Daikin. Trailblazer Air-Cooled Scroll Chiller. AGZ Vintage E Unit Revision 00. Replacement Parts List No Revision C 11/2015

Size: px
Start display at page:

Download "Daikin. Trailblazer Air-Cooled Scroll Chiller. AGZ Vintage E Unit Revision 00. Replacement Parts List No Revision C 11/2015"

Transcription

1 Replacement Parts List No Revision C /205 Daikin Trailblazer Air-Cooled Scroll Chiller AGZ Vintage E Unit Revision 00 To find your Daikin Applied parts distributor, call or visit

2 Contents Parts List Revision History...3 Serial Number Nomenclature...4 Unit Model Nomenclature Electrical Legend Unit Controls Refrigeration Circuit Compressor Layout Diagrams...2 Compressors AGZ AGZ AGZ AGZ AGZ 70, Evaporator...8 Evaporator Insulation...9 Liquid Line Piping Discharge Line Piping...22 Suction Line Piping...23 Hot Gas Bypass Piping...24 Sensor & Transducer Location Miscellaneous Components...27 Condenser Section Fan Motor and Fan Deck Diagram Condenser Coils...29 Coil Grilles and Coil Louvers...30 Base Grilles Base Louvers Optional Equipment Critical Parts List...CPL Air-Cooled Scroll Chiller, AGZ , Vintage E, Unit Rev. 00 Rev. C /5 RPL / Page 2

3 Parts List Revision History Revision Date Description NEW 3/205 New A 6/205 Page 5-7: Updated Unit Model Nomenclature. Page 0: Added Control Box Label example. Page : Added new page for common Unit Controls. Page 6: Added info for Size 6. Page 7: Removed info for Size 60. Page 8: Added Water Flow Sensor Adapter. Page 27: Added Sound Blanket info for Size 6, removed info for Size 60. Page 34: Corrected part #s for Base Louver Kits, were , 707, 708. Page 35: Added Water Flow Sensor Adapter. CPL: Added page for Critical Parts List. B 6/205 Page 22: Corrected description for , was "Harness, Discharge Solenoid". Page 3: Corrected Ref. Bubbles for all sizes.. Page 32: Corrected Qty. for Ref. W6 and removed Ref. W62. Page 33: Corrected Ref. Bubbles for Sizes Page 34: Corrected Part Numbers and Quantities for all Base Louver-Sides. C /205 Page 8: Corrected part #s for Ref. 00, was for all sizes; and Ref. 002, was for all sizes. Page 26: Updated all Sensors, were , 03. Page 29: Added part #s for Condenser Coils. Page 35: Corrected descriptions for Control Box Exhaust Fan & Control Box Heater Kits, were High Ambient and Low Ambient Kits. Added HGBP Kit note about T4 Kit. CPL: Updated Temp Sensor part #, was Daikin Applied, 3600 Industrial Park Blvd., P.O. Box 55, Minneapolis, MN (763) Air-Cooled Scroll Chiller, AGZ , Vintage E, Unit Rev. 00 Rev. C /5 RPL / Page 3

4 Serial Number Nomenclature STN U Plant Identification STN = Staunton, VA Sequence Number U = Unit Year of Manufacture 4 = = 205 etc. Month of Manufacture 0 = January 08 = August 02 = February 09 = September 03 = March 0 = October 04 = April = November 05 = May 2 = December 06 = June 07 = July Air-Cooled Scroll Chiller, AGZ , Vintage E, Unit Rev. 00 Rev. C /5 RPL / Page 4

5 Unit Model Nomenclature Code AGZ 075E D SE NN ST S M AL Y 27 MN N N N N NN N N Y N N UC B E L Code Code F N NN N NN NNNN N N N N N Y NNNN NN NN E N DSU DPN Y NNNN NON NNNN NNN D00 D2 J S NN Y S Unit Type AGZ = Air-Cooled Scroll Compressor Chiller 2 Unit Size & Vintage 075E - 00E = 6 Fan, 2 Circuit Units 0E - 30E = 8 Fan, 2 Circuit Units 40E - 80E = 0 Fan, 2 Circuit Units 3 Compressors D = 2 Compressors per Circuit T = 3 Compressors per Circuit 4 Platform SE = Standard Package - Std. Efficiency HE = Standard Packeage - High Efficiency SD = Std. Eff. Package w/desuperheaters Piping HD = High Eff. Package w/desuperheaters Piping 5 Construction NN = Unpainted Base w/o Unit Wraps FN= Fully Painted Base w/o Wraps 6 Sound ST = Standard Sound SB = Sound Reduction Compressor Blankets 7 Unit Operation K = Standard Operation (5F - 65F LWT) S = Standard Operation (40F - 50F LWT) A = Lower Operation (34F - 39F LWT) B = Lower Operation (5F - 33F LWT) 8 Condenser Coil Fins M = MicroChannel (standard) P = MicroChannel (Electro Fin Coating) 9 Compressor Starter AL = Across the Line 0 Future Voltage 2 = 208V / 60Hz / 3PH 29 = 230V / 60Hz / 3PH 46 = 380V / 60Hz / 3PH 27 = 460V / 60Hz / 3PH 37 = 575V / 60Hz / 3PH 52 = 400V / 50Hz / 3PH (De-rated 60 Hz unit) 2 Power Connection PC = Single Pt Pwr Blk & Ckt Protection DC = Single Pt Disc Switch & Ckt Protection DH = HSCC w/sgl Pt Disc Switch & Ckt Protection MN = Multiple Pt Pwr Blk & /3 Ckt Protection WN =Multiple Pt Disc Switches & /3 Ckt Protection 3 Phase Voltage N = None V = Phase & Over/Under Volt Protection w/led 4 Future 5 Control Box Ambient N = None H = With Exhaust Fans & Vents 6 Compressor Capacitor N = None - Std. 7 Communication NN = None LN = LonMark MN = Mod Bus BN = BACnet MSTP EN = BACnet IP NA = D-net LA = D-net & LonMark MA = D-net & Mod Bus BA = D-net & BACnet MSTP EA = D-net & BACnet IP 8 Display Options N = On Controller Only U = Unit Remote Display 9 Ground Fault N = None G = With Ground Fault Protection for the Unit 20 Future 2 Unit Options N = No unit options C = 5V Convenience Outlet (Unit Supplied Power) 22 Water Flow N = No Water Flow Indication A = Water Flow Indication on Evaporator only S = With Factory Installed Strainer B = With Factory Installed Strainer & Flow Indicator 23 Evaporator Connection UC = Universal Connection - Facing out back 24 Evaporator Insulation S = Sgl Layer Insulation to Suct Compr Tee B = Sgl Layer Insulation to Suct at each Compressor D = Dbl Layer Insul on Evap & Sgl Suct Piping 25 Unit Controls E = Electronic Expansion Valve 26 Fans L = Std Low Noise Fan Motors A = All Fan VFD w/standard Low Noise Fan Motors 27 Head Pressure F = Fantrol Only (32F Min.) D = VFD w/o Line Reactors V = VFD w/ Line Reactors B = VFD w/control Box Heaters L = VFD w/ Line Reactors & Control Box Heaters Air-Cooled Scroll Chiller, AGZ , Vintage E, Unit Rev. 00 Rev. C /5 RPL / Page 5

6 Unit Model Nomenclature Continued 28 Guards N = No Cond Coil Guards, No Base Guards G = Cond Coil Wire Grilles Only L = Cond Coil Louvers Only P = No Cond Coil Guards, with Base Wire Grilles R = No Cond Coil Guards, with Base Louvers F = Cond Coil & Base Wire Grilles C = Cond Coil Louvers & Base Wire Grilles B = Cond Coil & Base Louvers E = End Louvers Only 29 Tubing Options NN =Sealed Filt Drier, No Disch or Liq Valves, No HG VN = Repl Filter Drier, w/disch & Liq Valves, No HG NH = Sealed Filt Drier, No Disch or Liq Valves, w/hg VH = Repl Filter Drier, w/disch & Liq Valves, w/hg FH = Repl Filt Drier, w/dis & Liq Valves, w/hg Ready 30 Suction Valve N = No Valve V = With Shut-off Valve 3 Water Pump NN = None FE = Field Pwr - 3 HP Pump Mtr, RPM FG = Field Pwr - 5 HP Pump Mtr, RPM FH = Field Pwr HP Pump Mtr, RPM FJ = Field Pwr - 0 HP Pump Mtr, RPM FK = Field Pwr - 5 HP Pump Mtr, RPM FL = Field Pwr - 20 HP Pump Mtr, RPM FM = Field Pwr - 25 HP Pump Mtr, RPM FN = Field Pwr - 30 HP Pump Mtr, RPM UE = Unit Pwr - 3 HP Pump Mtr, RPM UG = Unit Pwr - 5 HP Pump Mtr, RPM UH = Unit Pwr HP Pump Mtr, RPM UJ = Unit Pwr - 0 HP Pump Mtr, RPM UK = Unit Pwr - 5 HP Pump Mtr, RPM UL = Unit Pwr - 20 HP Pump Mtr, RPM UM = Unit Pwr - 25 HP Pump Mtr, RPM UN = Unit Pwr - 30 HP Pump Mtr, RPM GE = Field Pwr - 3 HP Pump Mtr, RPM GG = Field Pwr - 5 HP Pump Mtr, RPM GH = Field Pwr HP Pump Mtr, RPM GJ = Field Pwr - 0 HP Pump Mtr, RPM GK = Field Pwr - 5 HP Pump Mtr, RPM GL = Field Pwr - 20 HP Pump Mtr, RPM GM = Field Pwr - 25 HP Pump Mtr, RPM GN= Field Pwr - 30 HP Pump Mtr, RPM VE = Unit Pwr - 3HP Pump Mtr, RPM VG = Unit Pwr - 5 HP Pump Mtr, RPM VH = Unit Pwr HP Pump Mtr, RPM VJ = Unit Pwr - 0HP Pump Mtr, RPM VK = Unit Pwr - 5 HP Pump Mtr, RPM VL = Unit Pwr - 20 HP Pump Mtr, RPM VM = Unit Pwr - 25 HP Pump Mtr, RPM VN= Unit Pwr - 30 HP Pump Mtr, RPM 32 Pump Type NNNN = No Pump Package PPZS = Pump Package Air Cooled Scroll Single Pump PPZD = Pump Package Air Cooled Scroll Dual PumP 34 Pump Flow 0000 = Determined by Rep based on conditions 35 Total Head 000 = Determined by Rep based on conditions 36 Pump Package Starter N = No Pump Package S = Pump Package Starter V = Pump Pkg VFD Starter w/o Line Reactors R = Pump Pkg VFD Starter w/ Line Reactors 37 Pump Gauges N = No Pressure Gauges G = Pressure Gauges 38 Pump Suction Valve N = No Pump Pkg Suction Shut-off Valve V = With Pump Pkg Suction Shut-off Valve 39 Pump Discharge Valve N = No Pump Pkg Discharge Shut-off Valve V = With Pump Pkg Discharge Shut-off Valve 40 Future 4 Impeller Trim NNNN = No Pumps 0000 = Impeller Size 42 Expansion Tank N = None 4 = Factory Installed - 4 Gallons 43 Buffer Tank NN = None 44 % of Glycol 000 = None E00 = Ethylene 00 = % (ex: E30 = 30% Ethylene) P00 = Propylene 00 = % (ex: P30 = 30% Propylene) 45 Pump # 0000 = None = With Pumps, Number determined by Selection Input 46 Approvals ETL AHRI ASHRAE Chicago A... None...None... None... None B...With...None...With...With C...With... With...With...With D...With...None...With... None E...With... With...With... None F...With...None... None...With V...With... With... None...With W...With... With... None... None Z...With...None... None... None 33 Pump Conn at Evap N = No Pump Package 2 = 2.5 Inch 3 = 3.0 Inch 4 = 4.0 Inch 8 = 8.0 inch Air-Cooled Scroll Chiller, AGZ , Vintage E, Unit Rev. 00 Rev. C /5 RPL / Page 6

7 Unit Model Nomenclature Continued 47 CRN Evaporator = CRN - British Columbia 2 = CRN - Alberta 3 = CRN - Saskatchewan 4 = CRN - Manitoba 5 = CRN - Ontario 6 = CRN - Quebec 7 = CRN - New Brunswick 8 = CRN - Nova Scotia 9 = CRN - Prince Edward Island 0 = CRN - Newfoundland U = CRN - Yukon N = CRN - No CRN required 48 Unit Start NSU = Startup by others DSU = Domestic, startup CSU = Canadian, startup ISU = International, No startup provided 49 Standard Warranty DPN = Domestic, -year std warranty - parts only CPN = Canadian, -year std warranty - parts only TPN = International, -year std warranty - parts only NON = None 50 Future 5 Extended Compressor Warranty NNNN = None CPE = Compressor Only - Ext year parts only CBE = Compressor Only - Ext year parts & labor CPE2 = Compressor Only - Ext 2 year parts only CBE2 = Compressor Only - Ext 2 year parts & labor CPE3 = Compressor Only - Ext 3 year parts only CBE3 = Compressor Only - Ext 3 year parts & labor CPE4 = Compressor Only - Ext 4 year parts only CBE4 = Compressor Only - Ext 4 year parts & labor 52 First Year Labor Warranty NON = None AC = Compessor Only AE = Entire Unit 54 Refrigerant Warranty NNN = No Refrigerant Warranty RA = yr. R40A refrigerant RA2 = 2 yr. R40A refrigerant RA3 = 3 yr. R40A refrigerant RA4 = 4 yr. R40A refrigerant RA5 = 5 yr. R40A refrigerant 55 Delay Warranty Start D00 = No Additional Months D02 = 2 Additional Months D04 = 4 Additional Months D06 = 6 Additional Months D08 = 8 Additional Months D0 = 0 Additional Months D2 = 2 Additional Months 56 Field Options S = Single Evap Pumps - Single Control Output D2 = Dual Evap Pumps - Dual Control Output 57 Brand Name J = Daikin 58 Ship S = Standard Ship R = Quick Ship 59 Restart NN = Standard RR = Rapid Restore 60 Future 6 Unit Misc. S = Standard Unit X = Special Unit 62 Unit Revision 00 = Original Revision 53 Extended Unit Warranty NNNN = None EPE = yr. Entire Unit- Parts Only EBE = yr. Entire Unit- Parts & Labor EPE2 = 2 yr. Entire Unit- Parts Only EBE2 = 2 yr. Entire Unit- Parts & Labor EPE3 = 3 yr. Entire Unit- Parts Only EBE3 = 3 yr. Entire Unit- Parts & Labor EPE4 = 4 yr. Entire Unit.- Parts Only EBE4 = 4 yr. Entire Unit- Parts & Labor DPE = yr. Entire Unit w/ Dual Pumps- Parts Only DBE = yr. Entire Unit w/ Dual Pumps- Parts & Labor DPE2 = 2 yr. Entire Unit w/ Dual Pumps- Parts Only DBE2 = 2 yr. Entire Unit w/ Dual Pumps- Parts & Labor DPE3 = 3 yr. Entire Unit w/ Dual Pumps- Parts Only DBE3 = 3 yr. Entire Unit w/ Dual Pumps- Parts & Labor DPE4 = 4 yr. Entire Unit w/ Dual Pumps- Parts Only DBE4 = 4 yr. Entire Unit w/ Dual Pumps- Parts & Labor SPE = yr. Entire Unit w/ Single Pumps- Parts Only SBE = yr. Entire Unit w/single Pumps- Parts & Labor SPE2 = 2 yr. Entire Unit w/ Single Pumps- Parts Only SBE2 = 2 yr. Entire Unit w/single Pumps- Parts & Labor SPE3 = 3 yr. Entire Unit w/ Single Pumps- Parts Only SBE3 = 3 yr. Entire Unit w/single Pumps- Parts & Labor SPE4 = 4 yr. Entire Unit w/ Single Pumps- Parts Only SBE4 = 4 yr. Entire Unit w/single Pumps- Parts & Labor Air-Cooled Scroll Chiller, AGZ , Vintage E, Unit Rev. 00 Rev. C /5 RPL / Page 7

8 Electrical Legend Schematic Sym. Description Location ABR Relay- Alarm Bell Control Box CB- 6 Circuit Breaker- Compressor Control Box CB00, 200 Circuit Breaker Control Box CC, 2 Circuit Controller (Controller Expansion Module) Control Box CT-GF, 2 Current Transformer- Ground Fault Control Box DS, 2 Disconnect- Main Control Box EEXV, 2 Expansion Valve Controller Control Box EXV, 2 Expansion Valve Liquid Line FAN, 2 Control Box Exhaust Fan Control Box FLO SWT Flow Switch- Evaporator Evaporator FU4, 5 Fuse- Primary, Control Transformer Control Box FU6, 6A Fuse- Secondary, Control Transformer Control Box FU7 Fuse- Evaporator Heater Control Box FU8 Fuse- Outlet Control Box FU-2 Fuse- Fan Circuit Control Box FU6 Fuse- Secondary, Control Transformer Control Box GF, 2 Relay- Ground Fault Control Box GND, 2 Ground Control Box HPR, 2 Switch - High Pressure Control Box HTR- 6 Heater- Compressor Compressors HTR7 Heater- Evaporator Control Box HTR8 Heater- Low Ambient Control Box Control Box LR, 2 Line Reactor- Fan Control Box M- 6 Contactor- Compressor/Pump Motor Control Box M- 6 Contactor- Fan Circuit # Control Box M2-26 Contactor- Fan Circuit #2 Control Box MPR, 2 Relay- Compressor Motor Protector Control Box MSP- 26 Motor Protector- Fan/Pump Motor Control Box MSP- 4 Motor Protector- Compressor Compressors OLF 5V Outlet Control Box PD Power Block- Main Control Box PD00, 200 Fan Power Distributor Block Control Box PS, 2 Switch- Pumpdown Control Box PVM, 2 Phase Voltage Monitor Control Box S00 Sensor- Leaving Water Temperature Evaporator S0 Low Pressure Transducer- Suction Circuit # Suction Line S02 Low Pressure Transducer- Suction Circuit #2 Suction Line S03 High Pressure Transducer- Discharge Circuit # Discharge Line S04 High Pressure Transducer- Discharge Circuit # 2 Discharge Line S05 Sensor- Outside Air Temperature Control Box S08 Sensor- Entering Water Temperature Evaporator S2 Sensor- Suction Temperature Circuit # Suction Line S3 Sensor- Suction Temperature Circuit #2 Suction Line SR, 2, 5, 6 Relay- Solenoid Control Box SR,2,2,22 Relay Control Box Air-Cooled Scroll Chiller, AGZ , Vintage E, Unit Rev. 00 Rev. C /5 RPL / Page 8

9 Electrical Legend, Continued Schematic Sym. Description Location SV Solenoid- Circuit # Liquid Line SV2 Solenoid- Circuit #2 Liquid Line SV5 Solenoid- Hot Gas Bypass Circuit # Hot Gas Bypass Line SV6 Solenoid- Hot Gas Bypass Circuit #2 Hot Gas Bypass Line SW Switch- Unit Shutoff Control Box T Transformer Control (20V Secondary) Control Box T2-6 Transformer Control (24V Secondary) Control Box TS Thermostat- Exhaust Fan Control Box TS2 Thermostat- Control Box Heater Control Box UC Unit Controller Control Box VFD, 2 VFD- Fan/Pump Motor Control Box Air-Cooled Scroll Chiller, AGZ , Vintage E, Unit Rev. 00 Rev. C /5 RPL / Page 9

10 Unit Controls For any control components not detailed on the following pages, refer to the Device ID label found inside the control panel (sample shown below) or contact Daikin Applied with the Control Box GOI number and/or the Unit GO number and Unit serial number. Device ID McQuay Part # Description Device ID McQuay Part # Description FU Fuse, Class CC, Time Delay, 600VAC, 5A, 200K AIC MBX_TL 2233 "Heyco Reducer Snap Bushing.5"" OD.062"" ID" FU Fuse Holder, Class CC & Midget (xfmr), 3 Pole, 30A, Ope... MBX_TL TEMPLATE, DRILLING, DOOR, SMALL, SINGLE DIS... FU Fuse Block Accessories, Fuse Puller, CC M, 30A MPR Relay, 20 VAC, 0A, DPDT FU Fuse, Midget, Time Delay, 500VAC, 30A, 0K AIC MPR Relay Socket, DIN Rail, Screw Terminal, 2 Pole FU6A Fuse, Midget, Time Delay, 500VAC, 5A, 0K AIC MPR Relay, 20 VAC, 0A, DPDT FU6A Fuse Block 2 Pole 30A 600V Midget MPR Relay Socket, DIN Rail, Screw Terminal, 2 Pole FU6A Fuse Block Accessories, Fuse Puller, CC M, 30A MSP CS MMP Class 0 Size S3 43 to 63A FU Fuse, Midget, Time Delay, 500VAC, 0A, 0K AIC MSP CS Link Kit Siemens MMP to Contactor Size S3 FU Fuse Holder, Midget, Pole, 30A, Open Clip MSP CS MMP Type E Terminal Block Size S3 FU Fuse Block Accessories, Fuse Puller, CC M, 30A MSP CS MMP to Contactor Spacer Size S0 FU Fuse Glass 0 A Fast 250 VAC MSP CS MMP Class 0 Size S2 40 to 50A FU Fuseholder Bussmann Panel Mount MSP CS Link Kit Siemens MMP to Contactor Size S2 FU Label Fuse Selection 250V 0A Glass MSP CS MMP to Contactor Spacer Size S0 FU Fuse, Class CC, Time Delay, 600VAC, 6.0A, 200K AIC MSP CS MMP Class 0 Size S2 40 to 50A FU Fuse Block Accessories, Fuse Cover, CC M, 30A MSP CS Link Kit Siemens MMP to Contactor Size S2 FU Fuse Holder, Class CC, 3 Pole, 30A, Open Clip MSP CS MMP to Contactor Spacer Size S0 FU Fuse, Midget, Time Delay, 500VAC, 5A, 0K AIC MSP CS MMP Class 0 Size S3 43 to 63A FU Fuse Block Accessories, Fuse Puller, CC M, 30A MSP CS Link Kit Siemens MMP to Contactor Size S3 FU Fuse, Class CC, Time Delay, 600VAC, 6.0A, 200K AIC MSP CS MMP Type E Terminal Block Size S3 FU Fuse Block Accessories, Fuse Cover, CC M, 30A MSP CS MMP to Contactor Spacer Size S0 GOI Number: SWBR0 Device ID McQuay Part # Description CB Circuit Breaker 3-Pole 5A 480VAC 22kA CB Circuit Breaker 3-Pole 5A 480VAC 22kA CC Extension I/O Siemens 2 (5 Points)-MT3025 CC Connector Extension I/O Direct Connect FU Fuse Holder, Class CC, 3 Pole, 30A, Open Clip GF Relay GE Ground Fault Panel Mount GF Bracket Connector Single Ground Fault Relay AWS No GND Ground Lug Brumell 2X 4ga - 2/0 GND Label Ground Lug Torque HPR Relay, 20 VAC, 0A, DPDT HPR Relay Socket, DIN Rail, Screw Terminal, 2 Pole HPR Relay, 20 VAC, 0A, DPDT OLF Receptacle Ground Fault Interrupter 5A OLF Label Switch AGZ OLF Bracket AGZ Outlet Cover OLF Label, Danger, Service Outlet PD Power Block, 600V, 420A, 3 Pole, x 8, Line: 600MCM-... PD Power Block, 600V, 75A, 3 Pole, x 6, Line: 2/0-4, Loa... PD Power Block, 600V, 75A, 3 Pole, x 6, Line: 2/0-4, Loa... PS Terminal Flag Right Angle.250x AWG Ins Air-Cooled Scroll Chiller, AGZ , Vintage E, Unit Rev. 00 Rev. C /5 RPL / Page 0

11 Unit Controls Ref. Description Part Qty No. Number CC,2 Circuit Control Module EEXV,2 Extension IO for Electronic Expansion Valve FAN, 2 Exhaust Fan, Control Box (Code 5= H) FAN, 2 Filter Assy, Control Box Exhaust Fan (Code 5= H) GF Relay, Ground Fault (Code 9 = G) * HPR,2 High Pressure Relay, 20 VAC, 0A HTR-8 Heater, Control Box (Code 27= B,L) MPR,2 Motor Protection Relay, 20 VAC, 0A OLF Ground Fault Interrupter Receptacle PD00,200 Fan Distribution Block, 75A PS, PS2 Pumpdown Switch REM Remote Display (Code 8= U) RR Rapid Restore Module (Code 59 = RR) SR, 2 Relay, Liquid Line Solenoid, 0A SR5, 6 Relay, Hot Gas ByPass Solenoid, 0A (Code 29= NH,VH,FH) SR, 2 Relay, Discharge Solenoid, 6A (all sizes) SR2, 22 Relay, Discharge Solenoid, 6A (only on sizes 40-80) SW Main Control Switch UC Unit Controller Battery for Unit Controller * Qty= for units with Single Point Power Connection (Code 2= PC, DC, DH); Qty= 2 for Multi-Point Power Connection (Code 2= MN, WN) Air-Cooled Scroll Chiller, AGZ , Vintage E, Unit Rev. 00 Rev. C /5 RPL / Page

12 Refrigeration Circuit Compressor Layout Diagrams Evaporator Circuit 2 Unit Size Circuit Evaporator Circuit Unit Size Circuit 2 Air-Cooled Scroll Chiller, AGZ , Vintage E, Unit Rev. 00 Rev. C /5 RPL / Page 2

13 Refrigeration Circuit Compressors AGZ 075 The original compressors in the 075E units are Tandem Assemblies. The part numbers listed below are for SINGLE Compressors. When replacing a single Compressor from a Tandem Assembly, the original piping is reused. When the unit has an unequal Tandem Assembly (two Compressors with different HP ratings; Circuit 2 below), confirm the HP of the required Compressor before ordering. Unit Size 075E Ref. Part Part No. Description Number 208/230V 380V 400/460V 575V Compressor- Circuit 20 HP Compressor- Circuit 20 HP Compressor- Circuit 20 HP Compressor- Circuit 20 HP Compressor- Circuit 20 HP Compressor- Circuit 20 HP Compressor- Circuit 20 HP Compressor- Circuit 20 HP Compressor- Circuit 2 5 HP Compressor- Circuit 2 5 HP Compressor- Circuit 2 5 HP Compressor- Circuit 2 5 HP Compressor- Circuit 2 20 HP Compressor- Circuit 2 20 HP Compressor- Circuit 2 20 HP Compressor- Circuit 2 20 HP N/S Crankcase Heater- 90W (for 5 HP) N/S Crankcase Heater- 20W (for 20 HP) N/S= Not shown on diagram For 380V Compressors, contact Daikin Applied with unit model and serial number to identify the correct compressor(s). Air-Cooled Scroll Chiller, AGZ , Vintage E, Unit Rev. 00 Rev. C /5 RPL / Page 3

14 Refrigeration Circuit Compressors AGZ Unit Size 080E 090E 00E Ref. Part Part No. Description Number Compressor- Circuit # 20 HP Compressor- Circuit # 20 HP Compressor- Circuit # 20 HP Compressor- Circuit # 20 HP Compressor- Circuit # 25 HP Compressor- Circuit # 25 HP Compressor- Circuit # 25 HP Compressor- Circuit # 25 HP /230V 380V 400/460V 575V 208/230V 380V 400/460V 575V 208/230V 380V 400/460V 575V 3 Compressor- Circuit # 20 HP Compressor- Circuit # 20 HP Compressor- Circuit # 20 HP Compressor- Circuit # 20 HP Compressor- Circuit # 25 HP Compressor- Circuit # 25 HP Compressor- Circuit # 25 HP Compressor- Circuit # 25 HP Compressor- Circuit #2 20 HP Compressor- Circuit #2 20 HP Compressor- Circuit #2 20 HP Compressor- Circuit #2 20 HP Compressor- Circuit #2 25 HP Compressor- Circuit #2 25 HP Compressor- Circuit #2 25 HP Compressor- Circuit #2 25 HP Compressor- Circuit #2 20 HP Compressor- Circuit #2 20 HP Compressor- Circuit #2 20 HP Compressor- Circuit #2 20 HP Compressor- Circuit #2 25 HP Compressor- Circuit #2 25 HP Compressor- Circuit #2 25 HP Compressor- Circuit #2 25 HP Compressor- Circuit #2 30 HP Compressor- Circuit #2 30 HP Compressor- Circuit #2 30 HP Compressor- Circuit #2 30 HP N/S Crankcase Heater- 20W (for 20, 25 HP) N/S Crankcase Heater- 40W (for 30 HP) N/S= Not shown on diagram For 380V Compressors, contact Daikin Applied with unit model and serial number to identify the correct compressor(s). Air-Cooled Scroll Chiller, AGZ , Vintage E, Unit Rev. 00 Rev. C /5 RPL / Page 4

15 Refrigeration Circuit Compressors AGZ 0-30 Unit Size 0E 20E 30E Ref. Part Part No. Description Number Compressor- Circuit # 30 HP Compressor- Circuit # 30 HP Compressor- Circuit # 30 HP Compressor- Circuit # 30 HP /230V 380V 400/460V 575V 208/230V 380V 400/460V 575V 208/230V 380V 400/460V 575V 3 Compressor- Circuit # 25 HP Compressor- Circuit # 25 HP Compressor- Circuit # 25 HP Compressor- Circuit # 25 HP Compressor- Circuit # 30 HP Compressor- Circuit # 30 HP Compressor- Circuit # 30 HP Compressor- Circuit # 30 HP Compressor- Circuit #2 25 HP Compressor- Circuit #2 25 HP Compressor- Circuit #2 25 HP Compressor- Circuit #2 25 HP Compressor- Circuit #2 30 HP Compressor- Circuit #2 30 HP Compressor- Circuit #2 30 HP Compressor- Circuit #2 30 HP Compressor- Circuit #2 30 HP Compressor- Circuit #2 30 HP Compressor- Circuit #2 30 HP Compressor- Circuit #2 30 HP Compressor- Circuit #2 40 HP Compressor- Circuit #2 40 HP Compressor- Circuit #2 40 HP Compressor- Circuit #2 40 HP N/S Crankcase Heater- 20W (for 25 HP) N/S Crankcase Heater- 40W (for 30, 40 HP) N/S= Not shown on diagram For 380V Compressors, contact Daikin Applied with unit model and serial number to identify the correct compressor(s). Air-Cooled Scroll Chiller, AGZ , Vintage E, Unit Rev. 00 Rev. C /5 RPL / Page 5

16 Refrigeration Circuit Compressors AGZ 40-6 Unit Size 40E 50E 6E Ref. Part Part No. Description Number Compressor- Circuit # 40 HP Compressor- Circuit # 40 HP Compressor- Circuit # 40 HP Compressor- Circuit # 40 HP /230V 380V 400/460V 575V 208/230V 380V 400/460V 575V 208/230V 380V 400/460V 575V 3 Compressor- Circuit # 30 HP Compressor- Circuit # 30 HP Compressor- Circuit # 30 HP Compressor- Circuit # 30 HP Compressor- Circuit # 40 HP Compressor- Circuit # 40 HP Compressor- Circuit # 40 HP Compressor- Circuit # 40 HP Compressor- Circuit #2 30 HP Compressor- Circuit #2 30 HP Compressor- Circuit #2 30 HP Compressor- Circuit #2 30 HP Compressor- Circuit #2 40 HP Compressor- Circuit #2 40 HP Compressor- Circuit #2 40 HP Compressor- Circuit #2 40 HP Compressor- Circuit #2 40 HP Compressor- Circuit #2 40 HP Compressor- Circuit #2 40 HP Compressor- Circuit #2 40 HP N/S Crankcase Heater- 40W (for 30, 40 HP) N/S= Not shown on diagram For 380V Compressors, Contact Daikin Applied with unit model and serial number to identify the correct compressor(s). Air-Cooled Scroll Chiller, AGZ , Vintage E, Unit Rev. 00 Rev. C /5 RPL / Page 6

17 Refrigeration Circuit Compressors AGZ 70, 80 Unit Size 70E 80E Ref. No. Part Description Part Number Compressor- Circuit # 25 HP Compressor- Circuit # 25 HP Compressor- Circuit # 25 HP Compressor- Circuit # 25 HP Compressor- Circuit # 30 HP Compressor- Circuit # 30 HP Compressor- Circuit # 30 HP Compressor- Circuit # 30 HP /230V 380V 400/460V 575V 208/230V 380V 400/460V 575V 3 Compressor- Circuit # 25 HP Compressor- Circuit # 25 HP Compressor- Circuit # 25 HP Compressor- Circuit # 25 HP Compressor- Circuit # 30 HP Compressor- Circuit # 30 HP Compressor- Circuit # 30 HP Compressor- Circuit # 30 HP Compressor- Circuit # 30 HP Compressor- Circuit # 30 HP Compressor- Circuit # 30 HP Compressor- Circuit # 30 HP Compressor- Circuit #2 30 HP Compressor- Circuit #2 30 HP Compressor- Circuit #2 30 HP Compressor- Circuit #2 30 HP Compressor- Circuit #2 30 HP Compressor- Circuit #2 30 HP Compressor- Circuit #2 30 HP Compressor- Circuit #2 30 HP Compressor- Circuit #2 30 HP Compressor- Circuit #2 30 HP Compressor- Circuit #2 30 HP Compressor- Circuit #2 30 HP N/S Crankcase Heater- 20W (for 25 HP) N/S Crankcase Heater- 40W (for 30 HP) N/S= Not shown on diagram For 380V Compressors, Contact Daikin Applied with unit model and serial number to identify the correct compressor(s). Air-Cooled Scroll Chiller, AGZ , Vintage E, Unit Rev. 00 Rev. C /5 RPL / Page 7

18 Refrigeration Circuit Evaporator Plate to Plate Evaporator, Universal Connection (without insulation) Unit Sizes Part Number Unit Sizes Part Number , , Unit Sizes Ref. # Description Part Number N/S Sensor Well N/S Heater, Evaporator, 00W N/S Thermostat, -Stage N/S = Not Shown on diagram Evaporator Ref.# Description Part Number Pipe Assembly Pipe Assembly Clamp- Victaulic, 2.88 OD Clamp- Victaulic, 2.88 OD Flow Sensor with Adapter Adapter only N/S Cable- Flow Sensor (0 Meter) N/S = Not shown on diagram Included in Electronic Water Flow Switch Kit Air-Cooled Scroll Chiller, AGZ , Vintage E, Unit Rev. 00 Rev. C /5 RPL / Page 8

19 Refrigeration Circuit Evaporator Insulation Evaporator Single Double Unit Size Ref.# Description Part Number Insulation Insulation Insulation, Refrigerant Side Insulation, Water Side Insulation, Water Side Insulation, Wrap Insulation, Wrap Insulation, Wrap Insulation, Wrap Insulation, Wrap Insulation, Wrap Insulation, Wrap Insulation, Wrap Insulation, Wrap Insulation, Wrap Insulation, Wrap sq. ft Insulation, Wrap sq. ft Insulation, Wrap sq. ft Insulation, Wrap sq. ft Insulation, Wrap sq. ft Insulation, Wrap sq. ft Insulation, Wrap sq. ft Insulation, Wrap sq. ft Insulation, Wrap sq. ft Insulation, Wrap sq. ft N/S Insulation Tape (sold by the foot) Varies Varies Insulation p/n is sold by the square foot. Air-Cooled. Scroll Chiller, AGZ , Vintage E, Unit Rev. 00 Rev. C /5 RPL / Page 9

20 Refrigeration Circuit Liquid Line Piping Diagram L6 L3 L0 L08 L Unit Size 0-30 shown Circuit # w/o HGBP L06 L53 L52 L5 L03 L04 Air-Cooled Scroll Chiller, AGZ , Vintage E, Unit Rev. 00 Rev. C /5 RPL / Page 20

21 Refrigeration Circuit Liquid Line Piping Components Ref.# Description Part Number Quantity L03 Electronic Expansion Valve (075-00) per circuit L03 Electronic Expansion Valve (0-80) per circuit N/S Cable, Electr Expansion Valve per circuit L04 Sight Glass per circuit L06 Valve- Solenoid,.2 (075-30) per circuit L06 Valve- Solenoid,.2 (40-80) per circuit SV,2 (N/S) Cable, Liquid Line Solenoid, 32 ft per circuit L08 Filter Drier- Shell per circuit L0 Filter Drier- Core per circuit L Felt Gasket Kit per circuit L3 Shut Off Valve, per circuit L6 Valve- Charge.37 x per circuit L5 Valve- Schrader per circuit L52 Valve- Core per circuit L53 Valve- Cap per circuit N/S = Not shown on diagram Air-Cooled Scroll Chiller, AGZ , Vintage E, Unit Rev. 00 Rev. C /5 RPL / Page 2

22 Refrigeration Circuit Discharge Line Piping Diagrams D0 D05 Chicago Code D42 D53 D52 D5 D52 D5 Unit Size 0-30 shown Circuit # w/o HGBP Ref.# Description Part Number Quantity D05 Valve- Discharge Shut-Off, per circuit D0 Valve- Solenoid,.2 (sizes & 40-80) per circuit D0 Valve- Solenoid,.38 (sizes 0-30) per circuit N/S Connector, Discharge Solenoid per circuit D42 Valve- Relief (Chicago Code, Code 46 = B,C,F,V) per circuit D5 Valve- Schrader per circuit * D52 Valve- Core per circuit D53 Valve- Cap per circuit * Quantity = 3 on AGZ075E, circuit 2. N/S = Not Shown on diagram Air-Cooled Scroll Chiller, AGZ , Vintage E, Unit Rev. 00 Rev. C /5 RPL / Page 22

23 Refrigeration Circuit Suction Line Piping Diagrams S2 S50 S53 S52 S5 S02 Unit Size shown Circuit # with optional Suction Valve Quantity Ref.# Description Part Number Circuit Circuit 2 S02 Suction Valve- Ball 2.625, Ckt (Code 30=V, Size 075) S02 Suction Valve- Ball 2.25, Ckt 2 (Code 30=V, Size 075) S02 Suction Valve- Ball (Code 30=V, Sizes ) S2 Fusible Plug.38 NPT S50 Valve- Charge.37 x S5 Valve- Schrader S52 Valve- Core S53 Valve- Cap Air-Cooled Scroll Chiller, AGZ , Vintage E, Unit Rev. 00 Rev. C /5 RPL / Page 23

24 Refrigeration Circuit Hot Gas Bypass Piping Diagrams HG2 HG HG4 HG53 HG52 Unit Size 0-30 Shown Circuit # HG5 Ref.# Description Part Number Units with HGBP (Code 29=NH,VH) Quantity HG Valve, Angle.88 (Unit Sizes ) per circuit HG Valve, Shut off.2 (Unit Sizes 0-80) per circuit HG2 Valve- Solenoid (Unit Sizes ) per circuit HG2 Valve- Solenoid (Unit Sizes 0-80) per circuit SV5,6 (N/S) Cable, HGBP Solenoid per circuit HG4 Valve- HGBP (Unit Sizes ) per circuit HG4 Valve- HGBP (Unit Sizes 0-80) per circuit HG5 Valve- Schrader per circuit HG52 Core- Schrader Valve per circuit HG53 Cap- Schrader Valve per circuit N/S Cable- Sol. & HGBP Valves per circuit N/S= Not shown on diagram Air-Cooled Scroll Chiller, AGZ , Vintage E, Unit Rev. 00 Rev. C /5 RPL / Page 24

25 Refrigeration Circuit Sensor & Transducer Location Diagram HP2 502 S3 S2 HP S S08 Air-Cooled Scroll Chiller, AGZ , Vintage E, Unit Rev. 00 Rev. C /5 RPL / Page 25

26 Refrigeration Circuit Sensor & Transducer Components Ref. Description Part Qty No. Number HP Switch- High Pressure Circuit #, 650 psi (Code 46= A,D,E,W,Z) HP Switch- High Pressure Circuit #, 540 psi (Code 46= B,C,F,V - Chicago) HP2 Switch- High Pressure Circuit #2, 650 psi (Code 46= A,D,E,W,Z) HP2 Switch- High Pressure Circuit #2, 540 psi (Code 46= B,C,F,V - Chicago) S00 Sensor- Leaving Water Temperature, 354" S05* Sensor- Outside Air Temperature, 236" S08 Sensor- Entering Water Temperature, 236" S2 Sensor- Suction Temperature Circuit #, 236" S3 Sensor- Suction Temperature Circuit #2, 236" Transducer- Low Pressure, Circuits & 2 Suction (S0, S02) Transducer- High Pressure, Circuits & 2 Discharge (S03, S04) N/S Cable for Transducers, 6 ft N/S = Not shown on diagram * Not shown on diagram. Mounted below the condenser coil rail. Air-Cooled Scroll Chiller, AGZ , Vintage E, Unit Rev. 00 Rev. C /5 RPL / Page 26

27 Refrigeration Circuit Miscellaneous Components Compressor Sound Enclosures (Code 06= SB) Description Part Number Quantity Sound Enclosure Kit Unit Size One kit per unit Sound Enclosure Kit Unit Size One kit per unit Sound Enclosure Kit Unit Size One kit per unit Sound Enclosure Kit Unit Size One kit per unit Sound Enclosure Kit Unit Size One kit per unit Sound Enclosure Kit Unit Size 30, 208/230V One kit per unit Sound Enclosure Kit Unit Size 30, all other voltages One kit per unit Sound Enclosure Kit Unit Size 40, 208/230V One kit per unit Sound Enclosure Kit Unit Size 40, all other voltages One kit per unit Sound Enclosure Kit Unit Size 50, 208/230V One kit per unit Sound Enclosure Kit Unit Size 50, all other voltages One kit per unit Sound Enclosure Kit Unit Size 6, 208/230V One kit per unit Sound Enclosure Kit Unit Size 6, all other voltages One kit per unit Sound Enclosure Kit Unit Size One kit per unit Sound Enclosure Kit Unit Size One kit per unit Air-Cooled Scroll Chiller, AGZ , Vintage E, Unit Rev. 00 Rev. C /5 RPL / Page 27

28 Condenser Section Fan Motor and Fan Deck Diagram Air-Cooled Scroll Chiller, AGZ , Vintage E, Unit Rev. 00 Rev. C /5 RPL / Page 28

29 Condenser Section Fan Motor and Fan Deck Components & Condenser Coils Fan Motor and Fan Deck Components Ref.# Description Part Number Quantity 90 Motor- 2.0 HP, 208/60/3, 230/60/ per fan 90 Motor- 2.0 HP, 380/60/3, 460/60/ per fan 90 Motor- 2.0 HP, 400/50/ per fan 90 Motor- 2.0 HP, 575/60/ per fan 902 Fan Blade per fan 903 Motor Mounting Bracket (2 per motor) per fan 904 Fan Venturi Panel per fan 950 Grille- Fan per fan Unit Sizes Number of Fans per Unit Condenser Coils Condenser Coil Part Number Microchannel, Standard (Code 8 = M) Microchannel, Electrofin Coated (Code 8 =P) Air-Cooled Scroll Chiller, AGZ , Vintage E, Unit Rev. 00 Rev. C /5 RPL / Page 29

30 Coil Grilles and Coil Louvers Coil Louvers Shown Unit Size W42 W52 Opposite End W40 W5 Control Box End W4 W50 Unit Size Ref.# Description Part Number Coil Grilles W40 Support Post- Side W4 Support Post- Control Box End W42 Support Post- Opposite End W50 Coil Grille- Side W5 Coil Grille- Control Box End W52 Coil Grille- Opposite End N/S Screw x Coil Louvers W40 Support Post- Side W4 Support Post- Control Box End W42 Support Post- Opposite End W50 Coil Louver- Side W5 Coil Louver- Control Box End W52 Coil Louver- Opposite End N/S Screw x N/S = Not shown on diagram Coil Grille Kit (includes all components above) Coil Grille Kit 0-30 (includes all components above) Coil Grille Kit (includes all components above) Coil Louver Kit (includes all components above) Coil Louver Kit 0-30 (includes all components above) Coil Louver Kit (includes all components above) End Louver Kit includes ()W4, ()W42, (2)W5, (2)W52 and (24) screws Air-Cooled Scroll Chiller, AGZ , Vintage E, Unit Rev. 00 Rev. C /5 RPL / Page 30

31 Base Grilles W60 Opposite End Opposite End W60 W62 Control Box End W6 Unit Size W63 Control Box End W62 W6 Unit Size 0-30 W60 Opposite End W6 W64 Control Box End W6 Unit Size Air-Cooled Scroll Chiller, AGZ , Vintage E, Unit Rev. 00 Rev. C /5 RPL / Page 3

32 Base Grilles Unit Size Ref.# Description Part Number W60 Base Grille- Opposite End W6 Base Grille- Side (34.90 x 4.44) W62 Base Grille- Side (34.90 x 39.29) W63 Base Grille- Side (34.90 x 44.74) W64 Base Grille- Side (34.90 x 36.59) N/S Screw-.25 x 20, N/S = Not shown on diagram Base Grille Kit (includes all components above) Base Grille Kit 0-30 (includes all components above) Base Grille Kit (includes all components above) Air-Cooled Scroll Chiller, AGZ , Vintage E, Unit Rev. 00 Rev. C /5 RPL / Page 32

33 Base Louvers Unit Size W70 W63 W62 W62 Control Box End Opposite End W6 W7 W60 Unit Size 0-30 W70 W63 W62 W62 Opposite End W6 Control Box End W7 W60 Unit Size Control Box End W62 W70 W6 W63 W62 W6 W62 Opposite End Air-Cooled Scroll Chiller, AGZ , Vintage E, Unit Rev. 00 W60 Rev. C /5 W63 W70 W62 RPL / Page 33

34 Base Louvers Unit Size Ref.# Description Part Number W60 Base Louver- Opposite End W6 Base Louver- Side (35.90 x 44.67) W62 Base Louver- Side (35.90 x 39.28) W63 Base Louver- Side (35.90 x 39.64) W63 Base Louver- Side (35.90 x 45.52) W63 Base Louver- Side (35.90 x 36.64) W70 Base Louver- Side (35.90 x 44.67) W7 Base Louver- Side (35.90 x 39.64) W7 Base Louver- Side (35.90 x 45.52) N/S Screw-.25 x 20, N/S = Not shown on diagram Base Louver Kit (includes all components above) Base Louver Kit 0-30 (includes all components above) Base Louver Kit (includes all components above) Air-Cooled Scroll Chiller, AGZ , Vintage E, Unit Rev. 00 Rev. C /5 RPL / Page 34

35 Optional Equipment Alarm Bell Kit Description Part Number Qty. Alarm Bell Kit (includes Alarm Bell and Relay) Alarm Bell Relay, SPDT, 30A, 20VA HGBP Kit The HGBP Kit is designed to add the hot gas bypass option when Code 29= FH (Hot Gas Ready). If Code 29= NN or VN (not Hot Gas Ready) must also order T4 Transformer Kit Description Part Number Qty. HGBP Kit (includes components for both circuits) Unit Sizes Unit Sizes Water Flow Indicator Description Part Number Qty. Water Flow Switch- Paddle Type Water Flow Switch Kit- Electronic -includes Sensor, Adapter and Cable Water Flow Sensor with Adapter Adapter Cable- Water Flow Sensor, 0 Meter Evaporator Strainer Kit Description Part Number Qty. Evaporator Strainer Kit Unit Size Unit Size Control Box Exhaust Fans Kit Description Part Number Qty. Control Box Exhaust Fan Kit Control Box Heater Kit Description Part Number Qty. Control Box Heater Kit Air-Cooled Scroll Chiller, AGZ , Vintage E, Unit Rev. 00 Rev. C /5 RPL / Page 35

36 Optional Equipment 5V Outlet Kit Description Part Number Qty. 5V Outlet Kit (Does not include Transformer, select from below) Transformer Kit for 5V Outlet Kit (units without pumps) Description Part Number Qty. Transformer, 2.0KVA, 208V (60 Hz) Transformer, 2.0KVA, 230V (60 Hz) Transformer, 2.0KVA, 380V (60 Hz) Transformer, 2.0KVA, 460V (60 Hz) Transformer, 2.0KVA, 575V (60 Hz) Transformer, 2.0KVA, 380/400/45 (50 Hz) Fan VFD Kit (For converting units without fan VFDs to one fan VFD per circuit. Includes components and wiring for both circuits, requires High Ambient Exhaust Fan Kit) Description Part Number Qty. Unit Sizes , 208V Unit Sizes , 230V Unit Sizes , 380V Unit Sizes , V Unit Sizes , 575V Unit Sizes 0-80, 208V Unit Sizes 0-80, 230V Unit Sizes 0-80, 380V Unit Sizes 0-80, V Unit Sizes 0-80, 575V Line Reactor Kit Description Part Number Qty. Unit Sizes , V Unit Sizes , 380V Unit Sizes , V Unit Sizes , 575V Unit Sizes 0-80, V Unit Sizes 0-80, 380V Unit Sizes 0-80, V Unit Sizes 0-80, 575V Air-Cooled Scroll Chiller, AGZ , Vintage E, Unit Rev. 00 Rev. C /5 RPL / Page 36

37 Optional Equipment Phase Voltage Monitor Kit Description Part Number Qty. Single Point Units, V Single Point Units, 380V, 400V, 460V Single Point Units, 575V Multi Point Units, V Multi Point Units, 380V, 400V, 460V Multi Point Units, 575V Ground Fault Protection Kit Description Part Number Qty. Single Point Units, all voltages Multi Point Units, all voltages Rapid Restore Module Kit Description Part Number Qty. Rapid Restore Module Assembly Remote User Interface Kit, MTIII Display Module Description Part Number Qty. Remote User Interface Communications Module Kit Description Part Number Qty. LonMark ModBus BACnet MSTP BACnet IP D-Net (AWM) - Requires 5V Outlet Pump Package Components Pump Packages are generated per customer specifications. Contact Daikin Applied with the unit GO number and Serial Number including any available vendor information so that the correct part(s) can be identified. Air-Cooled Scroll Chiller, AGZ , Vintage E, Unit Rev. 00 Rev. C /5 RPL / Page 37

38 Critical Daikin Applied OEM Parts Are What Your HVAC Unit Needs! Daikin Trailblazer Air-Cooled Scroll Chiller AGZ Vintage E, Unit Revision 00 Critical Components UNIT SIZE Voltage Part Number Control Unit Controller (UC) ALL ALL Circuit Control Module (CC,2) ALL ALL High Pressure Relay (HPR,2) ALL ALL Motor Protection Relay (MPR,2) ALL ALL Transducer- Low Pressure (S0,02) ALL ALL Transducer- High Pressure (S03,04) ALL ALL Sensor- Temperature, 9 ft. ALL ALL Switch- High Pressure (HP,2) non-chicago Code ALL ALL Switch- High Pressure (HP,2) with Chicago Code ALL ALL Switch- Main Control (SW) ALL ALL Compressor See RPL Expansion Valve Electronic Expansion Valve ALL Electronic Expansion Valve 0-80 ALL Condenser Fan Components Motor, 2.0 HP ALL 208/230/60/ Motor, 2.0 HP ALL 380/460/60/ Motor, 2.0 HP ALL 400/50/ Motor, 2.0 HP ALL 575/60/ Fan Blade, 30" ALL ALL Call Your Local Daikin Applied Parts Distributor For All Your Parts Needs. To Locate A Distributor, Go To or Call PARTS Rev. C /205 CPL Page of

Daikin. Trailblazer Air-Cooled Scroll Chiller. AGZ Vintage E Unit Revision 00. Replacement Parts List No Revision N 02/2018

Daikin. Trailblazer Air-Cooled Scroll Chiller. AGZ Vintage E Unit Revision 00. Replacement Parts List No Revision N 02/2018 Replacement Parts List No. 700050800 Revision N 02/208 Daikin Trailblazer Air-Cooled Scroll Chiller AGZ 075-80 Vintage E Unit Revision 00 To find your Daikin Applied parts distributor, call -800-377-2787

More information

Daikin. TrailBlazer Air-Cooled Scroll Chiller. AGZ Vintage E Unit Revision 00. Replacement Parts List No Revision P 10/2018

Daikin. TrailBlazer Air-Cooled Scroll Chiller. AGZ Vintage E Unit Revision 00. Replacement Parts List No Revision P 10/2018 Replacement Parts List No. 700028500 Revision P 0/208 Daikin TrailBlazer Air-Cooled Scroll Chiller AGZ 030-070 Vintage E Unit Revision 00 To find your Daikin Applied parts distributor, call -800-377-2787

More information

Daikin McQuay. Global Scroll Compressor Air-Cooled Chiller. AGZ Vintage D Unit Revision 00, 0A (Code 55)

Daikin McQuay. Global Scroll Compressor Air-Cooled Chiller. AGZ Vintage D Unit Revision 00, 0A (Code 55) Replacement Parts List No. 70008600 Revision M /207 Daikin McQuay Global Scroll Compressor Air-Cooled Chiller AGZ 025-90 Vintage D Unit Revision 00, 0A (Code 55) To find your Daikin Applied parts distributor,

More information

Daikin. TrailBlazer Air-Cooled Scroll Chiller. AMZ Vintage A. Replacement Parts List No Revision C 01/2018

Daikin. TrailBlazer Air-Cooled Scroll Chiller. AMZ Vintage A. Replacement Parts List No Revision C 01/2018 Replacement Parts List No. 700052900 Revision C 0/208 Daikin TrailBlazer Air-Cooled Scroll Chiller AMZ 00-040 Vintage A To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com

More information

McQuay. Air-Cooled Global Reciprocating Condensing Unit. ACR Vintage A. Last Manufactured: 2003

McQuay. Air-Cooled Global Reciprocating Condensing Unit. ACR Vintage A. Last Manufactured: 2003 Replacement Parts List No. 110504800 Revision G 04/2016 McQuay Air-Cooled Global Reciprocating Condensing Unit ACR 060-120 Vintage A Last Manufactured: 2003 To find your Daikin Applied parts distributor,

More information

McQuay Air Cooled Chiller AWS175A, AWS190A, AWS210A, AWS230A, AWS250A AWS280A, AWS300A, AWS320A, AWS350A, AWS380A, AWS405A PL

McQuay Air Cooled Chiller AWS175A, AWS190A, AWS210A, AWS230A, AWS250A AWS280A, AWS300A, AWS320A, AWS350A, AWS380A, AWS405A PL McQuay Air Cooled Chiller AWS175A, AWS190A, AWS210A, AWS230A, AWS250A AWS280A, AWS300A, AWS320A, AWS350A, AWS380A, AWS405A PL-1007-3 AWS175A / AWS190A / AWS210A / AWS230A / AWS250A / AWS280A / AWS300A

More information

McQuay Air-Cooled Reciprocating Chiller ALR

McQuay Air-Cooled Reciprocating Chiller ALR Replacement Parts List No. 057115200 Revision S 07/2015 McQuay Air-Cooled Reciprocating Chiller ALR Sizes 010-185 Vintage D Last Manufactured: 2000 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay Air Cooled Chiller AWS280A, AWS300A, AWS320A, AWS350A PL

McQuay Air Cooled Chiller AWS280A, AWS300A, AWS320A, AWS350A PL McQuay Air Cooled Chiller 280A, 300A, 320A, 350A PL-1008-7 280A / 300A / 320A / 350A 1 280A / 300A / 320A / 350A 2 280A / 300A / 320A / 350A 3 280A / 300A / 320A / 350A 4 280A / 300A / 320A / 350A 5 280A

More information

McQuay. Evaporative Condenser Cooled Chiller. EGR Vintage A. Last Manufactured: Replacement Parts List No Revision B 07/2010

McQuay. Evaporative Condenser Cooled Chiller. EGR Vintage A. Last Manufactured: Replacement Parts List No Revision B 07/2010 Replacement Parts List No. 700015100 Revision B 07/2010 McQuay Evaporative Condenser Cooled Chiller EGR 060-240 Vintage A Last Manufactured: 2004 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Air Cooled Screw Chiller. ALS Vintage B. Last Manufactured: Replacement Parts List No Revision C 06/2017

McQuay. Air Cooled Screw Chiller. ALS Vintage B. Last Manufactured: Replacement Parts List No Revision C 06/2017 Replacement Parts List No. 700027300 Revision C 06/2017 cquay Air Cooled Screw Chiller ALS 300-425 Vintage B Last anufactured: 2001 To find your Daikin Applied parts distributor, call 1-800-377-2787 or

More information

Daikin. Magnitude TM Magnetic Bearing Centrifugal Chiller. WME 0501S, 0502S, 0701S, 0702S Vintage B

Daikin. Magnitude TM Magnetic Bearing Centrifugal Chiller. WME 0501S, 0502S, 0701S, 0702S Vintage B Replacement Parts List No. 0700053000 Revision C 02/2018 Daikin Magnitude TM Magnetic Bearing Centrifugal Chiller WME 0501S, 0502S, 0701S, 0702S Vintage B To find your Daikin Applied parts distributor,

More information

Daikin McQuay. Roofpak Condensing Unit Medium Cabinet, Standalone Standard & Digital Compressor Models

Daikin McQuay. Roofpak Condensing Unit Medium Cabinet, Standalone Standard & Digital Compressor Models Replacement Parts List No. 7000600 Revision S 0/08 Daikin McQuay Roofpak Condensing Unit Medium Cabinet, Standalone Standard & Digital Compressor Models RCS 045-075 Tons Vintage D Code = A, A, YA Unit

More information

McQuay. Magnitude Water-Cooled Magnetic Bearing Centrifugal Chiller. WMC 150 Vintage A. Last Manufactured: 2005

McQuay. Magnitude Water-Cooled Magnetic Bearing Centrifugal Chiller. WMC 150 Vintage A. Last Manufactured: 2005 Replacement Parts List No. 700005500 Revision J 10/2017 McQuay Magnitude Water-Cooled Magnetic Bearing Centrifugal Chiller WMC 150 Vintage A Last Manufactured: 2005 To find your Daikin Applied parts distributor,

More information

McQuay. Water-Cooled Screw Chiller. PFS Vintage B. Last Manufactured: Replacement Parts List No Revision D 02/2017

McQuay. Water-Cooled Screw Chiller. PFS Vintage B. Last Manufactured: Replacement Parts List No Revision D 02/2017 Replacement Parts List No. 057118200 Revision D 02/2017 McQuay Water-Cooled Screw Chiller PFS 150-215 Vintage B Last Manufactured: 1997 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 030, 036, 042 Design 1. Replacement Parts List No Revision B 10/2016

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 030, 036, 042 Design 1. Replacement Parts List No Revision B 10/2016 Replacement Parts List No. 700011300 Revision B 10/2016 McQuay Ceiling Mounted Water Source Heat Pump WCRH, WCRW 030, 036, 042 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. HiLine Fan Coil. HSB Vintage B. Last Manufactured: Replacement Parts List No Revision C 09/2016

McQuay. HiLine Fan Coil. HSB Vintage B. Last Manufactured: Replacement Parts List No Revision C 09/2016 Replacement Parts List No. 055211200 Revision C 09/2016 McQuay HiLine Fan Coil HSB 030-120 Vintage B Last Manufactured: 1990 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit

More information

McQuay. Magnitude Magnetic Bearing Centrifugal Chiller WMC 035T. Last Manufactured: Replacement Parts List No Revision J 12/2017

McQuay. Magnitude Magnetic Bearing Centrifugal Chiller WMC 035T. Last Manufactured: Replacement Parts List No Revision J 12/2017 Replacement Parts List No. 700005800 Revision J 12/2017 McQuay Magnitude Magnetic Bearing Centrifugal Chiller WMC 035T Last Manufactured: 2008 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 048, 060, 070 Design 1. Replacement Parts List No Revision C 10/2016

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 048, 060, 070 Design 1. Replacement Parts List No Revision C 10/2016 Replacement Parts List No. 700011400 Revision C 10/2016 McQuay Ceiling Mounted Water Source Heat Pump WCRH, WCRW 048, 060, 070 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay Climate Control. Horizontal Water Source Heat Pump. CC, CG, CW Vintage C, D. Last Manufactured: 1986

McQuay Climate Control. Horizontal Water Source Heat Pump. CC, CG, CW Vintage C, D. Last Manufactured: 1986 Replacement Parts List No. 05520400 Revision D 01/2017 McQuay Climate Control Horizontal Water Source Heat Pump CC, CG, CW 0750-1000 Vintage C, D Last Manufactured: 1986 To find your Daikin Applied parts

More information

McQuay. Air Cooled Screw Chiller. ALS Vintage B. Last Manufactured: Replacement Parts List No Revision B 05/2016

McQuay. Air Cooled Screw Chiller. ALS Vintage B. Last Manufactured: Replacement Parts List No Revision B 05/2016 Replacement Parts List No. 700027200 Revision B 05/2016 cquay Air Cooled Screw Chiller ALS 220-280 Vintage B Last anufactured: 2001 To find your Daikin Applied parts distributor, call 1-800-377-2787 or

More information

McQuay. Global Air-Cooled Screw Compressor Chiller. AGS (60 Hertz) (50 Hertz) Vintage B. Last Manufactured: 2008

McQuay. Global Air-Cooled Screw Compressor Chiller. AGS (60 Hertz) (50 Hertz) Vintage B. Last Manufactured: 2008 Replacement Parts List No. 700007900 Revision H 12/2017 McQuay Global Air-Cooled Screw Compressor Chiller AGS 230-475 (60 Hertz) 206-411 (50 Hertz) Vintage B Last Manufactured: 2008 To find your Daikin

More information

McQuay. Seasonpak Reciprocating Chiller. WHR Vintage C. Last Manufactured: Replacement Parts List No Revision I 05/2016

McQuay. Seasonpak Reciprocating Chiller. WHR Vintage C. Last Manufactured: Replacement Parts List No Revision I 05/2016 Replacement Parts List No. 055224300 Revision I 05/2016 McQuay Seasonpak Reciprocating Chiller WHR 008-120 Vintage C Last Manufactured: 1998 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. Roofpak Condensing Unit Small Cabinet, Standalone Standard & Digital Compressor Models

Daikin McQuay. Roofpak Condensing Unit Small Cabinet, Standalone Standard & Digital Compressor Models Replacement Parts List No. 70009700 Revision M 0/08 Daikin McQuay Roofpak Condensing Unit Small Cabinet, Standalone Standard & Digital Compressor Models RCS 05-040 Vintage D Code = A, A, YA Code 44= R,

More information

McQuay Climate Control. Commercial Unitary Rooftop. CUR Vintage F. Last Manufactured: 1996

McQuay Climate Control. Commercial Unitary Rooftop. CUR Vintage F. Last Manufactured: 1996 Replacement s List No. 055236800 Revision C 11/2016 McQuay Climate Control Commercial Unitary Rooftop CUR 075-150 Vintage F Last Manufactured: 1996 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Two-Stage Centrifugal Chiller WTC 700. Replacement Parts List No Revision B 07/2017

McQuay. Two-Stage Centrifugal Chiller WTC 700. Replacement Parts List No Revision B 07/2017 Replacement Parts List No. 700014000 Revision B 07/2017 McQuay Two-Stage Centrifugal Chiller WTC 700 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.daikinapplied.com Table

More information

McQuay. Two-Stage Centrifugal Chiller WTC 500. Replacement Parts List No Revision A 10/2011

McQuay. Two-Stage Centrifugal Chiller WTC 500. Replacement Parts List No Revision A 10/2011 Replacement Parts List No. 700019800 Revision A 10/2011 McQuay Two-Stage Centrifugal Chiller WTC 500 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.daikinapplied.com Table

More information

McQuay. Reciprocating Condensing Unit. ALP Vintage C. Last Manufactured: Replacement Parts List No Revision W 10/2017

McQuay. Reciprocating Condensing Unit. ALP Vintage C. Last Manufactured: Replacement Parts List No Revision W 10/2017 Replacement Parts List No. 700015000 Revision W 10/2017 McQuay Reciprocating Condensing Unit ALP 013-230 Vintage C Last Manufactured: 2002 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Global Air-Cooled Scroll Chiller. AGZ Vintage A Two-circuit. Last Manufactured: 2005

McQuay. Global Air-Cooled Scroll Chiller. AGZ Vintage A Two-circuit. Last Manufactured: 2005 Replacement Parts List No. 057117900 Revision R 10/2016 McQuay Global Air-Cooled Scroll Chiller AGZ 030-065 Vintage A Two-circuit Last Manufactured: 2005 To find your Daikin Applied parts distributor,

More information

McQuay. Incremental. PFEC, PFES, PFHC, PFHS Suite II, 2 Motor 007, 009, 012, 015 Designs A(1), B(2) Last Manufactured: 2001

McQuay. Incremental. PFEC, PFES, PFHC, PFHS Suite II, 2 Motor 007, 009, 012, 015 Designs A(1), B(2) Last Manufactured: 2001 Replacement Parts List 110505300 Revision G 07/2016 McQuay Incremental PFEC, PFES, PFHC, PFHS Suite II, 2 Motor 007, 009, 012, 015 Designs A(1), B(2) Last Manufactured: 2001 To find your Daikin Applied

More information

McQuay Climate Control. Water Source Heat Pump. CC, CG Vintage E, F, G. Last Manufactured: 1986

McQuay Climate Control. Water Source Heat Pump. CC, CG Vintage E, F, G. Last Manufactured: 1986 Replacement Parts List No. 110508600 Revision C 12/2008 McQuay Climate Control Water Source Heat Pump CC, CG 750-1000 Vintage E, F, G Last Manufactured: 1986 To find your Daikin Applied parts distributor,

More information

McQuay Climate Control Singer

McQuay Climate Control Singer Replacement Parts List No. 55205400 Rev. B 09/2015 McQuay Climate Control Singer Large Vertical Water Source Heat Pump LGP, LHP, LWP 18, 22 Vintage A Last Manufactured: 1989 To find your Daikin Applied

More information

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 007, 009, 012 Design 4. Replacement Parts List No Revision L 02/2018

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 007, 009, 012 Design 4. Replacement Parts List No Revision L 02/2018 Replacement Parts List No. 700016100 Revision L 02/2018 Daikin McQuay Enfinity Horizontal Water Source Heat Pump WCCH, WCCW 007, 009, 012 Design 4 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Centrifugal Chiller WPV 320A - 350A. Last Manufactured: Replacement Parts List No Revision E 12/2017

McQuay. Centrifugal Chiller WPV 320A - 350A. Last Manufactured: Replacement Parts List No Revision E 12/2017 Replacement Parts List No. 700005300 Revision E 12/2017 McQuay Centrifugal Chiller WPV 320A - 350A Last Manufactured: 2008 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.daikinapplied.com

More information

Daikin. Magnitude Magnetic Bearing Compressor Centrifugal Chiller. WMC 400D Vintage C. Replacement Parts List No Revision B 10/2015

Daikin. Magnitude Magnetic Bearing Compressor Centrifugal Chiller. WMC 400D Vintage C. Replacement Parts List No Revision B 10/2015 Replacement Parts List No. 700029500 Revision B 10/2015 Daikin Magnitude Magnetic Bearing Compressor Centrifugal Chiller WMC 400D Vintage C To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Centrifugal Chiller. PF/PFH Size: 063. Replacement Parts List No Revision V 05/2012

Centrifugal Chiller. PF/PFH Size: 063. Replacement Parts List No Revision V 05/2012 Replacement Parts List No. 057113900 Revision V 05/2012 Centrifugal Chiller PF/PFH Size: 063 To find your Daikin McQuay parts distributor, call 1-800-377-2787 or visit www.daikinmcquay.com Contents Parts

More information

McQuay. Thinline Vertical Fan Coil Floor Mounted. TSF Vintage G. Last Manufactured: 1997

McQuay. Thinline Vertical Fan Coil Floor Mounted. TSF Vintage G. Last Manufactured: 1997 Replacement Parts List No. 057117400 Revision F 08/2016 McQuay Thinline Vertical Fan Coil Floor Mounted TSF 021-121 Vintage G Last Manufactured: 1997 To find your Daikin Applied parts distributor, call

More information

Daikin. Magnitude Magnetic Bearing Compressor Centrifugal Chiller. WMC 043S, 048S, 060S 036D, 043D, 048D, 060D Vintage D

Daikin. Magnitude Magnetic Bearing Compressor Centrifugal Chiller. WMC 043S, 048S, 060S 036D, 043D, 048D, 060D Vintage D Replacement Parts List No. 700052800 Revision C 02/2018 Daikin Magnitude Magnetic Bearing Compressor Centrifugal Chiller WMC 043S, 048S, 060S 036D, 043D, 048D, 060D Vintage D To find your Daikin Applied

More information

Daikin. Magnitude Magnetic Bearing Compressor Centrifugal Chiller. WMC 125S, 145S, 200S 145D, 150D, 225D, 250D, 275D, 290D Vintage C

Daikin. Magnitude Magnetic Bearing Compressor Centrifugal Chiller. WMC 125S, 145S, 200S 145D, 150D, 225D, 250D, 275D, 290D Vintage C Replacement Parts List No. 700029400 Revision F 10/2017 Daikin Magnitude Magnetic Bearing Compressor Centrifugal Chiller WMC 125S, 145S, 200S 145D, 150D, 225D, 250D, 275D, 290D Vintage C To find your Daikin

More information

McQuay. Seasonmaker Horizontal Fan Coil. TSC Vintage G. Last Manufactured: Replacement Parts List No Revision C 08/2016

McQuay. Seasonmaker Horizontal Fan Coil. TSC Vintage G. Last Manufactured: Replacement Parts List No Revision C 08/2016 Replacement Parts List 057117500 Revision C 08/2016 McQuay Seasonmaker Horizontal Fan Coil TSC 021-121 Vintage G Last Manufactured: 1997 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. Air- Cooled Condenser. ACH, ACX, ACL Vintage A. Replacement Parts List No Revision C 10/2016

Daikin McQuay. Air- Cooled Condenser. ACH, ACX, ACL Vintage A. Replacement Parts List No Revision C 10/2016 Replacement Parts List No. 700023300 Revision C 0/206 Daikin McQuay Air- Cooled Condenser ACH, ACX, ACL 04-225 Vintage A To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com

More information

McQuay. Magnitude Magnetic Bearing Centrifugal Chiller. WMC 400DSC Vintage A. Replacement Parts List No Revision F 10/2017

McQuay. Magnitude Magnetic Bearing Centrifugal Chiller. WMC 400DSC Vintage A. Replacement Parts List No Revision F 10/2017 Replacement Parts List No. 700014700 Revision F 10/2017 McQuay Magnitude Magnetic Bearing Centrifugal Chiller WMC 400DSC Vintage A To find your Daikin Applied parts distributor, call 1-800-377-2787 or

More information

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 042, 048, 060, 070 Design 5

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 042, 048, 060, 070 Design 5 Replacement Parts List No. 700027900 Revision M 09/2018 Daikin McQuay Enfinity Horizontal Water Source Heat Pump WCCH, WCCW 042, 048, 060, 070 Design 5 To find your Daikin Applied parts distributor, call

More information

McQuay. Enfinity Horizontal Water Source Heat Pump. WCRH, WCRW 007, 009, 012 Design 1. Replacement Parts List No Revision B 02/2018

McQuay. Enfinity Horizontal Water Source Heat Pump. WCRH, WCRW 007, 009, 012 Design 1. Replacement Parts List No Revision B 02/2018 Replacement Parts List No. 700011100 Revision B 02/2018 McQuay Enfinity Horizontal Water Source Heat Pump WCRH, WCRW 007, 009, 012 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW Design 2. Replacement Parts List No Revision F 04/2018

Daikin. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW Design 2. Replacement Parts List No Revision F 04/2018 Replacement Parts List No. 700050900 Revision F 04/2018 Daikin Enfinity Horizontal Water Source Heat Pump WCCH, WCCW 072-120 Design 2 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. Incremental. Suite II, 2 Motor PDES Design C (3) Last Manufactured: 2008

Daikin McQuay. Incremental. Suite II, 2 Motor PDES Design C (3) Last Manufactured: 2008 Replacement Parts List 700018500 Revision B 02/2012 Daikin McQuay Incremental Suite II, 2 Motor PDES 009-015 Design C (3) Last Manufactured: 2008 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin. Magnitude Magnetic Bearing Compressor Centrifugal Chiller. WMC 350D, 400D Vintage C. Replacement Parts List No Revision F 10/2017

Daikin. Magnitude Magnetic Bearing Compressor Centrifugal Chiller. WMC 350D, 400D Vintage C. Replacement Parts List No Revision F 10/2017 Replacement Parts List No. 700029500 Revision F 10/2017 Daikin Magnitude Magnetic Bearing Compressor Centrifugal Chiller WMC 350D, 400D Vintage C To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Water Source Heat Pump Replacement Chassis. VF Vintage H. Last Manufactured: 1992

McQuay. Water Source Heat Pump Replacement Chassis. VF Vintage H. Last Manufactured: 1992 Replacement Parts List No. 110502800 Revision A 02/2006 McQuay Water Source Heat Pump Replacement Chassis VF 100-330 Vintage H Last Manufactured: 1992 To find your Daikin Applied parts distributor, call

More information

McQuay Climate Control Singer. Rooftop Unit. ER, R 080 Vintage A, B, C, D. Last Manufactured: 1996

McQuay Climate Control Singer. Rooftop Unit. ER, R 080 Vintage A, B, C, D. Last Manufactured: 1996 Replacement Parts List No. 779200300 Revision C 04/2011 McQuay Climate Control Singer Rooftop Unit ER, R 080 Vintage A, B, C, D Last Manufactured: 1996 To find your Daikin Applied parts distributor, call

More information

Daikin McQuay. Enfinity Vertical Water Source Heat Pump. WVFC, WVFW Design 1. Replacement Parts List No Revision S 01/2018

Daikin McQuay. Enfinity Vertical Water Source Heat Pump. WVFC, WVFW Design 1. Replacement Parts List No Revision S 01/2018 Replacement Parts List No. 700012100 Revision S 01/2018 Daikin McQuay Enfinity Vertical Water Source Heat Pump WVFC, WVFW 009-070 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin Daikin McQuay McQuay

Daikin Daikin McQuay McQuay Replacement Parts List No. 0700022800 Revision W /207 Daikin Daikin McQuay McQuay Magnitude TM Magnetic Bearing Centrifugal Chiller WME 0700 To find your Daikin Applied parts distributor, call -800-377-2787

More information

McQuay. Enfinity Ceiling Mounted Water Source Heat Pump. WCCH, WCCW 019, 024 Design 1. Last Manufactured: 2008

McQuay. Enfinity Ceiling Mounted Water Source Heat Pump. WCCH, WCCW 019, 024 Design 1. Last Manufactured: 2008 Replacement Parts List No. 700013300 Revision A 05/2017 McQuay Enfinity Ceiling Mounted Water Source Heat Pump WCCH, WCCW 019, 024 Design 1 Last Manufactured: 2008 To find your Daikin Applied parts distributor,

More information

McQuay Climate Control Singer. Rooftop Unit. ER, R 250 Vintage C, D. Last Manufactured: Replacement Parts List No Revision C 04/2002

McQuay Climate Control Singer. Rooftop Unit. ER, R 250 Vintage C, D. Last Manufactured: Replacement Parts List No Revision C 04/2002 Replacement Parts List No. 779200800 Revision C 04/2002 McQuay Climate Control Singer Rooftop Unit ER, R 250 Vintage C, D Last Manufactured: 1996 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin. PreciseLine Horizontal Large Capacity Blower Coil. BCHD Design 1. Replacement Parts List No Revision A 03/2019

Daikin. PreciseLine Horizontal Large Capacity Blower Coil. BCHD Design 1. Replacement Parts List No Revision A 03/2019 Replacement Parts List No. 700053700 Revision A 03/2019 Daikin PreciseLine Horizontal Large Capacity Blower Coil BCHD 030-050 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Centrifugal Chiller PE046, PE047, PE048, PE050 PEH PF083, PF096, PF105, PF116 PH PHH PL

Centrifugal Chiller PE046, PE047, PE048, PE050 PEH PF083, PF096, PF105, PF116 PH PHH PL Centrifugal Chiller PE046, PE047, PE048, PE050 PEH046-050 PF083, PF096, PF105, PF116 PH046-050 PHH046-050 PL-906-49 Unit ASSY. - Labels / 1987 to Present Unit ASSY. - Labels / 1987 to Present No. Index

More information

McQuay. Ceiling Concealed Water Source Heat Pump. CCH, CCG, CCW 015, 019 Vintage A. Last Manufactured: 1995

McQuay. Ceiling Concealed Water Source Heat Pump. CCH, CCG, CCW 015, 019 Vintage A. Last Manufactured: 1995 Replacement Parts List No. 55235700 Revision C 08/2017 McQuay Ceiling Concealed Water Source Heat Pump CCH, CCG, CCW 015, 019 Vintage A Last Manufactured: 1995 To find your Daikin Applied parts distributor,

More information

TON KW 60HZ

TON KW 60HZ AIR-COOLED CONDENSING UNIT HERMETIC SCROLL RENEWAL PARTS Supersedes: 50.73-RP (009) Form 50.73-RP (4) MODELS YLUA0078, 0088, 0098, 008, 030, 048 YLUA058 STYLES "A & B" 200-3-60 230-3-60 35-3-60 460-3-60

More information

McQuay. Console Water Source Heat Pump. European Unit WWME, WWMJ, WWMK, WWML Designs A, B (1, 2) Last Manufactured: 2004

McQuay. Console Water Source Heat Pump. European Unit WWME, WWMJ, WWMK, WWML Designs A, B (1, 2) Last Manufactured: 2004 Replacement Parts List 110502500 Revision C 02/2017 McQuay Console Water Source Heat Pump European Unit WWME, WWMJ, WWMK, WWML 007-015 Designs A, B (1, 2) Last Manufactured: 2004 To find your Daikin Applied

More information

McQuay. Thermal Systems Absorption Chiller ME, MF Vintage A. Last Manufactured: Replacement Parts List No New 05/2001

McQuay. Thermal Systems Absorption Chiller ME, MF Vintage A. Last Manufactured: Replacement Parts List No New 05/2001 Replacement Parts List No. 1105050 New 05/2001 McQuay Thermal Systems Absorption Chiller ME, MF 21-33 Vintage A Last Manufactured: 1997 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin. SmartSource Compact Vertical Water Source Heat Pump. WGCV 048, 060, 070 Design 1. Replacement Parts List No Revision D 01/2018

Daikin. SmartSource Compact Vertical Water Source Heat Pump. WGCV 048, 060, 070 Design 1. Replacement Parts List No Revision D 01/2018 Replacement Parts List No. 700052400 Revision D 01/2018 Daikin SmartSource Compact Vertical Water Source Heat Pump WGCV 048, 060, 070 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay Westinghouse. Centrifugal Chiller PF, PFH 063. Last Manufactured: Replacement Parts List No Revision AB 06/2018

McQuay Westinghouse. Centrifugal Chiller PF, PFH 063. Last Manufactured: Replacement Parts List No Revision AB 06/2018 Replacement Parts List No. 57113900 Revision AB 06/2018 McQuay Westinghouse Centrifugal Chiller PF, PFH 063 Last Manufactured: 2002 To find your Daikin Applied parts distributor, call 1-800-377-2787 or

More information

Westinghouse. Rooftop Heating and Cooling. IK 180 Vintage 0, 1, 2, 3, 4. Last Manufactured: 1975

Westinghouse. Rooftop Heating and Cooling. IK 180 Vintage 0, 1, 2, 3, 4. Last Manufactured: 1975 Replacement Parts List No. 055227700 Revision A 03/2003 Westinghouse Rooftop Heating and Cooling IK 180 Vintage 0, 1, 2, 3, 4 Last Manufactured: 1975 To find your Daikin Applied parts distributor, call

More information

Westinghouse. Rooftop Heating and Cooling. IK 300 Vintage 0, 1, 2, 3, 4, 5. Last Manufactured: 1975

Westinghouse. Rooftop Heating and Cooling. IK 300 Vintage 0, 1, 2, 3, 4, 5. Last Manufactured: 1975 Replacement Parts List No. 055227900 Revision A 03/2003 Westinghouse Rooftop Heating and Cooling IK 300 Vintage 0,, 2, 3, 4, 5 Last Manufactured: 975 To find your Daikin Applied parts distributor, call

More information

Daikin McQuay. EnerSaver Packaged Terminal Air Conditioner/Heat Pump. PNES; PNHS Design C (3)

Daikin McQuay. EnerSaver Packaged Terminal Air Conditioner/Heat Pump. PNES; PNHS Design C (3) Replacement Parts List No. 700018700 Revision E 04/2015 Daikin McQuay EnerSaver Packaged Terminal Air Conditioner/Heat Pump PNES; PNHS 009-015 Design C (3) To find your Daikin Applied parts distributor,

More information

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW Design 1. Replacement Parts List No Revision I 12/2015

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW Design 1. Replacement Parts List No Revision I 12/2015 Replacement Parts List No. 700014800 Revision I 12/2015 Daikin McQuay Vertical Stack Water Source Heat Pump WVHC, WVHF, WVHW 009-036 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

SCROLL - AIR COOLED PACKAGED & SPLIT SYSTEM ICE CHILLERS

SCROLL - AIR COOLED PACKAGED & SPLIT SYSTEM ICE CHILLERS SCROLL - AIR COOLED PACKAGED & SPLIT SYSTEM ICE CHILLERS 1 to 40 Nominal Tons Rev-01 TABLE OF CONTENTS Page: Description 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Product Nomenclature Air Cooled Chiller

More information

Daikin Daikin McQuay. Magnitude Water-Cooled Magnetic Bearing Chiller. WMC 400 Vintage B. Replacement Parts List No Revision J 10/2017

Daikin Daikin McQuay. Magnitude Water-Cooled Magnetic Bearing Chiller. WMC 400 Vintage B. Replacement Parts List No Revision J 10/2017 Replacement Parts List No. 700018900 Revision J 10/2017 Daikin Daikin McQuay Magnitude Water-Cooled Magnetic Bearing Chiller WMC 400 Vintage B To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Centrifugal Chiller Single Compressor WSC048, WSC050 TSC048, TSC050 HSC048, HSC050 PL

Centrifugal Chiller Single Compressor WSC048, WSC050 TSC048, TSC050 HSC048, HSC050 PL Centrifugal Chiller Single Compressor WSC048, WSC050 TSC048, TSC050 HSC048, HSC050 PL-906-47 Nomenclature Nomenclature END VIEW- MICROTECH 200 UNITS 6003231 UNIT DATAPLATE 070191901 UNITS WITH FACTORY

More information

Centrifugal Chiller Single Compressor WSC087, TSC087, HSC087 PL

Centrifugal Chiller Single Compressor WSC087, TSC087, HSC087 PL Centrifugal Chiller Single Compressor WSC087, TSC087, HSC087 PL-906-43 Nomenclature Nomenclature No. Index Parts No. Parts Name Drwg. No. Parts Model & Specifi cation Q ty/unit Wiring Symbol Notes END

More information

MODELS YCRL0064, 0074, 0084, 0096, 0118, 0126, 0156, 0177, 0198, 0200, 0230, 0260, 0300, 0345, 0385, 0445, 0530 and YCRL0610 STYLE "A"

MODELS YCRL0064, 0074, 0084, 0096, 0118, 0126, 0156, 0177, 0198, 0200, 0230, 0260, 0300, 0345, 0385, 0445, 0530 and YCRL0610 STYLE A WATER-COOLED LIQUID CHILLERS HERMETIC SCROLL RENEWAL PARTS Supercedes: 150.7-RP1 (709) Form: 150.7-RP1 (810) MODELS YCRL0064, 0074, 0084, 0096, 0118, 016, 0156, 0177, 0198, 000, 030, 060, 0300, 0345, 0385,

More information

McQuay Central Station Air Handler Medium Pressure MSL

McQuay Central Station Air Handler Medium Pressure MSL Replacement Parts List No. 55223700 Revision B 09/2016 McQuay Central Station Air Handler Medium Pressure MSL 190 Vintage C Last Manufactured: 1998 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. Enfinity Vertical Water Source Heat Pump. WVFC, WVFW Design 1. Replacement Parts List No Revision V 11/2018

Daikin McQuay. Enfinity Vertical Water Source Heat Pump. WVFC, WVFW Design 1. Replacement Parts List No Revision V 11/2018 Replacement Parts List No. 700012100 Revision V 11/2018 Daikin McQuay Enfinity Vertical Water Source Heat Pump WVFC, WVFW 009-070 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

C1448, C1848, C2148 Service Parts

C1448, C1848, C2148 Service Parts C8, C88, C8 Service Parts This part list contains the service parts for the air cooled, water cooled and remote air cooled C8, C88, C8 ice machines. To avoid costly and time consuming errors, double check

More information

McQuay. Water Source Heat Pump. HPH, HPV Vintage A, B. Last Manufactured: Replacement Parts List No Revision B 05/2012

McQuay. Water Source Heat Pump. HPH, HPV Vintage A, B. Last Manufactured: Replacement Parts List No Revision B 05/2012 Replacement Parts List No. 055211500 Revision B 05/2012 McQuay Water Source Heat Pump HPH, HPV 009-059 Vintage A, B Last Manufactured: 1986 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1 Replacement Parts List No. 700024700 Revision M 11/2017 Daikin Daikin McQuay SmartSource Single Stage Horizontal Water Source Heat Pump WGSH 007, 009, 012 Design 1 To find your Daikin Applied parts distributor,

More information

MODELS YCAV0157, 0177, 0187, 0197, 0207, 0227, 0247 AND YCAV0267 STYLE "A"

MODELS YCAV0157, 0177, 0187, 0197, 0207, 0227, 0247 AND YCAV0267 STYLE A AIR-COOLED SCREW LIQUID CHILLERS RENEWAL PARTS Supersedes: 201.21-RP1 (616) Form 201.21-RP1 (918) MODELS YCAV0157, 0177, 0187, 0197, 0207, 0227, 0247 AND YCAV0267 STYLE "A" 200-3-60 230-3-60 315-3-60 460-3-60

More information

Daikin Daikin McQuay. SmartSource Single Stage Vertical Water Source Heat Pump. WGSV 007, 009, 012 Design 1

Daikin Daikin McQuay. SmartSource Single Stage Vertical Water Source Heat Pump. WGSV 007, 009, 012 Design 1 Replacement Parts List No. 700029600 Revision L 11/2017 Daikin Daikin McQuay SmartSource Single Stage Vertical Water Source Heat Pump WGSV 007, 009, 012 Design 1 To find your Daikin Applied parts distributor,

More information

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1 Replacement Parts List No. 700024700 Revision O 10/2018 Daikin Daikin McQuay SmartSource Single Stage Horizontal Water Source Heat Pump WGSH 007, 009, 012 Design 1 To find your Daikin Applied parts distributor,

More information

Prodigy Eclipse ECC, EH330 and EH430 C or D Service Parts

Prodigy Eclipse ECC, EH330 and EH430 C or D Service Parts This part list contains the service parts for the Eclipse 00, 00, and 800 systems. D series models began early 0 The models that are covered include: EH0 C & D EH0 C & D ECC00 ECC00 ECC800 Contents Head

More information

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW 036 Design 2. Replacement Parts List No Revision A 12/2015

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW 036 Design 2. Replacement Parts List No Revision A 12/2015 Replacement Parts List No. 700050700 Revision A 12/2015 Daikin McQuay Vertical Stack Water Source Heat Pump WVHC, WVHF, WVHW 036 Design 2 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Seasonmaker Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage A. Last Manufactured: 1986

McQuay. Seasonmaker Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage A. Last Manufactured: 1986 Replacement Parts List No. 47650300 Rev. A 09/205 McQuay Seasonmaker Large Capacity Fan Coil Direct Drive SCD, SHD 06-20 Vintage A Last Manufactured: 986 To find your Daikin Applied parts distributor,

More information

Pathfinder Remote Evaporators

Pathfinder Remote Evaporators Installation Manual IM 1203 Pathfinder Remote Evaporators Group: Chillers Part Number: IM1203 Date: September, 2014 For Use With Model AWS-C Air-Cooled Chillers 170 to 550 tons 600 to 1930 kw R-134a 60Hz

More information

Daikin McQuay. Centrifugal Chiller WCC 100, 113, 126. Replacement Parts List No Revision G 09/2018

Daikin McQuay. Centrifugal Chiller WCC 100, 113, 126. Replacement Parts List No Revision G 09/2018 Replacement Parts List No. 700006100 Revision G 09/2018 Daikin McQuay Centrifugal Chiller WCC 100, 113, 126 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.daikinapplied.com

More information

McQuay. Seasonmaker Fan Coil. TSF, TSB, TSC Vintage C. Last Manufactured: Replacement Parts List No Revision D 09/2016

McQuay. Seasonmaker Fan Coil. TSF, TSB, TSC Vintage C. Last Manufactured: Replacement Parts List No Revision D 09/2016 Replacement Parts List No. 055211000 Revision D 09/2016 McQuay Seasonmaker Fan Coil TSF, TSB, TSC 021-151 Vintage C Last Manufactured: 1989 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

R-410A 50Hz & 60Hz. Renewal parts /3/ MODELS ONLY. Issue Date: September 07, 2011

R-410A 50Hz & 60Hz. Renewal parts /3/ MODELS ONLY. Issue Date: September 07, 2011 WATER-COOLED LIQUID CHILLERS HERMETIC SCROLL Renewal parts Supercedes: 20.26-RP (20) Form: 20.26-RP (9) MODELS YCWL0056, 0064, 0074, 0084, 0094, 0096, 004, 08, 026, 032, 056, 077, 098, 0200, 0230, 0240,

More information

McQuay. Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage B. FSCD, FSHD Design A (1)

McQuay. Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage B. FSCD, FSHD Design A (1) Replacement Parts List No. 055236500 Revision J 07/207 McQuay Large Capacity Fan Coil Direct Drive SCD, SHD 06-20 Vintage B FSCD, FSHD 06-20 Design A () To find your Daikin Applied parts distributor, call

More information

Daikin McQuay. Large Capacity Fan Coil Belt Drive. HCBB, HHBB Design 1. Replacement Parts List No Revision E 03/2018

Daikin McQuay. Large Capacity Fan Coil Belt Drive. HCBB, HHBB Design 1. Replacement Parts List No Revision E 03/2018 Replacement s List No. 700024000 Revision E 03/2018 Daikin McQuay Large Capacity Fan Coil Belt Drive HCBB, HHBB 08-30 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit

More information

Prodigy Eclipse 600, 800, 1000 Service Parts

Prodigy Eclipse 600, 800, 1000 Service Parts Prodigy Eclipse 600, 800, 000 Service Parts This part list contains the service parts for the Eclipse 600, 800 and 000 systems. The B series references changes to panels. The models that are covered include:

More information

McQuay. Incremental. MEK, MHK Vintage A. PKES, PKHS, PRKC, PRKH Design A (1) Replacement Parts List No Revision G 07/2017

McQuay. Incremental. MEK, MHK Vintage A. PKES, PKHS, PRKC, PRKH Design A (1) Replacement Parts List No Revision G 07/2017 Replacement Parts List No. 057110000 Revision G 07/2017 McQuay Incremental MEK, MHK 019-022 Vintage A PKES, PKHS, PRKC, PRKH 019-022 Design A (1) To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

MODELS YCAL0019, 0022, 0028, 0033, 0043, 0046, 0052, 0056, AND 0066

MODELS YCAL0019, 0022, 0028, 0033, 0043, 0046, 0052, 0056, AND 0066 AIR-COOLED LIQUID CHILLERS HERMETIC SCROLL Renewal Parts Supercedes: 50.67-RP (30) Form: 50.67-RP (5) MODELS YCAL009, 00, 008, 0033, 0043, 0046, 005, 0056, AND 0066 5009 STYLE "E" R-40A 5-60 TON 53-8 Kw

More information

McQuay. Cabinet Unit Heater. CHB, CHF Vintage A. FCHB, FCHF Design A (1) Last Manufactured: 2010

McQuay. Cabinet Unit Heater. CHB, CHF Vintage A. FCHB, FCHF Design A (1) Last Manufactured: 2010 Replacement Parts List No. 055211700 Revision G 05/2017 McQuay Cabinet Unit Heater CHB, CHF 003-015 Vintage A FCHB, FCHF 03-15 Design A (1) Last Manufactured: 2010 To find your Daikin Applied parts distributor,

More information

McQuay. Console Water Source Heat Pump. WMH, WMG, WMK, WCH, WCG 007, 009,012 Vintage B. Last Manufactured: 1998

McQuay. Console Water Source Heat Pump. WMH, WMG, WMK, WCH, WCG 007, 009,012 Vintage B. Last Manufactured: 1998 Replacement Parts List No. 057101600 Revision E 06/2015 McQuay Console Water Source Heat Pump WMH, WMG, WMK, WCH, WCG 007, 009,012 Vintage B Last Manufactured: 1998 To find your Daikin Applied parts distributor,

More information

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision C 03/2018

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision C 03/2018 Replacement s List 700024100 Revision C 03/2018 Daikin McQuay Large Capacity Fan Coil Direct Drive HCDB, HHDB 06-20 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit

More information

McQuay Climate Control Singer. Rooftop Unit. ER, R 160 Vintage A, B, C, D. Last Manufactured: 1996

McQuay Climate Control Singer. Rooftop Unit. ER, R 160 Vintage A, B, C, D. Last Manufactured: 1996 Replacement Parts List No. 779200600 Revision B 07/2007 McQuay Climate Control Singer Rooftop Unit ER, R 160 Vintage A, B, C, D Last Manufactured: 1996 To find your Daikin Applied parts distributor, call

More information

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision B 03/2016

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision B 03/2016 Replacement s List 70002400 Revision B 03/206 Daikin McQuay Large Capacity Fan Coil Direct Drive HCDB, HHDB 06-20 Design To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com

More information

Centrifugal Chiller PFH087 PL

Centrifugal Chiller PFH087 PL Centrifugal Chiller PFH087 PL-1003-17 Nomenclature 1 Unit Assy. Components Labels 2 Unit Assy. Components Labels No. Index Parts No. Parts Name Drwg. No. Parts Model & Specifi cation Q ty/unit PFH087 Wiring

More information

Daikin McQuay. Centrifugal Chiller WCC 100, 113, 126. Replacement Parts List No Revision F 07/2017

Daikin McQuay. Centrifugal Chiller WCC 100, 113, 126. Replacement Parts List No Revision F 07/2017 Replacement Parts List No. 700006100 Revision F 07/2017 Daikin McQuay Centrifugal Chiller WCC 100, 113, 126 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.daikinapplied.com

More information

MODELS YCWS0313, 0373, 0423, 0503, 0563, 0613 AND YCWS0663SC

MODELS YCWS0313, 0373, 0423, 0503, 0563, 0613 AND YCWS0663SC WATER-COOLED LIQUID CHILLERS HERMETIC SCREW 50 HZ RENEWAL PARTS New Release Form: 201.24-RP2 (303) MODELS YCWS0313, 0373, 0423, 0503, 0563, 0613 AND YCWS0663SC 264-587 kw R-22 STYLE B 380-415/3/50 MODELS

More information

Eclipse 2000 Service Parts

Eclipse 2000 Service Parts This part list contains the service parts for the Eclipse 000 systems. The models that are covered include: CME08 CP08 ERC08 Eclipse 000 Service Parts Table of Contents CME08 Cabinet Page CME08 Interior

More information

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage C. Last Manufactured: 1984

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage C. Last Manufactured: 1984 Replacement Parts List No. 055222700 Revision D 0/205 McQuay Central Station Air Handler LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL 37-72 Vintage C Last Manufactured: 984 To find your Daikin Applied parts

More information

McQuay. Large Capacity Fan Coil Belt Drive. SCB, SHB Vintage B. FCZA, FCZC, FCZH, FHZA, FHZC, FHZH S08 - S30 Design A (1)

McQuay. Large Capacity Fan Coil Belt Drive. SCB, SHB Vintage B. FCZA, FCZC, FCZH, FHZA, FHZC, FHZH S08 - S30 Design A (1) Replacement Parts List No. 055236400 Revision U 0/208 McQuay Large Capacity Fan Coil Belt Drive SCB, SHB 08-30 Vintage B FCZA, FCZC, FCZH, FHZA, FHZC, FHZH S08 - S30 Design A () To find your Daikin Applied

More information