QUOLIS 5000 DENTAL UNIT
|
|
- Anne Hawkins
- 5 years ago
- Views:
Transcription
1 QUOLIS 000 DENTAL UNIT INSTALLATION INSTRUCTIONS IMPORTANT This manual provides installation instructions for the BELMONT QUOLIS000 UNIT. The instructions contained in this booklet should be thoroughly read and understood before installing the chair and unit. After the installation has been completed, keep this manual in a safe place and refer to it for future maintenance. R
2
3 Intended Use of the Product This product is an active therapeutic device intended to administer or exchange energy of electric, air and water for the exclusive use for diagnoses, treatments and relative procedures of dentistry, and its characteristic is not in a potentially hazardous way between such energy and human body, taking account of the nature, the density and site of application of the energy. The product must be operated or handled by the qualified dentists or by dental staffs under the supervision of the dentist. Such dentists or dental staffs should instruct and/or assist the patients to approach to and leave from the product. Patients should not be allowed to operate or handle the product unless he/she is so instructed. The product is supplied together with the handpieces like electric micromotor, air turbine and/or motor, scaler and so on. Environmental Requirements Ambient Temperature Operating F to 0F Storage F to F Humidity 0 % - 0% Atmospheric Pressure.psi.psi Classification of Eqipment a. Type of shock protection : Class I Equipment b. Degree of shock protection : Type B Applied part c. Degree of protection against water ingress : Ordinary Equipment (All Products) d. Mode of operation : Continuous Operation e. Flammable Gasses : Not suitable for use in the presence of a flammable anesthetic mixture with air, oxygen, or nitrous oxide. f. Earth : Protective earth (ground) g. Hospital Grade Plug : Grounding reliability can be achieved only when the equipment is connected to an equivalent receptacle marked hospital only or hospital grade. CAUTION Ground reliability can only be achieved when the equipment is connected to an equivalent receptacle marked HOSPITAL only or HOSPITAL GRADE.
4 TABLE OF CONTENTS Page. Overview and Major Components Vac Pac System -. PMU System. Dimensions and Specifications Vac Pac System -. PMU System. Introduction Precautions -. Necessary tools. Unpacking of Units Swing Arm How to Install the Swing Arm. Junction Box How to Install the Junction Box. Balance Arm for the Doctor s Control How to Install the Balance Arm -. How to Plumb the Doctor s Control -. How to Plumb the Water Bottle -. How to Install the Foot Control. Monitor Mount (Optional) How to Install the Monitor Arm 9. Light Pole (Optional) How to Install the Light Pole (Optional) 0. Vac Pac (Optional) How to Install the Vac Pac 0-. How to Plumb the J-Box Utility. PMU (Optional) How to Install the PMU -. How to Install the Cuspidor Bowl -. How to Plumb the J-Box Utility -. How to install accessories. Final Adjustment Swing Arm -. How to Adjust the Swing Arm Friction -. How to Adjust the Rotation Tension of Assistant Arm -. How to adjust the water flow volume of Cup fill and Bowl Rins. Connect the Power Cable and Confirms functionlity Option How to Install the Tray Holder. Flow Diagram Doctor s Table Section -. Swing Arm Section -. Vac Pac Section -. PMU Section -. Junction Box Section -. Overall Unit Flow Diagram(Vac Pac System) -. Overall Unit Flow Diagram(PMU System). Electrical Diagram Chair Section -. Doctor s Table Section -. PMU Section. Location of Product Labels Floor Template
5 . Overview and Major Components -. Vac Pac System () Control Head () Main Control Panel () Digital Display () Handle () Handpiece Holders () Dr s Syringe () Handpiece Hose () Foot Control (9) Balance Arm (0) Dr Swing Arm] () Water Bottle () Junction Box () Dental Light Swing Arm () Light Pole () Assistant Instrument Holder () HVE () SE () Assistant s Syringe (9) Assistant Touch Pad (0) Solids Collector () Assistant Swing Arm () Assistant Holder Arm () Vacuum Pack Housing () Dental Light (*Note) Quolis 000 series does not include syringe tips. Syringe tips manufactured by DCI are compatible with this device. - -
6 . Overview and Major Components -. PMU System () Control Head () Main Control Panel () Digital Display () Handle () Handpiece Holders () Dr s Syringe (*) () Handpiece Hose () Foot Control (9) Balance Arm (0) Dr Swing Arm () Water Bottle () Junction Box () Dental Light Swing Arm () Light Pole () Assistant Instrument Holder () HVE () SE () Assistant s Syringe (*) (9) Assistant Touch Pad (0) Solids Collector () Assistant Swing Arm () Assistant Holder Arm () Assistant Section () Dental Light () Cuspidor Bowl () Cup filler switch and Bowl Rinse switch () Cup filler nozzle and Bowl Rinse nozzle () Q.D.Section (*Note) Quolis 000 series does not include syringe tips. Syringe tips manufactured by DCI are compatible with this device. - -
7 . Dimensions and Specifications -. Vac Pac System --. Dimensions - Inch / (mm) - Tolerance (± 0%) --. Specifications Power Consumption AC0V A Frequency Hz Fuse value ACV 0A Control Voltage DCV Dr s control Net Weight lbs ( kg) Swing Arm Net Weight lbs ( kg) (Without Dental Light) Vacuum Pack Net Weight lbs (0 kg) Junction Net Weight lbs ( kg) Doctor Table Maximum Load lbs ( kg) Operating Pressure Water 0-0 psi (0.-0. Mpa), Air psi (0. MPa) - -
8 . Dimensions and Specifications -. PMU System --. Dimensions - Inch / (mm) - Tolerance (± 0%) --. Specifications Power Consumption AC0V A Frequency Hz Fuse value ACV 0A Control Voltage DCV Dr s control Net Weight lbs ( kg) Swing Arm Net Weight lbs ( kg) (Without Dental Light) PMU Net Weight lbs (0 kg) Junction Net Weight lbs ( kg) Doctor Table Maximum Load lbs ( kg) Operating Pressure Water 0-0 psi (0.-0. Mpa), Air psi (0. MPa) - -
9 . Introduction -. Precautions for installation Do not connect to power supply other than 0V/0Hz. Ground the unit properly. Attach the junction box firmly to the floor. When electric micromotor (option) or electric scaler (option) is installed, please refer to the manual for the each device. Do not drop or hit the chair. When the installation process has been completed, verify that all the mechanical and electrical functions are working properly and that there is no evidence of oil, water or air leakage. Attach the dental chair to the floor before mounting the unit. Refer to the installation manual of Quolis 000 dental chair to know how to install the dental chair. Refer to Floor Template for connection of water, air, power, drain hose and vacuum hose. -. Necessary Tools Phillips screw drivers set #, #. Slotted screw driver Hex key wenches set (metric,.mm mm) Adjustable wrench(over mm) Long nose pliers Wire cutter Socket set mm, mm, / Level. Unpacking of units Each carton number corresponds to a component Box No. Module Doctor s control Swing arm (s) Vac pac PMU No. Check all the components and parts damage after unpacking. CAUTION No. No. No. Opening cartons with a sharp object may cause damage to parts - -
10 Box No. (Doctor s control) () Doctor's control assembly set () Junction box assembly set Junction box with cover set Duct hose 00mm pc. Utility package (air) () Balance arm end cap pc. () Stainless tray and non-slip pad set () Foot controller set () Syringe parts set () Operating manual, installation manual set () Miscellaneous parts for installation as follow Sleeve for / OD tubing pcs. Sleeve for / OD tubing pcs. Barb fitting for / OD tubing pcs. Barb fitting for / OD tubing pc. Hex plug pcs. Tubing / OD brown 00mm pc. Tubing / Green 00mm pc. Panhead Philips screw M x 0mm pcs Round head Philips wood screw M x mm pcs. Box No. (Swing arms) (9) Swing arm Assembly set (0) Water bottle pc () Lower tubing cover pc. () Quick disconnect adaptor for water bottle pc. () Swing arm locking pin for dental light pc. (For the swingmounted light only) () Miscellaneous Parts for installation as follow. Socket screw M0 x 0mm (for mounting) pcs. Socket screw M0 x 0mm (for level) pcs. Pan head Phillips screw M x mm pcs. Flat head screw M0 mm pc. / sleeve pcs. / sleeve pc. Box No. (Vac Pac) () Vac Pac Assembly set () Syringe parts set () Miscellaneous Parts for installation as follow. Socket screw M0 x 0mm (for mounting) pcs. / sleeve pcs. Barb fitting for / OD tubing pcs. Box No. (PMU) () PMU Assembly set (9) Junction Box Assembly set (0) Syringe parts set () Cuspidor Bowl Section Cup filler nozzle pc. Bowl Rinse nozzle pc. Basket Strainer & Cap pc. () Miscellaneous Parts for installation as follow. Socket screw M0 x 0mm (for mounting) pcs. / sleeve pcs. Barb fitting for / OD tubing pcs. () (), (), () () (0), () (), () () (9) (0) () - -
11 . Swing Arm -. How to Install the Swing Arm The swing arm assembly shall be mounted at the front of the chair under the seat.. Raise the seat frame of the chair as shown. CAUTION Seat Frame Failure to lift seat frame as shown can result in damage to paint finish of swing arm in subsequent steps.. Insert M0 x mm flat head screw in the threaded hole on the top side of the plate, center. Leave " from the top of screw to plate surface.. Raise the seat.. Attach swing arm assembly to chair by aligning M0 x mm screw with recess in front of the seat and slide screw into slot. Flange cover Flat Head Screw Swing arm plate. Locate - M0 x 0mm leveling set screws and insert into bottom side of swing arm plate.. Adjust the level of the swing arm plate with the four socket set screws.. Tighten the - M0 x 0 mm socket head screws. Lift the swing arm if needed.. Junction Box -. How to Install the Junction Box Refer to Floor Template for connection of water, air, power, drain hose and vacuum hose. X Socket head screws (M0 x 0mm) for level adjustment X Socket head screws (M0 x 0mm) for securing arm assembly to the chair. Raise the chair up. Turn off the power of the chair. Remove two slotted M x 0mm screws from each side of the pump cover and remove pump cover. Screws for J.box cover Main Switch Screws for pump cover. Place the junction box frame in front of the chair. (The plan of the plumbing position needs to be done in advance. See the flow diagram) Screws x. Attach the junction box frame to the floor with three M x mm round head philips wood screws. - -
12 . Balance Arm for the Doctor s Control -. How to Install the Balance Arm. Lower the chair. Balance arm cover. Insert the balance arm into the top of the swing arm.. Slide the balance arm cover off balance arm and route tubing and cables down into the swing arm. Make sure that the hoses are not twisted.. Remove the seat flange cover from chair by removing four M x mm screws and sub-link cover by removing two M x mm screws on the back of the chair cantilever lift arm. Screws for flange cover. Route umbilical tubing & wires from swing arm into chair. Tubing & wires should be routed over the top of the pivot bar in the front of the cantilever arm.. Feed umbilical down between nd pivot bar and into plastic retaining loop. Main Link Axis Flange cover Sub link cover Sub Link Axis Feed tubing between PCB box and Pump PCB box Route tubing and wires over the top of the pivot bar in front of the chair Tubing is routed through the plastic retainer loop and out thoroug the front of the chair Pump. Feed tubing between PCB box and pump and out to the front of the chair.. Slide in the balance arm cover and into the channels along the balance arm and the balance arm end cap with two M x 0mm screws. 9. Adjust M x mm balance arm friction adjustment screw (M x mm). End cap Screws Balance arm friction adjustment screw - -
13 -. How to Plumb the Doctor s Control CAUTION If Vac Pac or PMU is installed with Dr. table, run tubings for Vac Pac or PMU at the same time.. Cut the duct hose to desired length and insert it between retainers inside of the pump cover and the junction box.. Attach the manual on/off valve to the air supply pipe. Purge air through valve to clean debris. Attach automatic valve assembly for air to manual valve. Do the same thingfor the water assembly ordered with "city water" option. AIR Duct Hose If PMU is not purchased, Utility package for water becomes an option.the pressure gauge for air has higher scale range. WATER (Optional) Utility Package. As below drawing shows, connect tubings (,, & 0), connect V/V wire and connect the wire for protective earth (ground). / Tubing () / Sleeve / Sleeve / Tubing () / Sleeve / Sleeve / Tubing () / Tubing () V/V Wire (///) Groundings Earth (/Green) Pirot Air ( / ) Master Air ( / ) D view of air utility part - 9 -
14 . Connect wires in J Box as follows. Wiring in J Box () Dr.Table and () Dr.Table only PMU Line 9P P Char Line Dr.Table Line Do not connect 9P P P Do not connect Chair Line Dr.Table Line P P () PMU only 9P () Dr.Table and Vac Pac Vac Pac Line 9P Chair Line Dr.Table Line P P Do not connect PMU Line P P P Do not connect P Do not connect Chair Line -. How to Plumb the Water Bottle. Connect the tubing labeled, and to the manifold inside the junction box. Utility package for water is an option. Make sure that City/Bottle switch is equipped on the Swing Arm. CAUTION If City/Bottle switch is not equipped, do not connect green / tube (). This will cause water leak. Swing arm / Sleeve / Sleeve / Tubing () / Tubing (Green) (Option) City/Bottle switch / Tubing () WATER / Sleeve - 0 -
15 -. How to install the Foot Control Number Color (Size) Function (/ OD) Drive 0 (/ OD) In (/ OD) Chip (Air for spray, not used) 9 Gray (/ OD) Water (Pilot air for water for spray, not used). Insert foot control tubing through channel in chair base and feed through chairs into J.box.. Connect the tubing labeled,, 9 and 0 to the tubing from the doctor table. Note : Although the / OD gray tubing and yellow / OD tubing are not used, connect to prevent air leaks. Drive IN. Attach the foot control tubing to the chair base with a nylon clamp (see photo). Water Pilot Foot control tbings / Tubing (Gray) / Tubing () / Tubing () Chip Water Pilot Chip DRIVE IN / Sleeve / Sleeve / Tubing (). Monitor Mount(Optional) -. How to Install the Monitor Arm. Install the monitor arm to the swing arm. See - How to install swing arm.. Feed the cables thought the swing arm and the chair, and bring the end into the junction box.. Install the monitor mount to the monitor arm.. Connect the cables inside Junction box. Note : LCD monitors are not supplied from Belmont. The mounting holes on back of monitor should be designed for attachment of or 000 mm VESA mgt pattern. - -
16 9. Light Pole (Optional) 9-. How to Install the Light Pole. For installation of the dental light, see the installation and operation manual of Quolis dental light.. Position the swing arm to either side of the chair and lock it in place with the dental light locking pin. When you combine Dr. Table and PMU with a water bottle. Set Lock Pin on A position to avoid the interference of a bottle and a swing arm. CAUTION < A Position > Locking Pin Do not remove the cardboard paper put on the swing arm until the seat cushion has been attached to the seat frame with screws, otherwise the surface of the light pole will be scratched off when swinging the arm. 0. Vac Pac(Optional) 0-. How to Install the Vac Pac. Remove four screws M x mm and the flange cover of the chair.. Insert two M0 x 0mm socket head cap screws into the top threaded hole on the rear side of the chair. Screws should extend approximately " from chair. Screw for flange cover. Hook the assistant arm mounting bracket underneath the two socket head cap screws.tilt the bracket slightly and lift it. Place the lower edge of the mounting bracket on the projections of the flange. Socket head cap screw approx.. Tighten lower M0 x 0mm socket head cap screws through swing arm mounting bracket. Tighten all four screws. Projections of the flange. Route the umbilical tubing with unit umbilical down through chair, between the main link and sub link Axis, and bring the end to the junction box. Tie the tubing with the white nylon clamp. Make sure that hoses are not kinked Tighten Main Link Axis Sub Link Axis Nylon Clamp Projection of the flange - -
17 0-. How to Plumb the JBOX-Utility (Vac Pac). Cut the duct hose to desired length and insert it between retainers inside of the pump cover and the junction box.. Attach the manual on/off valve to the air supply pipe.purge air through valve to clean debris. Attach automatic valve assembly for air to manual valve. Do the same thing for the water assembly ordered with "city water" option.. As below drawing shows, connect tubings and wires. If connection end is plugged, use supplied / fitting. AIR Duct Hose / Sleeve / Sleeve WATER (Optional) Utility Package / Tube. Connect / Vacuum hose.. Connect wires under a pump cover. Vacuum Vac Pac Line Chair Line - -
18 . PMU(Optional) -. How to Install the PMU. Remove four screws M x mm and the flange cover of the chair. Screw for flange cover. Insert two M0 x 0mm socket head cap screws into the top threaded hole on the rear side of the chair. Screws should extend approximately " from chair. Socket head cap screw approx. Projections of the flange. Hook the assistant arm mounting bracket underneath the two socket head cap screws. Tilt the bracket slightly and lift it. Place the lower edge of the mounting bracket on the projections of the flange.. Tighten lower M0 x 0mm socket head cap screws through swing arm mounting bracket. Tighten all four screws. Tighten Projection of the flange. Route the umbilical tubing with unit umbilical down through chair, between the main link and sub link, and bring the end to the junction box. Tie the tubing with the white nylon clamp. Make sure that hoses are not kinked Main Link Axis Sub Link Axis Nylon Clamp - -
19 -. How to Install the Cuspidor Bowl.. Take the main cover off by unscrewing three screws.. Remove a cap bolt. Body Cap Bolt Cuspidor Bowl Washer. Insert Cuspidor Bowl into Rotation Axis. Do not forget to insert an attached washer. Main Cover. As below drawing shows, connect drain hose, tubings and wires. () We supply long hoses. As needed, cut them accordingly. () To avoid water leak, insert barb fittings to the end. (Use a connector, when an optional Cuspidor Drain Kit in installed) () Connect the drain hoses by a hose clamp. () Connect tubings by matching colors and numbers. () Connect wirings by using a P wire connector. Connect Wire P Connector / Sleeve hose clamp Cuspidor Drain Valve (Option) / Tube / Tube Green Connect tubings Connect Wirings. When connections have been completed, put the main cover and cap bolt back. CAUTION Please avoid the external force on Drain Hose, tubings and Wires. This will cause the malfunction or damage to the equipment. - -
20 -. How to Plimb the JBOX-Utility. Cut the duct hose to desired length and insert it between retainers inside of the pump cover and the junction box.. Connect wires in J Box as follows.. Attach the manual on/off valve to the air supply pipe.purge air through valve to clean debris. Attach automatic valve assembly for air to manual valve. Do the same thing for the water assembly ordered with "city water" option. Duct Hose AIR WATER (Optional) Utility Package Wiring in J Box () Dr.Table and PMU 9P PMU Line P Chair Line. Connect Vacuum Hose (/) and Drain Hose (/) Vacuum hose have uneven surface. We supply long hoses. As needed, cut them accordingly. Dr.Table Line P P () Dr.Table and Vac Pac Vac Pac Line 9P Chair Line Dr.Table Line P P Do not connect () Dr.Table only Vacuum Do not connect 9P Chair Line Drain Dr.Table Line () PMU only P P Do not connect 9P. As below drawing shows, connect tubings and wires. If connection end is plugged, use supplied / fitting.connect Dr. Table side wirings to the wirings on PMU side. PMU Line P P P Do not connect P Do not connect Chair Line Option for PMU only Do not Connect / Tube / Sleeve / Sleeve /Tube / Tube / Tube / Tube Green / Sleeve / Sleeve / Tube Connect to Dr.Table Line Pirot Air ( / ) V/V Wire (///) Groundings Earth (/Green) D view of air utility part - -
21 -. Installation of Accessories.. Install, Nozzles, Cap & Basket Strainer. Cap Basket Strainer Nozzles. Final Adjustments -. Swing Arm. Attach the lower tubing cover to the bottom of the swing arm mounting bracket with four M x mm.. Replace the chair pump cover and the junction box cover and fasten with M x 0mm screw and tighten firmly with a slotted screw driver. CAUTION Fasten the pump cover and junction box cover firmly with a screw driver with screws provided and tighten -. How to Adjust the Swing Arm Friction The friction of the swing arm for Doctor's control, dental light and monitor must be adjusted independently.. Adjust the M x mm socket set screw beneath the swing arm. Set screw Set screw -. How to Adjust the Rotation Tension of Assistant Arm.. Adjusting screw for vertical angle is located here. To access adjusting screw, pull the rubber cover off. -. How to adjust the water flow volume of Cupfiller and Bowl Rinse.. Adjust the water flow by pinch valves. Pinch Valves : Cupfiller Green : Bowl Rinse - -
22 . Connect the Power Cable and Confirms functionality.. Connect the power cables(0v), electrical cables and the connectors to the electrical receptacle inside the junction box for chair and unit. CAUTION Ground reliability can only be achieved when the equipment is connected to an equivalent receptacle marked HOSPITAL only or HOSPITAL GRADE.. Adjust the regulator pressures. Air : psi. Water (optional) : 0-0psi. When all of the installation work are done, turn the main switch on. Confirms that each part functions correctly. Then put the cover on. ON OFF. Option -. How to Install the Tray Holder The tray holder can be mounted at either side of the Doctor's control.. Fit the tray holder to the tray arm. Install the tray arm to beneath the Doctor's control with two screws M x mm. This can be installed on the other side. Two holes on the back - -
23 . Flow Diagram -. Doctor s control section - 9 -
24 -. Swing Arm Section Option Bottle water City Water (Option) City / bottle City / bottle Air regulator Air regulator -. Vac Pac Section - 0 -
25 -. PMU Section Cupfiller Nozzle Bowl Flash Nozzle Cuspider Bowl Syringe Vacuum Ejector Solid Collector Pinch Valve Air Solenoid Valve for Bowl Frash AIR Manifold WATER FLOW CONTROL FOR SYRINGE Water Pinch Valve Water Outlet Flow Control Solenoid Valve for Water Water Air / : Master Air IN(Option) / : Master Air OUT(Option) Green / : City Water Vacuum Hose / Drain Hose / / : Air / : Bottled Water - -
26 -. Junction Box Section / OD / OD Green / OD / OD / OD / OD VACUUM AIR WATER (Optional) (Drain For PMU only) - -
27 -. Overall Unit (Vac Pac System) VACUUM WATER (Optional) AIR (Drain for PMU only) - -
28 VACUUM WATER AIR (Drain for PMU only) -. Overall Unit (PMU System) - -
29 M Electric Diagram -. Chair Section FLASH [Remarks] Connector Symbol CN IL-P-SEN CN IL-P-SEN CN IL-P-SEN Plug CN IL-P-SEN dot indicates male pin side Cap CN IL-P-SEN CN IL-P-SEN Control P.C.B.(AGFS*0) XX-STD00/00TI CN IL-P-SEN CN-(-) IL-P-SEN CN IL-P-SEN ANDRA0 Potentiometer for Backrest EWS VDA S0 E CN-(-) IL-P-SEN Unused CN IL-P-SEN ANDR0A0 LIM NOL Limit STORE SW SW Potentiometer for Seat EWS VDA S0 E MODE SW (Proportional Solenoid Valve) SW CN-(-) IL-0P-SEN CN B0B-XASK- CN B0B-XASK- CN-(-) IL-P-SEN N.O. COM Chair Down Prohibition Safety Switch for Under Pump Cover CN9 B0B-XASK- CN-(-) IL-0P-SEN DNCSA0 (.) Serial Transmission (.) Serial Transmission CN0 IL-0P-SEN Chair Operation Prohibition NTC Thermistor Thermistor Thermistor for Solenoid Valves Chair upper frame XAP arth Line Base (.) Serial Reception (.) Serial Reception CN B0B-XASK- CN9 B09B-XASK- CN-(-) IL-P-SEN N.O. COM Chair Down Prohibition Safety Switch for Under Pump Cover COM Chair Operation Prohibition DNCSA0 P P LP AR Up Down Raise Reclining V Lock Cancel Safety Safety LED. COM COM P P LP AR Up Down Raise Reclining COM Up Down Raise Reclining Up/Down Slow Slide Backrest Slow Slide Lock Cancel Motor Green Gray ANFTA0 0 Green Gray ANFT9A0 Serial Communication Line Light / Pink Green Gray Light Trunk Line A for Touchpad SW XAP ANFTB0 Trunk Line for Relay ANFTA0 Trunk Line for Dental Light Power Source VLP To Serial Communication Line for Doctor Table NMFP ANFT0A0 XA9P ANFTA0 ANFTA0 D Light Communication Line 0 Trunk Line B for Touchpad SW Green Gray Pink Light / Trunk Line A for Membrane SW ANFTA0 COM (Distribution P.C.B. in the right side armrest) 0 CN B0P-NV Trunk Line ffor Chair Power Source CN9 IL-P-SEN Distribution P.C.B. (AGFSA0) XAP CN B0B-XASK-N-A CN B0B-XASK-N-A Backrest Slow Slide Lock Cancel COM Up/Down Slow Slide Com Up Down Raise Reclining Motor ANFT0A0 D Light PCB. XAP XAP Green Power Cable Section Green Gray ANFTA0 L N XA9P Trunk Line B for Membrane SW ANFTA0 CN B0B-XASK-N-A Relay P.C.B. RY-00 Trunk Line C for Membrane SW XAP Green Gray Pink Light / Green Gray Pink Light / CN9-0A (MOLEX) ANFTA0 XAP L N 0 0 Earth Green/ ANFU0A0 Transformer TK-0V-H Trunk Line C for Touchpad SW Safety LED. V P P LP Lock Cancel Safety COM AR Up Down Raise Reclining Safety LED. V P P LP Lock Cancel Safety COM AR Up Down Raise Reclining Green Gray 9V 0 0V Lock Trunk Line B for Solenoid Valve Fuse F 0A V CN BP-VH CN -0A Main Switch 9 0 COM P P LP AR Up Down Raise Reclining Armrest Membrane SW- R (AGFSA0) Armrest Membrane SW- L (AGFSA0) Gray ANFTA0 Main Power Switch Section Gray Backrest Slow VLP XA0P Touchpad Switch (AGFSA0) CN BP-VH SV Up/Down Slow Green ANFTA0 Transformer Section(0V) CN0-0A (MOLEX) Backrest Slow Slide SV Up/Down Slow Slide SV VLP Assistant Side ANETA0 Rotation Lock Motor Section (V) Motor TSM-CBC-LP-M-E / ANFUA0 Trunk Line for Capacitor SV CN Green Up B0P-NV SV Down CN SV -0A (MOLEX) Raise ANFTA0 SV Trunk LIne for Motor / Capacitor VLP Gray Reclining Up Down Capacitor uf Solenoid Valve Section (0V) Raise Reclining ANFTA0 VLP Trunk Line A for Solenoid Valve - -
30 - -. Dr.Table Section ANFT9XX Mini Air Switch(F/C) NO COM CN IL-P-SEN GND PERIO CN CN0 CN0 CN CN CN IL-P-SEN IL-P-SEN IL-P-SEN ENDO IL-P-SEN IL-P-SEN IL-P-SEN CN HP Holder SW PCB. Fourth Line ANFTXX IL-P-SEN Trunk Line for HP Holder CN IL-P-SEN CN Gray IL-P-SEN Green Solenoid Valve for Pilot AGFSXX HP Holder SW PCB. HP Holder SW PCB. HP Holder SW PCB. CN IL-P-SEN Unit P.C.B. (AGFSXX) CN IL-P-SEN LP CN -0(Gray)WAGO LP CN Water LP IL-P-SEN Air LP CN CN (.) Serial Transmission IL-P-SEN With PMU To Serial Communication Line (ASS) Both connectors to be connected, P & P) IL-P-SEN (.) Serial Reception ANFTXX CN Serial Communication Line CN IL-0P-SEN CN (.) Serial Transmission IL-P-SEN CN CN9 CN9 CN IL-P-SEN IL-P-SEN IL-P-SEN FLASH CN IL-P-SEN IL-P-SEN CN CN IL-P-SEN CN IL-P-SEN CN IL-P-SEN CN IL-P-SEN IL-P-SEN CN IL-P-SEN CN HP HP HP HP HP HP HP HP 0V 0V V IL-P-SEN HPSV HP CN HPSV HP IL-P-SEN HPSV HP HPSV HP - CN -0(Gray)WAGO CN -0(Gray)WAGO CN -0(Gray)WAGO CN IL-P-SEN CN0 IL-0P-SEN CN9 B0B-XASK-N-A () Serial Reception Junction Box Section - - XAP ANDT0XX Solenoid Valve for Pilot Air + Solenoid Valve for Spray ANDT0XX L Standard Spec. Syringe Turbine x XAP CN -(Green) (WAGO) Air SW IL-P-SCN POWER Fuse F 0A ANFU0XX Earth (Dr Table) ANFU0XX AGFLXX Main Air SW Section HP HP HP XAP Without PMU To Serial Communication Line (CH) Connect P connector only VFD- VFD- VFD- VFD-0 0V V VFD-RS VFD-R/W VFD-E Dynamic Output Dynamic Output Dynamic LED Dynamic LED Dynamic LED Dynamic Output Input A Input B Input C Input D Input E Input F Input G Input H Display LED. Display LED. Green Gray Green Green Gray ANFT9XX Power Source for Dental Light Air SW ANFT9XX Trunk line() for Dr PCB. Power Source ANFTXX ANFT9XX Trunk line() for Dr PCB. Power Source Trunk line () for Fuse Holder Trunk Line for Display AGFS0XX VLP ANFU9XX J-Box Gauge Clamp Section Trunk line () for Fuse Holder ANFTXX Trunk Line for Dental Light Power Source (JBOX) Chair Power Supply ANFTXX Chair Power Supply Section Gray B A A B A B A B A A A B B B 9 0 Gray ANFTXX XA-P XA-P CN PS-LA-P Green/ Power Cable(UL)JBOX AC IN N ANFT9XX Display (AGFS9XX) Trunk Line A for Dr Membrane SW Green CN ANFT99XX Doctor Membrane SW (AGFSXX) AGDR9XX ANFTA0 Trunk Line B for Dr Membrane SW Green Main Gauge Clamp Trunk line () for Fuse Holder ANFT0XX Trunk line B for V.V Power Source Green/ UP Rotation Direction Forword Rotation(Green) Down Reverse Rotation() Raise Spray Air() Lower Spray Water() Fuse A LED Dental Light Light Pack SELECT + Light Pack(Green) LOCK() MAIN(Green) STORE F(Function) Spray Timer Operation Switch AR P P LP Chair Operation Switch A0XDXX Fuse A VLP ANFTXX Trunk line C for V.V Power Source ANFTXX Trunk line () for Fuse Holder Earth With PMU Connect trunk line C for V.V from cuspidor ANFT9XX Transformer FK-0 Trunk line A for V.V Power Source V ANFT9XX 0V Transformer Section Without PMU Connect trunk line A and B To terminal on assistant side V - -
31 -. PMU Section Chair Control PCB. (AGFS**) CN-(-) IL-0P-SEN 0 ANFT9** XA9P A0Y9** 9 XA9P A0YA** 9 XA9P Touchpad Switch (AGFS**) Option Bowl Rinse Solenoid Valve G0K** Section XAP G0J** Bowl Rinse Solenoid Valve Section XAP G0** [Remarks] Connector Symbol XA... XA Connector VL... VL Connector Plug dot indicaters male pin side Cap XAP A0XZ** Cuspidor Section Cupfiller Switch Bowl Rinse Switch J Box Section N.O. COM N.O. COM G0** G0** CB Switch Section XAP XAP A0XV** A0XX** A0XW** XAP VLP G0Q** Gauge Clamp (Cuspidor) A0Y0** VLP Green/ A0Y** Earth (m) A0XY** Trunk Line for V Power Souce BOWL SV CUP SV CUP SW CUP Sensor CN IL-P-SEN CN9 IL-P-SEN CN IL-P-SEN POWER CN - (WAGO) Assistant PCB. (AGDJ**) LED Green(Power LED) CN B0B-XASK- LED Green(CupLED-Detect a cap) LED (CN - data transmission) LED (CN - data transmission) LED (Full capacity of cupfiller) CN Transmission Speed Normally # side(00bps) (# side 00bps) IL Connector Central Vacuum SW... Notched for # Pin side CN B0B-XASK- (Side View) CN-A B0B-XASK- CN-B B0B-XASK- CN IL-P-SEN CN IL-P-SEN CN IL-P-SEN Extra TXD A0Y** FULL Sensor LOCK (Chair Operation Prohibition) CN IL-P-SEN CN-B IL-P-SEN WRITE OUT CN0 Data input Normally # side (# side for writing of data) CN9 B0B-XASK- FLASH XA Connector... (Top View) CN IL-P-SEN CN IL-P-SEN RXD SIG-CUR A0Y** CN-A IL-P-SEN LOCK CN0 IL-P-SEN (Chair Operation Prohibition) CUR-HOLD XAP XAP XAP 9 9 Greem Gray Greem Gray Greem Gray Up Down Raise Reclining AR P P LP COM TXD SCLK RXD BUSY RESET CNVSS GND EXT COM BOWL CUP AR LP P P V Power Signal() Signal(Green) Signal() Signal() Trunk Line A for Touchpad SW Trunk Line B for Touchpad SW (for PMU) Trunk Line C for Touchpad SW (for PMU) Solenoid Valve for Bowl Rinse V--G-M-X0 - + Solenoid Valve for Bowl Rinse VDW-G--M Solenoid Valve for Cupfiller VDW-G--M Cupfiller Solenoid Valve Section Trunk Line for Solenoid Valve CB Switch Section Trunk Line A for CB Switch Trunk Line C for CB Switch TXD Safety SW for Dr.Table Arm Safety SW for Dr.Table Arm Trunk Line(Ass) B for Serial Communication Line TXD Trunk Line(Ass) A for Serial Communication Line To Chair Serial Communication Line(CH) To Dr.Table Serial Communication Line(Unit) Trunk Line B for CB Switch Connect to Trunk Line B for V/V Power Souce Trunk Line C for V/V Power Souce Connect to Trunk Line A for V/V Power Souce LED (CN - data transmission) Pin Number Arrangement... (Side View) - -
32 --.Higashishinsaibashi,Chuo-ku,Osaka,Japan BELMONT EQUIPMENT, A Division of Takara Belmont USA Inc. 0 BELMONT DRIVE, SOMERSET, NJ 0 GS- ZZ US. Location of the Product Labels -. Product label & ETL label are located under the doctor table. -. Product label (SERIAL No.) is located side of the assistant swing arm. Model QUOLIS000 UNIT Dental Delivery Unit Serial No. AW********* 00 **** Rated Voltage V ~ 0Hz Rated Current A Classification Manufactured ** 0 **** 00 Takara Belmont Corp. Product of Japan ETL LISTED CONFORMS TO UL STD CERTIFIED TO CAN/CSA STD C. NO. RECOGNIZED COMPONENT MEDICAL ELECTRICAL EQUIPMENT PART: GENERAL 0 REQUIREMENTS CONFORMS TO UL STD Product label (SERIAL No.) is located side of the doctor swing arm. -. Product label (SERIAL No.) is located side of the PMU swing arm. - -
33 . Floor Template -/ -/ AIR (/ THREADED PIPE) -/ -/ WATER (For option) (/ THREADED PIPE) GRAVITY DRAIN (-/ NORMAL PIPE) FOR PMU CENTRAL VACUUM (/ O.D. TUBE) -/ / TELECOMMUNICATIONS (-/ NORMAL PIPE) TRANSFORMER ELECTRICAL CONDUIT FOR QUAD BOX (/ O.D.) -/ -/ CENTRAL VACUUM (/ O.D. TUBE) TELECOMMUNICATIONS (-/ NORMAL PIPE) ELECTRICAL CONDUIT FOR QUAD BOX (/ O.D.) AIR (/ THREADED PIPE) WATER (/ THREADED PIPE) GRAVITY DRAIN (-/ NORMAL PIPE) -/ FINISHED FLOOR - 9 -
34 NOTE R BELMONT EQUIPMENT, Division of Takara Belmont USA, Inc. 0 Belmont Drive Somerset, New Jersey 0 U.S.A. TEL.:() / (00) -9 Fax.:()- / (00) 0-0 TAKARA CO, CANADA LTD. 0 S. Sheridan Way, Mississauga, Ont., LJM, Can. TEL.:(90) - Fax.:(90)-0 AFFY9B0
Quolis Series. Quolis 5000 Chair IMPORTANT
Quolis Series Quolis 000 Chair Model Q-000 INSTALLATION INSTRUCTIONS IMPORTANT This manual provides installation instructions for the Quolis Chair. The instructions contained in this booklet should be
More informationEvogue Dental Unit IMPORTANT
Evogue Dental Unit INSTALLATION INSTRUCTIONS IMPORTANT This manual provides installation instructions for the Evogue unit. The instructions contained in this booklet should be thoroughly read and understood
More informationQUOLIS DENTAL CHAIR. Parts List. Model : Q-5000 (AC-BEL5000) 120V/60Hz. Ver Feb 7, 2012
QUOLIS DENTAL CHAIR Model : Q-000 (AC-BEL000) 0V/0Hz Parts List Ver. 0. Feb, 0 IMPORTANT Not all of the parts indicated in these lists are available by itself. Some of the parts can only be supplied as
More informationBEL-20N CHAIR IMPORTANT
Series BEL-20N CHAIR Model : B-20N Installation Instructions IMPORTANT This manual provides installation instructions for the BEL-20N Chair. The instructions contained in this booklet should be thoroughly
More informationBEL-50 DENTAL CHAIR INSTALLATION INSTRUCTIONS IMPORTANT
DENTAL CHAIR BEL-0 IMPORTANT INSTALLATION INSTRUCTIONS This manual provides installation instructions for the BEL-0 Chair. The instructions contained in this booklet should be throughly read and understood
More informationRadius Cuspidor (for Cascade 1040 or Decade 1011/1021 Chairs)
INSTALLATION INSTRUCTIONS Radius Cuspidor (for Cascade 1040 or Decade 1011/1021 Chairs) You Will Need: Hex key set Level Large flat head screwdriver Pliers 1/2" and 9/16" wrench Cutters Before Beginning
More informationInstallation Instructions: Swing Mounted Units BDS-2575
Installation Instructions: Swing Mounted Units BDS-2575 X-Calibur Units Installation Instructions for BDS-2575 X-Calibur Dental Units 8-23-10 BDS Swing Mounted Units Installation Time: Approximately 2
More informationINSTALLATION INSTRUCTIONS
DENTAL UNIT AND CHAIR IMPORTANT INSTALLATION INSTRUCTIONS This manual provides installation instructions for Belmont CP-ONE. The instructions contained in this booklet should be thoroughly read and understood
More informationINSTALLATION INSTRUCTIONS
DENTAL CHAIR INSTALLATION INSTRUCTIONS IMPORTANT This manual provides installation instructions for BELMONT PROGRES. The instructions contained in this booklet should be thoroughly read and understood
More informationBEL-50N DENTAL CHAIR OPERATING INSTRUCTIONS IMPORTANT
DENTAL CHAIR BEL-50N IMPORTANT OPERATING INSTRUCTIONS This manual provides operating instructions for the BEL-50N Chair. The instructions contained in this booklet should be throughly read and understood
More informationAsepsis 21 Delivery Unit
INSTALLATION INSTRUCTIONS for the Console Mounted TM Asepsis 21 Delivery Unit SECTION I - REQUIREMENTS 1. PHYSICAL REQUIREMENTS... 1 2. ELECTRICAL REQUIREMENTS... 1 3. WATER SUPPLY REQUIREMENTS... 1 4.
More informationCLESTA LED DENTAL LIGHT
DENTAL LIGHT CLESTA LED DENTAL LIGHT TYPE 0 POLE MOUNT 0 CEILING MOUNT 05 TRACK MOUNT INSTALLATION INSTRUCTIONS R Table of Contents. Precautions for Installation. Overview and Major Components. Specifications
More informationSimplicity Magellan Unit
Simplicity Magellan Unit Installation, Operation & Care Manual DentalEZ MAKES YOUR PRACTICE PERFECT Table of Contents Section I Introduction Specifications... 2 Classifications... 2-3 Dimensions... 3 Basic
More informationA-dec 541 Delivery System and 545 Assistant s Instrumentation
Installation Guide A-dec 541 Delivery System and 545 Assistant s Instrumentation Before You Begin A-dec 545 12 O Clock Assistant s Instrumentation The instructions are the same for installing both the
More informationD-LUX DENTAL LIGHT INSTALLATION AND OPERATION INSTRUCTIONS. Model AL-711M Model AL-712M Model AL-715M
DENTAL LIGHT D-LUX TM Model AL-711M Model AL-712M Model AL-715M INSTALLATION AND OPERATION INSTRUCTIONS IMPORTANT After installation is completed, check all the bolts, screws and fasteners to confirm that
More informationA-dec O Clock Delivery System
Installation Guide A-dec 500 12 O Clock Delivery System Before You Begin A-dec 545 12 O Clock Assistant s Instrumentation Before starting the installation: Check with local building and code authorities
More informationProcenter Delivery, Console Mounted on an Elevance Chair Installation Guide
Procenter Delivery, Console Mounted on an Elevance Chair Installation Guide Language of origin: English Equipment Alert Do not remove wraps or packaging from the delivery flex arm assembly until it is
More informationaxcs Chair Mounted Unit Installation, Operation and Care Manual
axcs Chair Mounted Unit Installation, Operation and Care Manual DentalEZ Group 2500 Highway 31 South Bay Minette, AL 36507 Table of Contents Section I Introduction Introduction... 2-3 Specifications...
More informationInstallation Operation Maintenance Troubleshooting Version 1, Oct/09. Palm Beach
Installation Operation Maintenance Troubleshooting Version 1, Oct/09 1655 Palm Beach Congratulations! All of us at Summit Dental Systems want you to know that your 1655 Palm Beach Cuspidor has been built
More informationCASCADE CHAIR-MOUNTED HANDPIECE CONTROL WITH CASCADE MASTER SERIES TOUCH PAD
R A-DEC INC. 2601 CRESTVIEW DRIVE POST OFFICE BOX 111 NEWBERG, OREGON 97132 USA TELEPHONE (503)-538-9471 DESIGNATED E.U. REPRESENTATIVE: A-DEC DENTAL U.K., LTD. AUSTIN HOUSE 11 LIBERTY WAY ATTLEBOROUGH
More informationLoose Components. VetPro 5000 Wall / Cabinet Mount Installation. Applies to Models:
VetPro 5000 Wall / Cabinet Mount Installation warning Equipment not suitable for use in the presence of a flammable anesthetic mixture. Applies to Models: 8001-001 8001-002 8001-005 8001-006 Loose Components
More informationDENTAL UNIT AND CHAIR OPERATING INSTRUCTIONS
DENTAL UNIT AND CHAIR OPERATING INSTRUCTIONS IMPORTANT This manual provides operating instructions for CP-ONE. The instructions contained in this booklet should be thoroughly read and understood before
More informationaxcs Magellan CMU Installation, Operation and Care Manual
axcs Magellan CMU 123456789012 123456789012 123456789012 123456789012 Installation, Operation and Care Manual Table of Contents Section I Introduction Introduction... 2 Specifications... 3 Basic Components...
More informationSimplicity Hygiene Unit
Simplicity Hygiene Unit (Magellan Style) Installation, Operation & Care Manual DentalEZ MAKES YOUR PRACTICE PERFECT Table of Contents Section I Introduction Specifications... 3 Classifications... 3 Dimensions...
More informationA-dec 351 Assistant s Instrumentation on an A-dec 311/411/511 Dental Chair INSTALLATION GUIDE
A-dec 351 Assistant s Instrumentation on an A-dec 311/411/511 Dental Chair INSTALLATION GUIDE Contents Before You Begin.......... 2 Install the Rigid Arm....... 3 Connect the Electrical Wires and Data
More informationDENTAL UNIT INSTALLATION INSTRUCTIONS
DENTAL UNIT INSTALLATIN INSTUCTINS IMPTANT This manual provides installation instructions for the CLESTA-II. The instructions contained in this booklet should be thoroughly read and understood before installing
More informationInstallation Instructions: Over-The-Patient Units (& Cuspidors) BDS-2500 BDS-2505 BDS-2510 BDS-2515 BDS-2520
Installation Instructions: Over-The-Patient Units (& Cuspidors) BDS-2500 BDS-2505 BDS-2510 BDS-2515 BDS-2520 X-Calibur BDS Delivery Systems Installation Instructions for BDS-2500, 2505, 2510, 2515, 2520
More informationPerformer Delivery System (Performer I Chair - International, and Performer III Chair)
Performer elivery System (Performer I hair - International, and Performer III hair) I NSTLLTION UI Introduction This document contains installation instructions for the Performer elivery System (Performer
More informationTroubleshooting Guide: Elevance Delivery Systems
Troubleshooting Guide: Elevance Delivery Systems FOR USE BY MIDMARK TRAINED TECHNICIANS Contents Description / Links Troubleshooting Charts ICM Screens Assistant s Unit Instruments (Elevance & European)
More informationSimplicity Chair Mounted Unit
Simplicity Chair Mounted Unit Installation, Operation & Care Manual DentalEZ MAKES YOUR PRACTICE PERFECT Table of Contents Section I Introduction Specifications... 3 Classifications... 3 Dimensions...
More informationProcenter Delivery Mounted on a Free Standing Treatment Console (FTC) Installation
Procenter Delivery Mounted on a Free Standing Treatment Console (FTC) Installation Electrical Requirements: 24 VAC, 3.2 Amp 13VAC, 2 Amp Attention These instructions apply to Midmark cabinetry. For other
More informationInstallation Instructions for Swing Mount System
Table of Contents Page Unit Installation Notes 2 Swing Arm Assembly to Chair Installation 3 Delivery System Installation 4 Utility Center Installation 5 Page 1 of 5 Unit Installation Notes Before You Begin
More informationOperatory Ensemble Operatory Ensemble. Configurations
Operatory Ensemble Operatory Ensemble Configurations With Vac Pac Without Vac Pac or Cuspidor With cuspidor & assistant instruments With cuspidor Delivery system with swing-mount Bel-Halo light QDU-5871
More informationDENTAL CHAIR AND UNIT VOYAGER II
DENTAL CHAIR AND UNIT VOYAGER II Model VOYAGER IIL PARTS LIST TABLE OF CONTENTS BASE SECTION-1--------------------------------------------------------------------------------- 1 Page BASE SECTION-2---------------------------------------------------------------------------------
More informationWall / Casework Mounted Delivery Systems (Procenter)
20 20 0 0 40 40 2 3 0 4 60 60 5 6 7 80 80 00 00 2 3 4 Wall / Casework Mounted Delivery Systems (Procenter) Common Components...004-0859-99 2:00 / FTC Delivery Systems Side Delivery Systems... 004-0886-99
More informationOPERATING INSTRUCTIONS
DENTAL UNIT AND CHAIR OPERATING INSTRUCTIONS IMPORTANT This manual provides operating instructions for SP-CLEO The instructions contained in this booklet should be thoroughly read and understood before
More informationDENTAL LIGHT INSTALLATION AND OPERATION INSTRUCTIONS
DENTAL LIGHT 70 INSTALLATION AND OPERATION INSTRUCTIONS IMPORTANT After installation is completed, check all the bolts, screws and fasteners to confirm that they are securely fastened. TABLE OF CONTENTS
More informationDENTAL LIGHT 300LED DENTAL LIGHT OPERATING INSTRUCTIONS IMPORTANT
DENTAL LIGHT 300LED DENTAL LIGHT OPERATING INSTRUCTIONS TYPE 301 POLE MOUNT 302 CEILING MOUNT 305 TRACK MOUNT 320X SWING MOUNT IMPORTANT Thank you for purchasing TAKARA BELMONT product. This manual provides
More informationEquipment Order Guide
Equipment Order Guide Effective April 1, 2016 DCI EDGE Equipment Order Guide ORDERING INFORMATION When ordering, please include the following information: DCI requires Doctor, Clinic Name and Address before
More informationDENTAL CHAIR AND UNIT PARTS LIST
DENTAL CHAIR AND UNIT PARTS LIST R RAPPORT CHAIR SECTION PARTS LIST TABLE OF CONTENTS Page. BASE SECTION--------------------------------------------------------------. BASE SECTION--------------------------------------------------------------.
More informationMulti Pad for NLX/iMD Installation Manual
Multi Pad for NLX/iMD Installation Manual OM-E0651E Revision History Date 7. 2014 Purpose and version 1st edition (Ver.1.00) New Details Contents Installation Manual for NLX BF and Varios170 1. COMPONENTS...
More informationChair Mounted Unit. Installation, Operation and Care Manual. DentalEZ Group 2500 Highway 31 South Bay Minette, AL 36507
axcs Basic-Duo Chair Mounted Unit Installation, Operation and Care Manual DentalEZ Group 2500 Highway 31 South Bay Minette, AL 36507 Table of Contents Section I Introduction Introduction... 2 Specifications...3
More informationMounted Instrument Head
INSTALLATION INSTRUCTIONS for the Asepsis 21 Cabinet TM Mounted Instrument Head SECTION I - REQUIREMENTS 1. PHYSICAL REQUIREMENTS... 1 4. WATER SUPPLY REQUIREMENTS... 1 5. AIR SUPPLY REQUIREMENTS... 1
More informationInstallation Instructions: Side Delivery Units BDS-2555
Installation Instructions: Side Delivery Units BDS-2555 X-Calibur Units Installation Instructions for BDS-2555 X-Calibur Dental Units 7-18-06 BDS Side-Delivery Unit Installation Time: Approximately 1
More informationINSTALLATION INSTRUCTIONS
DENTAL UNIT AND CHAI INSTALLATIN INSTUCTINS IMPTANT This manual provides installation instruction for BELMNT SP-CLE. The instructions contained in this booklet should be thoroughly read and understood
More informationDECADE 1021 SOLO CHAIR
Owner's Guide DECADE 1021 SOLO CHAIR 85-2626-00 Warranty A-dec warrants its products against defects in material or workmanship for one year from time of delivery (except for handpieces which have a warranty
More informationOperatory Ensenble. Configurations. Operatory Ensenble
Operatory Ensenble Configurations With Vac Pac Without Vac Pac or Cuspidor With cuspidor & assistant instruments With cuspidor Delivery system with swing-mount light Operatory Ensenble QDU-5870 QDU-5670
More informationMirage Dental Delivery Unit MSP3500/3550 Installation Instructions
! Mirage Dental Delivery Unit MSP3500/3550 Installation Instructions TPC 851 S. Lawson St. City Of Industry, CA 91748 P626-810-4337 Fax 626-810-4245 REV. 1-1-13 Table on Contents: Page GENERAL INFORMATION
More informationSupplement to the January 1, 2017 Price Book
Sulement to the January 1, 2017 Price Book Effective Aril 1, 2017 PRICE CHANGES: BDS0050 ASSISTANT INTSTRUMENT VAC PAC REVISED WARRANTY SUPPLEMENT PRICES & WARRANTY EFFECTIVE Aril 1, 2017 Suersedes All
More informationDental Equipment Retail Price List April 2017
Dental Equipment Retail Price List April 2017 Standard Warranty Policy All Belmont products are guaranteed against mechanical, electrical and workmanship faults, under normal working conditions, for a
More informationforest dental australia affordable excellence + designer friendly
Component Catalogue 204 table of contents section pages light service items............................................ 2-3 handpiece controls..............................................4 arm systems................................................
More informationINSTRUCTIONS IMPORTANT
DENTAL UNIT 'Cabinet' Delivery System 'Cart' Delivery System OPERATING INSTRUCTIONS IMPORTANT This manual provides operating instructions for the CLESTA-II. The instructions contained in this booklet should
More informationCascade Master Series
Overview The Cascade Master Series option consists of five components, which control standard chair and delivery system functions. These components include: master touchpad, master 17-watt power supply,
More informationINSTALLATION INSTRUCTIONS CASCADE 3181 DUO DELIVERY SYSTEM TO PREFERENCECOLLECTION 5580
R A-DEC INC. 2601 CRESTVIEW DRIVE POST OFFICE BOX 111 NEWBERG, OREGON 97132 USA TELEPHONE (503)-538-9471 DESIGNATED E.U. REPRESENTATIVE: A-DEC DENTAL U.K., LTD. AUSTIN HOUSE 11 LIBERTY WAY ATTLEBOROUGH
More informationSpirit 2000 Series Installation Instructions
Model: SCT20 Catalog: 2100, 2105 PMU Mounted Catalog 2222, 2322 Cabinet Mounted Model: SDW-D Catalog: 2600 Wall Mounted Model: SDC-D Catalog: 2610 Cabinet Mounted Spirit 2000 Series Installation Instructions
More informationDENTAL UNIT INSTALLATION INSTRUCTIONS
DENTAL UNIT PEDESTAL TPE INSTALLATIN INSTUCTINS IMPTANT This manual provides installation instructions for the BELMNT CLESTA-II. The instructions contained in this booklet should be thoroughly read and
More informationPatient Chairs Operatories Delivery Units Lighting Seating Enhancements
Patient Chairs Operatories Delivery Units Lighting Seating Enhancements C L A S S I C O P E R A T O R I E S Backed by over 90 years of healthcare manufacturing experience, Midmark provides a full line
More informationX-Calibur BDS Delivery Systems
X-Calibur BDS Delivery Systems Table of Contents Page Customer Unit Identification Record 1 General Unit Anatomy 2 Types Of Units 3 Description of Components 5 Control Head Features 5 Cuspidor Features
More informationQuolis 5000 Operatory Ensemble
7950 Cherry Ave. Suite 103, Fontana, CA 92336 866.274.8351 f 951.848.9700 www.ashteldental.com Quolis 5000 Operatory Ensemble BRH00034 REV 100107 FinalBelmontCatalogDesign.indd 1 9/2/07 4:25:44 PM Q u
More informationOwner s Guide PERFORMER III
Owner s Guide PERFORMER III 85.2638.00 R ALPHABETICAL EQUIVALENT TO THE NUMERAL OF THE MONTH MANUFACTURED A B C D E F G H I J K L January February March April May June July August September October November
More informationGalaxy Wall / Cabinet Mounted Unit
Galaxy Wall / Cabinet Mounted Unit Installation, Operation & Care Manual DentalEZ MAKES YOUR PRACTICE PERFECT Table of Contents Section I Introduction Introduction... 2 Basic Components... 2 Classification...
More informationClassicSeries Compressor Installation
ClassicSeries Compressor Installation Applies to Models: CL21-115 Volts CL22, CL32, CL52-208- 230 Volts Equipment Alert Compressor system must be installed per local plumbing and electrical codes. Note:
More information1416 Cabinet Unit. Installation Operation Maintenance Troubleshooting Version Dec/17
Installation Operation Maintenance Troubleshooting Version Dec/17 1416 Cabinet Unit Page 1 of 16 Table of Contents Important Information... 3 Weight & Dimensions... 4 Operator s Instructions... 5 Flow
More informationPARTS MANUAL. SERIAL NO: to BAND SAWING MACHINE
PARTS MANUAL MODEL: TF-2025M SERIAL NO: 543-99101 to BAND SAWING MACHINE MACHINE SPECIFICATIONS MODEL VOLTAGE CYCLE PHASE SERIAL NO. For your information and future reference, insert pertinent data concerning
More informationDENTAL LIGHT 300LED DENTAL LIGHT OPERATING INSTRUCTIONS IMPORTANT
DENTAL LIGHT 300LED DENTAL LIGHT TYPE OPERATING INSTRUCTIONS 320M UNIT MOUNT IMPORTANT Thank you for purchasing TAKARA BELMONT product. This manual provides operating instructions for the 300LED DENTAL
More informationTable of Contents. Section I Introduction. Section V Operation. Section II Pre-installation. Section VI Care. Section III Installation
Table of Contents Section I Introduction Classifications... 2 Specifications... 2 Dimensions... 3 Unit Features... 4 Packaging... 5 Section II Pre-installation Utility Service Compartment... 6 Plumbing
More informationMicroprocessor Controlled Dental Vacuum System Installation Manual
Microprocessor Control System Installation Manual Microprocessor Controlled Dental Vacuum System Installation Manual Effective Date: 05-Aug-05 Review this entire booklet before starting any mechanical
More informationAssistant s Instrumentation T
Instructions for Use Assistant s Instrumentation 85.2610.00 T Copyright 2015 A-dec Inc. All rights reserved. A-dec Inc. makes no warranty of any kind with regard to this material, including, but not limited
More informationNextGen Cart Delivery Unit
NextGen Cart Delivery Unit Installation, Operation & Care Manual DentalEZ MAKES YOUR PRACTICE PERFECT Table of Contents Section I Introduction Specifications... 2 Classifications... 2 Dimensions... 3 Features
More informationSurface Mounted Bottle Fillers
BF & BF6 Series Surface Mount Bottle Fillers BF Series BF6 Series TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER:.800.9.960 Technical Assistance Fax:.66.8.89 NOTES TO INSTALLER:. Please leave this documentation
More informationDental Equipment Retail Price List April 2017
Dental Equipment Retail Price List April 2017 Standard Warranty Policy All Belmont products are guaranteed against mechanical, electrical and workmanship faults, under normal working conditions, for a
More informationSafe-T-element Installation Instructions
Safe-T-element Installation Instructions For: PTI STEZA (2x2 Burner Configuration) & PTI STEZB (3x1 Burner Configuration) Revision K (May. 3 2012) TABLE OF CONTENTS 1. PREPARATION... 3 1.1 General Safety
More informationOwner's Guide CASCADE 2671 DUO CART AND CASCADE 3171 DUO WALL-MOUNT
Owner's Guide CASCADE 2671 DUO CART AND CASCADE 3171 DUO WALL-MOUNT 85.2641.00 ALPHABETICAL EQUIVALENT TO THE NUMERAL OF THE MONTH MANUFACTURED A B C D E F G H I J K L January February March April May
More informationPowerAir Compressor Installation
PowerAir Compressor Installation Applies to Models: P21-115 Volts P22, P32-230 Volts P52, P72-230 Volts Equipment Alert Compressor system must be installed per local plumbing and electrical codes. Model
More informationA-dec 200 Service Guide Contents
A-dec 200 Service Guide 1 A-dec 200 Service Guide Contents Overview... 3 Get Support... 3 International Customer Service... 3 Other Sources of Information... 3 Electronic Documentation... 3 A-dec 200 System
More informationSimplicity Cart. Installation, Operation & Care Manual. Duo. Doctor s
Simplicity Cart Duo Doctor s Installation, Operation & Care Manual Table of Contents Section I Introduction Specifications... 2 Classifications... 2 Explanation of Symbols & Signs... 3 Dimensions... 3
More informationUser s and Installation Manual
Dry Vacuum System Part Numbers V3, V5, V7, 2V3, 2V3CT, 2V5, 2V5CT, 2V7, 3V5 and 4V5 User s and Installation Manual We Recommend Daily use of Monarch CleanStream TABLE OF CONTENTS Description Page Congratulations...4
More informationOPERATION AND MAINTENANCE INSTRUCTION MANUAL. AEU-707A & AEU-707AV2 Implant / Surgery Systems
OPERATION AND MAINTENANCE INSTRUCTION MANUAL AEU-707A & AEU-707AV2 Implant / Surgery Systems TABLE OF CONTENTS: Introduction.........................1 Package Contents....................1 Setting Up the
More informationVHM-P (Non-Locking) Variable Height Arm with VESA Mounting Plate for 75 x 75mm or 100 x 100mm applications
3875 Cypress Drive Petaluma, CA 94954 800.228.2555 +1.707.773.1100 Fax 707.773.1180 www.gcx.com VHM-P (Non-Locking) Variable Height Arm with VESA Mounting Plate for 75 x 75mm or 100 x 100mm applications
More informationMODELS CMA-180/180TALL Including 480V MACHINES PARTS MANUAL Rev 2.08A
MODELS CMA-180/180TALL Including 480V MACHINES PARTS MANUAL Rev 2.08A C M A D I S H M A C H I N E S 1 2 7 0 0 K N O T T A V E N U E GARDEN GROVE, CALIFORNIA 92841 800-8 5 4-6 4 1 7 FAX 714-895-2141 www.cmadishmachines.com
More informationMirage Dental Delivery Unit Model 2000 / 2015 Installation Instructions
Mirage Dental Delivery Unit Model 2000 / 2015 Installation Instructions 851 S. Lawson St. City Of Industry, CA 91748 P626-810-4337 Fax 626-810-4245 REV. 1-1-13 Each Mirage delivery unit will contain the
More informationSX4000. Dental Treatment Unit
SX4000 Dental Treatment Unit SX4000 2 Optimum dental workflow Reliability, durability and timeless design are the key elements of the SX4000 dental treatment unit from Siamdent. The SX4000 represents the
More informationMODEL CMA-44 PARTS MANUAL Rev 2.13
MODEL CMA-44 PARTS MANUAL Rev 2.13 CMA DISHMACHINES 12700 KNOTT AVENUE GARDEN GROVE, CALIFORNIA 92841 800-854-6417 FAX 714-895-2141 www.cmadishmachines.com Table of Contents CMA-44 1. PARTS MANUAL... 4
More informationTrack Light with Monitor Installation Guide
Track Light with Monitor Installation Guide This installation requires at least two service technicians. Track with light and monitor weight (max.) is 157 Lbs. (71 kgs). Applies to Models: 1531017 (-000
More informationINTRODUCTION TO SERVICING THE A-dec Handpiece Control Blocks
INTRODUCTION TO SERVICING THE A-dec Handpiece Control Blocks August, 2017 Presented by Mark Micucci Product Engineer Replacement Parts Industries, Inc. Course Overview The Handpiece Control Block (located
More informationLEAK TEST PROCEDURE APPLICABLE TO DC3 INTELLI-GRIP LIFTERS MODELS MRT4-DC3, MRTA8-DC3, MRTALP8-DC3 AND PC/P1-DC3 SERIES
LEAK TEST PROCEDURE APPLICABLE TO DC3 INTELLI-GRIP LIFTERS MODELS MRT4-DC3, MRTA8-DC3, MRTALP8-DC3 AND PC/P1-DC3 SERIES TESTING AND MAINTENANCE MUST BE DONE BY A QUALIFIED PERSON KEEP FOR FUTURE REFERENCE
More information(Refer to qualified personnel)
3875 Cypress Drive Petaluma, CA 94954 800.228.2555 +1.707.773.1100 Fax 707.773.1180 www.gcx.com Installation Guide VHM-P (Non-Locking) and VHM-PL (Locking) Variable Height Arm (Slide-Above-Arm Configuration)
More informationPlanmeca Compact i Classic *
KI Page 1(17) Planmeca Compact i Classic * Dental unit with unit-integrated chair Planmeca Compact i Classic is the ideal choice for the needs of general dentistry. It provides a cost-effective dental
More informationOPERATION MANUAL OM-K
UltraSonic Polisher OPERATION MANUAL OM-K0517 001 1. P 2 2. P 3 3. P 4 4. P 6 5. P 7 6. P 8 7. P 9 8. P 9 9. P10 10. P11 11. P11 12. P12 13. P13 CONTENTS 1. CAUTIONS FOR HANDLING AND OPERATION P16 2. SPECIFICATIONS
More informationWL250 TOWER DRAWING AND PARTS LIST
WL250 TOWER DRAWING AND PARTS LIST Yellow = Consumables Green = Recommended spare parts WL250 Manual Page 29 Revision: 10 29 2018 No WLCP Part No. Consumables Description Part No Cold Only Hot & Cold Stocked?
More informationRev.2.05 www.cmadishmachines.com Table of Contents EST-44 1. PARTS MANUAL... 3 1.1. Initial Parts Kit... 3 1.2. Exploded View Drawings... 4 1.2.1. Cabinet Assembly... 4 1.2.2. Control Box Assembly... 5
More informationwww.cmadishmachines.com Table of Contents CMA-44 1. PARTS MANUAL... 4 1.1. Initial Parts Kit (P/N 13996.81)... 4 1.2. Initial Parts Kit (P/N 13996.80)... 5 1.3. Exploded View Drawings... 6 1.3.1. Cabinet
More informationwww.cmadishmachines.com Table of Contents CMA-66 1. PARTS MANUAL... 4 1.1. Initial Parts Kit (P/N 13996.81)... 4 1.2. Initial Parts Kit (P/N 13996.80)... 5 1.3. Exploded View Drawings... 6 1.3.1. Cabinet
More informationInstallation Instructions
Installation Instructions For PTI STEZA C (2x2 Burner Configuration) & PTI STEZB C (3x1 Burner Configuration) Revision E Safe-T-Element Installation Instructions Table of Contents 1. PREPARATION..3 1.1
More informationDENTAL CHAIR PARTS LIST
DENTAL CHAIR PARTS LIST CLESTA CHAIR PARTS LIST TABLE OF CONTENTS BASE SECTION PAGE 1 FLANGE SECTION PAGE 3 SEAT SECTION PAGE 5 BACKREST SECTION PAGE 6 HEADREST SECTION PAGE 7 FOOT CONTROL SECTION PAGE
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Accessory REMOTE CONTROL Application 2012 ODYSSEY (EXCEPT LX) Publications No. AII 46745 Issue Date SEP 2011 PARTS LIST Remote Control Engine Starter Unit Kit P/N 08E91-E22-101A
More informationTHIS PRODUCT IS FOR PROFESSIONAL LABORATORY USE ONLY USER'S MANUAL. WELLS ENGINE UNIT 230 VOLT Product No. U905, U906, U907, U908
DENTAL, INC. TECHNICAL BULLETIN U807-022510 5860 FLYNN CREEK ROAD READ ALL INSTRUCTIONS P.O. BOX 106 BEFORE PROCEEDING COMPTCHE, CALIFORNIA, U.S.A. 95427 SAVE THIS FOR FUTURE REFERENCE THIS PRODUCT IS
More informationVacuum pump system type
type VS*P Vacuum component C O N T E N T S Series variation 166 20 mm width universal type (/M) 168 10.5 mm width universal type (/M) 184 31.5 mm width discrete type (VSQP) 214 11 mm pitch manifold dedicated
More informationINSTRUCTIONS FOR USE CASCADE 2615 CART AND 3175 WALL MOUNT
INSTRUCTIONS FOR USE CASCADE 2615 CART AND 3175 WALL MOUNT 85.0664.00 R Warranty ALPHABETICAL EQUIVALENT TO THE NUMERAL OF THE MONTH MANUFACTURED A B C D E F G H I J K L January February March April May
More informationIMPORTANT! READ BEFORE INSTALLING!
1360 Redwood Way, Suite A Petaluma, CA. 94954 TEL: (707) 763-7799 Toll free in the USA (800) 767-9543 FAX (707) 763-2631 www.xandexsemi.com EMAIL: info@xandex.com Instructions for Xandex Pneumatic Controller