ESCONDIDO FIRE DEPARTMENT TRAINING MANUAL DRIVER OPERATOR PUMPING PAGE 1 OF 6 Nozzles & Hose Revised
|
|
- Bertha Sutton
- 5 years ago
- Views:
Transcription
1 PUMPING PAGE 1 OF 6 TFT Task Force Tip Combination Nozzles There are two sizes of hand line nozzles, 1 ½ and 2 ½. Our 1 ½ nozzles are Task Force Tip (TFT) combination nozzles. They are primarily designed for structure fire attack and are carried on t he 1 ¾ transverse pre-connects and 1 ¾ bundles. The GPM selections available are OFF, 30, 60, 95,125,150, 175 (KK Only), 200, and FLUSH at 100 PSI nozzle pressure. The default GPM in Escondido is 95 GPM. Any change to the GPM must be communicated with the Engineer. Other departments in the zone use 150 as the default GPM. The storage settings are 30- degree fog, 95 GPM with the bail off. The 2 ½ combination nozzles are Akron nozzles. They are primarily designed for structure fire attack. They are located in a compartment and must be retrieved for use. The GPM selections are 125, 150, and 200, 250 and FLUSH at 100 PSI nozzle pressure. The default GPM setting in the zone is 250 GPM. Any change to the GPM must be communicated with the Engineer. The storage settings are 30-degree fog and 250 GPM. Break Away Feature Both the 1 ½ and 2 ½ combination nozzles have the ability to separate the nozzle tip from the shut off while the line is charged. This feature can be used to extend with another section of hose. When extending a line the nozzle tip has an OFF position and may be used independently from the shut off butt. The other purpose of the breakaway feature is only used when flushing doesn t remove an obstruction and immediate water application is needed for firefighter safety. The Captain should immediately call for a second line and move to a position of safety until the obstruction can be cleared. Smooth Bore Nozzles Escondido currently does not carry 1 ½ smooth bore nozzles for structure fire attack. When used as structure nozzles, the 1 ½ smooth bore tip sizes are either 7/8 or 15/16 and flow 150 GPM and 180 GPM respectively.
2 PUMPING PAGE 2 OF 6 Break Away The 2 ½ smooth bore nozzles are carried in a compartment next to the 2 ½ Combination nozzle. The tip sizes are 1, 1 1/8 and 1 ¼ flowing 210, 270, and 330 GPM respectively at 50 PSI nozzle pressure. Note: the ¾ tip on the Stang/Monitor is for wild land only and should be removed for structure attack. When removed it leaves the 1 ½ tip which will flow 600 GPM at 80 PSI. When used for wild land it is pumped at 50 PSI flowing 119 GPM. This allows for approximately 2 1/2 minutes of tank water. The Captain may order a higher nozzle pressure for larger GPM flows but must be aware this will lessen the time it can be used. Pattern Combination nozzles are capable of a straight stream of 10 degrees to a full fog of 90 degrees and all the degrees in between. All the way to the left is full fog and all the way to the right is straight stream. They are stored in a 30-degree fog. This allows for easier pattern adjustments to either straight stream or fog before initiating fire attack. When operating in the offensive strategy, the straight stream is the pattern of choice. In this pattern more of the water reaches supercharged pre or post-flashover environments and provides lifesaving cooling. Another aspect is it lessens the steam production in the working area and helps maintain thermal balance. Straight stream settings and smooth bore nozzles can have unwanted effects such as causing heated windows to break changing the air flow and punching through dry wall allowing fire access to the attic or other spaces. Wider fog application inside involved structures that are thought to be occupied is strongly discouraged. Water converts to steam at an 1800:1 ratio. Since moisture
3 PUMPING PAGE 3 OF 6 transfers heat at a much higher rate than dry air, occupants in the vicinity can be adversely effected. Additionally, the amount of air that a combination nozzle operating at >30-degrees entrains is enough air to intensify fire behavior and change air flow Smooth bore nozzles are less prone to the effects of wind when operated outside and generally deliver a tighter cone of water at a greater distance. F-60 & FS-95: (1-1/2") These nozzles are multiple GPM hand spray pattern nozzles (commonly referred to as forestry nozzles). Beginning with the tip turned all the way clockwise, the flow is shut off. Rotating the tip counter clockwise, the first setting is an impinging straight stream of 20 GPM. Continuing counter clockwise, the next setting is a 30 fog pattern at 20 GPM. After the 30 pattern is another impinging straight stream which will increase in GPM as the tip continues counter clockwise, until you reach either 60 or 95 GPM. Continuing to turn the tip will give you a fog pattern, at 60 or 95 GPM, which will widen out to virtually 180. The 60 and 95 GPM settings are designed to deliver adequate amounts of water for firefighting purposes. The 20 GPM settings are designed for mop-up and overhaul operations or when conservation of water is a primary concern. F GPM (most common on E.F.D.) FS GPM
4 PUMPING PAGE 4 OF 6 Note: On progressive hose evolutions, the starting engine pressure is 100 psi plus friction loss -- adjustments to pressure called for by nozzle firefighter. The F-60 nozzle is the combination nozzle of choice for wildland. TFT Bubble Cup Nozzle: (1 & 1 ½ ) The Task Force Tips Bubble Cup nozzles are hand-held nozzles with clean far reaching straight stream. They are adjustable from straight stream to a wide fog pattern. Their construction is compatible with the use of fresh water as well as firefighting foam solutions. The nozzles are rated at 100 PSI. The 1 nozzle will deliver either 10 GPM or 40 GPM. The 1 ½ nozzle is rated at 20 GPM and 95 GPM. The Bubble Cup nozzle is capable of producing aspirated foam as well as a conventional straight stream and wide protective fog pattern. The Bubble Cup functions just like a dual flow nozzle (a nozzle where the flow setting is changed by rotating the shaper, which also controls the spray pattern) when the gray sleeve is in the retracted position. To use the aspirating feature of the Bubble Cup, the nozzle operator need only slide the gray sleeve portion of the nozzle forward. When the sleeve is in the fully extended position, a white line on the shaper will be visible at the base of the gray sleeve. Rotation of the shaper when the sleeve is extended will provide the nozzle operator control of reach and aspiration. If an immediate wide protective fog pattern is needed, the sleeve can be retracted instantly to its regular position. Master TFT-R (MTFT-R): The MTFT is a single deluge nozzle for all flows from GPM, all patterns, and for all master stream applications. This nozzle is on our truck companies mounted as part of the basket yoke system. As an "automatic" nozzle, the MTFT pressure control nozzle mechanism within the nozzle senses the pressure at the base of the nozzle. Slight adjustments in the discharge opening are automatically made to maintain the correct 100 psi nozzle pressure for the flow that is being delivered.
5 PUMPING PAGE 5 OF 6 Cellar Nozzles: (2-1/2 inch) 9 Hole GPM at 100 psi The nine outlet Cellar nozzle has three 9/16", three 5/8" and three 1/2" outlets. For quick mental calculations, figure the nine outlet as equal to a 1-1/4" tip. AKRON APOLLO PORTABLE MONITOR The Akron Apollo Portable Monitor is equipped with a single 4" intake with a female swivel connector. The monitor comes equipped with a multi-gallon-selection combination fog and straight stream nozzle. The four constant gallon-selection settings are 500, 750, 1000, and 1250 GPM at 100 psi. The 1-3/8, 1-1/2", 1-3/4", and 2" straight bore tips can also be used on the portable monitor. Do not exceed 1000 GPM when operating with the portable base. The base is equipped with spikes, a six-foot adjustable safety chain, and two tie-down straps to keep the unit from sliding when in operation. Attach the safety chain when possible. Elevation is by worm gear and locks in any position 90` above horizontal to 15` below horizontal with an elevation stop at 35`. Do not release the 35' elevation stop and operate below that point in the portable base. The 1 3/8 tip is kept off of the stacked tips. In its place is a ¾ wild land tip. The wild land tip should be removed for structure applications. This leaves the 1 ½ tip which flows 600 GPM at 80 PSI. The ¾ tip is only for wild land applications and should be pumped at 50 PSI which will flow 119 GPM for approximately 2 1/2 minutes on flat ground with tank water. The Captain may order a higher nozzle pressure for larger GPM flows but must be aware this will lessen the time it can be used. The intent of the ¾ wild land tip is for quick knockdown of the forward rate of spread of a wild fire and should be followed by hand lines as soon as possible.
6 PUMPING PAGE 6 OF 6 Safety Precautions The two connecting pins must be fully engaged at all times. Secure safety chain when operating. Do not lower past safety stop when on the ground. Each spike must be in uniform contact with the ground surface and all spikes must be driven into the surface at least 1/8". When used in a portable base, the unit should not be operated at more than 1000 GPM. Tip Size Nozzle Pressure GPM FL/100-4" Hose 1-3/8" /2" / Fog Platform Nozzles Both trucks have one automatic combination nozzle and one smooth bore nozzle. While the individual flows of each nozzle added together equal much more, the combined or individual GPM capacity of is closer to the capacity of the yoke and water way. This flow shouldn t be exceeded. The combination nozzle is rated at 250 to PSI. The smoothbore is a 1 3/8 tip to a 2 tip. A stream shaper is attached to the nozzle and the tips to reduce turbulence.
ESCONDIDO FIRE DEPT TRAINING MANUAL Section DRIVER OPERATOR Page 1 of Sutphen Elevating Platform Revised
DRIVER OPERATOR Page 1 of 5 ELEVATING PLATFORM The platform is suspended in the yoke, anchored on each side with special self- aligning bearings and special high-tensile steel bolts. The SPH 100 has a
More informationAKRON BRASS COMPANY PH ( ) FAX ( )
Mercury Monitors The Mercury Monitors are the newest innovation in firefighting equipment. These monitors are smaller than any other portable ground monitor so it can be quickly set up and left unmanned
More informationESCONDIDO FIRE DEPARTMENT TRAINING MANUAL ENGINE MODULE HOSE PAGE 1 OF 20 Supply Hose Lays Revised
HOSE 12-01-16 PAGE 1 OF 20 There are five base North Zone supply hose lays: Forward Lay Spotting a Hydrant Stationary Lay Reverse Lay Split Lay Escondido Fire Department Core Hose Lays The Escondido Fire
More informationESCONDIDO FIRE DEPT TRAINING MANUAL Section DRIVER OPERATOR Page 1 of Sutphen Aerial Operations Revised
DRIVER OPERATOR Page 1 of 10 1997 Sutphen Aerial Operations Revised 12-11-17 PROCEDURES FOR ELEVATING THE PLATFORM Placing the aerial platform into service requires qualified personnel trained in the proper
More informationUltraJet Nozzle. AKRON BRASS COMPANY PH ( ) akronbrass.com
UltraJet Nozzle 4 AKRON BRASS COMPANY PH. 800.228.1161 (330.264.5678) akronbrass.com The UltraJet combines the powerful punch of a true smooth bore and the widespread protection of a full fog. This nozzle
More informationThe safest, lightest, most versatile initial attack monitor ever!
The safest, lightest, most versatile initial attack monitor ever! With SafeTak II Automatic Shut-Off Valve Rated Flow 500 GPM Nominal Size 2.5" Nominal Area 4.9 sq. in. Weight 22 lbs. Folded Size 25.5"
More informationEssentials of Fire Fighting
Essentials of Fire Fighting 6 th Edition Certified Volunteer Firefighter Chapter 16 Fire Streams Learning Objectives Explain the way vaporization and steam relate to the extinguishing properties of water.
More informationESCONDIDO FIRE DEPT TRAINING MANUAL Section DRIVER OPERATOR Page 1 of Sutphen Aerial Operations Revised
DRIVER OPERATOR Page 1 of 12 2014 Sutphen Aerial Operations Revised 12-11-17 PROCEDURES FOR ELEVATING THE PLATFORM Placing the aerial platform into service requires qualified personnel trained in the proper
More informationESCONDIDO FIRE DEPT TRAINING MANUAL Section ENGINE MODULE Page 1 of 12 Special Operations Revised
ENGINE MODULE Page 1 of 12 SPECIAL HOSE OPERATIONS The information presented in this section covers a variety of hose-handling methods. These special operations include: Connecting hoses to fire department
More informationAKRON NEW YORKER MULTIVERSAL NOZZLE
TRAINING BULLETIN TOOLS 17 June, 1983 1. INTRODUCTION 1.1 This training bulletin is issued to govern the operation, use, and maintenance of the Akron New Yorker Multiversal Nozzle. 1.2 Information contained
More informationNOZZLES NOZZLES SPECIALTY SABERJET NOZZLES THE FIRST TRULY MULTI-PURPOSE NOZZLE
NOZZLES COMBINATION CONSTANT GAL. PIERCING NOZZLES PLAYPIPES SELECTABLE GAL. SHUTOFFS SMOOTH BORE SPECIALTY /nozzles 1.800.323.0244 EDARLEY.COM/NOZZLES Shop NOZZLES AUTOMATIC SABERJET NOZZLES THE FIRST
More informationNOZZLES HANDLINE NOZZLES MASTER STREAM PIERCING NOZZLES PLAYPIPES
NOZZLES HANDLINE NOZZLES MASTER STREAM PIERCING NOZZLES PLAYPIPES Shop DARLEY FIRE STORM NOZZLE DELIVERS QUALITY AND PERFORMANCE The new Fire Storm nozzle delivers the quality and performance you are looking
More informationNOZZLES NOZZLES DARLEY FIRE STORM NOZZLE DELIVERS QUALITY AND PERFORMANCE TURBOJET NOZZLES NEW LOW PRICE
NOZZLES HANDLINE NOZZLES MASTER STREAM PIERCING NOZZLES /nozzles NOZZLES Shop PLAYPIPES DARLEY FIRE STORM NOZZLE DELIVERS QUALITY AND PERFORMANCE 1.800.323.0244 EDARLEY.COM/NOZZLES The new Fire Storm nozzle
More informationColor-Coded Polymer Pistol Grip, Valve Handle Covers offer rugged durability in harsh fi refi ghting conditions
Domestic Catalog G-Force Nozzles: The Inside Story Based on a highly customizable global nozzle platform design, the unique G-Force series of fi xed, selectable, and automatic nozzles combine over 40 years
More informationDarley Fire Storm Nozzle
Darley Fire Storm Nozzle Quality and Performance The new Fire Storm nozzle delivers the quality and performance you are looking for in a selectable nozzle with the value you expect from Darley. Choose
More informationSCAN IT, WATCH IT! Smartphone video link. Multiple Flow Settings. High Visibility Reflective Operating Labels. With or Without Pistol Grip
Turbojet Nozzles The Akron adjustable gallonage Turbojet nozzle is unmatched in today s fire service for its' flexibility and flow control. The Turbojet is a constant gallonage nozzle (flow remains the
More informationMANUAL: Twister and BubbleCup Nozzles
MANUAL: Twister and BubbleCup Nozzles INSTRUCTIONS FOR SAFE OPERATION AND MAINTENANCE Read instruction manual before use. Operation of this device without understanding the manual and receiving proper
More information8296 Portable Monitor Operating & Maintenance Instructions
8296 Portable Monitor Operating & Maintenance Instructions PHYSICAL: 1302 WEST BEARDSLEY AVE ELKHART, IN 46514 WWW.ELKHARTBRASS.COM MAILING: P.O. BOX 1127 ELKHART, IN 46515 1-574-295-8330 1-800-346-0250
More informationHead to Head Demo Comparison Sheet
Head to Head Demo Comparison Sheet Task Force Tips Quadrafog and Thunderfog Selectable Gallonage Nozzle The purpose of this document is to encourage you to compare TFT products head to head, apples to
More informationSTYLE 624, 638 QUICK-ATTACK FOAM TUBE INSTALLATION, OPERATING, AND MAINTENANCE INSTRUCTIONS
STYLE 624, 638 QUICK-ATTACK FOAM TUBE INSTALLATION, OPERATING, AND MAINTENANCE INSTRUCTIONS The following is intended to provide the basic instructions for installation, operation, and maintenance. Read
More informationTRAINING BULLETIN APPARATUS P-2 January 22, 1998 FLOWMETERS
TRAINING BULLETIN APPARATUS P-2 January 22, 1998 FLOWMETERS 1. INTRODUCTION 1.1 The intention of this bulletin is to describe the operation and calibration of the SPAN FLOWMINDER, the flowmeter presently
More informationTurboJet Nozzles. SaberJet Nozzles NOZZLES. The First Truly Multi-Purpose Nozzle. SaberJet Single Shutoff Nozzle. SaberJet Dual Shutoff Nozzle
TurboJet Nozzles The Akron adjustable gallonage TurboJet nozzle is unmatched in today s fire service for its flexibility and flow control. The TurboJet is an adjustable gallonage nozzle, where flow remains
More informationIntegrated Stream Shaper Reflective band. Safety strap and hook. Compact folding legs
MONITORS MercuryMaster1000 Monitor The MercuryMaster1000 is the newest innovation to the portable monitor line. This monitor is the smallest and lightest of all 1000 gpm monitors in the firefighting industry.
More informationIn U.S./International Akron Brass Company P.O. Box 86 Wooster, OH PH: Fax:
In U.S./International Akron Brass Company P.O. Box 86 Wooster, OH 44691 PH: 330.264.5678 Fax: 330.264.2944 Toll Free: 800.228.1161 Toll Free Fax: 800.531.7335 E-Mail: akroncare@idexcorp.com www.akronbrass.com
More informationNOZZLES HANDLINE NOZZLES MASTER STREAM PIERCING NOZZLES PLAYPIPES
NOZZLES HANDLINE NOZZLES MASTER STREAM PIERCING NOZZLES PLAYPIPES Shop DARLEY FIRE STORM NOZZLE DELIVERS QUALITY AND PERFORMANCE The new Fire Storm nozzle delivers the quality and performance you are looking
More informationCompact Wildland Attack
2017 8000 gpm Industrial Monitor Compact Wildland Attack TFT's Storm Monitor envisioned on this brush truck using virtual reality Storm RC is less than 13 " tall (without nozzle) 1 Our Most Compact RC
More information: 1250 gpm in the deck mode : 800 gpm while operating in the ground base - Dual Inlet : 1000 gpm while operating in the ground base - Single Inlet
APOLLO HI-RISER MONITOR STYLE 3433/3431 INSTALLATION, OPERATING, AND MAINTENANCE INSTRUCTIONS The following is intended to provide the basic instructions for installation, operation and maintenance of
More informationPage 6-6. Page 6-3. Page 6-3. Page 6-5. Self- Educting Foam. Foam Compatible. Location
SELECTOR GUIDE 6-1 AUTOMATIC AUTOMATIC X-STREAM SM-10FE AVAILABLE BASE 1.5 2.5 3.5 1.5 2.5 3.5 300-2000 (1136-7571) 20-120 (76-454) PRODUCT DESCRIPTION MATERIAL Page 6-6 Page 6-3 Simplifies fireground
More informationSTYLE 5148 MERCURYMASTER OSCILLATING NOZZLE INSTALLATION, OPERATING, AND MAINTENANCE INSTRUCTIONS
STYLE 5148 MERCURYMASTER OSCILLATING NOZZLE INSTALLATION, OPERATING, AND MAINTENANCE INSTRUCTIONS The following is intended to provide the basic instructions for installation, operation, and maintenance.
More informationIndustrial Electric Monitors. Industrial
Industrial Electric Monitors Corrosion resistant monitors with maximum travel for optimal coverage in industrial, mining and marine environments. Severe-Duty Monitor 750 GPM (2900 LPM) The Severe-Duty,
More informationTRAINING BULLETIN TOOLS 7 December, 1978 HOSE NOZZLES (HAND HELD) 1. NOZZLE NOMENCLATURE AND IDENTIFICATION
TRAINING BULLETIN TOOLS 7 December, 1978 1. NOZZLE NOMENCLATURE AND IDENTIFICATION 1.1 A nozzle identification and nomenclature system is established to insure that issuance and recall of equipment as
More informationInnovative Firefighting Products
Innovative Firefighting Products TFT Offers Flow Efficient Water Supply and Innovative Appliance Solutions to Responders Worldwide Flow efficiency, a lightweight compact design, and long-term corrosion
More informationColorado Division of Fire Prevention & Control Driver Operator Aerial JPRs (NFPA 1002, 2014 Edition)
Colorado Division of Fire Prevention & Control Driver Operator Aerial JPRs ( Edition) JPR # Task Initial Certification JPR Requirement: 14 Mandatory Renewal JPR Requirement: 100% of All JPRs (including
More informationMaximum Flow: 600 GPM (3800 LPM) Portable Base 1250 GPM (4800 LPM) Direct Mount. Maximum Pressure: 200 PSI (1380 Kpa, 13.8 BARS)
STYLE 3414 Apollo S.I. Monitor with FoldING Legs OPERATING & MAINTENANCE INSTRUCTIONS WITH SPECIAL L.A. COUNTY SPECIFICATIONS The Akron Style 3414 Apollo Monitor is designed to provide efficient trouble-free
More informationHead to Head Demo Comparison Sheet
Head to Head Demo Comparison Sheet Task Force Tips Handline Full Range Automatic Nozzle The purpose of this document is to encourage you to compare models head to head, apples to apples, with like models
More informationFAIRFAX COUNTY FIRE & RESCUE DEPARTMENT TRAINING BULLETIN. ISSUED BY: Captain I Daniel D. Shaw, Fire Station 409-C
FAIRFAX COUNTY FIRE & RESCUE DEPARTMENT TRAINING BULLETIN NUMBER: DATE: DISTRIBUTION: I ISSUED BY: Captain I Daniel D. Shaw, Fire Station 409-C APPROVED BY: SUBJECT: Nozzle Inspection The nozzle is a vital
More informationSPECIFICATIONS FOR PTO DRIVEN ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B 2000 M-P SPECIFICATIONS FOR FIRE FIGHTING SYSTEM
SPECIFICATIONS FOR PTO DRIVEN ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B 2000 M-P SPECIFICATIONS FOR FIRE FIGHTING SYSTEM HIGH PRESSURE FIRE FIGHTING SPECIFICATIONS Scope and General Design Requirements
More informationPyrolance, LLC PTO-HYDRAULIC DRIVEN ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B 2000 M-P
== B-2000 M-P, PTO, Manual - 2013.002 11/26/13 == SPECIFICATIONS FOR PTO-HYDRAULIC DRIVEN ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B 2000 M-P 1 SPECIFICATIONS FOR FIRE FIGHTING SYSTEM HIGH PRESSURE FIRE
More informationSTYLE 5148 MERCURYMASTER OSCILLATING NOZZLE INSTALLATION, OPERATING, AND MAINTENANCE INSTRUCTIONS
STYLE 5148 MERCURYMASTER OSCILLATING NOZZLE INSTALLATION, OPERATING, AND MAINTENANCE INSTRUCTIONS The following is intended to provide the basic instructions for installation, operation, and maintenance.
More informationFOAM AQUEOUS FILM FORMING FOAM (AFFF) ALCOHOL RESISTANT AQUEOUS FILM FORMING FOAM (AR-AFFF) NEW FOAM CONCENTRATE FOAM NOZZLES FOAM SYSTEMS EDUCTORS
FOAM FOAM CONCENTRATE FOAM NOZZLES FOAM SYSTEMS EDUCTORS TESTING KITS 1.800.323.0244 EDARLEY.COM/FOAM FOAM Shop AQUEOUS FILM FORMING FOAM (AFFF) Aqueous Film Forming Foam (AFFF) - is a specially formulated
More informationWILLIAMS FIRE & HAZARD CONTROL, INC. MAURICEVILLE, TEXAS WILLIAMS BTM MONITOR NOZZLE
WILLIAMS FIRE & HAZARD CONTROL, INC. MAURICEVILLE, TEXAS 77662 1-800-231-4613 WILLIAMS BTM MONITOR NOZZLE INSTALLATION, OPERATION & MAINTENANCE MANUAL TABLE OF CONTENTS 1. Warning & Safety Information
More informationAlpha Tech Pet, Inc. HydroMAID - "Mobile Automated Integrated Diluter" Rechargeable Battery
Alpha Tech Pet, Inc. HydroMAID - "Mobile Automated Integrated Diluter" Rechargeable Battery WEAR ALWAYS THANK YOU FOR CHOOSING OUR PRODUCTS Please use this equipment carefully and observe all warnings
More information590G Series Golf Spray Head. 590G Series Golf Spray Head. Variable Arc 4, 6, 12 Pop-up X-Flow and Check-O-Matic Standard.
590G Series Golf Spray Head 590G Series Golf Spray Head Variable Arc 4, 6, 12 Pop-up X-Flow and Check-O-Matic Standard Specifications Radius: 2' 18' (,6 5,5m) Maximum operating pressure: 75 psi (5,2 Bar)
More informationBasalt Fire-Rescue Engine 43 Inspection
Updated 8/9/17 Date of inspection OIC Truck Cab Map book/reference book/sop book HazMat pocket guide (glovebox) CO Monitor Motorola portable radio (1 with headset for driver/operator) (3) Traffic vests
More informationPyrolance, LLC SPECIFICATIONS FOR DIESEL ENGINE DRIVEN ULTRA HIGH PRESSURE PIERCING AND FIRE FIGHTING SYSTEM L 1000 W-D
SPECIFICATIONS FOR DIESEL ENGINE DRIVEN ULTRA HIGH PRESSURE PIERCING AND FIRE FIGHTING SYSTEM L 1000 W-D 1 SPECIFICATIONS FOR FIRE FIGHTING SYSTEM FIRE FIGHTING AND PIERCING SPECIFICATIONS Scope and General
More informationPyrolance, LLC SPECIFICATIONS FOR DIESEL ENGINE DRIVEN ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B2000 M-D
SPECIFICATIONS FOR DIESEL ENGINE DRIVEN ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B2000 M-D 1 HIGH PRESSURE FIRE FIGHTING SPECIFICATIONS Scope and General Design Requirements A fire fighting system shall
More informationDIKE AND SPILL PROTECTION
1 DIKED AREA Dikes are typically constructed around above ground storage tanks. They are contours of land or physical barriers that will retain fuel to a depth greater than 1". At many manufacturing or
More informationREAR MOUNT AERIAL LADDER USED AS A WATER TOWER
EVOLUTION 21A January 1, 1997 REAR MOUNT AERIAL LADDER USED AS A WATER TOWER 1. EQUIPMENT: 2. COMMAND: 1 Rear Mount Aerial Ladder 1 Portable Ladder Pipe (Note B) 1 Halyard and Reel (Note C) 1 Siamese 3"
More informationTHE REVOLUTIONARY STINGER
THE REVOLUTIONARY STINGER 2.0 There is no product like the revolutionary Stinger 2.0 from Elkhart Brass! This firefighter-friendly monitor is super lightweight for easy carrying and handling. It combines
More informationFOR INSTALLATION, SAFE OPERATION AND MAINTENANCE
MANUAL: Twister and BubbleCup Nozzles INSTRUCTIONS FOR INSTALLATION, SAFE OPERATION AND MAINTENANCE Read instruction manual before use. Operation of this nozzle without understanding the manual and receiving
More informationB Pump Mounting. Page 1 of 7
www.wildlandwarehouse.com P.O. Box 425 Blairstown, NJ 07825 Ph 1.866.WILDLAND Fx 908.362.6236 October 18, 2012 Specifications for our Standard 50, 75 or 100 gallon UTV Fire Suppression Skid Unit L Shaped
More information24-Hour Turnaround Factory Service 24-Hour Technical Hot-line: ORDERING INFORMATION THREAD ORDERING INFORMATION
Customer Technical Service: Customer Sales: International Sales: sts@tft.com sales@tft.com intsales@tft.com www.tft.com 24-Hour Turnaround Factory Service 24-Hour Technical Hot-line: 800-348-2686 ORDERING
More information5000 Series Rotors 5000, Plus, PRS, SAM
Tech Spec 5000 Series Rotors 5000, Plus, PRS, SAM Built from top to bottom with the contractor in mind, the Rain Bird 5000 Series product line is the durable, reliable rotor for residential and commercial
More informationSTYLE 3462 FORESTRY BUMPER MONITOR INSTALLATION, OPERATING and MAINTENANCE INSTRUCTIONS
STYLE 3462 FORESTRY BUMPER MONITOR INSTALLATION, OPERATING and MAINTENANCE INSTRUCTIONS The following is intended to provide the basic instructions for installation, operating and maintenance of the 3462
More informationCONTENTS 10 COMMON QUESTIONS ABOUT AUTOMATIC NOZZLES
10 COMMON QUESTIONS ABOUT AUTOMATIC NOZZLES 1) How is an automatic nozzle different from a regular (conventional) nozzle? 2) How does an automatic nozzle work? 3) What pressure do we pump to automatic
More informationSTYLE 3491 Severe Duty Electric Mining Water Cannon INSTALLATION, AND OPERATING INSTRUCTIONS
STYLE 349 Severe Duty Electric Mining Water Cannon INSTALLATION, AND OPERATING INSTRUCTIONS Australian Only The following is intended to provide the basic instructions for installation, operating and maintenance
More informationBackpack Sprayer. Use and Care Manual
Backpack Sprayer Use and Care Manual BACKPACK SPRAYER CAUTION: Read and follow all instructions Do Not Return This Backpack To The Store For Help, Information or Parts, Call : 1-800-311-9903 The Fountainhead
More information32 quarts Transmission Allison HT 740 Automatic Fluid
BOOK: Blue Book I SECTION: E-One Engine (SGT) Page 1 of 6 E-ONE CYCLONE TABLE OF CONTENTS SPECIFICATIONS... 2 DAILY CHECKS... 2 SAFETY CHECKS... 3 START ENGINE... 3 STOP ENGINE... 3 EMERGENCY SHUTDOWN
More informationTo establish a standardized procedure for Class B foam application by engine companies.
PURPOSE: DATE Reviewed June 27, 2013 SARASOTA COUNTY GOVERNMENT EMERGENCY SERVICES DIRECTIVE VOLUME #2 FIRE OPERATIONS NUMBER #223 CATEGORY RECOMMENDED OPERATING GUIDELINE SUBJECT Class B FOAM EQUIPMENT
More information570Z Series. Reliability is simply stated in. 570Z Series 20 years of solid. performance. Add to that its. extensive product line offering and
570Z Series S P R I N K L E R S RESIDENTIAL COMMERCIAL Reliability is simply stated in 570Z Series 20 years of solid performance. Add to that its extensive product line offering and you have a successful
More informationFOAM AQUEOUS FILM FORMING FOAM (AFFF) ALCOHOL RESISTANT AQUEOUS FILM FORMING FOAM (AR-AFFF) NEW FOAM CONCENTRATE FOAM NOZZLES FOAM SYSTEMS EDUCTORS
FOAM FOAM CONCENTRATE FOAM NOZZLES FOAM SYSTEMS EDUCTORS TESTING KITS 1.800.323.0244 EDARLEY.COM/FOAM FOAM Shop AQUEOUS FILM FORMING FOAM (AFFF) Aqueous Film Forming Foam (AFFF) - is a specially formulated
More informationSuperior Performance
QMAX MIDSHIP PUMP Superior Performance QMAX Superior Performance The Qmax single stage mid-ship pump generates NFPA 1901 rated flows up to 2,250 GPM (8,515 LPM) from draft True 2,000 GPM rated pump body
More informationSTYLE 3463 FireFox. With Position Feedback Potentiometer
STYLE 3463 FireFox INSTALLATION, OPERATING and MAINTENANCE INSTRUCTIONS With Position Feedback Potentiometer The following is intended to provide the basic instructions for installation, operating and
More informationTECHNICAL DATA 1-1/2 (dn40)
July 1, 2011 Deluge Valves 209a DESCRIPTION The Viking Model E-3 1-1/2 Deluge Valve is a quick-opening, differential type flood valve with a rolling diaphragm clapper. The deluge valve is used to control
More informationTECHNICAL DATA. Q= C v P S
1 of 9 1. DESCRIPTION The Viking Model E-1 Deluge Valve is a quick-opening, differential diaphragm, flood valve with one moving part. The deluge valve is used to control water flow in deluge and preaction
More informationTECHNICAL DATA. Q= C v P Cv = Flow Factor (GPM/1 PSI P)
1 of 9 1. DESCRIPTION The Viking 2 (DN50) is a quick-opening, differential diaphragm, flood valve with one moving part. The deluge valve is used to control water flow in deluge and preaction sprinkler
More informationCompact Cleaning System
Series 9900 Compact Cleaning System THANK YOU FOR CHOOSING OUR PRODUCTS Please use this equipment carefully and observe all warnings and cautions. WEAR ALWAYS protective clothing and eyewear when working
More information1½ Diameter Aluminum Pipe. Standard 2 1/2 shut-off with 1 1/8 MST T-handle allows members control of the nozzle.
T.B. TOOLS 7 DATA SHEET 17 1. DESCRIPTION FDNY Designation Material Weight Misc. High Rise Nozzle 1½ Diameter Aluminum Pipe Approx 10 lbs Standard 2 1/2 shut-off with 1 1/8 MST T-handle allows members
More informationICS Integrated Cleaning System. Rechargeable Battery
ICS 8900 Integrated Cleaning System Rechargeable Battery THANK YOU FOR CHOOSING OUR PRODUCTS Hydro Systems manufactures quality chemical proportioners. Please use this equipment carefully and observe all
More information( Versions Available)
STYLE 494 ELECTRIC LADDER PIPE INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS ( Versions Available) The following is intended to provide the basic instructions for installation, operating and maintenance
More informationJune Drill of the Month Instructor Guide. Topic: Review of Hydraulics and Pump Components
Course: Pumps Refresher Course Session Reference: 1 June Drill of the Month Instructor Guide Topic: Review of Hydraulics and Pump Components Level of Instruction: Time Required: 3 hours Materials: Chalkboard
More informationFoam Supply Kits FOAM EDUCTORS FOAM EDUCTORS FOAM EDUCTORS FOAM SUPPLY KITS
FOAM SUPPLY KITS Foam Supply Kits Elkhart offers two supply kits. Both kits include: One.75 quarter-turn, inlet valve assembly with elbow Quick-connect female coupling Quick-connect plug with chain Brushed
More informationFoam Supply Kits FOAM EDUCTORS FOAM EDUCTORS FOAM EDUCTORS FOAM SUPPLY KITS
FOAM SUPPLY KITS Foam Supply Kits Elkhart offers two supply kits. Both kits include: One.75" quarter-turn, inlet valve assembly with elbow Quick-connect female coupling Quick-connect plug with chain Brushed
More informationHandline Nozzles. Foam Tubes In Line eductors & Piercing Nozzle. Forestry Products. Firehouse cleaning Products
Fourth Edition Table of Contents Handline Nozzles Foam Tubes In Line eductors & Piercing Nozzle Playpipes & Shutoffs Smooth Bore Tips & Repair kits Forestry Products Monitors DELUGE Tips Master Stream
More informationBASIC FOAM FIREFIGHTING OPERATIONS Red and Green Systems
BASIC FOAM FIREFIGHTING OPERATIONS Red and Green Systems Page 730.60 Each of the Red and Green Foam Systems consists of one 3000 gallon foam concentrate storage tank, two foam concentrate pumps, a balanced
More informationTWO FULLY EQUIPPED PUMPERS STATIC AND PRESSURIZED WATER SOURCES REFERENCES: ESSENTIALS OF FIRE FIGHTING, FOURTH EDITION, IFSTA, CHAPTERS 11 AND 12
INSTRUCTOR GUIDE TOPIC: BACK TO BASICS: ESTABLISHING SUPPLY LINES TIME REQUIRED: THREE HOURS MATERIALS: TWO FULLY EQUIPPED PUMPERS STATIC AND PRESSURIZED WATER SOURCES REFERENCES: ESSENTIALS OF FIRE FIGHTING,
More informationMANUAL: ThunderFog, QuadraFog and QuadraCup
MANUAL: ThunderFog, QuadraFog and QuadraCup INSTRUCTIONS FOR INSTALLATION, SAFE OPERATION AND MAINTENANCE Read instruction manual before use. Operation of this nozzle without understanding the manual and
More informationPumping Apparatus Driver/Operator Types of Apparatus Equipped with a Pump. Chapter Test
Chapter 1 Test Name: Date: Directions: Write the correct letter on the blank before each question. Objective 1: Describe fire department pumpers. 1. The main purpose of fire department pumpers is to: (13)
More informationNORTH COUNTY FIRE AUTHORITY POLICY & PROCEDURE MANUAL OPERATIONS
PURPOSE: This policy and procedure describes the actions to be taken in the event of an emergency resulting from a fire, explosion, spill, or any unplanned sudden or non sudden release of hazardous waste
More information05 Water Pressure Systems INTRODUCTION
52 05 Water Pressure Systems INTRODUCTION Pressure Controlled Diaphragm Pumps Pressure controlled diaphragm pumps provide boat owners with a fresh water system that is as easy to use as their domestic
More informationSystem Background and Operation
Pty Limited 1/48 Racecourse Road RUTHERFORD NSW 2320 Telephone: (02) 4932 0111 Facsimile: (02) 4932 0222 E-mail:hyden@hydeneng.com.au ABN: 17 129 010 902 ENVIROSPRAY Manual Manual Number: 06500976A Manual
More informationTrailer Sprayer Owner s Manual
Trailer Sprayer Owner s Manual Models: T4052B, T40D53B, T40D52BL 1910 Lookout Drive North Mankato, MN 56003 2011 Model Year 40 GALLON 12-VOLT TRAILER SPRAYER OWNER S MANUAL OPERATION: 1. Partially fill
More informationLIST PRICE GUIDE. ALL PRICES IN U.S. DOLLARS Effective: August 1, 2011 AKRON BRASS COMPANY TERMS AND CONDITIONS
LIST PRICE GUIDE ALL PRICES IN U.S. DOLLARS Effective: August 1, 2011 AKRON BRASS COMPANY TERMS AND CONDITIONS TERMS: All U.S. sales are Net 30 days. All International sales are ex-factory or D.D.U. (Delivered
More information2017 FULL LINE PRODUCT CATALOG
2017 FULL LINE PRODUCT CATALO A Brand You Can Trust hat makes Akron Brass the world s most trusted brand of firefighting and emergency response equipment? Focused customer insight, advanced manufacturing,
More informationTHD-SERIES S11DA280 THRU S27DA1020 & S11SR280 THRU S27SR1020 DOUBLE ACTING & SPRING RETURN SCOTCH YOKE ACTUATORS
THD-SERIES S11DA280 THRU S27DA1020 & S11SR280 THRU S27SR1020 DOUBLE ACTING & SPRING RETURN SCOTCH YOKE ACTUATORS INTRODUCTION A-T Controls THD scotch yoke actuators have been designed and engineered to
More informationOPTIONS SLIP-ON FIREFIGHTING UNITS
OPTIONS SLIP-ON FIREFIGHTING UNITS 2.0 CF-126 Diesel Pump & Engine The pump shall be a CFE #24193 high pressure centrifugal pump powered by a Briggs & Stratton Vanguard in-line 3 cylinder, water-cooled,
More informationESCONDIDO FIRE DEPT TRAINING MANUAL Section Engine Module Page 1 of 12 Wildland Back Fire Burn Out Revised
Engine Module Page 1 of 12 BACKFIRE/BURNOUT OPERATIONS During wildland firefighting operations firefighters occasionally fight the fire with fire. In situations where the flame length exceeds 15 or the
More informationDeicer Operating Instructions Table of Contents
Deicer Operating Instructions Table of Contents FMC FMC FMC/Trump FMC Global Premier Trump Model: LA1000 Model: LMD-2000 Model: T2000 Model: TM1800 Model: 2100TE Model: HC29050 Model: D240 Contents FMC
More informationInnovative Firefighting Products
Innovative Firefighting Products Water Supply Equipment: Intake and Hydrant Valves, Manifolds and Appliances Pages 6-7 From a simple sketch on a napkin by founder Clyde McMillan that started the company
More informationSPECIFICATIONS FOR GASOLINE DRIVEN ENGINE ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B1000 M-G
SPECIFICATIONS FOR GASOLINE DRIVEN ENGINE ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B1000 M-G Scope and General Design Requirements A firefighting system shall be provided for offensively attacking a fire.
More informationESCONDIDO FIRE DEPT TRAINING MANUAL Section DRIVER OPERATOR Page 1 of 10 Apparatus Service Tests Revised
DRIVER OPERATOR Page 1 of 10 APPARATUS SERVICE TESTING Pump Testing Pumps test are generally classified into two types based on when they are performed. The first is the Acceptance Test. The Acceptance
More informationGTX. 1 of 9. The GTX scrubber s 2 recover drain and hose are larger than those on many other machines, making the GTX scrubber less likely to clog.
The GTX scrubber uses larger (8 stainless) hinges and bolt directly into the heavy gage steel frame. This provides better durability than other machines that use smaller tank hinges bolted to plastic tanks.
More informationGT-200 GATE VALVES PN16, Screwed end
Document No. : MD-QO-04-281 Date : 2009/07 /17 Version : 1.0 GT-200 GATE VALVES PN16, Screwed end USER MANUAL Modentic Industrial Corporation 14F-1,No.57Taya Rd.,Taichung,Taiwan,R.O.C. Email:modentic@ms9.hinet.net
More informationMANUAL: Foam Nozzles and Foam Attachments for TFT Nozzles
MANUAL: Foam Nozzles and Foam Attachments for TFT Nozzles INSTRUCTIONS FOR SAFE OPERATION AND MAINTENANCE WARNING Understand manual before use. Operation of this device without understanding the manual
More informationSalt Brine De-Icing & Dust Control Systems
Salt Brine De-Icing & Dust Control Systems BARR Plastics Inc www. 2016 Table of Contents Brine Makers 3 4 Contractor Brine Maker SBS300 Municipal Brine Maker SBS750 Brine Maker Applicator Combo Units 5-6
More informationCOVER FEATURE FIRECHIEF.COM
COVER FEATURE While many believe that smooth-bore nozzles offer better penetration and knockdown ability than combination nozzles, scientific analysis suggests otherwise. 58 August 2011 FIRECHIEF.COM Unconventional
More informationDarley UHP-HV Diesel Specification 1
Darley UHP-HV Diesel Specification 1 This dual pump is designed for either a powerhead type unit or a full module. The module provides a self-contained diesel powered slide-in type ultra high pressure
More informationWest Metro Fire Protection District
West Metro Fire Protection District Developing Firefighter Instructions The following is an outline of what you are to achieve in relation to a Brush Truck (Type 6). You may or may not be assigned to a
More informationPROMAG SR SERIES SEAL-LESS CENTRIFUGAL PUMPS
PROMAG SR SERIES SEAL-LESS CENTRIFUGAL PUMPS INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS TO OBTAIN THE BEST PERFORMANCE FROM YOUR PROMAG SR PUMP, PLEASE READ THE MANUAL CAREFULLY. Failure to
More informationTECHNICAL DATA. Viking Technical Data may be found on Style: 90 Degree Pattern (inlet to outlet)
Flow Control 500a DESCRIPTION The Viking 1-1/2 is a quick opening, differential type flood valve with a spring loaded rolling diaphragm clapper. The can be used to facilitate manual or automatic on/off
More information