TRAINING BULLETIN TOOLS 7 December, 1978 HOSE NOZZLES (HAND HELD) 1. NOZZLE NOMENCLATURE AND IDENTIFICATION

Size: px
Start display at page:

Download "TRAINING BULLETIN TOOLS 7 December, 1978 HOSE NOZZLES (HAND HELD) 1. NOZZLE NOMENCLATURE AND IDENTIFICATION"

Transcription

1 TRAINING BULLETIN TOOLS 7 December, NOZZLE NOMENCLATURE AND IDENTIFICATION 1.1 A nozzle identification and nomenclature system is established to insure that issuance and recall of equipment as well as adaptation or utilization instructions for nozzles will be facilitated and/or understood. 1.2 One-piece nozzles, or the components of multi-piece nozzles, will be designated and marked by a letter or letters identifying the nozzle or part, followed by a number which will identify the specific F.D.N.Y. model; in some cases a size designation will be included. 1.3 Data Sheets, describing the specific item will be issued when new appliances are introduced into the department, or to describe existing equipment. Such Data Sheets will make up the Appendix to this bulletin. 2. DEFINITIONS* AND DESIGNATIONS 2.1 A nozzle is a hose line appliance that is either single unit or multi-unit, in that it is composed of one or more sub-assemblies. It is used to direct the flow of water increase the velocity or flow, or disperse the water in small droplets or fog** in various patterns. 2.2 The basic parts of any nozzle are described in this section. In addition, the appropriate Data Sheet will list pertinent technical data, including: Manufacturer Waterway size, Inlet and Outlet threads, Hydraulic characteristics, Overall dimensions, Weight, Operating instructions, etc. * Illustrations will supplement these definitions; specific minor terms are only defined on the illustrations. ** There is a technical difference between the term "fog" and "spray". For our purposes, all devices that produce dispersed streams will be termed "fog" unless specifically designated "spray". 1

2 2.2.1 SHUT-OFF (SO) Figure 1- That section of the nozzle that contains the water control valve. It is identified by the letters "SO" TIP - in attachment usually connected to a SO, or a hose butt; it performs the basic function of the nozzle and is designed in various forms. The characteristics of Solid Stream tips and nozzles are determined by tip design. The patterns and flows of fog stream tips and nozzles are determined by special designs. A. SOLID STREAM TIPS are generally Stacked. 1. Stacked Tips for hand lines are limited to two individual tips. a- MAIN SOLID STREAM TIP (MST) [Figure 2] - is fitted with threads at its outlet orifice, is the first tip of the stack, and is attached directly to a SO. b- OUTER SOLID STREAM TIP (OST) [Figure 3] - does not have outlet orifice threads, and is threaded at its inlet for attachment to a MST to further reduce bore diameter. The 1/2" tip is a OST. B. FOG TIPS are fog producing devices. 1. FOG TIP (FT), Figure 4- the most common types have an outer rotating barrel which is used for stream adjustments and, in some models, as a shut-off. 2. Most FT's are classified as Combination Straight stream/ Fog devices. The straight stream is hollow and the fog patterns depend on adjustments permitted by the Outer Rotating Barrel. C. Other tips are designed for various specific functions and are generally named according to their purpose; i.e., foam pick-up, extension, low velocity fog, etc. Data Sheets will be issued detailing their nomenclature and identification, etc FOG NOZZLE (FN), Figure 5- is defined as a fog producing device that contains, addition to the Outer Rotating Barrel, a ball-type shut-off as an integral part of its assembly DUAL NOZZLE (DN), Figure 6- contains separate discharge orifices and permits selective discharge, usually by means of a shut-off with more than two positions. 2

3 2.2.5 Some other definitions are: A. OPEN NOZZLE, Figure 7- is basically a solid stream tip designed to be attached directly to the hose butt. It differs from MST in that no threads are provided at its outlet orifice. B. CONTROLLING NOZZLE- any nozzle which contains a mechanism for controlling the flow of water at the nozzle. C. WORKING NOZZLE- any nozzle carried attached to hose in the hose bed of the apparatus. 2.3 FTs AND FNs MAY BE OF VARYING DESIGN: CONSTANT FLOW OR VARIABLE FLOW - These terms define what occurs to the amount of water being discharged when the pattern selection is changed. A. CONSTANT FLOW - Once a given flow had been established, a flow will remain constant and will not vary if the discharge pattern is changed. Because of this feature, member must be aware that the volume discharged may be less than required. B. VARIABLE FLOW - Once a given flow has been established, flow will vary if the discharge pattern is changed. For example, more water is generally delivered in the fog position than in the straight stream position CONSTANT PRESSURE OR VARIABLE PRESSURE - These terms define what occurs to the nozzle pressure when the amount of water being supplied to the tip/nozzle is increased or decreased. A. CONSTANT PRESSURE (Automatic)- Should be understood to mean, that the nozzle pressure remains practically constant within the operational limits of the automatic feature of the tip (for the FT-2, 65 to 105 PSI), as the water being supplied is increased or decreased. Changes in pattern selection will not affect nozzle pressure This type of tip automatically adjusts the orifice size, thus keeping the nozzle pressure practically constant. Consequently, the reach will also remain practically constant. Because of this feature members must be aware that the volume discharged may be less than required. A sure sign of this condition would be reduced nozzle reaction (easier handling), while the stream appears to remain unchanged. B. VARIABLE PRESSURE (Non Automatic) - Nozzle pressure will vary directly as the water being supplied is increased or decreased. Depending on nozzle 3

4 design, nozzle pressure may or may not be affected by chances in pattern selection. 2.4 Tips or nozzles that produce fog depend on two basic actions described as PERIPHERAL or IMPINGING Fog is developed in the Peripheral type (Figures 4 & 5) by directing a stream of water against a baffle which deflects the water through serrated teeth at the periphery, which action separates disperses water into fine droplets THE IMPINGING NOZZLE (Figure 6) includes a series of small orifices which cause multiple streams to impinge on each other. The impingement breaks the water into fixed, non adjustable fog pattern. 3. NOZZLE MAINTENANCE 3.1 All hose fittings equipment should be regularly examined and cleaned to insure that they are always in good condition and ready for immediate operational use. 3.2 A systematic program for this maintenance not only insures that equipment is maintained in firstclass condition at all times but also that personnel become thoroughly familiar with it and get to know exactly where each item is kept on the apparatus. This knowledge is essential if members are to operate quickly and efficiently at fire operations. 3.3 When cleaning nozzles, particular attention should be given to insuring that all moving parts operate freely; that any rough edges or projections which might damage the hose are smoothed or removed, and that residue from paint or polish is removed from places where it may tend to block holes, threads or passages, and thus reduce operating efficiency. 3.4 Nozzles should be washed out and thoroughly checked for any defects before being placed back in service following use. Nozzles should be washed in solution of soap and hot water. Submerge the nozzle and work the mechanism until free movement is obtained, then rinse in water. Nozzles should be examined after use and any obstructions removed. A. Special care must be taken to insure that there is no obstruction in the orifice between the baffle and the rim of fog tips, otherwise poor streams of fog will result. Also, combination SS/Fog devices shall be placed in straight stream position (turned to the right) at all times when stored on apparatus or in hose bed. This will avoid possible damage to the baffle. 4

5 December, 1978 B Tips depend for their efficiency upon the true circular opening of the outlet orifice and upon an undamaged lip, and care should be taken when cleaning them. C Particular attention must be given to the inlet orifice diameter of any of the solid stream tips to make certain it equals the outlet orifice diameter of the SO to which it is attached. If it is smaller and the lip of the inlet orifice projects as a sharp edge into the bore, the stream will be severely limited (coefficients of discharge may vary from normal.998 to.80 or worse). Units when discovering this condition, shall promptly forward the tip to Division of Repairs & Transportation to have the inlet orifice adjusted. Adjustment usually consists of chamfering (beveling) the lip to avoid a sharp projection into the waterway. 3.5 Nozzle/Tip couplings which, due to damage, cannot be connected without difficulty should be taken out of service until such time as they can be repaired or replaced. A faulty coupling left in service may well be the cause of delay in getting a vitally important line of hose to work on a fire. 3.6 Excessive force should not be used to tighten nozzle components or couplings as this may damage the washer and cause leakage. 3.7 A light coating of oil should be put on all couplings and moving parts after cleaning. 3.8 Officers supervising the operation of hose streams shall keep OST in their possession when they are removed from nozzles. Similarly, FT shall be in the officer's possession when not attached to a SO or hose butt. 3.9 Identifying letters and numbers placed on nozzles and components shall be stamped on the coupling along the hub, adjacent to the coupling lug Until conditions require removal, the OST (½" tip) shall always be attached to the nozzle Nozzles shall be carried in an accessible position on the apparatus, protected from damage. Neither the control handles of SOs and FNs, nor the shut-off valve itself shall be used for the purposes of holding or clamping nozzles to holders To prevent mechanical damage, nozzles should be handled with care. They should not be dropped or thrown aside When using a nozzle, care should be taken not to twist or bend control handles. Either of these conditions may prevent the control valve from opening fully or may permit the valve to go past the full opening. In both cases the bore would not be fully opened and the result would be a broken stream and/or reduced flow to the fire Nozzle mechanisms should work freely. If for any reason a control sticks, the nozzle should immediately be taken out of service and sent for repairs. It should never be necessary to 5

6 December, 1978 hammer a control handle or apply excessive torque, by hand or mechanically, to a rotating type control to make it operate. 6

7 3.15 Controlling nozzles will be tested annually in August and whenever deemed necessary in accordance with schedules established by Division Commanders as follows: A. Two lengths of hose (100') shall be stretched from the pumper, nozzle attached, water started and sufficient pressure developed to attain an effective stream. B. Shut offs shall be opened and closed several times as in normal operating procedures, and nozzles operated (MST, OST, FT) throughout their various positions and pressures. C. Nozzles found defective shall be removed from service and forwarded to the Repairs and Transportation Unit for necessary repairs New issue or repaired nozzles shall be tested in accordance with Section 3.15 before being placed in service. FIGURE 1 Typical Shut-Off (SO) 7

8 FIGURE 2 Typical Main Solid Stream Tip (MST) Hub Converging Cylindrical section section of bore of bore Washer space Inlet Orifice Diameter Outlet Orifice Diameter Coupling Female (generally 1 1/2 FDNY Thread) FIGURE 3 Typical Outer Solid Stream Tip (OST) Male threads are compatible with discharge outlet threads of 3/4, 15/16, 1 1/8, 1 1/4, MST Inlet Leather Washer Hub 1/2 Outlet Cylindrical section of bore 8

9 Rim FIGURE 4 Typical Comb. SS/FOG* Tip (FT) Baffle Serrated Teeth Tip may have raised (braille-like) Pattern indicators and/or click stops Outer Rotating Barrel Sleeve Coupling Lug (pin type) *Straight Stream/Fog Coupling - Swivel or non-swivel female base 1 1/2 or 2 1/2 thread Rim Baffle Nozzle may have raised (braille-like) pattern indicators and/or click stops FIGURE 5 Typical Comb. SS/FOG* Nozzle (FN) Serrated Teeth In some models rubber /plastic guard Outer rotating barrel Sleeve Integral shut-off Shut-off handle Coupling lug (pin type) *Straight Stream/Fog 9 Coupling swivel or non-swivel female base 1 1/2 or 2 1/2 thread

10 FIGURE 6 Typical Dual Nozzle (DN) TRIPLE ACTION HANDLE OFF Forward position FOG Middle position SOLID STREAM Back position Shut-off handle Swivel or non-swivel base 1 1/2 or 2 1/2 thread Solid stream orifice Impinging jet for high velocity fog Shut-off Tip removable if extension applicator (low velocity fog) is desired 10

8296 Portable Monitor Operating & Maintenance Instructions

8296 Portable Monitor Operating & Maintenance Instructions 8296 Portable Monitor Operating & Maintenance Instructions PHYSICAL: 1302 WEST BEARDSLEY AVE ELKHART, IN 46514 WWW.ELKHARTBRASS.COM MAILING: P.O. BOX 1127 ELKHART, IN 46515 1-574-295-8330 1-800-346-0250

More information

FAIRFAX COUNTY FIRE & RESCUE DEPARTMENT TRAINING BULLETIN. ISSUED BY: Captain I Daniel D. Shaw, Fire Station 409-C

FAIRFAX COUNTY FIRE & RESCUE DEPARTMENT TRAINING BULLETIN. ISSUED BY: Captain I Daniel D. Shaw, Fire Station 409-C FAIRFAX COUNTY FIRE & RESCUE DEPARTMENT TRAINING BULLETIN NUMBER: DATE: DISTRIBUTION: I ISSUED BY: Captain I Daniel D. Shaw, Fire Station 409-C APPROVED BY: SUBJECT: Nozzle Inspection The nozzle is a vital

More information

UltraJet Nozzle. AKRON BRASS COMPANY PH ( ) akronbrass.com

UltraJet Nozzle. AKRON BRASS COMPANY PH ( ) akronbrass.com UltraJet Nozzle 4 AKRON BRASS COMPANY PH. 800.228.1161 (330.264.5678) akronbrass.com The UltraJet combines the powerful punch of a true smooth bore and the widespread protection of a full fog. This nozzle

More information

Essentials of Fire Fighting

Essentials of Fire Fighting Essentials of Fire Fighting 6 th Edition Certified Volunteer Firefighter Chapter 16 Fire Streams Learning Objectives Explain the way vaporization and steam relate to the extinguishing properties of water.

More information

AKRON NEW YORKER MULTIVERSAL NOZZLE

AKRON NEW YORKER MULTIVERSAL NOZZLE TRAINING BULLETIN TOOLS 17 June, 1983 1. INTRODUCTION 1.1 This training bulletin is issued to govern the operation, use, and maintenance of the Akron New Yorker Multiversal Nozzle. 1.2 Information contained

More information

SCAN IT, WATCH IT! Smartphone video link. Multiple Flow Settings. High Visibility Reflective Operating Labels. With or Without Pistol Grip

SCAN IT, WATCH IT! Smartphone video link. Multiple Flow Settings. High Visibility Reflective Operating Labels. With or Without Pistol Grip Turbojet Nozzles The Akron adjustable gallonage Turbojet nozzle is unmatched in today s fire service for its' flexibility and flow control. The Turbojet is a constant gallonage nozzle (flow remains the

More information

PENTECH, INC. BD Spray Gun. Operating Manual Parts Manual May, 2008 Issue 1. Plural Component, Impingement Mixing, Mechanical Purge Spray Gun

PENTECH, INC. BD Spray Gun. Operating Manual Parts Manual May, 2008 Issue 1. Plural Component, Impingement Mixing, Mechanical Purge Spray Gun PENTECH, INC. Operating Manual Parts Manual May, 2008 Issue 1 Plural Component, Impingement Mixing, Mechanical Purge Spray Gun BD Spray Gun PENTECH, INC. 7256 21 st Street East Sarasota, FL 34243 Phone:

More information

ESCONDIDO FIRE DEPARTMENT TRAINING MANUAL DRIVER OPERATOR PUMPING PAGE 1 OF 6 Nozzles & Hose Revised

ESCONDIDO FIRE DEPARTMENT TRAINING MANUAL DRIVER OPERATOR PUMPING PAGE 1 OF 6 Nozzles & Hose Revised PUMPING 06-30-17 PAGE 1 OF 6 TFT Task Force Tip Combination Nozzles There are two sizes of hand line nozzles, 1 ½ and 2 ½. Our 1 ½ nozzles are Task Force Tip (TFT) combination nozzles. They are primarily

More information

Type D3S PROTECTOSPRAY Directional Spray Nozzles, Open, Medium Velocity General Description. Technical Data. Page 1 of 6 AUGUST 2018 TFP804

Type D3S PROTECTOSPRAY Directional Spray Nozzles, Open, Medium Velocity General Description. Technical Data. Page 1 of 6 AUGUST 2018 TFP804 Worldwide Contacts www.tyco-fire.com Type D3S PROTECTOSPRAY Directional Spray Nozzles, Open, Medium Velocity General Description The Type D3S Protectospray Nozzles are open (non-automatic) directional

More information

Table of Contents Visual Inspection and Neutralizing... 3 Disassembly

Table of Contents Visual Inspection and Neutralizing... 3 Disassembly 1 Table of Contents Visual Inspection and Neutralizing... 3 Disassembly... 3... 4... 4 Cleaning... 4 Inspection... 4 Reconditioning of Valve Seats... 5 Lapping Procedures... 5 Lapping Blocks... 5 Lapping

More information

SPRAYTECS Series UP High Velocity Directional Spray Nozzles, Open, Non-Automatic. Suitable for Water Spray fixed systems.

SPRAYTECS Series UP High Velocity Directional Spray Nozzles, Open, Non-Automatic. Suitable for Water Spray fixed systems. Spraytecs technologies ltd SPRAYTECS Series UP High Velocity Directional Spray Nozzles, Open, Non-Automatic. Suitable for Water Spray fixed systems. Technical Data General Description The SPRAYTECS Series

More information

Head to Head Demo Comparison Sheet

Head to Head Demo Comparison Sheet Head to Head Demo Comparison Sheet Task Force Tips Handline Full Range Automatic Nozzle The purpose of this document is to encourage you to compare models head to head, apples to apples, with like models

More information

TRAINING BULLETIN APPARATUS P-2 January 22, 1998 FLOWMETERS

TRAINING BULLETIN APPARATUS P-2 January 22, 1998 FLOWMETERS TRAINING BULLETIN APPARATUS P-2 January 22, 1998 FLOWMETERS 1. INTRODUCTION 1.1 The intention of this bulletin is to describe the operation and calibration of the SPAN FLOWMINDER, the flowmeter presently

More information

TECHNICAL SERVICE MANUAL

TECHNICAL SERVICE MANUAL TECHNICAL SERVICE MANUAL HEAVY-DUTY bracket mounted PUMPS SERIES 4193 AND 493 SIZES GG - AL SECTION TSM 154 PAGE 1 of 10 ISSUE C CONTENTS Introduction....................... 1 Special Information...................

More information

LESSON 2 BASIC CONSTRUCTION AND OPERATION OF HYDRAULIC ACTUATING DEVICES, FLOW CONTROL, AND DIRECTIONAL DEVICES. STP Tasks:

LESSON 2 BASIC CONSTRUCTION AND OPERATION OF HYDRAULIC ACTUATING DEVICES, FLOW CONTROL, AND DIRECTIONAL DEVICES. STP Tasks: LESSON 2 BASIC CONSTRUCTION AND OPERATION OF HYDRAULIC ACTUATING DEVICES, FLOW CONTROL, AND DIRECTIONAL DEVICES STP Tasks: 552-758-1003 552-758-1071 OVERVIEW LESSON DESCRIPTION: In this lesson you will

More information

WILLIAMS FIRE & HAZARD CONTROL, INC. MAURICEVILLE, TEXAS WILLIAMS BTM MONITOR NOZZLE

WILLIAMS FIRE & HAZARD CONTROL, INC. MAURICEVILLE, TEXAS WILLIAMS BTM MONITOR NOZZLE WILLIAMS FIRE & HAZARD CONTROL, INC. MAURICEVILLE, TEXAS 77662 1-800-231-4613 WILLIAMS BTM MONITOR NOZZLE INSTALLATION, OPERATION & MAINTENANCE MANUAL TABLE OF CONTENTS 1. Warning & Safety Information

More information

SERIES G3DB/AG3DB ELEVATOR

SERIES G3DB/AG3DB ELEVATOR TM INSTRUCTIONS AND PARTS LIST SERIES G3DB/AG3DB ELEVATOR WARNING This manual, and GENERAL INSTRUCTIONS MANUAL, CA-1, should be read thoroughly prior to pump installation, operation or maintenance. SRM00059

More information

AN EXPLANATION OF CIRCUITS CARTER YH HORIZONTAL CLIMATIC CONTROL CARBURETER

AN EXPLANATION OF CIRCUITS CARTER YH HORIZONTAL CLIMATIC CONTROL CARBURETER AN EXPLANATION OF CIRCUITS CARTER YH HORIZONTAL CLIMATIC CONTROL CARBURETER The Carter Model YH carbureter may be compared with a Carter YF downdraft carbureter with the circuits rearranged to operate

More information

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description Technical Services: Tel: () 31-931 / Fax: () 791-55 Model F thru F3 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description The Mulsifyre Nozzles are open (nonautomatic) nozzles and

More information

ATTENTION! READ BEFORE ATTACHING THE AIR HOSE

ATTENTION! READ BEFORE ATTACHING THE AIR HOSE Binks SV50 HVLP GRAVITY FEED SPRAY GUN & TOUCHUP GUN ATTENTION READ BEFORE ATTACHING THE AIR HOSE HVLP AIR SUPPLY REQUIREMENTS FULL SIZE GUN: 30 PSI inlet pressure provides 10 PSI at the air cap. Consumes

More information

Maintenance Information

Maintenance Information 16573370 Edition 2 February 2014 Air Grinder 99V Series Maintenance Information Save These Instructions Product Safety Information WARNING Failure to observe the following warnings, and to avoid these

More information

Handline Nozzles. Foam Tubes In Line eductors & Piercing Nozzle. Forestry Products. Firehouse cleaning Products

Handline Nozzles. Foam Tubes In Line eductors & Piercing Nozzle. Forestry Products. Firehouse cleaning Products Fourth Edition Table of Contents Handline Nozzles Foam Tubes In Line eductors & Piercing Nozzle Playpipes & Shutoffs Smooth Bore Tips & Repair kits Forestry Products Monitors DELUGE Tips Master Stream

More information

FLANGE. Flanges used for

FLANGE. Flanges used for FLANGE FLANGE Flanges with rating class designations 150, 300, 400, 600, 900, 1500, and 2500 in sizes NPS 1 2 through NPS 24 ASME B16.5: Pipe Flanges and Flanged Fittings (NPS 24 ) ASME B16.47: NPS 26

More information

SM64052 Maintenance & Repair Manual Commercial 2" Unisex Coupling - Valved Model 64052

SM64052 Maintenance & Repair Manual Commercial 2 Unisex Coupling - Valved Model 64052 Aerospace Group Conveyance Systems Division Carter Brand Ground Fueling Equipment SM64052 July 2004 Applicable additional manuals: SM64051 Commercial 2" Unisex Coupling, Non-Valved Maintenance & Repair

More information

Page 6-6. Page 6-3. Page 6-3. Page 6-5. Self- Educting Foam. Foam Compatible. Location

Page 6-6. Page 6-3. Page 6-3. Page 6-5. Self- Educting Foam. Foam Compatible. Location SELECTOR GUIDE 6-1 AUTOMATIC AUTOMATIC X-STREAM SM-10FE AVAILABLE BASE 1.5 2.5 3.5 1.5 2.5 3.5 300-2000 (1136-7571) 20-120 (76-454) PRODUCT DESCRIPTION MATERIAL Page 6-6 Page 6-3 Simplifies fireground

More information

Directional Spray Nozzles, Open, with Strainers High Velocity General Description

Directional Spray Nozzles, Open, with Strainers High Velocity General Description Worldwide Contacts www.tyco-fire.com Model FS Through F3S Mulsifyre Directional Spray Nozzles, Open, with Strainers High Velocity General Description The Model FS through F3S Mulsifyre Nozzles are open

More information

: 1250 gpm in the deck mode : 800 gpm while operating in the ground base - Dual Inlet : 1000 gpm while operating in the ground base - Single Inlet

: 1250 gpm in the deck mode : 800 gpm while operating in the ground base - Dual Inlet : 1000 gpm while operating in the ground base - Single Inlet APOLLO HI-RISER MONITOR STYLE 3433/3431 INSTALLATION, OPERATING, AND MAINTENANCE INSTRUCTIONS The following is intended to provide the basic instructions for installation, operation and maintenance of

More information

In U.S./International Akron Brass Company P.O. Box 86 Wooster, OH PH: Fax:

In U.S./International Akron Brass Company P.O. Box 86 Wooster, OH PH: Fax: In U.S./International Akron Brass Company P.O. Box 86 Wooster, OH 44691 PH: 330.264.5678 Fax: 330.264.2944 Toll Free: 800.228.1161 Toll Free Fax: 800.531.7335 E-Mail: akroncare@idexcorp.com www.akronbrass.com

More information

STYLE 5148 MERCURYMASTER OSCILLATING NOZZLE INSTALLATION, OPERATING, AND MAINTENANCE INSTRUCTIONS

STYLE 5148 MERCURYMASTER OSCILLATING NOZZLE INSTALLATION, OPERATING, AND MAINTENANCE INSTRUCTIONS STYLE 5148 MERCURYMASTER OSCILLATING NOZZLE INSTALLATION, OPERATING, AND MAINTENANCE INSTRUCTIONS The following is intended to provide the basic instructions for installation, operation, and maintenance.

More information

1/2" AIR DRIVEN DIAPHRAGM PUMP

1/2 AIR DRIVEN DIAPHRAGM PUMP 1/2" DRIVEN DIAPHRAGM PUMP OPERATION AND SERVICE GUIDE O-1225D NOV. 2008 Page 1 of 6 Refer to Bulletin P-605, Parts List P-9151 DRIVEN, DOUBLE DIAPHRAGM PUMP MANUAL Congratulations on purchasing one of

More information

NOZZLES NOZZLES SPECIALTY SABERJET NOZZLES THE FIRST TRULY MULTI-PURPOSE NOZZLE

NOZZLES NOZZLES SPECIALTY SABERJET NOZZLES THE FIRST TRULY MULTI-PURPOSE NOZZLE NOZZLES COMBINATION CONSTANT GAL. PIERCING NOZZLES PLAYPIPES SELECTABLE GAL. SHUTOFFS SMOOTH BORE SPECIALTY /nozzles 1.800.323.0244 EDARLEY.COM/NOZZLES Shop NOZZLES AUTOMATIC SABERJET NOZZLES THE FIRST

More information

Darley Fire Storm Nozzle

Darley Fire Storm Nozzle Darley Fire Storm Nozzle Quality and Performance The new Fire Storm nozzle delivers the quality and performance you are looking for in a selectable nozzle with the value you expect from Darley. Choose

More information

Northern Pump A Division of McNally Industries, LLC

Northern Pump A Division of McNally Industries, LLC Operation & Maintenance Manual for Northern 4900 Injection Operation & Maintenance Manual For Northern 4900 Injection Northern Pump A Division of McNally Industries, LLC 340 West Benson Avenue Grantsburg,

More information

Non-Valved Unisex Coupling

Non-Valved Unisex Coupling SM64019 October 2010 Aerospace Group Conveyance Systems Division Applicable additional manuals: None Carter Brand Ground Fueling Equipment Maintenance Manual Non-Valved Unisex Coupling Model 64019 Model

More information

Operating Manual & Safety Instructions ProTorc Hydraulic Torque Wrench Model # PTLC - Please read in full before operating ProTorc Torque Wrench -

Operating Manual & Safety Instructions ProTorc Hydraulic Torque Wrench Model # PTLC - Please read in full before operating ProTorc Torque Wrench - Operating Manual & Safety Instructions ProTorc Hydraulic Torque Wrench Model # PTLC - Please read in full before operating ProTorc Torque Wrench - ProTorc Important Safety Instructions READ ALL INSTRUCTIONS

More information

Operation and Maintenance Manual http://www.torsionx.eu Use the MaxDrv Series Square Drive Torque Wrench Model.75, 1, 3, 5, 8, 10, 20, 25, 35, 50 to install and remove threaded fasteners requiring precise

More information

AA2BIC SERIES PRODUCT SERVICE MANUAL

AA2BIC SERIES PRODUCT SERVICE MANUAL TM AA2BIC SERIES PRODUCT SERVICE MANUAL Metric standards apply for all pumps covered by this manual with regard to mounting dimensions, external connections, bolts, bolt threads, plugs and bearings. WARNING

More information

Welker Adjustable Probe with Check Valve and Welker Automatic Insertion Probe with Check Valve

Welker Adjustable Probe with Check Valve and Welker Automatic Insertion Probe with Check Valve a Installation, Operation, & Maintenance Manual Welker Adjustable Probe with Check Valve and Welker Automatic Insertion Probe with Check Valve Models AP-3MI & AIP-3MI The information in this manual has

More information

Vickers. Overhaul Manual. Vane Pumps. Small and Large Series Combination Pumps VC(K)(S)-**-(*)*D*-6(1) VC(K)(S)-**-(*)-*-*D*-5(1)

Vickers. Overhaul Manual. Vane Pumps. Small and Large Series Combination Pumps VC(K)(S)-**-(*)*D*-6(1) VC(K)(S)-**-(*)-*-*D*-5(1) Overhaul Manual Vickers Vane Pumps Small and Large Series Combination Pumps VC(K)(S)-**-(*)*D*-6(1) VC(K)(S)-**-(*)-*-*D*-5(1) Revised 12/1/86 I-3150-S Table of Contents Section I. Introduction................................................................................

More information

Chapter 15. Fire Hose. Answer Key. Firefighter I

Chapter 15. Fire Hose. Answer Key. Firefighter I Chapter 15 Fire Hose Firefighter I Terms 1. Fire Hose A flexible, portable tube manufactured from water tight materials in 50 to 100 foot (15 to 30 m) lengths that is used to transport water from a source

More information

RediCoat by Nordson. Hopper and VBF Dolly Systems. Customer Product Manual Part A Issued 10/07

RediCoat by Nordson. Hopper and VBF Dolly Systems. Customer Product Manual Part A Issued 10/07 RediCoat by Nordson Hopper and VBF Dolly Systems Customer Product Manual Part 1082648A Issued 10/07 This document is subject to change without notice. Nordson Corporation Amherst, Ohio USA 2 Table of Contents

More information

STYLE 5148 MERCURYMASTER OSCILLATING NOZZLE INSTALLATION, OPERATING, AND MAINTENANCE INSTRUCTIONS

STYLE 5148 MERCURYMASTER OSCILLATING NOZZLE INSTALLATION, OPERATING, AND MAINTENANCE INSTRUCTIONS STYLE 5148 MERCURYMASTER OSCILLATING NOZZLE INSTALLATION, OPERATING, AND MAINTENANCE INSTRUCTIONS The following is intended to provide the basic instructions for installation, operation, and maintenance.

More information

OPERATORS MANUAL for Electric Pressure Washers

OPERATORS MANUAL for Electric Pressure Washers OPERATORS MANUAL for Electric Pressure Washers Basic Hand Carry 1500A Hand Carry Basic Cart C1000E Cart Electric Cart Electric Thank You... for selecting our products. Our personnel have proudly made every

More information

TECHNICAL REFERENCE CLEANING POWER GUIDELINES TANKJET TANK CLEANER OVERVIEW BY TANK DIAMETER OPTIMIZING TANK CLEANING OPERATIONS

TECHNICAL REFERENCE CLEANING POWER GUIDELINES TANKJET TANK CLEANER OVERVIEW BY TANK DIAMETER OPTIMIZING TANK CLEANING OPERATIONS OPTIMIZING TANK CLEANING OPERATIONS CLEANING POWER GUIDELINES Choosing a tank cleaner is based primarily on tank size and level of cleaning required. Understanding the definitions that follow will help

More information

Head to Head Demo Comparison Sheet

Head to Head Demo Comparison Sheet Head to Head Demo Comparison Sheet Task Force Tips Quadrafog and Thunderfog Selectable Gallonage Nozzle The purpose of this document is to encourage you to compare TFT products head to head, apples to

More information

Maintenance Information

Maintenance Information 45528270 Edition 1 June 2007 Barring Motor T480 Series Maintenance Information Save These Instructions WARNING Always wear eye protection when operating or performing maintenance on this Barring Motor.

More information

HOSES. nozzle BRASS QUICK SEWER NOZZLE TAPE WASHER HIGH PRESSURE HOSE TOOLS TURBO HIGHER PSI RATING. o rings WASH SOAP CHISELING FLUSHING BLASTING

HOSES. nozzle BRASS QUICK SEWER NOZZLE TAPE WASHER HIGH PRESSURE HOSE TOOLS TURBO HIGHER PSI RATING. o rings WASH SOAP CHISELING FLUSHING BLASTING PRESSURE WASHER CENTER CATALOG BRASS QUICK coupling HIGH PRESSURE HOSE o rings TAPE HOSES HIGHER PSI RATING WASHER TURBO nozzle TOOLS for the trade SEWER NOZZLE WASH SOAP CHISELING FLUSHING BLASTING brass

More information

Operation and Maintenance Manual Model.75,, 3, 5, 8, 0, 0, 5, 35, 50 http://www.torsionx.com Use the MaxDrv Series Square Drive Torque Wrench Model.75,, 3, 5, 8, 0, 0, 5, 35, 50 to install and remove threaded

More information

IBT Series Square Drive Torque Wrenches

IBT Series Square Drive Torque Wrenches IBT Series Square Drive Torque Wrenches Operation and Maintenance Manual Model.75, 1, 3, 5, 8, 10, 20, 25, 35, 50 http://www.torsionx.com Use the IBT Series Square Drive Torque Wrenches Model.75, 1, 3,

More information

MODEL VG08001 CONTENT PACKING LIST / TOOLS NEEDED PANEL DIMENSIONS FITTINGS / TECHNICAL DATA WALL/CORNER INSTALLATION CARE AND TROUBLE SHOOTING

MODEL VG08001 CONTENT PACKING LIST / TOOLS NEEDED PANEL DIMENSIONS FITTINGS / TECHNICAL DATA WALL/CORNER INSTALLATION CARE AND TROUBLE SHOOTING CONTENT PACKING LIST / TOOLS NEEDED PANEL DIMENSIONS FITTINGS / TECHNICAL DATA WALL/CORNER INSTALLATION CARE AND TROUBLE SHOOTING WARRANTY 1 PACKING LIST DESCRIPTION MODEL NUMBER - PANEL HOUSING 88057

More information

AKRON BRASS COMPANY PH ( ) FAX ( )

AKRON BRASS COMPANY PH ( ) FAX ( ) Mercury Monitors The Mercury Monitors are the newest innovation in firefighting equipment. These monitors are smaller than any other portable ground monitor so it can be quickly set up and left unmanned

More information

PRODUCT SERVICE MANUAL FOR CIG Lip Seal Double Pumps

PRODUCT SERVICE MANUAL FOR CIG Lip Seal Double Pumps PRODUCT SERVICE MANUAL FOR CIG Lip Seal Double Pumps WARNING The Imo General Installation Operation, Maintenance, and Troubleshooting Manual, (No. SRM00046), as well as all other component manuals supplied

More information

OPERATION AND MAINTENANCE MANUAL

OPERATION AND MAINTENANCE MANUAL WREN IBT SERIES HYDRAULIC TORQUE WRENCHES IBT SQUARE DRIVE SERIES OPERATION AND MAINTENANCE MANUAL FOR WREN Products: POINT 75, 1IBT, 3IBT, 5IBT, 8IBT, 10IBT, 20IBT, 25IBT, 35IBT, 50IBT SQUARE DRIVE HYDRAULIC

More information

INSTALLATION/OPERATION/MAINTENANCE INSTRUCTIONS FOR ARCHON MODELS WD2010L, WD2010, WD2010H WASHDOWN STATIONS. ARCHON Industries, Inc.

INSTALLATION/OPERATION/MAINTENANCE INSTRUCTIONS FOR ARCHON MODELS WD2010L, WD2010, WD2010H WASHDOWN STATIONS. ARCHON Industries, Inc. ARCHON Industries, Inc. Washdown Stations Models WD2010L, WD2010, WD2010H Installation / Operation / Maintenance Instructions 1 This manual has been prepared as an aid and guide for personnel involved

More information

Section H Spray Guns. Table of Contents

Section H Spray Guns. Table of Contents Section H Overview You re sure to find a solution for your cleaning and rinsing needs in our comprehensive line of hand-held spray guns. Options range from a gentle spray to a high-impact solid stream.

More information

TILLOTSON LTD., CLASH INDUSTRIAL ESTATE, TRALEE, CO. KERRY, IRELAND PHONE: FAX:

TILLOTSON LTD., CLASH INDUSTRIAL ESTATE, TRALEE, CO. KERRY, IRELAND PHONE: FAX: TILLOTSON LTD., CLASH INDUSTRIAL ESTATE, TRALEE, CO. KERRY, IRELAND PHONE: +353 66 7121911 FAX: +353 66 7124503 e-mail: sales@tillotson.ie HR SERIES SERVICE MANUAL INTRODUCTION Tillotson has developed

More information

DRUM BRAKE RIMS Periodic inspection of drum brake rims is necessary to determine indications of uneven or excessive wear. In general, brake rim failures other that regular wear are caused by brake linings

More information

INSIDE YOUR HOLLEY CARBURETOR FUEL INLET SYSTEM

INSIDE YOUR HOLLEY CARBURETOR FUEL INLET SYSTEM INSIDE YOUR HOLLEY CARBURETOR The carburetor is quite simply a fuel metering device that operates under the logical and straightforward laws of physics. It has evolved over the years from a very simple

More information

NOZZLES HANDLINE NOZZLES MASTER STREAM PIERCING NOZZLES PLAYPIPES

NOZZLES HANDLINE NOZZLES MASTER STREAM PIERCING NOZZLES PLAYPIPES NOZZLES HANDLINE NOZZLES MASTER STREAM PIERCING NOZZLES PLAYPIPES Shop DARLEY FIRE STORM NOZZLE DELIVERS QUALITY AND PERFORMANCE The new Fire Storm nozzle delivers the quality and performance you are looking

More information

NOZZLES NOZZLES DARLEY FIRE STORM NOZZLE DELIVERS QUALITY AND PERFORMANCE TURBOJET NOZZLES NEW LOW PRICE

NOZZLES NOZZLES DARLEY FIRE STORM NOZZLE DELIVERS QUALITY AND PERFORMANCE TURBOJET NOZZLES NEW LOW PRICE NOZZLES HANDLINE NOZZLES MASTER STREAM PIERCING NOZZLES /nozzles NOZZLES Shop PLAYPIPES DARLEY FIRE STORM NOZZLE DELIVERS QUALITY AND PERFORMANCE 1.800.323.0244 EDARLEY.COM/NOZZLES The new Fire Storm nozzle

More information

servicing the swivel

servicing the swivel servicing the swivel The swivel seals and bearings require periodic replacement. This document describes how to determine which service procedure to use to service the swivel assembly, part number 101110.

More information

Type EA-1 PROTECTOSPRAY Directional Spray Nozzles, Automatic, Medium Velocity General Description

Type EA-1 PROTECTOSPRAY Directional Spray Nozzles, Automatic, Medium Velocity General Description Worldwide Contacts www.tyco-fire.com Type EA-1 PROTECTOSPRAY Directional Spray Nozzles, Automatic, Medium Velocity General Description IMPORTANT Always refer to Technical Data Sheet TFP700 for the INSTALLER

More information

OPERATING AND MAINTENANCE MANUAL

OPERATING AND MAINTENANCE MANUAL Series 2200 Series 2220 Engineered Performance TABLE OF CONTENTS INTRODUCTION 1 About the Series 2200/ 2220 Valve 1 Identifying the valves 1 1.0 VALVE INSTALLATION AND START-UP 2 2 0 VALVE MAINTENANCE

More information

Industrial Electric Monitors. Industrial

Industrial Electric Monitors. Industrial Industrial Electric Monitors Corrosion resistant monitors with maximum travel for optimal coverage in industrial, mining and marine environments. Severe-Duty Monitor 750 GPM (2900 LPM) The Severe-Duty,

More information

Data Sheet 11.1 Issue A

Data Sheet 11.1 Issue A TECHNICAL DATA : MODEL A & B Data Sheet 11.1 Page 1 of 6 MAXIMUM WORKING PRESSURE MINIMUM EFFECTIVE WORKING PRESSURE END CONNECTION MATERIAL 12.3 Kg./Sq.Cm. (175 psi) 7 Kg./Sq.Cm. (100 psi) maximum 1.4

More information

GUNS & LANCES. Linear Trigger Guns. Legacy Best Trigger Guns. Legacy Industrial Trigger Guns. Giant Trigger Guns. PA Trigger Guns.

GUNS & LANCES. Linear Trigger Guns. Legacy Best Trigger Guns. Legacy Industrial Trigger Guns. Giant Trigger Guns. PA Trigger Guns. Legacy Best Trigger Guns The most comfortable and longest lasting gun on the market!!! Weight: 21 oz Ideal for commercial cleaning & long work time applications. Quantity price breaks at 10 and 25 guns

More information

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL INSTALLATION, OPERATION, AND MAINTENANCE MANUAL MODEL 4D-200 REDUCED PRESSURE PRINCIPLE (RPZ) & MODEL 4D-700 REDUCED PRESSURE DETECTOR ASSEMBLY (RPDA) BACKFLOW PREVENTERS 2 ½ 10 Conbraco Industries Inc.

More information

Your One Stop Shop for Parts GUNS & LANCES

Your One Stop Shop for Parts GUNS & LANCES Your One Stop Shop for Parts 7 Legacy AP1000 Trigger Guns The World s most popular and easiest to repair trigger gun!!! PSI: 4500 Weight: 19 oz 9.802-229.0 353010 AP1000 8.710-414.0 353010W AP1000 Weep

More information

Operation & Maintenance Manual For 4900 Series Pumps Bulletin 134

Operation & Maintenance Manual For 4900 Series Pumps Bulletin 134 For 340 West Benson Avenue Grantsburg, WI 54840 1-800-366-1410 715-463-5177 www.northern-pump.com Table of Contents Introduction... 3 Cautionary Statements... 5 Pump Installation... 6 Removal from Installation...

More information

GUNS & LANCES. Legacy AP1000 Trigger Guns. MV 920 Gun. Linear Trigger Guns. M407 Trigger Gun. Giant Trigger Guns. Your One Stop Shop for Parts

GUNS & LANCES. Legacy AP1000 Trigger Guns. MV 920 Gun. Linear Trigger Guns. M407 Trigger Gun. Giant Trigger Guns. Your One Stop Shop for Parts Legacy AP1000 Trigger Guns The World s most popular and easiest to repair trigger gun!!! PSI: 4500 Weight: 19 oz 9.802-229.0 353010 AP1000 8.710-414.0 353010W AP1000 Weep 8.704-157.0 109856 Unitized Valve

More information

DIRECT-DRIVE PRESSURE WASHERS

DIRECT-DRIVE PRESSURE WASHERS DIRECT-DRIVE PRESSURE WASHERS PJG SERIES PRESSURE WASHER MANUFACTURED BY: PJG-2001 PJG-2501-6.5 PJG-2501 PJG-3000 PJG-3001 PJG-3501 PJG-4001 OPERATOR s INTRODUCTION Thank you for purchasing a Mancorp Pressure

More information

Medium and high pressure pumps

Medium and high pressure pumps Screw pumps Medium and high pressure pumps Installation and Start-up Instruction This instruction is valid for all standard high pressure pumps: E4, D4 and D6 Contents Page Pump identification 2 Installation

More information

Swivel Quick Disconnect To Mate Various Carter Brand Nozzles. Model SM Maintenance & Repair Manual

Swivel Quick Disconnect To Mate Various Carter Brand Nozzles. Model SM Maintenance & Repair Manual Aerospace Group Conveyance Systems Division Carter Brand Ground Fueling Equipment SM44315 February 1998 Applicable additional manuals: SM61428 Nozzle SM64348 Nozzle SM64200 Nozzle Maintenance & Repair

More information

QUALITY MISTING PUMPS

QUALITY MISTING PUMPS DIRECT DRIVE TOTALLY ENCLOSED FAN COOLED 60200KH, 60201KH MISTING PUMP MANUAL INCLUDING: SPECIFICATION DATA, GENERAL SAFETY PRECAUTIONS, OPERATION, INSTALLATION, PARTS, MAINTENANCE & WARRANTY QUALITY MISTING

More information

ENGINE MEASUREMENTS ENGINE MEASUREMENTS AND SPECIFICATIONS CYLINDER HEAD. Measure Cylinder Compression. Using Telescoping Gauges and Hole Gauges

ENGINE MEASUREMENTS ENGINE MEASUREMENTS AND SPECIFICATIONS CYLINDER HEAD. Measure Cylinder Compression. Using Telescoping Gauges and Hole Gauges ENGINE MEASUREMENTS AND SPECIFICATIONS Tool List Qty. Required Compression Gauge, 20 kgf/cm²: E-Z-GO Part No. N/A... 1 Compression Gauge Adapter, M14 1.25: E-Z-GO Part No. N/A... 1 Valve Seat Cutter, 45-35

More information

Daikin Steam Coils. Installation and Maintenance Manual IM 901. Types HI-F5, HI-F8, & E-F5. Group: Applied Air. Part Number: IM 901

Daikin Steam Coils. Installation and Maintenance Manual IM 901. Types HI-F5, HI-F8, & E-F5. Group: Applied Air. Part Number: IM 901 Installation and Maintenance Manual IM 901 Daikin Steam Coils Group: Applied Air Part Number: IM 901 Date: February 2008 Types HI-F5, HI-F8, & E-F5 2008 Daikin Applied Contents Introduction... 3 General

More information

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Contents Section 1. General Observations... 2 2. Operation... 4 3. Control During Operation... 5 4. Trouble Shooting... 6 5. Maintenance... 7 Please

More information

INSTRUCTION MANUAL AND PARTS LIST FOR PG/RG3D_-187, 218, 250 and 312 SERIES PUMPS

INSTRUCTION MANUAL AND PARTS LIST FOR PG/RG3D_-187, 218, 250 and 312 SERIES PUMPS INSTRUCTION MANUAL AND PARTS LIST FOR PG/RG3D_-187, 218, 250 and 312 SERIES PUMPS WARNING This Instruction Manual and General Instructions Manual, CA-1, should be read thoroughly prior to pump installation,

More information

Hollow Cone Spray Nozzles Series

Hollow Cone Spray Nozzles Series Hollow Cone Spray Nozzles Series TANK WASHING HOLLOW CONE APPLICATION Absorption Chemical process engineering Cooling Disinfection Desuperheating Dust control Fire protection Foam destruction Gas treatment

More information

Car Wash / Pressure Washer

Car Wash / Pressure Washer Car Wash / Pressure Washer PARTS & ACCESSORIES Proudly distributed by: We have many representatives in all 50 states. Give us a call to locate the one nearest you! Custom manufacturing available... ask

More information

CFHN SERIES PRODUCT SERVICE MANUAL

CFHN SERIES PRODUCT SERVICE MANUAL CFHN SERIES PRODUCT SERVICE MANUAL Metric standards apply for all pumps covered by this manual with regard to Mounting dimensions, external connections, bolts, bolt threads, plugs and bearings. WARNING

More information

Operating & Maintenance Manual For Steam Conditioning Valve

Operating & Maintenance Manual For Steam Conditioning Valve For Steam Conditioning Valve 1 Table of Contents 1.0 Introduction 3 2.0 Product description 3 3.0 Safety Instruction 4 4.0 Installation and Commissioning 5 5.0 Valve Disassembly 6 6.0 Maintenance 6 7.0

More information

SECTION 8 Fire Protection

SECTION 8 Fire Protection Bronze Wet Barrel Fire Hydrants With over 100 years of experience on the west coast the heart of the wet barrel market James Jones Company, LLC is the innovator in the bronze wet barrel hydrant industry.

More information

GREEN GARDE MODEL JD9-C - HIGH PRESSURE SPRAY GUN

GREEN GARDE MODEL JD9-C - HIGH PRESSURE SPRAY GUN GREEN GARDE MODEL JD9-C - HIGH PRESSURE SPRAY GUN Guns Spray 38500 Model JD9-C - 38500 The JD9 heavy-duty spray gun can help make your operation more effective and profitable. Check these advantages. Adjustable

More information

ST21A Metal Repair. Copyright 1998 Inter-Industry Conference On Auto Collision Repair v.4.0

ST21A Metal Repair. Copyright 1998 Inter-Industry Conference On Auto Collision Repair v.4.0 Uniform Procedures For Collision Repair ST21A Metal Repair 1. Description This procedure describes repair methods and inspection requirements for straightening damaged aluminum. 2. Purpose The purpose

More information

Injector. General Information CAUTION. Use only the specified injector for the engine.

Injector. General Information CAUTION. Use only the specified injector for the engine. Page 1 of 32 006-026 Injector General Information CAUTION Use only the specified injector for the engine. All engines use closed nozzle, hole-type injectors. However, the injectors can have different part

More information

HydroWhirl Orbitor 100

HydroWhirl Orbitor 100 HydroWhirl Orbitor 100 Tank Washing Machine Instruction and Maintenance Manual BETE Fog Nozzle Inc. www.bete.com HydroWhirl Orbitor 100 Page 2 of 40 Contents Introduction to the Orbitor 100 Tank Washing

More information

TECHNICAL SERVICE MANUAL

TECHNICAL SERVICE MANUAL Electronic copies of the most current TSM issue can be found on the Viking Pump website at www.vikingpump.com TECHNICAL SERVICE MANUAL HEAVY-DUTY Stainless steel BRACKET MOUNTED PUMPS SERIES 127 AND 4127

More information

REAR MOUNT AERIAL LADDER USED AS A WATER TOWER

REAR MOUNT AERIAL LADDER USED AS A WATER TOWER EVOLUTION 21A January 1, 1997 REAR MOUNT AERIAL LADDER USED AS A WATER TOWER 1. EQUIPMENT: 2. COMMAND: 1 Rear Mount Aerial Ladder 1 Portable Ladder Pipe (Note B) 1 Halyard and Reel (Note C) 1 Siamese 3"

More information

K-BALL SERIES SPRAY NOZZLES

K-BALL SERIES SPRAY NOZZLES K-BALL SERIES NOZZLES K-Ball Clip-on spray nozzles CHARACTERISTICS: These nozzles simply clip over a pre-drilled pipe (9/16 dia. hole) and are available with a variety of spray balls, in various spray

More information

SECTION 7 - SUSPENSION

SECTION 7 - SUSPENSION For Arctic Cat Discount Parts Call 606-678-9623 or 606-561-4983 SECTION 7 - SUSPENSION 7 TABLE OF CONTENTS Front and Rear Suspension Assembly Schematics... 7-2 Shock Absorbers... 7-2 Swing Arm... 7-5 Front

More information

GENERAL GUIDELINES FOR THE APPLICATION OF TECTYL AUTO/TRUCK/TRAILER RUSTPROOFING COMPOUNDS

GENERAL GUIDELINES FOR THE APPLICATION OF TECTYL AUTO/TRUCK/TRAILER RUSTPROOFING COMPOUNDS Number 17 GENERAL GUIDELINES FOR THE APPLICATION OF TECTYL AUTO/TRUCK/TRAILER RUSTPROOFING COMPOUNDS A. Equipment 1) Airless type spray equipment, designed for fluid pressure atomization. The spray gun

More information

HexPro Series Low Profile Wrenches

HexPro Series Low Profile Wrenches HexPro Series Low Profile Wrenches Operation and Maintenance Manual Model 2HP 4HP 8HP 14HP 30HP www.torquetoolsinc.com Use the HEXPRO Series Low Profile Wrenches Model 2HP 4HP 8HP 14HP 30HP to install

More information

Powered Industrial Truck Safety Program

Powered Industrial Truck Safety Program Powered Industrial Truck Safety Program 0 TABLE OF CONTENTS Forklift Safety Program 1.0 Overview.. 2 2.0 Purpose....2 3.0 Procedures..2 4.0 Responsibilities. 4 5.0 Training Requirements......5 Appendix

More information

NOZZLE TYPES AND CHARACTERISTICS

NOZZLE TYPES AND CHARACTERISTICS 95 NOZZLE TYPES AND CHARACTERISTICS Dennis w. Bintner Design Engineer Delavan Hanufacturing Company West Des Moines, Iowa The many varieties of herbicides on the market today, make the proper selection

More information

Color-Coded Polymer Pistol Grip, Valve Handle Covers offer rugged durability in harsh fi refi ghting conditions

Color-Coded Polymer Pistol Grip, Valve Handle Covers offer rugged durability in harsh fi refi ghting conditions Domestic Catalog G-Force Nozzles: The Inside Story Based on a highly customizable global nozzle platform design, the unique G-Force series of fi xed, selectable, and automatic nozzles combine over 40 years

More information

CROSBY SERIES 800 AND 900 OMNI-TRIM PRESSURE RELIEF VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

CROSBY SERIES 800 AND 900 OMNI-TRIM PRESSURE RELIEF VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS any and all liability arising out of the same. Any installation, maintenance, adjustment, repair and testing performed on pressure relief valves should be done in accordance with the requirements of all

More information

1½ Diameter Aluminum Pipe. Standard 2 1/2 shut-off with 1 1/8 MST T-handle allows members control of the nozzle.

1½ Diameter Aluminum Pipe. Standard 2 1/2 shut-off with 1 1/8 MST T-handle allows members control of the nozzle. T.B. TOOLS 7 DATA SHEET 17 1. DESCRIPTION FDNY Designation Material Weight Misc. High Rise Nozzle 1½ Diameter Aluminum Pipe Approx 10 lbs Standard 2 1/2 shut-off with 1 1/8 MST T-handle allows members

More information

2. Hydraulic Valves, Actuators and Accessories. 24 Marks

2. Hydraulic Valves, Actuators and Accessories. 24 Marks 2. Hydraulic Valves, Actuators and Accessories 24 Marks Co related to chapter 602.2 Describe working principle of various components used in hydraulic & pneumatic systems. 602.3 Choose valves, actuators

More information

Maintenance Information

Maintenance Information 16572554 Edition 2 May 2014 Air Drill 44SMA, 44SMA-EU Maintenance Information Save These Instructions Product Safety Information WARNING Failure to observe the following warnings, and to avoid these potentially

More information