC120XXX3BXXXAA DCC120XXX4BXXXAA DCC120XXX4BXXXAB DCC120XXX7BXXXAA nufacturing Company, L.P. 5151 San Felipe, Suite 500 www.amana-hac.com

More information

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1 Replacement Parts List No. 700024700 Revision M 11/2017 Daikin Daikin McQuay SmartSource Single Stage Horizontal Water Source Heat Pump WGSH 007, 009, 012 Design 1 To find your Daikin Applied parts distributor,

More information

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL REPLACEMENT PARTS MANUAL WALL MOUNTED PACKAGED AIR CONDITIONER Models: W1AA-A WAA-A WAA-B WAA-C WAA-D WAA-F General Notes Revised and/or additional pages may be issued from time to time. A complete and

More information

McQuay Westinghouse. Centrifugal Chiller PFH 087. Last Manufactured: Replacement Parts List No Revision P 04/2016

McQuay Westinghouse. Centrifugal Chiller PFH 087. Last Manufactured: Replacement Parts List No Revision P 04/2016 Replacement Parts List No. 57114200 Revision P 04/2016 McQuay Westinghouse Centrifugal Chiller PFH 087 Last Manufactured: 2002 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit

More information

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW 036 Design 2. Replacement Parts List No Revision A 12/2015

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW 036 Design 2. Replacement Parts List No Revision A 12/2015 Replacement Parts List No. 700050700 Revision A 12/2015 Daikin McQuay Vertical Stack Water Source Heat Pump WVHC, WVHF, WVHW 036 Design 2 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

AAF. Console Water Source Heat Pump. CWC, CWG, CWH, CWJ, CWK Vintage B. Last Manufactured: 1994

AAF. Console Water Source Heat Pump. CWC, CWG, CWH, CWJ, CWK Vintage B. Last Manufactured: 1994 Replacement Parts List No. 057101500 Revision B 02/2017 AAF Console Water Source Heat Pump CWC, CWG, CWH, CWJ, CWK 006-012 Vintage B Last Manufactured: 1994 To find your Daikin Applied parts distributor,

More information

nufacturing Company, L.P San Felipe, Suite 500

nufacturing Company, L.P San Felipe, Suite 500 Commercial 20 Ton Package Gas Units DCG2404003BAXAAA DCG2404003BXXXAA DCG2404004BXXXAA DCG2404004BXXXAB DCG2404007BXXXAA REPAIR PARTS nufacturing Company, L.P. 5151 San Felipe, Suite 500 www.amana-hac.com

More information

McQuay. Two-Stage Centrifugal Chiller WTC 700. Replacement Parts List No Revision B 07/2017

McQuay. Two-Stage Centrifugal Chiller WTC 700. Replacement Parts List No Revision B 07/2017 Replacement Parts List No. 700014000 Revision B 07/2017 McQuay Two-Stage Centrifugal Chiller WTC 700 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.daikinapplied.com Table

More information

Applied Decentralized Products Water Source Heat Pump / Rev.A HWH024D, HWH030D HWW024D, HWW030D PL

Applied Decentralized Products Water Source Heat Pump / Rev.A HWH024D, HWH030D HWW024D, HWW030D PL Applied Decentralized Products Water Source Heat Pump / Rev.A HWH, HWH HWW, HWW PL-1101-4 Nomenclature Nomenclature Field Installed Thermostats & Subbases For Mark IV/AC Control Units Code 03 must be M.

More information

Daikin. Magnitude Magnetic Bearing Compressor Centrifugal Chiller. WMC 350D, 400D Vintage C. Replacement Parts List No Revision F 10/2017

Daikin. Magnitude Magnetic Bearing Compressor Centrifugal Chiller. WMC 350D, 400D Vintage C. Replacement Parts List No Revision F 10/2017 Replacement Parts List No. 700029500 Revision F 10/2017 Daikin Magnitude Magnetic Bearing Compressor Centrifugal Chiller WMC 350D, 400D Vintage C To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw Air-to-Water Reverse Cycle Heat Pumps VLH 504 to 1204 126 to 294 kw 133 to 307 kw Technical Brochure TM VLH-N.3GB Date : June 2005 Supersedes : TM VLH-N.2GB/07.04 Specifications Advantages Range extension

More information

Daikin McQuay. VAV Air Terminal Unit MQ FCI6, FVI5, THI5. Replacement Parts List No Revision J 07/2017

Daikin McQuay. VAV Air Terminal Unit MQ FCI6, FVI5, THI5. Replacement Parts List No Revision J 07/2017 Replacement Parts List No. 700020000 Revision J 07/2017 Daikin McQuay VAV Air Terminal Unit MQ FCI6, FVI5, THI5 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.daikinapplied.com

More information

McQuay. Vertical Water Source Heat Pump. FCV, FCG & FCW 036 & 042 Vintage B. WFDD, WFDE, WFDG, WFDL WFDS, WFME, WFMS 036 & 042 Design A (1)

McQuay. Vertical Water Source Heat Pump. FCV, FCG & FCW 036 & 042 Vintage B. WFDD, WFDE, WFDG, WFDL WFDS, WFME, WFMS 036 & 042 Design A (1) Replacement Parts List 057103500 Revision P 03/2016 McQuay Vertical Water Source Heat Pump FCV, FCG & FCW 036 & 042 Vintage B WFDD, WFDE, WFDG, WFDL WFDS, WFME, WFMS 036 & 042 Design A (1) WFDA, WFDD,

More information

McQuay. Two-Stage Centrifugal Chiller WTC 500. Replacement Parts List No Revision A 10/2011

McQuay. Two-Stage Centrifugal Chiller WTC 500. Replacement Parts List No Revision A 10/2011 Replacement Parts List No. 700019800 Revision A 10/2011 McQuay Two-Stage Centrifugal Chiller WTC 500 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.daikinapplied.com Table

More information

MODELS YCAL0019, 0022, 0028, 0033, 0043, 0046, 0052, 0056, AND 0066

MODELS YCAL0019, 0022, 0028, 0033, 0043, 0046, 0052, 0056, AND 0066 AIR-COOLED LIQUID CHILLERS HERMETIC SCROLL Renewal Parts Supercedes: 50.67-RP (30) Form: 50.67-RP (5) MODELS YCAL009, 00, 008, 0033, 0043, 0046, 005, 0056, AND 0066 5009 STYLE "E" R-40A 5-60 TON 53-8 Kw

More information