Chapter Quiz. Directions: Write the correct letter on the blank before each question.

Size: px
Start display at page:

Download "Chapter Quiz. Directions: Write the correct letter on the blank before each question."

Transcription

1 Chapter 12 Quiz Name: Date: Directions: Write the correct letter on the blank before each question. Objective 1: Describe dry-barrel and wet-barrel hydrants. 1. Most fire hydrants are made of: (605) A. PVC. B. steel. C. bronze. D. cast iron. 2. Closing a hydrant too fast may cause a sudden increase in water pressure called: (605) A. water surge. B. water hammer. C. pressure growth. D. pressure increase. 3. Which type of hydrant is installed in areas where prolonged periods of subfreezing weather are common? (605) A. Dry-barrel B. Wet-barrel C. Open-barrel D. Closed-barrel 4. Which type of hydrant is usually installed in warmer climates where prolonged periods of subfreezing weather are uncommon? (607) A. Dry-barrel B. Wet-barrel C. Open-barrel D. Closed-barrel Oklahoma State University 12-1

2 5. Which type of hydrant has a horizontal compression-type valve at each outlet? (607) A. Dry-barrel B. Wet-barrel C. Open-barrel D. Closed-barrel 6. Which type of hydrant has a main valve located below the frost line that prevents water from entering the hydrant barrel? ( ) A. Dry-barrel B. Wet-barrel C. Open-barrel D. Closed-barrel 7. The hydrant barrel of a dry-barrel hydrant is usually from the top of the stem down to the main valve. (606) A. open B. closed C. empty D. filled with water 8. When a dry-barrel hydrant is closed after use, the remaining water empties through a: (606) A. drain hole. B. drain plug. C. gate valve. D. butterfly valve. 9. When ensuring that a dry-barrel hydrant is draining correctly, close the main valve by turning the step nut clockwise until resistance is felt, then turn it counterclockwise. (607) A. a quarter-turn B. a full-turn C. two turns C. three turns Oklahoma State University 12-2

3 Objective 2: Discuss fire hydrant marking and location. 10. According to the NFPA (609), orange fire hydrants indicate a flow of: A. less than 500 gpm (1 900 L/min). B. 500 to 999 gpm (1 900 L/min to L/min). C. 1,000 to 1,499 gpm (3 785 L/min to L/min). D. 1,500 gpm (5 680 L/min) or greater. 11. According to the NFPA, hydrants indicate a flow of less than 500 gpm (1 900 L/min). (609) A. red B. green C. orange D. light blue 12. According to the NFPA, hydrants indicate a flow of 1,000 to 1,499 gpm (3 785 L/min to L/min). (609) A. red B. green C. orange D. light blue 13. According to the NFPA, light blue hydrants indicate a flow of: (609) A. less than 500 gpm (1 900 L/min). B. 500 to 999 gpm (1 900 L/min to L/min). C. 1,000 to 1,499 gpm (3 785 L/min to L/min). D. 1,500 gpm (5 680 L/min) or greater. 14. Decisions regarding location, spacing, and distribution of fire hydrants are usually made by: (607) A. contractors. B. fire inspectors. C. fire department personnel. D. water department personnel. Oklahoma State University 12-3

4 15. In general, hydrants should not be spaced more than feet (m) apart in high-value districts. (607) A. 100 (30) B. 200 (60) C. 300 (100) D. 400 (120) 16. A basic rule is to locate a hydrant at intersection. (607) A. every B. every other C. every third D. every fifth Intermediate hydrants may be required where distances between intersections exceed feet (m). ( ) A. 50 to 100 (15 to 30) B. 250 to 300 (75 to 100) C. 350 to 400 (105 to 120) D. 450 to 500 (135 to 150) Which of the following is NOT a factor affecting hydrant location and spacing? (608) A. Building densities B. Types of construction C. Types of occupancies D. Amount of pedestrian traffic Objective 3: Summarize potential problems to look for when inspecting fire hydrants. 19. Hydrant testing and inspections are the responsibility of: (608) A. NFPA. B. fire department personnel. C. Underwriters Laboratories (UL). D. street department personnel. Oklahoma State University 12-4

5 20. Which of the following is NOT something to look for when inspecting fire hydrants? ( ) A. Painted hydrants B. Missing outlet caps C. Outlets that face the wrong direction D. Insufficient distances between buildings and hydrants Objective 4: Explain the process of fire hydrant testing Which of the following statements about fire hydrant testing is MOST accurate? (609) A. Fire hydrants should be tested on a monthly basis. B. Fire hydrants should be tested on a quarterly basis. C. Fire hydrant testing is always performed by the fire department. D. Many departments are no longer responsible for the testing of hydrants. When conducting a flow test on a hydrant, remove outlet cap(s). (609) A. one B. two C. three D. all After inspecting outlet caps during a flow test, replace all caps except: (609) A. the top outlet cap. B. one 2½-inch (65 mm) cap. C. two 2½-inch (65 mm) caps. D. the outlet cap closest to the pumper. During a flow test, a cap-type pressure gauge should be connected to: (609) A. the pumper. B. the hose nozzle. C. the hydrant to be tested. D. a second hydrant nearby. Oklahoma State University 12-5

6 25. During a flow test, the test hydrant should be turned on to pressure. (610) A. one-quarter B. half C. three-quarter D. full 26. Residual pressure should be recorded from: (610) A. the pumper. B. the hose nozzle. C. the second hydrant. D. the hydrant to be tested. Objective 5: Discuss alternative water supplies. 27. Which of the following is NOT an alternative water supply source? (610) A. Lakes B. Ponds C. Swimming pools D. Water treatment plants 28. Which of the following is the definition of drafting? (610) A. Drawing water from a pumper to supply a hoseline B. Drawing water from a static source to supply a pumper C. Drawing water from a portable tank to supply a hydrant D. Drawing water from a static source to supply a hydrant 29. A minimum of inches (mm) of water above and below a hard intake strainer is usually needed for it to function properly. (611) A. 12 (300) B. 24 (600) C. 36 (900) D. 48 (1 200) Oklahoma State University 12-6

7 Which kind of strainers can draft water from more shallow sources? (611) A. Intake B. Drafting C. Floating D. Underground Dry hydrants are installed at to increase the water supply available for firefighting. (611) A. static water sources B. water treatment plants C. residential swimming pools D. wastewater treatment facilities 32. Dry hydrants are constructed of: (611) A. copper. B. cast iron. C. aluminum. D. steel or PVC pipe. 33. Dry hydrants are designed to supply at least gpm (L/min). (611) A. 500 (2 000) B. 1,000 (4 000) C. 1,500 (6 000) D. 2,000 (8 000) Objective 6: Discuss rural water supply operations. 34. Which of the following is the definition of a water shuttle? (612) A. Drawing water from a pumper to supply a hoseline B. Drawing water from a static source to supply a pumper C. Hauling water from a portable tank to the fire D. Hauling water from a supply source to portable tanks Oklahoma State University 12-7

8 Water shuttles are recommended for distances greater than mile(s) (km) or greater than the fire department s capability of laying supply hoselines. (612) A. ½ (0.8) B. 1 (1.6) C. 1½ (2.4) D. 2 (3.2) Which of the following is NOT a critical element of a water shuttle? (612) A. Traffic control B. Hydrant operations C. Fast-fill and fast-dump capabilities D. An Incident Commander at both fill and dump sites Which of the following is NOT a key component of a water shuttle? (612) A. Fill apparatus at the fill site B. Vacuum tankers at the fill site C. Attack apparatus at the dump site D. Water tenders to haul water from the fill site to the dump site 38. The dump site of a water shuttle is generally located: (612) A. near the fire or incident. B. near the static water source. C. as close to the station as possible. D. between the fill site and dump site 39. Portable tanks range from gallons (L) upward. (613) A. 250 (1 000) B. 500 (2 000) C. 750 (3 000) D. 1,000 (4 000) 40. Portable tanks may use to transfer water from one tank to another. (613) A. drain fittings B. discharge lines C. hard sleeve hose D. jet siphon devices Oklahoma State University 12-8

9 41. Which of the following is NOT a way in which water tenders unload? (615) A. Jet dumps B. Relay pumps C. Apparatus-mounted pumps D. Gravity dumping through large dump valves 42. According to NFPA 1901, water tenders on level ground should be capable of dumping or filling at rates of at least gpm (L/min). (615) A. 250 (1 000) B. 500 (2 000) C. 750 (3 000) D. 1,000 (4 000) Which of the following may be used when the water source is close enough to the fire scene that water shuttles are not necessary? (616) A. Relay pumping B. Water shuttles C. Gravity dumps D. Jet siphon devices Which of the following is NOT a factor in determining how many pumpers are needed for a relay? (616) A. Size of hose available B. Volume of water needed C. Amount of hose available D. Distance between the station and the fire scene 45. Which apparatus should be located at the water source? (616) A. Apparatus with largest gravity dump B. Apparatus with largest portable tank C. Apparatus from nearest fire department D. Apparatus with greatest pumping capacity Oklahoma State University 12-9

TWO FULLY EQUIPPED PUMPERS STATIC AND PRESSURIZED WATER SOURCES REFERENCES: ESSENTIALS OF FIRE FIGHTING, FOURTH EDITION, IFSTA, CHAPTERS 11 AND 12

TWO FULLY EQUIPPED PUMPERS STATIC AND PRESSURIZED WATER SOURCES REFERENCES: ESSENTIALS OF FIRE FIGHTING, FOURTH EDITION, IFSTA, CHAPTERS 11 AND 12 INSTRUCTOR GUIDE TOPIC: BACK TO BASICS: ESTABLISHING SUPPLY LINES TIME REQUIRED: THREE HOURS MATERIALS: TWO FULLY EQUIPPED PUMPERS STATIC AND PRESSURIZED WATER SOURCES REFERENCES: ESSENTIALS OF FIRE FIGHTING,

More information

AIDS LESSON PLAN INSTRUCTOR NOTES INSTRUCTOR GUIDE. Course: Tanker operations in water supply

AIDS LESSON PLAN INSTRUCTOR NOTES INSTRUCTOR GUIDE. Course: Tanker operations in water supply AIDS LESSON PLAN INSTRUCTOR NOTES INSTRUCTOR GUIDE Course: Tanker operations in water supply Session Reference: 1-1 Level of instruction: Time Required: 3 Hours Materials Required: Engines, tankers, various

More information

Tyger Drafting Eductors

Tyger Drafting Eductors - Tyger Drafting Eductors Pump it dry DRAFT USING SOFT HOSE! VITA MOTIVATOR P.O. Box 8139 Englewood, NJ 07631 201-567-1151 : fax 201-734-8482 michaels.greene@att.net t Tyger Drafting Tyger Eductor Drafting

More information

Pumping Apparatus Driver/Operator Types of Apparatus Equipped with a Pump. Chapter Test

Pumping Apparatus Driver/Operator Types of Apparatus Equipped with a Pump. Chapter Test Chapter 1 Test Name: Date: Directions: Write the correct letter on the blank before each question. Objective 1: Describe fire department pumpers. 1. The main purpose of fire department pumpers is to: (13)

More information

STANDARD OPERATING GUIDELINES BELMONT COUNTY TANKER TASK FORCE

STANDARD OPERATING GUIDELINES BELMONT COUNTY TANKER TASK FORCE ACTIVATION OF TANKER TASK FORCE PROCEDURE: THROUGH PREDETERMINED AUTOMATIC AID RESPONSE OR THROUGH A REQUEST BY A HOST INCIDENT COMMANDER WHO NOTIES BELMONT COUNTY CENTRAL DISPATCH THAT THE IS REQUESTED

More information

New Windsor, Maryland Rural Water Supply Drill. Tanker Shuttle Drill May 23, 2009 Summary Report

New Windsor, Maryland Rural Water Supply Drill. Tanker Shuttle Drill May 23, 2009 Summary Report New Windsor, Maryland Rural Water Supply Drill Tanker Shuttle Drill May 23, 2009 Summary Report Overview On May 23, 2009, the New Windsor VFC of Carroll County, Maryland hosted a rural water supply drill.

More information

ESCONDIDO FIRE DEPARTMENT TRAINING MANUAL ENGINE MODULE HOSE PAGE 1 OF 20 Supply Hose Lays Revised

ESCONDIDO FIRE DEPARTMENT TRAINING MANUAL ENGINE MODULE HOSE PAGE 1 OF 20 Supply Hose Lays Revised HOSE 12-01-16 PAGE 1 OF 20 There are five base North Zone supply hose lays: Forward Lay Spotting a Hydrant Stationary Lay Reverse Lay Split Lay Escondido Fire Department Core Hose Lays The Escondido Fire

More information

Rural Water Supply Operations Seminar & Drill

Rural Water Supply Operations Seminar & Drill Colton, New York Rural Water Supply Operations Seminar & Drill 75-min Tanker Shuttle Drill August 24, 2008 Summary Report Overview In August of 2008 the Colton Fire District, in conjunction with the Pierrepont

More information

ADO-Pumping Apparatus Manipulative Skill Objectives PREVENTIVE MAINTENANCE

ADO-Pumping Apparatus Manipulative Skill Objectives PREVENTIVE MAINTENANCE ADO-Pumping Apparatus Manipulative Skill Objectives PREVENTIVE MAINTENANCE 1. Perform and document routine tests, inspections, and servicing functions on specified systems and components. A. For a fire

More information

LEVEL 2 DEFENSIVE Standard Equipment Guide

LEVEL 2 DEFENSIVE Standard Equipment Guide LEVEL 2 DEFENSIVE Standard Guide This guidance document was developed to assist NWT fire departments with identifying the minimum equipment required for a Standard - Level 2 Defensive fire service as defined

More information

Gaining Access. Exploring and alternative to drafting

Gaining Access. Exploring and alternative to drafting Slide 1 Rural Fire Command by Larry Davis Installment 32 July 2005 Gaining Access Exploring and alternative to drafting 1 Slide 2 Training America s Rural Fire & Emergency Responders A Message the Author,

More information

Water Supply for Suburban and Rural Firefighting, First Edition Final Version December 2012

Water Supply for Suburban and Rural Firefighting, First Edition Final Version December 2012 1 ACKNOWLEDGEMENTS The Water Supply for Suburban and Rural Firefighting, First Edition, manual was developed through a cooperative effort of the following Northern Virginia fire departments: Arlington

More information

MEDALLION HYDRANT. clowvalve.com AWWA C502 UL LISTED FM APPROVED NSF 61/372 CERTIFIED 250 PSI WORKING PRESSURE 10-YEAR LIMITED WARRANTY

MEDALLION HYDRANT. clowvalve.com AWWA C502 UL LISTED FM APPROVED NSF 61/372 CERTIFIED 250 PSI WORKING PRESSURE 10-YEAR LIMITED WARRANTY clowvalve.com MEDALLION HYDRANT AWWA C50 UL LISTED FM APPROVED NSF 6/37 CERTIFIED 50 PSI WORKING PRESSURE 0-YEAR LIMITED WARRANTY Clow Valve, A Division of McWane, Inc. MEDALLION HYDRANT FIRE PROTECTION

More information

ADO Mobile Water Supply Apparatus Manipulative Skill Objectives PREVENTIVE MAINTENANCE

ADO Mobile Water Supply Apparatus Manipulative Skill Objectives PREVENTIVE MAINTENANCE ADO Mobile Water Supply Apparatus Manipulative Skill Objectives PREVENTIVE MAINTENANCE 1. Perform and document routine tests, inspections, and servicing functions on specified systems and components. NFPA

More information

ADMIRAL HYDRANT. clowvalve.com

ADMIRAL HYDRANT. clowvalve.com clowvalve.com ADMIRAL HYDRANT AWWA C502 UL LISTED FM APPROVED NSF 61/372 CERTIFIED 250 PSI WORKING PRESSURE 350 PSI WORKING PRESSURE AVAILABLE 10-YEAR LIMITED WARRANTY Clow Valve, A Division of McWane,

More information

NORTH COUNTY FIRE AUTHORITY POLICY & PROCEDURE MANUAL OPERATIONS

NORTH COUNTY FIRE AUTHORITY POLICY & PROCEDURE MANUAL OPERATIONS PURPOSE: This policy and procedure describes the actions to be taken in the event of an emergency resulting from a fire, explosion, spill, or any unplanned sudden or non sudden release of hazardous waste

More information

AVK SAUDI VALVES MANUFACTURING COMPANY

AVK SAUDI VALVES MANUFACTURING COMPANY AVK SAUDI VALVES MANUFACTURING COMPANY AVK SERIES 24 - HIGH PRESSURE, WET BARREL HYDRANT FIELD MAINTENANCE AND INSTRUCTION MANUAL TABLE OF CONTENTS EXPLODED ASSEMBLY / PARTS LIST INTRODUCTION / DESCRIPTION

More information

NMSU FIRE DEPARTMENT FIRE PUMP ACCEPTANCE TEST

NMSU FIRE DEPARTMENT FIRE PUMP ACCEPTANCE TEST Date Documents Submitted: Log No.: File No.: Plan Examiner: Permit No.: Property Information Building Name: Building Address: Building Manager's Name: Building Manager's Phone: Fax: System Designer/Contractor

More information

mh-valve.com 129 HYDRANT AWWA C502 NSF 61/372 CERTIFIED UL LISTED FM APPROVED 250 PSI WORKING PRESSURE 10-YEAR LIMITED WARRANTY

mh-valve.com 129 HYDRANT AWWA C502 NSF 61/372 CERTIFIED UL LISTED FM APPROVED 250 PSI WORKING PRESSURE 10-YEAR LIMITED WARRANTY mh-valve.com 129 HYDRANT AWWA C502 NSF 61/372 CERTIFIED UL LISTED FM APPROVED 250 PSI WORKING PRESSURE 10-YEAR LIMITED WARRANTY 129 HYDRANT YESTERDAY, TODAY, & TOMORROW For more than 85 years, the M&H

More information

STANDARD LEVEL 2 DEFENSIVE Standard Firefighter Training I Minimum Equipment List

STANDARD LEVEL 2 DEFENSIVE Standard Firefighter Training I Minimum Equipment List STANDARD LEVEL 2 DEFENSIVE Standard Firefighter Training I Minimum Equipment List The NWT has established recommended operational service levels which may be further broken down into sections to fit local

More information

Dispatching Apparatus and Personnel

Dispatching Apparatus and Personnel Page: 1 of 5 Dispatching Apparatus and Personnel Table of Contents Page 1.0 Purpose 2 2.0 Responsibilities 2 3.0 Definitions 2 4.0 Requirement 2 5.0 Dispatching Apparatus 2 6.0 Inside the Taylors Bridge

More information

Lakes Region Mutual Fire Aid, New Hampshire Rural Water Supply Operations Seminar & Drill. Tanker Shuttle Drill May 17, 2009 Summary Report

Lakes Region Mutual Fire Aid, New Hampshire Rural Water Supply Operations Seminar & Drill. Tanker Shuttle Drill May 17, 2009 Summary Report Lakes Region Mutual Fire Aid, New Hampshire Rural Water Supply Operations Seminar & Drill Tanker Shuttle Drill May 17, 2009 Summary Report Overview In May 2009, the Lakes Region Mutual Fire Aid Association

More information

PENNSYLVANIA STATE FIRE ACADEMY PUMPER - DRIVER/OPERATOR (PDO) SKILL STATIONS. Pumper -Driver / Operator (PDO) Skill Stations

PENNSYLVANIA STATE FIRE ACADEMY PUMPER - DRIVER/OPERATOR (PDO) SKILL STATIONS. Pumper -Driver / Operator (PDO) Skill Stations Pumper -Driver / Operator (PDO) Skill Stations NFPA 1002 - Chapters 4 and 5 (2017 Edition) Station A Preventive Maintenance Mandatory Station Station B Driving on Public Roadways Mandatory Station Station

More information

Second Revision No. 7-NFPA [ Section No. 2.4 ] Submitter Information Verification. Committee Statement 9/17/2015 2:57 PM

Second Revision No. 7-NFPA [ Section No. 2.4 ] Submitter Information Verification. Committee Statement 9/17/2015 2:57 PM Second Revision No. 7-NFPA 1142-2015 [ Section No. 2.4 ] 2.4 References for Extracts in Mandatory Sections. NFPA 1, Fire Code, 2015 edition. NFPA 13D, Standard for the Installation of Sprinkler Systems

More information

Chapter 15. Fire Hose. Answer Key. Firefighter I

Chapter 15. Fire Hose. Answer Key. Firefighter I Chapter 15 Fire Hose Firefighter I Terms 1. Fire Hose A flexible, portable tube manufactured from water tight materials in 50 to 100 foot (15 to 30 m) lengths that is used to transport water from a source

More information

Driver/Operator Program Part III - Tanker

Driver/Operator Program Part III - Tanker Driver/Operator Program Part III - Tanker Overview The Driver/Operator Preparation Program Part II is designed to standardize the training and release of driver/operators within the company; the intent

More information

S200-P Series Centrifugal Fire Pumps Operation and Maintenance Instructions

S200-P Series Centrifugal Fire Pumps Operation and Maintenance Instructions S200-P Series Centrifugal Fire Pumps Operation and Maintenance Instructions Table of Contents Read through the safety information and operating instructions carefully before using your S200-P Series Fire

More information

Table of Contents Illustrations

Table of Contents Illustrations Principals of Operation Inspection & Troubleshooting Principles of Operation Inspection & Troubleshooting Form No. F 1031 Section 1000 Issue Date 09/19/94 Rev. Date 02/07/07 Table of Contents Illustrations

More information

HORRY COUNTY FIRE / RESCUE DEPARTMENT PROUD * PREPARED * PROFESSIONAL STANDARD OPERATING PROCEDURE SOP 715 HYDRANT AND WATER POINT INSPECTIONS

HORRY COUNTY FIRE / RESCUE DEPARTMENT PROUD * PREPARED * PROFESSIONAL STANDARD OPERATING PROCEDURE SOP 715 HYDRANT AND WATER POINT INSPECTIONS HORRY COUNTY FIRE / RESCUE DEPARTMENT PROUD * PREPARED * PROFESSIONAL STANDARD OPERATING PROCEDURE APPROVED BY GARRY B. ALDERMAN, FIRE CHIEF: DATE: SOP 715 HYDRANT AND WATER POINT INSPECTIONS PURPOSE OF

More information

TRAINING BULLETIN APPARATUS P-2 January 22, 1998 FLOWMETERS

TRAINING BULLETIN APPARATUS P-2 January 22, 1998 FLOWMETERS TRAINING BULLETIN APPARATUS P-2 January 22, 1998 FLOWMETERS 1. INTRODUCTION 1.1 The intention of this bulletin is to describe the operation and calibration of the SPAN FLOWMINDER, the flowmeter presently

More information

Fire Apparatus Driver/Operator Professional Qualifications Mobile Water Supply Apparatus. Skill Station Menu NFPA 1002 Chapters 4 & 10 (2009 Edition)

Fire Apparatus Driver/Operator Professional Qualifications Mobile Water Supply Apparatus. Skill Station Menu NFPA 1002 Chapters 4 & 10 (2009 Edition) Fire Apparatus Driver/Operator Professional Qualifications Mobile Water Supply Apparatus Skill Station Menu NFPA 1002 Chapters 4 & 10 (2009 Edition) A Preventive Maintenance Mandatory Station B Apparatus

More information

Rural Water Supply Operations Seminar & Drill

Rural Water Supply Operations Seminar & Drill Seneca County, New York Rural Water Supply Operations Seminar & Drill Tanker Shuttle Drill April 5, 2009 Summary Report Overview In April of 2009, the Seneca County, New York, Office of Emergency Services

More information

Fire Department Access & Water Supply

Fire Department Access & Water Supply ROSEBURG FIRE DEPARTMENT FIRE PREVENTION DIVISION fireprevention@cityofroseburg.org 700 SE Douglas Avenue Roseburg, OR 97470 Phone (541) 492-6770 Fire Department Access & Water Supply This brochure is

More information

HL Series Centrifugal Fire Pumps Operation and Maintenance Instructions

HL Series Centrifugal Fire Pumps Operation and Maintenance Instructions HL Series Centrifugal Fire Pumps Operation and Maintenance Instructions Table of Contents Read through the safety information and operating instructions carefully before using your Waterous HL Series Fire

More information

Driver/Operator - Mobile Water Supply

Driver/Operator - Mobile Water Supply CDC 10028W Driver/Operator - Mobile Water Supply Performance Test Extension Course Program (A4L) Air University Air Education and Training Command Acknowledgement Preparation of this volume was aided through

More information

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax: National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: FROM: NFPA Technical Committee on Fire Fighter

More information

Essentials of Fire Fighting

Essentials of Fire Fighting Essentials of Fire Fighting 6 th Edition Certified Volunteer Firefighter Chapter 16 Fire Streams Learning Objectives Explain the way vaporization and steam relate to the extinguishing properties of water.

More information

A Dry Hydrant Success Story. How one county maximizes its dry hydrant output

A Dry Hydrant Success Story. How one county maximizes its dry hydrant output Slide 1 Rural Fire Command by Larry Davis Issue #35 November 2005 A Dry Hydrant Success Story How one county maximizes its dry hydrant output 1 Slide 2 Training America s Rural Fire & Emergency Responders

More information

AMERICAN AVK COMPANY AVK SERIES 24 - HIGH PRESSURE, WET BARREL HYDRANT FIELD MAINTENANCE AND INSTRUCTION MANUAL TABLE OF CONTENTS

AMERICAN AVK COMPANY AVK SERIES 24 - HIGH PRESSURE, WET BARREL HYDRANT FIELD MAINTENANCE AND INSTRUCTION MANUAL TABLE OF CONTENTS AMERICAN AVK COMPANY AVK SERIES 24 - HIGH PRESSURE, WET BARREL HYDRANT FIELD MAINTENANCE AND INSTRUCTION MANUAL TABLE OF CONTENTS EXPLODED ASSEMBLY / PARTS LIST INTRODUCTION / DESCRIPTION RECEIVING AND

More information

Data Sheet Issue A

Data Sheet Issue A General Description The Rapidrop Fig 601/602 dry barrel post / flushing fire hydrant is designed to be a trouble free, easy to maintain hydrant. The Fig 601/602 fire hydrant is rated for a working pressure

More information

According to AWWA-standard

According to AWWA-standard According to -standard Water Fire fighting - UL/FM 304 Gate valves - Cast iron 320 Gate valves OS&Y 306 Service connection valves 322 Post indicators 306 Combi valves 307 Gate valves - 310 Gate valves

More information

San Antonio Water System Standard Specifications for Construction ITEM NO. 834 FIRE HYDRANTS

San Antonio Water System Standard Specifications for Construction ITEM NO. 834 FIRE HYDRANTS San Antonio Water System Standard Specifications for Construction ITEM NO. 834 FIRE HYDRANTS 834.1 DESCRIPTION: This item shall consist of fire hydrant installations using joint restraints in accordance

More information

Is Your Fire Department Efficient?

Is Your Fire Department Efficient? Is Your Fire Department Efficient? Presenter Background: Charles Clark -Colerain Twp. Clerk/Fiscal Officer 1996-2016 -Government Teacher at Pickaway-Ross Career and Technology Center 1975-2009 -Member

More information

Water Transfer. Performance

Water Transfer. Performance Water Transfer Flow Devices Performance Testing Conducted by the Belmont county tanker task force March 20. 2016 Contents: Scope of Testing Test Site Draft Engine Used Test Gauge Suction Hose used for

More information

THE CO$T OF DOING BU$INE$$

THE CO$T OF DOING BU$INE$$ MOTOR VEHICLE COLLISION (Vehicle Rescue) MOTOR VEHICLE COLLISION (Vehicle Rescue) 2 Engines (> 6 personnel) $550,000/engine 1 Heavy Squad (> 1 person) $600,000/squad > 1 Ambulance (>2 personnel) $200,000/ambulance

More information

San Antonio Water System Standard Specifications for Construction ITEM NO. 834 FIRE HYDRANTS

San Antonio Water System Standard Specifications for Construction ITEM NO. 834 FIRE HYDRANTS San Antonio Water System Standard Specifications for Construction ITEM NO. 834 FIRE HYDRANTS 834.1 DESCRIPTION: This item shall consist of fire hydrant installations using joint restraints in accordance

More information

June Drill of the Month Instructor Guide. Topic: Review of Hydraulics and Pump Components

June Drill of the Month Instructor Guide. Topic: Review of Hydraulics and Pump Components Course: Pumps Refresher Course Session Reference: 1 June Drill of the Month Instructor Guide Topic: Review of Hydraulics and Pump Components Level of Instruction: Time Required: 3 hours Materials: Chalkboard

More information

County of Yuba Ordinance Requirements for Rural Fire Protection

County of Yuba Ordinance Requirements for Rural Fire Protection COUNTY OF YUBA FIRE PROTECTION PLANNER!"!! County of Yuba Ordinance Requirements for Rural Fire Protection These regulations have been prepared for the purpose of establishing minimum wildfire protection

More information

Operation and Maintenance. S100 Series Centrifugal Fire Pumps. Table of Contents. Visit us at F /22/02 6/21/18

Operation and Maintenance. S100 Series Centrifugal Fire Pumps. Table of Contents. Visit us at   F /22/02 6/21/18 S100 Series Centrifugal Fire Pumps Operation and Maintenance Form No. F-1031 Section 2117 Issue Date 02/22/02 Rev. Date 6/21/18 Table of Contents Safety Information-----------------------------------------------

More information

Installation. Installation. 12. System Diagram... 10

Installation. Installation. 12. System Diagram... 10 Pressure Control Systems Installation Instructions Form No. F-1031 Section 3010 Issue Date 08/20/96 Rev. Date 9/11/17 Table of Contents Discharge Relief Valve System System Description....................................

More information

INSTRUCTOR GUIDE TOPIC: APPARATUS RESPONSE LEVEL OF INSTRUCTION: TIME REQUIRED: TWO HOURS MATERIALS: APPROPRIATE AUDIO-VISUAL MATERIALS

INSTRUCTOR GUIDE TOPIC: APPARATUS RESPONSE LEVEL OF INSTRUCTION: TIME REQUIRED: TWO HOURS MATERIALS: APPROPRIATE AUDIO-VISUAL MATERIALS TOPIC: APPARATUS RESPONSE LEVEL OF INSTRUCTION: TIME REQUIRED: TWO HOURS INSTRUCTOR GUIDE MATERIALS: APPROPRIATE AUDIO-VISUAL MATERIALS REFERENCES: Fire Department Safety Officer, 1st ed., International

More information

American Flow control 5 1/4 b-84-b-5

American Flow control 5 1/4 b-84-b-5 American Flow control 5 1/4 b-84-b-5 Fire Hydrant FLOW CONTROL Construction Fully complies with AWWA C502 and is available UL Listed and FM Approved in applicable configurations. one-piece bronze OPERATING

More information

COMMONWEALTH OF KENTUCKY COMMISSION ON FIRE PROTECTION PERSONNEL STANDARDS AND EDUCATION DO-MOBILE WATER SUPPLY COMPETENCY EVALUATION

COMMONWEALTH OF KENTUCKY COMMISSION ON FIRE PROTECTION PERSONNEL STANDARDS AND EDUCATION DO-MOBILE WATER SUPPLY COMPETENCY EVALUATION COMMONWEALTH OF KENTUCKY COMMISSION ON FIRE PROTECTION PERSONNEL STANDARDS AND EDUCATION DO-MOBILE WATER SUPPLY COMPETENCY EVALUATION JPR Task: Perform and Document Inspections and Servicing Functions

More information

Relay Pumping Operations

Relay Pumping Operations Relay Pumping Operations OBJECTIVES Identify potential water sources Demonstrate acquiring water from various water sources Demonstrate proper relay pumping hydraulic calculations Demonstrate proper relay

More information

Suction Elbow Flow Performance Tests

Suction Elbow Flow Performance Tests Suction Elbow Flow Performance Tests Conducted by: GBW Associates, LLC And Water Supply Innovations, LLC Hunterdon County, New Jersey 2017 GBW Associates, LLC, Westminster, MD Contents Scope of Project

More information

Measure South Lane County Fire & Rescue General Obligation Bond November 3, 2015

Measure South Lane County Fire & Rescue General Obligation Bond November 3, 2015 Measure 20-237 South Lane County Fire & Rescue General Obligation Bond November 3, 2015 Measure 20-237 Impacts Measure 20-237 is for 5.5 years, funding needed fire apparatus Measure 20-237 is projected

More information

Table of Contents. Acknowledgments... xii Introduction... 1

Table of Contents. Acknowledgments... xii Introduction... 1 Table of Contents Acknowledgments... xii Introduction... 1 1 Types of Apparatus Equipped with a Pump... 10 Case History... 13 Fire Department Pumpers... 13 Common Pumper Requirements and Equipment... 14

More information

AMERICAN FLOW CONTROL 5 1/4 B-84-B-5 FIRE HYDRANT

AMERICAN FLOW CONTROL 5 1/4 B-84-B-5 FIRE HYDRANT AMERICAN FLOW CONTROL 5 1/4 B-84-B-5 FIRE HYDRANT CONSTRUCTION Fully complies with ANSI/AWWA C502 and is available Listed by Underwriters Laboratories, Inc. and Approved by FM Approvals in applicable configurations.

More information

American Flow control 5 1/4 B-62-B-5

American Flow control 5 1/4 B-62-B-5 American Flow control 5 1/4 B-62-B-5 Fire Hydrant FLOW CONTROL Construction Fully complies with AWWA C502 and is available UL Listed and FM Approved in applicable configurations. one-piece bronze OPERATING

More information

Oconee County Emergency Services Westminster, South Carolina

Oconee County Emergency Services Westminster, South Carolina Oconee County Emergency Services Westminster, South Carolina Rural Water Supply Opera:ons Seminar 2-hr Water Supply Drill March 11, 2018 Summary Report The Purpose The purpose of the seminar and drill

More information

Big Water Rigs Rescue Engine 703 Rockville VFD Rockville, MD 2008, GBW Associates, LLC Westminster, Maryland

Big Water Rigs Rescue Engine 703 Rockville VFD Rockville, MD 2008, GBW Associates, LLC Westminster, Maryland www.gotbigwater.com Big Water Rigs Rescue Engine 703 Rockville VFD Rockville, MD Facts & Figures The Rockville Volunteer Fire Department presently operates a pumper known as Rescue Engine 703. Besides

More information

TABLE OF CONTENTS. 3 Outlet Stainless Steel Body. 3 Outlet Ductile Body. 2 Outlet Ductile Body 2 Outlet Bronze Body

TABLE OF CONTENTS. 3 Outlet Stainless Steel Body. 3 Outlet Ductile Body. 2 Outlet Ductile Body 2 Outlet Bronze Body AVK SERIES 24 - HIGH PRESSURE, WET BARREL HYDRANT FIELD MAINTENANCE AND INSTRUCTION MANUAL TABLE OF CONTENTS EXPLODED ASSEMBLY / PARTS LIST INTRODUCTION / DESCRIPTION RECEIVING AND STORAGE INSTALLATION

More information

Standard Operating Procedure Ottawa Fire Service. Extrication Vehicle Extrication Procedures - Revised

Standard Operating Procedure Ottawa Fire Service. Extrication Vehicle Extrication Procedures - Revised Classification P SP 02.1-2002 Special and Technical Operations - Extrication Vehicle Extrication Procedures - Revised Subject Authority Policy Fire Chief s (OFS) shall respond specially trained and equipped

More information

PHILADELPHIA FIRE DEPARTMENT WATER SUPPLY PFD TRAINING MANUAL SUPPLEMENT ENGINE PRACTICES SUPPLEMENT 100 PAGE 1

PHILADELPHIA FIRE DEPARTMENT WATER SUPPLY PFD TRAINING MANUAL SUPPLEMENT ENGINE PRACTICES SUPPLEMENT 100 PAGE 1 PHILADELPHIA FIRE DEPARTMENT WATER SUPPLY PFD TRAINING MANUAL SUPPLEMENT ENGINE PRACTICES SUPPLEMENT 100 PAGE 1 SUPPLEMENT 100 100. WATER SUPPLY Two separate water systems, the domestic and the high pressure,

More information

West Metro Fire Protection District

West Metro Fire Protection District West Metro Fire Protection District Developing Firefighter Instructions The following is an outline of what you are to achieve in relation to a Brush Truck (Type 6). You may or may not be assigned to a

More information

Day 4 March 17, Multiple Choice Identify the choice that best completes the statement or answers the question.

Day 4 March 17, Multiple Choice Identify the choice that best completes the statement or answers the question. Day 4 March 17, 2018 Multiple Choice Identify the choice that best completes the statement or answers the question. 1. Portable fire extinguishers should be chosen based on the: A. heat of the fire. B.

More information

Bulloch County Fire Department Bulloch County, Georgia. Rural Water Supply Opera;ons Seminar 2- hr Water Supply Drill November 6, 2011 Summary Report

Bulloch County Fire Department Bulloch County, Georgia. Rural Water Supply Opera;ons Seminar 2- hr Water Supply Drill November 6, 2011 Summary Report Bulloch County Fire Department Bulloch County, Georgia Rural Water Supply Opera;ons Seminar 2- hr Water Supply Drill November 6, 2011 Summary Report The Purpose The purpose of the seminar and drill was

More information

ABL FIRE PROTECTION 300 HOKE STREET RALEIGH, NC

ABL FIRE PROTECTION 300 HOKE STREET RALEIGH, NC ABL FIRE PROTECTION 300 HOKE STREET RALEIGH, NC 919-835-2225 Job Name : Building : TOWER Location : 4501 CREEDMOOR DR RALEIGH NORTH CAROLINA System : 18TH-2 FLR Contract : Data File : SOLEIL 18-2TH.WXF

More information

Fire Pump Systems. For the protection of life and property, A-C Fire Pump offers package systems that meet every fire protection need.

Fire Pump Systems. For the protection of life and property, A-C Fire Pump offers package systems that meet every fire protection need. Fire Pump Systems For the protection of life and property, A-C Fire Pump offers package systems that meet every fire protection need. 2C11829 A-C Fire Pump Systems and Professional Fire Protection... A

More information

GENERAL FEATURES / SPEC M&H AWWA C502 FIRE HYDRANTS Style 929 Traffic Model 250 PSI Working Pressure 500 PSI Hydrostatic Test AWWA UL / FM Approval Type: Compression type, opening against line pressure.

More information

Application & Reference Data Typical Specifications. Section 914 Vertical Turbine Fire Pump

Application & Reference Data Typical Specifications. Section 914 Vertical Turbine Fire Pump Section 914 Page 101 Supersedes Section 913 Page 101 Dated November 1, 199p Application & Reference Data Typical Specifications Section 914 Section 914 Page 102 Supersedes Section 913 Page 102 Dated November

More information

Pump Service Testing

Pump Service Testing Pump Service Testing SCOPE This guideline shall apply to all members of the Stoney Point Fire Department (SPFD) and shall be adhered to by all members responsible for conducting pump service testing. PURPOSE

More information

Front Suction Flow Test

Front Suction Flow Test www.gotbigwater.com Front Suction Flow Test Evaluating Front Suction Flow Capacity Seneca County, New York April 5, 2009 Overview On April 4 th and 5 th, 2009, the Seneca County, New York, Office of Emergency

More information

FIRE PROTECTION PRODUCTS

FIRE PROTECTION PRODUCTS SUPER CENTURION FIRE HYDRANT Mueller Super Centurion Fire Hydrant Since its introduction in 1976, millions of Centurion fire hydrants have been installed throughout North America. There are a number of

More information

SECTION (15444) - DOMESTIC WATER PACKAGED BOOSTER PUMPS

SECTION (15444) - DOMESTIC WATER PACKAGED BOOSTER PUMPS SECTION 22 11 23.13 (15444) - DOMESTIC WATER PACKAGED BOOSTER PUMPS PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Packaged Domestic Water Booster Pumps B. Related Sections: 1.02 REFERENCES 1. Section

More information

Electric Submersible Pumps

Electric Submersible Pumps Electric Submersible Pumps Versatile pumps with a wide variety of applications Construction Starts Here www.multiquip.com Electric Submersible Pumps Bolt-on discharge port allows easy replacement Cast

More information

High Rise Fire Pumps CM/CGV Series, CMU/CGV Series. Operation and Maintenance

High Rise Fire Pumps CM/CGV Series, CMU/CGV Series. Operation and Maintenance High Rise Fire Pumps CM/CGV Series, CMU/CGV Series Operation and Maintenance Form No. F-1031 Section 2110 Issue Date 10/92 Rev. Date 3/21/17 Table of Contents Safety Information... 1, 2 Introduction...

More information

Operation and Maintenance. CG Series Centrifugal Fire Pumps. Illustrations

Operation and Maintenance. CG Series Centrifugal Fire Pumps. Illustrations CG Series Centrifugal Fire Pumps Operation and Maintenance Form No. F 1031 Section 2102.2 Issue Date 04/28/95 Rev. Date 3/20/17 Illustrations IL 1932 1. CGVG Series Pump... 4 2. CGR Series Pump........................

More information

Fire Engine Information

Fire Engine Information Fire Engine Information City of Thornton Fire Engine 71 2001 American La France This engine was built entirely by Freightliner/American La France. The National Fire Protection Association (NFPA) and Insurance

More information

Background. Vehicle Specifications

Background. Vehicle Specifications Discharge Flow Test Results: Pleasant Valley Community Fire Company - Special Unit 6 Prepared by Mark E. Davis, CFPS, GBW Associates, LLC August 8, 2006 Background Special Unit 6 is a water supply pumper

More information

FUEL DISPENSING SYSTEMS SE-27. Component Details. 12V DC - 15 GPM Metered Tank-top Dispensing System

FUEL DISPENSING SYSTEMS SE-27. Component Details. 12V DC - 15 GPM Metered Tank-top Dispensing System FUEL DISPENSING SYSTEMS Component Details SE-27 12V DC - 15 GPM Metered Tank-top Dispensing System 12V DC Electric Pump - 1 Inlet - 3/4 Outlet 3-Wheel Mechanical Meter 1 Automatic Nozzle, Swivel & Hose

More information

HIGH VELOCITY PUMP PUMP END

HIGH VELOCITY PUMP PUMP END HIGH VELOCITY PUMP USFP pumps are designed for firefighting and high volume water supply in industrial, oil and gas, nuclear, municipal, and marine applications. The USFP High Velocity Pump is designed

More information

LAWN SPRINKLER, IRRIGATION PUMP

LAWN SPRINKLER, IRRIGATION PUMP LAWN SPRINKLER, IRRIGATION PUMP MODEL #, SP0P, SP5P, SP20P, EL0P, EL5P, EL20P SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble, operate or install the product.

More information

CLOW CANADA - M-67 HERITAGE BRIGADIER FIRE HYDRANT SPECIFICATION

CLOW CANADA - M-67 HERITAGE BRIGADIER FIRE HYDRANT SPECIFICATION CLOW CANADA - M-67 HERITAGE BRIGADIER FIRE HYDRANT SPECIFICATION TESTING AND DESIGN SPECIFICATIONS (PER AWWA C502 / NSF /ULC & FM) 1. Hydrant shall be manufactured in accordance with AWWA C502 latest revision

More information

Figs. 800 Verticle, 800 W. Fig. 800 Vertical Type Fig. 800 W. Wall type.

Figs. 800 Verticle, 800 W. Fig. 800 Vertical Type Fig. 800 W. Wall type. Indicator Posts Indicator posts are controls, extending aboveground, for operating underground sprinkler system valves. As an important feature of their design, a target or indicator, visible through an

More information

September 2012 / M&H C502 / Model 129

September 2012 / M&H C502 / Model 129 GENERAL FEATURES / GENERAL SPEC M&H AWWA C502 FIRE HYDRANTS Model 129 Traffic Model 250 PSI Working Pressure 500 PSI Hydrostatic Test AWWA UL / FM Approved Type: Compression type, opening against line

More information

FIREFLO - MODEL F-06 INSPECTION, INSTALLATION & MAINTENANCE MANUAL. Item No.s/Description

FIREFLO - MODEL F-06 INSPECTION, INSTALLATION & MAINTENANCE MANUAL. Item No.s/Description FIREFLO - MODEL F-06 INSPECTION, INSTALLATION & MAINTENANCE MANUAL Item No.s/Description Item No. Description Material Specification HYDRANT Qty. Req d Item No. Description Material Specification 1 Operating

More information

AMERICAN FLOW CONTROL 4 3/4 WATEROUS TREND FIRE HYDRANT

AMERICAN FLOW CONTROL 4 3/4 WATEROUS TREND FIRE HYDRANT AMERICAN FLOW CONTROL 4 3/4 WATEROUS TREND FIRE HYDRANT CONSTRUCTION Fully complies with ANSI/AWWA C502 and is available Listed by Underwriters Laboratories Inc. and Approved by FM Approvals in applicable

More information

ELECTRIC POLICY INTRODUCTION CHAPTER I GENERAL

ELECTRIC POLICY INTRODUCTION CHAPTER I GENERAL INTRODUCTION This policy has been adopted by the Board of Public Works as a guide to obtaining electric service and to set forth the services available, conditions for service, and standards for materials

More information

Pressure Distribution. Western Canada Onsite Wastewater Management Association

Pressure Distribution. Western Canada Onsite Wastewater Management Association Pressure Distribution EFFLUENT DISTRIBUTION Get even distribution Space the doses Layout the distribution system Make choices for: piping, orifices, volumes Use worksheets for calculations Dose or flush

More information

Tanker Off-Load Test: 5,000 gallon Tanker with a 500 gpm Pump

Tanker Off-Load Test: 5,000 gallon Tanker with a 500 gpm Pump Tanker Off-Load Test: 5,000 gallon Tanker with a 500 gpm Pump Granby Fire Department Granby, Massachusetts The Tanker Granby FD s Tanker 1 is a 5,000-gallon tanker that is outfitted with an 8-inch rear

More information

Sentinel 250 Fire Hydrant. Solid design and features to meet any municipal requirement.

Sentinel 250 Fire Hydrant. Solid design and features to meet any municipal requirement. Sentinel 250 Fire Hydrant Solid design and features to meet any municipal requirement. Product Features That meet any municipal requirement. 1 Operating Nut Shields the hold down nut from tampering and

More information

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Engine Module Page 1 of 5 Sprinkler System Controls Revised

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Engine Module Page 1 of 5 Sprinkler System Controls Revised Engine Module Page 1 of 5 SPRINKLER SYSTEM CONTROLS Control and Operating Valves Integral to each sprinkler system is the main control valve. These valves are used to shut off the supply of water when

More information

SECTION FIRE HYDRANTS WITH HYDRANT LOCKS

SECTION FIRE HYDRANTS WITH HYDRANT LOCKS SECTION 33 12 19 FIRE HYDRANTS WITH HYDRANT LOCKS PART 1: GENERAL 1.01 SCOPE A. Fire hydrants. B. Adjustment of fire hydrants and gate valves. 1.02 SUBMITTALS A. Conform to requirements of Section 01 33

More information

Maxi-Pump. High capacity centrifugal pump. GEA Farm Technologies - The right choice. GEA Farm Technologies. GEA Farm Equipment Houle

Maxi-Pump. High capacity centrifugal pump. GEA Farm Technologies - The right choice. GEA Farm Technologies. GEA Farm Equipment Houle GEA Farm Technologies Maxi-Pump High capacity centrifugal pump GEA Farm Equipment Houle GEA Farm Technologies - The right choice. Maxi-Pump and side mount agitator kit 2 GEA Farm Technologies Advantages

More information

REQUEST FOR PROPOSALS FIRE HYDRANT MAINTENANCE SERVICES

REQUEST FOR PROPOSALS FIRE HYDRANT MAINTENANCE SERVICES REQUEST FOR PROPOSALS FIRE HYDRANT MAINTENANCE SERVICES The City of Abbeville, South Carolina is soliciting sealed proposals for Fire Hydrant Maintenance Services. All proposals must be in writing and

More information

HEAVY-DUTY VALVES. *Limited to Manufacture Defects. Operating Pressure (psi) " Stainless Steel " Polymer

HEAVY-DUTY VALVES. *Limited to Manufacture Defects. Operating Pressure (psi)  Stainless Steel  Polymer AKRON BRASS COMPANY PH. 800.228.1161 (330.264.5678) akronbrass.com Heavy Duty Brass Swing-Out Valves Akron Brass offers a wide variety of apparatus valves to meet the demands of today s fire service. All

More information

Environmental Standard Operating Procedure (ESOP) Originating Office: Natural Resources and Environmental Affairs (NREA) Office

Environmental Standard Operating Procedure (ESOP) Originating Office: Natural Resources and Environmental Affairs (NREA) Office Environmental Standard Operating Procedure (ESOP) Originating Office: Natural Resources and Environmental Affairs (NREA) Office File Name: VER-ESOP Revision: 10 February 2017 Title: Vehicle Refueling (Tactical

More information

Chapter 2. The Vehicle-Tank Metering System

Chapter 2. The Vehicle-Tank Metering System Chapter 2 The Vehicle-Tank Metering System Chapter Objectives Upon completion of this chapter, you should be able to: 1. Describe the vehicle-tank metering system, its uses, and its relation to other liquid-volume

More information

Glendale Fire Department

Glendale Fire Department Glendale Fire Department 1) The Glendale Fire Department has had two fire engines or pumpers since the twenties. 2) The primary issue is the responsibility to provide a safe and effective operation for

More information