1 ENGINE MODULE Page 1 of 12 SPECIAL HOSE OPERATIONS The information presented in this section covers a variety of hose-handling methods. These special operations include: Connecting hoses to fire department connections Operating from a standpipe Extending a hose-line Advancing a hose-line up stairs Hoisting a hose-line aloft Advancing a hose-line up a ladder Fire Department Connections (FDC) Many of today s buildings, complexes, and facilities are built with some form of private fire protection system. The most commonly encountered by firefighters are automatic sprinkler systems and standpipes. FDCs may supply sprinkler only, standpipe only or a combination that supplies both; all are considered a fire protection system. When a fire occurs in a building with a fire protection system, an engine company is assigned to connect to the FDC to support the system. In Escondido Engineers are taught to set their discharge pressure to 100 PSI for no smoke showing and 150 PSI for smoke showing or a confirmed fire. In combination systems, the Engineer will pump to the attack line at the pressure required. FDC s can be found on the side of buildings or in a driveway. By code they are situated to provide easy access to the fire department and are required to have a fire hydrant within 50 ft. Access to connections must be clear, unobstructed and maintained. The connection itself must be serviced by a State certified contractor every five years and inspected by the fire department during the Life Safety Inspection. Hose connections to the fire department connection are 2½ female swivels with either a threaded cap or non-threaded break away cover. Some buildings are large enough to require separate sprinkler zones and in some cases there may be multiple FDC s supplying the different
2 ENGINE MODULE Page 2 of 12 zones. Such is the case with the downtown Palomar building and Westfield North County Mall. When multiple FDC s are required they must have a sign indicating what it covers. All FDC s are located on our pre-maps. Firefighters should always use both 2½ connections. Using both allows for volume of water that may be required and a backup if one line is compromised. It is not uncommon for the caps to be difficult to remove usually do to corrosion and lack of maintenance. The firefighter should bring a spanner wrench to assist with difficult caps. Non-threaded caps are designed with weak points in the cap (break away caps) to break when struck with a hard object. A spanner wrench or other hardened tool can be used for this. Once the caps are off, the firefighter must look for and clear any debris that may be inside the connection. Internally, connections are made with a clapper valve that closes the open side when the other is charged. Once both connections are made, the clapper moves to the middle so both lines can flow. This means that once one line is connected it can be charged without water escaping the unused inlet. Standpipe Operations One of the greatest problems in fighting fires in large buildings, particularly in multi- storied buildings, is transporting water to the seat of the fire. Years ago, firefighters were required to lay hose into a building and up stairwells to reach the fire floor. Eventually, however, new buildings were equipped with standpipe systems so that firefighters only need to transport enough hose to connect to the standpipe and reach the fire. These standpipe systems may be vertical, such as in high-rise buildings, or horizontal like ones found in shopping malls and warehouses.
3 ENGINE MODULE Page 3 of 12 Standpipe systems, whether wet or dry, are an important component to firefighting efforts in large buildings. Firefighters must be familiar with their operation and arrangement. Buildings constructed with standpipes will have a minimum of one 2½ male connection with a protective cap. Connections are located at each floor of a multi-story building and are usually located in the stairwells. Connections will either be exposed or installed in a cabinet. Although transporting hose to a standpipe connection is a more efficient than laying hose the entire distance from the apparatus to the fire, it can still be an exhausting job. Firefighters must follow established techniques to operate safely and effectively when connecting hose lines to a standpipe system. The following guidelines should be considered when operating from a standpipe: Where full protective clothing and SCBA. Shoulder load 2½ hose or carry hose bundles for use as attack lines. Connect a 2½ section of hose to standpipe when operating with hose bundles. Firefighters must take forcible entry tools, spanner wrenches, and adapters. Connect to the standpipe one floor below the fire floor. Remove protective cap from standpipe and check for debris. Lay hose to the outside of the stairwell to prevent kinks and minimize obstruction. Flake excess hose up stairs toward the floor above the fire floor. Fully open valve when charging the hose line. The decision to use a standpipe is the Captain s or the Division Supervisor s when established. Note to Engineers: In combination systems supplying sprinklers and a standpipe, Engineer s must pump to the standpipe and the attack lines from it rather than the sprinkler system. With sprinkler only systems our engine pressure is 100 PSI No Smoke Showing and 150 PSI for Smoke Showing or a Known Fire.
4 ENGINE MODULE Page 4 of 12 One factor that goes into whether to use a standpipe is if the standpipe has been properly maintained. The integrity of the system isn t always well known but previous site visits and Life Safety Inspections can help. Some systems are not part of a business and may be part of a multiple story residential building. Systems in residential units are more susceptible to tampering by occupants. Another factor in standpipe operations is whether there is a more efficient way to get hose to the fire scene. For instance, even though the fire building may be multi-story and have standpipes the fire area may be on the first floor and a pre-connect or 2 ½ to bundles is a better choice. Even though a building may have standpipes it may make more sense to access the balcony of an adjoining unit and make access through that unit and the interior hallway to the fire apartment. The Captain using the pre-maps and dispatch information will be selecting the best method to place the attack lines. The firefighter must be proficient in any order that Captain may give to reach the fire since the method is situation dependent. 2½ to Standpipe Large fires may require 2½ flows with either a combination or smooth bore nozzle. The default 2½ smooth bore tip size is 1. Any change of tip size must be communicated to the Engineer. Engineers will pump to the line plus friction loss added for the standpipe system. In this case the firefighter will usually get an assignment that includes 150 ft. or more of 2½ hose. Shoulder loaded hose by multiple firefighters may be required to move the hose up the stairs to the standpipe outlet and advanced after the connection. As a variation to the shoulder load method in Engine Module Section Attack Hose Lays the hose is connected directly to the standpipe instead of to the engine. 2½ to Bundles from Standpipe More often, the standpipe is used to supply 1¾ hose bundles. When bundles are used a section of 2½ is used to connect to the standpipe outlet. This sections serves to give room for the 2 ½ to 1½ gated wye to be connected and can add needed length to the hose pull. The default 2½ hose utilized for this is one 50 ft. section. The Captain can adjust this as needed by either adding more 2 ½ for example 100 ft. or may use a 20 ft. bypass section if additional hose length isn t required. Extending A Hose line There are times when hose lines that have been deployed on the fire ground are required to be extended. These hose lines can be extended with hose of the same size or smaller diameter. This is one reason we use break away nozzles. See Engine Module section for more information on the breakaway feature of our nozzles.
5 ENGINE MODULE Page 5 of 12 Sometimes, for example, an existing 2½ attack line may be extended by attaching a 2½ x 1½ gated wye, allowing firefighters to attach two smaller diameter attack lines, usually hose bundles. No matter the situation, firefighters must consider what type of hose line and nozzle are in use and gather the required appliances and hose needed to complete the assigned task. Firefighters are faced with many different methods of extending a hose line based upon the fire equipment, including nozzle types available to complete the evolution. Firefighters must be familiar with the fire equipment available to them so that this operation can be completed safely and efficiently. Unless using the breakaway feature of the nozzle the water flow must be shut down so the hose line can be extended. Firefighters have the following prioritized options when shutting down the existing hose line: If equipped with a breakaway nozzle, use bale shutoff and remove nozzle. The nozzle portion has an offsetting. Have apparatus operator shut down hose line. Use a hose clamp currently we do not carry hose clamps. The following guidelines should be considered when extending hose lines: Consider type of nozzle and size of hose line already in use. Ensure apparatus operator is aware of assignment affecting existing hose line. Only gather necessary equipment (i.e. hose, nozzles, adapters). After connections are made safely set aside any unused equipment. Flake out hose prior to charging the extended hose line.
6 ENGINE MODULE Page 6 of 12 Stairwells In any stairwell space is limited and kinks always need to be monitored. Attention must also be given to maintaining the integrity of the stairwell as a ventilation conduit. An attack stairwell should be designated. Occupants should be directed to other stairwells when possible or to shelter in place when safe to do so. Commercial stairwells can service floors 14 ft. or more apart. These stairwells can require a full 50 ft. section of hose to make the stairwell travel distance. Residential stairwells used in apartment buildings are usually smaller with approximately 8-10 ft. between floors. Extra hose staged in the stairwell when safe should be placed on the stairs above the point of entry to facilitate movement of the hose onto the fire floor. If not safe to do so, the hose may be advanced from the stairs below but must be laid out in such a way to minimize kinks and trip hazards. Advancing Hose Up Stairs Hose is difficult to drag and advance in an open space and is exceedingly difficult to drag up stairs and around the obstructions found in a stairwell. When safety permits, hose should be advanced up stairways before it is charged with water. If the line has already been charged, additional firefighters will be needed to advance the hose line up the stairwell. When advancing hose up stairs, the hose shall be laid against the outside wall of the stairwell to avoid sharp bends and kinks and to give a path of travel for firefighters. Hanging Method The hanging method uses the space between the stair run and railing. When used the hose hangs in this space vertically from the point of entry to the floor being used, normally the fire floor. The hanging method requires about ½ the hose that laying the hose on the stairs requires. The space in between the stair run and railing must be wide enough for the hose to fully expand when charged. If that space is not large enough or doesn t exist, the hose must be laid on the stairs. Always bring enough hose to lay on the stairs if not sure if the hanging method is an option.
7 ENGINE MODULE Page 7 of 12 Order of Operations Hanging Method Advance hose to the base of the stairs Grab the male or nozzle end of the hose and proceed up the stairs holding the end in your right hand so the hose is pulled up the well. When possible the nozzle/hose should be passed through the railing as low as possible to minimize kinks and provide a cleaner work area. If not possible to pass the hose low on the railing it must come over the top. D Pull all excess hose up and shoulder load it. The hose is then secured with a hose strap so its weight doesn t pull it back down.
8 ENGINE MODULE Page 8 of 12 Excess hose should be flaked above the fire floor because it will be much easier to advance when the hose line is carried onto the fire floor. Hoisting A Hose line Hose can also be hoisted up the outside of a building with a rope. Only uncharged hose lines should be hoisted in this fashion. Hose should be advanced to a position below the objective. Once the hose is positioned on the ground, the firefighter on the floor above lowers the end of a rope or carabineer from a drop bag (see below). When possible, edge protection should be provided to prevent damage to the hose. Firefighters should pull aloft as much hose as needed prior to charging the hose line. The hose line should be secured to the building or ladder when possible. Order of Operations Hoisting a Hose Line Prepare hose for hoisting aloft. Pull adequate hose to hoisting location. Flake hose out in a neat arrangement in an effort to avoid snags during hoisting. Tie off hose. Fold hose back over itself locating nozzle approximately 6 feet from fold. Assure bale is closed and place between nozzle and hose. Coworker drops utility rope from area above. Tie a clove hitch-up on the nozzle and hose, and then tie a half hitch halfway between nozzle and folded end. Tie a half hitch approximately 6-8 inches from folded end. Hoist hose aloft. Firefighter on ground guides hose upward by holding hose line. Do not stand directly below hoisting operation.
9 ENGINE MODULE Page 9 of 12 Secure hose. Tie hose off to building, as required. Drop Bag Hose Aloft Escondido utilizes drop bags that carry approximately 90 ft. of ¼ nylon rope. These drop bags are attached to the waist band of every breathing apparatus. Drop bags have many potential uses. Tying hose and equipment to go aloft is one of the main uses. One end of the rope is secured with a carabineer to the interior of the bag and the other end is tied into a figure eight knot with another carabineer attached to the figure eight When used to hoist hose it is recommended the firefighter keeps the bag attached to the waist band of the BA and lower the end with the carabineer attached to the figure eight to the hose to be raised. Once the equipment is raised, the rope is disconnected, the rope collected/wrapped around the firefighter s hand and replaced into the bag for future use. Order of Operations - Utilizing drop bag for taking hose or other equipment aloft Carabineer (preferred) 1. Create a bite of rope and pass it through the carabineer.
10 ENGINE MODULE Page 10 of Slip the bite over the end of the nozzle 3. Once raised dis-connect the rope from the hose - The firefighter then wraps the rope around his hand and stuffs it back into the bag. Order of Operations - Utilizing drop bag for taking hose or other equipment aloft middle of the rope 1. Make a figure 8 knot Loop must be large enough to slip over the nozzle.
11 ENGINE MODULE Page 11 of Slip loop through bail and over nozzle 3. Hoist hose Advancing Hose Up A Ladder The safest way to get hose to an elevated position is to carry it up stairs or by hoisting the hose line aloft utilizing a rope. However, sometimes these methods cannot be used, and it is necessary to advance the hose up a ladder. Advancing hose up a ladder should be done only with an uncharged hose line. If the hose line has been charged with water, it is safer, quicker, and easier to drain the hose and relieve the pressure before advancing. Once the ladder is in place and hose line has been pulled, a firefighter should position at the base of the ladder so that the hose can be safely guided up as the firefighter climbs. The best way to advance the hose line up the ladder is to have the firefighter drape the nozzle over the shoulder, from front to back, across your chest with the nozzle resting against your back. When taking sections of hose up the aerial or fully extended 35 sometimes it is helpful for two or three firefighters to assist. When this is the case, the first firefighter with the nozzle climbs up the ladder until the first fly section is reached and waits until the next
12 ENGINE MODULE Page 12 of 12 firefighter is ready to proceed. At this point, a second firefighter drapes a large loop of hose over the shoulder, same side as first firefighter, and starts climbing the ladder. A third firefighter may be used in the same manner as needed. When firefighters have reached their objective the hose line and excess hose should be pulled aloft and arranged for fire attack. If the objective is away from the top of the ladder the firefighter should shoulder load the hose to facilitate advancing the hose. Once the hose has been pulled up and placed on shoulder, the hose will need to be secured to the building with webbing so its own weight doesn t pull it back down as the firefighter advances or when it gets charged. Firefighters do not need to lock into the ladder when positioned momentarily for the purpose of placing the nozzle or hose line from the ladder to the building. However, a firefighter must lock into the ladder if he will be required to maintain his position for an extended period of time. The following guidelines should be considered when advancing a hose line up a ladder: Secure hose to building whenever possible. Do not secure hose to ladder when working on roof, landing, or balcony. Pass hose/nozzle through lower railings when possible. Avoid charging hose line and operating nozzle from ladder.
ESCONDIDO FIRE DEPARTMENT TRAINING MANUAL ENGINE MODULE HOSE PAGE 1 OF 20 Supply Hose Lays Revised
HOSE 12-01-16 PAGE 1 OF 20 There are five base North Zone supply hose lays: Forward Lay Spotting a Hydrant Stationary Lay Reverse Lay Split Lay Escondido Fire Department Core Hose Lays The Escondido Fire
More informationESCONDIDO FIRE DEPT TRAINING MANUAL Section DRIVER OPERATOR Page 1 of Sutphen Aerial Operations Revised
DRIVER OPERATOR Page 1 of 12 2014 Sutphen Aerial Operations Revised 12-11-17 PROCEDURES FOR ELEVATING THE PLATFORM Placing the aerial platform into service requires qualified personnel trained in the proper
More informationChapter 15. Fire Hose. Answer Key. Firefighter I
Chapter 15 Fire Hose Firefighter I Terms 1. Fire Hose A flexible, portable tube manufactured from water tight materials in 50 to 100 foot (15 to 30 m) lengths that is used to transport water from a source
More informationINSTRUCT-O-GRAM HOSE OPERATIONS THE HANDS ON TRAINING GUIDE FOR THE FIRE INSTRUCTOR VOLUME XI, ISSUE 9 HOSE OPERATIONS SEPTEMBER 1990 INSTRUCTOR TASK
INSTRUCT-O-GRAM THE HANDS ON TRAINING GUIDE FOR THE FIRE INSTRUCTOR VOLUME XI, ISSUE 9 HOSE OPERATIONS SEPTEMBER 1990 HOSE OPERATIONS INSTRUCTOR TASK To use hose lines within a structure to attack fire,
More informationESCONDIDO FIRE DEPT TRAINING MANUAL Section DRIVER OPERATOR Page 1 of Sutphen Aerial Operations Revised
DRIVER OPERATOR Page 1 of 10 1997 Sutphen Aerial Operations Revised 12-11-17 PROCEDURES FOR ELEVATING THE PLATFORM Placing the aerial platform into service requires qualified personnel trained in the proper
More informationTRAINING AND EQUIPMENT MANUAL 304 LADDER PRACTICES GROUND LADDERS EFFECTIVE: OCTOBER 2007
TRAINING AND EQUIPMENT MANUAL 304 LADDER PRACTICES 304.004 GROUND LADDERS EFFECTIVE: OCTOBER 2007 Ground ladders are one of the primary tools used by firefighters. They are versatile and durable, easy
More informationEssentials of Fire Fighting,
Essentials of Fire Fighting, 5 th Edition Chapter 13 Fire Hose Chapter 13 Lesson Goal After completing this lesson, the student shall be able to use, care for, and perform maintenance on fire hose, couplings,
More informationEngine Company Operations
Engine Company Operations Rule 1 There are 20 basic rules that we consider in Engine company operations: Rule 1- Select the source of water supply that is sufficient for the job intended, the nearest hydrant
More informationESCONDIDO FIRE DEPT TRAINING MANUAL Section Truck Module Page 1 of 7 Ladder Introduction Revised
Truck Module Page 1 of 7 LADDER INTRODUCTION Introduction The three major objectives of fire ground operations are Rescue, Fire Control, and Property Conservation. In order to obtain these objectives,
More informationTWO FULLY EQUIPPED PUMPERS STATIC AND PRESSURIZED WATER SOURCES REFERENCES: ESSENTIALS OF FIRE FIGHTING, FOURTH EDITION, IFSTA, CHAPTERS 11 AND 12
INSTRUCTOR GUIDE TOPIC: BACK TO BASICS: ESTABLISHING SUPPLY LINES TIME REQUIRED: THREE HOURS MATERIALS: TWO FULLY EQUIPPED PUMPERS STATIC AND PRESSURIZED WATER SOURCES REFERENCES: ESSENTIALS OF FIRE FIGHTING,
More informationESCONDIDO FIRE DEPARTMENT TRAINING MANUAL DRIVER OPERATOR PUMPING PAGE 1 OF 6 Nozzles & Hose Revised
PUMPING 06-30-17 PAGE 1 OF 6 TFT Task Force Tip Combination Nozzles There are two sizes of hand line nozzles, 1 ½ and 2 ½. Our 1 ½ nozzles are Task Force Tip (TFT) combination nozzles. They are primarily
More informationENGINE COMPANY OPERATIONS AND ASSIGNMENTS
SOG 1-3 ENGINE COMPANY OPERATIONS AND ASSIGNMENTS A. Scope: This operational guideline shall be utilized for Engine Company Operations. Firefighters must possess the skills required to fulfill their designated
More informationAKRON NEW YORKER MULTIVERSAL NOZZLE
TRAINING BULLETIN TOOLS 17 June, 1983 1. INTRODUCTION 1.1 This training bulletin is issued to govern the operation, use, and maintenance of the Akron New Yorker Multiversal Nozzle. 1.2 Information contained
More information!! Describe different construction types of ground ladders. !! Identify the parts of a ladder including markings and labels.
1 Essentials of Fire Fighting 6 th Edition Firefighter I Chapter 12 Ground Ladders Learning Objective 1 2 Describe different construction types of ground ladders. 12 2 Learning Objective 2 3 Identify the
More information1½ Diameter Aluminum Pipe. Standard 2 1/2 shut-off with 1 1/8 MST T-handle allows members control of the nozzle.
T.B. TOOLS 7 DATA SHEET 17 1. DESCRIPTION FDNY Designation Material Weight Misc. High Rise Nozzle 1½ Diameter Aluminum Pipe Approx 10 lbs Standard 2 1/2 shut-off with 1 1/8 MST T-handle allows members
More informationThe following is a list of guidelines that apply to all evolutions.
PURPOSE: To ensure that personnel maintain a standard of performance consistent with the Memphis Fire Department s commitment to providing the community with prompt and efficient service. SCOPE: Fire Training
More informationREAR MOUNT AERIAL LADDER USED AS A WATER TOWER
EVOLUTION 21A January 1, 1997 REAR MOUNT AERIAL LADDER USED AS A WATER TOWER 1. EQUIPMENT: 2. COMMAND: 1 Rear Mount Aerial Ladder 1 Portable Ladder Pipe (Note B) 1 Halyard and Reel (Note C) 1 Siamese 3"
More informationFittings & Accessories
Fittings & Accessories 176 AKRON BRASS COMPANY PH. 800.228.1161 (330.264.5678) FAX 800.531.7335 (330.264.2944) www.akronbrass.com 630 Angle Elbow SWIVEL FEMALE x MALE 2 1 2" & 3" sizes in 30 (64 & 76 mm)
More informationEMPLOYEE ORIENTATION SKILLS
EAST LAKE TARPON SPECIAL FIRE CONTROL DISTRICT EMPLOYEE ORIENTATION SKILLS EMPLOYEE NAME: DATE: (1) EMS SKILLS 1.1 The firefighter shall demonstrate the proper technique for setting up an I.V. including
More information: 1250 gpm in the deck mode : 800 gpm while operating in the ground base - Dual Inlet : 1000 gpm while operating in the ground base - Single Inlet
APOLLO HI-RISER MONITOR STYLE 3433/3431 INSTALLATION, OPERATING, AND MAINTENANCE INSTRUCTIONS The following is intended to provide the basic instructions for installation, operation and maintenance of
More informationFIRE DEPARTMENT ACCESS Based on the 2012 edition of the International Fire Code
FIRE DEPARTMENT ACCESS Based on the 2012 edition of the International Fire Code The Fire Department is required to respond to a multitude of emergencies in various types of buildings and occupancies. These
More informationConway Fire Department
Conway Fire Department Pre-Employment Physical Agility Paperwork June 27, 2015 7:00 a.m. CFD Training Facility (1525 Sturgis Rd) YOU MUST REPORT TO THE CONWAY FIRE DEPARTMENT TRAINING SITE AT 1525 STURGIS
More informationEssentials of Fire Fighting
Essentials of Fire Fighting 6 th Edition Certified Volunteer Firefighter Chapter 16 Fire Streams Learning Objectives Explain the way vaporization and steam relate to the extinguishing properties of water.
More informationT A S K S K I L L D E S C R I P T I O N A N D D E T A I L. Revised by Engineer Jeremy Bell. January 2016 NFPA 1001 NFPA 1932
Loveland Fire Rescue Authority 410 East 5th Street Loveland, Colorado 80537 (970) 962-2471 Fax (970) 962-2922 TDD (970) 663-5144 www.cityofloveland.org G R O U N D L A D D E R O P E R A T I O N S T W O
More informationLADDER SAFETY ISSUES IN ROOFING
LADDER SAFETY ISSUES IN ROOFING Part I Ladder Selection, Setup, and Climbing This material will only cover portable extension ladders and is based on Subpart X, Title 29 Code of Federal Regulations, Part
More informationESCONDIDO FIRE DEPT TRAINING MANUAL Section Truck Module Page 1 of 6 Utilities - Controlling Revised
Truck Module Page 1 of 6 CONTROLLING UTILITIES Emergency Operations One of the initial tactical priorities for the incident commander of a structure fire is to secure the building utilities to insure the
More informationTiller Tape, Stripes, Marker Flags, and Other Clever Uses for Tape By Captain Raul A. Angulo Ladder Co. 6 Seattle Fire Department
Tiller Tape, Stripes, Marker Flags, and Other Clever Uses for Tape By Captain Raul A. Angulo Ladder Co. 6 Seattle Fire Department All photos by author except where noted Obviously for Search and Rescue
More informationMinimum required on Engine Co. Attic ladder Roof ladder with hooks Extension ladder
OBECTIVES Identify ladders required for engine companies. Demonstrate selecting ladder height. Demonstrate proper ladder placement based on task(s) to be performed and location. Demonstrate proper ladder
More informationERGONOMICS ANALYSIS Job Safety Analysis
ERGONOMICS ANALYSIS Job Safety Analysis Step 1 PROVIDE BACKGROUND Job/Task: Manual Water Supply Hose Lay Date: mm/dd/ccyy Analyzed by: Safety Consultant Location: Mosquito Heights Project Number: 01-10
More informationDriver/Operator Program Part III - Tanker
Driver/Operator Program Part III - Tanker Overview The Driver/Operator Preparation Program Part II is designed to standardize the training and release of driver/operators within the company; the intent
More informationStandardization of Fire Apparatus
HORRY COUNTY FIRE / RESCUE DEPARTMENT PROUD * PREPARED * PROFESSIONAL STANDARD OPERATING GUIDELINE APPROVED BY GARRY ALDERMAN, FIRE CHIEF: DATE: September 24, 2011 SOG 726 Standardization of Fire Apparatus
More informationMaximum Flow: 600 GPM (3800 LPM) Portable Base 1250 GPM (4800 LPM) Direct Mount. Maximum Pressure: 200 PSI (1380 Kpa, 13.8 BARS)
STYLE 3414 Apollo S.I. Monitor with FoldING Legs OPERATING & MAINTENANCE INSTRUCTIONS WITH SPECIAL L.A. COUNTY SPECIFICATIONS The Akron Style 3414 Apollo Monitor is designed to provide efficient trouble-free
More informationOPERATING & INSTRUCTION MANUAL
251 Welsh Pool Rd Exton, PA 19341 610-941- 4333 www.safetyhoistcompany.com OPERATING & INSTRUCTION MANUAL VH-300 BRIGGS & STRATTON VH-300 HONDA IMPORTANT RETAIN THIS MANUAL For instruction on assembly
More informationDay 4 March 17, Multiple Choice Identify the choice that best completes the statement or answers the question.
Day 4 March 17, 2018 Multiple Choice Identify the choice that best completes the statement or answers the question. 1. Portable fire extinguishers should be chosen based on the: A. heat of the fire. B.
More information8296 Portable Monitor Operating & Maintenance Instructions
8296 Portable Monitor Operating & Maintenance Instructions PHYSICAL: 1302 WEST BEARDSLEY AVE ELKHART, IN 46514 WWW.ELKHARTBRASS.COM MAILING: P.O. BOX 1127 ELKHART, IN 46515 1-574-295-8330 1-800-346-0250
More informationFAIRFAX COUNTY FIRE & RESCUE DEPARTMENT TRAINING BULLETIN. ISSUED BY: Captain I Daniel D. Shaw, Fire Station 409-C
FAIRFAX COUNTY FIRE & RESCUE DEPARTMENT TRAINING BULLETIN NUMBER: DATE: DISTRIBUTION: I ISSUED BY: Captain I Daniel D. Shaw, Fire Station 409-C APPROVED BY: SUBJECT: Nozzle Inspection The nozzle is a vital
More informationWelcome to the Dover Fire Department Brian F. Bashista, Fire Chief
Welcome to the Dover Fire Department Brian F. Bashista, Fire Chief How Street Width Effects EMERGENCY RESPONSE To understand why street width is so important you must first understand the mission of the
More informationBIG SPRING FIRE DEPARTMENT STANDARD OPERATING PROCEDURES SOG 417: LADDER TRUCK OPERATIONS SOP: 417. Ladder Truck Operations.
BIG SPRING FIRE DEPARTMENT STANDARD OPERATING PROCEDURES SOG 417: LADDER TRUCK OPERATIONS SOP: 417 Ladder Truck Operations Table of Contents 1. Purpose... 1 2. Safety... 1 3. Normal Operation... 2 1. Purpose
More informationCRANE OPERATION INSTRUCTION AND GUIDELINES
CRANE OPERATION INSTRUCTION AND GUIDELINES Qualifications Crane operation, to be safe and efficient, requires skill, the exercise of extreme care and good judgment, alertness and concentration, and a rigid
More informationColorado Division of Fire Prevention & Control Driver Operator Aerial JPRs (NFPA 1002, 2014 Edition)
Colorado Division of Fire Prevention & Control Driver Operator Aerial JPRs ( Edition) JPR # Task Initial Certification JPR Requirement: 14 Mandatory Renewal JPR Requirement: 100% of All JPRs (including
More informationEclipse GEN 2.0 CAFSystem, Model 150-ECL CAFS PTO Kit Installation Instructions
Eclipse GEN 2.0 CAFSystem, Model 150-ECL CAFS PTO Kit Installation Instructions Read Read through the the safety installation information instructions overhaul carefully instructions before carefully beginning
More informationRoutine Emergencies are defined as incidents that do not require the deployment of hoselines. Ex. Fire alarms, smell of smoke, etc..
15. Riding Assignments 15.1 Assignments 15.1.1 The following assignments have been developed to alleviate duplication of tasks on the fire scene. These assignments are only guides and can be changed on
More informationOther significant updates include:
THE NEW N.F.P.A. 1962 The NFPA recently revised its standard on fire hose. The newest edition requires that hose manufactured before July 1987 be removed from service. This makes sense given all the changes
More informationModel T Professional Series 1/2HP 2 YEAR WARRANTY SHALLOW WELL JET PUMP
Model T03121 SHALLOW WELL JET PUMP Professional Series 2 YEAR WARRANTY 1/2HP 916 GPH Head of 25 (7,5 m) US GPH LPH Suction: 1 1/4 NPT Discharge: 1 NPT Maximum Pressure: 65 PSI Stainless steel shaft and
More informationSLM - Sealing Liquid Monitor INSTRUCTIONS FOR USE
INSTRUCTIONS FOR USE 1/8 1 INSTALLATION SLM - Sealing Liquid Monitor INSTRUCTIONS FOR USE 1.1 Mounting The SLM has a mounting plate for simple installation. The SML can be mounted using a bolt already
More informationStar Swivel-Arm Hoist Installation and Operating Instructions
Star Swivel-Arm Hoist Installation and Operating Instructions Conveying & Hoisting Solutions P/L ABN 78 6 7. Purpose of Equipment Star Swivel-Arm Hoists are intended for the transport of materials. Star
More information( Versions Available)
STYLE 494 ELECTRIC LADDER PIPE INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS ( Versions Available) The following is intended to provide the basic instructions for installation, operating and maintenance
More informationSpacing and Pattern Effects on DU LQ of Spray Nozzles
Spacing and Pattern Effects on DU LQ of Spray Nozzles Introduction Brent Q. Mecham 1 September 11, 2006 One of the current Turf and Landscape Best Management Practices published by the Irrigation Association
More informationSTANDARD OPERATING GUIDELINES BELMONT COUNTY TANKER TASK FORCE
ACTIVATION OF TANKER TASK FORCE PROCEDURE: THROUGH PREDETERMINED AUTOMATIC AID RESPONSE OR THROUGH A REQUEST BY A HOST INCIDENT COMMANDER WHO NOTIES BELMONT COUNTY CENTRAL DISPATCH THAT THE IS REQUESTED
More informationEclipse GEN 2.0 CAFSystem, Model 150-ESECL as used with TC20 Series PTO Installation Instructions
Eclipse GEN 2.0 CAFSystem, Model 150-ESECL as used with TC20 Series PTO Installation Instructions Read Read through the the safety installation information instructions overhaul carefully instructions
More informationProfessional Series 1/2HP 2 YEAR WARRANTY CONVERTIBLE JET PUMP REPAIR PARTS
Model T033 CONVERTIBLE JET PUMP /HP 900 GPH Suction lift Head of 5 (7.5m) in shallow well mode Professional Series YEAR WARRANTY Suction: /4 Discharge: NPT Maximum pressure: 85 PSI US GPH LPH 5 900 3400
More informationMOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION
MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION Section 502 Definition 2009 International Fire Code Access Road Requirements 502.1 Fire Apparatus Access Road is a road that provides fire apparatus
More informationINSTRUCTOR GUIDE TOPIC: APPARATUS RESPONSE LEVEL OF INSTRUCTION: TIME REQUIRED: TWO HOURS MATERIALS: APPROPRIATE AUDIO-VISUAL MATERIALS
TOPIC: APPARATUS RESPONSE LEVEL OF INSTRUCTION: TIME REQUIRED: TWO HOURS INSTRUCTOR GUIDE MATERIALS: APPROPRIATE AUDIO-VISUAL MATERIALS REFERENCES: Fire Department Safety Officer, 1st ed., International
More informationHow to build a Hydraulic Ram Pump By Seth Johnson Land To House Version 1.1
Seth Johnson How to build a Hydraulic Ram Pump By Seth Johnson Land To House Version 1.1 History: A man named John Whitehurst first created the Hydraulic Ram Pump in 1772. That means that this ingenious
More informationDeveloped by Engineer Bobby Bartlett February 2012
E X T R I C A T I O N ( 1. 1 ) NFPA 1670 NFPA 1006 Developed by Engineer Bobby Bartlett February 2012 T A S K S K I L L D E S C R I P T I O N A N D D E T A I L Removal of automobile-accident victims is
More informationThe safest, lightest, most versatile initial attack monitor ever!
The safest, lightest, most versatile initial attack monitor ever! With SafeTak II Automatic Shut-Off Valve Rated Flow 500 GPM Nominal Size 2.5" Nominal Area 4.9 sq. in. Weight 22 lbs. Folded Size 25.5"
More informationFluid-O-Tech ROTOFLOW ROTARY VANE PUMP REBUILD MANUAL
Fluid-O-Tech PUMP TECHNOLOGY AT ITS BEST WWW.FLUID-O-TECH.COM Office: 161 Atwater St., Plantsville, CT 06479 Phone: (860) 276-9270 Fax: (860) 620-0193 ROTOFLOW ROTARY VANE PUMP REBUILD MANUAL 08/09 Ed.,
More informationApparatus Riding Assignments
Page: of 6 Apparatus Riding Assignments Table of Contents Page.0 Purpose.0 Responsibilities 3.0 General Rules Revisions & Effective Date Letter Description Date Prepared A New 06/0/04 TAB Prepared By:
More informationT ASK S KILL DESCRIPTION AND DETAIL
GROUND LADDER OPERATIONS T WO PERSON CARRY AND RAISE (1.2) Developed by Lt. Greg Gilbert, Engineer Shawn Williams, FF Randy Kolb, and FIT Sandra Friedrichsen March 2010 NFPA 1001 NFPA 1932 T ASK S KILL
More informationCLEARWATER FIRE & RESCUE TRAINING BUREAU
CLEARWATER FIRE & RESCUE TRAINING BUREAU TILLER OPERATOR TASK BOOK #4 Candidate Name (printed) Signature Beginning Date Candidate Station/Shift 08# Hire Date Lieutenant (print) Signature Completion date
More informationProcedure Effective date Rescinds Vehicle Placement In or Near Moving Traffic 17 November January 2005
Procedure Effective date Rescinds Vehicle Placement In or Near Moving Traffic 17 November 2008 1 January 2005 Reference Norwich Township Fire Department SOG #30 Page 1 of 6 Purpose: The purpose of this
More informationMinivator 1000 Straight Stairlift
Minivator 1000 Straight Stairlift Dolphin Stairlifts Gurlyn Farm Relubbus Penzance Cornwall TR20 9DA Phone: 01736 763580 E-mail: info@dolphinstairlifts.co.uk Web: www.dolphinstairlifts.co.uk Minivator
More informationSTANDARD OPERATING GUIDELINES
Missouri Valley Fire & Rescue Department 223 E. Erie St. Missouri Valley, IA 51555 Phone 712-642-2945 Emergency 911 STANDARD OPERATING GUIDELINES STANDARD OPERATING GUIDELINES Chronological History Effective:
More informationHead to Head Demo Comparison Sheet
Head to Head Demo Comparison Sheet Task Force Tips Handline Full Range Automatic Nozzle The purpose of this document is to encourage you to compare models head to head, apples to apples, with like models
More informationAppalachian Power Company Policy No. 15: Ladder Setup. 1) Statement of policy:
Appalachian Power Company Policy No. 15: Ladder Setup 1) Statement of policy: The use of ladders by employees is required to accomplish a variety of tasks on a routine basis. By properly carrying, setting
More informationINSTALLATION INSTRUCTIONS
2706 INSTALLATION INSTRUCTIONS -6 ! IMPORTANT PLEASE DON T HURT YOURSELF, YOUR KIT OR YOUR VEHICLE. TAKE A MINUTE TO READ THIS IMPORTANT INFORMATION. This kit is to be used on a pickup truck only, and
More informationMS Sprayers NT 1000/1250 Installation Manual MS1
MS1 MS Sprayers NT 1000/1250 Installation Manual Printed in Canada Copyright 2012 by NORAC Systems International Inc. Reorder P/N: UC4.5-BC-MS1-INST Rev B (MS Sprayer NT 1000/1250) NOTICE: NORAC Systems
More informationINSTALLATION INSTRUCTIONS
28 INSTALLATION INSTRUCTIONS SECTION - AIR SPRING SECTION 2 - AIR ACCESSORY 2-5 ! IMPORTANT PLEASE DON T HURT YOURSELF, YOUR KIT OR YOUR VEHICLE. TAKE A MINUTE TO READ THIS IMPORTANT INFORMATION. This
More informationSpray Height Controller
Spray Height Controller JD06 John Deere (4920) Installation Manual Printed in Canada Copyright 2009 by NORAC Systems International Inc. Reorder P/N: UC5-BC-JD06-INST Rev F (John Deere 4920) NOTICE: NORAC
More informationElectrical Safety. Electricity. Safety. Division of Workers Compensation HS01-013B(02-14)
Electrical Safety Electricity Safety Division of Workers Compensation HS01-013B(02-14) Table of Content Respect The Power Of Electricity 3 Inform Your Supervisor Of Faulty Equipment 3 Wear Protective Clothing
More informationThank you for purchasing a Nelson RainTrain2.
Thank you for purchasing a Nelson RainTrain2. Read this manual carefully to learn how to operate and service your machine properly. Failure to do so can result in personal injury and/or property damage.
More informationIntroduction. Module 7 (Training & Equipment Manual 304)
Introduction Module 7 (Training & Equipment Manual 304) Critical fireground operations rely on proper placement of ladders Photos courtesy of Anthony Delucia, Thomas Lenart,Chris Saracenco and Robert Yates
More informationCity State Zip Code City State Zip Code
Town of Brighton Office of the Fire Marshal Fire Apparatus Access and Fire Hydrant Worksheet The information contained in this worksheet is provided solely for the convenience of determining compliance
More informationINSTALLATION INSTRUCTIONS
2807 INSTALLATION INSTRUCTIONS SECTION - AIR SPRING SECTION 2 - AIR ACCESSORY -6 ! IMPORTANT PLEASE DON T HURT YOURSELF, YOUR KIT OR YOUR VEHICLE. TAKE A MINUTE TO READ THIS IMPORTANT INFORMATION. This
More informationFire Engine Information
Fire Engine Information City of Thornton Fire Engine 71 2001 American La France This engine was built entirely by Freightliner/American La France. The National Fire Protection Association (NFPA) and Insurance
More informationESCONDIDO FIRE DEPT TRAINING MANUAL Section DRIVER OPERATOR Page 1 of 10 Apparatus Service Tests Revised
DRIVER OPERATOR Page 1 of 10 APPARATUS SERVICE TESTING Pump Testing Pumps test are generally classified into two types based on when they are performed. The first is the Acceptance Test. The Acceptance
More informationSpray Height Controller
Spray Height Controller JD10 John Deere (4930) with Proportional Main Lift Installation Manual Printed in Canada Copyright 2009 by NORAC Systems International Inc. Reorder P/N: UC5-BC-JD10-INST Rev G (John
More informationNMSU FIRE DEPARTMENT FIRE PUMP ACCEPTANCE TEST
Date Documents Submitted: Log No.: File No.: Plan Examiner: Permit No.: Property Information Building Name: Building Address: Building Manager's Name: Building Manager's Phone: Fax: System Designer/Contractor
More informationInstallation Instructions Table of Contents
Installation Instructions Table of Contents Pre- Installation of Garage Storage Lift 2 Layout the Garage Storage Lift 3 Installing the strut Channels 3 Install the Drive Assembly 5 Install the Drive Shaft
More informationPosition Number Community Division/Region Yellowknife North Slave
IDENTIFICATION Department Position Title Infrastructure Firefighter Position Number Community Division/Region 33-7791 Yellowknife North Slave PURPOSE OF THE POSITION The Firefighter is responsible for
More informationEL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD
EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD STANDARD #B-004 EFFECTIVE 06-30-2009 REVISED 7-20-2017 1. PURPOSE 1.1. During an emergency event, it is essential that emergency vehicles are provided
More informationGEORGIA DEPARTMENT OF CORRECTIONS Standard Operating Procedures IVN Authority: Effective Date: Page 1 of WETHERINGTON/HODGE 4/01/02 5
GEORGIA DEPARTMENT OF CORRECTIONS Standard Operating Procedures Functional Area: SUPPORT SERVICES/FIRE SERVICES Subject: EMERGENCY OPERATIONS/MOTOR VEHICLE FIRES Revises Previous Authority: Page 1 of WETHERINGTON/HODGE
More informationNSGV EVE-ER I, O, & M MANUAL
TABLE OF CONTENTS Rail Layout.. Page 1 Support Placement...Page 1 Rail Assembly.Page 1 Rail Duct Connections.. Page 2 Rubber Lip Installation.. Page 3 Pneumatic End Stop. Page 4 End Stop. Page 4 End Cap..
More informationNORTH COUNTY FIRE AUTHORITY POLICY & PROCEDURE MANUAL OPERATIONS
PURPOSE: This policy and procedure describes the actions to be taken in the event of an emergency resulting from a fire, explosion, spill, or any unplanned sudden or non sudden release of hazardous waste
More informationADO-Pumping Apparatus Manipulative Skill Objectives PREVENTIVE MAINTENANCE
ADO-Pumping Apparatus Manipulative Skill Objectives PREVENTIVE MAINTENANCE 1. Perform and document routine tests, inspections, and servicing functions on specified systems and components. A. For a fire
More informationLSU University Safety Manual Section IV, Part C Stairs and Ladders. C. Stairs & Ladders
C. Stairs & Ladders 1. General Requirements a. A stairway or ladder must be provided at all worker points of access where there is a break in elevation of 19 inches (48 cm) or more and no ramp, runway,
More informationEnsure staff are trained in use of equipment
Work at height Can you avoid working at height in the first place? No Yes Plan the task required Risk assess the task required Ensure staff are trained in use of equipment Ensure equipment has been correctly
More informationRelay Pumping Operations
Relay Pumping Operations OBJECTIVES Identify potential water sources Demonstrate acquiring water from various water sources Demonstrate proper relay pumping hydraulic calculations Demonstrate proper relay
More information21 Keep Residential Stairwells & Hallways Lit During Blackouts
NEW CODE FURTHER ACTION 21 Keep Residential Stairwells & Hallways Lit During Blackouts I. Summary Issue: All buildings are required to have 90 minutes of emergency lighting so they can be safely evacuated.
More informationLightweight Aluminum Alloy Adapters
Lightweight Aluminum Alloy Adapters Double Swivel Female......for adapting from male to female. Made from extruded lightweight aluminum alloy, then hardcoated to resist corrosion and abrasion. Ship. wt.
More informationBusiness Plan We will reflect the National Treasure in which we live
Business Plan 2017 We will reflect the National Treasure in which we live Fire Departments depend on equipment and personnel to accomplish their tasks. Those tasks vary from each agency but the City of
More informationFire Department Access & Water Supply
ROSEBURG FIRE DEPARTMENT FIRE PREVENTION DIVISION fireprevention@cityofroseburg.org 700 SE Douglas Avenue Roseburg, OR 97470 Phone (541) 492-6770 Fire Department Access & Water Supply This brochure is
More informationHome Elevator. Planning Guide
Home Elevator Planning Guide Please note: Dimensions provided in this Guide are for REFERENCE ONLY and should not be used for site preparation or construction. 2 Table of Contents Elvoron Home Elevator...4
More informationHD 7700 Setup & Operator Manual
HD 7700 Setup & Operator Manual Issue 1 December, 01 Performance Design Inc. The Heavy Duty Ultima (HD 7700) electric punch has been designed to punch most any job that may pass through your bindery or
More informationJEEVES. JEEVES Installation Manual. Installation Manual The Easiest Do-It-Yourself Dumbwaiter on the Market
1 888-323-8755 www.nwlifts.com JEEVES Installation Manual The Easiest Do-It-Yourself Dumbwaiter on the Market This manual will cover the installation procedure step-by-step. The installation of this dumbwaiter
More informationADAPTERS & VALVES CAPS GASKETS STORZ ADAPTERS THREADED ADAPTERS. /adapters 2 1 /2" 3" 4" 4 1 /2" 5" 6" AC728: Male
ADAPTERS & VALVES CAPS GASKETS STORZ ADAPTERS THREADED ADAPTERS VALVES DOUBLE SWIVEL FEMALE......for adapting from male to female. Made from extruded lightweight aluminum alloy, then hardcoated to resist
More informationOperator s Manual. CH-200 Platform Material Hoist. (610)
CH-200 Platform Material Hoist info@safetyhoistcompany.com (610) 941-4333 www.safetyhoistcompany.com TABLE OF CONTENTS GENERAL RECOMMENDATIONS & ADVICE...1 GENERAL SAFETY INSTRUCTIONS...2-3 SAFE OPERATION...4
More informationINSTALLATION INSTRUCTIONS
www.burcam.com 2190 Dagenais Blvd.West TEL: 514.337.4415 LAVAL (QUEBEC) FAX: 514.337.4029 CANADA H7L 5X9 info@burcam.com INSTALLATION INSTRUCTIONS MODEL 506518SS AND BY-PRODUCTS LIKE Your pump has been
More informationPlacement on the fireground simply refers to how and where an apparatus is placed at the scene.
Placement on the fireground simply refers to how and where an apparatus is placed at the scene. The success of fireground operations can directly or indirectly depend on the effective placement of fire
More informationSTYLE 3463 FireFox. With Position Feedback Potentiometer
STYLE 3463 FireFox INSTALLATION, OPERATING and MAINTENANCE INSTRUCTIONS With Position Feedback Potentiometer The following is intended to provide the basic instructions for installation, operating and
More information