Chapter 15. Fire Hose. Answer Key. Firefighter I

Size: px
Start display at page:

Download "Chapter 15. Fire Hose. Answer Key. Firefighter I"

Transcription

1 Chapter 15 Fire Hose Firefighter I Terms 1. Fire Hose A flexible, portable tube manufactured from water tight materials in 50 to 100 foot (15 to 30 m) lengths that is used to transport water from a source or pump to the point it is discharged to extinguish fire. 2. Supply Hose Hose that is designed for the purpose of moving water between a water source and a pump that is supplying attack hoselines or fire suppression systems. 3. Attack Hose Hose that is used by trained firefighters to combat fires. 4. Fire Department Connection (FDC) Point at which the fire department can connect into a sprinkler or standpipe system to boost the water flow in the system. 5. Soft Sleeve Hose Large-diameter, collapsible piece of hose used to connect a fire pump to a pressurized water supply source; sometimes incorrectly referred to as soft suction hose. 6. Suction Hose Intake hose that connects pumping apparatus or portable pump to a water source. 7. Hard-Suction Hose Rigid, noncollapsible hose that operates under vacuum conditions without collapsing, allowing a pumping apparatus or portable pump to draft water from static or nonpressurized sources (lakes, rivers, wells, etc.) that are below the level of the fire pump, usually available in 10-foot (3 m) sections. 8. Threaded Coupling Male or female coupling with a spiral thread. 9. Nonthreaded Coupling Coupling with no distinct male or female components. Also called Storz Coupling or sexless coupling. 10. Shank Portion of a coupling that serves as a point of attachment to the hose. 11. Higbee Cut Special cut at the beginning of the thread on a hose coupling that provides positive identification of the first thread to eliminate cross-threading. 12. Higbee Indicators Notches or grooves cut into coupling lugs to identify by touch or sight the exact location of the Higbee Cut. 13. Spanner Wrench Small tool primarily used to tighten or loosen hose couplings; can also be used as a prying tool or a gas key. 14. Quarter-Turn Coupling Nonthreaded (sexless) coupling with two hook-like lugs that slip over a ring on the opposite coupling and then rotate 90 degrees clockwise to lock. 15. Storz Coupling Nonthreaded (sexless) coupling commonly found on large-diameter hose. Nonthreaded fire hose couplings have been used in the North American fire and emergency services since the early 1900s. With this type of coupling, the mating of two couplings is achieved with locks or cams without the use of screw threads. 16. Wye Hose appliance with one female inlet and multiple male outlets, usually smaller than the inlet. Outlets are also usually gated. 17. Siamese Hose appliance used to combine two or more hoselines into one. The Siamese has multiple female inlets and a single male outlet. An example of a Siamese is a fire department connection. 18. Water Thief Any of a variety of hose appliances with one female inlet for 2½ -inch (65 mm) or larger hose and with three gated outlets, usually two 1½-inch (38 mm) outlets and one 2½-inch (65 mm) outlet. 19. Adapter Device for connecting hose couplings with dissimilar threads but with the same inside diameter. 20. Fitting Device that facilitates the connection of hoselines to provide an uninterrupted flow of extinguishing agent. 1

2 21. Reducer Fitting used to attach a smaller hose to a larger hose. The female end has the larger threads, while the male end has the smaller threads. 22. Hydrant Wrench Specially designed tool used to open or close a hydrant and to remove hydrant caps. 23. Hose Bed Main hose-carrying area of a pumper or other apparatus designed for carrying hose. 24. Finish Arrangement of hose usually placed on top of a hose load and connected to the end of the load. 25. Flat Load Arrangement of fire hose in a hose bed or compartment in which the hose lies flat with successive layers one upon the other. 26. Accordion Load Arrangement of fire hose in a hose bed or compartment in which the hose lies on edge with the folds adjacent to each other. 27. Horseshoe Load Arrangement of fire hose in a hose bed or compartment in which the hose lies on edge in the form of a horseshoe. 28. Dutchman Extra fold placed along the length of a section of hose as it is loaded so that its coupling rests in proper position. 29. Preconnect Attack hose connected to a discharge when the hose is loaded; this shortens the time it takes to deploy the hose for fire fighting. 30. Booster Hoseline Noncollapsible rubber-covered, rubber-lined hose usually wound on a reel and mounted somewhere on the apparatus and used for extinguishment of incipient and smoldering fires. This hose is most commonly found in ½-, ¾-, and 1-inch (13 mm, 19 mm, and 25 mm) diameters and is used for extinguishing lowintensity fires and overhaul operations. 31. Four-Way Hydrant Valve Hose appliance that is attached to the hydrant to permit additional supply hoses to be attached without interrupting the flow of water. 32. Open Butt The end of a charged hoseline that is flowing water without a nozzle or valve to control the flow. True/False 1. True. 2. False. The traditional length of a section of fire hose in North America is 50 feet (15 m). 3. True. 4. True. 5. False. Hard-rubber booster hose only requires rinsing with clear water. 6. False. Hard intake hose may be placed back on the apparatus while wet. 7. True. 8. True. 9. False. Preconnected hose loads for attack lines are placed in an area other than the main hose bed. 10. True. 11. False. Making a hard intake connection is more difficult than connecting soft intake hose. 12. True. 13. False. When advancing hoseline up and down a stairway, hose should be uncharged when conditions allow. 14. True. 15. True. 2

3 Identification Hose Rolls 1. Donut Roll 2. Self-Locking Twin Donut Roll 3. Straight Roll 4. Twin Donut Roll Hose Loads 1. Accordion Load 2. Combination Load 3. Flat Load 4. Horseshoe Load Matching Causes of Fire Hose Damage Types of Valves Hose Tools 1. D 1. A 1. E 6. H 2. F 2. D 2. D 7. B 3. E 3. B 3. C 8. A 4. B 4. C 4. I 9. F 5. C 5. G 6. A Multiple Choice 1. C 2. B 3. A 4. A 5. D 6. A 7. C 8. B 9. D 10. B 11. B 12. B 13. A 14. D 15. B 16. D 17. B 18. A 19. B 20. C Short Answer 1. Single-jacket Double-jacket Rubber single-jacket Hard-rubber or plastic noncollapsible 2. Melt ice with steam-generating device Chop hose loose with axes Leave hose until weather warms enough to melt ice 3

4 3. Evidence of dirt or debris on hose jacket or couplings Damage to hose jacket Coupling loosened from hose Damage to male and female threads Obstructed operation of swivel Absence of well-fitting gasket in swivel 4. Avoid dropping and/or dragging Do not permit vehicles to drive over Inspect when hose is washed and dried Remove gasket and twist swivel in warm, soapy water Clean threads to remove tar, dirt, gravel, and oil Inspect gasket and replace if cracked or creased 5. Answers may vary; students should include at least three of the following: Check gaskets and swivel before connecting any coupling Keep flat sides of hose in same plane when two sections of hose are connected Tighten couplings hand tight Remove kinks and twists from hose when bent to form loop in hose bed Make short fold or reverse bend (called a Dutchman) in hose during loading process so that couplings are not too close to front or rear of hose bed and will not flip over when pulled out of bed Load large-diameter hose [3½ inch (90 mm) or larger] with all couplings near front of bed Do not pack hose too tightly 6. Do not ride in standing position when apparatus is moving Drive no faster than 10 mph (16 km/h) slower speed allows couplings to clear tailboard as hose leaves bed Deploy hose to one side of roadway so that other apparatus are not forced to drive over it 7. Answers may vary; students should include at least four of the following: Check for and remove kinks and bends from hoselines as advanced Bleed air from hoseline as it is being charged and before entering building or fire area Position nozzle operator and all members of hose team on same side of hoseline Check for heat using back of gloved hand before opening door Stay low and avoid blocking ventilation openings Chock self-closing doors to prevent door from closing and pinching hoseline 4

5 Crossword Across 4. Quarter-turn coupling 5. Hard suction hose 7. Booster hoseline 9. Soft sleeve hose 12. Reducer 14. Dutchman 15. Preconnect 16. Wye Down 1. Fire hose 2. Adapter 3. Finish 5. Higbee cut 6. Nonthreaded coupling 8. Attack hose 10. Storz coupling 11. Supply hose 13. Fitting 5

Essentials of Fire Fighting,

Essentials of Fire Fighting, Essentials of Fire Fighting, 5 th Edition Chapter 13 Fire Hose Chapter 13 Lesson Goal After completing this lesson, the student shall be able to use, care for, and perform maintenance on fire hose, couplings,

More information

TWO FULLY EQUIPPED PUMPERS STATIC AND PRESSURIZED WATER SOURCES REFERENCES: ESSENTIALS OF FIRE FIGHTING, FOURTH EDITION, IFSTA, CHAPTERS 11 AND 12

TWO FULLY EQUIPPED PUMPERS STATIC AND PRESSURIZED WATER SOURCES REFERENCES: ESSENTIALS OF FIRE FIGHTING, FOURTH EDITION, IFSTA, CHAPTERS 11 AND 12 INSTRUCTOR GUIDE TOPIC: BACK TO BASICS: ESTABLISHING SUPPLY LINES TIME REQUIRED: THREE HOURS MATERIALS: TWO FULLY EQUIPPED PUMPERS STATIC AND PRESSURIZED WATER SOURCES REFERENCES: ESSENTIALS OF FIRE FIGHTING,

More information

ESCONDIDO FIRE DEPARTMENT TRAINING MANUAL ENGINE MODULE HOSE PAGE 1 OF 20 Supply Hose Lays Revised

ESCONDIDO FIRE DEPARTMENT TRAINING MANUAL ENGINE MODULE HOSE PAGE 1 OF 20 Supply Hose Lays Revised HOSE 12-01-16 PAGE 1 OF 20 There are five base North Zone supply hose lays: Forward Lay Spotting a Hydrant Stationary Lay Reverse Lay Split Lay Escondido Fire Department Core Hose Lays The Escondido Fire

More information

ESCONDIDO FIRE DEPT TRAINING MANUAL Section ENGINE MODULE Page 1 of 12 Special Operations Revised

ESCONDIDO FIRE DEPT TRAINING MANUAL Section ENGINE MODULE Page 1 of 12 Special Operations Revised ENGINE MODULE Page 1 of 12 SPECIAL HOSE OPERATIONS The information presented in this section covers a variety of hose-handling methods. These special operations include: Connecting hoses to fire department

More information

ADO-Pumping Apparatus Manipulative Skill Objectives PREVENTIVE MAINTENANCE

ADO-Pumping Apparatus Manipulative Skill Objectives PREVENTIVE MAINTENANCE ADO-Pumping Apparatus Manipulative Skill Objectives PREVENTIVE MAINTENANCE 1. Perform and document routine tests, inspections, and servicing functions on specified systems and components. A. For a fire

More information

ENGINE COMPANY OPERATIONS AND ASSIGNMENTS

ENGINE COMPANY OPERATIONS AND ASSIGNMENTS SOG 1-3 ENGINE COMPANY OPERATIONS AND ASSIGNMENTS A. Scope: This operational guideline shall be utilized for Engine Company Operations. Firefighters must possess the skills required to fulfill their designated

More information

LEVEL 2 DEFENSIVE Standard Equipment Guide

LEVEL 2 DEFENSIVE Standard Equipment Guide LEVEL 2 DEFENSIVE Standard Guide This guidance document was developed to assist NWT fire departments with identifying the minimum equipment required for a Standard - Level 2 Defensive fire service as defined

More information

Lightweight Aluminum Alloy Adapters

Lightweight Aluminum Alloy Adapters Lightweight Aluminum Alloy Adapters Double Swivel Female......for adapting from male to female. Made from extruded lightweight aluminum alloy, then hardcoated to resist corrosion and abrasion. Ship. wt.

More information

STANDARD LEVEL 2 DEFENSIVE Standard Firefighter Training I Minimum Equipment List

STANDARD LEVEL 2 DEFENSIVE Standard Firefighter Training I Minimum Equipment List STANDARD LEVEL 2 DEFENSIVE Standard Firefighter Training I Minimum Equipment List The NWT has established recommended operational service levels which may be further broken down into sections to fit local

More information

WATER SUPPLY AND DISTRIBUTION SYSTEMS

WATER SUPPLY AND DISTRIBUTION SYSTEMS WATER SUPPLY AND DISTRIBUTION SYSTEMS COUPLINGS AND ADAPTERS ANGUS CORRU-GRIP COUPLINGS The Angus Corru-Grip Coupling assemblies are the simplest and among the most reliable supply hose couplings available.

More information

Chapter Quiz. Directions: Write the correct letter on the blank before each question.

Chapter Quiz. Directions: Write the correct letter on the blank before each question. Chapter 12 Quiz Name: Date: Directions: Write the correct letter on the blank before each question. Objective 1: Describe dry-barrel and wet-barrel hydrants. 1. Most fire hydrants are made of: (605) A.

More information

Tyger Drafting Eductors

Tyger Drafting Eductors - Tyger Drafting Eductors Pump it dry DRAFT USING SOFT HOSE! VITA MOTIVATOR P.O. Box 8139 Englewood, NJ 07631 201-567-1151 : fax 201-734-8482 michaels.greene@att.net t Tyger Drafting Tyger Eductor Drafting

More information

Draft Commander 3000 Mobile Fire Pump Testing & Training Specifications Municipal/County/Rural/Commercial/Industrial

Draft Commander 3000 Mobile Fire Pump Testing & Training Specifications Municipal/County/Rural/Commercial/Industrial Draft Commander 3000 Mobile Fire Pump Testing & Training Specifications Municipal/County/Rural/Commercial/Industrial MODEL NUMBER DC1911-3000 AT/AL/MC Draft Commander 3000 Specifications MODEL NUMBER DC1911-3000

More information

Apparatus Placement. Was this fire apparatus placed properly?

Apparatus Placement. Was this fire apparatus placed properly? Was this fire apparatus placed properly? 1 There was 200 feet of skid mark This impact sent two patients from the civilian vehicle to a trauma center In front of the fire apparatus, fire crews were working

More information

Standardization of Fire Apparatus

Standardization of Fire Apparatus HORRY COUNTY FIRE / RESCUE DEPARTMENT PROUD * PREPARED * PROFESSIONAL STANDARD OPERATING GUIDELINE APPROVED BY GARRY ALDERMAN, FIRE CHIEF: DATE: September 24, 2011 SOG 726 Standardization of Fire Apparatus

More information

ADAPTERS & VALVES CAPS GASKETS STORZ ADAPTERS THREADED ADAPTERS. /adapters 2 1 /2" 3" 4" 4 1 /2" 5" 6" AC728: Male

ADAPTERS & VALVES CAPS GASKETS STORZ ADAPTERS THREADED ADAPTERS. /adapters 2 1 /2 3 4 4 1 /2 5 6 AC728: Male ADAPTERS & VALVES CAPS GASKETS STORZ ADAPTERS THREADED ADAPTERS VALVES DOUBLE SWIVEL FEMALE......for adapting from male to female. Made from extruded lightweight aluminum alloy, then hardcoated to resist

More information

Driver/Operator Program Part III - Tanker

Driver/Operator Program Part III - Tanker Driver/Operator Program Part III - Tanker Overview The Driver/Operator Preparation Program Part II is designed to standardize the training and release of driver/operators within the company; the intent

More information

Fire Engine Information

Fire Engine Information Fire Engine Information City of Thornton Fire Engine 71 2001 American La France This engine was built entirely by Freightliner/American La France. The National Fire Protection Association (NFPA) and Insurance

More information

HEAVY-DUTY VALVES. *Limited to Manufacture Defects. Operating Pressure (psi) " Stainless Steel " Polymer

HEAVY-DUTY VALVES. *Limited to Manufacture Defects. Operating Pressure (psi)  Stainless Steel  Polymer AKRON BRASS COMPANY PH. 800.228.1161 (330.264.5678) akronbrass.com Heavy Duty Brass Swing-Out Valves Akron Brass offers a wide variety of apparatus valves to meet the demands of today s fire service. All

More information

SM64052 Maintenance & Repair Manual Commercial 2" Unisex Coupling - Valved Model 64052

SM64052 Maintenance & Repair Manual Commercial 2 Unisex Coupling - Valved Model 64052 Aerospace Group Conveyance Systems Division Carter Brand Ground Fueling Equipment SM64052 July 2004 Applicable additional manuals: SM64051 Commercial 2" Unisex Coupling, Non-Valved Maintenance & Repair

More information

Pumping Apparatus Driver/Operator Types of Apparatus Equipped with a Pump. Chapter Test

Pumping Apparatus Driver/Operator Types of Apparatus Equipped with a Pump. Chapter Test Chapter 1 Test Name: Date: Directions: Write the correct letter on the blank before each question. Objective 1: Describe fire department pumpers. 1. The main purpose of fire department pumpers is to: (13)

More information

Basalt Fire-Rescue Engine 43 Inspection

Basalt Fire-Rescue Engine 43 Inspection Updated 8/9/17 Date of inspection OIC Truck Cab Map book/reference book/sop book HazMat pocket guide (glovebox) CO Monitor Motorola portable radio (1 with headset for driver/operator) (3) Traffic vests

More information

HASTINGS BRASS FOUNDRY LTD.

HASTINGS BRASS FOUNDRY LTD. HASTINGS BRASS FOUNDRY LTD. PROUD MANUFACTURER OF FIRE FIGHTING EQUIPMENT WORKING TOGETHER SINCE 1916 HASBRA FIRE FIGHTING EQUIPMENT CONTENTS HB10S Wrench Set (Bracket & 2 Wrenches)...Page 1 HB10 Wrench

More information

The requirements of this standard shall apply to the following coupling and adapters in the sizes defined in Section 1.1.

The requirements of this standard shall apply to the following coupling and adapters in the sizes defined in Section 1.1. NFPA STANDARDS DEVELOPMENT SITE SECOND DRAFT REPORT Closing Date: July 19, 2013 NOTE: All Public Comment must be received by 5:00 pm EST/EDST on the published Closing Date. NFPA 1963, Standard for Fire

More information

Essentials of Fire Fighting

Essentials of Fire Fighting Essentials of Fire Fighting 6 th Edition Certified Volunteer Firefighter Chapter 16 Fire Streams Learning Objectives Explain the way vaporization and steam relate to the extinguishing properties of water.

More information

REAR MOUNT AERIAL LADDER USED AS A WATER TOWER

REAR MOUNT AERIAL LADDER USED AS A WATER TOWER EVOLUTION 21A January 1, 1997 REAR MOUNT AERIAL LADDER USED AS A WATER TOWER 1. EQUIPMENT: 2. COMMAND: 1 Rear Mount Aerial Ladder 1 Portable Ladder Pipe (Note B) 1 Halyard and Reel (Note C) 1 Siamese 3"

More information

ESCONDIDO FIRE DEPT TRAINING MANUAL Section DRIVER OPERATOR Page 1 of Sutphen Aerial Operations Revised

ESCONDIDO FIRE DEPT TRAINING MANUAL Section DRIVER OPERATOR Page 1 of Sutphen Aerial Operations Revised DRIVER OPERATOR Page 1 of 12 2014 Sutphen Aerial Operations Revised 12-11-17 PROCEDURES FOR ELEVATING THE PLATFORM Placing the aerial platform into service requires qualified personnel trained in the proper

More information

MUELLER. Centurion Series Fire Hydrant. Centurion Super Centurion 200 Super Centurion 250. Reliable Connections. Background and Forward 2

MUELLER. Centurion Series Fire Hydrant. Centurion Super Centurion 200 Super Centurion 250. Reliable Connections. Background and Forward 2 operating Instructions manual MUELLER table of contents PAGE Background and Forward 2 Centurion Series Fire Hydrant Centurion Super Centurion 200 Super Centurion 250 Handling and Inspection 3 Installation

More information

HIGH-SPEED TIRE (TUBELESS TIRE)

HIGH-SPEED TIRE (TUBELESS TIRE) 20 HIGH-SPEED TIRE (TUBELESS TIRE) HIGH-SPEED TIRE CONSTRUCTION & FEATURES ------------ 20-2 HIGH-SPEED TIRE MAINTENANCE PRECAUTIONS ----------- 20-4 HIGH-SPEED TIRE REMOVAL/INSTALLATION ----------------

More information

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Truck Module Page 1 of 7 Ladder Introduction Revised

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Truck Module Page 1 of 7 Ladder Introduction Revised Truck Module Page 1 of 7 LADDER INTRODUCTION Introduction The three major objectives of fire ground operations are Rescue, Fire Control, and Property Conservation. In order to obtain these objectives,

More information

SECTION 4 - FUEL SYSTEMS AND CARBURETION

SECTION 4 - FUEL SYSTEMS AND CARBURETION SECTION - FUEL SYSTEMS AND CARBURETION FUEL SYSTEMS - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -62 FUEL PUMP - - - - - - -

More information

OPERATION AND MAINTENANCE MANUAL 5-1/4 AMERICAN-DARLING B-62-B-5 FIRE HYDRANT

OPERATION AND MAINTENANCE MANUAL 5-1/4 AMERICAN-DARLING B-62-B-5 FIRE HYDRANT OPERATION AND MAINTENANCE MANUAL 5-1/4 AMERICAN-DARLING B-62-B-5 FIRE HYDRANT INDEX 5-1/4 AMERICAN-DARLING B-62-B-5 FIRE HYDRANT OPERATION AND MAINTENANCE MANUAL OPERATION AND MAINTENANCE REPAIRS Operation

More information

MUELLER. Super Centurion 350 Fire Hydrant. Reliable Connections. Inspection and Maintenance 2. Filling Oil Reservoir 3. Facing the Hydrant 4

MUELLER. Super Centurion 350 Fire Hydrant. Reliable Connections. Inspection and Maintenance 2. Filling Oil Reservoir 3. Facing the Hydrant 4 operating Instructions manual MUELLER Super Centurion 350 Fire Hydrant table of contents PAGE Inspection and Maintenance 2 Filling Oil Reservoir 3 Facing the Hydrant 4 Restoring Service after Traffic Knockover

More information

TRAINING BULLETIN TOOLS 7 December, 1978 HOSE NOZZLES (HAND HELD) 1. NOZZLE NOMENCLATURE AND IDENTIFICATION

TRAINING BULLETIN TOOLS 7 December, 1978 HOSE NOZZLES (HAND HELD) 1. NOZZLE NOMENCLATURE AND IDENTIFICATION TRAINING BULLETIN TOOLS 7 December, 1978 1. NOZZLE NOMENCLATURE AND IDENTIFICATION 1.1 A nozzle identification and nomenclature system is established to insure that issuance and recall of equipment as

More information

Sentinel 250 Fire Hydrant

Sentinel 250 Fire Hydrant Maintenance Instructions manual table of contents PAGE Sentinel 250 Fire Hydrant Inspection and Lubrication 2 Rotating Hydrant to Face Desired Direction 3 Installing Extension Section 3-6 Restoring Service

More information

Rural Water Supply Operations Seminar & Drill

Rural Water Supply Operations Seminar & Drill Colton, New York Rural Water Supply Operations Seminar & Drill 75-min Tanker Shuttle Drill August 24, 2008 Summary Report Overview In August of 2008 the Colton Fire District, in conjunction with the Pierrepont

More information

ESCONDIDO FIRE DEPT TRAINING MANUAL Section DRIVER OPERATOR Page 1 of Sutphen Aerial Operations Revised

ESCONDIDO FIRE DEPT TRAINING MANUAL Section DRIVER OPERATOR Page 1 of Sutphen Aerial Operations Revised DRIVER OPERATOR Page 1 of 10 1997 Sutphen Aerial Operations Revised 12-11-17 PROCEDURES FOR ELEVATING THE PLATFORM Placing the aerial platform into service requires qualified personnel trained in the proper

More information

HexPro Series Low Profile Wrenches

HexPro Series Low Profile Wrenches HexPro Series Low Profile Wrenches Operation and Maintenance Manual Model 2HP 4HP 8HP 14HP 30HP www.torquetoolsinc.com Use the HEXPRO Series Low Profile Wrenches Model 2HP 4HP 8HP 14HP 30HP to install

More information

Low Profile Wrenches Operation and Maintenance Manual

Low Profile Wrenches Operation and Maintenance Manual Low Profile Wrenches Operation and Maintenance Manual http://www.torquetoolsinc.com Use the HEXPRO Series Low Profile Wrenches Model 2HP 4HP 8HP 14HP 30HP to install and remove large bolts that have minimal

More information

INSTALLATION TROUBLESHOOTING SUPPLEMENT

INSTALLATION TROUBLESHOOTING SUPPLEMENT TITAN Fuel Tanks INSTALLATION TROUBLESHOOTING SUPPLEMENT For Midship Replacement Fuel Tanks AND Utility Tanks This supplement is intended to provide additional information for installers to aid in simple

More information

NFPA STANDARDS DEVELOPMENT SITE

NFPA STANDARDS DEVELOPMENT SITE 1 of 42 9/27/2017, 1:14 PM NFPA STANDARDS DEVELOPMENT SITE Released Version Closing Date: September 07, 2017 NOTE: All Public Comment must be received NFPA 1963, Standard for Fire Hose Connections, 2014

More information

Engine Company Operations

Engine Company Operations Engine Company Operations Rule 1 There are 20 basic rules that we consider in Engine company operations: Rule 1- Select the source of water supply that is sufficient for the job intended, the nearest hydrant

More information

A /F/X Body Instruction Packet Rear Disc Conversion

A /F/X Body Instruction Packet Rear Disc Conversion A /F/X Body Instruction Packet Rear Disc Conversion 64-72 A Body / 67-81 F Body / 62-74 X Body This kit is for axles with a 3 1/8 spread center to center on the top two bolt holes (pictured left). Rotor

More information

BEFORE BEGINNING INSTALLATION

BEFORE BEGINNING INSTALLATION COMPLETE CHASSIS FUEL LINE KITS For 1996-2000 Honda Civic Equipped with B-Series Engine INSTALLATION INSTRUCTIONS PLEASE study these instructions carefully before beginning this installation. Most installations

More information

: 1250 gpm in the deck mode : 800 gpm while operating in the ground base - Dual Inlet : 1000 gpm while operating in the ground base - Single Inlet

: 1250 gpm in the deck mode : 800 gpm while operating in the ground base - Dual Inlet : 1000 gpm while operating in the ground base - Single Inlet APOLLO HI-RISER MONITOR STYLE 3433/3431 INSTALLATION, OPERATING, AND MAINTENANCE INSTRUCTIONS The following is intended to provide the basic instructions for installation, operation and maintenance of

More information

Eclipse GEN 2.0 CAFSystem, Model 150-ECL CAFS PTO Kit Installation Instructions

Eclipse GEN 2.0 CAFSystem, Model 150-ECL CAFS PTO Kit Installation Instructions Eclipse GEN 2.0 CAFSystem, Model 150-ECL CAFS PTO Kit Installation Instructions Read Read through the the safety installation information instructions overhaul carefully instructions before carefully beginning

More information

FIREFLO - MODEL F-06 INSPECTION, INSTALLATION & MAINTENANCE MANUAL. Item No.s/Description

FIREFLO - MODEL F-06 INSPECTION, INSTALLATION & MAINTENANCE MANUAL. Item No.s/Description FIREFLO - MODEL F-06 INSPECTION, INSTALLATION & MAINTENANCE MANUAL Item No.s/Description Item No. Description Material Specification HYDRANT Qty. Req d Item No. Description Material Specification 1 Operating

More information

(a) Remove the rear floor service hole cover. (b) Disconnect the fuel pump connector.

(a) Remove the rear floor service hole cover. (b) Disconnect the fuel pump connector. REMOVAL 1. REMOVE REAR SEAT CUSHION ASSEMBLY 2. REMOVE REAR FLOOR SERVICE HOLE COVER (a) Remove the rear floor service hole cover. (b) Disconnect the fuel pump connector. 3. DISCHARGE FUEL SYSTEM PRESSURE

More information

The following chart shows the NUS minimum stocking levels required for agency engines. Type Category Item Description NFES # 3, 4, & 5 6

The following chart shows the NUS minimum stocking levels required for agency engines. Type Category Item Description NFES # 3, 4, & 5 6 The following chart shows the NUS minimum stocking levels required for agency engines. Type Category Item Description NFES # 3, 4, & 5 6 Fire Tools & Equip Medical General Supplies McLeod 0296 1 Combination

More information

AMERICAN FLOW CONTROL 4 3/4 WATEROUS TREND FIRE HYDRANT

AMERICAN FLOW CONTROL 4 3/4 WATEROUS TREND FIRE HYDRANT AMERICAN FLOW CONTROL 4 3/4 WATEROUS TREND FIRE HYDRANT CONSTRUCTION Fully complies with ANSI/AWWA C502 and is available Listed by Underwriters Laboratories Inc. and Approved by FM Approvals in applicable

More information

RUFNEX Series Low Profile Wrenches Operation and Maintenance Manual

RUFNEX Series Low Profile Wrenches Operation and Maintenance Manual RUFNEX Series Low Profile Wrenches Operation and Maintenance Manual http://www.torsionx.com Use the RUFNEX Series Ultra-Low Profile Wrenches to install and remove large bolts that have minimal wrench clearance.

More information

Big Flow Systems. Major innovations in fire fighting and water transfer technology

Big Flow Systems. Major innovations in fire fighting and water transfer technology Big Flow Systems Major innovations in fire fighting and water transfer technology An integrated mobile high capacity foam and water delivery solution. Use as a comprehensive system or as individual components

More information

OPERATING INSTRUCTIONS & SERVICE MANUAL BLUE MAX II HYDROSTATIC TEST PUMP

OPERATING INSTRUCTIONS & SERVICE MANUAL BLUE MAX II HYDROSTATIC TEST PUMP PAGE 1 OF 10 OPERATING INSTRUCTIONS & SERVICE MANUAL BLUE MAX II HYDROSTATIC TEST PUMP EFFICIENT, EASY OPERATION Air operated pump Wide range of pressures and volumes Easy to operate controls Output pressure

More information

Ultra Elite Facepiece

Ultra Elite Facepiece Ultra Elite Facepiece MAINTENANCE AND REPAIR TAL 013 (L) Rev. 5 MSA 2010 Prnt. Spec. 10000005389 (I) Mat. 10042830 Doc. 10000015248 ULTRA ELITE FACEPIECE COMPONENTS Item Part No. Description 1 804804 Upper

More information

B Pump Mounting. Page 1 of 7

B Pump Mounting. Page 1 of 7 www.wildlandwarehouse.com P.O. Box 425 Blairstown, NJ 07825 Ph 1.866.WILDLAND Fx 908.362.6236 October 18, 2012 Specifications for our Standard 50, 75 or 100 gallon UTV Fire Suppression Skid Unit L Shaped

More information

OPERATION AND MAINTENANCE MANUAL

OPERATION AND MAINTENANCE MANUAL WREN IBT SERIES HYDRAULIC TORQUE WRENCHES IBT SQUARE DRIVE SERIES OPERATION AND MAINTENANCE MANUAL FOR WREN Products: POINT 75, 1IBT, 3IBT, 5IBT, 8IBT, 10IBT, 20IBT, 25IBT, 35IBT, 50IBT SQUARE DRIVE HYDRAULIC

More information

Operation and Maintenance. S100 Series Centrifugal Fire Pumps. Table of Contents. Visit us at F /22/02 6/21/18

Operation and Maintenance. S100 Series Centrifugal Fire Pumps. Table of Contents. Visit us at   F /22/02 6/21/18 S100 Series Centrifugal Fire Pumps Operation and Maintenance Form No. F-1031 Section 2117 Issue Date 02/22/02 Rev. Date 6/21/18 Table of Contents Safety Information-----------------------------------------------

More information

AMERICAN FLOW CONTROL 4 3/4 WATEROUS TREND FIRE HYDRANT

AMERICAN FLOW CONTROL 4 3/4 WATEROUS TREND FIRE HYDRANT AMERICAN FLOW CONTROL 4 3/4 WATEROUS TREND FIRE HYDRANT CONSTRUCTION Fully complies with ANSI/AWWA C502 and is available UL Listed and Approved by FM Approvals in applicable configurations. DUCTILE IRON

More information

DESCRIPTION & OPERATION

DESCRIPTION & OPERATION AIR BAG RESTRAINT SYSTEM 1996 ACCESSORIES/SAFETY EQUIPMENT Toyota Air Bag Restraint System DESCRIPTION & OPERATION WARNING: To avoid injury from accidental air bag deployment, read and carefully follow

More information

REBUILD KIT. Extend the Life of Your Dosatron. D14MZ2VFIIK Part #: MKD14MZ2K Kit includes:

REBUILD KIT. Extend the Life of Your Dosatron. D14MZ2VFIIK Part #: MKD14MZ2K Kit includes: Extend the Life of Your Dosatron REBUILD KIT 800-523-8499 727-443-5404 D14MZ2VFIIK Part #: MKD14MZ2K Kit includes: Part 1: Piston Kit Upper flange Lower flange Omega spring Connecting rod Push rod seal

More information

AKRON NEW YORKER MULTIVERSAL NOZZLE

AKRON NEW YORKER MULTIVERSAL NOZZLE TRAINING BULLETIN TOOLS 17 June, 1983 1. INTRODUCTION 1.1 This training bulletin is issued to govern the operation, use, and maintenance of the Akron New Yorker Multiversal Nozzle. 1.2 Information contained

More information

NSGV EVE-ER I, O, & M MANUAL

NSGV EVE-ER I, O, & M MANUAL TABLE OF CONTENTS Rail Layout.. Page 1 Support Placement...Page 1 Rail Assembly.Page 1 Rail Duct Connections.. Page 2 Rubber Lip Installation.. Page 3 Pneumatic End Stop. Page 4 End Stop. Page 4 End Cap..

More information

Alternator Removal and Installation Instructions

Alternator Removal and Installation Instructions Alternator Removal and Installation Instructions Removal CAUTION: Always use care when working on your vehicle! Do NOT disconnect any electrical cables or wiring while the engine is running! Make sure

More information

I-799/79V Coil Components

I-799/79V Coil Components WARNING Read and understand all instructions before attempting to install any Victaulic products. Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic

More information

Part 7 DO IT YOURSELF MAINTENANCE

Part 7 DO IT YOURSELF MAINTENANCE Part 7 DO IT YOURSELF MAINTENANCE Chapter 7 2 Engine and Chassis Checking the engine oil level Checking the engine coolant level Checking brake fluid Checking power steering fluid Checking tire pressure

More information

Maintenance Information

Maintenance Information 04581245 Edition 2 May 2014 Air Grinder, Die Grinder and Sander Series G2 (Angle) Maintenance Information Save These Instructions Product Safety Information WARNING Failure to observe the following warnings,

More information

TRAINING BULLETIN APPARATUS P-2 January 22, 1998 FLOWMETERS

TRAINING BULLETIN APPARATUS P-2 January 22, 1998 FLOWMETERS TRAINING BULLETIN APPARATUS P-2 January 22, 1998 FLOWMETERS 1. INTRODUCTION 1.1 The intention of this bulletin is to describe the operation and calibration of the SPAN FLOWMINDER, the flowmeter presently

More information

354 CHAPTER EIGHT WATER PUMP

354 CHAPTER EIGHT WATER PUMP 354 CHAPTER EIGHT 33 Shift handle F : Forward N : Neutral R : Reverse proper alignment of the water tube to the water pump opening during each installation attempt. Make sure the locating pins enter the

More information

Operation and Maintenance Manual http://www.torsionx.eu Use the MaxDrv Series Square Drive Torque Wrench Model.75, 1, 3, 5, 8, 10, 20, 25, 35, 50 to install and remove threaded fasteners requiring precise

More information

Fluid-O-Tech ROTOFLOW ROTARY VANE PUMP REBUILD MANUAL

Fluid-O-Tech ROTOFLOW ROTARY VANE PUMP REBUILD MANUAL Fluid-O-Tech PUMP TECHNOLOGY AT ITS BEST WWW.FLUID-O-TECH.COM Office: 161 Atwater St., Plantsville, CT 06479 Phone: (860) 276-9270 Fax: (860) 620-0193 ROTOFLOW ROTARY VANE PUMP REBUILD MANUAL 08/09 Ed.,

More information

55-64 Full Size GM (Impala, Bel Air, etc.) This kit is for axles with a 3 3/8 spread center to center on the top two bolt holes (pictured left).

55-64 Full Size GM (Impala, Bel Air, etc.) This kit is for axles with a 3 3/8 spread center to center on the top two bolt holes (pictured left). SUM-BK1624A Full Size GM Installation Instructions Rear Disc Conversion 55-64 Full Size GM (Impala, Bel Air, etc.) This kit is for axles with a 3 3/8 spread center to center on the top two bolt holes (pictured

More information

Routine Emergencies are defined as incidents that do not require the deployment of hoselines. Ex. Fire alarms, smell of smoke, etc..

Routine Emergencies are defined as incidents that do not require the deployment of hoselines. Ex. Fire alarms, smell of smoke, etc.. 15. Riding Assignments 15.1 Assignments 15.1.1 The following assignments have been developed to alleviate duplication of tasks on the fire scene. These assignments are only guides and can be changed on

More information

INSTALLATION AND MAINTENANCE OF TOP LOADING ARM

INSTALLATION AND MAINTENANCE OF TOP LOADING ARM INSTALLATION AND MAINTENANCE OF TOP LOADING ARM D TABLE OF CONTENTS 1. INTRODUCTION 04 2. SPECIFICATION OF THE REDLANDS LOADING ARM 04 3. INSTALLING THE LOADING ARM 3.1. Installation Procedures 05 4.

More information

1 Green Pressure Regulator Spring Automatic transmissions operate at temperatures between 150ºF and

1 Green Pressure Regulator Spring Automatic transmissions operate at temperatures between 150ºF and Installation Instructions for 603107 Valve Body Kit C-4 1970 & Later Tools Required Speed Handle or Ratchet 3/8 Drive 1/2 Socket 3/8 Drive 7/16 Socket 3/8 Drive 5/16 Socket 3/8 Drive Small Screwdriver

More information

CAUTIONS AND WARNINGS

CAUTIONS AND WARNINGS FIREWALL FORWARD FUEL LINE KITS For 1996-2000 Honda Civic Equipped with B-Series Engine INSTALLATION INSTRUCTIONS PLEASE study these instructions carefully before beginning this installation. Most installations

More information

1/2" AIR DRIVEN DIAPHRAGM PUMP

1/2 AIR DRIVEN DIAPHRAGM PUMP 1/2" DRIVEN DIAPHRAGM PUMP OPERATION AND SERVICE GUIDE O-1225D NOV. 2008 Page 1 of 6 Refer to Bulletin P-605, Parts List P-9151 DRIVEN, DOUBLE DIAPHRAGM PUMP MANUAL Congratulations on purchasing one of

More information

FAIRFAX COUNTY FIRE & RESCUE DEPARTMENT TRAINING BULLETIN. ISSUED BY: Captain I Daniel D. Shaw, Fire Station 409-C

FAIRFAX COUNTY FIRE & RESCUE DEPARTMENT TRAINING BULLETIN. ISSUED BY: Captain I Daniel D. Shaw, Fire Station 409-C FAIRFAX COUNTY FIRE & RESCUE DEPARTMENT TRAINING BULLETIN NUMBER: DATE: DISTRIBUTION: I ISSUED BY: Captain I Daniel D. Shaw, Fire Station 409-C APPROVED BY: SUBJECT: Nozzle Inspection The nozzle is a vital

More information

5 1 /4 PACER. It s AMERICAN What We Know. DARLING MARK 73 2 FIRE HYDRANT AMERICAN FLOW CONTROL WATEROUS FIRE HYDRANT

5 1 /4 PACER. It s AMERICAN What We Know. DARLING MARK 73 2 FIRE HYDRANT AMERICAN FLOW CONTROL WATEROUS FIRE HYDRANT WATEROUS FIRE HYDRANT DUCTILE IRON 250 P.S.I.G. WATEROUS FIRE HYDRANT AMERICAN FLOW CONTROL It s AMERICAN What We Know. DARLING MARK 73 2 FIRE HYDRANT CONSTRUCTION WATEROUS FIRE HYDRANT TWO PIECE OPERATING

More information

Innovative Firefighting Products

Innovative Firefighting Products Innovative Firefighting Products TFT Offers Flow Efficient Water Supply and Innovative Appliance Solutions to Responders Worldwide Flow efficiency, a lightweight compact design, and long-term corrosion

More information

SOUTH DAKOTA FIREFIGHTERS ASSOCIATION OFFICIAL EVOLUTION RULES

SOUTH DAKOTA FIREFIGHTERS ASSOCIATION OFFICIAL EVOLUTION RULES SOUTH DAKOTA FIREFIGHTERS ASSOCIATION OFFICIAL EVOLUTION RULES REVISED: April 2017 SOUTH DAKOTA FIREFIGHTERS ASSOCIATION FIRE SCHOOL EVOLUTION RULES EVOLUTION COMMITTEE There will be an Eolution Committee

More information

DuraMAC LIGHT COMMERCIAL & IRRIGATION WATER PRESSURE BOOSTER SYSTEM INSTALLATION INSTRUCTIONS

DuraMAC LIGHT COMMERCIAL & IRRIGATION WATER PRESSURE BOOSTER SYSTEM INSTALLATION INSTRUCTIONS DuraMAC LIGHT COMMERCIAL & IRRIGATION WATER PRESSURE BOOSTER SYSTEM INSTALLATION INSTRUCTIONS The DuraMAC TM Water Pressure Booster System is the first booster pump of its kind to be designed for virtually

More information

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL PIPE WORK. This work covers part of outcome 2 of the Edexcel standard module:

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL PIPE WORK. This work covers part of outcome 2 of the Edexcel standard module: FLUID POWER FLUID POWER EQUIPMENT TUTORIAL PIPE WORK This work covers part of outcome 2 of the Edexcel standard module: UNIT 21746P APPLIED PNEUMATICS AND HYDRAULICS The material needed for outcome 2 is

More information

CARTRIDGE FILTER SYSTEMS OWNER S MANUAL

CARTRIDGE FILTER SYSTEMS OWNER S MANUAL CARTRIDGE FILTER SYSTEMS OWNER S MANUAL Installation Operation Parts Designed, Engineered & Manufactured in the USA. 2017 Waterway Plastics 2200 East Sturgis Road, Oxnard CA 93030 Phone 805.981.0262 Fax

More information

Operation and Maintenance Manual Model.75,, 3, 5, 8, 0, 0, 5, 35, 50 http://www.torsionx.com Use the MaxDrv Series Square Drive Torque Wrench Model.75,, 3, 5, 8, 0, 0, 5, 35, 50 to install and remove threaded

More information

IBT Series Square Drive Torque Wrenches

IBT Series Square Drive Torque Wrenches IBT Series Square Drive Torque Wrenches Operation and Maintenance Manual Model.75, 1, 3, 5, 8, 10, 20, 25, 35, 50 http://www.torsionx.com Use the IBT Series Square Drive Torque Wrenches Model.75, 1, 3,

More information

Table Summary of Sprinkler System Inspection, Testing, and Maintenance. Reference. Inspection , ,

Table Summary of Sprinkler System Inspection, Testing, and Maintenance. Reference. Inspection , , Table 5.1.1.2 Summary of Sprinkler System Inspection, Testing, and Maintenance Item Frequency Reference Inspection Gauges (dry, preaction, and deluge systems) Quarterly 5.2.4.2, 5.2.4.3, 5.2.4.4 Control

More information

Eclipse GEN 2.0 CAFSystem, Model 150-ESECL as used with TC20 Series PTO Installation Instructions

Eclipse GEN 2.0 CAFSystem, Model 150-ESECL as used with TC20 Series PTO Installation Instructions Eclipse GEN 2.0 CAFSystem, Model 150-ESECL as used with TC20 Series PTO Installation Instructions Read Read through the the safety installation information instructions overhaul carefully instructions

More information

OPERATION AND MAINTENANCE MANUAL 5-1/4 AMERICAN-DARLING B-84-B-5 FIRE HYDRANT

OPERATION AND MAINTENANCE MANUAL 5-1/4 AMERICAN-DARLING B-84-B-5 FIRE HYDRANT OPERATION AND MAINTENANCE MANUAL 5-1/4 AMERICAN-DARLING B-84-B-5 FIRE HYDRANT INDEX 5-1/4 AMERICAN-DARLING B-84-B-5 FIRE HYDRANT OPERATION AND MAINTENANCE MANUAL OPERATION AND MAINTENANCE REPAIRS Operation

More information

OPERATION MANUAL NT50 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 7/11 rev. 1

OPERATION MANUAL NT50 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 7/11 rev. 1 OPERATION MANUAL NT50 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS A JDA Global Company 7/11 rev. 1 CAUTION SAFETY POINTS TEMPERATURE LIMITS: Neoprene -17.8 C to 93.3 C 0 F to 200 F Buna-N -12.2

More information

Albemarle County Virginia Brush Fire Truck Specification

Albemarle County Virginia Brush Fire Truck Specification Albemarle County Virginia Brush Fire Truck Specification Purpose: This specification is intended to be used for the procurement of Brush Fire Suppression Apparatus for the Fire Departments & Companies

More information

As a safety precaution, remove keys from the ignition while working under or around the vehicle.

As a safety precaution, remove keys from the ignition while working under or around the vehicle. CAB AND CHASSIS As a safety precaution, remove keys from the ignition while working under or around the vehicle. 1. Approach Check the overall appearance of vehicle stance (not leaning). Check for signs

More information

***Please follow instructions for ease of installation and correct fit.***

***Please follow instructions for ease of installation and correct fit.*** RAMPAGE P R O D U C T S Installation Instructions Part number 1094XX Frameless Soft Top for Jeep Wrangler YJ 1992-1995 with Half Doors NOTE: Installation of the top in warm weather is optimal for ease

More information

OPERATIONS / TRAINING

OPERATIONS / TRAINING TRAINING - POLICY INDEX OPERATIONS / TRAINING O/TRG-201 USE OF TRAINING FACILITIES... 1 O/TRG-202 LOANING OF EQUIPMENT AND TRAINING MATERIALS... 2 O/TRG-203 FIRE-POLICE GYMNASIUM UTILIZATION... 2 O/TRG-204

More information

Handline Nozzles. Foam Tubes In Line eductors & Piercing Nozzle. Forestry Products. Firehouse cleaning Products

Handline Nozzles. Foam Tubes In Line eductors & Piercing Nozzle. Forestry Products. Firehouse cleaning Products Fourth Edition Table of Contents Handline Nozzles Foam Tubes In Line eductors & Piercing Nozzle Playpipes & Shutoffs Smooth Bore Tips & Repair kits Forestry Products Monitors DELUGE Tips Master Stream

More information

DYNAFLUID 2000 STEAM & WATER MIXING VALVE INSTALLATION & OPERATING MANUAL

DYNAFLUID 2000 STEAM & WATER MIXING VALVE INSTALLATION & OPERATING MANUAL DYNAFLUID 2000 STEAM & WATER MIXING VALVE INSTALLATION & OPERATING MANUAL LILLY ENGINEERING COMPANY 217 CATALPA STREET P.O. BOX 173 ITASCA, ILLINOIS 60143 630-773-2222 FAX: 630-773-3443 www.lillyengineering.com

More information

FIRE HOSE NOZZLES & WRENCHES

FIRE HOSE NOZZLES & WRENCHES FIRE HOSE NOZZLES & WRENCHES See Valve Section for Fire Hydrant & Forestry Valves Part Thread PRICE Number Size EACH G97B BRASS FOG NOZZLE We sell a variety of fire hose coupling wrenches to suit various

More information

SYSTEM SAVER 318 AIR COMPRESSOR FOR MACK E-TECH AND ASET ENGINES MAINTENANCE MANUAL

SYSTEM SAVER 318 AIR COMPRESSOR FOR MACK E-TECH AND ASET ENGINES MAINTENANCE MANUAL SYSTEM SAVER 318 AIR COMPRESSOR FOR MACK E-TECH AND ASET ENGINES MAINTENANCE MANUAL NON-THROUGH DRIVE THROUGH DRIVE Service Notes About This Manual This manual provides service and repair procedures for

More information

MAINTENANCE MANUAL DI 16

MAINTENANCE MANUAL DI 16 MAINTENANCE MANUAL DI 16 0.2-1.6% Press Ctrl + L for full screen 1 STANDARD INSTALLATION Inlet Outlet Optional accessories: Pressure regulator Solenoid valves Water meter Flow restrictor 200 Mesh/ 80 micron

More information

ERGONOMICS ANALYSIS Job Safety Analysis

ERGONOMICS ANALYSIS Job Safety Analysis ERGONOMICS ANALYSIS Job Safety Analysis Step 1 PROVIDE BACKGROUND Job/Task: Manual Water Supply Hose Lay Date: mm/dd/ccyy Analyzed by: Safety Consultant Location: Mosquito Heights Project Number: 01-10

More information

OPERATION MANUAL. ALUMINUM Models. 316 S.S. Models NTG25 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 1/14 rev.

OPERATION MANUAL. ALUMINUM Models. 316 S.S. Models NTG25 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 1/14 rev. OPERATION MANUAL NTG25 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS ALUMINUM Models 316 S.S. Models A JDA Global Company 1/14 rev. 3 CAUTION SAFETY POINTS TEMPERATURE LIMITS: Neoprene -17.8 C to

More information